WorldWideScience
1

Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation  

Science.gov (United States)

This investigation describes the technique for the detection of the X-ray fluorescent radiation

1972-01-01

2

Identification of oxidation states of ultra-trace elements by radiation detection  

International Nuclear Information System (INIS)

The determination of the oxidation state of ultra-trace elements in the environment, especially in the case of actinides, is of importance in many ways. Speciation techniques using radiation may comprise methods based on the detection of the nuclear and atomic radiations emitted in radioactive decay or methods using external sources of excitation. In the former instance, information can be obtained from the energy and intensity of radiation, but at present the partition method is still the most commonly used, although its reliability is questionable. Excitation with intense laser beams, as is currently being used for trace element analysis in photoacoustic and thermal lensing spectroscopic techniques, could conceivably be applied under suitable conditions to ultra-trace elements with a sensitivity approaching that of the radiochemical methods.

1989-11-01

3

A study of the effects of scattered radiation on radiographic quality and methods of elimination of such radiation  

International Nuclear Information System (INIS)

Many mechanical parts are subjected to stresses and strains that may eventually lead to their failure. In order to prevent the costly delays associated with equipment down-time, many parts have to be tested for weaknesses and defects when machinery is constructed or dismantled for maintenance. These procedures are known as Non-Destructive Testing (NDT) methods. Five types of non-destructive testing methods routinely used are radiographic testing, ultrasonic testing, magnetic particle inspection, liquid penetrant testing and eddy current testing. Out of these five techniques industrial radiography plays an important role in non-destructive testing to reveal interior defects in materials. In radiography almost two-thirds of the radiation reaching the film is scattered radiation which does not form the image of defects. Scattered radiation generated inside and outside a material has a very large effect on ...

1998-02-01

4

3. Physical foundations and methodology of radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The physical foundations are described of radionuclide X-ray fluorescence analysis (RXFA) and the table shows the values of K- and L-absorption thresholds and the K- and L-line energies of elements. The calculation of the intensity of characteristic radiation during RXFA proceeds from relations derived for conventional X-ray fluorescence analysis. The choice of the radionuclide source is ruled by the nature of the analysed substance and the used detection technique. The diagram shows the areas of radionuclide sources and the energy of the fluorescence radiation of elements. The table shows the spectra of radionuclide sources suitable for the purposes of RXFA measured by semiconductor Si(Li) and Ge(Li) detectors. (ES).

1983-12-01

5

Nondestructive Detection Techniques of Garter Springs from CANDU Reactors  

Energy Technology Data Exchange (ETDEWEB)

The design and material characteristics of garter spring were summarized and Nondestructive detection techniques of garter spring were also described. In particular, Eddy current testing of loose type garter spring was used in Wolsung unit 1 and was described in detail. The inspection technique of tight type garter spring has not been established and all candidated techniques were investigated in order to choose the possible detection technique. Candidated nondestructive techniques including RFEC, PEC, Magnetic technique using GMR sensor, AE, Guided Wave technique, and high frequency ultrasonic technique, are summarized for evaluating the detectability of tight garter spring.

2004-04-15

6

A study of neutron room scattering at RPCF  

International Nuclear Information System (INIS)

High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National ...

1997-01-05

7

A study of neutron room scattering at RPCF  

Energy Technology Data Exchange (ETDEWEB)

High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National ...

1996-09-01

9

Quantitative measurement of elements in a composite, using multienergy gamma-rays  

International Nuclear Information System (INIS)

This study is an attempt to measure the quantities of elements in a composite by irradiating that composite with #gamma#-rays of various energies and detecting the transmitted radiation through the composite. A previous knowledge of the number of the elements and their attenuation coefficients is required. The quantities are calculated by solving the matrix of a linear system of equations. A computer program was developed to select the best combinations of the available energies. Five criteria were established to determine these energy combinations: (i) the determinant of the attenuation coefficient matrix; (ii) the condition number, (iii) the number of times the solution of the matrix leads to acceptable results; (iv) the indicator, (a new concept); (v) the standard deviations of the results. The intended application of this technique in medicine is to measure the bone mineral content of the skeleton. An examination of the ...

10

An evaluation of planning techniques for stereotactic body radiation therapy in lung tumors  

UK PubMed Central (United Kingdom)

PurposeTo evaluate four planning techniques for stereotactic body radiation therapy (SBRT) in lung tumors.Methods...Full Text Available

2008-04-01

11

Computed radiography. Evaluation of its role in the mass survey for lung cancer: Phantom study  

Energy Technology Data Exchange (ETDEWEB)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in the retrocardiac and subdiaphragmatic regions, respectively. ...

1987-12-01

12

Computed radiography  

International Nuclear Information System (INIS)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in the retrocardiac and subdiaphragmatic regions, respectively. ...

1987-01-01

13

Application of the microbiological method DEFT/APC to detect minimally processed vegetables treated with gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

Marketing of minimally processed vegetables (MPV) are gaining impetus due to its convenience, freshness and apparent health effect. However, minimal processing does not reduce pathogenic microorganisms to safe levels. Food irradiation is used to extend the shelf life and to inactivate food-borne pathogens. In combination with minimal processing it could improve safety and quality of MPV. A microbiological screening method based on the use of direct epifluorescent filter technique (DEFT) and aerobic plate count (APC) has been established for the detection of irradiated foodstuffs. The aim of this study was to evaluate the applicability of this technique in detecting MPV irradiation. Samples from retail markets were irradiated with 0.5 and 1.0 kGy using a {sup 60}Co facility. In general, with a dose increment, DEFT counts remained similar independent of the irradiation while APC counts decreased ...

2009-07-15

14

SENSITIVITY STUDIES FOR AN IN-SITU PARTIAL DEFECT DETECTOR (PDET) IN SPENT FUEL USING MONTE CARLO TECHNIQUES  

Energy Technology Data Exchange (ETDEWEB)

This study presents results from Monte Carlo radiation transport calculations aimed at characterizing a novel methodology being developed to detect partial defects in Pressurized Water Reactor (PWR) spent fuel assemblies (SFAs). The methodology uses a combination of measured neutron and gamma fields inside a spent fuel assembly in an in-situ condition where no movement of the fuel assembly is required. Previous studies performed on single isolated assemblies resulted in a unique base signature that would change when some of the fuel in the assembly is replaced with dummy fuel. These studies indicate that this signature is still valid in the in-situ condition enhancing the prospect of building a practical tool, Partial Defect Detector (PDET), which can be used in the field for partial defect detection.

2008-04-28

16

x - NASA Technical Reports Server  

Science.gov (United States)

Mar 1, 2011 ... Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation ...

17

Application of gamma radiation  

International Nuclear Information System (INIS)

Described and discussed in this paper are radiation processes and their advantages over the conventional techniques. Radiation sterilization of medical products, food irradiation, wood plastic composites, and radiation treatment of sewage and waste waters are presented. The Philippine experience in using these technologies, its problems and barriers are also given. (ELC).

1985-12-10

18

Luminescence characteristics for the detection of radiation treatment of shellfish by using isolated minerals  

International Nuclear Information System (INIS)

Seven types of shellfish were irradiated by gamma ray at doses of 0, 3 and 6 kGy. Pulse photo-stimulated luminescence (PPSL) and thermoluminescence (TL) methods were employed to detect the radiation treatment. The screening of irradiation was carried out by the PPSL method followed by identification using the TL technique. Most of the irradiated shellfish were screened out correctly and only a few showed photon counts a bit higher than the lower threshold value by much lower than the upper threshold value. The TL method was employed using minerals isolated from all the control and irradiated shellfish samples by density gradient treatment. Three parameters, integrated intensities of first glow curves (TL1), ratios of first to that of second glow curves (TL1/TL2), and the shapes of maxima of first glow curves, were utilized for the identification of gamma ray treatment of shellfish. (author)

19

Feasibility of ultra-low-dose multislice CT colonography for the detection of colorectal lesions: preliminary experience  

Energy Technology Data Exchange (ETDEWEB)

Our objective was to evaluate the feasibility of ultra-low-dose scanning for multislice CT colonography in the detection of colorectal lesions. Twenty-seven patients (14 men, 13 women) with clinical indication for conventional colonoscopy were recruited. Multislice spiral CT (Somatom Plus 4 Volume Zoom, Siemens, Germany) examinations were performed after standard oral colonoscopic preparation and colonic distension with room air. Images were acquired using 2.5-mm collimation, 3.0-mm slice thickness, standard reconstruction kernel, 140 kVp, and 10 mAs. Supine and prone acquisitions were obtained in all patients. Images were analyzed on a workstation by two gastrointestinal radiologists. Conventional colonoscopy was performed on the same day in all patients and represented the standard of reference. Total radiation exposure was also calculated. All colorectal cancers were correctly identified at CT colonography (9 of 9, sensitivity 100%). The CT ...

2003-06-01

20

Validating eddy current array probes for inspecting steam generator tubes  

International Nuclear Information System (INIS)

A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques ...

1997-11-16

21

Validating eddy current array probes for inspecting steam generator tubes  

Energy Technology Data Exchange (ETDEWEB)

A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques ...

1997-07-01

22

Multi-spectral schottky barrier infrared radiation detection array  

Energy Technology Data Exchange (ETDEWEB)

A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.

1983-12-27

23

Multi-spectral schottky barrier infrared radiation detection array  

International Nuclear Information System (INIS)

A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.

24

Single Atom Detection With Optical Cavities  

CERN Document Server

We present a thorough analysis of single atom detection using optical cavities. The large set of parameters that influence the signal-to-noise ratio for cavity detection is considered, with an emphasis on detunings, probe power, cavity finesse and photon detection schemes. Real device operating restrictions for single photon counting modules and standard photodiodes are included in our discussion, with heterodyne detection emerging as the clearly favourable technique, particularly for detuned detection at high power.

2008-01-01

25

Explosives detection: the problem and prospects  

Energy Technology Data Exchange (ETDEWEB)

The history of explosives vapor detection includes almost every detection strategy known to man. Initial attempts to utilize these techniques were dismal failures. However, with the development of the Electron Capture Detector (ECD), the first promising detection of explosives vapors became possible. The present commercial explosives detectors detect the higher vapor pressure materials but not the whole spectrum. This paper describes the basic properties of explosives molecules and our research to utilize these properties for increased detection sensitivity.

1984-01-01

26

Radiation-induced damage to DNA; Les lesions radio-induites de l'ADN  

Energy Technology Data Exchange (ETDEWEB)

This short survey focuses on the main radiation-induced base lesions that have been identified within cellular DNA. For this purpose, sensitive assays that are aimed at measuring a few modifications per 10{sup 7} normal bases were set-up. In that respect high performance liquid chromatography - tandem mass spectrometry (CLHP-MS/MS) was found to be able to single out the formation of 9 oxidized nucleosides and two modified nucleo-bases out of the 70 oxidative base lesions that have been identified in model systems. As a striking result, it was found that in the DNA of {gamma}-irradiated human monocytes, the formamide-pyrimidine derivative of guanine is produced in a higher yield than the ubiquitous 8-oxo-7,8-dihydro-guanine damage, both arising from the same radical precursor. However, relatively high doses of ionizing radiation (> 20 Gy) have to be applied in order to detect an increase in the level of the damage. ...

2002-03-01

27

Partitioning Tracers for In-Situ Measurement of Nonaqueous Phase Liquids in the Subsurface - Final Report - 09/15/1996 - 09/14/2000  

Energy Technology Data Exchange (ETDEWEB)

The overall goal of the proposed project is to explore the use of partitioning tracers to characterize dense nonaqueous phase liquids (DNAPLs) in aquifer systems. Bulk-phase partitioning tracers will be investigated to detect and determine DNAPL saturation, while interface partitioning tracers will be investigated to measure the area of the DNAPL-water interface. The specific objectives that will be addressed to accomplish this goal are: (1) Investigate the use of partitioning tracers to detect and determine both the saturation and interfacial area of DNAPLs in saturated porous media. (2) Investigate the effect of rate-limited mass transfer on the transport behavior of partitioning tracers. (3) Investigate the effect of porous-media heterogeneity on the transport behavior of partitioning tracers. (4) Develop and evaluate mathematical models capable of simulating the transport of partitioning tracers in complex systems. This proposal outlines an ...

2000-09-14

28

Relationship of Optical Coating on Thermal Radiation ...  

Science.gov (United States)

drical Enclosures Using a Numerical Ray Tracing Technique. NASA. TM-I02527, 1990 . Buckley, H.: Radiation from the Interior of a Reflecting Cylinder. Philos. ...

29

Recent developments and applications for the University of Texas thermal neutron imaging facility  

Energy Technology Data Exchange (ETDEWEB)

The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system resolution have hot been determined. The TNIF is currently being revamped to begin work with the ...

2001-07-01

30

Infrared radiation features of coal and rocks under loading  

Energy Technology Data Exchange (ETDEWEB)

Samples of fat coal-E, its roof sandstone-A and blind coal-W from two coal mines in Hebei Province of China were brought to the laboratory to study the features of infrared thermal images and radiation temperature in the course of uni-axial load and uni-axial cycle load. To check the results of infrared remote sensing detection, two other methods, acoustic emission detection and electrical resistance detection were also used. The AGA-782 thermalvision detected change of the temperature field of the samples` surfaces. The study showed that: (1) coal rocks and sandstone in the course of loading have three types of infrared thermal image features and three types of infrared radiation temperature features; (2) infrared detection is comparable with acoustic emission detection and electrical resistance ...

1998-10-01

31

Theoretical considerations for X-ray phase contrast mammography by Thomson source  

Energy Technology Data Exchange (ETDEWEB)

The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase imaging with respect to standard absorption imaging, in the ...

2009-09-01

32

Immunohistochemical detection of epidermal growth factor receptor in radiation-induced lung tumors in Beagle dogs  

International Nuclear Information System (INIS)

Increased levels of epidermal growth factor receptor have been reported in a variety of tumors, including pulmonary squamous cell carcinomas in man. The purpose of this study was to determine if increased levels of epidermal growth factor (EGFR) were present in lung tumors from Beagle dogs that had been exposed to "2"3"9PuO_2- Using immunohistochemical techniques, sections from 17 lung tumors were examined for the presence of EGFR. Seven of the tumors were strongly positive for EGFR; the remainder of the tumors and the normal lung sections were negative. The positive immunostaining could not be correlated with the histologic phenotype of the tumors. Work is in progress to determine the level of EGFR in preneoplastic, proliferative epithelial foci in the Iung. (author)

1988-12-01

33

Radiation dose in computerized tomography  

International Nuclear Information System (INIS)

Dosimetric studies in 80 patients examined with the tomographic device 'Somatom' are reported. The gonad doses are compared to those of conventional radiographic techniques.

34

Intraband Absorptoin of Far-Infrared Light by Electrons in ...  

Science.gov (United States)

... significant change of spontaneous radiation intensity. It is very sensitive technique allowing the observation of small changes of light absorption. ...

1999-06-18

35

The influence of scattered radiation on recording systems and quality-assurance test parameters  

International Nuclear Information System (INIS)

Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).

1988-02-23

36

The influence of scattered radiation on recording systems and quality-assurance test parameters  

International Nuclear Information System (INIS)

Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).

37

ESR dosimetry of irradiated chicken legs and chicken eggs  

Energy Technology Data Exchange (ETDEWEB)

Ionising radiation induces stable free radicals in chicken bones and in the shell of chicken eggs which can be detected, by the electrons spin resonance (ESR) technique, well beyond the shelf-life of the food and can be used for dosimetry. The method usually adopted to evaluate ``a posteriori`` the dose given during the ionising radiation treatment of food, is the dose additive method. To assess the dose, the ESR signal amplitude of the irradiated food (bone or egg shell in the present case) is measured and then the dose-effect relationship is obtained by re-irradiating the sample with some additive doses (usually of 1 kGy). The dose-effect curve is back-extrapolated and the initial given dose determined. At the Istituto Superiore di Sanita (ISS), Rome, Italy, a research programme was approved two years ago aimed to, (1) study new methodological approaches for ESR dose assessment, and (2) analyse the ...

1996-12-31

38

Optically stimulated luminescence and thermoluminescence in CVD diamond and dosimetric evaluation in fields of ionizing radiation; Luminiscencia opticamente estimulada y termoluminiscencia en diamante DQV y evaluacion dosimetrica en campos de radiacion ionizante  

Energy Technology Data Exchange (ETDEWEB)

The optically stimulated luminescence (OSL) results a highly appropriate dosimetric technique for readings of absorbed radiation 'in alive' and 'in situ', as well as in real time. The CVD diamond on the other hand presents excellent qualities like radiation reader thanks to its reproducibility, radiation resistance, biocompatibility and non toxicity. The present work studies the answer of two diamond films pure and polluted with nitrogen (750 ppm) grown by the Chemical Vapor Deposition method (CVD) on silicon substrate (001) irradiated with beta (Sr-90) in the 0.833-100 Gy interval. The optical stimulation was carried out by 40 seconds with infrared laser (830 nm, 0.36 W/cm{sup 2}) and the filter BG-39 (300-600 nm) coupled the PM. The intensity and the decay of the hyperbolic type of the LOE curves were similar in both samples, for the non doped diamond were observed ...

2006-07-01

39

Theory of edge radiation  

CERN Document Server

We formulate a complete theory of Edge Radiation based on a novel method relying on Fourier Optics techniques. Similar types of radiation like Transition Undulator Radiation are addressed in the framework of the same formalism. Special attention is payed in discussing the validity of approximations upon which the theory is built. Our study makes consistent use of both similarity techniques and comparisons with numerical results from simulation. We discuss both near and far zone. Physical understanding of many asymptotes is discussed. Based on the solution of the field equation with a tensor Green's function technique, we also discuss an analytical model to describe the presence of a vacuum chamber. In particular, explicit calculations for a circular vacuum chamber are reported. Finally, we consider the use of Edge Radiation as a tool for ...

2008-01-01

40

Radiation exposure of the population of the GDR by X-ray diagnostics  

International Nuclear Information System (INIS)

The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.

1986-01-01

41

Use of fission track analysis technique for the determination of MicroBequerel level of "2"3"9Pu in urine samples from radiation workers handling MOX fuel  

International Nuclear Information System (INIS)

Fission track analysis (FTA) technique for the determination of "2"3"9Pu excreted through urine has been standardized using blank samples, tracer and "2"3"9Pu spikes. Double stage anion exchange separation protocol has been applied and an average radiochemical recovery of "2"3"9Pu of 18% was obtained. An average track registration efficiency of 11 tracks per #mu#Bq of "2"3"9Pu, irradiated to 0.35x10"1"7 neutron fluence was established. Reagent blank urine samples from 11 controlled subjects were analyzed by FTA and an average of 149#+-#14 tracks was obtained. Minimum detectable activity of 34 #mu#Bq L"-"1 of urine sample was obtained and will be useful for monitoring chronic exposure cases handling MOX fuel.

2011-07-01

42

INTRINSIC DOSIMETRY: A POTENTIAL NEW TOOL FOR NUCLEAR FORENSICS INVESTIGATIONS  

International Nuclear Information System (INIS)

Thermoluminescence (TL) dosimetry was used to measure dose effects on the raw stock material of borosilicate container glass from different geographical locations. Effects were studied at times up to 60 days post-irradiation at doses from 0.15 to 20 Gy. The minimum detectable dose using this technique was estimated to be 0.15 Gy which is roughly equivalent to a 24 hr irradiation 1 cm from a 50 ng source of 60Co. Two peaks were identified in the TL glow curve, a relatively unstable peak around 125 C and a more stable peak around 225 C. Differences in TL glow curve shape and intensity were also observed for the glasses from different geographical origins. We investigate radiation induced defects in glass to further develop the technique of intrinsic dosimetry - the measurement of the total absorbed dose received by the walls of a container holding radioactive material. Intrinsic dosimetry is intended to ...

2010-07-11

44

Induction and use of sex linked lethal mutations in the pink bollworm  

International Nuclear Information System (INIS)

The sterile insect release technique can often be improved by removal of females before release. Rearing efficiencies can also be increased if removal of the females occurs at early developmental stages. In order to begin to develop genetic sexing strains for the pink bollworm, Pectinophora gossypiella (Saunders), it was necessary to determine the best dosage of radiation for induction of viable sex linked recessive lethal mutations and to see if stocks containing induced sex linked lethals could be maintained in culture. Sex linked recessive lethal mutations can be detected by distorted sex ratios in the progeny of treated adults. However, in the pink bollworm, highly distorted sex ratios are common even in the absence of induced mutations. Therefore, a visible sex linked trait, purple eye, was used as a marker for the untreated X-chromosomes in crosses. Thus, the presence of a recessive sex linked lethal mutation induced ...

1987-11-16

45

Results of the remote sensing feasibility study for the uranium hexafluoride storage cylinder yard program  

Energy Technology Data Exchange (ETDEWEB)

The US DOE manages the safe storage of approximately 650,000 tons of depleted uranium hexafluoride remaining from the Cold War. This slightly radioactive, but chemically active, material is contained in more than 46,000 steel storage cylinders that are located at Oak Ridge, Tennessee; Paducah, Kentucky; and Portsmouth, Ohio. Some of the cylinders are more than 40 years old, and approximately 17,500 are considered problem cylinders because their physical integrity is questionable. These cylinders require an annual visual inspection. The remainder of the 46,000-plus cylinders must be visually inspected every four years. Currently, the cylinder inspection program is extremely labor intensive. Because these inspections are accomplished visually, they may not be effective in the early detection of leaking cylinders. The inspection program requires approximately 12--14 full-time-equivalent (FTE) employees. At the cost of approximately $125K per FTE, this translates to ...

1997-02-01

46

Self-filling and self-purging apparatus for detecting spontaneous radiation from substances in fluids  

Energy Technology Data Exchange (ETDEWEB)

Disclosed herein is a radiation detector providing for the in situ automatic sampling of fluids containing substances emitting radiation, especially Cerenkov radiation. The detector permits sampling within well casings and is self-purging such that no additional provisions must be established for the storage and disposal of contaminated fluids.

1993-01-01

47

Detection of drugs and explosives using neutron computerized tomography and artificial intelligence techniques  

International Nuclear Information System (INIS)

In this study the development of a methodology to detect illicit drugs and plastic explosives is described with the objective of being applied in the realm of public security. For this end, non-destructive assay with neutrons was used and the technique applied was the real time neutron radiography together with computerized tomography. The system is endowed with automatic responses based upon the application of an artificial intelligence technique. In previous tests using real samples, the system proved capable of identifying 97% of the inspected materials.

2010-06-01

48

Electron-beam induced RAFT-graft polymerization of poly(acrylic acid) onto PVDF  

Energy Technology Data Exchange (ETDEWEB)

This paper explores for the first time the post-radiation-induced-graft polymerization on solid substrate using reversible addition-fragmentation transfer (RAFT) mechanism. Radiation-induced graft polymerization onto polymers is a potentially interesting technique to create easily new materials from highly resistant polymers, e.g. surface graft polymerization of acrylic acid (AA) onto poly(vinylidene difluoride) (PVDF) improves its surface properties without losing its excellent mechanical properties. As a consequence of the radical nature of the polymerization processes it is difficult to control molecular weight of grafted chains, and therefore design and standardize the properties of the final product. RAFT polymerization is a suitable method to obtain monodisperse polymers. The ability of the RAFT agents to control the polymer chain length could be an interesting approach to improve the grafted polymers obtained by ...

2005-07-01

49

Theoretical review of techniques for the remote detection of methane in underground coal mines  

Energy Technology Data Exchange (ETDEWEB)

The nature and relationship of methane to coal mines is discussed and sources of information are outlined. Methods of gas analysis in general and methods for the detection of methane in use in coal mines are described. Methods of remote detection of gases and those that have application for use in underground coal mining operations are discussed. The report represents recommendations on remote methane detection systems that may find application in underground coal mines. (20 refs.)

1983-01-01

50

Use of an alkaline phosphatase-labeled synthetic oligonucleotide probe for detection of Campylobacter jejuni and Campylobacter coli.  

UK PubMed Central (United Kingdom)

A commercially available synthetic nucleic acid probe (SNAP) conjugated to alkaline phosphatase was compared with standard culture techniques for detecting Campylobacter species. The SNAP was able to...Full Text Available

1990-07-01

51

Shedding New Light on Early Caries Detection  

UK PubMed Central (United Kingdom)

Dental caries continues to be a common chronic disease among various population groups. Patient care can be improved with detection at the earliest stage. However, current techniques do not...Full Text Available

2008-12-01

52

Processing and microfiltration of mosquitoes for malaria antigen detection in a rapid dot immunobinding assay.  

UK PubMed Central (United Kingdom)

Data on a technique for the detection of antigen from arthropod vectors in a dot immunobinding assay are presented. In this system, antigen present in the vector was first solubilized in sodium dodecyl...Full Text Available

1990-08-01

53

Enzyme amplified immunoassay: a novel technique applied to direct detection of Chlamydia trachomatis in clinical specimens.  

UK PubMed Central (United Kingdom)

Endocervical swabs from 212 women and urethral swabs from 100 men were tested by the routine methods for McCoy cell culture and simultaneously by a novel enzyme amplified immunoassay test to detect...Full Text Available

1985-10-01

54

Detection of rotavirus by serological trapping on antibody-coated electron microscope grids.  

UK PubMed Central (United Kingdom)

A serological trapping technique for detecting rotaviruses is described which involves coating electron microscope grids with protein A and specific rotavirus antiserum. The presence of a layer of antibodies...Full Text Available

1980-07-01

55

Interim explosives detection alternatives  

Energy Technology Data Exchange (ETDEWEB)

There is a general concern with insiders smuggling bomb quantities of explosives into sensitive facilities such as nuclear facilities. At this time, there is no single explosives detection device that is suitable for monitoring personnel and their packages for explosives in an operational facility environment. However, there are techniques combining available commercial technologies with procedures and threat analysis that can significantly increase the insiders risk and reduce the population of adversaries. This paper describes the available applicable explosives detection technologies and discusses the techniques that could be implemented on an interim basis. It is important that these techniques be considered, so that some interim level of security against the explosives threat can be established until more sophisticated equipment that is under development becomes available.

1991-01-01

56

Molecular spectroscopy and planetary atmospheres  

Energy Technology Data Exchange (ETDEWEB)

With the improvements accomplished during the past 15 years in detection techniques and instrumentation and with the opening of space exploration, molecular spectroscopy has become a very efficient way to probe planetary atmospheres.

1984-01-01

57

Radiation treatment of crude drugs. Development of suitable methods of detection. Strahlenbehandlung von Arzneidrogen. Entwicklung geeigneter Nachweismethoden  

Energy Technology Data Exchange (ETDEWEB)

It may be necessary to reduce microbiological contamination of crude drugs (medicinal plants or their parts like roots, leaves, flowers). This can be done by treating the drugs with ionizing radiation. Meethods for detection of such an irradiation were developed. It could be pointed out that measurements of luminescence, viscosity and electron spin resonance were suitable for specific drugs, but not for all drugs. (orig.).

1992-09-01

58

Study on dose distribution of therapeutic proton beams with prompt gamma measurement  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma distribution was compared to the dose distribution measured by an ionization chamber at three different ...

2007-03-15

60

Detection of Free-Living Amoebae in Some Water Sources and its Control by Ultraviolet- Radiation  

International Nuclear Information System (INIS)

Among the numerous free-living amoebae (FLA) of soil and water habitats, certain species belonging to two genera Acanthamoeba and Naegleria are facultative parasites of man.They cause disease called primary amoebic meningoencephalitis where history of contact with water was recorded in most of the cases especially with Naegleria species. The present work aimed to search for presence of free-living amoebae in the water and trials for its control by Ultraviolet-radiation (UV-radiation). Samples from different water sources were examined for the presence of free-living amoebae. These samples were cultured on non-nutrient agar streaked with bacteria. Amoebae were detected and identified by means of their morphological characters. Twelve positive cases of one hundred and twenty examined samples could be detected. The positive samples were exposed to different doses of UV-radiation for ...

61

The influence of stray radiation on image quality  

International Nuclear Information System (INIS)

The present state of knowledge on the influence of stray radiation on image quality and its physical description and quantification is summarized. Experimental results on the influence of physical parameters on the fraction of scattered radiation and the effect of scatter reduction by air gap technique and secondary radiation grids are committed. Open theoretical and practical problems and the limitations of common methods of scatter reduction are pointed out. (author).

62

Annealing behavior of radiation damages in metal-silicides  

International Nuclear Information System (INIS)

The annealing behavior of the radiation damage in epitaxial Pd_2Si and NiSi_2 films on Si, due to the implantation of 100 keV Ar ions, is investigated by using the channeling technique with "4He ions. (U.K.).

63

Neutronic detection device with extended flux range for control of nuclear reactors. Dispositif de detection neutronique a dynamique etendue pour le controle et la commande des reacteurs nucleaires  

Energy Technology Data Exchange (ETDEWEB)

The neutron detector is cased in a metal envelop and has one detector with a very sensitive fission chamber and a second detector with a fission chamber less sensitive that the first one and a boron coated ionisation chamber for reducing gamma radiation detection.

1992-06-12

64

Indirect Dark Matter Detection with Cosmic Antimatter  

CERN Document Server

The indirect detection of particle dark matter (DM) is based on the search for anomalous components in cosmic rays (CRs) due to the annihilation of DM pairs in the galactic halo, on the top of the standard astrophysical production. These additional exotic components are potentially detectable at Earth as spectral distortions for the various cosmic radiations: $\\chi + \\chi \\to q \\bar{q}, W^+ W^-, ... \\to \\bar{p}, \\bar{D}, e^+ \\gamma and \

2010-01-01

65

Medulloblastoma: Are We Overtreating?  

UK PubMed Central (United Kingdom)

Modern advances in the concept and the techniques of megavoltage radiation therapy have revolutionized the treatment of medulloblastoma. Five-year survivals of 50 to 70 percent are achieved by craniospinalaxis...Full Text Available

1985-02-01

66

Molecular-beam/surface-science apparatus for state-resolved chemisorption studies using pulsed-laser preparation  

International Nuclear Information System (INIS)

We describe a new apparatus that combines pulsed laser excitation in a molecular beam with surface-science methods for preparation of clean single-crystal surfaces and detection of adsorbates to enable state-selected studies of gas-surface reaction dynamics. Reactant molecules are prepared in specific vibrationally excited states via overtone pumping using tunable, narrow-band laser radiation. The collision-free environment of the molecular beam prevents relaxation of the prepared molecules before impact on the target surface and enables complete control over the collision energy and incidence angle. Chemisorption products are detected after a given deposition time by Auger electron spectroscopy. To achieve sufficient beam flux of state-selected reactant molecules for product detection by standard surface-science techniques, we use a high-intensity, short-pulse molecular-beam source ...

2003-09-01

67

Use of sting-response techniques for simulate diagnostics in human esophagus; Uso de tecnicas estimulo-respuesta para simular diagnosticos en esofago humano  

Energy Technology Data Exchange (ETDEWEB)

In this work a study of simulation of the gamma graphic studies that are carried out in human esophagus in the Dept. of Nuclear Medicine of the 'Celestino Hernandez Robau Hospital of Santa Clara is presented. For the investigation tubular reactors were used and sting-response techniques with radioactive tracer of Technetium 99 metastable to a concentration of 1 mCi and several flows were applied. The distribution curves of residences times were obtained, those that respond to an equation of the type: Y = A + B exp (- exp((x-C)/D)) - ((x-C/D)+1). They were also carried out, optimizations studies of the doses of the radioactive to give to the patients from 1 mCi (that is the one used in studies) up to 0,5 mCi, and the influences on the obtained distributions of residence time were analyzed. It was confirmed the possibility to lower the doses with clear information of the signal. It was also carried out a simulation of the attenuation of the ...

2003-07-01

68

Investigation of radiation effects of interaction of #beta#"- -radiation with polyvinylchloride  

International Nuclear Information System (INIS)

Dissipation of energy of #beta#"--radiation in polyvinylchloride (PVC) was analyzed. Change of PVC properties at irradiation by beta beams with energy 2,32 MeV was characterized using potentials of inter- and intramolecular interactions as well as Born potential. Correlation between some micro- and macroproperties of PVC was detected and ways of their controlled correction were proposed. (authors)

69

Equipment hardening and hardness assurance  

International Nuclear Information System (INIS)

The introduction of tolerance to radiation (''radiation-hardness'') into large electronic systems is one of the major tasks to which this Handbook will be put. The practices recommended here for inculcating radiation-tolerance in equipment require advanced physical modeling techniques, precise engineering procedures, and firm assurance procedures. The degree to which these procedures should be used in an equipment project can be measured by the severity of the raw radiation environment, the desired reliability of the system, and the requirement of that project for radiation-sensitive technologies. The balance of device/circuit design versus shielding will depend on whether the radiation is highly penetrating -- as in isotope handling or military environments -- or readily attenuated, as in space. In this chapter the authors have attempted to ...

70

Enhanced coherent undulator radiation from bunched electron beams  

International Nuclear Information System (INIS)

When energetic bunches of electrons traverse an undulator field, they can spontaneously emit radiation both coherently and incoherently. Although it has generally been assumed that undulator radiation is incoherent at wavelengths short compared to the longitudinal size of the electron bunch, several recent observations have proved this assumption false. Furthermore, the appearance of coherent radiation is often accompanied by a significant increase in radiated power. Here we report observations of strongly enhanced coherent spontaneous radiation together with direct measurements, using transition radiation techniques, of the electron distributions responsible for the coherent emission. We also report demonstrated enhancements in the predicted spontaneous radiated power by as much as 6x10"4 using electron bunch ...

1995-09-28

71

Polarised foreground removal at low radio frequencies using rotation measure synthesis: Uncovering the signature of hydrogen reionisation  

CERN Document Server

Measurement of redshifted 21-cm emission from neutral hydrogen promises to be the most effective method for studying the reionisation history of hydrogen and, indirectly, the first galaxies. These studies will be limited not by raw sensitivity to the signal, but rather, by bright foreground radiation from Galactic and extragalactic radio sources and the Galactic continuum. In addition, leakage due to gain errors and non-ideal feeds conspire to further contaminate low-frequency radio obsevations. This leakage leads to a portion of the complex linear polarisation signal finding its way into Stokes I, and inhibits the detection of the non-polarised cosmological signal from the epoch of reionisation. In this work, we show that rotation measure synthesis can be used to recover the signature of cosmic hydrogen reionisation in the presence of contamination by polarised foregrounds. To achieve this, we apply the rotation measure synthesis ...

2010-01-01

72

High sensitivity detection and characterization of the chemical state of trace element contamination on silicon wafers  

CERN Document Server

Increasing the speed and complexity of semiconductor integrated circuits requires advanced processes that put extreme constraints on the level of metal contamination allowed on the surfaces of silicon wafers. Such contamination degrades the performance of the ultrathin SiO sub 2 gate dielectrics that form the heart of the individual transistors. Ultimately, reliability and yield are reduced to levels that must be improved before new processes can be put into production. It should be noted that much of this metal contamination occurs during the wet chemical etching and rinsing steps required for the manufacture of integrated circuits and industry is actively developing new processes that have already brought the metal contamination to levels beyond the measurement capabilities of conventional analytical techniques. The measurement of these extremely low contamination levels has required the use of synchrotron radiation total reflection X-ray ...

2003-01-01

73

The main activities and scientific collaboration possibilities at Ankara Nuclear research and training center  

International Nuclear Information System (INIS)

Full text: Founded in 1964, Ankara Nuclear Research and Training Center (ANRTC) conducts and facilitates the scientific activities including training (summer practice, MSc and Ph D studies in physics and chemistry, IAEA fellowship programs etc.), research and other studies in nuclear and related fields. As it's a part of main duties, ANRTC has analysis on the variety of samples, and radiation protection services commercially, for radiation workers in state, public and private sectors. Research, development and application projects implemented in this Center have mostly been supported by State Planning Organization (SPO) and Turkish Atomic Energy Authority (TAEA). In addition to the projects there are on going collaborative studies with some national Universities and International Atomic Energy Agency. The main activities carried out in ANRTC can be summarized as: studies on experimental nuclear physics, application of nuclear ...

2004-10-01

74

A Study on TOFD Inspection Using Phased Array Ultrasonic Technique  

Energy Technology Data Exchange (ETDEWEB)

The techniques in order to measure the depth of defect in weldment and structure accurately have been developed. Many researches have made efforts to develop the methods for the accurate depth sizing of defect. TOFD is known as the most accurate method of various methods for measuring depth sizing. However, there is a possibility to miss defects because of the limitation of beam coverage for the ultrasound incident angle. In this study, the results for detectability and depth sizing using phased array ultrasonic technique for thick body were compared with those of conventional TOFD technique. It was experimentally confirmed that the phased array ultrasonic TOFD technique gives good detectability and accurate depth measurement for the various types of defects. The phased array ultrasonic TOFD technique developed in this study will contribute ...

2005-08-15

75

Radiation Isotope Identification Device (RIIDs) Field Test and Evaluation Campaign  

Energy Technology Data Exchange (ETDEWEB)

Handheld, backpack, and mobile sensors are elements of the Global Nuclear Detection System for the interdiction and control of illicit radiological and nuclear materials. They are used by the U.S. Department of Homeland Security (DHS) and other government agencies and organizations in various roles for border protection, law enforcement, and nonproliferation monitoring. In order to systematically document the operational performance of the common commercial off-the-shelf portable radiation detection systems, the DHS Domestic Nuclear Detection Office conducted a test and evaluation campaign conducted at the Nevada Test Site from January 18 to February 27, 2006. Named 'Anole', it was the first test of its kind in terms of technical design and test complexities. The Anole test results offer users information for selecting appropriate mission-specific portable ...

2007-08-01

76

A proposal for prevention of acute radiation hazard and social panic regarding orphan sources in Japan  

International Nuclear Information System (INIS)

To respond to an increase of social problems concerning orphan sources in Japan, a working group was formed in the Japan Health Physics Society. In this working group, we investigated how to prevent acute radiation hazard or social panic regarding orphan sources in scrap metal and detection system for orphan sources brought into scrap yards before recycle. For detection system in a scrap yard we conducted an experiment on detectability of monitoring instrument using a radiation source mixed in scrap metal on a truck. The result showed that it was not easy to detect even a high-level source if it was shielded by scrap metal. We also estimated detection limits for radioactive materials in scrap metal by calculation that was validated with experimental data. We summarized present status about orphan sources in Japan and proposed a ...

2002-10-20

77

Method and system for determining depth distribution of radiation-emitting material located in a source medium and radiation detector system for use therein  

Energy Technology Data Exchange (ETDEWEB)

A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the detector as rays parallel to the detector axis of the detector. The collimator may be a ...

2003-03-04

78

Gravitational waves from the big bang  

Energy Technology Data Exchange (ETDEWEB)

The gravitational radiation produced by the big bang is calculated in order to provide a condition for the unification of the gravitational and electromagnetic forces. By analogy with electromagnetic radiation and under the assumption that gravity is also quantized, it is shown that matter would have decoupled from gravitational radiation at a time of approximately 10 to the -43rd sec and would have dominated it at 10 to the -17th sec. Furthermore, the theory predicts a background gravitational radiation temperature of 0.003 K which peaks at a wavelength of about 1 m, which may be detected by the comparison of the synchronization of clocks at increasing distances.

1980-12-20

79

Further means for reducing radiation dose during exposure of the pelvis in infants  

International Nuclear Information System (INIS)

A simple dose-saving procedure for the diagnosis of congenital hip dysplasia employing a diaphragm in nearfocus position is presented. Doses to the skin and the gonads were measured with a phantom for the new and other techniques. With optimal techniques the skin dose is smaller than 2 mR and the gonadal doses lie around 0.1 mR for both male and female patients. An estimate of the dose burden from undesired radiation is appended. (orig.).

80

Direct dark matter identification with a hybrid detection technique  

CERN Document Server

In the quest to understand the ultimate nature of WIMPs, we propose the use of a hybrid detection technique: cylinders filled with liquefied noble gasses, acting as targets, are immersed inside a tank of Gd-doped ultra-pure water that provides an active and efficient veto against neutrons. The evaluation of the background rejection capabilities and physics potential of this instrument have been carried out through a full GEANT4 simulation, assuming the detector will be located at the Canfranc underground laboratory (in the Spanish Pyrenees). Our results compare very favourably with existing or planned experiments in the field. This technique is scalable and will allow to reach target masses of few tonnes in the next future.

2008-01-01

81

Vacuum ultraviolet radiometry of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two ...

1995-10-01

82

Oil-filled cable surveillance system using newly developed optical fiber gas sensor  

Energy Technology Data Exchange (ETDEWEB)

A new surveillance system for Oil-Filled cable, which can provide continuous monitoring, using a newly developed optical gas sensor that can detect the concentration of the gas dissolved in the oil with extremely high sensitivity has been developed. It was proved that the degree of deterioration of the insulating oil can be detected by measuring C{sub 2}H{sub 2} and CH{sub 4} by investigating the relation between the degree of deterioration and amount of combustible gas generated. In order to detect extremely small amounts of gas, a new gas detecting method using absorption line of the gas using a frequency modulated technique has been developed. The gas detection ability was also confirmed by examination using a 66 kV of cable and the possibility of detection at an early stage is expected.

1996-04-01

83

Fatigue crack detection in aircraft skin structures using eddy current array technique  

International Nuclear Information System (INIS)

Detection of fatigue damage cracks in aircraft skin structures is an ongoing NDT challenge. Cracks growing rate is difficult to predict, and for this reason, it is important to detect them as soon as possible to avoid a catastrophic break. Eddy current methods are known and well-accepted techniques which are relatively simple to carry out. However, with conventional inspection of airframe structures using standard driver-pickup eddy current probes, it is difficult to detect small fatigue cracks initiated in the second layer of the skin and in the shadow region at fastener holes. Such difficulty is related to fasteners length and their spacing which reduces test sensitivity. This report explains the development of improved eddy current probe/technique to detect and visualize fatigue cracks in fasteners. In this study, an eddy current array probe was evaluated and ...

2004-01-01

84

Packaging materials for use in radiation processing of foods  

International Nuclear Information System (INIS)

In radiation processing of food, the product often has to be prepackaged to prevent microbial recontamination during and after irradiation. The packaging material is exposed to radiation during radiation processing and radiation stability is a key consideration in the selection of packaging materials. The effects of ionizing radiation on many food packaging materials at the dose levels recommended for food precessing can be minimized by selecting appropriate radiation resistant materials. It is important to select materials in which chemicals formed as a result of the radiation treatment do not migrate and interact with the food, affecting its organoleptic and toxicological aspects. It is also important to select materials in which the physical properties are not altered to the extent they cannot resist damage during commercial production, ...

85

ETB dosemeter, a passive integrating radon dosemeter combining activated charcoal and TLD  

Energy Technology Data Exchange (ETDEWEB)

A passive integrating radon dosemeter is described. The radon dosemeter is based on radon adsorption on activated charcoal. By placing TLD crystals inside an open charcoal container, the beta radiation from radon daughters, produced by the decay of adsorbed radon, is detected continuously during the exposure time. After closing the container, radiation will still be detected by the TLD crystal. Calibration procedures are reported and the suitability of the dosemeter is discussed. The dosemeter proved to be suitable for measurements during periods from a few days to two weeks both in domestic and mine atmospheres.

1983-01-01

86

The utilization of non-destructive method for in-service inspections in nuclear power components  

International Nuclear Information System (INIS)

To ensure safe and reliable power production nuclear power plants must be operated at high level. Non destructive in-service inspections are inseparable part of the effort. Non destructive in-service inspections are essential on the ground of degradation mechanisms existence in nuclear power components. Degradation processes are constituent of operation of each industrial installation including nuclear power plants. Mission of non-destructive testing is degradation detection, closer characterization of its parameters (dimensions) and to supply as much information as possible to nuclear power plant operator. Eddy current testing method can be assigned to surface - volumetric methods. Method enables inspection of electrically conductive materials. It is particularly suitable for inspection of non-ferromagnetic materials like austenitic stainless steel and brass. The method is used for detection of stress corrosion cracking, pitting corrosion or ...

2006-01-01

87

Simulation and Observation of Acoustic-Gravity Waves in the Ionosphere  

Science.gov (United States)

Atmospheric and ionospheric perturbations associated with the acoustic-gravity waves (AGW) with typical frequencies of a few hertz -millihertz are considered. These events may be caused by the influence from space and atmosphere as well as by oscillations of the Earth surface and other near-surface phenomena. The surface sources include long-period oscillations of the Earth's surface, earthquakes, explosions, thermal heating, seisches and tsunami waves. The wavelike phenomena manifest themself as travelling disturbances of air (in the atmosphere) and of electron density (in the ionosphere). Travelling ionospheric disturbances (TIDs) are well detected by radio physical methods. AGW generation by near-surface sources is modeled by the numerical solution of the equation of geophysical fluid dynamics for different sources in two-dimensional non-linear dissipative compressible atmosphere. The numerical calculations are based on the FCT (Flux Corrected Transport) ...

2010-01-01

88

Somatic radiation risk in different mammography techniques  

International Nuclear Information System (INIS)

By measuring organ doses with TLD at an Alderson-Rando-phantom it was tested to evaluate the somatic risk for mammographies. Similarly as the genetic risk can be expressed by the genetic significant dose, the somatic risk can be expressed by the somatic significant dose index. The measurement results of the mammography show a large deviation of almost one power of ten with dependence of the chosen technique. In conventional xeroradiography and recording technique with foilless film the somatic radiation risk is the highest. By using amplifying foils in combination with high-sensitive films it is relatively small. Unfortunately the magnitude of the somatic risk in the different mammography techniques is in the ratio reciprocal to the corresponding image quality. At the time being the most favourable technique is mammography with a soft rastering method, although the xeromammography ...

1981-01-01

89

Optimal dynamic detection of explosives  

Energy Technology Data Exchange (ETDEWEB)

The detection of explosives is a notoriously difficult problem, especially at stand-off distances, due to their (generally) low vapor pressure, environmental and matrix interferences, and packaging. We are exploring optimal dynamic detection to exploit the best capabilities of recent advances in laser technology and recent discoveries in optimal shaping of laser pulses for control of molecular processes to significantly enhance the standoff detection of explosives. The core of the ODD-Ex technique is the introduction of optimally shaped laser pulses to simultaneously enhance sensitivity of explosives signatures while reducing the influence of noise and the signals from background interferents in the field (increase selectivity). These goals are being addressed by operating in an optimal nonlinear fashion, typically with a single shaped laser pulse inherently containing within it coherently locked ...

2009-01-01

90

Onset of nucleate boiling and onset of fully developed subcooled boiling using pressure transducers signals spectral analysis  

International Nuclear Information System (INIS)

The experimental technique used for detection of subcooled boiling through analysis of the fluctuation contained in pressure transducer signals is presented. This work was partly conducted at the Institut fuer Kerntechnik und zertoerungsfreie Pruefverfahren von Hannover (IKPH, Germany) in a thermal-hydraulic circuit with one electrically heated rod with annular geometry test section. Piezo resistive pressure sensors are used for onset of nucleate boiling (ONB) and onset of fully developed boiling (OFDB) detection using spectral analysis/ signal correlation techniques. Experimental results are interpreted by phenomenological analysis of these two points and compared with existing correlation. The results allow to conclude that this technique is adequate for the detection and monitoring of the ONB and OFDB. (author)

91

Onset of nucleate boiling and onset of fully developed subcooled boiling using pressure transducers signals spectral analysis  

Energy Technology Data Exchange (ETDEWEB)

The experimental technique used for detection of subcooled boiling through analysis of the fluctuation contained in pressure transducer signals is presented. This work was partly conducted at the Institut fuer Kerntechnik und zertoerungsfreie Pruefverfahren von Hannover (IKPH, Germany) in a thermal-hydraulic circuit with one electrically heated rod with annular geometry test section. Piezo resistive pressure sensors are used for onset of nucleate boiling (ONB) and onset of fully developed boiling (OFDB) detection using spectral analysis/ signal correlation techniques. Experimental results are interpreted by phenomenological analysis of these two points and compared with existing correlation. The results allow to conclude that this technique is adequate for the detection and monitoring of the ONB and OFDB. (author)

2001-12-01

92

Final report: technical contributions to the development of incipient fault detection/location instrumentation  

Energy Technology Data Exchange (ETDEWEB)

The transmission of electrical energy by use of underground cables is increasing. Fault location techniques have certain limitations; incipient fault detection and location would help reduce the maintenance cost of these lines as well as improve the reliability of service. The report discusses some test results related to RF-probing techniques applied to high-voltage transmission lines. The high-frequency losses and attenuation in high-voltage cables places certain ultimate limitations on RF-probing techniques for incipient fault detection. Time-domain reflectrometry methods were employed to assess the RF-transmission properties of high-voltage cables at frequencies as high as 6 GHz. Fast-Fourier-transform deconvolution was used to obtain loss measurements as a function of frequency. The loss mechanisms were identified. The measurement hardware and methods are discussed as well as ...

1986-04-01

93

Direct detection of Salmonella without pre-enrichment in milk, ice-cream and fruit juice by PCR against hilA gene  

British Library Electronic Table of Contents (United Kingdom)

A novel PCR based assay was devised to specifically detect contamination of any Salmonella serovar in milk, fruit juice and ice-cream without pre-enrichment. This method utilizes primers against hilA gene which is conserved in all Salmonella serovars and absent from the close relatives of Salmonella. An optimized protocol, in terms time and money, is provided for the reduction of PCR contaminants from milk, ice-cream and juice through the use of routine laboratory chemicals. The simplicity, efficiency (time taken 3-4 h) and sensitivity (to about 5-10 CFU/ml) of this technique confers a unique advantage over other previously used time consuming detection techniques. This technique does not involve pre-enrichment of the samples or extensive sample processing, which was a pre-requisite in mos...

2012-01-01

94

The Nuclear Smuggling International Technical Working Group: Making a difference in combating illicit trafficking  

International Nuclear Information System (INIS)

Full text: The ITWG was first formed in 1995 for the purpose of fostering international cooperation for combating illicit trafficking of nuclear materials. The initial focus for the ITWG was on the development of nuclear forensics to help answer attribution questions regarding nuclear materials of unknown origin. More recently, the ITWG has also expanded its focus to include detection of nuclear materials during transit. This paper presents some of the key developments by this group and their potential impact for combating nuclear smuggling. The initial focus of the ITWG was to write a status report on international cooperation on nuclear smuggling forensic analysis. This 26-page report summarized previous work on nuclear forensics and gave an initial analysis on prioritizing techniques and methods for forensic analysis regarding source and route attribution. This report was submitted to the G-8 countries, and shortly thereafter, nuclear ...

2002-10-21

95

Radiation therapy in the treatment of hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

The incidence of hilar cholangiocarcinoma is very rare worldwide. Radical resection is the only prognostic factor for long survival in patients with hilar cholangiocarcinoma. Postoperative radiation therapy can improve local control and survival rates for patients with palliative resection, but it remains controversial in patients with radical resection. Biliary drainage can effectively release bile duct obstruction for the majority of patients with locally advanced disease, and may even prolong survival when combined with radiation therapy. Radiation therapy includes extrernal beam therapy alone, external beam therapy with intraluminal brachytheapy and new radiation technique, such as three dimentional conformal therapy and intensity modulated radiation therapy. The propective randomized clinical study is needed for further investigation in the role of combined ...

2007-10-01

96

Basic mechanisms of radiation effects in the natural space radiation environment  

Energy Technology Data Exchange (ETDEWEB)

Four general topics are covered in respect to the natural space radiation environment: (1) particles trapped by the earth`s magnetic field, (2) cosmic rays, (3) radiation environment inside a spacecraft, (4) laboratory radiation sources. The interaction of radiation with materials is described by ionization effects and displacement effects. Total-dose effects on MOS devices is discussed with respect to: measurement techniques, electron-hole yield, hole transport, oxide traps, interface traps, border traps, device properties, case studies and special concerns for commercial devices. Other device types considered for total-dose effects are SOI devices and nitrided oxide devices. Lastly, single event phenomena are discussed with respect to charge collection mechanisms and hard errors. (GHH)

1994-06-01

97

Characterization of nuclear fuels by ICP mass-spectrometric techniques  

British Library Electronic Table of Contents (United Kingdom)

Isotopic analyses of radioactive materials such as irradiated nuclear fuel are of major importance for the optimization of the nuclear fuel cycle and for safeguard aspects. Among the mass-spectrometric techniques available, inductively coupled plasma mass spectrometry (ICP-MS) and thermal ionization mass spectrometry are the most frequently applied methods for nuclear applications. Because of the low detection limits, the ability to analyze the isotopic composition of the elements and the applicability of the techniques for measuring stable as well as radioactive nuclides with similar sensitivity, both mass-spectrometric techniques are an excellent amendment to classical radioactivity counting methods. The paper describes selected applications of multicollector ICP-MS in combination with c...

2008-01-01

98

Scattered radiation effect on the defect image in high-energy bremsstrahlung introscopy  

International Nuclear Information System (INIS)

Results of the evaluation of the scattered radiation effect on the image of defects in examined products are given. The formula is suggested which characterizes the image of defects on a scintillation screen as well as accumulation factors are calculated by the Monte-Carlo method. Values of fluctuations of absorbed energy in the screen used for the evaluation of sensitivity are experimentally obtained. The effect of high-energy bremsstrahlung on the defect detection is analyzed.

99

Heavy metals in welding fumes  

Energy Technology Data Exchange (ETDEWEB)

Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A /sup 241/Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer.

1984-10-01

100

Heavy metals in welding fumes  

International Nuclear Information System (INIS)

Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A "2"4"1Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer. (E.S.).

1984-01-01

101

Radiation protection  

International Nuclear Information System (INIS)

The book presents a very good account of all aspects of protection from ionizing radiation. The quantities and units are given and defined used in nuclear physics and dosimetry. The effects of ionizing radiation on cells and on man are described. The principles are presented of radiation protection including limits and valid regulations and decrees. Also discussed is internal irradiation and its modelling. A great part of the book is devoted to aspects of monitoring persons, the living and working environment and to the determination of internal contamination. The system of radiation protection in Czechoslovakia is described and some practical questions are discussed of protection during radiodiagnosis and radiotherapy, in the nuclear fuel cycle, in the operation of nuclear power installations and in crack detection. In conclusion a survey is given of the population exposure from ...

1988-01-01

102

Speckle Reduction for LIDAR Using Optical Phase Conjugation  

Energy Technology Data Exchange (ETDEWEB)

Remote detection of chemicals using LIDAR (Light Detection and Ranging) utilizing DIAL (Differential Absorption LIDAR) is now a standard detection technique for both military and civilian activities. We have developed a novel nonlinear optical phase conjugation system that can reduce the effects of speckle noise and atmospheric turbulence on DIAL remote detection systems. We have shown numerically and experimentally that it is possible to increase the signal-to-noise (S/N) ratio for LIDAR systems under certain conditions using optical phase conjugation. This increase in S/N can result in more accurate detection of chemical effluents while simultaneously reducing the time necessary to acquire this information.

2001-02-26

103

Radiotherapy for nonfunctioning pituitary adenomas: from conventional to modern stereotactic radiation techniques  

British Library Electronic Table of Contents (United Kingdom)

The initial management of nonfunctioning pituitary macroadenomas (NFAs) is usually surgery; however, a significant proportion of NFAs may require further treatment. Radiotherapy is currently used in patients with residual tumour and achieves excellent long-term control, but there are concerns about potential late toxicity. Stereotactic radiotherapy, both in the form of radiosurgery or fractionated stereotactic radiotherapy, has been developed as a more accurate technique of irradiation with more precise tumour localization and consequently a reduction in the volume of normal tissue, particularly the brain, irradiated to high radiation doses. A review of the literature suggests that new radiation techniques offer safe and effective treatment for recurrent or residual pituitary adenomas; how...

2007-01-01

104

Nondestructive testing of metal coating thickness and control of chemical composition using radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The principle is described of a method using low-activity emitters as the primary radiation source for analysis. The selection of the radiation source and the detection methods including the assessment of the applicability of various radiation detectors are discussed. The benefits and the constraints of the method are considered. Practical examples are presented showing the application possibilities of the method for testing the thickness of bearing layers, piston ring coats, lead layers, etc. The possibility is shown of applying the rapid test for the composition of tungsten and chromium alloyed metal materials in testing complex systems. (J.K.).

1974-12-03

105

Position sensitive detection of individual nuclear particle scintillations using image intensifier tubes  

International Nuclear Information System (INIS)

An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).

1996-01-01

106

The sensitivity of real-time PCR amplification targeting invasive Salmonella serovars in biological specimens  

UK PubMed Central (United Kingdom)

BackgroundPCR amplification for the detection of pathogens in biological material is generally considered a rapid and informative diagnostic technique. Invasive Salmonella...Full Text Available

107

Rapid technique of DNA-DNA in situ hybridisation on formalin fixed tissue sections using microwave irradiation.  

UK PubMed Central (United Kingdom)

The relative sensitivities of different protocols for detecting cytomegalovirus nucleic acid sequences in histological specimens, using a biotinylated cDNA probe, were assessed. Several commonly used...Full Text Available

1987-08-01

108

Rapid isolation and identification of group B streptococci from selective broth medium by slide co-agglutination test.  

UK PubMed Central (United Kingdom)

Direct identification of group B streptococci from a selective broth medium was performed with the Phadebact streptococcus test to determine the feasibility of this technique for early detection of...Full Text Available

1978-10-01

109

Novel remote sensing gas outburst detector  

Energy Technology Data Exchange (ETDEWEB)

The possibility has been explored of using a laser scattering technique to detect the imminent onset of rock activity associated with gas outbursts. The instrument described in this paper provides a sensitive, remote and rapid means of passively monitoring micro-seismic activity at the exposed face.

1984-08-01

110

High-Throughput Screen for Poly-3-Hydroxybutyrate in Escherichia coli and Synechocystis sp. Strain PCC6803  

UK PubMed Central (United Kingdom)

A novel, quantitative method for detecting poly-3-hydroxybutyrate (PHB) amounts in viable cells was developed to allow for high-throughput screening of mutant libraries. The staining technique was demonstrated...Full Text Available

2006-05-01

111

High-Sensitivity Analysis of Naturally Occurring Sugar Chains, Using a Novel Fluorescent Linker Molecule  

UK PubMed Central (United Kingdom)

To analyse the binding of sugar chains to proteins, viruses and cells, the surface plasmon resonance (SPR) technique is very convenient and effective because it is a real-time, non-destructive detection...Full Text Available

2009-07-01

112

Gene expression analysis of interferon ? in laser capture microdissected cervical epithelium  

UK PubMed Central (United Kingdom)

Optimal sample handling techniques for tissue preparation and storage, RNA extraction and quantification, and target gene detection are crucial for reliable gene expression analysis. Methods...Full Text Available

2008-10-01

113

Effect of Edge-Preserving Adaptive Image Filter on Low-Contrast Detectability in CT Systems: Application of ROC Analysis  

UK PubMed Central (United Kingdom)

Objective. For the multislice CT (MSCT) systems with a larger number of detector rows, it is essential to employ dose-reduction techniques. As...Full Text Available

2008-01-01

114

Development of Two PCR-Based Techniques for Detecting Helical and Coccoid Forms of Helicobacter pylori  

UK PubMed Central (United Kingdom)

The primary mode of transmission of Helicobacter pylori, a human pathogen carried by more than half the population worldwide, is still unresolved. Some epidemiological data suggest...Full Text Available

2004-08-01

115

Comprehensive SNP-chip for retinitis pigmentosa-Leber congenital amaurosis diagnosis: new mutations and detection of mutational founder effects  

UK PubMed Central (United Kingdom)

Fast and efficient high-throughput techniques are essential for the molecular diagnosis of highly heterogeneous hereditary diseases, such as retinitis pigmentosa (RP). We had previously approached RP...Full Text Available

2010-01-01

116

Results of UT training for defect detection and sizing technique using specimens with fatigue crack and SCC  

International Nuclear Information System (INIS)

At the importance increase of UT (ultrasonic testing) with the application of rules on fitness-for-service for nuclear power plants, JAPEIC (Japan power engineering and inspection corporation) started education training for defect detection and sizing technique. Weld joints specimen with EDM (Electro-Discharged Machining) notches, fatigue cracks and intergranular stress corrosion cracks were tested and practiced repeatedly based on a modified ultrasonic method and the defect size measuring accuracy of the trainees was surely improved. Results of the blind test confirmed effectiveness of education training. (T. Tanaka)

2005-04-01

117

On problems in trustworthy predictions of etched track parameters  

Energy Technology Data Exchange (ETDEWEB)

It is discussed here how trustworthy predictions of etched track parameters in nuclear track detection technique can be made? Problems involved in doing so are described along with discussion about their possible solutions. Arguments are presented using 5.2 MeV alpha particle track etching experiments with CR-39 detector and corresponding calculations using computer programs TRACK{sub V}ISION and TRACK{sub T}EST. Experimental and computational results in the present paper are useful for further basic research and technology applications of solid state nuclear track detection technique.

2008-10-15

118

Roentgenologic appearance of a thorotrast-induced small cholangiocarcinoma in a case of thorotrastosis  

International Nuclear Information System (INIS)

A small cholangiocarcinoma was detected at autopsy in a patient with thorotrastosis who died from the rupture of esophageal varices at the esophagogastric junction. Prior to the advent of recent diagnostic imaging technique, a correct antemortem diagnosis could only be obtained from tumor markers. However, the tendency for the opacity of the liver to decrease slowly with time and develop uneven trabeculation suggests that small tumors may be difficult to detect against such a non-homogeneous background. (author).

119

Detection of aortoarterial graft infections by leukocyte scintigraphy  

Energy Technology Data Exchange (ETDEWEB)

Infections of aortoarterial prostheses are serious, difficult to detect, and difficult to treat. Scintigraphy with indium-111 labeled autologous leukocytes is an accurate noninvasive method of assessing the presence and extent of such an infection. In three cases of aorto-arterial bypass graft infections, the leukocyte study was successful in establishing the diagnosis and in assessing the extent of infection. Other noninvasive diagnostic techniques are useful, but all have serious limitations. The leukocyte study alone appears to be free of likely sources of error.

1983-09-01

120

New mass screening project for lung cancer with mobile spiral computed tomography (CT) and computed radiography (CR) in Ehime district  

Energy Technology Data Exchange (ETDEWEB)

To improve the detection rate of lung cancer, we have introduced low-dose CT and CR technique into a population-based annual mass screening. From December 1999, 3868 and 12618 individuals participated in this screening program with CT and with CR, respectively. Primary lung cancer was detected in 15 (0.39%) by CT and 8 (0.06%) by CR. This results show high detection rate of primary lung cancer as had been previously reported. (author)

2002-01-01

121

Sandia microelectronics development  

Energy Technology Data Exchange (ETDEWEB)

An overview of the operations of Sandia`s Microelectronics Development Lab (MDL) is to develop radiation hardened IC, but techniques used for IC processing have been applied to a variety of related technologies such as micromechanics, smart sensors, and packaging.

1997-02-01

122

Intensity modulated radiotherapy: advantages, limitations and future developments  

UK PubMed Central (United Kingdom)

Intensity modulated radiotherapy (IMRT) is widely used in clinical applications in developed countries, for the treatment of malignant and non-malignant diseases. This technique uses multiple radiation...Full Text Available

123

X-ray imaging dose due to the digital imaging devices used in radiation therapy for patient positioning and repositioning: How to take it into account?; Les doses dues a l'imagerie numerique pour le controle de positionnement du patient en radiotherapie: comment les prendre en compte?  

Energy Technology Data Exchange (ETDEWEB)

The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)

2008-12-15

124

Development of calibration facility for radiation protection monitoring instruments  

International Nuclear Information System (INIS)

Exposure control at the operating Nuclear Power Station is a major concern. The challenging task of meeting the International standards in the field of radiation protection is the calibration of the radiation monitoring instruments and interpretation of personnel and area monitoring results. Correct interpretation is based on accurate calibration of radiation measuring instruments. The reliability and accuracy of the measurements are also partly based on the procedures applied in calibration. Inadequate calibration can cause large errors in dose estimation in complete dose rate range and energy range. Semiautomatic calibration facility established at TAPS 3 and 4 for radiation monitoring instruments. Objective of calibration facility is (a) Ensure instruments are working properly (b) calibration adjustment and (c) in case without calibration adjustment to reveal the error involved. The calibration ...

2008-11-19

125

Development of SDT sensor based eddy current probe for detection of deep fatigue cracks in multi-layer structure  

British Library Electronic Table of Contents (United Kingdom)

The detection and characterization of deeply buried fatigue damage in thick, multi-layer airframe components pose significant technical challenges to the aviation safety community. Currently, no nondestructive evaluation technique is available to reliably detect such potential damage from the exterior of the airframe, which is highly desirable in light of inspection cost as well as avoidance of structure damage. Recent technological advances in high-sensitivity magnetic sensors, i.e., spin-dependent tunneling (SDT) sensors, make it feasible to employ electromagnetic inspection techniques for deep fatigue crack inspection. In this work, we report on the development and fabrication of a low frequency eddy current probe based on a magnetically shielded SDT pickup sensor concentrically located...

2010-01-01

126

Analysis of Ground Deformation Detected Using the SBAS-DInSAR Technique in Umbria, Central Italy  

British Library Electronic Table of Contents (United Kingdom)

Ground deformation affecting the Umbria region (central Italy) in the 9-year period from 1992 to 2000 was investigated through multi-temporal Differential Synthetic Aperture Radar Interferometry (DInSAR). For the purpose, the Small BAseline Subset (SBAS) technique was adopted, which allows studying the temporal evolution of the detected deformation at two spatial scales: a low-resolution (regional) scale, and a full-resolution (local) scale. For the analysis, SAR data acquired by the European Remote Sensing (ERS-1/2) satellites along ascending and descending orbits were used. The detected deformation was analysed to investigate its relevance to geophysical, geomorphologic, and human-induced processes that may result in hazardous conditions to the population of Umbria. Low-resolution deform...

2009-01-01

127

A shallow subsurface controlled release facility in Bozeman, Montana, USA, for testing near surface CO2 detection techniques and transport models  

Energy Technology Data Exchange (ETDEWEB)

A controlled field pilot has been developed in Bozeman, Montana, USA, to study near surface CO2 transport and detection technologies. A slotted horizontal well divided into six zones was installed in the shallow subsurface. The scale and CO2 release rates were chosen to be relevant to developing monitoring strategies for geological carbon storage. The field site was characterized before injection, and CO2 transport and concentrations in saturated soil and the vadose zone were modeled. Controlled releases of CO2 from the horizontal well were performed in the summers of 2007 and 2008, and collaborators from six national labs, three universities, and the U.S. Geological Survey investigated movement of CO2 through the soil, water, plants, and air with a wide range of near surface detection techniques. An overview of these results will be presented.

2009-10-20

128

New concept in transmission line reclosure using high-frequency fault transients  

Energy Technology Data Exchange (ETDEWEB)

The authors present a new concept: 'adaptive optimal reclosure' under transmission line faults by integrating the adaptive and optimal reclosure techniques. Simulation studies prove that the proposed technique is able to first detect the persistence time of fault path arc and then capture the optimal reclosure time, thereby enhancing system stability. (author)

1997-07-01

129

Radiation decontamination of dry food ingredients and processing aids  

International Nuclear Information System (INIS)

Radiation decontamination of dry ingredients, herbs and enzyme preparations is a technically feasible, economically viable and safe physical process. The procedure is direct, simple, requires no additives and is highly efficient. Its dose requirement is moderate. Radiation doses of 3-10 kGy (0.3-1 mrad) have proved sufficient to reduce the viable counts to a satisfactory level. Ionising radiations do not cause any significant rise in temperature. The flavour, texture or other important technological or sensory properties of most ingredients are not influenced at radiation doses necessary for satisfactory decontamination, and radiation obviates the chemical residue problem. The microflora surviving radiation decontamination of dry ingredients are more susceptible to subsequent antimicrobial treatments. Recontamination can be prevented as the product can be ...

130

Spontaneous radiation from relativistic electrons in a taper undulator. Technical report  

Science.gov (United States)

The spectrum, angular distribution, polarization and coherence properties of the radiation emitted by relativistic electrons undulating through a quasiperiodic tapered magnetic field are studied. Tapering the wavelength and/or field strength along the undulator's axis has the effect of spreading the spectral line to higher frequencies; interference over this broader spectral range results in a more complex line shape. The angular dependence, on the other hand, is not affected by the amount of taper. The polarization of the radiation in the forward direction is determined by the transverse polarization of the undulator, but the polarization changes off axis. The radiation patterns predicted here are distinct from those of untapered undulators, and their detection is now feasible. They will provide useful diagnostics of electron trajectories and threshold behavior in free-electron-laser ...

1983-06-01

131

Formulation and practice of standards for radiation protection of #gamma#-ray industrial computed tomography  

International Nuclear Information System (INIS)

There are many differences between industrial CT and industrial radiography, such as imaging principle, inspection time, radiation dose and the requirements for operators etc. The national standards for radiation protection of industrial detection are not applicable to the requirements of protection and safety for #gamma#-ray industrial CT to some extent now. In order to standardize the production and use for #gamma#-ray industrial CT, protect the safety of operators and the public, and to promote the popularization and application of #gamma#-ray industrial CT, it is significant to establish the national standards for radiation protection of #gamma#-ray industrial CT as soon as possible. The purpose of this paper is to introduce the contents of this standard, and specify some important terms. Then there is a brief discussion on the existing problems during establishing such standards. At last, the paper ...

2009-03-01

132

Structure analysis of ferrite in deformed pearlitic steel by means of X-ray diffraction method with synchrotron radiation  

Energy Technology Data Exchange (ETDEWEB)

Structure of ferrite in drawn pearlitic steel containing 0.9 mass% C was investigated with X-ray diffraction technique using synchrotron radiation. In the detailed analysis of diffraction peaks of ferrite during the drawing process, it was experimentally revealed that the transformation of ferrite from bcc to bct due to the supersaturation of carbon in ferrite of heavily drawn pearlitic steel.

2004-07-15

133

Structure analysis of ferrite in deformed pearlitic steel by means of X-ray diffraction method with synchrotron radiation  

International Nuclear Information System (INIS)

Structure of ferrite in drawn pearlitic steel containing 0.9 mass% C was investigated with X-ray diffraction technique using synchrotron radiation. In the detailed analysis of diffraction peaks of ferrite during the drawing process, it was experimentally revealed that the transformation of ferrite from bcc to bct due to the supersaturation of carbon in ferrite of heavily drawn pearlitic steel.

2004-07-01

134

Resonant-mass detectors of gravitational radiation  

International Nuclear Information System (INIS)

A network of second-generation low-temperature gravitational radiation detectors is nearing completion. These detectors, sensitive to mechanical strains of order 10"-"1"8, are possible because of a variety of technical innovations that have been made in cryogenics, low-noise superconducting instrumentation, and vibration isolation techniques. Another five orders of magnitude improvement in energy sensitivity of resonant-mass detectors is possible before the linear amplifier quantum limit is encountered. 33 references, 3 figures, 1 table.

1987-07-01

135

Proton beam therapy for cancer in deep-seated organs  

Energy Technology Data Exchange (ETDEWEB)

Radiation therapy has shown definite technical improvement due to application of proton beam irradiation. Clinical results of proton beam therapy also suggested enlargement of indication ranges in radial treatment and decrease of post radiation damages of the treatment of cancers in deep-seated organs. Inprovement of result in cancer therapy could be expected by this treatment technique in the future.

1988-10-01

136

PIXE analysis of trace elements in relation to chlorophyll concentration in Plantago ovata Forsk  

Energy Technology Data Exchange (ETDEWEB)

Plantago ovata Forsk - an economically important medicinal plant - was analyzed for trace elements and chlorophyll in a study of the effects of gamma radiation on physiological responses of the seedlings. Proton-induced X-ray emission (PIXE) technique was used to quantify trace elements in unirradiated and gamma-irradiated plants at the seedling stage. The experiments revealed radiation-induced changes in the trace element and chlorophyll concentrations.

2010-03-15

137

Methods and results of a representative analysis of the radiation exposure of the population by diagnostic radiology  

International Nuclear Information System (INIS)

From the frequency of diagnostic radiologic examinations and their radiation dose delivered to the population the risk of cancer induction and genetic damage is calculated on the basis of the risk factors given by the ICRP. Thus 0.38 % and 3 % of the total mortality for cancer and leukemia, resp., can be attributed to X-ray diagnostics. Chest examinations alone result in 0.07-0.7 damages per 100,000 persons depending on the imaging technique applied. (author).

1984-01-01

138

Imaging techniques for the injured ankle joint and tarsal bones  

International Nuclear Information System (INIS)

In the case of injuries of the ankle joint, an imaging technique is expected to reveal the state of the bones, ligaments, and articular cartilage. Irrespective of novel imaging techniques, a plain radiography will be made in order to obtain a first picture of the injury. Examples are given, showing that further orientation along the Lauge-Hansen classification scheme of this type of injury helps to completely ascertain the damage to the Articulatio talocruralis. Further examinations applying specific methods such as arthrography will detect possible, isolated syndesmosis ruptures; lesions of the ligaments can also be directly detected by CT or MRT. The articular cartilage and its lesions can be visualized by a combination of CT and arthrography, but are better shown by the completely non-invasive MRT. This latter method also gives insight into pathological processes with the bone. It allows to ...

139

The role of brachytherapy in radiation and isotopes centre of Khartoum (RICK)  

International Nuclear Information System (INIS)

As there are many efforts devoted in order to manage the cancer, here the researcher handle one of these efforts that play a major part in treating the cancer internationally, it is a brachytherapy system. Brachytherapy was carried out mostly with radium sources, but recently some artificial sources are incorporated in this mode of treatment such as Cs-137, Ir-192, Au-198, P-32, Sr-90 and I-125. The research cover history of brachytherapy and radioactive sources used in, techniques of implementation, radiation protection and methods of brachytherapy dose calculation, as well as brachytherapy in radiation and isotopes centre in Khartoum.

140

Radiation hardening of semiconductor parts  

International Nuclear Information System (INIS)

This chapter is an overview of total-ionizing-dose and single-event hardening techniques and should be used as a guide to a range of research publications. It should be stressed that there is no clear and simple route to a radiation-tolerant silicon integrated circuit. What works for one fabrication process may not work for another, and there are many complex interactions within individual processes and designs. The authors have attempted to highlight the most important factors and those process changes which should bring improved hardness. The main point is that radiation-hardening as a procedure must be approached in a methodical fashion and with a good understanding of the response mechanisms involved.

141

Projection techniques in diagnostic radiography discussed with regard to required dose  

International Nuclear Information System (INIS)

The paper presents information in the form of data, tables and diagrams compiled to a broad but very up-to-date survey of required radiation for the various most frequently performed X-ray examinations of patients. The required dose is discussed from the point of view of radiation protection, defining the inevitably administered dose to the skin, the frequency of examinations, and the diagnostic image quality as the main three factors to be observed, as these determine the radiation dose to the patient and to the personnel. The somatic risks of radiography examinations are a point of main interest. (DG).

1990-09-01

142

Combined Modality Treatment for Prostate Cancer With Dynamic Adaptive Radiation Therapy Using Four-Dimensional Image-Guided Intensity-Modulated Radiation Therapy and Brachytherapy  

British Library Electronic Table of Contents (United Kingdom)

Prostate cancer can be successfully treated using dynamic adaptive external beam radiation techniques along with interstitial brachytherapy to deliver curative therapies with low urinary, rectal and erectile function morbidity. Through the use of sophisticated, state-of-the art radiographic imaging for staging and treatment planning, a precise, individual design for treatment is accomplished. Symptom management and patient education are of paramount importance and are integrated throughout the treatment process.

2009-01-01

143

Choice of distance from radiation source to tested object for gamma-absorption density measurer in divergent pencil of ray  

International Nuclear Information System (INIS)

Formulae are derived for estimation of the effect of gamma beam divergence on the value of systematic and statistical components of the errors of density measurement in production of structural materials and products also in the process of exploitation of building structures and constructions. Engineering technique for choice of the distance between radiation source and object under test is developed for absorption radioisotope densimeter operating by the scheme of geometry of divergent beam with amplitude compensation of backscattered radiation effect. The assessment of radioisotope densimeter efficiency providing the error of density measurement prescribed at design stage

144

The biodistribution and effect on hepatic parenchyma with intraarterial injected I-131 lipiodol into hepatic artery  

Energy Technology Data Exchange (ETDEWEB)

Iodized oil has been used as a contrast agent in lymphangiography. One of the commercially available compounds is Lipidol Ultra-fluid(LUF) which contains 38% iodine by weight. Nakakuma et al(1979) reported that LUF was selectively retained in the hypervascular hepatocellular carcinoma when injected directly into the ligated hepatic artery. Since that time, it has been widely utilized in the detection as well as the therapeutic attempts of hepatocellular carcinoma, where it has been mixed with chemotherapeutic agents or labeled with radioactive I-131. Like all significant advances, the mechanism of lipid retention within the hepatocellular carcinoma is not clearly understood, and also there is a lack of information about the biodistribution and kinetics of I-131 Lipiodol. The apparent safety of this technique require confirmation. The present study was aimed to assess the biodistribution and kinetics of intraarterially injected I-131 Lipiodol ...

1989-08-15

145

Gases in insulating oil - analysis of dissolved gases using a portable chromatograph  

Energy Technology Data Exchange (ETDEWEB)

New technological advances make it possible to perform on site gas-in-oil analysis quickly and efficiently. Gas-in-oil analysis is crucial in assessing the status of oil-filled electrical equipment. The new technique is used for extracting and measuring gases dissolved in electrical insulating oil. On-site sampling requires the use of a specially designed 100 ml capacity syringe. Extraction of the dissolved gases is made with a precise ratio of oil to air. A comparison was made between the analysis of the on-site and the laboratory techniques. Results showed that the detection limits of the on-site technique were comparable to those obtained by laboratory methods.

1996-07-01

146

Comparative evaluation of Computed Tomography and Magnetic Resonance Imaging (1.5 T) in the detection of brain metastases  

International Nuclear Information System (INIS)

Forty-four patients with small cell carcinoma of the bronchus underwent CT and MR studies of the brain to detect cerebral metastases. All patients were studied with contrast-enhanced CT scans, short (T1-weighted) and long (T2-weighted), spin-echo (SE) and FLASH 90 grades sequences were also obtained. A quantitative comparison of the results was carried out to assess the sensitivity of the different techniques in the detection of brain metastases according to lesion diameter. Metastases were identified in 19/44 patients (43%). All techniques detected the lesions >2 cm; of the metastases <2 cm, 63/124 (51%) were detected only by GdDTPA SE-T1 and FLASH sequences and 11 more (9%) only by Gd-DTPA SE-T1 scans. All the lesions identified oh enhanced CT scans or on T2-weighted images were easily detected by Gd-DTPA scans. CT sensitivity was ...

1991-01-01

147

New remote sensing techniques for the detection and quantification of earth surface CO2 degassing  

British Library Electronic Table of Contents (United Kingdom)

Earth degassing specifically of carbon dioxide CO2 is of increasing interest with respect to the global carbon budget, related climate effects, earthquake and volcano eruption mechanisms, as well as plant physiological reactions in gas-rich environments. Investigations in all of these disciplines require the detection of surface CO2 degassing structures and quantification of their emissions. We introduce minimal thermal change detection based on infrared imaging as a new remote sensing tool for the detection of earth surface thermal anomalies suiting among others to discover earth degassing locations of any origin. The method allows for seamless areal search and monitoring of degassing structures in any terrain. As proof of concept infrared imaging measurements were performed at the Bossol...

2008-01-01

148

Asymmetric Totally-corrective Boosting for Real-time Object Detection  

CERN Document Server

Real-time object detection is one of the core problems in computer vision. The cascade boosting framework proposed by Viola and Jones has become the standard for this problem. In this framework, the learning goal for each node is asymmetric, which is required to achieve a high detection rate and a moderate false positive rate. We develop new boosting algorithms to address this asymmetric learning problem. We show that our methods explicitly optimize asymmetric loss objectives in a totally corrective fashion. The methods are totally corrective in the sense that the coefficients of all selected weak classifiers are updated at each iteration. In contract, conventional boosting like AdaBoost is stage-wise in that only the current weak classifier's coefficient is updated. At the heart of the totally corrective boosting is the column generation technique. Experiments on face detection show that our methods ...

2010-01-01

149

State-of-the-art techniques for internal quality measurements in steel sheets production processes; Hakkoban seizo ni okeru naibu hinshitsu no onrain keisoku oyobi kensa gijutsu  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the state-of-the-art ultrasonic and magnetic measuring techniques developed at Kawasaki Steel and used in the production process of steel sheets are described. Representative examples shown here are as follows: (1) Magnetic flux leakage testing system for the detection of nonmetallic inclusions, (2) Nondestructive orientation measurement for secondary re-crystallized grains in grain-oriented electrical steel by ultrasonic interferometry, (3) Immersion testing method for the detection of nonmetallic inclusions, (4) Surface wave probe for the detection of surface flaws in rolls used in rolling mills. Developments of these techniques and their applications to actual steel sheets production processes have contributed to advance in technologies for quality assurance and control. With the help of these techniques, steel sheet products with advanced and ...

1999-12-01

150

Recent advances in analytical determination of cisplatin and its hydrolysis products  

International Nuclear Information System (INIS)

Cisplatin (cis-diaminedichloroplatinum [II] is a coordination compound, used in the treatment of several solid tumors. Cisplatin and its hydrolysis products exhibit a great pharmacological effect but are very toxic and probably carcinogenic. The present review summarizes the most important advances in the last years in the techniques employed for the detection and quantification of cisplatin and its hydrolysis products and in the different matrixes studied. The new emerging techniques and their modifications recently developed, fundamentally the combined use of detection and separation techniques for the analysis of platinum species and their impact on the speed, sensitivity and specificity of the analytical determination, with regard to the techniques used in the last century are discussed. High-Performance Liquid Chromatography and Capillary Electrophoresis, ...

2009-01-01

151

Compton scatter tomography and its inversion using a few projections  

Energy Technology Data Exchange (ETDEWEB)

Compton scatter tomography utilizes the electronic collimation characteristics available through the Compton scattering angle-energy correlation to obtain tomographic images. In this work we present particular aspects of the technique, which are relevant to the inverse radiation transport problem of reducing marginal projection data to radial two-phase flow regime maps. The results indicate a viable technique for the tomographic imaging of tow-phase flow using practical source strengths and reasonably few detectors.

1988-01-01

152

Studies of crystalline CdZnTe radiation detectors and polycrystalline thin film CdTe for X-ray imaging applications  

CERN Document Server

The development of a replacement to the conventional film based X-ray imaging technique is required for many reasons. One possible route for this is the use of a large area film of a suitable semiconductor overlaid on an amorphous silicon readout array. A suitable semiconductor exists in cadmium telluride and its tertiary alloy cadmium zinc telluride. In this thesis the spectroscopic characteristics of commercially available CZT X- and gamma-radiation detectors are established. The electronic, optical, electro-optic, structural and compositional properties of these detectors are then investigated. The attained data is used to infer a greater understanding for the carrier transport in a CZT radiation detector following the interaction of a high energy photon. Following this a method used to fabricate large area films of CdTe on a commercial scale is described. This is cathodic electrodeposition from an aqueous electrolyte. ...

2001-01-01

153

Measurements and elimination of Cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry  

International Nuclear Information System (INIS)

In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component ...

2007-08-21

154

Leachability of neutron irradiated fly ash  

Science.gov (United States)

Leachability of neutron irradiated fly ash is investigated as a method for studying element leaching properties of this material with various leaching media. Quantitative aspects of radiation damage are shown to be minor. Therefore, the technique should be applicable for this purpose. It is further shown that this technique affords significant advantages over the conventional post-leaching analysis with respect to utilization of natural solutions for the investigation of fly ash leachability. However, for a few elements such as Pb, Bi, V, and Al, the various nuclear parameters involved invalidate applicability of the present technique.

1977-11-01

155

Leachability of neutron irradiated fly ash  

International Nuclear Information System (INIS)

Leachability of neutron irradiated fly ash is investigated as a method for studying element leaching properties of this material with various leaching media. Quantitative aspects of radiation damage are shown to be minor. Therefore, the technique should be applicable for this purpose. It is further shown that this technique affords significant advantages over the conventional post-leaching analysis with respect to utilization of natural solutions for the investigation of fly ash leachability. However, for a few elements such as Pb, Bi, V, and Al, the various nuclear parameters involved invalidate applicability of the present technique.

1977-01-01

156

Boron-Lined Neutron Detector Measurements  

Energy Technology Data Exchange (ETDEWEB)

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. Reported here are the results of ...

2009-11-02

157

Prompt fission neutron energy spectra induced by fast neutrons  

International Nuclear Information System (INIS)

Prompt fission neutron energy spectra for "2"3"5U and "2"3"9Pu have been measured for fission neutron energies greater than the energy of the incident neutrons inducing fission. The measurements were undertaken to investigate the shape dependence of the fission neutron spectra upon both the incident neutron energy and the mass of the nucleus undergoing fission. Measurements were made for both nuclides at incident neutron energies of 0.50, 1.50, 2.50 and 3.50 MeV. The data are presented either as relative yields or as ratios of measured spectra to that of "2"3"5U at 0.50 MeV. Incident neutrons were produced by the "7Li(p,n)"7Be reaction using a pulsed, bunched proton beam from the 5.5 MV Van de Graaff accelerator at the University of Massachusetts Lowell Radiation Laboratory. Fission neutrons were detected by a thin liquid scintillator with good time resolution capabilities. Neutron energies were determined by time-of-flight ...

158

Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden  

Energy Technology Data Exchange (ETDEWEB)

The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. The good agreement ...

2007-11-15

159

Early forecast of radiation-hazardous solar cosmic ray fluxes on the neutron monitors data  

Science.gov (United States)

The system of the early forecast of radiation hazardous fluxes of solar cosmic rays in space on the basis of the real time neutron monitors data obtained by the NMDB (Neutron Monitor Data Base) network is created. The forecast system is based on a short cut technique of definition of a spectrum of solar protons from the data of the limited number of neutron monitor stations and with a simplified procedure of accounts. It is shown that the results of computations of solar proton spectra with the short-cut technique little differ from spectra obtained with a complete technique at energies less than 5 GeV. Thus the good agreement between derived from the neutron monitor data intensities of solar protons in an energy range of hundreds MeV with the data of direct measurements of solar protons at GOES-11 spacecraft is observed. The maximum of increase on neutron monitors outstrips on several hours (2-10) an ...

2010-01-01

160

The High-Redshift Neutral Hydrogen Signature of an Anisotropic Matter Power Spectrum  

CERN Document Server

An anisotropic power spectrum will have a clear signature in the 21cm radiation from high- redshift hydrogen. We calculate the expected power spectrum of the intensity fluctuations in neutral hydrogen from before the epoch of reionization, and predict the accuracy to which future experiments could constrain a quadrupole anisotropy in the power spectrum. We find that the Square Kilometer Array will have marginal detection abilities for this signal at z~17 if the process of reionization has not yet started; reionization could enhance the detectability substantially. Pushing to higher redshifts and higher sensitivity will allow highly precise (percent level) measurements of anisotropy.

2011-01-01

161

Non-destructive testing of refractories, especially AZS materials, with ultrasound, microwaves and {gamma}-radiation  

Energy Technology Data Exchange (ETDEWEB)

In principle four different methods (ultrasound, microwaves, {gamma}-radiation and x-rays) are available for the non-destructive testing of refractories. Three of these methods, i.e. ultrasound, microwaves and {gamma}-radiation, are in use by different producers of AZS materials to carry out the quality control of their products. This paper will compare the three methods on the basis of the physical properties, present the existing devices, and show the advantages as well as the limits of the different methods. {gamma}-radiography, the oldest method in use, has one main disadvantage, which is the requirement of protection against radioactive radiation. Furthermore, while cracks and cavities can be detected with this method, structural changes can not be monitored. Therefore, the ultrasonic method was developed that allows to detect variations of porosity and grain size as well as ...

1995-08-01

162

A miniaturized spatial temperature gradient capillary electrophoresis system with radiative heating and automated sample introduction for DNA mutation detection  

British Library Electronic Table of Contents (United Kingdom)

Abstract A miniaturized spatial temperature gradient CE system with automated sample introduction for DNA mutation detection was established. Continuous electrokinetic sample injection was achieved by combining an automated slotted vial array sample introduction device to the spatial temperature gradient CE system. The temperature gradient was produced by a radiative heating system with a single graphite block heater, and the stability of the temperature gradient was investigated. The temperature variation of each measure point was 0.12 0.21% RSD (n=7) within 6 h. A 14 cm Teflon AF coated silica capillary was used both as the separation channel and as the liquid core waveguide tube of fluorescence signal. Under a temperature gradient from 54.8 to 59.5 C, a low range control mutation standa...

2010-01-01

163

Magnetic resonance imaging in the evaluation of pneumonia; Nachweis von pneumonischen Infiltraten mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) of the lung is challenging because of substantial drawbacks. However, lung pathologies that are associated with increased attenuation values in CT enhance visualization in MRI: proton density is increased and tissue-air interfaces, resulting in susceptibility artifacts, are reduced in pneumonia, pneumonitis, edema, and carcinoma. On the other hand, many lung diseases result in shortness of breath, so that patients cannot hold their breath for long periods. Therefore, fast imaging techniques are required which should also allow for high spatial resolution so that small lesions can be detected. Calcifications and air pockets within lesions are not readily recognized with MRI. Thin section CT is standard for the diagnosis of pneumonia. With parallel imaging techniques, MRI examination of the lungs can be performed with short periods of breath holding, which allow for sub-centimeter resolution ...

2006-04-15

164

X-ray fluorescence analysis as auxiliary method of restorers  

International Nuclear Information System (INIS)

The principle is described of X-ray fluorescence analysis and the manner of detecting the emitted characteristic radiation. The advantages are presented of radionuclide X-ray fluorescence analysis which consist primarily in the possibility of conducting a totally non-destructive analysis, and of accurate and relatively narrow localization of the analyzed area, the simultaneous qualitative and quantitative determinations of a large number of elements in the order of concentrations 10"1 to 10"-"4%, stability of excitation radiation flux, simple design and relatively low capital costs. The so-called matrix effect is pointed to. A number of examples is given of the use of the cited method, including its use in the analysis of art objects. (J.B.).

1987-09-07

165

U.S. Government Capabilities to Support Analysis of Gamma Ray Data Submitted by Field Elements  

Energy Technology Data Exchange (ETDEWEB)

As radiation detection in the interest of national security becomes increasingly commonplace, inevitable questions arise concerning the interpretation of data from handheld radioisotope identifiers (RIIDs). Field elements typically require fast answers to provide an effective defense and to minimize the impact on legitimate movement of people and goods. To support this need, on-call experts at Sandia, Los Alamos, and Lawrence Livermore national laboratories cooperate in resolving radiation alarms rapidly and accurately. We present an overview, describe the work in progress to improve capabilities, and report on some of the lessons learned.

2005-07-07

166

To the problem of the Cherenkov radiation of tachyons  

International Nuclear Information System (INIS)

It is shown that the Cherenkov radiation of tachyons (CRT) in general case cannot possess axial symmetry with respect to velocity v. This implies that tachyons must be vector particles. Electric dipole is used as a vector characterising the tachyon. Formulas describing the CRT spectrum are derived taking into account the asymmetry for charged tachyon and neutral tachyon dipole with arbitrary orientation with respect to v. It is shown that both types of CRT possess the same integral characteristics. A new integral of motion specific for tachyons is found. Negative results of all attempts to detect the CRT are explained.

167

The circadian rhythm for the number and sensitivity of radiation-induced apoptosis in the crypts of mouse small intestine  

Energy Technology Data Exchange (ETDEWEB)

Survival curves were constructed from dose-incidence curves for apoptosis in the crypts of mouse small intestine, using the number of apoptotic cells after high doses (N{sub M}) as maximum cell population size. The mean lethal doses (D{sub 0}) for the dose range 0-0.5 Gy were calculated for each time of day. A circadian rhythm in both D{sub 0} and N{sub M} values was detected, indicating that both the number and sensitivity of radiation-induced apoptosis were changing throughout the day. (author).

1990-07-01

168

Coherent Synchrotron Radiation as a Diagnostic Tool for the LCLS Longitudinal Feedback System  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL). To ensure the vitality of FEL lasing, a longitudinal feedback system is required together with other diagnostics. In this paper, we study the possibility of using Coherent Synchrotron Radiation (CSR) from the chicane as a diagnostic tool for bunch length feedback. Studies show that CSR is a good candidate, even for a non-Gaussian, double-horn longitudinal charge distribution as in the LCLS. We further check the possibility for detecting possible microbunching.

2005-06-15

169

Basic radiation sterilization properties of packaging materials  

International Nuclear Information System (INIS)

The foils of various materials were irradiated with "6"0Co with an activity of 11,538 TBq. The minimum radiation dose was 25 kGy. Changes in chemico-physical properties were evaluated by infrared spectroscopy and were not detected after irradiation with 25 kGy. Packing foils were subjected to the following tests: mechanical tests, tests of weld strength, tests of impact resistance, free fall tests, permeability tests for water vapour and microbiological tests. The results of all tests were tabulated. The tests showed that the foils are impermeable for microorganisms and provided the welds are airtight the packed products remain sterile. (J.P.).

1984-11-28

170

The use of molecular biology techniques for the diagnosis and epidemiological study of foot-and-mouth disease virus in Thailand  

International Nuclear Information System (INIS)

The detection of foot-and-mouth disease (FMD) virus from various kinds of field samples (tissue extract and cell culture isolate) was studied using the polymerase chain reaction (PCR) technique. The gene selected for diagnosis was the polymerase gene and an amplification target product of 454 bp in length was produced using AP5/AP6 primer sets. The PCR product was further examined by NcoI endonuclease digestion. The presence of the internal restriction site was confirmed by demonstration of two small fragments of 330 bp and 124 bp in length. Forty-nine samples that gave positive and negative results by ELISA typing and were positive by the PCR test were tested by NcoI digestion to confirm the results. About 10% of PCR products could not be confirmed by the method. Furthermore the FMD RNA polymerase gene could be detected by the PCR method in samples negative in both ELISA typing and the virus isolation test. A total of 23 ...

2000-05-01

171

Pulse source of electron and X-ray radiations of subnanosecond duration  

International Nuclear Information System (INIS)

The time and dose characteristics of the electron and X-ray radiations of a tube, connected to a subnanosecond mega volt accelerator, are measured. By the pulse of the accelerating voltage of #>=# 600 kV with duration of #approx =# 0.3 ns the tube generates approximately 5 x 10"1"2 electrons pulse. The current amplitude equals approximately 5 kA/pulse and the radiation dose-about 5 kGy/pulse. The X-ray radiation dose from the tantalum external target constitutes 0.15 Gy/pulse. The prototypes of the electron and X-ray tubes sufficiently lower volumes, opening new applications in the technique and medicine, are developed

172

Paediatric radiography - the avoidance of late radiation damage to the growing hip  

Energy Technology Data Exchange (ETDEWEB)

Epiphyseal plates of growing bones are sensitive to ionizing radiation and this poses problems for the paediatric radiotherapist. In this case report we describe a child in whom electron beam therapy to the groin delivered only low dose radiation to the proximal hip epiphyses - 130 cGy fractionated over 5 weeks - but who suffered late maldevelopment. We explore the success of various radiotherapy techniques in minimizing the dose to the hip epiphyses in four other children. The appropriate positioning of the limb, the choice of treatment modality and, where possible, individual shielding blocks are considered and their effect on the dose to the hip estimated. Absorbed doses of radiation delivered to the midpoint of the proximal femoral epiphyses have been retrospectively determined. (author).

1993-04-01

173

New Radiation Stable and Long-Lived Plastic Scintillators  

International Nuclear Information System (INIS)

A study of the influence of the concentration of secondary addition, high concentrations of primary dopant, diffusion enhancer and stabilizer on radiation hardness is presented. It is concluded that the diffusion enhancing technique is the most powerful method for improving radiation hardness. A new polystyrene scintillator which contains 2% pT, 0.02% POPOP, 20% diffusion enhancer and 0.02% stabilizer gave 91% of initial light output immediately after 3 Mrad irradiation in air. Data are presented that show that scintillator prepared from commercial polymer is more radiation-hard and has greater light output than scintillator prepared from monomer. It is assumed that this difference is due to different molecular weight distributions. Some protocols for acceleration of aging (yellowing and crazing) are presented. It is shown that one of the main reasons for aging of plastic scintillators is residual ...

1993-11-15

174

Coherent spontaneous radiation from highly bunched electron beams  

International Nuclear Information System (INIS)

Coherent spontaneous radiation has now been observed in several FELs, and is a subject of great importance to the design of self-amplified spontaneous emission (SASE) devices. We report observations of coherent spontaneous radiation in both FIREFLY and the mid-infrared FEL at the Stanford Picosecond FEL Center. Coherent emission has been observed at wavelengths as short as 5 microns, and enhancement over incoherent levels by as much as a factor of 4x10"4 has been observed at longer wavelengths. The latter behavior was observed at 45 microns in FIREFLY with short bunches produced by off-peak acceleration and dispersive compression. We present temporal measurements of the highly bunched electron distributions responsible for the large enhancements, using both transition radiation and energy-phase techniques.

1995-08-21

175

Programmable radionuclide X-ray fluorescence multi-channel spectrometric analyzer, type 123-1  

International Nuclear Information System (INIS)

The whole equipment consists of three separate portable parts: a detector case, a microprocessor and a graphic TV monitor. Magnetic tape memory and an x-y recorder can be connected for recording the measured spectra. The analyzer contains two built-in exchangeable excitation radionuclides. Fluorescence and scattered radiation is detected using a proportional detector. The detected pulses are analyzed by a 256-channel analyzer and the results are shown on the display. The device may be used in mining laboratories, coal and ore dressing plant control rooms or in mining fields of open cast mines for quick detection of the quality of mined or dressed raw materials. (E.S.). 1 fig.

1988-01-01

176

Gear fault detection using customized multiwavelet lifting schemes  

Science.gov (United States)

Fault symptoms of running gearboxes must be detected as early as possible to avoid serious accidents. Diverse advanced methods are developed for this challenging task. However, for multiwavelet transforms, the fixed basis functions independent of the input dynamic response signals will possibly reduce the accuracy of fault diagnosis. Meanwhile, for multiwavelet denoising technique, the universal threshold denoising tends to overkill important but weak features in gear fault diagnosis. To overcome the shortcoming, a novel method incorporating customized (i.e., signal-based) multiwavelet lifting schemes with sliding window denoising is proposed in this paper. On the basis of Hermite spline interpolation, various vector prediction and update operators with the desirable properties of biorthogonality, symmetry, short support and vanishing moments are constructed. The customized lifting-based multiwavelets for feature matching are chosen by the ...

2010-07-01

177

Detection of explosives  

Energy Technology Data Exchange (ETDEWEB)

An analyser for detecting explosives has at least one neutron source and a plurality of gamma ray detectors. An article to be analysed is moved adjacent the source and detectors and is subjected to neutrons which generate gamma rays from any nitrogen in the article. The gamma rays are detected and analysed to determine the nitrogen concentration within the article. In order to achieve an area of uniform detection there are a plurality of detectors equidistant both from the or each source and from the article to be analysed. In order to avoid a decrease in sensitivity away from the source(s) and detectors there may be a second opposing array of source(s) and detectors on the opposite side of the article. For greatest uniformity of detection, a source in one array opposes a detector in the other array and vice versa. Transmission of radiation from the analyser is kept at safe levels ...

1991-03-13

178

Coated semiconductor devices for neutron detection  

Energy Technology Data Exchange (ETDEWEB)

A device for detecting neutrons includes a semi-insulated bulk semiconductor substrate having opposed polished surfaces. A blocking Schottky contact comprised of a series of metals such as Ti, Pt, Au, Ge, Pd, and Ni is formed on a first polished surface of the semiconductor substrate, while a low resistivity ("ohmic") contact comprised of metals such as Au, Ge, and Ni is formed on a second, opposed polished surface of the substrate. In one embodiment, n-type low resistivity pinout contacts comprised of an Au/Ge based eutectic alloy or multi-layered Pd/Ge/Ti/Au are also formed on the opposed polished surfaces and in contact with the Schottky and ohmic contacts. Disposed on the Schottky contact is a neutron reactive film, or coating, for detecting neutrons. The coating is comprised of a hydrogen rich polymer, such as a polyolefin or paraffin; lithium or lithium fluoride; or a heavy metal fissionable material. By varying the coating thickness and ...

2002-01-01

179

Trans-generational radiation-induced chromosomal instability in the female enhances the action of chemical mutagens  

Energy Technology Data Exchange (ETDEWEB)

Genomic instability can be produced by ionising radiation, so-called radiation-induced genomic instability, and chemical mutagens. Radiation-induced genomic instability occurs in both germinal and somatic cells and also in the offspring of irradiated individuals, and it is characterised by genetic changes including chromosomal rearrangements. The majority of studies of trans-generational, radiation-induced genomic instability have been described in the male germ line, whereas the authors who have chosen the female as a model are scarce. The aim of this work is to find out the radiation-induced effects in the foetal offspring of X-ray-treated female rats and, at the same time, the possible impact of this radiation-induced genomic instability on the action of a chemical mutagen. In order to achieve both goals, the quantity and quality of chromosomal damage were ...

2008-04-02

180

Distributed radiation protection console system  

International Nuclear Information System (INIS)

Radiation exposure control is one of the most important aspects in any nuclear facility . It encompasses continuous monitoring of the various areas of the facility to detect any increase in the radiation level and/or the air activity level beyond preset limits and alarm the O and M personnel working in these areas. Detection and measurement of radiation level and the air activity level is carried out by a number of monitors installed in the areas. These monitors include Area Gamma Monitors, Continuous Air Monitors, Pu-In-Air Monitors, Criticality Monitors etc. Traditionally, these measurements are displayed and recorded on a Central Radiation Protection Console(CRPC), which is located in the central control room of the facility. This methodology suffers from the shortcoming that any worker required to enter a work area will have to inquire about the ...

2004-02-01

181

Plane electrode device for multiwire detector for ionizing radiations  

International Nuclear Information System (INIS)

A multiwire proportional counter type detector with thin slits instead of wires is presented. It can detect either charged particles (positive or negative) or radiation. The detector can be used as a counter or as an image converter. In radiography, it can replace photographic film or TV camera systems. It can also be used to measure particle or radiation energy. The slits which replace wires in the anode are introduced between two parallel microstrip conductors with different potentials. A quasi-polar electric field is produced between these strips. To obtain high fields, the slits are extremely narrow. Microstrips less than a micron can be obtained, giving structural dimensions of a few microns, i.e., 100 times smaller than the spacing in a classic wire anode.

1986-07-01

182

Detection of irradiated chicken by ESR spectroscopy of bone  

Energy Technology Data Exchange (ETDEWEB)

Ionizing radiation has been used to treat poultry to remove harmful microorganisms, mainly Salmonella, which contaminates chicken, goose and other fresh and frozen poultry. This microorganism is sensitive to low dose radiation. Thus, irradiating these foods with doses between 1 to 7 kGy results in a large reduction of bacteria. Since it is necessary to determine whether irradiation has occurred and to what extend, this work studied the signal produced by ionizing radiation within the hard crystalline matrix of chicken`s bone to establish a control method. Chicken`s drumsticks were irradiated and bones separated from flesh were lyophilized and milled. ESR spectrum was then obtained. The ESR signal increased linearly with dose over the range 0.25 to 8.0 kGy. Free radicals evaluated during 30 days after irradiation showed stable in this period. (Author).

1995-10-01

183

Precise Measurement of the Neutron Magnetic Form Factor G{sub M}{sup n} in the Few-GeV{sup 2} Region  

Science.gov (United States)

The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q{sup 2}=1.0-4.8 GeV{sup 2} with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.

2009-05-15

184

Precise Measurement of the Neutron Magnetic Form Factor GMn in the Few-GeV2 Region  

International Nuclear Information System (INIS)

The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q2=1.0-4.8 GeV2 with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.

2009-05-15

185

In-beam #gamma#-ray spectroscopy of fast beams at the NSCL  

International Nuclear Information System (INIS)

With the development of an array of highly-segmented germanium detectors, it now becomes possible to perform in-flight #gamma#-ray spectroscopy experiments on intermediate energy beams with unprecedented #gamma#-ray energy resolution. Presented in this report are examples of two techniques in which SeGA, the most highly-segmented operational germanium array for in-flight spectroscopy with fast beams, was used for the detection of #gamma# rays. SeGA used in conjunction with a high-resolution magnetic spectrograph (S800) to detect the reaction residues in coincidence represents a powerful combination for in-beam #gamma#-ray studies.

2004-04-05

186

Final report of the specific research. Investigations on the analysis of bio-protective factors against radiation. 1998-2000 FY (Research Group of NIRS)  

Energy Technology Data Exchange (ETDEWEB)

This report concerns investigations in the title conducted by 8 groups of National Institute of Radiological Sciences (NIRS) during the period of 1998-2000. The groups are for investigation of: Effects of p53 tumor suppressor gene in radiation-induced leukemia, Role of atm-gene in dose rate effect of ionizing radiation, Function of DNA-dependent protein kinase catalytic subunit (DNA-PK{sub cs}), Functional complementation of radiation-sensitive mutant M10 cell line by human XRCC4 cDNA expression, Role of radiation-induced apoptosis in digital defects in embryonic mice, Functional analysis of S-phase specific novel nuclear protein NP95 by gene targeting, Role of chemokine in T cell development and lymphomagenesis, and establishment of production techniques of gene-modified mice using embryonic stem cells for genetic analysis of radiation-sensitive genes. The ...

2002-03-01

187

Adaptive Management of Liver Cancer Radiotherapy  

British Library Electronic Table of Contents (United Kingdom)

Adaptive radiation therapy for liver cancer has the potential to reduce normal tissue complications and enable dose escalation, allowing the potential for tumor control in this challenging site. Using adaptive techniques to tailor treatment margins to reflect patient-specific breathing motions and image-guidance techniques can reduce the high dose delivered to surrounding normal tissues while ensuring that the prescription dose is delivered to the tumor. Several treatment planning and delivery techniques have been developed for use in the liver, including a margin to encompass the full breathing motion, mean position techniques, which evaluate the probability of tumor location during breathing, breath hold, gating, and tracking. Patient selection, clinical workflow, and quality assurance m...

2010-01-01

188

The Galactic Exoplanet Survey Telescope (GEST)  

CERN Document Server

The Galactic Exoplanet Survey Telescope (GEST) will observe a 2 square degree field in the Galactic bulge to search for extra-solar planets using a gravitational lensing technique. This gravitational lensing technique is the only method employing currently available technology that can detect Earth-mass planets at high signal-to-noise, and can measure the frequency of terrestrial planets as a function of Galactic position. GEST's sensitivity extends down to the mass of Mars, and it can detect hundreds of terrestrial planets with semi-major axes ranging from 0.7 AU to infinity. GEST will be the first truly comprehensive survey of the Galaxy for planets like those in our own Solar System.

2002-01-01

189

New procedures. Comprehensive staging of lung cancer by MRI  

International Nuclear Information System (INIS)

Lung cancer staging according to the TNM system is based on morphological assessment of the primary cancer, lymph nodes and metastases. All aspects of this important oncological classification are measurable with MRI. Pulmonary nodules can be detected at the clinically relevant size of 4-5 mm in diameter. The extent of mediastinal, hilar and supraclavicular lymph node affection can be assessed at the same time. The predominant metastatic spread to the adrenal glands and spine can be detected in coronal orientation during dedicated MRI of the lungs. Search focused whole body MRI completes the staging. Various additional MR imaging techniques provide further functional and clinically relevant information during a single examination. In the oncological context the most important techniques are imaging of perfusion and tumor motion. Functional MRI of the lungs complements the pure staging and improves ...

2010-08-01

190

Investigation of the aroma impact volatiles in Turkish pine honey samples produced in Marmaris, Data and Fethiye regions by SPME/GC/MS technique  

British Library Electronic Table of Contents (United Kingdom)

Summary The aroma impact volatiles of twenty-four pine honey samples produced in Marmaris, Data and Fethiye regions of Turkey were evaluated by solid phase micro extraction/gas chromatography/mass spectrometry (MS) technique and the results were evaluated by using the analysis of variance and Duncan tests. A total of eight common volatiles nonanal, nonanol, decanal, octanal, 16-oxosalutaridine, dodecanal, nonadecane and pentadecane were detected in three regions. The total area of the common volatiles were 73.01%, 78.10% and 73.91% in Marmaris, Data, and Fethiye regions, respectively. There were not significant differences (P-<-0.05) between the common volatiles detected in pine honey samples from three different regions. The major contributers to the pine honey aroma seems to be nonanal (...

2011-01-01

191

Biomagnetic separation of Salmonella Typhimurium with high affine and specific ligand peptides isolated by phage display technique  

Energy Technology Data Exchange (ETDEWEB)

Analyses of food-borne pathogens are of great importance in order to minimize the health risk for customers. Thus, very sensitive and rapid detection methods are required. Current conventional culture techniques are very time consuming. Modern immunoassays and biochemical analysis also require pre-enrichment steps resulting in a turnaround time of at least 24 h. Biomagnetic separation (BMS) is a promising more rapid method. In this study we describe the isolation of high affine and specific peptides from a phage-peptide library, which combined with BMS allows the detection of Salmonella spp. with a similar sensitivity as that of immunomagnetic separation using antibodies.

2007-04-15

192

Use of signal delay of one of detectors in two-channel radiometric flaw detector  

International Nuclear Information System (INIS)

A possibility is considered or reducing the surface heterogeneity effect of an item being tested on the result of radiation flaw detection by means of signal delay of one of detectors in a two-channel radiometric flaw detector. The exposure of a translationally moving item has been studied as well as an external exposure of a rotating hollow item.

193

Test of superconducting Nb/Al bilayers as particle detectors  

Energy Technology Data Exchange (ETDEWEB)

Superconducting thin film particle detectors can be very attractive due to the low sensitivity to radiation damage. We describe the fabrication procedure and the characterization of Nb/Al bilayers as particle detectors. First steady and dynamical results are reported from tests of 5 MeV alpha-particle detection.

2000-04-07

194

Search for tachyons associated with extensive air showers in the ground level cosmic radiation  

International Nuclear Information System (INIS)

Events detected in a shielded plastic scintillation counter occurring in the 26 microsec preceding the arrival of an extensive air shower at ground level with local electron density or = 20 m to the -2 power and the 240 microsec after its arrival have been studied. No significant excess of events (tachyons) arriving in the early time domain have been observed in a sample of 11,585 air shower triggers.

1985-08-01

195

Lysis of phespholipid membranes with radiation-induced free radicals  

International Nuclear Information System (INIS)

Phospholipid vesicles were found to be lysed by exposure to free radicals derived from irradiated glycine and galactose. The decomposition yield increased with vesicle concentration, and attained values of 0.0006 vesicles destroyed per radical added. Ionic charge at the phospholipid end groups was found to be more important than degree of unsaturation in determining this yield. Radicals derived from irradiated serine and alanine had no detectable lytic action at the vesicle concentrations tested.

1977-05-01

196

In vivo99mTc-HYNIC-annexin V imaging of early tumor apoptosis in mice after single dose irradiation  

UK PubMed Central (United Kingdom)

BackgroundApoptosis is a major mode of hematological tumor death after radiation. Early detection of apoptosis may be beneficial for cancer adaptive treatment. 99mTc-HYNIC-annexinV...Full Text Available

197

Gene rearrangement and radiation carcinogenesis  

International Nuclear Information System (INIS)

The development of leukemia and thyroid cancer is characterized by activation of the abl oncogene and ret oncogene, respectively. In order to clarify the relationship between these gene aberrations and radiation, the pro-myelogenous leukemia-derived cell line HL60 and the thyroid cancer-derived cell line 8505C, were irradiated in vitro with 100Gy of X-rays. RNA was then extracted from 10"8 cells of the respective cell lines and examined by the reverse transcription PCR method for rearrangements of abl and ret genes. Five kinds of positive bands were observed in the HL-60 cells irradiated with 100Gy of X-ray. Similarly, six positive bands were also observed in the 8505C cells irradiated with 100Gy. In vitro X-irradiation activation of oncogenes found in radiation induced cancers imply that gene rearrangement by X-rays is involved in the development of malignant tumors. Furthermore, in an experiment to detect ...

1993-11-01

198

Estimation of errors provided with dead times of roentgen digital tomography  

International Nuclear Information System (INIS)

Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computer tomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained

199

Enhancement of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 (16N) and Oxygen-19 (19O) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of 19O and 16N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high ambient radiation level even though sensitivity is appreciably good. For detector position in RB in the accessible ...

2006-11-13

200

An experimental plan for improvement of failed fuel monitoring system in CANDU reactor  

Energy Technology Data Exchange (ETDEWEB)

An experimental plan for improving the problems of failed fuel location system in Wolsung Unit-2 reactors was established. It is not possible to make an experiment on the failed fuel monitoring nuclides in the cold laboratories because they have very short half life. Therefore, the experiments can be only carried out at the existing monitoring system under reactor operation. For that reason, an experimental plan was drawn up for installing the radiation detection system on reactor site.

2003-10-01

201

Measuring characteristics on emissivity using infrared thermometer for RCCS  

International Nuclear Information System (INIS)

In VHTGR (Very High Temperature Gas-cooled Reactor), the radiation plays an important role in heat transfer through the cavity in RCCS (Reactor Cavity Cooling System). We performed the series of experiments to measure the emissivity using the infrared thermometer with wavelength range of 8#approx#14 #mu#m. As the first step, the transmittance of Zinc Selenide (ZnSe) window was measured to estimate the emissivity that can compensate the attenuation effect of window. The kind of gas with various concentrations in the cavity will be released during postulated accidents to the coolant type, so it is essential to estimate the effects of gas on the measurement of emissivity. In this manner we measured the emissivity with the air, the helium and the steam inside chamber. The results represent that the concentration of the air and the helium do not affect the emissivity significantly while the steam decreases the measured emissivity relatively. It means that the air and ...

2004-12-01

202

Sorbent extraction and high performance liquid chromatography (HPLC) of homidium bromide and isometamidium chloride in bovine plasma  

International Nuclear Information System (INIS)

Homidium bromide and isometamidium chloride are used extensively in the treatment of bovine trypanosomiasis in Africa, but no specific and sensitive method to detect the drug in plasma has been published yet. Comparing the methods of other investigators it was found that they could not overcome the protein binding of these drugs which reduced the available and determined drug to 10% of the real concentrations. These techniques overcome the protein binding by enzyme digestion and an alteration of the pH before adding the sample directly on clean-up columns. Drug recover rates above 80% were obtained. For the detection, the HPLC was employed using a C18 reversed phase analytical column and UV detection, determining both drugs as intact molecules. (author).

1992-01-01

203

Recursive neural networks for processing graphs with labelled edges: theory and applications.  

Science.gov (United States)

In this paper, we introduce a new recursive neural network model able to process directed acyclic graphs with labelled edges. The model uses a state transition function which considers the edge labels and is independent both from the number and the order of the children of each node. The computational capabilities of the new recursive architecture are assessed. Moreover, in order to test the proposed architecture on a practical challenging application, the problem of object detection in images is also addressed. In fact, the localization of target objects is a preliminary step in any recognition system. The proposed technique is general and can be applied in different detection systems, since it does not exploit any a priori knowledge on the particular problem. Some experiments on face detection, carried out on scenes acquired by an indoor camera, are reported, showing very promising results. ...

2005-09-21

204

Prospects for the direct detection of the cosmic neutrino background  

Energy Technology Data Exchange (ETDEWEB)

The existence of a cosmic neutrino background - the analogue of the cosmic microwave background - is a fundamental prediction of standard big bang cosmology. Up to now, the observational evidence for its existence is rather indirect and rests entirely on cosmological observations of, e.g., the light elemental abundances, the anisotropies in the cosmic microwave background, and the large scale distribution of matter. Here, we review more direct, weak interaction based detection techniques for the cosmic neutrino background in the present epoch and in our local neighbourhood. We show that, with current technology, all proposals are still off by some orders of magnitude in sensitivity to lead to a guaranteed detection of the relic neutrinos. The most promising laboratory search, based on neutrino capture on beta decaying nuclei, may be done in future experiments designed to measure the neutrino mass through decay kinematics. ...

2009-01-15

205

Mining User Comment Activity for Detecting Forum Spammers in YouTube  

CERN Document Server

Research shows that comment spamming (comments which are unsolicited, unrelated, abusive, hateful, commercial advertisements etc) in online discussion forums has become a common phenomenon in Web 2.0 applications and there is a strong need to counter or combat comment spamming. We present a method to automatically detect comment spammer in YouTube (largest and a popular video sharing website) forums. The proposed technique is based on mining comment activity log of a user and extracting patterns (such as time interval between subsequent comments, presence of exactly same comment across multiple unrelated videos) indicating spam behavior. We perform empirical analysis on data crawled from YouTube and demonstrate that the proposed method is effective for the task of comment spammer detection.

2011-01-01

206

Diagnostic and Prognostic Utility of t(14;18) in Follicular Lymphoma  

British Library Electronic Table of Contents (United Kingdom)

Abstract Background: Follicular lymphoma (FL) is one of the most common non-Hodgkin's lymphomas of B cells, being closely associated with a t(14;18) translocation. Detection of t(14;18), which is present in 70-95% of FL, might aid in FL diagnosis. Objective: To compare the efficacy of routine polymerase chain reaction (PCR) and fluorescence in situ hybridization (FISH) techniques in detecting t(14;18) in paraffin-embedded tissue samples of FL patients at different stages. Combined with other immunophenotypic biological determinants, detection of t(14;18) might help to determine patients at increased risk according to the FL International Prognostic Index (FLIPI) and therefore facilitate appropriate treatment. Design and Methods: This study was mainly based on a retrospective examination of...

2007-01-01

207

Detecting hot spots at hazardous-waste sites  

Energy Technology Data Exchange (ETDEWEB)

Evaluating the need for remedial cleanup at a waste site involves both finding the average contaminant concentration and identifying highly contaminated areas, or hot spots. A nomographic procedure to determine the sample configuration needed to locate a hot spot is presented. The technique can be used to develop a waste-site sampling plant - to determine either the grid spacing required to detect a hot spot at a given level of confidence, or the probability of finding a hot spot of a certain size, given a particular grid spacing. The method and computer program (ELIPGRID) were developed for locating geologic deposits, but the basic procedure can also be used to detect hot spots at chemical- or nuclear-waste disposal sites. Nomographs based on the original program are presented for three sampling-grid configurations - square, rectangular and triangular.

1984-07-09

208

An effective method to estimate multidimensional Gaussian states  

CERN Document Server

A simple and efficient method for characterization of multidimensional Gaussian states is suggested and experimentally demonstrated. Our scheme shows analogies with tomography of finite dimensional quantum states, with the covariance matrix playing the role of the density matrix and homodyne detection providing Stern-Gerlach-like projections. The major difference stems from a different character of relevant noises: while the statistics of Stern-Gerlach-like measurements is governed by binomial statistics, the detection of quadrature variances correspond to chi-square statistics. For Gaussian and near Gaussian states the suggested method provides, compared to standard tomography techniques, more stable and reliable reconstructions. In addition, by putting together reconstruction methods for Gaussian and arbitrary states, we obtain a tool to detect the non-Gaussian character of optical signals.

2009-01-01

209

A Comprehensive Survey of Data Mining-based Fraud Detection Research  

CERN Document Server

This survey paper categorises, compares, and summarises from almost all published technical and review articles in automated fraud detection within the last 10 years. It defines the professional fraudster, formalises the main types and subtypes of known fraud, and presents the nature of data evidence collected within affected industries. Within the business context of mining the data to achieve higher cost savings, this research presents methods and techniques together with their problems. Compared to all related reviews on fraud detection, this survey covers much more technical articles and is the only one, to the best of our knowledge, which proposes alternative data and solutions from related domains.

2010-01-01

210

Edge filter and fringe imaging for laser Doppler wind speed measurement  

Science.gov (United States)

Optical measurement of the Doppler shift of laser backscatter, using a near-IR, visible, or ultraviolet laser, is potentially more robust and field reliable than coherent, heterodyne measurement with an IR laser. The direct measurement of the displacement of Fabry-Perot interference fringes is possible, but entails expensive, technically challenging, imaging detectors. The 'edge technique' permits Doppler shift measurements with relatively simple detectors and detector electronics, and has been implemented with Fabry-Perot etalons and with atomic line filters. Simple analytical models of the fringe imaging and edge detection techniques are presented, permitting ready calculation of the potential performance of either, for various atmospheric conditions and for various lidar hardware configurations. The predictions of the analytical models are confirmed by computer models, which in turn allow more detailed considerations of ...

1997-08-01

211

Position of nuclear-medical techniques for evaluation of loosened total hip endroprostheses  

Energy Technology Data Exchange (ETDEWEB)

For diagnosis of loosening or infection after implantation of a single-side or double-side total hip endoprosthesis 59 patients being in pain were investigated by a combination of bone scan (Technetium-99m DPD) and leucocyte scan (Indium-111 labelled leucocytes). The correlation between clinical results and scintigraphic findings revealed: bone scintigraphy detects loosening of prostheses with 95% sensitivity (45/47); bone scintigraphy excludes an instable prosthesis with 89% specificity (3/27). 45% of the loosened prostheses revealed an infection (21/47): leucocyte scintigraphy could detect 17 correct positive. Three leucocyte scans of 53 prostheses without clinical signs of infection were false positive. Therefore, leucocyte scintigraphy had a sensitivity of 91% and a specificity of 94% for detecting infection. Bone scintigraphy can detect loosening of prostheses with 93% accuracy, Indium-111 labelled ...

1985-10-01

212

Gravitational waves interferometer and the VIRGO project  

CERN Document Server

Radio, optical and X-rays telescopes are improving our knowledge of deep space. All these telescopes detect electromagnetic radiation at various frequencies. But a different kind of radiation is generated in the deeper space; it is the gravitational one. Gravitational waves change the space-time metric. As a consequence, GW telescopes should detect an extremely small strain (h < 10/sup -21/) of the geometry of a reference frame; if the frame has a reference dimension (L) of some kilometers, the deformation amplitude ( Delta L = h * L) is limited to 10/sup -16/ meters. Laser interferometers are the most suitable devices to make precise measurements of distances. Their resolution is limited by the laser wavelength ( lambda = 10/sup -6/ meters) and by the light wave-shift detection capability ( Delta Phi = 1 ppb). These theoretical limits are strongly degraded by different noise ...

2002-01-01

213

Subsurface imaging using the spectral polarization difference technique and NIR illumination  

Energy Technology Data Exchange (ETDEWEB)

A subsurface imaging system is utilized to test the ability of the spectral polarization difference imaging technique for deep subsurface imaging in tissues. The illumination of the system is derived from compact class III lasers in the red and NIR spectral region and, alternatively, from a white light source and selection of the appropriate illumination wavelength using band-pass optical filters. The experimental results demonstrate detection and imaging of a high-scattering object located up to 1.5 cm underneath the surface of a host chicken tissue.

1999-01-26

214

New techniques for electron-ion collision studies  

International Nuclear Information System (INIS)

We have constructed an apparatus to study electron impact ionization of ions which should provide additional insight into the mechanisms involved. Using multiparameter coincidence techniques, we will detect both outgoing electrons from ionization process and will be able to analyze the momenta of both particles simultaneously. Coupled with a high resolution electron gun, this information should have broad application to the difficult problem of three bodies interacting via the long range Coulomb force. If sufficient accuracy can be achieved, information regarding the relative phase of the outgoing electron wavefunctions can be obtained.

215

Ion beam analysis of high temperature superconducting samples  

Energy Technology Data Exchange (ETDEWEB)

Characterization of high temperature superconducting film and bulk samples has been carried out using 2 MeV [alpha]-particle Rutherford backscattering, 2.4 MeV proton elastic scattering, 2.4 MeV proton-induced x-ray emission, 9 MeV proton induced [gamma]-ray emission and 100 MeV iodine elastic recoil detection analysis techniques. The objective was to compare different ion beam based techniques for: (i) compositional analysis; and (ii) consistency of the results obtained for samples prepared using similar preparation methodology. (author).

1994-02-01

216

Determination of uranium and thorium concentrations in integrated circuit packaging materials  

International Nuclear Information System (INIS)

The purpose of the present research is to find a suitable technique to measure trace amounts of uranium and thorium and to determine the surface #alpha#-flux in silicon compound (SiO) used for fabrication of integrated circuit packaging materials. Among several commonly-used detecting techniques, it was found that neutron activation analysis (NAA) was most promising. The results from NAA show a large difference in uranium and thorium concentrations when cadmium and boron carbide shields are used, whereas #alpha#-flux measurements show a low #alpha#-activity, which corresponds to the trace amounts of uranium and thorium expected to be present in these materials. (author) 13 refs.; 6 figs.

217

Radioanalytical methods of rare earth element determination  

International Nuclear Information System (INIS)

Instrumental neutron activation analysis (INAA) and radionuclide X-ray fluorescence analysis (RXFA) were used for the determination of rare earth elements. For INAA, solution obtained by sample decomposition was dripped onto filter paper, enclosed and sealed into a polyethylene foil. The sample was activated in reactor WWR-S over a period of 4 to 6 hours with a neutron fluence of 10"1"3cm"-"2. Gamma radiation measurement was carried out with a planar and a coaxial HP-Ge detector in three decay periods. La, Ce, Nd, Sm, Eu, Gd, Tb, Ho, Tm, Yb and Lu were determined. The advantage of the method is its accuracy and high sensitivity, the disadvantage is the time-consuming analysis. The RXFA method was used as a rapid and operative method for the analysis of loose ore samples, aqueous and organic solutions of rare earth elements. For exciting X-ray radiation, "2"4"1Am was used and the radiation of K-lines was ...

1989-06-01

218

Magnetospheric Emissions from the Planet Orbiting tau Boo: A Multi-Epoch Search  

CERN Document Server

All of the solar system gas giants produce electron cyclotron masers, driven by the solar wind impinging on their magnetospheres. Extrapolating to the planet orbiting tau Boo, various authors have predicted that it may be within the detection limits of the 4-meter wavelength (74 MHz) system on the Very Large Array. This paper reports three epochs of observations of tau Boo. In no epoch do we detect the planet; various means of determining the upper limit to the emission yield single-epoch limits ranging from 135 to 300 mJy. We develop a likelihood method for multi-epoch observations and use it to constrain various radiation properties of the planet. Assuming that the planet does radiate at our observation wavelength, its typical luminosity must be less than about 10^{16} W, unless its radiation is highly beamed into a solid angle Omega << 1 sr. While within the range of ...

2007-01-01

219

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two detectors, respectively ...

2007-01-01

220

Aging and compatbility of TNF-doped mylar  

Energy Technology Data Exchange (ETDEWEB)

TNF-doped Mylar is a new radiation-hard dielectric that has recently been qualified as a viable substitute for Mylar in capacitors. The advantage of TNF-doped Mylar is that it satisfies both the nuclear safety and radiation hardness requirements of weapons. Mylar is not radiation-hard. Aging and compatibility studies were carried out to insure that (1) TNF does not diffuse from the film during fabrication of the capacitor or during storage; and (2) there are no compatibility problems with aluminum foil (the conductor) or Fluorinert (the secondary dielectric). Losses of TNF were barely detectable during the vacuum bakes used in fabricating capacitors or during accelerated aging tests carried out below T{sub g} (70C) over a two year period in air. In other accelerated tests, no compatibility problems were detected with aluminum or Fluorinert. TNF-doped Mylar is now being used in the ...

1990-01-01

221

Distortion-invariant color pattern recognition using multiple phase-shifted-reference-based joint transform correlation incorporating synthetic discriminant function  

Science.gov (United States)

This paper proposes a new pattern recognition system employing optical joint transform correlation (JTC) technique which offers a great number of advantages over similar digital techniques, including very fast operation, simple architecture and capability of updating the reference image in real time. The proposed JTC technique incorporates a synthetic discriminant function (SDF) of the target image estimated from different training images to make the pattern recognition performance invariant to noise and distortion. It then involves four different phase-shifted versions of the same target SDF reference image, which are individually joint transform correlated with the given input scene. When the correlation signals are combined, it produces a single cross-correlation peak corresponding to each potential target present in the given input scene. The proposed technique also includes a fringe-adjusted filter ...

2011-04-01

222

Detection of high-frequency radiation sources during the 2004 Parkfield earthquake by a matched filter analysis  

Science.gov (United States)

Introduction Uchide and Ide [SSA Spring Meeting, 2009] proposed a new framework for studying the scaling and overall nature of earthquake rupture growth in terms of cumulative moment functions. For better understanding of rupture growth processes, spatiotemporally local processes are also important. The nature of high-frequency (HF) radiation has been investigated for some time, but its role in the earthquake rupture process is still unclear. A wavelet analysis reveals that the HF radiation (e.g., 4 - 32 Hz) of the 2004 Parkfield earthquake is peaky, which implies that the sources of the HF radiation are isolated in space and time. We experiment with applying a matched filter analysis using small template events occurring near the target event rupture area to test whether it can reveal the HF radiation sources for a regular large earthquake. Method We design a matched filter for multiple components and ...

2009-12-01

223

Resistance of radiation-induced tropical wood-polymer composites to fungal degradation  

Energy Technology Data Exchange (ETDEWEB)

The resistance of six tropical hardwoods to fungal degradation by two wild-type strains of Phanerochaete chrysosporium Burdsall was investigated using vermiculite burial and wood-block weight loss techniques. Radiation-induced wood-polymer composites (WPC), based on two hardwoods Ramin and Rubberwood with methyl methacrylate, were prepared, and samples were also exposed to the wood-rotting fungus. A significant improvement in resistance to fungal decay was observed in the WPC. Scanning-electron micrographs of the two woods and their composites after fungal degradation are presented and discussed.

1987-01-01

224

Quantum tunnelling for Hawking radiation from a dynamical Black Hole  

CERN Document Server

The paper deals with Hawking radiation related to non-static spherically symmetric black hole. Quantum corrections are incorporated using Hamilton-Jacobi method beyond semi-classical approximation. It is found that different order correction terms satisfy identical differential equation as the semiclassical action and are solved by a typical technique. It has been shown that with proper choice of the proportionality factors, one loop back reaction effect in the space time can be obtained. Finally, using the law of black hole mechanics, a general modified form of the black hole entropy is obtained considering modified Hawking temperature.

2011-01-01

225

IRSL characteristics of NaCl and KCl relative to dosimeter  

Energy Technology Data Exchange (ETDEWEB)

The aim of this work is to determine and compare the dosimetric properties of NaCl and KCl samples using infrared-stimulated luminescence (IRSL) technique. For a material to be used as dosimeter, both the IRSL temperature dependence and the radiation dose response have critical importance. In this work the IRSL characteristics from NaCl and KCl samples were experimentally investigated as a function of temperature and laboratory radiation doses. Dosimetric properties of NaCl and KCl samples were found significantly different. The IRSL signals displayed by NaCl were found to be more stable, reliable and agreeable than those of KCl.

2007-01-15

226

Effects of thermophoresis and radiation on laminar flow along a semi-infinite vertical plate  

British Library Electronic Table of Contents (United Kingdom)

The present contribution deals with the thermophoresis particle deposition and thermal radiation effects on the flow, heat and mass transfer characteristics in a viscous fluid over a semi-infinite vertical porous plate. The governing boundary layer equations are written into a dimensionless form by similarity transformations. The transformed coupled nonlinear ordinary differential equations are solved numerically by means of the fourth-order Runge?Kutta method with a shooting technique. The effects of different parameters on the dimensionless velocity, temperature, and concentration profiles are shown graphically. In addition, results for the local skin-friction coefficient, the local Nusselt number, and the local Sherwood number are tabulated and discussed.

2011-01-01

227

Effects of thermophoresis and radiation on laminar flow along a semi-infinite vertical plate  

Science.gov (United States)

The present contribution deals with the thermophoresis particle deposition and thermal radiation effects on the flow, heat and mass transfer characteristics in a viscous fluid over a semi-infinite vertical porous plate. The governing boundary layer equations are written into a dimensionless form by similarity transformations. The transformed coupled nonlinear ordinary differential equations are solved numerically by means of the fourth-order Runge-Kutta method with a shooting technique. The effects of different parameters on the dimensionless velocity, temperature, and concentration profiles are shown graphically. In addition, results for the local skin-friction coefficient, the local Nusselt number, and the local Sherwood number are tabulated and discussed.

2011-04-01

228

CT colonography: techniques of visualization and findings; CT Kolonographie: Techniken der Visualisierung und Befundung  

Energy Technology Data Exchange (ETDEWEB)

Evaluation and interpretation of CT colonography is based on both 2D and 3D techniques. The 2D techniques are popular mainly because the time needed for evaluation is short. The 3D techniques allow better definition than the 2D techniques, especially of polyps close to folds or at the base of a fold. The evaluation strategies generally accepted so far (primarily 2D, with 3D for problem cases, or vice versa) demand knowledge of both 2D and 3D techniques. Newer 3D visualization techniques help make it possible to acquire more complete and faster recording particularly of areas that are not easily accessible to endoscopic examination. These user-friendly developments are thus well suited to improving the detection and the security of detection of polyps. It must be remembered that experience and the knowledge of associated ...

2008-02-15

229

Traces of evidence. Nuclear forensics and illicit trafficking  

International Nuclear Information System (INIS)

An IAEA databank lists a number of reported cases of illicitly trafficked nuclear or other radioactive materials. Apart from the traditional concern with nuclear proliferation, the post September 11th public is now wary of a possible attack by terrorists with a nuclear or radiation dispersion device (RDD). Until now, the seized quantities have not been sufficient to manufacture a nuclear explosive device, but they might be enough to construct an RDD. Recognizing the latent global challenge to public health and safety, the G8 States (Japan, USA, Germany, France, UK, Italy, Canada, and Russia) have called for 'joint international efforts to identify and suppress illicit supply' of, and demand for, nuclear material and to deter potential traffickers. One measure gaining in significance is to identify seized material and trace it back to its origin the objective of an emerging science known as nuclear forensics. Repeatedly nuclear or other radioactive material of ...

2003-06-01

230

Comparative evolution of various CCD image sensors hardening techniques with ionizing radiation  

International Nuclear Information System (INIS)

This paper reviews various techniques to harden Charged Coupled Device (CCD) sensors and the results after irradiation of three Thomson n buried channel CCDs having a different degree of hardening. It describes the major irradiation effects on CCD performances and it makes a comparison of the results between the different hardening levels. It shows good results on dark voltage after ionizing radiation for TH 7863M device hardened both by design and by operating conditions (MPP mode) with respect to the standard device TH 7863A. The irradiations were performed with "6"0Co or X-ray (10 keV) sources on devices in operating mode. (author). 3 refs., 8 figs.

231

Study of the effect of gamma radiation on the molecule of tetracycline concerning its behavior as complexing and extracting agent; Estudo do efeito da radiacao gama sobre a molecula de tetraciclina relativamente ao seu comportamento como agente complexante e extrator  

Energy Technology Data Exchange (ETDEWEB)

Both solvent extraction and spectrophotometric techniques were used to show the alterations that gamma radiation causes in the behavior of tetracycline molecule as far as its extracting and complexing power are concerned. The effect of gamma radiation on the solid tetracycline molecule, benzyl alcohol and on the solution of both was examined in solvent extraction systems whose aqueous phases were made up by {sup 152} Eu-{sup 154}Eu radioactive tracer solutions and whose organic phases were constituted by tetracycline-benzyl alcohol solutions. Experiments were performed in order to determine whether or not the water used for the pre-saturation of benzyl alcohol would influence the radiolysis of tetracycline. Solvent extraction and spectrophotometry were the techniques used to obtain the necessary data. Absorption spectra of irradiated tetracycline benzyl alcohol solutions submitted to several gamma ...

1982-07-01

232

Survival of gas phase amino acids and nucleobases in space radiation conditions  

CERN Document Server

We present experimental studies on the photoionization and photodissociation processes (photodestruction) of gaseous amino acids and nucleobases in interstellar and interplanetary radiation conditions analogs. The measurements have been undertaken at the Brazilian Synchrotron Light Laboratory (LNLS), employing vacuum ultraviolet (VUV) and soft X-ray photons. The experimental set up basically consists of a time-of-flight mass spectrometer kept under high vacuum conditions. Mass spectra were obtained using photoelectron photoion coincidence technique. We have shown that the amino acids are effectively more destroyed (up to 70-80%) by the stellar radiation than the nucleobases, mainly in the VUV. Since polycyclic aromatic hydrocarbons have the same survival capability and seem to be ubiquitous in the ISM, it is not unreasonable to predict that nucleobases could survive in the interstellar medium and/or in comets, even as a ...

2008-01-01

233

Normalized noise power spectrum of full field digital mammography detector system  

International Nuclear Information System (INIS)

Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)

234

Normalized Noise Power Spectrum of Full Field Digital Mammography System  

International Nuclear Information System (INIS)

A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.

2010-01-05

235

Non-destructive Imaging of Individual Bio-Molecules  

CERN Document Server

Radiation damage is considered to be the major problem that still prevents imaging an individual biological molecule for structural analysis. So far, all known mapping techniques using sufficient short wave-length radiation, be it X-rays or high energy electrons, circumvent this problem by averaging over many molecules. Averaging, however, leaves conformational details uncovered. Even the anticipated use of ultra-short but extremely bright X-ray bursts of a Free Electron Laser shall afford averaging over 10^6 molecules to arrive at atomic resolution. Here we present direct experimental evidence for non-destructive imaging of individual DNA molecules. In fact, we show that DNA withstands coherent low energy electron radiation with deBroglie wavelength in the Angstrom regime despite a vast dose of 10^8 electrons/nm^2 accumulated over more than one hour.

2009-01-01

236

Native Synthetic Imaging of Smoothed Particle Hydrodynamics density fields using gridless Monte Carlo Radiative Transfer  

CERN Document Server

An algorithm for creating synthetic telescope images of Smoothed Particle Hydrodynamics (SPH) density fields is presented, which utilises the adaptive nature of the SPH formalism in full. The imaging process uses Monte Carlo Radiative Transfer (MCRT) methods to model the scattering and absorption of photon packets in the density field, which then exit the system and are captured on a pixelated image plane, creating a 2D image (or a 3D datacube, if the photons are also binned by their wavelength). The algorithm is implemented on the density field directly: no gridding of the field is required, allowing the density field to be described to an identical level of accuracy as the simulations that generated it. Some applications of the method to star and planet formation simulations are presented to illustrate the advantages of this new technique, and suggestions as to how this framework could support a Radiative Equilibrium ...

2010-01-01

237

Minimizing radiation dose to patient and staff during fluoroscopic, nasoenteral tube insertions  

Energy Technology Data Exchange (ETDEWEB)

Since the fluoroscopic image during nasoenteral tube placements is used for guidance and not for diagnosis, a lower contrast image with increased quantum mottle can be easily tolerated. The three methods to reduce the radiation dose rate investigated consisted of removing camera from the image intensifier output phosphor, and setting the fluoroscopic mA to the minimum value so that the kVp could be maximized. Fluoroscopic frozen video frames of a clinical tube insertion comparing the images with and without the dose-saving techniques are presented. Measurements of the radiation dose rates using a Plexiglas phantom show that the dose for patient and staff during fluoroscopic-guided nasoenteral tube placements can be reduced by over a factor of 10 without significantly adversely affecting the actual placement procedure. (author).

1992-02-01

238

Measurement of the ratio of liquid to solid phases in a continuous ingot  

International Nuclear Information System (INIS)

A radiometric method of measuring the ratio of liquid and solid phases (crust thickness) in a continuous ingot for automation of the continuous steel casting process, has been proposed. The essence of the method is, that radiation flux, bearing information on the object tested, is transformed in a succession of electric pulses, which is processed afterwords for obtaining necessary information. In this case either the flux of non-scattered radiation, passed through the object, or the flux of single-scattered radiation reflected from the object is registered. Block-diagram and specifications of a radiometric device with the Co source of 50 gxequiv. Ra activity developed for this purpose are presented. The technique for calibration ob the device and the results of its tests, are described. It is shown, that introduction of such devices for the control crust thickness at the installations of continuous ...

239

Eddy current array probe for detection of surface breaking cracks in the extrados of feeder bends  

Energy Technology Data Exchange (ETDEWEB)

A new eddy current array probe has been implemented as a straightforward and promising technique for detection of outer diameter (OD) surface-breaking cracks on the extrados of feeder bends. The design is based on previous work performed at AECL, which had demonstrated that eddy current probes with laterally displaced transmit-receive coils can overcome some of the limitations of inspecting ferritic steel components for surface-breaking cracks. The Feeder Integrity Joint Program-CANDU Owners Group Inc. (FIJP-COG) Non-Destructive Evaluation (NDE) Team members commissioned AECL to work in collaboration with the probe manufacturer ZETEC, to develop a field usable eddy current array probe. The objective was to acquire a technique with the following capabilities: fast scanning non-contact inspection technique for surface breaking discontinuities; full inspection of the bend extrados OD surface in a single ...

2006-07-01

240

Eddy current array probe for detection of surface breaking cracks in the extrados of feeder bends  

International Nuclear Information System (INIS)

A new eddy current array probe has been implemented as a straightforward and promising technique for detection of outer diameter (OD) surface-breaking cracks on the extrados of feeder bends. The design is based on previous work performed at AECL, which had demonstrated that eddy current probes with laterally displaced transmit-receive coils can overcome some of the limitations of inspecting ferritic steel components for surface-breaking cracks. The Feeder Integrity Joint Program-CANDU Owners Group Inc. (FIJP-COG) Non-Destructive Evaluation (NDE) Team members commissioned AECL to work in collaboration with the probe manufacturer ZETEC, to develop a field usable eddy current array probe. The objective was to acquire a technique with the following capabilities: fast scanning non-contact inspection technique for surface breaking discontinuities; full inspection of the bend extrados OD surface in a single ...

2005-11-20

241

Preliminary studies on the detection of irradiated prawns using 2-alkylcyclobutanones  

Energy Technology Data Exchange (ETDEWEB)

The use of ionising radiation for the preservation of food has been under investigation for many years but has yet to receive worldwide acceptance. Although irradiation can be carefully controlled, it is generally accepted that the development of a test or tests for the detection of irradiated food would enhance consumer confidence and might help to enforce labelling regulations. The 2-alkylcyclobutanones are reported to be the only cyclic compounds formed as the products of the radiolysis of saturated and unsaturated triglycerides. The synthesis of 2-dodecylcyclobutanone (DCB) and 2-tetradecylcyclobutanone (TCB), which are formed from palmitic and stearic acid respectively following irradiation, has been carried out and using irradiated chicken meat as the model for a high-lipid containing food, both cyclobutanones have been extracted with hexane and then identified using gas chromatography/mass spectrometry (GC/MS). DCB and TCB have been ...

1996-12-31

242

Thermal NDE method for thermal spray coatings  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a feasibility demonstration of a thermal scanning NDE system for thermal spray coatings. Non-bonds were detected between several types of coatings and their substrates. Aluminum anti-skid coatings having very rough surfaces were included. A technique for producing known non-bond areas for calibrating and demonstrating NDE methods was developed.

1982-01-01

243

Technical and economic assessment of computer vision for industrial inspection and robotic assembly  

Energy Technology Data Exchange (ETDEWEB)

The use of computer vision to detect, measure, and perhaps guide the assembly of man-made components is potentially a very significant research and development area. The efficacy of these techniques for any given application depends on both technical and economic considerations. This paper will explore both these considerations using appropriate generic examples. It is our goal to first present a concise discussion of the present state of many technical and economic factors and then extrapolate these factors into the future for the purpose of guiding further investigations.

1981-12-01

244

Spectrophotometric technique quantitatively determines NaMBT inhibitor in ethylene glycol-water solutions  

Science.gov (United States)

Spectrophotometric method, using a ratio-recording ultraviolet-absorption spectrophotometer, permits analysis of NaMBT in ethylene glycol-water solutions with high accuracy. It reduces analysis time, requires smaller samples, and is able to detect extremely small concentrations of mercaptobenzothiazole.

1967-01-01

245

Potential U.S. contributions to in-reactor experiments for fast reactor surveillance systems  

International Nuclear Information System (INIS)

It is maintained that special features of FFTF make it an ideal system to test sodium boiling detection techniques by acoustic/neutronic methods and to test the response of acoustic/neutronic sensors to vibrations. It is shown that accumulated research results indicate that such tests in FFTF are feasible, predictable, promising and safe. (author).

246

Neutron detection techniques for plasma diagnostics at the Joint European Torus (JET)  

International Nuclear Information System (INIS)

The importance of neutron measurements both as a succinct measure of the progress to fusion ignition using the magnetic confinement route and also as a diagnostic of plasma conditions is discussed. The various neutron diagnostic systems that have been or are being constructed by AERE Harwell for JET are described. The properties to be measured by such diagnostics are clearly identified and some results obtained with the installed diagnostics during d-d plasmas are presented.

247

Monitoring for Xenon Radionuclides and CTBT Verification  

International Nuclear Information System (INIS)

The Comprehensive Nuclear-Test-Ban-Treaty (CTBT), which was opened for signature in 1996, bans all nuclear explosions in all environments. Republic of Korea has been working to monitor compliance with CTBT by deterring and detecting any nuclear explosions conducted anywhere on Earth. For the verification of CTBT, several techniques are implemented. Radionuclide monitoring is of particular importance since it is the only method which can provide absolute assurance that a nuclear detonation has occurred

2010-10-01

248

Mammography: limits of a technique  

International Nuclear Information System (INIS)

Breast cancer represents today more than 30% of all cancers and is responsible for about 20% of deaths due to cancer. The potentialities of mammography have increased in recent years through improvements in equipment and methodologies. In this paper the conventional mammography using film and image intensifiers is compared with digital mammography. Digital mammography presents clear advantages in storage and handling of information. Also its higher sensitivity will lead to an earlier detection of anomalies and a decrease in the number of invasive exams and surgeries

2001-05-01

249

Thermoelectrically cooled water trap  

Energy Technology Data Exchange (ETDEWEB)

A water trap system based on a thermoelectric cooling device is employed to remove a major fraction of the water from air samples, prior to analysis of these samples for chemical composition, by a variety of analytical techniques where water vapor interferes with the measurement process. These analytical techniques include infrared spectroscopy, mass spectrometry, ion mobility spectrometry and gas chromatography. The thermoelectric system for trapping water present in air samples can substantially improve detection sensitivity in these analytical techniques when it is necessary to measure trace analytes with concentrations in the ppm (parts per million) or ppb (parts per billion) partial pressure range. The thermoelectric trap design is compact and amenable to use in a portable gas monitoring instrumentation.

2006-02-21

250

Picosecond pulse-conductivity technique applied to study excess-electron reactions in hydrocarbon mixtures  

Energy Technology Data Exchange (ETDEWEB)

To measure electron reactions on a picosecond timescale the investigators developed a picosecond pulse-conductivity technique, which makes use of the electron fine-structure pulses of our LINAC (pulse width 25 vs FWHM) to produce excess electrons and now detects changes in sample conductance under optimum conditions with an instrumental response of 18 ps. This resolution is in agreement with a theoretical estimate. This technique has been successfully applied to study excess electron reactions in solvents covering a mobility range from 0.24 to 100 cm/sup 2/V/sup -1/s/sup -1/; extension to lower mobility liquids seem possible.

1983-01-01

251

Mississippi exploration field trials using microbial, radiometrics, free soil gas, and other techniques  

Energy Technology Data Exchange (ETDEWEB)

The Mississippi Office of Geology has conducted field trials using the surface exploration techniques of geomicrobial, radiometrics, and free soil gas. The objective of these trials is to determine if Mississippi oil and gas fields have surface hydrocarbon expression resulting from vertical microseepage migration. Six fields have been surveyed ranging in depth from 3,330 ft to 18,500 ft. The fields differ in trapping styles and hydrocarbon type. The results so far indicate that these fields do have a surface expression and that geomicrobial analysis as well as radiometrics and free soil gas can detect hydrocarbon microseepage from pressurized reservoirs. All three exploration techniques located the reservoirs independent of depth, hydrocarbon type, or trapping style.

1995-12-31

252

Coal-mine-hazard detection using in-seam ground-penetrating-radar transillumination. Report of Investigations/1987  

Energy Technology Data Exchange (ETDEWEB)

The Bureau of Mines recently completed peliminary studies to demonstrate the feasibility of using Ground-Penetrating Radar (GPR) for in-seam hazard detection. Investigations included air and coal tests for the purpose of checking equipment accuracy, coal penetration, and other factors such as the effects of receiver orientation. Further investigations involved using both a short pulse and a new prototype synthetic-pulse system to locate a clay vein in a coal seam using transillumination. Data were gathered on multiple travel paths, and a back-projection processing technique was then used to create a tomographic image using the calculated velocities. A computer model of the same coal seam was subsequently processed using the same tomogrpahic technique, and the results were compared with those of the actual data. Results of these preliminary studies show that GPR is feasible for use in in-seam hazard ...

1987-01-01

253

Preparatory Signal Detection for Annex I Countries under the Kyoto Protocol. A Lesson for the Post-Kyoto Policy Process  

Energy Technology Data Exchange (ETDEWEB)

The focus of this study is on the preparatory detection of uncertain net greenhouse gas (GHG) emission changes (also termed emission signals) under the Kyoto Protocol. The crucial question to be addressed is: How well do we need to know net emissions if we want to detect a specified emission signal after a given time? No restrictions exist as to what concerns the net emitter, which may be any GHG source or sink. Annex I countries are chosen as net emitters, simply for reasons of data availability and because of the excellent possibility of comparing net emitters (inter-country comparison). The countries' emissions - in an increasing number of cases even their uncertainties - are available permitting the application of preparatory signal detection techniques, which are suited to address the aforementioned question. We currently discuss four hierarchically-ordered detection ...

2004-06-14

254

Evaluation of calcification in pulmonary nodules using bone images obtained with single exposure energy subtraction  

Energy Technology Data Exchange (ETDEWEB)

Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: (1) conventional radiography (CXR), (2) low kV conventional radiography (Low), (3) Fuji computed radiography (FCR), (4) bone images with conventional singles exposure energy subtraction (ES) and (5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, images of 42 lung nodules (21 calcified lung nodules and 21 ...

1995-08-01

255

Evaluation of calcification in pulmonary nodules using bone images obtained with single exposure energy subtraction  

International Nuclear Information System (INIS)

Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: 1) conventional radiography (CXR), 2) low kV conventional radiography (Low), 3) Fuji computed radiography (FCR), 4) bone images with conventional singles exposure energy subtraction (ES) and 5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, images of 42 lung nodules (21 calcified lung nodules and 21 ...

1995-01-01

256

Adaptive Waveform Correlation Detectors for Arrays: Algorithms for Autonomous Calibration  

Energy Technology Data Exchange (ETDEWEB)

Waveform correlation detectors compare a signal template with successive windows of a continuous data stream and report a detection when the correlation coefficient, or some comparable detection statistic, exceeds a specified threshold. Since correlation detectors exploit the fine structure of the full waveform, they are exquisitely sensitive when compared to power (STA/LTA) detectors. The drawback of correlation detectors is that they require complete knowledge of the signal to be detected, which limits such methods to instances of seismicity in which a very similar signal has already been observed by every station used. Such instances include earthquake swarms, aftershock sequences, repeating industrial seismicity, and many other forms of controlled explosions. The reduction in the detection threshold is even greater when the techniques are applied to arrays since stacking can be ...

2009-07-23

257

Supervision monitoring for radiation environment around Daya Bay and Lingao nuclear power stations  

International Nuclear Information System (INIS)

This paper systematically introduces the supervision monitoring for radiation environment around the Guangdong Daya Bay and Ling Ao nuclear power station by the Guangdong Environmental Radiation Research and Monitoring Center. It includes the monitoring plan, methods, quality assurance, main results and conclusions. The results show that: (1) The gas discharge have not caused any detectable impacts to the terrestrial and atmospheric environment since their operation; (2) "1"1"0"mAg could only be detected in seawater in the West Daya Bay in 1995 and 1997 and in sediments in 1997. The maximum annual average in seawater was 3.1 Bq/m"3, annual average of "1"1"0"mAg in sediments was 1.0 Bq/kg(dry). But it was always detectable in pearl oyster, gulfweed and cuttlefish in the West Daya Bay. The "1"1"0"mAg concentrations in halobios were relatively higher in 1994, 1996 and 1997. The maximum ...

2004-05-01

258

DNA rearrangements from #gamma#-irradiated normal human fibroblasts preferentially occur in transcribed regions of the genome  

International Nuclear Information System (INIS)

Full text: DNA rearrangement events leading to chromosomal aberrations are central to ionizing radiation-induced cell death. Although DNA double-strand breaks are probably the lesion that initiates formation of chromosomal aberrations, little is understood about the molecular mechanisms that generate and modulate DNA rearrangement. Examination of the sequences that flank sites of DNA rearrangement may provide information regarding the processes and enzymes involved in rearrangement events. Accordingly, we developed a method using inverse PCR that allows the detection and sequencing of putative radiation-induced DNA rearrangements in defined regions of the human genome. The method can detect single copies of a rearrangement event that has occurred in a particular region of the genome and, therefore, DNA rearrangement detection does not require survival and continued multiplication of ...

2003-08-17

259

Analysis of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For detector position out side the RB containment, the travel time for ...

2005-11-23

260

Self-assessment of current knowledge in nuclear medicine (second edition)  

Energy Technology Data Exchange (ETDEWEB)

In this updated second edition, the order of contents of the textbook has been reorganized. It has been divided into main parts: Basic Science and Clinical Nuclear Medicine. Basic Science, Part I, encompasses basic physics, radiation protection, interaction of radiation with matter and radiation detection, imaging, nuclear pharmacy, and radiation biology. Part II, Clinical Nuclear Medicine, covers the central nervous system, bone, gastroenterology (liver/spleen), cardiovascular system, pulmonary system, genitourinary system, thyroid and endocrine systems, gallium studies, radioassay, hematology, and therapy. The total number of pages of the current edition is increased to 250 from the 213 of the first edition but there are fewer questions because those in the basic science area have been carefully selected to 60 of the original 98 questions. Compared with the previous edition, there ...

1981-01-01

261

Salmonella radicidation of poultry carcasses  

International Nuclear Information System (INIS)

This thesis reports investigations using gamma-radiation to decontaminate poultry carcasses. The application to foods of doses of ionizing radiation sufficient to reduce the number of viable specific non-sporeforming pathogenic microorganisms so that none is detectable in the treated food by any standard method is termed radicidation. The doses used in this study were at such a level that no undesirable or unfavourable side-effects occurred. The effects of these doses were studied on salmonellae and other microorganisms present in, or associated with poultry carcasses and in liquid and on solid culture media as well. Decimal reduction (D_1_0) values were estimated. These represent the dose (kGy) required to achieve a reduction in initial colony count from N_0 to 0.1 N_0. Together with the estimation of the numbers of Salmonella present per carcass the data were used to predict the effect of an ionizing ...

2005-09-22

262

Recurrent plot analysis of discharge sequences in tracking test of polybutylene polymers  

Energy Technology Data Exchange (ETDEWEB)

Polymers are required to use in radiation environments as insulation materials. However, they often suffer from tracking failure. There is an increasing demand to evaluate radiation effects on dielectric performance. This paper presents a recurrence plot (RP) approach to analyse surface discharge sequences of gamma-ray irradiated polymer materials based on tracking test. Studying the non-linear characteristics of discharge sequences can assist in understanding the underlying mechanism of the discharge process. Discharge sequences of the test are extended to m-dimensional phase space by using the phase space reconstructed method. As test samples, polybutylene terephthalate (PBT) and polybutylene naphthalate (PBN) were irradiated to 100 kGy and then up to 1 MGy with a dosage rate of 10 kGy h{sup -1} by using a {sup 60}Co gamma source. The tracking tests were carried out according to the test method described in IEC60112. It is found that the RPs ...

2008-10-07

263

Low dose effects - is the fear more dangerous than the radiation?  

Energy Technology Data Exchange (ETDEWEB)

The use of hypothesis which assumes a dose / harmful effect relationship without a limit allows the calculation of risks attributable to doses too small to produce detectable, harmful biological effects. The daughter product of this hypothesis is ALARA concept which requires that the dose received is kept as low as reasonably achievable. This concept of prudent avoidance is generally accepted by international radiation protection organisations and universally applied by radiation health professionals. The acceptance of a hypothesis which assumes that a single nuclear event can cause carcinogenesis, has generated levels of anxiety which may have resulted in significant detriment to those possibly exposed to ionising radiation. The anxiety generated may have caused more detriment and a higher death rate than the worst case ` theoretical` value calculated using the Linear or Quadratic Linear Hypothesis. ...

1996-01-01

264

Behavioral effects of exposure to the TEMPO high-power microwave system. Interim report, January-June 1987  

Energy Technology Data Exchange (ETDEWEB)

Safety standards for exposure to radiofrequency radiation must be based upon biologic consequences of exposure to such environments. Behavioral-based measures are considered to be the most-sensitive indices of biological effects. Current safety guidelines are based upon average power density and may not be relevant to the high-peak-power, short pulse width microwave radiation produced by newly developed high peak power microwave sources. The effects of exposure to high-peak-power radiation on reflexive responding and motor function in Fischer 344/N rats were assessed by measuring startle and general activity, and disruption of on-going performance of a rotarod task, respectively. The emitter used was the TEMPO repeat pulse axially extracted vircator. Exposure to single pulses resulted in significant startle responses. Exposure to 1 pps for 10 s produced significant alterations in baseline activity and marked disruption of ...

1988-03-01

265

Ultrasonic Phased Array Implementation of the Inside Diameter Creeping Wave Sizing Method  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a technique for implementing the ultrasonic inside diameter (ID) creeping wave technique for detection and sizing ID connected defects using a phased array ultrasonic system. The technique uses multiple focal laws to produce the examination modes. The first focal law is designed to create a shear wave nominally at the critical angle for mode conversion to a longitudinal wave at the ID of a part, thus creating a creeping wave. This focal law is focused at the ID to improve sensitivity. The rest of the laws are designed to create tandem sound paths that progress up a vertical surface directly above the focal point of the creeping wave generation point. When a defect on the inner surface is detected with the creeping wave, the height of the defect can be measured from the response of a set of tandem laws without readjusting the position of the probe. Results from ...

2006-05-01

266

Microwave dissolution of plant tissue and the subsequent determination of trace lanthanide and actinide elements by inductively coupled plasma-mass spectrometry  

Energy Technology Data Exchange (ETDEWEB)

Recently there has been much concern with the ability of plants to uptake heavy metals from their surroundings. With the development of instrumental techniques with low detection limits such as inductively coupled plasma-mass spectrometry (ICP-MS), attention is shifting toward achieving faster and more elegant ways of oxidizing the organic material inherent in environmental samples. Closed-vessel microwave dissolution was compared with conventional methods for the determination of concentrations of cerium, samarium, europium, terbium, uranium and thorium in a series of samples from the National Institute of Standards and Technology and from fields in Idaho. The ICP-MS technique exhibited detection limits in parts-per-trillion and linear calibration plots over three orders of magnitude for the elements under study. The results obtained by using nitric acid and hydrogen peroxide in a microwave digestion ...

1997-08-01

267

Magnified x-ray phase imaging using asymmetric Bragg reflection: Experiment and theory  

International Nuclear Information System (INIS)

X-ray imaging using asymmetric Bragg reflection in the hard x-ray regime opens the way to improve the spatial resolution limit below 1 #mu#m by magnifying the image before detection, simultaneously providing a strong phase contrast. A theoretical formalism of the imaging process is established. Based on this algorithm, numerical simulations are performed and demonstrate that both Fresnel propagation and Bragg diffraction contribute to contrast formation. The achievable resolution of this technique is investigated theoretically; the results obtained can be used to improve future experimental setups. Furthermore, the minimum detectable phase gradient is estimated, for comparison with other phase sensitive imaging techniques. Results from biological objects demonstrate that the technique is viable for imaging both in two and three dimensions. Refraction contrast images are extracted ...

2006-08-01

268

Depth profile analysis on the nanometer scale by a combination of electron probe microanalysis (EPMA) and focused ion beam specimen preparation (FIB)  

International Nuclear Information System (INIS)

Electron probe microanalysis (EPMA) offers high sensitivity and high accuracy in quantitative measurements of chemical compositions and mass coverages. Owing to the low detection limits of the wavelength-dispersive technique, monolayers with mass coverages of about 0.05 pg cm z can be detected. Assuming a density of 5 g cm--3 this corresponds to a thickness of 0.1 nm. With these advantages in mind, EPMA was extended to depth profile analysis in the sub-micron range using a surface removal technique. The present paper shows how depth profile analysis can be improved by combining EPMA and the focused ion beam (FIB) technique. The focused ion beam system uses a Ga+ ion beam. The ion beam allows the milling of defined geometries on the nanometer scale, so that very shallow bevels with exactly defined angles in relation to the surface can be obtained. Low surface damage is expected due ...

269

Analysis of coupled neutron-gamma radiations by the multigroup Albedo method applied to multilayered slab shieldings  

International Nuclear Information System (INIS)

Full text: The principal nuclear design tools available to the shielding designer include diffusion approximation, transport theory, and Monte Carlo techniques. Full transport theory or Monte Carlo methods are routinely used for shielding analyses, where penetration investigations are more sensitive to directional aspects. However, the aim of this paper is to illustrate the coupled neutron-gamma Albedo method particularly as applied to problems of shielding analysis. The multigroup Albedo method is applied to coupled neutron-gamma radiations considering 'n' neutron energy groups and 'g' gamma energy groups to estimate the probabilities of transmission through, absorption in, and reflection from shieldings composed by multiple material layers, 'm' slabs, in which no fission occurs. In this study, these energy groups were selected in order to minimize upscattering effects of the radiation from lower energy groups to higher ...

270

Design and operation of an apparatus for calorimetric emittance measurements of pipe surfaces  

Energy Technology Data Exchange (ETDEWEB)

A technique for the measurement of the total hemispherical emittance of pipe surfaces is described, and design and operational details are given. The technique is conceptually simple. A long test pipe (e.g., 3.4 m) is mounted concentrically inside a Pyrex glass pipe. The system is evacuated, and the test pipe is heated by means of an electrical resistance heater. Heat transfer from the test pipe to the enclosure is almost solely radiative, allowing an average emittance for the test pipe and the Pyrex pipe and the electrical power input to the heater. By varying the electrical power level, one can measure the test pipe emittance as a function of temperature. By using a simple correction to account for the finite length of the test pipe, one can calculate the results using the simple expression for infinite, concentric cylinders. Results agree with measurements by reflectance techniques and have a nominal ...

1981-10-01

271

Modeling the Galactic CV Distribution for the ChaMPlane Survey  

CERN Document Server

For purposes of designing targeted cataclysmic variable (CV) detection surveys and interpreting results of other projects with many CV detections such as the ChaMPlane Survey, we have created a model of the CV distribution in the Galaxy. It is modeled as a warped, flared exponential disk with a gaussian vertical distribution. Extinction is based on a detailed Galactic dust and gas model. A luminosity function for CVs is also incorporated, based on a smoothed version of published data. We calculate predicted field detection rates as a function of the limiting magnitude expected for the detecting system (i.e. WIYN/Hydra or NOAO 4m/Mosaic). Monte-Carlo techniques are used to assess statistical fluctuations in these rates. We have created maps of the expected CV distribution for the full non-bulge Galactic plane (20

2007-01-01

272

Geometrically anisotropic probes: an improved eddy current technique  

Energy Technology Data Exchange (ETDEWEB)

Geometrically anisotropic eddy current probes are a type of separate function probes especially fit to the detection of defects showing a preferential direction. This kind of flaw induces a coupling between the transmitter and the receiver by guiding eddy currents from the one to the other. On the other hand, this coupling will be almost non-existent in the presence of defects or spurious effects not displaying this geometrical particularity. Basic studies on an elementary two-coil set-up allow the acknowledgment of the intrinsic qualities of such probes: good signal-to-noise ratio, influence field practically constant on the whole defect length, ability to detect bridged defects, insensitivity to lift off. These results can be improved by achieving multicoils probes adapted to different kinds of problems. An application to continuous casting slabs testing yields very interesting results in the detection of cracks, while ...

1987-06-01

273

Particle Detection with drift Chambers  

CERN Document Server

Particle Detection with drift Chambers

2008-01-01

274

Toughness of membranes applied in polymer electrolyte fuel cells  

Energy Technology Data Exchange (ETDEWEB)

Since several years we apply the radiation-grafting technique to prepare polymeric membranes for application in polymer electrolyte fuel cells (PEFCs). Our investigations presented here focus on changes in toughness of these materials after the various synthesis steps and the importance of membrane toughness for their application in PEFCs. (author) 2 figs., 4 refs.

1999-08-01

275

Superspace evaluation of the two-loop effective potential for the O'Raifeartaigh model  

CERN Document Server

All-order spurion-corrected superpropagators and superfield Feynman rules are employed to systematically compute a two-loop corrected effective potential for the O'Raifeartaigh model, that realizes spontaneous supersymmetry breaking. Though the shifted superpropagators are rather nontrivial, superspace techniques may be suitably extended and confirm their efficacy in computing radiative corrections even when supersymmetry breakdown occurs.

2010-01-01

276

Spatiotemporal Analysis of Environmental Radioactivity in Soil around Nuclear Plant  

Energy Technology Data Exchange (ETDEWEB)

Geostatistical techniques make it possible to qualitatively and quantitatively analyze spatiotemporal inherent characteristics of environmental radiation or radioactivity. Spatial patterns and trend analysis of environmental radioactivity, e.g., {sup 137}Cs and {sup 40}K, in soil around nuclear facilities (Kori, Wolsung, Yeonggwang, Uljin, and Daejeon) will be investigated and discussed.

2006-07-01

277

Screen-film-combinations for radiography - present and future spectrum of application  

Energy Technology Data Exchange (ETDEWEB)

From the numbers of radiographs of the different examinations and the total amount of radiological diagnostics in the GDR their possible modification by new imaging techniques is discussed under the aspects of costs and radiation burden. Film-screen-systems are of special importance, because they also will be most frequently used image recording system in future. The importance of their various properties and parameters, methods of determining these parameters as well as future developments are analyzed from the standpoint of practical requirements.

1985-01-01

278

Screen-film-combinations for radiography - present and future spectrum of application  

International Nuclear Information System (INIS)

From the numbers of radiographs of the different examinations and the total amount of radiological diagnostics in the GDR their possible modification by new imaging techniques is discussed under the aspects of costs and radiation burden. Film-screen-systems are of special importance, because they also will be most frequently used image recording system in future. The importance of their various properties and parameters, methods of determining these parameters as well as future developments are analyzed from the standpoint of practical requirements. (author).

279

Microwaves (including RADAR) and radiation protection  

Energy Technology Data Exchange (ETDEWEB)

The Commission of the European Communities has submitted a directive for the protection against microwaves. According to this directive, exposures above the upper limit established for the protection of individuals and the general population are permissible only if the respective individuals are required to submit to occupational medical control. An introductory overview is presented giving information on microwaves, applied techniques and available protective means.

1981-02-01

280

IAEA Co-ordinated Research Program (CRP)  

International Nuclear Information System (INIS)

The Coordinated Research Project is a topical collection of research agreements and contracts. The research contracts are awarded with financial support of about 10-20% of the total contract cost. Among the activities of the project is the organization of consultant group meetings and workshops involving several international experts and representatives of users and developers of border radiation monitoring equipment. The project also supports in coordinating the development of equipment and techniques for up-to-date border monitoring and in establishing of a process for providing nuclear forensics support to member states

2010-05-19

281

Heat transfer  

Energy Technology Data Exchange (ETDEWEB)

Heat transfer has emerged as a leading-edge technology supporting the rapid pace of developments in science and engineering ranging from energy production to electronic cooling. Subjects covered at the 6th UK National Conference on heat transfer held at Edinburgh from 15-16 September 1999 include: convection; boiling and evaporation; condensation; numerical techniques; heat exchangers; radiation and combustion; conduction; two-phase flow and heat transfer augmentation. Fifteen of the papers are abstracted here.

1999-07-01

282

Final Report: Planetary Instrument Definition and Design Program (PIDDP) Support Project  

Energy Technology Data Exchange (ETDEWEB)

The results of Sandia National Laboratories' participation in the NASA Planetary Definition and Design Program are summarized. Areas reported include the characterization of large area cadmium zinc telluride spectrometers and the application of simulation techniques to the prediction of device performance. Also investigated was the response of mercuric iodide devices in the region from 1 to 100 KeV. A literature study to determine the status or radiation damage measurements in room temperature semiconductor devices is also reported.

1999-03-01

283

Radiant emittance of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

An embodiment of a mercury-free fluorescent lamp combines a low pressure rare gas discharges with a phosphor having a quantum efficiency grater than one. The choice of the rare gas depends on a number of factors, one of which is the resonance transition energy. Less demand is placed the quantum efficiency of the phosphor for a lower energy resonance photon. Xenon has the lowest energy resonance transition of the stable rare gases at 8.5 eV (147 nm) and thus is a good candidate to study. The usefulness of a xenon-based discharge depends on the radiant emittance of the discharge at the resonance wavelength of 147 nm. The radiant emittance from a low pressure xenon positive column discharge is measured using two independent techniques. The first relies on the measurement of the resonance level density using absorption techniques. The effective decay rate of the resonance level is calculated using radiation trapping theory. The ...

1994-12-31

284

Real-time neutron monitoring method using an imaging plate  

Energy Technology Data Exchange (ETDEWEB)

A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)

1999-07-01

285

Real-time neutron monitoring method using an imaging plate  

International Nuclear Information System (INIS)

A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)

1999-04-19

286

Authentication of byte sequences  

Energy Technology Data Exchange (ETDEWEB)

Algorithms for the authentication of byte sequences are described. The algorithms are designed to authenticate data in the Storage, Retrieval, Analysis, and Display (SRAD) Test Data Archive of the Radiation Effects and Testing Directorate (9100) at Sandia National Laboratories, and may be used in similar situations where authentication of stored data is required. The algorithms use a well-known error detection method called the Cyclic Redundancy Check (CRC). When a byte sequence is authenticated and stored, CRC bytes are generated and attached to the end of the sequence. When the authenticated data is retrieved, the authentication check consists of processing the entire sequence, including the CRC bytes, and checking for a remainder of zero. The error detection properties of the CRC are extensive and result in a reliable authentication of SRAD data.

1991-06-01

287

The use of "1"3"1I-radioiodine in diagnostic and treatment: estimated risk in Guanabara  

International Nuclear Information System (INIS)

The "1"3"1-radioiodine use in Guanabara area, during 1972-1973, is analysed. References are made to the radiation levels delivered to thyroid, bone marrow and gonads in a population of 27000 people examined by tracer techniques, 190 submitted to hyperthyroidism treatment and 50 treated for thyroid cancer. The pertinent literature gives some data concerning radiation induced cancer (leukaemia and thyroid cancer). By this, it was possible to estimate the probability of tumour occurrence in that population, assuming a linear relationship between dose and effect. The conclusions are the followings: 1 - there are many duties in this field at the present; 2 - the leukaemia incidence related to the 131-radioiodine use is negligible, either in diagnostic or therapeutic modalities; 3 - the possibility of thyroid tumors induced by radiation is real, specially in hyperthyroidism treatment; 4 - the use of tracer ...

288

Mercury-free fluorescent lighting  

Energy Technology Data Exchange (ETDEWEB)

A brief comparative review of possible mercury free fluorescent lighting technologies is presented, including rare-gas positive column discharges, molecular discharges, and dielectric barrier discharges. Detailed experimental results on xenon positive column discharges will then be considered. In order to judge whether xenon-based discharges are a viable UV source it is necessary to measure the radiant emittance (power per unit area) for the vacuum ultraviolet (VUV) resonance xenon emission at 147 nm. Two techniques to determine the VUV radiant emittance have been developed and applied to xenon discharges. One method combines the measured resonance level density using absorption spectroscopy and a calculation of the trapped decay rate for the resonance radiation to arrive at the radiant emittance at 147 nm. A second method utilizes a direct measurement of the radiance (power per unit area per unit solid angle) at 147 nm using a calibrated VUV ...

1996-05-01

289

Alteration of the enterohepatic recirculation of bile acids in rats after exposure to ionizing radiation  

Energy Technology Data Exchange (ETDEWEB)

The aim of this work was to study acute alterations of the enterohepatic recirculation (EHR) of bile acids 3 days after an 8-Gy radiation exposure in vivo in the rat by a washout technique. Using this technique in association with HPLC analysis, the EHR of the major individual bile acids was determined in control and irradiated animals. Ex vivo ileal taurocholate absorption was also studied in Ussing chambers. Major hepatic enzyme activities involved in bile acid synthesis were also measured. Measurements of bile acid intestinal content and intestinal absorption efficiency calculation from washout showed reduced intestinal absorption with significant differences from one bile acid to another: absorption of taurocholate and tauromuricholate was decreased, whereas absorption of the more hydrophobic taurochenodeoxycholate was increased, suggesting that intestinal passive diffusion was enhanced, whereas ileal active transport ...

2004-02-01

290

Irradiating the groin nodes without breaking a leg: A comparison of techniques for groin node irradiation  

International Nuclear Information System (INIS)

The purpose of this study was to determine the optimal technique for delivering postoperative radiotherapy for vulvar cancer and other tumors requiring treatment of the inguinal nodes. This project compared tumor coverage and normal tissue sparing for the 5 main radiotherapy techniques that are used to treat vulvar cancer. The intensity-modulated radiation therapy (IMRT) plan was undesirable because it resulted in an excessive dose to portions of the central pelvic structures. The photon thunderbird with skin match was unacceptable because it underdosed a portion of the groin region. The electron thunderbird was ideal for thin patients but was not applicable for most patients because of excessive dose to the skin and subcutaneous tissues. The photon through-and-through and the photon thunderbird with deep match were acceptable in most situations. In thin patients, where the depth of the inguinal vessels is less than 3 cm, ...

291

Use of radiosensitivity to identify irradiated fresh poultry products  

International Nuclear Information System (INIS)

Microbiological comparison between irradiated and non-irradiated foodstuff has been studied for a long time as a way to detect whether a foodstuff has been irradiated or not. Generally, the proposed methods are based on the fact that ionization select species of bacteria which are recognized to be radioresistant. So reduction or elimination of known radiation sensitive microbes from the normal endogenous microflora could give an indication that the foodstuff has been irradiated, predominance of known radioresistant bacteria should be another indication. In the present work, we try to develop a test based on the radiosensitivity of the bacteria independently of their place. These first experiments show that the determination of radiosensitivity of strains isolated from a product or even of global radioresistance of mesophilic microflora could indicate if this product has been previously submitted to ionizing radiations. (4 ...

1990-02-14

292

Time Characterization of High Density Gas Jet from a Pulsed Supersonic Nozzle via Laser Produced Plasma  

International Nuclear Information System (INIS)

A high-density gas jet supersonic nozzle is reported in this paper. The jitter and actuation time of the nozzle is determined by the pin discharge and laser spark radiation respectively. The jitter time of the nozzle is within 10 ?s with the backing pressure as high as 25 bar. With a nanosecond laser pulse focused on the gas jet about 1 mm below the nozzle, the actuation time is calculated to be about 15 ms by detecting the laser produced spark radiation, which reveals the existence of the gas jet and the relative gas density evolving with time. Consequently the gas density is estimated to be well above 1019 cm-3, compared with theoretical simulations from the nozzle parameters.

2006-07-01

293

Superconducting strip detectors as position sensitive particle detectors  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of using of current-biased superconducting strips for radiation detection is investigated. Narrow Ta strips are exposed to 5.5 MeV [alpha]-particle radiation and the rise-time of the induced voltage pulses is measured as function of temperature and bias current. The rise-time of the voltage signal strongly depends on the site on the strip which is hit by the [alpha]-particle. In order to determine the spatial resolution of a superconducting strip detector, position-sensitive measurements were performed. The maximum lateral resolution estimated so far is 25[mu]m in a 7[mu]m wide, 340 nm thick and 0.6 mm long Ta-strip. (orig.)

1994-02-01

294

Point defects in dilute nitride III-N-As and III-N-P  

International Nuclear Information System (INIS)

We provide a brief review of our recent results from optically detected magnetic resonance studies of grown-in non-radiative defects in two most important dilute nitride systems-Ga(In)NAs grown on GaAs substrates and Ga(Al,In)NP grown on Si and GaP substrates. These results have led to the identification of defect complexes in the alloys, involving intrinsic defects such as As_G_a antisites and Ga_i self-interstitials. They have also shed light on formation mechanisms of the defects and on their role in non-radiative carrier recombination that is harmful to the performance of potential optoelectronic and photonic devices based on these dilute nitrides.

2006-04-01

295

Gamma-rays and neutrinos from the pulsar wind nebulae  

Energy Technology Data Exchange (ETDEWEB)

We construct the time-dependent radiation model for the pulsar wind nebulae (PWNe), assuming that leptons are accelerated in resonant scattering with heavy nuclei, which are injected into the nebula by the pulsar. The equilibrium spectra of these particles inside the nebula are calculated taking into account their radiation and adiabatic energy losses. The spectra of {gamma}-rays produced by these particles are compared with the observations of the PWNe emitting TeV {gamma}-rays and predictions are made for the expected {gamma}-ray fluxes from other PWNe. Expected neutrino fluxes and neutrino event rates in a 1 km{sup 2} neutrino detector from these nebulae are also calculated. It is concluded that only the Crab Nebula can produce a detectable neutrino event rate in the 1 km{sup 2} neutrino detector. Other PWNe can emit TeV {gamma}-rays on the level of a few percent of that observed from the Crab Nebula.

2005-08-01

296

Fractionation of combined heat and radiation in asynchronous CHO cells. II. The role of cell-cycle redistribution  

Science.gov (United States)

Asynchronous Chinese hamster ovary (CHO) cells treated with conditioning hyperthermia (10 min at 45/sup 0/C) followed immediately by x irradiation with 4 Gy at room temperature display a decreased radiation response when either irradiated, or heated and irradiated again 24 h later. In addition, conditioning by 4 Gy of x radiation alone followed at 24 h by the combined heat and radiation treatment als resulted in a larger radiation D/sub 0/. Since the differential cell-cycle responses to heat- and x-ray-induced lethality are well established for CHO cells, the potential role of cell-cycle redistribution in the observed radiation desensitization was investigated by flow cytometry. At 24 h after the combined treatment, the fraction of the cells found in the G/sub 2/ + M portion of the DNA histograms was about three times that of the controls and there was a concomitant reduction in ...

1979-11-01

297

High order statistical signatures from source-driven measurements of subcritical fissile systems  

Energy Technology Data Exchange (ETDEWEB)

This research focuses on the development and application of high order statistical analyses applied to measurements performed with subcritical fissile systems driven by an introduced neutron source. The signatures presented are derived from counting statistics of the introduced source and radiation detectors that observe the response of the fissile system. It is demonstrated that successively higher order counting statistics possess progressively higher sensitivity to reactivity. Consequently, these signatures are more sensitive to changes in the composition, fissile mass, and configuration of the fissile assembly. Furthermore, it is shown that these techniques are capable of distinguishing the response of the fissile system to the introduced source from its response to any internal or inherent sources. This ability combined with the enhanced sensitivity of higher order signatures indicates that these techniques will be of ...

1998-04-01

298

Experience and recent developments in nuclear forensics at the Institute of Isotopes  

International Nuclear Information System (INIS)

Full text: Based on experience with nuclear material confiscated in Hungary from illicit trafficking activities in the nineties it has been decided that traditional gamma-spectrometry should be complemented by destructive analytical techniques. The 17/1996 (I. 31.) Korm. Governmental Decree delegated the identification, categorization and characterization tasks to the Institute of Isotopes, Budapest. Routine gamma-spectrometric methods have been further developed aiming at the i) age (production date) determination of seized samples and complete (nondismountable) uranium-bearing items (such as fresh fuel bundles and fission chambers) by HRGS technique, ii) improvement of measurement accuracy and reliability. Starting in 2005 mass spectrometry (ICP-SFMS) and scanning electron microscopy have been implemented to characterize nuclear samples in more detail and to analyze environmental samples both for isotopic and elemental composition focusing on ...

299

Review of passive heat transfer augmentation techniques  

Energy Technology Data Exchange (ETDEWEB)

Heat transfer augmentation techniques (passive, active or a combination of passive and active methods) are commonly used in areas such as process industries, heating and cooling in evaporators, thermal power plants, air- conditioning equipment, refrigerators, radiators for space vehicles, automobiles, etc. Passive techniques, where inserts are used in the flow passage to augment the heat transfer rate, are advantageous compared with active techniques, because the insert manufacturing process is simple and these techniques can be easily employed in an existing heat exchanger. In design of compact heat exchangers, passive techniques of heat transfer augmentation can play an important role if a proper passive insert configuration can be selected according to the heat exchanger working condition (both flow and heat transfer conditions). In the past decade, several ...

2004-12-01

300

Pixel-based and object-oriented change detection analysis using high-resolution imagery  

Energy Technology Data Exchange (ETDEWEB)

The high spatial resolution of state-of-the-art commercial satellite imagery provides a good basis for recognising and monitoring even small-scale structural changes within nuclear facilities and for planning of routine and/or challenge inspections of nuclear sites. Despite the advantages of the improved spatial resolution some problems exist that may make the interpretation of the changes more difficult: Firstly, the results of the change analysis can be very complex and unclear at a glance. Secondly, shadow formation and off-nadir images due to different sensor and solar conditions at the acquisition times can cause false signals or overlap real changes. In view to the fast-growing amount of data from different sensor types there are then some requirements of an effective change detection procedure for safeguards purposes: i. The techniques involved should possess a certain amount of robustness in terms of small misregistration errors, ...

2003-05-01

301

Retrospective individual dosimetry using luminescence and EPR after radiation accidents  

International Nuclear Information System (INIS)

In areas where radiation dose monitoring has not been performed, it is essential to use material available in the environment be able to rapidly assess doses to individuals for immediate emergency medical care or for general estimation of the radiological consequences. It was shown that certain types of telephone cards containing microchips have the potential to be used as individual radiation dosimeters in emergency situations to detect doses over 250 mGy by luminescence measurements. In order to understand the dosimetric properties of chip cards, the components obtained from INFINIEON Company at various stages of production were used for luminescence measurements. It is found that the protecting layer used above the chips so called 'globe top' is the main source of radiation induced signal in chip cards. The globe top produced by INFINIEON at that stage is found to contain SiO2 and Epoxy. In order to ...

302

Development of fire simulation models for radiative heat transfer and probabilistic risk assessment  

Energy Technology Data Exchange (ETDEWEB)

An essential part of fire risk assessment is the analysis of fire hazards and fire propagation. In this work, models and tools for two different aspects of numerical fire simulation have been developed. The primary objectives have been firstly to investigate the possibility of exploiting state-of-the-art fire models within probabilistic fire risk assessments and secondly to develop a computationally efficient solver of thermal radiation for the Fire Dynamics Simulator (FDS) code. In the first part of the work, an engineering tool for probabilistic fire risk assessment has been developed. The tool can be used to perform Monte Carlo simulations of fires and is called the Probabilistic Fire Simulator (PFS). In Monte Carlo simulation, the simulations are repeated multiple times, covering the whole range of variability of the input parameters and thus resulting in a distribution of results covering what can be expected in reality. In practical applications, advanced ...

2008-07-01

303

In-situ measurement of epithelial tissue optical properties: Development and implementation of diffuse reflectance spectroscopy techniques  

Science.gov (United States)

Cancer is a severe threat to human health. Early detection is considered the best way to increase the chance for survival. While the traditional cancer detection method, biopsy, is invasive, noninvasive optical diagnostic techniques are revolutionizing the way that cancer is diagnosed. Reflectance spectroscopy is one of these optical spectroscopy techniques showing promise as a diagnostic tool for pre-cancer detection. When a neoplasia occurs in tissue, morphologic and biochemical changes happen in the tissue, which in turn results in the change of optical properties and reflectance spectroscopy. Therefore, a pre-cancer can be detected by extracting optical properties from reflectance spectroscopy. This dissertation described the construction of a fiberoptic based reflectance system and the development of a series of modeling studies. This research is aimed at ...

2009-01-01

304

Observation of high-lying weak autoionizing resonances of Ne, and Mg atoms by charge-separated photoion-yield method  

Energy Technology Data Exchange (ETDEWEB)

Doubly-excited 2s{sup -1}2p{sup -1}3pnp autoionizing resonance series of Ne atom as well as autoionizing resonances in the 2s region of Na and Mg atoms have been studied with monochromatized synchrotron radiation. Use of charge-separated photoion-yield method allowed us to detect these weak resonances in a clarified way in the yield curves of doubly-charged ions. The observed resonance states have been interpreted with the help of MCDF calculations, and the decay processes of these resonance states are discussed briefly.

2007-03-01

305

Observation of high-lying weak autoionizing resonances of Ne, and Mg atoms by charge-separated photoion-yield method  

International Nuclear Information System (INIS)

Doubly-excited 2s-12p-13pnp autoionizing resonance series of Ne atom as well as autoionizing resonances in the 2s region of Na and Mg atoms have been studied with monochromatized synchrotron radiation. Use of charge-separated photoion-yield method allowed us to detect these weak resonances in a clarified way in the yield curves of doubly-charged ions. The observed resonance states have been interpreted with the help of MCDF calculations, and the decay processes of these resonance states are discussed briefly.

2007-03-01

306

Nuclear borehole logging using lithium detector assemblies  

International Nuclear Information System (INIS)

A method and apparatus for nuclear borehole logging, and in particular, neutron porosity logging, uses a neutron source, and a pair of spaced lithium detectors, preferably Li"6I crystal or Li"6 doped glass, to detect neutrons emitted from a borehole formation being logged. The spectrum developed by the lithium detectors is processed to remove the gamma ray background radiation and the hydrogen absorption peak, thus allowing a more accurate neutron count. A Gaussian curve is fitted to the neutron peak of the spectrum, the curve eliminating the hydrogen absorption peak. The area under this Gaussian curve represents the neutron count. (author).

1991-11-01

307

Multielement analysis of air samples  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A "2"3"8Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed. (author).

1981-01-01

308

LET-dependence of the trapping parameters in TLD-100 determined with a computerised curve fitting method  

International Nuclear Information System (INIS)

With a computerized curve fitting method the trapping parameters of TLD-100 chips were calculated after #alpha#-, #beta#- and #gamma#-irradiation. The absorption of radiation produces an additional glow peak at 250 deg C, and the dominant one arises at 280 deg C. After the analysis of the glow curves only a little LET-dependence of the trap depths and that of the half widths was detected. The charge densities after irradiation before heating of the taps responsible for the high temperature glow peaks (T>240 deg C) show a LET-dependence. (author).

1985-10-22

309

Gamma Radiation Detectors of the TA-55 Waste Line Monitoring System  

Energy Technology Data Exchange (ETDEWEB)

This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.

1999-06-01

310

Absolute detection efficiency of radiation detecting system for gamma-ray from sources with high activity  

Energy Technology Data Exchange (ETDEWEB)

In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the {sup 137}Cs-source with 10.4 GBq and {sup 60}Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form {sup 137} Cs 1173.23 and 1332.51 keV{sup 60} Co sources, and 14 peaks of {sup 134}Cs and {sup 154}Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that the detection ...

2003-10-01

311

Absolute detection efficiency of radiation detecting system for gamma-ray from sources with high activity  

International Nuclear Information System (INIS)

In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the "1"3"7Cs-source with 10.4 GBq and "6"0Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form "1"3"7 Cs 1173.23 and 1332.51 keV"6"0 Co sources, and 14 peaks of "1"3"4Cs and "1"5"4Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that the detection efficiency of gamma ...

2003-10-01

312

Sensors to detect CO based in SnO. Sensores para detectar CO basados en SnO  

Energy Technology Data Exchange (ETDEWEB)

The development of solid state chemical sensors, and more specifically of gas sensors, is carried out with great strength in the present time since the environmental pollution and the security in work and domestic ambient are problems of great interest and social impact. The main fields of application, are: automobile, domestic sensors, control of industrial process, bio medicine, environment. These chemical sensors are experimenting a great advance because of the advantages they offer, as low cost, simple operation, possibility of measure continuous and ''In situ'' and small size, in contrast with analytical techniques that need complex instrumentation and large size equipments. In the present work, a sensor for CO detecting concentrations as low as 50 p.p.m., is studied showing great interest since this gas is highly toxic even to such a low concentration. (Author)

1993-01-01

313

Progress Report Towards the ICANOE Detector  

CERN Document Server

We present a proposal for a combined ICARUS & NOE general purpose detector, to be installed in Hall B of the Gran Sasso Laboratory.The main scientific goal is the one of elucidating in a comprehensive way the pattern of neutrino $9 masses and mixings, following both (1) the S-KAM results and (2) the predictions on atmospheric neutrinos of the large solution of the Solar Neutrinos deficit. To achieve these goals, the experimental method is based upon the $9 complementary and simultaneous detection of CERN beam (CNGS) and cosmic ray (CR) events. This is made possible because of the complete isotropy of the detection technique. For the currently allowed values of the S-KAM results, both $9 CNGS and cosmic ray data will give independent measurements and provide a precise $(sin^{2}2\\theta; \\Delta m^{2})$ determination rather than a wide band of allowed values. Since we can observe and unambiguously identify $9 $\

1999-01-01

314

Potential of AMS for Quantifying Long-Lived Reaction Products  

International Nuclear Information System (INIS)

Accelerator mass spectrometry (AMS) represents a powerful technique for the detection of long-lived radionuclides through ultra-low isotope ratio measurements. In many cases, counting atoms rather than decays yields much higher sensitivities. The potential of AMS will be demonstrated on typical radionuclides of interest with half-lives between some tens of years up to a hundred million years. The precise measurement of the 27Al(n,2n)26Al excitation function will be exemplified. Lack of information exists for a list of nuclides as pointed out by nuclear data requests. A brief overview on detection limits and some applications for selected long-lived radionuclides is given.

2005-05-24

315

Petroleum hydrocarbons and organic chemicals in ground water -- prevention, detection and restoration: Proceedings. Ground water management: Book 17  

International Nuclear Information System (INIS)

The 1993 Petroleum Hydrocarbons Conference was comprised of 3 days of technical presentations within the following topic areas: pollution prevention and cost control; development of remediation levels; free-phase and dissolved hydrocarbon contamination management; investigation and analysis of petroleum hydrocarbons; applications of computer modeling for remediation; design and implementation of bioventing; design and implementation of air sparging; soil vapor extraction as a remediation technique; and ground water remediation using natural bacteria. In addition, more than 100 leading companies in the ground water and petroleum industries participated in the Conference Exposition in which a variety of equipment and services for preventing, detecting and remediating ground water contaminated by petroleum hydrocarbons and other organic chemicals was showcased. Individual papers have been processed separately for inclusion in the appropriate data ...

1993-11-10

316

Gear fault detection using customized multiwavelet lifting schemes  

British Library Electronic Table of Contents (United Kingdom)

Fault symptoms of running gearboxes must be detected as early as possible to avoid serious accidents. Diverse advanced methods are developed for this challenging task. However, for multiwavelet transforms, the fixed basis functions independent of the input dynamic response signals will possibly reduce the accuracy of fault diagnosis. Meanwhile, for multiwavelet denoising technique, the universal threshold denoising tends to overkill important but weak features in gear fault diagnosis. To overcome the shortcoming, a novel method incorporating customized (i.e., signal-based) multiwavelet lifting schemes with sliding window denoising is proposed in this paper. On the basis of Hermite spline interpolation, various vector prediction and update operators with the desirable properties of biorthog...

2010-01-01

317

Experimental study of neutron noise with criticality safety applications in mind  

Energy Technology Data Exchange (ETDEWEB)

A study has been conducted on the statistics of detected neutrons that leaked from four subcritical reflected, enriched-uranium assemblies, to explore the feasibility of developing a criticality warning system based on neutron noise analysis. Studies were conducted on three possible discriminators, i.e., three signatures that might be used to discriminate among assemblies of various multiplications. The noise analysis techniques studied performed well enough in deeply subcritical situations to deserve testing in an applications environment. They have a good chance of detecting changes in reactivity that are potentially dangerous. One can expect sharpest results when doing comparisons, i.e., when comparing two records, one taken in the past under circumstances known to be normal and one taken now to search for change.

1985-11-01

318

Eddy currents signal processing for steam generator inspection in PWR nuclear power plants  

International Nuclear Information System (INIS)

Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostic system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of these items.

1992-01-01

319

Absolute subcriticality measurement without calibration and detection efficiency dependence by the /sup 252/Cf source-driven noise method  

Energy Technology Data Exchange (ETDEWEB)

The /sup 252/Cf-source-driven noise analysis method determines the subcriticality of a system containing fissionable material from the ratio of cross power spectral densities between the detectors that detect particles from the fission process and between these detectors and an ionization chamber containing a spontaneously fissioning neutron source which provides neutrons to induce fission in the system. This method has two advantages: (1) a calibration is not required and thus subcriticality can be determined from measurements only on the subcritical system of interest, and (2) the subcriticality is independent of the type of detector or its efficiency. These properties of this technique are illustrated by measurements.

1984-01-01

320

Evaluation of indexes for tumor growth and effect of radiation therapy using MRS; Experimental studies on SCCVII tumor bearing mice  

Energy Technology Data Exchange (ETDEWEB)

Changes in the phosphate metabolism of the transplanted SCCVII (squamous cell carcinoma VII) tumor were studied before and after irradiation using in vivo [sup 31]P-magnetic resonance spectroscopy (MRS). Phosphocreatine (PCr), [gamma]-, [alpha]-, [beta]-ATP, inorganic phosphate (Pi), phosphomonoester (PME), and phosphodiester (PDE) were detected in [sup 31]P-MR spectra of tumor tissues. The curve fitting method was employed for calculating each peak of [sup 31]P-MR spectra (PCr, [beta]-ATP, Pi, PME, PDE). The values of PCr, PCr/Pi, [beta]-ATP/Pi and pH decreased in proportion to the growth of tumor, whereas that of Pi, PME and PDE increased. But the changes of [beta]-ATP were minimal in degree. Based on the fact that the ratio of PCr/Pi highly correlated with tumor volume and showed the most remarkable change among various parameters, it might be the useful index for the tumor growth. Because the phospholipid metabolite PME was detected in the ...

1992-03-01

321

Modeling of Fission Neutrons as a Signature for Detection of Highly Enriched Uranium  

Energy Technology Data Exchange (ETDEWEB)

We present the results of modeling intended to evaluate the feasibility of using neutrons from induced fission in highly enriched uranium (HEU) as a means of detecting clandestine HEU, even when it is embedded in absorbing surroundings, such as commercial cargo. We characterized radiation from induced fission in HEU, which consisted of delayed neutrons at all energies and prompt neutrons at energies above a threshold. We found that for the candidate detector and for the conditions we considered, a distinctive HEU signature should be detectable, given sufficient detector size, and should be robust over a range of cargo content. In the modeled scenario, an intense neutron source was used to induce fissions in a spherical shell of HEU. To absorb, scatter, and moderate the neutrons, we place one layer of simulated cargo between the source and target and an identical layer between the target and detector. The resulting neutrons ...

2004-03-09

322

A superconducting solenoidal spectrometer for a balloon-borne experiment  

Energy Technology Data Exchange (ETDEWEB)

The BESS detector is a new type of balloon-borne spectrometer which utilizes various technologies recently developed for collider experiments. The principal scientific objectives include a measurement of cosmic-ray antiproton spectrum, search for anti-nuclei in cosmic radiation, and precise measurements of cosmic-ray primaries. A thin superconducting solenoidal coil produces a uniform magnetic field of 1 T. Cylindrical drift chambers are located inside and outside the coil and perform continuous tracking. The momentum resolution is 0.5% at 1 GeV/c. i.e., the maximum detectable rigidity is 200 GV. Scintillation counter hodoscopes, placed above and below the solenoid, provide timing and dE/dx measurements and trigger generation. The timing resolution is 80 ps/counter. This cylindrical configuration achieves a large geometrical acceptance of 0.35 m{sup 2} sr which is essential to detect rare cosmic-ray particles. In order to ...

2000-03-21

323

Matrix-assisted laser desorption fourier transform mass spectrometry for biological compounds  

Science.gov (United States)

The recent development of matrix-assisted UV laser desorption (LD) mass spectrometry has made possible the ionization and detection of extremely large molecules (with molecular weights exceeding 100,000 Daltons). This technique has generated enormous interest in the biological community for the direct examination of large peptides and oligonucleotides. Although this matrix-assisted ionization method has been developed and used almost exclusively with time-of-flight (TOF) mass spectrometers, research is currently in progress to demonstrate this technique with trapped ion mass spectrometers, such as Fourier transform ion cyclotron resonance mass spectrometry (FTMS). The potential capabilities of FTMS for wide mass range, high resolution measurement, and ion trapping experiments suggest that this instrumental technique should be useful for the detailed structural characterization of large ions generated by ...

1990-01-01

324

Fiscal 1998 industrial science and technology R and D project. Research report on R and D of genome informatics technology (Development of stable oil supply measures using complex biosystem); 1998 nendo genome informatics gijutsu kenkyu kaihtsu seika hokokusho. Fukugo seibutsukei riyo sekiyu antei kyokyu taisaku kaihatsu  

Energy Technology Data Exchange (ETDEWEB)

This report describes the fiscal 1998 result on development of genome informatics technology. As comparative analysis technique of genes, the combination of electrophoresis and PCR was used. For improvement of the throughput and reproducibility of the technique, module- shuffling primers were used, and the multi(96)-arrayed capillary fragment analyzer was devised. The system detecting SNPs rapidly was also developed successfully. As analysis technology of DNA sequence by use of triple- stranded DNA formation, study was made on construction of long cDNA libraries, selective subtraction of specific sequences from libraries, and the basic technology of homologous cloning. Study was also made on each reaction step of IGCR technique for fast analysis, and specifications of a fluorescence transfer monitor. As modeling technique of genetic sequence information, the simulation model was ...

1999-03-01

325

Data Stream Clustering: Challenges and Issues  

CERN Document Server

Very large databases are required to store massive amounts of data that are continuously inserted and queried. Analyzing huge data sets and extracting valuable pattern in many applications are interesting for researchers. We can identify two main groups of techniques for huge data bases mining. One group refers to streaming data and applies mining techniques whereas second group attempts to solve this problem directly with efficient algorithms. Recently many researchers have focused on data stream as an efficient strategy against huge data base mining instead of mining on entire data base. The main problem in data stream mining means evolving data is more difficult to detect in this techniques therefore unsupervised methods should be applied. However, clustering techniques can lead us to discover hidden information. In this survey, we try to clarify: first, the different problem ...

2010-01-01

326

Status of the WAND (Waste Assay for Nonradioactive Disposal) project as of July 1997  

Energy Technology Data Exchange (ETDEWEB)

The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform the data analysis. WAND system minimum detectable activities (MDAs) for point sources ...

1998-03-01

327

Boron-Lined Multichamber and Conventional Neutron Proportional Counter Tests  

Energy Technology Data Exchange (ETDEWEB)

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. These technologies are: 1) Boron ...

2010-09-07

328

Molecular events involved in ionizing radiation induced skin carcinogenesis  

International Nuclear Information System (INIS)

The process of mouse skin tumor formation is subdivided into three operational stages. These stages include initiation, promotion and progression. Ionizing radiation has been found to be a weak initiating agent in the production of malignant squamous cell carcinomas, a complete carcinogen and an agent effective in causing tumor progression. Four skin tumor histologies have been seen with ionizing radiation: benign papillomas, squamous (SCC) and basal (BCC) cell carcinomas and fibrosarcomas. Distinct non-ras transforming genes have been detected in radiation initiated SCCs. A benign papilloma cell line (308) was used as a model system to study ionizing radiation induced progression. A variant 308 cell line (308 10 Gy 5) derived by irradiation of the parental 308 cell has been characterized. The 308 10 Gy 5 cells unlike the parental 308 cells from malignant tumors in athymic nude mice ...

329

Metabolic effects of microwave radiation and convection heating on human mononuclear leukocytes. Final report, January 1985-May 1986  

Energy Technology Data Exchange (ETDEWEB)

Investigated here were the effects of microwave (MW) radiation (2450-MHz, continuous-wave, mean specific absorption rate of 103.5 + or - 4.2 W/kg) and convention heating on the nonphosphorylating oxidative metabolism of human peripheral mononuclear leukocytes (96% lymphocytes, 4% monocytes) at 37 C. Metabolic activity, determined by chemiluminescence (CL) of cells challenged with luminol (5-aminO-2, 3-dihydro-1, 4-phthalazinedione) linked to bovine serum albumin, was detected with a brightness photomer. A significant stimulation after after MW exposure (p < 0.005) over total CL of matched 37 C-incubator controls was observed. A similar degree of stimulation, compared to incubator controls, was also detected after sham treatment. No significant difference existed between changes in total CL or stimulation indices of the MW and sham-exposed groups. Exposure to MW radiation, under normothermic (37 + or ...

1986-01-01

330

Study of X-ray filter and peak kilovoltage in Fuji computed radiography in regard to the detection of simulated pulmonary nodules  

Energy Technology Data Exchange (ETDEWEB)

To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that (1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; (2) approximately equal detection ...

1994-10-01

331

Study of X-ray filter and peak kilovoltage in Fuji computed radiography in regard to the detection of simulated pulmonary nodules  

International Nuclear Information System (INIS)

To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that 1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; 2) approximately equal detection ...

1994-01-01

332

Detection of basepair substitution mutation at a frequency of 1 x 10(-7) by combining two genotypic selection methods, MutEx enrichment and allele-specific competitive blocker PCR.  

Science.gov (United States)

The detection of rare mutations has many important applications, including risk assessment of drugs and chemicals, measuring environmental exposures to genotoxins, and cancer cell detection. A sensitive genotypic selection method has been developed that combines two different mutant allele selection techniques, MutEx enrichment and allele-specific competitive blocker PCR (ACB-PCR). This method was developed and evaluated for the detection of a CAA --> AAA mutation at codon 61 of the mouse H-ras gene. The MutEx enrichment is based on MutS binding to a mismatched basepair in heteroduplex DNA. The bound MutS protects the mutant allele from degradation during subsequent exonuclease treatment. ACB-PCR preferentially amplifies a mutant allele in a PCR reaction using a primer that has more mismatches to the wild-type allele than the mutant allele. By combining these two approaches, the codon 61 mutation was ...

1998-01-01

333

Assessment of arterial tumor vascularity in small hepatocellular carcinoma. Comparison between color Doppler ultrasonography and radiographic imagings with contrast medium: dynamic CT, angiography, and CT hepatic arteriography  

Energy Technology Data Exchange (ETDEWEB)

Hepatocellular carcinoma (HCC) is characterized by tumor vascularization from the hepatic artery. The objective of our work was to compare color Doppler ultrasonography (CDU), including power Doppler ultrasonography (PDU) with radiographic imagings with contrast medium in regard to the detection of the arterial tumor vascularity of small hepatocellular carcinomas (HCC). We examined 42 small HCC lesions 2 cm or less in diameter in 37 patients for arterial tumor vascularity by conventional CDU, PDU, dynamic computed tomography (dCT), digital subtraction angiography (DSA), and CT hepatic arteriography (CTA). Color images were detected in 25 (59.5%) and 28 (66.7%) of the 42 lesions with conventional CDU and PDU, respectively, and tumor vascularity was detected in 26 (61.9%) by dCT, 23 (54.8%) by DSA, and 29 (69.0%) by CTA. Tumor vascularity could be detected in 51.9% by PDU and CTA, more than by ...

2000-10-01

334

Measurements of K-shell x-ray production cross sections and K to L and M-shell radiative vacancy transfer probabilities for Nd, Eu, Gd, Dy and Ho at excitation with 59.5 keV photons in an external magnetic field  

International Nuclear Information System (INIS)

The effect of the #+-# 0.75 T external magnetic field on the K_#alpha#_1, K_#alpha#_2, K_#beta#_'_1 and K_#beta#_'_2 x-ray production cross sections and radiative vacancy transfer probabilities from K-shell to L2 and L3 subshells and M-shell for ferromagnetic Nd, Gd and Dy and paramagnetic Eu and Ho have been investigated, using the 59.5 keV incident photons. K-shell fluorescence yields and K x-ray intensity ratios for these elements have been determined in the external magnetic field also. The K x-rays from different targets were detected using a high-resolution Si(Li) semiconductor detector. For B = 0, the present experimental results were compared with the experimental and theoretical data in the literature. The results show that K-shell fluorescence parameters such as photoionization cross section, fluorescence yield, radiation rates, vacancy transfer probabilities and spectral linewidth can change owing to the applied ...

2006-06-19

335

Large intracranial vessel occlusion arising after radiotherapy for craniopharingioma. A case report and review of the literature  

Energy Technology Data Exchange (ETDEWEB)

We report a patient who developed occlusion of the intracranial major arteries induced by radiation therapy for craniopharyngioma. The patient, a 9-year-old boy, presented with deterioration of vision, nausea and vomiting. He underwent a right ventriculo-peritoneal shunt operation, and the tumor was partially removed. Postoperatively, he received focal radiation therapy with total of 60 Gy. Preoperative cerebral angiography, cerebral vessels had no sigh of occlusive lesion or stenosis. One year after irradiation, he started to have repeated cerebral ischemic attacks. But no regrowth of the tumor was detected on CT scans. Two years and 8 months after irradiation, he suddenly had right hemiparesis. Cerebral angiography revealed severe stenosis of the right anterior cerebral artery (precommunicating segment), middle cerebral artery (horizontal portion) and terminal portion of the right carotid artery. Left carotid angiography ...

1994-10-01

336

Large intracranial vessel occlusion arising after radiotherapy for craniopharingioma. A case report and review of the literature  

International Nuclear Information System (INIS)

We report a patient who developed occlusion of the intracranial major arteries induced by radiation therapy for craniopharyngioma. The patient, a 9-year-old boy, presented with deterioration of vision, nausea and vomiting. He underwent a right ventriculo-peritoneal shunt operation, and the tumor was partially removed. Postoperatively, he received focal radiation therapy with total of 60 Gy. Preoperative cerebral angiography, cerebral vessels had no sigh of occlusive lesion or stenosis. One year after irradiation, he started to have repeated cerebral ischemic attacks. But no regrowth of the tumor was detected on CT scans. Two years and 8 months after irradiation, he suddenly had right hemiparesis. Cerebral angiography revealed severe stenosis of the right anterior cerebral artery (precommunicating segment), middle cerebral artery (horizontal portion) and terminal portion of the right carotid artery. Left carotid angiography ...

1994-01-01

337

Ewing's sarcoma. Radiographic pattern of healing and bony complications in patients with long-term survival  

International Nuclear Information System (INIS)

The radiographic appearance of Ewing's sarcoma was studied retrospectively in 22 patients who survived 5 years or longer after diagnosis and treatment. Expected changes from treatment, including regression of the extraosseous soft tissue mass, periostitis, and reconstitution of the cortex, occurred in all patients. Local recurrence occurred in one patient 10 years after complete remission whereas secondary osteosarcoma occurred more than 5 years after complete remission in two other cases. Both recurrent and secondary tumors presented as new lytic foci at the site of the original primary lesion. Lytic changes from radiation (radiation osteitis) may develop more than 2 years after treatment and in this sample; such findings were widely distributed in the radiation port. The authors conclude that bone remodeling and postradiation changes occur slowly over 2 years after treatment, and that any localized lysis at the primary ...

338

Development of a phoswich detector to detect neutrons in the charged-particle mixed field  

Energy Technology Data Exchange (ETDEWEB)

Manned-space missions bring an exposure due to corpuscular radiations of which nature is quite different from what we encounter in the ground environment. In the space environment, many secondaries are produced through interactions of cosmic ray primaries with the spacecraft wall and other surrounding materials. Among this large variety of radiation components in the space, the contribution of neutrons to the radiation exposure of astronauts has remained to be studied. Up to today, efforts to measure neutron dose equivalent have been made using passive detector systems. Considering uncertainties involved in current measurements and estimations of high energy neutrons, and their increasing importance for future manned missions, it is necessary to measure neutron spectrum in the spacecraft under realistic conditions. The neutron spectra have never been measured on board a spacecraft, because the neutron measurement requires ...

1997-07-01

339

Safe detection of Co-60. New perspectives in contamination and clearance measurements  

International Nuclear Information System (INIS)

Consistent application of a newly developed coincidence technique to determine activation products in the operation and demolition of nuclear facilities results in very new perspectives in contamination monitoring and clearance measurement of plant components. In particular, it is possible to avoid the critical spread of point-source Co-60 contamination, the so-called hot particles. The CCM (Cobalt Coincidence Measurement) technique includes the coincident detection of prompt-prompt gamma cascades with "6"0Co and other activation products ("1"1"0"mAg, "1"2"4Sb, "2"2Na) with low mass-specific limits for unrestricted clearance. Special features of the technique are the short measurement times, excellent signal-to-noise ratio, and focusing in space achieved. Compared to conventional integral gamma-measurements, the signal-to-background ratio can be improved by 1-2 orders of magnitude. The method can be ...

340

Challenges in environmental radiological surveillance around nuclear facilities  

International Nuclear Information System (INIS)

To accomplish the environmental radiological surveillance need of India's ambitious nuclear power programme, Health Physics Division is infusing new technologies and improved analytical techniques for day to day measurements of various radionuclides in different environmental matrices. It is essential to have techniques for measuring the concentration of radionuclides just above the background level since the discharges from the nuclear facilities are very low i.e. in the range of 5-10% of the prescribed discharge limits by the regulatory bodies. In view of developing ultra-sensitive techniques, the aim of ongoing programmes of the division is to meet the challenges of measuring ultra trace level of radioactivity by adopting state of art new instrumentation and improved sample processing techniques. This will allow us to measure the lowest level of radioactivity (3H, 90Sr, 137Cs, 239+240Pu, etc.) in the ...

2007-06-05

341

Unilateral NMR, 13C CPMAS NMR spectroscopy and micro-analytical techniques for studying the materials and state of conservation of an ancient Egyptian wooden sarcophagus  

British Library Electronic Table of Contents (United Kingdom)

A multi-technique approach was employed to study a decorated Egyptian wooden sarcophagus (XXV?XXVI dynasty, Third Intermediate Period), belonging to the Museo del Vicino Oriente of the Sapienza University of Rome. Portable non-invasive unilateral NMR was applied to evaluate the conservation state of the sarcophagus. Moreover, using unilateral NMR, a non-invasive analytical protocol was established to detect the presence of organic substances on the surface and/or embedded in the wooden matrix. This protocol allowed for an educated sampling campaign aimed at further investigating the state of degradation of the wood and the presence of organic substances by 13C cross polarization magic angle spinning (CPMAS) NMR spectroscopy. The composition of the painted layer was analysed by optical micr...

2011-01-01

342

Multi-Mode Lamb Wave Arrival Time Extraction for Improved Tomographic Reconstruction  

International Nuclear Information System (INIS)

An ultrasonic signal processing technique is applied to multi-mode arrival time estimation from Lamb waveforms. The basic tool is a simplified time-scale projection called a dynamic wavelet fingerprint (DWFP) which enables direct observation of the variation of features of interest in non-stationary ultrasonic signals. The DWFP technique was used to automatically detect and evaluate each candidate through-transmitted Lamb mode. The area of the dynamic wavelet fingerprint was then used as a feature to distinguish false modes caused by noise and other interference from the true modes of interest. The set of estimated arrival times were then used as inputs for tomographic reconstruction. The Lamb wave tomography images generated with these estimated arrival times were able to indicate different defects in aluminum plates.

2005-04-09

343

Light from polymers - prediction of service life  

Energy Technology Data Exchange (ETDEWEB)

Stress chemiluminescence (SCL) is a novel technique for monitoring aging reactions of polymeric materials under stress. A special apparatus for detecting the chemiluminescence of solid polymers has been designed and built. There is a correlation between an enhanced chemiluminescence signal at low levels of applied stress and subsequent premature mechanical failure of samples of tetraglycidyl-4,4'-methylenedianiline (TGMDA) cured with 4,4'-diaminodiphenyl sulfone (DDS) the most commonly used epoxy in high performance fiber composites. Chemiluminescence data from silicone cushions is used to validate accelerated aging tests and preliminary results from Kevlar fibers are reported. The technique will be extended to other polymeric materials including fiber composites. 22 references, 7 figures, 1 table.

1984-01-01

344

Gear crack level identification based on weighted K nearest neighbor classification algorithm  

British Library Electronic Table of Contents (United Kingdom)

A crack fault is one of the damage modes most frequently occurring in gears. Identifying different crack levels, especially for early cracks is a challenge in gear fault diagnosis. This paper aims to propose a method to classify the different levels of gear cracks automatically and reliably. In this method, feature parameters in time domain, specially designed for gear damage detection and in frequency domain are extracted to characterize the gear conditions. A two-stage feature selection and weighting technique (TFSWT) via Euclidean distance evaluation technique (EDET) is presented and adopted to select sensitive features and remove fault-unrelated features. A weighted K nearest neighbor (WKNN) classification algorithm is utilized to identify the gear crack levels. The gear crack experime...

2009-01-01

345

Detection of glycoproteins in the Acanthamoeba plasma membrane  

International Nuclear Information System (INIS)

In the present study the authors have shown that glycoproteins are present in the plasma membrane of Acanthamoeba castellanii by utilizing different radioactive labeling techniques. Plasma membrane proteins in the amoeba were iodinated by "1"2"5I-lactoperoxidase labeling and the solubilized radiolabeled glycoproteins were separated by lectin-Sepharose affinity chromatography followed by polyacrylamide gel electrophoresis. The periodate/NaB"3H_4 and galactose oxidase/NaB"3H_4 labeling techniques were used for labeling of surface carbohydrates in the amoeba. Several surface-labeled glycoproteins were observed in addition to a diffusely labeled region with M_r of 55,000-75,000 seen on electrophoresis, which could represent glycolipids. The presence of glycoproteins in the plasma membrane of Acanthamoeba castellanii was confirmed by metabolic labeling with ["3"5S]methionine followed by lectin-Sepharose affinity chromatography and polyacrylamide gel ...

346

Comparison of effectiveness of three radon detectors (LR115, CR39 and silicon diode pin) placed in a cylindrical device -theory and experimental techniques  

Energy Technology Data Exchange (ETDEWEB)

Researchers at the Laboratory of Nuclear Microanalysis in Besancon (France) are developing and improving radon measurements in order to detect and analyse, more precisely radon emanation anomalies in both fields of Earth Sciences and Radioprotection. In order to characterize radon emanation, two complementary techniques are developed; continuous measurement through a portable proportional counter and passive measurements by nuclear track detectors for both fieldwork and laboratory analysis. A mathematical model is being devised to interpret the nuclear track detector response. This model is performed according to the device characteristics: type of detectors, shape and size of cells and whether a membrane is used or not. In addition to the theoritical study, experimental radon concentration measurements will be reported. (author).

1993-12-31

347

Comparison of effectiveness of three radon detectors (LR115, CR39 and silicon diode pin) placed in a cylindrical device -theory and experimental techniques  

International Nuclear Information System (INIS)

Researchers at the Laboratory of Nuclear Microanalysis in Besancon (France) are developing and improving radon measurements in order to detect and analyse, more precisely radon emanation anomalies in both fields of Earth Sciences and Radioprotection. In order to characterize radon emanation, two complementary techniques are developed; continuous measurement through a portable proportional counter and passive measurements by nuclear track detectors for both fieldwork and laboratory analysis. A mathematical model is being devised to interpret the nuclear track detector response. This model is performed according to the device characteristics: type of detectors, shape and size of cells and whether a membrane is used or not. In addition to the theoritical study, experimental radon concentration measurements will be reported. (author).

348

An analytical framework for data stream mining techniques based on challenges and requirements  

CERN Document Server

A growing number of applications that generate massive streams of data need intelligent data processing and online analysis. Real-time surveillance systems, telecommunication systems, sensor networks and other dynamic environments are such examples. The imminent need for turning such data into useful information and knowledge augments the development of systems, algorithms and frameworks that address streaming challenges. The storage, querying and mining of such data sets are highly computationally challenging tasks. Mining data streams is concerned with extracting knowledge structures represented in models and patterns in non stopping streams of information. Generally, two main challenges are designing fast mining methods for data streams and need to promptly detect changing concepts and data distribution because of highly dynamic nature of data streams. The goal of this article is to analyze and classify the application of diverse data mining ...

2011-01-01

349

Amino acid substitution: its use in detection and analysis of genetic variants  

International Nuclear Information System (INIS)

Techniques of chemical analysis, amino acid sequencing and autoradiography are being used to study the frequency of incorporation of normally noncoded amino acids into hemoglobins and seminal fluid proteins. We are studying, by the sequencing of radiolabeled proteins followed by the recovery of ["3H] isoleucine phenylthiohydantoin by high-performance liquid chromatography, the frequency at which normally noncoded isoleucine is incorporated into hemoglobin because of base-substitution mutations versus translational errors. Irradiation increases the isoleucine content of human hemoglobin and the frequency of substitution of isoleucine for specific amino acids in rabbit hemoglobin. Studies to date indicate that these techniques have been developed sufficiently for initial analysis of the potential of drugs and environmental pollutants to induce base-substitution mutations in mammalian somatic cells.

350

Current status and future plan of JMTR Hot Laboratory  

Energy Technology Data Exchange (ETDEWEB)

The newly developed techniques by the Hot Laboratory (JMTR HL) have provided for us the key information on behavior of specimens due to mechanical / physical / chemical / synergistic effects of radiation, stress and water for fission and fusion reactor environment. These techniques are focused on several topics as follows; (1) miniaturized specimen test for the development of fusion reactor materials, (2) slow strain rate tensile testing (SSRT) and crack propagation measuring tests for the study of Irradiation Assisted Stress Corrosion Cracking (IASCC) of core internals of LWR, (3) handling technique on specimens including tritium for the research and development of tritium breeders and neutron multiplier as fusion blanket materials, (4) joining method using the Tungsten Inert Gas (TIG) welding technique for re-assembling of capsule and re-fabrication of specimen and (5) ...

1999-08-01

351

Some comments on BEIR III  

International Nuclear Information System (INIS)

... organizations irradiation radiation doses radiation effects RADIATIONS.

1982-01-01

352

Radiation technology of wood-plastic composite materials  

International Nuclear Information System (INIS)

... radiation effects RADIATIONS. WOOD-PLASTIC COMPOSITES.

1981-10-02

353
354

Rapid Responding Palladium-Silver Surface Modified Microsensor for Hydrogen  

Science.gov (United States)

Most palladium thin film based hydrogen gas sensors have response and recovery times that are too long to make them useful in vehicular and stationary gas leak detection applications. In contrast, a palladium-silver thin film based microcantilever (MC) hydrogen gas microsensor is reported herein with near ideal response characteristics for use in these hydrogen economy related applications. Specifically, 3-10 second response and recovery times have been measured for these sensors in contrast to previous sensor response measurements of several to tens of minutes using Pd thin film and MC based sensing techniques. The much reduced response times observed in the present study are attributed to a wet chemical Pd-Ag thin film deposition technique and a gas conditioning protocol that produces a highly nanostructured, porous film that rapidly adsorbs and desorbs H2, allowing rapid equilibration with the H2 concentration in the ...

2010-01-01

355

Field experience with eddy current X-probes in CANDU steam generators and heat exchangers  

Energy Technology Data Exchange (ETDEWEB)

CANDU steam generators and heat exchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if not all of the functions of the other tube-testing eddy current ...

2006-07-01

356

Field experience with eddy current X-probes in CANDU steam generators and heat exchangers  

International Nuclear Information System (INIS)

CANDU steam generators and heat exchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if not all of the functions of the other tube-testing eddy current ...

2005-11-20

357

Evaluation of paramagnetic species in coals with iodine doping technique; Yoso tenkaho wo mochiita sekitanchu no jojiseishu no hyoka  

Energy Technology Data Exchange (ETDEWEB)

Electron paramagnetic resonance (EPR) of coals was considered by using iodine doping technique. Sub-bituminous coal (WA) and bituminous coal (UF) were used to observe EPR spectra using microwaves. With the UF coal, strength of the narrow component of the spectra was found constant regardless of amount of the doped iodine, wherein radicals without interaction with iodine were detected. Strength of the broad component increased with the iodine doping amount, where in deviation of {pi} electrons was detected, which have been generated as a result of interaction between aromatic rings and iodine in the coals. Spin concentration of the WA coal with low coalification degree is constant regardless of the iodine doping amount, and the interaction of the iodine with the aromatic rings was found small. The higher the coalification degree, the more the aromatic ring structure grows, and electron donor capability for the iodine ...

1996-10-28

358

Detection of Second-Layer Corrosion in Aging Aircraft  

International Nuclear Information System (INIS)

The Compton backscatter technique has been applied to lap-joint in aircraft structure in order to determine mass loss due to exfoliative corrosion of the aluminum alloy sheet skin. The mass loss of each layer has been estimated from Compton backscatter A-scan including the aluminum sheet, the corrosion layer, and the sealant. A Compton backscattering imaging system has been also developed to obtain a cross-sectional profile of corroded lap-splices of aging aircraft using a specially designed slit-type camera. The camera is to focus on a small scattering volume inside the material from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the layered structure is scanned by moving the scattering volume through the thickness direction of the specimen. The theoretical model of the Compton scattering based on Boltzmann transport theory is presented for quantitative ...

2009-12-01

359

Ultrafast resonance energy transfer in bio-molecular systems  

British Library Electronic Table of Contents (United Kingdom)

In this article, we present our consistent efforts to explore the dynamical pathways of the migration of electronic radiation by using ultrafast (picosecond/femtosecond time scales) F?rster resonance energy transfer (FRET) technique. The ultrafast non-radiative energy migration from an intrinsic donor fluorophore (Tryptophan, Trp214) present in domain IIA of a transporter protein human serum albumin (HSA) to various non-covalently/covalently attached organic/inorganic chromophores including photoporphyrin IX (PPIX), polyoxovanadate [V15As6O42(H2O)]-6 clusters (denoted as V15) and CdS quantum dots (QDs) has been explored. We have also used other covalently/non-covalently attached extrinsic fluorogenic donors (NPA, ANS) in order to exploit the dynamics of resonance energy migration of an enz...

2010-01-01

360

The effects of radiation on unsteady mhd convective heat transfer past a semi-infinite vertical porous moving surface with variable suction  

Scientific Electronic Library Online (English)

Abstract in english Numerical solutions for the effects of radiation on a MHD convective heat transfer past a semi-infinite porous plate with a magnetic field are obtained. It is assumed that the porous plate moves with a constant velocity in the direction of fluid flow, and the free stream velocity follows the exponentially increasing small perturbation law. The magnetic field acts perpendicular to the porous surface which absorbs the fluid with a suction velocity varying with time. The gov (more) erning equations for the flow are transformed into a system of nonlinear ordinary differential equations by perturbation technique and then are solved numerically by using the shooting method. The effects of the various parameters on the velocity, temperature profiles as well as the surface skin-friction and surface heat transfer are illustrated graphically.

2008-12-01

361

Optical properties and up-conversion of Pr"3"+ doped CdS nanoparticles in sol-gel glasses  

International Nuclear Information System (INIS)

Silica glasses containing Pr"3"+ with and without CdS nanoparticles were prepared by sol-gel technique. The influence of CdS nanoparticles on Pr"3"+ doped glass was studied by absorption, photoluminescence and up-conversion. From the measured intensities of various absorption bands of these glasses, the Judd-Ofelt parameters ?_2, ?_4 and ?_6 have been evaluated. The radiative transition probability (A), radiative lifetime (?_R), branching ratio (?_R) and integrated emission cross-section (?_P) were calculated from excited states of "3P_1 and "3P_0 levels. The up-conversion emissions were found in the green, orange and red regions under 800 nm excitation with peaks 559, 612 and 688 nm respectively. On excitation with 370 nm also leads to similar green, orange and red regions.

2010-10-01

362

Intraoperative radiation therapy at the National Cancer Institute: technical innovations and dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The technical complexity of intraoperative radiotherapy (IORT) requires modification of the standard physical and dosimetric methods used in external electron beam therapy. At the National Cancer Institute, a number of technical innovations have been integrated into ongoing clinical studies of IORT. These include: (1) an electron beam applicator system that is significantly different from other IORT systems and includes customized squircle applicators; (2) peripheral dose shields; (3) a modified surgical table replacing the standard radiation treatment couch; and (4) routine use of multiple IORT fields that necessitates field matching. The IORT applicator system and related devices and techniques are dosimetrically characterized in detail both for use in the IORT program and in order to illustrate many useful facets of electron dosimetry.

1985-07-01

363

Effect of gamma rays on grafting parameters and liquid retention property of cassava starch-g-PAN  

International Nuclear Information System (INIS)

Radiation modification on liquid retention properties of native cassava starch, gelatinized at 85"0C, by graft copolymerization with acrylonitrile was carried out by mutual irradiation to #gamma#-rays. A thin aluminium foil was used to cover the inner wall of the reaction vessel so that the extent of homo polymer could be reduced to be less than 1.6% with a distilled water retention value of 665 g/g of the dry weight of the saponified grafted product. Confirmations of graft copolymerization and saponification reactions were made by the infrared spectrophotometric technique. The combined effect of radiation parameters in terms of an irradiation time and a dose rate to the same total dose on the extent of grafting reaction expressed in terms of grafting parameters which directly influenced liquid retention values was evaluated in conjunction with statistical analysis.

1992-10-20

364

Dosimetric evaluation of multi-pattern spatially fractionated radiation therapy using a multi-leaf collimator and collapsed cone convolution superposition dose calculation algorithm  

British Library Electronic Table of Contents (United Kingdom)

Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle3 treatment planning system, and the dose was calculated in a water phantom. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as w...

2009-01-01

365

Application of microvascular free osteocutaneous flaps in the management of post-radiation recurrent oral cancer  

Energy Technology Data Exchange (ETDEWEB)

Fifty-nine patients underwent free flap osteocutaneous reconstruction that consisted of flaps of the dorsum of the foot in 26 patients and iliac crest flaps in 33 with a success rate of 92 percent and a mortality rate of 1.6 percent. These flaps, which require the expertise of microvascular surgeons, are time-consuming and complicate operating room and time management, but they represent a remarkable advance in reconstruction that can facilitate cosmetic and functional recovery of the patient. In particular, they promote healing in radiation-recurrent oral cancer and represent a definitive form of management for established radionecrosis of the mandible. The large volume of tissue available with iliac crest osteocutaneous grafts permits the management of patients with extensive cancer involving the skin, mucosa, and bone, but cancer control may still be disappointing and there is a need for improved adjuvant chemotherapy protocols. This ...

1985-10-01

366

ASFIT-VARI: A practical gamma-ray transport code for MS-DOS computers  

Energy Technology Data Exchange (ETDEWEB)

The ASFIT (Anisotropic Source-Flux Iteration Technique) code was first developed in India about 1970 to solve the radiation transport equation represented in the form of coupled integral equations separating the spatial and energy-angular transmissions. The ASFIT code uses a nodal structure in the wavelength [lambda] domain in Compton units (CU) rather than in the energy domain. The ASFIT-VARI code is the latest version available from the Radiation Shielding Information Center. It incorporates variable dimensioning and has been adapted for use on MS-DOS personal computers using the Ryan-McFarland or Microsoft Version 5.0 FORTRAN compilers. While earlier versions used point cross sections (well suited for gamma-ray transport), the present version also allows multigroup cross sections for neutron and coupled neutron-gamma-ray transport.

1990-01-01

367

A semi-analytic approach to angular momentum transport in stellar radiative interiors  

British Library Electronic Table of Contents (United Kingdom)

ABSTRACT We address the problem of angular momentum transport in stellar radiative interiors with a novel semi-analytic spectral technique, using an eigenfunction series expansion, that can be used to derive benchmark solutions in hydromagnetic regimes with very high Reynolds number (107-108). The error arising from the truncation of the series is evaluated analytically. The main simplifying assumptions are the neglect of meridional circulation and of non-axisymmetric magnetic fields. The advantages of our approach are shown by applying it to a spin-down model for a Formula Not Shown main-sequence star. The evolution of the coupling between core and envelope is investigated for different values of the viscosity and different geometries and values of the poloidal field. We confirm that a vi...

2010-01-01

368

Wet limestone FGD solids analysis by thermogravimetry  

Energy Technology Data Exchange (ETDEWEB)

Wet limestone scrubbing is once again becoming a popular technology for removal of sulfur dioxide (SO{sub 2}) from power plant emissions. Critical to the operation of wet limestone flue gas desulfurization (FGD) systems is accurate chemical analysis of scrubber solids. The analytical technique of thermogravimetry is ideal for this application, as the instrument can give precise readings of the principal scrubber solids components, calcium sulfite/sulfate hemihydrate, calcium sulfate dihydrate (gypsum), and unused calcium carbonate. The data provides plant chemists, engineers, and operators with information needed to fine-tune scrubber operation and detect process upsets. (orig.)

2004-07-01

369

The use of x-ray fluorescence in the detection of inorganic elements in medicines drugs  

International Nuclear Information System (INIS)

Based on the instrumental wavelength dispersive X-ray fluorescence technique of analysis (W D-X R F), the inorganic elements in four samples of commercial medicines drugs were analyzed. The samples were used without any chemical separation of the elements or chemical pre-treatment. Eleven elements could be identified, namely Si, P, S, Cl, K, Ca, Ti, Mn, Fe, Cu and Zn. However, Si, Ti and Mn have not been mentioned in the printed instructions for the use of the medicines drugs by the producers. (author)

370

Semantic network array processor and its applications to image understanding  

Energy Technology Data Exchange (ETDEWEB)

The problems in computer vision range from edge detection and segmentation at the lowest level to the problem of cognition at the highest level. This correspondence describes the organization and operation of a semantic network array processor (SNAP) as applicable to high level computer vision problems. The architecture consists of an array of identical cells each containing a content addressable memory, microprogram control, and a communication unit. The applications discussed in this paper are the two general techniques, discrete relaxation and dynamic programming. While the discrete relaxation is discussed with reference to scene labeling and edge interpretation, the dynamic programming is tuned for stereo.

1987-01-01

371

Review of recent proteomic applications in aquatic toxicology  

British Library Electronic Table of Contents (United Kingdom)

Abstract Over the last decade, the environmental sciences have witnessed an incredible movement towards the utilization of high-throughput molecular tools that are capable of detecting simultaneous changes of hundreds, and even thousands, of molecules and molecular components after exposure of organisms to different environmental stressors. These techniques have received a great deal of attention because they not only offer the potential to unravel novel mechanisms of physiological and toxic action but are also amenable to the discovery of biomarkers of exposure and effects. In this article, we review the state of knowledge of one of these tools in ecotoxicological research: proteomics. We summarize the state of proteomics research in fish, and follow with studies conducted with aquatic in...

2011-01-01

372

Primary standardization of {sup 242} Am radioactive sources  

Energy Technology Data Exchange (ETDEWEB)

The procedure followed by the Laboratorio de Metrologia Nuclear in Sao Paulo, Brazil, for the standardization of {sup 242g} Am is described. The calibration system was composed of a 4 {pi} gas-flow proportional counter coupled to a pair of NaI(Tl) crystals operating in coincidence. The samples were produced by irradiating dried aliquots of {sup 241} Am with thermal and epithermal neutrons at the IEA-R1 research reactor. The efficiency tracer technique has been applied using {sup 60} Co as tracer. The beta detection efficiency was changed by external absorbers and extrapolated to unity by linear least square fitting applying covariance methodology. (author)

2001-07-01

373

Presentations from 2nd Cryogenic Operations Workshop (CRYO 2006) , May 9-11, 2006, Menlo Park, California  

Science.gov (United States)

This workshop covered the latest practical engineering and operational management applications and techniques that have been found to enhance operational costs, reliability, and flexibility, with topics such as establishing the optimal refrigeration design cycle and operating design points; utility management; manpower scheduling; plant control philosophy and automation; short and long term maintenance scheduling; refrigerant loss detection and control; system contamination; component reliability; and equipment technical performance issues.

2006-11-10

374

Machine Learning Techniques for Biometrics  

Science.gov (United States)

This chapter reports recent advances in the statistical learning literature that may be of interest for biometrics. In particular we discuss two different algorithmic settings, binary classification and multi-task learning, and analyze the two closely related problems of feature selection and feature learning. In the binary case the theoretical and algorithmic advances to feature selection are applied to solve face detection and face authentication problems. In the multi-task case we show how the data structure described by a group of features common to the various tasks can be effectively learned, and then we discuss how this approach could be used to address face recognition.

2009-01-01

375

Intermediate mass Higgs study at {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We present the efficient technique to extract the signal of the intermediate mass Higgs boson from the backgrounds at future {gamma}{gamma} colliders. For a clear Higgs detection, it is important to fit the original electron accelerator energy depending on the Higgs mass, to set the polarization of the photon beams and to apply the efficient b quark tagging method. we demonstrate the extraction of information of Higgs parameters and the new physics from the observable physical quantities. It is clearly shown that a future {gamma}{gamma} collider will have a rich potential for study on the new physics, as well as the Higgs physics. (author).

1995-05-01

376

Intermediate mass Higgs study at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We present the efficient technique to extract the signal of the intermediate mass Higgs boson from the backgrounds at future #gamma##gamma# colliders. For a clear Higgs detection, it is important to fit the original electron accelerator energy depending on the Higgs mass, to set the polarization of the photon beams and to apply the efficient b quark tagging method. we demonstrate the extraction of information of Higgs parameters and the new physics from the observable physical quantities. It is clearly shown that a future #gamma##gamma# collider will have a rich potential for study on the new physics, as well as the Higgs physics. (author).

1995-05-01

377

Improved beam confinement in the modified betatron with strong focusing  

International Nuclear Information System (INIS)

The lifetime of the circulating electron beam in the Naval Research Laboratory modified betatron has been increased by more than 2 orders of magnitude with the addition of strong focusing windings to the device. The injected beam consistently spirals from the injector to the minor axis and is trapped. The #approx#0.5-kA trapped electron ring has been accelerated above 10 MeV from the injection energy of 0.5 to 0.6 MeV. The beam acceleration has been confirmed not only by the x-ray attenuation technique but also with the detection of photoneutrons.

378

Confocal Imaging of Biological Tissues Using Second Harmonic Generation  

Energy Technology Data Exchange (ETDEWEB)

A confocal microscopy imaging system was devised to selectively detect Second harmonic signals generated by biological tissues. Several types of biological tissues were examined using this imaging system, including human teeth, bovine blood vessels, and chicken skin. All these tissues generated strong second harmonic signals. There is considerable evidence that the source of these signals in tissue is collagen. Collagen, the predominant component of most tissues, is known to have second order nonlinear susceptibility. This technique may have diagnostic usefulness in pathophysiological conditions characterized by changes in collagen structure including malignant transformation of nevi, progression of diabetic complications, and abnormalities in wound healing.

2000-03-06

379

Application of the digital waveform analysis to Bragg curve spectrometer  

International Nuclear Information System (INIS)

Energy and angular double-differential cross-section (DDX) data of fragment production reactions by neutrons or protons are very scarce due to experimental difficulties of fragment detection. We adopted a Bragg curve spectrometer (BCS), which is a gridded-ionization chamber that can identify fragments on the basis of the Bragg peak value. We have been developing the BCS for neutron and proton-induced reactions applying the digital waveform analysis technique to obtain better ability of particle discrimination than the analog electronic circuit. (T. Tanaka)

2004-11-01

380

Application of proportional counters in Polish medicine and agriculture  

Energy Technology Data Exchange (ETDEWEB)

In the laboratory of Elementary Particle Physics and Detectors at the Faculty of Physics and Nuclear Techniques of the University of Mining and Metallurgy, research works on the development of proportional counters for the detection of X- and soft {gamma}-rays and {alpha}, {beta} particles have been carried out As a result of optimization of counters characteristic parameters such as: energy resolution, life time, count rate effect and temperature effect the operating stability has been reached and the elaborated detectors have been applied not only in research laboratories, but also in Polish industry, medicine and agriculture. Examples of above mentioned applications have been presented in the paper. (author). 7 refs, 7 figs, 1 tab.

1996-12-31

381

An optical fiber methane sensing system employing a two-step reference measuring method  

British Library Electronic Table of Contents (United Kingdom)

An optical fiber methane sensing system utilizing a super-luminescent diode (SLD) in the 1.33-mm band and a fiber Fabry-Perot tunable filter (FFP-TF) is developed. A two-step reference measuring method, which is based on differential absorption technique, is employed; a reference channel is introduced to eliminate the fluctuation of the illuminant spectrum, and the reference wavelength acquired by tuning the FFP-TF is introduced to eliminate the environmental influence. The two-step reference measuring method has improved the reliability and stability of the system. A minimum detectable methane concentration of 0.3% has been experimentally achieved.

2008-01-01

382

A Two-Step Etching Method to Fabricate Nanopores in Silicon  

CERN Document Server

A cost effectively method to fabricate nanopores in silicon by only using the conventional wet-etching technique is developed in this research. The main concept of the proposed method is a two-step etching process, including a premier double-sided wet etching and a succeeding track-etching. A special fixture is designed to hold the pre-etched silicon wafer inside it such that the track-etching can be effectively carried out. An electrochemical system is employed to detect and record the ion diffusion current once the pre-etched cavities are etched into a through nanopore. Experimental results indicate that the proposed method can cost effectively fabricate nanopores in silicon.

2008-01-01

383

Safety assessment and life time management of nuclear power plants: from reasonable design to reliable structural health monitoring  

International Nuclear Information System (INIS)

Nowadays the safety of Nuclear Power Plants is becoming more and more significant. Therefore consideration of severe accidents shall be included in both design and operating process of Nuclear Power Plants. In particular ground motion forms one of the important natural hazards. For structural analysis both linear-elastic and non-linear methods are specified by the engineering codes for earthquake resistance design. However, time history analysis is required for investigation of non-linear structural behaviour. Moreover, non-linearities are often caused by the presence of damage. This can be detected by means of structural health monitoring and subsequently system identification. In this paper the advantages of both dynamic time history analysis and damage detection by means of wavelet analysis are discussed. First, the non-linear behaviour of a frame structure due to an artificial earthquake motion is analyzed. A comparison to non-time history ...

2005-06-15

384

Experience with abdominal gamma imaging in patients with bleeding of the lower digestive tube  

International Nuclear Information System (INIS)

This study concerns our experiences with abdominal gamma imaging using Tc-99m colloid and with abdominal angiography using Tc-99m-pyrophosphate labelled erythrocytes ''in vivo'' based on the modified technique described by Callahan. The dynamic or perfusion phase was first performed, then the static phase during which for the first two hours scans were taken every 15 minutes and thereafter every 4-6 hours. The routine image corresponds to the first, although it was necessary at times to take oblique projections. The study was felt to be accomplished after 48 hours upon observing no extravasation of radioactive material in the abdominal region, or upon detecting a bleeding site. The investigation was performed on 11 patients, 8 having positive scans of abdominal extravasation, later confirmed in 6 by endoscopy and by surgery. In 2, the presence of salmonelosis was shown by laboratory analysis. Endoscopy and angiography XR are both invasor ...

1985-04-25

385

Double-Edge Molecular Measurement of Lidar Wind Profiles in the VALID Campaign  

Science.gov (United States)

We have developed a transportable container based direct detection Doppler lidar based on the double-edge molecular technique. The pulsed solid state system was built at the University of Geneva. It was used to make range resolved measurements of the atmospheric wind field as part of the VALID campaign at the Observatoire de Haute Provence in Provence, France in July 1999. Comparison of our lidar wind measurements, which were analyzed without knowledge of the results of rawinsonde measurements made under the supervision of ESA, show good agreement with these rawinsondes. These are the first Doppler lidar field measurements made with an eyesafe direct detection molecular-based system at 355 nm and serve as a demonstrator for future spaceborne direct detection wind systems such as the Atmospheric Dynamics mission. Winds are an important contributor to sea surface temperature measurements made with the ...

2000-01-01

386

Computed tomography of the thorax: a status report  

Energy Technology Data Exchange (ETDEWEB)

Computed tomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computed tomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. Future applications of CT include the ...

1981-11-01

387

Computed tomography of the thorax: a status report  

International Nuclear Information System (INIS)

Computed tomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computed tomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. Future applications of CT include the ...

388

Effect of inhaled beclomethasone dipropionate on isocapnic hyperventilation with cold air in asthmatics, measured with forced oscillation technique.  

Science.gov (United States)

Isocapnic hyperventilation with cold air (IHCA) is a reliable technique for assessing indirect bronchial hyperresponsiveness in patients with asthma. Impedance measurement of the respiratory system by the forced pseudorandom noise oscillation technique is a sensitive technique to assess changes in bronchial tone after IHCA. The aim of this study was to evaluate the effect of 6 weeks of treatment with beclomethasone dipropionate, 1,000 microg x day-1, on IHCA in asthmatic patients, measured with both forced oscillation technique and flow-volume recordings. Forty patients with mild asthma were included in this double-blind, placebo-controlled parallel-group study. Stratification on the basis of sex was performed to overcome differences in airway diameter. At entry and every 2 weeks during the treatment period, IHCA was performed and patient diaries were evaluated. Characteristic changes in forced ...

1997-03-01

389

The influence of different SPECT reconstruction algorithms on cardiac ischemia with the use artificial neural networks  

International Nuclear Information System (INIS)

The aim of the study was the attempt to evaluate the influence of two different methods of cardiac perfusion SPECT reconstruction (FBP and ITW) on clinical efficacy in diagnosing the coronary artery disease as well as the cardiac ischemia detection in three areas of heart vascularized by main coronary arteries: LAD, LCX and RCA with the use of artificial neural networks (ANN). The study was performed retrospectively with the use of the diagnostic image records as well as clinical dataset of 43 patients. Myocardial perfusion stress/rest SPECT study and X-ray coronarography data were evaluated for each patient. The results of coronary angiography were considered the reference method. The cardiac SPECT data were reconstructed using the two different methods: filtered backprojection (FBP) and iterative Wallis method (ITW). The local perfusion deficits denominated in stress and rest study in three main vessel cardiac segments were the main input values for the ANN. The ...

390

Fault detection and diagnosis of a gearbox in marine propulsion systems using bispectrum analysis and artificial neural networks  

Science.gov (United States)

A marine propulsion system is a very complicated system composed of many mechanical components. As a result, the vibration signal of a gearbox in the system is strongly coupled with the vibration signatures of other components including a diesel engine and main shaft. It is therefore imperative to assess the coupling effect on diagnostic reliability in the process of gear fault diagnosis. For this reason, a fault detection and diagnosis method based on bispectrum analysis and artificial neural networks (ANNs) was proposed for the gearbox with consideration given to the impact of the other components in marine propulsion systems. To monitor the gear conditions, the bispectrum analysis was first employed to detect gear faults. The amplitude-frequency plots containing gear characteristic signals were then attained based on the bispectrum technique, which could be regarded as an index actualizing forepart gear faults diagnosis. ...

2011-03-01

391

Comparison of high resolution whole-body MRI using parallel imaging and PET-CT. First experiences with a 32-channel MRI system  

International Nuclear Information System (INIS)

To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI scanner (Magnetom Avanto, Siemens Medical Solutions) with a total field of view of 205 cm and free table ...

392

Process-integrated online monitoring of safety-relevant aluminum airbag pressure vessel components for a combined defect detection and material property determination by using contactless NDT (EMUS and EC)  

Energy Technology Data Exchange (ETDEWEB)

Airbag pressure vessels for the north-American market mainly are made by forging and by the use of steel alloys. In Europe aluminum alloys are common and the manufacturing process is extrusion of circular blanks - made from cold rolled plates - in a form applying a 100 t press at room temperature. Then by heat treatment the strength/hardness of the material is properly adjusted and after that the pressure vessel parts have to be continuously inspected with an inspection and handling cycle time of 3 s. Inspection of the axis-symmetric parts is asked for surface breaking extrusion defects as well as for surface parallel delaminations in the bulk volume. Furthermore, the material strength is a quality characteristic that has to be nondestructively registered and documented. The inspection is performed by eddy current probes and an EMAT, of which the eddy current impedance measurements are used for surface breaking extrusion defect detection and sizing (single ...

1999-07-01

393

Development of an assay for a biomarker of pregnancy and early fetal loss  

Energy Technology Data Exchange (ETDEWEB)

Human chorionic gonadotropin (hCG) is a glycoprotein hormone, secreted by the syncytiotrophoblast cells of the fertilized ovum, that enters the maternal circulation at the time of endometrial implantation. It is composed of two nonidentical subunits; ..cap alpha.. and ..beta.., with molecular weights of 14 kD and 23 kD, respectively. Human chorionic gonadotropin binds to the same receptor as hLH and displays the same biological response, namely, to stimulate the declining function of the corpus luteum to produce progestins and estrogen late in the menstrual cycle. The differences in the structures of hCG and hLH have been exploited to develop antibodies that can measure hCG specifically in the presence of hLH. Two-site antibody binding assays have been developed, based on a surface immunological concept of hCG epitopes, that involve four distinct regions to which antibodies against hCG can bind simultaneously. Antibody cooperative effects, in conjunction with kinetic advantages derived ...

1987-10-01

394

The electron cyclotron absorption diagnostic for the JET pumped divertor plasma  

International Nuclear Information System (INIS)

We present the design of a diagnostic system to measure electron cyclotron absorption at the second harmonic E-mode resonance in the JET pumped divertor plasma. The diagnostic will measure transmission as a function of frequency along one or more sightlines from which the spatial profile of the n_eT_e product will be deduced. The divertor is briefly described, and the electron cyclotron resonance physics relevant to this measurement is reviewed. The problems of measuring transmission using an oversized transmission system are discussed and the chosen measurement technique, a swept frequency interferometer using a coherent radiation source, is described. A prototype of the instrument has been assembled to test the measurement technique. Some data demonstrating the instrument's characteristics are presented. The nonresonant losses, which may affect the interpretation of the measurement, are also discussed. (orig.).

1993-03-01

395

Quantitative Computed Tomography (QCT) of vertebral spongiosa. Evaluation of a possible method for managment of postmenopausal osteoporosis (PMO)  

International Nuclear Information System (INIS)

A Quantitative Computed Tomography (QCT) method, simplifying the well-known technique proposed by Genant (1982) and applied to a standard third generation whole body CT scanner is described. This technique was applied in the measurement of the trabecular bone which has high sensitivity for metabolic changes. The BMC (Bone Mineral Content) measured in different groups of subjects (healthy postmenopausal patients versus women with postmenopausal osteoporosis) showed a highly significant difference (p<0.001). The precision of repositioning (coefficient of variation 1.8% to 2.3%, obtained in healty male patients) and the good, linear relationship computed from the phantom values, minimize measurement errors. Since this method is quickly applied and involves low-dose radiation-exposure, it could be introduced in the clinical study of metabolic bone diseases.

1987-01-01

396

Practical technological benefits of SRE decommissioning  

Energy Technology Data Exchange (ETDEWEB)

The decommissioning of the Sodium Reactor Experiment is essentially complete. Contaminated materials, equipment, and soil were removed, decreasing the residual radioactivity to levels acceptable for future unrestricted use of the site. The fuel was removed and declad, tooling and techniques to support the decommissioning were developed, bulk sodium and residual sodium films were removed, coolant systems were dismantled, the reactor vessel was dissected, the interior surfaces of the facilities were decontaminated, and waste materials were packaged and shipped to burial sites. Radiation exposure to workers and the public was within the guidelines and as low as reasonably achievable. In performing the project, new decontamination techniques were tested, decontamination equipment was evaluated, and waste disposal methods were developed.

1982-01-01

397

Diffusion examined by diffraction  

Science.gov (United States)

X-ray diffraction offers a unique combination of advantages for kinetic study which include the non-destructive nature of the measurement, the use of bulk crystals, and the convenience of the experimental arrangements. These attributes and the availability of position-sensitive detectors and high-flux synchrotron radiation sources make this technique most useful for in situ, dynamical investigations. When using diffraction techniques to determine a diffusion coefficient, the principle of analysis entails a scattering theory and a kinetic model. The former allows the kinetic parameter(s) to be extracted from measured intensity, while the latter relates the kinetic parameter(s) to the diffusion coefficient(s). Three examples are demonstrated: (1) Palladium Silicide (Pd{sub 2}Si) Layer Growth on Silicon, (2) Decomposition of an Ni-12.5at%Si Superalloy, and (3) Short-range Ordering in Cu-Au Solid Solutions.

398

Radiation therapy for Ewing's sarcoma: Results from Memorial Sloan-Kettering in the modern era  

International Nuclear Information System (INIS)

Purpose: To evaluate the outcomes of patients with Ewing's sarcoma family of tumors (ESFT) treated with modern radiotherapy techniques with MRI along with optimal chemotherapy. Methods and Materials: The records of all 60 patients with ESFT who received radiation to the primary site between 1990 and 2004 were reviewed. All patients received chemotherapy, including vincristine, doxorubicin, cyclophosphamide, ifosfamide, and etoposide. Radiation was used as the sole modality for local control in 31 patients and was given either before (n = 3) or after surgical resection (n = 26) in the remainder. All patients had MRI and CT scan-based treatment planning, and 43% received intensity-modulated radiation therapy. Radiation doses ranged from 30 Gy to 60 Gy (median, 51 Gy), and 35% received hyperfractionated radiotherapy. Results: Median age was 16 years (range, 2-40 years). Because of ...

2006-02-01

399

Different techniques for measuring radon concentration in a spa environment  

International Nuclear Information System (INIS)

In the context of radiation protection for both workers and the population in general, natural sources of radiation, and in particular radon gas and its short-life decay products assume great importance. In particular, workers in thermal spas can easily be exposed to a level of radon radiation and its decay products comparable to those in uranium mines, though often these workers are unaware of the danger. The main source of radon in thermal baths is the thermal water itself, coming as it often does from deep springs, and this can produce high radon concentrations which are left in those areas in which therapy is carried out. Another factor which cannot be overlooked is the radioactive content of thermal mud, often matured for long periods by contact with thermal water. Thermal cures, though varying slightly from site to site, consist principally of mud cures, hydro-therapy and inhalation in various forms. Both health ...

2002-10-08

400

Development of a pump-probe facility combining a far-infrared source with laser-like characteristics and a VUV free electron laser  

International Nuclear Information System (INIS)

The TESLA Test Facility (TTF) at DESY is a facility producing sub-picosecond electron pulses for the generation of VUV or soft X-ray radiation in a free electron laser (FEL). The same electron pulses would also allow the direct production of high-power coherent radiation by passing the electron beam through an undulator. Intense, coherent far-infrared (FIR) undulator radiation can be produced from electron bunches at wavelengths longer than or equal to the bunch length. The source described in this paper provides, in the wavelength range 50-300 #mu#m, a train of about 1-10 ps long radiation pulses, with about 1 mJ of optical energy per pulse radiated into the central cone. The average output power can exceed 50 W. In this conceptual design, we intend to use a conventional electromagnetic undulator with a 60 cm period length and a maximum field of 1.5 T. The FIR source will use the ...

2001-12-21

401

Production of rare earth enriched isotopes and americium 242 using metallphthalocyanines  

International Nuclear Information System (INIS)

A technique of producing radioactive isotopes of rare earth elements (r.e.e.) and carrier free "2"4"2Am is suggested. The technique makes use of ''sandwich'' phthalocya=- nine complexes of r.e.e. and americium placed on sorbent. This is a new type of r.e.e. compounds and actinides (C_3_2H_1_6N_8)_2M (M is a metal ion) which are thermally, radiationally and chemically stable, dissolve well in some organic solvents and do not dissolve in water. Radiation and chemically stable activated carbon is used as a sorbent carrier. After irradiation the target is treated by a weakly acid solution or complex-former solution. Radioactive atoms formed due to (n, #gamma#)-reaction and desoleting the complex because of recoil transfer into the solution. When irradiating in the flux of 10"1"3 neutr./cm"2 x s for 1 hour it is possible to produce radioactive isotopes with the yield from 20 to 90%, for example "1"6"0Tb, ...

402

Optimisation of imaging technique used in direct digital radiography  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion from being reached. The fact that all images were of diagnostic quality, however, ...

2006-09-15

403

Optimisation of imaging technique used in direct digital radiography  

International Nuclear Information System (INIS)

The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion from being reached. The fact that all images were of diagnostic quality, however, ...

2006-09-01

404

Electric field measurement on time domain generated by corona on insulators on distribution systems  

Energy Technology Data Exchange (ETDEWEB)

Radio interference and TV interference are being a problem in urban and rural areas. This interference is generated by high voltage transmission lines as well as distribution lines. The radio noise can be produced by polluted or damaged insulators, and by metal parts of the distribution lines. The corona effect on the surface of the dielectric material produces high frequency electromagnetic fields during the ionization and during the recombination period. Fields of different intensity are produced by positive voltage and negative voltage. The insulator flashover (leaking current) also produces electromagnetic fields. A new technique to measure these fields was developed. This technique measures the radiated fields on time domain and on frequency domain. This permits us to characterize the radiated field and thus identify the type of the source. Several measurements were done varying the type of the RF ...

1996-12-31

405

Three-Dimensional Rotational Angiography of the Inferior Vena Cava as an Adjunct to Inferior Vena Cava Filter Retrieval  

International Nuclear Information System (INIS)

The objective of this study was to explore the role of three-dimensional (3-D) rotational angiography (RA) of the inferior vena cava (IVC; 3-D CV) before filter retrieval and its impact on treatment planning compared with standard anteroposterior cavography (sCV). Thirty patients underwent sCV and 3-D CV before IVC filter retrieval. Parameters assessed were: projection of filter arms or legs beyond the caval lumen, thrombus burden within the filter and IVC, and orientation of the filter within IVC. Skin and effective radiation doses were calculated. Statistical analysis was performed using paired Student t test and nonparametric McNemar's test. Standard anteroposterior cavography detected 49 filter arms or legs projecting beyond the caval lumen in 25 patients. Three-dimensional CV demonstrated 89 filter arms or legs projecting beyond the caval lumen in 28 patients. Twenty-two patients had additional filter arms or legs projecting beyond the ...

2009-01-01

406

Thulium-doped vanadate crystals: Growth, spectroscopy and laser performance  

British Library Electronic Table of Contents (United Kingdom)

This work is concentrated on growth, spectroscopy and laser performance of thulium-doped vanadate crystals. At the beginning the growth techniques are analyzed and then the matrix of vanadates crystal, its structure and physicochemical properties are explained together with the rare earth activators influence. Detailed spectroscopy of the thulium-doped vanadate crystals then follows. On the background of this theoretical analysis and state of the art of the subject the description of thulium vanadate lasers (especially Tm:YVO"4, Tm:GdVO"4, and Tm:LuVO"4) together with their generated output radiation characteristics are presented.

2011-01-01

407

The effects of gamma irradiation of food contact plastics on the extent of migration of hindered phenol antioxidants into fatty food simulants  

International Nuclear Information System (INIS)

In view of the interest in the use of gamma irradiation to extend the storage life of pre-packaged foods a report is made on the effects of gamma radiation on the migration of Irganox 1076 and Irganox 1010, antioxidants present in food packaging plastics, into synthetic triglyceride fatty-food simulant HB307 and iso-octane. The extent of migration was assayed by h.p.l.c. techniques. Migration into HB307 and iso-octane decreased steadily as irradiation progressed suggesting that gamma irradiation of packaging materials helps to prevent the contamination of food by antioxidants in the packaging. (U.K.).

408

The course, diagnosis and treatment of Ewing's sarcoma of the rib in children  

International Nuclear Information System (INIS)

Advances in the diagnosis of Ewing's sarcoma of the rib were considered and retrospective analysis of the treatment of 32 patients (76% of them were children at the age of 10-15 y.o.) in the clinic of children oncology was performed. It was shown that the diagnosis of Ewing's sarcoma of the rib in children ought to be combined taking into account the course, morphology and radiation examination techniques. Most optimum treatment consisted of combined therapy (cyclic polychemotherapy, lesion focus irradiation at the summary focus dose of 57 Gy, surgery with subsequent polychemotherapy for not less than 1.5 years

1997-11-18

409

Overview of bunch length measurements.  

Energy Technology Data Exchange (ETDEWEB)

An overview of particle and photon beam bunch length measurements is presented in the context of free-electron laser (FEL) challenges. Particle-beam peak current is a critical factor in obtaining adequate FEL gain for both oscillators and self-amplified spontaneous emission (SASE) devices. Since measurement of charge is a standard measurement, the bunch length becomes the key issue for ultrashort bunches. Both time-domain and frequency-domain techniques are presented in the context of using electromagnetic radiation over eight orders of magnitude in wavelength. In addition, the measurement of microbunching in a micropulse is addressed.

1999-02-19

410

Nuclear fuel behavior at an atomic scale: the contributions of the ab initio calculations and the synchrotron radiation; Comportement du combustible nucleaire a l'echelle atomique: les apports des calculs ab initio et du rayonnement synchrotron  

Energy Technology Data Exchange (ETDEWEB)

This paper presents fundamental researches based on the electronic structure calculations and X absorption spectroscopy, allowing the knowledge on nuclear fuels at an atomic scale. They bring a better understanding of these material behavior to accurate the macroscopic simulation. The calculation methods, the experimental techniques of validation and the ab initio calculations results are detailed. (A.L.B.)

2000-07-01

411

Megavoltage electron beam therapy in the treatment of basal and squamous cell carcinomata of the pinna  

Energy Technology Data Exchange (ETDEWEB)

Forty-three patients with basal and squamous cell carcinomata arising on the pinna were treated radically using a 10 MeV electron beam. The technique and dosage are described and discussed. Primary cancer control with retention of the pinna was achieved in 34 patients. Salvage pinnectomy was performed in four patients for recurrence and one patient for radiation necrosis. Two patients with large primary tumours failed to resolve and died of their disease. The advantages for the patient of the policy of primary radical electron beam therapy are discussed.

1982-05-01

412

Differential anomalous-x-ray-scattering study of icosahedral and amorphous Pd/sub 58.8/U/sub 20.6/Si/sub 20.6/  

International Nuclear Information System (INIS)

The total and differential atomic pair-correlation functions of an icosahedral (quasicrystalline) solid were determined for the first time, directly by the differential anomalous-x-ray-scattering technique using synchrotron radiation. The observed atomic distances involving uranium atoms in icosahedral Pd/sub 58.8/U/sub 20.6/Si/sub 20.6/ suggest the presence of a quasicrystalline sublattice with vertex decoration. The pair distribution functions in the icosahedral and amorphous phases are similar up to the second-nearest neighbors, or up to 6 A-circle.

413

Differential anomalous-x-ray-scattering study of icosahedral and amorphous Pd/sub 58. 8/U/sub 20. 6/Si/sub 20. 6/  

Energy Technology Data Exchange (ETDEWEB)

The total and differential atomic pair-correlation functions of an icosahedral (quasicrystalline) solid were determined for the first time, directly by the differential anomalous-x-ray-scattering technique using synchrotron radiation. The observed atomic distances involving uranium atoms in icosahedral Pd/sub 58.8/U/sub 20.6/Si/sub 20.6/ suggest the presence of a quasicrystalline sublattice with vertex decoration. The pair distribution functions in the icosahedral and amorphous phases are similar up to the second-nearest neighbors, or up to 6 A-circle.

1986-07-07

414

Development and utilization of the nominal standard dose for the tolerance dose to sound tissue with radiation t: m1herapy  

International Nuclear Information System (INIS)

The utilization of the Ellis-formula for the determination of the tolerance of normal connective tissue is described. Beyond this, the formula is adapted to so-called critical organs. The individual suppositions implicated by the Ellis-formula are commented. Because of the verifyable congruency of the Ellis-formula with data obtained in clinical practice also by other authors, this conception is presented for the provisional determination of the limits of tolerance of normal tissue together with a computerized programme elaborated for use in different therapeutic techniques. (orig.).

1976-01-01

415

Determination of the cell and mucous distribution in the airways of the lung  

International Nuclear Information System (INIS)

Models of the human airways have played a major role in evaluating the health effects of inhaled radionuclides. While models such as those of Weibel (1963) provide data necessary for characterizing deposition of aerosol, they have not characterized the cells at risks in the airspaces. Given the advancements in techniques and study of cell cultures exposed to ionizing radiation there is a need to extrapolate between the simple structures of cell culture systems and the complex architecture of the human airways. The preliminary data in this paper provide a complete characterization of the size and number of cells in the airways and represents a significant advance in our study of the health consequences of exposure to inhaled radionuclides. 26 refs., 2 figs., 4 tabs.

1991-01-01

416

Sequence analysis of the ATM gene in 20 patients with RTOG grade 3 or 4 acute and/or late tissue radiation side effects  

International Nuclear Information System (INIS)

Purpose: Patients with ataxia-telangiectasia (A-T) show greatly increased radiation sensitivity and cancer predisposition. Family studies imply that the otherwise clinically silent heterozygotes of this autosomal recessive disease run a 3.5 to 3.8 higher risk of developing cancer. In vitro studies suggest moderately increased cellular radiation sensitivity of A-T carriers. They may also show elevated clinical radiosensitivity. We retrospectively examined patients who presented with severe adverse reactions during or after standard radiation treatment for mutations in the gene responsible for A-T, ATM, considering a potential means of future identification of radiosensitive individuals prospectively to adjust dosage schedules. Material and Methods: We selected 20 cancer patients (breast, 11; rectum, 2; ENT, 2; bladder, 1; prostate, 1; anus, 1; astrocytoma, 1; Hodgkins lymphoma, 1) with Grade 3 to 4 (RTOG) acute and/or late ...

1999-07-15

417

Thermal Design and Performance of the Gamma-Ray Spectrometer for the MESSENGER Spacecraft  

Energy Technology Data Exchange (ETDEWEB)

A gamma-ray spectrometer (GRS) has been built and delivered to the Mercury MESSENGER spacecraft which launched on August 3, 2004, from Cape Canaveral, Florida. The GRS, a part of seven scientific instruments on board MESSENGER, is based on a coaxial high-purity germanium detector. Gamma-ray detectors based on germanium have the advantage of providing excellent energy resolution, which is critical to achieving the science goals of the mission. However, germanium has the disadvantage that it must operate at cryogenic temperatures (typically {approx}80 K). This requirement is easy to satisfy in the laboratory but difficult near Mercury, which has an extremely hot thermal radiation environment. To cool the detector, a Stirling cycle mechanical cooler is employed. In addition, radiation and conduction techniques a are used to reduce the GRS heat load. Before delivering the flight sensor, a complete thermal prototype was built ...

2004-10-13

418

The dust distribution in edge-on galaxies. Radiative transfer fits of V and K'-band images  

CERN Document Server

Aims: I have analyzed a sample of seven nearby edge-on galaxies observed in the V and K'-band, in order to infer the properties of the dust distribution. Methods: A radiative transfer model, including scattering, have been used to decompose each image into a stellar disk, a bulge, and a dust disk. The parameters describing the distributions have been obtained through standard X^2 minimization techniques. Results: The dust disks fitted to the V-band images are consistent with previous work in literature: the radial scalelength of dust is larger than that for stars (h_d/h_s ~ 1.5); the dust disk has a smaller vertical scalelength than the stellar (z_d/z_s ~ 1/3); the dust disk is almost transparent when seen face-on (central, face-on, optical depth tau_0 =0.5-1.5). Faster radiative transfer models which neglect scattering can produce equivalent fits, with changes in the derived parameters within the accuracy of full fits ...

2007-01-01

419

TLD array for precise dose measurements in stereotactic radiation techniques  

International Nuclear Information System (INIS)

We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and calculated data at full width at half maximum. This TLD array may be ...

1996-12-01

420

Severe rectal injury following radiation for prostatic cancer  

Energy Technology Data Exchange (ETDEWEB)

Between 1970 and 1981, 348 patients underwent definitive irradiation. Of these patients 6 (1.7 per cent) sustained severe rectal injury as manifest by major rectal bleeding, rectal stricture, rectal mucosal slough and rectal ulceration. Severe rectal injury was observed in 0 of 13 patients (0 per cent) treated with 125iodine, 3 of 329 (1 per cent) treated with 6,400 to 6,800 rad external irradiation, 2 of 39 (5 per cent) treated with 7,000 to 7,300 rad external irradiation, and 1 of 7 (14 per cent) treated with 198gold and external irradiation. The impact of radiation dose, radiation therapy technique and surgical trauma was assessed. Rectal injury was managed by supportive measures in 2 patients and by diverting colostomy in 3 with benefit. One patient underwent abdominoperineal resection. A small bowel fistula and an intra-abdominal abscess developed, and the patient died.

1984-04-01

421

Selective absorption of ultraviolet laser energy by human atherosclerotic plaque treated with tetracycline  

Energy Technology Data Exchange (ETDEWEB)

Tetracycline is an antibiotic that absorbs ultraviolet light at 355 nm and preferentially binds to atherosclerotic plaque both in vitro and in vivo. Tetracycline-treated human cadaveric aorta was compared with untreated aorta using several techniques: absorptive spectrophotometry; and tissue uptake of radiolabeled tetracycline, which showed 4-fold greater uptake by atheroma than by normal vessel. In addition, intravenous tetracycline administered to patients undergoing vascular surgery demonstrated characteristic fluorescence in surgically excised diseased arteries. Because of tetracycline's unique properties, the authors exposed tetracycline-treated and untreated aorta to ultraviolet laser radiation at a wavelength of 355 nm. They found enhanced ablation of tetracycline-treated atheroma compared with untreated atheroma. The plaque ablation caused by ultraviolet laser radiation was twice as extensive in ...

1985-05-01

422

Remote Sensing and In-Situ Observations of Arctic Mixed-Phase and Cirrus Clouds Acquired During Mixed-Phase Arctic Cloud Experiment: Atmospheric Radiation Measurement Uninhabited Aerospace Vehicle Participation  

Energy Technology Data Exchange (ETDEWEB)

The Atmospheric Radiation Monitor (ARM) uninhabited aerospace vehicle (UAV) program aims to develop measurement techniques and instruments suitable for a new class of high altitude, long endurance UAVs while supporting the climate community with valuable data sets. Using the Scaled Composites Proteus aircraft, ARM UAV participated in Mixed-Phase Arctic Cloud Experiment (M-PACE), obtaining unique data to help understand the interaction of clouds with solar and infrared radiation. Many measurements obtained using the Proteus were coincident with in-situ observations made by the UND Citation. Data from M-PACE are needed to understand interactions between clouds, the atmosphere and ocean in the Arctic, critical interactions given large-scale models suggest enhanced warming compared to lower latitudes is occurring.

2005-03-18

423

Effects of irradiation in medicinal and eatable herbs  

International Nuclear Information System (INIS)

For ages, herbs have been used as medicine and food. Nowadays, the interest in phytotherapeutics is increasing as well as the consumer attention. Some biochemical compounds synthesized by plants as alkaloids, phenolics, flavonoids, essential oils, tannins and vitamins, influence the composition of these plant pharmacologicals, which may produce various reactions in the human body. The microbial contamination in these raw plant materials is common, and the radiation processing is one appropriate technique for the reduction of microorganism. In herbs used as food products, the changes in total #beta#-carotene and flavonoids upon the radiation treatment were tested. The powdered and dehydrated herbs were irradiated with "6"0Co gamma rays applying doses of 0, 10, 20 and 30 kGy. The botanical species investigated were rosemary (Rosmarinus officinalis Linne), watercress (Nasturtium officinale R. Br), artichoke (Cynara scolymus ...

2002-03-01

424

Chemical, sensory and microbiological changes of gamma irradiated coconut cream powder  

Energy Technology Data Exchange (ETDEWEB)

A study was carried out to determine optimum decontamination dose for a locally manufactured coconut cream powder. Samples were gamma irradiated (0-15 kGy) and ageing process was achieved using GEER oven at 60 deg. C for 7 days, which is equivalent to one-year storage at room temperature. Iodine value (IV), ranging from 4.8 to 6.4, was not affected by radiation doses and storage, however peroxide value and thiobarbituric acid (TBA) generally increased with radiation doses. In most samples, peroxide value (meq/kg) reduced after storage, whilst the TBA (mg malonaldehyde/kg), indicator for product quality, slightly increased. The sensory evaluation conducted using 25 taste panellists indicated that scores on odour, creamy taste and overall acceptance for all irradiated samples at more than 5 kGy were significantly lower (P<0.05) than the control. However, the panellists could not detect any significant differences among ...

2007-11-15

425

Single exposure energy subtraction chest radiography in the diagnosis of pulmonary cancer  

Energy Technology Data Exchange (ETDEWEB)

A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is considered to be one of the routine examinations, in view of low ...

1987-03-01

426

Single exposure energy subtraction chest radiography in the diagnosis of pulmonary cancer  

International Nuclear Information System (INIS)

A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is considered to be one of the routine examinations, in view of low ...

1987-01-01

427

Non-Destructive Testing of Bus-Bar Joints Powering LHC Superconducting Magnets, by Using Gamma Sources  

CERN Document Server

The main LHC superconducting magnets (dipoles and quadrupoles) use Rutherford type cables, stabilized electrically and thermally with copper profiles. The portions of cables are connected to each other by a soft soldering technique (Sn96Ag4) with an overlapping length corresponding to one pitch of the superconducting strands. The splice constitutes a "composite" structure with the interchanging layers of Sn96Ag4 and NbTi superconductor, located inside a Cu cage. In order to ensure a high level of reliability (failure probability not exceeding 10-8) for some 10000 connections in the LHC, a non-destructive technique to check the quantity of solder in the joint is foreseen. The technique is based on a gamma ray source (241Am) and the detection is position-sensitive in the transmission mode. Scintillating detectors of gamma rays are used and their accumulated length corresponds to the length of the ...

2004-01-01

428

Measurement of in-situ stress in salt and rock using NQR techniques  

Energy Technology Data Exchange (ETDEWEB)

A discussion of how stress and strain affect the quantities which can be measured in an NQR experiment shows that, for stresses of the magnitude to be expected at depths up to about 10,000 feet, quadrupole coupling constants will fall in the range of 1 to 10 kHz for both the sodium and chloride ions in NaCl. The most promising system involves pulsed nuclear double resonance detection; and alterative is to observe the quadrupolar splitting of the NMR signal. Choices to be made in the measurement and mapping techniques are discussed. The well-known perturbation of the homogenous stress field in the neighborhood of a borehole is shown to be advantageous from the point of view of obtaining directional information on the stress. Construction and operation of a borehole stress sensor are considered. The NQR technique seems feasible for measuring the magnitude and direction of underground stress with a resolution of about 25 psi, ...

1980-12-01

429

CT versus MRI in the study of the articular diseases of the knee  

International Nuclear Information System (INIS)

The authors present a comparison between the diagnostic accuracy of Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) in the articular pathologies of the knee. CT and MRI were performed in 30 patients who subsequently underwent surgery. CT and MRI results were compared on three bases: technique, definition of normal anatomy, and diagnostic accuracy. CT allowed a standardization of the technique, while MRI was superior in defining normal anatomy - especially in the study of capsulo-ligamentous structures. In all cases the use of both CT and MRI allowed a correct diagnosis, showing the site, extent and gravity of the lesion. CT proved to be superior to MRI in 4 cases, while MRI corrected CT diagnosis in 11 cases; in 15 patients both techniques had the same diagnostic accuracy. Meniscal tears were better identified by CT, while MRI was superior in the detection of ligamentous lesions and in the ...

1988-01-01

430

A novel approach to personal photo album representation and management  

Science.gov (United States)

In this paper we present a novel approach to personal photo album management allowing the end user to efficiently access the collection without any need for tedious manual annotation or indexing of the photos. The proposed work exploits methods and technology from the field of computer vision and pattern recognition for face detection, face representation and image annotation to automatically create description of images useful for content-based searching and retrieval. In fact, even if most of the used techniques are not reliable enough to address the general problem of content-based image retrieval, we show that, in a limited domain such as the one of personal photo album, it is possible to obtain results that improve the browsing capabilities of current photo album management systems. In particular, starting from the observation that most personal photos depict a usually small number of people in a relatively small number of different ...

2008-01-01

431

A comparison of algorithms for inference and learning in probabilistic graphical models.  

Science.gov (United States)

Research into methods for reasoning under uncertainty is currently one of the most exciting areas of artificial intelligence, largely because it has recently become possible to record, store, and process large amounts of data. While impressive achievements have been made in pattern classification problems such as handwritten character recognition, face detection, speaker identification, and prediction of gene function, it is even more exciting that researchers are on the verge of introducing systems that can perform large-scale combinatorial analyses of data, decomposing the data into interacting components. For example, computational methods for automatic scene analysis are now emerging in the computer vision community. These methods decompose an input image into its constituent objects, lighting conditions, motion patterns, etc. Two of the main challenges are finding effective representations and models in specific applications and finding efficient algorithms ...

2005-09-01

432

Computed tomography of the orbit  

Energy Technology Data Exchange (ETDEWEB)

In less than a decade computed tomography (CT scanning) had a profound impact on diagnostic radiology. Radiology of the orbit is no exception. As early as 1973, reports published in the radiological literature indicated that this new noninvasive imaging method was a highly effective way of demonstrating intraorbital mass lesions. As CT scanners became widely available, computed tomography became a significant adjunct to ophthalmological diagnosis. Today the main indications for CT scanning of the orbit are: (1) suspected mass lesions, most frequently presenting as exophthalmos, (2) orbital trauma, including foreign bodies, (3) some congenital anomalies, and (4) suspicion of extension into the orbit of extraorbital disease processes. Along with ultrasonography, another new noninvasive imaging technique, CT has replaced a number of more invasive and often less effective diagnostic methods, such as orbital pneumography, venography, and arteriography as major imaging ...

1981-01-01

433

An investigation of the production of thin films of some materials which undergo phase transitions for optical applications  

CERN Document Server

The aim of this work was to study the possibility of producing a fast switching optical thin film device to react to laser radiation in the visible/near infrared region of the spectrum. The switching mechanism was to be thermally driven. A computer program was written to enable the effects of changes of the refractive index of a component of a multilayer thin film stack to be modelled. Attempts to use the phase transition in vanadium dioxide were unsuccessful because, in the spectral region of interest, the 'open-state' absorption was too great. A class of materials known as 'the bronzes' was identified as being potentially useful. Attempts were made to produce thin films of bronze compounds of vanadium, tungsten and molybdenum by the techniques of conventional thermal evaporation and laser ablation for further studies. The former technique appeared to suffer from problems of decomposition of the source material. The latter ...

1995-01-01

434

X-ray, Optical, and Radio Observations of SN 1999em and SN 1998S  

CERN Document Server

Observations of the Type II-P (plateau) Supernova (SN) 1999em and Type IIn (narrow emission line) SN 1998S have enabled estimation of the profile of the SN ejecta, the structure of the circumstellar medium (CSM) established by the pre-SN stellar wind, and the nature of the shock interaction. SN 1999em is the first and only Type II-P detected at both X-ray and radio wavelengths. It is the least radio luminous and one of the least X-ray luminous SN ever detected (except for the unusual and very close SN 1987A). The Chandra X-ray data indicate non-radiative interaction of SN ejecta with a power-law density profile (rho \\propto r^{-n} with n ~ 7) with a pre-SN wind with a low mass loss rate of ~2 \\times 10^{-6} Msun/yr for a wind velocity of 10 km/sec, in close agreement with radio mass-loss rate estimates. The Chandra data show an unexpected, temporary rise in the 0.4--2.0 keV X-ray flux at ~100 days after explosion. SN ...

2001-01-01

435

The influence of salt aerosol on alpha radiation detection by WIPP continuous air monitors  

Energy Technology Data Exchange (ETDEWEB)

Alpha continuous air monitors (CAMs) will be used at the Waste Isolation Pilot Plant (WIPP) to measure airborne transuranic radioactivity that might be present in air exhaust or in work-place areas. WIPP CAMs are important to health and safety because they are used to alert workers to airborne radioactivity, to actuate air-effluent filtration systems, and to detect airborne radioactivity so that the radioactivity can be confined in a limited area. In 1993, the Environmental Evaluation Group (EEG) reported that CAM operational performance was affected by salt aerosol, and subsequently, the WIPP CAM design and usage were modified. In this report, operational data and current theories on aerosol collection were reviewed to determine CAM quantitative performance limitations. Since 1993, the overall CAM performance appears to have improved, but anomalous alpha spectra are present when sampling-filter salt deposits are at normal to high levels. This report shows that ...

1996-01-01

436

Reactivity differences of hydroxyl radicals and hydrated electrons in destructing azo dyes  

International Nuclear Information System (INIS)

The high-energy radiation-induced degradation of an H-acid derivative azo dye, Apollofix-Red SF-28 (AR-28) was studied in aqueous solution by using pulse radiolysis with kinetic spectroscopic detection for transient measurements. Gamma radiolysis with UV-VIS spectroscopy and gradient ionpair HPLC separation with diode array detection were applied for following the destruction of AR-28 and measuring the products. The reactions of hydrated electron (e_a_q "-) and hydroxyl ("#centre dot#OH) radical were investigated separately. "#centre dot#OH reacts with the unsaturated bonds of the molecule. In the further reactions of the "#centre dot#OH adduct radicals, the AR-28 molecules partly reform with a slightly modified structure. The products formed in the first reaction of "#centre dot#OH and AR-28 molecules have also high reactivity towards the "#centre dot#OH radicals. For these reasons the efficiency of "#centre dot#OH ...

437

High resolution Computed Tomography in the study of temporal bone trauma  

International Nuclear Information System (INIS)

Thirty-five patients with temporal bone fractures were examined; the fractures were sometimes associated with dislocation of the assicular chain caused by road fatalities. Computed Tomography (CT) was performed either because of the presence of clinical symptoms associated with trauma of the temporal bone, because of a hemotympanum discovered during a CT scan of the brain. Thirty-three fractures were detected: 19 longitudinal, 6 transverse, and 8 complex. An incudostapedial dislocation was also detected, together with a displacement of a stapedial prosthesis from the lenticular process of incus, and 3 incus-malleus dislocation associated with fractures. High resolution CT allows the precise definition of the course of the fractures, of the associated dislocation of the ossicular chain, and of facial nerve lesion, thus allowing a more accurate surgical intervention. In the examination of the temporal bone, high resolution CT is preferible to ...

1988-01-01

438

Detecting exposure to environmental organic toxins in individual cells: towards development of a micro-fabricated device  

Energy Technology Data Exchange (ETDEWEB)

A new method is being developed to quickly screen for the human exposure potential to polycyclic aromatic hydrocarbons (PAHs) and organochlorines (OCs). The development involves two key elements: identifying suitable signals that represent intracellular changes that are specific to PAH and OC exposure, and constructing a device to guide the biological cell growth so that signals from individual cells are consistent and reproducible. We are completing the identification of suitable signals by using synchrotron radiation-based (SR) Fourier-transform infrared (FTIR) spectromicroscopy in the mid-infrared region (4000-400 cm-1). Distinct changes have been observed in the IR spectra after treatment of human cells in culture medium with PAHs and OCs. The potential use of this method for detecting exposure to PAHs and OCs has been tested and compared to a reverse transcription polymerase chain reaction (RT-PCR) assay that quantifies increased ...

1999-01-10

439

Automated method for determining location and magnitude of leaks inside a PWR containment  

Energy Technology Data Exchange (ETDEWEB)

Thermal-hydraulics analysis can be used to determine location and magnitude of leaks inside a pressurized water reactor (PWR) containment, as required by plant technical specifications. The major advantage of this detection method is that it minimizes radiation exposure of maintenance personnel because most of the leak detection process is performed from the control room outside the containment. In addition, such a program allows for the elimination of pipe whip restraints and jet impingement shields, eliminating costs for maintenance of these supports and shields in older plants and lowering construction costs for new plants. Previously, only simple single-node containment models were used for determining leakage magnitude. This paper presents a more sophisticated multinode approach for determining the magnitude and location. The resulting sensitivities to leak can be programmed into the plant's computer system. ...

1986-01-01

440

Detection by cationized /sup 125/I-cytochrome C of proteoglycans (PG) transferred to nylon  

Energy Technology Data Exchange (ETDEWEB)

Cytochrome c, labeled with /sup 125/I, has been used by us for staining glycosaminoglycans (GAG) separated by electrophoresis on cellulose acetate strips. As GAG between 1-10 ng could be quantified by autoradiography and densitometry, the reagent is approximately 100-fold more sensitive than currently used non-radiolabeled stains. The authors extend now the use of radiolabeled cytochrome c to the quantification of PG transblotted to solid supports subsequent to separation on polyacrylamine slab gels. Dot blotting used for exploring optimal conditions for detecting PG indicated that because of low background positively charged Nylon 66 was superior to nitrocellulose. Increasing the positive charge of the staining reagent by cationization decreased background radiation even further so that 1 ng PG could be seen readily after 5 hrs of autoradiography. Use of cationized /sup 125/I-cytochrome c has been made in detecting PG of ...

1986-05-01

441

An Assessment of the Detection of Highly Enriched Uranium and its Use in an Improvised Nuclear Device using the Monte Carlo Computer Code MCNP-5  

Science.gov (United States)

In 2002 and again in 2003, an investigative journalist unit at ABC News transported a 6.8 kilogram metallic slug of depleted uranium (DU) via shipping container from Istanbul, Turkey to Brooklyn, NY and from Jakarta, Indonesia to Long Beach, CA. Targeted inspection of these shipping containers by Department of Homeland Security (DHS) personnel, included the use of gamma-ray imaging, portal monitors and hand-held radiation detectors, did not uncover the hidden DU. Monte Carlo analysis of the gamma-ray intensity and spectrum of a DU slug and one consisting of highly-enriched uranium (HEU) showed that DU was a proper surrogate for testing the ability of DHS to detect the illicit transport of HEU. Our analysis using MCNP-5 illustrated the ease of fully shielding an HEU sample to avoid detection. The assembly of an Improvised Nuclear Device (IND) -- a crude atomic bomb -- from sub-critical pieces of HEU metal was then examined ...

2007-04-01

442

Gamma and X-ray shielding compositions utilizing bauxite - Red Mud regional research laboratory (CSIR), Bhopal, India  

International Nuclear Information System (INIS)

Available in abstract form only. Full text of publication follows: The application spectrum of X-ray and Gamma radiation is increasing exponentially in the area of diagnostic, nuclear medicine, food preservation, nuclear power plants and strategic utilities. To prevent the harmful effects of these radiations, shielding materials based on lead metal and its compounds are being used historically, which are toxic in nature. To protect environment it has become necessary to develop non-toxic lead free shielding materials. The use of titanium metal and its compounds as synthetic rock i.e. SYNROC are reported to be very effective non-toxic shielding materials for various applications. Red mud waste generated in aluminum producing industries possesses a unique mineralogical compositions containing fairly high quantity of titanium oxide and iron oxide useful for making non toxic shielding compositions and therefore red mud has been utilized for the ...

2007-09-02

443

Analysis of coupled neutron-gamma radiations, applied to shieldings in multigroup albedo method; Analise das radiacoes neutron e gama acopladas, aplicada a blindagem com varias camadas pelo metodo multigrupo do albedo  

Energy Technology Data Exchange (ETDEWEB)

The principal mathematical tools frequently available for calculations in Nuclear Engineering, including coupled neutron-gamma radiations shielding problems, involve the full Transport Theory or the Monte Carlo techniques. The Multigroup Albedo Method applied to shieldings is characterized by following the radiations through distinct layers of materials, allowing the determination of the neutron and gamma fractions reflected from, transmitted through and absorbed in the irradiated media when a neutronic stream hits the first layer of material, independently of flux calculations. Then, the method is a complementary tool of great didactic value due to its clarity and simplicity in solving neutron and/or gamma shielding problems. The outstanding results achieved in previous works motivated the elaboration and the development of this study that is presented in this dissertation. The radiation balance ...

2002-07-01

444

Analysis of coupled neutron-gamma radiations, applied to shieldings in multigroup albedo method  

International Nuclear Information System (INIS)

The principal mathematical tools frequently available for calculations in Nuclear Engineering, including coupled neutron-gamma radiations shielding problems, involve the full Transport Theory or the Monte Carlo techniques. The Multigroup Albedo Method applied to shieldings is characterized by following the radiations through distinct layers of materials, allowing the determination of the neutron and gamma fractions reflected from, transmitted through and absorbed in the irradiated media when a neutronic stream hits the first layer of material, independently of flux calculations. Then, the method is a complementary tool of great didactic value due to its clarity and simplicity in solving neutron and/or gamma shielding problems. The outstanding results achieved in previous works motivated the elaboration and the development of this study that is presented in this dissertation. The radiation balance ...

2002-01-01

445

Whole-body counting in the Marshall Islands  

Energy Technology Data Exchange (ETDEWEB)

In 1978 the Marshall Islands Radiological Safety Program was organized to perform radiation measurements and assess radiation doses for the people of the Bikini, Enewetak, Rongelap and Utirik Atolls. One of the major field components of this program is whole- body counting (WBC). WBC is used to monitor the quantity of gamma- emitting radionuclides present in individuals. A primary objective of the program was to establish {sup 137}Cesium body contents among the Enewetak, Rongelap and Utirik populations. {sup 137}Cs was the only gamma-emitting fission radionuclide detected in the 1,967 persons monitored. {sup 137}Cs body burdens tended to increase with age for both sexes, and were higher in males. The average {sup 137}Cs dose Annual Effective Dose for the three populations was as follows: For Enewetak, the dose was 22{+-}4 {mu}Sv. For Utirik, the dose was 33{+-} 3 {mu}Sv. Since 1985 the Rongelap people have been self-exiled ...

1991-01-01

446

Utilization of CTR to measure the evolution of electron-beam microbunching in a self-amplified spontaneous emission (SASE) free-electron laser (FEL)  

International Nuclear Information System (INIS)

We report on the first measurements of the z-dependent evolution of electron-beam microbunching as revealed through coherent transition radiation (CTR) measurements in a visible self-amplified spontaneous emission free-electron laser experiment. The increase in microbunching was detected by tracking the growth of the visible CTR signals as generated from insertable metal mirrors/foils after each of the last three undulators. The same optical imaging diagnostics that were used to track the z-dependent intensity of the undulator radiation (UR) were also used to track the electron beam/CTR information. Angular distribution, beam size, and intensity data were obtained after each of the last three undulators in the five-undulator series, and spectral information was obtained after the last undulator. The exponential growth rate of the CTR was found to be very similar to that of the UR and consistent with simulations using the ...

2002-07-01

447

Utilization of CTR to measure the evolution of electron-beam microbunching in a self-amplified spontaneous emission (SASE) free-electron laser (FEL)  

International Nuclear Information System (INIS)

We report on the first measurements of the z-dependent evolution of electron-beam microbunching as revealed through coherent transition radiation (CTR) measurements in a visible self-amplified spontaneous emission free-electron laser experiment. The increase in microbunching was detected by tracking the growth of the visible CTR signals as generated from insertable metal mirrors/foils after each of the last three undulators. The same optical imaging diagnostics that were used to track the z-dependent intensity of the undulator radiation (UR) were also used to track the electron beam/CTR information. Angular distribution, beam size, and intensity data were obtained after each of the last three undulators in the five-undulator series, and spectral information was obtained after the last undulator. The exponential growth rate of the CTR was found to be very similar to that of the UR and consistent with simulations using the ...

2001-12-21

448

Synchrotron Self-Compton Analysis of TeV X-ray Selected BL Lacertae Objects  

CERN Document Server

We introduce a methodology for analysis of multiwavelength data from X-ray selected BL Lac (XBL) objects detected in the TeV regime. By assuming that the radio--through--X-ray flux from XBLs is nonthermal synchrotron radiation emitted by isotropically-distributed electrons in the randomly oriented magnetic field of a relativistic blazar jet, we obtain the electron spectrum. This spectrum is then used to deduce the synchrotron self-Compton (SSC) spectrum as a function of the Doppler factor, magnetic field, and variability timescale. The variability timescale is used to infer the comoving blob radius from light travel-time arguments, leaving only two parameters. With this approach, we accurately simulate the synchrotron and SSC spectrum of flaring XBLs in the Thomson through Klein-Nishina regimes. Photoabsorption by interactions with internal jet radiation and the intergalactic background light (IBL) is included. Doppler ...

2008-01-01

449

Study of degradation diagnosis for low voltage cable aged by thermal and radiation with time domain dielectric spectrometer  

International Nuclear Information System (INIS)

Non-destructive methods of diagnosis for detecting cable degradation by aging are being studied recently for improvement of electric wires and cables. This study examines degradation behaviors of cable sheath and insulation by combined accelerated aging tests applying thermal and radiation stresses simultaneously using a typical low voltage cable. According to experiments, elongation of cross-linked polyethylene insulation deteriorated at a faster rate than PVC sheath did under low doses below 50 Gy/h. Therefore, measurements using a time domain dielectric spectrometer (TDS) were carried out for the purpose of developing a method of degradation diagnosis of insulation. It was found that values of tan#delta# measured at very low frequencies below 0.1 Hz increase in pace with degradation of insulation reflecting the level of degradation more effectively than those measured at frequencies around the commercial frequency. In order to consider ...

2000-05-01

450

Gap-junctional communication of bone marrow stromal cells is resistant to irradiation in vitro  

Energy Technology Data Exchange (ETDEWEB)

Bone marrow is one of the most radiosensitive organs. Irradiation causes a marked decrease in the total number of hematopoietic cells in the bone marrow. The reticular meshwork structure of marrow stromal cells, however, is relatively resistant to irradiation. Unimpaired stromal cell structure has been thought to be a prerequisite for the repopulation of hematopoietic cells during recovery from the effects of irradiation. The reticular framework is maintained by cell adhesion apparatuses such as gap junctions. The in vitro radiobiologic survival values of a cloned stromal cell line, H-1/A, were studied (n = 1.8, D0 = 138 cGy). Radiation doses of up to 4000 cGy had no detectable effects on the production of colony-stimulating factor 1. H-1/A cells communicate with each other via gap junctions as determined by the sensitive dye-transfer method. Gap-junctional communication between H-1/A cells was resistant to different levels of irradiation (500 ...

1990-10-01

451

Gap-junctional communication of bone marrow stromal cells is resistant to irradiation in vitro  

International Nuclear Information System (INIS)

Bone marrow is one of the most radiosensitive organs. Irradiation causes a marked decrease in the total number of hematopoietic cells in the bone marrow. The reticular meshwork structure of marrow stromal cells, however, is relatively resistant to irradiation. Unimpaired stromal cell structure has been thought to be a prerequisite for the repopulation of hematopoietic cells during recovery from the effects of irradiation. The reticular framework is maintained by cell adhesion apparatuses such as gap junctions. The in vitro radiobiologic survival values of a cloned stromal cell line, H-1/A, were studied (n = 1.8, D0 = 138 cGy). Radiation doses of up to 4000 cGy had no detectable effects on the production of colony-stimulating factor 1. H-1/A cells communicate with each other via gap junctions as determined by the sensitive dye-transfer method. Gap-junctional communication between H-1/A cells was resistant to different levels of irradiation (500 ...

452

DOE personnel neutron dosimetry evaluation and upgrade program  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. An Effective Dose ...

1988-10-01

453

Air conditioner for radioactive material handling facility  

Energy Technology Data Exchange (ETDEWEB)

An air conditioner intakes open-air from an open-air intake port to remove sands and sea salt particles by air filters. Then, natural and artificial radioactive particles of less than 1 {mu}m are removed by high performance particulate filters. After controlling the temperature by an air heater or an air cooler, air is sent to each of chambers in a facility under pressure elevation by a blower. In this case, glass fibers are used as the filter material for the high performance particulate filter, which has a performance of more than 99.97% for the particles of 0.3 {mu}m grain size. Since this can sufficiently remove the natural radioactive materials intruded from the outside, a detection limit value in each of the chambers of the facility can be set 10{sup -13} to 10{sup -14} {mu}ci/cm{sup 3} in respect of radiation control. Accordingly, radiation control can be conducted smoothly and appropriately. (I.N.).

1991-04-26

454

TeV gamma-rays from the Northern sky pulsar wind nebulae  

Energy Technology Data Exchange (ETDEWEB)

We estimate the TeV {gamma}-ray fluxes expected from the population of young pulsars in terms of the self-consistent time-dependent hadronic-leptonic model for the high-energy processes inside the pulsar wind nebulae (PWNe). This radiation model is based on the hypothesis of Arons and collaborators who postulate that leptons are accelerated inside the nebulae as a result of resonant scattering on heavy nuclei, which in turn are accelerated in the pulsar wind region or the pulsar inner magnetosphere. Our aim is to find out which PWNe on the northern hemisphere are the best candidates for detection at energies above 60 GeV and 200 GeV by the next generation of low-threshold Cherenkov telescopes.

2005-12-01

455

Synthesis of metallic nanoparticles in SiO{sub 2} matrices; Sintesis de nanoparticulas metalicas en matrices de SiO{sub 2}  

Energy Technology Data Exchange (ETDEWEB)

Metallic nanoparticles was synthesized in SiO{sub 2} matrices by means of a process of two stages. The first one proceeded via sol-gel, incorporating the metallic precursors to the reaction system before the solidification of the matrix. Later on, the samples underwent a thermal treatment in atmosphere of H{sub 2}, carrying out the reduction of the metals that finally formed to the nanoparticles. Then it was detected the presence of smaller nanoparticles than 20 nm, dispersed and with the property of being liberated easily of the matrix, conserving a free surface, chemically reactive and with response to external electromagnetic radiation. The system SiO{sub 2}-Pd showed an important thermoluminescent response. (Author)

2004-07-01

456

Spectroscopy of gadolinium gallium garnet crystals doped with Y b3+ revisited  

International Nuclear Information System (INIS)

The optical spectroscopy measurements of gadolinium gallium garnet (GGG) crystals doped with Yb show evidence of the presence of non-equivalent optical centers with very similar radiative decay rates. The energy level schemes of those centers have been determined on the basis of optical absorption, luminescence and Raman experiments. Crystal field fitting resulted in two sets of slightly different crystal field parameters for two non-equivalent Yb centers. Both sets of parameters describe perfectly the experimentally detected Y b3+ energy levels. Correlation between systematic trends in the experimental energy level schemes and crystal field parameters is discussed.

2010-06-30

457

Reduction of fluoroscopic exposure for the air-contrast barium enema  

Energy Technology Data Exchange (ETDEWEB)

In a fluoroscopic imaging system, image quality and patient dose are both affected by the optical system linking the image intensifier with the video camera. The effect on patient exposure of increasing the optical iris aperture size over that required for other procedures performed on the same imaging system was investigated for the air-contrast barium enema examination. Using a large-area transmission ionisation chamber to monitor the Roentgen-area-product of entrance exposure, a decrease in fluoroscopic radiation of greater than 50% was clinically documented for a fluoroscopic system utilising kVp and mA variable automatic brightness control. For this iris change, the video image was of acceptable quality for positioning and monitoring the patient, and no deleterious effect was detected in the conduct of the air-contrast exam. The availability of a variable-sized operator-selectable iris diaphragm would permit this dose-reduction approach to ...

1983-11-01

458

Radiological considerations of the reactor cover gas processing system at the FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

Radiological and environmental protection experience associated with the reactor cover gas processing system at the Fast Flux Test Facility (FFTF) has been excellent. Personnel radiation exposures received from operating and maintaining the reactor cover gas processing system have been very low, the system has remained free of radioactive particulate contamination through the first seven operating cycles (cesium contamination was detected at the end of Cycle 8A), and releases of radioactivity to the environment have been very low, well below environmental standards. This report discusses these three aspects of fast reactor cover gas purification over the first eight operating cycles of the FFTF (a duration of a little more than four years, from April 1982 through July 1986).

1986-09-24

459

Multielement analysis of air samples. Determination of iron, zinc, lead, and bromine content by the radionuclide X-ray fluorescence analysis  

Energy Technology Data Exchange (ETDEWEB)

Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A /sup 238/Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed.

1981-01-01

460

Instruments for X-ray fluorescence analysis and spectrometry  

International Nuclear Information System (INIS)

The radionuclide X-ray fluorescence analyzer consists of a source changer and a sample changer. "5"5Fe, "1"0"9Cd and "2"4"1Am are used as excitation sources. The radiation is detected with a semiconductor Si(Li) detector. The complete assembly of the apparatus consists of an imagine unit, a keyboard, a floppy disc drive, a printer, a console and a rack with analog and digital electronics. Its multichannel amplitude analyzer consists of power supplies, a high voltage supply, a linear amplifier, an analog-to-digital converter and a computer. The technical specifications are given. The control and data processing system is controlled with an MHB 8080A microprocessor. Software for semiconductor gamma spectrometry and for quantitative gamma spectrometry will be supplied with the equipment. (E.S.). 3 figs., 4 refs.

461

Experiments on determination of damage effect ions "2"2Ne (172 MeV) on UO_2 monocrystals  

International Nuclear Information System (INIS)

Shadow effect was used for investigating damage of uranium dioxide monocrystal. The dependence of shadow minimum parameters on fluence of "2"2Ne ions with 172 MeV energy was followed when detecting fission fragments. Ion dose responsible for sufficient microdamage of lattice structure, included into the classification of heavy ion damage effect on monocrystals was determined. The problem of radiation intensity effect on the character of occurred damages was studied. It was established that macroscopic sample failure, caused by generation of considerable mechanical stresses in monocrystal under beam effect could be observed along with microdamages of lattice structure at ion flux density >10"1"2 cm"-"2Xs"-"1.

462

Evapotranspiration estimation using the Landsat-5 Thematic Mapper image over the Gyungan watershed in Korea  

British Library Electronic Table of Contents (United Kingdom)

Even if there have been efforts to validate remote-sensing-based energy balance models, which provide evapotranspiration (ET) maps over a large spatial scale, few studies have been conducted to validate their performance in Korea. In this study, surface energy balance fluxes including ET were estimated and inter-compared with two different models using the Landsat-5 Thematic Mapper (TM) image over a watershed scale in Korea. While there were larger spatial discrepancies for net radiation, soil heat and sensible heat fluxes on a pixel-by-pixel basis between the two models, relatively smaller spatial discrepancies for the latent heat flux and daily ET were detected. The spatial discrepancies for the daily ET were larger in low topography and dense vegetation ranges. Despite the different par...

2011-01-01

463

Characterization of the combustion of biomass producer gas in a constant volume combustion bomb  

British Library Electronic Table of Contents (United Kingdom)

In this article a methodology is presented for studying the influence of the biomass moisture content and the biomass/air ratio on the producer gas composition and on the chemiluminescent emissions during the combustion process. Firstly, a mathematical model based on the thermo-chemical processes inside the gasifier is used to predict the composition of the producer gas as a mixture of CO, CO2, H2, N2, CH4 and H2O gases. Secondly, the predicted composition is introduced into a constant volume combustion bomb (CVCB), which simulates the typical conditions inside the combustion chamber of an internal combustion engine, in order to characterize its combustion under gasoline-type conditions through the instantaneous pressure and the detection of the spontaneous luminous radiation (chemilumines...

2010-01-01

464

A mobile gamma scanning system for detecting radiation anomalies  

Energy Technology Data Exchange (ETDEWEB)

A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A /sup 226/Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.

1983-09-01

465

A mobile gamma scanning system for detecting radiation anomalies  

International Nuclear Information System (INIS)

A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A "2"2"6Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.

466

Ground penetrating radar and direct current resistivity evaluation of the desiccation test cap, Savannah River Site  

Energy Technology Data Exchange (ETDEWEB)

The Savannah River Site (SRS) has a variety of waste units that may be temporarily or permanently stabilized by closure using an impermeable cover to prevent groundwater infiltration. The placement of an engineered kaolin clay layer over a waste unit is an accepted and economical technique for providing an impermeable cover but the long term stability and integrity of the clay in non-arid conditions is unknown. A simulated kaolin cap has been constructed at the SRA adjacent to the Burial Ground Complex. The cap is designed to evaluate the effects of desiccation on clay integrity, therefore half of the cap is covered with native soil to prevent drying, while the remainder of the cap is exposed. Measurements of the continuing impermeability of a clay cap are difficult because intrusive techniques may locally compromise the structure. Point measurements made to evaluate clay integrity, such as those from grid sampling or coring and made through a ...

1996-04-01

467

Low Frequency Phased Array Techniques for Crack Detection in Cast Austenitic Piping Welds: A Feasibility Study  

Energy Technology Data Exchange (ETDEWEB)

Studies conducted at the Pacific Northwest National Laboratory (PNNL) in Richland, Washington have focused on developing and evaluating the reliability of nondestructive testing (NDT) approaches for coarse-grained stainless steel reactor components. The objective of this work is to provide information to the United States Nuclear Regulatory Commission (NRC) on the utility, effectiveness and limitation of NDT techniques as related to inservice testing of primary system piping components in pressurized water reactors. We examined cast stainless steel pipe specimens containing thermal and mechanical fatigue cracks located close to the weld roots and having inner and outer diameter surface geometrical conditions that simulate several water reactor primary piping configurations. In addition, segments of vintage centrifugally cast piping were examined to characterize the inherent acoustic noise and scattering caused by grain structures and to determine the consistency of ...

2007-01-01

468

Kinetics of Pd/sub 2/Si layer growth measured by an x-ray diffraction technique  

Science.gov (United States)

An x-ray diffraction approach has been developed for determination of the kinetics of growth of Pd/sub 2/Si layers. Epitaxial Pd/sub 2/Si films were grown on Si(111) substrates over a temperature range of 160-222/sup 0/C by a solid-state reaction between the substrates and the Pd overlayers. The parabolic rate equation was verified and rate constants showed Arrhenius behavior with an activation energy E/sub a/ = 1.06 eV and prefactor k/sub 0/ = 7 x 10/sup -4/ cm/sup 2//s. The low value of E/sub a/ suggests a short-circuit diffusion mechanism. It is reasonable to expect that impurities and microstructure may play important roles in the growth process. Impurity levels in the specimens were evaluated by analytic techniques suited to thin-film study: Rutherford backscattering spectrometry, secondary ion mass spectrometry, and Auger electron spectrometry. No impurities were present at concentrations approaching 1 at. %. Some O, C, and F were ...

1986-05-15

469

Study of scalar leptons at the TESLA Photon Collider  

International Nuclear Information System (INIS)

In this thesis, the potential to discover supersymmetric signatures in both e"+e"- and #gamma##gamma# colliders evaluated with a Monte Carlo analysis, is discussed. The analysis was focused on the detection of muons, essentially. First, we study the detection of #mu#"+_R#mu#"-_R in e"-e"+ collisions, whose purpose is the measurement of the #mu#_R mass. It was found that an uncertainty of 0.11 GeV (stat) can be achieved. Under the assumption of the real conditions of the ILC photon collider, a study covering the detection of #mu#"+_R#mu#"-_R and #mu#"+_L#mu#"-_L pairs for #sq root#(s_e_"-_e_"+)=0.5 and 0.6 TeV was performed. According to the simulation, a statistical error for the branching ratios of #mu#"#+-#_L#->##chi#"0_1#mu#"#+-# of 0.98% and #mu#"#+-#_L#->##chi#"0_2#mu#"#+-# of 3.97% can be reached. In order to judge the Monte Carlo results, we have used a technique based on a multidimensional ...

470

Immunological detection and quantification of DNA components structurally modified by alkylating carcinogens, mutagens and chemotherapeutic agents  

International Nuclear Information System (INIS)

The detection and quantification of defined reaction products of chemical mutagens and carcinogens (and of many cancer chemotherapeutic agents) with DNA require highly sensitive analytical techniques. The exceptional capability of immunoglobulins to recognize subtle alterations of molecular structure (especially when monoclonal antibodies are used to maximize specificity), outstanding sensitivity of immunoanalysis by high-affinity antibodies, and the fact that radioactively-labelled agents are not required suggest the utility of a radioimmunoassay to recognize and quantitate alkylated DNA products. We have recently developed a set of high-affinity monoclonal antibodies (secreted by mouse x mouse as well as by rat x rat hybridomas; antibody affinity constants, 10"9 to > 10"1"0 lmol) specifically directed against several DNA alkylation products with possible relevance in relation to both mutagenesis and malignant transformation of mammalian ...

1983-09-01

471

Current Status on Stress Diagnostic Kit and Detection Technology  

Energy Technology Data Exchange (ETDEWEB)

The accurate measurement of a stress level is one of the most important issues in a stress diagnosis and its measurement could be of great value in clinical medicine. Stress has a potent effect on the spirit and physical condition of an individual. There are various methods available for its measurement. Some of the commonly used techniques for the diagnosis of a stress level include analysis of the body fluids, questionnaire assessments, psychophysiological evaluations and by determining heart rate variability (HRV) of subjects. However, the existing diagnostic methods have several defects like, a low sensitivity, inaccuracy and long of operation time. In this report, we present a diagnostic technology to detect a stress level which is the origin of various diseases. This method can be of great help in providing an early diagnosis through a biosensor and might play a vital role in preventing diseases like hypochondria and hypertension. ...

2008-06-15

472

Ultrasensitive fluorescence detection of DNA  

Science.gov (United States)

Progress on Ultrasensitive fluorescence detection of DNA is briefly described. (CBS)

1991-01-01

474

Fluorescent Silicate Materials for the Detection of Paraoxon  

Science.gov (United States)

... significantly lower limits of detection. The complex fluorescence spectra of these constructs indicated that only a portion ...

2010-03-19

475

The Use of Medical Images in Planning and Delivery of Radiation Therapy  

UK PubMed Central (United Kingdom)

Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available

1997-09-01

477
478

Animal Models for Radiation Injury, Protection and Therapy  

Science.gov (United States)

... radiation during clinical therapy and exposures due to radiation accidents or attacks, in which the doses are uncontrolled ... only be used off-label in victims of radiation accidents or attacks. The idea...

479

Value of ultrasonography, Ct and MR imaging in the diagnosis of primary hyperparathyroidism  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate the significance of preoperative localization of abnormal parathyroid glands to the surgical outcome in patients with primary hyperparathyroidism. Material and Methods: Thirty-nine patients with primary hyperparathyroidism were studied preoperatively with US (39 patients), CT (30 patients) and MR imaging (18 patients). The overall diagnostic accuracy for US was 87%, CT 66% and MR 94%. In patients with a single parathyroid adenoma US was the most cost-effective localization technique with a detection rate of 96%. CT had a lower detection rate (78%) but was of particular value for fairly large ectopic adenomas in the root of the neck. MR imaging was a good confirmatory test (93%). In patients with multiple gland disease (primary hyperplasia and multiple adenomas), no single localization study alone was sufficient. Combination of all 3 studies, however, alerted the physician to the presence of disease in ...

1996-09-01

480

Performance evaluation for ML sequence detection in ISI channels with Gauss Markov Noise  

CERN Document Server

Inter-symbol interference (ISI) channels with data dependent Gauss Markov noise have been used to model read channels in magnetic recording and other data storage systems. The Viterbi algorithm can be adapted for performing maximum likelihood sequence detection in such channels. However, the problem of finding an analytical upper bound on the bit error rate of the Viterbi detector in this case has not been fully investigated. Current techniques rely on an exhaustive enumeration of short error events and determine the BER using a union bound. In this work, we consider a subset of the class of ISI channels with data dependent Gauss-Markov noise. We derive an upper bound on the pairwise error probability (PEP) between the transmitted bit sequence and the decoded bit sequence that can be expressed as a product of functions depending on current and previous states in the (incorrect) decoded sequence and the (correct) transmitted sequence. In ...

2010-01-01

481

Normal and abnormal water diffusion in the brain  

International Nuclear Information System (INIS)

Diffusion magnetic resonance imaging (MRI) has become an important tool in the radiologic diagnosis of diseases of the brain as it measures molecular motion of water that characterizes the microstructure of tissues. Its most important clinical use to date is the early detection of cerebral ischemia by revealing the ischemic injury shortly after vessel occlusion and simultaneously providing therapy-relevant information on the tissue at risk. Furthermore, diffusion MRI is diagnostically promising in other diseases of the brain and is thus increasingly becoming part of routine clinical protocols in the diagnosis of tumors, inflammation, trauma, demyelination, dysmyelination and neurodegeneration. Although abnormalities of diffusion are generally not pathognomonic, diffusion MRI affords information about tissue changes for specific disorders that complements information obtained with standard MR techniques and frequently shows pathology earlier. In ...

2003-10-01

482

Network security: a survey of modern approaches  

International Nuclear Information System (INIS)

Security is an essential element of information technology (IT) infrastructure and applications. Concerns about security of networks and information systems have been growing along with the rapid increase in the number of network users and the value of their transactions. The hasty security threats have driven the development of security products known as Intrusion Detection Systems (IDS) and Intrusion Prevention Systems (IPS) to detect and protect the network, server and desktop infrastructure ahead of the threat. Authentication and signing techniques are used to prevent integrity threats. Users, devices, and applications should always be authenticated and authorized before they are allowed to access networking resources. Though a lot of information is available on the internet about IDS and IPS but it all is spread on so many sites and one has to spend a considerable part of his precious time to search it. In this regard ...

2008-01-01

483

Network security: a survey of modern approaches  

International Nuclear Information System (INIS)

Security is an essential element of information technology (IT) infrastructure and applications. Concerns about security of networks and information systems have been growing along with the rapid increase in the number of network users and the value of their transactions. The hasty security threats have driven the development of security products known as Intrusion Detection Systems (IDS) and Intrusion Prevention Systems (IPS) to detect and protect the network, server and desktop infrastructure ahead of the threat. Authentication and signing techniques are used to prevent integrity threats. Users, devices, and applications should always be authenticated and authorized before they are allowed to access networking resources. Though a lot of information is available on the internet about IDS and IPS but it all is spread on so many sites and one has to spend a considerable part of his precious time to search it. In this regard ...

484

MRT versus CT in the diagnosis of pneumonia. Evaluation of a T_2-weighted utrafast turbo-spin-echo sequence (UTSE)  

International Nuclear Information System (INIS)

Purpose: To evaluate a T_2-weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T_2-weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR_e_f_f/T_E/Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis and representation of the lesions, in 25% MRT was superior. MRT was better for the detection of pulmonary abscesses. In 93% the ...

1999-05-01

485

Fusion of information from optical, thermal, multispectral imagery and geologic/topographic products to detect underground detonations (video). Audio-Visual (Final)  

Energy Technology Data Exchange (ETDEWEB)

The video documents the results of a Small Business Innovative Research (SBIR-Phase II) project conducted for DARPA focusing on the use of all-source overhead remote sensor imagery for monitoring underground nuclear tests and related activities. The documentation includes: (1) the main unclassified body of the report; (2) a separate ground truth Annex; and (3) a separate classified Annex. Autometric's approach was to investigate the exploitation potential of the various sensors, especially the fusion of products from them in combination with each other and other available collateral data. This approach featured empirical analyses of multisensor/multispectral imagery and collateral data collected before, during, and after an actual underground nuclear test (named 'BEXAR'). Advanced softcopy digital image processing and hardcopy image interpretation techniques were investigated for the research. These included multispectral (Landsat, SPOT), ...

1992-04-01

486

Experiment for 3-component S-wave reflection survey. Part 3; Sanseibun S ha hanshaho no kiso jikken. 3  

Energy Technology Data Exchange (ETDEWEB)

Anisotropy has been investigated using S-wave as a technique for detecting fractures. In this study, fundamental experiments were carried out with slightly changing the measuring conditions at a place where anisotropy was expected. This paper describes the fundamental data acquisition of anisotropy analysis using S-wave, and a part of the results. The experiments were conducted on the agricultural road in Yamadera district, Matsuyama-machi, Yamagata Prefecture. Two flat unpaved roads meeting at right angles were used as traverse lines. In this place, several reflection surfaces were certainly detected by P-wave, and anisotropy of S-wave was confirmed from the velocity of refracted wave of S-wave. Data were processed for individual traverse lines meeting at right angles. Firstly, signal sweeping, correlation, and vertical superposition were made. Six kinds of data were prepared, i.e., three-component receiving records of ...

1996-10-01

487

Eddy currents signal processing for steam generator inspection in PWR nuclear power plants; Traitement des signaux de courants de Foucault pour le controle des tubes de generateurs de vapeur dans les centrales nucleaires REP  

Energy Technology Data Exchange (ETDEWEB)

Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostics system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of these items.

1991-07-01

488

Eddy currents signal processing for steam generator inspection in PWR nuclear power plants. Traitement des signaux courants de Foucault pour le controle des tubes de generateurs de vapeur dans les centrales nucleaires REP  

Energy Technology Data Exchange (ETDEWEB)

Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostic system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of these items.

1992-01-01

489

Determination of low level sulfides in environmental waters by automated gas dialysis/methylene blue colorimetry  

Energy Technology Data Exchange (ETDEWEB)

A sensitive and rapid automated method has been developed for the selective analysis of acid extractable sulfide in environmental samples by combining gas dialysis separation techniques with methylene blue detection procedures. Acid extractable sulfide is separated from the sample matrix by the gas dialysis membrane and subsequently trapped in a dilute sodium hydroxide receiving stream. This stream is reacted with N,N-dimethyl-p-phenylenediamine and ferric chloride to produce methylene blue which is then quantitated colorimetrically at 660 nm. For standards and nonturbid environmental samples, there is good agreement between the results obtained by this procedure and the standard methylene blue method. The effect of interferences on the accurate determination of sulfide by both methods was also examined and it was found that cupric ions significantly interfered with sulfide estimation. To obtain adequate sulfide recoveries in tap water and ...

1990-01-01

490

Detection of constitutive heterodimerization of the integrin Mac-1 subunits by fluorescence resonance energy transfer in living cells  

International Nuclear Information System (INIS)

Macrophage differentiation antigen associated with complement three receptor function (Mac-1) belongs to #beta#_2 subfamily of integrins that mediate important cell-cell and cell-extracellular matrix interactions. Biochemical studies have indicated that Mac-1 is a constitutive heterodimer in vitro. Here, we detected the heterodimerization of Mac-1 subunits in living cells by means of two fluorescence resonance energy transfer (FRET) techniques (fluorescence microscopy and fluorescence spectroscopy) and our results demonstrated that there is constitutive heterodimerization of the Mac-1 subunits and this constitutive heterodimerization of the Mac-1 subunits is cell-type independent. Through FRET imaging, we found that heterodimers of Mac-1 mainly localized in plasma membrane, perinuclear, and Golgi area in living cells. Furthermore, through analysis of the estimated physical distances between cyan fluorescent protein (CFP) and yellow fluorescent ...

2006-08-04

491

Thermal performance of automotive aluminium plate radiator  

Energy Technology Data Exchange (ETDEWEB)

The thermal performance of an automotive radiator plays an important role in the performance of an automobile's cooling system and all other associated systems. For a number of years, this component has been given little attention with very little changing in its manufacturing cost, operation and geometry. As opposed to the old tubular heat exchanger configurations used in automotive radiators, plate heat exchangers currently form the backbone of today's process industry with their advanced performance reaching levels the designers of tubular heat exchangers can only dream of. The aluminium roll-bonding technique widely used in manufacturing the cooling compartments for domestic refrigeration units is one of the cheapest methods for heat exchanger manufacturing. Using this technique, it is possible to manufacture a wide range of heat exchanger configurations that can help augment heat ...

2005-06-01

492

Radiosurgery for metastatic brain tumors  

International Nuclear Information System (INIS)

Stereotactic radiosurgery (SRS) precisely delivers high-dose radiation to a small target (usually less than 3-4 cm in diameter), in a single session with steep dose-fall, employing various radiation methods. SRS provides good tumor control for small brain metastases from various primary cancers, with minimal untoward effects on surrounding normal brain. This excellent tumor control prevents neurological death and maintains good activity of daily life. Although surgery with whole-brain radiation therapy (WBRT) remains an important option for patients with a solitary brain metastasis, SRS with or without WBRT should be considered in patients with a limited number of small tumors and a good prognosis. Many reports, as well as both retrospective and prospective reviews, have shown WBRT before or after SRS to improve local control and reduce new distant lesion emergence. However, upfront WBRT does not improve survival. There are ...

2009-08-01

493

Multislice spiral CT (MSCT) in pediatric radiology: dose reduction for chest and abdomen examinations  

International Nuclear Information System (INIS)

The advent of multislice spiral CT (MSCT) technique has led to new aspects of dose reduction, especially for the dedicated use of MSCT in children. Optimizing pediatric MSCT protocols according to the clinical problem allows reduction of radiation exposure to a minimum without loss of diagnostic quality. The different parameters that influence the degree of dose reduction, like tube current-time product (mAs), tube voltage (kV), collimation and pitch, are discussed in context with previously published data and our own experience in nearly 200 pediatric CT examinations. In our department, the effective mAs is calculated for a pediatric chest MSCT by multiplication of the body weight in kilogram with a factor of 1 to 1.5 and for a pediatric abdominal MSCT by multiplication with a factor of 2 to 2.5. To calculate the equivalent effective dose for a contrast media-enhanced 80 kV protocol, the effective mAs of the 120 kV protocol can be multiplied ...

2004-07-01

494

Joining of zirconium alloys  

International Nuclear Information System (INIS)

Alloys of zirconium are widely used in various core components of power reactors. Nuclear assemblies require high degree of reliability and integrity for performing in radiation and corrosive atmosphere. The hostile environments of reactor core and inaccessibility for repairs make it mandatory to select only those joining techniques which produce not only superior quality but are also amenable to NDT methods and such other techniques which ensure acceptable performance. The author has worked on various types of welding of zirconium alloys for different applications. Modern techniques in electron beam (EB) welding, resistance welding, GTAW welding and laser welding have been developed for joining Zr alloys components for different types of reactors. Many of these have been standardized and successfully used in production. Several advancements have been made in the welding technologies towards achieving ...

2002-09-11

495

Development of food preservation and processing techniques by radiation  

International Nuclear Information System (INIS)

Development of food preservation and processing techniques by radiation was performed. Gamma irradiation at 2-10 kGy is considered to be an effective method to control pathogenic bacteria in species including Escherichia coli O157:H7. Gamma irradiation at 5 kGy completely eliminated pathogenic bacteria in beef. Gamma irradiation at such doses and subsequent storage at less than 4 deg C could ensure hygienic quality and prolong the microbiological shelf-life resulting from the reduction of spoilage microorganisms. Gamma irradiation on pre-rigor beef shortens the aging-period, improves tenderness and enhances the beef quality. And, a new beef processing method using gamma irradiation, such as in the low salt sausage and hygienic beef patty was developed. Safety tests of gamma-irradiated meats(beefs: 0-5 kGy; porks: 0-30 kGy) in areas such as genotoxicity, acute toxicity, four-week oral toxicity, rat hepato carcinogenesis and the anti oxidative ...

1988-04-18

496

Use of primary electron counting for detection of ultrasoft x-rays with a low-pressure multistep gaseous detector  

International Nuclear Information System (INIS)

The use of primary electron counting techniques as an alternative to the more usual parallel plate avalanche chamber that has been employed in soft x-ray scattering experiments is being investigated at the National Synchrotron Light Source. The theoretical aspects of primary electron counting and motivation behind building a primary electron counting detector are described, as well as characteristics and future improvements of the device constructed at the NSLS. The detector consists of a low electric field drift region and a low pressure multistep avalanche region which can be operated with two or three stages of electron multiplication. The device has worked well in extensive tests as a simple parallel plate avalanche chamber, providing energy resolutions of 58% and 43% at 277 and 500 eV, respectively. Operated as a primary electron counter, preliminary results show an energy resolution of 38% at 500 eV.

497

Brine injection studies at Lawrence Berkeley Laboratory  

Energy Technology Data Exchange (ETDEWEB)

As an integral part of DOE/GTD's Brine Injection Program, LBL is developing and demonstrating methods for: (1) designing and analyzing injection tests, (2) predicting and monitoring migration of injected fluids, and (3) optimizing field-wide injection and heat extraction operations in geothermal reservoirs. Computational and well test techniques are being developed (a) to detect and predict the movement of fluids of contrasting temperatures, phase compositions and chemistries in the injected formation, and (b) to characterize the associated physical and chemical processes occurring in the reservoir. LBL's theoretical and field-related brine injection activities in FY 1986 are described, and progress made during FY 1987 is discussed.

1987-01-01

498

Asymptotic Analysis of Double-Scattering Channels  

CERN Document Server

We consider a multiple-input multiple-output (MIMO) multiple access channel (MAC), where the channel between each transmitter and the receiver is modeled by the doubly-scattering channel model. Based on novel techniques from random matrix theory, we derive deterministic approximations of the mutual information, the signal-to-noise-plus-interference-ratio (SINR) at the output of the minimum-mean-square-error (MMSE) detector and the sum-rate with MMSE detection which are almost surely tight in the large system limit. Moreover, we derive the asymptotically optimal transmit covariance matrices. Our simulation results show that the asymptotic analysis provides very close approximations for realistic system dimensions.

2011-01-01