Energy Technology Data Exchange (ETDEWEB)
The neutron detector is cased in a metal envelop and has one detector with a very sensitive fission chamber and a second detector with a fission chamber less sensitive that the first one and a boron coated ionisation chamber for reducing gamma radiation detection.
1992-06-12
Energy Technology Data Exchange (ETDEWEB)
A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the detector as rays parallel to the detector axis of the detector. The collimator may be a ...
2003-03-04
This investigation describes the technique for the detection of the X-ray fluorescent radiation
1972-01-01
Spontaneous radiation from relativistic electrons in a taper undulator. Technical report
The spectrum, angular distribution, polarization and coherence properties of the radiation emitted by relativistic electrons undulating through a quasiperiodic tapered magnetic field are studied. Tapering the wavelength and/or field strength along the undulator's axis has the effect of spreading the spectral line to higher frequencies; interference over this broader spectral range results in a more complex line shape. The angular dependence, on the other hand, is not affected by the amount of taper. The polarization of the radiation in the forward direction is determined by the transverse polarization of the undulator, but the polarization changes off axis. The radiation patterns predicted here are distinct from those of untapered undulators, and their detection is now feasible. They will provide useful diagnostics of electron trajectories and threshold behavior in ...
1983-06-01
Energy Technology Data Exchange (ETDEWEB)
Survival curves were constructed from dose-incidence curves for apoptosis in the crypts of mouse small intestine, using the number of apoptotic cells after high doses (N{sub M}) as maximum cell population size. The mean lethal doses (D{sub 0}) for the dose range 0-0.5 Gy were calculated for each time of day. A circadian rhythm in both D{sub 0} and N{sub M} values was detected, indicating that both the number and sensitivity of radiation-induced apoptosis were changing throughout the day. (author).
1990-07-01
British Library Electronic Table of Contents (United Kingdom)
Abstract A miniaturized spatial temperature gradient CE system with automated sample introduction for DNA mutation detection was established. Continuous electrokinetic sample injection was achieved by combining an automated slotted vial array sample introduction device to the spatial temperature gradient CE system. The temperature gradient was produced by a radiative heating system with a single graphite block heater, and the stability of the temperature gradient was investigated. The temperature variation of each measure point was 0.12 0.21% RSD (n=7) within 6 h. A 14 cm Teflon AF coated silica capillary was used both as the separation channel and as the liquid core waveguide tube of fluorescence signal. Under a temperature gradient from 54.8 to 59.5 C, a low range control mutation standa...
2010-01-01
Magnetospheric Emissions from the Planet Orbiting tau Boo: A Multi-Epoch Search
All of the solar system gas giants produce electron cyclotron masers, driven by the solar wind impinging on their magnetospheres. Extrapolating to the planet orbiting tau Boo, various authors have predicted that it may be within the detection limits of the 4-meter wavelength (74 MHz) system on the Very Large Array. This paper reports three epochs of observations of tau Boo. In no epoch do we detect the planet; various means of determining the upper limit to the emission yield single-epoch limits ranging from 135 to 300 mJy. We develop a likelihood method for multi-epoch observations and use it to constrain various radiation properties of the planet. Assuming that the planet does radiate at our observation wavelength, its typical luminosity must be less than about 10^{16} W, unless its radiation is highly beamed into a solid angle Omega << 1 sr. While ...
2007-01-01
Detection of irradiated chicken by ESR spectroscopy of bone
Energy Technology Data Exchange (ETDEWEB)
Ionizing radiation has been used to treat poultry to remove harmful microorganisms, mainly Salmonella, which contaminates chicken, goose and other fresh and frozen poultry. This microorganism is sensitive to low dose radiation. Thus, irradiating these foods with doses between 1 to 7 kGy results in a large reduction of bacteria. Since it is necessary to determine whether irradiation has occurred and to what extend, this work studied the signal produced by ionizing radiation within the hard crystalline matrix of chicken`s bone to establish a control method. Chicken`s drumsticks were irradiated and bones separated from flesh were lyophilized and milled. ESR spectrum was then obtained. The ESR signal increased linearly with dose over the range 0.25 to 8.0 kGy. Free radicals evaluated during 30 days after irradiation showed stable in this period. (Author).
1995-10-01
Measuring characteristics on emissivity using infrared thermometer for RCCS
International Nuclear Information System (INIS)
In VHTGR (Very High Temperature Gas-cooled Reactor), the radiation plays an important role in heat transfer through the cavity in RCCS (Reactor Cavity Cooling System). We performed the series of experiments to measure the emissivity using the infrared thermometer with wavelength range of 8#approx#14 #mu#m. As the first step, the transmittance of Zinc Selenide (ZnSe) window was measured to estimate the emissivity that can compensate the attenuation effect of window. The kind of gas with various concentrations in the cavity will be released during postulated accidents to the coolant type, so it is essential to estimate the effects of gas on the measurement of emissivity. In this manner we measured the emissivity with the air, the helium and the steam inside chamber. The results represent that the concentration of the air and the helium do not affect the emissivity significantly while the steam decreases the measured emissivity relatively. It ...
2004-12-01
Systematics of average radiative width of heavy nuclides
Energy Technology Data Exchange (ETDEWEB)
Systematics of neutron capture radiative width were studied in the target element range from Th to Cm. Reduced radiative widths were analyzed with a simple radiative width formula based on E1 transition. Average radiative width is presented with the standard deviation of 15%. (author)
1999-03-01
Supervision monitoring for radiation environment around Daya Bay and Lingao nuclear power stations
International Nuclear Information System (INIS)
This paper systematically introduces the supervision monitoring for radiation environment around the Guangdong Daya Bay and Ling Ao nuclear power station by the Guangdong Environmental Radiation Research and Monitoring Center. It includes the monitoring plan, methods, quality assurance, main results and conclusions. The results show that: (1) The gas discharge have not caused any detectable impacts to the terrestrial and atmospheric environment since their operation; (2) "1"1"0"mAg could only be detected in seawater in the West Daya Bay in 1995 and 1997 and in sediments in 1997. The maximum annual average in seawater was 3.1 Bq/m"3, annual average of "1"1"0"mAg in sediments was 1.0 Bq/kg(dry). But it was always detectable in pearl oyster, gulfweed and cuttlefish in the West Daya Bay. The "1"1"0"mAg concentrations in halobios were relatively higher in 1994, 1996 and 1997. The maximum ...
2004-05-01
Real-time neutron monitoring method using an imaging plate
Energy Technology Data Exchange (ETDEWEB)
A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)
1999-07-01
Real-time neutron monitoring method using an imaging plate
International Nuclear Information System (INIS)
A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)
1999-04-19
x - NASA Technical Reports Server
Mar 1, 2011 ... Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation ...
Multi-spectral schottky barrier infrared radiation detection array
Energy Technology Data Exchange (ETDEWEB)
A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.
1983-12-27
Multi-spectral schottky barrier infrared radiation detection array
International Nuclear Information System (INIS)
A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.
Modeling of Fission Neutrons as a Signature for Detection of Highly Enriched Uranium
Energy Technology Data Exchange (ETDEWEB)
We present the results of modeling intended to evaluate the feasibility of using neutrons from induced fission in highly enriched uranium (HEU) as a means of detecting clandestine HEU, even when it is embedded in absorbing surroundings, such as commercial cargo. We characterized radiation from induced fission in HEU, which consisted of delayed neutrons at all energies and prompt neutrons at energies above a threshold. We found that for the candidate detector and for the conditions we considered, a distinctive HEU signature should be detectable, given sufficient detector size, and should be robust over a range of cargo content. In the modeled scenario, an intense neutron source was used to induce fissions in a spherical shell of HEU. To absorb, scatter, and moderate the neutrons, we place one layer of simulated cargo between the source and target and an identical layer between the target and detector. ...
2004-03-09
Radiation-induced damage to DNA; Les lesions radio-induites de l'ADN
Energy Technology Data Exchange (ETDEWEB)
This short survey focuses on the main radiation-induced base lesions that have been identified within cellular DNA. For this purpose, sensitive assays that are aimed at measuring a few modifications per 10{sup 7} normal bases were set-up. In that respect high performance liquid chromatography - tandem mass spectrometry (CLHP-MS/MS) was found to be able to single out the formation of 9 oxidized nucleosides and two modified nucleo-bases out of the 70 oxidative base lesions that have been identified in model systems. As a striking result, it was found that in the DNA of {gamma}-irradiated human monocytes, the formamide-pyrimidine derivative of guanine is produced in a higher yield than the ubiquitous 8-oxo-7,8-dihydro-guanine damage, both arising from the same radical precursor. However, relatively high doses of ionizing radiation (> 20 Gy) have to be applied in order to detect an increase in the level of the damage. ...
2002-03-01
Development of a phoswich detector to detect neutrons in the charged-particle mixed field
Energy Technology Data Exchange (ETDEWEB)
Manned-space missions bring an exposure due to corpuscular radiations of which nature is quite different from what we encounter in the ground environment. In the space environment, many secondaries are produced through interactions of cosmic ray primaries with the spacecraft wall and other surrounding materials. Among this large variety of radiation components in the space, the contribution of neutrons to the radiation exposure of astronauts has remained to be studied. Up to today, efforts to measure neutron dose equivalent have been made using passive detector systems. Considering uncertainties involved in current measurements and estimations of high energy neutrons, and their increasing importance for future manned missions, it is necessary to measure neutron spectrum in the spacecraft under realistic conditions. The neutron spectra have never been measured on board a spacecraft, because the neutron measurement requires ...
1997-07-01
Chinese Journal of Lasers (Selected Articles)
... spontaneous radiation of amplifiers within a relatively w~de range of ... pulse widths are 20-30ns, while amplified spontaneous radiation pulse ...
1991-12-10
Infrared radiation features of coal and rocks under loading
Energy Technology Data Exchange (ETDEWEB)
Samples of fat coal-E, its roof sandstone-A and blind coal-W from two coal mines in Hebei Province of China were brought to the laboratory to study the features of infrared thermal images and radiation temperature in the course of uni-axial load and uni-axial cycle load. To check the results of infrared remote sensing detection, two other methods, acoustic emission detection and electrical resistance detection were also used. The AGA-782 thermalvision detected change of the temperature field of the samples` surfaces. The study showed that: (1) coal rocks and sandstone in the course of loading have three types of infrared thermal image features and three types of infrared radiation temperature features; (2) infrared detection is comparable with acoustic emission detection and electrical resistance ...
1998-10-01
Energy Technology Data Exchange (ETDEWEB)
In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the {sup 137}Cs-source with 10.4 GBq and {sup 60}Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form {sup 137} Cs 1173.23 and 1332.51 keV{sup 60} Co sources, and 14 peaks of {sup 134}Cs and {sup 154}Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that the ...
2003-10-01
International Nuclear Information System (INIS)
In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the "1"3"7Cs-source with 10.4 GBq and "6"0Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form "1"3"7 Cs 1173.23 and 1332.51 keV"6"0 Co sources, and 14 peaks of "1"3"4Cs and "1"5"4Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that the detection ...
2003-10-01
Chemical, sensory and microbiological changes of gamma irradiated coconut cream powder
Energy Technology Data Exchange (ETDEWEB)
A study was carried out to determine optimum decontamination dose for a locally manufactured coconut cream powder. Samples were gamma irradiated (0-15 kGy) and ageing process was achieved using GEER oven at 60 deg. C for 7 days, which is equivalent to one-year storage at room temperature. Iodine value (IV), ranging from 4.8 to 6.4, was not affected by radiation doses and storage, however peroxide value and thiobarbituric acid (TBA) generally increased with radiation doses. In most samples, peroxide value (meq/kg) reduced after storage, whilst the TBA (mg malonaldehyde/kg), indicator for product quality, slightly increased. The sensory evaluation conducted using 25 taste panellists indicated that scores on odour, creamy taste and overall acceptance for all irradiated samples at more than 5 kGy were significantly lower (P<0.05) than the control. However, the panellists could not detect any ...
2007-11-15
Status of the WAND (Waste Assay for Nonradioactive Disposal) project as of July 1997
Energy Technology Data Exchange (ETDEWEB)
The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform the data analysis. WAND system minimum detectable activities (MDAs) for point sources ...
1998-03-01
The influence of scattered radiation on recording systems and quality-assurance test parameters
International Nuclear Information System (INIS)
Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).
1988-02-23
The influence of scattered radiation on recording systems and quality-assurance test parameters
International Nuclear Information System (INIS)
Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).
British Library Electronic Table of Contents (United Kingdom)
Even if there have been efforts to validate remote-sensing-based energy balance models, which provide evapotranspiration (ET) maps over a large spatial scale, few studies have been conducted to validate their performance in Korea. In this study, surface energy balance fluxes including ET were estimated and inter-compared with two different models using the Landsat-5 Thematic Mapper (TM) image over a watershed scale in Korea. While there were larger spatial discrepancies for net radiation, soil heat and sensible heat fluxes on a pixel-by-pixel basis between the two models, relatively smaller spatial discrepancies for the latent heat flux and daily ET were detected. The spatial discrepancies for the daily ET were larger in low topography and dense vegetation ranges. Despite the different par...
2011-01-01
Two- and three-phonon states in "8"8Sr
International Nuclear Information System (INIS)
... de-excitation excited states gamma radiation inelastic scattering mev range
The structure of the 4.743 MeV state in "8"8Sr
International Nuclear Information System (INIS)
... states gamma radiation mev range 01-10 photonuclear reactions polarization
Lifetime of 2.734 mev Sr"8"8 level
International Nuclear Information System (INIS)
... range 01-10 nuclei photons radiation sources recoils resonance scattering
A scissors-like excitation on top of the quadrupole vibrational state in "8"8Sr
International Nuclear Information System (INIS)
... excitation experimental data gamma radiation mev range 01-10 parity
Biological effects of electromagnetic radiation in the microwave range
Energy Technology Data Exchange (ETDEWEB)
The book examines current experimental and clinical knowledge concerning the biological and biophysical effects of electromagnetic radiation, particularly that in the microwave range. The biophysical bases of the interaction of electromagnetic radiation with matter are reviewed with emphasis on biological systems, and the effects of radiation on critical biological systems, including the nervous, reproductive, visual and blood-forming systems are compared. Data concerning the lethal effects of nonionizing radiation is presented and characteristics of the effects of electromagnetic radiation on the whole mammalian organisms are examined. Various reactions of the neuroendocrine system to electromagnetic radiation are described, with particular attention given to the adrenal system, and the combined effects of ionizing and microwave ...
1980-01-01
DOE personnel neutron dosimetry evaluation and upgrade program
Energy Technology Data Exchange (ETDEWEB)
The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. ...
1988-10-01
International Nuclear Information System (INIS)
... 3-89701-147-6 0949-2224 245 p. animal cells dna genetic radiation effects
1998-03-01
Energy Technology Data Exchange (ETDEWEB)
The optically stimulated luminescence (OSL) results a highly appropriate dosimetric technique for readings of absorbed radiation 'in alive' and 'in situ', as well as in real time. The CVD diamond on the other hand presents excellent qualities like radiation reader thanks to its reproducibility, radiation resistance, biocompatibility and non toxicity. The present work studies the answer of two diamond films pure and polluted with nitrogen (750 ppm) grown by the Chemical Vapor Deposition method (CVD) on silicon substrate (001) irradiated with beta (Sr-90) in the 0.833-100 Gy interval. The optical stimulation was carried out by 40 seconds with infrared laser (830 nm, 0.36 W/cm{sup 2}) and the filter BG-39 (300-600 nm) coupled the PM. The intensity and the decay of the hyperbolic type of the LOE curves were similar in both samples, for the non doped diamond were observed trapping states in ...
2006-07-01
Energy Technology Data Exchange (ETDEWEB)
Disclosed herein is a radiation detector providing for the in situ automatic sampling of fluids containing substances emitting radiation, especially Cerenkov radiation. The detector permits sampling within well casings and is self-purging such that no additional provisions must be established for the storage and disposal of contaminated fluids.
1993-01-01
Induction and use of sex linked lethal mutations in the pink bollworm
International Nuclear Information System (INIS)
The sterile insect release technique can often be improved by removal of females before release. Rearing efficiencies can also be increased if removal of the females occurs at early developmental stages. In order to begin to develop genetic sexing strains for the pink bollworm, Pectinophora gossypiella (Saunders), it was necessary to determine the best dosage of radiation for induction of viable sex linked recessive lethal mutations and to see if stocks containing induced sex linked lethals could be maintained in culture. Sex linked recessive lethal mutations can be detected by distorted sex ratios in the progeny of treated adults. However, in the pink bollworm, highly distorted sex ratios are common even in the absence of induced mutations. Therefore, a visible sex linked trait, purple eye, was used as a marker for the untreated X-chromosomes in crosses. Thus, the presence of a recessive sex linked lethal mutation induced by the ...
1987-11-16
A clinical perspective on common forms of acquired heterotopic ossification
Energy Technology Data Exchange (ETDEWEB)
The clinical courses of heterotopic ossification (HO) as a consequence of trauma and central nervous system insults have many similarities as well as dissimilarities. Detection is commonly noted at two months. The incidence of clinically significant HO is 10%-20%. Approximately 10% of the HO is massive and causes severe restriction in joint motion or ankylosis. The most common sign and symptom are decreased range of motion and pain. The locations are the proximal limbs and joints. Sites of HO about a joint may vary according to the etiology of the HO. Roentgenographic evolution of HO occurs during a six-month period in the majority of patients. Treatment modalities include diphosphonates, indomethacin, radiation, range of motion exercises, and surgical excision. Surgical timing differs according to etiology: traumatic HO may be resected at six months; spinal cord injury HO is excised at one year; and ...
1991-02-01
A clinical perspective on common forms of acquired heterotopic ossification
International Nuclear Information System (INIS)
The clinical courses of heterotopic ossification (HO) as a consequence of trauma and central nervous system insults have many similarities as well as dissimilarities. Detection is commonly noted at two months. The incidence of clinically significant HO is 10%-20%. Approximately 10% of the HO is massive and causes severe restriction in joint motion or ankylosis. The most common sign and symptom are decreased range of motion and pain. The locations are the proximal limbs and joints. Sites of HO about a joint may vary according to the etiology of the HO. Roentgenographic evolution of HO occurs during a six-month period in the majority of patients. Treatment modalities include diphosphonates, indomethacin, radiation, range of motion exercises, and surgical excision. Surgical timing differs according to etiology: traumatic HO may be resected at six months; spinal cord injury HO is excised at one year; and ...
Energy Technology Data Exchange (ETDEWEB)
It may be necessary to reduce microbiological contamination of crude drugs (medicinal plants or their parts like roots, leaves, flowers). This can be done by treating the drugs with ionizing radiation. Meethods for detection of such an irradiation were developed. It could be pointed out that measurements of luminescence, viscosity and electron spin resonance were suitable for specific drugs, but not for all drugs. (orig.).
1992-09-01
Detection of Free-Living Amoebae in Some Water Sources and its Control by Ultraviolet- Radiation
International Nuclear Information System (INIS)
Among the numerous free-living amoebae (FLA) of soil and water habitats, certain species belonging to two genera Acanthamoeba and Naegleria are facultative parasites of man.They cause disease called primary amoebic meningoencephalitis where history of contact with water was recorded in most of the cases especially with Naegleria species. The present work aimed to search for presence of free-living amoebae in the water and trials for its control by Ultraviolet-radiation (UV-radiation). Samples from different water sources were examined for the presence of free-living amoebae. These samples were cultured on non-nutrient agar streaked with bacteria. Amoebae were detected and identified by means of their morphological characters. Twelve positive cases of one hundred and twenty examined samples could be detected. The positive samples were exposed to different doses of UV-radiation for ...
Method and device for identifying different species of honeybees
Energy Technology Data Exchange (ETDEWEB)
A method and device have been provided for distinguishing Africanized honeybees from European honeybees. The method is based on the discovery of a distinct difference in the acoustical signatures of these two species of honeybees in flight. The European honeybee signature has a fundamental power peak in the 210 to 240 Hz range while the Africanized honeybee signature has a fundamental power peak in the 260 to 290 Hz range. The acoustic signal produced by honeybees is analyzed by means of a detecting device to quickly determine the honeybee species through the detection of the presence of frequencies in one of these distinct ranges. The device includes a microphone for acoustical signal detection which feeds the detected signal into a frequency analyzer which is designed to detect the presence of either of the known ...
1989-01-01
International Nuclear Information System (INIS)
The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous ...
2008-05-01
Indirect Dark Matter Detection with Cosmic Antimatter
The indirect detection of particle dark matter (DM) is based on the search for anomalous components in cosmic rays (CRs) due to the annihilation of DM pairs in the galactic halo, on the top of the standard astrophysical production. These additional exotic components are potentially detectable at Earth as spectral distortions for the various cosmic radiations: $\\chi + \\chi \\to q \\bar{q}, W^+ W^-, ... \\to \\bar{p}, \\bar{D}, e^+ \\gamma and \
2010-01-01
Skin as an endocrine organ: implications for its function
UK PubMed Central (United Kingdom)
Described as the body's largest organ, the skin is strategically located at the interface with the external environment where it has evolved to detect, integrate and respond to a diverse range...Full Text Available
2008-06-01
Flashlamp radiation recycling for enhanced pumping efficiency and reduced thermal load
Energy Technology Data Exchange (ETDEWEB)
A method for recycling laser flashlamp radiation in selected wavelength ranges to decrease thermal loading of the solid state laser matrix while substantially maintaining the pumping efficiency of the flashlamp.
1989-01-01
Investigation of radiation effects of interaction of #beta#"- -radiation with polyvinylchloride
International Nuclear Information System (INIS)
Dissipation of energy of #beta#"--radiation in polyvinylchloride (PVC) was analyzed. Change of PVC properties at irradiation by beta beams with energy 2,32 MeV was characterized using potentials of inter- and intramolecular interactions as well as Born potential. Correlation between some micro- and macroproperties of PVC was detected and ways of their controlled correction were proposed. (authors)
Estimation of X-rays dose in the crystals of final thickness
International Nuclear Information System (INIS)
A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.
Energy Technology Data Exchange (ETDEWEB)
The US DOE manages the safe storage of approximately 650,000 tons of depleted uranium hexafluoride remaining from the Cold War. This slightly radioactive, but chemically active, material is contained in more than 46,000 steel storage cylinders that are located at Oak Ridge, Tennessee; Paducah, Kentucky; and Portsmouth, Ohio. Some of the cylinders are more than 40 years old, and approximately 17,500 are considered problem cylinders because their physical integrity is questionable. These cylinders require an annual visual inspection. The remainder of the 46,000-plus cylinders must be visually inspected every four years. Currently, the cylinder inspection program is extremely labor intensive. Because these inspections are accomplished visually, they may not be effective in the early detection of leaking cylinders. The inspection program requires approximately 12--14 full-time-equivalent (FTE) employees. At the cost of approximately $125K per FTE, this translates to ...
1997-02-01
International Nuclear Information System (INIS)
We describe a new apparatus that combines pulsed laser excitation in a molecular beam with surface-science methods for preparation of clean single-crystal surfaces and detection of adsorbates to enable state-selected studies of gas-surface reaction dynamics. Reactant molecules are prepared in specific vibrationally excited states via overtone pumping using tunable, narrow-band laser radiation. The collision-free environment of the molecular beam prevents relaxation of the prepared molecules before impact on the target surface and enables complete control over the collision energy and incidence angle. Chemisorption products are detected after a given deposition time by Auger electron spectroscopy. To achieve sufficient beam flux of state-selected reactant molecules for product detection by standard surface-science techniques, we use a high-intensity, short-pulse molecular-beam source matched to the low ...
2003-09-01
On penetration effect in M1 component of 70.45 keV #gamma#-transition in "1"7"7Ta
International Nuclear Information System (INIS)
... gamma radiation l conversion m conversion mev range 10-100 mixing ratio
1987-04-14
Radiation Isotope Identification Device (RIIDs) Field Test and Evaluation Campaign
Energy Technology Data Exchange (ETDEWEB)
Handheld, backpack, and mobile sensors are elements of the Global Nuclear Detection System for the interdiction and control of illicit radiological and nuclear materials. They are used by the U.S. Department of Homeland Security (DHS) and other government agencies and organizations in various roles for border protection, law enforcement, and nonproliferation monitoring. In order to systematically document the operational performance of the common commercial off-the-shelf portable radiation detection systems, the DHS Domestic Nuclear Detection Office conducted a test and evaluation campaign conducted at the Nevada Test Site from January 18 to February 27, 2006. Named 'Anole', it was the first test of its kind in terms of technical design and test complexities. The Anole test results offer users information for selecting appropriate mission-specific portable ...
2007-08-01
International Nuclear Information System (INIS)
To respond to an increase of social problems concerning orphan sources in Japan, a working group was formed in the Japan Health Physics Society. In this working group, we investigated how to prevent acute radiation hazard or social panic regarding orphan sources in scrap metal and detection system for orphan sources brought into scrap yards before recycle. For detection system in a scrap yard we conducted an experiment on detectability of monitoring instrument using a radiation source mixed in scrap metal on a truck. The result showed that it was not easy to detect even a high-level source if it was shielded by scrap metal. We also estimated detection limits for radioactive materials in scrap metal by calculation that was validated with experimental data. We summarized present status about orphan sources in Japan and proposed a ...
2002-10-20
Radial dose distribution of 6.0 MeV/n #alpha#-particle in water
International Nuclear Information System (INIS)
For the study of radiation biology and its application to radiotherapy, the double differential cross section of electron emission from water vapor induced by 6.0 MeV alpha particle beam is measured. The energy spectra of electrons ranging 7- 10000 eV are detected by the electrostatic analyzer and micro channel plate. The measurements are made at angles between 20 and 160 degrees. With use of this data set, the radial dose distribution in water is calculated by using KURBUC code. It is the Monte Carlo type code of the electron transport process, where the track of the electron is simulated through each individual interactions including elastic scattering, ionization cross section and total excitation cross section in case that electrons with certain energy are put in the liquid-density water. In order to understand the effect of radiation when the particle flux is injected in the human body like ...
2003-08-17
Production of high-q ions by laser bombardment method
International Nuclear Information System (INIS)
The expanding plasma produced when an intense pulse of laser radiation is focused in vacuum onto a solid target has been used as a source of highly stripped ions for collision cross-section measurements. Usable fluxes of carbon nuclei at energies of a few hundred eV/charge have been obtained by irradiation of graphite with pulses of CO"2 laser radiation at a focused power density of 3 x 10_1_0 W/cm_2. Bombardment of aluminum and iron targets at comparable power levels have yielded ions of maximum charges of 9 and 16 respectively. A time-of-flight apparatus has been constructed to utilize the laser source for measurement of electron capture cross sections for highly stripped ions in gases at energies in the few hundred eV/charge range. Apertures collimate an ion beam from the plasma blowoff, and an electrostatic analyzer selects ions from the expanding plasma which have the same energy per charge. The beam is directed ...
1981-01-01
XPS/AES Study of Electrical and Chemical Properties of Pd/SiC Interface
Silicon carbide (SiC) based electronic devices are of great importance for applications under the condition of high temperature, high power and high radiation. Schottky diodes of Palladium/SiC are good candidates for hydrogen and hydrocarbon gas sensors at elevated temperature. The detection sensibility of the diodes has been found heavily temperature dependent. In this work, the electrical and chemical properties of Pd/SiC Schottky contacts were studied by XPS and AES at different annealing temperatures. Schottky diodes were made by depositing ultra-thin palladium films onto a silicon carbide substrate. No significant change in the Schottky barrier height of the Pd/SiC contact was found in the temperature range of 300-673K. Palladium diffusion into SiC and the formation of palladium silicides were observed at room temperature and became significant at 300^oC and higher temperature. The mechanism of diffusion and reaction ...
1997-11-01
X-Ray Fluorescence in Research on the Cultural Heritage
Energy Technology Data Exchange (ETDEWEB)
Radionuclide X-ray fluorescence analysis is a method, which has many advantages for analysing various historic artefacts, as it is relatively cheap, sensitive and non-destructive, and it allows measurements in-situ. However, this analysis has also certain limitations especially concerning sensitivity to chemical elements only, irrespective of the compounds or chemical forms in which these elements have been bonded. In addition, light elements emitting very soft X-rays cannot be measured, and in order to detect a wide range of elements, it is necessary to carry out repeated measurements with different radiation sources. Despite these limitations, valuable information can be obtained about the composition of historic materials and data about the origin and age of these artefacts can be derived. Analyses of wall paintings, ancient metal sculptures or other objects of art provide the basis for historic considerations documented ...
2001-09-15
X-Ray Fluorescence in Research on the Cultural Heritage
International Nuclear Information System (INIS)
Radionuclide X-ray fluorescence analysis is a method, which has many advantages for analysing various historic artefacts, as it is relatively cheap, sensitive and non-destructive, and it allows measurements in-situ. However, this analysis has also certain limitations especially concerning sensitivity to chemical elements only, irrespective of the compounds or chemical forms in which these elements have been bonded. In addition, light elements emitting very soft X-rays cannot be measured, and in order to detect a wide range of elements, it is necessary to carry out repeated measurements with different radiation sources. Despite these limitations, valuable information can be obtained about the composition of historic materials and data about the origin and age of these artefacts can be derived. Analyses of wall paintings, ancient metal sculptures or other objects of art provide the basis for historic considerations documented ...
2001-09-01
Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the art
Energy Technology Data Exchange (ETDEWEB)
The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal equilibrium, homogeneous plasma, thin ...
2010-01-15
Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the art
International Nuclear Information System (INIS)
The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal equilibrium, homogeneous plasma, thin ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
Diffuse {gamma}-ray emission produced by the interaction of cosmic-ray particles with matter and radiation in the Galaxy can be used to probe the distribution of cosmic rays and their sources in different regions of the Galaxy. With its large field of view and long observation time, the Milagro Gamma Ray Observatory is an ideal instrument for surveying large regions of the Northern Hemisphere sky and for detecting diffuse {gamma}-ray emission at very high energies. Here, the spatial distribution and the flux of the diffuse {gamma}-ray emission in the TeV energy range with a median energy of 15 TeV for Galactic longitudes between 30{sup o} and 110{sup o} and between 136{sup o} and 216{sup o} and for Galactic latitudes between -10{sup o} and 10{sup o} are determined. The measured fluxes are consistent with predictions of the GALPROP model everywhere except for the Cygnus region (l {element_of} [65{sup o}, 85{sup o}]). For the ...
2008-05-14
Gravitational waves from the big bang
Energy Technology Data Exchange (ETDEWEB)
The gravitational radiation produced by the big bang is calculated in order to provide a condition for the unification of the gravitational and electromagnetic forces. By analogy with electromagnetic radiation and under the assumption that gravity is also quantized, it is shown that matter would have decoupled from gravitational radiation at a time of approximately 10 to the -43rd sec and would have dominated it at 10 to the -17th sec. Furthermore, the theory predicts a background gravitational radiation temperature of 0.003 K which peaks at a wavelength of about 1 m, which may be detected by the comparison of the synchronization of clocks at increasing distances.
1980-12-20
Energy Technology Data Exchange (ETDEWEB)
In embodiments, spectroscopic monitor monitors modulated light signals to detect low levels of contaminants and other compounds in the presence of background interference. The monitor uses a spectrometer that includes a transmissive modulator capable of causing different frequency ranges to move onto and off of the detector. The different ranges can include those with the desired signal and those selected to subtract background contributions from those with the desired signal. Embodiments of the system are particularly useful for monitoring metal concentrations in combustion effluent.
2003-01-01
Optic probe for semiconductor characterization
Energy Technology Data Exchange (ETDEWEB)
Described herein is an optical probe (120) for use in characterizing surface defects in wafers, such as semiconductor wafers. The optical probe (120) detects laser light reflected from the surface (124) of the wafer (106) within various ranges of angles. Characteristics of defects in the surface (124) of the wafer (106) are determined based on the amount of reflected laser light detected in each of the ranges of angles. Additionally, a wafer characterization system (100) is described that includes the described optical probe (120).
2008-09-02
Identification of oxidation states of ultra-trace elements by radiation detection
International Nuclear Information System (INIS)
The determination of the oxidation state of ultra-trace elements in the environment, especially in the case of actinides, is of importance in many ways. Speciation techniques using radiation may comprise methods based on the detection of the nuclear and atomic radiations emitted in radioactive decay or methods using external sources of excitation. In the former instance, information can be obtained from the energy and intensity of radiation, but at present the partition method is still the most commonly used, although its reliability is questionable. Excitation with intense laser beams, as is currently being used for trace element analysis in photoacoustic and thermal lensing spectroscopic techniques, could conceivably be applied under suitable conditions to ultra-trace elements with a sensitivity approaching that of the radiochemical methods.
1989-11-01
Energy Technology Data Exchange (ETDEWEB)
A solar unit is described which contains a cavity radiation receiver, parabolic-cylindrical concentrator, and reflector arranged between the radiation receiver and the concentrator symmetrically in relation to the optical plane of the latter. In order to expand the range of use, it contains a pair of flat mirrors with 2 working surfaces installed at an angle and symmetrically to the optical plane of the parabolic cylindrical concentrator between them and the reflector, while the latter is made in the form of 2 flat mirrors installed at an angle on the cavity radiation receiver.
1982-01-01
Nuclear Raman processes and the development of gamma-ray lasers
International Nuclear Information System (INIS)
This review briefly describes current efforts to develop superradiant sources of coherent radiation for the sub-nanometer range of wavelenghs, using nuclear rather than the atomic or molecular transitions that are stimulated in existing lasers. First the radiative (including Raman) interactions of nuclei with those of atoms and molecules are compared; then the present status of research on the fundamental problems involved in stimulating nuclear gamma radiation is described. (author). 20 refs.; 2 figs.
ETB dosemeter, a passive integrating radon dosemeter combining activated charcoal and TLD
Energy Technology Data Exchange (ETDEWEB)
A passive integrating radon dosemeter is described. The radon dosemeter is based on radon adsorption on activated charcoal. By placing TLD crystals inside an open charcoal container, the beta radiation from radon daughters, produced by the decay of adsorbed radon, is detected continuously during the exposure time. After closing the container, radiation will still be detected by the TLD crystal. Calibration procedures are reported and the suitability of the dosemeter is discussed. The dosemeter proved to be suitable for measurements during periods from a few days to two weeks both in domestic and mine atmospheres.
1983-01-01
Development of calibration facility for radiation protection monitoring instruments
International Nuclear Information System (INIS)
Exposure control at the operating Nuclear Power Station is a major concern. The challenging task of meeting the International standards in the field of radiation protection is the calibration of the radiation monitoring instruments and interpretation of personnel and area monitoring results. Correct interpretation is based on accurate calibration of radiation measuring instruments. The reliability and accuracy of the measurements are also partly based on the procedures applied in calibration. Inadequate calibration can cause large errors in dose estimation in complete dose rate range and energy range. Semiautomatic calibration facility established at TAPS 3 and 4 for radiation monitoring instruments. Objective of calibration facility is (a) Ensure instruments are working properly (b) calibration adjustment and (c) in case without calibration adjustment to reveal ...
2008-11-19
Energy Technology Data Exchange (ETDEWEB)
Many thermoluminescent materials has been developed and used for photon personal dosimetry but no one has all desired characteristics alone. These characteristics include robustness, high sensitivity, energy photon independence, large range of photon energy detection, good reproducibility, small fading and simple glow curve with peaks above 150 deg C. Calcium Sulfate Dysprosium doped (CaSO{sub 4}:Dy) phosphor Thermoluminescent Dosimeter (TLD) has been used by many laboratories, mainly in Brazil and India. Another interesting phosphor is Calcium Fluoride (CaF{sub 2}). These phosphor advantages begin to be more required and its disadvantages have became more apparent, in a global market more and more competitive. These phosphors are used in environmental and area monitoring, once they present more sensibility than other phosphors, like LiF:Mg. Theirs mainly disadvantage is a strong energetic dependence response, which must be corrected for theirs ...
2006-07-01
A radiation hybrid map of the BRCA1 region of chromosome 17q12-q21
Energy Technology Data Exchange (ETDEWEB)
The chromosomal region 17q12-q21 contains a gene (BRCA1) conferring susceptibility to early-onset familial breast and ovarian cancer. An 8000-rad radiation-reduced hybrid (RH) panel was constructed to provide a resource for long-range mapping of this region. A large fraction of the hybrids ([approximately]90%) retained detectable human chromosome 17 sequences. The complete panel of 76 hybrids was scored for the presence or absence of 22 markers from this chromosomal region, including 14 cloned genes, seven microsatellite repeats, and one anonymous DNA segment. Statistical analysis of the marker retention data employing multipoint methods provided both comprehensive and framework maps of this chromosomal region, including distance estimates between adjacent markers. The comprehensive RH map includes 17 loci and spans 179 cRays[sub (8000)]. Likelihood ratios of at least 1000:1 support the 10-locus framework order: ...
1993-09-01
Scattered radiation effect on the defect image in high-energy bremsstrahlung introscopy
International Nuclear Information System (INIS)
Results of the evaluation of the scattered radiation effect on the image of defects in examined products are given. The formula is suggested which characterizes the image of defects on a scintillation screen as well as accumulation factors are calculated by the Monte-Carlo method. Values of fluctuations of absorbed energy in the screen used for the evaluation of sensitivity are experimentally obtained. The effect of high-energy bremsstrahlung on the defect detection is analyzed.
Energy Technology Data Exchange (ETDEWEB)
Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A /sup 241/Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer.
1984-10-01
International Nuclear Information System (INIS)
Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A "2"4"1Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer. (E.S.).
1984-01-01
International Nuclear Information System (INIS)
The book presents a very good account of all aspects of protection from ionizing radiation. The quantities and units are given and defined used in nuclear physics and dosimetry. The effects of ionizing radiation on cells and on man are described. The principles are presented of radiation protection including limits and valid regulations and decrees. Also discussed is internal irradiation and its modelling. A great part of the book is devoted to aspects of monitoring persons, the living and working environment and to the determination of internal contamination. The system of radiation protection in Czechoslovakia is described and some practical questions are discussed of protection during radiodiagnosis and radiotherapy, in the nuclear fuel cycle, in the operation of nuclear power installations and in crack detection. In conclusion a survey is given of the population exposure from ...
1988-01-01
British Library Electronic Table of Contents (United Kingdom)
Abstract Ionizing radiation is a ubiquitous feature of the Cosmos, from exogenous cosmic rays (CR) to the intrinsic mineral radioactivity of a habitable world, and its influences on the emergence and persistence of life are wide-ranging and profound. Much attention has already been focused on the deleterious effects of ionizing radiation on organisms and the complex molecules of life, but ionizing radiation also performs many crucial functions in the generation of habitable planetary environments and the origins of life. This review surveys the role of CR and mineral radioactivity in star formation, generation of biogenic elements, and the synthesis of organic molecules and driving of prebiotic chemistry. Another major theme is the multiple layers of shielding of planetary surfaces from th...
2011-01-01
Free electron radiation and the Beijing Free Electron Laser
International Nuclear Information System (INIS)
Various particle-photon or beam-wave interactions are discussed. To be of use as intense radiation sources, it is necessary that these interactions produce coherent radiation. The free electron laser (FEL), developed on the basis of undulator radiation, is the result of many years of interaction between physics and technology. It has many features, such as continuous tunability over a wide wavelength range, excellent optical quality, high power and short pulse capability, and thus has many potential applications. FEL development in China and abroad are mentioned and the Beijing FEL presented to illustrate the physics and technology involved in an FEL project.
International Nuclear Information System (INIS)
The principle is described of a method using low-activity emitters as the primary radiation source for analysis. The selection of the radiation source and the detection methods including the assessment of the applicability of various radiation detectors are discussed. The benefits and the constraints of the method are considered. Practical examples are presented showing the application possibilities of the method for testing the thickness of bearing layers, piston ring coats, lead layers, etc. The possibility is shown of applying the rapid test for the composition of tungsten and chromium alloyed metal materials in testing complex systems. (J.K.).
1974-12-03
International Nuclear Information System (INIS)
An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).
1996-01-01
International Nuclear Information System (INIS)
Many mechanical parts are subjected to stresses and strains that may eventually lead to their failure. In order to prevent the costly delays associated with equipment down-time, many parts have to be tested for weaknesses and defects when machinery is constructed or dismantled for maintenance. These procedures are known as Non-Destructive Testing (NDT) methods. Five types of non-destructive testing methods routinely used are radiographic testing, ultrasonic testing, magnetic particle inspection, liquid penetrant testing and eddy current testing. Out of these five techniques industrial radiography plays an important role in non-destructive testing to reveal interior defects in materials. In radiography almost two-thirds of the radiation reaching the film is scattered radiation which does not form the image of defects. Scattered radiation generated inside and outside a material has a very large effect on sensitivity of flaw ...
1998-02-01
International Nuclear Information System (INIS)
Aqueous deoxyhemoglobin solutions (2 mg/ml) were gamma-irradiated by a "6"0Co source in the presence of methanol, ethanol, 1-butanol and t-butanol under N_2O or argon. The effects of the interaction of the particular alcohol radical species with hemoglobin were determined according to the detected spectral alterations in the visible range. The amounts of stable final products in the form of methemoglobin (MetHb) and the sum of hemichromes and cholehemichromes (Hemichr) were estimated in irradiated preparations. For preparations irradiated under N_2O, the radiation yield for MetHb formation was three-fold lower in the presence of ethanol and 1-butanol [G(MetHb) = 0.33[ compared with preparations irradiated in the presence of t-butanol or without alcohol [G(MetHb) = 1.00[. The yield of hemichromes and cholehemichromes in preparations irradiated under N_2O increased in the order: ethanol (G = 0.38), 1-butanol (B = 0.52), ...
Energy Technology Data Exchange (ETDEWEB)
We report on a recent search for {bar {nu}}{sub e} appearance from stopped {pi}{sup +} {yields} {mu}{sup +}{nu}{sub {mu}} and {mu}{sup +} {yields} e{sup +}{nu}{sub e}{bar {nu}}{sub {mu}} decay made by the LAMPF experiment E645. The appearance of {bar {nu}}{sub e} may occur from {bar {nu}}{sub {mu}} {yields} {bar {nu}}{sub e}, {nu}{sub e} {yields} {bar {nu}}{sub eL}, or {nu}{sub {mu}} {yields} {bar {nu}}{sub eL} oscillations. Appearance may also occur from rare {mu}{sup +} {yields} e{sup +}{bar {nu}}{sub e}{nu}{sub {mu}} decay, which is allowed by a multiplicative lepton charge conservation law. The neutrino energies range from E{sub {nu}} = 0 to 52.8MeV. The neutrino detector, which is located 26.1 meters from the neutrino source, consists of a segmented liquid scintillator and proportional drift tube central detector surrounded by both active and passive shielding. The central detector detects {bar {nu}}{sub e} through the {bar {nu}}{sub e}p ...
1990-01-01
Speckle Reduction for LIDAR Using Optical Phase Conjugation
Energy Technology Data Exchange (ETDEWEB)
Remote detection of chemicals using LIDAR (Light Detection and Ranging) utilizing DIAL (Differential Absorption LIDAR) is now a standard detection technique for both military and civilian activities. We have developed a novel nonlinear optical phase conjugation system that can reduce the effects of speckle noise and atmospheric turbulence on DIAL remote detection systems. We have shown numerically and experimentally that it is possible to increase the signal-to-noise (S/N) ratio for LIDAR systems under certain conditions using optical phase conjugation. This increase in S/N can result in more accurate detection of chemical effluents while simultaneously reducing the time necessary to acquire this information.
2001-02-26
The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous ...
2008-05-01
Effect of decrease of molybdenum radiation hardening at high energy proton irradiation
International Nuclear Information System (INIS)
By method of transmission electron microscopy and measuring of microhardness the peculiarities of influence of radiation defect clusters on molybdenum radiation hardening along range path of protons with 30 MeV initial energy are studied. Decrease effect of hardening growth value and even its absence depending on irradiation dose in the range of 10-20 MeV proton energies in presence of high density of radiation defect dispersed clusters is revealed. It is shown experimentally that this effect is connected with accumulation of hydrogen up to not very high concentrations (not more than 5x10"-"4 at.%) at the expense of elastic and inelastic proton scattering. 5 refs.; 5 figs.
1990-05-22
UK PubMed Central (United Kingdom)
Transient receptor potential (TRP) ion channels have been implicated in detecting chemical, thermal and mechanical stimuli in organisms ranging from mammals to Caenorhabditis elegans....Full Text Available
2008-10-01
UK PubMed Central (United Kingdom)
An ultrasensitive laser-induced fluorescence detector was used with capillary electrophoresis for the study of 5-carboxy-tetramethylrhodamine. The raw signal from the detector provided roughly...Full Text Available
2009-12-15
Novel Human Erythrovirus Associated with Transient Aplastic Anemia
UK PubMed Central (United Kingdom)
Erythrovirus (formerly parvovirus) B19 causes a wide range of diseases in humans, including anemia due to aplastic crisis. Diagnosis of B19 infection relies on serology and the detection of viral DNA...Full Text Available
1999-08-01
A study of neutron room scattering at RPCF
International Nuclear Information System (INIS)
High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National ...
1997-01-05
A study of neutron room scattering at RPCF
Energy Technology Data Exchange (ETDEWEB)
High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National ...
1996-09-01
International Nuclear Information System (INIS)
There are many differences between industrial CT and industrial radiography, such as imaging principle, inspection time, radiation dose and the requirements for operators etc. The national standards for radiation protection of industrial detection are not applicable to the requirements of protection and safety for #gamma#-ray industrial CT to some extent now. In order to standardize the production and use for #gamma#-ray industrial CT, protect the safety of operators and the public, and to promote the popularization and application of #gamma#-ray industrial CT, it is significant to establish the national standards for radiation protection of #gamma#-ray industrial CT as soon as possible. The purpose of this paper is to introduce the contents of this standard, and specify some important terms. Then there is a brief discussion on the existing problems during establishing such standards. At last, the paper ...
2009-03-01
Energy Technology Data Exchange (ETDEWEB)
Water vapor is well known to be a critical component in many aspects of atmospheric research, such as radiative transfer and cloud and aerosol processes. This requires both improved measurements of the columnar water vapor and its profiles in the atmosphere in a wide range of conditions, and adjustment of water vapor parameterizations in radiation codes including the perfection of spectroscopic parameters. In this paper we will present the results of comparison of our calculations and downward solar fluxes measured with Rotating Shadowband Spectroradiometer under conditions of horizontally homogeneous clouds. We also will discuss the sensitivity of atmospheric radiation characteristics to variations of water vapor in the band 940 nm: these results may be useful for development of new methods of retrieval of the total column water vapor content (WVC) in the atmosphere from data of ...
2005-03-18
International Nuclear Information System (INIS)
In this project, measurement of x-ray radiation dose level during radiological examination in Jos university teaching hospital and Plateau State specialist hospital at different locations within the department were carried out using radiation survey meter. The results were converted from micro sievert per hour (#mu#Sv/hr) to milisievert per year (mSv/yr). The radiation levels from the two hospitals visited ranged from 1.3m Sv/yr to 8.4m Sv/yr. This implies that all the radiology departments visited are still operating within the safety limit having less than 20 mSv/yr which is the standard permissible radiation level recommended per year.
2008-10-15
Health risks arising from ionizing radiation and chemical pollutants
International Nuclear Information System (INIS)
In quantifying health risks arising from radiation exposure and synergistic effects promoted by radiation the dose-effect relationship must be used as a basis. Special problems arise in the extrapolation of experimental results or in the treatment of data in the region of low doses administered over long periods of time. For radiation protection purposes, especially manifestations of cancer and genetic effects are significant. The International Commission on Radiation Protection has published binding guiding values on the basis of which to assess the risk of cancer. The cancer risk and genetic risks are estimated for relevant dose ranges and compared with other factors of civilization. For the most important chemical pollutants emitted into the environment the possibilities of impacts arising from synergistic effects are discussed on the basis of the rules and regulations specified ...
1979-10-03
Seasonal and Annual Variation in Activity in Wild Male Meadow Voles (Microtus Pennsylvanicus).
Project ZEUS was designed to characterize the effects of long-term gamma irradiation on free-ranging meadow voles, and to determine the lowest level of radiation at which biological effects are discernible in the population. Behavioural tests are consider...
1980-01-01
Configurable Middleware-Level Intrusion Detection for Embedded Systems
Energy Technology Data Exchange (ETDEWEB)
Embedded systems have become integral parts of a diverse range of systems from automobiles to critical infrastructure applications such as gas and electric power distribution. Unfortunately, research on computer security in general and intrusion detection in particular, has not kept pace. Furthermore, embedded systems, by their very nature, are application specific and therefore frameworks for developing application-specific intrusion detection systems for distributed embedded systems must be researched, designed, and implemented. In this paper, we present a configurable middleware-based intrusion detection framework. In particular, this paper presents a system model and a concrete implementation of a highly configurable intrusion detection framework that is integrated into MicroQoSCORBA, a highly configurable middleware framework developed for embedded systems. By exploiting the ...
2005-06-20
Energy Technology Data Exchange (ETDEWEB)
It is built and tested a transition radiation detector (TRD) to discriminate positrons from protons in the balloon flight TS 93 experiment. It is presented the TRD performance using flight data obtaining a proton-positron rejection factor of the order of 10{sup -3}. During the 24 hour flight, the data in the momentum range 4-50 GeV/c are collected. Using the TRD together with the Silicon calorimeter, it is achieved an overall rejection factor of about 10{sup -5} of positron against the proton background over the entire momentum range.
1995-09-01
Spontaneous radiation decay of weakly bound system in externa field
International Nuclear Information System (INIS)
A new channel of nonlinear ionization of quantum system in a strong laser field is discussed. The probability of spontaneous radiation decay from the ground state in a short-range potential to the final Volkov wave function, is calculated by the first order of the perturbation theory. It is shown that this process at high intensities of the laser field will be comparable with the high harmonic generation. (orig.)
2001-02-01
Radiation therapy for Kasabach-Merritt syndrome. Analysis of unfavorable factors in 5 children
Energy Technology Data Exchange (ETDEWEB)
During the past 10 years, five infants with Kasabach-Merritt syndrome (K-M) receiving radiation therapy were reported. We investigated whether radiation therapy for K-M was useful and what the unfavorable factors of K-M were. During the past 10 years, we have treated five infants with K-M. The syndrome occurred at ages ranging from birth to 4 months. The incidence of female to male ratio was 3:2. Among 5 cases, the site of hemangioma was as follows; shoulder, anterior chest wall, lower abdominal wall, face and neck and inguinal site. All 5 cases received medication to control the coagulopathy including prednisone and blood transfusion at first. Because the platelet count and the bleeding tendency did not improve in any case, these cases received radiation therapy. Total dose ranged from 5 to 10 Gy and fraction-size ranged from 0.5 to 1.75 Gy. Irradiation session ...
1996-03-01
Proton beam therapy for cancer in deep-seated organs
Energy Technology Data Exchange (ETDEWEB)
Radiation therapy has shown definite technical improvement due to application of proton beam irradiation. Clinical results of proton beam therapy also suggested enlargement of indication ranges in radial treatment and decrease of post radiation damages of the treatment of cancers in deep-seated organs. Inprovement of result in cancer therapy could be expected by this treatment technique in the future.
1988-10-01
Infrared stimulated luminescence-decay shape from NaCl as a function of radiation doses
Energy Technology Data Exchange (ETDEWEB)
Dose-dependent behavior of the infrared stimulated luminescence (IRSL) decay from NaCl has been studied experimentally using only one aliquot irradiated with a range of 2-200 Gy {beta}-radiation doses. It was observed that the maximum IRSL intensity has not changed by an increase in dose though the total intensity increased as expected. Considering the possible implications of our findings for dosimeter, the results were compared with the other studies and discussed.
2007-11-15
Energy Technology Data Exchange (ETDEWEB)
The long-range correlation properties in the hourly time variability of geochemical signals measured in a 70 m depth well at Triponzo (Umbria region), are investigated by the detrended fluctuation analysis (DFA). DFA is a data processing method that allows for the detection of scaling behaviors in observational time series even in the presence of non-stationarities. The procedure adopted has allowed for the unambiguous identification of possible correlations among the recorded signals and local earthquakes.
2004-07-01
Radiation hardening of semiconductor parts
International Nuclear Information System (INIS)
This chapter is an overview of total-ionizing-dose and single-event hardening techniques and should be used as a guide to a range of research publications. It should be stressed that there is no clear and simple route to a radiation-tolerant silicon integrated circuit. What works for one fabrication process may not work for another, and there are many complex interactions within individual processes and designs. The authors have attempted to highlight the most important factors and those process changes which should bring improved hardness. The main point is that radiation-hardening as a procedure must be approached in a methodical fashion and with a good understanding of the response mechanisms involved.
International Nuclear Information System (INIS)
In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component ...
2007-08-21
Boron-Lined Neutron Detector Measurements
Energy Technology Data Exchange (ETDEWEB)
Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. Reported here are the results of ...
2009-11-02
The High-Redshift Neutral Hydrogen Signature of an Anisotropic Matter Power Spectrum
An anisotropic power spectrum will have a clear signature in the 21cm radiation from high- redshift hydrogen. We calculate the expected power spectrum of the intensity fluctuations in neutral hydrogen from before the epoch of reionization, and predict the accuracy to which future experiments could constrain a quadrupole anisotropy in the power spectrum. We find that the Square Kilometer Array will have marginal detection abilities for this signal at z~17 if the process of reionization has not yet started; reionization could enhance the detectability substantially. Pushing to higher redshifts and higher sensitivity will allow highly precise (percent level) measurements of anisotropy.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
In principle four different methods (ultrasound, microwaves, {gamma}-radiation and x-rays) are available for the non-destructive testing of refractories. Three of these methods, i.e. ultrasound, microwaves and {gamma}-radiation, are in use by different producers of AZS materials to carry out the quality control of their products. This paper will compare the three methods on the basis of the physical properties, present the existing devices, and show the advantages as well as the limits of the different methods. {gamma}-radiography, the oldest method in use, has one main disadvantage, which is the requirement of protection against radioactive radiation. Furthermore, while cracks and cavities can be detected with this method, structural changes can not be monitored. Therefore, the ultrasonic method was developed that allows to detect variations of porosity and grain size as well as ...
1995-08-01
X-ray fluorescence analysis as auxiliary method of restorers
International Nuclear Information System (INIS)
The principle is described of X-ray fluorescence analysis and the manner of detecting the emitted characteristic radiation. The advantages are presented of radionuclide X-ray fluorescence analysis which consist primarily in the possibility of conducting a totally non-destructive analysis, and of accurate and relatively narrow localization of the analyzed area, the simultaneous qualitative and quantitative determinations of a large number of elements in the order of concentrations 10"1 to 10"-"4%, stability of excitation radiation flux, simple design and relatively low capital costs. The so-called matrix effect is pointed to. A number of examples is given of the use of the cited method, including its use in the analysis of art objects. (J.B.).
1987-09-07
U.S. Government Capabilities to Support Analysis of Gamma Ray Data Submitted by Field Elements
Energy Technology Data Exchange (ETDEWEB)
As radiation detection in the interest of national security becomes increasingly commonplace, inevitable questions arise concerning the interpretation of data from handheld radioisotope identifiers (RIIDs). Field elements typically require fast answers to provide an effective defense and to minimize the impact on legitimate movement of people and goods. To support this need, on-call experts at Sandia, Los Alamos, and Lawrence Livermore national laboratories cooperate in resolving radiation alarms rapidly and accurately. We present an overview, describe the work in progress to improve capabilities, and report on some of the lessons learned.
2005-07-07
To the problem of the Cherenkov radiation of tachyons
International Nuclear Information System (INIS)
It is shown that the Cherenkov radiation of tachyons (CRT) in general case cannot possess axial symmetry with respect to velocity v. This implies that tachyons must be vector particles. Electric dipole is used as a vector characterising the tachyon. Formulas describing the CRT spectrum are derived taking into account the asymmetry for charged tachyon and neutral tachyon dipole with arbitrary orientation with respect to v. It is shown that both types of CRT possess the same integral characteristics. A new integral of motion specific for tachyons is found. Negative results of all attempts to detect the CRT are explained.
Coherent Synchrotron Radiation as a Diagnostic Tool for the LCLS Longitudinal Feedback System
Energy Technology Data Exchange (ETDEWEB)
The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL). To ensure the vitality of FEL lasing, a longitudinal feedback system is required together with other diagnostics. In this paper, we study the possibility of using Coherent Synchrotron Radiation (CSR) from the chicane as a diagnostic tool for bunch length feedback. Studies show that CSR is a good candidate, even for a non-Gaussian, double-horn longitudinal charge distribution as in the LCLS. We further check the possibility for detecting possible microbunching.
2005-06-15
Basic radiation sterilization properties of packaging materials
International Nuclear Information System (INIS)
The foils of various materials were irradiated with "6"0Co with an activity of 11,538 TBq. The minimum radiation dose was 25 kGy. Changes in chemico-physical properties were evaluated by infrared spectroscopy and were not detected after irradiation with 25 kGy. Packing foils were subjected to the following tests: mechanical tests, tests of weld strength, tests of impact resistance, free fall tests, permeability tests for water vapour and microbiological tests. The results of all tests were tabulated. The tests showed that the foils are impermeable for microorganisms and provided the welds are airtight the packed products remain sterile. (J.P.).
1984-11-28
3. Physical foundations and methodology of radionuclide X-ray fluorescence analysis
International Nuclear Information System (INIS)
The physical foundations are described of radionuclide X-ray fluorescence analysis (RXFA) and the table shows the values of K- and L-absorption thresholds and the K- and L-line energies of elements. The calculation of the intensity of characteristic radiation during RXFA proceeds from relations derived for conventional X-ray fluorescence analysis. The choice of the radionuclide source is ruled by the nature of the analysed substance and the used detection technique. The diagram shows the areas of radionuclide sources and the energy of the fluorescence radiation of elements. The table shows the spectra of radionuclide sources suitable for the purposes of RXFA measured by semiconductor Si(Li) and Ge(Li) detectors. (ES).
1983-12-01
Radiation thermocatalytic processes of hydrogen production from water
International Nuclear Information System (INIS)
The results of studies of radiation-thermocatalytic water decomposition in the 673-773 K temperature range in the presence of BeO and titanium Y-type zeolite are presented. It is found that radiation-thermocatalytic processes of hydrogen production from water are characterized by a lower activation energy (55.4 kJ/mole) as compared with thermocatalytic processes (88.4 kJ/mole). The radiation-thermocatalytic process rate in the presence of oxide systems is not an additive sum of rates of radiation-catalytic (at 296-300 K) and thermocatalytic processes of water decomposition. On the basis of obtained results the conclusion is made that during radiation-catalytic decomposition of water in a heterogeneous system BeO + H_2O the main contribution into this process is made by excitons, radiation-chemical yields of excitons and non-equilibrium ...
Modulating factors in the expression of radiation-induced oncogenic transformation
Energy Technology Data Exchange (ETDEWEB)
Many assays for oncogenic transformation have been developed ranging from those in established rodent cell lines where morphological alteration is scored, to those in human cells growing in nude mice where tumor invasiveness is scored. In general, systems that are most quantitaive are also the least relevant in terms of human carcinogenesis and human risk estimation. The development of cell culture systems has made it possible to assess at the cellular level the oncogenic potential of a variety of chemical, physical and viral agents. Cell culture systems afford the opportunity to identify factors and conditions that may prevent or enhance cellular transformation by radiation and chemicals. Permissive and protective factors in radiation-induced transformation include thyroid hormone and the tumor promoter TPA that increase the transformation incidence for a given dose of radiation, and retinoids, ...
1990-08-01
Modulating factors in the expression of radiation-induced oncogenic transformation
International Nuclear Information System (INIS)
Many assays for oncogenic transformation have been developed ranging from those in established rodent cell lines where morphological alteration is scored, to those in human cells growing in nude mice where tumor invasiveness is scored. In general, systems that are most quantitaive are also the least relevant in terms of human carcinogenesis and human risk estimation. The development of cell culture systems has made it possible to assess at the cellular level the oncogenic potential of a variety of chemical, physical and viral agents. Cell culture systems afford the opportunity to identify factors and conditions that may prevent or enhance cellular transformation by radiation and chemicals. Permissive and protective factors in radiation-induced transformation include thyroid hormone and the tumor promoter TPA that increase the transformation incidence for a given dose of radiation, and retinoids, ...
1990-01-01
Programmable radionuclide X-ray fluorescence multi-channel spectrometric analyzer, type 123-1
International Nuclear Information System (INIS)
The whole equipment consists of three separate portable parts: a detector case, a microprocessor and a graphic TV monitor. Magnetic tape memory and an x-y recorder can be connected for recording the measured spectra. The analyzer contains two built-in exchangeable excitation radionuclides. Fluorescence and scattered radiation is detected using a proportional detector. The detected pulses are analyzed by a 256-channel analyzer and the results are shown on the display. The device may be used in mining laboratories, coal and ore dressing plant control rooms or in mining fields of open cast mines for quick detection of the quality of mined or dressed raw materials. (E.S.). 1 fig.
1988-01-01
Therapeutic Applications of Monte Carlo Calculations in Nuclear Medicine
This book examines the applications of Monte Carlo (MC) calculations in therapeutic nuclear medicine, from basic principles to computer implementations of software packages and their applications in radiation dosimetry and treatment planning. It is written for nuclear medicine physicists and physicians as well as radiation oncologists, and can serve as a supplementary text for medical imaging, radiation dosimetry and nuclear engineering graduate courses in science, medical and engineering faculties. With chapters is written by recognised authorities in that particular field, the book covers the entire range of MC applications in therapeutic medical and health physics, from its use in imaging prior to therapy to dose distribution modelling targeted radiotherapy. The contributions discuss the fundamental concepts of radiation dosimetry, radiobiological aspects of targeted radionuclide ...
2003-01-01
Radiation oxidation of phenol in petrochemical waste water. II
International Nuclear Information System (INIS)
The rate was studied of radiation destruction of phenol aqueous solutions at a concentration range of 1 to 100 ppm. Irradiated were model solutions containing additions of some organic and inorganic substances typical of the petrochemical industry. In view of the fact that the radiation destruction kinetics is determined by the amount of dissolved oxygen in the sample and by the phenol concentration, relatively low doses were used. Thus, a sufficient amount of oxygen in the sample and therefore the oxidation mechanism of radiolysis were ensured. The dose-response relationships for phenol destruction were studied using doses of 50, 100, 200 and 400 J.kg"-"1; the limit dose was 500 J.kg"-"1. From the results obtained, a kinetic model was constructed of radiation phenol oxidation in aqueous solutions in the presence of various organic and inorganic additions. (B.S.).
1981-01-01
Effect of ionizing radiation on the properties of PLA packaging materials
International Nuclear Information System (INIS)
Poly(lactic acid) (PLA) is attractive as a substitute for classical polymer packaging material due to its biodegradability and sufficient mechanical and barrier properties. Presented research was focused on the changes of basic mechanical parameters after ionizing irradiation performed with doses in the range of 2.5-25 kGy, commonly used in radiation sterilization and preservation of foods. Two commercial available PLA packaging films were tested. The influence of radiation dose on the mechanical properties - tensile strength and elongation were determined using standardized methods. Radiation resistance of PLA is sufficient for packaging applications. The investigations of gas products of radiolysis of PLA have been made by gas chromatography after electron beam (EB) irradiations. (authors)
Combined radiation and convection in absorbing, emitting, nongray gas-particulate tube flow
Energy Technology Data Exchange (ETDEWEB)
The interaction of thermal radiation with conduction and convection in thermally developing absorbing, emitting, nongray gas-particulate turbulent suspension flow through a circular tube is investigated. The contribution of thermal radiation is obtained through evaluation of the total hemispherical emittance of the particulate cloud and through evaluation of single band absorptances for molecular gases, modified to account for the interaction with the particles. The governing differential equation is derived as a (nonlinear) energy equation, coupled with integral equations to find the thermal radiation contributions. The energy equation is solved numerically by an implicit finite difference method with an iterative procedure. Qualitative results for Nusselt numbers are shown for a variety and range of parameters, such as optical thickness of particulates and single molecular gas bands, relative gas band ...
1987-05-01
Combined radiation and convection in absorbing, emitting, non-Gray gas-particulate tube flow
Energy Technology Data Exchange (ETDEWEB)
The interaction of thermal radiation with conduction and convection in thermally developing absorbing, emitting, non-gray gas particulate turbulent suspension flow through a circular tube is investigated. The contribution of thermal radiation is obtained through evaluation of the total hemispherical emittance of the particulate cloud and through evaluation of single band absorptances for molecular gases, modified to account for the interaction with the particles. The governing differential equation is derived as a (nonlinear) energy equation, coupled with integral equations to find the thermal radiation contributions. The energy equation is solved numerically by an implicit finite difference with its iterative procedure. Qualitative results for Nusselt numbers are shown for a variety and range of parameters, such as optical thickness of particulates and single molecular gas bands, relative gas band ...
1985-01-01
A radiation monitoring system for nuclear fusion devices
International Nuclear Information System (INIS)
Fusion device produces high-level neutrons and #gamma#-rays, which would hazard the safety of the public and workers if the doses would be higher than the regulatory limits because of leakage from the bio-shielding and skyshine. It is essential to monitor the radiation doses in the workshop and the enumerative around fusion devices. A radiation monitoring system (RMS) for full (near and far) areas around a nuclear fusion device has been designed and developed, which can achieve the monitoring and controlling of radiation doses in the workshop area by using the Controller Area Network (CAN), in the institution area by using the Bluetooth Ad hoc network based on a new tree topology formation and routing protocol and in a long range environment by using the General Packet Radio Service (GPRS) network. (authors)
2005-12-01
Energy Technology Data Exchange (ETDEWEB)
An analyser for detecting explosives has at least one neutron source and a plurality of gamma ray detectors. An article to be analysed is moved adjacent the source and detectors and is subjected to neutrons which generate gamma rays from any nitrogen in the article. The gamma rays are detected and analysed to determine the nitrogen concentration within the article. In order to achieve an area of uniform detection there are a plurality of detectors equidistant both from the or each source and from the article to be analysed. In order to avoid a decrease in sensitivity away from the source(s) and detectors there may be a second opposing array of source(s) and detectors on the opposite side of the article. For greatest uniformity of detection, a source in one array opposes a detector in the other array and vice versa. Transmission of radiation from the analyser is kept at safe levels ...
1991-03-13
Coated semiconductor devices for neutron detection
Energy Technology Data Exchange (ETDEWEB)
A device for detecting neutrons includes a semi-insulated bulk semiconductor substrate having opposed polished surfaces. A blocking Schottky contact comprised of a series of metals such as Ti, Pt, Au, Ge, Pd, and Ni is formed on a first polished surface of the semiconductor substrate, while a low resistivity ("ohmic") contact comprised of metals such as Au, Ge, and Ni is formed on a second, opposed polished surface of the substrate. In one embodiment, n-type low resistivity pinout contacts comprised of an Au/Ge based eutectic alloy or multi-layered Pd/Ge/Ti/Au are also formed on the opposed polished surfaces and in contact with the Schottky and ohmic contacts. Disposed on the Schottky contact is a neutron reactive film, or coating, for detecting neutrons. The coating is comprised of a hydrogen rich polymer, such as a polyolefin or paraffin; lithium or lithium fluoride; or a heavy metal fissionable material. By varying the coating thickness and ...
2002-01-01
Energy Technology Data Exchange (ETDEWEB)
Genomic instability can be produced by ionising radiation, so-called radiation-induced genomic instability, and chemical mutagens. Radiation-induced genomic instability occurs in both germinal and somatic cells and also in the offspring of irradiated individuals, and it is characterised by genetic changes including chromosomal rearrangements. The majority of studies of trans-generational, radiation-induced genomic instability have been described in the male germ line, whereas the authors who have chosen the female as a model are scarce. The aim of this work is to find out the radiation-induced effects in the foetal offspring of X-ray-treated female rats and, at the same time, the possible impact of this radiation-induced genomic instability on the action of a chemical mutagen. In order to achieve both goals, the quantity and quality of chromosomal damage were ...
2008-04-02
Distributed radiation protection console system
International Nuclear Information System (INIS)
Radiation exposure control is one of the most important aspects in any nuclear facility . It encompasses continuous monitoring of the various areas of the facility to detect any increase in the radiation level and/or the air activity level beyond preset limits and alarm the O and M personnel working in these areas. Detection and measurement of radiation level and the air activity level is carried out by a number of monitors installed in the areas. These monitors include Area Gamma Monitors, Continuous Air Monitors, Pu-In-Air Monitors, Criticality Monitors etc. Traditionally, these measurements are displayed and recorded on a Central Radiation Protection Console(CRPC), which is located in the central control room of the facility. This methodology suffers from the shortcoming that any worker required to enter a work area will have to inquire about the ...
2004-02-01
Plane electrode device for multiwire detector for ionizing radiations
International Nuclear Information System (INIS)
A multiwire proportional counter type detector with thin slits instead of wires is presented. It can detect either charged particles (positive or negative) or radiation. The detector can be used as a counter or as an image converter. In radiography, it can replace photographic film or TV camera systems. It can also be used to measure particle or radiation energy. The slits which replace wires in the anode are introduced between two parallel microstrip conductors with different potentials. A quasi-polar electric field is produced between these strips. To obtain high fields, the slits are extremely narrow. Microstrips less than a micron can be obtained, giving structural dimensions of a few microns, i.e., 100 times smaller than the spacing in a classic wire anode.
1986-07-01
Use of signal delay of one of detectors in two-channel radiometric flaw detector
International Nuclear Information System (INIS)
A possibility is considered or reducing the surface heterogeneity effect of an item being tested on the result of radiation flaw detection by means of signal delay of one of detectors in a two-channel radiometric flaw detector. The exposure of a translationally moving item has been studied as well as an external exposure of a rotating hollow item.
Test of superconducting Nb/Al bilayers as particle detectors
Energy Technology Data Exchange (ETDEWEB)
Superconducting thin film particle detectors can be very attractive due to the low sensitivity to radiation damage. We describe the fabrication procedure and the characterization of Nb/Al bilayers as particle detectors. First steady and dynamical results are reported from tests of 5 MeV alpha-particle detection.
2000-04-07
Search for tachyons associated with extensive air showers in the ground level cosmic radiation
International Nuclear Information System (INIS)
Events detected in a shielded plastic scintillation counter occurring in the 26 microsec preceding the arrival of an extensive air shower at ground level with local electron density or = 20 m to the -2 power and the 240 microsec after its arrival have been studied. No significant excess of events (tachyons) arriving in the early time domain have been observed in a sample of 11,585 air shower triggers.
1985-08-01
Lysis of phespholipid membranes with radiation-induced free radicals
International Nuclear Information System (INIS)
Phospholipid vesicles were found to be lysed by exposure to free radicals derived from irradiated glycine and galactose. The decomposition yield increased with vesicle concentration, and attained values of 0.0006 vesicles destroyed per radical added. Ionic charge at the phospholipid end groups was found to be more important than degree of unsaturation in determining this yield. Radicals derived from irradiated serine and alanine had no detectable lytic action at the vesicle concentrations tested.
1977-05-01
In vivo99mTc-HYNIC-annexin V imaging of early tumor apoptosis in mice after single dose irradiation
UK PubMed Central (United Kingdom)
BackgroundApoptosis is a major mode of hematological tumor death after radiation. Early detection of apoptosis may be beneficial for cancer adaptive treatment. 99mTc-HYNIC-annexinV...Full Text Available
Gene rearrangement and radiation carcinogenesis
International Nuclear Information System (INIS)
The development of leukemia and thyroid cancer is characterized by activation of the abl oncogene and ret oncogene, respectively. In order to clarify the relationship between these gene aberrations and radiation, the pro-myelogenous leukemia-derived cell line HL60 and the thyroid cancer-derived cell line 8505C, were irradiated in vitro with 100Gy of X-rays. RNA was then extracted from 10"8 cells of the respective cell lines and examined by the reverse transcription PCR method for rearrangements of abl and ret genes. Five kinds of positive bands were observed in the HL-60 cells irradiated with 100Gy of X-ray. Similarly, six positive bands were also observed in the 8505C cells irradiated with 100Gy. In vitro X-irradiation activation of oncogenes found in radiation induced cancers imply that gene rearrangement by X-rays is involved in the development of malignant tumors. Furthermore, in an experiment to detect ...
1993-11-01
Estimation of errors provided with dead times of roentgen digital tomography
International Nuclear Information System (INIS)
Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computer tomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained
International Nuclear Information System (INIS)
The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 (16N) and Oxygen-19 (19O) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of 19O and 16N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high ambient radiation level even though sensitivity is appreciably good. For detector position in RB in the accessible ...
2006-11-13
An experimental plan for improvement of failed fuel monitoring system in CANDU reactor
Energy Technology Data Exchange (ETDEWEB)
An experimental plan for improving the problems of failed fuel location system in Wolsung Unit-2 reactors was established. It is not possible to make an experiment on the failed fuel monitoring nuclides in the cold laboratories because they have very short half life. Therefore, the experiments can be only carried out at the existing monitoring system under reactor operation. For that reason, an experimental plan was drawn up for installing the radiation detection system on reactor site.
2003-10-01
The effect of irradiation on packaging materials
International Nuclear Information System (INIS)
Ionizing radiation, mainly in the form of #gamma#-rays from the radioisotope cobalt 60, is being used increasingly for the inactivation of contaminants in cosmetic and toiletry preparations. The treatment is applied to the product in its final pack, and therefore, it is important to recognize that the properties of the packaging materials could be affected, particularly if high radiation doses are used. The stability of a wide range of materials is discussed. The nature and extent of chemical and physical changes in plastics very much depends on the presence of antioxidants and other additives, and on the environmental conditions during irradiation. Some useful information is available from research into the use of radiation for the preservation of food - many films and laminates have been cleared for use in the United States. The low radiation doses used for the control of ...
ESR/Alanine dosimetry on Wolsung Unit 1
Energy Technology Data Exchange (ETDEWEB)
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement ...
2007-07-01
ESR/Alanine dosimetry on Wolsung Unit 1
International Nuclear Information System (INIS)
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement ...
2007-05-10
Remote sensing of the atmosphere by resonance Raman LIDAR
Energy Technology Data Exchange (ETDEWEB)
When in resonance, Raman scattering exhibits strong enhancement ranging from four to six orders of magnitude. This physical phenomenon has been applied to remote sensing of the Earth`s atmosphere. With a 16 inch Cassegrain telescope and spectrometer/ CCD-detector system, 70-150 ppm-m of SO{sub 2} in the atmosphere has been detected at a distance of 0.5 kilometer. This system can be used to detect/monitor chemical effluence in the atmosphere by their unique Raman fingerprints. Experimental result together with detailed resonance Raman and atmospheric laser propagation effects will be discussed.
1994-12-01
Precise Measurement of the Neutron Magnetic Form Factor G{sub M}{sup n} in the Few-GeV{sup 2} Region
The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q{sup 2}=1.0-4.8 GeV{sup 2} with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.
2009-05-15
Precise Measurement of the Neutron Magnetic Form Factor GMn in the Few-GeV2 Region
International Nuclear Information System (INIS)
The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q2=1.0-4.8 GeV2 with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.
2009-05-15
International Nuclear Information System (INIS)
The detection efficiency of #alpha# particles of "2"1"4Po 7.69 MeV and "2"1"8Po 6.00 MeV in measuring radon daughters were determined through the data which were measured with long-lived #alpha# standard source and radon daughter standard source and with curve-fitting method of general formulation. The indeterminacy was #<=#2.5% and #<=#2.7% respectively. Their ranges in filter membrane were also determined, and the effect of the indeterminacy on the self-absorption factors was #<=#1.3%.
5 GHz 200 Mbit/s radio over polymer fibre link with envelope detection at 650 nm wavelength
DEFF Research Database (Denmark)
All-optical envelope detection of a 5 GHz 200 Mbit/s modulated radio frequency signal is achieved using a 650 nm resonant cavity light emitting diode. Error-free transmission is achieved over a 50 m-long link of 1 mm diameter graded index polymer optical fibre (POF). The presented system has potential applications in low cost and low complexity short range wireless and wireline POF-based transmission links.
2008-01-01
Gravitational waves interferometer and the VIRGO project
Radio, optical and X-rays telescopes are improving our knowledge of deep space. All these telescopes detect electromagnetic radiation at various frequencies. But a different kind of radiation is generated in the deeper space; it is the gravitational one. Gravitational waves change the space-time metric. As a consequence, GW telescopes should detect an extremely small strain (h < 10/sup -21/) of the geometry of a reference frame; if the frame has a reference dimension (L) of some kilometers, the deformation amplitude ( Delta L = h * L) is limited to 10/sup -16/ meters. Laser interferometers are the most suitable devices to make precise measurements of distances. Their resolution is limited by the laser wavelength ( lambda = 10/sup -6/ meters) and by the light wave-shift detection capability ( Delta Phi = 1 ppb). These theoretical limits are strongly degraded by different noise ...
2002-01-01
Computed radiography. Evaluation of its role in the mass survey for lung cancer: Phantom study
Energy Technology Data Exchange (ETDEWEB)
In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in the retrocardiac and subdiaphragmatic regions, respectively. This may have ...
1987-12-01
International Nuclear Information System (INIS)
In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in the retrocardiac and subdiaphragmatic regions, respectively. This may have ...
1987-01-01
Radioanalytical methods of rare earth element determination
International Nuclear Information System (INIS)
Instrumental neutron activation analysis (INAA) and radionuclide X-ray fluorescence analysis (RXFA) were used for the determination of rare earth elements. For INAA, solution obtained by sample decomposition was dripped onto filter paper, enclosed and sealed into a polyethylene foil. The sample was activated in reactor WWR-S over a period of 4 to 6 hours with a neutron fluence of 10"1"3cm"-"2. Gamma radiation measurement was carried out with a planar and a coaxial HP-Ge detector in three decay periods. La, Ce, Nd, Sm, Eu, Gd, Tb, Ho, Tm, Yb and Lu were determined. The advantage of the method is its accuracy and high sensitivity, the disadvantage is the time-consuming analysis. The RXFA method was used as a rapid and operative method for the analysis of loose ore samples, aqueous and organic solutions of rare earth elements. For exciting X-ray radiation, "2"4"1Am was used and the radiation of K-lines was ...
1989-06-01
Development of a dual-detector X-ray imaging system for phase retrieval study
International Nuclear Information System (INIS)
Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two detectors, respectively ...
2007-01-01
Aging and compatbility of TNF-doped mylar
Energy Technology Data Exchange (ETDEWEB)
TNF-doped Mylar is a new radiation-hard dielectric that has recently been qualified as a viable substitute for Mylar in capacitors. The advantage of TNF-doped Mylar is that it satisfies both the nuclear safety and radiation hardness requirements of weapons. Mylar is not radiation-hard. Aging and compatibility studies were carried out to insure that (1) TNF does not diffuse from the film during fabrication of the capacitor or during storage; and (2) there are no compatibility problems with aluminum foil (the conductor) or Fluorinert (the secondary dielectric). Losses of TNF were barely detectable during the vacuum bakes used in fabricating capacitors or during accelerated aging tests carried out below T{sub g} (70C) over a two year period in air. In other accelerated tests, no compatibility problems were detected with aluminum or Fluorinert. TNF-doped Mylar is now being used in the ...
1990-01-01
Introduction Uchide and Ide [SSA Spring Meeting, 2009] proposed a new framework for studying the scaling and overall nature of earthquake rupture growth in terms of cumulative moment functions. For better understanding of rupture growth processes, spatiotemporally local processes are also important. The nature of high-frequency (HF) radiation has been investigated for some time, but its role in the earthquake rupture process is still unclear. A wavelet analysis reveals that the HF radiation (e.g., 4 - 32 Hz) of the 2004 Parkfield earthquake is peaky, which implies that the sources of the HF radiation are isolated in space and time. We experiment with applying a matched filter analysis using small template events occurring near the target event rupture area to test whether it can reveal the HF radiation sources for a regular large earthquake. Method We design a matched filter for multiple components and ...
2009-12-01
Some characteristics of a novel direct thermal to optical energy converter medium
Energy Technology Data Exchange (ETDEWEB)
We have measured some of the optical characteristics of a novel energy conversion medium, over a range of compositions in the system Yb[sub 2]O[sub 3][minus]Al[sub 2]O[sub 3], which we have fabricated by a proprietary process. These specimens have good resistance to thermal shock, are durable, and are mechanically and chemically stable. The integrated emission of light generated by these unoptimized specimens when heated with a propane-air flame and detected with a silicon photodetector ranged up to 1.88 watts/cm[sup 2]. The emission spectrum from these specimens when heated with a propane-air flame and detected with a germanium photodetector shows a narrow band in the vicinity of 1 micron.
1995-01-05
Use of Multiwalled Carbon Nanotubes as a SPE Adsorbent for Analysis of Carfentrazone-Ethyl in Water
British Library Electronic Table of Contents (United Kingdom)
Solid-phase extraction and gas chromatography with electron-capture detection has been used for sensitive, simple, and reliable analysis of carfentrazone-ethyl residues in water. Carfentrazone-ethyl was enriched by use of multiwalled carbon nanotubes (MWCNT), a new adsorptive material. Several conditions affecting recovery of the analyte, for example polarity and volume of eluents, pH of water samples, and sample volume, were studied. Recovery from fortified samples, linear range, and limit of detection were evaluated. The results showed that MWCNT are an efficient SPE adsorbent for preconcentration of carfentrazone-ethyl in water. Under the optimized SPE conditions, recovery of carfentrazone-ethyl from fortified water was 81.49?91.08%, with RSD from 1.66 to 8.21%. The limits of detection ...
2009-01-01
The KCAL VERA 22 GHz calibrator survey
We observed at 22 GHz with the VLBI array VERA a sample of 1536 sources with correlated flux densities brighter than 200 mJy at 8 GHz. One half of target sources has been detected. The detection limit was around 200 mJy. We derived the correlated flux densities of 877 detected sources in three ranges of projected baseline lengths. The objective of these observations was to determine the suitability of given sources as phase calibrators for dual-beam and phase-referencing observations at high frequencies. Preliminary results indicate that the number of compact extragalactic sources at 22 GHz brighter than a given correlated flux density level is twice less than at 8 GHz.
2011-01-01
Hybrid Camera Surveillance System Using Robust Human Detection
We propose a novel surveillance system that uses hybrid camera network. The system contains a panorama camera and PTZ cameras to take the wide range images and face images at high enough resolution for identification tasks. The robust human detection methods include robust background subtraction method (RRC), skin color segmentation and face tracking method. First, the system detects persons from a panorama image, and then the detailed face images are obtained with the PTZ cameras. The PTZ cameras can track the faces using the four directional features and the relaxation matching. In addition, the system has automatic camera position calibration feature. Thus, the user can use the system without any troublesome settings.
2007-01-01
Graphene-Pt nanocomposite for nonenzymatic detection of hydrogen peroxide with enhanced sensitivity
British Library Electronic Table of Contents (United Kingdom)
A sensitive hydrogen peroxide (H2O2) sensor was fabricated based on graphene-Pt (GN-Pt) nanocomposite. The GN-Pt was synthesized by photochemical reduction of K2PtCl4 on GNs, and characterized by atomic force microscope (AFM), transmission electron microscope (TEM), and energy-dispersive X-ray spectroscopy (EDS). Electrochemical investigations indicated that the GN-Pt exhibited a high peak current and low overpotential towards the reduction of H2O2. The GN-Pt modified glass carbon electrode displayed a wide linear range (2-710mM), low limit of detection (0.5mM) and good selectivity for detection of H2O2 with a much higher sensitivity than that of Pt nanoparticles or graphene modified electrode.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
A controlled field pilot has been developed in Bozeman, Montana, USA, to study near surface CO2 transport and detection technologies. A slotted horizontal well divided into six zones was installed in the shallow subsurface. The scale and CO2 release rates were chosen to be relevant to developing monitoring strategies for geological carbon storage. The field site was characterized before injection, and CO2 transport and concentrations in saturated soil and the vadose zone were modeled. Controlled releases of CO2 from the horizontal well were performed in the summers of 2007 and 2008, and collaborators from six national labs, three universities, and the U.S. Geological Survey investigated movement of CO2 through the soil, water, plants, and air with a wide range of near surface detection techniques. An overview of these results will be presented.
2009-10-20
Characterization of Radiation Instruments at the Summit of Mt. Fuji
International Nuclear Information System (INIS)
The opportunity of exposure to high-energy radiation up to GeV is increasing as in civilian aircrafts and at particle accelerators. The transport of such energetic particle is still difficult to describe precisely and thus verification by measurement using a well characterized instrument is indispensable for reliable dosimetry. However, no reference calibration field has been established for the high-energy range. We thus propose to use a facility at the summit of Mt. Fuji (3776 m in altitude; N35.36o, E138.73o), the highest place in Japan, for characterization of radiation instruments that are possibly used in high-energy radiation fields. For demonstration of the effectiveness, two moderator-type neutron monitors (NCN1 and WENDI-II) having different energy response functions were employed for cosmic-ray neutron measurements in the summer of 2009. In comparison with numerically simulated values, it was ...
2010-12-01
International Nuclear Information System (INIS)
Aim: To create nomograms for renal size as measured from DMSA renal studies, and to test the nomograms for their ability to separate normal from abnormal kidneys. Method: Renal length was measured from posterior oblique views and renal area from posterior views. Results from 253 patients with bilateral normal kidneys were used to create nomograms for renal size relative to patient age, body height, weight or body surface area (BSA). The nomograms enclosed 95% of the normal kidneys, thus indicating the range for 95% confidence limits, and hence the specificity. Each nomogram was then tested against 46 hypertrophied kidneys and 46 damaged kidneys. Results: The results from nomograms of renal length and renal area, compared to age, body height, body weight and BSA are presented. For each nomogram, the range is presented as a fraction of the mean value, and the number of abnormal kidneys (hypertrophied or damaged) outside the normal ...
2002-09-01
International Nuclear Information System (INIS)
The regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from January 7 to February 8, 1985. The summary of the results of this regular inspection is as follows. The facilities as the object of inspection were radiation control facilities and waste facilities. On these facilities as the object of inspection, the appearance, disassembling, functional, performance and other inspections were carried out, and as the results, abnormality was not found at all. The works related to this regular inspection were accomplished within the range of the allowable radiation dose based on the relevant laws. (Kako, I.).
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
Measurements of the photon angular distribution of Radiative Electron Capture into the M shell have been performed with He-like uranium ions in the range 110-140 MeV/u. In addition, L REC was studied at a projectile energy of 140 MeV/u. In both cases, the experimental data show an asymmetry around 90 and agree well with a fully relativistic theory. (orig.) 15 refs.
1995-10-01
Forward directed Smith-Purcell radiation from relativistic electrons
International Nuclear Information System (INIS)
The requirements for the generation of forward directed Smith-Purcell emission from relativistic electrons are introduced, and the first experimental evidence of this phenomenon is presented. The experiments were conducted with a 2.8 MeV/c electron beam interacting with a 1 cm period grating. Radiation emitted in two bands with wavelengths ranging from 600 to 650 #mu#m and 1.2 to 1.7 mm were measured. Grating period to wavelength ratios were as high as 16. The measured intensities are higher than that predicted by incoherent emission.
Preliminary studies on the detection of irradiated prawns using 2-alkylcyclobutanones
Energy Technology Data Exchange (ETDEWEB)
The use of ionising radiation for the preservation of food has been under investigation for many years but has yet to receive worldwide acceptance. Although irradiation can be carefully controlled, it is generally accepted that the development of a test or tests for the detection of irradiated food would enhance consumer confidence and might help to enforce labelling regulations. The 2-alkylcyclobutanones are reported to be the only cyclic compounds formed as the products of the radiolysis of saturated and unsaturated triglycerides. The synthesis of 2-dodecylcyclobutanone (DCB) and 2-tetradecylcyclobutanone (TCB), which are formed from palmitic and stearic acid respectively following irradiation, has been carried out and using irradiated chicken meat as the model for a high-lipid containing food, both cyclobutanones have been extracted with hexane and then identified using gas chromatography/mass spectrometry (GC/MS). DCB and TCB have been ...
1996-12-31
International Nuclear Information System (INIS)
We have studied in detail the gamma radiation induced changes in the electrical properties of the (TeO_2)_0_._9 (In_2O_3)_0 _._1 thin films of different thicknesses, prepared by thermal evaporation in vacuum. The current-voltage characteristics for the as-deposited and exposed thin films were analysed to obtain current versus dose plots at different applied voltages. These plots clearly show that the current increases quite linearly with the radiation dose over a wide range and that the range of doses is higher for the thicker films. Beyond certain dose (a quantity dependent on the film thickness), however, the current has been observed to decrease. In order to understand the dose dependence of the current, we analysed the optical absorption spectra for the as-deposited and exposed thin films to obtain the dose dependences of the optical bandgap and energy width of band tails of the localized states. ...
2011-02-01
Empirically Consistent Electroweak Radiative Corrections with the Two-Higgs Doublet Model
The electroweak radiative correction, which turned out to be marginal within the standard electroweak model having the minimal Higgs sector in view of the present experimental information, fits well the experiment when the Higgs sector is extended to have two Higgs doublets. We predict the range where the charged and CP odd Higgs boson masses would lie, taking the two CP even neutral Higgs boson masses to be degenerate which makes the analysis in multiparameter space feasible. It is shown that the mass of neutral Higgs doublet boson can arbitrarily be large consistently with the $W$ mass, if the charged Higgs boson is present and it's mass lies in some appropriate ranges.
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
Our objective was to evaluate the feasibility of ultra-low-dose scanning for multislice CT colonography in the detection of colorectal lesions. Twenty-seven patients (14 men, 13 women) with clinical indication for conventional colonoscopy were recruited. Multislice spiral CT (Somatom Plus 4 Volume Zoom, Siemens, Germany) examinations were performed after standard oral colonoscopic preparation and colonic distension with room air. Images were acquired using 2.5-mm collimation, 3.0-mm slice thickness, standard reconstruction kernel, 140 kVp, and 10 mAs. Supine and prone acquisitions were obtained in all patients. Images were analyzed on a workstation by two gastrointestinal radiologists. Conventional colonoscopy was performed on the same day in all patients and represented the standard of reference. Total radiation exposure was also calculated. All colorectal cancers were correctly identified at CT colonography (9 of 9, sensitivity 100%). The CT ...
2003-06-01
International Nuclear Information System (INIS)
Full text: DNA rearrangement events leading to chromosomal aberrations are central to ionizing radiation-induced cell death. Although DNA double-strand breaks are probably the lesion that initiates formation of chromosomal aberrations, little is understood about the molecular mechanisms that generate and modulate DNA rearrangement. Examination of the sequences that flank sites of DNA rearrangement may provide information regarding the processes and enzymes involved in rearrangement events. Accordingly, we developed a method using inverse PCR that allows the detection and sequencing of putative radiation-induced DNA rearrangements in defined regions of the human genome. The method can detect single copies of a rearrangement event that has occurred in a particular region of the genome and, therefore, DNA rearrangement detection does not require survival and continued multiplication of ...
2003-08-17
International Nuclear Information System (INIS)
The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For detector position out side the RB containment, the travel time for ...
2005-11-23
Temperature stabilization, ocean heat uptake and radiative forcing overshoot profiles
British Library Electronic Table of Contents (United Kingdom)
Political leaders in numerous nations argue for an upper limit of the global average surface temperature of 2 K above the pre-industrial level, in order to attempt to avoid the most serious impacts of climate change. This paper analyzes what this limit implies in terms of radiative forcing, emissions pathways and abatement costs, for a range of assumptions on rate of ocean heat uptake and climate sensitivity. The primary aim is to analyze the importance of ocean heat uptake for radiative forcing pathways that temporarily overshoot the long-run stabilization forcing, yet keep the temperature increase at or below the 2 K limit. In order to generate such pathways, an integrated climate-economy model, MiMiC, is used, in which the emissions pathways generated represent the least-cost solution o...
2011-01-01
Radiative Breaking of Gauge Symmetries in the MSSM and in its Extensions
The radiative electroweak symmetry breaking, the b-\\tau Yukawa and gauge couplings unification in the MSSM and its SU(5) extensions are studied in detail. In the framework of the two-loop renormalization group equations both low- and high-energy threshold effects are included. In the case of the minimal SU(5), the values of \\alpha_s obtained are somewhat larger than the experimental average. The Peccei-Quinn version of the missing-doublet SU(5) model generally predicts smaller values of \\alpha_s and b-\\tau unification, in excellent agreement with all low energy experimental data. We also study the generation of the GUT scale through radiative corrections in the context of an R-symmetric ``flipped" SU(5) x U(1)_X model and we find that this is possible in a certain range of values of the parameter space.
1998-01-01
Chemistry and technology of radiation processed composite materials
International Nuclear Information System (INIS)
Composite materials of synthetics (based on monomers, oligomers and thermoplastics) and of natural polymers (wood and other fibrous cellulosics) prepared by radiation processing, offer valuable structural materials with enhanced coupling forces between the components. The applied polymer chemistry of such composites shows several common features with that of radiation grafting. E.g. the polymerization rate of oligomer-monomer mixtures in wood remains in most cases proportional to the square-root of the initiating dose-rate, just as in the simultaneous grafting, demonstrating that the chain termination kinetics remain regularly bimolecular in the corresponding dose-rate ranges. In the processing experiences of such composites, low dose requirement, easy process-control, and good technical feasibility have been found for composites of wood with oligomer-monomer mixtures, for coconut fibres with unsaturated polyesters and for ...
1984-10-01
Chemistry and technology of radiation processed composite materials
International Nuclear Information System (INIS)
Composite materials of synthetics (based on monomers, oligomers and thermoplastics) and of natural polymers (wood and other fibrous cellulosics) prepared by radiation processing, offer valuable structural materials with enhanced coupling forces between the components. The applied polymer chemistry of such composites shows several common features with that of radiation grafting, e.g. the polymerization rate of oligomer-monomer mixtures in wood remains in most cases proportional to the square-root of the initiating dose-rate, just as in the simultaneous grafting, demonstrating that the chain termination kinetics remain regularly bimolecular in the corresponding dose-rate ranges. In the processing experiences of such composites, low dose requirement, easy process-control, and good technical feasibility have been found for composites of wood with oligomer-monomer mixtures, for coconut fibres with unsaturated polyesters and for ...
1984-10-01
A VUV prism spectrometer for RICH radiator refractometry
A prism spectrometer has been developed to operate in the VUV wavelength range from 120 to 200 nm. It can be used as a pre- disperser in conjunction with a Fabry-Perot based gas refractometer. This instrument has also been used to measure the refractive index of the liquid radiator C/sub 6/F/sub 14/ in various spectral lines. This radiator is used in the RICH detectors of the DELPHI experiment and has been proposed for ALICE, and LHCb experiments. The spectral resolution of the system is improved as the wavelength decreases and the data are consistent with a wavelength accuracy about 0.4 nm at 140 nm. The results for the dispersion curve of the above liquid are presented. (17 refs).
2000-01-01
Self-assessment of current knowledge in nuclear medicine (second edition)
Energy Technology Data Exchange (ETDEWEB)
In this updated second edition, the order of contents of the textbook has been reorganized. It has been divided into main parts: Basic Science and Clinical Nuclear Medicine. Basic Science, Part I, encompasses basic physics, radiation protection, interaction of radiation with matter and radiation detection, imaging, nuclear pharmacy, and radiation biology. Part II, Clinical Nuclear Medicine, covers the central nervous system, bone, gastroenterology (liver/spleen), cardiovascular system, pulmonary system, genitourinary system, thyroid and endocrine systems, gallium studies, radioassay, hematology, and therapy. The total number of pages of the current edition is increased to 250 from the 213 of the first edition but there are fewer questions because those in the basic science area have been carefully selected to 60 of the original 98 questions. Compared with the previous edition, there ...
1981-01-01
Salmonella radicidation of poultry carcasses
International Nuclear Information System (INIS)
This thesis reports investigations using gamma-radiation to decontaminate poultry carcasses. The application to foods of doses of ionizing radiation sufficient to reduce the number of viable specific non-sporeforming pathogenic microorganisms so that none is detectable in the treated food by any standard method is termed radicidation. The doses used in this study were at such a level that no undesirable or unfavourable side-effects occurred. The effects of these doses were studied on salmonellae and other microorganisms present in, or associated with poultry carcasses and in liquid and on solid culture media as well. Decimal reduction (D_1_0) values were estimated. These represent the dose (kGy) required to achieve a reduction in initial colony count from N_0 to 0.1 N_0. Together with the estimation of the numbers of Salmonella present per carcass the data were used to predict the effect of an ionizing ...
2005-09-22
Recurrent plot analysis of discharge sequences in tracking test of polybutylene polymers
Energy Technology Data Exchange (ETDEWEB)
Polymers are required to use in radiation environments as insulation materials. However, they often suffer from tracking failure. There is an increasing demand to evaluate radiation effects on dielectric performance. This paper presents a recurrence plot (RP) approach to analyse surface discharge sequences of gamma-ray irradiated polymer materials based on tracking test. Studying the non-linear characteristics of discharge sequences can assist in understanding the underlying mechanism of the discharge process. Discharge sequences of the test are extended to m-dimensional phase space by using the phase space reconstructed method. As test samples, polybutylene terephthalate (PBT) and polybutylene naphthalate (PBN) were irradiated to 100 kGy and then up to 1 MGy with a dosage rate of 10 kGy h{sup -1} by using a {sup 60}Co gamma source. The tracking tests were carried out according to the test method described in IEC60112. It is found that the RPs ...
2008-10-07
Low dose effects - is the fear more dangerous than the radiation?
Energy Technology Data Exchange (ETDEWEB)
The use of hypothesis which assumes a dose / harmful effect relationship without a limit allows the calculation of risks attributable to doses too small to produce detectable, harmful biological effects. The daughter product of this hypothesis is ALARA concept which requires that the dose received is kept as low as reasonably achievable. This concept of prudent avoidance is generally accepted by international radiation protection organisations and universally applied by radiation health professionals. The acceptance of a hypothesis which assumes that a single nuclear event can cause carcinogenesis, has generated levels of anxiety which may have resulted in significant detriment to those possibly exposed to ionising radiation. The anxiety generated may have caused more detriment and a higher death rate than the worst case ` theoretical` value calculated using the Linear or Quadratic Linear Hypothesis. ...
1996-01-01
Energy Technology Data Exchange (ETDEWEB)
Safety standards for exposure to radiofrequency radiation must be based upon biologic consequences of exposure to such environments. Behavioral-based measures are considered to be the most-sensitive indices of biological effects. Current safety guidelines are based upon average power density and may not be relevant to the high-peak-power, short pulse width microwave radiation produced by newly developed high peak power microwave sources. The effects of exposure to high-peak-power radiation on reflexive responding and motor function in Fischer 344/N rats were assessed by measuring startle and general activity, and disruption of on-going performance of a rotarod task, respectively. The emitter used was the TEMPO repeat pulse axially extracted vircator. Exposure to single pulses resulted in significant startle responses. Exposure to 1 pps for 10 s produced significant alterations in baseline activity and marked disruption of ...
1988-03-01
Radiation processed sawdust-clay-plastic composite. [Gamma radiation
Energy Technology Data Exchange (ETDEWEB)
Wood sawdust has been applied to manufacture the sawdust-clay-plastic composite (SDCPC) by radiation process for the purpose of disposing large amount of wood sawdust waste material. The process comprises the impregnation of liquid vinyl monomers into the completely dried molded sawdust-clay specimens followed by exposure to Co-60 gamma-radiation to induce graft-copolymerization of the impregnated vinyl monomers onto the sawdust-clay matrix. The comonomer system of unsaturated polyester and vinyl compounds was found to be the ideal impregnating monomer for the preparation of the SDCPC from the viewpoint of the technological and economical advantages. The SDCPC material has a variety of the sawdust content which enables the composite to have wide range of mechanical properties, e.g., 410 to 1100 kg/cm/sup 2/ in compressive strength, 120 to 380 kg/cm/sup 2/ in tensile strength and 0.32 to 4.41 kg/mm/sup 2/ in static bending ...
1983-01-01
Electromagnetic radiation unmasked
International Nuclear Information System (INIS)
This article describes the nature of the electromagnetic waves, what they are and how do they affect us. Current concern is focused on exposure to low level power-frequency magnetic fields like microwave radiation from mobile phones and leaking microwave ovens; high power radiation from defence and airport radars; fields close to high voltage transmission lines; radio frequency fields from industrial welders and heaters and DC magnetic fields in aluminium smelters. These fields with frequency less than 300 GHz do not carry sufficient energy to break chemical bonds and it is assumed that they cannot damage cell DNA. The amount of radiation absorbed by a human exposed to far field electromagnetic radiation (EMR) depends on the orientation and size of the person. In the 30-300 MHz range it is possible to excite resonance in the whole or partial body such as the head. It is emphasised ...
1996-01-01
International Nuclear Information System (INIS)
Purpose: To assess the relationship between large intracranial vessel occlusive vasculopathy (vasculopathy) and radiation therapy, and to clarify the clinical efficacy of magnetic resonance (MR) imaging in the diagnosis and screening of the vasculopathy. Methods and Materials: We retrospectively evaluated the medical records and serial MR images for 32 pediatric patients, in whom radiation therapy had been given to fields including the circle of Willis and major cerebral arteries. All children had periodically undergone follow-up neurologic assessment and MR imaging examinations at Kanagawa Children's Medical Center for more than one year after radiation therapy (range 1.3-14 years). Patients who had not remained free of tumor progression up to the time of final evaluation were excluded. Results: Vasculopathy developed in 6 of 32 patients 2-13 years after radiation therapy. Three of ...
1997-05-01
Biogenic iron oxyhydroxide formation at mid-ocean ridge hydrothermal vents: Juan de Fuca Ridge
Energy Technology Data Exchange (ETDEWEB)
Here we examine Fe speciation within Fe-encrusted biofilms formed during 2-month seafloor incubations of sulfide mineral assemblages at the Main Endeavor Segment of the Juan de Fuca Ridge. The biofilms were distributed heterogeneously across the surface of the incubated sulfide and composed primarily of particles with a twisted stalk morphology resembling those produced by some aerobic Fe-oxidizing microorganisms. Our objectives were to determine the form of biofilm-associated Fe, and identify the sulfide minerals associated with microbial growth. We used micro-focused synchrotron-radiation X-ray fluorescence mapping (mu XRF), X-ray absorption spectroscopy (mu EXAFS), and X-ray diffraction (mu XRD) in conjunction with focused ion beam (FIB) sectioning, and highresolution transmission electron microscopy (HRTEM). The chemical and mineralogical composition of an Fe-encrusted biofilm was queried at different spatial scales, and the spatial relationship between primary ...
2008-05-22
Energy Technology Data Exchange (ETDEWEB)
Long-Range Alpha Detector (LRAD) systems are designed to monitor alpha contamination by measuring the number of ions in the air. Alpha particles are a form of ionizing radiation and a typical 5-MeV alpha particle will create about 150,000 ion pairs in air. Field tests at various DOE sites have shown that LRAD Surface Soil Monitors (SSM), Sample Monitors, and Object Monitors are faster and more sensitive than traditional alpha detectors for measuring alpha contamination. This paper discusses the various applications of LRAD technology to low-level radioactive waste management.
1993-12-01
Role of mechanical vibration in preventive maintenance programmes
Energy Technology Data Exchange (ETDEWEB)
Vibration of machinery plays an important role in preventive maintenance programs of machinery. It can be applied in different phases ranging from simple to computerized programs. The advantages of applying machine condition monitoring programs are numerous since vibration measurement and analysis leads to the early detection of component deterioration. The cost, savings and some details of the vibration preventive maintenance program are discussed.
1989-11-01
Nitrogen isotope identification by Bragg-curve spectroscopy
Energy Technology Data Exchange (ETDEWEB)
Projectilelike fragments following the 80 MeV /sup 16/O+/sup 27/Al reaction have been detected using a Bragg-curve spectroscopy ionization chamber (BCS-IC). The atomic number is deduced from the Bragg-peak amplitude. Nitrogen isotopes are clearly resolved using either range or energy loss data. This is the first application of the BCS method for complete ion identification in a heavy-ion-induced reaction.
1984-07-14
Nitrogen isotope identification by Bragg-curve spectroscopy
International Nuclear Information System (INIS)
Projectilelike fragments following the 80 MeV "1"6O+"2"7Al reaction have been detected using a Bragg-curve spectroscopy ionization chamber (BCS-IC). The atomic number is deduced from the Bragg-peak amplitude. Nitrogen isotopes are clearly resolved using either range or energy loss data. This is the first application of the BCS method for complete ion identification in a heavy-ion-induced reaction.
Nanoparticle-assisted chemiluminescence and its applications in analytical chemistry
British Library Electronic Table of Contents (United Kingdom)
This comprehensive, critical review summarizes the use of nanoparticles in enhanced and amplified chemiluminescence detection, illustrated by different reaction strategies, electrogenerated chemiluminescence sensors, immunoassay or hybridization labels and electrogenerated chemiluminescence immunoassay or hybridization sensors. We discuss the analytical applications on the basis of validity, range and sensitivity, and draw some useful conclusions about the most sensitive approach in each type of application.
2010-01-01
Manufacture and characterization of Pb(1-x)Sn(x)Te photoconductors
A general account of the properties, growing technology and annealing of lead-tin-telluride single crystals is given. Photoconductors were made for the 8 to 14 micron. spectral range and responsivity, detectivity and spectral response measurements showed satisfactory results. Improvement in the growing and annealing of the single crystals promise good performance in the near future.
1984-03-01
Bragg curve spectroscopy in a 4? geometry
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4? geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon.
1991-02-01
Bragg curve spectroscopy in a 4. pi. geometry
Energy Technology Data Exchange (ETDEWEB)
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4{pi} geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).
1991-02-01
Bragg curve spectroscopy in a 4#pi# geometry
International Nuclear Information System (INIS)
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4#pi# geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).
Optical Turbulence Measurements and Models for Mount John University Observatory
Site measurements were collected at Mount John University Observatory in 2005 and 2007 using a purpose-built scintillation detection and ranging system. $C_n^2(h)$ profiling indicates a weak layer located at 12 - 14 km above sea level and strong low altitude turbulence extending up to 5 km. During calm weather conditions, an additional layer was detected at 6 - 8 km above sea level. $V(h)$ profiling suggests that tropopause layer velocities are nominally 12 - 30 m/s, and near-ground velocities range between 2 -- 20 m/s, dependent on weather. Little seasonal variation was detected in either $C_n^2(h)$ and $V(h)$ profiles. The average coherence length, $r_0$, was found to be $7 \\pm 1$ cm for the full profile at a wavelength of 589 nm. The average isoplanatic angle, $\\theta_0$, was $1.0 \\pm 0.1$ arcsec. The mean turbulence altitude, $\\bar{h_0}$, was found to be $2.0\\pm0.7$ km ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
This study presents results from Monte Carlo radiation transport calculations aimed at characterizing a novel methodology being developed to detect partial defects in Pressurized Water Reactor (PWR) spent fuel assemblies (SFAs). The methodology uses a combination of measured neutron and gamma fields inside a spent fuel assembly in an in-situ condition where no movement of the fuel assembly is required. Previous studies performed on single isolated assemblies resulted in a unique base signature that would change when some of the fuel in the assembly is replaced with dummy fuel. These studies indicate that this signature is still valid in the in-situ condition enhancing the prospect of building a practical tool, Partial Defect Detector (PDET), which can be used in the field for partial defect detection.
2008-04-28
Authentication of byte sequences
Energy Technology Data Exchange (ETDEWEB)
Algorithms for the authentication of byte sequences are described. The algorithms are designed to authenticate data in the Storage, Retrieval, Analysis, and Display (SRAD) Test Data Archive of the Radiation Effects and Testing Directorate (9100) at Sandia National Laboratories, and may be used in similar situations where authentication of stored data is required. The algorithms use a well-known error detection method called the Cyclic Redundancy Check (CRC). When a byte sequence is authenticated and stored, CRC bytes are generated and attached to the end of the sequence. When the authenticated data is retrieved, the authentication check consists of processing the entire sequence, including the CRC bytes, and checking for a remainder of zero. The error detection properties of the CRC are extensive and result in a reliable authentication of SRAD data.
1991-06-01
Soil gas, soil, and water were assessed for organic and inorganic constituents at the former 19th Street landfill at Fort Gordon, Georgia, from February to September 2010. Passive soil-gas samplers were analyzed to evaluate organic constituents in the hyporheic zone and flood plain of a creek and soil gas within the estimated boundaries of the former landfill. Soil and water samples were analyzed to evaluate inorganic constituents in soil samples, and organic and inorganic constituents in the surface water of a creek adjacent to the landfill, respectively. This assessment was conducted to provide environmental constituent data to Fort Gordon pursuant to requirements of the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. The passive soil-gas samplers deployed in the water-saturated hyporheic zone and flood plain of the creek adjacent to the former landfill indicated the presence of total petroleum hydrocarbon (TPH) and octane above method ...
2011-01-01
Use of radiosensitivity to identify irradiated fresh poultry products
International Nuclear Information System (INIS)
Microbiological comparison between irradiated and non-irradiated foodstuff has been studied for a long time as a way to detect whether a foodstuff has been irradiated or not. Generally, the proposed methods are based on the fact that ionization select species of bacteria which are recognized to be radioresistant. So reduction or elimination of known radiation sensitive microbes from the normal endogenous microflora could give an indication that the foodstuff has been irradiated, predominance of known radioresistant bacteria should be another indication. In the present work, we try to develop a test based on the radiosensitivity of the bacteria independently of their place. These first experiments show that the determination of radiosensitivity of strains isolated from a product or even of global radioresistance of mesophilic microflora could indicate if this product has been previously submitted to ionizing radiations. (4 ...
1990-02-14
International Nuclear Information System (INIS)
A high-density gas jet supersonic nozzle is reported in this paper. The jitter and actuation time of the nozzle is determined by the pin discharge and laser spark radiation respectively. The jitter time of the nozzle is within 10 ?s with the backing pressure as high as 25 bar. With a nanosecond laser pulse focused on the gas jet about 1 mm below the nozzle, the actuation time is calculated to be about 15 ms by detecting the laser produced spark radiation, which reveals the existence of the gas jet and the relative gas density evolving with time. Consequently the gas density is estimated to be well above 1019 cm-3, compared with theoretical simulations from the nozzle parameters.
2006-07-01
Superconducting strip detectors as position sensitive particle detectors
Energy Technology Data Exchange (ETDEWEB)
The feasibility of using of current-biased superconducting strips for radiation detection is investigated. Narrow Ta strips are exposed to 5.5 MeV [alpha]-particle radiation and the rise-time of the induced voltage pulses is measured as function of temperature and bias current. The rise-time of the voltage signal strongly depends on the site on the strip which is hit by the [alpha]-particle. In order to determine the spatial resolution of a superconducting strip detector, position-sensitive measurements were performed. The maximum lateral resolution estimated so far is 25[mu]m in a 7[mu]m wide, 340 nm thick and 0.6 mm long Ta-strip. (orig.)
1994-02-01
Point defects in dilute nitride III-N-As and III-N-P
International Nuclear Information System (INIS)
We provide a brief review of our recent results from optically detected magnetic resonance studies of grown-in non-radiative defects in two most important dilute nitride systems-Ga(In)NAs grown on GaAs substrates and Ga(Al,In)NP grown on Si and GaP substrates. These results have led to the identification of defect complexes in the alloys, involving intrinsic defects such as As_G_a antisites and Ga_i self-interstitials. They have also shed light on formation mechanisms of the defects and on their role in non-radiative carrier recombination that is harmful to the performance of potential optoelectronic and photonic devices based on these dilute nitrides.
2006-04-01
Gamma-rays and neutrinos from the pulsar wind nebulae
Energy Technology Data Exchange (ETDEWEB)
We construct the time-dependent radiation model for the pulsar wind nebulae (PWNe), assuming that leptons are accelerated in resonant scattering with heavy nuclei, which are injected into the nebula by the pulsar. The equilibrium spectra of these particles inside the nebula are calculated taking into account their radiation and adiabatic energy losses. The spectra of {gamma}-rays produced by these particles are compared with the observations of the PWNe emitting TeV {gamma}-rays and predictions are made for the expected {gamma}-ray fluxes from other PWNe. Expected neutrino fluxes and neutrino event rates in a 1 km{sup 2} neutrino detector from these nebulae are also calculated. It is concluded that only the Crab Nebula can produce a detectable neutrino event rate in the 1 km{sup 2} neutrino detector. Other PWNe can emit TeV {gamma}-rays on the level of a few percent of that observed from the Crab Nebula.
2005-08-01
Simple and low cost biosensor based on screen-printed electrode for sensitive detection of some alkylphenols was developed, by entrapment of HRP in a nanocomposite gel based on single-walled carbon nanotubes (SWCNTs) and 1-butyl-3-methylimidazolium hexafluorophosphate ([BMIM][PF(6)]) ionic liquid. Raman and FTIR spectroscopy, CV and EIS studies demonstrate the interaction between SWCNTs and ionic liquid. The nanocomposite gel, SWCNT-[BMIM][PF(6)] provides to the modified sensor a considerable enhanced electrocatalytic activity toward hydrogen peroxide reduction. The HRP based biosensor exhibits high sensitivity and good stability, allowing a detection of the alkylphenols at an applied potential of -0.2V vs. Ag/AgCl, in linear range from 5.5 to 97.7?M for 4-t-octylphenol and respectively, between 5.5 and 140?M for 4-n-nonylphenol, with a response time of about 5s. The detection limit was 1.1?M for ...
2011-07-19
Binary compact object coalescence rates: The role of elliptical galaxies
We estimate binary compact object merger detection rates for LIGO, including the binaries formed in ellipticals long ago. Specifically, we convolve hundreds of model realizations of elliptical- and spiral-galaxy population syntheses with a model for elliptical- and spiral-galaxy star formation history as a function of redshift. Our results favor local merger rate densities of 4\\times 10^{-3} {Mpc}^{-3}{Myr}^{-1} for binary black holes (BH), 3\\times 10^{-2} {Mpc}^{-3}{Myr}^{-1} for binary neutron stars (NS), and 10^{-2} {Mpc}^{-3}{Myr}^{-1} for BH-NS binaries. Mergers in elliptical galaxies are a significant fraction of our total estimate for BH-BH and BH-NS detection rates; NS-NS detection rates are dominated by the contribution from spiral galaxies. Using only models that reproduce current observations of Galactic NS-NS binaries, we find slightly higher rates for NS-NS and largely similar ranges for ...
2009-01-01
The cosmic-ray antiproton spectrum between 0. 1 and 1. 5 GeV kinetic energy
Energy Technology Data Exchange (ETDEWEB)
In the summer of 1980, a balloon-borne cosmic ray experiment reported the detection of 14 low energy antiprotons during an 18 hour flight. This measurement represented an antiproton intensity two orders of magnitude greater than that predicted by conventional theories. This surprising result triggered a flurry of papers theorizing the origin of these particles, including the prediction of domains of primary antimatter, and evidence for supersymmetric particle annihilation. Not until the summer of 1987 was a follow up experiment (PBAR) performed. The PBAR detector has both better resolution and a larger dynamic range in energy than the previous detector. It measured the energy spectrum of antiprotons in the 0.1-1.5 GeV kinetic energy range. The present work describes the instrument, the experiment, and the results. Our analysis of the PBAR data reveals no antiprotons in the energy range of 0.13-0.64 GeV ...
1988-01-01
Viscosity changes in hyaluronic acid: Irradiation and rheological studies
Energy Technology Data Exchange (ETDEWEB)
Hyaluronic acid (HA) is a significant component of the extracellular matrix (ECM), particular interest being shown herein in synovial fluid. The present study aims to investigate the degrading effects of X-ray radiation on HA at radiotherapy doses. Measurements of viscosity and shear stresses on HA solutions have been made at different shear rates using various types of viscometer for different concentrations in the range 0.01-1% w/v of HA. The HA has been subjected to doses of 6 MV photon radiation ranging from 0 to 20 Gy, the major emphasis being on doses below 5 Gy. It is found that there is a dose-dependent relationship between viscosity and shear rate, viscosity reducing with radiation dose, this being related to polymer scissions via the action of radiation-induced free radicals. The dependency appears to become weaker at higher concentrations, possibly ...
2010-04-15
Energy Technology Data Exchange (ETDEWEB)
The PAMELA (a Payload for Antimatter-Matter Exploration and Light-nuclei Astrophysics) space mission has been launched on-board the Resurs-DK1 satellite on June 15{sup th} 2006 from the Baikonur cosmodrome, in Kazakhstan. PAMELA is a particle spectrometer designed to study charged particles in the cosmic radiation with special focus on the investigation of the nature of dark matter, by mean of the measure of the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved.
2009-03-15
Mechanism of radiation induced carcinogenesis: does a threshold exist?
International Nuclear Information System (INIS)
Epidemiological studies will not solve the shape of the dose effect curve for stochastic effects in the low dose range. Unicellular processes are necessary for the primary processes so that no threshold dose exists. This is evident for somatic and genetic mutations. Not clearly solved is this question for the complex carcinogenesis. These processes develop with manifold interacting molecular and cellular steps. (orig.).
1996-10-23
Energy Technology Data Exchange (ETDEWEB)
Heat transfer has emerged as a leading-edge technology supporting the rapid pace of developments in science and engineering ranging from energy production to electronic cooling. Subjects covered at the 6th UK National Conference on heat transfer held at Edinburgh from 15-16 September 1999 include: convection; boiling and evaporation; condensation; numerical techniques; heat exchangers; radiation and combustion; conduction; two-phase flow and heat transfer augmentation. Fifteen of the papers are abstracted here.
1999-07-01
Electronic structure of the Ru(0001) surface
Energy Technology Data Exchange (ETDEWEB)
This paper deals with the electronic structure of ruthenium. Synchrotron radiation in the range from 15 to 45 eV and angle-resolved ultraviolet photoemission are used to map the energies of the electronic states. The Fermi surface of Ru is determined using angle-resolved ultraviolet photoemission spectroscopy. The experimental results are compared with calculated photoemission spectra obtained within the framework of the one-step model of photoemission. (author)
2000-03-13
Electromagnetic effects in relativistic electron beam plasma interactions
Energy Technology Data Exchange (ETDEWEB)
Electromagnetic effects excited by intense relativistic electron beams in plasmas are investigated using a two-dimensional particle code. The simulations with dense beams show large magnetic fields excited by the Weibel instability as well as sizeable electromagnetic radiation over a significant range of frequencies. The possible relevance of beam plasma instabilities to the laser acceleration of particles is briefly discussed. 6 refs., 4 figs.
1985-02-13
International Nuclear Information System (INIS)
The development of a flat response small size, real time neutron dosimeter and ratemeter for the energy range of about 1 eV to 14 MeV is presented. This dosimeter is adequate for measuring neutron dose equivalents of 3 mRem up to 100 Rem and dose rates of 300 mRem/h to 50 Rem/h or more. The dosimeter consists of four Si surface barrier detectors. _1_0B radiators are placed in front of three of the detectors and a polyethylene radiator is placed in front of the fourth one. The _1_0B pellets are used for dose equivalent measurements in the energy range 1 eV to proportional1 MeV. The polyethylene radiator, made in two parts having thicknesses of 10 and 100 mg/cm_2 in an area ratio of 8 to 1, flattens the response to +-40% in the energy range 1-14 MeV. The signal-to-background ratio for different Si surface barrier detectors and for _1_0B polyethylene ...
1983-06-01
International Nuclear Information System (INIS)
Seven types of shellfish were irradiated by gamma ray at doses of 0, 3 and 6 kGy. Pulse photo-stimulated luminescence (PPSL) and thermoluminescence (TL) methods were employed to detect the radiation treatment. The screening of irradiation was carried out by the PPSL method followed by identification using the TL technique. Most of the irradiated shellfish were screened out correctly and only a few showed photon counts a bit higher than the lower threshold value by much lower than the upper threshold value. The TL method was employed using minerals isolated from all the control and irradiated shellfish samples by density gradient treatment. Three parameters, integrated intensities of first glow curves (TL1), ratios of first to that of second glow curves (TL1/TL2), and the shapes of maxima of first glow curves, were utilized for the identification of gamma ray treatment of shellfish. (author)
International Nuclear Information System (INIS)
Full text: An adaptive response is a decreased biological effect induced by a priming radiation dose given prior to a challenge dose. Adaptive responses contradict the linear-nothreshold model of risk estimation. The pKZ1 mouse chromosomal inversion assay is an extremely sensitive assay for studying the mutagenic effect of low dose radiation. A non-linear dose response for chromosomal inversion has been observed in pKZ1 spleen and prostate after a single whole body irradiation with doses between 1?Gy and 10mGy. Doses between 5-10?Gy resulted in an induction in inversions and doses between 1-10mGy resulted in a reduction below endogenous inversion frequency. These results suggest that doses in the 1-10 mGy range cause host responses which overcompensate by not only preventing inversions that would normally occur as a result of the low doses of radiation but also by preventing some of the endogenous ...
2006-04-01
Retrospective individual dosimetry using luminescence and EPR after radiation accidents
International Nuclear Information System (INIS)
In areas where radiation dose monitoring has not been performed, it is essential to use material available in the environment be able to rapidly assess doses to individuals for immediate emergency medical care or for general estimation of the radiological consequences. It was shown that certain types of telephone cards containing microchips have the potential to be used as individual radiation dosimeters in emergency situations to detect doses over 250 mGy by luminescence measurements. In order to understand the dosimetric properties of chip cards, the components obtained from INFINIEON Company at various stages of production were used for luminescence measurements. It is found that the protecting layer used above the chips so called 'globe top' is the main source of radiation induced signal in chip cards. The globe top produced by INFINIEON at that stage is found to contain SiO2 and Epoxy. In order to ...
Radiation-induced reduction of ditetrazolium salt in aqueous solutions
Energy Technology Data Exchange (ETDEWEB)
Color formation in aqueous solutions of the ditetrazolium salt blue tetrazolium (BT{sup 2+}) in the absence or presence of oxygen is a complex radiation chemical reaction. The final stable product is the poorly soluble diformazan violet to blue pigment having a broad spectral absorption band ({lambda}{sub max}=552 nm). The reaction of BT{sup 2+} with the hydrated electron proceeds by rapid reduction of BT{sup 2+} followed by protonation at the nitrogen closest to the unsubstituted phenyl group, via the two intermediate tetrazolinyl radicals shared by the ditetrazole ring nitrogens. The effect of solution pH, N{sub 2}O saturation, and the presence of the reducing agent dextrose are examined. The system serves as a radiochromic sensor and a dosimeter of ionizing radiations. Solutions of 5 mmol l{sup -1} BT{sup 2+} at pH 7.3 serve as dosimeters over an absorbed-dose range of approximately 0.2-6 kGy (dearated, with a ...
2002-04-01
Radiation therapy for Ewing's sarcoma: Results from Memorial Sloan-Kettering in the modern era
International Nuclear Information System (INIS)
Purpose: To evaluate the outcomes of patients with Ewing's sarcoma family of tumors (ESFT) treated with modern radiotherapy techniques with MRI along with optimal chemotherapy. Methods and Materials: The records of all 60 patients with ESFT who received radiation to the primary site between 1990 and 2004 were reviewed. All patients received chemotherapy, including vincristine, doxorubicin, cyclophosphamide, ifosfamide, and etoposide. Radiation was used as the sole modality for local control in 31 patients and was given either before (n = 3) or after surgical resection (n = 26) in the remainder. All patients had MRI and CT scan-based treatment planning, and 43% received intensity-modulated radiation therapy. Radiation doses ranged from 30 Gy to 60 Gy (median, 51 Gy), and 35% received hyperfractionated radiotherapy. Results: Median age was 16 years (range, 2-40 ...
2006-02-01
Energy Technology Data Exchange (ETDEWEB)
Doubly-excited 2s{sup -1}2p{sup -1}3pnp autoionizing resonance series of Ne atom as well as autoionizing resonances in the 2s region of Na and Mg atoms have been studied with monochromatized synchrotron radiation. Use of charge-separated photoion-yield method allowed us to detect these weak resonances in a clarified way in the yield curves of doubly-charged ions. The observed resonance states have been interpreted with the help of MCDF calculations, and the decay processes of these resonance states are discussed briefly.
2007-03-01
International Nuclear Information System (INIS)
Doubly-excited 2s-12p-13pnp autoionizing resonance series of Ne atom as well as autoionizing resonances in the 2s region of Na and Mg atoms have been studied with monochromatized synchrotron radiation. Use of charge-separated photoion-yield method allowed us to detect these weak resonances in a clarified way in the yield curves of doubly-charged ions. The observed resonance states have been interpreted with the help of MCDF calculations, and the decay processes of these resonance states are discussed briefly.
2007-03-01
Nuclear borehole logging using lithium detector assemblies
International Nuclear Information System (INIS)
A method and apparatus for nuclear borehole logging, and in particular, neutron porosity logging, uses a neutron source, and a pair of spaced lithium detectors, preferably Li"6I crystal or Li"6 doped glass, to detect neutrons emitted from a borehole formation being logged. The spectrum developed by the lithium detectors is processed to remove the gamma ray background radiation and the hydrogen absorption peak, thus allowing a more accurate neutron count. A Gaussian curve is fitted to the neutron peak of the spectrum, the curve eliminating the hydrogen absorption peak. The area under this Gaussian curve represents the neutron count. (author).
1991-11-01
Multielement analysis of air samples
International Nuclear Information System (INIS)
Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A "2"3"8Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed. (author).
1981-01-01
International Nuclear Information System (INIS)
With a computerized curve fitting method the trapping parameters of TLD-100 chips were calculated after #alpha#-, #beta#- and #gamma#-irradiation. The absorption of radiation produces an additional glow peak at 250 deg C, and the dominant one arises at 280 deg C. After the analysis of the glow curves only a little LET-dependence of the trap depths and that of the half widths was detected. The charge densities after irradiation before heating of the taps responsible for the high temperature glow peaks (T>240 deg C) show a LET-dependence. (author).
1985-10-22
Gamma Radiation Detectors of the TA-55 Waste Line Monitoring System
Energy Technology Data Exchange (ETDEWEB)
This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.
1999-06-01
Energy Technology Data Exchange (ETDEWEB)
Changes in the phosphate metabolism of the transplanted SCCVII (squamous cell carcinoma VII) tumor were studied before and after irradiation using in vivo [sup 31]P-magnetic resonance spectroscopy (MRS). Phosphocreatine (PCr), [gamma]-, [alpha]-, [beta]-ATP, inorganic phosphate (Pi), phosphomonoester (PME), and phosphodiester (PDE) were detected in [sup 31]P-MR spectra of tumor tissues. The curve fitting method was employed for calculating each peak of [sup 31]P-MR spectra (PCr, [beta]-ATP, Pi, PME, PDE). The values of PCr, PCr/Pi, [beta]-ATP/Pi and pH decreased in proportion to the growth of tumor, whereas that of Pi, PME and PDE increased. But the changes of [beta]-ATP were minimal in degree. Based on the fact that the ratio of PCr/Pi highly correlated with tumor volume and showed the most remarkable change among various parameters, it might be the useful index for the tumor growth. Because the phospholipid metabolite PME was detected in the ...
1992-03-01
Energy Technology Data Exchange (ETDEWEB)
Marketing of minimally processed vegetables (MPV) are gaining impetus due to its convenience, freshness and apparent health effect. However, minimal processing does not reduce pathogenic microorganisms to safe levels. Food irradiation is used to extend the shelf life and to inactivate food-borne pathogens. In combination with minimal processing it could improve safety and quality of MPV. A microbiological screening method based on the use of direct epifluorescent filter technique (DEFT) and aerobic plate count (APC) has been established for the detection of irradiated foodstuffs. The aim of this study was to evaluate the applicability of this technique in detecting MPV irradiation. Samples from retail markets were irradiated with 0.5 and 1.0 kGy using a {sup 60}Co facility. In general, with a dose increment, DEFT counts remained similar independent of the irradiation while APC counts decreased gradually. The difference of the two counts ...
2009-07-15
A superconducting solenoidal spectrometer for a balloon-borne experiment
Energy Technology Data Exchange (ETDEWEB)
The BESS detector is a new type of balloon-borne spectrometer which utilizes various technologies recently developed for collider experiments. The principal scientific objectives include a measurement of cosmic-ray antiproton spectrum, search for anti-nuclei in cosmic radiation, and precise measurements of cosmic-ray primaries. A thin superconducting solenoidal coil produces a uniform magnetic field of 1 T. Cylindrical drift chambers are located inside and outside the coil and perform continuous tracking. The momentum resolution is 0.5% at 1 GeV/c. i.e., the maximum detectable rigidity is 200 GV. Scintillation counter hodoscopes, placed above and below the solenoid, provide timing and dE/dx measurements and trigger generation. The timing resolution is 80 ps/counter. This cylindrical configuration achieves a large geometrical acceptance of 0.35 m{sup 2} sr which is essential to detect rare cosmic-ray particles. In order to ...
2000-03-21
Boron-Lined Multichamber and Conventional Neutron Proportional Counter Tests
Energy Technology Data Exchange (ETDEWEB)
Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. These technologies are: 1) Boron ...
2010-09-07
Local Radiation MHD Instabilities in Magnetically Stratified Media
We study local radiation magnetohydrodynamic instabilities in static, optically thick, vertically stratified media with constant flux mean opacity. We include the effects of vertical gradients in a horizontal background magnetic field. Assuming rapid radiative diffusion, we use the zero gas pressure limit as an entry point for investigating the coupling between the photon bubble instability and the Parker instability. Apart from factors that depend on wavenumber orientation, the Parker instability exists for wavelengths longer than a characteristic wavelength lambda_{tran}, while photon bubbles exist for wavelengths shorter than lambda_{tran}. The growth rate in the Parker regime is independent of the orientation of the horizontal component of the wavenumber when radiative diffusion is rapid, but the range of Parker-like wavenumbers is extended if there exists strong horizontal shear between field lines ...
2011-01-01
Early forecast of radiation-hazardous solar cosmic ray fluxes on the neutron monitors data
The system of the early forecast of radiation hazardous fluxes of solar cosmic rays in space on the basis of the real time neutron monitors data obtained by the NMDB (Neutron Monitor Data Base) network is created. The forecast system is based on a short cut technique of definition of a spectrum of solar protons from the data of the limited number of neutron monitor stations and with a simplified procedure of accounts. It is shown that the results of computations of solar proton spectra with the short-cut technique little differ from spectra obtained with a complete technique at energies less than 5 GeV. Thus the good agreement between derived from the neutron monitor data intensities of solar protons in an energy range of hundreds MeV with the data of direct measurements of solar protons at GOES-11 spacecraft is observed. The maximum of increase on neutron monitors outstrips on several hours (2-10) an appropriate maximum of ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
It has recently been found that many buildings in Taiwan were constructed with radioactively contaminated rebar, which raised great concern among the residents as well as governmental officials. In order to investigate the possible cytogenetic damage to the residents of contaminated buildings, a G-banding method was carried out on the lymphocytes of 30 radiation-exposed individuals from four families and one office building, as well as 15 control individuals from laboratory personnel. The estimated cumulative radiation doses for the exposed people range from 19.63 to 280.50 mSv. Altogether, 13 females and 17 males belonging to the radiation-exposed group, and 7 females and 8 males in the control group, were included in this study. With the exception of one sample, at least 500 metaphase spreads were scored and analyzed for each individual. All the recognizable structural aberrations of chromosomes or ...
1997-07-03
International Nuclear Information System (INIS)
It has recently been found that many buildings in Taiwan were constructed with radioactively contaminated rebar, which raised great concern among the residents as well as governmental officials. In order to investigate the possible cytogenetic damage to the residents of contaminated buildings, a G-banding method was carried out on the lymphocytes of 30 radiation-exposed individuals from four families and one office building, as well as 15 control individuals from laboratory personnel. The estimated cumulative radiation doses for the exposed people range from 19.63 to 280.50 mSv. Altogether, 13 females and 17 males belonging to the radiation-exposed group, and 7 females and 8 males in the control group, were included in this study. With the exception of one sample, at least 500 metaphase spreads were scored and analyzed for each individual. All the recognizable structural aberrations of chromosomes or ...
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study is to identify the radiative heat transfer augmentation by a coaxial cylinder introduced in the infinite cylindrical pipe enclosing a participating gas. The gas is either a mixture of water vapor and carbon dioxide or gray. The gas is assumed to be homogeneous at a constant temperature, and has a refractive index of unity. All of the surfaces are opaque and gray, diffusely emitting and reflecting at a constant temperature. The effect of system diameter, diameter ratio, wall emittances, gas and surface temperatures, mixture component on heat transfer augmentation are studied by using the zone method with participating gas radiative properties evaluated from the weighted sum of gray gases model. From the radiative equilibrium condition, the installed wall temperature is formulated and calculated by the iteration method. If the medium is a gray gas, the augmentation observed are negligible. For the ...
1992-10-01
Molecular events involved in ionizing radiation induced skin carcinogenesis
International Nuclear Information System (INIS)
The process of mouse skin tumor formation is subdivided into three operational stages. These stages include initiation, promotion and progression. Ionizing radiation has been found to be a weak initiating agent in the production of malignant squamous cell carcinomas, a complete carcinogen and an agent effective in causing tumor progression. Four skin tumor histologies have been seen with ionizing radiation: benign papillomas, squamous (SCC) and basal (BCC) cell carcinomas and fibrosarcomas. Distinct non-ras transforming genes have been detected in radiation initiated SCCs. A benign papilloma cell line (308) was used as a model system to study ionizing radiation induced progression. A variant 308 cell line (308 10 Gy 5) derived by irradiation of the parental 308 cell has been characterized. The 308 10 Gy 5 cells unlike the parental 308 cells from malignant tumors in athymic nude mice ...
Energy Technology Data Exchange (ETDEWEB)
Investigated here were the effects of microwave (MW) radiation (2450-MHz, continuous-wave, mean specific absorption rate of 103.5 + or - 4.2 W/kg) and convention heating on the nonphosphorylating oxidative metabolism of human peripheral mononuclear leukocytes (96% lymphocytes, 4% monocytes) at 37 C. Metabolic activity, determined by chemiluminescence (CL) of cells challenged with luminol (5-aminO-2, 3-dihydro-1, 4-phthalazinedione) linked to bovine serum albumin, was detected with a brightness photomer. A significant stimulation after after MW exposure (p < 0.005) over total CL of matched 37 C-incubator controls was observed. A similar degree of stimulation, compared to incubator controls, was also detected after sham treatment. No significant difference existed between changes in total CL or stimulation indices of the MW and sham-exposed groups. Exposure to MW radiation, under normothermic (37 + or ...
1986-01-01
The Galactic Exoplanet Survey Telescope (GEST)
The Galactic Exoplanet Survey Telescope (GEST) will observe a 2 square degree field in the Galactic bulge to search for extra-solar planets using a gravitational lensing technique. This gravitational lensing technique is the only method employing currently available technology that can detect Earth-mass planets at high signal-to-noise, and can measure the frequency of terrestrial planets as a function of Galactic position. GEST's sensitivity extends down to the mass of Mars, and it can detect hundreds of terrestrial planets with semi-major axes ranging from 0.7 AU to infinity. GEST will be the first truly comprehensive survey of the Galaxy for planets like those in our own Solar System.
2002-01-01
Study of point defect detectors in Si
International Nuclear Information System (INIS)
The importance of point defects in semiconductor and function materials has been studied in detail, but effective means for detecting point defects has not been available for a long time. The end of range defects in Si, produced by 140 keV Ge"+ implantation, were investigated as detectors for measuring the interstitial concentration created by 42 keV B"+ implantation. The concentration of interstitial resulting from the B"+ implantation and the behavior of the interstitial flux under different annealing condition were given. The enhanced diffusion in the boron doped EPI marker, resulting from mobile non-equilibrium interstitials was demonstrated to be transient. Interstitial fluxes arising from processing can be detected by transient enhanced diffusion (TED) of doped marker layers as well
1999-05-01
Antibodies to Rickettsia rickettsii were detected by indirect immunofluorescence in sera from 149 of 467 dogs (32%) examined from 4 military installations located in Kentucky, North Carolina, Pennsylvania, and Virginia. The prevalence at individual installations ranged from 4.3% at Fort Knox, Ky, to 63.4% at Fort Bragg, NC. Most of the seropositive dogs were in the working and sporting groups of dogs. The difference in antibody prevalence between sexes was not significant. Serologic responses were related to R rickettsii infection, although antibodies to R montana also were detected in a few of the sera. Comparison of serodiagnostic methods indicated that the indirect fluorescent antibody test was more sensitive than was the indirect hemagglutination test for obtaining survey data on the prevalence of Rocky Mountain spotted fever in the area. PMID:6808878
1982-08-01
Interaction of constituents of the Yb-Pd-Si system in the range of zero to 40 at.% Yb
International Nuclear Information System (INIS)
Interaction of Yb-Pd-Si system components is studied, isothermal cross section of this system state diagram at 870 K is constructed. Five new ternary silicides are detected in the system: YbPd_5Si_3, Yb_3Pd_2_0Si_6, YbPd_2Si, YbPd_0_,_6_7Si_1_,_3_3, YbPdSi; the existence of one more -YbPd_2Si_2, earlier known, is confirmed. Crystal structure for all the compounds detected is determined and examined. Data on the materials magnetic properties are obtained. It is assumed that YbPd_2Si, YbPd_2Si_2 and YbPdSi compounds appear to be the Condo-systems. 10 refs., 3 figs., 3 tabs.
British Library Electronic Table of Contents (United Kingdom)
Surveys were carried out in 2006 and 2007 in Umbria (central Italy) to evaluate the presence of mycotoxigenic fungi and mycotoxins in maize grain sampled at harvest. Fusarium spp., were the most abundant species detected in maize kernels, followed by Aspergillus species of sections Flavi and Nigri and by Penicillium spp. Among Fusarium species, F. verticillioides was the most prevalent species, as detected by PCR directly on the kernels and on the fungi isolated from the kernels, followed by F. proliferatum and F. subglutinans. Fumonisins were the predominant mycotoxins with values, on average, of 4.3 and 5.7mgkg-1, in 2006 and 2007, respectively, with a maximum of 76.3mgkg-1 in the second year. Deoxynivalenol ranged from 0.2 to 3.98mgkg-1 in 2006 (average 1.04mgkg-1) and from undetectable...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
A data analysis based on an artificial neural network classifier is proposed to identify cosmic ray antiprotons detected with the CAPRICE silicon-tungsten imaging calorimeter against electron background in the energy range 1.2-4.0 GeV. A set of new physical variables, describing the events inside the calorimeter on the base of their different patterns, are introduced in order to discriminate between hadronic and electromagnetic showers. The ability of the artificial neural network classifier to perform a careful multidimensional analysis gives the possibility to identify antiprotons with an electron rejection 408{+-}85 (stat) at 95.0{+-}0.2 (stat)% of signal detection efficiency. The high accuracy achieved by this method improves substantially the efficiency in the evaluation of the cosmic ray antiproton spectrum. (orig.).
1996-11-01
Energy Technology Data Exchange (ETDEWEB)
The reaction mechanism underlying the 44 MeV/u {sup 40}Ar projectile break-up process has been studied on different targets, by measuring the coincidences between light particles or intermediate mass fragments detected in a large angular range, and projectile fragments or light charged particles. While the experimental data relative to projectile-like fragments (PLF) with charge close to the one of the projectile can be interpreted in the framework of a three source analysis, the anomalous light fragment production with Z {<=} 10 rather suggests `fission` as one of the possible decay mode of the highly excited projectile or PLF. It is also observed that a great amount of the forward detected light charged particles are correlated, and due to the break-up or decay of light excited ions. (author). 9 refs.
1996-09-01
International Nuclear Information System (INIS)
The effect of the #+-# 0.75 T external magnetic field on the K_#alpha#_1, K_#alpha#_2, K_#beta#_'_1 and K_#beta#_'_2 x-ray production cross sections and radiative vacancy transfer probabilities from K-shell to L2 and L3 subshells and M-shell for ferromagnetic Nd, Gd and Dy and paramagnetic Eu and Ho have been investigated, using the 59.5 keV incident photons. K-shell fluorescence yields and K x-ray intensity ratios for these elements have been determined in the external magnetic field also. The K x-rays from different targets were detected using a high-resolution Si(Li) semiconductor detector. For B = 0, the present experimental results were compared with the experimental and theoretical data in the literature. The results show that K-shell fluorescence parameters such as photoionization cross section, fluorescence yield, radiation rates, vacancy transfer probabilities and spectral linewidth can change owing to the applied ...
2006-06-19
Energy Technology Data Exchange (ETDEWEB)
We report a patient who developed occlusion of the intracranial major arteries induced by radiation therapy for craniopharyngioma. The patient, a 9-year-old boy, presented with deterioration of vision, nausea and vomiting. He underwent a right ventriculo-peritoneal shunt operation, and the tumor was partially removed. Postoperatively, he received focal radiation therapy with total of 60 Gy. Preoperative cerebral angiography, cerebral vessels had no sigh of occlusive lesion or stenosis. One year after irradiation, he started to have repeated cerebral ischemic attacks. But no regrowth of the tumor was detected on CT scans. Two years and 8 months after irradiation, he suddenly had right hemiparesis. Cerebral angiography revealed severe stenosis of the right anterior cerebral artery (precommunicating segment), middle cerebral artery (horizontal portion) and terminal portion of the right carotid artery. Left carotid angiography ...
1994-10-01
International Nuclear Information System (INIS)
We report a patient who developed occlusion of the intracranial major arteries induced by radiation therapy for craniopharyngioma. The patient, a 9-year-old boy, presented with deterioration of vision, nausea and vomiting. He underwent a right ventriculo-peritoneal shunt operation, and the tumor was partially removed. Postoperatively, he received focal radiation therapy with total of 60 Gy. Preoperative cerebral angiography, cerebral vessels had no sigh of occlusive lesion or stenosis. One year after irradiation, he started to have repeated cerebral ischemic attacks. But no regrowth of the tumor was detected on CT scans. Two years and 8 months after irradiation, he suddenly had right hemiparesis. Cerebral angiography revealed severe stenosis of the right anterior cerebral artery (precommunicating segment), middle cerebral artery (horizontal portion) and terminal portion of the right carotid artery. Left carotid angiography ...
1994-01-01
International Nuclear Information System (INIS)
The radiographic appearance of Ewing's sarcoma was studied retrospectively in 22 patients who survived 5 years or longer after diagnosis and treatment. Expected changes from treatment, including regression of the extraosseous soft tissue mass, periostitis, and reconstitution of the cortex, occurred in all patients. Local recurrence occurred in one patient 10 years after complete remission whereas secondary osteosarcoma occurred more than 5 years after complete remission in two other cases. Both recurrent and secondary tumors presented as new lytic foci at the site of the original primary lesion. Lytic changes from radiation (radiation osteitis) may develop more than 2 years after treatment and in this sample; such findings were widely distributed in the radiation port. The authors conclude that bone remodeling and postradiation changes occur slowly over 2 years after treatment, and that any localized lysis at the primary ...
Energy Technology Data Exchange (ETDEWEB)
The research carried out in Canada in the design of containers for the disposal of radioactive waste has focussed on spent nuclear fuel, even though the quantities of other currently stored radioactive wastes are substantially greater. Research carried out at the Royal Military College of Canada on the effects of mixed fields of radiation on high polymer adhesives and composite materials has shown that some polymers are quite resistant to radiation and could well serve in the fabrication of radioactive waste disposal containers. The purpose of this research was to determine if thermoplastic polymers could be used as superior materials to replace metals in the application of low and intermediate level radioactive waste disposal containers. Polymers have the advantage that they do not corrode like metals. The experimental methods, used in this research, focused on the effects of radiation on the properties of the materials. ...
2001-07-01
International Nuclear Information System (INIS)
... organizations irradiation radiation doses radiation effects RADIATIONS.
1982-01-01
Radiation technology of wood-plastic composite materials
International Nuclear Information System (INIS)
... radiation effects RADIATIONS. WOOD-PLASTIC COMPOSITES.
1981-10-02
Radiation chloration sulfochloration and sulfooxidation of organic compounds
International Nuclear Information System (INIS)
... halogenation ionizing radiations kinetics radiations reaction kinetics
Energy Technology Data Exchange (ETDEWEB)
The object and the purpose of the present work was to develop, to assemble and to start running a new TOF (time of flight) mass spectrometer for imaging SNMS analytic which is optimized for the analysis of highly molecular secondary ions. The most important purpose was the characterization of the TOF mass spectrometer. The obtained mass spectra of indium, tantalum and silver clusters reflect the excellent properties of the TOF mass spectrometer for the detection of large clusters with good detection efficiency up to masses of 16000 amu. The possibility of the deflection of selected saturated atom and cluster peaks serves for further improvement of the detection efficiency for large molecules. The accessible mass resolution was determined to be of the order of m/{delta}m=1000 in the high mass region. Numerous measurements were carried out to characterize the useful yield of this spectrometer. For a best possible adaptation ...
2006-12-21
Energy Technology Data Exchange (ETDEWEB)
In the present work temperature dependences of heat capacity of carbosilane dendrimers with butyl terminal groups of the third and the fourth generations as well as of the fifth and the sixth generations have been determined first in the range from 6 to 340K and between 6 and 600K, respectively, by precision adiabatic vacuum and dynamic calorimetry. In the above temperature ranges the physical transformations have been detected and their thermodynamic characteristics have been estimated and analyzed. The experimental data were used to calculate standard thermodynamic functions, namely the heat capacity C{sub p}{sup o}(T), enthalpy H{sup o}(T)-H{sup o}(0), entropy S{sup o}(T)-S{sup o}(0) and Gibbs function G{sup o}(T)-H{sup o}(T), for the range from T->0 to (340-600)K. Linear dependences of changing the corresponding thermodynamic functions of the dendrimers on their molecular weight and the ...
2006-01-15
Effect of elevated temperatures on the performance of an InP cell illuminated by a selective emitter
Energy Technology Data Exchange (ETDEWEB)
The thermophotovoltaic (TPV) option was not selected for further deep space mission technology development in NASA for several reasons. Chief among them was the large radiator required to keep the photovoltaic cells at a sufficiently low operating temperature. This led to significant integration problems with the spacecraft and limited sensor view angles. It is clear that the issue of cell temperature is crucial for space applications because of radiator size and system impact. Many efforts have focused on matching cell band gap to appropriate emitters in the 1 to 2 {mu}m range, resulting in band gaps in the 0.5 to 0.8 eV range. However, low band gaps lead to low open circuit voltages ({approximately}0.25 to 0.45 V) caused by high intrinsic carrier concentrations (n{sub i}{sup 2}). Thus, in order to obtain high performance. Photovoltaic cell temperatures must be kept near room temperature. This leads to ...
1999-03-01
Development of fire simulation models for radiative heat transfer and probabilistic risk assessment
Energy Technology Data Exchange (ETDEWEB)
An essential part of fire risk assessment is the analysis of fire hazards and fire propagation. In this work, models and tools for two different aspects of numerical fire simulation have been developed. The primary objectives have been firstly to investigate the possibility of exploiting state-of-the-art fire models within probabilistic fire risk assessments and secondly to develop a computationally efficient solver of thermal radiation for the Fire Dynamics Simulator (FDS) code. In the first part of the work, an engineering tool for probabilistic fire risk assessment has been developed. The tool can be used to perform Monte Carlo simulations of fires and is called the Probabilistic Fire Simulator (PFS). In Monte Carlo simulation, the simulations are repeated multiple times, covering the whole range of variability of the input parameters and thus resulting in a distribution of results covering what can be expected in reality. In practical ...
2008-07-01
Thermal radiation from hot surfaces measured by optical and calorimetric methods. Master's thesis
Energy Technology Data Exchange (ETDEWEB)
The radiative heat loss from a surface is determined by its total hemispherical emittance, which consequently plays an important role in aerospace and solar applications. This study compares emittances measured calorimetrically with values derived from near normal incidence spectral reflectance measurements. This optical derivation is based on a number of assumptions which limit the accuracy if not sufficiency fulfilled. These assumptions include sample specularity, a straybody character beyond the range of measurement, only small variations of emittance with temperature, and a perfectly smooth sample surface. The comparison of calorimetrically and optically derived emittance performed in this study not only quantifies the errors introduced by insufficient fulfillment of the assumptions but also identifies which assumption causes the dominant error. The calorimetric emissometer, constructed for this study and based on a heat flow sensor, was ...
1982-01-01
Regulation of naturally occurring radioactive materials in Australia
British Library Electronic Table of Contents (United Kingdom)
In order to promote uniformity between jurisdictions, the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) has developed the National Directory for Radiation Protection, which is a regulatory framework that all Australian governments have agreed to adopt. There is a large and diverse range of industries involved in mining or mineral processing, and the production of fossil fuels in Australia. Enhanced levels of naturally occurring radionuclides can be associated with mineral extraction and processing, other industries (e.g. metal recycling) and some products (e.g. plasterboard). ARPANSA, in conjunction with industry and State regulators, has undertaken a review and assessment of naturally occurring radioactive material (NORM) management in Australian industries. This rev...
2011-01-01
Proposal for a free electron laser driven by the 7 MeV NILPRP linac
International Nuclear Information System (INIS)
The proposal made in this paper refers to a free electron laser FEL with small-period electromagnet undulator in SASE regime and a FEL transverse optical klystron in the amplifier regime. The relativistic electron beam source for this FEL is the 7 MeV electron linac of the National Institute for Laser, Plasma and Physics Radiation (NILPRP) in Bucharest. The paper presents the main features of the design and performance of both FELs and discusses the improvements which must be made to the accelerator in order to use it as a free electron source concerning the injection system of electrons and formation of accelerated electron beam. The findings show that this FEL can be employed as a coherent radiation source in the IR range. (author)
Energy Technology Data Exchange (ETDEWEB)
The biological effects of ionizing radiation exposure are the result of a complex sequence of physical, chemical, biochemical, and physiological interactions. One way to begin a search for an understanding of health effects of radiation is through the development of phenomenological models of the response. Many models have been presented and tested in the slowly evolving process of characterizing cellular response. A range of models covering different endpoints and phenomena has developed in parallel. Many of these models employ similar assumptions about some underlying processes while differing about the nature of others. An attempt is made to organize many of the models into groups with similar features and to compare the consequences of those features with the actual experimental observations. It is assumed that by showing that some assumptions are inconsistent with experimental observations, the job of devising and ...
1990-09-01
Nuclear Battery As An Alternative Source Of Direct Current Electricity
International Nuclear Information System (INIS)
Nuclear battery produces electricity by converting radiation energy into electrical energy. Energy carried by particles emitted by a radioisotope nuclei is much higher than that released in chemical reaction. Reaction with nuclei can potentially produce electricity thousand to million times higher than that of chemical reaction. Unlike NPP that produces large scale alternating current using thermodynamic cycle such as Rankine or Brayton cycles, nuclear battery is designed like other battery or fuel cell, to produce direct current (DC). However, both battery utilize the energy or particles radiating from nuclei of a radioisotope. In this paper, several types of nuclear battery as an energy converter are discussed, including their working mechanisms and examples. Nuclear battery is potential to become a long-life power source for use in wide range of applications, including in medical areas and for instruments in remote areas ...
2000-11-01
Free electron laser inertial thermonuclear synthesis
International Nuclear Information System (INIS)
The paper proposes a concept of power driver for industrial thermonuclear reactor based on inertial thermonuclear synthesis (ITS). The circuit is based on the application of free electron laser (FEL) as a energy source for thermonuclear target compression which becomes feasible due to the application of a radically new circuit of FEL-amplifier. In the project under consideration the FEL-based laser system operates on the wave length of 0.5 micrometer. The full energy of laser radiation equals 1 MJ. This energy is delivered to the target in the pulse whose length is controlled within the range of 0.1-2 ns. The laser system brightness is 4 x 10"2"2 W cm"-"2. The FEL operating pulse repetition frequency is 40 Hz, full efficiency of electricity conversion into the energy of optical radiation is 11%. 9 refs., 3 figs., 2 tabs.
International Nuclear Information System (INIS)
The effect of both dopant and neutron radiation on the optical and thermal properties of polyvinyl chloride (PVC) has been studied. The doped samples with Pb and Cd were irradiated with a 14 MeV-neutron fluence in the range 7-28.8 x 10"9 n/cm"2. The optical energy gap E_o_p exhibits a significant dependence on the type of additive and the neutron irradiation fluence. The specific heat at constant pressure C_p showed a nonmonotonical change with radiation fluence. The results of this study show that PVC:Pb behaves as a crystalline structure which is only slightly affected by neutron irradiation, while PVC:Cd is highly affected. (author).
1994-11-01
Electronics Personal Dosemeter (EPD-N) Test and Evaluation Report
Energy Technology Data Exchange (ETDEWEB)
Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization then used at another site.
2003-04-08
Effect of some chemicals on the radiation-induced lipid peroxidation
International Nuclear Information System (INIS)
The effect of exposure to gamma rays on LPO contents in liver, spleen and kidney of mice and the anti-lipid-peroxidation of preparations of chinonin, tannic acid and squalene were reported. All these preparations were given by intragastric perfusion. For LPO, a modified method of TBA spectrophotometry was used for determination. The results show that LPO contents in tissues increased 72 h after whole-body exposure of mice to gamma rays, that in range of 0-4 Gy, there was a linear relationship between radiation doses and LPO contents, and that all three preparations were effective in reduction of the LPO content in liver, spleen and kidney of mice, with chinonin (at dose of 0.35 mg/mouse#centre dot#day) being more effective than tannic acid (at dose of 15 mg/mouse#centre dot#day) and squalene (at dose of 0.6 mg/mouse#centre dot#day).
Deep-level defects and numerical simulation of radiation damage in GaAs solar cells
Energy Technology Data Exchange (ETDEWEB)
A review of the deep-level defects observed in both electron- and proton-irradiated GaAs solar cells is presented. Studies of the effects of periodic and continuous thermal annealing on the radiation-induced electron and hole traps and the recombination parameters in GaAs solar cells were made for a wide range of electron and proton energies, fluence, annealing temperature and annealing time. A refined model for numerical simulations of the displacement damage was developed for computing the defect density and the cell parameters in the electron- and proton-irradiated GaAs solar cells. Excellent agreement was obtained between the calculated values and the experimental data for the proton-irradiated GaAs solar cells. (orig.).
1991-09-01
Atomic processes in high temperature plasmas
International Nuclear Information System (INIS)
Much theoretical and experimental efforts have been expended in recent years to study those atomic processes which are specially relevant to understanding high temperature laboratory plasmas. For magnetically confined fusion plasmas, the temperature range of interest spans from the hundreds of eV at plasma edges to 10 keV at the center of the plasma, where most of the impurity ions are nearly fully ionized. These highly stripped ions interact strongly with electrons in the plasma, leading to further excitation and ionization of the ions, as well as electron capture. Radiations are emitted during these processes, which easily escape to plasma container walls, thus cooling the plasma. One of the dominant modes of radiation emission has been identified with dielectronic recombination. This paper reviews this work.
1990-01-01
A radiation hardening model of 9%Cr-martensitic steels including dpa and helium
British Library Electronic Table of Contents (United Kingdom)
This paper provides a physically-based engineering model to estimate radiation hardening of 9%Cr-steels under both displacement damage (dpa) and helium. The model is essentially based on the dispersed barrier hardening theory and the dynamic re-solution of helium under displacement cascades but incorporating a number of assumptions and simplifications [Trinkaus, J. Nucl. Mater. 318 (2003) 234-340]. As a result, the kinetics of the damage accumulation kept fixed, its amplitude is fitted on one experimental condition. The model was rationalized on an experimental database that mainly consists of 9%Cr-steels irradiated in the range of 50-600degreeC up to 50dpa and with a He-content up to 5000appm. The test temperature effect is taken into account through a normalization procedure based on the...
2009-01-01
British Library Electronic Table of Contents (United Kingdom)
Abstract A highly efficient enzyme immobilization method has been developed for electrochemical biosensors using polydopamine films with gold nanoparticles (AuNPs) embedded. This simple enzyme fabrication method can be performed in very mild conditions and stored in a long time with high bioactivity. The fabricated amperometric glucose biosensor exhibited a high and reproducible sensitivity, wide linear dynamic range and low limit of detection (LOD) (0.1 molL-1). A low value of 1.5 mmolL-1 for the apparent Michaelis-Menten constant KappM was obtained. The high sensitivity, wide linear range, good reproducibility and stability make this biosensor a promising candidate for portable amperometric glucose biosensor.
2010-01-01
Flexible, all-organic ammonia sensor based on dodecylbenzene sulfonic acid-doped polyaniline films
International Nuclear Information System (INIS)
A stable chlorobenzene dispersion of conducting polyaniline (PANI) has been obtained by doping emeraldine base with dodecylbenzene sulfonic acid (DBSA) and studied by spectrophotometric measurements in the UV-vis-IR range. The electrical properties of PANI: DBSA films obtained from the above dispersion have been investigated under different temperature and relative humidity conditions. All-organic chemoresistive devices have been developed by spin-coating the PANI: DBSA dispersion on flexible substrates, and then by depositing electrodes on the top, from a carbon nanotube conducting ink. Sensing tests performed under exposition to calibrated amounts of ammonia reveal that these simple and inexpensive sensors are able to detect ammonia at room temperature in a reliable way, with a sensitivity linearly related to concentration in the range between 5 ppm and 70 ppm.
2010-09-30
British Library Electronic Table of Contents (United Kingdom)
Abstract In the work, a rapid, simple and high-throughput sample preparation method was developed for the determination of sulfonamide (SA) antibiotic residues in chicken breast muscle. The extraction and clean-up were online combined and up to 20 samples can be treated simultaneously in 6-min. The SAs were first extracted with acetonitrile under the action of microwave energy, and then the extract was directly introduced into the SPE column for on-line clean-up and concentration. Subsequently, the SAs eluted from the SPE column were determined by liquid chromatography-tandem mass spectrometry. The precisions of extraction results of 20 samples were in the range of 4.9-7.4%. The limits of detection and quantification obtained were in the range of 2.4-3.6-ng/g and 8.6-11.3-ng/g for SAs, res...
2011-01-01
A facile and green preparation of high-quality CdTe semiconductor nanocrystals at room temperature
Energy Technology Data Exchange (ETDEWEB)
One chemical reagent, hydrazine hydrate, was discovered to accelerate the growth of semiconductor nanocrystals (cadmium telluride) instead of additional energy, which was applied to the synthesis of high-quality CdTe nanocrystals at room temperature and ambient conditions within several hours. Under this mild condition the mercapto stabilizers were not destroyed, and they guaranteed CdTe nanocrystal particle sizes with narrow and uniform distribution over the largest possible range. The CdTe nanocrystals (photoluminescence emission range of 530-660 nm) synthesized in this way had very good spectral properties; for instance, they showed high photoluminescence quantum yield of up to 60%. Furthermore, we have succeeded in detecting the living Borrelia burgdorferi of Lyme disease by its photoluminescence image using CdTe nanocrystals.
2008-06-18
Kaluza-Klein Effects on Higgs Physics in Universal Extra Dimensions
Energy Technology Data Exchange (ETDEWEB)
We examine the virtual effects of Kaluza-Klein (KK) states on Higgs physics in universal extra dimension models. We study the partial widths {Lambda}{sub h{yields}gg}, {Lambda}{sub h{yields}{gamma}{gamma}}, and {Lambda}{sub h{yields}{gamma}Z}, which are relevant for Higgs production and detection in future collider experiments. These interactions occur at one loop in the Standard Model, as do the KK contributions. We find that the deviations induced by the KK exchanges can be significant; for one extra dimension, the gg {yields} h production rate is increased by 10% - 85% for the mass of the first KK state in the range 500 {approx}> m{sub 1} {approx}> 1500 GeV, a region untested by current direct search and precision measurement constraints. The h {yields} {gamma}{gamma} decay width is decreased by {approx}< 20% in the same mass range. For two or more universal extra dimensions the results are cutoff ...
2002-04-05
Inspection of PFR steam generators
International Nuclear Information System (INIS)
The inspection of PFR evaporator tubing, superheater and reheater tubing, and tube plate examinations, are described. Ferritic steel U tubes in the evaporator have been examined by an eddy current system operating at 400 kHz using flexible rotating probes. Surface defects as shallow as 0.1 mm can be detected and sized in the range 0.1 to 0.5 mm deep. An ultrasonic method is under development for wall thickness. Special test coil probes have been developed for examination of the type 316 stainless steel superheater and reheater tubing. Crack-life defects in the bore are detectable at approximately 10% wall thickness and 20% on the outside diameter. Tube plate examinations from the tube holes, have been conducted using eddy current probes which identify surface breaking cracks in the holes. For detecting curtain cracks between tube plate holes, ultrasonic compression wave probes have been used. (U.K.).
1976-03-09
Double-Edge Molecular Measurement of Lidar Wind Profiles in the VALID Campaign
We have developed a transportable container based direct detection Doppler lidar based on the double-edge molecular technique. The pulsed solid state system was built at the University of Geneva. It was used to make range resolved measurements of the atmospheric wind field as part of the VALID campaign at the Observatoire de Haute Provence in Provence, France in July 1999. Comparison of our lidar wind measurements, which were analyzed without knowledge of the results of rawinsonde measurements made under the supervision of ESA, show good agreement with these rawinsondes. These are the first Doppler lidar field measurements made with an eyesafe direct detection molecular-based system at 355 nm and serve as a demonstrator for future spaceborne direct detection wind systems such as the Atmospheric Dynamics mission. Winds are an important contributor to sea surface temperature measurements made with the ...
2000-01-01
Energy Technology Data Exchange (ETDEWEB)
Largest coal mine fires in the world are reported from Jharia coalfield in Dhanbad district, Bihar State of India. In this paper we report the utility of day and night time Thematic Mapper thermal IR data (120 m x 120 m) for detecting and monitoring mine fires in Jharia. For this purpose, seven sets of TM data acquired between 1985 to 1995 have been analysed. Data processing methods include geometric and radiometric corrections, conversion of DN values to at-satellite temperatures and colour coding of temperature images. The pixel-integrated temperatures of 50{degrees}C and above have been classified as mine fires and achieved an accuracy of 81.2%. Also, assessed year wise, colliery-wise and geological formation-wise mine fire distribution in this area. Although TM thermal data is of coarser resolution, it enabled detection of mine fires mainly because of the large areal extent and high temperature range of mine fires. It ...
1996-08-01
CZT vs FFT: Flexibility vs Speed
Energy Technology Data Exchange (ETDEWEB)
Bluestein's Fast Fourier Transform (FFT), commonly called the Chirp-Z Transform (CZT), is a little-known algorithm that offers engineers a high-resolution FFT combined with the ability to specify bandwidth. In the field of digital signal processing, engineers are always challenged to detect tones, frequencies, signatures, or some telltale sign that signifies a condition that must be indicated, ignored, or controlled. One of these challenges is to detect specific frequencies, for instance when looking for tones from telephones or detecting 60-Hz noise on power lines. The Goertzel algorithm described in Embedded Systems Programming, September 2002, offered a powerful tool toward finding specific frequencies faster than the FFT.Another challenge involves analyzing a range of frequencies, such as recording frequency response measurements, matching voice patterns, or displaying spectrum information ...
2003-10-01
The efficacy of low-dose radiation therapy and surgical resection for Ewing's sarcoma
International Nuclear Information System (INIS)
Purpose: To evaluate the effect of low-dose radiation therapy and surgery on local control in patients with Ewing's Sarcoma. Materials and Methods: Between 1979 and 1995 24 patients (ages 4-47) with Ewing's sarcoma were treated with combined modality therapy that included multi agent chemotherapy, surgical resection, and radiation therapy. Twelve patients had metastatic disease at the time of presentation (pleura = 3, lung = 5, bone 4). Tumor location was central in 16 and peripheral in 8. Multi agent chemotherapy consisted of vincristine/actinomycin D/cyclophosphamide/doxorubicin in 19. The same agents with the addition of ifosfamide and etoposide were given in 5. The extent of resection was considered to be radical in 14 and of the 16 patients who received preoperative chemotherapy, 5 were found to have a pathologic complete response. All patients with lung metastases at diagnosis received whole-lung irradiation to 1400 cGy in 10 fractions. ...
1996-09-01
International Nuclear Information System (INIS)
The objective of this study was to explore the role of three-dimensional (3-D) rotational angiography (RA) of the inferior vena cava (IVC; 3-D CV) before filter retrieval and its impact on treatment planning compared with standard anteroposterior cavography (sCV). Thirty patients underwent sCV and 3-D CV before IVC filter retrieval. Parameters assessed were: projection of filter arms or legs beyond the caval lumen, thrombus burden within the filter and IVC, and orientation of the filter within IVC. Skin and effective radiation doses were calculated. Statistical analysis was performed using paired Student t test and nonparametric McNemar's test. Standard anteroposterior cavography detected 49 filter arms or legs projecting beyond the caval lumen in 25 patients. Three-dimensional CV demonstrated 89 filter arms or legs projecting beyond the caval lumen in 28 patients. Twenty-two patients had additional filter arms or legs projecting beyond the ...
2009-01-01
New short-range electromagnetic current in the deuteron
International Nuclear Information System (INIS)
A new model for short-range isoscalar current in the deuteron and NN system is developed and tested on a variety of isoscalar magnetic observables such as the deuteron magnetic moment, magnetic form factor, and the circular polarization of photons at n"#->#p radiative capture at thermal neutron energies. The model for electromagnetic two-nucleon current proposed in the paper is based on generation of an intermediate dibaryon in the short-range NN interaction. This intermediate dibaryon, in turn, is treated within the new model for intermediate and short-range NN interaction recently proposed by the present authors. The transition current model developed here satisfies the current conservation relation by the construction. Our calculations have demonstrated that the new current model, using only one parameter (with a clear physical meaning), is able to describe, in very good agreement with the ...
2007-02-01
Simultaneous measurement of the neutron capture and fission yields of "2"3"3U
International Nuclear Information System (INIS)
We have measured the neutron capture and fission cross section of "2"3"3U at the neutron time-of-flight facility n-TOF at CERN in the energy range from 1 eV to 1 MeV with high accuracy by using a high performance 4#pi# BaF_2 Total Absorption Calorimeter (TAC) as a detection device. The method, based on the shape analysis of the TAC energy response, allowing to disentangle between #gamma#'s originating from fission and capture will be presented as well as the first very preliminary results. (authors)
2007-04-22
Semantic network array processor and its applications to image understanding
Energy Technology Data Exchange (ETDEWEB)
The problems in computer vision range from edge detection and segmentation at the lowest level to the problem of cognition at the highest level. This correspondence describes the organization and operation of a semantic network array processor (SNAP) as applicable to high level computer vision problems. The architecture consists of an array of identical cells each containing a content addressable memory, microprogram control, and a communication unit. The applications discussed in this paper are the two general techniques, discrete relaxation and dynamic programming. While the discrete relaxation is discussed with reference to scene labeling and edge interpretation, the dynamic programming is tuned for stereo.
1987-01-01
Radioimmunoassay of serum myoglobin in polymyositis and other conditions
International Nuclear Information System (INIS)
Radioimmunoassay of serum myoglobin was done in 53 patients with polymyositis syndromes and other conditions. Serum myoglobin values in 33 healthy subjects ranged from 4 to 77 [mean 33.3 +/- 19.8 (SD)] ng/ml. Fifty percent of polymyositis patients had elevated serum myoglobin levels (greater than 80 ng/ml). Serum myoglobin values in polymyositis patients fluctuated more sensitively than CPK and GOT. Combined estimation of myoglobin and CPK offers advantages for the detection of muscle injury and the prediction of disease exacerbation.
New techniques for electron-ion collision studies
International Nuclear Information System (INIS)
We have constructed an apparatus to study electron impact ionization of ions which should provide additional insight into the mechanisms involved. Using multiparameter coincidence techniques, we will detect both outgoing electrons from ionization process and will be able to analyze the momenta of both particles simultaneously. Coupled with a high resolution electron gun, this information should have broad application to the difficult problem of three bodies interacting via the long range Coulomb force. If sufficient accuracy can be achieved, information regarding the relative phase of the outgoing electron wavefunctions can be obtained.
Measurement of cosmic-ray low-energy antiproton spectrum with the first BESS-Polar Antarctic flight
The BESS-Polar spectrometer had its first successful balloon flight over Antarctica in December 2004. During the 8.5-day long-duration flight, almost 0.9 billion events were recorded and 1,520 antiprotons were detected in the energy range 0.1-4.2 GeV. In this paper, we report the antiproton spectrum obtained, discuss the origin of cosmic-ray antiprotons, and use antiprotons to probe the effect of charge sign dependent drift in the solar modulation.
2008-01-01
Directional wind-measurement derived from elastic backscatter lidar data in real-time
Energy Technology Data Exchange (ETDEWEB)
The development of a capability to infer wind velocities simultaneously at a number of ranges along one direction in real time is described. The elastic backscatter lidar data used was obtained using the XM94 lidar, developed by Los Alamos National Laboratory for the US Army Chemical and Biological Detection Command. In some respects this problem is simpler than measuring wind velocities on meso-meteorological scales. Other requirements, particularly high temporal fidelity, have driven the development of faster software algorithms and suggested opportunities for the evolution of the hardware.
1996-04-01
A multiple sampling proportional counter for particle identification of relativistic heavy ions
Energy Technology Data Exchange (ETDEWEB)
A multiple sampling dE/dx counter using a multiwire proportional chamber equipped with catbode pads was constructed for the multiple detection of dE/dx values along a particle trajectory. For low-energy particles this counter was proved to be useful as a Bragg-curve detector. At relativistic energies around E=14.6 GeV/nucleon good particle identification was obtained by cathode pad signals as well as anode signals for the range of projectile fragments from Z=1 (minimum ionization) up to a beam charge of Z=14. (orig.).
1990-11-15
The objectives of this study were to evaluate the performance of the NucliSens easyMAG platform for nucleic acid extraction from different clinical specimens compared to NucliSens miniMAG platform and manual QIAGEN extraction. The NucliSens easyMAG and the NucliSens miniMAG showed equal performance on 215 throat swabs since real-time nucleic acid sequence-based amplification scored the same samples positive for Mycoplasma pneumoniae (n=9) and Chlamydia pneumoniae (n=5) RNAs, although internal control RNA was slightly better detected with the NucliSens easyMAG (99.3% versus 96.8%). NucliSens easyMAG extracted nucleic acids more efficiently (higher recovery and/or fewer inhibitors) compared to QIAGEN extraction by showing, on average, lower Ct values in real-time LightCycler PCR, although 4 individual specimen out of 45 were found positive only with QIAGEN. For nine M. pneumoniae-positive throat swabs, the mean difference in Ct values between NucliSens easyMAG ...
2006-12-13
International Nuclear Information System (INIS)
Purpose: Patients with ataxia-telangiectasia (A-T) show greatly increased radiation sensitivity and cancer predisposition. Family studies imply that the otherwise clinically silent heterozygotes of this autosomal recessive disease run a 3.5 to 3.8 higher risk of developing cancer. In vitro studies suggest moderately increased cellular radiation sensitivity of A-T carriers. They may also show elevated clinical radiosensitivity. We retrospectively examined patients who presented with severe adverse reactions during or after standard radiation treatment for mutations in the gene responsible for A-T, ATM, considering a potential means of future identification of radiosensitive individuals prospectively to adjust dosage schedules. Material and Methods: We selected 20 cancer patients (breast, 11; rectum, 2; ENT, 2; bladder, 1; prostate, 1; anus, 1; astrocytoma, 1; Hodgkins lymphoma, 1) with Grade 3 to 4 (RTOG) acute and/or late ...
1999-07-15
International Nuclear Information System (INIS)
Although low-energy ion radiation has been proven to have a wide range of biological effects and led to fruitful achievements as a new mutagenic source for genetic modification, there still exist some disputes about its mutagenic mechanisms because of its short-penetrating property. In present research, Arabidopsis thaliana transgenic for GUS recombination substrate was used to evaluate the genomic instability induced by irradiations of alpha particle (3.3MeV) and Low-energy-Argon ion (30 KeV). A pronounced effects of alpha particle irradiation to Arabidopsis thaliana seedlings and Argon ion irradiation to seeds on the somatic homologous recombination frequency (sHRF) were reported. The sHRFs increased 1.88-fold and 2.42-fold, respectively, which indicated that the short-penetrating radiation could effectively induce the plant genomic instability in either dry seeds or seedlings with active metabolism. The local alpha ...
2008-08-12
International Nuclear Information System (INIS)
Radiation hardening and radiation-induced chromium (Cr) depletion were related to intergranular stress corrosion cracking (IGSCC) response among various stainless steels (SS). Available data on neutron-irradiated materials were analyzed and correlations developed between fluence, yield strength, grain-boundary Cr concentration, and cracking susceptibility in high-temperature water environments. Large heat-to-heat differences in the critical fluence (0.2 neutrons/cm"2 to 2.5 x 10"2"1 neutrons/cm"2) for IGSCC were documented. Variability often was consistent with yield strength differences among irradiated materials. IGSCC correlated better to yield strength than to fluence for most heats, suggesting a possible role for radiation-induced hardening (and microstructure) on cracking. However, isolated heats revealed a wide range of yield strengths (450 MPa to 800 MPa) necessary to promote IGSCC which could ...
International Nuclear Information System (INIS)
The TESLA Test Facility (TTF) at DESY is a facility producing sub-picosecond electron pulses for the generation of VUV or soft X-ray radiation in a free electron laser (FEL). The same electron pulses would also allow the direct production of high-power coherent radiation by passing the electron beam through an undulator. Intense, coherent far-infrared (FIR) undulator radiation can be produced from electron bunches at wavelengths longer than or equal to the bunch length. The source described in this paper provides, in the wavelength range 50-300 #mu#m, a train of about 1-10 ps long radiation pulses, with about 1 mJ of optical energy per pulse radiated into the central cone. The average output power can exceed 50 W. In this conceptual design, we intend to use a conventional electromagnetic undulator with a 60 cm period length and a maximum field of 1.5 T. The FIR ...
2001-12-21
The radon therapy - radon inhalatorium in Kowary
International Nuclear Information System (INIS)
In this paper the measurements of radon-222 concentration in the air of Kowary Radon Inhalatorium in the vicinity of Jelenia Gora, Lower Silesia, Poland, performed by Radiation Protection and Radiobiology Department of National Institute of Hygiene in Warsaw, have been presented. For the measurements the integration method with the application of charcoal canisters have been used. The radon concentration was found within the very broad ranges from about 4 to 420 kBq m"-"3 depending of the season of the year. Basing on the radon concentration measurements during the inhalation therapy session and taking into account the equilibrium factor of 0.8 the doses to the bronchi of the patients in range from 1.2 to about 204 mSv (0.12-20.4 rem) have been assessed. The majority of patients (ca. 76%) received the doses between 115 and 204 mSv. (author)
The PAMELA space experiment: first year of operation
Energy Technology Data Exchange (ETDEWEB)
On the 15th of June 2006 the PAMELA experiment, mounted on the Resurs DK1 satellite, was launched from the Baikonur cosmodrome and it has been collecting data since July 2006. PAMELA is a satellite-borne apparatus designed to study charged particles in the cosmic radiation, to investigate the nature of dark matter, measuring the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved, and to search for antinuclei with unprecedented sensitivity. The apparatus comprises a time-of-flight system, a silicon-microstrip magnetic spectrometer, a silicon-tungsten electromagnetic calorimeter, an anticoincidence system, a shower tail catcher scintillator and a neutron detector. The combination of these devices allows charged particle identification over a wide energy range.
2008-05-15
Simple calculation of daily photosynthesis by means of five photosynthesis-light equations
Energy Technology Data Exchange (ETDEWEB)
The performance of five well-known photosynthesis-light equations is compared by presenting a wide range of solutions in the form of dimensionless nomographs for the case where photosynthetically available radiation (PAR) reduces exponentially down the water column and is distributed sinusoidally through the photoperiod. These provide a simple means of calculating daily photosynthesis at any depth (e.g. at a benthic layer), or through a water column, avoiding the need to perform complex integrations. An examination is made of the accuracy of common approximate methods for calculating daily photosynthesis, assuming constant PAR. For optically deep water a modification is proposed to Talling's planimetric solution, to enable daily photosynthesis to be calculated more accurately, yet simply, over the whole range of possible PAR values. The errors induced by approximating the daily PAR distribution as a half-sinusoid ...
1992-12-01
Ewing's sarcoma of the vertebral column
International Nuclear Information System (INIS)
Twenty-two patients with vertebral primaries were registered in the Intergroup Ewing's Sarcoma Study between 1973 and 1977. The radiation doses to the primary tumors ranged between 3800 and 6200 rad. All patients received intensive combination chemotherapy. After a followup ranging between 14 and 62 months, 14 patients remained disease-free. All patients with primary tumor of the cervical and dorsal spine remained disease-free. Of eight patients with lesions in the distal spine, (sacrococcygeal region) six developed recurrence, in three a local recurrence was observed despite doses of 6000 rad or higher. Doses of 5000 rad or less (in addition to combination chemotherapy as used in the Intergroup Ewing's Study) appear adequate in controlling the primary tumors of the proximal segments of the spinal column.
Efficient, low emissions gas range cooktop
Energy Technology Data Exchange (ETDEWEB)
Disclosed is a gas-fired cooktop for a range which provides high thermal efficiency and low emissions of air pollutants, particularly low levels of NO{sub x}. The cooktop includes a perforated tile burner which radiates infrared energy upward at a high flux rate to rapidly quench burner gas temperatures and inhibit the formation of NO{sub x}. A perforated glass-ceramic jet plate positioned between the burner and a cooking vessel transmits most of the radiant infrared energy from the burner to the vessel and also forms jets of combustion products which are directed against the bottom of the vessel fo convective heating. Thermal efficiencies of up to about 70% and NO{sub x} emissions as low as about 15ppM are achieved by the cooktop.
1990-01-09
Recent developments and applications for the University of Texas thermal neutron imaging facility
Energy Technology Data Exchange (ETDEWEB)
The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system resolution have hot been determined. The TNIF is currently being revamped to begin work with the ...
2001-07-01
Thermal expansion of gamma irradiated nylon 66 from 10 K to 340 K
Energy Technology Data Exchange (ETDEWEB)
Samples of nylon 66 rods were irradiated using a cobalt-60 gamma ray source at a dose rate of 0.25 Mrad h[sup -1] in air at room temperature to a maximum dose of 500 Mrad. The linear coefficient of thermal expansion ([alpha]) was measured using a three-terminal capacitance technique reported previously. The variation of [alpha] with temperature between 10 K and 340 K was investigated for an unirradiated sample and two samples irradiated to 300 Mrad and 500 Mrad. In the range 10K to 160K, [alpha] is almost invariant with radiation dose and there is little difference between the values for the unirradiated and the 300 Mrad irradiated samples above 160 K. The sample irradiated to 500 Mrad does show a 6% increase in [alpha] over the other samples in the higher temperature range. All samples show an increase overall in the value of [alpha] with temperature. The melting point of each sample was also determined and was shown to ...
1994-08-15
Study of the Smith-Purcell effect in the relativistic regime
International Nuclear Information System (INIS)
We propose to investigate the spontaneous emission of radiation arising out of the interaction of a relativistic electron beam with a metallic grating (the Smith-Purcell effect). The work will concentrate, primarily, in the 50-120 #mu#m part of the infrared spectrum and will be an extension of the work begun by the Oxford-Dartmouth-Essex collaboration; one of the early objectives of the project will be to develop a quantitative understanding of the power spectrum of the emitted radiation over a wide range of emission angles. In particular, the limits of relativistic peaking of forward directed emission will be investigated. The electron beam will be produced by laser irradiation of a metallic cathode in the terminal of a small Van de Graff accelerator located in the Technische Universitaet, Muenchen. Beam energies will be in the range of 2 - 4 MeV. Initial tests on photoproduction of electrons have ...
1995-08-21
Radiation processing as a post-harvest quarantine control for raisins, dried figs and dried apricots
International Nuclear Information System (INIS)
The commercially packed samples of raisins, dried figs and dried apricots were irradiated using doses in the range of 0.5-1.0 kGy for disinfestation and 0.5-5.0 kGy for sensory analysis with the dose rate ranging from 1.44 to 1.92 kGy/h. Pests on dried fruits were evaluated after 0, 1, 2 and 3 months of storage for irradiated dried figs and 1, 3, 6 and 12 months of storage for raisins and dried apricots. Sensory analysis of dried figs, dried apricots and raisins were carried out after 0, 1, 3, 6 and 12 months of storage. The results indicated that radiation processing at low doses (#approx#1.0 kGy) is an effective post-harvest treatment and quarantine control for these products with no adverse effects on sensory (marketing) attributes.
2006-03-01
Broad-band stigmatic spectrograph for the soft x-ray range
International Nuclear Information System (INIS)
We describe a panoramic stigmatic spectrograph comprising a grazing-incidence toroidal mirror and a large-aperture free-standing transmission diffraction grating (5000 lines mm-1 ). Two spectrograph versions were constructed, with grazing angles of 7.6 and 40 and the short-wavelength spectral limits near 4 and 1.5 nm. The spectrograph aberrations were studied by numerical ray tracing. The spectrograph was used to record line and quasi-continuous spectra (1.5 - 30 nm) of multiply charged ions in a plasma generated by the second-harmonic pulses of an yttrium aluminate laser (Q = 0.15 J, ? = 5 ns, ? = 0.54 ?m, repetition rate = 0.5 Hz). In combination with a laser-produced plasma radiation source, the arrangement was used to characterise soft x-ray optical components and to generate collimated beams of polarised radiation in the 14 - 20 nm range. (laser applications and other topics in quantum electronics)
1998-09-30
Energy Technology Data Exchange (ETDEWEB)
Historical information about the F-Area Railroad Crosstie Pile is limited. The unit is believed to have been a borrow area for earth fill that began receiving railroad crossties during the 1960s. The number of crossties at the unit began to increase significantly in 1984 when major repair of the SRS rail system was initiated. An estimated 100,000 used railroad crossties have accumulated at the unit since 1984. In an effort to determine the impact of the railroad crossties on the environment a total of 28 soil samples were collected from four test borings in March of 1991. Sample depths ranged from ground surface to 21.5 feet. Three of the borings were extended to the water table and groundwater samples were collected, one in an upgradient ``background`` area, and two downgradient from the unit. Few analytes were reported above detection limits. Test results are summarized in Section 4.0 and analytes not detected are ...
1991-10-01
Preliminary characterization of the F-Area Railroad Crosstie Pile at the Savannah River Site
Energy Technology Data Exchange (ETDEWEB)
Historical information about the F-Area Railroad Crosstie Pile is limited. The unit is believed to have been a borrow area for earth fill that began receiving railroad crossties during the 1960s. The number of crossties at the unit began to increase significantly in 1984 when major repair of the SRS rail system was initiated. An estimated 100,000 used railroad crossties have accumulated at the unit since 1984. In an effort to determine the impact of the railroad crossties on the environment a total of 28 soil samples were collected from four test borings in March of 1991. Sample depths ranged from ground surface to 21.5 feet. Three of the borings were extended to the water table and groundwater samples were collected, one in an upgradient background'' area, and two downgradient from the unit. Few analytes were reported above detection limits. Test results are summarized in Section 4.0 and analytes not ...
1991-10-01
Energy Technology Data Exchange (ETDEWEB)
Martin Marietta Energy Systems, Inc. (Energy Systems) manages a closed hazardous waste disposal unit, Chestnut Ridge Security Pits (CRSP), in the form of two trenches and several auger-holes, located on top of the eastern portion of Chestnut Ridge at the Department of Energy (DOE) Oak Ridge Y-12 Plant in Tennessee. The groundwater monitoring system for the unit presently consists of a network of upgradient and downgradient monitor wells. To investigate the discharge of groundwater to springs and streams. An initial dye-tracer study was conducted during the driest part of 1990. The dye was detected at some of the monitoring sites, but verification was necessary due to the proximity of some sites to extraneous dye sources. A second dye-tracer was conducted during the wet weather season. The actual test commenced during the first week of February 1992 with a 4-week baseline monitoring period to determine the inherent variability of the emission spectra within the ...
1992-11-01
Opto-acoustic recanilization delivery system
Energy Technology Data Exchange (ETDEWEB)
Fiber delivered laser pulses emulsify thrombus by mechanical stresses that include a combination of pressure, tension and shear stress. Laser radiation is delivered to the locality of a thrombus and the radiation is absorbed by blood, blood dot, or other present materials. The combination of a leading pressure wave and subsequent vapor bubble cause efficient, emulsification of thrombus. Operating the laser in a low average power mode alleviates potential thermal complications. The laser is operated in a high repetition rate mode to take advantage of ultrasound frequency effects of thrombus dissolution as well as to decrease the total procedure time. Specific parameter ranges for operation are described. The device includes optical fibers surrounding a lumen intended for flow of a cooling agent. The fibers may be arranged concentrically around the lumen to deliver radiation and heat over as large an area ...
2002-01-01
Energy Technology Data Exchange (ETDEWEB)
A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL sheet was suggested to provide a convenient means of measuring the dose distribution ...
1991-06-01
Heat transfer augmentation due to surface radiative exchange effect of internal fins in an annulus
International Nuclear Information System (INIS)
Heat transfer augmentation due to surface radiation in an annulus with fins was investigated both theoretically and experimentally for fully developed laminar flow. The system considered in the present study was an array of axially internal and straight fins attached to the outer tube wall. Analytical solutions were given for 4, 8, 16, 24, 32 fins and for the ratios of the fin height to the passage clearance, 0, 0.2, 0.4, 0.5, 0.6, 0.8. The experiments were performed with air as the working fluid for radius ratio of 1.45, 16 fins and for Reynolds numbers ranging from 500 to 2000. The numerically predicted results of the convective/radiative heat transfer for the present case were in good agreement with the experimental data. It was found that the heat transfer augmentation coefficient attained a maximum value of 1.45 for 32 fins and for a dimensionless fin height of 0.65.
1987-08-01
Fused Silica Final Optics for Inertial Fusion Energy: Radiation Studies and System-Level Analysis
International Nuclear Information System (INIS)
The survivability of the final optic, which must sit in the line of sight of high-energy neutrons and gamma rays, is a key issue for any laser-driven inertial fusion energy (IFE) concept. Previous work has concentrated on the use of reflective optics. Here, we introduce and analyze the use of a transmissive final optic for the IFE application. Our experimental work has been conducted at a range of doses and dose rates, including those comparable to the conditions at the IFE final optic. The experimental work, in conjunction with detailed analysis, suggests that a thin, fused silica Fresnel lens may be an attractive option when used at a wavelength of 351 nm. Our measurements and molecular dynamics simulations provide convincing evidence that the radiation damage, which leads to optical absorption, not only saturates but that a 'radiation annealing' effect is observed. A system-level description is provided, including ...
2003-06-01
Computed radiography for major airway in pediatrics
International Nuclear Information System (INIS)
This paper shows the efficacy of computed radiography for major airway in pediatrics. For this purpose, we examined 40 children (range 2 weeks to 14 years; mean 2.3 years) using Fuji Computed Radiography (FCR) and radiation dose using pediatric phantom under FCR and conventional film and screen system. In comparison study with FCR and conventional film and screen system, FCR images are superior to conventional system in all cases. Scorings were done for the quality of the image of the pharynx, the trachea, and both main bronchi. In phantom study to check radiation dose, radiation dose could be reduced 1/6 of the value using high speed film and screen and 1/15 of the value using conventional speed film and screen. FCR also showed clear airway images in all cases but technical failure to evaluate the clinical lesion. These results suggest that FCR is the adequate imaging modality to evaluate the major ...
1986-01-01
Biological effects of low level exposures to chemicals and radiation
International Nuclear Information System (INIS)
In May 1990 a group of scientists representing several federal agencies, the International Society of Regulatory Toxicology and Pharmacology, the private sector, and academia met to develop a strategy to encourage the study of the biological effects of low level exposures (BELLE) to chemical agents and radioactivity. A workshop was held in 1991 with seven invited speakers focusing on the toxicological implications of biological adaptations. The selection of topics and speakers was designed to consider critically the concept of hormesis, not only in a broad, conceptual manner, but also at the molecular and biochemical levels. These presentations offered a complementary perspective on the diverse range of molecular mechanisms that can become activated at low levels of toxicant exposure. In addition to chemical toxicology research, an overview of current research on 'Effects of low-dose radiation on the immune response' was presented as well as ...
Additive effects common to radiation grafting and wood plastic composite formation
Energy Technology Data Exchange (ETDEWEB)
A range of additives has been developed for enhancing grafting yields in a variety of systems initiated by ionizing radiation. Cellulose has been adopted as the predominant naturally occurring model backbone polymer in these studies because of its structural relationship to wood which is the reference substrate for the work reported in the related second part of this paper concerning composites. Some experiments have been performed with the other major naturally occurring polymer, wool. For comparison purposes with synthetic materials, some studies have also been performed with polypropylene as trunk polymer. Styrene has been used as a predominant monomer in grafting with some experiments utilizing the acrulates like methyl methacrylate. The role of solvent in grafting has been evaluated. UV has been used as initiator to replace ionizing radiation for certain experiments. The additives used were mineral acids, lithium ...
1996-08-01
Towards optimal use of available technical resources for regulatory purposes. The Syrian experience
International Nuclear Information System (INIS)
The Atomic Energy commission of Syria (AECS) is nominated by Syrian legislation as the regulatory authority in respect of radiation protection and safety and security of radioactive sources. In addition AECS is providing a wide range of Technical Services (TS) through its various departments. In this paper, the cooperation and coordination between the regulatory authority and the providers of technical services in Syria are described. The adjustment of the regulatory programme as to make maximal use of the available technical resources is presented. It was shown that this relationship does not jeopardize the effective independency of the regulatory authority which is maintained by keeping the regulatory decisions based on pure regulatory considerations. (author)
2007-08-01
Properties of composite materials on the base of radiation-hardening binders and metal powders
International Nuclear Information System (INIS)
Compositions (oligomers with suitable properties and Al, Fe, Cu, Ta, W powders) were hardured by the flux of accelerated electrons at 10 mA beam current and 1.5 MeV energy. Dielectric and mechanical properties of metal-filled polymeric compositions as well as their radioply sicl properties in SHF-range are studied. It is shown that the produced compositions belong tot he absorbing protective materials in which the protection effect is mainly achieved through the absorption losses. 6 refs.; 3 tabs.
International Nuclear Information System (INIS)
A key comparison has been made between the air-kerma standards of the ARPANSA and the BIPM in the low-energy X-ray range. The results show the standards to be in agreement at the level of the combined standard uncertainty of 7.0 parts in 10"3 for the 10 kV radiation quality and 3.7 parts in 10"3 for all other beam qualities. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. (authors)
2010-12-01
Focusing and resonance properties of two-dimensional small-size hemielliptic lenses made of different materials are studied numerically in order to estimate the influence of internal reflections on the radiation characteristics of dielectric lens antennas. Accuracy of in-house made algorithms based on combination of geometrical and physical optics and FDTD in the analysis of optical and modal effects in the behavior of such lenses is tested by comparison with the exact solution obtained using the Muller boundary integral equations. The range of applicability for the approaches is discussed.
2010-01-01
International Nuclear Information System (INIS)
The additional error in measurement of the thickness of Kh18N10T steel for possible changes in composition with an energy of the photons of ionizing radiation of 10-80 keV was evaluated. The desirability of use of a type REIS-I x-ray emitter in measurement of the thickness of steel up to 1 mm is shown. The instrument provides measurement of the thickness of steel in the 0.1-1.0 mm range with a reproducibility of the results with an error not exceeding 0.5-1.0%. The measurement error with corrugations characteristic of bellows does not exceed 5%.
Induction of sterility in adults of Earias vittella Fabricius through late pupal irradiation
International Nuclear Information System (INIS)
Studies on pupal irradiation of Earias vittella Fabricius, were undertaken to determine the optimum dose for sterile and competitive adults. Late pupae were irradiated with gamma radiation doses ranging from 150 to 300 Gy. Emerging adults were normal and without malformation. When males that emerged from irradiated pupae were crossed with normal female, fecundity as well as longevity was comparable to control, but there was drastic reduction in percent egg hatch in all the treatments. However, when females emerging from irradiated pupae were crossed with normal male, there was reduction in the fecundity as well as fertility and this effect was dose dependent. (author).
Gastrointestinal radiography using Fuji computed radiography (FCR)
International Nuclear Information System (INIS)
Initial clinical experience in gastrointestinal radiography using Fuji Computed Radiography(FCR) system was reported. Image quality of conventional film/screen radiography and FCR system on upper GI series and barium enema was compared. Reflecting wide dynamic range of the system, improved image quality was confirmed, particularity in visibility of fine mucosal pattern(area gastricae), folds and overall contour. High sensor sensitivity of the system could reduce radiation dose requirement significantly. Diagnostically acceptable images were obtained with approximately 1/5 of routine dose for conventional radiography except in cases of lateral view of the rectum. (author).
1985-01-01
EXAFS Study of Semimetal-Semiconductor Transition of Bismuth Clusters
International Nuclear Information System (INIS)
Extended X-ray absorption fine structure (EXAFS) measurements of bismuth clusters in the temperature range of 23 -300 K have been performed using synchrotron radiation in order to investigate the size dependent phase transition. The inter-atomic distances around 3.0 A and 3.6 A are attributed to the nearest neighbors within the layer and between layers, respectively. EXAFS functions were analysed by the curve fitting method within a symmetric distribution approximation. The nearest neighbor distance of the 0.5 nm thick films is shorter than that of the 300 nm thick films at all the temperatures, which is related to the reduction of the inter-layer correlation.
2007-02-02
Billion particle linac simulations for future light sources
Energy Technology Data Exchange (ETDEWEB)
In this paper we report on multi-physics, multi-billion macroparticle simulation of beam transport in a free electron laser (FEL) linac for future light source applications. The simulation includes a self-consistent calculation of 3D space-charge effects, short-range geometry wakefields, longitudinal coherent synchrotron radiation (CSR) wakefields, and detailed modeling of RF acceleration and focusing. We discuss the need for and the challenges associated with such large-scale simulation. Applications to the study of the microbunching instability in an FEL linac are also presented.
2008-09-25
Acoustic response of piezoelectric lead-zirconate-titanate to a 400MeV/n xenon beam
Energy Technology Data Exchange (ETDEWEB)
Characteristics of lead-zirconate-titanate (PZT) elements were studied by directly irradiating them with a 400 MeV/n Xe beam. The elements were sensitive to 10{sup 4} Xe ions and their output amplitudes were proportional to the beam intensity. An ensemble of those output amplitudes displayed a Bragg-curve-like response towards the range of 400 MeV/n Xe ion. We discuss the potential of PZT elements as a radiation detector and their application to high-intensity and high-energy detectors. (author)
2003-03-01
A new type active personal dosemeter with a solid state detector
International Nuclear Information System (INIS)
We have developed a new type personal dosemeter by using a B-10 doped silicon p-n junction detector with a polyethylene radiator and a polyethylene moderator. The purpose of this study was to develop a real time neutron dosemeter with a nearly flat response in the energy range from thermal to 15 MeV and low angular dependence to the incident neutron direction. The neutron response of the dosemeter was obtained with the Monte Carlo calculation and the monoenergetic neutron experiment in a free air field and also under a condition attached on a phantom.
1988-04-01
Quantitative imaging of turbulent and reacting flows
Energy Technology Data Exchange (ETDEWEB)
Quantitative digital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitative image data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial dynamic range, signal-to-noise ratio and spatial resolution in the imaging system as well as developing ...
1993-12-01
X-ray, Optical, and Radio Observations of SN 1999em and SN 1998S
Observations of the Type II-P (plateau) Supernova (SN) 1999em and Type IIn (narrow emission line) SN 1998S have enabled estimation of the profile of the SN ejecta, the structure of the circumstellar medium (CSM) established by the pre-SN stellar wind, and the nature of the shock interaction. SN 1999em is the first and only Type II-P detected at both X-ray and radio wavelengths. It is the least radio luminous and one of the least X-ray luminous SN ever detected (except for the unusual and very close SN 1987A). The Chandra X-ray data indicate non-radiative interaction of SN ejecta with a power-law density profile (rho \\propto r^{-n} with n ~ 7) with a pre-SN wind with a low mass loss rate of ~2 \\times 10^{-6} Msun/yr for a wind velocity of 10 km/sec, in close agreement with radio mass-loss rate estimates. The Chandra data show an unexpected, temporary rise in the 0.4--2.0 keV X-ray flux at ~100 days after explosion. SN ...
2001-01-01
Validating eddy current array probes for inspecting steam generator tubes
International Nuclear Information System (INIS)
A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. Methods are presented for ...
1997-11-16
Validating eddy current array probes for inspecting steam generator tubes
Energy Technology Data Exchange (ETDEWEB)
A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. Methods are presented for ...
1997-07-01
The influence of salt aerosol on alpha radiation detection by WIPP continuous air monitors
Energy Technology Data Exchange (ETDEWEB)
Alpha continuous air monitors (CAMs) will be used at the Waste Isolation Pilot Plant (WIPP) to measure airborne transuranic radioactivity that might be present in air exhaust or in work-place areas. WIPP CAMs are important to health and safety because they are used to alert workers to airborne radioactivity, to actuate air-effluent filtration systems, and to detect airborne radioactivity so that the radioactivity can be confined in a limited area. In 1993, the Environmental Evaluation Group (EEG) reported that CAM operational performance was affected by salt aerosol, and subsequently, the WIPP CAM design and usage were modified. In this report, operational data and current theories on aerosol collection were reviewed to determine CAM quantitative performance limitations. Since 1993, the overall CAM performance appears to have improved, but anomalous alpha spectra are present when sampling-filter salt deposits are at normal to high levels. This report shows that ...
1996-01-01
Reactivity differences of hydroxyl radicals and hydrated electrons in destructing azo dyes
International Nuclear Information System (INIS)
The high-energy radiation-induced degradation of an H-acid derivative azo dye, Apollofix-Red SF-28 (AR-28) was studied in aqueous solution by using pulse radiolysis with kinetic spectroscopic detection for transient measurements. Gamma radiolysis with UV-VIS spectroscopy and gradient ionpair HPLC separation with diode array detection were applied for following the destruction of AR-28 and measuring the products. The reactions of hydrated electron (e_a_q "-) and hydroxyl ("#centre dot#OH) radical were investigated separately. "#centre dot#OH reacts with the unsaturated bonds of the molecule. In the further reactions of the "#centre dot#OH adduct radicals, the AR-28 molecules partly reform with a slightly modified structure. The products formed in the first reaction of "#centre dot#OH and AR-28 molecules have also high reactivity towards the "#centre dot#OH radicals. For these reasons the efficiency of "#centre dot#OH ...
High resolution Computed Tomography in the study of temporal bone trauma
International Nuclear Information System (INIS)
Thirty-five patients with temporal bone fractures were examined; the fractures were sometimes associated with dislocation of the assicular chain caused by road fatalities. Computed Tomography (CT) was performed either because of the presence of clinical symptoms associated with trauma of the temporal bone, because of a hemotympanum discovered during a CT scan of the brain. Thirty-three fractures were detected: 19 longitudinal, 6 transverse, and 8 complex. An incudostapedial dislocation was also detected, together with a displacement of a stapedial prosthesis from the lenticular process of incus, and 3 incus-malleus dislocation associated with fractures. High resolution CT allows the precise definition of the course of the fractures, of the associated dislocation of the ossicular chain, and of facial nerve lesion, thus allowing a more accurate surgical intervention. In the examination of the temporal bone, high resolution CT is preferible to ...
1988-01-01
Energy Technology Data Exchange (ETDEWEB)
A new method is being developed to quickly screen for the human exposure potential to polycyclic aromatic hydrocarbons (PAHs) and organochlorines (OCs). The development involves two key elements: identifying suitable signals that represent intracellular changes that are specific to PAH and OC exposure, and constructing a device to guide the biological cell growth so that signals from individual cells are consistent and reproducible. We are completing the identification of suitable signals by using synchrotron radiation-based (SR) Fourier-transform infrared (FTIR) spectromicroscopy in the mid-infrared region (4000-400 cm-1). Distinct changes have been observed in the IR spectra after treatment of human cells in culture medium with PAHs and OCs. The potential use of this method for detecting exposure to PAHs and OCs has been tested and compared to a reverse transcription polymerase chain reaction (RT-PCR) assay that quantifies increased ...
1999-01-10
Automated method for determining location and magnitude of leaks inside a PWR containment
Energy Technology Data Exchange (ETDEWEB)
Thermal-hydraulics analysis can be used to determine location and magnitude of leaks inside a pressurized water reactor (PWR) containment, as required by plant technical specifications. The major advantage of this detection method is that it minimizes radiation exposure of maintenance personnel because most of the leak detection process is performed from the control room outside the containment. In addition, such a program allows for the elimination of pipe whip restraints and jet impingement shields, eliminating costs for maintenance of these supports and shields in older plants and lowering construction costs for new plants. Previously, only simple single-node containment models were used for determining leakage magnitude. This paper presents a more sophisticated multinode approach for determining the magnitude and location. The resulting sensitivities to leak can be programmed into the plant's computer system. ...
1986-01-01
Detection by cationized /sup 125/I-cytochrome C of proteoglycans (PG) transferred to nylon
Energy Technology Data Exchange (ETDEWEB)
Cytochrome c, labeled with /sup 125/I, has been used by us for staining glycosaminoglycans (GAG) separated by electrophoresis on cellulose acetate strips. As GAG between 1-10 ng could be quantified by autoradiography and densitometry, the reagent is approximately 100-fold more sensitive than currently used non-radiolabeled stains. The authors extend now the use of radiolabeled cytochrome c to the quantification of PG transblotted to solid supports subsequent to separation on polyacrylamine slab gels. Dot blotting used for exploring optimal conditions for detecting PG indicated that because of low background positively charged Nylon 66 was superior to nitrocellulose. Increasing the positive charge of the staining reagent by cationization decreased background radiation even further so that 1 ng PG could be seen readily after 5 hrs of autoradiography. Use of cationized /sup 125/I-cytochrome c has been made in detecting PG of ...
1986-05-01
In 2002 and again in 2003, an investigative journalist unit at ABC News transported a 6.8 kilogram metallic slug of depleted uranium (DU) via shipping container from Istanbul, Turkey to Brooklyn, NY and from Jakarta, Indonesia to Long Beach, CA. Targeted inspection of these shipping containers by Department of Homeland Security (DHS) personnel, included the use of gamma-ray imaging, portal monitors and hand-held radiation detectors, did not uncover the hidden DU. Monte Carlo analysis of the gamma-ray intensity and spectrum of a DU slug and one consisting of highly-enriched uranium (HEU) showed that DU was a proper surrogate for testing the ability of DHS to detect the illicit transport of HEU. Our analysis using MCNP-5 illustrated the ease of fully shielding an HEU sample to avoid detection. The assembly of an Improvised Nuclear Device (IND) -- a crude atomic bomb -- from sub-critical pieces of HEU metal was then examined ...
2007-04-01
Systems Analysis of Safeguards Effectiveness in a Uranium Conversion Facility
Energy Technology Data Exchange (ETDEWEB)
The U.S. Department of Energy (DOE) is interested in developing tools and methods for potential U.S. use in designing and evaluating safeguards systems. For this goal several DOE National Laboratories are defining the characteristics of typical facilities of several size scales, and the safeguards measures and instrumentation that could be applied. Lawrence Livermore National Laboratory is providing systems modeling and analysis of facility and safeguards operations, diversion path generation, and safeguards system effectiveness. The constituent elements of diversion scenarios are structured using directed graphs (digraphs) and fault trees. Safeguards indicator probabilities are based on sampling statistics and/or measurement accuracies. Scenarios are ranked based on value and quantity of material removed and the estimated probability of non-detection. Significant scenarios, especially those involving timeliness or randomly varying order of events, are transferred ...
2004-06-16
We discuss the estimation of galaxy correlation properties in several volume limited samples, in different sky regions, obtained from the Fourth Data Release of the Sloan Digital Sky Survey. The small scale properties are characterized through the determination of the nearest neighbor probability distribution. By using a very conservative statistical analysis, in the range of scales [0.5,~30] Mpc/h we detect power-law correlations in the conditional density in redshift space, with an exponent \\gamma=1.0 \\pm 0.1. This behavior is stable in all different samples we considered thus it does not depend on galaxy luminosity. In the range of scales [~30,~100] Mpc/h we find evidences for systematic unaveraged fluctuations and we discuss in detail the problems induced by finite volume effects on the determination of the conditional density. We conclude that in such range of scales there is an evidence for a ...
2006-01-01
Study on dose distribution of therapeutic proton beams with prompt gamma measurement
Energy Technology Data Exchange (ETDEWEB)
The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma distribution was compared to the dose distribution measured by an ionization chamber at three different ...
2007-03-15
Whole-body counting in the Marshall Islands
Energy Technology Data Exchange (ETDEWEB)
In 1978 the Marshall Islands Radiological Safety Program was organized to perform radiation measurements and assess radiation doses for the people of the Bikini, Enewetak, Rongelap and Utirik Atolls. One of the major field components of this program is whole- body counting (WBC). WBC is used to monitor the quantity of gamma- emitting radionuclides present in individuals. A primary objective of the program was to establish {sup 137}Cesium body contents among the Enewetak, Rongelap and Utirik populations. {sup 137}Cs was the only gamma-emitting fission radionuclide detected in the 1,967 persons monitored. {sup 137}Cs body burdens tended to increase with age for both sexes, and were higher in males. The average {sup 137}Cs dose Annual Effective Dose for the three populations was as follows: For Enewetak, the dose was 22{+-}4 {mu}Sv. For Utirik, the dose was 33{+-} 3 {mu}Sv. Since 1985 the Rongelap people have been self-exiled ...
1991-01-01
International Nuclear Information System (INIS)
We report on the first measurements of the z-dependent evolution of electron-beam microbunching as revealed through coherent transition radiation (CTR) measurements in a visible self-amplified spontaneous emission free-electron laser experiment. The increase in microbunching was detected by tracking the growth of the visible CTR signals as generated from insertable metal mirrors/foils after each of the last three undulators. The same optical imaging diagnostics that were used to track the z-dependent intensity of the undulator radiation (UR) were also used to track the electron beam/CTR information. Angular distribution, beam size, and intensity data were obtained after each of the last three undulators in the five-undulator series, and spectral information was obtained after the last undulator. The exponential growth rate of the CTR was found to be very similar to that of the UR and consistent with simulations using the ...
2002-07-01
International Nuclear Information System (INIS)
We report on the first measurements of the z-dependent evolution of electron-beam microbunching as revealed through coherent transition radiation (CTR) measurements in a visible self-amplified spontaneous emission free-electron laser experiment. The increase in microbunching was detected by tracking the growth of the visible CTR signals as generated from insertable metal mirrors/foils after each of the last three undulators. The same optical imaging diagnostics that were used to track the z-dependent intensity of the undulator radiation (UR) were also used to track the electron beam/CTR information. Angular distribution, beam size, and intensity data were obtained after each of the last three undulators in the five-undulator series, and spectral information was obtained after the last undulator. The exponential growth rate of the CTR was found to be very similar to that of the UR and consistent with simulations using the ...
2001-12-21
Synchrotron Self-Compton Analysis of TeV X-ray Selected BL Lacertae Objects
We introduce a methodology for analysis of multiwavelength data from X-ray selected BL Lac (XBL) objects detected in the TeV regime. By assuming that the radio--through--X-ray flux from XBLs is nonthermal synchrotron radiation emitted by isotropically-distributed electrons in the randomly oriented magnetic field of a relativistic blazar jet, we obtain the electron spectrum. This spectrum is then used to deduce the synchrotron self-Compton (SSC) spectrum as a function of the Doppler factor, magnetic field, and variability timescale. The variability timescale is used to infer the comoving blob radius from light travel-time arguments, leaving only two parameters. With this approach, we accurately simulate the synchrotron and SSC spectrum of flaring XBLs in the Thomson through Klein-Nishina regimes. Photoabsorption by interactions with internal jet radiation and the intergalactic background light (IBL) is included. Doppler ...
2008-01-01
International Nuclear Information System (INIS)
Non-destructive methods of diagnosis for detecting cable degradation by aging are being studied recently for improvement of electric wires and cables. This study examines degradation behaviors of cable sheath and insulation by combined accelerated aging tests applying thermal and radiation stresses simultaneously using a typical low voltage cable. According to experiments, elongation of cross-linked polyethylene insulation deteriorated at a faster rate than PVC sheath did under low doses below 50 Gy/h. Therefore, measurements using a time domain dielectric spectrometer (TDS) were carried out for the purpose of developing a method of degradation diagnosis of insulation. It was found that values of tan#delta# measured at very low frequencies below 0.1 Hz increase in pace with degradation of insulation reflecting the level of degradation more effectively than those measured at frequencies around the commercial frequency. In order to consider ...
2000-05-01
Gap-junctional communication of bone marrow stromal cells is resistant to irradiation in vitro
Energy Technology Data Exchange (ETDEWEB)
Bone marrow is one of the most radiosensitive organs. Irradiation causes a marked decrease in the total number of hematopoietic cells in the bone marrow. The reticular meshwork structure of marrow stromal cells, however, is relatively resistant to irradiation. Unimpaired stromal cell structure has been thought to be a prerequisite for the repopulation of hematopoietic cells during recovery from the effects of irradiation. The reticular framework is maintained by cell adhesion apparatuses such as gap junctions. The in vitro radiobiologic survival values of a cloned stromal cell line, H-1/A, were studied (n = 1.8, D0 = 138 cGy). Radiation doses of up to 4000 cGy had no detectable effects on the production of colony-stimulating factor 1. H-1/A cells communicate with each other via gap junctions as determined by the sensitive dye-transfer method. Gap-junctional communication between H-1/A cells was resistant to different levels of irradiation (500 ...
1990-10-01
Gap-junctional communication of bone marrow stromal cells is resistant to irradiation in vitro
International Nuclear Information System (INIS)
Bone marrow is one of the most radiosensitive organs. Irradiation causes a marked decrease in the total number of hematopoietic cells in the bone marrow. The reticular meshwork structure of marrow stromal cells, however, is relatively resistant to irradiation. Unimpaired stromal cell structure has been thought to be a prerequisite for the repopulation of hematopoietic cells during recovery from the effects of irradiation. The reticular framework is maintained by cell adhesion apparatuses such as gap junctions. The in vitro radiobiologic survival values of a cloned stromal cell line, H-1/A, were studied (n = 1.8, D0 = 138 cGy). Radiation doses of up to 4000 cGy had no detectable effects on the production of colony-stimulating factor 1. H-1/A cells communicate with each other via gap junctions as determined by the sensitive dye-transfer method. Gap-junctional communication between H-1/A cells was resistant to different levels of irradiation (500 ...
ESR dosimetry of irradiated chicken legs and chicken eggs
Energy Technology Data Exchange (ETDEWEB)
Ionising radiation induces stable free radicals in chicken bones and in the shell of chicken eggs which can be detected, by the electrons spin resonance (ESR) technique, well beyond the shelf-life of the food and can be used for dosimetry. The method usually adopted to evaluate ``a posteriori`` the dose given during the ionising radiation treatment of food, is the dose additive method. To assess the dose, the ESR signal amplitude of the irradiated food (bone or egg shell in the present case) is measured and then the dose-effect relationship is obtained by re-irradiating the sample with some additive doses (usually of 1 kGy). The dose-effect curve is back-extrapolated and the initial given dose determined. At the Istituto Superiore di Sanita (ISS), Rome, Italy, a research programme was approved two years ago aimed to, (1) study new methodological approaches for ESR dose assessment, and (2) analyse the factors which may ...
1996-12-31
Air conditioner for radioactive material handling facility
Energy Technology Data Exchange (ETDEWEB)
An air conditioner intakes open-air from an open-air intake port to remove sands and sea salt particles by air filters. Then, natural and artificial radioactive particles of less than 1 {mu}m are removed by high performance particulate filters. After controlling the temperature by an air heater or an air cooler, air is sent to each of chambers in a facility under pressure elevation by a blower. In this case, glass fibers are used as the filter material for the high performance particulate filter, which has a performance of more than 99.97% for the particles of 0.3 {mu}m grain size. Since this can sufficiently remove the natural radioactive materials intruded from the outside, a detection limit value in each of the chambers of the facility can be set 10{sup -13} to 10{sup -14} {mu}ci/cm{sup 3} in respect of radiation control. Accordingly, radiation control can be conducted smoothly and appropriately. (I.N.).
1991-04-26
Theoretical considerations for X-ray phase contrast mammography by Thomson source
Energy Technology Data Exchange (ETDEWEB)
The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase imaging with respect to standard absorption imaging, in the specific case of ...
2009-09-01
TeV gamma-rays from the Northern sky pulsar wind nebulae
Energy Technology Data Exchange (ETDEWEB)
We estimate the TeV {gamma}-ray fluxes expected from the population of young pulsars in terms of the self-consistent time-dependent hadronic-leptonic model for the high-energy processes inside the pulsar wind nebulae (PWNe). This radiation model is based on the hypothesis of Arons and collaborators who postulate that leptons are accelerated inside the nebulae as a result of resonant scattering on heavy nuclei, which in turn are accelerated in the pulsar wind region or the pulsar inner magnetosphere. Our aim is to find out which PWNe on the northern hemisphere are the best candidates for detection at energies above 60 GeV and 200 GeV by the next generation of low-threshold Cherenkov telescopes.
2005-12-01
Energy Technology Data Exchange (ETDEWEB)
Metallic nanoparticles was synthesized in SiO{sub 2} matrices by means of a process of two stages. The first one proceeded via sol-gel, incorporating the metallic precursors to the reaction system before the solidification of the matrix. Later on, the samples underwent a thermal treatment in atmosphere of H{sub 2}, carrying out the reduction of the metals that finally formed to the nanoparticles. Then it was detected the presence of smaller nanoparticles than 20 nm, dispersed and with the property of being liberated easily of the matrix, conserving a free surface, chemically reactive and with response to external electromagnetic radiation. The system SiO{sub 2}-Pd showed an important thermoluminescent response. (Author)
2004-07-01
Spectroscopy of gadolinium gallium garnet crystals doped with Y b3+ revisited
International Nuclear Information System (INIS)
The optical spectroscopy measurements of gadolinium gallium garnet (GGG) crystals doped with Yb show evidence of the presence of non-equivalent optical centers with very similar radiative decay rates. The energy level schemes of those centers have been determined on the basis of optical absorption, luminescence and Raman experiments. Crystal field fitting resulted in two sets of slightly different crystal field parameters for two non-equivalent Yb centers. Both sets of parameters describe perfectly the experimentally detected Y b3+ energy levels. Correlation between systematic trends in the experimental energy level schemes and crystal field parameters is discussed.
2010-06-30
Reduction of fluoroscopic exposure for the air-contrast barium enema
Energy Technology Data Exchange (ETDEWEB)
In a fluoroscopic imaging system, image quality and patient dose are both affected by the optical system linking the image intensifier with the video camera. The effect on patient exposure of increasing the optical iris aperture size over that required for other procedures performed on the same imaging system was investigated for the air-contrast barium enema examination. Using a large-area transmission ionisation chamber to monitor the Roentgen-area-product of entrance exposure, a decrease in fluoroscopic radiation of greater than 50% was clinically documented for a fluoroscopic system utilising kVp and mA variable automatic brightness control. For this iris change, the video image was of acceptable quality for positioning and monitoring the patient, and no deleterious effect was detected in the conduct of the air-contrast exam. The availability of a variable-sized operator-selectable iris diaphragm would permit this dose-reduction approach to ...
1983-11-01
International Nuclear Information System (INIS)
Radiological and environmental protection experience associated with the reactor cover gas processing system at the Fast Flux Test Facility (FFTF) has been excellent. Personnel radiation exposures received from operating and maintaining the reactor cover gas processing system have been very low, the system has remained free of radioactive particulate contamination through the first seven operating cycles (cesium contamination was detected at the end of Cycle 8A), and releases of radioactivity to the environment have been very low, well below environmental standards. This report discusses these three aspects of fast reactor cover gas purification over the first eight operating cycles of the FFTF (a duration of a little more than four years, from April 1982 through July 1986).
1986-09-24
Quantitative measurement of elements in a composite, using multienergy gamma-rays
International Nuclear Information System (INIS)
This study is an attempt to measure the quantities of elements in a composite by irradiating that composite with #gamma#-rays of various energies and detecting the transmitted radiation through the composite. A previous knowledge of the number of the elements and their attenuation coefficients is required. The quantities are calculated by solving the matrix of a linear system of equations. A computer program was developed to select the best combinations of the available energies. Five criteria were established to determine these energy combinations: (i) the determinant of the attenuation coefficient matrix; (ii) the condition number, (iii) the number of times the solution of the matrix leads to acceptable results; (iv) the indicator, (a new concept); (v) the standard deviations of the results. The intended application of this technique in medicine is to measure the bone mineral content of the skeleton. An examination of the error propagation, ...
Energy Technology Data Exchange (ETDEWEB)
Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A /sup 238/Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed.
1981-01-01
Instruments for X-ray fluorescence analysis and spectrometry
International Nuclear Information System (INIS)
The radionuclide X-ray fluorescence analyzer consists of a source changer and a sample changer. "5"5Fe, "1"0"9Cd and "2"4"1Am are used as excitation sources. The radiation is detected with a semiconductor Si(Li) detector. The complete assembly of the apparatus consists of an imagine unit, a keyboard, a floppy disc drive, a printer, a console and a rack with analog and digital electronics. Its multichannel amplitude analyzer consists of power supplies, a high voltage supply, a linear amplifier, an analog-to-digital converter and a computer. The technical specifications are given. The control and data processing system is controlled with an MHB 8080A microprocessor. Software for semiconductor gamma spectrometry and for quantitative gamma spectrometry will be supplied with the equipment. (E.S.). 3 figs., 4 refs.
International Nuclear Information System (INIS)
Increased levels of epidermal growth factor receptor have been reported in a variety of tumors, including pulmonary squamous cell carcinomas in man. The purpose of this study was to determine if increased levels of epidermal growth factor (EGFR) were present in lung tumors from Beagle dogs that had been exposed to "2"3"9PuO_2- Using immunohistochemical techniques, sections from 17 lung tumors were examined for the presence of EGFR. Seven of the tumors were strongly positive for EGFR; the remainder of the tumors and the normal lung sections were negative. The positive immunostaining could not be correlated with the histologic phenotype of the tumors. Work is in progress to determine the level of EGFR in preneoplastic, proliferative epithelial foci in the Iung. (author)
1988-12-01
Experiments on determination of damage effect ions "2"2Ne (172 MeV) on UO_2 monocrystals
International Nuclear Information System (INIS)
Shadow effect was used for investigating damage of uranium dioxide monocrystal. The dependence of shadow minimum parameters on fluence of "2"2Ne ions with 172 MeV energy was followed when detecting fission fragments. Ion dose responsible for sufficient microdamage of lattice structure, included into the classification of heavy ion damage effect on monocrystals was determined. The problem of radiation intensity effect on the character of occurred damages was studied. It was established that macroscopic sample failure, caused by generation of considerable mechanical stresses in monocrystal under beam effect could be observed along with microdamages of lattice structure at ion flux density >10"1"2 cm"-"2Xs"-"1.
Characterization of the combustion of biomass producer gas in a constant volume combustion bomb
British Library Electronic Table of Contents (United Kingdom)
In this article a methodology is presented for studying the influence of the biomass moisture content and the biomass/air ratio on the producer gas composition and on the chemiluminescent emissions during the combustion process. Firstly, a mathematical model based on the thermo-chemical processes inside the gasifier is used to predict the composition of the producer gas as a mixture of CO, CO2, H2, N2, CH4 and H2O gases. Secondly, the predicted composition is introduced into a constant volume combustion bomb (CVCB), which simulates the typical conditions inside the combustion chamber of an internal combustion engine, in order to characterize its combustion under gasoline-type conditions through the instantaneous pressure and the detection of the spontaneous luminous radiation (chemilumines...
2010-01-01
A mobile gamma scanning system for detecting radiation anomalies
Energy Technology Data Exchange (ETDEWEB)
A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A /sup 226/Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.
1983-09-01
A mobile gamma scanning system for detecting radiation anomalies
International Nuclear Information System (INIS)
A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A "2"2"6Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.
The effect of perinatal "6"0Co gamma radiation on brain weight in beagles
International Nuclear Information System (INIS)
Beagle dogs were given single, whole-body "6"0Co gamma-radiation exposures at one of three prenatal (8, 28, or 55 days postcoitus) or three postnatal (2, 70, or 365 days postpartum) ages to evaluate the relative radiosensitivity of various stages of brain development. A total of 387 dogs received mean doses ranging from 0.16 to 3.83 Gy, and 120 dogs were sham-irradiated. Groups of dogs were sacrificed at preselected times from 70 days to 11 years of age. Brain weight decreased significantly with increasing dose in dogs irradiated at 28 or 55 days postcoitus or at 2 days postpartum. Irradiations at 28 days postcoitus were dramatically more effective in causing a reduction in brain weight than those at 55 days postcoitus or 2 days postpartum. Among dogs given 1.0 Gy or more and followed for up to 4 years, there was a radiation effect evident at all three sensitive exposure ages. Among dogs given lower doses and followed for ...
Exposure of Finnish population to solar UV radiation and consequent carcinogenic effects
Energy Technology Data Exchange (ETDEWEB)
Depletion of stratospheric ozone increases irradiance of terrestrial ultraviolet (UV) radiation at short wavelengths, which may be harmful to the human health. To understand quantitatively the risks caused by increasing UV radiation to the Finnish population, the actual UV exposure of the population has to be assessed. It was shown that the snow reflection increases the UV exposure to the face and eyes particularly in the northern Finland. In 1993 exceptionally low ozone levels persisted up to the end of May, which resulted in a theoretical increase in the annual UV dose ranging from 8 % to 13 % in Finland. The maximal increase in the measured erythemally effective dose rate was 34 % on 23 April, when compared with the theoretical normal value. During this study exposure models have been developed. The models have been combined them with Green`s radiation transfer model to estimate annual facial UV ...
1996-12-31
Combined therapy of localized Ewing's sarcoma of bone: Analysis of results in 100 patients
International Nuclear Information System (INIS)
From 1979 to 1986, 182 patients with biopsy proven diagnosis of Ewing's sarcoma of bone were observed. One hundred of the 182 patients (72 males, 28 females, median age 15.8 years) with localized disease and no previous treatment were treated with chemotherapy (VCR, ADM, CTX, D-ACT) for 15-18 months. Local treatment was radiotherapy (42 patients), surgery (31 patients), or a combination of both (27 pts). Radiation doses ranged from 45 to 64 Gy given with conventional fractionation. Median follow-up was 51.2 months (24-106). Overall and disease-free survival were, respectively, 58.7 and 42.6%. Resected patients tended to have a better local control (Surgery 93.6%, Surgery + Radiation therapy 92.6%, Radiation therapy 69.1%). Disease-free survival was significantly related to the volume of the primary tumor (bulky: 33.2%, not-bulky: 57.7%), to site (extremities 54.6%, central sites 16.6%, other sites ...
International Nuclear Information System (INIS)
The distribution of radiation dose commitments within the body that can result from the lung deposition of a number of transuranic radionuclides ("2"3"7Pu, "2"3"8Pu, "2"3"9Pu, "2"4"0Pu, "2"4"1Pu, "2"4"2Pu, "2"4"3Pu, "2"4"4Pu, "2"4"1Am, "2"4"2Am, "2"4"3Am, "2"4"4Am, "2"4"2Cm, "2"4"3Cm, "2"4"4Cm, and "2"4"6Cm) was calculated. The variables that influence these organ dose commitments include the mobility of the particle or its dissolution products within the body, the radiation characteristics of the inhaled radionuclides and their progeny, and the size of the particles inhaled. In the calculation of organ dose commitments for whole-body, lungs, liver, bone tissues, kidneys, and gastrointestinal tract from the inhalation of transuranium radionuclides, physical characteristics of importance are the dimensions of the particle, its aerodynamic properties, and its density. For particles within the respirable size range, a useful ...
1975-11-17
International Nuclear Information System (INIS)
Irradiation of live bivalve molluscs is a promising new technique to reduce the public health threats of viral and bacterial pathogens in the consumption of raw shellfish. In studies conducted within the past year, live hardshelled clams and oysters were innoculated with Simian Rotavirus SA-11, Poliovirus I, and Hepatitis-A virus and treated with gamma ray ionizing radiation from University of Lowell/DOE 800,000 Curie "6"0Co source over a dose range of 0.5--10 kiloGray (50--1000 kilorad) to determine the effectiveness of the process in eliminating viral activity and thus easing the potential viral health threats associated with uncooked bivalves. Two viral strains, SA-11 and Poliovirus I, were employed as models to perfect laboratory technique and to estimate the most appropriate range of dose exposures necessary for optimal inactivation of the infectious pathogen, Hepatitis A. Post-irradiation survivorship of the oysters ...
Energy Technology Data Exchange (ETDEWEB)
A fast and simple flow-through optosensor was designed and characterized for the direct screening of four tetracycline (TCC) antibiotics (tetracycline, oxytetracycline, chlortetracycline and doxycycline) in water and bovine milk samples. The proposed optosensor provides rapid binary yes/no overall responses, being appropriate for the screening of this family of antibiotics above or below a pre-set concentration threshold. The experimental set-up is based on a flow-injection manifold coupled on-line to a phosphorescence detector. Aliquots of the samples are pretreated with Eu(III) to form room temperature phosphorescent metal chelates and injected in the flow manifold. Those chelates are then on-line retained on a conventional flow-cell (packed with polymeric Amberlite XAD-4 particles) which is placed inside the cell holder of the phosphorimeter. After the emission is registered, the antibiotic-metal complexes are eluted from the packed resin with 1 M HCl (for milk samples a second ...
2007-04-18
Ultrasensitive fluorescence detection of DNA
Progress on Ultrasensitive fluorescence detection of DNA is briefly described. (CBS)
1991-01-01
Fluorescent Silicate Materials for the Detection of Paraoxon
... significantly lower limits of detection. The complex fluorescence spectra of these constructs indicated that only a portion ...
2010-03-19
International Nuclear Information System (INIS)
To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI scanner (Magnetom Avanto, Siemens Medical Solutions) with a total field of view of ...
The Use of Medical Images in Planning and Delivery of Radiation Therapy
UK PubMed Central (United Kingdom)
Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available
1997-09-01
Animal Models for Radiation Injury, Protection and Therapy
... radiation during clinical therapy and exposures due to radiation accidents or attacks, in which the doses are uncontrolled ... only be used off-label in victims of radiation accidents or attacks. The idea...
International Nuclear Information System (INIS)
Naturally occurring radionuclides are present in most material. The most common naturally occurring radionuclides in material are those of the uranium and thorium series and potassium-40. This material is commonly referred to as Naturally Occurring Radioactive Material (NORM). In some material the levels of naturally occurring radionuclides are significantly higher, to the extent that regulatory control may be required for radiation protection purposes. Regulation of NORM presents a range of new challenges for both regulators and operators. Unlike more traditional industries dealing with radionuclides, NORM industries have generally not had any radiological oversight and, for example, are not equipped for radiological monitoring. Some consumer goods containing NORM, which have not traditionally been considered as a radiological problem (such as some fertilizers), may require regulation and this may have social and economic consequences. The ...
2002-09-23
Energy Technology Data Exchange (ETDEWEB)
Formaldehyde, a well-identified indoor pollutant, was recently classified as carcinogenic. New regulations for the air quality are expected and therefore there is a need for low-cost sensors, sensitive and selective with a fast response time for the detection of formaldehyde at ppb level. In the present work, we had developed a chemical sensor based on nano-porous matrices doped with Fluoral-P and optical methods of detection. The nano-porous matrices, elaborated via the Sol-Gel process, display nano-pores whose cavity is tailored for the trapping of the targeted pollutant. They provide a first selectivity with the discrimination of the pollutants by their size. A second selectivity is obtained with a molecular probe, Fluoral-P, which reacts specifically with formaldehyde leading to the 3,5- di-acetyl-1,4-dihydro-lutidine (DDL). The kinetics of formation of DDL was studied as function of many parameters such as the concentration of Fluoral-P in ...
2006-12-15
Experimental studies of compact real-time neutron dosimeters
International Nuclear Information System (INIS)
Full text: Semiconductor detectors coated with boron or lithium compounds have been studied for neutron detection for decades but, until recently, have been limited to thermal neutron detection efficiencies of less than 5%. We reported previously on development and simulation studies of perforated detectors whose perforations are filled with neutron-reactive material in order to produce higher detection efficiencies. Incorporation of bare and cadmium-backed detectors into battery-powered devices with low-power electronics enables us to produce compact personal neutron dosimeters that provide LED readout of counts, which can be related approximately to neutron dose. We report here on experimental studies with such compact devices; devices capable of direct readout in dose units are anticipated. The thermal and epithermal neutron flux densities from the tangential beam tube of the TRIGA Mark II reactor at Kansas State ...
2008-06-01
Energy Technology Data Exchange (ETDEWEB)
A small-sized inexpensive carbon dioxide gassensor was prepared using LiTi2 (PO4)3 +0.2Li3PO4 as lithium-ion conductive, solid electrolyte and its detectability and the effects of co-existing gases were examined. The above compound was obtained by the method where a powdery mixture of Li2CO3, TiO2, (NH4)H2PO4 and Li3PO3 was molded in the presence of a sintering assistant, subjected to hydrostatic press, and sintered. Measurements were made on the relation between CO2 concentration and the electromotive force of the CO2 sensor made of the compound and the influence of concentration of coexisting NO2, SO2 or CH4 on the electromotive force. The results are summarized as follows. A linear relation exists between the electromotive force and the CO2 concentration in the range from 80ppm to 1% to show a good agreement between theoretical and experimental results. Coexistence of NO2 the range of 100-4500ppm has no influence on the ...
1992-10-31
Topics in axion and neutrino physics, time reversal violation, and Higgs detection
Energy Technology Data Exchange (ETDEWEB)
A number of systems which can elucidate physics beyond the standard model are investigated. The production of axions by a network of cosmic strings in the early universe is calculated. This allows an upper bound to be placed on the axion decay constant, and provides the preferred Peccei-Quinn symmetry breaking scale for axions to make up the dark matter of the universe. Models of neutrino mass arising from strong interactions are investigated. These models possess a massless up quark, thereby solving the strong CP problem. A systematic analysis of the contributions to time reversal violating atomic and molecular electric dipole moments is presented. Specific contributions from the supersymmetric standard model are calculated. The contributions arising from the QCD vacuum angle are also discussed. Prospects for detecting the axion by its long range coherent force are related to measurable electron dipole moments. A method for measuring neutrino ...
1993-12-31
Topics in axion and neutrino physics, time reversal violation, and Higgs detection
International Nuclear Information System (INIS)
A number of systems which can elucidate physics beyond the standard model are investigated. The production of axions by a network of cosmic strings in the early universe is calculated. This allows an upper bound to be placed on the axion decay constant, and provides the preferred Peccei-Quinn symmetry breaking scale for axions to make up the dark matter of the universe. Models of neutrino mass arising from strong interactions are investigated. These models possess a massless up quark, thereby solving the strong CP problem. A systematic analysis of the contributions to time reversal violating atomic and molecular electric dipole moments is presented. Specific contributions from the supersymmetric standard model are calculated. The contributions arising from the QCD vacuum angle are also discussed. Prospects for detecting the axion by its long range coherent force are related to measurable electron dipole moments. A method for measuring neutrino ...
Rapid Responding Palladium-Silver Surface Modified Microsensor for Hydrogen
Most palladium thin film based hydrogen gas sensors have response and recovery times that are too long to make them useful in vehicular and stationary gas leak detection applications. In contrast, a palladium-silver thin film based microcantilever (MC) hydrogen gas microsensor is reported herein with near ideal response characteristics for use in these hydrogen economy related applications. Specifically, 3-10 second response and recovery times have been measured for these sensors in contrast to previous sensor response measurements of several to tens of minutes using Pd thin film and MC based sensing techniques. The much reduced response times observed in the present study are attributed to a wet chemical Pd-Ag thin film deposition technique and a gas conditioning protocol that produces a highly nanostructured, porous film that rapidly adsorbs and desorbs H2, allowing rapid equilibration with the H2 concentration in the surrounding air. The wet chemical process and ...
2010-01-01
Non-Detection of Polarized, Scattered Light from the HD 189733b Hot Jupiter
Using the POLISH instrument, I am unable to reproduce the large-amplitude polarimetric observations of Berdyugina et al. (2008) to the >99.99% confidence level. I observe no significant polarimetric variability in the HD 189733 system, and the upper limit to variability from the exoplanet is Delta_P < 7.9 x 10^(-5) with 99% confidence in the 400 nm to 675 nm wavelength range. Berdyugina et al. (2008) report polarized, scattered light from the atmosphere of the HD 189733b hot Jupiter with an amplitude of two parts in 10^4. Such a large amplitude is over an order of magnitude larger than expected given a geometric albedo similar to other hot Jupiters. However, my non-detection of polarimetric variability phase-locked to the orbital period of the exoplanet, and the lack of any significant variability, shows that the polarimetric modulation reported by Berdyugina et al. (2008) cannot be due to the exoplanet.
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
Trichlorfon is an organophosphorus insecticide, which is extensively being used for protection of fruit crops. Trichlorfon is a thermal labile compound, which cannot be easily determined by gas chromatography (GC) and has no suitable group for sensitive detection by high performance liquid chromatography (HPLC). In this study, a {sup 31}P nuclear magnetic resonance ({sup 31}P NMR) has been described for monitoring of trichlorfon without any separation step. The quantitative works of {sup 31}P NMR spectroscopy has been performed in the presence of an internal standard (hexamethylphosphoramide). Limit of detection (LOD) for this method has been found to be 55 mg L{sup -1}, without any sample preparation, and the linear working range was 150-5500 mg L{sup -1}. Relative standard deviation (R.S.D.%) of the method for three replicates within and between days was obtained {<=}9%. The average recovery efficiency was ...
2006-08-25
International Nuclear Information System (INIS)
Sonography, subtraction scintigraphy, computed tomography and MRI were compared in 100 patients who had surgery 105 times for hyperparathyroidism (HPT). Surgical and pathological data were available for all operations. A total of 105 MR, 77 CT, 84 sonograms and 70 subtraction scintigrams were performed. The ability of the imaging modalities, individually and in combination, to detect HPT, histology, size, concomitant thyroid disease and location of the diseased glands has been evaluated. For primary HPT, sensitivity ranged from 68% for MRI to 40% for scintigraphy but was much lower for tertiary HPT with all modalities. The ability to identify diseased glands was strongly size dependent for all methods. If patients had had previous neck surgery, the most sensitive methods were MRI and scintigraphy and this also held true for patients with concomitant thyroid disease and ectopically located glands. The findings presented suggest that while ...
Fire detection for conveyor-belt entries. Rept. of Investigations/1991
Energy Technology Data Exchange (ETDEWEB)
The report details the results of a series of large-scale experiments where small coal fires were used to ignite conveyor belting at air velocities ranging from 0.76 m/s to 6.1 m/s. In the tests, electrical strip heaters imbedded within a pile of coal were used to heat the coal to a point of flaming ignition. The flaming coal subsequently ignited conveyor belting located approximately 5 to 10 cm above the coal pile. During the tests, temperature, CO, and smoke levels were continuously measured in order to determine both alarm time and level as the fire intensity progressed through the stages of smoldering coal, flame coal, and flaming coal plus flaming belt. Analysis of the data leads to certain conditions of air velocity and sensor alarm levels that are required for early detection of conveyor belt entry fires. Two nomographs are presented which define sensor alarm levels and sensor spacings as a function of belt entry cross-sectional area and ...
1991-01-01
European multicentre evaluation of the Super Aution SA-4220 urinalysis analyser.
A multicentre evaluation of the urine test strip analyser Super Aution-4220 was carried out in six laboratories. The analytical performance of the instrument with regard to imprecision, linearity, detection limit, drift, carry-over and method comparison was studied. Using the Aution stick 8 test strip the pH, glucose, protein, ketones, bilirubin, blood, urobilinogen and leukocyte esterase were analysed. Specific gravity measurements were performed by refractive index method. Within-run and between-run imprecision determined at three levels of analyte were good. No carry-over was observed. Obtained results were linear through all the described analytical range. No significant drift was detected. Method comparison with some quantitative methods was performed and showed a good correlation with most of the analytes. The study of interferences showed minor interferences by common therapeutic drugs with the measurement of some ...
1998-12-01
International Nuclear Information System (INIS)
Direct electrochemistry and electrocatalysis of catalase (Cat) was studied based on a nano-composite film consisting of amine functionalized graphene and gold nanoparticles (AuNPs) modified glassy carbon electrode. Graphene was synthesized chemically by Hummers and Offeman method and then was functionalized with amino groups via chemical modification of carboxyl groups introduced on the graphene surface. The nano-composite film showed an obvious promotion of the direct electron transfer between Cat and the underlying electrode, which attributed to the synergistic effect of graphene-NH2 and AuNPs. The resultant bioelectrode retained its biocatalytic activity and offered fast and sensitive H2O2 quantification. Under the optimized experimental conditions, hydrogen peroxide was detected in the concentration range from 0.3 to 600 ?M with a detection limit of 50 nM at S/N = 3. The biosensor exhibited some advantages, such as ...
2011-02-28
Energy Technology Data Exchange (ETDEWEB)
A procedure for the determination of carboxylic acids (benzoic and C{sub 8}-C{sub 16} aliphatic acids) in oxidised engine oils is described. It is based on a simple and selective derivatisation of the acids with a fluorescent label 9-anthracene-methanol followed by reverse-phase separation on an ODS column with a water-acetonitrile-tetrahydrofuran (20:40:40 by volume) mobile phase and post-column reaction with bis(2,4-dinitrophenyl) oxalate and hydrogen peroxide. The chemiluminiscence emission from the reaction was monitored using a lamina flow-through detector. Analysis of oxidised oils showed that although there was quenching of chemiluminiscence emission by the oil matrix, the acids could be determined over the range 0-0.4% (m/v) in the oil with a detection limit of 0.013% (m/v) (130 pmol on-column with a 20 {mu}l injection) for lauric acid. 8 figs., 2 tabs., 17 refs.
1992-09-01
Energy Technology Data Exchange (ETDEWEB)
Twenty children with respiratory disease ingested 500 ..mu..Ci of Tc-99m sulfur colloid orally, and scintigrams of the thorax were obtained to determine whether pulmonaryaspiration of gastric contents could be detected. The children ranged in age from 1 mo to 14 y; 13 were 8 months of age or younger. Children were studied at 5 min and 4 h after ingestion of Tc-99m sulfur colloid using a high-sensitivity computer oscilloscope to record 100K-count images. Additional images were obtained after the children had slept overnight. Five children (25%) showed definite pulmonary accumulation of activity; four of these also had a barium swallow and three showed either pulmonary aspiration of barium or moderately severe gastroesophageal reflux. Oral ingestion of Tc-99m sulfur colloid provides a noninvasive means for diagnosing pulmonary aspiration under physiologic conditions in infants and children.
1980-04-01
Energy Technology Data Exchange (ETDEWEB)
We have examined the detection by a /sup 125/I-labeled basic protein, cationized cytochrome c, of selected proteoglycans (PGs) and standard preparations of glycosaminoglycans (GAGs) immobilized on Nylon 66 and also on positively charged Nylon 66. Immobilization on Nylon 66 appears to allow a relative freedom of interaction between PGs or GAGs and /sup 125/I-cationized cytochrome c, but a more restricted reaction was observed when PGs and GAGs were immobilized to positively charged Nylon 66. On this support PGs with large numbers of GAG side chains reacted well with /sup 125/I-cationized cytochrome c, but GAGs were minimally reactive. By taking advantage of some of the properties of large-pore agarose-acrylamide gels, rapid partial characterization of some PGs can be accomplished in the 10-ng range, and therefore at a sensitivity equal to PGs with internal biosynthetic labels.
1987-09-01
International Nuclear Information System (INIS)
Electron probe microanalysis (EPMA) offers high sensitivity and high accuracy in quantitative measurements of chemical compositions and mass coverages. Owing to the low detection limits of the wavelength-dispersive technique, monolayers with mass coverages of about 0.05 pg cm z can be detected. Assuming a density of 5 g cm--3 this corresponds to a thickness of 0.1 nm. With these advantages in mind, EPMA was extended to depth profile analysis in the sub-micron range using a surface removal technique. The present paper shows how depth profile analysis can be improved by combining EPMA and the focused ion beam (FIB) technique. The focused ion beam system uses a Ga+ ion beam. The ion beam allows the milling of defined geometries on the nanometer scale, so that very shallow bevels with exactly defined angles in relation to the surface can be obtained. Low surface damage is expected due to low sputtering effects. Calibrated WDX ...
Energy Technology Data Exchange (ETDEWEB)
Yet designed to measure charged component of the cosmic rays, the foreseen Alpha Magnetic Spectrometer (AMS-02) could also release {gamma}-ray studies, in the energy range from GeV to TeV, using the tracker system, for {gamma}-rays converted in e{sup +}e{sup -} pair, and the electromagnetic calorimeter. In the first part of the thesis are described the calibrations and the performances of the engineering model of the calorimeter, obtained from the analysis of data taken during a test-beam performed at CERN in July 2002. In the second part of the thesis, the AMS-02 discovery potential for {gamma}-astrophysics is presented. While exposure maps of the {gamma}--sky are computed for one year of data taking with the {gamma}--detectors, the acceptance of the calorimeter is obtained from Monte-Carlo simulations. The AMS-02 potential is then estimated for signals from the Vela pulsar and for some supersymmetric signals from the Galactic Center. (author)
2004-12-15
Characterization of the heterokaryotic and vegetative diploid phases of Magnaporthe grisea
Energy Technology Data Exchange (ETDEWEB)
The heterokaryotic and vegetative diploid phases of Magnaporthe grisea, a fungal pathogen of grasses, have been characterized. Hyphal tip cells and conidia (vegetative spores) taken from these heterokaryons are auxotrophs with phenotypes identical to one or the other of the parents. M. grisea heterokaryons have completely septate hyphae with a single nucleus per cell. Heterokaryons have been utilized for complementation and dominance testing of mutations that affect nutritional characteristics of the fungus. Heterokaryons growing on minimal medium spontaneously give rise to fast-growing sectors that have the genetic properties expected of unstable heterozygous diploids. In fast-growing sectors, most hyphal tip cells are unstable prototrophs. The conidia collected from fast-growing sectors include stable and unstable prototrophs, as well as auxotrophs that exhibit a wide range of phenotypes, including many recombinant classes. Genetic linkage in meiosis has been ...
1984-01-01
Energy Technology Data Exchange (ETDEWEB)
A novel composite film, comprising of hydrophobic ionic liquid (IL), multi-walled carbon nanotubes (MWNTs) and gold nanoparticles (GNP), was fabricated and characterized. The GNP was introduced through electrochemical deposition on IL-MWNT gel film coated glassy carbon electrodes (GCE). Experiments showed that both IL and MWNTs could facilitate the GNP deposition. With GNP the composite film exhibited smaller electron transfer resistance and higher sensitivity in sensing guanine (G) and adenine (A). Under the optimized experimental conditions, the anodic peak currents were linear to the analyte concentration in the ranges of 0.008-2.0 {mu}M. The detection limits were down to nanomole level after an accumulation of 150 s on open-circuit. In addition, on the composite film coated GCE, the anodic peaks of G and A were well separated, and their response sensitivities kept almost unchanged no matter whether they coexisted or not. This proposed ...
2008-11-01
International Nuclear Information System (INIS)
A novel composite film, comprising of hydrophobic ionic liquid (IL), multi-walled carbon nanotubes (MWNTs) and gold nanoparticles (GNP), was fabricated and characterized. The GNP was introduced through electrochemical deposition on IL-MWNT gel film coated glassy carbon electrodes (GCE). Experiments showed that both IL and MWNTs could facilitate the GNP deposition. With GNP the composite film exhibited smaller electron transfer resistance and higher sensitivity in sensing guanine (G) and adenine (A). Under the optimized experimental conditions, the anodic peak currents were linear to the analyte concentration in the ranges of 0.008-2.0 ?M. The detection limits were down to nanomole level after an accumulation of 150 s on open-circuit. In addition, on the composite film coated GCE, the anodic peaks of G and A were well separated, and their response sensitivities kept almost unchanged no matter whether they coexisted or not. This proposed ...
2008-11-01
Chandra Observations of Nuclear X-ray Emission from a Sample of Radio Sources
We present the X-ray properties of a sample of 17 radio sources observed with the Chandra X-ray Observatory as part of a project aimed at studying the X-ray emission from their radio jets. In this paper, we concentrate on the X-ray properties of the unresolved cores. The sample includes 16 quasars (11 core-dominated and 5 lobe-dominated) in the redshift range z=0.30--1.96, and one low-power radio-galaxy at z=0.064. No diffuse X-ray emission is present around the cores of the quasars, except for the nearby low-power galaxy that has diffuse emission on a scale and with a luminosity consistent with other FRIs. No high-amplitude, short-term variability is detected within the relatively short Chandra exposures. However, 1510-089 shows low-amplitude flux changes with a timescale of $\\sim$25 minutes. The X-ray spectra of the quasar cores are generally well described by a single power law model with Galactic absorption. However, in six quasars we find ...
2003-01-01
Analysis of pesticides in dried hops by liquid chromatography-tandem mass spectrometry.
An analytical method was developed for the determination of eleven agrochemicals [abamectin (as B1a), bifenazate, bifenthrin, carfentrazone-ethyl, cymoxanil, hexythiazox, imidacloprid, mefenoxam, pymetrozine, quinoxyfen, and trifloxystrobin] in dried hops. The method utilized polymeric and NH2 solid phase extraction (SPE) column cleanups and liquid chromatography with mass spectrometry (LC-MS/MS). Method validation and concurrent recoveries from untreated dried hops ranged from 71 to 126% for all compounds over three levels of fortification (0.10, 1.0, and 10.0 ppm). Commercially grown hop samples collected from several field sites had detectable residues of bifenazate, bifenthrin, hexythiazox, and quinoxyfen. The control sample used was free of contamination below the 0.050 ppm level for all agrochemicals of interest. The limit of quantitation and limit of detection for all compounds were 0.10 and 0.050 ppm, respectively. ...
2008-07-02
Energy Technology Data Exchange (ETDEWEB)
A Bragg curve counter equipped with an internal production target was developed for the measurements of double-differential cross-sections of fragment production induced by neutrons at energies of tens of MeV. The internal target permitted a large detection solid angle and thus the registration of processes at low production rates. In this specific geometry, the detection solid angle depends on the emission angle and the range of the particle. Therefore the energy, atomic number, and angle of trajectory of the particle have to be taken into account for the determination of the solid angle. For the selection of events with tracks confined within a defined cylindrical volume around the detector axis, a segmented anode was applied. The double-differential cross-sections for neutron-induced production of lithium, beryllium, and boron fragments from a carbon target were measured at 0 deg. for 65 MeV neutrons. The results are in ...
2009-11-11
Replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory
Energy Technology Data Exchange (ETDEWEB)
The DOE-Idaho Operations Office (DOE-ID) has prepared an environmental assessment (EA) on the replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory at the Idaho National Engineering Laboratory (INEL). The purpose of this project is to replace the existing Health Physics Instrumentation Laboratory (HPIL) with a new facility to provide a safe environment for maintaining and calibrating radiation detection instruments used at the Idaho National Engineering Laboratory. The existing HPIL facility provides portable health physics monitoring instrumentation and direct reading dosimetry procurement, maintenance and calibration of radiation detection instruments, and research and development support-services to the INEL and others. However, the existing facility was not originally designed for laboratory activities and does not provide an adequate, safe environment ...
1995-05-01
Energy Technology Data Exchange (ETDEWEB)
A method for detecting electrons emitted as secondary particles by photon incidence to a specimen, as well as a method of using the photons emitted by electron incidence as detecting particles are explained. Pd-Si(100)2{times}1 system is adopted for a case study of using photo-electron spectroscopy where synchrotron emitted light in soft X-ray region is used as the incident light. Pd atoms are deposited little by little on clean Si surface to investigate the electron structure of the surface, and the interface electron structure after bonded formation of Pd(thin film)-Si(substrate) is estimated. Radiation soft X-ray spectroscopy is employed to observe the real state of the bonded interface of Pd(thin film)-Si(substrate) prepared by depositing Pd film in a short period of time. In the case of radiation soft X-ray spectroscopy with electron beam excitation, bonded system of thin film and substrate can be ...
1995-07-20
Energy Technology Data Exchange (ETDEWEB)
We present a collisional-radiative approach of the theoretical analysis of laser-induced breakdown spectroscopy (LIBS) plasmas. This model, which relies on an optimized effective potential atomic structure code, was used to simulate a pure aluminum plasma. The description of aluminum involved a set of 220 atomic levels representative of three different stages of ionization (Al{sup 0}, Al{sup +} and Al{sup ++}). The calculations were carried for stationary plasmas, with input parameters (n{sub e} and T{sub e}) ranging respectively between 10{sup 13-18} cm{sup -3} and 0.3-2 eV. A comparison of our atomic data with some existing databases is made. The code was mainly developed to address the validity of the local thermodynamic equilibrium (LTE) assumption. For usual LIBS plasma parameters, we did not reveal a sizeable discrepancy of the radiative equilibrium of the plasma towards LTE. For cases where LTE was firmly believed to ...
2009-10-15
International Nuclear Information System (INIS)
We present a collisional-radiative approach of the theoretical analysis of laser-induced breakdown spectroscopy (LIBS) plasmas. This model, which relies on an optimized effective potential atomic structure code, was used to simulate a pure aluminum plasma. The description of aluminum involved a set of 220 atomic levels representative of three different stages of ionization (Al0, Al+ and Al++). The calculations were carried for stationary plasmas, with input parameters (ne and Te) ranging respectively between 1013-18 cm-3 and 0.3-2 eV. A comparison of our atomic data with some existing databases is made. The code was mainly developed to address the validity of the local thermodynamic equilibrium (LTE) assumption. For usual LIBS plasma parameters, we did not reveal a sizeable discrepancy of the radiative equilibrium of the plasma towards LTE. For cases where LTE was firmly believed to stand, the Boltzmann plot outputs of this ...
2009-10-01
International Nuclear Information System (INIS)
An attempt was made for early quantitative assessment of the severety of an injury, using the nuclear acids (NA) content as a biochemical indicator. Sexually mature male rats with body mass 160-180 g were irradiated with doses 0.5, 1, 2, 4 and 8 Gy of "1"3"7Cs source. Uneven irradiation was achieved by shielding the abdominal-lumbar area with lead rings, measuring 2,5/50 mm. A 28-30% fall of the dose beneath the shielded zone was thus provided. Dose-dependent quantitative changes in Na content were determined on hours 24 and 72 within the range from 0.5 to 8 Gy and followed up until day 30 after irradiation with nonlethal (2 Gy) and lethal (8 Gy) doses. The total NA content in the leucocytes was determined by the method of Kritski and Aleksandrov. The uneven irradiation of rats within the 0,5-8 Gy range induced early dose-dependent changes in NA content. The nature of their post-irradiation dynamics also depended on the ...
International Nuclear Information System (INIS)
A post-irradiation annealing study was conducted with use of reactor pressure vessel(RPV) steel A533B C1.1 base metal irradiated to a dose of 4.84x10"1"8 n/cm"2 at about 380 deg C. Microhardness and positron annihilation (PA) methods were used to obtain better understanding of the recovery of radiation hardening. Isochronal anneal experiments indicated that two recovery processes occur during annealing of irradiated specimens. The first recovery process occurs in the temperature of 280-305 deg C. The variations of Ip, Iw and R parameters indicated that the formation of vacancy clusters by vacancy aggromeration and the annihilation parameters measured indicated that the dissolution of carbon atoms decorated around vacancy-type defects and possible precipitates, and the annihilation of monovacancies give rise to the second recovery process. It was further indicated that radiation anneal hardening (RAH) in the range of 305-405 ...
Uranium isotopic assay instrument
International Nuclear Information System (INIS)
Full text: The isotopic assay instrument under development at Pacific Northwest National Laboratory (PNNL) is capable of rapid prescreening to detect small and rare particles containing high concentrations of uranium in a heterogeneous sample. The isotopic measurement concept is based on laser vaporization of solid samples followed by sensitive isotope-specific detection using either uranium atomic fluorescence emission or uranium atomic absorbance. Both isotopes are measured concurrently, following a single ablation laser pulse using two external-cavity violet diode lasers. The simultaneous measurement of both isotopes enables the correlation of the fluorescence and absorbance signals on a shot-to-shot basis. This measurement approach demonstrated negligible channel crosstalk between isotopes. Scanning the heterogeneous samples provides high-resolution imagery of sample isotopic fluorescence and absorbance. Isotopically selective excitation of ...
2006-10-16
Monitoring of DNA and cytogenetic damage in lymphocytes from persons with skin cancer diseases
International Nuclear Information System (INIS)
There is a lot of interest in the studies that would help to understand whether there is a casual association between cancer and various types of molecular or cytogenetic damage detected in human cells. One major oncogenesis process is activation of proto-oncogenes by point mutations or chromosomal translocation. There are substantial evidence that indicates that the loss of heterozygosity of certain chromosomes is involved in human cancerogenesis. Our study aimed to elicit the possible association between cancer and DNA and cytogenetic abnormalities induced in lymphocytes of people bearing various categories of skin cancer cells. Fresh blood was collected by venipuncture from 25 individuals (including nine prior to cancer treatment). All patients were nonsmoking males, however 42.3 % of them were former smokers. Blood samples were divided into two parts and in the first part of samples cytogenetic studies were performed immediately, while from the second part ...
2004-11-01
Energy Technology Data Exchange (ETDEWEB)
The overall goal of the proposed project is to explore the use of partitioning tracers to characterize dense nonaqueous phase liquids (DNAPLs) in aquifer systems. Bulk-phase partitioning tracers will be investigated to detect and determine DNAPL saturation, while interface partitioning tracers will be investigated to measure the area of the DNAPL-water interface. The specific objectives that will be addressed to accomplish this goal are: (1) Investigate the use of partitioning tracers to detect and determine both the saturation and interfacial area of DNAPLs in saturated porous media. (2) Investigate the effect of rate-limited mass transfer on the transport behavior of partitioning tracers. (3) Investigate the effect of porous-media heterogeneity on the transport behavior of partitioning tracers. (4) Develop and evaluate mathematical models capable of simulating the transport of partitioning tracers in complex systems. This proposal outlines an ...
2000-09-14
International Nuclear Information System (INIS)
Computed tomography would be a better method to detect and characterize a Thorotrast-induced liver tumour. The selective opacification of the RES by Thorotrast creates an intrinsic opacification of the liver similar in effect to contrast agents being evaluated for liver CT, such as ethoioidized oil emulsion. The computed tomographic appearance of Thorotrast-associated cholangiocarcinoma is usually a large, inhomogenous mass composed of disordered area of tissue of high density due to Thorotrast deposits, and of very low density. Thorotrast-induced cholangiocarcinoma originates in the peripheral biliary tree suprounding the highest mean concentration of Thorotrast deposition, so that visible soft tissue masses in the higher density spots in the liver are not produced in the early stage. The tendency for the opacity of the liver to decrease slowly with time and result in an uneven trabeculation and high density spots suggests that small tumors may be difficult to ...
Repeat Stereotactic Radiosurgery for Acoustic Neuromas
International Nuclear Information System (INIS)
Purpose: To evaluate the outcome of repeat stereotactic radiosurgery (SRS) for acoustic neuromas, we assessed tumor control, clinical outcomes, and the risk of adverse radiation effects in patients whose tumors progressed after initial management. Methods and Materials: During a 21-year experience at our center, 1,352 patients underwent SRS as management for their acoustic neuromas. We retrospectively identified 6 patients who underwent SRS twice for the same tumor. The median patient age was 47 years (range, 35-71 years). All patients had imaging evidence of tumor progression despite initial SRS. One patient also had incomplete surgical resection after initial SRS. All patients were deaf at the time of the second SRS. The median radiosurgery target volume at the time of the initial SRS was 0.5 cc and was 2.1 cc at the time of the second SRS. The median margin dose at the time of the initial SRS was 13 Gy and was 11 Gy at the time of the second ...
2010-02-01
Vertical array receptions of the Heard Island transmissions
Energy Technology Data Exchange (ETDEWEB)
The Heard Island Feasibility Test (HIFT) demonstrated that coded acoustic signals could be detected at ranges up to 18,000 km with currently available source technology. This paper describes one component of the HIFT where a large aperture vertical line array was deployed to record the signals transmitted from Heard Island. We have performed four analysis Of the VLA receptions, of the Heard Island signals. All four suggest the presence of higher order modes. The frequency- vertical wavenumber analysis and the modal beamforming indicate that mode 3 has the highest amplitude while the modal fitting suggests that made 5--6 are largest. It is difficult to resolve the differences since the SNR at the VLA, nearly 18,000 km with a transmission loss of around 145 dB, is quite low. Individual arrivals could not be distinguished because of the long integration time necessitated by the low SNR.
1993-03-23
Use of a tethersonde measurement system to conduct a Doppler SODAR performance audit
Energy Technology Data Exchange (ETDEWEB)
With the increased usage of dispersion models that require stack top wind information, such as the Complex Terrain Dispersion Model (CTDM), the need for a reliable method to collect elevated wind data has also increased. Doppler Sound Detection and Ranging (SODAR) instruments have gained recognition as a viable means of collecting such data. SODAR technology has improved greatly over the last decade and is now a cost effective alternative to tall meteorological towers. SODARs are remote sensing devices that sample the atmosphere and calculate wind speed and wind direction data at different altitudes. This is accomplished by measuring the doppler shift of an acoustic pulse emitted by a ground level antenna.
1994-12-31
Thermoelectrically cooled water trap
Energy Technology Data Exchange (ETDEWEB)
A water trap system based on a thermoelectric cooling device is employed to remove a major fraction of the water from air samples, prior to analysis of these samples for chemical composition, by a variety of analytical techniques where water vapor interferes with the measurement process. These analytical techniques include infrared spectroscopy, mass spectrometry, ion mobility spectrometry and gas chromatography. The thermoelectric system for trapping water present in air samples can substantially improve detection sensitivity in these analytical techniques when it is necessary to measure trace analytes with concentrations in the ppm (parts per million) or ppb (parts per billion) partial pressure range. The thermoelectric trap design is compact and amenable to use in a portable gas monitoring instrumentation.
2006-02-21
International Nuclear Information System (INIS)
The extraction of Am(III) and Eu(III) has been investigated using mixtures of synthesized aromatic dithiophosphinic acids (R_2PSSH) and tributylphosphate (TBP), trioctylphosphine oxide (TOPO) or tributylphosphine oxide (TBPO) in toluene from nitric acid (0.01-1.5 mol l"-"1). There was no detectable extraction when R_2PSSHs were used alone as extractants for either Am(III) or Eu(III) (D_A_m_,_E_u<10"-"4) under the experimental conditions used in this study. High separation factors (D_A_m/D_E_u>20) with D_A_m>1 were achieved in the nitric acid range 0.1-1 moll"-"1 by means of a synergistic mixture of bischlorodithiophosphinic acid with TBP, TOPO or TBPO. (orig.)
1998-06-12
The propagation of relativistic heavy ions in multielement beam lines.
We describe calculations of the energy loss, range, stopping power, multiple scattering, and other related properties of a high-energy heavy-ion beam at any one of a set of beam line elements. A beam line element (e.g., any beam modification, detection, or control device) is characterized by its thickness, areal density, aperture, and function. The loss of multiply scattered particles to any finite-aperture detector is calculated in the small-angle approximation, and the position of the Bragg peak, as given by particles stopping in the second of two ionization chambers used for Bragg curve measurements, is estimated. A general purpose computer program, PROPAGATE, has been written to allow addition, deletion, and modification of the beam line elements used in the calculation and to provide a convenient means of repeating such calculations for arbitrary beam lines. Calculations and experimental measurements are compared and found to be in ...
Studies of basic parameters of electron-counting detection
International Nuclear Information System (INIS)
Measurements have been made of certain parameters relevant to the operation of electron-counting detectors. An experimental chamber consisting of a uniform-field drift tube and a coaxial proportional counter thas been employed to obtain data, at very low drift fields (E/p<0.02 V/cm Torr), on electron mobility and lifetimes in a range of gas mixtures. These mixtures included argon, methane, nitrogen and carbon dioxide. Measurements of single-electron spectra showed that, unexpectedly for the standard gas mixtures employed, useful departure from an exponential spectrum was not possible without the production of cathode secondaries. Although the present studies employed only the counter electrical signal the information obtained should be directly relevant to the operation of practical light-pulse systems. Examples of electron-counting spectra for soft X-rays are shown. (orig.).
1990-05-21
British Library Electronic Table of Contents (United Kingdom)
Various pyranocoumarins, calophyllolide, inophyllums B, C, G1, G2 and P, from Calophyllum inophyllum (Clusiaceae) leaves of French Polynesia (Austral, Marquesas, Society and Tuamotu archipelagos) have been determined in 136 leaf extracts using a high pressure liquid chromatography-UV-diode array detection (HPLC-UV-DAD) technique. Results show a wide range in chemical composition within trees growing on eighteen islands. The use of multivariate statistical analyses (PCA) shows geographical distribution of inophyllums and indicate those rich in HIV-1 active (+)-inophyllums. Inophyllum B and P contents (0.0-39.0 and 0.0-21.8mgkg-1, respectively) confirm the chemodiversity of this species within the large area of French Polynesia. The study suggests the presence of interesting chemotypes which...
2008-01-01
Reborn quadrant anode image sensor
International Nuclear Information System (INIS)
We describe a position sensitive photon counting microchannel plate based detector with an improved quadrant anode (QA) readout system. The technique relies on a combination of the four planar elements pattern and an additional fifth electrode. The charge cloud induced by single particle detection is split between the electrodes. The measured charge values uniquely define the position of the initial event. QA has been first published in 1976 by Lampton and Malina. This anode configuration was undeservedly forgotten and its potential has been hardly underestimated. The presented approach extends the operating spatial range to the whole sensitive area of the microchannel plate surface and demonstrates good linearity over the field of view. Therefore, the novel image sensor results in spatial resolution better then 50?m and count rates up to one million events per second.
2009-06-01
Reborn quadrant anode image sensor
British Library Electronic Table of Contents (United Kingdom)
We describe a position sensitive photon counting microchannel plate based detector with an improved quadrant anode (QA) readout system. The technique relies on a combination of the four planar elements pattern and an additional fifth electrode. The charge cloud induced by single particle detection is split between the electrodes. The measured charge values uniquely define the position of the initial event. QA has been first published in 1976 by Lampton and Malina. This anode configuration was undeservedly forgotten and its potential has been hardly underestimated. The presented approach extends the operating spatial range to the whole sensitive area of the microchannel plate surface and demonstrates good linearity over the field of view. Therefore, the novel image sensor results in spatial...
2009-01-01
British Library Electronic Table of Contents (United Kingdom)
The Pacific white shrimp, Litopenaeus vannamei, is the most important shrimp species in volume in world aquaculture. However, in recent decades, outbreaks of diseases, especially viral diseases, have led to significant economic losses, threatening the sustainability of shrimp farming worldwide. In 2004, Brazilian shrimp farming was seriously affected by a new disease caused by the Infectious myonecrosis virus (IMNV). Thus, disease control based on rapid and sensitive pathogen detection methods has become a priority. In this study, a specific quantitation method for IMNV was developed using real-time PCR with SYBR Green chemistry and viral load of the principal target tissues of chronically infected animals was quantified. The quantitative analysis revealed that mean viral load ranged from ...
2011-01-01
Precise Determination of the Neutron Magnetic Form Factor to Higher Q{sup 2}
Energy Technology Data Exchange (ETDEWEB)
The neutron elastic magnetic form factor G{sub M}{sup n} has been extracted from quasielastic scattering from deuterium in the CEBAF Large Acceptance Spectrometer, CLAS [B. Mecking et al., Nucl. Inst. and Meth. A 503 (2003) 513]. The kinematic coverage of the measurement is continuous over a broad range, extending from below 1 GeV{sup 2} to nearly 5 GeV{sup 2} in four-momentum transfer squared. High precision is achieved by employing a ratio technique in which most uncertainties cancel, and by a simultaneous in-situ calibration of the neutron detection efficiency, the largest correction to the data. Preliminary results are shown with statistical errors only.
2005-06-13
Precise Determination of the Neutron Magnetic Form Factor to Higher Q"2
International Nuclear Information System (INIS)
The neutron elastic magnetic form factor G_M"n has been extracted from quasielastic scattering from deuterium in the CEBAF Large Acceptance Spectrometer, CLAS [B. Mecking et al., Nucl. Inst. and Meth. A 503 (2003) 513]. The kinematic coverage of the measurement is continuous over a broad range, extending from below 1 GeV"2 to nearly 5 GeV"2 in four-momentum transfer squared. High precision is achieved by employing a ratio technique in which most uncertainties cancel, and by a simultaneous in-situ calibration of the neutron detection efficiency, the largest correction to the data. Preliminary results are shown with statistical errors only.
2005-06-13
Energy Technology Data Exchange (ETDEWEB)
To measure electron reactions on a picosecond timescale the investigators developed a picosecond pulse-conductivity technique, which makes use of the electron fine-structure pulses of our LINAC (pulse width 25 vs FWHM) to produce excess electrons and now detects changes in sample conductance under optimum conditions with an instrumental response of 18 ps. This resolution is in agreement with a theoretical estimate. This technique has been successfully applied to study excess electron reactions in solvents covering a mobility range from 0.24 to 100 cm/sup 2/V/sup -1/s/sup -1/; extension to lower mobility liquids seem possible.
1983-01-01
Observation of dust stream formation produced by low current, high voltage cathode spots
International Nuclear Information System (INIS)
Macroparticle acceleration driven by low current, high voltage cathode spots has been investigated for potential applications ranging from micrometeoroid simulation to nanoparticle deposition/implantation. Acceleration by this process was observed to occur when nanometer and micrometer-sized particles were exposed to a high voltage pulse in the presence of a plasma discharge. The applied negative voltage pulse initiates the formation of multiple, high voltage, low current cathode spots which provide the mechanism of actual acceleration of the charged dust particles. Dust streams generated by this process were detected using laser scattering techniques. Cathode spot behavior was also documented. The particle impact craters observed at the surface of downstream witness badges were documented using scanning electron microscopy and light microscopy. The observed impacts suggest the presence of energetic macroparticles formed during this process.
2004-04-01
Neutron-induced fission cross-section of {sup 233}U in the energy range 0.5<E{sub n}< 20 MeV
Energy Technology Data Exchange (ETDEWEB)
The neutron-induced fission cross-section of {sup 233}U has been measured at the CERN n-TOF facility relative to the standard fission cross-section of {sup 235}U between 0.5 and 20MeV. The experiment was performed with a fast ionization chamber for the detection of the fission fragments and to discriminate against {alpha} -particles from the natural radioactivity of the samples. The high instantaneous flux and the low background of the n-TOF facility result in data with uncertainties of {approx} 3%, which were found in good agreement with previous experiments. The high quality of the present results allows to improve the evaluation of the {sup 233}U (n,f) cross-section and, consequently, the design of energy systems based on the Th/U cycle. (orig.)
2011-01-15
Multifractal Fourier detrended cross-correlation analysis of traffic signals
Multifractal detrended cross-correlation analysis (MF-DXA) has been developed to detect the long-range power-law cross-correlation of considered signals in the presence of non-stationarity. However, crossovers arising from extrinsic periodic trends make the scaling behavior difficult to analyze. We introduce a Fourier filtering method to eliminate the trend effects and systematically investigate the multifractal cross-correlation of simulated and real traffic signals. The crossover locations are found approximately corresponding to the periods of underlying trend. Traffic velocity on one road and flows on adjacent roads show strong cross-correlation. They also present weak multifractality after periodic trends are removed. The traffic velocity and flow are cross-correlated in opposite directions which is accordant to their actual evolution.
2011-10-01
Energy Technology Data Exchange (ETDEWEB)
The Mississippi Office of Geology has conducted field trials using the surface exploration techniques of geomicrobial, radiometrics, and free soil gas. The objective of these trials is to determine if Mississippi oil and gas fields have surface hydrocarbon expression resulting from vertical microseepage migration. Six fields have been surveyed ranging in depth from 3,330 ft to 18,500 ft. The fields differ in trapping styles and hydrocarbon type. The results so far indicate that these fields do have a surface expression and that geomicrobial analysis as well as radiometrics and free soil gas can detect hydrocarbon microseepage from pressurized reservoirs. All three exploration techniques located the reservoirs independent of depth, hydrocarbon type, or trapping style.
1995-12-31
Energy Technology Data Exchange (ETDEWEB)
A new luminescent europium probe is presented for the determination of phosphate (P) in microtiter plate format. The assay is based on the quenching of the luminescence of the europium-tetracycline (EuTc) 1:1 complex by phosphate using a reagent concentration of 20.8 {mu}mol/L. The probe is excited at 400 nm and displays a large Stokes' shift of 210 nm. The emission maximum is located at 616 nm. The system works best at neutral pH 7 and is therefore suitable for phosphate determination in biological and biochemical systems. The linear range of the calibration plot is from 5 x 10{sup -6} mol/L to 7.5 x 10{sup -4} mol/L of phosphate, and the limit of detection is 3 {mu}mol/L.
2006-01-12
Energy Technology Data Exchange (ETDEWEB)
The magnetic susceptibility and electrical resistivity in cerium and neodymium titanate bronzes in Ln/sub 2/3+x/TiO/sub 3+y/ of the perovskite structure were investigated in the temperature range 77-450/sup 0/K. The deviation of the 1/x = f(T) dependence from the Curie-Weiss law, found for a majority of the compositions, was interpreted from the crystal-field effect based on the state of the Ce/sup 3 +/ and Nd/sup 3 +/ cations. For a number of the phases, a transition from metallic conductivity at high temperatures to semiconducting conductivity was detected at temperatures below 200-250/sup 0/K, which agrees well with the conclusion about the temperature dependence of x, related to the subsystem of Ti/sup 3 +/ cations.
1987-01-01
Light emission from hydrogen-copper interaction at grazing incidence
Energy Technology Data Exchange (ETDEWEB)
The optical emission of excited H reflected from clean Cu(110) after impingement of H/sup +/ and H/sub 2//sup +/ in the energy range of 250 eV to 20 keV per nucleon at 70/sup 0/ angle of incidence to the surface normal was measured. For incident 10 keV H/sub 2//sup +/, the highest excited hydrogen state detected was the n=10 level. The Hsub(..cap alpha..) yield was found to be fluence and energy dependent. This effect is attributed either to fast sputtered hydrogen, surface roughness or to an increase with hydrogen concentration in electron states of p-like symmetry near the Fermi level of copper. The Hsub(..cap alpha..) yield per reflected nucleon shows approximately an exponential dependence on both projectile energy per nucleon and scattered particle reciprocal velocity perpendicular to the surface.
1984-03-01
Light emission from hydrogen-copper interaction at grazing incidence
International Nuclear Information System (INIS)
The optical emission of excited H reflected from clean Cu(110) after impingement of H"+ and H_2"+ in the energy range of 250 eV to 20 keV per nucleon at 70"0 angle of incidence to the surface normal was measured. For incident 10 keV H_2"+, the highest excited hydrogen state detected was the n=10 level. The Hsub(#alpha#) yield was found to be fluence and energy dependent. This effect is attributed either to fast sputtered hydrogen, surface roughness or to an increase with hydrogen concentration in electron states of p-like symmetry near the Fermi level of copper. The Hsub(#alpha#) yield per reflected nucleon shows approximately an exponential dependence on both projectile energy per nucleon and scattered particle reciprocal velocity perpendicular to the surface. (orig.).
1983-07-01
K_#beta#/K_#alpha#X-ray intensity ratio in the region of 15#<=#Z#<=#22
International Nuclear Information System (INIS)
The X-ray intensity ratio K_#beta#/K_#alpha# has been measured by using a 10 mCi "5"5Fe source (Mn K X-rays) and high resolution Si(Li) detector system coupled to a computer-controlled multichannel analyzer over the range of 15#<=#Z#<=#22. Correction have been made to the measured relative intensities (K_#alpha# and K_#beta# X-rays) for self-absorption in the sample, air, Be-window absorption and detection efficiency. The results are compared with those of other experiments and with the Scofield calculations. (author) 13 refs.; 3 figs.; 2 tabs.
1994-01-01
Inspection pig for gas pipeline
Energy Technology Data Exchange (ETDEWEB)
The ultrasonic inspection pig system was described as being under development. This system was said to adopt the unique wheel type ultrasonic sensor which does not need couplant. This pig was designed to detect external corrosion in long-distance pipelines without interruption of the gas service. The wall-thickness measurement performance test and the travel performance test of the inspection pig in the test line confirmed that these performances satisfied the development specifications. However, the effect induced by the inner surface properties of the pipe and the influence of the pipe`s performance over long distances and for a long period of time still needed to be verified in an actual gas pipeline, and while the pipeline was actually in service. Improvements to the prototype model of the inspection pig were expected to include combinations of inspection pigs, with increases in battery and memory capacities to permit them to cope with in increased number of ...
1992-12-31
Initial airborne CO{sub 2} DIAL measurements: Discussion of results and data analysis considerations
Energy Technology Data Exchange (ETDEWEB)
A detailed discussion of airborne CO{sub 2}, DIAL measurements obtained from the first joint N-ABLE field campaign at INEL is presented. System performance characteristics, including return signal strength, averaging statistics, and temporal correlation as well as multi-line DIAL spectral data are discussed. In particular, we review data acquisition and analysis strategies pertinent to chemical detection from a moving platform, such as range determination and correction, and return signal processing (waveform vs. box-car integration, baseline correction). We also report observed effects and variations due to near-field light scattering, pointing and tracking stability, and stack-release plume dynamics.
1997-07-01
Energy Technology Data Exchange (ETDEWEB)
The paper describes the latest developments in STRASSY (Strategy Assistance System), the strategy assistance system for the inspection of nuclear materials. The user can now select the fuel cycle he wishes to investigate from an initial range of 19 facilities. An inspection interface has been developed to enable the details and dates of inspections to be modified. One of the special features of the application of STRASSY in international safeguards is the taking into account of timeliness of detection; certain aspects of the time manager algorithms are presented and analysed, including the guaranteed existence of a solution. The results of a study of diversion paths in a simplified cycle consisting of our facilities are presented. Finally, the modifications necessary to enable STRASSY to be used for a posterior analysis of inspection results are discussed. (authors). 7 refs., 3 figs.
1994-12-31
International Nuclear Information System (INIS)
The population of the hyporheic interstice and moss cushions by meso- and macroinvertebrates as found at the three measuring points along the Alte Riefensbeek and the Grosse Soese, respectively, in the period from March 1987 to May 1988 is studied and evaluated together with chemical measurements performed between 1987 and 1990. The six measuring points are positioned along an acidification gradient ranging from non-acid to severely acidified. Chemical and biological paramerters are studied with regard to their suitability as indicators of acidification. A model is presented which decribes the influence of abiotic anthropogenic and natural factors on invertebrate species diversity and populations and which can serve as a basis for the calculation of critical deposition burdens. (orig.).
1991-09-24
Genetic diversity among Angus, American Brahman, Senepol and Romosinuano cattle breeds:
British Library Electronic Table of Contents (United Kingdom)
Summary The objective of this study was to quantify the genetic diversity among breeds under evaluation for tropical adaptability traits that affect the performance of beef cattle at the USDA/ARS SubTropical Agricultural Research Station (STARS) near Brooksville, FL, USA. Twenty-six microsatellite loci were used to estimate parameters of genetic diversity among the breeds American Brahman, Angus, Senepol and Romosinuano; the latter was comprised of two distinct bloodlines (Costa Rican and Venezuelan). Genotypes of 47 animals from each of these STARS herds were analysed for genetic diversity and genetic distance. Using two methods, the greatest genetic distance was detected between the Costa Rican line of Romosinuano and the Senepol. Gene diversity ranged between 0.64 (Costa Rican line of R...
2007-01-01
Estimation of dietary intake of ochratoxin A from liquorice confectionery
British Library Electronic Table of Contents (United Kingdom)
Ochratoxin A (OTA) was analyzed from 44 liquorice confectionery samples using immunoaffinity cleanup and liquid chromatography coupled with fluorescence detection. The presence of OTA was confirmed by methyl-ester derivatization. Liquorice confectionery samples were purchased from different retail outlets and supermarkets in Spain during 2007-2008, 16 of hard candies and 28 of soft candies. The incidence of OTA varied between 75% and 39% and mean ranged from 2.96 to 0.34mg/kg for hard and soft candies, respectively. Assuming a total mean value of 1.29mgOTA/kg sweet and a consumption of about 1.2g liquorice sweets per day, an OTA weekly uptake of 11ng was obtained, or, based on a total body weight of 30kg for a child consuming these sweets regularly, a weekly intake of 0.37ng/kg body weight...
2009-01-01
Dislocation pinning in electron-irradiated copper as a function of electron energy and irradiation
Dislocation priming measurements were performed in the kHz range in ASARCO copper. The samples and irradiation facilities are constructed so as to allow successive irradiation of samples both with electrons and gamma rays. The gamma rays were produced by stopping 2.8-MeV electrons in a gold target. The change of the type of irradiation could be achieved without any handling of the sample. Thus it is possible to detect rather small differences between the two types of irradiation. Recovery experiments at 400 deg K after 75 deg K irradiation and pinning rates during irradiation at 400 deg K and 75 deg K were made. (GE)
1973-01-01
The concept of the 'white-light cavity' has recently generated considerable research interest in the context of gravitational wave detection. Cavity designs are proposed using negative (or anomalous) dispersion in an intracavity medium to make the cavity resonate over a large range of frequencies and still maintain a high cavity build-up. This paper presents the first experimental attempt and demonstration of white-light effect in a meter long ring cavity using an intracavity atomic medium. The medium's negative dispersion is caused by bi-frequency Raman gain in an atomic vapor cell. Although the white light condition was not perfectly achieved and improvements in experimental control are still desirable, significantly broad cavity response over bandwidth greater than 20 MHz has been observed. These devices will have potential applications in new generation laser interferometer gravitational wave detectors.
2006-01-01
DARWIN mission proposal to ESA
The discovery of extra-solar planets is one of the greatest achievements of modern astronomy. There are now more than 200 such objects known, and the recent detection of planets with masses approximately 5 times that of Earth demonstrates that extra-solar planets of low mass exist. In addition to providing a wealth of scientific information on the formation and structure of planetary systems, these discoveries capture the interest of both scientists and the wider public with the profound prospect of the search for life in the Universe. We propose an L-type mission, called Darwin, whose primary goal is the study of terrestrial extrasolar planets and the search for life on them. By its very nature, Darwin advances the first Grand Theme of ESA Cosmic Vision. Accomplishing the mission objectives will require collaborative science across disciplines ranging from planet formation and atmospheres to chemistry and biology, and these disciplines will ...
2007-01-01
Corrosion behaviour of Alloy 800 in high temperature aqueous solutions: Electrochemical studies
International Nuclear Information System (INIS)
The anodic behaviour and passivity breakdown of Alloy 800 in aqueous solutions of sodium chloride, sodium sulphate and sodium bicarbonate were studied by electrochemical techniques in the temperature range from 60 C to 280 C. The pitting resistance and pitting morphology of the alloy in chloride plus sulphate and chloride plus bicarbonate mixtures, at 60 C and 280 C, were also examined. Increasing bicarbonate or sulphate additions to chloride solutions shift the characteristic pitting potential of Alloy 800 to higher values, both at low and high temperatures. Changes in pitting morphology were observed in sulphate containing solutions while the morphology of the attack found in bicarbonate containing solutions was similar to that in pure chloride solutions. Finally, no localized or substantial generalized corrosion was detected in pure sulphate or bicarbonate solutions at any temperature. (orig.).
CO and CO2 emissions from spontaneous heating of coal under different ventilation rates
British Library Electronic Table of Contents (United Kingdom)
Carbon monoxide (CO) and carbon dioxide (CO2) emissions during a spontaneous heating event in a coal mine are important gases to monitor for detecting the spontaneous heating at an early stage. However, in underground coal mines, the CO and CO2 concentrations and their related fire ratios may be affected by mine ventilation. In this study, CO and CO2 emissions from spontaneous heating of a U.S. coal sample were evaluated in an isothermal oven under different airflow ventilation rates ranging from 100 to 500cm^3/min. Laboratory experiments were conducted at oven temperatures of 70, 90, and 100^oC. The temperature at the center of the coal sample was continually monitored, while the CO, CO2, and oxygen (O2) concentrations of the exit gas were continually measured. The results indicate that C...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
An alternative utilization is presented for the gaseous ionization chamber in the detection of energetic heavy ions, which is called Bragg Curve Spectroscopy (BCS). Conceptually, BCS involves using the maximum data available from the Bragg curve of the stopping heavy ion (HI) for purposes of identifying the particle and measuring its energy. A detector has been designed that measures the Bragg curve with high precision. From the Bragg curve the range from the length of the track, the total energy from the integral of the specific ionization over the track, the dE/dx from the specific ionization at the beginning of the track, and the Bragg peak from the maximum of the specific ionization of the HI are determined. This last signal measures the atomic number, Z, of the HI unambiguously.
1981-05-01
Biosorption of lead by citrobacter freundii immobilized on hazelnut shells
Energy Technology Data Exchange (ETDEWEB)
Biosorption of lead from aqueous solutions by living and immobilized cell of C. freundii was examined as a function of metal concentration in a batch laboratory bioreactor. Lead concentrations were analyzed using Atomic Absorption Spectrophotometer (AAS). X-ray Energy Dispersion (EDX) analyses were made in order to determine the accumulation of lead on the cells and shell surfaces. Before and after the experiments the biomaterials and adsorbents were examined by Scanning Electron Microscopy (SEM). Biosorption was detected over a range of initial lead concentrations from 25{times}10{sup -3} to 200{times}10{sup -3} kg/m{sup 3}. 15 refs., 4 figs.
1996-12-31
International Nuclear Information System (INIS)
Charge carrier profiles are measured for boron implanted into silicon (E = 30 keV, dose range 5 x 10"1"5 to 2 x 10"1"6 B/cm"2) after rapid isothermal annealing using halogen lamps. Maximum temperatures between 1000 and 1300 "0C and holding times at T/sub max/ of 5 and 20 s are used for the annealing treatment. In a few additional experiments flash lamp annealing at 1350 "0C (pulse duration 20 ms) is investigated. By comparison of the experimental profiles with computer simulations using the SUPREM II program transient enhanced diffusion of boron could be detected in all investigated cases. Maximum charge carrier concentrations above the equilibrium solubility of boron are observed and are discussed. (author).
A study of reconstruction algorithms and filters for an industrial X-ray tomography system
Energy Technology Data Exchange (ETDEWEB)
Computed tomography (CT) has been incorporated in an industrial Diode-Array Digital Radiography (DADR) system. An input data size of 512 pixel points x 400 projections yielded a 400x400 output image matrix. Reconstruction algorithms used are the filtered backprojection (FBP) and the direct Fourier reconstruction (DFR). Various filters were used in the FBP reconstruction process and their effects on image quality were evaluated. A spatial resolution of 100 {mu}m was measured with a block of plates and a minimum detectable feature size in the range of 10-100 {mu}m was measured using thin wires. Industrial specimens imaged have included ceramic samples, ball bearings and integrated circuits. A number of engineering problems have been solved, such as adjustment of the X-ray source, centering of the rotator spindle in the view field and beam-hardening corrections. (orig.).
1990-12-20
A satellite born charged particles telescope for the study of cosmic ray nuclei
Energy Technology Data Exchange (ETDEWEB)
The description of the high energy particle telescope NINA for the study of cosmic ray nuclei is presented. The instrument will be installed on board of the Resource 01 satellite and will fly on a polar orbit at 690 Km. The telescope consists on a pile of 16 detecting planes each of them is composed by two silicon strip detectors with perpendicular strips and has a total area of 60x60mm{sup 2}. The experiment goals are the study of cosmic ray protons and nuclei in the energy range 12-100 MeV/amu. It will be sensitive to the anomalous component and will also make the observation of the large solar flare events and geophysical phenomena as well. This experiment is the first step of the program RIM whose goal is the satellite study of anti particles in primary cosmic rays.
1995-09-01
Environmental monitoring data were collected at and around the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) at the Nevada Test Site. These data are associated with radiation exposure, air, groundwater, meteorology, vadose zone, subsidence, and biota. This report summarizes the 2006 environmental data to provide an overall evaluation of RWMS performance and to support environmental compliance and performance assessment (PA) activities. Some of these data (e.g., radiation exposure, air, and groundwater) are presented in other reports (U.S. Department of Energy, 2006; Warren and Grossman, 2007; National Security Technologies, LLC, 2007). Direct radiation monitoring data indicate that exposure levels around the RWMSs are at or below background levels. Air monitoring data at the Area 3 and Area 5 RWMSs indicate that tritium concentrations are slightly above background levels. There is no ...
2007-06-30
International Nuclear Information System (INIS)
The radiation decimal reduction dose (D_1_0) of toxigenic Vibrio cholerae O1 El Tor, Inaba was determined in vitro (0.13 kGy) and in inoculated fresh fillets of saurel (Trachurus picturatus murphyi) (0.12 kGy) and another Pacific fish species known in Peru as ''lisa'', Mugil cephalus (0.13 kGy), both of which are frequently consumed raw in ''ceviche''. The D_1_0 value was similarly determined in tails of the shrimp species Penaeus vannamei (0.13 kGy). In a second phase of the study, radiation doses in the range 1.0-4.0 kGy were evaluated for use in microbiological shelf-life extension of the selected seafood, and for adverse effects on various sensory attributes (appearance, odor, flavor, and texture). A dose of 1.0 kGy doubled the microbiological shelf-life of fish fillets during post-irradiation storage at 0-1 deg. C to approximately 30 days. This dose was deemed optimal also for preserving all sensory characteristics ...
2001-04-01
International Nuclear Information System (INIS)
Purpose: Treatment results and the pattern of relapse were evaluated in the multimodal treatment of Ewing's sarcomas of the chest wall. Methods and Materials: In a retrospective analysis, 114 patients with non-metastatic Ewing's sarcoma of the chest wall were evaluated. They were treated in the CESS 81, CESS 86, or EICESS 92 studies between January 1981 and December 1993. The treatment consisted of polychemotherapy (VACA, VAIA, or EVAIA) and local therapy, either surgery alone (14 patients), radiotherapy alone (28 patients) or a combination of both (71 patients). The median follow-up was 46.6 months (range 5-170). A relapse analysis for all patients with local or combined relapses was performed. Results: Overall survival was 60% after 5 years, event-free survival was 50%. Thirty-seven patients had a systemic relapse (32.4%), 11 patients had a local relapse alone (9.6%), and 3 patients had a combined local and systemic relapse (2.6%). The risk to relapse locally ...
1998-12-01
International Nuclear Information System (INIS)
Post-irradiation annealing was used to help identify the role of radiation-induced segregation (RIS) in irradiation-assisted stress corrosion cracking (IASCC) by preferentially removing dislocation loop damage from proton-irradiated austenitic stainless steels while leaving the RIS of major and minor alloying elements largely unchanged. The goal of this study is to better understand the underlying mechanisms of IASCC. Simulations of post-irradiation annealing of RIS and dislocation loop microstructure predicted that dislocation loops would be removed preferentially over RIS due to both thermodynamic and kinetic considerations. To verify the simulation predictions, a series of post-irradiation annealing experiments were performed. Both a high purity 304L (HP-304L) and a commercial purity 304 (CP-304) stainless steel alloy were irradiated with 3.2 MeV protons at 360 deg. C to doses of 1.0 and 2.5 dpa. Following irradiation, post-irradiation anneals were performed at ...
2002-04-01
Biological Effects after Prenatal Irradiation
International Nuclear Information System (INIS)
A Task Group of the International Commission on Radiological Protection (ICRP) has finished a report Biological Effects after Prenatal Irradiation (Embryo and Fetus) which has been approved by the Main Commission and Will be Published. Some new important scientific data shall be discussed in this contribution. During the preimplantation period lethality of the mammalian embryo is the dominating radiation effect. However, in mouse strains with genetic predispositions it has been shown that also malformations can be caused. This effect is genetically determined and its mechanisms is different from the induction of malformations during major organogenesis. Radiation exposures during this prenatal period leads ato an increase of genomic instability of cells in the normal appearing fetuses. These radiation effects can be transmitted to the next generation. A renewed analysis of individuals with severe mental retardation after ...
Benchmarks and models for 1-D radiation transport in stochastic participating media
Energy Technology Data Exchange (ETDEWEB)
Benchmark calculations for radiation transport coupled to a material temperature equation in a 1-D slab and 1-D spherical geometry binary random media are presented. The mixing statistics are taken to be homogeneous Markov statistics in the 1-D slab but only approximately Markov statistics in the 1-D sphere. The material chunk sizes are described by Poisson distribution functions. The material opacities are first taken to be constant and then allowed to vary as a strong function of material temperature. Benchmark values and variances for time evolution of the ensemble average of material temperature energy density and radiation transmission are computed via a Monte Carlo type method. These benchmarks are used as a basis for comparison with three other approximate methods of solution. One of these approximate methods is simple atomic mix. The second approximate model is an adaptation of what is commonly called the Levermore-Pomraning model and ...
2000-08-21
International Nuclear Information System (INIS)
... radiation effects human populations low dose irradiation neoplasms radiation
1980-01-01
Radiation protection and the management of radioactive waste in the oil and gas industry
Radiation protection and the management of radioactive waste in the oil and gas industry
2003-01-01
Influence of germanium and oxygen impurities on the radiation hardening of monocrystalline silicon
International Nuclear Information System (INIS)
... defects doped materials germanium infrared radiation monocrystals neutron
Higher harmonics of spontaneous radiation of ultrarelativistic channeled particles
International Nuclear Information System (INIS)
The case of spontaneous radiation of channeled ultrarelativistic particles is considered when the dipolarity condition is not satisfied. The change of the particle longitudinal velocity affecting the maximum radiation frequency is included. The angular and frequency characteristics of the radiation for superhigh energies are studied for the first time. It is shown that there is an optimum energy at which the radiation density is maximum. The influence of the angle at which electrons enter a crystal and of the beam divergence on the radiation is investigated. The problem of quasichanneled particle radiation and also the radiation in axis-plane transitions are considered. (author).
1980-06-01
International Nuclear Information System (INIS)
... pathological changes patients radiation protection radiotherapy diseases
1982-10-25
Contribution to the radiation preparation of wood-plastic materials. Pt. 7
International Nuclear Information System (INIS)
... odd nuclei organic compounds radiation effects radioisotopes synthesis
1974-01-01
Contribution to the radiation preparation of wood-plastic materials. Pt. 6
International Nuclear Information System (INIS)
... compounds polymers polyolefins polyvinyls radiation effects SYNTHESIS.
1974-01-01
Contribution to the radiation preparation of wood-plastic materials Pt. 3
International Nuclear Information System (INIS)
... compounds plants radiation effects radioisotopes reaction kinetics trees
1974-01-01
duced and spontaneous radiation. The amount of polarization is ... of the induced and spontaneous radiation patterns. Therefore ...
Ultraviolet radiation for the sterilization of contact lenses
Energy Technology Data Exchange (ETDEWEB)
Two sources of ultraviolet (UV) radiation with peak wavelengths in the UV-C or UV-B ranges were compared for their ability to sterilize contact lenses infected with Pseudomonas aeruginosa, Streptococcus pneumoniae, Acanthamoeba castellani, Candida albicans, and Aspergillus niger. Also examined was the effect of prolonged UV light exposure on soft and rigid gas permeable (RGP) contact lenses. The UV-C lamp (253.7 nm, 250 mW/cm2 at 1 cm) was germicidal for all organisms within 20 minutes but caused destruction of the soft lens polymers within 6 hours of cumulative exposure. UV-C caused damage to RGP lenses in less than 100 hours. The UV-B lamp (290-310 nm, 500 mW/cm2 at 1 cm) was germicidal for all organisms tested (except Aspergillus) with a 180-minute exposure and caused less severe changes in the soft lens polymers than did the UV-C lamp, although cumulative exposure of 300 hours did substantially weaken the soft lens material. RGP materials ...
1990-10-01
Ultraviolet radiation for the sterilization of contact lenses
International Nuclear Information System (INIS)
Two sources of ultraviolet (UV) radiation with peak wavelengths in the UV-C or UV-B ranges were compared for their ability to sterilize contact lenses infected with Pseudomonas aeruginosa, Streptococcus pneumoniae, Acanthamoeba castellani, Candida albicans, and Aspergillus niger. Also examined was the effect of prolonged UV light exposure on soft and rigid gas permeable (RGP) contact lenses. The UV-C lamp (253.7 nm, 250 mW/cm2 at 1 cm) was germicidal for all organisms within 20 minutes but caused destruction of the soft lens polymers within 6 hours of cumulative exposure. UV-C caused damage to RGP lenses in less than 100 hours. The UV-B lamp (290-310 nm, 500 mW/cm2 at 1 cm) was germicidal for all organisms tested (except Aspergillus) with a 180-minute exposure and caused less severe changes in the soft lens polymers than did the UV-C lamp, although cumulative exposure of 300 hours did substantially weaken the soft lens material. RGP materials ...
Studies on radiation induced changes in bovine hemoglobin type A
International Nuclear Information System (INIS)
In this paper the structural and functional changes of gamma irradiated bovine hemoglobin are presented. Aqueous solutions/1%/of HbO_2 were irradiated in air with doses ranging from 1 to 4 Mrad. Isoelectric focusing indicated change of the charge of irradiated hemoglobin. The isoelectric point of hemoglobin was displaced towards more acid values with increasing doses, up from 1 Mrad. Fingerprint analysis and peptide column chromatography of irradiated hemoglobin demonstrated disturbances increasing with the dose. These changes were confirmed by amino acid analysis which showed that Cys, Met, Trp, His, Pro and Tyr residues were destroyed or modified following irradiation. At doses exceeding 1 Mrad the irradiated solutions of hemoglobin showed a decrease of heme-heme interaction and an increase of affinity for oxygen. Differences observed in oxygen-dissociation curves seem to be correlated with the radiation induced destruction of amino acid ...
Energy Technology Data Exchange (ETDEWEB)
The third regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from December 27, 1988 to May 25, 1989. The parallel operation was resumed on April 28, 1989, 123 days after the parallel off. The facilities which were the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation and emergency electric power generation system. On the facilities which were the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out. As the results, significant in indication was observed in 8 bolts for fixing the flow-changing vanes of primary coolant pumps, and broken valve spindles were found, but other abnormality was not found. The works related to this regular inspection were accomplished within the range of the limit of ...
1990-03-01
International Nuclear Information System (INIS)
In this thesis the rate constants for a number of radical reactions in aqueous solution have been studied in a wide temperature range. The reactions of H with H_2O_2, OH and HO_2 and the reactions of HO_2 with OH, Fe"2"+ and Cu"2"+ have been studied. For each reaction rate constants have been determined as a function of temperature using the technique of high temperature, high pressure (HTP) pulse radiolysis. The rate constants were obtained by fitting a kinetic computer model to the experimental data. From an Arrhenius plot the activation energy of each reaction was determined. The data determined in this way are important for modeling of radiolysis in nuclear light water reactors. A previously developed model for calculation of the effect of water radiolysis products on oxidation and dissolution of spent nuclear fuel has been improved. In the new model, called TraRaMo, simultaneous transport by diffusion and chemical reactions induced by radiolysis can be ...
2003-01-01
Production of wood plastic properties using gamma radiation as a polimerization agent
International Nuclear Information System (INIS)
The properties of wood plastic composites (WPC) based on Pinus Radiata D. Don impregnated with methylmethacrylate and subsequently polymerized with gamma radiation were studied. Different systems of impregnation were utilized, in order to obtain partial and shell loads. The minimum irradiation dose uses was 16 kGy. The following tests were made to the material: static bending, compression strenght parallel to grain, hardness, sheer strength, toughness, water absorption, dimensional stability and flame propagation index. To evaluate the testing, the results of the samples were separated according final density in the ranges: R_1 = 429-483 kg/m3 (without treatment); R_2 = 500-650 kg/m3 and R3 = 651-850 kg/m3. In general, the best results were obtained for samples of high density. The most important results were achieved for dimensional stability, water absorption and hardness. (Author).
1984-01-01
Energy Technology Data Exchange (ETDEWEB)
The preparation of wood-plastic combinations (WPC) using combined methods for curing intermediate products and final products is described. In the first step, impregnated wood was irradiated using doses of 1 to 10 kGy in the presence of chemical initiators of polymerization. Thereafter, curing of this partly cured impregnating mixture was accomplished in the wood at elevated temperatures with the aid of chemical initiators of polymerization. Impregnation mixtures based on unsaturated polyester resins and methyl methacrylate, and the wood species European Beech (Fagus silvatica) and Black Alder (Alnus glutinosa) were used. The results indicate that this method of preparing WPC allows substantially lower radiation doses to be used, i.e., doses in the range of 1 to 2.5 kGy. These doses gelatinate the impregnation mixture in the wood so that the subsequent curing by chemical polymerization initiators proceeds without the impregnation mixture ...
1982-04-01
International Nuclear Information System (INIS)
The preparation of wood-plastic combinations (WPC) using combined methods for curing intermediate products and final products is described. In the first step, impregnated wood was irradiated using doses of 1 to 10 kGy in the presence of chemical initiators of polymerization. Thereafter, curing of this partly cured impregnating mixture was accomplished in the wood at elevated temperatures with the aid of chemical initiators of polymerization. Impregnation mixtures based on unsaturated polyester resins and methyl methacrylate, and the wood species European Beech (Fagus silvatica) and Black Alder (Alnus glutinosa) were used. The results indicate that this method of preparing WPC allows substantially lower radiation doses to be used, i.e., doses in the range of 1 to 2.5 kGy. These doses gelatinate the impregnation mixture in the wood so that the subsequent curing by chemical polymerization initiators proceeds without the impregnation mixture ...
1982-01-01
Parametric study of radiative cooling of solid antihydrogen. Master's thesis
Energy Technology Data Exchange (ETDEWEB)
A computer model of cryogenic system for storing solid antimatter is used to explore the radiative cooling-power requirements for long-term antimatter storage. If vacuum-chamber pressures as low as 10 to -18th power torr can be reached, and the rest of the large set of assumptions is valid, milligram quantities of solid antimatter could be stored indefinitely at 1.5 K using cooling powers of less than a microwatt. Many of the assumptions made are problematic and need verification, as they could potentially change the results greatly. The system modeled is a sphere of solid anti-parahydrogen at 1.5 K or below levitated in a spherical cryogenic vacuum chamber. The free matter gas in the chamber is assumed to be molecular hydrogen, and sublimation of both matter and antimatter is assumed to be negligible. The antihydrogen is assumed to be in thermal equilibrium, although annihilation-energy deposition is localized and hydrogen's thermal-impulse response time ...
1989-03-01
On the determination of the dose-area product during X-ray examinations
International Nuclear Information System (INIS)
Despite its great usefulness in the performance of the recording procedures prescribed by the X-Ray Ordinance the dose-area product is much less frequently measured for X-ray exposures than during fluorscopic examinations. The great multitude of measuring units, mainly on account of different scales of the measuring equipments themselves, is a cause of uncertainty in clinical routine and should be eliminated as far as the circumstances would permit. As the determination of the organ dose is relevant only in very few cases and does not necessarily require previous measurements of the dose-area product, these are of limited practical value in the assessment of individual radiation exposures during radiographic examinations. The measurements may, however, be very helpful in determinations of the radiation dose to the total population, if the future retrievability of the values obtained is ensured. In addition to some measuring values showing past ...
British Library Electronic Table of Contents (United Kingdom)
The L shell fluorescence cross-sections of the elements in range 45Z50 have been determined at 8keV using Synchrotron radiation. The individual L X-ray photons, Ll, La, LbI, LbII, LgI and LgII produced in the target were measured with high resolution Si(Li) detector. The experimental set-up provided a low background by using linearly polarized monoenergetic photon beam, improving the signal-to-noise ratio. The experimental cross-sections obtained in this work were compared with available experimental data from Scofield [1,2] Krause [3,4] and Scofield and Puri et al. [5,6]. These experimental values closely agree with the theoretical values calculated using Scofield and Krause data, except for the case of Lg, where values measured of this work are slighter higher.
2011-01-01
Laser eye protection. Interim report, July 1989-January 1990
Energy Technology Data Exchange (ETDEWEB)
Laser applications have proliferated in recent years and, as to be expected, their presence is no longer confined to the laboratory or places where access to their radiation can be easily controlled. One obvious application where this is so is in military operations where various devices such as laser range finders, target designators, and secure communications equipment elevate the risk of exposure, specifically eye exposure, to unacceptable levels. Although the need for eye protection in the laboratory and other controlled areas has been appreciated since the invention of the laser, the use of lasers in circumstances where safety or the risk of temporary loss of vision, which can not always be ensured by administrative procedures, has made adequate eye protection essential. It is the critical nature of many military operations that has driven the search for eye protection against both nuclear and laser radiation. At the ...
1990-01-01
Jacobi stability of the vacuum in the static spherically symmetric brane world models
International Nuclear Information System (INIS)
We analyze the stability of the structure equations of the vacuum in the brane world models, by using both the linear (Lyapunov) stability analysis, and the Jacobi stability analysis, the Kosambi-Cartan-Chern theory. In the brane world models the four-dimensional effective Einstein equations acquire extra terms, called dark radiation and dark pressure, respectively, which arise from the embedding of the three-brane in the bulk. Generally, the spherically symmetric vacuum solutions of the brane gravitational field equations have properties quite distinct as compared to the standard black hole solutions of general relativity. We close the structure equations by assuming a simple linear equation of state for the dark pressure. In this case the vacuum is Jacobi stable only for a small range of values of the proportionality constant relating the dark pressure and the dark radiation. The unstable trajectories on the brane behave ...
2008-05-15
Energy Technology Data Exchange (ETDEWEB)
The interference of hyperthermia and ionizing radiation, respectively, with the effects of capric (10:0), lauric (12:0), myristic (14:0), oleic (cis-18:1) and elaidic (trans-18:1) acids on the osmotic resistance of human erythrocytes was investigated. The results are summarized as follows: (A) not only at 37 degrees, but also at 42 and 47{degrees}C lauric acid (12:0) represents the minimum chain length for the biphasic behaviour of protecting against hypotonic hemolysis at a certain lower concentration range and hemolysis promotion at subsequent higher concentrations; (B) with increasing temperatures the protecting as well as the hemolytic effects occur at lower concentrations of the fatty acids; (C) the increase of temperature promotes the extent of hemolysis and reduces the extent of protection against hypotonic hemolysis; (D) Gamma-irradiation of erythrocytes selectively affects the concentration of oleic acid at which maximum protection ...
1990-04-01
Influence of the circadian rhythm in cell division on radiation-induced mitotic delay in vivo
Energy Technology Data Exchange (ETDEWEB)
Mitotic delay is described as a classical response to radiation; however, circadian rhythmicity in cell division in vivo has not been considered by many authors. The present study investigated the relation between fluctuations reported as mitotic delay and recovery in vivo and circadian oscillations in mitotic index in mouse corneal epithelium. One aspect involved single doses (approximately 600 rad) given to mice at different circadian stages. The normal circadian rhythm in cell division was never obliterated. Inhibition of mitosis was evident but unpredictable, ranging from 6 to 15 hr after irradiation. Recovery was evident only during the daily increase in mitotic index of controls. The classical interpretation of recovery from mitotic delay may be in an in vitro phenomenon not reflecting in vivo responses, which are apparently strongly circadian stage dependent. The second portion of the study demonstrated a dose-response effect on length ...
1982-01-01
Environmental data for sites in the National Solar Data Network
Energy Technology Data Exchange (ETDEWEB)
The environmental data for the NSDN are presented in the form of tables for each solar site. The solar sites are grouped into 12 zones, each of which consists of several adjacent states. The solar energy sites are in alphabetical sequence within each zone. The tables provide available meteorological data for reporting sites in the NSDN as follows: Insolation - the insolation table presents the total, diffuse, direct, maximum, and extra-terrestrial radiation for the solar site. It also shows the ratio of total extra-terrestrial radiation, as a percent. Temperature - the temperature table gives the average, daytime, nightime, maximum, minimum and inlet-water temperatures for the solar site. Additional tables are presented for some of these NSDN sites, supplying either wind or relative humidity data, or both. Wind - all of the passive and some of the active solar sites are equipped with wind sensors. These provide information for two wind tables. ...
1980-12-01
Analysis on Dose Distribution in Heterogeneous Condition for Narrow 6 MV X-ray Beams
International Nuclear Information System (INIS)
Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous condition since the GAFCHROMICat..EBT film is composed of ...
2010-10-01
A radiation hardening model of 9%Cr-martensitic steels including dpa and helium
International Nuclear Information System (INIS)
This paper provides a physically-based engineering model to estimate radiation hardening of 9%Cr-steels under both displacement damage (dpa) and helium. The model is essentially based on the dispersed barrier hardening theory and the dynamic re-solution of helium under displacement cascades but incorporating a number of assumptions and simplifications [Trinkaus, J. Nucl. Mater. 318 (2003) 234-340]. As a result, the kinetics of the damage accumulation kept fixed, its amplitude is fitted on one experimental condition. The model was rationalized on an experimental database that mainly consists of ?9%Cr-steels irradiated in the range of 50-600 deg. C up to 50 dpa and with a He-content up to 5000 appm. The test temperature effect is taken into account through a normalization procedure based on the change of the Young's modulus and the anelastic deformation that occurs at high temperature. Despite the large experimental scatter, inherent to the ...
2009-04-30
Rotation periods of late-type stars in the young open cluster IC 2602
We present the results of a monitoring campaign aimed at deriving rotation periods for a representative sample of stars in the young (30 Myr) open cluster IC 2602. Rotation periods were derived for 29 of 33 stars monitored. The periods derived range from 0.2d (one of the shortest known rotation periods of any single open cluster star) to about 10d (which is almost twice as long as the longest period previously known for a cluster of this age). We are able to confirm 8 previously known periods and derive 21 new ones, delineating the long period end of the distribution. Despite our sensitivity to longer periods, we do not detect any variables with periods longer than about 10d. The combination of these data with those for IC 2391, an almost identical cluster, leads to the following conclusions: 1) The fast rotators in a 30 Myr cluster are distributed across the entire 0.5 < B-V < 1.6 color range. 2) 6 stars in our ...
1999-01-01
Precise determination of H recoil cross sections for 1.5-3.0 MeV He ions
International Nuclear Information System (INIS)
The differential recoil cross sections of H have been determined for 1.5-3.0 MeV He"+ incidence. In order to obtain precise data, we have performed simultaneous detection and spectrum simulation of recoiled H and backscattered He. In addition, a careful cross check has been made by secondary ion mass spectrometry (SIMS). The present results have revealed a pronounced contribution from a nuclear short-range interaction. The He"+ energy and recoil angle dependence of the H recoil cross sections are well reproduced by adding the nuclear term, which is simply derived from effective range theory. Our computer simulation program of elastic recoil combined with Rutherford backscattering spectra makes it possible to determine the depth distributions of H together with other elements absolutely, without any ambiguities. The present elastic recoil analysis is employed to determine the H composition of amorphous Si(H) films deposited ...
A new method, near-infrared laser desorption/ionization aerosol mass spectrometry (NIR-LDI-AMS), is described for the real time analysis of organic aerosols at atmospherically relevant mass loadings. Use of a single NIR laser pulse to vaporize and ionize particle components deposited on an aluminum probe results in minimal fragmentation to produce exclusively intact pseudomolecular anions at [M-H](-). Limits of detection (total particulate mass sampled) for oxidized compounds of relevance to atmospheric primary and secondary organic aerosol range from 89 fg for pinic acid to 8.8 pg for cholesterol. NIR-LDI-AMS was used in conjunction with the University of Vermont Environmental Chamber to study secondary organic aerosol (SOA) formation from ozonolysis of limonene at total aerosol mass loadings ranging from 3.2 to 25.0 ?g m(-3) and with a time resolution of several minutes. NIR-LDI-AMS permitted direct delineation between ...
2010-10-01
International Nuclear Information System (INIS)
A novel method of luminescence enhancement effect for the determination of balofloxacin (BLFX) was proposed. A new system of the BLFX-Eu3+-SDBS (sodium dodecylbenzene sulfonate) was investigated. It was found that SDBS significantly enhanced the luminescence intensity of the BLFX-Eu3+ complex (about 20-fold). Under the optimized experimental conditions, the system exhibits an excellent linear relationship between the enhanced luminescence intensity and the concentration of BLFX over the range of 1.0x10-8-8.0x10-7 mol L-1 with a correlation coefficient (R) of 0.9994, and the detection limit (3?) of the method was determined as 2.0x10-9 mol L-1. This method has been successfully applied for the determination of BLFX in pharmaceuticals and human urine/serum samples. Compared with most of the other methods reported, the rapid and simple procedure proposed in the text offers higher sensitivity, wider linear range, and better ...
2009-01-01
Hydrolysis of adenosine 5'-triphosphate: an isotope-labeling study
Energy Technology Data Exchange (ETDEWEB)
A combination of /sup 18/O-labeling experiments and kinetic studies to clarify the nonenzymatic hydrolytic pathways of adenosine 5'-triphosphate (ATP) at pH values ranging from 0 to 8.3 has been used in this experiment. In 1 N and 0.1 N HCl, the data are consistent with the hypothesis that hydrolysis occurs by addition-elimination, with initial attack 93% ..gamma.. and 7% ..beta..; both lead only to ADP + P/sub i/. In the subsequent hydrolysis of the ADP to AMP + P/sub i/, attack is 83% ..beta.. and 17% ..cap alpha... At pH 8.3, the data are consistent with the hypothesis that hydrolsysis occurs by elimination-addition. Over the entire pH range studied, no oxygen exchange between water and ATP, ADP, or P/sub i/ was detected. Nonenzymatic hydrolysis and isotopic analysis of the resultant P/sub i/ comprise a preferred means of assaying the isotopic enrichment of (..gamma..-/sup 18/O)ATP to be used in studies of ...
1982-12-15
Energy Technology Data Exchange (ETDEWEB)
A Tm{sup 3+}- Ho{sup 3+} -codoped single crystal of monoclinic BaY{sub 2}F{sub 8} has been characterized by means of high resolution FTIR spectroscopy in the wave number range 2000-24000 cm{sup -1} and in the temperature range 9-300 K. The energy level schemes of the two lanthanide ions as determined by the optical absorption spectra is presented, analyzed, and fitted within a single ion Hamiltonian model. The very small energy separation (about 0.6-1.6 cm{sup -1}) measured between the first and second sublevels of the ground state manifolds for both the ions is in line with the theoretical predictions. The impurity-phonon coupling is put into evidence by the thermally induced line shift and broadening, and by the detection of vibronic replicas of a few lines. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)
2005-01-01
High resolution Fourier transform spectroscopy and crystal-field analysis in Tm,Ho:BaY_2F_8
International Nuclear Information System (INIS)
A Tm"3"+- Ho"3"+ -codoped single crystal of monoclinic BaY_2F_8 has been characterized by means of high resolution FTIR spectroscopy in the wave number range 2000-24000 cm"-"1 and in the temperature range 9-300 K. The energy level schemes of the two lanthanide ions as determined by the optical absorption spectra is presented, analyzed, and fitted within a single ion Hamiltonian model. The very small energy separation (about 0.6-1.6 cm"-"1) measured between the first and second sublevels of the ground state manifolds for both the ions is in line with the theoretical predictions. The impurity-phonon coupling is put into evidence by the thermally induced line shift and broadening, and by the detection of vibronic replicas of a few lines. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)
2005-01-01
Effects of post-irradiation annealing in alpha-particle bombarded molybdenum
International Nuclear Information System (INIS)
Structural variations in 39-MeV alpha-particle irradiated (Tsub(irr) = 60 deg C) polycrystalline molybdenum during post-irradiation annealing were studied by X-ray and TEM methods. Despite the high density of irradiation induced defects in the structure of the specimen X-ray measurements showed zero relative lattice parameter change after an irradiation dose of 1.1 x 10"-_2 dpa. However, during the annealing #delta#a/a was changed in the positive range, exhibiting two peaks - at 100 and 300 deg C - whereas the damage structure detected by TEM indicated no changes. Analysis of the results leads to the conclusion that in the range 100 to 250 deg C migration of isolated vacancies and their annihilation at interstitial clusters as well as possible formation of new vacancy clusters occur. The second peak on the #delta#a/a temperature dependence curve is related to the transformation (probably, thermal disintegration) of vacancy ...
International Nuclear Information System (INIS)
Full text: Founded in 1964, Ankara Nuclear Research and Training Center (ANRTC) conducts and facilitates the scientific activities including training (summer practice, MSc and Ph D studies in physics and chemistry, IAEA fellowship programs etc.), research and other studies in nuclear and related fields. As it's a part of main duties, ANRTC has analysis on the variety of samples, and radiation protection services commercially, for radiation workers in state, public and private sectors. Research, development and application projects implemented in this Center have mostly been supported by State Planning Organization (SPO) and Turkish Atomic Energy Authority (TAEA). In addition to the projects there are on going collaborative studies with some national Universities and International Atomic Energy Agency. The main activities carried out in ANRTC can be summarized as: studies on experimental nuclear physics, application of nuclear techniques such as ...
2004-10-01
The Differentially Expressed Genes by Radiotherapy in the Patients with Uterine Cervix Cancer
Energy Technology Data Exchange (ETDEWEB)
Purpose : To detect differentially expressed genes in the patients with uterine cervical cancer during the radiation therapy. Materials and Methods : In patients with biopsy proven uterine cervical cancer, we took a tumor tissue just before radiation therapy and at 40 minutes after external irradiation of 1.8 Gy. Total RNAs isolated from non-irradiated and irradiated tumor tissue samples were analyzed using the differential-display reverse transcription-polymerase chain reaction (DDRT-PCR). Complementary DNA (cDNA) fragments corresponding to differentially expressed messenger RNAs(mRNAs) were eluted, and cloned. The differential expression of the corresponding mRNAs was confirmed by reverse northern blot. Differentially expressed cDNA bands were sequenced. Nucleotide sequence data were analyzed in the Gene Bank and EMBL databases via the BLAST network server to identify homologies to known genes or cDNA fragments. ...
2001-12-15
Predictive model of electron-beam-induced flashblindness. Final report, November 1983-October 1984
Energy Technology Data Exchange (ETDEWEB)
The spectral characteristics of the Cherenkov radiation have been evaluated and converted to equivalent retinal irradiance from external sources. On the basis of the conversion, electron fluxes have been estimated for 2-sec recovery times from flashblindness. The electrons are assumed to have energies greater than 6 MeV and to be delivered in one or more bursts of 1 microsecond each over 1 sec. It is important to note that very little data exists on recovery times as short as 2 sec for either photopic and scotopic conditions. This situation is a direct result of the lack of definition of the critical tasks and their sensitivity to an interruption of background adaptation. The Cherenkov radiation produced within the eye by relativistic electrons can be compared to light from external sources by the relationships: 1 rad approx. = 4.6 scotopic td-sec and 1 rad approx. = 0.55 photopic td sec. Based on these conversion factors, the following ...
1985-03-01
Energy Technology Data Exchange (ETDEWEB)
Radiation inactivation and sedimentation equilibrium analysis were used to determine the functional and physical size of the chicken hepatic membrane receptor that binds N-acetylglucosamine-terminated glycoproteins. Purified plasma membranes from chicken liver were irradiated with high energy electrons and assayed for 125I-agalactoorosomucoid binding. Increasing the dose of ionizing radiation resulted in a monoexponential decay in binding activity due to a progressive loss of binding sites. The molecular mass of the chicken lectin, determined in situ by target analysis, was 69,000 +/- 9,000 Da. When the same irradiated membranes were solubilized in Brij 58 and assayed, the binding protein exhibited a target size of 62,000 +/- 4,000 Da; in Triton X-100, the functional size of the receptor was 85,000 +/- 10,000 Da. Sedimentation equilibrium measurements of the purified binding protein yielded a lower limit molecular weight of 79,000 +/- 7,000. ...
1990-03-05
Electron-beam induced RAFT-graft polymerization of poly(acrylic acid) onto PVDF
Energy Technology Data Exchange (ETDEWEB)
This paper explores for the first time the post-radiation-induced-graft polymerization on solid substrate using reversible addition-fragmentation transfer (RAFT) mechanism. Radiation-induced graft polymerization onto polymers is a potentially interesting technique to create easily new materials from highly resistant polymers, e.g. surface graft polymerization of acrylic acid (AA) onto poly(vinylidene difluoride) (PVDF) improves its surface properties without losing its excellent mechanical properties. As a consequence of the radical nature of the polymerization processes it is difficult to control molecular weight of grafted chains, and therefore design and standardize the properties of the final product. RAFT polymerization is a suitable method to obtain monodisperse polymers. The ability of the RAFT agents to control the polymer chain length could be an interesting approach to improve the grafted polymers obtained by ...
2005-07-01
International Nuclear Information System (INIS)
Radiation chimeras in the early phase after bone marrow transplantation are a good model to study the efficiency of the body's nonspecific defense system represented by macrophages (M phi), polymorphonuclear cells (PMN), and NK cells. These cell types are present in large numbers in spleen and liver at that time, whereas the specific immune system represented by T and B cells is functionally deficient. We previously reported enhanced activities in vitro of M phi (and PMN) from recipient animals in an early phase after allogeneic bone marrow transfer. We here demonstrate that these activities result in enhanced spontaneous resistance against Listeria monocytogenes in vivo: CFU of L. monocytogenes in spleen and liver 48 h after infection were about 1 or 2 to 4 log steps less than in untreated control mice of donor or host haplotype. This enhanced resistance decreased over the 4-mo period after marrow transfer. Preactivated M phi were identified as the most important ...
Energy Technology Data Exchange (ETDEWEB)
Food-grade PVC and PVDC/PVC films containing 28.3% dioctyladipate (DOA) and 5.0% acetyltributylcitrate (ATBC) plasticizers, respectively, were brought into contact with olive oil and were irradiated with {gamma}-radiation [{sup 60}Co] at doses equal to 4 kGy and 9 kGy corresponding to `cold pasteurization`. Irradiation was carried out at 8-10 C and samples were subsequently stored at 4-5 C. Contaminated oil samples were analysed for DOA and ATBC at intervals between 7 h and 97 h of contact, using an indirect GC method. Identical non-irradiated (control) samples were also analysed for DOA and ATBC content. Results showed no statistically significant differences in migrated amounts of DOA and ATBC between irradiated and non-irradiated samples. Neither were differences observed between samples irradiated at 4 kGy and 9 kGy. This was supported by identical IR spectra recorded for irradiated and non-irradiated samples and leads to the conclusion that at such ...
1995-12-31
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
