The influence of scattered radiation on recording systems and quality-assurance test parameters
International Nuclear Information System (INIS)
Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).
1988-02-23
The influence of scattered radiation on recording systems and quality-assurance test parameters
International Nuclear Information System (INIS)
Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).
Radiological equipment for emergencies
Energy Technology Data Exchange (ETDEWEB)
A brief guide to training and equipment needed to effectively manage victims of radiation accidents. (DT)
1985-01-01
Radiation Isotope Identification Device (RIIDs) Field Test and Evaluation Campaign
Energy Technology Data Exchange (ETDEWEB)
Handheld, backpack, and mobile sensors are elements of the Global Nuclear Detection System for the interdiction and control of illicit radiological and nuclear materials. They are used by the U.S. Department of Homeland Security (DHS) and other government agencies and organizations in various roles for border protection, law enforcement, and nonproliferation monitoring. In order to systematically document the operational performance of the common commercial off-the-shelf portable radiation detection systems, the DHS Domestic Nuclear Detection Office conducted a test and evaluation campaign conducted at the Nevada Test Site from January 18 to February 27, 2006. Named 'Anole', it was the first test of its kind in terms of technical design and test complexities. The Anole test results offer users information for selecting appropriate mission-specific portable ...
2007-08-01
International Nuclear Information System (INIS)
Many mechanical parts are subjected to stresses and strains that may eventually lead to their failure. In order to prevent the costly delays associated with equipment down-time, many parts have to be tested for weaknesses and defects when machinery is constructed or dismantled for maintenance. These procedures are known as Non-Destructive Testing (NDT) methods. Five types of non-destructive testing methods routinely used are radiographic testing, ultrasonic testing, magnetic particle inspection, liquid penetrant testing and eddy current testing. Out of these five techniques industrial radiography plays an important role in non-destructive testing to reveal interior defects in materials. In radiography almost two-thirds of the radiation reaching the film is scattered radiation which does not form the image of defects. Scattered radiation generated inside and outside a material has a very large effect on ...
1998-02-01
Programmable radionuclide X-ray fluorescence multi-channel spectrometric analyzer, type 123-1
International Nuclear Information System (INIS)
The whole equipment consists of three separate portable parts: a detector case, a microprocessor and a graphic TV monitor. Magnetic tape memory and an x-y recorder can be connected for recording the measured spectra. The analyzer contains two built-in exchangeable excitation radionuclides. Fluorescence and scattered radiation is detected using a proportional detector. The detected pulses are analyzed by a 256-channel analyzer and the results are shown on the display. The device may be used in mining laboratories, coal and ore dressing plant control rooms or in mining fields of open cast mines for quick detection of the quality of mined or dressed raw materials. (E.S.). 1 fig.
1988-01-01
This investigation describes the technique for the detection of the X-ray fluorescent radiation
1972-01-01
Granite Countertops and Radiation | Radiation Protection | US EPA
... Top of page Testing Radiation coming from granite countertops results from natural radioactive material in the granite. Identifying the presence and concentration of radioactive elements in granite requires expensive and sophisticated portable instruments or laboratory equipment. These instruments and equipment require proper calibration, and interpretation of ...
Equipment hardening and hardness assurance
International Nuclear Information System (INIS)
The introduction of tolerance to radiation (''radiation-hardness'') into large electronic systems is one of the major tasks to which this Handbook will be put. The practices recommended here for inculcating radiation-tolerance in equipment require advanced physical modeling techniques, precise engineering procedures, and firm assurance procedures. The degree to which these procedures should be used in an equipment project can be measured by the severity of the raw radiation environment, the desired reliability of the system, and the requirement of that project for radiation-sensitive technologies. The balance of device/circuit design versus shielding will depend on whether the radiation is highly penetrating -- as in isotope handling or military environments -- or readily attenuated, as in space. In this chapter the ...
Fitness of equipment used for medical exposure to ionising radiation
Energy Technology Data Exchange (ETDEWEB)
The purpose of this note is to provide guidance to those who have duties under the Health and Safety at Work Act and other relevant legislation. It gives guidance on the practical application of legislation, concerning radiotherapy equipment. Two particular issues arise out of the requirements of Regulation 33 of the Ionising Radiations Regulations 1985 (IRR85) in relation to equipment which is used for medical exposures. These are the requirement to select, install and maintain this type of equipment in such a way that it is capable of restricting, so far as reasonably practicable, the medical exposure of any person where this is compatible with the intended clinical purpose, including the need to ensure that equipment used for radiotherapy is properly calibrated, and the requirement to notify the Health and Safety Executive (HSE) when an incident occurs involving a malfunction or ...
1992-05-01
Instruments for X-ray fluorescence analysis and spectrometry
International Nuclear Information System (INIS)
The radionuclide X-ray fluorescence analyzer consists of a source changer and a sample changer. "5"5Fe, "1"0"9Cd and "2"4"1Am are used as excitation sources. The radiation is detected with a semiconductor Si(Li) detector. The complete assembly of the apparatus consists of an imagine unit, a keyboard, a floppy disc drive, a printer, a console and a rack with analog and digital electronics. Its multichannel amplitude analyzer consists of power supplies, a high voltage supply, a linear amplifier, an analog-to-digital converter and a computer. The technical specifications are given. The control and data processing system is controlled with an MHB 8080A microprocessor. Software for semiconductor gamma spectrometry and for quantitative gamma spectrometry will be supplied with the equipment. (E.S.). 3 figs., 4 refs.
A mobile gamma scanning system for detecting radiation anomalies
Energy Technology Data Exchange (ETDEWEB)
A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A /sup 226/Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.
1983-09-01
A mobile gamma scanning system for detecting radiation anomalies
International Nuclear Information System (INIS)
A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A "2"2"6Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.
International Nuclear Information System (INIS)
Remote-controlled handling systems are required for work to be done in the decommissioning and dismantling of nuclear facilities. These systems are equipped with electronic devices suitable for use in working environments affected by ionizing radiation. The publication explains the step-wise progress achieved for improving the radiation resistance of electronic devices with the example of a four-quadrant controlling device for the motors of a manipulator. The radiation resistance of the device could be enhanced to radiation energies of 5.500 Gy. This means that a manipulator vehicle equipped with this controlling device can take up to approx. 15 kGy all in all, taking into account its own shielding properties. (DG).
Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden
Energy Technology Data Exchange (ETDEWEB)
The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. ...
2007-11-15
x - NASA Technical Reports Server
Mar 1, 2011 ... Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation ...
Multi-spectral schottky barrier infrared radiation detection array
Energy Technology Data Exchange (ETDEWEB)
A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.
1983-12-27
Multi-spectral schottky barrier infrared radiation detection array
International Nuclear Information System (INIS)
A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.
Radiation-protection survey guide: fixed radiographic unit. Final report, June 1980-April 1985
Energy Technology Data Exchange (ETDEWEB)
Prior to routine use, all newly installed x-ray machines must have a radiation-protection survey by a qualified expert. The survey is an evaluation of existing or potential radiation hazards associated with the use of diagnostic x-ray equipment under specific conditions. Such evaluation includes the measurement of exposure levels in the environment as well as environmental levels arising from operation of the equipment. The survey also includes an evaluation of the safety characteristics of the x-ray unit.
1985-05-01
Infrared radiation features of coal and rocks under loading
Energy Technology Data Exchange (ETDEWEB)
Samples of fat coal-E, its roof sandstone-A and blind coal-W from two coal mines in Hebei Province of China were brought to the laboratory to study the features of infrared thermal images and radiation temperature in the course of uni-axial load and uni-axial cycle load. To check the results of infrared remote sensing detection, two other methods, acoustic emission detection and electrical resistance detection were also used. The AGA-782 thermalvision detected change of the temperature field of the samples` surfaces. The study showed that: (1) coal rocks and sandstone in the course of loading have three types of infrared thermal image features and three types of infrared radiation temperature features; (2) infrared detection is comparable with acoustic emission detection and electrical resistance ...
1998-10-01
Standard radiation monitoring at Sendai nuclear power station
International Nuclear Information System (INIS)
Standard radiation monitoring has been conducted at Sendai nuclear power station for the purpose of estimation of 'source activity' during refueling outage and evaluation of countermeasures to reduce dose rate. Selected objects of the monitoring are radiation dose rate at maintenance area, radiation field at each equipment and piping, coolant chemistry and plant operation condition. Monitored data indicates that 'source activity' variation can be estimated to some extent using influential factors, and that evaluation of change of loose crud activity, which is presumed to be represented by the dose rate at letdown heat exchanger, is necessary to further explain change in radiation field at main work area. (author).
Energy Technology Data Exchange (ETDEWEB)
The document, based on European guidelines, was jointly developed by radiation oncologists, radiation physicists and radiation technologists. It contains the aims of the guidelines, professional profiles, roles and responsibilities, personnel and equipment requirements, procedures.
1996-12-01
Laser Technology for Remote Treatment of Atomic Equipment
International Science & Technology Center (ISTC)
Investigation of Interaction of Laser Radiation with Radioactive Deposits on the metal Surface and Creation of Experimental Stand for Development of Laser Technology for Remote Treatment of Materials Contaminated with Radioactive Substances at the Atomic Power Plants
IAEA Co-ordinated Research Program (CRP)
International Nuclear Information System (INIS)
The Coordinated Research Project is a topical collection of research agreements and contracts. The research contracts are awarded with financial support of about 10-20% of the total contract cost. Among the activities of the project is the organization of consultant group meetings and workshops involving several international experts and representatives of users and developers of border radiation monitoring equipment. The project also supports in coordinating the development of equipment and techniques for up-to-date border monitoring and in establishing of a process for providing nuclear forensics support to member states
2010-05-19
Electron linear accelerators for radiotherapy
International Nuclear Information System (INIS)
Present-day requirements for radiotherapy equipment are considered. The recently developed linacs of LUE-5, LUE-25, LUE-15MM models, as well as a newly designed unified series of medical linacs of LUER-5M, LUER-20M, LUER-40M models are described in brief. The main scientific and technical problems that were solved during their construction, namely, development of accelerating structures, a radiation head, dosimetry equipment, a programming unit, a magnetic mirror etc. are described.
1983-06-01
International Nuclear Information System (INIS)
The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous ...
2008-05-01
International Nuclear Information System (INIS)
... 3-89701-147-6 0949-2224 245 p. animal cells dna genetic radiation effects
1998-03-01
Energy Technology Data Exchange (ETDEWEB)
Disclosed herein is a radiation detector providing for the in situ automatic sampling of fluids containing substances emitting radiation, especially Cerenkov radiation. The detector permits sampling within well casings and is self-purging such that no additional provisions must be established for the storage and disposal of contaminated fluids.
1993-01-01
Energy Technology Data Exchange (ETDEWEB)
In this work a study of simulation of the gamma graphic studies that are carried out in human esophagus in the Dept. of Nuclear Medicine of the 'Celestino Hernandez Robau Hospital of Santa Clara is presented. For the investigation tubular reactors were used and sting-response techniques with radioactive tracer of Technetium 99 metastable to a concentration of 1 mCi and several flows were applied. The distribution curves of residences times were obtained, those that respond to an equation of the type: Y = A + B exp (- exp((x-C)/D)) - ((x-C/D)+1). They were also carried out, optimizations studies of the doses of the radioactive to give to the patients from 1 mCi (that is the one used in studies) up to 0,5 mCi, and the influences on the obtained distributions of residence time were analyzed. It was confirmed the possibility to lower the doses with clear information of the signal. It was also carried out a simulation of the attenuation of the radiations that ...
2003-07-01
Interim explosives detection alternatives
Energy Technology Data Exchange (ETDEWEB)
There is a general concern with insiders smuggling bomb quantities of explosives into sensitive facilities such as nuclear facilities. At this time, there is no single explosives detection device that is suitable for monitoring personnel and their packages for explosives in an operational facility environment. However, there are techniques combining available commercial technologies with procedures and threat analysis that can significantly increase the insiders risk and reduce the population of adversaries. This paper describes the available applicable explosives detection technologies and discusses the techniques that could be implemented on an interim basis. It is important that these techniques be considered, so that some interim level of security against the explosives threat can be established until more sophisticated equipment that is under development becomes available.
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
It may be necessary to reduce microbiological contamination of crude drugs (medicinal plants or their parts like roots, leaves, flowers). This can be done by treating the drugs with ionizing radiation. Meethods for detection of such an irradiation were developed. It could be pointed out that measurements of luminescence, viscosity and electron spin resonance were suitable for specific drugs, but not for all drugs. (orig.).
1992-09-01
Detection of Free-Living Amoebae in Some Water Sources and its Control by Ultraviolet- Radiation
International Nuclear Information System (INIS)
Among the numerous free-living amoebae (FLA) of soil and water habitats, certain species belonging to two genera Acanthamoeba and Naegleria are facultative parasites of man.They cause disease called primary amoebic meningoencephalitis where history of contact with water was recorded in most of the cases especially with Naegleria species. The present work aimed to search for presence of free-living amoebae in the water and trials for its control by Ultraviolet-radiation (UV-radiation). Samples from different water sources were examined for the presence of free-living amoebae. These samples were cultured on non-nutrient agar streaked with bacteria. Amoebae were detected and identified by means of their morphological characters. Twelve positive cases of one hundred and twenty examined samples could be detected. The positive samples were exposed to different doses of UV-radiation for ...
Energy Technology Data Exchange (ETDEWEB)
The neutron detector is cased in a metal envelop and has one detector with a very sensitive fission chamber and a second detector with a fission chamber less sensitive that the first one and a boron coated ionisation chamber for reducing gamma radiation detection.
1992-06-12
Indirect Dark Matter Detection with Cosmic Antimatter
The indirect detection of particle dark matter (DM) is based on the search for anomalous components in cosmic rays (CRs) due to the annihilation of DM pairs in the galactic halo, on the top of the standard astrophysical production. These additional exotic components are potentially detectable at Earth as spectral distortions for the various cosmic radiations: $\\chi + \\chi \\to q \\bar{q}, W^+ W^-, ... \\to \\bar{p}, \\bar{D}, e^+ \\gamma and \
2010-01-01
Investigation of radiation effects of interaction of #beta#"- -radiation with polyvinylchloride
International Nuclear Information System (INIS)
Dissipation of energy of #beta#"--radiation in polyvinylchloride (PVC) was analyzed. Change of PVC properties at irradiation by beta beams with energy 2,32 MeV was characterized using potentials of inter- and intramolecular interactions as well as Born potential. Correlation between some micro- and macroproperties of PVC was detected and ways of their controlled correction were proposed. (authors)
Circumsolar radiation telescope
Energy Technology Data Exchange (ETDEWEB)
A circumsolar telescope for determining the flux of energy from the sun and from the circumsolar region as a function of angle, wavelength, and atmospheric conditions is presented. The telescope system consists of a specially designed scanning telescope, an electronic control and recording system and some auxiliary equipment. The detector is a pyroelectric crystal, a type of thermal detector, thus the fundamental measurement is relatively wavelength insensitive. The telescope is designed to provide data for all weather conditions during which a concentrating solar energy system would be operating. Analyses show that for a clear blue sky, the amount of radiation coming directly from the sun, while for a sky with thin clouds or haze, the circumsolar radiation is some 25% of the direct solar radiation. Under such conditions a measure of the circumsolar radiation is necessary for an ...
1980-01-01
''SEPIO NUANCE DT'' digital mammography system
International Nuclear Information System (INIS)
In the past, the need for high quality images, i.e., very sharp and clear images, in mammography have prevented mammography equipment from being digitalized; however, recent advances in detection technology such as development of a high resolution digital X-ray detector have produced improvements in digital mammography. Digital mammography is expected to replace conventional film-screen mammography. We have developed a digital mammography system, named ''SEPIO NUANCE DT'', which is equipped with a direct conversion flat panel detector. The present paper describes the high basic performance and user-friendly functions of the system. (author)
2007-03-01
International Nuclear Information System (INIS)
To respond to an increase of social problems concerning orphan sources in Japan, a working group was formed in the Japan Health Physics Society. In this working group, we investigated how to prevent acute radiation hazard or social panic regarding orphan sources in scrap metal and detection system for orphan sources brought into scrap yards before recycle. For detection system in a scrap yard we conducted an experiment on detectability of monitoring instrument using a radiation source mixed in scrap metal on a truck. The result showed that it was not easy to detect even a high-level source if it was shielded by scrap metal. We also estimated detection limits for radioactive materials in scrap metal by calculation that was validated with experimental data. We summarized present status about orphan sources in Japan and proposed a ...
2002-10-20
Energy Technology Data Exchange (ETDEWEB)
A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the detector as rays parallel to the detector axis of the detector. The collimator may be a ...
2003-03-04
International Nuclear Information System (INIS)
The main problems arising in decommissioning nuclear-powered submarines (NPS) relate to choosing a concept of handling reactor compartments followed by handling technology development. Reactor compartments (RC) are characterized with extremely space-saving or integral layout of large-size power equipment and systems, restricted access for dismantling, high radiation dose rates in a number of bays of RC. The above RC features pose a problem to find optimum option of RC utilization which on the one hand would be the most cost efficient, and the safest as possible on the other, i.e. dose commitments of personnel involved should be minimum, and effect on population and environment should be negligible. The main radiation factors specifying safety in RC handling at any decommissioning stage are as follows: (1) total radioactivity integrated in reactor facility (RF); (2) distribution of this radioactivity through RF ...
1996-03-10
A Radiation Laboratory Curriculum Development at Western Kentucky University
We present the latest developments for the radiation laboratory curriculum at the Department of Physics and Astronomy of Western Kentucky University. During the last decade, the Applied Physics Institute (API) at WKU accumulated various equipment for radiation experimentation. This includes various neutron sources (computer controlled d-t and d-d neutron generators, and isotopic 252 Cf and PuBe sources), the set of gamma sources with various intensities, gamma detectors with various energy resolutions (NaI, BGO, GSO, LaBr and HPGe) and the 2.5-MeV Van de Graaff particle accelerator. XRF and XRD apparatuses are also available for students and members at the API. This equipment is currently used in numerous scientific and teaching activities. Members of the API also developed a set of laboratory activities for undergraduate students taking classes from the physics curriculum (Nuclear Physics, Atomic ...
2009-03-10
International Nuclear Information System (INIS)
Liquid radioactive waste treatment method of using evaporator was widely used from Kori 1 to Uljin 3 and 4, but a liquid radioactive waste treatment equipment that uses an ion exchange method instead of an evaporator was adopted aiming to minimize amount of radioactive waste and radiation exposure. However, the same equipment was introduced and applied for the first time in Korea and had experienced difficulties in securing credibility for the equipment and handling of liquid radioactive waste with inadequate data about performance and experience in operation and maintenance. In this study, examination, application and effect analysis was performed on the optimization measure for handling liquid radioactive waste of Yonggwang Nuclear Power Unit 5 and 6(YGN 5 and 6) that applies an ion exchange method
2010-10-01
Electromagnetic fields - introduction to relevant issues
International Nuclear Information System (INIS)
This introductory paper surveys potential sources of electric magnetic, and electro-magnetic fields. Various cases are discussed to exemplify the total frequency range: nuclear magnetic resonance tomography, high-voltage transmission lines, transformer stations, effect lighting balls, military transmitters, transmitter towers of the Postal Services and other operators, mobile radiotelephone equipment, large broadcasting transmitters, radar radiation, high-frequency heat therapy. There is evidence suggesting that electric, magnetic and electro-magnetic fields may possibly represent a certain nuisance or health hazard even at field strength occuring in equipment used for every-day-life purposes, with an emphasis on their possible actions and effects in children and adolescents. The author discusses, in conclusion, the aerial equipment ordinance issued by Lower Saxony. (Uhe).
1993-06-01
Gravitational waves from the big bang
Energy Technology Data Exchange (ETDEWEB)
The gravitational radiation produced by the big bang is calculated in order to provide a condition for the unification of the gravitational and electromagnetic forces. By analogy with electromagnetic radiation and under the assumption that gravity is also quantized, it is shown that matter would have decoupled from gravitational radiation at a time of approximately 10 to the -43rd sec and would have dominated it at 10 to the -17th sec. Furthermore, the theory predicts a background gravitational radiation temperature of 0.003 K which peaks at a wavelength of about 1 m, which may be detected by the comparison of the synchronization of clocks at increasing distances.
1980-12-20
Radon in soil gas survey in Curitiba (Brazil)
International Nuclear Information System (INIS)
This work describes the radon in soil gas measurements performed during the last two years in cooperation between the Laboratory of Applied Nuclear Physics of the Federal University of Technology (UTFPR), the Nuclear Technology Development Center (CDTN) and the Institute of Radiation Protection and Dosimetry (IRD) from the Brazilian Nuclear Energy Commission (CNEN). Following previously concluded measurements of radon concentration in dwellings and the measurements of 222Rn activity in drinking water collected at artesian bores of Curitiba urban area, present step of activities has been dedicated to measurements of radon concentration in soil gas. Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specially developed for such measurements Soil Gas Probe through the air pump and filter system. After the Probe was inserted, the ground has been tamped down around the probe, to prevent air from moving vertically along the outside ...
2002-10-08
Radiation protection of the personnel who will perform interventions in the LHC Beam Cleaning Insertions is mandatory and includes the design of equipment and the establishment of work procedures. Residual dose rates due to activated equipment are expected to reach significant values such that any maintenance has to be planned and optimized in advance. Three-dimensional maps of dose equivalent rates at different cooling times after operation of the LHC have been calculated with FLUKA. The simulations are based on an explicit calculation of induced radioactivity and of the transport of the radiation from the radioactive decay. The paper summarizes the results for the Beam Cleaning Insertions and discusses the estimation of individual and collective doses received by personnel during critical interventions, such as the exchange of a collimator or the installation of Phase 2. The given examples outline the ...
2005-01-01
Identification of oxidation states of ultra-trace elements by radiation detection
International Nuclear Information System (INIS)
The determination of the oxidation state of ultra-trace elements in the environment, especially in the case of actinides, is of importance in many ways. Speciation techniques using radiation may comprise methods based on the detection of the nuclear and atomic radiations emitted in radioactive decay or methods using external sources of excitation. In the former instance, information can be obtained from the energy and intensity of radiation, but at present the partition method is still the most commonly used, although its reliability is questionable. Excitation with intense laser beams, as is currently being used for trace element analysis in photoacoustic and thermal lensing spectroscopic techniques, could conceivably be applied under suitable conditions to ultra-trace elements with a sensitivity approaching that of the radiochemical methods.
1989-11-01
Leak detection on petroleum pipelines
Energy Technology Data Exchange (ETDEWEB)
This paper presents a unique method, currently under evaluation, that can continuously track pipeline operation providing essentially instantaneous responses to leaks or ruptures without causing a pressure drop or energy loss. Using the highly linear characteristics of a very accurate and repeatable meter and then correlating it to a second identical unit, a dynamic leak detection system is planned that can be retrofitted on existing pipelines without a major construction effort nor destroying the integrity of the existing transmission line. Initial tests performed on a crude oil transmission line verified the equipment's performance and established that the repeatability limits are sufficient to continue development of the concept.
1984-04-01
The importance and unique aspects of radiation protection in medicine
British Library Electronic Table of Contents (United Kingdom)
Radiation protection in medicine has unique aspects and is an essential element of medical practice. Medical uses of radiation occur throughout the world, from large cities to rural clinics. It has been estimated that the number of medical procedures using radiation grew from about 1.7 billion in 1980 to almost 4 billion in 2007. In spite of these large numbers, there are many parts of the world without adequate equipment, where the ability to perform additional medical procedures would likely result in a net benefit. Medicine accounts for more than 99.9% of the per caput effective dose from man-made sources. The goal in medical exposure is not to give the lowest dose, but to provide the correct dose to enable the practitioner to make the diagnosis or cure a tumour. Too little or too much ...
2010-01-01
The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous ...
2008-05-01
Proceedings, international symposium on mine mechanization and automation
Energy Technology Data Exchange (ETDEWEB)
Papers are presented under the session headings: research in mechanical fragmentation; rock characterization, remote sensing and interface detection; monitoring, data transmission and communications; tunnel boring machines; minewide monitoring and expert systems for ground control; machine guidance; shaft and raise boring; automation of drilling equipment; machine automation and control; new developments in mechanical miners; materials handling; innovative mining systems; general minewide monitoring and expert systems; ground support; human factors; and extraterrestrial mining.
1991-01-01
Natural radioactive materials occurrence in oil facilities
International Nuclear Information System (INIS)
This work presents and describes the natural radioactive occurrence in oil facilities. The origins of the detected radioactivity and the reasons of its settlement are discussed. The measurements results carried out in oil facilities in the Neuquina basin (Argentine) are shown in this work. The aim is to describe the actual situation and to evaluate the magnitude of the problem. Finally, recommendations are proposed to protect the health of the workers, especially of those who carry out the cleaning of the equipment, and to guarantee an appropriate final disposal for the generated radioactive residuals. (author)
2001-06-01
Mammography: limits of a technique
International Nuclear Information System (INIS)
Breast cancer represents today more than 30% of all cancers and is responsible for about 20% of deaths due to cancer. The potentialities of mammography have increased in recent years through improvements in equipment and methodologies. In this paper the conventional mammography using film and image intensifiers is compared with digital mammography. Digital mammography presents clear advantages in storage and handling of information. Also its higher sensitivity will lead to an earlier detection of anomalies and a decrease in the number of invasive exams and surgeries
2001-05-01
ETB dosemeter, a passive integrating radon dosemeter combining activated charcoal and TLD
Energy Technology Data Exchange (ETDEWEB)
A passive integrating radon dosemeter is described. The radon dosemeter is based on radon adsorption on activated charcoal. By placing TLD crystals inside an open charcoal container, the beta radiation from radon daughters, produced by the decay of adsorbed radon, is detected continuously during the exposure time. After closing the container, radiation will still be detected by the TLD crystal. Calibration procedures are reported and the suitability of the dosemeter is discussed. The dosemeter proved to be suitable for measurements during periods from a few days to two weeks both in domestic and mine atmospheres.
1983-01-01
Technology development tendency and R and D idea of NPP radiation monitoring system
International Nuclear Information System (INIS)
This paper gives a general description of functions, usages and system configurations of the instruments and their major units or components of the radiation monitoring system, as well as the status and technical gap between domestic and foreign technologies. And then the paper also puts forward an idea on product R and D, i.e. combination of independent R and D and innovation, assimilation and re-innovation of foreign advanced technology at present situation in order to keep pace with the rapid development of nuclear power in China and achieve the goal of localization of nuclear power equipment. (authors)
2009-06-01
International Nuclear Information System (INIS)
Large-scale decommissioning of Russian nuclear-powered submarines (NPS) and their utilization prospects gave rise to numerous complicated scientific and technical, as well as economic, problems. Problems of handling of radioactive equipment from the reactor compartments (RC) are among the vital ones, arousing a growing concern with the public. Without solution of the problems the processes of NPS utilization can not be considered completed. It involves potential hazard, for the environment both from NPS being paid up (temporal on-float storage) with unloaded spent nuclear fuel (SNF), and RC, cut from submarine hull, containing highly radioactive equipment and materials but no SNF. Diverse variations of the concept of reactor compartment handling of NPS subject to, utilization are possible, but, in principle, there are essentially two variants: (1) RC utilization directly in the course of NPS utilization, envisaging removal of radioactive ...
1996-03-10
VGB guidelines on the consideration of noise emission in ordering power plant equipment
International Nuclear Information System (INIS)
The present guidelines supplement the 'VGB guidelines for the reduction of noise in thermal power plants' with indications for the ordering and quality assurance of the individual noise-producing machines and equipment of power plant operation. These guides are to simplify the commissioning and delivering for the orderer and deliverer. In addition, these guidelines are to lead to a successful cooperation of all parties in the reduction of the sound radiation. A precondition for this is an explanation of the sound technical demands which must be made on the single machines or mechanical equipment in power plant systems. A protection of the neighbourhood as well as operational personnel against noise according to the state of technology is to be achieved by a clear form of ordering and quality assurance. The ordering and assurance procedure for all aggregates in the region of the grounds of a power plant up to the ...
New concept to optimize emergency diagnoses in patients with multiple injuries
International Nuclear Information System (INIS)
To optimize the emergency care of patients with multiple injuries, a special emergency room with integrated radiological equipment has been developed. It consists of a linear array of a computed tomography system, a mobile C-arm with an integrated scattered radiation grid for conventional films and a C-arm fluorographic system. The intent is to avoid delay caused by transport and repositioning of the patient. It enables all necessary diagnostic procedures to be performed within a minimal amount of time. (orig./MG).
International Nuclear Information System (INIS)
Tarapur Atomic Power Station Unit-3 and 4 (TAPS -3 and 4) are the 540 MWe reactors. Unit-4 attained first criticality on 06th March 2005 and operated for about 230 effective full power days (EFPD). Unit-3 attained first criticality on 21st May 2006 and operated for about 20 EFPD. With the reactor operation radiation field increases on the Primary Heat Transport system equipments, Moderator system equipments and auxiliary system equipments due to deposition of fission products and activation products in different reactor systems. These dose rates significantly contributes to the external exposure and stations collective dose during reactor operation, refueling operation and maintenance activities. A study was undertaken at TAPS 3 and 4 to identify the system equipments showing the significant dose rates and identify the radionuclides present in the primary heat transport system, ...
2006-11-13
Scattered radiation effect on the defect image in high-energy bremsstrahlung introscopy
International Nuclear Information System (INIS)
Results of the evaluation of the scattered radiation effect on the image of defects in examined products are given. The formula is suggested which characterizes the image of defects on a scintillation screen as well as accumulation factors are calculated by the Monte-Carlo method. Values of fluctuations of absorbed energy in the screen used for the evaluation of sensitivity are experimentally obtained. The effect of high-energy bremsstrahlung on the defect detection is analyzed.
Energy Technology Data Exchange (ETDEWEB)
Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A /sup 241/Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer.
1984-10-01
International Nuclear Information System (INIS)
Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A "2"4"1Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer. (E.S.).
1984-01-01
International Nuclear Information System (INIS)
The book presents a very good account of all aspects of protection from ionizing radiation. The quantities and units are given and defined used in nuclear physics and dosimetry. The effects of ionizing radiation on cells and on man are described. The principles are presented of radiation protection including limits and valid regulations and decrees. Also discussed is internal irradiation and its modelling. A great part of the book is devoted to aspects of monitoring persons, the living and working environment and to the determination of internal contamination. The system of radiation protection in Czechoslovakia is described and some practical questions are discussed of protection during radiodiagnosis and radiotherapy, in the nuclear fuel cycle, in the operation of nuclear power installations and in crack detection. In conclusion a survey is given of the population exposure from ...
1988-01-01
ESR/Alanine dosimetry on Wolsung Unit 1
Energy Technology Data Exchange (ETDEWEB)
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement ...
2007-07-01
ESR/Alanine dosimetry on Wolsung Unit 1
International Nuclear Information System (INIS)
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement ...
2007-05-10
International Nuclear Information System (INIS)
The principle is described of a method using low-activity emitters as the primary radiation source for analysis. The selection of the radiation source and the detection methods including the assessment of the applicability of various radiation detectors are discussed. The benefits and the constraints of the method are considered. Practical examples are presented showing the application possibilities of the method for testing the thickness of bearing layers, piston ring coats, lead layers, etc. The possibility is shown of applying the rapid test for the composition of tungsten and chromium alloyed metal materials in testing complex systems. (J.K.).
1974-12-03
International Nuclear Information System (INIS)
An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).
1996-01-01
Air conditioning in high rise buildings; conditionnement d'air dans les immeubles de grande hauteur
Energy Technology Data Exchange (ETDEWEB)
This book brings together the 103 presentations given at the 2. conference of the international institute of refrigeration (IIF/IIR) about air conditioning in high rise office buildings. The main themes are: design of air conditioning equipment for high buildings; air quality and thermal comfort inside these buildings; constraints and possible improvements of the refrigeration equipment used; energy conservation; fire protection and smokes detection. All themes are presented both on the technical and economical points of view and concern more particularly the buildings of Chinese cities. This publication is available both on the book and CD-Rom forms. (J.S.)
2000-07-01
A study of neutron room scattering at RPCF
International Nuclear Information System (INIS)
High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National ...
1997-01-05
A study of neutron room scattering at RPCF
Energy Technology Data Exchange (ETDEWEB)
High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National ...
1996-09-01
Practical technological benefits of SRE decommissioning
Energy Technology Data Exchange (ETDEWEB)
The decommissioning of the Sodium Reactor Experiment is essentially complete. Contaminated materials, equipment, and soil were removed, decreasing the residual radioactivity to levels acceptable for future unrestricted use of the site. The fuel was removed and declad, tooling and techniques to support the decommissioning were developed, bulk sodium and residual sodium films were removed, coolant systems were dismantled, the reactor vessel was dissected, the interior surfaces of the facilities were decontaminated, and waste materials were packaged and shipped to burial sites. Radiation exposure to workers and the public was within the guidelines and as low as reasonably achievable. In performing the project, new decontamination techniques were tested, decontamination equipment was evaluated, and waste disposal methods were developed.
1982-01-01
Corrosion behavior of iron and nickel base alloys in high temperature and pressure water
International Nuclear Information System (INIS)
In equipment industries, the equipments handling industrial water and pure water are numerous. In power generation including nuclear power generation, water serves as a working medium. Review is made on the experiences in the corrosion of iron and nickel base alloys in high temperature, high pressure water and the results of researches derived from them. Under high temperature and high pressure, carbon steel, low alloy steel, stainless steel and high nickel alloy cause corrosion even in pure water. But in the case of serious corrosion, chlorine, oxygen, alkali and others in water take part. The following matters are described: corrosion by steam; stress corrosion cracking in pure water; corrosion by impurities in high temperature, high pressure pure water, i.e. chlorine ions, dissolved oxygen, and alkali; corrosion under radiation. (J.P.N.).
A brief history of the PUREX and UO{sub 3} facilities
Energy Technology Data Exchange (ETDEWEB)
The Plutonium-Uranium Extraction (PUREX) Plant, conceived during the early Cold War years, was a vehicle to increase significantly US nuclear weapons production capacity. The original PUREX Plant was a concrete rectangle 1,005 feet long and 61.5 feet wide. The shielding capacity of the concrete was designed so that personnel in non-regulated service areas would not receive radiation in excess of 0.1 millirem per hour. This report discusses the design of the PUREX Plant, the production chronology, projects and equipment changes, equipment decontamination and reuse, waste management, and contamination events that have occurred during the operation of the plant. Additionally, the development and history of the Uranium Trioxide Plant are also covered.
1993-11-01
Spontaneous radiation from relativistic electrons in a taper undulator. Technical report
The spectrum, angular distribution, polarization and coherence properties of the radiation emitted by relativistic electrons undulating through a quasiperiodic tapered magnetic field are studied. Tapering the wavelength and/or field strength along the undulator's axis has the effect of spreading the spectral line to higher frequencies; interference over this broader spectral range results in a more complex line shape. The angular dependence, on the other hand, is not affected by the amount of taper. The polarization of the radiation in the forward direction is determined by the transverse polarization of the undulator, but the polarization changes off axis. The radiation patterns predicted here are distinct from those of untapered undulators, and their detection is now feasible. They will provide useful diagnostics of electron trajectories and threshold behavior in free-electron-laser ...
1983-06-01
International Nuclear Information System (INIS)
There are many differences between industrial CT and industrial radiography, such as imaging principle, inspection time, radiation dose and the requirements for operators etc. The national standards for radiation protection of industrial detection are not applicable to the requirements of protection and safety for #gamma#-ray industrial CT to some extent now. In order to standardize the production and use for #gamma#-ray industrial CT, protect the safety of operators and the public, and to promote the popularization and application of #gamma#-ray industrial CT, it is significant to establish the national standards for radiation protection of #gamma#-ray industrial CT as soon as possible. The purpose of this paper is to introduce the contents of this standard, and specify some important terms. Then there is a brief discussion on the existing problems during establishing such standards. At last, the paper ...
2009-03-01
Energy Technology Data Exchange (ETDEWEB)
This study is part of a greater project from IPT (Sao Paulo's Institute of Technology), which foresaw an energetic use for elephant-grass (Pennisetum purpureum). Biomass gasification is an sustainable option for energy supply, which presents low pollutants emission rate and allows - through the global cycle of growing and consumption of feedstock (vegetables), a balance between consumption and production of carbonic gas, preventing an increase of the carbonic gas levels in the atmosphere. A gasifier was built with internal diameter of 400 mm and total height of 4600 mm . The equipment was tested for gasification of elephant-grass (Pennisetum purpureum) at a 100 kg/h rate. The equipment was tested and some constructive faults were detected. In the countryside, this biomass is commonly used for cattle feeding It was evaluated an adequate diesel-electric-generator. to work at hybrid regime, using 70% biomass gas and ...
2000-07-01
Sensors to detect CO based in SnO. Sensores para detectar CO basados en SnO
Energy Technology Data Exchange (ETDEWEB)
The development of solid state chemical sensors, and more specifically of gas sensors, is carried out with great strength in the present time since the environmental pollution and the security in work and domestic ambient are problems of great interest and social impact. The main fields of application, are: automobile, domestic sensors, control of industrial process, bio medicine, environment. These chemical sensors are experimenting a great advance because of the advantages they offer, as low cost, simple operation, possibility of measure continuous and ''In situ'' and small size, in contrast with analytical techniques that need complex instrumentation and large size equipments. In the present work, a sensor for CO detecting concentrations as low as 50 p.p.m., is studied showing great interest since this gas is highly toxic even to such a low concentration. (Author)
1993-01-01
International Nuclear Information System (INIS)
The 1993 Petroleum Hydrocarbons Conference was comprised of 3 days of technical presentations within the following topic areas: pollution prevention and cost control; development of remediation levels; free-phase and dissolved hydrocarbon contamination management; investigation and analysis of petroleum hydrocarbons; applications of computer modeling for remediation; design and implementation of bioventing; design and implementation of air sparging; soil vapor extraction as a remediation technique; and ground water remediation using natural bacteria. In addition, more than 100 leading companies in the ground water and petroleum industries participated in the Conference Exposition in which a variety of equipment and services for preventing, detecting and remediating ground water contaminated by petroleum hydrocarbons and other organic chemicals was showcased. Individual papers have been processed separately for inclusion in the appropriate data ...
1993-11-10
A cosmological "probability event horizon" and its observational implications
Suppose an astronomer is equipped with a device capable of detecting emissions -- whether they be electromagnetic, gravitational, or neutrino -- from transient sources distributed throughout the cosmos. Because of source rate density evolution and variation of cosmological volume elements, the sources first detected when the machine is switched on are likely to be ones in the high-redshift universe; as observation time increases, rarer, more local, events will be found. We characterize the observer's evolving record of events in terms of a "probability event horizon", converging on the observer from great distances at enormous speed, and illustrate it by simulating neutron star birth events distributed throughout the cosmos. As an initial application of the concept, we determine the approach of this horizon for gamma-ray bursts (GRBs) by fitting to redshift data. The event rates required to fit the model are consistent with ...
2005-01-01
This workshop covered the latest practical engineering and operational management applications and techniques that have been found to enhance operational costs, reliability, and flexibility, with topics such as establishing the optimal refrigeration design cycle and operating design points; utility management; manpower scheduling; plant control philosophy and automation; short and long term maintenance scheduling; refrigerant loss detection and control; system contamination; component reliability; and equipment technical performance issues.
2006-11-10
Gases in insulating oil - analysis of dissolved gases using a portable chromatograph
Energy Technology Data Exchange (ETDEWEB)
New technological advances make it possible to perform on site gas-in-oil analysis quickly and efficiently. Gas-in-oil analysis is crucial in assessing the status of oil-filled electrical equipment. The new technique is used for extracting and measuring gases dissolved in electrical insulating oil. On-site sampling requires the use of a specially designed 100 ml capacity syringe. Extraction of the dissolved gases is made with a precise ratio of oil to air. A comparison was made between the analysis of the on-site and the laboratory techniques. Results showed that the detection limits of the on-site technique were comparable to those obtained by laboratory methods.
1996-07-01
A multiple sampling proportional counter for particle identification of relativistic heavy ions
Energy Technology Data Exchange (ETDEWEB)
A multiple sampling dE/dx counter using a multiwire proportional chamber equipped with catbode pads was constructed for the multiple detection of dE/dx values along a particle trajectory. For low-energy particles this counter was proved to be useful as a Bragg-curve detector. At relativistic energies around E=14.6 GeV/nucleon good particle identification was obtained by cathode pad signals as well as anode signals for the range of projectile fragments from Z=1 (minimum ionization) up to a beam charge of Z=14. (orig.).
1990-11-15
International Nuclear Information System (INIS)
In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component ...
2007-08-21
Boron-Lined Neutron Detector Measurements
Energy Technology Data Exchange (ETDEWEB)
Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. Reported here are the results of ...
2009-11-02
International Nuclear Information System (INIS)
This report primarily deals with three issues: the health consequences of the use of ammunition with depleted uranium cores; the health damage that radar staff may have suffered through stray X-radiation; and the way hazardous materials such as asbestos are handled in the German army. As regards uranium ammunition, the present findings suggest that there is neither reason for concern nor blame on anyone. The 31,000 American DU rounds that were fired over Kosovo in 1999 neither pose a health hazard to soldiers nor to the civil population. All that remains is a minimal risk of future groundwater contamination. The radar equipment currently in use in the German army poses no danger to operators, inspectors, service personnel or instructors provided that the relevant safety rules are observed. However, this cannot be said with the same degree of certainty with regard to the equipment used in the 1960s and 1970s. It is quite ...
On the determination of the dose-area product during X-ray examinations
International Nuclear Information System (INIS)
Despite its great usefulness in the performance of the recording procedures prescribed by the X-Ray Ordinance the dose-area product is much less frequently measured for X-ray exposures than during fluorscopic examinations. The great multitude of measuring units, mainly on account of different scales of the measuring equipments themselves, is a cause of uncertainty in clinical routine and should be eliminated as far as the circumstances would permit. As the determination of the organ dose is relevant only in very few cases and does not necessarily require previous measurements of the dose-area product, these are of limited practical value in the assessment of individual radiation exposures during radiographic examinations. The measurements may, however, be very helpful in determinations of the radiation dose to the total population, if the future retrievability of the values obtained is ensured. In addition to some measuring ...
Video equipment of tele dosimetry and audio
International Nuclear Information System (INIS)
To develop a work in an area with high radiation, it requires of a detailed knowledge of the surroundings work, a communication and effective vision, a near dosimetric control. In a work where the spaces variables and reduced accesses exist, noise that hinders the communication, defendant operative condition, radiation field and taking of decision, it is necessary to have tools that allow a total control of the environment to make opportune and effective decisions, there where the task is developed. Under this elementary concept, it was developed in the Laguna Verde Central a project that it allowed a mechanism, interactive of control in spaces complex; to see, to hear, to speak, to measure. This concept takes to the creation of an equipped system with closed circuit of television, wireless communication systems, tele dosimetry wireless systems, VHS and DVD recording equipment, uninterrupted energy ...
2007-07-01
The High-Redshift Neutral Hydrogen Signature of an Anisotropic Matter Power Spectrum
An anisotropic power spectrum will have a clear signature in the 21cm radiation from high- redshift hydrogen. We calculate the expected power spectrum of the intensity fluctuations in neutral hydrogen from before the epoch of reionization, and predict the accuracy to which future experiments could constrain a quadrupole anisotropy in the power spectrum. We find that the Square Kilometer Array will have marginal detection abilities for this signal at z~17 if the process of reionization has not yet started; reionization could enhance the detectability substantially. Pushing to higher redshifts and higher sensitivity will allow highly precise (percent level) measurements of anisotropy.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
In principle four different methods (ultrasound, microwaves, {gamma}-radiation and x-rays) are available for the non-destructive testing of refractories. Three of these methods, i.e. ultrasound, microwaves and {gamma}-radiation, are in use by different producers of AZS materials to carry out the quality control of their products. This paper will compare the three methods on the basis of the physical properties, present the existing devices, and show the advantages as well as the limits of the different methods. {gamma}-radiography, the oldest method in use, has one main disadvantage, which is the requirement of protection against radioactive radiation. Furthermore, while cracks and cavities can be detected with this method, structural changes can not be monitored. Therefore, the ultrasonic method was developed that allows to detect variations of porosity and grain size as well as ...
1995-08-01
British Library Electronic Table of Contents (United Kingdom)
Abstract A miniaturized spatial temperature gradient CE system with automated sample introduction for DNA mutation detection was established. Continuous electrokinetic sample injection was achieved by combining an automated slotted vial array sample introduction device to the spatial temperature gradient CE system. The temperature gradient was produced by a radiative heating system with a single graphite block heater, and the stability of the temperature gradient was investigated. The temperature variation of each measure point was 0.12 0.21% RSD (n=7) within 6 h. A 14 cm Teflon AF coated silica capillary was used both as the separation channel and as the liquid core waveguide tube of fluorescence signal. Under a temperature gradient from 54.8 to 59.5 C, a low range control mutation standa...
2010-01-01
Gene expression analysis after low dose ionising radiation exposure of the developing organism
International Nuclear Information System (INIS)
Measuring gene expression using microarrays is relevant to many areas of biology and medicine, such as follow up of developmental stages and diseases onset, and treatment study. Since there can be tens of thousands of distinct probes on an array, each micro array experiment can accomplish the equivalent number of genetic tests in parallel. Arrays have therefore dramatically accelerated many types of investigations. For example, microarrays can be used to identify stress response genes by comparing gene expression in challenged versus normal cells. In the Molecular and Cellular Biology lab (MCB), the micro array experiments are performed within the Genomic Platform, fully equipped to analyse either the behaviour of bacteria during long space flight, the effect of low dose ionising radiation on the developing organism in mice, or the human individual radiation sensitivity. For the low dose effect, two main stages of ...
2007-09-01
Robotics and Automation Activities at the Savannah River Site: A Site Report for SUBWOG 39F
Energy Technology Data Exchange (ETDEWEB)
The Savannah River Site has successfully used robots, teleoperators, and remote video to reduce exposure to ionizing radiation, improve worker safety, and improve the quality of operations. Previous reports have described the use of mobile teleoperators in coping with a high level liquid waste spill, the removal of highly contaminated equipment, and the inspection of nuclear reactor vessels. This report will cover recent applications at the Savannah River, as well as systems which SRS has delivered to other DOE site customers.
1995-09-28
Laboratory robotics systems at the Savannah River Laboratory
International Nuclear Information System (INIS)
Many analytical chemistry methods normally used at the Savannah River site require repetitive procedures and handling of radioactive and other hazardous solutions. Robotics is being investigated as a method of reducing personnel fatigue and radiation exposure and also increasing product quality. Several applications of various commercially available robot systems are discussed involving cold (nonradioactive) and hot (radioactive) sample preparations and glovebox waste removal. Problems encountered in robot programming, parts fixturing, design of special robot hands and other support equipment, glovebox operation, and operator-system interaction are discussed. A typical robot system cost analysis for one application is given.
1983-11-16
Fine ceramics center; Fuain seramikkusu senta
Energy Technology Data Exchange (ETDEWEB)
Fine ceramics center (JFCC) succeeded in the higher precision of thermal diffusivity measurement by the laser flash. This results are part of 'the research on thermophysical property measurement technique and standard substance of the functional material' by the intelligent establishing of a base promotion system of Science and Technology Agency. Cooperative research. thermal diffusivity with Natl. Res. Lab. of Metrology is one of the representative thermophysical property. The speed in which a heat transmits of the material is shown, and it is indispensable to the design of the high-temperature member subject. JFCC heralds the world as a standard substance for the thermal diffusivity measurement; 'TD-AL' using the alumina material is developed and is supplied in the spring in last year. Laser flash which uses laser beam for the heat source is general for the measurement. However, there was grinding undercut of slippage and heat between output of ...
1999-11-01
Artificial intelligence: the future in nuclear plant maintenance
Energy Technology Data Exchange (ETDEWEB)
The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.
1984-12-01
Artificial intelligence: the future in nuclear plant maintenance
International Nuclear Information System (INIS)
The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.
1984-09-23
Estimated fetal radiation dose from multislice CT studies
International Nuclear Information System (INIS)
It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.
X-ray fluorescence analysis as auxiliary method of restorers
International Nuclear Information System (INIS)
The principle is described of X-ray fluorescence analysis and the manner of detecting the emitted characteristic radiation. The advantages are presented of radionuclide X-ray fluorescence analysis which consist primarily in the possibility of conducting a totally non-destructive analysis, and of accurate and relatively narrow localization of the analyzed area, the simultaneous qualitative and quantitative determinations of a large number of elements in the order of concentrations 10"1 to 10"-"4%, stability of excitation radiation flux, simple design and relatively low capital costs. The so-called matrix effect is pointed to. A number of examples is given of the use of the cited method, including its use in the analysis of art objects. (J.B.).
1987-09-07
U.S. Government Capabilities to Support Analysis of Gamma Ray Data Submitted by Field Elements
Energy Technology Data Exchange (ETDEWEB)
As radiation detection in the interest of national security becomes increasingly commonplace, inevitable questions arise concerning the interpretation of data from handheld radioisotope identifiers (RIIDs). Field elements typically require fast answers to provide an effective defense and to minimize the impact on legitimate movement of people and goods. To support this need, on-call experts at Sandia, Los Alamos, and Lawrence Livermore national laboratories cooperate in resolving radiation alarms rapidly and accurately. We present an overview, describe the work in progress to improve capabilities, and report on some of the lessons learned.
2005-07-07
To the problem of the Cherenkov radiation of tachyons
International Nuclear Information System (INIS)
It is shown that the Cherenkov radiation of tachyons (CRT) in general case cannot possess axial symmetry with respect to velocity v. This implies that tachyons must be vector particles. Electric dipole is used as a vector characterising the tachyon. Formulas describing the CRT spectrum are derived taking into account the asymmetry for charged tachyon and neutral tachyon dipole with arbitrary orientation with respect to v. It is shown that both types of CRT possess the same integral characteristics. A new integral of motion specific for tachyons is found. Negative results of all attempts to detect the CRT are explained.
Energy Technology Data Exchange (ETDEWEB)
Survival curves were constructed from dose-incidence curves for apoptosis in the crypts of mouse small intestine, using the number of apoptotic cells after high doses (N{sub M}) as maximum cell population size. The mean lethal doses (D{sub 0}) for the dose range 0-0.5 Gy were calculated for each time of day. A circadian rhythm in both D{sub 0} and N{sub M} values was detected, indicating that both the number and sensitivity of radiation-induced apoptosis were changing throughout the day. (author).
1990-07-01
Coherent Synchrotron Radiation as a Diagnostic Tool for the LCLS Longitudinal Feedback System
Energy Technology Data Exchange (ETDEWEB)
The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL). To ensure the vitality of FEL lasing, a longitudinal feedback system is required together with other diagnostics. In this paper, we study the possibility of using Coherent Synchrotron Radiation (CSR) from the chicane as a diagnostic tool for bunch length feedback. Studies show that CSR is a good candidate, even for a non-Gaussian, double-horn longitudinal charge distribution as in the LCLS. We further check the possibility for detecting possible microbunching.
2005-06-15
Basic radiation sterilization properties of packaging materials
International Nuclear Information System (INIS)
The foils of various materials were irradiated with "6"0Co with an activity of 11,538 TBq. The minimum radiation dose was 25 kGy. Changes in chemico-physical properties were evaluated by infrared spectroscopy and were not detected after irradiation with 25 kGy. Packing foils were subjected to the following tests: mechanical tests, tests of weld strength, tests of impact resistance, free fall tests, permeability tests for water vapour and microbiological tests. The results of all tests were tabulated. The tests showed that the foils are impermeable for microorganisms and provided the welds are airtight the packed products remain sterile. (J.P.).
1984-11-28
3. Physical foundations and methodology of radionuclide X-ray fluorescence analysis
International Nuclear Information System (INIS)
The physical foundations are described of radionuclide X-ray fluorescence analysis (RXFA) and the table shows the values of K- and L-absorption thresholds and the K- and L-line energies of elements. The calculation of the intensity of characteristic radiation during RXFA proceeds from relations derived for conventional X-ray fluorescence analysis. The choice of the radionuclide source is ruled by the nature of the analysed substance and the used detection technique. The diagram shows the areas of radionuclide sources and the energy of the fluorescence radiation of elements. The table shows the spectra of radionuclide sources suitable for the purposes of RXFA measured by semiconductor Si(Li) and Ge(Li) detectors. (ES).
1983-12-01
Energy Technology Data Exchange (ETDEWEB)
An analyser for detecting explosives has at least one neutron source and a plurality of gamma ray detectors. An article to be analysed is moved adjacent the source and detectors and is subjected to neutrons which generate gamma rays from any nitrogen in the article. The gamma rays are detected and analysed to determine the nitrogen concentration within the article. In order to achieve an area of uniform detection there are a plurality of detectors equidistant both from the or each source and from the article to be analysed. In order to avoid a decrease in sensitivity away from the source(s) and detectors there may be a second opposing array of source(s) and detectors on the opposite side of the article. For greatest uniformity of detection, a source in one array opposes a detector in the other array and vice versa. Transmission of radiation from the analyser is kept at safe levels ...
1991-03-13
Coated semiconductor devices for neutron detection
Energy Technology Data Exchange (ETDEWEB)
A device for detecting neutrons includes a semi-insulated bulk semiconductor substrate having opposed polished surfaces. A blocking Schottky contact comprised of a series of metals such as Ti, Pt, Au, Ge, Pd, and Ni is formed on a first polished surface of the semiconductor substrate, while a low resistivity ("ohmic") contact comprised of metals such as Au, Ge, and Ni is formed on a second, opposed polished surface of the substrate. In one embodiment, n-type low resistivity pinout contacts comprised of an Au/Ge based eutectic alloy or multi-layered Pd/Ge/Ti/Au are also formed on the opposed polished surfaces and in contact with the Schottky and ohmic contacts. Disposed on the Schottky contact is a neutron reactive film, or coating, for detecting neutrons. The coating is comprised of a hydrogen rich polymer, such as a polyolefin or paraffin; lithium or lithium fluoride; or a heavy metal fissionable material. By varying the coating thickness and ...
2002-01-01
Energy Technology Data Exchange (ETDEWEB)
Genomic instability can be produced by ionising radiation, so-called radiation-induced genomic instability, and chemical mutagens. Radiation-induced genomic instability occurs in both germinal and somatic cells and also in the offspring of irradiated individuals, and it is characterised by genetic changes including chromosomal rearrangements. The majority of studies of trans-generational, radiation-induced genomic instability have been described in the male germ line, whereas the authors who have chosen the female as a model are scarce. The aim of this work is to find out the radiation-induced effects in the foetal offspring of X-ray-treated female rats and, at the same time, the possible impact of this radiation-induced genomic instability on the action of a chemical mutagen. In order to achieve both goals, the quantity and quality of chromosomal damage were ...
2008-04-02
Distributed radiation protection console system
International Nuclear Information System (INIS)
Radiation exposure control is one of the most important aspects in any nuclear facility . It encompasses continuous monitoring of the various areas of the facility to detect any increase in the radiation level and/or the air activity level beyond preset limits and alarm the O and M personnel working in these areas. Detection and measurement of radiation level and the air activity level is carried out by a number of monitors installed in the areas. These monitors include Area Gamma Monitors, Continuous Air Monitors, Pu-In-Air Monitors, Criticality Monitors etc. Traditionally, these measurements are displayed and recorded on a Central Radiation Protection Console(CRPC), which is located in the central control room of the facility. This methodology suffers from the shortcoming that any worker required to enter a work area will have to inquire about the ...
2004-02-01
Plane electrode device for multiwire detector for ionizing radiations
International Nuclear Information System (INIS)
A multiwire proportional counter type detector with thin slits instead of wires is presented. It can detect either charged particles (positive or negative) or radiation. The detector can be used as a counter or as an image converter. In radiography, it can replace photographic film or TV camera systems. It can also be used to measure particle or radiation energy. The slits which replace wires in the anode are introduced between two parallel microstrip conductors with different potentials. A quasi-polar electric field is produced between these strips. To obtain high fields, the slits are extremely narrow. Microstrips less than a micron can be obtained, giving structural dimensions of a few microns, i.e., 100 times smaller than the spacing in a classic wire anode.
1986-07-01
Detection of irradiated chicken by ESR spectroscopy of bone
Energy Technology Data Exchange (ETDEWEB)
Ionizing radiation has been used to treat poultry to remove harmful microorganisms, mainly Salmonella, which contaminates chicken, goose and other fresh and frozen poultry. This microorganism is sensitive to low dose radiation. Thus, irradiating these foods with doses between 1 to 7 kGy results in a large reduction of bacteria. Since it is necessary to determine whether irradiation has occurred and to what extend, this work studied the signal produced by ionizing radiation within the hard crystalline matrix of chicken`s bone to establish a control method. Chicken`s drumsticks were irradiated and bones separated from flesh were lyophilized and milled. ESR spectrum was then obtained. The ESR signal increased linearly with dose over the range 0.25 to 8.0 kGy. Free radicals evaluated during 30 days after irradiation showed stable in this period. (Author).
1995-10-01
Measurement of gamma-ray detection efficiency in irradiated materials examination facility
Energy Technology Data Exchange (ETDEWEB)
The detection efficiency of gamma scanning system in irradiated materials examination facility has been measured. Gamma-ray sources used in this experiment are Cs-Co standard sources a PWR spent fuel rod in which {sup 134}Cs and {sup 154}Eu peaks are clearly identified in the energy region of 500 to 1,600 keV. The distance between source and detector is about 1.6 m. A slit type collimator with 3 mm-width window and 30 mm-thick lead block are installed between source and detector. The detector is a HPGe detector. This equipment is mainly used in gamma scanning of irradiated nuclear fuel. The measured detection efficiency seems to be 1.89 x 10{sup -6} % for 1 MeV gamma-ray. With these results the activities of unknown sources could be measured. This results are expected to be used in the measurement of the absolute distribution of gamma emitting nuclides in nuclear fuel.
2001-05-01
Diagnosing mechanical changes: A test of the machine condition monitoring concept
Energy Technology Data Exchange (ETDEWEB)
BC Hydro recently conducted a demonstration test of a bearing condition monitor. The test, at the 529-MW Kootenay Canal project, proved the ability of the monitor to detect machine condition faults. The capability to detect changing conditions during normal operation of hydroelectric machines gives hydro plant owners the opportunity to anticipate needed maintenance and ultimately to reduce the number of equipment failures. BC Hydro intends to install bearing condition monitors, as well as windings monitors, brushgear monitors, environmental monitors, and other selected systems in as many as 46 of its hydro generators. BC Hydro analyzed forced outages between 1985 and 1989 in its hydro system to identify which parts of a generating unit resulted in the highest number of hours of outage. From there, the utility has formulated a concept for a machine condition monitoring system. To keep the system cost effective, it will be ...
1993-05-01
Energy Technology Data Exchange (ETDEWEB)
The Bureau of Mines recently completed peliminary studies to demonstrate the feasibility of using Ground-Penetrating Radar (GPR) for in-seam hazard detection. Investigations included air and coal tests for the purpose of checking equipment accuracy, coal penetration, and other factors such as the effects of receiver orientation. Further investigations involved using both a short pulse and a new prototype synthetic-pulse system to locate a clay vein in a coal seam using transillumination. Data were gathered on multiple travel paths, and a back-projection processing technique was then used to create a tomographic image using the calculated velocities. A computer model of the same coal seam was subsequently processed using the same tomogrpahic technique, and the results were compared with those of the actual data. Results of these preliminary studies show that GPR is feasible for use in in-seam hazard detection and point the ...
1987-01-01
Use of signal delay of one of detectors in two-channel radiometric flaw detector
International Nuclear Information System (INIS)
A possibility is considered or reducing the surface heterogeneity effect of an item being tested on the result of radiation flaw detection by means of signal delay of one of detectors in a two-channel radiometric flaw detector. The exposure of a translationally moving item has been studied as well as an external exposure of a rotating hollow item.
Test of superconducting Nb/Al bilayers as particle detectors
Energy Technology Data Exchange (ETDEWEB)
Superconducting thin film particle detectors can be very attractive due to the low sensitivity to radiation damage. We describe the fabrication procedure and the characterization of Nb/Al bilayers as particle detectors. First steady and dynamical results are reported from tests of 5 MeV alpha-particle detection.
2000-04-07
Search for tachyons associated with extensive air showers in the ground level cosmic radiation
International Nuclear Information System (INIS)
Events detected in a shielded plastic scintillation counter occurring in the 26 microsec preceding the arrival of an extensive air shower at ground level with local electron density or = 20 m to the -2 power and the 240 microsec after its arrival have been studied. No significant excess of events (tachyons) arriving in the early time domain have been observed in a sample of 11,585 air shower triggers.
1985-08-01
Lysis of phespholipid membranes with radiation-induced free radicals
International Nuclear Information System (INIS)
Phospholipid vesicles were found to be lysed by exposure to free radicals derived from irradiated glycine and galactose. The decomposition yield increased with vesicle concentration, and attained values of 0.0006 vesicles destroyed per radical added. Ionic charge at the phospholipid end groups was found to be more important than degree of unsaturation in determining this yield. Radicals derived from irradiated serine and alanine had no detectable lytic action at the vesicle concentrations tested.
1977-05-01
In vivo99mTc-HYNIC-annexin V imaging of early tumor apoptosis in mice after single dose irradiation
UK PubMed Central (United Kingdom)
BackgroundApoptosis is a major mode of hematological tumor death after radiation. Early detection of apoptosis may be beneficial for cancer adaptive treatment. 99mTc-HYNIC-annexinV...Full Text Available
Gene rearrangement and radiation carcinogenesis
International Nuclear Information System (INIS)
The development of leukemia and thyroid cancer is characterized by activation of the abl oncogene and ret oncogene, respectively. In order to clarify the relationship between these gene aberrations and radiation, the pro-myelogenous leukemia-derived cell line HL60 and the thyroid cancer-derived cell line 8505C, were irradiated in vitro with 100Gy of X-rays. RNA was then extracted from 10"8 cells of the respective cell lines and examined by the reverse transcription PCR method for rearrangements of abl and ret genes. Five kinds of positive bands were observed in the HL-60 cells irradiated with 100Gy of X-ray. Similarly, six positive bands were also observed in the 8505C cells irradiated with 100Gy. In vitro X-irradiation activation of oncogenes found in radiation induced cancers imply that gene rearrangement by X-rays is involved in the development of malignant tumors. Furthermore, in an experiment to detect ...
1993-11-01
Estimation of errors provided with dead times of roentgen digital tomography
International Nuclear Information System (INIS)
Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computer tomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained
International Nuclear Information System (INIS)
The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 (16N) and Oxygen-19 (19O) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of 19O and 16N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high ambient radiation level even though sensitivity is appreciably good. For detector position in RB in the accessible ...
2006-11-13
An experimental plan for improvement of failed fuel monitoring system in CANDU reactor
Energy Technology Data Exchange (ETDEWEB)
An experimental plan for improving the problems of failed fuel location system in Wolsung Unit-2 reactors was established. It is not possible to make an experiment on the failed fuel monitoring nuclides in the cold laboratories because they have very short half life. Therefore, the experiments can be only carried out at the existing monitoring system under reactor operation. For that reason, an experimental plan was drawn up for installing the radiation detection system on reactor site.
2003-10-01
Measuring characteristics on emissivity using infrared thermometer for RCCS
International Nuclear Information System (INIS)
In VHTGR (Very High Temperature Gas-cooled Reactor), the radiation plays an important role in heat transfer through the cavity in RCCS (Reactor Cavity Cooling System). We performed the series of experiments to measure the emissivity using the infrared thermometer with wavelength range of 8#approx#14 #mu#m. As the first step, the transmittance of Zinc Selenide (ZnSe) window was measured to estimate the emissivity that can compensate the attenuation effect of window. The kind of gas with various concentrations in the cavity will be released during postulated accidents to the coolant type, so it is essential to estimate the effects of gas on the measurement of emissivity. In this manner we measured the emissivity with the air, the helium and the steam inside chamber. The results represent that the concentration of the air and the helium do not affect the emissivity significantly while the steam decreases the measured emissivity relatively. It means that the air and ...
2004-12-01
Gravitational waves interferometer and the VIRGO project
Radio, optical and X-rays telescopes are improving our knowledge of deep space. All these telescopes detect electromagnetic radiation at various frequencies. But a different kind of radiation is generated in the deeper space; it is the gravitational one. Gravitational waves change the space-time metric. As a consequence, GW telescopes should detect an extremely small strain (h < 10/sup -21/) of the geometry of a reference frame; if the frame has a reference dimension (L) of some kilometers, the deformation amplitude ( Delta L = h * L) is limited to 10/sup -16/ meters. Laser interferometers are the most suitable devices to make precise measurements of distances. Their resolution is limited by the laser wavelength ( lambda = 10/sup -6/ meters) and by the light wave-shift detection capability ( Delta Phi = 1 ppb). These theoretical limits are strongly degraded by different noise ...
2002-01-01
Computed radiography. Evaluation of its role in the mass survey for lung cancer: Phantom study
Energy Technology Data Exchange (ETDEWEB)
In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in the retrocardiac and subdiaphragmatic regions, respectively. This may have ...
1987-12-01
International Nuclear Information System (INIS)
In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in the retrocardiac and subdiaphragmatic regions, respectively. This may have ...
1987-01-01
Assessing the internal mechanical integrity of power transformers using vibration tests
Energy Technology Data Exchange (ETDEWEB)
Machine condition monitoring (MCM) has the capability to predict equipment maintenance needs which can reduce forced down-time and facilitate the avoidance of catastrophic failures and the consequential secondary damage. It can be used to allow confident deferral of routine maintenance, and improve equipment performance, availability, reliability and safety. In order to capitalize on the potential benefits of MCM directed toward power transformers two types of vibration tests were conducted on transformers owned and operated by Cargill Inc. and IES Utilities at the Bridgeport corn plant in Eddyville, Iowa. These tests involved collecting vibration signals from the transformer tank walls during transformer energization at no-load and during steady state operation at various loads. These vibration signals were then used to detect deterioration of internal mechanical integrity. Both types of tests conducted on the transformers ...
1996-12-31
Radioanalytical methods of rare earth element determination
International Nuclear Information System (INIS)
Instrumental neutron activation analysis (INAA) and radionuclide X-ray fluorescence analysis (RXFA) were used for the determination of rare earth elements. For INAA, solution obtained by sample decomposition was dripped onto filter paper, enclosed and sealed into a polyethylene foil. The sample was activated in reactor WWR-S over a period of 4 to 6 hours with a neutron fluence of 10"1"3cm"-"2. Gamma radiation measurement was carried out with a planar and a coaxial HP-Ge detector in three decay periods. La, Ce, Nd, Sm, Eu, Gd, Tb, Ho, Tm, Yb and Lu were determined. The advantage of the method is its accuracy and high sensitivity, the disadvantage is the time-consuming analysis. The RXFA method was used as a rapid and operative method for the analysis of loose ore samples, aqueous and organic solutions of rare earth elements. For exciting X-ray radiation, "2"4"1Am was used and the radiation of K-lines was ...
1989-06-01
Magnetospheric Emissions from the Planet Orbiting tau Boo: A Multi-Epoch Search
All of the solar system gas giants produce electron cyclotron masers, driven by the solar wind impinging on their magnetospheres. Extrapolating to the planet orbiting tau Boo, various authors have predicted that it may be within the detection limits of the 4-meter wavelength (74 MHz) system on the Very Large Array. This paper reports three epochs of observations of tau Boo. In no epoch do we detect the planet; various means of determining the upper limit to the emission yield single-epoch limits ranging from 135 to 300 mJy. We develop a likelihood method for multi-epoch observations and use it to constrain various radiation properties of the planet. Assuming that the planet does radiate at our observation wavelength, its typical luminosity must be less than about 10^{16} W, unless its radiation is highly beamed into a solid angle Omega << 1 sr. While within the range of ...
2007-01-01
Development of a dual-detector X-ray imaging system for phase retrieval study
International Nuclear Information System (INIS)
Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two detectors, respectively ...
2007-01-01
Aging and compatbility of TNF-doped mylar
Energy Technology Data Exchange (ETDEWEB)
TNF-doped Mylar is a new radiation-hard dielectric that has recently been qualified as a viable substitute for Mylar in capacitors. The advantage of TNF-doped Mylar is that it satisfies both the nuclear safety and radiation hardness requirements of weapons. Mylar is not radiation-hard. Aging and compatibility studies were carried out to insure that (1) TNF does not diffuse from the film during fabrication of the capacitor or during storage; and (2) there are no compatibility problems with aluminum foil (the conductor) or Fluorinert (the secondary dielectric). Losses of TNF were barely detectable during the vacuum bakes used in fabricating capacitors or during accelerated aging tests carried out below T{sub g} (70C) over a two year period in air. In other accelerated tests, no compatibility problems were detected with aluminum or Fluorinert. TNF-doped Mylar is now being used in the ...
1990-01-01
Introduction Uchide and Ide [SSA Spring Meeting, 2009] proposed a new framework for studying the scaling and overall nature of earthquake rupture growth in terms of cumulative moment functions. For better understanding of rupture growth processes, spatiotemporally local processes are also important. The nature of high-frequency (HF) radiation has been investigated for some time, but its role in the earthquake rupture process is still unclear. A wavelet analysis reveals that the HF radiation (e.g., 4 - 32 Hz) of the 2004 Parkfield earthquake is peaky, which implies that the sources of the HF radiation are isolated in space and time. We experiment with applying a matched filter analysis using small template events occurring near the target event rupture area to test whether it can reveal the HF radiation sources for a regular large earthquake. Method We design a matched filter for multiple components and ...
2009-12-01
Energy Technology Data Exchange (ETDEWEB)
A multi-stage, multi-disk type seismic source was developed as a downhole seismic source. The seismic source is an improved version of the downhole seismic source of a system in which an elastic wave is generated by a weight accelerated by restitutive force of a spring striking the upper part of a laminated structure consisted of metal disks and elastic bodies installed in water in a well. Enhancing the vibration exciting efficiency requires impedance radiated from the disks to be increased. The multi-disk structure was adopted because of restrictions on the disk area under the limiting condition of being inside the well. Further limitation has still existed, which led to finally structuring the multi-disk type to a multi-stage construction to increase the radiated impedance. In order to increase average velocity on the radiation surface, mass relationship between the hammer and the anvil was sought so that the maximum ...
1997-05-27
Sensor test facilities and capabilities at the Nevada Test Site
Energy Technology Data Exchange (ETDEWEB)
Sandia National Laboratories has recently developed two major field test capabilities for unattended ground sensor systems at the Department of energy`s Nevada Test Site (NTS). The first capability utilizes the NTS large area, varied terrain, and intrasite communications systems for testing sensors for detecting and tracking vehicular traffic. Sensor and ground truth data can be collected at either of two secure control centers. This system also includes an automated ground truth capability that consists of differential Global Positioning Satellite (GPS) receivers on test vehicles and live TV coverage of critical road sections. Finally there is a high-speed, secure computer network link between the control centers and the Air Force`s Theater Air Command and Control Simulation Facility in Albuquerque NM. The second capability is Bunker 2-300. It is a facility for evaluating advanced sensor systems for monitoring activities in underground cut-and-cover facilities. ...
1996-12-31
Detection of concealed mercury with thermal neutrons
Energy Technology Data Exchange (ETDEWEB)
In the United States today, governments at all levels and the citizenry are paying increasing attention to the effects, both real and hypothetical, of industrial activity on the environment. Responsible modem industries, reflecting this heightened public and regulatory awareness, are either substituting benign materials for hazardous ones, or using hazardous materials only under carefully controlled conditions. In addition, present-day environmental consciousness dictates that we deal responsibly with legacy wastes. The decontamination and decommissioning (D&D) of facilities at which mercury was used or processed presents a variety of challenges. Elemental mercury is a liquid at room temperature and readily evaporates in air. In large mercury-laden buildings, droplets may evaporate from one area only to recondense in other cooler areas. The rate of evaporation is a function of humidity and temperature; consequently, different parts of a building may be sources or sinks of mercury ...
1994-08-18
Measuring equipment for the monitoring of air pollution control - a market review
Energy Technology Data Exchange (ETDEWEB)
The paper abstracted gives a tabular survey of the suppliers and applications of measuring equipment. Equipment is available for the following fields of application: Continuous measuring instruments for stationary operation, laboratory equipment for sampling and hand equipment for mobile measurement, sampling equipment for examining emissions and gases, detectors, storage and evaluation equipment and meteorological instruments. (PW).
1986-01-01
Study of radionuclide contributing to dose rates in 540 MWe plant environment
International Nuclear Information System (INIS)
Tarapur Atomic Power Station Unit-4 is first 540 MWe pressurized heavy water reactor in India. It achieved criticality on 06th March 2005 and then operated at full power i.e 500 MWe. Radiation workers during the normal operation and reactor shutdown are exposed to radiation field. The control of dose rates and the collective dose of the radiation workers is most important for the best performance of the reactor. Experience gained during the operation of the 220 MWe reactors has shown that the Moderator system, primary heat transport system, annulus gas system and moderator cover gas system are the main systems contributing to the dose rate and collective dose. In order to identify the radio nuclides contributing to the radiation field, study was undertaken at TAPS Unit-4. Various samples from the Moderator, primary heat transport system, annulus gas system and moderator cover gas system were collected ...
2005-11-23
Radiation-hardening of magnet coils
International Nuclear Information System (INIS)
The first essential before embarking on the radiation-hardening of electrical insulation - mostly magnet coils - in any beam line application is to obtain a reliable estimate of the dose to the components. These are examples ( switchyards at SLAC and LAMPF) where the degree of hardness specified was much higher than was required. Although experience shows that the cost premium for substantial radiation - hardening is of the order of 10%, it has also become clear that well - designed beam line have negligible losses: hardening is required only in the vicinity of targets, collimators or other beam - intercepting devices. Where the beam is deliberately scraped, local shielding will minimize the associated radiation in the surroundings. Electron machines have their own special problems due to synchrotron radiation, so certainly coils and other electrical equipment should be kept away ...
1989-03-01
Measurement of magnetic fields in the Area Metropolitana
International Nuclear Information System (INIS)
The operation and proper handling of equipment for measuring EMR-300 electromagnetic waves are studied and apply that knowledge to determine which areas of the metropolitan area are mostly affected by exposure to the emission of radiation. This team is able to measure magnetic field strength, electric field strength and power density, also can measure the most important parameters in a simple manner. International standards provide maximum values for these parameters that limit human exposure to such radiation. These standards are based on epidemiological several and laboratory that have been carried out in order to determine in which circumstances a biological entity is exposed to a level of radiation that can cause harm to their health. It focuses on measuring the level of radiation in certain areas of interest, which were chosen because are areas with high population density and ...
Preliminary studies on the detection of irradiated prawns using 2-alkylcyclobutanones
Energy Technology Data Exchange (ETDEWEB)
The use of ionising radiation for the preservation of food has been under investigation for many years but has yet to receive worldwide acceptance. Although irradiation can be carefully controlled, it is generally accepted that the development of a test or tests for the detection of irradiated food would enhance consumer confidence and might help to enforce labelling regulations. The 2-alkylcyclobutanones are reported to be the only cyclic compounds formed as the products of the radiolysis of saturated and unsaturated triglycerides. The synthesis of 2-dodecylcyclobutanone (DCB) and 2-tetradecylcyclobutanone (TCB), which are formed from palmitic and stearic acid respectively following irradiation, has been carried out and using irradiated chicken meat as the model for a high-lipid containing food, both cyclobutanones have been extracted with hexane and then identified using gas chromatography/mass spectrometry (GC/MS). DCB and TCB have been ...
1996-12-31
International Nuclear Information System (INIS)
The Gross Decontamination Experiment was conducted on various levels and surfaces of the TMI-2 Reactor Building during February and March 1982 and was designed to investigate the effectiveness of various surface decontamination techniques. The polar crane, D-rings, missile shields, refueling canal, fueling bridge, major equipment, floors and some walls were flushed with low pressure water. Water lances were directed manually and applied water at temperatures between ambient and 60"0C at a flow rate of about 95 liters per minute. In addition, floor surfaces on the 305-ft elevation and floor surfaces and major equipment on the 347-ft elevation were sprayed with high pressure water (floors in the Reactor Building are designated by their elevations above sea level). The water pressure in this case varied between 13.8 and 41.4 mPa and water temperature was at a maximum 60"0C. Certain surfaces were also decontaminated using either strippable coatings ...
1984-07-15
Measurement of snow water storage in the Lake Saperior basin using aerial gamma-ray spectrometry
International Nuclear Information System (INIS)
A pilot project was started in 1977 over the Lake Superior basin to measure water storage on the land area using aerial gamma-ray spectrometry to provide hydrologic information for forecasting inflow to the lake. Two airborne surveys were made, respectively in November 1977 and March 1978 which provided estimates of the increase in snow water equivalent between these surveys. The basin is located on the Canadian Shield and consequently, the gamma radiation count rate is quite variable. The airborne results are compared with ground measurements on selected flight lines and show generally good agreement. Two equipment calibrations in the Ottawa area provided inconsistent parameter values which are consequently also reflected in the results over the Lake Superior basin. The project has demonstrated to-date that the technique can be developed into an operational system for measuring snow cover water equivalent of this vast and remote area by using ...
1977-11-01
Tunnel Sensors Equipment on Environmental Expert
... Tunnel Sensors Equipment on Environmental Expert Find and compare a variety of tunnel sensors equipment on the world's largest environmental industry portal. View ...
Geothermal Energy Equipment in Finland on Environmental Expert
... Geothermal Energy Equipment in Finland on Environmental Expert Find and compare a variety of geothermal energy equipment in finland on the world's largest environmental ...
Geothermal Energy Equipment in Belgium on Environmental Expert
... Geothermal Energy Equipment in Belgium on Environmental Expert Find and compare a variety of geothermal energy equipment in belgium on the world's largest environmental ...
Fuel Cell Technologies Equipment on Environmental Expert
... Fuel Cell Technologies Equipment on Environmental Expert Find and compare a variety of fuel cell technologies equipment on the world's largest environmental industry portal. View ...
Corrosive Fumes Equipment on Environmental Expert
... Corrosive Fumes Equipment on Environmental Expert Find and compare a variety of corrosive fumes equipment on the world's largest environmental industry portal. View ...
Corrosion Inhibitors Equipment on Environmental Expert
... Corrosion Inhibitors Equipment on Environmental Expert Find and compare a variety of corrosion inhibitors equipment on the world's largest environmental industry portal. View ...
Biogas Analyzers Equipment on Environmental Expert
... Biogas Analyzers Equipment on Environmental Expert Find and compare a variety of biogas analyzers equipment on the world's largest environmental industry portal. View ...
Supervision monitoring for radiation environment around Daya Bay and Lingao nuclear power stations
International Nuclear Information System (INIS)
This paper systematically introduces the supervision monitoring for radiation environment around the Guangdong Daya Bay and Ling Ao nuclear power station by the Guangdong Environmental Radiation Research and Monitoring Center. It includes the monitoring plan, methods, quality assurance, main results and conclusions. The results show that: (1) The gas discharge have not caused any detectable impacts to the terrestrial and atmospheric environment since their operation; (2) "1"1"0"mAg could only be detected in seawater in the West Daya Bay in 1995 and 1997 and in sediments in 1997. The maximum annual average in seawater was 3.1 Bq/m"3, annual average of "1"1"0"mAg in sediments was 1.0 Bq/kg(dry). But it was always detectable in pearl oyster, gulfweed and cuttlefish in the West Daya Bay. The "1"1"0"mAg concentrations in halobios were relatively higher in 1994, 1996 and 1997. The maximum ...
2004-05-01
Energy Technology Data Exchange (ETDEWEB)
Our objective was to evaluate the feasibility of ultra-low-dose scanning for multislice CT colonography in the detection of colorectal lesions. Twenty-seven patients (14 men, 13 women) with clinical indication for conventional colonoscopy were recruited. Multislice spiral CT (Somatom Plus 4 Volume Zoom, Siemens, Germany) examinations were performed after standard oral colonoscopic preparation and colonic distension with room air. Images were acquired using 2.5-mm collimation, 3.0-mm slice thickness, standard reconstruction kernel, 140 kVp, and 10 mAs. Supine and prone acquisitions were obtained in all patients. Images were analyzed on a workstation by two gastrointestinal radiologists. Conventional colonoscopy was performed on the same day in all patients and represented the standard of reference. Total radiation exposure was also calculated. All colorectal cancers were correctly identified at CT colonography (9 of 9, sensitivity 100%). The CT ...
2003-06-01
International Nuclear Information System (INIS)
Full text: DNA rearrangement events leading to chromosomal aberrations are central to ionizing radiation-induced cell death. Although DNA double-strand breaks are probably the lesion that initiates formation of chromosomal aberrations, little is understood about the molecular mechanisms that generate and modulate DNA rearrangement. Examination of the sequences that flank sites of DNA rearrangement may provide information regarding the processes and enzymes involved in rearrangement events. Accordingly, we developed a method using inverse PCR that allows the detection and sequencing of putative radiation-induced DNA rearrangements in defined regions of the human genome. The method can detect single copies of a rearrangement event that has occurred in a particular region of the genome and, therefore, DNA rearrangement detection does not require survival and continued multiplication of ...
2003-08-17
International Nuclear Information System (INIS)
The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For detector position out side the RB containment, the travel time for ...
2005-11-23
[Reactive collisions of high-temperature systems]. [Technical progress report 1990
Energy Technology Data Exchange (ETDEWEB)
The object of this research is to study reactivity at superthermal collision energies using a fast neutral beam that is generated by photodetachment. Systems scheduled for initial study include basic oxygen-hydrogen reactions. Unfortunately, we can not yet report realization of this goal, but during this funding period we have made advances that are anticipated to lead to successful measurements during the next year. The parameters described below refer to the model system O + H{sub 2} {yields} OH + H. The basic design involves the collision of fast neutrals, created by photodetachment of the corresponding negative molecular ion, with a stable reactant gas in a collision cell. Products are detected by ionization and mass analysis. We are equipped to study rotational effects on reactivity by comparing results for rotational levels J = 0 and 1 of H{sub 2}. Highlights during the funding period are given in this report.
1990-12-31
British Library Electronic Table of Contents (United Kingdom)
This paper describes a state-of-the-art online monitoring system using multivariate statistical technologies for continuous steel casting process, which was commissioned at Dofasco's No. 2 caster to provide consistent indication of process health for caster's start-up, continuous production and transitional operations. The paper particularly focuses on development of a novel scheme to synchronize process trajectories for monitoring specific transitional operations such as equipment or steel product grade changes. The proposed scheme is demonstrated by several industrial examples with the results showing good detectability of various process abnormalities. With the aid of this fully integrated, innovative monitoring system, Dofasco has generated significant value through improved productivi...
2006-01-01
Headspace gas chromatographic method for determination of methyl bromide in food ingredients
Energy Technology Data Exchange (ETDEWEB)
A headspace gas chromatographic (GC) method, which can be automated, has been developed for determination of methyl bromide. This method has been applied to wheat, flour, cocoa, and peanuts. Samples to be analyzed are placed in headspace sample vials, water is added, and the vials are sealed with Teflon-lined septa. After an appropriate equilibration time at 32 degrees C, the samples are analyzed within 10 h. A sample of the headspace is withdrawn and analyzed on a gas chromatograph equipped with an electron capture detector (ECD). Methyl bromide levels were quantitated by comparison of peak area with a standard. The standard was generated by adding a known amount of methyl bromide to a portion of the matrix being analyzed and which was known to be methyl bromide free. The detection limit of the method was 0.4 ppb. The coefficient of variation (CV) was 6.5% for wheat, 8.3% for flour, 3.3% for cocoa, and 11.6% for peanuts.
1985-11-01
Self-assessment of current knowledge in nuclear medicine (second edition)
Energy Technology Data Exchange (ETDEWEB)
In this updated second edition, the order of contents of the textbook has been reorganized. It has been divided into main parts: Basic Science and Clinical Nuclear Medicine. Basic Science, Part I, encompasses basic physics, radiation protection, interaction of radiation with matter and radiation detection, imaging, nuclear pharmacy, and radiation biology. Part II, Clinical Nuclear Medicine, covers the central nervous system, bone, gastroenterology (liver/spleen), cardiovascular system, pulmonary system, genitourinary system, thyroid and endocrine systems, gallium studies, radioassay, hematology, and therapy. The total number of pages of the current edition is increased to 250 from the 213 of the first edition but there are fewer questions because those in the basic science area have been carefully selected to 60 of the original 98 questions. Compared with the previous edition, there ...
1981-01-01
Salmonella radicidation of poultry carcasses
International Nuclear Information System (INIS)
This thesis reports investigations using gamma-radiation to decontaminate poultry carcasses. The application to foods of doses of ionizing radiation sufficient to reduce the number of viable specific non-sporeforming pathogenic microorganisms so that none is detectable in the treated food by any standard method is termed radicidation. The doses used in this study were at such a level that no undesirable or unfavourable side-effects occurred. The effects of these doses were studied on salmonellae and other microorganisms present in, or associated with poultry carcasses and in liquid and on solid culture media as well. Decimal reduction (D_1_0) values were estimated. These represent the dose (kGy) required to achieve a reduction in initial colony count from N_0 to 0.1 N_0. Together with the estimation of the numbers of Salmonella present per carcass the data were used to predict the effect of an ionizing ...
2005-09-22
Recurrent plot analysis of discharge sequences in tracking test of polybutylene polymers
Energy Technology Data Exchange (ETDEWEB)
Polymers are required to use in radiation environments as insulation materials. However, they often suffer from tracking failure. There is an increasing demand to evaluate radiation effects on dielectric performance. This paper presents a recurrence plot (RP) approach to analyse surface discharge sequences of gamma-ray irradiated polymer materials based on tracking test. Studying the non-linear characteristics of discharge sequences can assist in understanding the underlying mechanism of the discharge process. Discharge sequences of the test are extended to m-dimensional phase space by using the phase space reconstructed method. As test samples, polybutylene terephthalate (PBT) and polybutylene naphthalate (PBN) were irradiated to 100 kGy and then up to 1 MGy with a dosage rate of 10 kGy h{sup -1} by using a {sup 60}Co gamma source. The tracking tests were carried out according to the test method described in IEC60112. It is found that the RPs ...
2008-10-07
Low dose effects - is the fear more dangerous than the radiation?
Energy Technology Data Exchange (ETDEWEB)
The use of hypothesis which assumes a dose / harmful effect relationship without a limit allows the calculation of risks attributable to doses too small to produce detectable, harmful biological effects. The daughter product of this hypothesis is ALARA concept which requires that the dose received is kept as low as reasonably achievable. This concept of prudent avoidance is generally accepted by international radiation protection organisations and universally applied by radiation health professionals. The acceptance of a hypothesis which assumes that a single nuclear event can cause carcinogenesis, has generated levels of anxiety which may have resulted in significant detriment to those possibly exposed to ionising radiation. The anxiety generated may have caused more detriment and a higher death rate than the worst case ` theoretical` value calculated using the Linear or Quadratic Linear Hypothesis. ...
1996-01-01
Energy Technology Data Exchange (ETDEWEB)
Safety standards for exposure to radiofrequency radiation must be based upon biologic consequences of exposure to such environments. Behavioral-based measures are considered to be the most-sensitive indices of biological effects. Current safety guidelines are based upon average power density and may not be relevant to the high-peak-power, short pulse width microwave radiation produced by newly developed high peak power microwave sources. The effects of exposure to high-peak-power radiation on reflexive responding and motor function in Fischer 344/N rats were assessed by measuring startle and general activity, and disruption of on-going performance of a rotarod task, respectively. The emitter used was the TEMPO repeat pulse axially extracted vircator. Exposure to single pulses resulted in significant startle responses. Exposure to 1 pps for 10 s produced significant alterations in baseline activity and marked disruption of ...
1988-03-01
Energy Technology Data Exchange (ETDEWEB)
This study presents results from Monte Carlo radiation transport calculations aimed at characterizing a novel methodology being developed to detect partial defects in Pressurized Water Reactor (PWR) spent fuel assemblies (SFAs). The methodology uses a combination of measured neutron and gamma fields inside a spent fuel assembly in an in-situ condition where no movement of the fuel assembly is required. Previous studies performed on single isolated assemblies resulted in a unique base signature that would change when some of the fuel in the assembly is replaced with dummy fuel. These studies indicate that this signature is still valid in the in-situ condition enhancing the prospect of building a practical tool, Partial Defect Detector (PDET), which can be used in the field for partial defect detection.
2008-04-28
Real-time neutron monitoring method using an imaging plate
Energy Technology Data Exchange (ETDEWEB)
A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)
1999-07-01
Real-time neutron monitoring method using an imaging plate
International Nuclear Information System (INIS)
A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)
1999-04-19
Authentication of byte sequences
Energy Technology Data Exchange (ETDEWEB)
Algorithms for the authentication of byte sequences are described. The algorithms are designed to authenticate data in the Storage, Retrieval, Analysis, and Display (SRAD) Test Data Archive of the Radiation Effects and Testing Directorate (9100) at Sandia National Laboratories, and may be used in similar situations where authentication of stored data is required. The algorithms use a well-known error detection method called the Cyclic Redundancy Check (CRC). When a byte sequence is authenticated and stored, CRC bytes are generated and attached to the end of the sequence. When the authenticated data is retrieved, the authentication check consists of processing the entire sequence, including the CRC bytes, and checking for a remainder of zero. The error detection properties of the CRC are extensive and result in a reliable authentication of SRAD data.
1991-06-01
Energy Technology Data Exchange (ETDEWEB)
Although the Federal Facility Agreement (FFA) addresses the entire Oak Ridge Reservation, specific requirements are set forth for the liquid low-level radioactive waste (LLLW) storage tanks and their associated piping and equipment, tank systems, at ORNL. The stated objected of the FFA as it relates to these tank systems is to ensure that structural integrity, containment and detection of releases, and source control are maintained pending final remedial action at the site. The FFA requires that leaking LLLW tank systems be immediately removed from service. It also requires the LLLW tank systems that do not meet the design and performance requirements established for secondary containment and leak detection be either upgraded or replaced. The FFA establishes a procedural framework for implementing the environmental laws. For the LLLW tank systems, this framework requires the specified plans and schedules be submitted to EPA ...
1992-03-01
Energy Technology Data Exchange (ETDEWEB)
ACRO, a NGO equipped with a laboratory to measure radioactivity, runs the Citizen Watchdog of Radioactivity in the Environment. Involving many volunteers, it monitors regularly the French coast of the Channel and many rivers of the North half of France. It also makes investigations in other places. Such an action is aimed to supplement the official monitoring, not to replace it, in order to answer to the worries of the population. This monitoring shows that some radioelements, such as iodine 129, cobalt 60, tritium, etc. released in the environment by nuclear facilities can be detected on very large areas. Carbon 14 was detected up to almost 4 times the background in vegetables around the reprocessing plant of La Hague. ACRO also sits in many official committees to transmit the point of view of the populations exposed to the radioactive pollution. It is lobbying for a decrease of the release authorization, especially for ...
2010-06-15
Energy Technology Data Exchange (ETDEWEB)
A Bragg curve counter equipped with an internal production target was developed for the measurements of double-differential cross-sections of fragment production induced by neutrons at energies of tens of MeV. The internal target permitted a large detection solid angle and thus the registration of processes at low production rates. In this specific geometry, the detection solid angle depends on the emission angle and the range of the particle. Therefore the energy, atomic number, and angle of trajectory of the particle have to be taken into account for the determination of the solid angle. For the selection of events with tracks confined within a defined cylindrical volume around the detector axis, a segmented anode was applied. The double-differential cross-sections for neutron-induced production of lithium, beryllium, and boron fragments from a carbon target were measured at 0 deg. for 65 MeV neutrons. The results are in ...
2009-11-11
Radiation-induced damage to DNA; Les lesions radio-induites de l'ADN
Energy Technology Data Exchange (ETDEWEB)
This short survey focuses on the main radiation-induced base lesions that have been identified within cellular DNA. For this purpose, sensitive assays that are aimed at measuring a few modifications per 10{sup 7} normal bases were set-up. In that respect high performance liquid chromatography - tandem mass spectrometry (CLHP-MS/MS) was found to be able to single out the formation of 9 oxidized nucleosides and two modified nucleo-bases out of the 70 oxidative base lesions that have been identified in model systems. As a striking result, it was found that in the DNA of {gamma}-irradiated human monocytes, the formamide-pyrimidine derivative of guanine is produced in a higher yield than the ubiquitous 8-oxo-7,8-dihydro-guanine damage, both arising from the same radical precursor. However, relatively high doses of ionizing radiation (> 20 Gy) have to be applied in order to detect an increase in the level of the damage. ...
2002-03-01
Radioexposure of children in cranial examinations with new-generation CT equipment
Energy Technology Data Exchange (ETDEWEB)
Using phantoms of children simulating a child of 6 months of age and another one aged 6 years, the authors measured the amount of radioexposure of the lens of the eye, the thyroid and of the gonads. The two computer tomographs Somatom SF and Tomoscan 300 under examination, produced radiodoses of comparable magnitudes. Both devices allow additional examination techniques of particularly high economy. It was found that in cranial CT the exposure of the lens to radiation is generally below 1 R if the orbitae are not situated in the plane of section. If a distance of 2-3 cm is maintained from the orbitae, the dose remains below 0.5 R. Protecting the gonads is meaningful in a 6-year-old boy, whereas covering-up of the thyroid reduced the dose only slightly.
1983-04-01
Quartz fiber calorimetry and calorimeters
Quartz fiber calorimetry is a technique the signal generation mechanism of which is based on the Cherenkov effect. In this article we try to give a comprehensive overview of the subject. We start with a general introduction to calorimetry where the basic elements that characterize the development of electromagnetic and hadronic showers are discussed. Then we describe in detail the operation principle and the properties of calorimeters equipped with quartz fibers. The main advantages of this type of calorimeters are the radiation hardness, the fast response and the compact detector dimensions, features that derive from the quartz material and the specific mechanism of operation. A section is devoted to presenting the quartz fiber calorimeters that have been built or planned to in various experiments to operate as centrality detectors, trigger detectors, luminosity monitors or general purpose very forward calorimeters.
2004-01-01
Lessons learned from accidents in industrial radiography
International Nuclear Information System (INIS)
Industrial radiography accounts for approximately half of all the reported accidents for the nuclear related industry, in both developed and developing countries. This Safety Report is the result of a review made of a large selection of accidents in industrial radiography reported by regulatory authorities, professional associations and scientific journals. A small, representative selection of 43 accident descriptions has been used to illustrate the primary causes of radiography accidents, and a set of measures provided to prevent the recurrence of such accidents or to mitigate the consequences of those that do occur. These accident descriptions were categorized by primary causes as follows: inadequate regulatory control; failure to follow operational procedures; inadequate training; inadequate maintenance; human error; equipment malfunction or defect; design flaws; and wilful violation. The information in this Safety report is intended for use by those regulatory ...
30 CFR 77.1606 - Loading and haulage equipment; inspection and maintenance.
...2010-07-01 false Loading and haulage equipment; inspection and maintenance... § 77.1606 Loading and haulage equipment; inspection and maintenance. (a) Mobile loading and haulage equipment shall be inspected by a...
2010-07-01
30 CFR 75.1403-10 - Criteria-Haulage; general.
...persons from danger of runaway haulage equipment. (f) An audible warning...within 300 feet of preceding haulage equipment, except trailing locomotives...provided for all rubber-tired haulage equipment where such equipment is...
2010-07-01
29 CFR 1926.602 - Material handling equipment.
...Pneumatic-tired earth-moving haulage equipment (trucks, scrapers, tractors...Pneumatic-Tired Earthmoving Haulage Equipment. An employer may, of course...pneumatic-tired earthmoving haulage equipment, is suspended pending...
2009-07-01
On-site radiation exposure in severe reactor accidents: Scoping study
Energy Technology Data Exchange (ETDEWEB)
The results of a scoping study of onsite radiation exposures which could take place in each of three types of postulated reactor accidents are presented. The accident types are (1) a fuel handling accident at a Mark III BWR; an interfacing system LOCA or V sequence at a PWR; and and Anticipated Transient Without Scram (ATWS) at a Mark I BWR. Both external and internal dose pathways are considered. The results of the study indicate the prohibitively high radiation doses could be received in some plant areas if personnel were to remain there. However, times of the order of a few minutes to a few hours, depending on the type of accident, would be available before life-threatening doses would be accumulated assuming that the provided full face respiratory protection equipment were used promptly. Special attention was given radiation doses possibly received by control room personnel for several control room ...
1990-09-01
Food packaging and radiation sterilization
International Nuclear Information System (INIS)
Radiation sterilization has several merits that it is a positively effective sterilization method, it can be used to sterilize low heat-resistant containers and high gas barrier films, and there is no possibility of residual chemicals being left in the packages. It has been commercially used in 'Bag in a Box' and some food containers. The #gamma# ray and an electron beam are commonly used in radiation sterilization. The #gamma# ray can sterilize large size containers and containers with complex shapes or sealed containers due to its strong transmission capability. However, since the equipment tends to be large and expensive, it is generally used in off production lines. On the other hand, it is possible to install and electron beam system on food production lines since the food can be processed in a short time due to its high beam coefficient and its ease of maintenance, even though an electron beam has limited usage such ...
1998-12-08
Use of radiosensitivity to identify irradiated fresh poultry products
International Nuclear Information System (INIS)
Microbiological comparison between irradiated and non-irradiated foodstuff has been studied for a long time as a way to detect whether a foodstuff has been irradiated or not. Generally, the proposed methods are based on the fact that ionization select species of bacteria which are recognized to be radioresistant. So reduction or elimination of known radiation sensitive microbes from the normal endogenous microflora could give an indication that the foodstuff has been irradiated, predominance of known radioresistant bacteria should be another indication. In the present work, we try to develop a test based on the radiosensitivity of the bacteria independently of their place. These first experiments show that the determination of radiosensitivity of strains isolated from a product or even of global radioresistance of mesophilic microflora could indicate if this product has been previously submitted to ionizing radiations. (4 ...
1990-02-14
International Nuclear Information System (INIS)
A high-density gas jet supersonic nozzle is reported in this paper. The jitter and actuation time of the nozzle is determined by the pin discharge and laser spark radiation respectively. The jitter time of the nozzle is within 10 ?s with the backing pressure as high as 25 bar. With a nanosecond laser pulse focused on the gas jet about 1 mm below the nozzle, the actuation time is calculated to be about 15 ms by detecting the laser produced spark radiation, which reveals the existence of the gas jet and the relative gas density evolving with time. Consequently the gas density is estimated to be well above 1019 cm-3, compared with theoretical simulations from the nozzle parameters.
2006-07-01
Superconducting strip detectors as position sensitive particle detectors
Energy Technology Data Exchange (ETDEWEB)
The feasibility of using of current-biased superconducting strips for radiation detection is investigated. Narrow Ta strips are exposed to 5.5 MeV [alpha]-particle radiation and the rise-time of the induced voltage pulses is measured as function of temperature and bias current. The rise-time of the voltage signal strongly depends on the site on the strip which is hit by the [alpha]-particle. In order to determine the spatial resolution of a superconducting strip detector, position-sensitive measurements were performed. The maximum lateral resolution estimated so far is 25[mu]m in a 7[mu]m wide, 340 nm thick and 0.6 mm long Ta-strip. (orig.)
1994-02-01
Point defects in dilute nitride III-N-As and III-N-P
International Nuclear Information System (INIS)
We provide a brief review of our recent results from optically detected magnetic resonance studies of grown-in non-radiative defects in two most important dilute nitride systems-Ga(In)NAs grown on GaAs substrates and Ga(Al,In)NP grown on Si and GaP substrates. These results have led to the identification of defect complexes in the alloys, involving intrinsic defects such as As_G_a antisites and Ga_i self-interstitials. They have also shed light on formation mechanisms of the defects and on their role in non-radiative carrier recombination that is harmful to the performance of potential optoelectronic and photonic devices based on these dilute nitrides.
2006-04-01
Gamma-rays and neutrinos from the pulsar wind nebulae
Energy Technology Data Exchange (ETDEWEB)
We construct the time-dependent radiation model for the pulsar wind nebulae (PWNe), assuming that leptons are accelerated in resonant scattering with heavy nuclei, which are injected into the nebula by the pulsar. The equilibrium spectra of these particles inside the nebula are calculated taking into account their radiation and adiabatic energy losses. The spectra of {gamma}-rays produced by these particles are compared with the observations of the PWNe emitting TeV {gamma}-rays and predictions are made for the expected {gamma}-ray fluxes from other PWNe. Expected neutrino fluxes and neutrino event rates in a 1 km{sup 2} neutrino detector from these nebulae are also calculated. It is concluded that only the Crab Nebula can produce a detectable neutrino event rate in the 1 km{sup 2} neutrino detector. Other PWNe can emit TeV {gamma}-rays on the level of a few percent of that observed from the Crab Nebula.
2005-08-01
Predictive maintenance plant assessment
Energy Technology Data Exchange (ETDEWEB)
Many electric power utilities are currently employing machine condition monitoring technologies as a means of reducing forced outages and controlling repair costs. These condition monitoring technologies are a set of {open_quotes}tools{close_quotes} to help maintenance and operations personnel identify and repair machinery problems before catastrophic failure occurs. In this way, the analysis of this data becomes a vital link in the daily operation of the plant. Machinery vibration analysis, machinery balancing and alignment, motor current testing, periodic thermography surveys, analysis of lubrication oil samples, performance monitoring, chemistry monitoring, ultrasonic leak detection surveys, and non-destructive inspections are some of the technologies available to perform this condition monitoring. However, even for a small or medium size plant, the sheer volume of data provided by applying all or some of these technologies can be staggering, not to mention the ...
1996-07-01
Energy Technology Data Exchange (ETDEWEB)
PETROBRAS/TRANSPETRO Pipelines and Terminals has 500 regular employees and 5.064 out sourced workers in its Southeast Division. The out sourced employees work through 125 contracts involving a wide range of activities such as maintenance, operational, pipeline launching , engineering, administrative and auxiliary services. Among these workers, 200 people are subjected to benzene occupational exposure, which might be present in the products we transport in our pipelines. Benzene is recognized as a carcinogen according to ACGIH and Brazilian Ministry of Labour regulation NR- 15. Exposure to benzene in an uncontrolled way, be it chronic or sharp, may affect the worker's health such as: hematological alterations, neoplasys, neurobehavior alterations. Our program PPEOB (acronym in Portuguese for benzene occupational exposure prevention program) involved the work force and fosters health by anticipation, recognition, evaluation and control of the situations that may result in ...
2004-07-01
Energy Technology Data Exchange (ETDEWEB)
PETROBRAS/TRANSPETRO Pipelines and Terminals have 500 regular employees and 5.064 out sourced workers in its Southeast Division. The out sourced employees work under 125 contracts involving a wide range of activities such as maintenance, pipeline operation, pipeline launching, engineering, administrative and auxiliary services. Among these workers, 1.200 peoples are subjected to occupational exposure, which may be present in the industrial process or in the products transported in our pipelines, e.g. industrial noise, sulfidric gas, toluene, xylene and benzene (recognized as a carcinogen according to ACGIH and Brazilian Ministry of Labour). Our PPRA (acronym in Portuguese for Occupational Exposure Prevention Program) involves the workforce and fosters health by anticipation, recognition, evaluation and control of the situations that may result in injuries. Further actions include the procurement of equipment for detection of these agents not ...
2005-07-01
International Nuclear Information System (INIS)
Seven types of shellfish were irradiated by gamma ray at doses of 0, 3 and 6 kGy. Pulse photo-stimulated luminescence (PPSL) and thermoluminescence (TL) methods were employed to detect the radiation treatment. The screening of irradiation was carried out by the PPSL method followed by identification using the TL technique. Most of the irradiated shellfish were screened out correctly and only a few showed photon counts a bit higher than the lower threshold value by much lower than the upper threshold value. The TL method was employed using minerals isolated from all the control and irradiated shellfish samples by density gradient treatment. Three parameters, integrated intensities of first glow curves (TL1), ratios of first to that of second glow curves (TL1/TL2), and the shapes of maxima of first glow curves, were utilized for the identification of gamma ray treatment of shellfish. (author)
Retrospective individual dosimetry using luminescence and EPR after radiation accidents
International Nuclear Information System (INIS)
In areas where radiation dose monitoring has not been performed, it is essential to use material available in the environment be able to rapidly assess doses to individuals for immediate emergency medical care or for general estimation of the radiological consequences. It was shown that certain types of telephone cards containing microchips have the potential to be used as individual radiation dosimeters in emergency situations to detect doses over 250 mGy by luminescence measurements. In order to understand the dosimetric properties of chip cards, the components obtained from INFINIEON Company at various stages of production were used for luminescence measurements. It is found that the protecting layer used above the chips so called 'globe top' is the main source of radiation induced signal in chip cards. The globe top produced by INFINIEON at that stage is found to contain SiO2 and Epoxy. In order to ...
Microclimatic conditions at the external surface of building envelopes
Energy Technology Data Exchange (ETDEWEB)
The project is described, the motivation for the research and the microclimate is defined in relation to both building physics research and applications. Air temperatur, air humidity, solar radiation and air velocity are briefly considered, whilst driving rain and long-wave radiation are described in more detail. Convective heat transfer and surface coefficients are discussed, although they are not microclimatic factors, merely resulting from combinations of such factors. They are included as they are important in relation to transfer of heat and moisture at the surface of the building envelope. Driving rain measurement is the main area of interest, including development of measurement equipment. Long-wave irradiation is measured and compared with empirical formulae from the literature. Window convection heat transfer is another main area of interest. Nocturnal convective heat transfer from a double pane glazing is studied ...
1998-12-31
International Nuclear Information System (INIS)
The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product measurement in the dosimetry ...
Laser eye protection. Interim report, July 1989-January 1990
Energy Technology Data Exchange (ETDEWEB)
Laser applications have proliferated in recent years and, as to be expected, their presence is no longer confined to the laboratory or places where access to their radiation can be easily controlled. One obvious application where this is so is in military operations where various devices such as laser range finders, target designators, and secure communications equipment elevate the risk of exposure, specifically eye exposure, to unacceptable levels. Although the need for eye protection in the laboratory and other controlled areas has been appreciated since the invention of the laser, the use of lasers in circumstances where safety or the risk of temporary loss of vision, which can not always be ensured by administrative procedures, has made adequate eye protection essential. It is the critical nature of many military operations that has driven the search for eye protection against both nuclear and laser radiation. At the ...
1990-01-01
Feasibility study on production of Co-60 in PHWR
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study is to analyze the safeties and the economics for Co-60 production from Wolsung PHWR and to verify the feasibility on the manufacturing of the final Co-60 source for industrial irradiation. The feasibility of reactor conversion was carried out with KEPCO collaboration. Through the site survey on the experience of Gentililly-2 in Canada, a feasibility of plant conversion, changes in design, equipment and tools for Co-60 production was verified. It was estimated that the reactor conversion would not impose adverse impact on plant safety. For the encapsulation of radiation source and storage of the final products, a modification of concrete hot cell at KAERI was primary concerns. The installation and improvement of facilities are needed to avoid cross contamination and extra radiation exposure. Main items for these are pressure gauge, separated HEPA filter the ceiling separation, extra-shielding and ...
2000-05-01
Environmental data for sites in the National Solar Data Network
Energy Technology Data Exchange (ETDEWEB)
The environmental data for the NSDN are presented in the form of tables for each solar site. The solar sites are grouped into 12 zones, each of which consists of several adjacent states. The solar energy sites are in alphabetical sequence within each zone. The tables provide available meteorological data for reporting sites in the NSDN as follows: Insolation - the insolation table presents the total, diffuse, direct, maximum, and extra-terrestrial radiation for the solar site. It also shows the ratio of total extra-terrestrial radiation, as a percent. Temperature - the temperature table gives the average, daytime, nightime, maximum, minimum and inlet-water temperatures for the solar site. Additional tables are presented for some of these NSDN sites, supplying either wind or relative humidity data, or both. Wind - all of the passive and some of the active solar sites are equipped with wind sensors. These provide information ...
1980-12-01
Real-time monitoring of dosimetry and image quality during digital radiology examinations
International Nuclear Information System (INIS)
Objective: To explore the feasibility of real-time monitoring exposure dose and image quality by using the data stored in the DICOM image archive of direct digital radiography system. Methods: Model TO. 16 was exposed, the current increased gradually from 0.5 to 125 mAs. The displayed number of model A( diameter 11.1 mm), D (diameter 4.0 mm) and J( diameter 0.7 mm) were recorded, and the detect factors (H_T) was also calculated. Images were sent to workstation before the end of DR examination. An automatic procedure was implemented to extract dose data and exposure parameters from the DICOM header file. Maximum, minimum and 3rd quartile values were preinstalled. Mean values exceeding the threshold trigger alarm signal to guide radiologist to explore the cause. Results: When the current of point A was less than 10 mAs and the current of point D and J were less than 16 mAs, the detect factor (H_T) increased with the rise of current. While point A ...
2009-12-01
Energy Technology Data Exchange (ETDEWEB)
Doubly-excited 2s{sup -1}2p{sup -1}3pnp autoionizing resonance series of Ne atom as well as autoionizing resonances in the 2s region of Na and Mg atoms have been studied with monochromatized synchrotron radiation. Use of charge-separated photoion-yield method allowed us to detect these weak resonances in a clarified way in the yield curves of doubly-charged ions. The observed resonance states have been interpreted with the help of MCDF calculations, and the decay processes of these resonance states are discussed briefly.
2007-03-01
International Nuclear Information System (INIS)
Doubly-excited 2s-12p-13pnp autoionizing resonance series of Ne atom as well as autoionizing resonances in the 2s region of Na and Mg atoms have been studied with monochromatized synchrotron radiation. Use of charge-separated photoion-yield method allowed us to detect these weak resonances in a clarified way in the yield curves of doubly-charged ions. The observed resonance states have been interpreted with the help of MCDF calculations, and the decay processes of these resonance states are discussed briefly.
2007-03-01
Nuclear borehole logging using lithium detector assemblies
International Nuclear Information System (INIS)
A method and apparatus for nuclear borehole logging, and in particular, neutron porosity logging, uses a neutron source, and a pair of spaced lithium detectors, preferably Li"6I crystal or Li"6 doped glass, to detect neutrons emitted from a borehole formation being logged. The spectrum developed by the lithium detectors is processed to remove the gamma ray background radiation and the hydrogen absorption peak, thus allowing a more accurate neutron count. A Gaussian curve is fitted to the neutron peak of the spectrum, the curve eliminating the hydrogen absorption peak. The area under this Gaussian curve represents the neutron count. (author).
1991-11-01
Multielement analysis of air samples
International Nuclear Information System (INIS)
Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A "2"3"8Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed. (author).
1981-01-01
International Nuclear Information System (INIS)
With a computerized curve fitting method the trapping parameters of TLD-100 chips were calculated after #alpha#-, #beta#- and #gamma#-irradiation. The absorption of radiation produces an additional glow peak at 250 deg C, and the dominant one arises at 280 deg C. After the analysis of the glow curves only a little LET-dependence of the trap depths and that of the half widths was detected. The charge densities after irradiation before heating of the taps responsible for the high temperature glow peaks (T>240 deg C) show a LET-dependence. (author).
1985-10-22
Gamma Radiation Detectors of the TA-55 Waste Line Monitoring System
Energy Technology Data Exchange (ETDEWEB)
This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.
1999-06-01
Energy Technology Data Exchange (ETDEWEB)
In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the {sup 137}Cs-source with 10.4 GBq and {sup 60}Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form {sup 137} Cs 1173.23 and 1332.51 keV{sup 60} Co sources, and 14 peaks of {sup 134}Cs and {sup 154}Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that the detection ...
2003-10-01
International Nuclear Information System (INIS)
In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the "1"3"7Cs-source with 10.4 GBq and "6"0Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form "1"3"7 Cs 1173.23 and 1332.51 keV"6"0 Co sources, and 14 peaks of "1"3"4Cs and "1"5"4Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that the detection efficiency of gamma ...
2003-10-01
Quality control in medical radiology using T.L.D
Energy Technology Data Exchange (ETDEWEB)
In this work tests of quality control in beams of X rays have been carried out, at diagnostic level, of two radiological services equipments of Brazilian hospitals (Aracaju, SE). We obtained the air kerma and kerma rate values, the beams efficiency, the coherence between the luminous fields and the referring fields of irradiation and half-value layer to each equipment and set of parameters. The measures of direct form have been obtained using two ionization chambers, one cylindrical and another one with parallel plates. An optional method for accomplishment some of the tests were carried out with CaSO{sub 4}:Dy + Teflon thermoluminescent dosimeters. The values of air kerma were evaluated for three tube voltage, 40, 60 and 81 kV at 1.0 m from the focus of the equipments. For each one of the voltages three distinct current values were chosen besides a fixed value of exposition time. The results showed that the values of air ...
2006-07-01
Energy Technology Data Exchange (ETDEWEB)
As a central supervision authority the National Electrical Safety Board (Elsaekerhetsverket) has the main responsibility for the safety of high voltage power lines and other power electric equipment. It is therefore also responsible for questions concerning the effects of power frequency magnetic fields on the environment. According to the rules it is not allowed to draw overhead power lines with a voltage exceeding 1000 V above buildings. Their minimum distance to buildings must not be below 5 m. For regions comprised by rural development plans the directions prescribe a minimum distance of 10 m between buildings and high voltage transmission lines with a voltage of 55 kV or more. The publication of two large epidemiological studies about exposure to magnetic fields and cancer in Sweden in autumn 1992 has brought magnetic fields problems to general notice again. A statement on health risks form electromagnetic fields was issued by SSI in January 1993. SSI and ...
1993-06-01
Energy Technology Data Exchange (ETDEWEB)
Changes in the phosphate metabolism of the transplanted SCCVII (squamous cell carcinoma VII) tumor were studied before and after irradiation using in vivo [sup 31]P-magnetic resonance spectroscopy (MRS). Phosphocreatine (PCr), [gamma]-, [alpha]-, [beta]-ATP, inorganic phosphate (Pi), phosphomonoester (PME), and phosphodiester (PDE) were detected in [sup 31]P-MR spectra of tumor tissues. The curve fitting method was employed for calculating each peak of [sup 31]P-MR spectra (PCr, [beta]-ATP, Pi, PME, PDE). The values of PCr, PCr/Pi, [beta]-ATP/Pi and pH decreased in proportion to the growth of tumor, whereas that of Pi, PME and PDE increased. But the changes of [beta]-ATP were minimal in degree. Based on the fact that the ratio of PCr/Pi highly correlated with tumor volume and showed the most remarkable change among various parameters, it might be the useful index for the tumor growth. Because the phospholipid metabolite PME was detected in the ...
1992-03-01
Modeling of Fission Neutrons as a Signature for Detection of Highly Enriched Uranium
Energy Technology Data Exchange (ETDEWEB)
We present the results of modeling intended to evaluate the feasibility of using neutrons from induced fission in highly enriched uranium (HEU) as a means of detecting clandestine HEU, even when it is embedded in absorbing surroundings, such as commercial cargo. We characterized radiation from induced fission in HEU, which consisted of delayed neutrons at all energies and prompt neutrons at energies above a threshold. We found that for the candidate detector and for the conditions we considered, a distinctive HEU signature should be detectable, given sufficient detector size, and should be robust over a range of cargo content. In the modeled scenario, an intense neutron source was used to induce fissions in a spherical shell of HEU. To absorb, scatter, and moderate the neutrons, we place one layer of simulated cargo between the source and target and an identical layer between the target and detector. The resulting neutrons ...
2004-03-09
Energy Technology Data Exchange (ETDEWEB)
Marketing of minimally processed vegetables (MPV) are gaining impetus due to its convenience, freshness and apparent health effect. However, minimal processing does not reduce pathogenic microorganisms to safe levels. Food irradiation is used to extend the shelf life and to inactivate food-borne pathogens. In combination with minimal processing it could improve safety and quality of MPV. A microbiological screening method based on the use of direct epifluorescent filter technique (DEFT) and aerobic plate count (APC) has been established for the detection of irradiated foodstuffs. The aim of this study was to evaluate the applicability of this technique in detecting MPV irradiation. Samples from retail markets were irradiated with 0.5 and 1.0 kGy using a {sup 60}Co facility. In general, with a dose increment, DEFT counts remained similar independent of the irradiation while APC counts decreased gradually. The difference of the two counts ...
2009-07-15
A superconducting solenoidal spectrometer for a balloon-borne experiment
Energy Technology Data Exchange (ETDEWEB)
The BESS detector is a new type of balloon-borne spectrometer which utilizes various technologies recently developed for collider experiments. The principal scientific objectives include a measurement of cosmic-ray antiproton spectrum, search for anti-nuclei in cosmic radiation, and precise measurements of cosmic-ray primaries. A thin superconducting solenoidal coil produces a uniform magnetic field of 1 T. Cylindrical drift chambers are located inside and outside the coil and perform continuous tracking. The momentum resolution is 0.5% at 1 GeV/c. i.e., the maximum detectable rigidity is 200 GV. Scintillation counter hodoscopes, placed above and below the solenoid, provide timing and dE/dx measurements and trigger generation. The timing resolution is 80 ps/counter. This cylindrical configuration achieves a large geometrical acceptance of 0.35 m{sup 2} sr which is essential to detect rare cosmic-ray particles. In order to ...
2000-03-21
Status of the WAND (Waste Assay for Nonradioactive Disposal) project as of July 1997
Energy Technology Data Exchange (ETDEWEB)
The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform the data analysis. WAND system minimum detectable activities (MDAs) for point sources ...
1998-03-01
Boron-Lined Multichamber and Conventional Neutron Proportional Counter Tests
Energy Technology Data Exchange (ETDEWEB)
Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. These technologies are: 1) Boron ...
2010-09-07
Molecular events involved in ionizing radiation induced skin carcinogenesis
International Nuclear Information System (INIS)
The process of mouse skin tumor formation is subdivided into three operational stages. These stages include initiation, promotion and progression. Ionizing radiation has been found to be a weak initiating agent in the production of malignant squamous cell carcinomas, a complete carcinogen and an agent effective in causing tumor progression. Four skin tumor histologies have been seen with ionizing radiation: benign papillomas, squamous (SCC) and basal (BCC) cell carcinomas and fibrosarcomas. Distinct non-ras transforming genes have been detected in radiation initiated SCCs. A benign papilloma cell line (308) was used as a model system to study ionizing radiation induced progression. A variant 308 cell line (308 10 Gy 5) derived by irradiation of the parental 308 cell has been characterized. The 308 10 Gy 5 cells unlike the parental 308 cells from malignant tumors in athymic nude mice ...
Energy Technology Data Exchange (ETDEWEB)
Investigated here were the effects of microwave (MW) radiation (2450-MHz, continuous-wave, mean specific absorption rate of 103.5 + or - 4.2 W/kg) and convention heating on the nonphosphorylating oxidative metabolism of human peripheral mononuclear leukocytes (96% lymphocytes, 4% monocytes) at 37 C. Metabolic activity, determined by chemiluminescence (CL) of cells challenged with luminol (5-aminO-2, 3-dihydro-1, 4-phthalazinedione) linked to bovine serum albumin, was detected with a brightness photomer. A significant stimulation after after MW exposure (p < 0.005) over total CL of matched 37 C-incubator controls was observed. A similar degree of stimulation, compared to incubator controls, was also detected after sham treatment. No significant difference existed between changes in total CL or stimulation indices of the MW and sham-exposed groups. Exposure to MW radiation, under normothermic (37 + or ...
1986-01-01
International Nuclear Information System (INIS)
The effect of the #+-# 0.75 T external magnetic field on the K_#alpha#_1, K_#alpha#_2, K_#beta#_'_1 and K_#beta#_'_2 x-ray production cross sections and radiative vacancy transfer probabilities from K-shell to L2 and L3 subshells and M-shell for ferromagnetic Nd, Gd and Dy and paramagnetic Eu and Ho have been investigated, using the 59.5 keV incident photons. K-shell fluorescence yields and K x-ray intensity ratios for these elements have been determined in the external magnetic field also. The K x-rays from different targets were detected using a high-resolution Si(Li) semiconductor detector. For B = 0, the present experimental results were compared with the experimental and theoretical data in the literature. The results show that K-shell fluorescence parameters such as photoionization cross section, fluorescence yield, radiation rates, vacancy transfer probabilities and spectral linewidth can change owing to the applied ...
2006-06-19
Energy Technology Data Exchange (ETDEWEB)
We report a patient who developed occlusion of the intracranial major arteries induced by radiation therapy for craniopharyngioma. The patient, a 9-year-old boy, presented with deterioration of vision, nausea and vomiting. He underwent a right ventriculo-peritoneal shunt operation, and the tumor was partially removed. Postoperatively, he received focal radiation therapy with total of 60 Gy. Preoperative cerebral angiography, cerebral vessels had no sigh of occlusive lesion or stenosis. One year after irradiation, he started to have repeated cerebral ischemic attacks. But no regrowth of the tumor was detected on CT scans. Two years and 8 months after irradiation, he suddenly had right hemiparesis. Cerebral angiography revealed severe stenosis of the right anterior cerebral artery (precommunicating segment), middle cerebral artery (horizontal portion) and terminal portion of the right carotid artery. Left carotid angiography ...
1994-10-01
International Nuclear Information System (INIS)
We report a patient who developed occlusion of the intracranial major arteries induced by radiation therapy for craniopharyngioma. The patient, a 9-year-old boy, presented with deterioration of vision, nausea and vomiting. He underwent a right ventriculo-peritoneal shunt operation, and the tumor was partially removed. Postoperatively, he received focal radiation therapy with total of 60 Gy. Preoperative cerebral angiography, cerebral vessels had no sigh of occlusive lesion or stenosis. One year after irradiation, he started to have repeated cerebral ischemic attacks. But no regrowth of the tumor was detected on CT scans. Two years and 8 months after irradiation, he suddenly had right hemiparesis. Cerebral angiography revealed severe stenosis of the right anterior cerebral artery (precommunicating segment), middle cerebral artery (horizontal portion) and terminal portion of the right carotid artery. Left carotid angiography ...
1994-01-01
International Nuclear Information System (INIS)
The radiographic appearance of Ewing's sarcoma was studied retrospectively in 22 patients who survived 5 years or longer after diagnosis and treatment. Expected changes from treatment, including regression of the extraosseous soft tissue mass, periostitis, and reconstitution of the cortex, occurred in all patients. Local recurrence occurred in one patient 10 years after complete remission whereas secondary osteosarcoma occurred more than 5 years after complete remission in two other cases. Both recurrent and secondary tumors presented as new lytic foci at the site of the original primary lesion. Lytic changes from radiation (radiation osteitis) may develop more than 2 years after treatment and in this sample; such findings were widely distributed in the radiation port. The authors conclude that bone remodeling and postradiation changes occur slowly over 2 years after treatment, and that any localized lysis at the primary ...
Development of a phoswich detector to detect neutrons in the charged-particle mixed field
Energy Technology Data Exchange (ETDEWEB)
Manned-space missions bring an exposure due to corpuscular radiations of which nature is quite different from what we encounter in the ground environment. In the space environment, many secondaries are produced through interactions of cosmic ray primaries with the spacecraft wall and other surrounding materials. Among this large variety of radiation components in the space, the contribution of neutrons to the radiation exposure of astronauts has remained to be studied. Up to today, efforts to measure neutron dose equivalent have been made using passive detector systems. Considering uncertainties involved in current measurements and estimations of high energy neutrons, and their increasing importance for future manned missions, it is necessary to measure neutron spectrum in the spacecraft under realistic conditions. The neutron spectra have never been measured on board a spacecraft, because the neutron measurement requires ...
1997-07-01
International Nuclear Information System (INIS)
... organizations irradiation radiation doses radiation effects RADIATIONS.
1982-01-01
Radiation technology of wood-plastic composite materials
International Nuclear Information System (INIS)
... radiation effects RADIATIONS. WOOD-PLASTIC COMPOSITES.
1981-10-02
Radiation chloration sulfochloration and sulfooxidation of organic compounds
International Nuclear Information System (INIS)
... halogenation ionizing radiations kinetics radiations reaction kinetics
Energy Technology Data Exchange (ETDEWEB)
''Intelligent Extruder'' described in this report is a software system and associated support services for monitoring and control of compounding extruders to improve material quality, reduce waste and energy use, with minimal addition of new sensors or changes to the factory floor system components. Emphasis is on process improvements to the mixing, melting and de-volatilization of base resins, fillers, pigments, fire retardants and other additives in the :finishing'' stage of high value added engineering polymer materials. While GE Plastics materials were used for experimental studies throughout the program, the concepts and principles are broadly applicable to other manufacturers materials. The project involved a joint collaboration among GE Global Research, GE Industrial Systems and Coperion Werner & Pleiderer, USA, a major manufacturer of compounding equipment. Scope of the program included development ...
2003-04-24
Energy Technology Data Exchange (ETDEWEB)
The R and D were carried out of a detecting system for measurement of data on the bottom of geothermal well, data transmission and signal processing, and an analysis system for well drilling trajectory control and well assessment while geothermal well drilling based on the data obtained by the detecting system. The paper reported the results of the technology development in fiscal 1996. In the development of the detecting system, improvement/design were conducted on a mud pulse generator constituting sonde, well bottom signal processing equipment, mode switch and inclined information sensor, and the system equivalent to the actual one was manufactured to conduct a running test at high temperature/pressure. Moreover, a test to confirm heat resistance of electronic parts was made for further improvement in heat resistance of the sonde, in order to obtain the data. In the development of an analysis system, ...
1997-03-01
International Nuclear Information System (INIS)
The objective of this study was to explore the role of three-dimensional (3-D) rotational angiography (RA) of the inferior vena cava (IVC; 3-D CV) before filter retrieval and its impact on treatment planning compared with standard anteroposterior cavography (sCV). Thirty patients underwent sCV and 3-D CV before IVC filter retrieval. Parameters assessed were: projection of filter arms or legs beyond the caval lumen, thrombus burden within the filter and IVC, and orientation of the filter within IVC. Skin and effective radiation doses were calculated. Statistical analysis was performed using paired Student t test and nonparametric McNemar's test. Standard anteroposterior cavography detected 49 filter arms or legs projecting beyond the caval lumen in 25 patients. Three-dimensional CV demonstrated 89 filter arms or legs projecting beyond the caval lumen in 28 patients. Twenty-two patients had additional filter arms or legs projecting beyond the ...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
The optically stimulated luminescence (OSL) results a highly appropriate dosimetric technique for readings of absorbed radiation 'in alive' and 'in situ', as well as in real time. The CVD diamond on the other hand presents excellent qualities like radiation reader thanks to its reproducibility, radiation resistance, biocompatibility and non toxicity. The present work studies the answer of two diamond films pure and polluted with nitrogen (750 ppm) grown by the Chemical Vapor Deposition method (CVD) on silicon substrate (001) irradiated with beta (Sr-90) in the 0.833-100 Gy interval. The optical stimulation was carried out by 40 seconds with infrared laser (830 nm, 0.36 W/cm{sup 2}) and the filter BG-39 (300-600 nm) coupled the PM. The intensity and the decay of the hyperbolic type of the LOE curves were similar in both samples, for the non doped diamond were observed trapping states in ...
2006-07-01
International Nuclear Information System (INIS)
Purpose: Patients with ataxia-telangiectasia (A-T) show greatly increased radiation sensitivity and cancer predisposition. Family studies imply that the otherwise clinically silent heterozygotes of this autosomal recessive disease run a 3.5 to 3.8 higher risk of developing cancer. In vitro studies suggest moderately increased cellular radiation sensitivity of A-T carriers. They may also show elevated clinical radiosensitivity. We retrospectively examined patients who presented with severe adverse reactions during or after standard radiation treatment for mutations in the gene responsible for A-T, ATM, considering a potential means of future identification of radiosensitive individuals prospectively to adjust dosage schedules. Material and Methods: We selected 20 cancer patients (breast, 11; rectum, 2; ENT, 2; bladder, 1; prostate, 1; anus, 1; astrocytoma, 1; Hodgkins lymphoma, 1) with Grade 3 to 4 (RTOG) acute and/or late ...
1999-07-15
International Nuclear Information System (INIS)
Naturally occurring radionuclides are present in most material. The most common naturally occurring radionuclides in material are those of the uranium and thorium series and potassium-40. This material is commonly referred to as Naturally Occurring Radioactive Material (NORM). In some material the levels of naturally occurring radionuclides are significantly higher, to the extent that regulatory control may be required for radiation protection purposes. Regulation of NORM presents a range of new challenges for both regulators and operators. Unlike more traditional industries dealing with radionuclides, NORM industries have generally not had any radiological oversight and, for example, are not equipped for radiological monitoring. Some consumer goods containing NORM, which have not traditionally been considered as a radiological problem (such as some fertilizers), may require regulation and this may have social and economic consequences. The ...
2002-09-23
Chemical, sensory and microbiological changes of gamma irradiated coconut cream powder
Energy Technology Data Exchange (ETDEWEB)
A study was carried out to determine optimum decontamination dose for a locally manufactured coconut cream powder. Samples were gamma irradiated (0-15 kGy) and ageing process was achieved using GEER oven at 60 deg. C for 7 days, which is equivalent to one-year storage at room temperature. Iodine value (IV), ranging from 4.8 to 6.4, was not affected by radiation doses and storage, however peroxide value and thiobarbituric acid (TBA) generally increased with radiation doses. In most samples, peroxide value (meq/kg) reduced after storage, whilst the TBA (mg malonaldehyde/kg), indicator for product quality, slightly increased. The sensory evaluation conducted using 25 taste panellists indicated that scores on odour, creamy taste and overall acceptance for all irradiated samples at more than 5 kGy were significantly lower (P<0.05) than the control. However, the panellists could not detect any significant differences among ...
2007-11-15
Recent developments and applications for the University of Texas thermal neutron imaging facility
Energy Technology Data Exchange (ETDEWEB)
The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system resolution have hot been determined. The TNIF is currently being revamped to begin work with the ...
2001-07-01
Induction and use of sex linked lethal mutations in the pink bollworm
International Nuclear Information System (INIS)
The sterile insect release technique can often be improved by removal of females before release. Rearing efficiencies can also be increased if removal of the females occurs at early developmental stages. In order to begin to develop genetic sexing strains for the pink bollworm, Pectinophora gossypiella (Saunders), it was necessary to determine the best dosage of radiation for induction of viable sex linked recessive lethal mutations and to see if stocks containing induced sex linked lethals could be maintained in culture. Sex linked recessive lethal mutations can be detected by distorted sex ratios in the progeny of treated adults. However, in the pink bollworm, highly distorted sex ratios are common even in the absence of induced mutations. Therefore, a visible sex linked trait, purple eye, was used as a marker for the untreated X-chromosomes in crosses. Thus, the presence of a recessive sex linked lethal mutation induced by the ...
1987-11-16
Supply of medium and small hydropower equipment
Energy Technology Data Exchange (ETDEWEB)
This paper presents a brief account of Lingling Hydroelectric Power Equipment General Works, the capacity of equipment production, the organization body, the quality assurance system and supervision of government department on its product quality.
1995-07-01
30 CFR 77.1607 - Loading and haulage equipment; operation.
...2009-07-01 2009-07-01 false Loading and haulage equipment; operation. 77.1607 Section 77.1607...Loading and Haulage § 77.1607 Loading and haulage equipment; operation. (a) Vehicles shall follow...
2009-07-01
30 CFR 77.1605 - Loading and haulage equipment; installations.
...2010-07-01 2010-07-01 false Loading and haulage equipment; installations. 77.1605 Section 77.1605...Loading and Haulage § 77.1605 Loading and haulage equipment; installations. (a) Cab windows shall...
2010-07-01
30 CFR 75.1405-1 - Automatic couplers, haulage equipment.
... 2010-07-01 false Automatic couplers, haulage equipment. 75.1405-1 Section 75.1405-1 Mineral...Mantrips § 75.1405-1 Automatic couplers, haulage equipment. The requirement of § 75.1405 with...
2010-07-01
30 CFR 70.1900 - Exhaust Gas Monitoring.
...contribution of all diesel equipment on such section; (2) In the area of the section loading point if diesel haulage equipment is operated on the working section; (3) At a point inby the last piece of diesel equipment on the...
2009-07-01
29 CFR 1926.800 - Underground construction.
...competent person shall inspect haulage equipment before each shift. (ii...used. (2) Powered mobile haulage equipment shall have suitable means of... (3)(i) Power mobile haulage equipment, including trains, shall...
2010-07-01
The Two-Column Aerosol Project (TCAP) Science Plan
Energy Technology Data Exchange (ETDEWEB)
The Two-Column Aerosol Project (TCAP) field campaign will provide a detailed set of observations with which to (1) perform radiative and cloud condensation nuclei (CCN) closure studies, (2) evaluate a new retrieval algorithm for aerosol optical depth (AOD) in the presence of clouds using passive remote sensing, (3) extend a previously developed technique to investigate aerosol indirect effects, and (4) evaluate the performance of a detailed regional-scale model and a more parameterized global-scale model in simulating particle activation and AOD associated with the aging of anthropogenic aerosols. To meet these science objectives, the Atmospheric Radiation Measurement (ARM) Climate Research Facility will deploy the ARM Mobile Facility (AMF) and the Mobile Aerosol Observing System (MAOS) on Cape Cod, Massachusetts, for a 12-month period starting in the summer of 2012 in order to quantify aerosol properties, radiation, and ...
2011-07-27
Repair shops and back-up facilities of the Belchatow mine
Energy Technology Data Exchange (ETDEWEB)
Repair and maintenance for equipment used in the Belchatow brown coal mine and organizational models of repair services in the mine are discussed. Maintenance of earthmoving equipment, spreaders, bucket wheel excavators, loaders and other coal handling equipment, belt conveyors and drive systems for belt conveyors is discussed. Repair shops in the mine also manufacture about 35% of spare parts and elements for equipment used in the mine. Reliability of mining equipment, repairs and repair capacity of the shops are discussed. Organizational models of repair services, equipment used by these services and repair personnel are described. Effects of repair services on operation of the mine are evaluated.
1984-01-01
The magnetic resonance and its agro-industry applications; a review
International Nuclear Information System (INIS)
The electromagnetic properties that present hydrogen and other nucleus of agro-alimentary products, have allowed widely use of magnetic resonance (MR) to study the composition and internal structure of these biological materials in a micro and macroscopic scale, in a nondestructive way. In this paper the physical principles, basic equipment to measure the MR signals and the MR imaging of any biological sample, are explained. It is also shown a review of the main agro-alimentary applications, emphasizing in the use of this principle to examine the internal quality of fruits and vegetables. In these products, the MR has been used to detect and follow the evolution of different factors that determine the internal quality after harvesting, during storage and after post harvesting processes. The main studies that have been conducted with MR in harvested products are about physiological disorders that take place during storage and conservation of ...
Systems Analysis of Safeguards Effectiveness in a Uranium Conversion Facility
Energy Technology Data Exchange (ETDEWEB)
The U.S. Department of Energy (DOE) is interested in developing tools and methods for potential U.S. use in designing and evaluating safeguards systems. For this goal several DOE National Laboratories are defining the characteristics of typical facilities of several size scales, and the safeguards measures and instrumentation that could be applied. Lawrence Livermore National Laboratory is providing systems modeling and analysis of facility and safeguards operations, diversion path generation, and safeguards system effectiveness. The constituent elements of diversion scenarios are structured using directed graphs (digraphs) and fault trees. Safeguards indicator probabilities are based on sampling statistics and/or measurement accuracies. Scenarios are ranked based on value and quantity of material removed and the estimated probability of non-detection. Significant scenarios, especially those involving timeliness or randomly varying order of events, are transferred ...
2004-06-16
International Nuclear Information System (INIS)
The Nuclear Safety Commission acknowledged the policy of the Agency of Natural Resources and Energy to cope with these important matters on August 8, 1984. The main contents of the investigation and deliberation were as follows, As to the prevention of the occurrence of fires, the prevention of the leak and spread of inflammable liquid and gas, the installation of protective relays and so on, the use of incombustible materials and aseismatic design and the installation of lightning arresters. As to the detection of fires and fire fighting, the proper selection and arrangement of fire detectors and extinguishers, the extinguishers which do not harm the safety function of structures and equipment, and the extinguishers which are not affected by natural phenomena. As to the reduction of the effect of fires, the proper installation of fire walls and extinguishers, and the high temperature shut off of nuclear reactors which is never hampered by any ...
1985-01-01
The main LHC superconducting magnets (dipoles and quadrupoles) use Rutherford type cables, stabilized electrically and thermally with copper profiles. The portions of cables are connected to each other by a soft soldering technique (Sn96Ag4) with an overlapping length corresponding to one pitch of the superconducting strands. The splice constitutes a "composite" structure with the interchanging layers of Sn96Ag4 and NbTi superconductor, located inside a Cu cage. In order to ensure a high level of reliability (failure probability not exceeding 10-8) for some 10000 connections in the LHC, a non-destructive technique to check the quantity of solder in the joint is foreseen. The technique is based on a gamma ray source (241Am) and the detection is position-sensitive in the transmission mode. Scintillating detectors of gamma rays are used and their accumulated length corresponds to the length of the radioactive source (120 mm). The method can be used in-situ, the ...
2004-01-01
Measurement of mud level interfaces: A tool for optimization of red mud washing at C.V.G. Bauxilum
Energy Technology Data Exchange (ETDEWEB)
For the expansion to 2.0 MTPY of the CVG Bauxilum alumina plant, the area of clarification and red mud washing was rearranged from four 2-thickener-5-washer trains to two 1-thickener-7-washer trains. As a result of this modification, the specific mud handling capacity of the existing tanks should be increased by almost 3-times. The time allowed for control actions was then significantly reduced, leading to the need of an on-line level detection system, in order to achieve a better and faster control of the operation. With this scope, it was developed and installed a new continuous mud level detector that gives the measurement of both mud and turbid zone levels in the tanks. The development of the new instrument started with an existing instrument for density measurements which was completely re-engineered in order to obtain the maximum readability in the densities founded along the full range of the tank height. Actually 28 tanks are equipped ...
1996-10-01
Energy Technology Data Exchange (ETDEWEB)
A 19.1 metre wind turbine blade was subjected to static tests. The purpose of the test series was to verify the abilities of different types of sensors to detect damage in wind turbine blades. Prior to each of the static test-series an artificial damage was made on the blade. The damage made for each test-series was surveyed during each series by acoustic emission, fiber optic micro bend displacement transducers and strain gauges. The propagation of the damage was determined by use of ultra sonic and X-ray surveillance during stops in the test series. By use of acoustic emission it was possible to measure damage propagation before the propagation was of visible size. By use of fiber optic micro bend displacement transducers and strain gauges it was possible to measure minor damage propagation. By use of both ultra sonic, and X-ray NDT-equipment it were possible to determine the size of propagated damage. (au)
2002-05-01
Expert overseer for mass spectrometer system
Energy Technology Data Exchange (ETDEWEB)
This patent describes an expert overseer for the operation and real-time management of a mass spectrometer and associated laboratory equipment. The overseer is a computer-based expert diagnostic system implemented on a computer separate from the dedicated computer used to control the mass spectrometer and produce the analysis results. An interface links the overseer to components of the mass spectrometer, components of the laboratory support system, and the dedicated control computer. Periodically, the overseer polls these devices and as well as itself. These data are fed into an expert portion of the system for real-time evaluation. A knowledge base used for the evaluation includes both heuristic rules and precise operation parameters. The overseer also compares current readings to a long-term database to detect any developing trends using a combination of statistical and heuristic rules to evaluate the results. The overseer has the capability ...
1991-06-18
Expert overseer for mass spectrometer system
International Nuclear Information System (INIS)
This patent describes an expert overseer for the operation and real-time management of a mass spectrometer and associated laboratory equipment. The overseer is a computer-based expert diagnostic system implemented on a computer separate from the dedicated computer used to control the mass spectrometer and produce the analysis results. An interface links the overseer to components of the mass spectrometer, components of the laboratory support system, and the dedicated control computer. Periodically, the overseer polls these devices and as well as itself. These data are fed into an expert portion of the system for real-time evaluation. A knowledge base used for the evaluation includes both heuristic rules and precise operation parameters. The overseer also compares current readings to a long-term database to detect any developing trends using a combination of statistical and heuristic rules to evaluate the results. The overseer has the capability ...
1989-04-04
Consequences of warm-up of a sector above 80K
There may be circumstances when a sector has to be partially or totally warmed-up to temperatures above 80 K, that is when thermal dilatation starts to play a role. Some equipment have been identify as presenting a risk, like the non-conform "plug-in" modules in the arcs. Because of motion induced by thermal dilatation, the electrical (ElQA) quality control may also have to be done again after cool-down. The main reason identified so far for partial warm-up is the required maintenance of the cooling towers and the cryogenics plants. There is also the request from the vacuum group to periodically warm-up the beam screen to temperatures in the 100 K region to release and pump-out the gas crysorbed on the surface of the beam screen. Observed and expected temperature conditions and statistics on failures of PIMs in sectors which have been warmed-up will be presented in this contribution. Methods to detect buckled PIMs will be described, as well as ...
2009-01-01
A New and Sound Technology for Biogas from Solid Waste and Biomass
International Nuclear Information System (INIS)
Organic waste, as a main constituent of municipal solid waste, has as well as solid biomass a high potential for biogas generation. Despite the importance of biogas generation from these materials, the availability of large-scale biogas processes lacks behind the demand. A newly developed double-stage solid-liquid biogas process, consisting of an open hydrolysis stage and a fixed-bed methane reactor, allows the biogas production from almost all biodegradable solid waste and renewable resources like maize, grass, sugar cane, etc. Furthermore, residues from industrial processes, like the glycerine waste water from biodiesel production, can also be converted into biogas successfully. Due to the strong separation of hydrolysis and methanation, the process is extremely stable. No malfunction has been detected so far. The open hydrolysis releases CO_2 and allows oxidation of sulfur. Consequently, the biogas has a high methane (>72%) and low H_2S concentration (<100 ...
2009-04-01
Imaging-based dust sensors: equipment and methods
Dust detection and control in real time, represent one of the most challenging problem in all those environments where fine and ultrafine airborne particulate solids products are present. The presence of such products can be linked to several factors, often directly related and influenced by the working-production actions performed. Independently from the causes generating dust, airborne contaminants are an occupational problem of increasing interest as they are related to a wide number of diseases. In particular, airborne dusts are well known to be associated with several classical occupational lung diseases, such as the pneumoconiosis, especially at high levels of exposure. Nowadays there is also an increasing interest in other dust related diseases, from the most serious as cancer and asthma, to those related with allergies or irritation and other illnesses, also occurring at lower levels of exposure. Among the different critical factors influencing health risk ...
2004-05-01
The Deep Space Network Progress Report 42-39 - NASA Technical ...
C. Learning Curve. The learning curve concept has long been recognized and ...... F4. TERMIA. S - STATION EQUIPMENT. V - VLBI VALIDATION EQUIPMENT ...
X-ray, Optical, and Radio Observations of SN 1999em and SN 1998S
Observations of the Type II-P (plateau) Supernova (SN) 1999em and Type IIn (narrow emission line) SN 1998S have enabled estimation of the profile of the SN ejecta, the structure of the circumstellar medium (CSM) established by the pre-SN stellar wind, and the nature of the shock interaction. SN 1999em is the first and only Type II-P detected at both X-ray and radio wavelengths. It is the least radio luminous and one of the least X-ray luminous SN ever detected (except for the unusual and very close SN 1987A). The Chandra X-ray data indicate non-radiative interaction of SN ejecta with a power-law density profile (rho \\propto r^{-n} with n ~ 7) with a pre-SN wind with a low mass loss rate of ~2 \\times 10^{-6} Msun/yr for a wind velocity of 10 km/sec, in close agreement with radio mass-loss rate estimates. The Chandra data show an unexpected, temporary rise in the 0.4--2.0 keV X-ray flux at ~100 days after explosion. SN ...
2001-01-01
Validating eddy current array probes for inspecting steam generator tubes
International Nuclear Information System (INIS)
A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. Methods are presented for ...
1997-11-16
Validating eddy current array probes for inspecting steam generator tubes
Energy Technology Data Exchange (ETDEWEB)
A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. Methods are presented for ...
1997-07-01
The influence of salt aerosol on alpha radiation detection by WIPP continuous air monitors
Energy Technology Data Exchange (ETDEWEB)
Alpha continuous air monitors (CAMs) will be used at the Waste Isolation Pilot Plant (WIPP) to measure airborne transuranic radioactivity that might be present in air exhaust or in work-place areas. WIPP CAMs are important to health and safety because they are used to alert workers to airborne radioactivity, to actuate air-effluent filtration systems, and to detect airborne radioactivity so that the radioactivity can be confined in a limited area. In 1993, the Environmental Evaluation Group (EEG) reported that CAM operational performance was affected by salt aerosol, and subsequently, the WIPP CAM design and usage were modified. In this report, operational data and current theories on aerosol collection were reviewed to determine CAM quantitative performance limitations. Since 1993, the overall CAM performance appears to have improved, but anomalous alpha spectra are present when sampling-filter salt deposits are at normal to high levels. This report shows that ...
1996-01-01
Reactivity differences of hydroxyl radicals and hydrated electrons in destructing azo dyes
International Nuclear Information System (INIS)
The high-energy radiation-induced degradation of an H-acid derivative azo dye, Apollofix-Red SF-28 (AR-28) was studied in aqueous solution by using pulse radiolysis with kinetic spectroscopic detection for transient measurements. Gamma radiolysis with UV-VIS spectroscopy and gradient ionpair HPLC separation with diode array detection were applied for following the destruction of AR-28 and measuring the products. The reactions of hydrated electron (e_a_q "-) and hydroxyl ("#centre dot#OH) radical were investigated separately. "#centre dot#OH reacts with the unsaturated bonds of the molecule. In the further reactions of the "#centre dot#OH adduct radicals, the AR-28 molecules partly reform with a slightly modified structure. The products formed in the first reaction of "#centre dot#OH and AR-28 molecules have also high reactivity towards the "#centre dot#OH radicals. For these reasons the efficiency of "#centre dot#OH ...
High resolution Computed Tomography in the study of temporal bone trauma
International Nuclear Information System (INIS)
Thirty-five patients with temporal bone fractures were examined; the fractures were sometimes associated with dislocation of the assicular chain caused by road fatalities. Computed Tomography (CT) was performed either because of the presence of clinical symptoms associated with trauma of the temporal bone, because of a hemotympanum discovered during a CT scan of the brain. Thirty-three fractures were detected: 19 longitudinal, 6 transverse, and 8 complex. An incudostapedial dislocation was also detected, together with a displacement of a stapedial prosthesis from the lenticular process of incus, and 3 incus-malleus dislocation associated with fractures. High resolution CT allows the precise definition of the course of the fractures, of the associated dislocation of the ossicular chain, and of facial nerve lesion, thus allowing a more accurate surgical intervention. In the examination of the temporal bone, high resolution CT is preferible to ...
1988-01-01
Energy Technology Data Exchange (ETDEWEB)
A new method is being developed to quickly screen for the human exposure potential to polycyclic aromatic hydrocarbons (PAHs) and organochlorines (OCs). The development involves two key elements: identifying suitable signals that represent intracellular changes that are specific to PAH and OC exposure, and constructing a device to guide the biological cell growth so that signals from individual cells are consistent and reproducible. We are completing the identification of suitable signals by using synchrotron radiation-based (SR) Fourier-transform infrared (FTIR) spectromicroscopy in the mid-infrared region (4000-400 cm-1). Distinct changes have been observed in the IR spectra after treatment of human cells in culture medium with PAHs and OCs. The potential use of this method for detecting exposure to PAHs and OCs has been tested and compared to a reverse transcription polymerase chain reaction (RT-PCR) assay that quantifies increased ...
1999-01-10
Automated method for determining location and magnitude of leaks inside a PWR containment
Energy Technology Data Exchange (ETDEWEB)
Thermal-hydraulics analysis can be used to determine location and magnitude of leaks inside a pressurized water reactor (PWR) containment, as required by plant technical specifications. The major advantage of this detection method is that it minimizes radiation exposure of maintenance personnel because most of the leak detection process is performed from the control room outside the containment. In addition, such a program allows for the elimination of pipe whip restraints and jet impingement shields, eliminating costs for maintenance of these supports and shields in older plants and lowering construction costs for new plants. Previously, only simple single-node containment models were used for determining leakage magnitude. This paper presents a more sophisticated multinode approach for determining the magnitude and location. The resulting sensitivities to leak can be programmed into the plant's computer system. ...
1986-01-01
Detection by cationized /sup 125/I-cytochrome C of proteoglycans (PG) transferred to nylon
Energy Technology Data Exchange (ETDEWEB)
Cytochrome c, labeled with /sup 125/I, has been used by us for staining glycosaminoglycans (GAG) separated by electrophoresis on cellulose acetate strips. As GAG between 1-10 ng could be quantified by autoradiography and densitometry, the reagent is approximately 100-fold more sensitive than currently used non-radiolabeled stains. The authors extend now the use of radiolabeled cytochrome c to the quantification of PG transblotted to solid supports subsequent to separation on polyacrylamine slab gels. Dot blotting used for exploring optimal conditions for detecting PG indicated that because of low background positively charged Nylon 66 was superior to nitrocellulose. Increasing the positive charge of the staining reagent by cationization decreased background radiation even further so that 1 ng PG could be seen readily after 5 hrs of autoradiography. Use of cationized /sup 125/I-cytochrome c has been made in detecting PG of ...
1986-05-01
In 2002 and again in 2003, an investigative journalist unit at ABC News transported a 6.8 kilogram metallic slug of depleted uranium (DU) via shipping container from Istanbul, Turkey to Brooklyn, NY and from Jakarta, Indonesia to Long Beach, CA. Targeted inspection of these shipping containers by Department of Homeland Security (DHS) personnel, included the use of gamma-ray imaging, portal monitors and hand-held radiation detectors, did not uncover the hidden DU. Monte Carlo analysis of the gamma-ray intensity and spectrum of a DU slug and one consisting of highly-enriched uranium (HEU) showed that DU was a proper surrogate for testing the ability of DHS to detect the illicit transport of HEU. Our analysis using MCNP-5 illustrated the ease of fully shielding an HEU sample to avoid detection. The assembly of an Improvised Nuclear Device (IND) -- a crude atomic bomb -- from sub-critical pieces of HEU metal was then examined ...
2007-04-01
The result of Alanine/ESR dosimetry at Wolsung unit 1
International Nuclear Information System (INIS)
It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate dose, two environmental correction factors, irradiation temperature and ...
2008-10-01
Technology development, evaluation, and application (TDEA) FY 1997 progress report
Energy Technology Data Exchange (ETDEWEB)
The public expects that the Los Alamos National Laboratory (LANL) will operate in a manner that prevents negative impacts to the environment and protects the safety and health of its employees and the public. To achieve this goal within budget, the Department of Energy (DOE) and LANL must develop new and improved environment, safety, and health (ES and H) technologies and implement innovative, more cost-effective ES and H approaches to operations. In FY95, the Environment, Safety, and Health (ESH) Division initiated a Technology Development, Evaluation, and Application (TDEA) program. The purpose of this unique program is to test and develop technologies that solve LANL ES and H problems and improve the safety of LANL operations. This progress report presents the results of 10 projects funded in FY97 by the TDEA Committee of the Environment, Safety, and Health Division. Products generated from the projects funded in FY97 included implementation of radiation worker ...
1998-05-01
Synchrotron resource of the Howard Hughes Medical Institute
Energy Technology Data Exchange (ETDEWEB)
The Synchrotron Resource of the Howard Hughes Medical Institute will be dedicated to structural analyses of biological macromolecules, primarily through crystallography. This facility is under construction at the X4 port of the National Synchrotron Light Source at Brookhaven National Laboratory, and it will comprise three beamlines. The first line to be built has been devised to apply the multiwavelength anomalous diffraction method which provides direct estimates for the phases of reflections. The second line will be devoted to rapid and essentially routine diffraction measurements, mainly through the rotation method. These two experimental stations are contained within refrigerated radiation enclosures that will maintain clean environments, narrowly defined constant temperatures, and protection against biohazard at biosafety level BL-2. At the same time as the second line will be developed, the swath center is planned to first serve as a monitor of the white ...
1989-07-01
Physics of electron beam therapy
International Nuclear Information System (INIS)
A book has been written to introduce the physical aspects of the radiotherapy electron beam by presenting a summary of the developments in this field. The first chapter is a brief introduction to the technology of medical accelerators with emphasis on the electron beam production facilities. Chapter 2 describes the interaction processes at the atomic level once the electron beam enters the medium. Chapter 3 is concerned with the various properties of the electron beam purely from the clinical point of view. The electron beam algorithms and models for distribution calculations are covered in Chapter 4 with inclusion of age diffusion and multiple scattering approaches. The factors affecting the beam distribution in a patient, with inhomogeneities, surface irregularities, backscattering etc. are discussed in Chapter 5. The last two chapters are devoted to electron beam dosimetry including various dosimetric methods, specification and measurement of beam energy, ...
Overview of Chuetsu-oki earthquake and evaluation of seismic safety
International Nuclear Information System (INIS)
The Chuetsu-oki Earthquake strongly shook the Kashiwazaki-Kariwa Nuclear Power Station with the ground motions exceeding the design values. The incidents include a fire breakout of the Unit 3 transformer, a release of spilled water containing small amount of radioactive materials to the non-radiation control area and subsequently to the environment at Unit 6, and a release of radioactive material from the main turbine condenser through the main stack of Unit 7 due to the delay stooping the turbine gland steam ventilator by the operator in manually, while every unit in operation was safety shutdown in the automatic mode ensuring the three fundamental safety functions of (a) reactivity control, (b) removal of heat from the core and (c) confinement of radioactive materials. Following integrity evaluation and performance testing of the overall plant, seismic safety of buildings, structures, equipment and pipelines on the basis of the basic ...
2010-07-01
International Nuclear Information System (INIS)
The authors present arguments against nuclear energy and pro renewable energy sources. Thus, the water used in Uranium mining and primary ore processing becomes contaminated in long lived radioisotopes and so a threat for local ecosystems and communities. Then, during the fabrication, enrichment, and handling of nuclear fuel the workers are exposed to radiations and dangerous accidental radioactive leaks can occur. But, by far, the most menacing aspect of nuclear power exploitation remains the human errors in operating the nuclear plants which can result in major accidents like that from Chernobyl which spread radioactivity all over the Europe. The equipment used in nuclear facilities which is highly contaminated as well as the burned fuel implies transportation and long term storage which also present high risks. The major advantage of the nuclear energy consists in its very low environment impact and its null contribution to the greenhouse ...
1996-03-15
Mechanical Engineering and Design of the LHC Phase II Collimators
Phase II collimators will complement the existing system to improve the expected high RF impedance and limited efficiency of Phase I jaws. An international collaborative effort has been launched to identify novel advanced materials responding to the very challenging requirements of the new collimators. Complex numerical calculations simulating extreme conditions and experimental tests are in progress. In parallel, an innovative modular design concept of the jaw assembly is being developed to allow fitting in alternative materials, minimizing the thermally induced deformations, withstanding accidents and accepting high radiation doses. Phase II jaw assembly is made up of a molybdenum back-stiffener ensuring high geometrical stability and a modular jaw split in threes sectors. Each sector is equipped with a high-efficiency independent cooling circuit. Beam position monitors (BPM) are embedded in the jaws to fasten setup time and improve beam ...
2010-01-01
FFTF [Fast Flux Test Facility] cesium trap design, installation, and operating experience
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a 400-MWt, sodium-cooled reactor located on the Hanford Site near Richland, Washington, USA. The FFTF is owned by the U.S. Department of Energy and is operated by the Westinghouse Hanford Company. The FFTF was designed to test fuels and materials for use in liquid metal reactors. Since initial operation in 1982, anticipated breaches of experimental fuel pins have released fission products, including cesium, into the primary sodium. Because of its high volatility, cesium vaporizes into the cover gas space, where it condenses on components and equipment and is transported into the cover gas outlet. Because of the long half-life of "1"3"7Cs, these deposits result in long-term, local radiation levels that make contact maintenance difficult. Thus, a cesium trap was installed in FFTF to reduce the cesium level in the sodium. The trap could also permit a Run Beyond Cladding Breach (RBCB) program without ...
1988-10-17
Design modifications in 540 MWe and its impact on the dose rates
International Nuclear Information System (INIS)
Exposure control at the operating Nuclear Power Station is a major concern. TAPS Unit-4 is the first Pressurized Heavy Water Reactor of 540 MWe electrical capacity. This unit was made critical on March 6, 2005. In-depth review of radiation safety was done to identify the impact of design modification on dose rates at various locations and on the equipment's. Problems encountered in controlling the dose rates in 220 MWe electrical are eliminated by appropriate design modifications. Due to higher capacity of the unit there are design changes in major systems such as reactor core, primer heat transport system, moderator system, reactor regulation and protection systems. Reactor operations and maintenance activities during shut down contributes to exposure of the employees. Based on the experience gained in the operation of 220 MWe, design modifications incorporated in TAPS unit-4 and dose rate measurements carried out at 90 % full power, through ...
2005-11-23
A new measurement of the antiproton-to-proton flux ratio up to 100 GeV in the cosmic radiation
A new measurement of the cosmic ray antiproton-to-proton flux ratio between 1 and 100 GeV is presented. The results were obtained with the PAMELA experiment, which was launched into low-earth orbit on-board the Resurs-DK1 satellite on June 15th 2006. PAMELA is equipped with a silicon-microstrip magnetic spectrometer and a silicon-tungsten imaging calorimeter and has been collecting data since July 2006. During 500 days of data collection a total of about 1000 antiprotons have been identified, including 100 above an energy of 20 GeV. The high-energy results are a ten-fold improvement in statistics with respect to all previously published data. The antiproton-to-proton flux ratio increases smoothly with energy up to about 10 GeV, in agreement with previous experiments, and then levels off. The data follow the trend expected from secondary production calculations and significantly constrain contributions from exotic sources, e.g. dark matter particle annihilations.
2008-01-01
Study on dose distribution of therapeutic proton beams with prompt gamma measurement
Energy Technology Data Exchange (ETDEWEB)
The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma distribution was compared to the dose distribution measured by an ionization chamber at three different ...
2007-03-15
Whole-body counting in the Marshall Islands
Energy Technology Data Exchange (ETDEWEB)
In 1978 the Marshall Islands Radiological Safety Program was organized to perform radiation measurements and assess radiation doses for the people of the Bikini, Enewetak, Rongelap and Utirik Atolls. One of the major field components of this program is whole- body counting (WBC). WBC is used to monitor the quantity of gamma- emitting radionuclides present in individuals. A primary objective of the program was to establish {sup 137}Cesium body contents among the Enewetak, Rongelap and Utirik populations. {sup 137}Cs was the only gamma-emitting fission radionuclide detected in the 1,967 persons monitored. {sup 137}Cs body burdens tended to increase with age for both sexes, and were higher in males. The average {sup 137}Cs dose Annual Effective Dose for the three populations was as follows: For Enewetak, the dose was 22{+-}4 {mu}Sv. For Utirik, the dose was 33{+-} 3 {mu}Sv. Since 1985 the Rongelap people have been self-exiled ...
1991-01-01
International Nuclear Information System (INIS)
We report on the first measurements of the z-dependent evolution of electron-beam microbunching as revealed through coherent transition radiation (CTR) measurements in a visible self-amplified spontaneous emission free-electron laser experiment. The increase in microbunching was detected by tracking the growth of the visible CTR signals as generated from insertable metal mirrors/foils after each of the last three undulators. The same optical imaging diagnostics that were used to track the z-dependent intensity of the undulator radiation (UR) were also used to track the electron beam/CTR information. Angular distribution, beam size, and intensity data were obtained after each of the last three undulators in the five-undulator series, and spectral information was obtained after the last undulator. The exponential growth rate of the CTR was found to be very similar to that of the UR and consistent with simulations using the ...
2002-07-01
International Nuclear Information System (INIS)
We report on the first measurements of the z-dependent evolution of electron-beam microbunching as revealed through coherent transition radiation (CTR) measurements in a visible self-amplified spontaneous emission free-electron laser experiment. The increase in microbunching was detected by tracking the growth of the visible CTR signals as generated from insertable metal mirrors/foils after each of the last three undulators. The same optical imaging diagnostics that were used to track the z-dependent intensity of the undulator radiation (UR) were also used to track the electron beam/CTR information. Angular distribution, beam size, and intensity data were obtained after each of the last three undulators in the five-undulator series, and spectral information was obtained after the last undulator. The exponential growth rate of the CTR was found to be very similar to that of the UR and consistent with simulations using the ...
2001-12-21
Synchrotron Self-Compton Analysis of TeV X-ray Selected BL Lacertae Objects
We introduce a methodology for analysis of multiwavelength data from X-ray selected BL Lac (XBL) objects detected in the TeV regime. By assuming that the radio--through--X-ray flux from XBLs is nonthermal synchrotron radiation emitted by isotropically-distributed electrons in the randomly oriented magnetic field of a relativistic blazar jet, we obtain the electron spectrum. This spectrum is then used to deduce the synchrotron self-Compton (SSC) spectrum as a function of the Doppler factor, magnetic field, and variability timescale. The variability timescale is used to infer the comoving blob radius from light travel-time arguments, leaving only two parameters. With this approach, we accurately simulate the synchrotron and SSC spectrum of flaring XBLs in the Thomson through Klein-Nishina regimes. Photoabsorption by interactions with internal jet radiation and the intergalactic background light (IBL) is included. Doppler ...
2008-01-01
International Nuclear Information System (INIS)
Non-destructive methods of diagnosis for detecting cable degradation by aging are being studied recently for improvement of electric wires and cables. This study examines degradation behaviors of cable sheath and insulation by combined accelerated aging tests applying thermal and radiation stresses simultaneously using a typical low voltage cable. According to experiments, elongation of cross-linked polyethylene insulation deteriorated at a faster rate than PVC sheath did under low doses below 50 Gy/h. Therefore, measurements using a time domain dielectric spectrometer (TDS) were carried out for the purpose of developing a method of degradation diagnosis of insulation. It was found that values of tan#delta# measured at very low frequencies below 0.1 Hz increase in pace with degradation of insulation reflecting the level of degradation more effectively than those measured at frequencies around the commercial frequency. In order to consider ...
2000-05-01
Gap-junctional communication of bone marrow stromal cells is resistant to irradiation in vitro
Energy Technology Data Exchange (ETDEWEB)
Bone marrow is one of the most radiosensitive organs. Irradiation causes a marked decrease in the total number of hematopoietic cells in the bone marrow. The reticular meshwork structure of marrow stromal cells, however, is relatively resistant to irradiation. Unimpaired stromal cell structure has been thought to be a prerequisite for the repopulation of hematopoietic cells during recovery from the effects of irradiation. The reticular framework is maintained by cell adhesion apparatuses such as gap junctions. The in vitro radiobiologic survival values of a cloned stromal cell line, H-1/A, were studied (n = 1.8, D0 = 138 cGy). Radiation doses of up to 4000 cGy had no detectable effects on the production of colony-stimulating factor 1. H-1/A cells communicate with each other via gap junctions as determined by the sensitive dye-transfer method. Gap-junctional communication between H-1/A cells was resistant to different levels of irradiation (500 ...
1990-10-01
Gap-junctional communication of bone marrow stromal cells is resistant to irradiation in vitro
International Nuclear Information System (INIS)
Bone marrow is one of the most radiosensitive organs. Irradiation causes a marked decrease in the total number of hematopoietic cells in the bone marrow. The reticular meshwork structure of marrow stromal cells, however, is relatively resistant to irradiation. Unimpaired stromal cell structure has been thought to be a prerequisite for the repopulation of hematopoietic cells during recovery from the effects of irradiation. The reticular framework is maintained by cell adhesion apparatuses such as gap junctions. The in vitro radiobiologic survival values of a cloned stromal cell line, H-1/A, were studied (n = 1.8, D0 = 138 cGy). Radiation doses of up to 4000 cGy had no detectable effects on the production of colony-stimulating factor 1. H-1/A cells communicate with each other via gap junctions as determined by the sensitive dye-transfer method. Gap-junctional communication between H-1/A cells was resistant to different levels of irradiation (500 ...
ESR dosimetry of irradiated chicken legs and chicken eggs
Energy Technology Data Exchange (ETDEWEB)
Ionising radiation induces stable free radicals in chicken bones and in the shell of chicken eggs which can be detected, by the electrons spin resonance (ESR) technique, well beyond the shelf-life of the food and can be used for dosimetry. The method usually adopted to evaluate ``a posteriori`` the dose given during the ionising radiation treatment of food, is the dose additive method. To assess the dose, the ESR signal amplitude of the irradiated food (bone or egg shell in the present case) is measured and then the dose-effect relationship is obtained by re-irradiating the sample with some additive doses (usually of 1 kGy). The dose-effect curve is back-extrapolated and the initial given dose determined. At the Istituto Superiore di Sanita (ISS), Rome, Italy, a research programme was approved two years ago aimed to, (1) study new methodological approaches for ESR dose assessment, and (2) analyse the factors which may ...
1996-12-31
DOE personnel neutron dosimetry evaluation and upgrade program
Energy Technology Data Exchange (ETDEWEB)
The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. An Effective Dose ...
1988-10-01
Air conditioner for radioactive material handling facility
Energy Technology Data Exchange (ETDEWEB)
An air conditioner intakes open-air from an open-air intake port to remove sands and sea salt particles by air filters. Then, natural and artificial radioactive particles of less than 1 {mu}m are removed by high performance particulate filters. After controlling the temperature by an air heater or an air cooler, air is sent to each of chambers in a facility under pressure elevation by a blower. In this case, glass fibers are used as the filter material for the high performance particulate filter, which has a performance of more than 99.97% for the particles of 0.3 {mu}m grain size. Since this can sufficiently remove the natural radioactive materials intruded from the outside, a detection limit value in each of the chambers of the facility can be set 10{sup -13} to 10{sup -14} {mu}ci/cm{sup 3} in respect of radiation control. Accordingly, radiation control can be conducted smoothly and appropriately. (I.N.).
1991-04-26
Theoretical considerations for X-ray phase contrast mammography by Thomson source
Energy Technology Data Exchange (ETDEWEB)
The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase imaging with respect to standard absorption imaging, in the specific case of ...
2009-09-01
TeV gamma-rays from the Northern sky pulsar wind nebulae
Energy Technology Data Exchange (ETDEWEB)
We estimate the TeV {gamma}-ray fluxes expected from the population of young pulsars in terms of the self-consistent time-dependent hadronic-leptonic model for the high-energy processes inside the pulsar wind nebulae (PWNe). This radiation model is based on the hypothesis of Arons and collaborators who postulate that leptons are accelerated inside the nebulae as a result of resonant scattering on heavy nuclei, which in turn are accelerated in the pulsar wind region or the pulsar inner magnetosphere. Our aim is to find out which PWNe on the northern hemisphere are the best candidates for detection at energies above 60 GeV and 200 GeV by the next generation of low-threshold Cherenkov telescopes.
2005-12-01
Energy Technology Data Exchange (ETDEWEB)
Metallic nanoparticles was synthesized in SiO{sub 2} matrices by means of a process of two stages. The first one proceeded via sol-gel, incorporating the metallic precursors to the reaction system before the solidification of the matrix. Later on, the samples underwent a thermal treatment in atmosphere of H{sub 2}, carrying out the reduction of the metals that finally formed to the nanoparticles. Then it was detected the presence of smaller nanoparticles than 20 nm, dispersed and with the property of being liberated easily of the matrix, conserving a free surface, chemically reactive and with response to external electromagnetic radiation. The system SiO{sub 2}-Pd showed an important thermoluminescent response. (Author)
2004-07-01
Spectroscopy of gadolinium gallium garnet crystals doped with Y b3+ revisited
International Nuclear Information System (INIS)
The optical spectroscopy measurements of gadolinium gallium garnet (GGG) crystals doped with Yb show evidence of the presence of non-equivalent optical centers with very similar radiative decay rates. The energy level schemes of those centers have been determined on the basis of optical absorption, luminescence and Raman experiments. Crystal field fitting resulted in two sets of slightly different crystal field parameters for two non-equivalent Yb centers. Both sets of parameters describe perfectly the experimentally detected Y b3+ energy levels. Correlation between systematic trends in the experimental energy level schemes and crystal field parameters is discussed.
2010-06-30
Reduction of fluoroscopic exposure for the air-contrast barium enema
Energy Technology Data Exchange (ETDEWEB)
In a fluoroscopic imaging system, image quality and patient dose are both affected by the optical system linking the image intensifier with the video camera. The effect on patient exposure of increasing the optical iris aperture size over that required for other procedures performed on the same imaging system was investigated for the air-contrast barium enema examination. Using a large-area transmission ionisation chamber to monitor the Roentgen-area-product of entrance exposure, a decrease in fluoroscopic radiation of greater than 50% was clinically documented for a fluoroscopic system utilising kVp and mA variable automatic brightness control. For this iris change, the video image was of acceptable quality for positioning and monitoring the patient, and no deleterious effect was detected in the conduct of the air-contrast exam. The availability of a variable-sized operator-selectable iris diaphragm would permit this dose-reduction approach to ...
1983-11-01
International Nuclear Information System (INIS)
Radiological and environmental protection experience associated with the reactor cover gas processing system at the Fast Flux Test Facility (FFTF) has been excellent. Personnel radiation exposures received from operating and maintaining the reactor cover gas processing system have been very low, the system has remained free of radioactive particulate contamination through the first seven operating cycles (cesium contamination was detected at the end of Cycle 8A), and releases of radioactivity to the environment have been very low, well below environmental standards. This report discusses these three aspects of fast reactor cover gas purification over the first eight operating cycles of the FFTF (a duration of a little more than four years, from April 1982 through July 1986).
1986-09-24
Quantitative measurement of elements in a composite, using multienergy gamma-rays
International Nuclear Information System (INIS)
This study is an attempt to measure the quantities of elements in a composite by irradiating that composite with #gamma#-rays of various energies and detecting the transmitted radiation through the composite. A previous knowledge of the number of the elements and their attenuation coefficients is required. The quantities are calculated by solving the matrix of a linear system of equations. A computer program was developed to select the best combinations of the available energies. Five criteria were established to determine these energy combinations: (i) the determinant of the attenuation coefficient matrix; (ii) the condition number, (iii) the number of times the solution of the matrix leads to acceptable results; (iv) the indicator, (a new concept); (v) the standard deviations of the results. The intended application of this technique in medicine is to measure the bone mineral content of the skeleton. An examination of the error propagation, ...
Energy Technology Data Exchange (ETDEWEB)
Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A /sup 238/Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed.
1981-01-01
International Nuclear Information System (INIS)
Increased levels of epidermal growth factor receptor have been reported in a variety of tumors, including pulmonary squamous cell carcinomas in man. The purpose of this study was to determine if increased levels of epidermal growth factor (EGFR) were present in lung tumors from Beagle dogs that had been exposed to "2"3"9PuO_2- Using immunohistochemical techniques, sections from 17 lung tumors were examined for the presence of EGFR. Seven of the tumors were strongly positive for EGFR; the remainder of the tumors and the normal lung sections were negative. The positive immunostaining could not be correlated with the histologic phenotype of the tumors. Work is in progress to determine the level of EGFR in preneoplastic, proliferative epithelial foci in the Iung. (author)
1988-12-01
Experiments on determination of damage effect ions "2"2Ne (172 MeV) on UO_2 monocrystals
International Nuclear Information System (INIS)
Shadow effect was used for investigating damage of uranium dioxide monocrystal. The dependence of shadow minimum parameters on fluence of "2"2Ne ions with 172 MeV energy was followed when detecting fission fragments. Ion dose responsible for sufficient microdamage of lattice structure, included into the classification of heavy ion damage effect on monocrystals was determined. The problem of radiation intensity effect on the character of occurred damages was studied. It was established that macroscopic sample failure, caused by generation of considerable mechanical stresses in monocrystal under beam effect could be observed along with microdamages of lattice structure at ion flux density >10"1"2 cm"-"2Xs"-"1.
British Library Electronic Table of Contents (United Kingdom)
Even if there have been efforts to validate remote-sensing-based energy balance models, which provide evapotranspiration (ET) maps over a large spatial scale, few studies have been conducted to validate their performance in Korea. In this study, surface energy balance fluxes including ET were estimated and inter-compared with two different models using the Landsat-5 Thematic Mapper (TM) image over a watershed scale in Korea. While there were larger spatial discrepancies for net radiation, soil heat and sensible heat fluxes on a pixel-by-pixel basis between the two models, relatively smaller spatial discrepancies for the latent heat flux and daily ET were detected. The spatial discrepancies for the daily ET were larger in low topography and dense vegetation ranges. Despite the different par...
2011-01-01
Characterization of the combustion of biomass producer gas in a constant volume combustion bomb
British Library Electronic Table of Contents (United Kingdom)
In this article a methodology is presented for studying the influence of the biomass moisture content and the biomass/air ratio on the producer gas composition and on the chemiluminescent emissions during the combustion process. Firstly, a mathematical model based on the thermo-chemical processes inside the gasifier is used to predict the composition of the producer gas as a mixture of CO, CO2, H2, N2, CH4 and H2O gases. Secondly, the predicted composition is introduced into a constant volume combustion bomb (CVCB), which simulates the typical conditions inside the combustion chamber of an internal combustion engine, in order to characterize its combustion under gasoline-type conditions through the instantaneous pressure and the detection of the spontaneous luminous radiation (chemilumines...
2010-01-01
Ultrasensitive fluorescence detection of DNA
Progress on Ultrasensitive fluorescence detection of DNA is briefly described. (CBS)
1991-01-01
Fluorescent Silicate Materials for the Detection of Paraoxon
... significantly lower limits of detection. The complex fluorescence spectra of these constructs indicated that only a portion ...
2010-03-19
International Nuclear Information System (INIS)
Monitoring nuclear plants components enable to save on operation and maintenance costs by reducing incidents gravity and casual plant stoppages thank to early detection and fast diagnosis. Improving the knowledge of the behaviour of the plant will also allow to optimize maintenance and to increase plant life. In order to improve monitoring and diagnosis capabilities in nuclear power plants. Electricite de France (EDF) is extending the existing data processing chains towards automatic aided interpretation and diagnosis. Therefore, EDF has designed an integrated monitoring and diagnosis assistance system: PSAD-Poste de Surveillance et d'Aide au Diagnostic, including several monitoring functions of the main components. It integrates on-line monitoring, off-line diagnosis and knowledge based systems. PSAD stations provide homogeneous aids to diagnosis which enable plant personnel to pinpoint the mechanical behaviour of plant equipment. The ...
1997-04-14
The Use of Medical Images in Planning and Delivery of Radiation Therapy
UK PubMed Central (United Kingdom)
Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available
1997-09-01
Animal Models for Radiation Injury, Protection and Therapy
... radiation during clinical therapy and exposures due to radiation accidents or attacks, in which the doses are uncontrolled ... only be used off-label in victims of radiation accidents or attacks. The idea...
Inventory of Tank Farm equipment stored or abandoned aboveground
Energy Technology Data Exchange (ETDEWEB)
This document provides an inventory of Tank Farm equipment stored or abandoned aboveground and potentially subject to regulation. This inventory was conducted in part to ensure that Westinghouse Hanford Company (WHC) does not violate dangerous waste laws concerning storage of potentially contaminated equipment/debris that has been in contact with dangerous waste. The report identifies areas inventoried and provides photographs of equipment.
1994-10-12
Contamination preventive method and decontaminating method for equipment
Energy Technology Data Exchange (ETDEWEB)
The method of the present invention comprises a step of previously coating a positive type resist on the surface of equipment, a step of solidifying the coated positive type resist and a step of bringing the coated equipment to circumstances for use and cleaning the positive type resist. With such procedures, the amount of radioactive materials deposited on the equipment can be reduced, and redeposition of nuclides on the surface to be cleaned can be prevented. (T.M.)
1998-12-04
DoseWatchers - A computer based X ray dose monitoring project in paediatric radiology
International Nuclear Information System (INIS)
Full text: Introduction. Children, especially premature infants and neonates, are at a much higher risk to obtain an X ray induced disturbance of life - particularly cancer. On the one hand this is due to their longer life expectancy and on the other hand it is due to their higher cell proliferation rate. The paediatric radiology unit of the Inselspital Bern recently installed some of the most advanced X ray equipment nowadays available. It is based on the two latest digital technologies: double read computed radiography (CR) and direct digital radiography (DR). Only the implementation of these digital radiography systems permits the digital acquisition and additionally the analysis of acquired data. The systematic analysis of large amounts of biometric data and exposition data is the basis for further dose reduction and a systematic quality control (QC). Patients are increasingly critical concerning radiation exposure - especially parents ...
2006-11-13
Replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory
Energy Technology Data Exchange (ETDEWEB)
The DOE-Idaho Operations Office (DOE-ID) has prepared an environmental assessment (EA) on the replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory at the Idaho National Engineering Laboratory (INEL). The purpose of this project is to replace the existing Health Physics Instrumentation Laboratory (HPIL) with a new facility to provide a safe environment for maintaining and calibrating radiation detection instruments used at the Idaho National Engineering Laboratory. The existing HPIL facility provides portable health physics monitoring instrumentation and direct reading dosimetry procurement, maintenance and calibration of radiation detection instruments, and research and development support-services to the INEL and others. However, the existing facility was not originally designed for laboratory activities and does not provide an adequate, safe environment ...
1995-05-01
Energy Technology Data Exchange (ETDEWEB)
A method for detecting electrons emitted as secondary particles by photon incidence to a specimen, as well as a method of using the photons emitted by electron incidence as detecting particles are explained. Pd-Si(100)2{times}1 system is adopted for a case study of using photo-electron spectroscopy where synchrotron emitted light in soft X-ray region is used as the incident light. Pd atoms are deposited little by little on clean Si surface to investigate the electron structure of the surface, and the interface electron structure after bonded formation of Pd(thin film)-Si(substrate) is estimated. Radiation soft X-ray spectroscopy is employed to observe the real state of the bonded interface of Pd(thin film)-Si(substrate) prepared by depositing Pd film in a short period of time. In the case of radiation soft X-ray spectroscopy with electron beam excitation, bonded system of thin film and substrate can be ...
1995-07-20
In situ texture analysis under applied load
International Nuclear Information System (INIS)
The in-situ measurement of a crystallographic texture is a special type of a non-destructive measurement, which need special equipments. Due to the high photon flux and the excellent brilliance high energetic synchrotron radiations are a fantastic tool particular in fast experimentation. Moreover, a high penetration power allows the investigation of standard tensile sample of the DIN-norm. A loading device with a power up to 20 kN was installed at the hard wiggler beamline BW5 (HASYLAB-DESY) to perform in-situ strain and in-situ texture analysis. Using 100keV X-rays one gets short wavelength so that a 2D image-plate detector offers a wide range of diffraction pattern within the first 10 degree in 2 theta. Thermal neutron is another radiation with a high penetration power, which is the standard method for global texture analysis of bulk samples. As an example rectangular extruded Mg- Az31 was investigated by an in-situ. ...
Environmental data for sites in the National Solar Data Network
Energy Technology Data Exchange (ETDEWEB)
The Detartment of Energy's National Solar Data Program established solar energy systems in residential and commercial buildings across the United States. These solar sites are linked to Vitro Laboratories Division's computer in the National Solar Data Network (NSDN). Vitro collects and analyzes data from this network to determine the thermal performance of each of the solar systems. Environmental information collected at the sites for the month of August 1980 is presented. The environmental data for the NSDN are presented in the form of tables for each solar site. The solar sites are grouped into 12 zones, each of which consists of several adjacent states. The solar energy sites are in alphabetical sequence within each zone. The tables provide available meteorological data for reporting sites in the NSDN as follows: (1) Insolation: the insolation table presents the total, diffuse, direct, maximum, and extra-terrestrial radiation for the solar ...
1980-08-01
Cryogenic coolers are often used in modern spacecraft in conjunction with sensitive electronics and sensors of military, commercial and scientific instrumentation. The typical space requirements are: power efficiency, low vibration export, proven reliability, ability to survive launch vibration/shock and long-term exposure to space radiation. A long-standing paradigm of exclusively using "space heritage" equipment has become the standard practice for delivering high reliability components. Unfortunately, this conservative "space heritage" practice can result in using outdated, oversized, overweight and overpriced cryogenic coolers and is becoming increasingly unacceptable for space agencies now operating within tough monetary and time constraints. The recent trend in developing mini and micro satellites for relatively inexpensive missions has prompted attempts to adapt leading-edge tactical cryogenic coolers for suitability in the space ...
2011-05-01
Monitoring of DNA and cytogenetic damage in lymphocytes from persons with skin cancer diseases
International Nuclear Information System (INIS)
There is a lot of interest in the studies that would help to understand whether there is a casual association between cancer and various types of molecular or cytogenetic damage detected in human cells. One major oncogenesis process is activation of proto-oncogenes by point mutations or chromosomal translocation. There are substantial evidence that indicates that the loss of heterozygosity of certain chromosomes is involved in human cancerogenesis. Our study aimed to elicit the possible association between cancer and DNA and cytogenetic abnormalities induced in lymphocytes of people bearing various categories of skin cancer cells. Fresh blood was collected by venipuncture from 25 individuals (including nine prior to cancer treatment). All patients were nonsmoking males, however 42.3 % of them were former smokers. Blood samples were divided into two parts and in the first part of samples cytogenetic studies were performed immediately, while from the second part ...
2004-11-01
Energy Technology Data Exchange (ETDEWEB)
The US DOE manages the safe storage of approximately 650,000 tons of depleted uranium hexafluoride remaining from the Cold War. This slightly radioactive, but chemically active, material is contained in more than 46,000 steel storage cylinders that are located at Oak Ridge, Tennessee; Paducah, Kentucky; and Portsmouth, Ohio. Some of the cylinders are more than 40 years old, and approximately 17,500 are considered problem cylinders because their physical integrity is questionable. These cylinders require an annual visual inspection. The remainder of the 46,000-plus cylinders must be visually inspected every four years. Currently, the cylinder inspection program is extremely labor intensive. Because these inspections are accomplished visually, they may not be effective in the early detection of leaking cylinders. The inspection program requires approximately 12--14 full-time-equivalent (FTE) employees. At the cost of approximately $125K per FTE, this translates to ...
1997-02-01
Energy Technology Data Exchange (ETDEWEB)
The overall goal of the proposed project is to explore the use of partitioning tracers to characterize dense nonaqueous phase liquids (DNAPLs) in aquifer systems. Bulk-phase partitioning tracers will be investigated to detect and determine DNAPL saturation, while interface partitioning tracers will be investigated to measure the area of the DNAPL-water interface. The specific objectives that will be addressed to accomplish this goal are: (1) Investigate the use of partitioning tracers to detect and determine both the saturation and interfacial area of DNAPLs in saturated porous media. (2) Investigate the effect of rate-limited mass transfer on the transport behavior of partitioning tracers. (3) Investigate the effect of porous-media heterogeneity on the transport behavior of partitioning tracers. (4) Develop and evaluate mathematical models capable of simulating the transport of partitioning tracers in complex systems. This proposal outlines an ...
2000-09-14
International Nuclear Information System (INIS)
We describe a new apparatus that combines pulsed laser excitation in a molecular beam with surface-science methods for preparation of clean single-crystal surfaces and detection of adsorbates to enable state-selected studies of gas-surface reaction dynamics. Reactant molecules are prepared in specific vibrationally excited states via overtone pumping using tunable, narrow-band laser radiation. The collision-free environment of the molecular beam prevents relaxation of the prepared molecules before impact on the target surface and enables complete control over the collision energy and incidence angle. Chemisorption products are detected after a given deposition time by Auger electron spectroscopy. To achieve sufficient beam flux of state-selected reactant molecules for product detection by standard surface-science techniques, we use a high-intensity, short-pulse molecular-beam source matched to the low ...
2003-09-01
International Nuclear Information System (INIS)
Computed tomography would be a better method to detect and characterize a Thorotrast-induced liver tumour. The selective opacification of the RES by Thorotrast creates an intrinsic opacification of the liver similar in effect to contrast agents being evaluated for liver CT, such as ethoioidized oil emulsion. The computed tomographic appearance of Thorotrast-associated cholangiocarcinoma is usually a large, inhomogenous mass composed of disordered area of tissue of high density due to Thorotrast deposits, and of very low density. Thorotrast-induced cholangiocarcinoma originates in the peripheral biliary tree suprounding the highest mean concentration of Thorotrast deposition, so that visible soft tissue masses in the higher density spots in the liver are not produced in the early stage. The tendency for the opacity of the liver to decrease slowly with time and result in an uneven trabeculation and high density spots suggests that small tumors may be difficult to ...
Environmental monitoring data were collected at and around the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) at the Nevada Test Site. These data are associated with radiation exposure, air, groundwater, meteorology, vadose zone, subsidence, and biota. This report summarizes the 2006 environmental data to provide an overall evaluation of RWMS performance and to support environmental compliance and performance assessment (PA) activities. Some of these data (e.g., radiation exposure, air, and groundwater) are presented in other reports (U.S. Department of Energy, 2006; Warren and Grossman, 2007; National Security Technologies, LLC, 2007). Direct radiation monitoring data indicate that exposure levels around the RWMSs are at or below background levels. Air monitoring data at the Area 3 and Area 5 RWMSs indicate that tritium concentrations are slightly above background levels. There is no ...
2007-06-30
International Nuclear Information System (INIS)
... radiation effects human populations low dose irradiation neoplasms radiation
1980-01-01
Radiation protection and the management of radioactive waste in the oil and gas industry
Radiation protection and the management of radioactive waste in the oil and gas industry
2003-01-01
Influence of germanium and oxygen impurities on the radiation hardening of monocrystalline silicon
International Nuclear Information System (INIS)
... defects doped materials germanium infrared radiation monocrystals neutron
Higher harmonics of spontaneous radiation of ultrarelativistic channeled particles
International Nuclear Information System (INIS)
The case of spontaneous radiation of channeled ultrarelativistic particles is considered when the dipolarity condition is not satisfied. The change of the particle longitudinal velocity affecting the maximum radiation frequency is included. The angular and frequency characteristics of the radiation for superhigh energies are studied for the first time. It is shown that there is an optimum energy at which the radiation density is maximum. The influence of the angle at which electrons enter a crystal and of the beam divergence on the radiation is investigated. The problem of quasichanneled particle radiation and also the radiation in axis-plane transitions are considered. (author).
1980-06-01
International Nuclear Information System (INIS)
... pathological changes patients radiation protection radiotherapy diseases
1982-10-25
Contribution to the radiation preparation of wood-plastic materials. Pt. 7
International Nuclear Information System (INIS)
... odd nuclei organic compounds radiation effects radioisotopes synthesis
1974-01-01
Contribution to the radiation preparation of wood-plastic materials. Pt. 6
International Nuclear Information System (INIS)
... compounds polymers polyolefins polyvinyls radiation effects SYNTHESIS.
1974-01-01
Contribution to the radiation preparation of wood-plastic materials Pt. 3
International Nuclear Information System (INIS)
... compounds plants radiation effects radioisotopes reaction kinetics trees
1974-01-01
duced and spontaneous radiation. The amount of polarization is ... of the induced and spontaneous radiation patterns. Therefore ...
International Nuclear Information System (INIS)
The fundamental optical absorption of ion crystals characterizes the creation of different free low energetic electronic excitation (the excitons and electron-hole pairs), but their straight registration is not possible because of incommensurable big absorption factor of alkali halide monocrystals. So to registration the spectrums of alkali halide monocrystal very fine layers are necessary. We have received fine films of Nal and KCl in system of KCl-Nal-KCl, KCl-KI-KCl on the base of universal vacuum post VUP-4, VUP-5 by thermal evaporation. A unique spectral unit has been created For this on the basic the SDL-2 complex. Complex consists of radiator, systems of condensers, monochromators MDR-12 and MDR-23, receivers of radiation, controller by unit. Connect and control of monochromators by means of IBM-compatible computer has been created. Kinematics schemes of monochromators provide consequent removing on output slot of monochromatic ...
Clinical implementation of a convolution based algorithm for 3D treatment planning
International Nuclear Information System (INIS)
Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A computer controlled data acquisition system and a ...
Standardizing regulations on production of mining electrical equipment
Energy Technology Data Exchange (ETDEWEB)
The paper evaluates standardization of regulations on safety of electrical equipment for underground coal mines in the USSR. Factors increasing hazards of electrical failures of equipment in underground coal mines are analyzed: reduced lighting, increased humidity and dusts, damage caused by falling rocks or damage during haulage in underground workings, installation of electrical equipment in places easily accessible to untrained personnel. Standards on safety of electrical equipment for underground coal mining valid in the USSR are reviewed: the PIRNEh regulations on production of electrical equipment for coal mines developed by the VNIIVEh Institute, and the GOST national standards. International cooperation within the COMECON on safety of mining electrical equipment (the Interelectro Committee of the COMECON) is described. Certification of electrical ...
1983-02-01
International Nuclear Information System (INIS)
Full text: Founded in 1964, Ankara Nuclear Research and Training Center (ANRTC) conducts and facilitates the scientific activities including training (summer practice, MSc and Ph D studies in physics and chemistry, IAEA fellowship programs etc.), research and other studies in nuclear and related fields. As it's a part of main duties, ANRTC has analysis on the variety of samples, and radiation protection services commercially, for radiation workers in state, public and private sectors. Research, development and application projects implemented in this Center have mostly been supported by State Planning Organization (SPO) and Turkish Atomic Energy Authority (TAEA). In addition to the projects there are on going collaborative studies with some national Universities and International Atomic Energy Agency. The main activities carried out in ANRTC can be summarized as: studies on experimental nuclear physics, application of nuclear techniques such as ...
2004-10-01
The Differentially Expressed Genes by Radiotherapy in the Patients with Uterine Cervix Cancer
Energy Technology Data Exchange (ETDEWEB)
Purpose : To detect differentially expressed genes in the patients with uterine cervical cancer during the radiation therapy. Materials and Methods : In patients with biopsy proven uterine cervical cancer, we took a tumor tissue just before radiation therapy and at 40 minutes after external irradiation of 1.8 Gy. Total RNAs isolated from non-irradiated and irradiated tumor tissue samples were analyzed using the differential-display reverse transcription-polymerase chain reaction (DDRT-PCR). Complementary DNA (cDNA) fragments corresponding to differentially expressed messenger RNAs(mRNAs) were eluted, and cloned. The differential expression of the corresponding mRNAs was confirmed by reverse northern blot. Differentially expressed cDNA bands were sequenced. Nucleotide sequence data were analyzed in the Gene Bank and EMBL databases via the BLAST network server to identify homologies to known genes or cDNA fragments. ...
2001-12-15
Predictive model of electron-beam-induced flashblindness. Final report, November 1983-October 1984
Energy Technology Data Exchange (ETDEWEB)
The spectral characteristics of the Cherenkov radiation have been evaluated and converted to equivalent retinal irradiance from external sources. On the basis of the conversion, electron fluxes have been estimated for 2-sec recovery times from flashblindness. The electrons are assumed to have energies greater than 6 MeV and to be delivered in one or more bursts of 1 microsecond each over 1 sec. It is important to note that very little data exists on recovery times as short as 2 sec for either photopic and scotopic conditions. This situation is a direct result of the lack of definition of the critical tasks and their sensitivity to an interruption of background adaptation. The Cherenkov radiation produced within the eye by relativistic electrons can be compared to light from external sources by the relationships: 1 rad approx. = 4.6 scotopic td-sec and 1 rad approx. = 0.55 photopic td sec. Based on these conversion factors, the following ...
1985-03-01
Energy Technology Data Exchange (ETDEWEB)
Radiation inactivation and sedimentation equilibrium analysis were used to determine the functional and physical size of the chicken hepatic membrane receptor that binds N-acetylglucosamine-terminated glycoproteins. Purified plasma membranes from chicken liver were irradiated with high energy electrons and assayed for 125I-agalactoorosomucoid binding. Increasing the dose of ionizing radiation resulted in a monoexponential decay in binding activity due to a progressive loss of binding sites. The molecular mass of the chicken lectin, determined in situ by target analysis, was 69,000 +/- 9,000 Da. When the same irradiated membranes were solubilized in Brij 58 and assayed, the binding protein exhibited a target size of 62,000 +/- 4,000 Da; in Triton X-100, the functional size of the receptor was 85,000 +/- 10,000 Da. Sedimentation equilibrium measurements of the purified binding protein yielded a lower limit molecular weight of 79,000 +/- 7,000. ...
1990-03-05
Electron-beam induced RAFT-graft polymerization of poly(acrylic acid) onto PVDF
Energy Technology Data Exchange (ETDEWEB)
This paper explores for the first time the post-radiation-induced-graft polymerization on solid substrate using reversible addition-fragmentation transfer (RAFT) mechanism. Radiation-induced graft polymerization onto polymers is a potentially interesting technique to create easily new materials from highly resistant polymers, e.g. surface graft polymerization of acrylic acid (AA) onto poly(vinylidene difluoride) (PVDF) improves its surface properties without losing its excellent mechanical properties. As a consequence of the radical nature of the polymerization processes it is difficult to control molecular weight of grafted chains, and therefore design and standardize the properties of the final product. RAFT polymerization is a suitable method to obtain monodisperse polymers. The ability of the RAFT agents to control the polymer chain length could be an interesting approach to improve the grafted polymers obtained by ...
2005-07-01
International Nuclear Information System (INIS)
Radiation chimeras in the early phase after bone marrow transplantation are a good model to study the efficiency of the body's nonspecific defense system represented by macrophages (M phi), polymorphonuclear cells (PMN), and NK cells. These cell types are present in large numbers in spleen and liver at that time, whereas the specific immune system represented by T and B cells is functionally deficient. We previously reported enhanced activities in vitro of M phi (and PMN) from recipient animals in an early phase after allogeneic bone marrow transfer. We here demonstrate that these activities result in enhanced spontaneous resistance against Listeria monocytogenes in vivo: CFU of L. monocytogenes in spleen and liver 48 h after infection were about 1 or 2 to 4 log steps less than in untreated control mice of donor or host haplotype. This enhanced resistance decreased over the 4-mo period after marrow transfer. Preactivated M phi were identified as the most important ...
Energy Technology Data Exchange (ETDEWEB)
Food-grade PVC and PVDC/PVC films containing 28.3% dioctyladipate (DOA) and 5.0% acetyltributylcitrate (ATBC) plasticizers, respectively, were brought into contact with olive oil and were irradiated with {gamma}-radiation [{sup 60}Co] at doses equal to 4 kGy and 9 kGy corresponding to `cold pasteurization`. Irradiation was carried out at 8-10 C and samples were subsequently stored at 4-5 C. Contaminated oil samples were analysed for DOA and ATBC at intervals between 7 h and 97 h of contact, using an indirect GC method. Identical non-irradiated (control) samples were also analysed for DOA and ATBC content. Results showed no statistically significant differences in migrated amounts of DOA and ATBC between irradiated and non-irradiated samples. Neither were differences observed between samples irradiated at 4 kGy and 9 kGy. This was supported by identical IR spectra recorded for irradiated and non-irradiated samples and leads to the conclusion that at such ...
1995-12-31
Systematics of average radiative width of heavy nuclides
Energy Technology Data Exchange (ETDEWEB)
Systematics of neutron capture radiative width were studied in the target element range from Th to Cm. Reduced radiative widths were analyzed with a simple radiative width formula based on E1 transition. Average radiative width is presented with the standard deviation of 15%. (author)
1999-03-01
Seismic qualification method of equipment for nuclear power plant
Energy Technology Data Exchange (ETDEWEB)
Safety related equipment installed in Korean Nuclear Power Plants are required to perform a safety function during and after a seismic event. To accomplish this safety function, they must be seismically qualified in accordance with the intent and requirements of the USNRC Reg. Guide 1.100 Rev. 02 and IEEE Std. 344-1987. This paper defines and summarizes acceptable criteria and procedures, based on the Korean experience, for seismic qualification of purchased equipment to be installed in a nuclear power plant. As such the paper is intended to be a concise reference by equipment designers, architectural engineering company and plant owners in uniform implementation of commitments to nuclear regulatory agencies such as the USNRC or Korea Institute of Nuclear Safety (KINS) relating to adequacy of seismic Category 1 equipment. Thus, the paper provides the methodologies which can be used for qualifying ...
1995-12-31
Coalfires related CO2 emissions and remote sensing
Energy Technology Data Exchange (ETDEWEB)
Subsurface and surface coalfires are a serious problem in many coal-producing countries. Combustion can occur within the coal seams (underground or surface), in piles of stored coal, or in spoil dumps at the surface. While consuming a non renewable energy source, coalfires promote several environmental problems. Among all GHGs that are emitted from coalfires, CO2 is the most significant because of its high quantity. In connection to this environmental problem, the core aim of the present research is to develop a hyperspectral remote sensing and radiative transfer based model that is able to estimate CO2 concentration (ppmv) from coalfires. Since 1960s remote sensing is being used as a tool to detect and monitoring coalfires. With time, remote sensing has proven a reliable tool to identify and monitor coalfires. In the present study multi-temporal, multi-sensor and multi-spectral thermal remote sensing data are being used to ...
2008-06-11
Coalfire related CO2 emissions and remote sensing
Energy Technology Data Exchange (ETDEWEB)
Subsurface and surface coalfires are a serious problem in many coal-producing countries. Combustion can occur within the coal seams (underground or surface), in piles of stored coal, or in spoil dumps at the surface. While consuming a non renewable energy source, coalfires promote several environmental problems. Among all GHGs that are emitted from coalfires, CO2 is the most significant because of its high quantity. In connection to this environmental problem, the core aim of the present research is to develop a hyperspectral remote sensing and radiative transfer based model that is able to estimate CO2 concentration (ppmv) from coalfires. Since 1960s remote sensing is being used as a tool to detect and monitoring coalfires. With time, remote sensing has proven a reliable tool to identify and monitor coalfires. In the present study multi-temporal, multi-sensor and multi-spectral thermal remote sensing data are being used to ...
2008-06-11
The great efficacy of personal and equipment assistance in reducing disability.
UK PubMed Central (United Kingdom)
OBJECTIVES: Personal and equipment assistance are common strategies to reduce disability. This study sought to determine how often assistance reduces or even completely resolves health-related difficulties...Full Text Available
1997-03-01
Standardization of rules for manufacturing normal electrical equipment for mining
Energy Technology Data Exchange (ETDEWEB)
Information is provided about standardization and unification of rules for manufacturing normal electrical equipment designed for operating in underground shafts when there is no danger of explosion of gas, dust or steam. An analysis is made of the requirements included in the CEMA standard and in the state standard.
1983-01-01
Schematic decision making process for air pollution control equipment for a coal conversion
Energy Technology Data Exchange (ETDEWEB)
A schematic diagram of the decision making process for air pollution control equipment for the conversion of a fossil-fired generating unit from oil to coal is presented and explained.
1981-01-01
Remote control monitoring - a review of the latest equipment
Energy Technology Data Exchange (ETDEWEB)
This article reviews briefly a range of the latest monitoring and controlling equipment for use in coal mines. This includes pressure transmitters, shale/coal discriminator, nucleonic bunker level indicator, automatic steering and monitoring system, oscilloscope/multimeter, and microprocessor based digital display controllers. 1 fig.
1988-01-01
International Nuclear Information System (INIS)
The guide describes a method acceptable to the NRC staff for complying with the Commission's regulations with regard to quality assurance requirements for installation, inspection, and testing of mechanical equipment and systems for water-cooled and high-temperature gas-cooled nuclear power plants.
Proposal for the award of a contract, without competitive tendering, for the replacement of lift machine room equipment and the installation of remote monitoring systems
2011-01-01
UK PubMed Central (United Kingdom)
A historical prospective mortality study was conducted on a cohort of 34 156 male members of a heavy construction equipment operators union with potential exposure to diesel exhaust emissions. This...Full Text Available
1985-07-01
Method for inhibiting fouling of petrochemical processing equipment
Energy Technology Data Exchange (ETDEWEB)
Method for inhibiting the formation of foulants on petrochemical equipment which involves adding to the petrochemical, during processing, a composition comprising a thiodipropionate and either a dialkyl acid phosphate ester or a dialkyl acid phosphite ester.
1980-10-07
Diesel equipment: is it safe to use underground
Energy Technology Data Exchange (ETDEWEB)
Research indicates that diesel equipment can be used safely in undergound coal mines provided that certain conditions prevail. These conditions are: the machines and engines are approved for underground use, an adequate maintenance and training program is in effect, an adequate monitoring system with proper instrumentation is used, and adequate ventilation is maintained.
1984-04-01
30 CFR 75.523-3 - Automatic emergency-parking brakes.
...Automatic emergency-parking brakes. (a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking...
2010-07-01
30 CFR 75.211 - Roof testing and scaling.
...d) A bar for taking down loose material shall be available in the working place or on all face equipment except haulage equipment. Bars provided for taking down loose material shall be of a length and design that will allow the removal of...
2010-07-01
30 CFR 75.1719-1 - Illumination in working places.
...position to receive material. (2) Self-loading haulage equipment used as a loading machine. In working places in which self-loading haulage equipment is operated to load material, the areas which...
2010-07-01
30 CFR 75.1403-8 - Criteria-Track haulage roads.
...Track haulage roads. (a) The speed at which haulage equipment is operated should be determined by the condition...elements of the track and the type and condition of the haulage equipment. (b) Track haulage roads should...
2009-07-01
Development of internal dose estimation software on radiation protection
International Nuclear Information System (INIS)
Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)
2008-10-01
NOZZLE WEAR DETECTION IN ABRASIVE WATERJET ...
... Accession Number : ADD330829. Title : NOZZLE WEAR DETECTION IN ABRASIVE WATERJET CUTTING SYSTEMS,. Corporate Author : ...
1990-03-01
Electron-Induced Luminescence and X-Ray Spectrometer (ELXS) System for Life Detection
The ELXS concept is a novel, portable, micro-instrument targeted for the detection of mineralogic
2002-01-01
Detection of the heavy Higgs boson at [gamma][gamma] colliders
Energy Technology Data Exchange (ETDEWEB)
We consider the possibility of detecting a heavy Higgs boson ([ital m][sub [ital H
1993-07-01
International Nuclear Information System (INIS)
Full text: Thermoluminescence (TL) is a phenomenon of light emission caused by heating a pre-irradiated material. When ionizing radiation hits a TL material, electrons are freed from some atoms and moved in the material, leaving behind 'holes' of positive charge. Subsequently when the TL material is heated, the electrons and the 'holes' re-combine, and release the extra energy in the form of light. The light intensity can be measured, and related to the amount of energy initially absorbed through exposure to the ionizing radiation. In nineteen sixties thermoluminescence dosimeters (TLD) became popular for dosimetric applications in view of their small size, sensitivity and accuracy. Consequently, in early seventies, several countries started adopting of TLD for personnel monitoring. The idea of introducing TLD to replace the then prevalent film dosimeter for personnel monitoring in India was mooted and successfully implemented by Dr. K G Vohra. ...
The state of the art: Appliances
Energy Technology Data Exchange (ETDEWEB)
This original volume of the Appliances Atlas includes discussion of residential appliances, commercial refrigeration and cooking, and office equipment. (The residential appliances section has since been updated in the E Source 1994 Residential Appliances Technology Atlas.) The commercial refrigeration section contains details on efficiency opportunities through load reduction and mechanical system improvements, while commercial cooking covers improvements to electric and gas fryers, griddles, ovens, cooktops, broilers, and steam equipment. The office equipment section offers discussion of trends and energy use of computers and their components, imaging technologies, and communication equipment. (Published under the former name, Competitek.)
1990-12-31
The History of the 2nd Ranger Company
... equipped and trained divisions. ... 4 The only division remotely considered combat ready was the 82nd Airborne Division. ...
2003-06-06
The Behavior of Water in Jet Fuels and the Clogging of ...
... values and unless special precautions and equipment are used, it would be very difficult to service and maintain operational jet-fuel systems with ...
1950-01-11
Plasma treatment of polymer dielectric films to improve capacitive energy storage
Demand for compact instrumentation, portable field equipment, and new electromagnetic weapons is
1994-01-01
MASER"'\\ - NASA Technical Report Server (NTRS)
cooling system designed to reject waste heat producedwithin the alternatorand. To other equipment operatingat much lower tempera- ...
National Aeronautics and Space Administration (NASA)
NASA's Glory spacecraft is equipped to survey and map aerosols in Earth's atmosphere during a mission marking the return to flight of the Taurus XL rocket.
2011-02-22
Fluidic-controlled automatic rabbit system
International Nuclear Information System (INIS)
... v. 15(10) p. 445-449. automation control equipment fluid flow fluidic control
FFTF progress highlights, winter 1975--1976
Milestones concerning equipment, reactor components, and testing and operations at the FFTF since July 1, 1975 are highlighted. (JWR)
1975-07-01
Development of equipment for irradiated nuclear fuel reprocessing plant
International Nuclear Information System (INIS)
2002 p. 9-10, 83-84 Russian Federation Glagolenko, Yu.V. Dzekun, EG
COST EVALUATION AND COST ESTIMATING FOR ...
... Accession Number : AD0833945. Title : COST EVALUATION AND COST ESTIMATING FOR SHIPBOARD ELECTRONIC EQUIPMENT. VOLUME II. ...
1967-04-01
CHLOROPICRIN LEAKAGE TEST OF THE M17 PROTECTIVE ...
... CHLOROPICRIN LEAKAGE TEST Of THE M17 PPRDOtCTIVE MASK EQUIPPED WITH DRINKING AND RESUSCITATION DEVICIS WORN BY ...
1965-10-01
Aviation Maintenance Safety Articles, January/February 1990
... These are abnormal and an indication of NAVAIRINST 13340.3 identifies these laboratories a possible breakdown in the fuel-handling equip- ...
1990-02-01
Analog Gun (Selection of Consumable Cartridge Materials).
... Descriptors : *Combustible cartridge cases, *Polymers, *Test equipment, *Patents, Combustion chambers, Breech mechanisms, Gas generating ...
1975-09-02
Abrasion problems in coal preparation
Energy Technology Data Exchange (ETDEWEB)
Lining of fused cast basalt tiles is recommended for various pieces of equipment constituting a coal preparation plant.
1981-01-01
Single Atom Detection With Optical Cavities
We present a thorough analysis of single atom detection using optical cavities. The large set of parameters that influence the signal-to-noise ratio for cavity detection is considered, with an emphasis on detunings, probe power, cavity finesse and photon detection schemes. Real device operating restrictions for single photon counting modules and standard photodiodes are included in our discussion, with heterodyne detection emerging as the clearly favourable technique, particularly for detuned detection at high power.
2008-01-01
Explosives detection: the problem and prospects
Energy Technology Data Exchange (ETDEWEB)
The history of explosives vapor detection includes almost every detection strategy known to man. Initial attempts to utilize these techniques were dismal failures. However, with the development of the Electron Capture Detector (ECD), the first promising detection of explosives vapors became possible. The present commercial explosives detectors detect the higher vapor pressure materials but not the whole spectrum. This paper describes the basic properties of explosives molecules and our research to utilize these properties for increased detection sensitivity.
1984-01-01
The evaluation of risks from radiation
International Nuclear Information System (INIS)
German translation of the publication 'The evaluation of risks from radiation' published in 1965 by the International Commission on Radiological Protection. In a survey, genetic and somatic risks from radiation are presented and explained. (HP).
1977-01-01
International Nuclear Information System (INIS)
Portuguese Sep-Oct 1996 p. 571 Brazil Campos, Patricia Sao Paulo
Role of Mast Cells in Early and Delayed Radiation Injury in Rat Intestine
... mast cell staining; ref. 16). The severity of structural radiation injury was assessed using a histopathological radiation injury score ... ...
The principles of radionuclide excitation of X-ray fluorescence radiation and its application in
1972-01-01
International Nuclear Information System (INIS)
This book gives an overview of the entire field of radiation protection with the subject areas radioactivity, X-rays, UV radiation, laser beams and high-frequency electromagnetic fields. It deals graphically with the most important physical notions, the incidence, origin, properties and biological effects of types of radiation, administrative and practical protection measures and the code of rules governing them. Apart from fundamentals of radiation protection the emphasis on the following: natural radiation exposure, radiation exposure to radon, disaster relief plans in the environment of nuclear plant, the precautionary radiation protection system evolved after Chernobyl, radiation exposure through UV radiation devices, radio, RF communication, radar, microwave ovens and high-voltage transmission ...
1993-01-01
Maintenance of energy systems by means of Internet; Energiesystemen onderhouden met Internet
Energy Technology Data Exchange (ETDEWEB)
Asean Brown Boveri (ABB) developed Glass (Global access for service and support), a monitoring system for the remote control and management of ABB supplied equipment and other equipment through the Internet. Glass can be applied for many different systems, e.g. automated substations of electric power distribution systems or train equipment
1999-04-01
International Nuclear Information System (INIS)
The gamma scanning system which is installed in IMEF is the equipment obtaining the gamma ray spectrum from irradiated fuels. This equipment could afford the useful data relating spent fuels like as burn-up measurements. We describe the specifications of the equipment and its accessories, and also described its operation procedure so that an operator can use this report as the operation procedure. (author). 1 tab., 11 figs., 11 refs.
1989-09-10
Xeroradiography and computed radiography comparative study on diagnosis for breast cancer
Energy Technology Data Exchange (ETDEWEB)
Xeroradiography (XR) was retrospectively compared with a newly developed computed radiography (FCR) for diagnostic availability for breast cancer. FCR provides with the image processed by a computer. Subjects were 65 breast cancer patients for XR and 51 for FCR. Both methods were performed preoperatively. No significant difference was observed in distribution of age between the two groups but the average tumor size in XR group was larger than that in FCR group. Tumor shadow appeared in 44 of 65 xeromammograms (67.7%) and in 34 of 51 computed radiograms (66.7%). Microcalcification was detected in 27 of 65 xeromammograms (41.5%) and in 21 of 51 computed radiograms (41.2%). Consequently, diagnosis of breast cancer could be achieved in 47 of 65 patients (72.3%, established: 39, suspective: 8) through XR and in 41 of 51 (80.4%, established: 33, suspected: 8) through FCR. Thus FCR is thought to be more useful for breast cancer because it not only offers good diagnostic ...
1990-04-01
Xeroradiography and computed radiography comparative study on diagnosis for breast cancer
International Nuclear Information System (INIS)
Xeroradiography (XR) was retrospectively compared with a newly developed computed radiography (FCR) for diagnostic availability for breast cancer. FCR provides with the image processed by a computer. Subjects were 65 breast cancer patients for XR and 51 for FCR. Both methods were performed preoperatively. No significant difference was observed in distribution of age between the two groups but the average tumor size in XR group was larger than that in FCR group. Tumor shadow appeared in 44 of 65 xeromammograms (67.7%) and in 34 of 51 computed radiograms (66.7%). Microcalcification was detected in 27 of 65 xeromammograms (41.5%) and in 21 of 51 computed radiograms (41.2%). Consequently, diagnosis of breast cancer could be achieved in 47 of 65 patients (72.3%, established: 39, suspective: 8) through XR and in 41 of 51 (80.4%, established: 33, suspected: 8) through FCR. Thus FCR is thought to be more useful for breast cancer because it not only offers good diagnostic ...
1990-01-01
XPS/AES Study of Electrical and Chemical Properties of Pd/SiC Interface
Silicon carbide (SiC) based electronic devices are of great importance for applications under the condition of high temperature, high power and high radiation. Schottky diodes of Palladium/SiC are good candidates for hydrogen and hydrocarbon gas sensors at elevated temperature. The detection sensibility of the diodes has been found heavily temperature dependent. In this work, the electrical and chemical properties of Pd/SiC Schottky contacts were studied by XPS and AES at different annealing temperatures. Schottky diodes were made by depositing ultra-thin palladium films onto a silicon carbide substrate. No significant change in the Schottky barrier height of the Pd/SiC contact was found in the temperature range of 300-673K. Palladium diffusion into SiC and the formation of palladium silicides were observed at room temperature and became significant at 300^oC and higher temperature. The mechanism of diffusion and reaction at the Pd/SiC ...
1997-11-01
X-Ray Fluorescence in Research on the Cultural Heritage
Energy Technology Data Exchange (ETDEWEB)
Radionuclide X-ray fluorescence analysis is a method, which has many advantages for analysing various historic artefacts, as it is relatively cheap, sensitive and non-destructive, and it allows measurements in-situ. However, this analysis has also certain limitations especially concerning sensitivity to chemical elements only, irrespective of the compounds or chemical forms in which these elements have been bonded. In addition, light elements emitting very soft X-rays cannot be measured, and in order to detect a wide range of elements, it is necessary to carry out repeated measurements with different radiation sources. Despite these limitations, valuable information can be obtained about the composition of historic materials and data about the origin and age of these artefacts can be derived. Analyses of wall paintings, ancient metal sculptures or other objects of art provide the basis for historic considerations documented in our results for ...
2001-09-15
X-Ray Fluorescence in Research on the Cultural Heritage
International Nuclear Information System (INIS)
Radionuclide X-ray fluorescence analysis is a method, which has many advantages for analysing various historic artefacts, as it is relatively cheap, sensitive and non-destructive, and it allows measurements in-situ. However, this analysis has also certain limitations especially concerning sensitivity to chemical elements only, irrespective of the compounds or chemical forms in which these elements have been bonded. In addition, light elements emitting very soft X-rays cannot be measured, and in order to detect a wide range of elements, it is necessary to carry out repeated measurements with different radiation sources. Despite these limitations, valuable information can be obtained about the composition of historic materials and data about the origin and age of these artefacts can be derived. Analyses of wall paintings, ancient metal sculptures or other objects of art provide the basis for historic considerations documented in our results for ...
2001-09-01
Verification of electron beam therapy with storage phosphor images: Precision of field placement
Energy Technology Data Exchange (ETDEWEB)
Portal verification images were generated from the photon contamination in electron beams produced by a linear accelerator during treatment of patients receiving high-energy electron radiation therapy (8-14 MeV). An experimental storage phosphor system was used to record the images and display them on laser-printed film. Images were obtained from four or more treatment fractions from 21 cases of head and neck cancer. Precision in field placement was estimated by determining the position of a selected anatomic landmark relative to the center of the field for each series of images. The average standard deviation in the field-position measurements was 3.8 mm. Several procedural problems were also detected and corrected after review of the verification images. The results indicate that the emphasis placed on monitoring and control of field-positioning error in high-energy electron treatments should be similar to the emphasis placed on this aspect ...
1990-04-01
International Nuclear Information System (INIS)
Fission track analysis (FTA) technique for the determination of "2"3"9Pu excreted through urine has been standardized using blank samples, tracer and "2"3"9Pu spikes. Double stage anion exchange separation protocol has been applied and an average radiochemical recovery of "2"3"9Pu of 18% was obtained. An average track registration efficiency of 11 tracks per #mu#Bq of "2"3"9Pu, irradiated to 0.35x10"1"7 neutron fluence was established. Reagent blank urine samples from 11 controlled subjects were analyzed by FTA and an average of 149#+-#14 tracks was obtained. Minimum detectable activity of 34 #mu#Bq L"-"1 of urine sample was obtained and will be useful for monitoring chronic exposure cases handling MOX fuel.
2011-07-01
The infrared-dominated jet of 3C401
We present a Hubble Space Telescope image of the FRII radio galaxy 3C 401, obtained at 1.6 microns with the NICMOS camera in which we identify the infrared counterpart of the brightest region of the radio jet. The jet has a complex radio structure and brightens where bending occurs, most likely as a result of relativistic beaming. We analyze archival data in the radio, optical and X-ray bands and we derive its spectral energy distribution. Differently from all of the previously known optical extragalactic jets, the jet in 3C401 is not detected in the X-rays even in a long 48ksec X-ray Chandra exposure and the infrared emission dominates the overall SED. We propose that the dominant radiation mechanism of this jet is synchrotron. The low X-ray emission is then caused by two different effects: i) the lack of any strong external photon field and ii) the shape of the electron distribution. This affects the location of the synchrotron peak in the ...
2005-01-01
Suzaku and Optical Spectroscopic Observations of SS 433 in the 2006 April Multiwavelength Campaign
We report results of the 2006 April multi-wavelengths campaign of SS 433, focusing on X-ray data observed with Suzaku at two orbital phases (in- and out-of- eclipse) and simultaneous optical spectroscopic observations. By analyzing the Fe25 K_alpha lines originating from the jets, we detect rapid variability of the Doppler shifts, dz/dt ~ 0.019/0.33 day^-1, which is larger than those expected from the precession and/or nodding motion. This phenomenon probably corresponding to "jitter" motions observed for the first time in X-rays, for which significant variability both in the jet angle and intrinsic speed is required. From the time lag of optical Doppler curves from those of X-rays, we estimate the distance of the optical jets from the base to be ~(3-4) \\times 10^14 cm. Based on the radiatively cooling jet model, we determine the innermost temperature of the jets to be T_0 = 13 +/- 2 keV and 16 +/- 3 keV (the average of the blue and red jets) ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
High-spin states in the neutron-rich nuclei {sup 172,173}Yb have been populated in a {sup 170}Er({sup 7}Li,(p,d,t)xn) incomplete-fusion reaction and the emitted {gamma}-radiation was detected with the GASP array. The signature partners of the 7/2{sup +}[633] rotational band of the odd-N {sup 173}Yb isotope have been newly established and were observed up to spin values of (45/2{sup +}) and (43/2{sup +}), respectively. The ground-state band of the even-even nucleus {sup 172}Yb has been observed up to a spin value of (22{sup +}). No band crossings were found in these bands. To explain this observation, it is proposed that the static pair field is absent, considering that the neutron odd-even mass differences reach for these nuclei very small values and that the band crossing is absent in cranked shell modell calculations without pairing. The results indicate, however, that strong dynamic correlations are still present. (orig.)
2005-10-01
Skeletal remodeling dynamics: New approaches with imaging instrumentation
Energy Technology Data Exchange (ETDEWEB)
This report of progress and future objectives timetable is based on an included schematic of goals and objectives and the project abstract which is included as Appendix 1. Five matters are summarized in the order of (1) novel methods of calcified bone confocal microscopy and reconstruction image analysis of decalcified beagle and human cortical bone serial sections, (2) macroscopic cross-correlation of beagle and human cortical and cancellous bone fractions with CT analysis, (3) guidance to the most radiobiologically important skeletal regions of interest with the just completed {sup 90}Sr bone tumor map from life time beagle studies, (4) deposition patterns of radioactive agents that participate in apatite crystal nucleation processes in bone and leave radiation-excited electrons trapped in bone mineral, and (5) the budget period timetable. The discovery that beta particles from {sup 166}Ho (T{sub {1/2}} =26 hr, {beta}{sub max} = 1.8 MeV) phosphonic acid bone ...
1991-12-01
Energy Technology Data Exchange (ETDEWEB)
Strain-induced crystallization of crosslinked natural rubber (NR) and its synthetic analogue, cis-1,4-polyisoprene (IR), both mixed with various amounts of stearic acid (SA), were investigated by time-resolved X-ray diffraction using a powerful synchrotron radiation source and simultaneous mechanical (tensile) measurement. No acceleration or retardation was observed on NR in spite of the increase of SA amount. Even the SA-free IR crystallized upon stretching, and the overall crystallization behavior of IR shifted to the larger strain ratio with increasing SA content. No difference due to the SA was detected in the deformation of crystal lattice by stress for both NR and IR. These results suggested that the extended network chains are effective for the initiation of crystallization upon stretching, while the role of SA is trivial. These behaviors are much different from their crystallization at low temperature by standing, where SA acts as a ...
2007-01-01
Radiation-induced mutations at mouse hemoglobin loci
International Nuclear Information System (INIS)
In experiments designed to detect new mutations affecting hemoglobin, we irradiated the male or female parent in reciprocal crosses of two mouse strains that differ in alleles at the hemoglobin (Hba, Hbb) loci as well as at five other specific loci. Offspring were analyzed for hemoglobin properties (electrophoretic pattern, solubility, crystal pattern), serum albumin differences, erythrocyte lysis, reticulocyte count, and external appearance. Five hemoglobin variants were found among the mutants. In three, the genetic contribution from the irradiated father was not expressed with regard to the #alpha#-chain; one carried a tandem duplication (the first known case in the mouse) involving Hbb; and one probably resulted from double nondisjunction of chromosome 7. The finding that major chromosome aberratios can mimic hemoglobin mutations indicates the need, in similar experiments, to follow F_1 screening with thorough cytogenetic analysis. The variants in which there ...
Measurement of redshifted 21-cm emission from neutral hydrogen promises to be the most effective method for studying the reionisation history of hydrogen and, indirectly, the first galaxies. These studies will be limited not by raw sensitivity to the signal, but rather, by bright foreground radiation from Galactic and extragalactic radio sources and the Galactic continuum. In addition, leakage due to gain errors and non-ideal feeds conspire to further contaminate low-frequency radio obsevations. This leakage leads to a portion of the complex linear polarisation signal finding its way into Stokes I, and inhibits the detection of the non-polarised cosmological signal from the epoch of reionisation. In this work, we show that rotation measure synthesis can be used to recover the signature of cosmic hydrogen reionisation in the presence of contamination by polarised foregrounds. To achieve this, we apply the rotation measure synthesis technique to ...
2010-01-01
INTRINSIC DOSIMETRY: A POTENTIAL NEW TOOL FOR NUCLEAR FORENSICS INVESTIGATIONS
International Nuclear Information System (INIS)
Thermoluminescence (TL) dosimetry was used to measure dose effects on the raw stock material of borosilicate container glass from different geographical locations. Effects were studied at times up to 60 days post-irradiation at doses from 0.15 to 20 Gy. The minimum detectable dose using this technique was estimated to be 0.15 Gy which is roughly equivalent to a 24 hr irradiation 1 cm from a 50 ng source of 60Co. Two peaks were identified in the TL glow curve, a relatively unstable peak around 125 C and a more stable peak around 225 C. Differences in TL glow curve shape and intensity were also observed for the glasses from different geographical origins. We investigate radiation induced defects in glass to further develop the technique of intrinsic dosimetry - the measurement of the total absorbed dose received by the walls of a container holding radioactive material. Intrinsic dosimetry is intended to be used as an interrogation tool to provide ...
2010-07-11
Increasing the speed and complexity of semiconductor integrated circuits requires advanced processes that put extreme constraints on the level of metal contamination allowed on the surfaces of silicon wafers. Such contamination degrades the performance of the ultrathin SiO sub 2 gate dielectrics that form the heart of the individual transistors. Ultimately, reliability and yield are reduced to levels that must be improved before new processes can be put into production. It should be noted that much of this metal contamination occurs during the wet chemical etching and rinsing steps required for the manufacture of integrated circuits and industry is actively developing new processes that have already brought the metal contamination to levels beyond the measurement capabilities of conventional analytical techniques. The measurement of these extremely low contamination levels has required the use of synchrotron radiation total reflection X-ray fluorescence (SR-TXRF) ...
2003-01-01
HD 75289Ab revisited - Searching for starlight reflected from a hot Jupiter
Aims. We attempt to detect starlight reflected from a hot Jupiter, orbiting the main-sequence star HD 75289Ab. We report a revised analysis of observations of this planetary system presented previously by another research group. Methods. We analyse high-precision, high-resolution spectra, collected over four nights using UVES at the VLT/UT2, by way of data synthesis. We try to interpret our data using different atmospheric models for hot Jupiters. Results. We do not find any evidence for reflected light, and, therefore, establish revised upper limits to the planet-to-star flux ratio at the 99.9% significance level. At high orbital inclinations, where the best sensitivity is attained, we can limit the relative reflected radiation to be less than e = 6.7 x 10-5 assuming a grey albedo, and e = 8.3 x 10-5 assuming an Class IV function, respectively. This implies a geometric albedo smaller than p = 0.46 and p = 0.57, for the grey albedo and the ...
2008-01-01
GaAs Blocked-Impurity-Band Detectors for Far-Infrared Astronomy
Energy Technology Data Exchange (ETDEWEB)
High-purity and doped GaAs films have been grown by Liquid-phase epitaxy (LPE) for development of a blocked impurity band (BIB) detector for far-infrared radiation. The film growth process developed has resulted in the capability to grow GaAs with a net active impurity concentration below 1 x 10{sup 13} cm{sup -3}, ideal for the blocking layer of the BIB detector. The growth of n-type LPE GaAs films with donor concentrations below the metal-insulator transition, as required for the absorbing layer of a BIB detector, has been achieved. The control of the donor concentration, however, was found to be insufficient for detector production. The growth by LPE of a high-purity film onto a commercially grown vapor-phase epitaxial (VPE) n-type GaAs doped absorbing layer resulted in a BIB device that showed a significant reduction in the low-temperature dark current compared to the absorbing layer only. Extended optical response was not detected, most ...
2004-12-21
International Nuclear Information System (INIS)
The details and principles of an apparatus built for measurements of fluorescence quantum yields and cascade-free lifetimes of open-shell cations are reported. These rely on the detection of coincidences between energy selected photo-electrons and undispersed photons. The results of such measurements for CO"+_2,COS"+,CS"+_2 and N_2O"+ in selected vibrational levels of their excited states are presented. Non-unity fluorescence quantum yields are found for some vibronic levels of CO"+_2(B), COS"+(A), N_2O"+(A) and a non-exponential decay is observed for CS"+_2(B). The data yield the following values for the radiative lifetimes: CO"+_2(A) 124 +- 6 ns,CO"+_2(B) 140 +- 7 ns, COS"+(A) 550 +- 50 ns and N_2O"+(A) 240 +- 12 ns. (orig.).
1980-10-01
International Nuclear Information System (INIS)
New physical objects, ispalators based on free soap films, exhibit persistent flows of the soap solution in open and closed volumes in air with additions of gases of the C_8F_1_8 type (p = 20 Torr) at temperature drops on the films of the order of tenths and hundredths of kelvin. The flows move continuously at a velocity of 5 - 20 cm s"-"1. It is found that the parts of an inclined ispalator film show anomalous behaviour upon heating: their weight increases and they move downward over the film, whereas the unheated parts of the film move upward. Continuous radial vortex flows accompanied by the formation and washing of the regions of a thin black film are observed on circular films in closed volumes upon their uniform external cooling by evaporating water for 5 - 10 hours. The rapid flows make film ispalators the efficient heat carriers, which operate at small temperature drops (tenths and hundredths of kelvin) and surpass copper in the amount of thermal energy being transferred. The ...
2002-05-31
Correction for loss of track density due to overlapping track on SSNTD
Energy Technology Data Exchange (ETDEWEB)
Solid state nuclear track detectors (SSNTD) record radiation in the form of tracks. In the case of high track density, however, it is not always possible to distinguish each track separately. The track density might then be underestimated unless the loss of track number due to overlapping is compensated. An elaborated 'erosion' or curve fitting process is applied usually, for the separation of the overlapping tracks, to automatic track counting systems. This paper shows a much simpler correction method which was developed by the analogy of the correction equation for the dead time of GM counters. From a set of about 10 data obtained from high track density detectors, the equation for SSNTD can be determined by a least square fitting. Once the equation is found, true track density could be derived easily without any help of complex image processing or calculation, such as the erosion or curve fitting. This method also provides the privilege of ...
1990-06-01
Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the art
Energy Technology Data Exchange (ETDEWEB)
The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal equilibrium, homogeneous plasma, thin ...
2010-01-15
Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the art
International Nuclear Information System (INIS)
The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal equilibrium, homogeneous plasma, thin ...
2010-01-01
An evaluation of low-dose single-slice helical CT in pulmonary CT scan
International Nuclear Information System (INIS)
Objective: To investigate the feasibility of low-dose single-slice helical CT in pulmonary CT scan and evaluate the clinical application. Methods: Thirteen cases were selected out of 132 cases, in which low-dose (50mAs) single-slice helical CT scan of chest was performed. This set of cases included 7 cases of multiple metastatic nodules; 3 of solitary pulmonary, nodule; and 3 of pulmonary patchy lesions. Regular dose (170mAs) CT scan was also performed on all those patients. The regular dose and low dose CT scan were compared on sensitivity of detecting the lesions; the performance in demonstrating the details of the abnormalities; and the capability of revealing the segmental bronchi as well. Results: The same number and size of the pulmonary nodules were revealed with scan modalities loaded with different doses. No significant difference in demonstrating the details of the nodules and the segmental bronchi was found between both modalities (#chi#"2=0.123-3.39, ...
2006-04-01
An aerial radiological survey of the Hanford Site and surrounding area, Richland, Washington
International Nuclear Information System (INIS)
An aerial radiological survey was conducted over the Department of Energy's Hanford Site near Richland, Washington, during the period 5 July through 26 August 1988. The survey was expanded, and additional flights were conducted to the east of the site and along the banks of the Columbia River down to McNary Dam near Umatilla. The survey was flown at altitude of 61 meters (200 feet) by a helicopter containing 17 liters (eight 2 in. x 4 in. x 16 in.) of sodium iodide detectors. Gamma ray data were collected over the survey area by flying north-south lines spaced 122 meters (400 feet) apart. The processed data indicated that detected radioisotopes and their associated gamma ray exposure rates were generally consistent with those expected from normal background emitters and man-made fission/activation products resulting from activities at the site. External exposure rates were generally 10 microroentgens per hour (#mu#R/h) with some operating areas over 1000 #mu#R/h. ...
1990-09-16
A magnetically levitated electrode ionization chamber of the noncontact measurement type
Energy Technology Data Exchange (ETDEWEB)
A new type of ionization chamber with levitated electrode has been developed. In this ionization chamber, an ion-collection electrode levitates in the air without getting any physical support from the insulator. The electrode is charged by an electrostatic charger without physical contact. The charge of the electrode is read out at a Faraday cage periodically at a given time interval without physical contact. Because its electrode levitates, the ionization chamber produces no background current caused by leaks or piezo current. In addition, as the charging of its electrode and the read-out of its charge are carried out without physical contact, no irregular charge or contact potential difference due to the chattering between electrode and contact point occurs. Through experiments, it was found that this ionization chamber was able to measure the {gamma}-ray dose such as the environmental radiation with a high degree of sensitivity. The minimum ...
2002-04-01
A clinical perspective on common forms of acquired heterotopic ossification
Energy Technology Data Exchange (ETDEWEB)
The clinical courses of heterotopic ossification (HO) as a consequence of trauma and central nervous system insults have many similarities as well as dissimilarities. Detection is commonly noted at two months. The incidence of clinically significant HO is 10%-20%. Approximately 10% of the HO is massive and causes severe restriction in joint motion or ankylosis. The most common sign and symptom are decreased range of motion and pain. The locations are the proximal limbs and joints. Sites of HO about a joint may vary according to the etiology of the HO. Roentgenographic evolution of HO occurs during a six-month period in the majority of patients. Treatment modalities include diphosphonates, indomethacin, radiation, range of motion exercises, and surgical excision. Surgical timing differs according to etiology: traumatic HO may be resected at six months; spinal cord injury HO is excised at one year; and traumatic brain injury HO is removed at 1.5 ...
1991-02-01
A clinical perspective on common forms of acquired heterotopic ossification
International Nuclear Information System (INIS)
The clinical courses of heterotopic ossification (HO) as a consequence of trauma and central nervous system insults have many similarities as well as dissimilarities. Detection is commonly noted at two months. The incidence of clinically significant HO is 10%-20%. Approximately 10% of the HO is massive and causes severe restriction in joint motion or ankylosis. The most common sign and symptom are decreased range of motion and pain. The locations are the proximal limbs and joints. Sites of HO about a joint may vary according to the etiology of the HO. Roentgenographic evolution of HO occurs during a six-month period in the majority of patients. Treatment modalities include diphosphonates, indomethacin, radiation, range of motion exercises, and surgical excision. Surgical timing differs according to etiology: traumatic HO may be resected at six months; spinal cord injury HO is excised at one year; and traumatic brain injury HO is removed at 1.5 ...
Energy Technology Data Exchange (ETDEWEB)
Diffuse {gamma}-ray emission produced by the interaction of cosmic-ray particles with matter and radiation in the Galaxy can be used to probe the distribution of cosmic rays and their sources in different regions of the Galaxy. With its large field of view and long observation time, the Milagro Gamma Ray Observatory is an ideal instrument for surveying large regions of the Northern Hemisphere sky and for detecting diffuse {gamma}-ray emission at very high energies. Here, the spatial distribution and the flux of the diffuse {gamma}-ray emission in the TeV energy range with a median energy of 15 TeV for Galactic longitudes between 30{sup o} and 110{sup o} and between 136{sup o} and 216{sup o} and for Galactic latitudes between -10{sup o} and 10{sup o} are determined. The measured fluxes are consistent with predictions of the GALPROP model everywhere except for the Cygnus region (l {element_of} [65{sup o}, 85{sup o}]). For the Cygnus region, the ...
2008-05-14
Terra Nova tow-out poised as next East Coast event
Energy Technology Data Exchange (ETDEWEB)
This spring, Newfoundland will send off a floating production, storage and offloading (FPSO) vessel to the offshore Terra Nova field. The Terra Nova will proceed southeast through Bull Arm, then northeast out of Trinity Bay, then heads southeast to the Jeanne d'Arc Basin on the Grand Banks. The Terra Nova is expected to produce 115,000 barrels of oil per day for six years, when it reaches full capacity. The consortium, headed by Petro-Canada as senior ownership partner and operator, built an environment protection program into every aspect of the project. Some of the features of the environment protection program include glory holes excavated on the ocean floor for the protection of production equipment from icebergs, to a flare stack on the platform, which has four legs to provide stability in rough seas. The FPSO was designed to withstand sea ice, icebergs, and severe winter storms. Flow lines are also protected, and in the event that a line is damaged, ...
2001-01-15
Measurements of radon concentration levels in drinking water at urban area of Curitiba, Brazil
International Nuclear Information System (INIS)
Current work presents the results of more than 100 measurements of 222Rn activity in drinking water collected at artesian bores at Curitiba region during the period of 2008 - 2009. The measurements were performed at the Laboratory of Applied Nuclear Physics of the Federal University of Technology in cooperation with the Nuclear Technology Development Center (CDTN) of Brazilian Nuclear Energy Committee (CNEN). Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specific kit of glass vessels Aqua KIT through the air pump. The equipment was adjusted with air flow of 0.5 L/min. The 222Rn concentration levels were detected and analyzed by the computer every 10 minutes using the software DataEXPERT by GENITRON Instruments. Collected average levels of 222Rn concentration were processed taking into account the volume of water sample and its temperature, atmospheric pressure and the total volume of the air in the ...
Energy Technology Data Exchange (ETDEWEB)
Free-electron laser (FEL) experiments have been conducted with the 38-MeV L-band electron linac at the Institute of Scientific and Industrial Research, Osaka University. It is a 1.3 GHz RF linac with a thermoionic gun, and equipped with two 12th and one 6th sub-harmonic prebunchers for producing the high-intensity single-bunch beam with a charge up to 67 nC/bunch. For oscillation experiments of FEL, the gun is replaced with that with a smaller cathode area in order to reduce the emittance of the beam. The normalized emittance has been measured to be 200 {pi} mm-mrad. The linac is operated in the long-pulse mode and one of the 12th sub-harmonic bunchers and the 6th sub-harmonic buncher are operated, so that the time duration of the macropulse is 4 {mu}s and the spacing between micropulses is 9.2 ns. The length of the micropulse is 30-40 ps and the charge in each micropulse is 2 nC. The electron beam from the linac is transported to a wiggler which has the period ...
1995-12-31
DOE assay methods used for characterization of contact-handled transuranic waste
International Nuclear Information System (INIS)
US Department of Energy methods used for characterization of contact-handled transuranic (CH-TRU) waste prior to shipment to the Waste Isolation Pilot Plant (WIPP) are described and listed by contractor site. The methods described are part of the certification process. All CH-TRU waste must be assayed for determination of fissile material content and decay heat values prior to shipment and prior to storage on-site. Both nondestructive assay (NDA) and destructive assay methods are discussed, and new NDA developments such as passive-action neutron (PAN) crate counter improvements and neutron imaging are detailed. Specifically addressed are assay method physics; applicability to CH-TRU wastes; calibration standards and implementation; operator training requirements and practices; assay procedures; assay precision, bias, and limit of detection; and assay limitation. While PAN is a new technique and does not yet have established American Society for Testing and ...
DOE assay methods used for characterization of contact-handled transuranic waste
Energy Technology Data Exchange (ETDEWEB)
US Department of Energy methods used for characterization of contact-handled transuranic (CH-TRU) waste prior to shipment to the Waste Isolation Pilot Plant (WIPP) are described and listed by contractor site. The methods described are part of the certification process. All CH-TRU waste must be assayed for determination of fissile material content and decay heat values prior to shipment and prior to storage on-site. Both nondestructive assay (NDA) and destructive assay methods are discussed, and new NDA developments such as passive-action neutron (PAN) crate counter improvements and neutron imaging are detailed. Specifically addressed are assay method physics; applicability to CH-TRU wastes; calibration standards and implementation; operator training requirements and practices; assay procedures; assay precision, bias, and limit of detection; and assay limitation. While PAN is a new technique and does not yet have established American Society for Testing and ...
1991-08-01
The utilization of non-destructive method for in-service inspections in nuclear power components
International Nuclear Information System (INIS)
To ensure safe and reliable power production nuclear power plants must be operated at high level. Non destructive in-service inspections are inseparable part of the effort. Non destructive in-service inspections are essential on the ground of degradation mechanisms existence in nuclear power components. Degradation processes are constituent of operation of each industrial installation including nuclear power plants. Mission of non-destructive testing is degradation detection, closer characterization of its parameters (dimensions) and to supply as much information as possible to nuclear power plant operator. Eddy current testing method can be assigned to surface - volumetric methods. Method enables inspection of electrically conductive materials. It is particularly suitable for inspection of non-ferromagnetic materials like austenitic stainless steel and brass. The method is used for detection of stress corrosion cracking, pitting corrosion or ...
2006-01-01
Simulation and Observation of Acoustic-Gravity Waves in the Ionosphere
Atmospheric and ionospheric perturbations associated with the acoustic-gravity waves (AGW) with typical frequencies of a few hertz -millihertz are considered. These events may be caused by the influence from space and atmosphere as well as by oscillations of the Earth surface and other near-surface phenomena. The surface sources include long-period oscillations of the Earth's surface, earthquakes, explosions, thermal heating, seisches and tsunami waves. The wavelike phenomena manifest themself as travelling disturbances of air (in the atmosphere) and of electron density (in the ionosphere). Travelling ionospheric disturbances (TIDs) are well detected by radio physical methods. AGW generation by near-surface sources is modeled by the numerical solution of the equation of geophysical fluid dynamics for different sources in two-dimensional non-linear dissipative compressible atmosphere. The numerical calculations are based on the FCT (Flux Corrected Transport) ...
2010-01-01
A vibration amplification device for the seismic margins test of NPP equipment
International Nuclear Information System (INIS)
This paper describes new test methodologies to obtain data used to evaluate the ultimate seismic strength of Nuclear Power Plant (NPP) equipment related to nuclear safety. The paper first reviews existing equipment seismic test data from the viewpoint of the evaluation of their ultimate seismic strength and/or seismic design margins, and extracts the issues in the existing data with regard to their applicability to the evaluation. Then, the paper proposes new test methodologies for the equipment to evaluate their ultimate seismic strength. The test methodology of the equipment employs a vibration amplification system to a shaking table and enhances its applicable maximum acceleration up to 6g. The test methodology herein is cost effective for obtaining test data that is indispensable for evaluating proper seismic margins of NPPs. (author)
2003-09-15
THE ENVIRONMENTAL MANAGEMENT AND CO-ORDINATION ACT, 1999
Subject to the provisions of the Radiation Protection Act, the Authority, on the advice of ...(f) in collaboration with the Radiation Protection Board, conduct an ionising radiation monitoring programme and ...or document kept under the control of the Radiation Protection Board.
Application of gamma radiation
International Nuclear Information System (INIS)
Described and discussed in this paper are radiation processes and their advantages over the conventional techniques. Radiation sterilization of medical products, food irradiation, wood plastic composites, and radiation treatment of sewage and waste waters are presented. The Philippine experience in using these technologies, its problems and barriers are also given. (ELC).
1985-12-10
Energy Technology Data Exchange (ETDEWEB)
The Institute of Energetic and Nuclear Research - IPEN is a research and development institution, located in a densely populated area, in the city of Sao Paulo. The nuclear fuel cycle was developed from the Yellow Cake to the enrichment and reconversion at IPEN. After this phase, all the technology was transferred to private enterprises and to the Brazilian Navy (CTM/SP). Some plants of the fuel cycle were at semi-industrial level, with a production over 20 kg/h. As a research institute, IPEN accomplished its function of the fuel cycle, developing and transferring technology. With the necessity of space for the implementation of new projects, the uranium hexafluoride (UF{sub 6}) production plant was chosen, since it had been idle for many years and presented potential leaking risks, which could cause environmental aggression and serious accidents. This plant decommission required accurate planning, as this work had not been carried out in Brazil before, for this type of facility, and ...
2008-07-01
The high-sensitive magnetic levitated electrode ionization chamber of the noncontacting type
Energy Technology Data Exchange (ETDEWEB)
There are two types of ionization chamber using magnetically levitated electrode: one is that by Tanaka et al. and the other, by authors'. The latter lacks the sensitivity relative to the former and thereby to solve the problem, authors made an improvement so that the electrode charge could be readout by noncontact after the leviated electrode was electrified by noncontact for an interval. This new type ionization chamber made it possible to measure the quite low dose radiation with stability and high sensitivity. Actually, the electrode was suspended by the teflon thread fixed on the steel cup levitated magnetically in the ionization chamber of which wall was covered by Al and equipped with an electrostatic charger for the electrode by noncontact. After measurement, the electrode was moved in the Faraday cage placed under the chamber to readout the voltage. For operation conditions of the apparatus, observation was done on the ...
1999-09-01
Review of passive heat transfer augmentation techniques
Energy Technology Data Exchange (ETDEWEB)
Heat transfer augmentation techniques (passive, active or a combination of passive and active methods) are commonly used in areas such as process industries, heating and cooling in evaporators, thermal power plants, air- conditioning equipment, refrigerators, radiators for space vehicles, automobiles, etc. Passive techniques, where inserts are used in the flow passage to augment the heat transfer rate, are advantageous compared with active techniques, because the insert manufacturing process is simple and these techniques can be easily employed in an existing heat exchanger. In design of compact heat exchangers, passive techniques of heat transfer augmentation can play an important role if a proper passive insert configuration can be selected according to the heat exchanger working condition (both flow and heat transfer conditions). In the past decade, several studies on the passive techniques of heat transfer augmentation have been reported. ...
2004-12-01
Energy Technology Data Exchange (ETDEWEB)
From 1977 through 1984, 293 previously untreated patients with biopsy proven carcinoma of the uterine cervix were treated by whole pelvis irradiation and high intensity 60Co remote afterloading (RAL) intrauterine tandem techniques in Haiti. The treatment results were analyzed retrospectively to evaluate the therapeutic results and prognostic factors of a strict protocol involving 40 Gy to the whole pelvis (2 Gy/day, 5 days/week). In addition, on the 5th day of the 3rd week, the first outpatient 60Co remote afterloading intracavitary insertion, delivering 7.5 Gy to point A with each insertion, repeated 3 times by a week separation for a total of 4 times. The total TDF for external beam plus RAL was 158 and 175 for early and late effects respectively. One hundred-four patients were evaluable after 1 year or more follow-up, with a median of 26.5 months. No evidence of disease (NED) by Stage at 1 year was: Stage I of 100% (3/3), Stage II of 82% (9/11), Stage III of 80% (47/59), and Stage ...
1988-06-01
FFTF operational results: startup to 100 MWd/kg
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a 400-MW(t) sodium-cooled fast reactor operating at the Hanford Engineering Development Laboratory in Richland, Washington, to conduct fuels and materials testing in support of the US liquid-metal fast breeder reactor program. Startup and initial power testing included a comprehensive series of nuclear and nonnuclear tests to verify the thermal and neutronic characteristics of the plant and to demonstrate its inherent safety features. Extensive reactor core characterization measurements were completed to provide the neutron and gamma spectra, fission rates, and other physics data needed to design and evaluate tests irradiated in the FFTF. A specially designed series of natural-circulation tests was performed to demonstrate the inherent safety features of the plant. Early in 1982 the FFTF began its first 100-d irradiation cycle. Since that time the plant has operated beyond expectations; it achieved a cycle capacity factor of 99.5% in the most ...
Energy Technology Data Exchange (ETDEWEB)
A considerable fraction of radioactivity entering the environment from different nuclear events is associated with particles. The impact of these events can only be fully assessed where there is some knowledge about the mobility of particle bound radionuclides entering the environment. The behavior of particulate radionuclides is dependent on several factors, including the physical, chemical and redox state of the environment, the characteristics of the particles (e.g., the chemical composition, crystallinity and particle size) and on the oxidative state of radionuclides contained in the particles. Six plutonium-containing particles stemming from Runit Island soil (Marshall Islands) were characterized using non-destructive analytical and microanalytical methods. By determining the activity of {sup 239,240}Pu and {sup 241}Am isotopes from their gamma peaks structural information related to Pu matrix was obtained, and the source term was revealed. Composition and elemental distribution ...
2005-06-11
Alternative Measuring Approaches in Gamma Scanning on Spent Nuclear Fuel
International Nuclear Information System (INIS)
In the future, the demand for energy is predicted to grow and more countries plan to utilize nuclear energy as their source of electric energy. This gives rise to many important issues connected to nuclear energy, such as finding methods that can verify that the spent nuclear fuel has been handled safely and used in ordinary power producing cycles as stated by the operators. Gamma ray spectroscopy is one method used for identification and verification of spent nuclear fuel. In the specific gamma ray spectroscopy method called gamma scanning the gamma radiation from the fission products Cs-137, Cs-134 and Eu-154 are measured in a spent fuel assembly. From the results, conclusions can be drawn about the fuels characteristics. This degree project examines the possibilities of using alternative measuring approaches when using the gamma scanning method. The focus is on examining how to increase the quality of the measured data. How to decrease the measuring time as ...
2009-03-01
Alternative Measuring Approaches in Gamma Scanning on Spent Nuclear Fuel
Energy Technology Data Exchange (ETDEWEB)
In the future, the demand for energy is predicted to grow and more countries plan to utilize nuclear energy as their source of electric energy. This gives rise to many important issues connected to nuclear energy, such as finding methods that can verify that the spent nuclear fuel has been handled safely and used in ordinary power producing cycles as stated by the operators. Gamma ray spectroscopy is one method used for identification and verification of spent nuclear fuel. In the specific gamma ray spectroscopy method called gamma scanning the gamma radiation from the fission products Cs-137, Cs-134 and Eu-154 are measured in a spent fuel assembly. From the results, conclusions can be drawn about the fuels characteristics. This degree project examines the possibilities of using alternative measuring approaches when using the gamma scanning method. The focus is on examining how to increase the quality of the measured data. How to decrease the measuring time as ...
2007-06-15
Energy Technology Data Exchange (ETDEWEB)
We report on a recent search for {bar {nu}}{sub e} appearance from stopped {pi}{sup +} {yields} {mu}{sup +}{nu}{sub {mu}} and {mu}{sup +} {yields} e{sup +}{nu}{sub e}{bar {nu}}{sub {mu}} decay made by the LAMPF experiment E645. The appearance of {bar {nu}}{sub e} may occur from {bar {nu}}{sub {mu}} {yields} {bar {nu}}{sub e}, {nu}{sub e} {yields} {bar {nu}}{sub eL}, or {nu}{sub {mu}} {yields} {bar {nu}}{sub eL} oscillations. Appearance may also occur from rare {mu}{sup +} {yields} e{sup +}{bar {nu}}{sub e}{nu}{sub {mu}} decay, which is allowed by a multiplicative lepton charge conservation law. The neutrino energies range from E{sub {nu}} = 0 to 52.8MeV. The neutrino detector, which is located 26.1 meters from the neutrino source, consists of a segmented liquid scintillator and proportional drift tube central detector surrounded by both active and passive shielding. The central detector detects {bar {nu}}{sub e} through the {bar {nu}}{sub e}p {yields} ne{sup +} ...
1990-01-01
Energy Technology Data Exchange (ETDEWEB)
This thesis presents the study of the slowing down process of fast heavy ions inside matter. In the framework of this research, the influence of the target density on the stopping process is investigated. Experiments on the interaction of {sup 48}Ca{sup 6+}-{sup 48}Ca{sup 10+} and {sup 26}Mg{sup 5+} ion beams with initial energies of 11.4 MeV/u and 5.9 MeV/u with solid and gaseous targets have been carried out. A novel diagnostic method, X-ray spectroscopy of K-shell projectile radiation, is used to determine the ion charge state in relation to its velocity during the penetration of fast heavy ions inside the stopping material. A spatially resolved analysis of the projectile and target radiation in solids is achieved for the first time. The application of low-density silica aerogels as stopping media provided a stretching of the ion stopping length by 20 - 100 times in comparison with solid quartz. The Doppler Effect observed on the projectile ...
2007-01-15
Energy Technology Data Exchange (ETDEWEB)
Many thermoluminescent materials has been developed and used for photon personal dosimetry but no one has all desired characteristics alone. These characteristics include robustness, high sensitivity, energy photon independence, large range of photon energy detection, good reproducibility, small fading and simple glow curve with peaks above 150 deg C. Calcium Sulfate Dysprosium doped (CaSO{sub 4}:Dy) phosphor Thermoluminescent Dosimeter (TLD) has been used by many laboratories, mainly in Brazil and India. Another interesting phosphor is Calcium Fluoride (CaF{sub 2}). These phosphor advantages begin to be more required and its disadvantages have became more apparent, in a global market more and more competitive. These phosphors are used in environmental and area monitoring, once they present more sensibility than other phosphors, like LiF:Mg. Theirs mainly disadvantage is a strong energetic dependence response, which must be corrected for theirs application in the ...
2006-07-01
Radial dose distribution of 6.0 MeV/n #alpha#-particle in water
International Nuclear Information System (INIS)
For the study of radiation biology and its application to radiotherapy, the double differential cross section of electron emission from water vapor induced by 6.0 MeV alpha particle beam is measured. The energy spectra of electrons ranging 7- 10000 eV are detected by the electrostatic analyzer and micro channel plate. The measurements are made at angles between 20 and 160 degrees. With use of this data set, the radial dose distribution in water is calculated by using KURBUC code. It is the Monte Carlo type code of the electron transport process, where the track of the electron is simulated through each individual interactions including elastic scattering, ionization cross section and total excitation cross section in case that electrons with certain energy are put in the liquid-density water. In order to understand the effect of radiation when the particle flux is injected in the human body like radiotherapy using ...
2003-08-17
Production of high-q ions by laser bombardment method
International Nuclear Information System (INIS)
The expanding plasma produced when an intense pulse of laser radiation is focused in vacuum onto a solid target has been used as a source of highly stripped ions for collision cross-section measurements. Usable fluxes of carbon nuclei at energies of a few hundred eV/charge have been obtained by irradiation of graphite with pulses of CO"2 laser radiation at a focused power density of 3 x 10_1_0 W/cm_2. Bombardment of aluminum and iron targets at comparable power levels have yielded ions of maximum charges of 9 and 16 respectively. A time-of-flight apparatus has been constructed to utilize the laser source for measurement of electron capture cross sections for highly stripped ions in gases at energies in the few hundred eV/charge range. Apertures collimate an ion beam from the plasma blowoff, and an electrostatic analyzer selects ions from the expanding plasma which have the same energy per charge. The beam is directed through a gas target cell, ...
1981-01-01
International Nuclear Information System (INIS)
This present study evaluated the effect of gamma radiation on the fungal survival in packed medicinal plants, purchased from wholesale and retail market, in different period (0 and 30 days) after the treatment. Five kind of medicinal plants (Peumus boldus, Camellia sinensis, Maytenus ilicifolia, Paullinia cupana and Cassia angustifolia), were collected from different cities of Sao Paulo State, and submitted to irradiation treatment using a 60Co source (type Gammacell 220) with doses of 5,0 kGy and 10 kGy and at dose rate of 3.0 kGy/h. Non-irradiated samples (control group) were used for fungal counts and serial dilutions from 10-1 to 10-6 of the samples were seeded in duplicates and plated using the surface culture method in Dichloran 18% Glycerol Agar (DG 18) and were counted after five days at 25 deg C. The control group revealed the presence of genera Aspergillus and Penicillium, which are known as toxigenic fungi and a few samples of control group were within ...
2006-12-20
A radiation hybrid map of the BRCA1 region of chromosome 17q12-q21
Energy Technology Data Exchange (ETDEWEB)
The chromosomal region 17q12-q21 contains a gene (BRCA1) conferring susceptibility to early-onset familial breast and ovarian cancer. An 8000-rad radiation-reduced hybrid (RH) panel was constructed to provide a resource for long-range mapping of this region. A large fraction of the hybrids ([approximately]90%) retained detectable human chromosome 17 sequences. The complete panel of 76 hybrids was scored for the presence or absence of 22 markers from this chromosomal region, including 14 cloned genes, seven microsatellite repeats, and one anonymous DNA segment. Statistical analysis of the marker retention data employing multipoint methods provided both comprehensive and framework maps of this chromosomal region, including distance estimates between adjacent markers. The comprehensive RH map includes 17 loci and spans 179 cRays[sub (8000)]. Likelihood ratios of at least 1000:1 support the 10-locus framework order: cen-D17S250-ERBB2-(THRA1, ...
1993-09-01
Donetskgormash association in the 11th five-year plan, tasks for the 12th five-year plan
Energy Technology Data Exchange (ETDEWEB)
This paper evaluates activities from 1981 to 1985 of the Donetskgormash association which develops and manufactures equipment for coal mining. The association has manufactured 1,410 hoists, 274 blowers and 26 bucket wheel excavators. Sixteen experimental units of new mining equipment have been developed, among others the RPM 3600-42.5/90 bucket wheel excavator (with a capacity of 3,600 m/sup 3//h for coal handling in storage yards of large power plants), the bucket wheel system used in the EhR 630-10.5/0.5 excavator and the PZ 1600-17/20 materials handling system. Among 20 equipment types manufactured from 1981 to 1985, 4 types were manufactured in the USSR for the first time (e.g. the MPP shaft sinking system and the VOD-50 mine blower). Use of new types of equipment manufactured by the association economized about 46 million rubles in coal mines. From 1986 to 1990 production of mining ...
1986-03-01
Current issues of nuclear equipment standardization in Romania
International Nuclear Information System (INIS)
Standardization enhances: international cooperation; development of new nuclear techniques and technologies; characterization and checking procedures of equipment; sharing a common terminology. A historical sketch is given focussing: inception of standardization in electro-techniques at international scale; organization of the International Electrotechnical Commission, IEC; - current aspects of nuclear equipment standardization; activity of seven working groups devoted to nuclear reactor equipment; activity of seven groups working on radioprotection equipment; activity of four groups working on nuclear equipment. ISO organization and present issues concerning the nuclear technology development in Romania. It is presented the activity in the frame of CENELEC, CLC/TC45, for endorsing the IEC/TC45B standards. In 2007 a CENELEC/ BTT 127-1 working commission was formed to enhance ...
2009-10-12
International Nuclear Information System (INIS)
... chemical radiation effects decomposition extraction columns gamma radiation
1972-01-01
International Nuclear Information System (INIS)
This text-book (electronic book - multi-media CD-ROM) constitutes a course-book - author's collection of lectures. It consists of 13 lectures in which the reader acquaints with the basis of radiobiology: Introduction to radiobiology; Physical fundamentals of radiobiology; Radiation of cells; Modification of radiation damage of cells; Reparation of radiation damage of cells; Radiation syndromes and their modification; Radiation injury; Radiation damage of tissues; Effect of radiation on embryo and fetus; Biological effects of incorporated radionuclides; Therapy of acute irradiation sickness; Delayed consequences of irradiation; Radiation oncology and radiotherapy. This course-book may be interesting for students, post-graduate students of chemistry, biology, physics, medicine as well as for teachers, scientific workers ...
Radiation Therapy in Treating Patients With Prostate Cancer
Prostate Cancer; Psychosocial Effects of Cancer and Its Treatment; Radiation Toxicity; Sexual Dysfunction and Infertility
2011-09-13
Measurement of fast fluctuations of radiation intensity in pulsed charged particle accelerators
International Nuclear Information System (INIS)
... beam monitoring betatrons delay circuits errors fluctuations gamma radiation
Standards and guidances for limiting ionizing radiation exposure
Energy Technology Data Exchange (ETDEWEB)
This chapter is concerned with standards and guidances for limiting radiation exposures. It is divided into three sections, each of which has several parts. Section 1: Ionizing Radiation -- Standards and Guidances Applicable to the Public: Part A, Radiation Protection Standards; Part B, Environmental Radiation Standards; Part C, Exempt Levels of Radioactivity; Part D, Protective Action Guides for Accidents. Section 2: Ionizing Radiation -- Standards Applicable to the Workplace. Section 3: Medical and Other Standards.
1992-12-31
Radiation protection in the operating room
International Nuclear Information System (INIS)
On the basis of legally provided area dose measurements and time records of fluoroscopic examinations during the operation, radiation doses to medical personnel and patients are evaluated. Adequate radiation protection measures and a careful behaviour in the operating room keep the radiation exposure to the personnel below the maximum permissible exposure. Taking into account the continuous personnel radiation monitoring and medical supervision, radiation hazards in the operating room can be considered low.
A review of 4 norm industries in Ireland
Energy Technology Data Exchange (ETDEWEB)
Full text: This presentation will review the progress achieved so far by the Irish national regulatory agency, the Radiological Protection Institut e of Ireland (R.P.I.I.) in the investigation of work activities where the presence of natural radiation sources (NORM) could lead to a significant increase in exposure to workers or members of the public which cannot be disregarded from the radiation protection point of view. Since the coming into force in Ma y 2000 of the Radiological Protection Act, 1991 (Ionising Radiation) Order, 2000 (S.I. No. 125 of 2000) which implements the Eu B.S.S. Directive 96/29/EURATOM, four major NORM industries currently active in Ireland have been investigated. According to the literature, they are all considered liable to involve work practices resulting in exposure to NORM. They include: the gas extraction and production industry, the peat- and coal-firing power generation industry and the ...
2006-07-01
Survey of Radiation Protection Education and Training in Finland in 2003
Energy Technology Data Exchange (ETDEWEB)
The current state and need for radiation protection training in Finland have been surveyed by the Radiation and Nuclear Safety Authority STUK. The survey sought to determine whether the current requirements for radiation protection training had been met, and to promote radiation protection training. Details of the scope and quality of present radiation protection training were requested from all educational institutes and organizations providing radiation protection training. The survey covered both basic and further training, special training of radiation safety officers, and supplementary training. The questionnaire was sent to 77 educational organization units, 66 per cent of which responded. Radiation workers and radiation safety officers were asked about radiation protection ...
2004-07-01
International Nuclear Information System (INIS)
Full text: The ITWG was first formed in 1995 for the purpose of fostering international cooperation for combating illicit trafficking of nuclear materials. The initial focus for the ITWG was on the development of nuclear forensics to help answer attribution questions regarding nuclear materials of unknown origin. More recently, the ITWG has also expanded its focus to include detection of nuclear materials during transit. This paper presents some of the key developments by this group and their potential impact for combating nuclear smuggling. The initial focus of the ITWG was to write a status report on international cooperation on nuclear smuggling forensic analysis. This 26-page report summarized previous work on nuclear forensics and gave an initial analysis on prioritizing techniques and methods for forensic analysis regarding source and route attribution. This report was submitted to the G-8 countries, and shortly thereafter, nuclear forensics was endorsed at ...
2002-10-21
The benefits of low level radiation
Energy Technology Data Exchange (ETDEWEB)
The assumed linear relationship between exposure to radiation and cancer incidence is questioned in this article. The current research data on radiation effects at the cellular level is reviewed, as are epidemiological studies of background radiation effects and health effects of populations exposed to low levels of radiation exposure via employment or medical treatments. Statistics reveal that threshold levels currently in force need to be reviewed. Some evidence of beneficial effects of low level radiation exposure effects of low level radiation exposure is also presented, and so regulations should be reviewed at an international level. (UK).
1997-06-01
Stimulated radiation of high - current relativistic electron beams
International Nuclear Information System (INIS)
The most propagated mechanisms of stimulated radiation of electron beam such as Cherenkov one-particle and collective effects, ondulator and magnetic bremsshrahlung radiations, Doppler anomalous effect, Thompson and Raman scattering and radiation are discussed. Relation of spontaneous radiation mechanisms of individual electron and stimulated radiation effects in electron beams has been elucidated, grounds of linear electrodynamics of radiative beam instabilities are stated, and main mechanisms of their nonlinear stabilization are elucidated as well. Various simulated processes in electron beams are considered from the unique point of view using a simple mathematical apparatus and such physical laws as conservation and Newton laws.
1987-01-01
UK PubMed Central (United Kingdom)
Behavioral detection of a low-frequency (40 Hz) vibratory dipole at source distances of 1.5–24 cm was measured by classically conditioned respiratory suppression in goldfish (Carassius...Full Text Available
2009-04-01
Early detection of bone metastases of Ewing's sarcoma by magnetic resonance imaging
International Nuclear Information System (INIS)
Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).
UK PubMed Central (United Kingdom)
Since current microbiology methods are not suitable to detect Clostridium perfringens in formalin-fixed, paraffin-embedded tissue samples, we developed a PCR assay to detect toxin-encoding...Full Text Available
2009-03-01
UK PubMed Central (United Kingdom)
Denaturing high-performance liquid chromatography (DHPLC) has been used extensively to detect genetic variation. We used this method to detect and identify Yersinia pestis KIM5 ciprofloxacin-resistant...Full Text Available
2003-07-01
Chemical process equipment for Hitachi. ; Featured equipment
Energy Technology Data Exchange (ETDEWEB)
The present article describes the specialities in various chemical process equipment fabricated by Hitachi. It introduces the thin-film evaporator which heats, vaporizes and concentrates high viscosity fluid and slurry under thin-film conditions, the centrifugal extractor which uses a high speed rotating rotor to separate two kinds of immiscible liquids effectively in counter current contact conditions under a gravitational force ranging from 2,000G to 4,500G, the process gas boiler and heat pipe equipment which recovers exhausted heat effectively from various plants, the furnace and quench systems which are applied to olefin plants, EDC cracking and steam reforming, and the equipment which has been supplied to chemical plants operated under severe conditions, such as high temperature, high pressure and corrosive atmosphere. It was demonstrated that these technologies and know-hows accumulated from Hitachi's ...
1993-01-01
Energy Technology Data Exchange (ETDEWEB)
This paper presents the description of methodological procedure specially developed for manufacturing mini turbines. This procedure is used in the design of a Francis type mini turbine with 12.5 kW. The housing volute and the suction tube of this equipment are manufactured with using composed material based on glass fiber and its distributor system is manufactured with stainless steel and brass. At the end it is presented an estimate cost of design / manufacturing of such equipment and a comparison with other equipment in the market.
2009-07-01
Long-term preventive maintenance of instrumentation control equipment for PWR plants
International Nuclear Information System (INIS)
Since the PWR plants in Japan have been operated more than 30 years, main instrumentation control equipment of analog systems has been renewed to digital control systems. Renewal works had to be done in short period within periodical inspection term and for several facilities. The Mitsubishi LTD group had been provided with these market needs by its digital control system (MELTAC-NplusR 3) applicable to main instrumentation control equipment for primary and secondary systems and had already finished the renewal for practical plants. (T. Tanaka)
2006-02-01
Co-operation Equipment Qualification for Safety grade I and C Equipment between Russia and Korea
Energy Technology Data Exchange (ETDEWEB)
Equipment Qualification technology for I and C system on nuclear grade have been approved with accurate and safe for verifying and validation. It contributes to acknowledge of reliability and to review of user approval. Also it did not completely satisfied the requirement of Russia, it can be satisfied by bit of modification on design. It is expected to support the export of safety PLC to nuclear power plant. Proven EQ technology is required on the further markets of nuclear. Therefore, comparison test with foreign country is necessary to support the mutual accreditation of EQ for export of domestic products.
2007-06-15
Integration of Microdialysis Sampling and Microchip Electrophoresis with Electrochemical Detection
UK PubMed Central (United Kingdom)
Here we describe the fabrication, optimization, and application of a microfluidic device that integrates microdialysis (MD) sampling, microchip electrophoresis (ME), and electrochemical detection...Full Text Available
2008-12-01
Direct Detection Optical Intersatelllte Link at 220 Mbps Using ...
on this technology has beenproposedas a payload on SpaceStation Freedom to be launched in the near future [1]. Direct detection 4-ary pulse position modula- ...
Development of a universal plate-agglutination test for detecting Haemophilus parasuis
UK PubMed Central (United Kingdom)
Due to the serovar diversity in Haemophilus (H.) parasuis, it is difficult to develop a universal serological method for detection of this pathogen....Full Text Available
2010-12-01
Detection of Microcalcification in Mammograms Using Wavelet Transform and Fuzzy Shell Clustering
Microcalcifications in mammogram have been mainly targeted as a reliable earliest sign of breast cancer and their early detection is vital to improve its prognosis. Since their size is very small and may be easily overlooked by the examining radiologist, computer-based detection output can assist the radiologist to improve the diagnostic accuracy. In this paper, we have proposed an algorithm for detecting microcalcification in mammogram. The proposed microcalcification detection algorithm involves mammogram quality enhancement using multirresolution analysis based on the dyadic wavelet transform and microcalcification detection by fuzzy shell clustering. It may be possible to detect nodular components such as microcalcification accurately by introducing shape information. The effectiveness of the proposed algorithm for microcalcification ...
2010-01-01
Detecting Airborne Mercury by Use of Palladium Chloride Detecting ...
Palladium chloride films have been found to be useful as ... when suitably prepared palladium chlo- ride films are exposed ... Like the palladium chloride ( PdCl2) ...
Color Fluorescence Ratio for Detection of Bronchial Dysplasia and Carcinoma In situ
UK PubMed Central (United Kingdom)
BackgroundAutofluorescence bronchoscopy is more sensitive than conventional bronchoscopy for detecting early airway mucosal lesions. Decreased specificity can lead...Full Text Available
2009-07-15
Radiation protection. A guide for scientists and physicians
International Nuclear Information System (INIS)
This manual was written for individuals who wish to become qualified in radiation protection as an adjunct to working with sources of ionizing radiation or using radionuclides in the field of medicine. It provides the radiation user with information needed to protect himself and others and to understand and comply with governmental and institutional regulations regarding the use of radionuclides and radiation machines. It is designed for a wide spectrum of users, including physicians, research scientists, engineers, and technicians. It should be useful also to radiation safety officers, members of radiation safety committees, and others who are responsible for the proper use of radiation sources, although they may not be working with the sources directly. The presentation in this manual is designed to obviate the need for reviews of atomic ...
British Library Electronic Table of Contents (United Kingdom)
Abstract Satellite measurements and numerical forecast model reanalysis data are used to compute an updated estimate of the cloud radiative effect on the global multi-annual mean radiative energy budget of the atmosphere and surface. The cloud radiative cooling effect through reflection of short wave radiation dominates over the long wave heating effect, resulting in a net cooling of the climate system of - 21 Wm-2. The short wave radiative effect of cloud is primarily manifest as a reduction in the solar radiation absorbed at the surface of - 53 Wm-2. Clouds impact long wave radiation by heating the moist tropical atmosphere (up to around 40 Wm-2 for global annual means) while enhancing the radiative cooling of the atmosphere over other regions, in particular higher latitudes and sub-trop...
2011-01-01
Biological effects of electromagnetic radiation in the microwave range
Energy Technology Data Exchange (ETDEWEB)
The book examines current experimental and clinical knowledge concerning the biological and biophysical effects of electromagnetic radiation, particularly that in the microwave range. The biophysical bases of the interaction of electromagnetic radiation with matter are reviewed with emphasis on biological systems, and the effects of radiation on critical biological systems, including the nervous, reproductive, visual and blood-forming systems are compared. Data concerning the lethal effects of nonionizing radiation is presented and characteristics of the effects of electromagnetic radiation on the whole mammalian organisms are examined. Various reactions of the neuroendocrine system to electromagnetic radiation are described, with particular attention given to the adrenal system, and the combined effects of ionizing and microwave radiation ...
1980-01-01
Underground reservoirs for high-head pumped-storage stations
The advantages of using heads of around 1000 m in conjunction with underground location of the lower reservoirs for pumped storage plants are described, and the possible layouts, equipment, and construction methods are discussed.
1973-03-01
New equipment recharges Oldham batteries
Energy Technology Data Exchange (ETDEWEB)
The battery manufacturing industry has not been immune to the impact of new technologies. How one company is adapting production techniques to meet the demand for better products is discussed.
1982-09-24
Innovative coke-oven door and cleaning equipment
Energy Technology Data Exchange (ETDEWEB)
Officials of Saturn Machine and Welding Co., describe the company's designs of oven door, door cleaner and jamb cleaner and report performance at US coking plants.
1989-09-01
Fast generation shedding equipment based on the observation of swings of generators
Energy Technology Data Exchange (ETDEWEB)
This paper presents a new method and newly developed stabilizing equipment to prevent the loss of synchronism of generators in pumped-storage plants from spreading. The proposed method includes functions to estimate the swing of each generator by using on-line generator output sampled at a rate of 600 times per second after an occurrence of disturbance such as fault, faulty equipment and so on, to predict generator swing 200-300 milliseconds ahead and loss of synchronism between generators in pumped-storage plants and those in thermal and nuclear plants, and to decide the number of generators that must be shed to maintain stability. Tokyo Electric Power Co. (TEPCO) installed the newly developed stabilizing equipment based on this method in the power system in June, 1986.
1988-05-01
Fast generation shedding equipment based on the observation of swings of generators
International Nuclear Information System (INIS)
This paper presents a new method and newly developed stabilizing equipment to prevent the loss of synchronism of generators in pumped-storage plants from spreading. The proposed method includes functions to estimate the swing of each generator by using on-line generator output sampled at a rate of 600 times per second after an occurrence of disturbance such as fault, faulty equipment and so on, to predict generator swing 200-300 milliseconds ahead and loss of synchronism between generators in pumped-storage plants and those in thermal and nuclear plants, and to decide the number of generators that must be shed to maintain stability. Tokyo Electric Power Co. (TEPCO) installed the newly developed stabilizing equipment based on this method in the power system in June, 1986.
1988-01-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent