The atomic explosions in Hiroshima and Nagasaki made the name radiation itself become a nightmare. Notwithstanding this, radiation continued to serve the mankind specially in diagnosis of several human diseases and in the treatment of intractable malignancies. With their latest research tools biologists have now shown a significant shift in the earlier paradigm; even the concept that radiation initiates cancer appears to be no longer tenable. On the contrary, selective radiation doses inhibit growth of cancer cells and radiation in combination with many chemotherapeutic drugs, radiosensitizing chemicals and/or hyperthermia, is emerging as a new modality for cancer treatment which offers high therapeutic advantages. In addition, the deleterious effects of radiation can now be strategically counter poised by the use of many drugs and chemicals. This has been ...
It was developed a new formulation of macro aggregates of Samarium 153 ({sup 153} Sm-MH) for the arthropaties treatment. The radio pharmaceutic was prepared by reaction of Samarium 153 chloride (SmCl{sub 3}) in aqueous environment with sodium boron hydride in NaOH 0.5 N. The microscopic analysis shown that the particles have an average size of 4% m (range 1-14 {mu} m). The velocity of sedimentation was 0.008 cm/min with high stability in vitro in human serum. The biological studies in healthy rabbits, shown that the complex is retained inside the articulation still eight days after of the administration of the radiopharmaceutical. Likewise, it is presented the data of absorbed dose in the different target organs, which was determined by thermoluminescent dosimetry (TLD) through the use of a REMCAL phantom (radiation equivalent manikin calibration). (Author)
Large-scale field tracer experiments have been conducted on Ulchin and Wolsung nuclear sites for the purpose of validating FADAS and of analyzing the environmental characteristics around the nuclear site. The most influential factor in atmospheric dispersion is the meteorological condition. During the experiment, meteorological data were measured on the release point and the selected positions among sampling points. Once radioactive materials are released to the atmosphere, members of public may be exposed through the environmental media such as air, soil and foods. Therefore, to protect the public, adequate countermeasures should be taken at due time for those exposure pathways. Both processes of justification and optimization are applied to a countermeasure simultaneously for decision-making. The work scope of biological research for the radiation protection had contained the search of biological microanalytic methods for ...
Summaries are included of research contracts which expired prior to Dec. 31, 1960. The contracts were concerned with investigations of: electrophysiological responses of biological systems in nerve cells to irradiation with small doses of ionizing radiations; the mode of the protective action of certain sulfhydryl compounds against radiation effects on the synthesis of deoxyribonucleic acid, using tritium-labeled thymidine; development of a bubble chamber method of monitoring and dosimetry for Low fast neutron fluxes; effects of incorporated radioisotopes on the stability of genetic materials; interrelation of root and leaf absorption of radioisotopes in herbaceous plants; uptake of radioactive wastes by lowland rice from soils contaminated by irrigation water, and decontamination of the rice; and comparison between mutation rates induced by acute and chronic gamma irradiations. ...
Nov 8, 2010 ... Ihring Mission 11, the radiationdosimetry measurement system functioned normally and provided data on the Earth's trapped radiation belts ...
This manual is a guide to the services provided by the Hanford Internal Dosimetry Program (IDP), which is operated by the Pacific Northwest National Laboratory.( ) for the U.S. Department of Energy Richland Operations Office, Office of River Protection and their Hanford Site contractors. The manual describes the roles of and relationships between the IDP and the radiation protection programs of the Hanford Site contractors. Recommendations and guidance are also provided for consideration in implementing bioassay monitoring and internal dosimetry elements of radiation protection programs.
This report summarizes the activities and major accomplishments for the Idaho National Laboratory Advanced Radiotherapy Research Program for calendar year 2004. Topics covered include boron analysis in biological samples, computational dosimetry and treatment planning software development, medical neutron source development and characterization, and collaborative dosimetry studies at the RA-1 facility in Buenos Aires, Argentina.
Abstracts of research projects are presented in the following areas: measurements and special facilities; cellular and subcellular studies; physiology; behavior; environmental effects; modeling, scaling and dosimetry; and high voltage direct current. (ACR)
By using EPR measurements of radiation-induced radicals it is possible to utilize human fingernails to estimate radiation dose after-the-fact. One of the potentially limiting factors in this...Full Text Available
This book examines the applications of Monte Carlo (MC) calculations in therapeutic nuclear medicine, from basic principles to computer implementations of software packages and their applications in radiationdosimetry and treatment planning. It is written for nuclear medicine physicists and physicians as well as radiation oncologists, and can serve as a supplementary text for medical imaging, radiationdosimetry and nuclear engineering graduate courses in science, medical and engineering faculties. With chapters is written by recognised authorities in that particular field, the book covers the entire range of MC applications in therapeutic medical and health physics, from its use in imaging prior to therapy to dose distribution modelling targeted radiotherapy. The contributions discuss the fundamental concepts of radiationdosimetry, ...
Pilot-plant irradiation began in Hungary in 1969 with the construction of a high-activity multi-purpose /sup 60/Co facility. Technologies for radiation sterilization, food handling, plastics irradiation as well as chemical dosimetry, semiconductor instrumental dosimetry, computer-based construction and control methods have been developed. Our chlorobenzene dose-meter system is used in Hungary and abroad; as a result of an IAEA-organized dosimetric intercomparison the system was adopted as a reference system. The institute has developed into a basic institute for the reconstruction and re-load of old ..gamma..-facilities as well as it serves for the planning, construction and launching of new ones in Hungary.
The book examines current experimental and clinical knowledge concerning the biological and biophysical effects of electromagnetic radiation, particularly that in the microwave range. The biophysical bases of the interaction of electromagnetic radiation with matter are reviewed with emphasis on biological systems, and the effects of radiation on critical biological systems, including the nervous, reproductive, visual and blood-forming systems are compared. Data concerning the lethal effects of nonionizing radiation is presented and characteristics of the effects of electromagnetic radiation on the whole mammalian organisms are examined. Various reactions of the neuroendocrine system to electromagnetic radiation are described, with particular attention given to the adrenal system, and the combined ...
Tritium dose management is an important aspect of the radiation protection program at CANDU type reactor sites. This paper describes the bioassay and dosimetry of tritium at CANDU reactor sites, especially for Wolsung Nuclear Power Plant. It presents a compilation of information drawn from published papers, technical reports, international and national guidelines as well as practical experience both in Korean and Canadian CANDU Nuclear Power Plants. The implementation of this program would provide a technical basis for calculations and records should be of acceptable quality and should meet overall radiation protection program objectives.
This document is the report of a task group of the Radiation Therapy Committee of the AAPM and has been prepared primarily to advise hospital physicists involved in external beam treatment of patients with pelvic malignancies who have high atomic number (Z) hip prostheses. The purpose of the report is to make the radiation oncology community aware of the problems arising from the presence of these devices in the radiation beam, to quantify the dose perturbations they cause, and, finally, to provide recommendations for treatment planning and delivery. Some of the data and recommendations are also applicable to patients having implanted high-Z prosthetic devices such as pins, humeral head replacements. The scientific understanding and methodology of clinical dosimetry for these situations is still incomplete. This report is intended to reflect the current state of scientific understanding and technical ...
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/..gamma.. ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time ..gamma.. spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded ..gamma.. spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, ...
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/#gamma# ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time #gamma# spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded #gamma# spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, ...
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/gamma ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time gamma spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded gamma spectra created by the photopeak-compton edge combination in the plateau portion of the knee response, correcting ...
Thermoluminescence (TL) dosimetry was used to measure dose effects on the raw stock material of borosilicate container glass from different geographical locations. Effects were studied at times up to 60 days post-irradiation at doses from 0.15 to 20 Gy. The minimum detectable dose using this technique was estimated to be 0.15 Gy which is roughly equivalent to a 24 hr irradiation 1 cm from a 50 ng source of 60Co. Two peaks were identified in the TL glow curve, a relatively unstable peak around 125 C and a more stable peak around 225 C. Differences in TL glow curve shape and intensity were also observed for the glasses from different geographical origins. We investigate radiation induced defects in glass to further develop the technique of intrinsic dosimetry - the measurement of the total absorbed dose received by the walls of a container holding radioactive material. Intrinsic dosimetry is intended to ...
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, ...
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, ...
Electron spin resonance spectroscopy can provide a powerful approach to the study of radiation effects in biological materials. This memorandum gives an overview of current and future research. (author).
The radiation dose to a series of adult and paediatric patients undergoing cardiac catheterisations and adults having percutaneous transluminal coronary angioplasty has been measured/determined directly using lithium fluoride thermoluminescent dosemeters and indirectly using an air ionisation chamber which indicated exposure-area product. Somatic and genetic risks are estimated from the dosimetry results. It is suggested that the magnitude of the radiation hazard is negligible compared with other clinical hazards associated with these procedures. (author).
The biological age (BA) of the majority of the liquidators of the consequences of the radiation accidents in the Navy and of the liquidators of the Chernobyl' APS accident exceeds the medium standard and the DBA (due BA). The index of the BA can be a characteristic of the influence of the social-hygienic factors on the health condition of the Special Risk Subunit--the liquidators of the consequences of the radiation accidents. It was established, that the radiation influence concerns to the factors dramatically increasing the BA and the rate of senescence of the liquidators of the consequences of the radiation accidents. PMID:21809627
Topics of this proceedings are: DNA damage and repair; Space research; Cell and tissue radiobiology; Treatment planning 1: The role of clinical RBEs; Treatment planning 2: Dose optimization and inverse planning; Dosimetry; Clinical results of particle therapy and new techniques; Status reports and future developments. Separate abstracts were prepared for 79 chapters. (orig./SR)
DOE installations possessing sufficient quantities of fissile material to potentially constitute a critical mass, such that the excessive exposure of personnel to radiation from a nuclear accident is possible, are required to provide nuclear accident dosimetry services. This document describes the personal nuclear accident dosimeter (PNAD) used by SNL and prescribes methodologies to initially screen, and to process PNAD results. In addition, this report describes PNAD dosimetry results obtained during the Nuclear Accident Dosimeter Intercomparison Study (NAD23), held during 12-16 June 1995, at Los Alamos National Laboratories. Biases for reported neutron doses ranged from -6% to +36% with an average bias of +12%.
This text-book (electronic book - multi-media CD-ROM) constitutes a course-book - author's collection of lectures. It consists of 13 lectures in which the reader acquaints with the basis of radiobiology: Introduction to radiobiology; Physical fundamentals of radiobiology; Radiation of cells; Modification of radiation damage of cells; Reparation of radiation damage of cells; Radiation syndromes and their modification; Radiation injury; Radiation damage of tissues; Effect of radiation on embryo and fetus; Biological effects of incorporated radionuclides; Therapy of acute irradiation sickness; Delayed consequences of irradiation; Radiation oncology and radiotherapy. This course-book may be interesting for students, post-graduate students of chemistry, biology, physics, medicine as ...
Passive dosimeters for personal and area radiation monitor in space have been developed mainly for dosimetry in low-earth-orbit (LEO) radiation environments of Space Shuttles and the International Space Station. The responses of several dosimeters have been evaluated by heavy ions and also its variation for individual dosimeter element. (author)
The book is divided into two approximately equal parts. The first four chapters are relatively lengthy and cover the basic principles of radiationbiology, carcinogenesis and therapy, along with a brief introduction to radiological physics to orient the reader without background in this specialized related discipline. The remainder consists of twenty-four relatively brief chapters, each covering the radiationbiology of a specific organ, tissue, or systems tissues, with emphasis on the tumorigenic and tumoricidal action of ionizing radiations.
Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbed dose to 12 MeV absorbed dose of 0.66 at a distance of 91.4 m from the accelerator. This is ...
This works evaluates by punctuation the performance in conventional Brazilian industries radiation protection area which make use of small industrial gauges and industrial radiography. It proposes, procedures for industry self-evaluation, besides a new radiation protection plans pattern for the small industrial gauges area. The data source where inspection reports of DosimetryRadiation Protection Institute/Nuclear Energy Commission conventional Brazilian industries' radiation protection plans, beyond visitation to the inspection place. The performance evaluation has been realized both in the administrative and operational aspects of the industries. About of 60% of the industries have a satisfactory register control which does not happen to the operational control. The performance evaluation advantage is that industries may self-evaluate, foreseeing ...
The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. ...
Faced with increasing indications for the use of iodine-131 labelled lipiodol in the treatment of hepatocellular carcinoma (HCC), it appears essential to develop an individualized dosimetrY so we can predict the potential effectiveness of this treatment and adjust the activity to be injected. We developed a dosimetric protocol based on imagery and dedicated to calculation of the tumoral dose during the treatment of hepatocellular carcinoma by iodine-131 labelled lipiodol. This concept was developed on a SPECT- CT gantry, and integrates corrections for the phenomena of attenuation, diffusion and dead time. The dose is calculated according to the formalism proposed by the Medical Internal Radiation Dose Committee (MIRD). This protocol was applied to a series of 41 patients in the framework of a retrospective study. The results obtained in terms of biodistribution are compatible with previously published data. The total ...
The dosimetry for radiotherapy involving neutrons is very complicated, owing to the complexity of secondary radiation components, whose contributions to the total absorbed dose have to be discriminated, owing to the different radiobiological effects. In order to separate thermal neutrons and photons, LiF dosimeters are mostly utilized. containing different percentage of Li, like as TLD-700, TLD-100 and TLD-600, but many problems arise. In the response of TLD-700 exposed to neutron-gamma mixed fields with high neutron flux, the contribution of thermal neutrons to the Tl emission is high. Moreover. TLD-100 and TLD-600 may undergo radiation damage, and great care has to be taken in order to obtain reliable results. Other TLDs showing lower sensitivity to neutrons are proposed and experimented for such high-flux neutron fields. The faced problems and various proposed solutions are here described. (Author)
The technical complexity of intraoperative radiotherapy (IORT) requires modification of the standard physical and dosimetric methods used in external electron beam therapy. At the National Cancer Institute, a number of technical innovations have been integrated into ongoing clinical studies of IORT. These include: (1) an electron beam applicator system that is significantly different from other IORT systems and includes customized squircle applicators; (2) peripheral dose shields; (3) a modified surgical table replacing the standard radiation treatment couch; and (4) routine use of multiple IORT fields that necessitates field matching. The IORT applicator system and related devices and techniques are dosimetrically characterized in detail both for use in the IORT program and in order to illustrate many useful facets of electron dosimetry.
The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration certificate and data sheets are presented. (author)
Procedures for {sup 131}I ablation in renal failure are not known. In one patient receiving dialysis, detailed dosimetry and health safety aspects were obtained. The results showed insignificant contamination of equipment, but a surprisingly significant reduction in biologic half-life of {sup 131}I due to efficient dialysis extraction. The data indicate that {sup 131}I ablation can be done safely and easily during dialysis but that much higher {sup 131}I doses must be used to achieve equivalent results to those obtained in patients with normal renal function.
This report is a summary of the progress and research produced for the Idaho National Engineering and Environmental Laboratory (INEEL) Boron Neutron Capture Therapy (BNCT) Research Program for calendar year 1996. Contributions from the individual investigators about their projects are included, specifically, physics: treatment planning software, real-time neutron beam measurement dosimetry, measurement of the Finnish research reactor epithermal neutron spectrum, BNCT accelerator technology; and chemistry: analysis of biological samples and preparation of {sup 10}B enriched decaborane.
A set of eight questions was put to advanced nuclear medicine physicians-in-training participating in a continuing assessment exercise in practical therapeutic nuclear oncology. Using the particular example of {sup 131}I-MIBG treatment of neuroblastoma in children, the questions were directed to the rationale of therapy and the contribution of other forms of treatment to toxic effects. The best answer to the questions are reproduced together with an introduction by the examiner, Dr. H. Turner. tabs.
Present-day requirements for radiotherapy equipment are considered. The recently developed linacs of LUE-5, LUE-25, LUE-15MM models, as well as a newly designed unified series of medical linacs of LUER-5M, LUER-20M, LUER-40M models are described in brief. The main scientific and technical problems that were solved during their construction, namely, development of accelerating structures, a radiation head, dosimetry equipment, a programming unit, a magnetic mirror etc. are described.
Characteristics of the Ukrainian NSA NRI radiation facility for scientific researches and developments of industrial radiation technology are performed. Parts of the facility, design peculiarities of technical tools are described. Biological protection of the facility and radiation protection system, transport line, systems of technical provision and radiation measurements are discussed
The book presents a very good account of all aspects of protection from ionizing radiation. The quantities and units are given and defined used in nuclear physics and dosimetry. The effects of ionizing radiation on cells and on man are described. The principles are presented of radiation protection including limits and valid regulations and decrees. Also discussed is internal irradiation and its modelling. A great part of the book is devoted to aspects of monitoring persons, the living and working environment and to the determination of internal contamination. The system of radiation protection in Czechoslovakia is described and some practical questions are discussed of protection during radiodiagnosis and radiotherapy, in the nuclear fuel cycle, in the operation of nuclear power installations and in crack detection. In conclusion a survey is given of the population exposure from ...
This book gives an overview of the entire field of radiation protection with the subject areas radioactivity, X-rays, UV radiation, laser beams and high-frequency electromagnetic fields. It deals graphically with the most important physical notions, the incidence, origin, properties and biological effects of types of radiation, administrative and practical protection measures and the code of rules governing them. Apart from fundamentals of radiation protection the emphasis on the following: natural radiation exposure, radiation exposure to radon, disaster relief plans in the environment of nuclear plant, the precautionary radiation protection system evolved after Chernobyl, radiation exposure through UV radiation devices, radio, RF communication, radar, microwave ovens and ...
Dose dependences of conductivity at a temperature of 78 K for InSb and InAs single crystals under reactor fast neutron, 50 MeV proton and 80 MeV alpha particle irradiation up to fluence of 10{sup 17} cm{sup -2} are considered. Special attention is given to non-trivial, but little known semi-conductor characteristics in terms of {sigma}(F) dependence at large fluences, and also to the versatility of such dependence for all semiconductors. The behaviour of semiconductor materials conductivity dependence on fluence presented here may be used for semiconductor dosemeters characterisitic variation forecasting under large fluence measurements and in radiation emergency dosimetry. (author).
During one year more than 40,000 items of information on radiation exposure of personnel involved in the handling of radiation sources and more than 5,000,000 items on irradiation of other people are collected in the authors' laboratory. Considerable progress in assessment of mean annual gonad dose of genetically sifnificant dose was attained by means of an algorithm for a personal computer. This simple and inexpensive system has led to a higher accuracy in the application of protective measures. (author).
It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate dose, two environmental correction factors, ...
Despite high local control rate in Ewing's sarcoma the exact indication of radiation therapy is still controversial as well as the choice of the target volume and the optimal dose of radiation. The importance of the quality of radiotherapy has been stressed in recently published data and has shown a significant impact on long term local control with adequate radiation therapy. The dramatic improvement of precision allowed by the conformal therapy and three dimensional dosimetry allow to expect a decrease of late effects expected for second malignancies. However, late sequelae and radio-induced osteosarcoma still remain the major side effects after radiotherapy. The authors discuss the results of the main trials on Ewing's sarcoma on the choice of dose and target volume. Surgery is still the preferred choice for small tumors if the foreseen outcome is identical. (authors). 28 refs.
During fluoroscopy the examiner is usually protected by a radiation-reducing body shield, leaving the thyroid unprotected. The fact that the thyroid is located in a region of the neck usually covered by the shirt collar led to the idea of designing a tie with lead core, providing easy and ''decorative'' reduction of the radiation dose. Sonographic examinations were carried out in 20 volunteers (10 men, 10 women) to determine the size of the gland and its coverage by such a tie. The reduction of the surface and organ dose was assessed using film dosimetry with scattered radiation, the body of the examiner being simulated by an Alderson phantom. On average 88% of the thyroid gland surface area was covered. Surface dose was reduced to 1%, and organ dose to 10% of the value without the protection tie. (Author).
During fluoroscopy the examiner is usually protected by a radiation-reducing body shield, leaving the thyroid unprotected. The fact that the thyroid is located in a region of the neck usually covered by the shirt collar led to the idea of designing a tie with lead core, providing easy and ''decorative'' reduction of the radiation dose. Sonographic examinations were carried out in 20 volunteers (10 men, 10 women) to determine the size of the gland and its coverage by such a tie. The reduction of the surface and organ dose was assessed using film dosimetry with scattered radiation, the body of the examiner being simulated by an Alderson phantom. On average 88% of the thyroid gland surface area was covered. Surface dose was reduced to 1%, and organ dose to 10% of the value without the protection tie. (Author).
A Pulsed RadiationDosimetry System designed to measure radiation produced by particle accelerators is described. The problems associated with total-dose measurement of irregular shaped pulses of ionizing radiation have been simplified. The system responds to extremely narrow pulses of charged particles or X-rays using a pin diode as the detector. Direct readout of dose in rads (Si) is displayed on a 3-1/2 digit digital panel meter. The system will operate in either the multiple-pulse or single-pulse mode. The multiple-pulse mode would be useful in monitoring or tuning a linear accelerator. In the single-pulse mode the system will automatically display total dose of a transient event in real time and hold that measurement indefinitely or until the next measurement is made. The system features an automatic reset in either mode.
In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component of a fiber-optic ...
Understanding risks from exposures to carcinogens and other chemicals depends upon measurement of their dose to target tissues and their reactivity with critical macromolecules. The authors have used AMS detection of radio-isotopes to assess doses and reactivities at low, environmentally relevant doses. Several biomedical investigations show the effectiveness of quantification of biologically important events at extremely high sensitivity with AMS. Specifically, they have measured the addition of environmental carcinogens such as 2-amino-3,8-dimethylimidazo[4,5-f]-quinoaxaline (MelQx), a chemical found in cooked food, to DNA at concentrations relevant to human exposure. Other low level detection problems in biology, such as immunoassay assessment of small environmental chemicals, is being developed with attomole sensitivity. AMS also aids the assessment of genotoxic risks from chemicals by quantifying the binding of labeled chemicals to DNA. ...
Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be ...
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
The estimation of radiation dose to man from either external or internal exposure to radionuclides requires a knowledge of the energies and intensities of the atomic and nuclear radiations emitted during the radioactive decay process. The availability of evaluated decay data for the large number of radionuclides of interest is thus of fundamental importance for radiationdosimetry. This handbook contains a compilation of decay data for approximately 500 radionuclides. These data constitute an evaluated data file constructed for use in the radiological assessment activities of the Technology Assessments Section of the Health and Safety Research Division at Oak Ridge National Laboratory. The radionuclides selected for this handbook include those occurring naturally in the environment, those of potential importance in routine or accidental releases from the nuclear fuel cycle, those of current interest in ...
When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).
When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).
The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. ...
Ionising radiation induces stable free radicals in chicken bones and in the shell of chicken eggs which can be detected, by the electrons spin resonance (ESR) technique, well beyond the shelf-life of the food and can be used for dosimetry. The method usually adopted to evaluate ``a posteriori`` the dose given during the ionising radiation treatment of food, is the dose additive method. To assess the dose, the ESR signal amplitude of the irradiated food (bone or egg shell in the present case) is measured and then the dose-effect relationship is obtained by re-irradiating the sample with some additive doses (usually of 1 kGy). The dose-effect curve is back-extrapolated and the initial given dose determined. At the Istituto Superiore di Sanita (ISS), Rome, Italy, a research programme was approved two years ago aimed to, (1) study new methodological approaches for ESR dose assessment, and (2) analyse the factors which may ...
Biological wound dressings sterilized with gamma radiation, such as amnion and pig skin, are a reality in Mexico. These tissues are currently processed in the tissue bank and sterilized in the Gamma Industrial Irradiation Plant; both facilities belong to the Instituto Nacional de Investigaciones Nucleares (ININ) (National Institute of Nuclear Research). With the strong support of the International Atomic Energy Agency, the bank was established at the ININ and the Mexican Ministry of Health issued its sanitary license on July 7, 1999. The Quality Management System of the bank was certified by ISO 9001:2000 on August 1, 2003; the scope of the system is "Research, Development and Processing of Biological Tissues Sterilized with Gamma Radiation". At present, more than 150 patients from 16 hosp...
For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)
This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.
This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.
A historical perspective is given of the current paradigm that does not explicitly protect the environment from radiation, but instead, relies on the concept that if dose limits are set to protect humans then the environment is automatically protected as well. We summarize recent international questioning of this paradigm and briefly present three different frameworks for protecting biota that are being considered by the U.S. DOE, the Canadian government and the International Commission on Radiological Protection. We emphasize that an enhanced collaboration is required between what has traditionally been separated disciplines of radiationbiology and radiation ecology if we are going to properly address the current environmental radiation problems. We then summarize results generated from an EMSP grant that allowed us to develop a Low Dose Irradiation Facility that specifically ...
The mission of the Health and Safety Research Division (HASRD) is to provide a sound scientific basis for the measurement and assessment of human health impacts of radiological and chemical substances. Our approach to fulfilling this mission is to conduct a broad program of experimental, theoretical, and field research based on a strong foundation of fundamental physical studies that blend into well-established programs in life sciences. Topics include biomedical screening techniques, biological and chemical sensors, risk assessment, health hazards, dosimetry, nuclear medicine, environmental pollution monitoring, electron-molecule interactions, interphase physics, surface physics, data base management, environmental mutagens, carcinogens, and tetratogens.
Delayed cerebral necroses after irradiation are to be divided into hemispheric and midline lesions, as they differ from each other in several aspects. Apart from the symptoms, they are differing in the duration of latency, in the course and prognosis, and also with regard to morphology. Though there is no doubt that radiation tolerance of cerebral midline structures is relatively limited, on biological grounds, evidence of a difference between the tolerated doses could not be given from the existent inhomogeneous radiation data, with the help of the NSD-concept. Radiation planning for the region of the head, nevertheless, carefully should avoid in every case to involve the structures of the cerebral midline.
Cell death after irradiation occurs by apoptosis in certain cell populations in tissues. The phenomenon also occurs after high linear energy transfer (LET) irradiation, and the relative biological effectiveness (RBE) is 3 to 4 (with respect to low-LET radiation and apoptosis in intestinal crypts) for neutrons with energies of 14 MeV and up to 600 MeV. It is thought that p53 plays a role in the phenomenon, as radiation-induced apoptosis is not observed in p53-null animals. (orig.).
Processing of food with ionizing radiation is a method suitable to enhance shelf-life and hygienic quality. Up to a dose of 10 kGy the method is considered wholesome. In many countries the practical use of food irradiation is increasing, however, in the Federal Republic of Germany the process is strictly forbidden. Applications and methods for radiation processing of food are compiled, limits and prospects are explained, and advantages and disadvantages are compared with traditional methods. Identification of irradiated foods and dosimetry and process control for radiation processing of food are areas where further research is needed. Continuous processing of particulate foods in bulk is an application where electron accelerators might be profitable. Beam parameters and velocity distribution of food particles in the treatment area can be matched for an effective result. Thus, dose distribution can be ...
The work scope of 'Biological Research for the Radiation Protection' had contained the research about ornithine decarboxylase and its controlling proteins, thioredoxin, peroxiredoxin, S-adenosymethionine decarboxylase, and glutamate decarboxylase 67KD effect on the cell death triggered ionizing radiation and H_2O_2(toxic agents). In this study, to elucidate the role of these proteins in the ionizing radiation (or H_2O_2)-induced apoptotic cell death, we utilized sensesed (or antisensed) cells, which overexpress (or down-regulate) RNAs associated with these proteins biosynthesis, and investigated the effects of these genes on the cytotoxicity caused by ionizing radiation and H_2O_2(or paraquat). We also investigated whether genisteine(or thiamine) may enhance the cytotoxic efficacy of tumor cells caused by ionizing radiation (may enhance the preventing effect ...
In its 1990 recommendations, the ICRP considered the radiation risks after exposure during prenatal development. This report is a critical review of new experimental animal data on biological effects and evaluations of human studies after prenatal radiation published since the 1990 recommendations. Thus, the report discusses the effects after radiation exposure during pre-implantation, organogenesis, and fetogenesis. The aetiology of long-term effects on brain development is discussed, as well as evidence from studies in man on the effects of in-utero radiation exposure on neurological and mental processes. Animal studies of carcinogenic risk from in-utero radiation and the epidemiology of childhood cancer are discussed, and the carcinogenic risk to man from in-utero radiation is assessed. Open questions and needs for future research are ...
Project ZEUS was designed to characterize the effects of long-term gamma irradiation on free-ranging meadow voles, and to determine the lowest level of radiation at which biological effects are discernible in the population. Behavioural tests are consider...
Voxel-based prescriptions of deliberately non-uniform dose distributions based on molecular imaging, so-called dose painting or theragnostic radiation therapy, require specification of a transformation...Full Text Available
Reliable values of x-ray and gamma-ray attenuation coefficients of elements and compounds are required in spectrometry as well as in many other scientific, engineering and medical disciplines involving photon radiation
Rats were exposed to aerosols of "2"3"3U and "2"3"2U nitrate in a study of the long-term biological effects. Preliminary radiation dose estimates show lung > skeleton > kidney in each dose group.
DNA double-strand breaks (DSBs) are generally accepted to be the most biologically significant lesion by which ionizing radiation causes cancer and hereditary disease. However, no information on the...Full Text Available
Summaries of research projects conducted during 1978 and 1979 are presented. Subject areas include research medicine, cancer research, environmental physiology, radiation biophysics, and structural biophysics. (ACR)
Experimental investigation data are systematized of free radical states and processes in irradiated proteins. The investigation is performed by the radiospectral methods. Results are discussed in detail of the study of free radicals electronic structure of amino acids, peptides and proteins formed by the action of ionizing radiation. The specificity is stressed of the study of monocrystalls of these compounds by the method of electronic paramagnetic resonance. The nature is also studied of primary centres formed under the effect of radiation on biologically important compounds and their subsequent reactions in solid and liquid solutions. Ion-radical states of different functional groups of the protein molecule are studied. Prospects of the study and the role of anion-radicals in biological processes are discusses.
Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization then used at another site.
In 16 female patients wick colpourethrocystography was performed directly successively with large-size films as well as medium-size films (intensifier fluorography). The area exposure products were measured by a dosemeter closely attached to the diaphragm and separately for radiography and fluorography, resp. Surface doses as well as organ doses were calculated according to Rosenstein. The average radiatin doses of the active bone marrow were 6.03 mGy for examination with large-size films and 1.27 mGy for fluorography; the average gonadal doses were 7.45 mGy and 1.56 mGy, resp. The portion of fluoroscopy in radiation exposure amounted to 14.8% in large-size film examination, but was 74.0% in medium-size examination. Thus the comparative results revealed a significant reduction of the patient's radiation dose by application of intensifier fluorography in colpourethrocystography.
To develop a work in an area with high radiation, it requires of a detailed knowledge of the surroundings work, a communication and effective vision, a near dosimetric control. In a work where the spaces variables and reduced accesses exist, noise that hinders the communication, defendant operative condition, radiation field and taking of decision, it is necessary to have tools that allow a total control of the environment to make opportune and effective decisions, there where the task is developed. Under this elementary concept, it was developed in the Laguna Verde Central a project that it allowed a mechanism, interactive of control in spaces complex; to see, to hear, to speak, to measure. This concept takes to the creation of an equipped system with closed circuit of television, wireless communication systems, tele dosimetry wireless systems, VHS and DVD recording equipment, uninterrupted energy units. The system ...
The stages of processes leading to radiation damage are studied, as well as, the direct and indirect mechanics of its production. The radiation effects on nucleic acid and protein macro moleculas are treated. The physical and chemical factors that modify radiosensibility are analysed, in particular the oxygen effects, the sensibilization by analogues of nitrogen bases, post-effects, chemical protection and inherent cell factors. Consideration is given to restoration processes by excision of injured fragments, the bloching of the excision restoration processes, the restoration of lesions caused by ionizing radiations and to the restoration by genetic recombination. Referring to somatic effects of radiation, the early ones and the acute syndrome of radiation are discussed. The difference of radiosensibility observed in mammalian cells and main observable alterations in tissues and ...
The great uranium debate throughout the industrialised world has intensified awareness of the biological hazards from ionizing radiation. It is therefore appropriate to use this awareness to draw attention to medical X-Radiation which today represents the most significant risk to future generations. There is ample legislation to control proliferation of nuclear development but in diagnostic radiology proliferation is unlimited; most international surveys indicate an unchecked annual growth rate of 15%. The article looks at risk hypotheses, dose measurements and the responsibilities of practising radiographers, and also reviews the international situation as reported at the 1977 world congress of radiation protection.
Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that may be used for diagnostics. To provide shielding for ...
Biological wound dressings sterilized with gamma radiation, such as amnion and pig skin, are a reality in Mexico. These tissues are currently processed in the tissue bank and sterilized in the Gamma Industrial Irradiation Plant; both facilities belong to the Instituto Nacional de Investigaciones Nucleares (ININ) (National Institute of Nuclear Research). With the strong support of the International Atomic Energy Agency, the bank was established at the ININ and the Mexican Ministry of Health issued its sanitary license on July 7, 1999. The Quality Management System of the bank was certified by ISO 9001:2000 on August 1, 2003; the scope of the system is 'Research, Development and Processing of Biological Tissues Sterilized with Gamma Radiation'. At present, more than 150 patients from 16 hospitals have been successfully treated with these tissues. This paper presents a brief description of the tissue ...
In May 1990 a group of scientists representing several federal agencies, the International Society of Regulatory Toxicology and Pharmacology, the private sector, and academia met to develop a strategy to encourage the study of the biological effects of low level exposures (BELLE) to chemical agents and radioactivity. A workshop was held in 1991 with seven invited speakers focusing on the toxicological implications of biological adaptations. The selection of topics and speakers was designed to consider critically the concept of hormesis, not only in a broad, conceptual manner, but also at the molecular and biochemical levels. These presentations offered a complementary perspective on the diverse range of molecular mechanisms that can become activated at low levels of toxicant exposure. In addition to chemical toxicology research, an overview of current research on 'Effects of low-dose radiation on the immune response' was ...
The opportunity of exposure to high-energy radiation up to GeV is increasing as in civilian aircrafts and at particle accelerators. The transport of such energetic particle is still difficult to describe precisely and thus verification by measurement using a well characterized instrument is indispensable for reliable dosimetry. However, no reference calibration field has been established for the high-energy range. We thus propose to use a facility at the summit of Mt. Fuji (3776 m in altitude; N35.36o, E138.73o), the highest place in Japan, for characterization of radiation instruments that are possibly used in high-energy radiation fields. For demonstration of the effectiveness, two moderator-type neutron monitors (NCN1 and WENDI-II) having different energy response functions were employed for cosmic-ray neutron measurements in the summer of 2009. In comparison with numerically simulated values, it was ...
The invention refers a procedure of radiation dose control in irradiated tissues during electron-beam therapy. It aims at meeting the planned radiation dose for diseased tissues and taking care of the healthy ones. Therefore, the dose distribution required is determined before irradiation in consideration of such factors as energy-dependence of detector sensitivity, self-absorption within the tissue, and relative biological effectiveness. Furthermore, the expected intensity distribution of secondary quantum radiation excited in the irradiated tissue is calculated. A radiation detector for local resolution is used for registration. During irradiation the calculated intensity distribution is compared with the measured one. The invention is applicable in radiation therapy with monoenergetic electron beams.
This is a progress report from the Health and Safety Research Division of Oak Ridge National Laboratory. Information is presented in the following sections: Assessment Technology, Biological and Radiation Physics, Chemical Physics, Biomedical and Environmental Information Analysis, Risk Analysis, Center for Risk Management, Associate Laboratories for Excellence in Radiation Technology (ALERT), and Contributions to National and Lead Laboratory Programs and Assignments--Environmental Restoration.
Late somatic and genetic radiation effects are imperfectly understood, particularly in the human species. However the available information is sufficient to draw reasonably precise risk estimates in man for many types of damage by means of scientifically justifiable procedures and with the necessary caution. This overall absolute risk of major somatic and genetic damage may be set at around 10"-"4/rad of chronic whole-body doses.
The assessment and control of fetal exposure to radiation in the workplace is an issue that is complicated by both biological and political/social ramifications. As a result of the dramatic increase in the number of women employed as radiation workers during the past 10 years, many facilities using radioactive materials have instituted fetal protection programs with special requirements for female radiation workers. It is necessary, however, to ensure that any fetal protection program be developed in such a way as to be nondiscriminatory. A study has been initiated whose purpose is to balance the political/social and the biological ramifications associated with occupational protection of the developing embryo/fetus. Several considerations are involved in properly balancing these factors. These considerations include appropriate methods of declaring the pregnancy, training workers, ...
High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions can be quantitatively evaluated thermoluminescent dosimeter (TLD) chips with a dimension of 1/8 and film dosimetry with a spatial resolution of <1 mm used to measure the radiation ...
It is anticipated that early in the next century manned missions into outer space will occur, with a mission to Mars scheduled between 2015 and 2020. However, before such missions can be undertaken, a realistic estimation of the potential risks to the flight crews is required. One of the uncertainties remaining in this risk estimation is that posed by the effects of exposure to the radiation environment of outer space. Although the composition of this environment is fairly well understood, the biological effects arising from exposure to it are not. The reasons for this are three-fold: (1) A small but highly significant component of the radiation spectrum in outer space consists of highly charged, high energy (HZE) particles which are not routinely experienced on earth, and for which there are insufficient data on biological effects; (2) Most studies on the biological effects of ...
A survey is presented of the consequences of the irradiation of the population with ionizing radiation. There is an increased incidence of leukemia in irradiated population groups. Among the inhabitants of Hiroshima and Nagasaki maximum death of leukemia was observed in the years 1951 to 1952. The results are summed up of the observation of carcinoma of the breast, lungs and bronchi, bones, and carcinoma of the thyroid. The effect of radiation on experimental animals is described. It was found that the scatter of the dependence of the incidence of various types of cancer on the dose equivalent apparently reflects differences in the biological mechanism of this incidence and that a proportional relationship cannot be expected between the primary damage of cells during irradiation and the actual manifestation of the disease. (E.S.).
A miniature device is described for measuring integral potential alpha energy concentration of radon daughter products (Csub(Rn)) for personnel and stationary dosimetry. The measuring apparatus consists of an air sampler, filters and TLD detectors. CaSO_4:Dy-teflon pellets were used as the detectors which registrate #gamma# radiation as well. The TLD-effect dependence on the potential alpha energy, as well as the fading of the detectors at 20-60 deg C after 170 hrs operation are presentd. The fading up to 40 deg C has been found to be negligible. The dosimeter may be used to measure Csub(Rh) starting with the 10"5 MeVxh/1 threshold, the accuracy being not worse than +-30%.
The distribution of the central benzodiazepine receptor specific ligand iodine-123 iomazenil was investigated in seven human adults from whole-body scans, blood samples and urine collected up to 24 h after injection. Using 12 source organs, the MIRD method was applied to calculate the absorbed radiation dose of the radioligand in various organs. The urinary bladder wall (0.15 mGy/MBq), lower large intestinal wall (0.071 mGy/MBq) testes (0.044 mGy/MBq) and upper large intestined wall (0.038 mGy/MBq) received the highest absorbed doses. The average effective dose equivalent of "1"2"3I-IBZM for adults was estimated to be 0.033 mSv/MBq. (orig.).
The radiolytic reduction of the Ce4+ in a 0.8N sulfuric acid was examined, with the objective of measuring large radiation doses. the ceric sulphate dosimeter was tested in the range from 1 to 20kGy. The 0.01 M sodium oxalate solution was chosen instead of the arsenious oxide solution (used in the conventional method), in order to obtain a less expensive dosimetric system than that normally use for routine chemical dosimetry. The absorption spectrum of the Ce"4"+ solution presents an absorption peak at 370 nm; the obtained molar extinction coefficients of Ce"4"+ and Ce"3"+ were 5670 and 2.7 M"-"1 cm"-"1 respectively. The purpose of this work was to establish a simple, reliable and inexpensive routine chemical dosimetric system for high doses.
We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and calculated data at full width at half maximum. ...
Megavoltage photon intensity-modulated radiation therapy (IMRT) is typically used in the treatment of prostate cancer at our institution. Approximately 1% to 2% of patients with prostate cancer have hip prostheses. The presence of the prosthesis usually complicates the planning process because of dose perturbation around the prosthesis, radiation attenuation through the prosthesis, and the introduction of computed tomography artifacts in the planning volume. In addition, hip prostheses are typically made of materials of high atomic number, which add uncertainty to the dosimetry of the prostate and critical organs in the planning volume. When the prosthesis is bilateral, treatment planning is further complicated because only a limited number of beam angles can be used to avoid the prostheses. In this case study, we will report the observed advantages of using noncoplanar beams in the delivery of IMRT to a prostate cancer ...
A mixture of aminoacids was irradiated by a scattered proton beam, its energy varying from 4 to 6.6 MeV, by doses up to 5 x 10"1"1 proton/cm"2 for studying the potentiality of abiogenic synthesis of biologically important compounds in space. It was ascertained that increase in the radiation dose and reduction of proton energy involve increase in effectiveness both of destruction of the initial aminoacid (tryptophan, tyrosine, glycine) and synthesis of the relevant dipeptide. Essential influence of mineral substrate on abiogenic synthesis of natural nucleotides under the action of diverse energy sources was pointed out
This monograph provides basic notions and principles in dosimetry and radiation protection in compliance with two fundamental works: IAEA Safety Series No.115 - International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources - and Publication no. 60 of International Commission on Radiological Protection. After the review of quantities and units necessary in radiation protection, the book presents the new values of dose limits as well as the values of 'radiation weighting factor', 'tissue weighting factor' and 'conversion factor intake-dose' (committed effective dose per unit intake) by ingestion and inhalation for 30 most important radionuclides. The new values of dose limits, lower than the old values, are a challenge for the radiation protection, especially of the 'public' where the ...
Full text: The general population is daily exposed to chronic, low doses of ionizing radiation (IR) from both natural and artificial sources. The biological consequences of acute, high dose IR exposure can be readily determined; however, the nature and significance of low dose, low dose-rate IR effects are still the subject of debate. Confounding the issue, are the phenomena collectively referred to as the Radiation-induced Bystander Effect (RIBE). The RIBE describes a collection of in vitro observations that suggest the presence of a soluble, transmissible factor(s) released from irradiated cells that can induce a biological response in un-irradiated cells. The induction, nature and magnitude of the RIBE varies between cell culture systems, radiation sources and end-points measured. Efforts to confirm the presence of the RIBE in vivo have been confined to in vivo-like culture ...
Data from Monte Carlo transport codes are used to model radiobiological effects. We previously reported the Fourier analysis of ionization data generated by simulating a 500-keV proton traversing water. Here, we extend Fourier analysis to energy transfer data of another radiation type, a 14-MeV #alpha#-particle. A radiobiological model based on this frequency-domain analysis views cell as an information processing system . It lends itself naturally to traditional engineering analyses. One engineering principle-the output response of a linear system to random signal-is applied here to explain the fact that there is measurable difference in the magnitude of the biological effectiveness when a given biological system is irradiated with two different radiation types of the same Linear Energy Transfer (LET).
For the safety of astronauts and to ensure the stability and integrity of the genome of microorganisms and plants used in bioregenerative life support systems, it is important to improve our knowledge of the combined action of (space) radiation and microgravity. The SOS-LUX-TOXICITY test, as part of the TRIPLE-LUX project (accepted for flight at Biolab in Columbus on the International Space Station, (ISS)), will provide an estimation of the health risk resulting from exposure of astronauts to the radiation environment of space in microgravity. The project will: (i) increase our knowledge of biological/health threatening action of space radiation and enzymatic DNA repair; (ii) uncover cellular mechanisms of synergistic interaction of microgravity and space radiation; (iii) provide specified...
The space environment consists of a varying field of radiation particles including high-energy ions, with spacecraft shielding material providing the only major protection to astronauts from harmful exposure. Unlike low-linear energy transfer (LET) {gamma} or X-rays, the presence of shielding does not always reduce the radiation risks for energetic charged particle exposure, since the dose delivered by the charged particle increases sharply as the particle approaches the end of its range, a position known as the Bragg peak. The Bragg curve does not necessarily represent the biological damage along the particle traversal, and the 'biological Bragg curve' is dependent on the energy and the type of the primary particle, and may vary for different biological endpoints. Here we used a unique irradiation geometry to measure the biological response ...
The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product measurement in the dosimetry ...
The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. An Effective Dose Equivalent System is ...
Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous condition since the GAFCHROMICat..EBT film is composed of ...
Measuring gene expression using microarrays is relevant to many areas of biology and medicine, such as follow up of developmental stages and diseases onset, and treatment study. Since there can be tens of thousands of distinct probes on an array, each micro array experiment can accomplish the equivalent number of genetic tests in parallel. Arrays have therefore dramatically accelerated many types of investigations. For example, microarrays can be used to identify stress response genes by comparing gene expression in challenged versus normal cells. In the Molecular and Cellular Biology lab (MCB), the micro array experiments are performed within the Genomic Platform, fully equipped to analyse either the behaviour of bacteria during long space flight, the effect of low dose ionising radiation on the developing organism in mice, or the human individual radiation sensitivity. For the low dose effect, two ...
Following the publication (Stenhouse and Baxter, Nature; 267:828 (1977)) of the levels of bomb "1"4C and the residence times of carbon in the human body, excess radiation burdens from this radioisotope are evaluated under the assumption that no radiation dose, however small, can be regarded as entirely harmless biologically. The estimated annual absorbed dose attributable to "1"4C both natural and man-made for 1953-1973 and similar predicted figures for 1975-2025 are shown graphically. The cumulated doses to gonads (over 30 yr) and to bone marrow and bone-lining cells (over 60 yr) and also estimates of the biological damage to reproductive cells from "1"4C #beta#-irradiation (30 yr accumulated dose) are presented. It is concluded from both genetic and somatic considerations, that the potential human radiation burden due to artificially produced "1"4C calculated using the assumptions ...
Safety standards for exposure to radiofrequency radiation must be based upon biologic consequences of exposure to such environments. Behavioral-based measures are considered to be the most-sensitive indices of biological effects. Current safety guidelines are based upon average power density and may not be relevant to the high-peak-power, short pulse width microwave radiation produced by newly developed high peak power microwave sources. The effects of exposure to high-peak-power radiation on reflexive responding and motor function in Fischer 344/N rats were assessed by measuring startle and general activity, and disruption of on-going performance of a rotarod task, respectively. The emitter used was the TEMPO repeat pulse axially extracted vircator. Exposure to single pulses resulted in significant startle responses. Exposure to 1 pps for 10 s produced significant alterations in ...
The aetiology of childhood leukaemia remains generally unknown, although exposure to moderate and high levels of ionising radiation, such as was experienced during the atomic bombings of Japan or from radiotherapy, is an established cause. Risk models based primarily upon studies of the Japanese A-bomb survivors imply that low-level exposure to ionising radiation, including to ubiquitous natural background radiation, also raises the risk of childhood leukaemia. In a recent paper (Wakeford et al 2009 Leukaemia 23 770-6) we estimated the proportion of childhood leukaemia incidence in Great Britain attributable to natural background radiation to be about 20%. In this paper we employ the two sets of published leukaemia risk models used previously, but use recently published revised estimates of natural background radiation doses received by the red bone marrow of British children to ...
An investigation of the intensity of electromagnetic radiation at a wavelength of 185nm emitted by a General Electric mercury discharge, germicidal lamp is described. From the measurement of the transmission of light as a function of wavelength from 185nm to 360nm, it was concluded that this type of germicidal lamp does not produce any biological or chemical effects through the 185nm line; the intensity of the 185nm line transmitted by the lamp was less than 0.1% of that for the 254nm line. Consequently, there was no discernable ozone production. (U.K.).
Conference abstract book contains seven sections: Plenary-4 abstracts; Chemical-9 abstracts; Radiation-7 abstracts; Ultra Low Doses and Medicine-6 abstracts; Biomedical-11 abstracts; Risk Assessment-5 abstracts and Poster Sessions-25 abstracts. Each abstract was provided by the author/presenter participating in the conference.
The physical principals of the interaction between microwaves and matter are considered along with the physical-chemical mechanisms for the absorption of microwave energy by biological tissue. Consideration is given to results of studies of the effects of microwaves on cells, subcellular structures, and membranes. Medical applications of microwaves are discussed along with the development of health standards for the use of microwaves. 122 references.
In radiation processing of food, the product often has to be prepackaged to prevent microbial recontamination during and after irradiation. The packaging material is exposed to radiation during radiation processing and radiation stability is a key consideration in the selection of packaging materials. The effects of ionizing radiation on many food packaging materials at the dose levels recommended for food precessing can be minimized by selecting appropriate radiation resistant materials. It is important to select materials in which chemicals formed as a result of the radiation treatment do not migrate and interact with the food, affecting its organoleptic and toxicological aspects. It is also important to select materials in which the physical properties are not altered to the extent they cannot resist damage during commercial production, ...
Alternatives for developing chronic exposure limits for noncancer effects of trichloroethylene (TCE) were evaluated. These alternatives were organized within a framework for dose-response assessment--exposure:dosimetry...Full Text Available
Radiation therapy has had a significant and an expanded role in the management of cancer of the pancreas during the last decade. In particular, for locally advanced disease, radiation therapy has improved the median survival of patients to 1 year. Intraoperative electron beam therapy has been applied to unresectable and resectable pancreatic cancer in an attempt to enhance local control of disease and to improve patient survival. This paper presents a survey of the role of radiation therapy in treatment of cancer of the pancreas, provides information on the radiobiological aspects of this treatment modality and details the physical and dosimetric characteristics of intraoperative radiation therapy with electrons. Presented are the design specifics of an applicator system, central axis beam data, applicator parameters, dose distribution data, shielding, treatment planning and means of verification. ...
Radiation therapy has had a significant and an expanded role in the management of cancer of the pancreas during the last decade. In particular, for locally advanced disease, radiation therapy has improved the median survival of patients to 1 year. Intraoperative electron beam therapy has been applied to unresectable and resectable pancreatic cancer in an attempt to enhance local control of disease and to improve patient survival. This paper presents a survey of the role of radiation therapy in treatment of cancer of the pancreas, provides information on the radiobiological aspects of this treatment modality and details the physical and dosimetric characteristics of intraoperative radiation therapy with electrons. Presented are the design specifics of an applicator system, central axis beam data, applicator parameters, dose distribution data, shielding, treatment planning and means of verification. ...
This report is a survey of the English language literature of radiationbiology between 1947 and 1987, for the purpose of compiling a literature base on the effects of radiation on animals, which have yielded results that can expand our knowledge about similar radiation effects on human beings. Articles were sought that reported exposure of adult mammals to external sources of ionizing radiation, having endpoints that included effects on the brain, the spinal cord, and behavior of the gastrointestinal, endocrine, and cardiovascular systems and the hematopoietic and immune systems. Effects of interest were those that occurred within the first 12 months after exposure. The survey does not include articles reporting chronic or long term delayed effects of radiation unless they provided insight into mechanisms of morphological and/or functional derangement. ...
The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. ...
The importance of cellular dosimetry in both diagnostic and therapeutic nuclear medicine is becoming increasingly recognized. Experimental range-energy relations for electrons and alpha particles, along with derived geometric reduction factors, are used to calculate cellular absorbed fractions for these radiations. The resulting absorbed fractions are employed to calculate cellular S-values for several radionuclides. Cellular absorbed fractions for monoenergetic electron sources with energies ranging from 0.1 keV to 1 MeV, distributed uniformly in the source region, are calculated for several target {l_arrow} source combinations including cell{l_arrow}cell, cell{l_arrow}cell surface, nucleus{l_arrow}nucleus, nucleus {l_arrow}cytoplasm and nucleus {l_arrow}cell surface. Similar data are also provided for monoenergetic alpha particle sources with energies ranging from 3 to 10 MeV. S-values are also conveniently tabulated for {sup 32}P, {sup 35}S, ...
Radiation damage is considered to be the major problem that still prevents imaging an individual biological molecule for structural analysis. So far, all known mapping techniques using sufficient short wave-length radiation, be it X-rays or high energy electrons, circumvent this problem by averaging over many molecules. Averaging, however, leaves conformational details uncovered. Even the anticipated use of ultra-short but extremely bright X-ray bursts of a Free Electron Laser shall afford averaging over 10^6 molecules to arrive at atomic resolution. Here we present direct experimental evidence for non-destructive imaging of individual DNA molecules. In fact, we show that DNA withstands coherent low energy electron radiation with deBroglie wavelength in the Angstrom regime despite a vast dose of 10^8 electrons/nm^2 accumulated over more than one hour.
Efforts are being made to determine a gamma radiation dose for mortality of third-instar larvae of Anastrepha fraterculus which infest mangos of the Haden variety of 400 g weight. Four radiation treatments were tested: 0.4 kGy, 0.6 kGy, 0.8 kGy and 1.0 kGy. Using as a criterium for mortality the interruption of the biological cycle between larva and pupa, the following results were achieved: 49.61%, 63.33%, 74.86% and 90.72%. The percentages obtained have been corrected using the Abbot formula. When the criterium was based on no adult emergence, 100% mortality was achieved for the four treatments. (author)
The status of neutron activation cross sections for some threshold reactions important for reactor materials dosimetry is reviewed. An attempt is made to understand and explain discrepancies between integral and differential data, using recent available experimental results. The importance of standard and benchmark neutron fields for testing differential data for reactor dosimetry is emphasized and the Interlaboratory Reaction Rate (ILRR) program, as well as a similar program pursued by the IAEA, are briefly described.
An assessment is made of the biological effects and physical hazards of static and time-varying fields associated with the NMR devices that are being used for clinical imaging and in vivo spectroscopy. A summary is given of the current state of knowledge concerning the mechanisms of interaction and the bioeffects of these fields. Additional topics that are discussed include: (1) physical effects on pacemakers and metallic implants such as aneurysm clips, (2) human health studies related to the effects of exposure to nonionizing electromagnetic radiation, and (3) extant guidelines for limiting exposure of patients and medical personnel to the fields produced by NMR devices. On the basis of information available at the present time, it is concluded that the fields associated with the current generation of NMR devices do not pose a significant health risk in themselves. However, rigorous guidelines must be followed to avoid the physical ...
The spectral energy-dependence of the radiation-induced ESR signal has been studied in ovine cortical bone. Crushed bone samples were irradiated using photon beams with effective energies in the range from 0.06 to 6 MeV, and electron beams with mean energies in the range from 2 to 10 MeV. The photon and electron data were normalized to a dose to bone of 50 Gy and the results are reported as response relative to the ESR signal for photon irradiation at 1.25 MeV ("6"0Co). The photon irradiation results show that the ESR response is greatest at low energies with a relative value of 1.2 at 0.06 MeV. The relative response decreases, as the energy increases, to approximately 0.85 in the region of 2 to 3 MeV. These variations in the relative ESR responses are significantly less than the ESR energy-dependent responses reported in the literature for human tooth enamel and synthetic hydroxyapatite. An explanation for this difference is offered. For electron beam ...
A book has been written to introduce the physical aspects of the radiotherapy electron beam by presenting a summary of the developments in this field. The first chapter is a brief introduction to the technology of medical accelerators with emphasis on the electron beam production facilities. Chapter 2 describes the interaction processes at the atomic level once the electron beam enters the medium. Chapter 3 is concerned with the various properties of the electron beam purely from the clinical point of view. The electron beam algorithms and models for distribution calculations are covered in Chapter 4 with inclusion of age diffusion and multiple scattering approaches. The factors affecting the beam distribution in a patient, with inhomogeneities, surface irregularities, backscattering etc. are discussed in Chapter 5. The last two chapters are devoted to electron beam dosimetry including various dosimetric methods, specification and measurement of beam energy, ...
The aim of this work is the evaluation of biodistribution and radiationdosimetry of a cocaine analog, the N-(3-iodo-prop-2E-enyl)-2beta-carbo-methoxy-3beta-(4-methyl-phenyl) nor-tropane (PE2I), labeled with carbon 11 ([{sup 11}C]PE2I). The [{sup 11}C]PE2I is a selective radioligand for imaging neuronal dopamine transporter (DAT) with positron emission tomography (PET). The DAT is a membrane-bound pre synaptically located protein that regulates the concentration of dopamine at nerve terminals. DAT radioligands are often used to evaluate the progression of Parkinson's disease or the efficiency of neuro-protective therapeutics and, typically, these studies required several successive PET scans. (author)
In less than a decade computed tomography (CT scanning) had a profound impact on diagnostic radiology. Radiology of the orbit is no exception. As early as 1973, reports published in the radiological literature indicated that this new noninvasive imaging method was a highly effective way of demonstrating intraorbital mass lesions. As CT scanners became widely available, computed tomography became a significant adjunct to ophthalmological diagnosis. Today the main indications for CT scanning of the orbit are: (1) suspected mass lesions, most frequently presenting as exophthalmos, (2) orbital trauma, including foreign bodies, (3) some congenital anomalies, and (4) suspicion of extension into the orbit of extraorbital disease processes. Along with ultrasonography, another new noninvasive imaging technique, CT has replaced a number of more invasive and often less effective diagnostic methods, such as orbital pneumography, venography, and arteriography as major imaging techniques in orbital ...
The current primary standards at NPL for the measurement of absorbed dose to water in high energy photon and electron beams are graphite calorimeters. However, the quantity of interest in radiationdosimetry is absorbed dose to water. Therefore, a new absorbed dose to water standard based on water calorimetry has been developed for use in high energy photon and electron beams. The calorimeter operates at 4 deg C, with temperature control being provided by liquid cooling. The sealed glass inner vessel of the calorimeter was designed to minimise the effect of non-water materials on the measurement of absorbed dose. The temperature sensing thermistor probes were designed and constructed so that glass is the only material in contact with high purity water inside the vessel. Initial measurements of absorbed dose to water made in 6, 10, and 19 MV photons, and 16 MeV electrons agreed, within the measurement uncertainties of approximately 1.5% (95% ...
Estimations on the somatic and genetic effects of small doses of ionizing radiations in Man have been proposed by the Advisory Committee on the Biological Effects of Ionizing Radiation, set up by the U.S. National Academy of Sciences. They have been published in an important report, issued in 1972, from which we briefly analyze here the Chapter dealing with the somatic effects. Small doses of raditions are expected to promote only carcinogenic effects. After a rapid survey of the human experience on which the estimations are based, as regards the latent period of cancers, the plateau region (period of high risk) and the absolute and relative risk expressed per rem, per 10"6 persons, per year, for leukaemia (having the highest risk) and for the ''other cancers''. These estimations were obtained by linear extrapolation to the 1 rem level from observations made after irradiation at relatively high dose levels and much higher ...
We present the latest developments for the radiation laboratory curriculum at the Department of Physics and Astronomy of Western Kentucky University. During the last decade, the Applied Physics Institute (API) at WKU accumulated various equipment for radiation experimentation. This includes various neutron sources (computer controlled d-t and d-d neutron generators, and isotopic 252 Cf and PuBe sources), the set of gamma sources with various intensities, gamma detectors with various energy resolutions (NaI, BGO, GSO, LaBr and HPGe) and the 2.5-MeV Van de Graaff particle accelerator. XRF and XRD apparatuses are also available for students and members at the API. This equipment is currently used in numerous scientific and teaching activities. Members of the API also developed a set of laboratory activities for undergraduate students taking classes from the physics curriculum (Nuclear Physics, Atomic Physics, and Radiation ...
A Task Group of the International Commission on Radiological Protection (ICRP) has finished a report Biological Effects after Prenatal Irradiation (Embryo and Fetus) which has been approved by the Main Commission and Will be Published. Some new important scientific data shall be discussed in this contribution. During the preimplantation period lethality of the mammalian embryo is the dominating radiation effect. However, in mouse strains with genetic predispositions it has been shown that also malformations can be caused. This effect is genetically determined and its mechanisms is different from the induction of malformations during major organogenesis. Radiation exposures during this prenatal period leads ato an increase of genomic instability of cells in the normal appearing fetuses. These radiation effects can be transmitted to the next generation. A renewed analysis of individuals with severe mental ...
In order to follow some of the changes induced by ultraviolet-B (UV-B, 280-320 nm) radiation in Phaseolus vulgaris and Brassica napus, experiments were designed to localize sites of changes in leaves and to correlate some of the physiological and biochemical changes with penetration of UV-B radiation. B.napus was exposed to 8.9 kJ m"-"2 day"-"1 biologically effective UV-B radiation (UV-B_B_E). The penetration of UV-B radiation into the leaf was followed using a quartz fibre optic microprobe. Monochromatic radiation at 310 nm was decreased by ca 50 and 34% in the adaxial and abaxial epidermis, respectively, in plants not exposed to UV-B, whereas the radiation was decreased by ca 70 and 42%, respectively, in the same region in UV-treated plants. Polychromatic radiation showed a wavelength dependent change mainly for the ...
The quality insurance in radiotherapy in the frame of highly complex technical process as Intensity modulated radiotherapy (I.M.R.T.) needs independent control of the delivered dose to the patient. Actually, up to now, most of the radiotherapy treatments rely only on computed dosimetry through a rather complicated series of linked simulation tool. This dosimetry approach requires also qualified treatment means based on cautious quality insurance procedures. However, erroneous parameters could be difficult to detect and systematical errors could happen leading to radiotherapy accidents. In this context, in vivo dosimetry has a critical role of final control of the delivered dose. As many beam incidences and ports are used for any photon therapy treatment, external control could be very tedious and time consuming. Therefore, innovations are needed for in vivo dosimetry to provide ergonomic and efficient ...
Although low-energy ion radiation has been proven to have a wide range of biological effects and led to fruitful achievements as a new mutagenic source for genetic modification, there still exist some disputes about its mutagenic mechanisms because of its short-penetrating property. In present research, Arabidopsis thaliana transgenic for GUS recombination substrate was used to evaluate the genomic instability induced by irradiations of alpha particle (3.3MeV) and Low-energy-Argon ion (30 KeV). A pronounced effects of alpha particle irradiation to Arabidopsis thaliana seedlings and Argon ion irradiation to seeds on the somatic homologous recombination frequency (sHRF) were reported. The sHRFs increased 1.88-fold and 2.42-fold, respectively, which indicated that the short-penetrating radiation could effectively induce the plant genomic instability in either dry seeds or seedlings with active metabolism. The local alpha ...
Full text: An adaptive response is a decreased biological effect induced by a priming radiation dose given prior to a challenge dose. Adaptive responses contradict the linear-nothreshold model of risk estimation. The pKZ1 mouse chromosomal inversion assay is an extremely sensitive assay for studying the mutagenic effect of low dose radiation. A non-linear dose response for chromosomal inversion has been observed in pKZ1 spleen and prostate after a single whole body irradiation with doses between 1?Gy and 10mGy. Doses between 5-10?Gy resulted in an induction in inversions and doses between 1-10mGy resulted in a reduction below endogenous inversion frequency. These results suggest that doses in the 1-10 mGy range cause host responses which overcompensate by not only preventing inversions that would normally occur as a result of the low doses of radiation but also by preventing some of the endogenous ...
According to ICRP 60 and European-Directive 96/29, Naturally Occurring Radioactive Materials (NORM) and Technical Enriched Naturally Occurring Radioactive Materials (TENORM) have to take the radiation protection of the general population as well as of workers into account. The German radiation protection regulations stress that particularly. In connection with these regulations, various measurement programs have been and still are performed to investigate the relevant exposure paths. One of these programs is the determination of the intake of natural occurring radionuclides of the uranium decay series in individuals of the public, in exposed regions and houses and also at NORM workplaces by excretion analysis. Excretion analysis surveillance is one of the common tools for internal dosimetry. Sources of primordial radionuclides could be the ingestion of foodstuff and water and the incorporation of (mostly airborne) pollution ...
In the Institute of Nuclear Chemistry and Technology research on microbiological decontamination of medicinal herbs by irradiation has been carried out since 1996. It was shown that using ionizing radiation (a dose of 10 kGy) can obtain satisfactory results of microbiological decontamination of these products. The content of essential biologically active substances such as essential oils, flavonoids, glycosides, anthocyans, antra-compounds, poliphenoloacids, triterpene saponins, oleanosides and plants mucus did not change significantly after irradiation. Pharmacological activity of medicinal herbs has been found satisfactory after microbiological decontamination by irradiation.
Original investigations of ablation of minerals, fullerene-like compounds, polymers and complicated biological macromolecules under the action of submillimeter radiation of the free-electron laser (FEL) developed and built at Budker Institute of Nuclear Physics [V.P. Bolotin et al., First experiments on high-power Novosibirsk terahertz free-electron laser, Budker INP, 2005, p. 37 [1
Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)
We present the case of a 12-year-old girl who presented with a pathological fracture through a benign-appearing osteolytic lesion that was presumed to represent fibrous dysplasia. The fracture healed, and over the next 2.5 years there was further refracturing and healing with progressive osteolysis. A biopsy was performed and revealed Ewing's sarcoma. The disease was locally controlled by neoadjuvant chemotherapy and radiation therapy. The patient is disease free with excellent function 6 years following the discovery of the lesion. We illustrate and discuss the sequence of events. (orig.)
Probable risks for the occurrence of somatic effects due to diagnostic radiology and nuclear medicine are summarised. The biological background of radiation carcinogenesis and epidemiological results are discussed. At the Leiden University Medical Centre the average effective dose per examination due to diagnostic radiology and nuclear medicine amount to 0.95 and 4.4 mSv, respectively. These values correspond well with the average values of 0.82 and 3.0 mSv reported for The Netherlands as a whole. Since radiological examinations are performed at a much larger frequency than nuclear medicine the relative collective dose for the first type of examinations is higher than the latter. Risk for occurency of malignancies are at least one order of magnitude lower than the hypothetical risk due to the background radiation typical of The Netherlands.
The biological effects of ionizing radiation exposure are the result of a complex sequence of physical, chemical, biochemical, and physiological interactions. One way to begin a search for an understanding of health effects of radiation is through the development of phenomenological models of the response. Many models have been presented and tested in the slowly evolving process of characterizing cellular response. A range of models covering different endpoints and phenomena has developed in parallel. Many of these models employ similar assumptions about some underlying processes while differing about the nature of others. An attempt is made to organize many of the models into groups with similar features and to compare the consequences of those features with the actual experimental observations. It is assumed that by showing that some assumptions are inconsistent with experimental observations, the job of devising and ...
TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. X-ray conductivity coefficients K_#sigma# characterising X-ray ...
In this updated second edition, the order of contents of the textbook has been reorganized. It has been divided into main parts: Basic Science and Clinical Nuclear Medicine. Basic Science, Part I, encompasses basic physics, radiation protection, interaction of radiation with matter and radiation detection, imaging, nuclear pharmacy, and radiationbiology. Part II, Clinical Nuclear Medicine, covers the central nervous system, bone, gastroenterology (liver/spleen), cardiovascular system, pulmonary system, genitourinary system, thyroid and endocrine systems, gallium studies, radioassay, hematology, and therapy. The total number of pages of the current edition is increased to 250 from the 213 of the first edition but there are fewer questions because those in the basic science area have been carefully selected to 60 of the original 98 questions. Compared with the previous edition, there ...
The use of hypothesis which assumes a dose / harmful effect relationship without a limit allows the calculation of risks attributable to doses too small to produce detectable, harmful biological effects. The daughter product of this hypothesis is ALARA concept which requires that the dose received is kept as low as reasonably achievable. This concept of prudent avoidance is generally accepted by international radiation protection organisations and universally applied by radiation health professionals. The acceptance of a hypothesis which assumes that a single nuclear event can cause carcinogenesis, has generated levels of anxiety which may have resulted in significant detriment to those possibly exposed to ionising radiation. The anxiety generated may have caused more detriment and a higher death rate than the worst case ` theoretical` value calculated using the Linear or Quadratic Linear Hypothesis. ...
Tl(InS_2)_1_-_x(FeSe_2)_x single crystals (where x=0; 0.001; 0.005; 0.01 and 0.015) were grown by the Bridgman-Stockbarger method. Obtained single crystals were crystallized in monoclinic structure. The present paper deals with experimental results relative to X-ray dosimetric characteristics of the Tl(InS_2)_1_-_x(FeSe_2)_x solid solutions at 300 K. Installation URS-55a was the source of radiation. X-ray radiation dose (E) falling on the crystals is measured by the crystalline X-ray dosimeter DRGZ-02. The value of X-ray conductivity coefficient K_#sigma# characterising X-ray sensitivity is defined as K_#sigma#= (#sigma#_E-#sigma#_0)/E#sigma#_0. where #sigma#_E is conductivity under the effect of X-ray radiation by intensity E, #sigma#_0 is conductivity in the lack of radiation. Comparing X-ray dosimetric characteristics of TlInS_2 and Tl(InS_2)_1_-_x(FeSe_2)_x crystals notes that because of partial ...
INAA (instrumental neutron activation analysis) analyses have been made of subsamples of each OSL (Optically stimulated luminescence) sample, for dosimetry ...
Dosimetry parameters such as deposition, clearance, retention, and translocation and dissolution of inhaled particles in and to different lung compartments may be important for the persistence of particles...Full Text Available
Many thermoluminescent materials has been developed and used for photon personal dosimetry but no one has all desired characteristics alone. These characteristics include robustness, high sensitivity, energy photon independence, large range of photon energy detection, good reproducibility, small fading and simple glow curve with peaks above 150 deg C. Calcium Sulfate Dysprosium doped (CaSO{sub 4}:Dy) phosphor Thermoluminescent Dosimeter (TLD) has been used by many laboratories, mainly in Brazil and India. Another interesting phosphor is Calcium Fluoride (CaF{sub 2}). These phosphor advantages begin to be more required and its disadvantages have became more apparent, in a global market more and more competitive. These phosphors are used in environmental and area monitoring, once they present more sensibility than other phosphors, like LiF:Mg. Theirs mainly disadvantage is a strong energetic dependence response, which must be corrected for theirs application in the ...
Sandia National Laboratories (SNL) is committed to conducting its operations in an environmentally safe and sound manner. It is mandatory that activities at SNL/California comply with all applicable environmental statutes, regulations, and standards. Moreover, SNL/California continuously strives to reduce risks to employees, the public, and the environment to the lowest levels reasonably possible. To help verify effective protection of public safety and preservation of the environment, SNL/California maintains an extensive, ongoing environmental monitoring program. This program monitors all significant effluents and the environment at the SNL/California site perimeter. Lawrence Livermore National Laboratory (LLNL) performs off-site external radiation monitoring for both sites. These monitoring efforts ensure that emission controls are effective in preventing contamination of the environment. As part of SNL/California`s Environmental Monitoring Program, an ...
The DOE-Idaho Operations Office (DOE-ID) has prepared an environmental assessment (EA) on the replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory at the Idaho National Engineering Laboratory (INEL). The purpose of this project is to replace the existing Health Physics Instrumentation Laboratory (HPIL) with a new facility to provide a safe environment for maintaining and calibrating radiation detection instruments used at the Idaho National Engineering Laboratory. The existing HPIL facility provides portable health physics monitoring instrumentation and direct reading dosimetry procurement, maintenance and calibration of radiation detection instruments, and research and development support-services to the INEL and others. However, the existing facility was not originally designed for laboratory activities and does not provide an adequate, safe environment for calibration ...
Reactor pressure vessel (RPV) steels are subjected to neutron irradiation at a temperature of about 290 deg C. This radiation exposure alters the mechanical properties, leading to a shift of the brittle-to-ductile transition temperature toward higher temperatures and to a diminution of the rupture energy as determined by Charpy V-notch tests. This radiation embrittlement is one of the important aging factors of nuclear power plants. U.S. NRC recommended the basic requirements for the determination of the pressure vessel fluence by regulatory guide DG-1025 in order to reduce the uncertainty in the determination of neutron fluence calculation and measurements. The determination of the pressure vessel fluence is based on both calculations and measurements. The fluence prediction is made with a calculation and the measurements are used to qualify the calculational methodology. Because of the importance and the difficulty of these calculations, the ...
The patients studied were referred for routine abscess localization with indium-111 labelled autologous leukocytes. One series (n=15) was studied at 1 day after reinjection of labelled cells and a second series (n=9) was studied between 4 hours and 4 days after reinjection of labelled cells. The leukocytes were isolated by a gravity sedimentation method and labelled with In-111 oxinate according to Roevekamp and co-workers. The labelled cell suspension administered to the patient contained between 11 and 15 MegaBq (300-400 microCi). The indium-111 concentration in the liver and spleen was quantitated using a scintillation camera and an on-line computer system. Phantom studies were carried out to obtain conversion factors from geometric mean counts to MegaBq of activity for both liver and spleen. Once determined, the amount of activity in liver and spleen was corrected for physical decay of In-111 and expressed as a percentage of the administered activity. Additionally in the 2nd series ...
International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the absorbed dose in materials with flat or complex ...
Large-scale field tracer experiments have been conducted on Ulchin, Wolsung and Daeduk sites for the purpose of validating FADAS and of analyzing the environmental characteristics around the nuclear sites. The most influential factor in atmospheric dispersion is the meteorological condition. During the experiment, meteorological data were measured on the release point and the selected positions among sampling points. Once radioactive materials are released to the atmosphere, members of public may be exposed through the environmental media such as air, soil and foods. Therefore, to protect the public, adequate countermeasures should be taken at due time for those exposure pathways. both processes, of justification and optimization are applied to a countermeasure simultaneously for decision-making. The work scope of Biological research for the radiation protection had contained the search of biological microanalytic methods ...
The evaluation of biological markers is recognized as necessary to the future of toxicology, epidemiology, and quantitative risk assessment. For biological markers to become widely accepted, their validity...Full Text Available
A number of biological agents are available or being investigated for the treatment of asthma and rhinitis. The safety profiles of these biologic agents, which may modify allergic and immunological...Full Text Available
The introduction of positron emission tomography (PET)/magnetic resonance (MR) systems into medical practice in the foreseeable future may not only lead to a gain in clinical diagnosis compared to PET/computed tomography (CT) imaging due to the superior soft-tissue contrast of the MR technology but can also substantially reduce exposure of patients to ionizing radiation. On the other hand, there are also risks and health effects associated with the use of diagnostic MR devices that have to be considered carefully. This review article summarizes biophysical and biological aspects, which are of relevance for the assessment of health effects related to the exposure of patients to both ionizing radiation in PET and magnetic and electromagnetic fields in MR. On this basis, some considerations concerning the justification and optimization of PET/MR examinations are presented - as far as this is possible at this very early stage. ...
For the purpose of risk estimates from radiation carcinogenesis including leukemogenesis and radiation genetic effects, the biological significant dose is not the tissue kerma in air but the absorbed dose in organ or tissue with respect to carcinogenic and leukemogenic effects or genetic effects. In order to estimate organ or tissue dose from the tissue kerma in air, a ratio of the organ or tissue dose to the tissue kerma in air for survivors in Hiroshima and Nagasaki was calculated with the aid of the Snyder's mathematical phantoms constructed so as to simulate the body shape of survivors aged 5, 10 years old and adult at the time of atomic bomb detonations. The ratios were corrected for the angular distribution of atomic bomb radiations, assuming an anisotropic angular distribution for the survivors exposed to the atomic bombs in open air and the isotropic distribution for the survivors incide a ...
The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product measurement in the dosimetry ...
The volume examines the scientific interfaces and technological applications of physics. Twelve areas are dealt with: biological physics--biophysics, the brain, and theoretical biology; the physics-chemistry interface--instrumentation, surfaces, neutron and synchrotron radiation, polymers, organic electronic materials; materials science; geophysics--tectonics, the atmosphere and oceans, planets, drilling and seismic exploration, and remote sensing; computational physics--complex systems and applications in basic research; mathematics--field theory and chaos; microelectronics--integrated circuits, miniaturization, future trends; optical information technologies--fiber optics and photonics; instrumentation; physics applications to energy needs and the environment; national security--devices, weapons, and arms control; medical physics--radiology, ultrasonics, NMR, and photonics. An executive summary and many chapters contain ...
The overall objective of this project has been to develop immunochemical methods to quantitate unique DNA base damages in order to facilitate studies on radiation-induced damage production and repair. Specifically, we have been using antibodies raised to damaged bases to quantitate unique lesions in model systems in order to evaluate their potential biological consequences. Our approach has been to synthesize modified nucleotides or nucleosides, conjugate them to protein carriers, and use the conjugates as immunogens in rabbits or to prepare monoclonal antibodies. We have been studying damages that are stable radiolysis products found in X-irradiated DNA and thus of potential biological consequence. Our aim is to build an in vitro and in vivo data base on the interactions between model DNA lesions and such cellular enzymes as DNA polymerases and repair endonucleases. Initial studies have focused on pyrimidine ring ...
The overall objective of this project has been to develop immunochemical methods to quantitate unique DNA base damages in order to facilitate studies on radiation-induced damage production and repair. Specifically, we have been using antibodies raised to damaged bases to quantitate unique lesions in model systems in order to evaluate their potential biological consequences. Our approach has been to synthesize modified nucleotides or nucleosides, conjugate them to protein carriers, and use the conjugates as immunogens in rabbits or to prepare monoclonal antibodies. We have been studying damages that are stable radiolysis products found in X-irradiated DNA and thus of potential biological consequence. Our aim is to build an in vitro and in vivo data base on the interactions between model DNA lesions and such cellular enzymes as DNA polymerases and repair endonucleases. Initial studies have focused on pyrimidine ring ...
The operation and proper handling of equipment for measuring EMR-300 electromagnetic waves are studied and apply that knowledge to determine which areas of the metropolitan area are mostly affected by exposure to the emission of radiation. This team is able to measure magnetic field strength, electric field strength and power density, also can measure the most important parameters in a simple manner. International standards provide maximum values for these parameters that limit human exposure to such radiation. These standards are based on epidemiological several and laboratory that have been carried out in order to determine in which circumstances a biological entity is exposed to a level of radiation that can cause harm to their health. It focuses on measuring the level of radiation in certain areas of interest, which were chosen because are areas with high population density and ...
Little clinical evidence has been provided to show the minimization of radiation resistance of tumors using high linear energy transfer radiation. We therefore investigated the radiobiological and molecular pathological aspects of carbon beam therapy. A total of 27 patients with squamous cell carcinoma (SCC) of the cervix were treated using a carbon beam and 50 control patients with SCC of the cervix using a photon beam. The expression of Ki-67, p53, and p27 proteins before radiotherapy and 5 and 15 days after therapy initiation were investigated using immunohistochemistry. Similar changes were observed in Ki-67 labeling index (LI) and p53 LI during carbon and photon beam therapies. However, for carbon beam therapy, the mean p27 LI significantly decreased from 25.2% before treatment to 18.6% on the 5th day after treatment initiation, followed by a significant increase to 36.1% on the 15th day. In contrast, for photon beam therapy, the p27 LI ...
The development of colorimetry and spectroscopy in the nineteenth century is described. An account is given of the application of their techniques to biological chemistry during that period.
Three classes of solar emanations, namely, photon radiation from solar flares, solar energetic particles, and inhomogeneities in the solar wind that drive magnetic storms, are examined, and their effects on humans and technological systems are discussed. Solar flares may disrupt radio communications in the HF and VLF ranges. Energetic particles pose a special hazard at low-earth orbit and above, where they can penetrate barriers such as spacesuits and aluminum and destroy cells and solid state electronics. Energetic solar particles also influence terrestrial radio waves propagating through polar regions. Magnetic storms may disturb the operation of navigation instruments, power lines and pipelines, and satellites; they give rise to ionospheric storms which affect radio communication at all latitudes. There is also a growing body of evidence that changes in the geomagnetic field affect biological systems. 3 refs.
In the Peruvian natural forest there are several kind of woods, some of those are not of commercial interest, because have not resistance at termites and wet, are too soft, or can not be well finished, in the others. The present work is devoted to improvement of the physical properties of wood, such as hardness, traction, wet resistance, etc., by means of the generation of a composite wood-polymers cured by using gamma irradiation. The main objective is to establish the main parameters for the polymerization process (economic technical aspect) that decrease the amount of water absorption, in consequence the volumetric variation of Catahua, Mohena and Capirona woods. Gamma irradiation also provides good protection against the biological agents. In consequence, these woods increase its intrinsic and economic values. (author)
Over the last several years considerable concern has been expressed regarding the potential detrimental effects of radon and radon progeny on our health. The complex nature of the radon decay scheme, which involves the emission of a variety of radiations including several [alpha] particles, [beta] particles, and [gamma]-rays, does not lend itself to clear delineation of the biological effects of the [alpha] particles alone. Polonium-210, the terminal radionuclide of the radon decay series, is useful for this purpose because it has a relatively long shelf-life ([tau][sub 1/2] = 138 d), and it only emits a single 5.3 MeV [alpha] particle in its decay to stable [sup 206]Pb. Accordingly, it has been used extensively in radiobiological studies with incorporated radionuclides. The radionuclide [sup 210]Po is produced in a reactor from [sup 209]Bi. (Author).
The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm{sup -3}, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.
The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm-3, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.
A brief survey is presented of the methods of preparation and of the applications of radiopharmaceuticals labelled with short-lived positron radionuclides "1"1C, "1"8F, "1"3N and "1"5O which, thanks to their energy level schemes, short half-life and the 511 keV photon radiation energy are almost ideal tracers in modern nuclear medicine and pharmacology. In conjunction with computerized tomography, they represent one of the most sensitive diagnostic imaging methods, the so-called positron emission tomography. In addition, their incorporation in the molecule of a pharmaceutical does not change the biological and chemical properties of the original molecule unlike those of radiopharmaceuticals labelled with technetium, iodine, etc. (author). 125 refs.
The authors summarize the significant dose-related effects on brain development which have emerged largely within the last six years of study of prenatally exposed A-bomb survivors. The results are described primarily in terms of the DS86 estimates and differences between these and the older T65DR dose estimates are discussed. The severe mental retardation sample was based on 1598 individuals taken from the PE-86 sample, and the intelligence test scores considered from the same sample involved 1673 children. The authors also discuss some of the recent neurobiological developments that appear relevant to an understanding of the biological bases of dose-related events observed, and suggest future research that may contribute either to further delineation of exposure consequences or to the explanation of the cellular and molecular origins of observed effects. (UK).
The volatility of some elements being determined in biological and environmental samples by NAA (neutron activation analysis) in case of their binding with phenolformaldehyde resin (PFR) is studied. Since the temperature is assumed to influence the volatility of elements stronger than radiation during irradiation of samples in nuclear pile the losses of Se, As, Sb, and Hg form samples on the basis of PFR after their heating at 100-300 deg C have been investigated. It is shown that the losses of Sb and As up to 300 deg C, Se up to 250 deg C, and Hg up to 150 deg C from PFR - based samples do not occur.
The development of 'Green Chemistry' requires new materials to replace the conventional organic chemistry by biological catalysts, to produce fine chemicals in an environmentally friendly manner. Microbial whole cells can be directly used as biocatalysts, providing a simple and cheap methodology since enzyme isolation and purification are avoided. High-density polyethylene (HDPE) is a very stable polymer though it can be activated by gamma radiation to induce grafting. Glycidyl methacrylate was grafted onto macroporous HDPE and PP in the range of 1-6%, proportional to the initial monomer concentration. Grafted polymers were further chemically modified with ethylenediamine to generate a cationic hydrogel of micron-size thickness onto the internal polymer surfaces. Modified polymers were able to immobilize Gram-positive and Gram-negative bacteria that can catalyze a chemical reaction as efficient as free cells do.
Ionizing radiations that differ in number, size, and distribution of energy deposition events might be expected to cause different effects for the same absorbed dose. Furthermore, microdosimetry calculations suggest that large variations in biological effectiveness might be expected for internally deposited alpha-emitting radionuclides for the same absorbed dose, depending upon the specific activity and spatial distribution of the sources in tissue. The study described in this article was designed to demonstrate these phenomena in vitro. Cultured Chinese hamster ovary (CHO-K1 BH4) cells were exposed in vitro to inert, insoluble ceramic microspheres in zirconium dioxide labeled with "2"3"9Pu. The average exit energy of the 5.15 MeV alpha particle was calculated to be 4.3 MeV. Exposure times varied from four to seven hours to achieve the desired dose level.
This work describes the radon in soil gas measurements performed during the last two years in cooperation between the Laboratory of Applied Nuclear Physics of the Federal University of Technology (UTFPR), the Nuclear Technology Development Center (CDTN) and the Institute of Radiation Protection and Dosimetry (IRD) from the Brazilian Nuclear Energy Commission (CNEN). Following previously concluded measurements of radon concentration in dwellings and the measurements of 222Rn activity in drinking water collected at artesian bores of Curitiba urban area, present step of activities has been dedicated to measurements of radon concentration in soil gas. Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specially developed for such measurements Soil Gas Probe through the air pump and filter system. After the Probe was inserted, the ground has been tamped down around the probe, to prevent air from moving ...
Iron is one of the main constituents of stainless steel which is used as a structural material in nuclear reactors. In fast and conceptual fusion and fusion-fission hybrid systems the primary energy range of neutron interaction lies between 1 and 20 MeV which opens up several reaction channels. The reaction cross-sections in this energy range are important for dosimetry, radiation damage, neutronics and safety studies of nuclear reactors. Keeping this in view Nuclear Data Section of the International Atomic Energy Agency has sponsored a Research Co-ordination Programme on Methods for the Calculation of Fast Neutron Nuclear Data for Structural Elements. Under this programme we propose to study (n,n'), (n,2n), (n,3n), (n,p), (n,np), (n,pn), (n,#alpha#), (n,n#alpha#), (n,#alpha#n) and (n,#gamma#) reaction cross-sections. Besides these, total, elastic and discrete level inelastic scattering cross-sections, angular distributions of neutron ...
Brachytherapy refers to short distance treatment of cancer with radiation from small, encapsulated radionuclide sources. This type of treatment is given by placing sources directly into or near the volume to be treated. The dose is then delivered continuously, either over a short period of time (temporary implants) or over the lifetime of the source to a complete decay (permanent implants). This technique is extensively used in the treatments of gynecological, breast, prostate, head and neck, and other soft tissue cancers. The clinical outcomes of this treatment depend on accurate dosimetry and dose delivery. The patient is generally considered to be water equivalent. So the treatment planning system software generally is based on measured or calculated dose distributions in homogenous water medium. In real situation, the treatment volume is not homogenous water medium, but it is a heterogeneous medium consisting of bone, soft tissue, lung, air ...
Full text: Optically stimulated luminescence (OSL) dating of individual sand-sized grains of quartz has advanced significantly over the past decade opening up new vistas in luminescence geochronology. Today, single-grain OSL dating can be used to constrain the burial ages of many deposits, including fluvial sediments, glaciofluvial material and archaeological sediments. It also provides a means of examining the stratigraphic integrity of archaeological sites where sediment mixing might have occurred. An OSL age is calculated by dividing the burial dose (the dose absorbed by the grain since it was last exposed to sunlight) by the environmental dose rate (the rate of supply of ionizing radiation to the grain over the period of burial). To obtain reliable OSL ages, therefore, an accurate estimate of the dose rate is required for each sample. Here we describe our OSL dating campaign at Vindija Cave, a key archaeological site in central Europe that contains a 12 m-thick ...
Several short-lived, high-energy beta emitters are being proposed as the radionuclide components for molecular-targeted potential cancer therapeutic agents. The laboratory mice used to determine the efficacy of these new agents have organs that are relatively small compared to the ranges of these high-energy particles. The dosimetry model developed by Hui et al. was extended to provide realistic beta-dose estimates for organs in mice that received therapeutic radiopharmaceuticals containing 90Y, 188Re, 166Ho, 149Pm, 64Cu, and 177 Lu. Major organs in this model included the liver, spleen, kidneys, lungs, heart, stomach, small and large bowel, thyroid, pancreas, bone, marrow, carcass, and a 0.025-g tumor. The study as reported in this paper verifies their results for 90Y and extends them by using their organ geometry factors combined with newly calculated organ self-absorbed fractions from PEREGRINE and MCNP. PEREGRINE and MCNP agree to within 8% for the worst-case ...
By the use of thermoluminescence (TL) technique we have investigated the effects of gamma irradiation on the TL response of pulverised natural zircon (ZrSiO{sub 4}) crystals from the Jos Plateau area of Nigeria. Samples of the mineral that have been previously annealed were artificially irradiated to moderate gamma doses ranging from 0.7 to 4.9 Gy using {sup 60}Co gamma-source of the CERD. The natural TL glow curve of the sample showed a broad peak around 250 deg. C, the peak was however, found to be completely erased following heat treatment for 2 h at 400 deg. C. The TL glow curves of the artificially irradiated samples showed two overlapping glow peaks at about 112 deg. C (peak I) and at 156 deg. C (peak II) within the dose range utilised. We note that the natural TL peak appears to be different from the two observed in the artificially irradiated sample. The TL response with dose was investigated for the two glow peaks found in the artificially irradiated sample and in both cases, ...
By the use of thermoluminescence (TL) technique we have investigated the effects of gamma irradiation on the TL response of pulverised natural zircon (ZrSiO_4) crystals from the Jos Plateau area of Nigeria. Samples of the mineral that have been previously annealed were artificially irradiated to moderate gamma doses ranging from 0.7 to 4.9 Gy using "6"0Co gamma-source of the CERD. The natural TL glow curve of the sample showed a broad peak around 250 deg. C, the peak was however, found to be completely erased following heat treatment for 2 h at 400 deg. C. The TL glow curves of the artificially irradiated samples showed two overlapping glow peaks at about 112 deg. C (peak I) and at 156 deg. C (peak II) within the dose range utilised. We note that the natural TL peak appears to be different from the two observed in the artificially irradiated sample. The TL response with dose was investigated for the two glow peaks found in the artificially irradiated sample and in both cases, in the ...
Energy and angular double differential cross-section data of fragments by tens of MeV neutron or proton are important to evaluate dosimetry and radiation effect in devices or instruments, since fragments cause a large local ionization. Up to now, experimental data of the fragment production are very scarce due to experimental difficulties of fragment detection. A bragg curve spectrometer (BCS) for fragment measurement is a gridded-ionization chamber that identify fragments on the basis of the difference of Bragg peak value. The BCS was fabricated to adopt for fragment measurement in neutron-induced reactions and tested with a charged-particle beam and then applied to a neutron field successfully. The structure of BCS is a cylindrical gridded ionization chamber, and filled with a Ar + 10% CH{sub 4} gas at a pressure of 2.7 x 10{sup 4} Pa. To confirm the performance of BCS, the following tests were performed: 1) the saturation property by using ...
Brachytherapy is used for treating certain types of cancer by inserting radioactive sources into tumours. CDTN/CNEN is developing brachytherapy seeds to be used mainly in prostate cancer treatment. Dose calculations play a very significant role in the characterization of the developed seeds. The current state-of-the-art of computation dosimetry relies on Monte Carlo methods using, for instance, MCNP codes. However, deterministic calculations have some advantages, as, for example, short computer time to find solutions. This paper presents a software developed to calculate doses in a two-dimensional space surrounding the seed, using a deterministic algorithm. The analysed seeds consist of capsules similar to IMC6711 (OncoSeed), that are commercially available. The exposure rates and absorbed doses are computed using the Sievert integral and the Meisberger third order polynomial, respectively. The software also allows the isodose visualization at the surface plan. The ...
In areas where radiation dose monitoring has not been performed, it is essential to use material available in the environment be able to rapidly assess doses to individuals for immediate emergency medical care or for general estimation of the radiological consequences. It was shown that certain types of telephone cards containing microchips have the potential to be used as individual radiation dosimeters in emergency situations to detect doses over 250 mGy by luminescence measurements. In order to understand the dosimetric properties of chip cards, the components obtained from INFINIEON Company at various stages of production were used for luminescence measurements. It is found that the protecting layer used above the chips so called 'globe top' is the main source of radiation induced signal in chip cards. The globe top produced by INFINIEON at that stage is found to contain SiO2 and Epoxy. In order to improve the ...
In 1978 the Marshall Islands Radiological Safety Program was organized to perform radiation measurements and assess radiation doses for the people of the Bikini, Enewetak, Rongelap and Utirik Atolls. One of the major field components of this program is whole- body counting (WBC). WBC is used to monitor the quantity of gamma- emitting radionuclides present in individuals. A primary objective of the program was to establish {sup 137}Cesium body contents among the Enewetak, Rongelap and Utirik populations. {sup 137}Cs was the only gamma-emitting fission radionuclide detected in the 1,967 persons monitored. {sup 137}Cs body burdens tended to increase with age for both sexes, and were higher in males. The average {sup 137}Cs dose Annual Effective Dose for the three populations was as follows: For Enewetak, the dose was 22{+-}4 {mu}Sv. For Utirik, the dose was 33{+-} 3 {mu}Sv. Since 1985 the Rongelap people have been self-exiled to Mejatto. ...
Upgrading of oil palm empty fruit bunch (EFB), which is a main by-product of palm oil industry, to animal feeds by radiation pasteurization and fermentation was investigated for recycling the agro-resources and reducing the environmental pollution. The following results were obtained: 1) The necessary dose for pasteurization of EFB contaminated by various microorganisms including aflatoxin producing fungi was determined as 10 kGy. The chemical and biological properties of EFB were changed little by irradiation up to 50 kGy. 2) In the fermentation process, Pleurotus sajor-caju was selected as the most effective fungi and the optimum condition for fermentation was clarified. The process of fermentation in suspension was also established for the liquid seed preparation. 3) The digestibility and nutritional value of fermented products were evaluated as ruminant animal feeds and the mushroom can be produced as by-product. 4) The pilot plant named ...
We investigate some aspects of the radiation damage mechanisms in biomolecules, focusing on the modelling of resonant fragmentation caused by the attachment of low-energy electrons (LEEs) initially ejected by biological tissues when exposed to ionizing radiation. Scattering equations are formulated within a symmetry-adapted, single-center expansion of both continuum and bound electrons, and the interaction forces are obtained from a combination of ab initio calculations and a nonempirical model of exchange and correlation effects developed in our group. We present total elastic scattering cross-sections and resonance features obtained for the equilibrium geometries of glycine, alanine, proline and valine. Our results at those geometries of the target molecules are briefly shown to qualitatively explain some of the fragmentation patterns obtained in experiments. We further carry out a one-dimensional (1D) modeling for the ...
To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca{sub 2}SO{sub 4}:Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let spectrum, dose, and dose equivalent from charged particles of ...
This seminar on the subject of ``electrical smog`` welcomed participants from Bavarian environmental consultancy agencies, rural and urban district authorities, ministries, consume-consultancy agencies and public health authorities. Leading scientists from research and authorities gave papers on the sources, exposure and effects/actions of electromagnetic fields and present the current state of knowledge about the hazards and risk of this radiation for human health. The proceedings in hand provide the papers given on the following topics: electromagnetic fields - and introduction to relevant issues; low-frequency fields - sources and exposure; high-frequency fields - sources and exposure; biological actions and effects of low-frequency fields; biological actions and effects of high-frequency fields; low-frequency fields - helath risk assessment; high-frequency fields - health risk assessment. (Uhe) [Deutsch] Das Seminar zum ...
For the study of radiationbiology and its application to radiotherapy, the double differential cross section of electron emission from water vapor induced by 6.0 MeV alpha particle beam is measured. The energy spectra of electrons ranging 7- 10000 eV are detected by the electrostatic analyzer and micro channel plate. The measurements are made at angles between 20 and 160 degrees. With use of this data set, the radial dose distribution in water is calculated by using KURBUC code. It is the Monte Carlo type code of the electron transport process, where the track of the electron is simulated through each individual interactions including elastic scattering, ionization cross section and total excitation cross section in case that electrons with certain energy are put in the liquid-density water. In order to understand the effect of radiation when the particle flux is injected in the human body like radiotherapy using ...
Consensus principles from radiationbiology were used to describe a generic set of nonlinear, first-order differential equations for modeling of toxicity-induced compensatory cell kinetics in terms of sublethal injury, repair, direct killing, killing of cells with unrepaired sublethal injury, and repopulation. This cellular model was linked to a probit model of hematopoietic mortality that describes death from infection and/or hemorrhage between {approximately} 5 and 30 days. Mortality data from 27 experiments with 851 doseresponse groups, in which doses were protracted by rate and/or fractionation, were used to simultaneously estimate all rate constants by maximum-likelihood methods. Data used represented 18,940 test animals distributed according to: (mice, 12,827); (rats, 2,925); (sheep, 1,676); (swine, 829); (dogs, 479); and (burros, 204). Although a long-term, repopulating hematopoietic stem cell is ancestral to all lineages needed to ...
Full text: Thermoluminescence (TL) is a phenomenon of light emission caused by heating a pre-irradiated material. When ionizing radiation hits a TL material, electrons are freed from some atoms and moved in the material, leaving behind 'holes' of positive charge. Subsequently when the TL material is heated, the electrons and the 'holes' re-combine, and release the extra energy in the form of light. The light intensity can be measured, and related to the amount of energy initially absorbed through exposure to the ionizing radiation. In nineteen sixties thermoluminescence dosimeters (TLD) became popular for dosimetric applications in view of their small size, sensitivity and accuracy. Consequently, in early seventies, several countries started adopting of TLD for personnel monitoring. The idea of introducing TLD to replace the then prevalent film dosimeter for personnel monitoring in India was mooted and successfully implemented by Dr. K G Vohra. ...
This is the 1st revision of the INIS/ETDE Joint Thesaurus. It contains 20 953 valid descriptors and 8 600 forbidden terms. It was last updated in December 2003. The Joint Thesaurus contains the controlled terminology for indexing all information within the subject scope of both INIS (International Nuclear Information System) and ETDE (Energy Technology Data Exchange) information systems. The terminology is intended for use in subject description for input or retrieval of information in those systems. The thesaurus is a terminological control device used in translating from the natural language of documents, indexers or users into a more constrained system language It is also a controlled and dynamic vocabulary of semantically and generically related terms which covers a specific domain of knowledge. The domain of knowledge covered by this Thesaurus includes physics (in particular, plasma physics, atomic and molecular physics, and especially nuclear and high-energy physics), chemistry, ...
Objective: To apply the obtained results from 3 stages of research in Chinese radiation protection field. Methods: Based on the identification of physical, chemical and biological qualities for element and its radionuclides under equilibrium condition, main application of these results in Chinese radiation protection field have been discussed by using reported methods in literature. Results: Based on developing elemental reference values of organs or tissues, whole body burdens and their distribution for Chinese Reference Man, discussed in the above 3 articles, current dietary elemental intakes of 42 elements have been updated, and related basis for certain important parameters of bio-kinetic model for use in radiation protection (for example, f_l, T_e and T_b) have been provided. The internal doses from primordial radionuclides and transfer coefficients of elements from environment into the critical ...
Advances in laboratory animal imaging have provided new resources for noninvasive biomedical research. Among these technologies is microcomputed tomography (microCT) which is widely used to obtain high...Full Text Available
A high-purity, intense, fast-neutron source has been developed at our laboratory. We describe two inexpensive, straightforward methods of determining the total number of neutrons produced and we review precautions to be taken in applying these methods. (orig.).
Revised neutron fluence and damage values are reported for the MOTA-2A experiment in the Fast Flux Test Facility (FFTF). This revision corrects an error with processing of the {sup 235}U(n,f) reaction. Net corrections are on the order of 5%.
This report describes a neutron fluence assessment performed for the Kori Unit 3 pressure vessel beltline region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the beltline region of the pressure vessel. After Cycle 16 of reactor operation, 2nd Ex-Vessel Neutron Dosimetry Program was instituted at Kori Unit 3 to provide continuous monitoring of the beltline region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 17
Purposes1. To determine the optimal pelvic nodal clinical target volume for post-operative treatment of endometrial cancer. 2. To compare the DVH of different treatment planning...Full Text Available
There is increasing concern for the potential adverse health effects of human exposures to chemical mixtures. To better understand the complex interactions of chemicals within a mixture, it is essential...Full Text Available
Indoor radon is a potential health hazard for the general public, especially in buildings with poor ventilation. A variety of dosemeters have been developed and used in surveys of radon concentration measurements. In this article the passive dosemeters which are based on solid state nuclear track detectors are reviewed. The principle of passive dosimetry and the factors affecting their performance are discussed. The characteristics of SSNTD materials in relation to their behaviour under different environmental conditions are tabulated and discussed. Results of radon surveys from selected studies are also presented. (Author).
The recent definition of a postulated thermal shock accident followed promptly by system repressurization, termed an overcooling or pressurized thermal shock accident, has set a large analysis and research effort into motion. The essential elements are concerned with defining the accident transients, evaluating the instrumentation and controls that cause the postulated accidents, and evaluating the metallurgical and structural mechanics aspects of the reactor vessel with respect to its failure potential. This paper poses the question faced by the Nuclear Regulatory Commission (NRC) for the vessel steel embrittlement, annealing, and surveillance dosimetry facets of this postulated accident and provides information on our plans for study of this problem as well as current status.
Building on the concepts of MIRD methods described by Webber, Watson and others at this Symposium on the Dosimetry of Administered Radionuclides, we will now consider how to apply these principles to several experimentally based open-quote macroclose quotes and multicellular models. Specifically, methods to calculate absorbed dose using different types of particulate emission (alpha, beta) with a variety of antibody carriers (IgG, F(ab')_2, Fab) for radioimmunotherapy (RIT) will be reviewed. Additionally, a discussion of direct measurement methods at the multicellular level will reveal the problems of tumor absorbed dose heterogeneity when applied to animal and clinical studies.
Background: The difficulty of directly measuring cellular dose is a significant obstacle to application of target tissue dosimetry for nanoparticle and microparticle toxicity assessment. As a consequence, the target tissue paradigm for dosimetry and hazard assessment of nanoparticles has largely been ignored in favor of using metrics of exposure (e.g. ?g particle/mL culture medium, particle surface area/mL, particle number/mL). We have developed a computational model of solution particokinetics (sedimentation, diffusion) and dosimetry for non-interacting spherical particles and their agglomerates in monolayer cell culture systems. Particle transport to cells is calculated by simultaneous solution of Stokes Law (sedimentation) and the Stokes-Einstein equation (diffusion). Results: The In vitro Sedimentation, Diffusion and Dosimetry model (ISDD) was tested against measured transport rates or cellular ...
Comparison of dosimetry measured in a noncylindrical Rando-Alderson phantom by two-field, four-field, and six-field total-skin electron-beam therapy (TSEBT) techniques with our dual-field rotational (DFR) technique reveals a superior dosimetry for the latter. Our technique of dual-field rotational DFR-TSEBT is described in detail, and its advantages and indications for the primary management of cutaneous T-cell lymphoma (CTCL) and Kaposi's sarcoma (KS) are discussed.
The aim of this thesis is the study of new systems devoted to the real time neutron spectrometry and dosimetry. The microelectronics technologies have been used to research a micro system integrating sensor and data processing in real time. The multi range sensor is based on many pair of semiconductor diodes placed face to face and covered by lithium fluoride. The sensor has been designed and its behavior has been simulated. Its operating in reference neutrons beams has been analyzed. (A.L.B.)
Systems biology is a rapidly expanding field that integrates diverse areas of science such as physics, engineering, computer science, mathematics, and biology toward the goal of elucidating the underlying...Full Text Available
...and biological processes acting on recruitment and post-recruitment EU-Agrinet - Project sheet: Biological performance testing methodology to evaluate the durability of plywood as a quality indicator ... Project sheet: Biological performance testing methodology to evaluate the durability of plywood as a quali EU-Agrinet - Project sheet: Genetic evaluation of European ...
Hair is preserved for millennia in permafrost; it enshrines a record of biologic rhythms and offers a glimpse at chronobiology as it was in extinct animals. Here we compare biologic rhythms gleaned...Full Text Available
Iodized oil has been used as a contrast agent in lymphangiography. One of the commercially available compounds is Lipidol Ultra-fluid(LUF) which contains 38% iodine by weight. Nakakuma et al(1979) reported that LUF was selectively retained in the hypervascular hepatocellular carcinoma when injected directly into the ligated hepatic artery. Since that time, it has been widely utilized in the detection as well as the therapeutic attempts of hepatocellular carcinoma, where it has been mixed with chemotherapeutic agents or labeled with radioactive I-131. Like all significant advances, the mechanism of lipid retention within the hepatocellular carcinoma is not clearly understood, and also there is a lack of information about the biodistribution and kinetics of I-131 Lipiodol. The apparent safety of this technique require confirmation. The present study was aimed to assess the biodistribution and kinetics of intraarterially injected I-131 Lipiodol and the histologic changes in canine livers. ...
The authors emphasize the importance of stability in biological standards and discuss the steps taken to ensure the stability of International Standards and the theoretical basis of the various stability...Full Text Available
... L. Sutton. 2000. Is the aquatic weed hygrophila, Hygrophila polysperma (Polemoniales: Acanthaceae), a suitable target for classical biological ... ...
The basic biology of the menstrual cycle is a complex, coordinated sequence of events involving the hypothalamus, anterior pituitary, ovary, and endometrium. The menstrual cycle with all its...Full Text Available
Models can be useful at many different levels when considering complex issues such as biological control of mosquitoes. At an early stage, exploratory models are valuable in exploring the characteristics...Full Text Available
The Liver Carcinogenesis Section uses the modern technologies of molecular biology, cell biology, protein chemistry and genetics to investigate the biochemical and genetic pathways involved in human liver cancer.
Aging is a biological process that affects most cells, organisms and species. Human aging is associated with increased susceptibility to a variety of chronic diseases, including cardiovascular disease,...Full Text Available
Genetics, Genomics, and Molecular Biology USGS scientists develop and integrate new genetic and molecular techniques into systematic analyses to describe individuals and populations of fish .....
In order to consider some procedures to prevent errors in radiotherapy based in learned lessons of accidental expositions and in accordance with information contained in international reports elaborated by International Atomic Energy Agency (IAEA) and of the data base availability by the European group Radiation Oncology Safety Information System (ROSIS) on the events, a research of the occurred errors was performed. For the evaluation of the incidents a data base based in the ROSIS and added plus a parameter was created 'type of error'. All the stored data make possible the evaluation of the 839 incidents in terms of frequency of the type of error, the process of detention, the number of reached patients and the degree of severity. Of the 50 types of found errors, the type of error more frequently was 'incorrect treatment coordinate', confirmed with the data of literature and representing 28,96 por cent of the total of the ...
For the step-and-shoot intensity-modulated radiation therapy (IMRT) technique, the combination of high dose rate, multiple beam segments and low dose per segment can lead to significant differences between the planned dose and the dose delivered to the patient. In this technique, a dose delivery inaccuracy known as the 'overshoot' effect is caused by the dose servo control system. This typically occurs in the first and last beam segments and causes an over- and underdose, respectively. Some dose positional error in the segment sequence is also possible there. Commercial ionization chambers (RK-type) and radiographic Kodak films were used for the measurements. The reported results were obtained using the Pinnacle{sup 3}-V6.2 treatment planning system and a Varian Clinac 21 EX linear accelerator equipped with a 120-leaf Millennium MLC. The dose inaccuracy measurements were based on the comparison of the dose and profiles for reference fields and ...
The DNA double-strand break (DSB) damage response induced by high energy charged particles on lung fibroblast cells embedded in a 3-dimensional (3-D) collagen tissue equivalents was investigated using antibodies to the DNA damage response proteins gamma-histone 2AX (#gamma#-H2AX) and phosphorylated DNA-PKcs (p-DNA-PKcs). 3-D tissue equivalents were irradiated in positions across the linear distribution of the Bragg curve profiles of 307.7 MeV/nucleon, 556.9 MeV/nucleon, or 967.0 MeV/nucleon "5"6Fe ions at a dose of 0.30 Gy. Patterns of discrete DNA damage streaks across nuclei or saturated nuclear damage were observed, with saturated nuclear damage being more predominant as samples were positioned closer to the physical Bragg peak. Quantification of the DNA damage signal intensities at each distance for each of the examined energies revealed a biological Bragg curve profile with a pattern of DNA damage intensity similar to the physical Bragg curve for the ...
A study was conducted to determine the feasibility and the opportunity of photochemical pretreatment on the biodegradation and detoxification of Methyl Tert Butyl Ether (MTBE), Ethyl Tert Butyl Ether (ETBE) and Tert Amyl Methyl Ether (TAME), the most common oxygenates used as octane enhancers in unleaded gasoline. The production, storage, uses and disposal of oxygenates result in an unknown amount of groundwater pollution. Because of their high solubility, MTBE, ETBE and TAME are detected in large portions in saturated zones of aquifers. The biodegradation of these oxygenates is difficult and slow, and information regarding their biodegradability is scarce. Photo-decomposition of oxidants under appropriate UV radiation has been shown to be very effective because the hydroxyl radicals produced possess high oxidation potential. In this study, the H{sub 2}O{sub 2}/UV process was used to generate hydroxyl radicals. Maximal oxygenates transformation was obtained in a ...
A study was conducted to determine the feasibility and the opportunity of photochemical pretreatment on the biodegradation and detoxification of Methyl Tert Butyl Ether (MTBE), Ethyl Tert Butyl Ether (ETBE) and Tert Amyl Methyl Ether (TAME), the most common oxygenates used as octane enhancers in unleaded gasoline. The production, storage, uses and disposal of oxygenates result in an unknown amount of groundwater pollution. Because of their high solubility, MTBE, ETBE and TAME are detected in large portions in saturated zones of aquifers. The biodegradation of these oxygenates is difficult and slow, and information regarding their biodegradability is scarce. Photo-decomposition of oxidants under appropriate UV radiation has been shown to be very effective because the hydroxyl radicals produced possess high oxidation potential. In this study, the H_2O_2/UV process was used to generate hydroxyl radicals. Maximal oxygenates transformation was obtained in a few minutes. ...
Apoptosis is a pattern of cell death involving nuclear pycnosis, cytoplasmic condensation, and karyorrhexis. Apoptosis induced by continuous irradiation with gamma rays (externally given by a 137Cs source) or with beta rays (from tritiated water injected ip) was quantified in the crypts of two portions of mouse bowel, the small intestine and descending colon. The time-course change in the incidence of apoptosis after each type of radiation could be explained on the basis of the innate circadian rhythm of the cells susceptible to apoptotic death and of the excretion of tritiated water (HTO) from the body. For 6-h continuous gamma irradiation at various dose rates (0.6-480 mGy/h) and for 6 h after injection of HTO of various radioactivities (0.15-150 GBq per kg body wt), the relationships between dose and incidence of apoptosis were obtained. Survival curves were then constructed from the curves for dose vs incidence of apoptosis. For the calculation of the absorbed ...
The Synchrotron Resource of the Howard Hughes Medical Institute will be dedicated to structural analyses of biological macromolecules, primarily through crystallography. This facility is under construction at the X4 port of the National Synchrotron Light Source at Brookhaven National Laboratory, and it will comprise three beamlines. The first line to be built has been devised to apply the multiwavelength anomalous diffraction method which provides direct estimates for the phases of reflections. The second line will be devoted to rapid and essentially routine diffraction measurements, mainly through the rotation method. These two experimental stations are contained within refrigerated radiation enclosures that will maintain clean environments, narrowly defined constant temperatures, and protection against biohazard at biosafety level BL-2. At the same time as the second line will be developed, the swath center is planned to first serve as a ...
The present study answers at the request of the Inspection of the classified installations to see the operator of the G.I.P. Cyceron setting up a plan of environmental radiological surveillance around its installations and including, at a minimal level, the following data: Measures of radioactivity on representative biological indicators and measures of dose rate in the environment close to installations in functioning. Further to the radiological assessment of the terrestrial environment of the G.I.P. Cyceron installations realized at the end of 2003, within the framework of a project of the installations extension, the A.C.R.O. was again required for the implementation of this radiological surveillance for year 2005. The first purpose is to supply elements of appreciation about the impact of these installations on environment and persons. This evaluation participates in radiation protection and allows to make sure that the G.I.P. operator ...
Hydrogen cyanide is a key molecule for chemical evolution studies because, when it is exposed to different sources of energy, it forms various compounds of biological importance. To understand the role of minerals in chemical evolution, a series of experiments was performed. First, the adsorption capacity of HCN on different surface minerals was studied; the results show that HCN is readily adsorbed onto the solids proposed (zeolite, serpentine, dolomite, and sodium montmorillonite), in particular zeolite and montmorillonite. Second, the radiolysis of HCN adsorbed on olivine (as an example of a mineral surface) was also followed; it was found that the rate of HCN decomposition by gamma irradiation is enhanced in the presence of the solid. The third series of studies show that organic material was produced in high abundance from HCN at high radiation doses. The radiolytic products included gases (CO_2, NH_4, and CO) and oligomeric materials that ...
A new method is being developed to quickly screen for the human exposure potential to polycyclic aromatic hydrocarbons (PAHs) and organochlorines (OCs). The development involves two key elements: identifying suitable signals that represent intracellular changes that are specific to PAH and OC exposure, and constructing a device to guide the biological cell growth so that signals from individual cells are consistent and reproducible. We are completing the identification of suitable signals by using synchrotron radiation-based (SR) Fourier-transform infrared (FTIR) spectromicroscopy in the mid-infrared region (4000-400 cm-1). Distinct changes have been observed in the IR spectra after treatment of human cells in culture medium with PAHs and OCs. The potential use of this method for detecting exposure to PAHs and OCs has been tested and compared to a reverse transcription polymerase chain reaction (RT-PCR) assay that quantifies increased ...
Awaiting new data from RERF, an attempt was made to estimate the somatic risks of low doses of radiation for members of the German public. The new estimate follows closely the approach used in deriving the values published in the NIH Radioepidemiological Tables. The lifetime risk factors thus calculated are significantly larger than the estimates presented in ICRP Report 26 and are consistent with estimates recently made in the ongoing reactor safety study of NUREG. The increase in lifetime risks is mainly due to the introduction of a new time projection model which appears to be more consistent with the epidemiological data for many late effect end points than the constant absolute risk model previously employed. Results from a study in which epidemiological data were stochastically simulated with a computer indicate that the shapes of actual dose effect curves might be significantly more influenced by pure chance than by the dose dependency of underlying ...
The influence of low-level microwaves (2.45 GHz, CW, 2 and 5 mW.cm/sup -2/) was studied on various models of previsional animal psychopharmacology involving tests of motor activity, stereotypy, convulsions and hypothermia after a standard 30 min irradiation. The results obtained on 933 rodents allow to conclude that: (1) there is no interaction between microwaves and the studied convulsants and stimulants; (2) there is a possibility of potentialization of the behavioral effects of a tranquilizer; (3) there is a thermogenic effect of microwaves; (4) there is no change of the blood-brain barrier permeability. The demonstration of a thermal effect of microwaves during radiations lower than 10 mW.cm/sup -2/ the safety threshold admitted presently (a value below which the exposure duration comes under regulation) could explain the energetic nature of certain effects of microwaves up-to-now described as non-thermal.
Sodium-dependent high-affinity choline uptake was measured in the striatum, frontal cortex, hippocampus, and hypothalamus of rats after acute exposure (45 min) to pulsed (2 microseconds, 500 pps) or continuous-wave 2,450-MHz microwaves in cylindrical waveguides or miniature anechoic chambers. In all exposure conditions, the average whole-body specific absorption rate was at 0.6 W/kg. Decrease in choline uptake was observed in the frontal cortex after microwave exposure in all of the above irradiation conditions. Regardless of the exposure system used, hippocampal choline uptake was decreased after exposure to pulsed but not continuous-wave microwaves. Striatal choline uptake was decreased after exposure to either pulsed or continuous-wave microwaves in the miniature anechoic chamber. No significant change in hypothalamic choline uptake was observed under any of the exposure conditions studied. We conclude that depending on the parameters of the radiation, ...
-Ecophysiological and floristic study of the lichen communities in .... Plasticity of the Lichen Catillaria corymbosa in Different Microhabitats of the ...
This is the second revision of the ETDE/INIS Joint Thesaurus, including all updates up to September 2006. It contains 21 147 valid descriptors and 9 114 forbidden terms. The Joint Thesaurus contains the controlled terminology for indexing all information within the subject scopes of the International Nuclear Information System (INIS) and the Energy Technology Data Exchange (ETDE). The terminology is intended for use in subject descriptions for input or retrieval of information in these systems. The thesaurus is a terminological control device used in translating from the natural language of documents, indexers or users into a more constrained system language It is also a controlled and dynamic vocabulary of semantically and generically related terms which covers a specific domain of knowledge. The basic terminology in this thesaurus goes back to the 1969 edition of the EURATOM Thesaurus. The structure subsequently given to that terminology was the result of a systematic study performed ...
The aim of our experiment was the testing of effects of common ammunition on usable and slightly accessible biological tissue thereby to create fundamental simple biological model for trials of wounded ballistic. Like objective tissue was elected biological material - pork and beef hind-limbs, pork head, pork bodily cavity. It was discovered that objective tissue is able to react to singles types of shots in all spectrum results namely simple smooth penetration wound as well as splintery fracture in dependence on kind of using ammunition. Pork hind-limb was evaluated like the most suitable biological material for given object. PMID:17172163
A computer-based beam dosimetry measurement system for boron neutron capture therapy provides accurate, sensitive, and rapid readout and recording of all beam dose components, epithermal and thermal neutron flux, and gamma-ray dose rate. This dosimetric system includes input from the characterization of the epithermal neutron beam developed at the Massachusetts Institute of Technology, actual BPA pharmacokinetic data from a specific human subject being irradiated, output of MacNCTPLAN, a treatment planning system developed by the authors group, and input from the five on-line beam detectors. The purpose of this system and associated readout systems is to ensure that the desired dose is delivered to the subject within acceptable dose tolerances, e.g., {+-}5% of the target dose, and that any perturbations in the neutron beam that may occur during irradiation can be rapidly evaluated and the appropriate measures taken.
A computer-based beam dosimetry measurement system for boron neutron capture therapy provides accurate, sensitive, and rapid readout and recording of all beam dose components, epithermal and thermal neutron flux, and gamma-ray dose rate. This dosimetric system includes input from the characterization of the epithermal neutron beam developed at the Massachusetts Institute of Technology, actual BPA pharmacokinetic data from a specific human subject being irradiated, output of MacNCTPLAN, a treatment planning system developed by the authors group, and input from the five on-line beam detectors. The purpose of this system and associated readout systems is to ensure that the desired dose is delivered to the subject within acceptable dose tolerances, e.g., #+-#5% of the target dose, and that any perturbations in the neutron beam that may occur during irradiation can be rapidly evaluated and the appropriate measures taken.
A tissue-equivalent dosimetry system has been developed for use in absorbed dose determinations with physical models of Reference Man. The dosimeter used was a thermo-luminescent dosimeter (TLD) powder which was mixed with a 'tissue-equivalent' material and modeled to closely approximate an organ's geometry and absorption properties. A separation procedure was developed by which the TLD powder was washed and the 'tissue-equivalent' material, a wax, was dissolved and extracted following the irradiation of the model. The procedure was tested to determine losses of powder, homogeneity of the powder's distribution throughout the wax, the effects of the separation procedure upon the powder and the statistical behavior of the procedure. The results of these tests established the feasibility of the procedure. A full-scale model of the pancreas was tested and the results supported the validity of the technique. (author)
Background: EGFR (epidermal growth factor receptor) and VEGF (vascular endothelial growth factor) inhibitors confer clinical benefit in metastatic colorectal cancer when combined with chemotherapy. An emerging strategy to improve outcomes in rectal cancer is to integrate biologically active, targeted agents as triple therapy into chemoradiation protocols. Material and methods: cetuximab and bevacizumab have now been incorporated into phase I-II studies of preoperative chemoradiation therapy (CRT) for rectal cancer. The rationale of these combinations, early efficacy and toxicity data, and possible molecular predictors for tumor response are reviewed. Computerized bibliographic searches of Pubmed were supplemented with hand searches of reference lists and abstracts of ASCO and ASTRO meetings. Results: the combination of cetuximab and CRT can be safely applied without dose compromises of the respective treatment components. Disappointingly low rates of pathologic ...
Present and potential future changes to the global environment have important implications for marine pollution and for the air-sea exchange of both anthropogenic and natural substances. This report addresses three issues related to the potential impact of global change on the air-sea exchange of chemicals: Global change and the air-sea transfer of the nutrients nitrogen and iron. Global change and the air-sea exchange of gases. Oceanic responses to radiative and oxidative changes in the atmosphere. The deposition of atmospheric anthropogenic nitrogen has probably increased biological productivity in coastal regions along many continental margins. Atmospheric deposition of new nitrogen may also have increased productivity somewhat in mid-ocean regions. The projected future increases of nitrogen oxide emissions from Asia, Africa and South America will provide significant increases in the rate of deposition of oxidized nitrogen to the central ...
Irradiation is efficient at extinction fungi contamination in peanuts. Peanuts have high biologic value protein, minerals, vitamin E, complex B, and high concentration of lipids. The objective of this research is to evaluate the gamma irradiation effect on color, total phenolic, antioxidant activity, and fatty acid profile in peanuts (Arachis hypogaea L.). Cultivars IAC-Tatu ST and IAC-Runner 886 were submitted to gamma radiation with doses of 5.0; 7.5; 10.0, and 15.0 kGy and storage at room temperature. There was no significant difference in the color of IAC-Tatu ST. However, significant difference was found in the luminosity and Chroma in IAC-Runner 886. Total fenolics differed from the control with 33.27 mg.g-1 and treatment dose of 10.0 kGy with 58.60 mg.g-1 in IAC-Tatu ST. This parameter not had significant difference in IAC-Runner 886 and the control with 51.59 mg.g-1. The antioxidant activity did not present significant difference with a ...
Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available
... radiation during clinical therapy and exposures due to radiation accidents or attacks, in which the doses are uncontrolled ... only be used off-label in victims of radiation accidents or attacks. The idea...
Understanding the dependence and interplay between architecture and function in biological networks has great relevance to disease progression, biological fabrication and biological systems in general. Recent research in complex systems and networks, presents methods to properly mine the architectural interdependence in networks. Guided by such work, we propose methods to associate organism characteristics with network topology by analyzing a large number of architectural patterns. We adopt an automated approach using 11 topological metrics from complex networks to characterize a collection of various kinds of biological networks. Principal component analysis and clustering allow us to extract the indispensable, independent and informative metrics. Using hierarchical linear modeling, we observe that organism characteristics associate with these metrics, surprisingly well. This work can serve as a ...
This paper describes the structure of dynamic neuronal ensembles (DNEs). DNEs represent a new paradigm for learning, based on biological neural networks that use variable structures. We present a computational neural element that demonstrates biological neuron functionality such as neurotransmitter feedback absolute refractory period and multiple output potentials. More specifically, we will develop a network of neural elements that have the ability to dynamically strengthen, weaken, add and remove interconnections. We demonstrate that the DNE is capable of performing dynamic modifications to neuron connections and exhibiting biological neuron functionality. In addition to its applications for learning, DNEs provide an excellent environment for testing and analysis of biological neural systems. An example of habituation and hyper-sensitization in biological systems, using a neural ...
Fiber optic metrology developed at the CEA LIST laboratories involves fiber Bragg grating sensors, distributed Brillouin optical time domain reflectometry and optically stimulated luminescence dosimetry. Recent activities in optical fiber sensing are reviewed from laboratory experiments to field trials.
Thermoluminescence (TL) and Electron Paramagnetic Resonance (EPR) dosimetry were used to measure dose effects in borosilicate glass with time, from 10 minutes to #approx#60 days following exposure to a dose of up to 10,000 Rad. TL and EPR results were consistent and performed similarly, with both techniques capable of achieving an estimated limit of detection of between 50-100 Rad. Three peaks were identified in the TL glow curve at roughly 110 C, 205 C, and 225 C. The intensity of the 205 C peak was the dominant peak over the time period of this study. The stability of all of the peaks with time since irradiation increased with their corresponding temperature and little or no variation was observed in the glow curve response to a specified total dose attained at different dose rates. The intensity of the 205 C peak decreased logarithmically with time regardless of total dose. Based upon a conservative limit of detection of 330 Rad, a 10,000 Rad dose would still be ...
Electron spin resonance (ESR) dosimetry of irradiated chicken legs is based on the additive dose or the calibration curve methods. In both cases the practical assumption is made that the behaviour of the chicken bone does not depend on factors such as temperature during irradiation, storage conditions and dose rate. So the aim of the present work was to investigate to what extent the above mentioned factors could influence the post-irradiation dose assessment using the ESR technique. (author).
This report summarizes the activities and major accomplishments for the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2002. Topics covered include computational dosimetry and treatment planning software development, medical neutron source development and characterization, and boron analytical chemistry.
This report summarizes the activities and major accomplishments for the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2002. Topics covered include computational dosimetry and treatment planning software development, medical neutron source development and characterization, and boron analytical chemistry.
A short synopsis of each project is given covering the following main areas of research and development: Atmospheric sciences; Biotechnology; Chemical and instrumentation analysis; Computer and information science; Design and manufacture engineering; Ecological science; Electronics and sensors; Experimental technology; Health protection and dosimetry; Hydrologic and geologic science; Marine sciences; Materials science; Nuclear science and engineering; Process science and engineering; Sociotechnical systems analysis; Statistics and applied mathematics; and Thermal and energy systems.
The study compares the doses absorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations.
The aim of this study is to compare the dosimetry results that are obtained by using Convolution, Superposition and Fast Superposition algorithms in Conventional Radiotherapy, Three-Dimensional Conformal...Full Text Available
Helical tomotherapy presented many unique dosimetric challenges and solutions during the initial commissioning process, and some of them are presented. The dose calculation algorithm is convolution/superposition based. This requires that the energy fluence spectrum and magnitude be quantified. The methodology for doing so is described. Aspects of the energy fluence characterization that are unique to tomotherapy are highlighted. Many beam characteristics can be measured automatically by an included megavoltage computed tomography imaging system. This greatly improves data collection efficiency.
The Fast Flux Test Facility (FFTF) reactor characterization by the Hanford Engineering Development Laboratory (HEDL) includes extensive neutronic measurements during startup and initial operation. To aid in the handling and counting of the thousands of passive dosimeters used as part of this effort, an automated dosimetry specimen handling, positioning, and counting system was designed and developed by Westinghouse Hanford for the Department of Energy.
The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)
One of the refinements of modern Nuclear Medicine is the capacity of providing dynamic and kinetics images of the administered radiopharmaceutical, reproducing its transport mechanism, action sites, receptor binding and excretion route. With the continues technological advances new radiopharmaceuticals have been developed in order to express higher specificity and with higher characters of affinity between receptor/complex. One radiopharmaceutical is formed by a reagent or bio molecule that has in its structure a radioisotope, that has the objectives of carrying it to the organs of affinity or to benign or malign tumoral process. Somatostatin inhibits the growing and proliferation of several tumoral cells. Somatostatin analogs bind to somatostatic receptors that are expressed in different kind of neoplasia DOTA-LANREOTIDE (DOTALAN) is an octapeptide analog to somatostatin. The interest of labeling the bio conjugate with gallium-67 in Nuclear Medicine comes from its physical, chemical ...
BackgroundPCR amplification for the detection of pathogens in biological material is generally considered a rapid and informative diagnostic technique. Invasive Salmonella...Full Text Available
Early on, intriguing biological activities were found associated with the EETs using in vitro systems. Although the EETs other than the 5,6-isomer, are quite stable chemically,...Full Text Available
... biological effects of electromagnetic fields (EMFs) produced by high-voltage transmission lines have come under intense scrutiny, mostly with respect ... biological effects of electromagnetic fields (EMFs...
In this study, we report the physico-chemical and biological properties of a novel biodegradable composite scaffold made of nano-hydroxyapatite and natural derived polymers of chitosan and carboxymethyl...Full Text Available
Cleavage of membrane-associated proteins with the release of biologically active macromolecules is an emerging theme in biology. However, little is known about the nature and regulation of the involved...Full Text Available
The polarity of biological mediums controls a host of physiological processes such as digestion, signaling, transportation, metabolism, and excretion. With the recent widespread use of near-infrared...Full Text Available
The plasma metabolic clearance of biologically active luteinizing hormone (bioactive LH) was studied using the rat interstitial cell testosterone (RICT) bioassay in six hypogonadotropic men after single...Full Text Available
The effective population size (Ne) is an important parameter in ecology, evolutionary biology and conservation biology. It is, however, notoriously difficult to estimate,...Full Text Available
This study compared the effectiveness of collaborative group composition and instructional method on reasoning gains and achievement in college biology. Based on initial student reasoning ability (i.e.,...Full Text Available
AbstractThree biologic dressings [split-thickness allogeneic skin (STS)], allogeneic peritoneum (P), and xenogenic porcine small intestinal submucosa (PSIS)] were...Full Text Available
CF-23“The biggest stumbling block for biological sciences turned out to be synthetic organic chemistry” – Elias A. Zerhouni, Former NIH Director in Chemical...Full Text Available
The consequences of structural modifications at the 5'-OH ribofuranotide moiety of quinoline modified B12 derivatives are discussed in regard of the coordination chemistry, the electrochemical properties and the biological behaviour of the compound. PMID:21850334
One of the central questions of molecular biology is the discovery of the semantics of DNA. This discovery relies in a critical way on a variety of expensive computations. In order to solve these computations, both parallel computers and special-purpose hardware play a major role.
We review the application of C. elegans as a model system to understand key aspects of stem cell biology. The only bona fide stem cells in C. elegans...Full Text Available
Current pesticide health risk assessments in the United States require the characterization of aggregate exposure and cumulative risk in the setting of food tolerances. Biologic monitoring can aggregate...Full Text Available
Consistent holistic view of sexual species as the highest form of biological existence is presented. The Weismann's idea that sex and recombination provide the variation for the natural...Full Text Available
BackgroundNetwork visualization would serve as a useful first step for analysis. However, current graph layout algorithms for biological pathways are insensitive to biologically...Full Text Available
This article reports on a one-semester Advanced Cell Biology course that endeavors to bridge the gap between gaining basic textbook knowledge about cell biology and learning to think and work as a researcher....Full Text Available
... A Rapid Biological Assessment of the Kaijende Highlands, Enga Province, Papua New Guinea. RAP Bulletin of Biological ... A Rapid Biodiversity Assessment of the Kaijende Highlands, Enga Province, Papua New...
The case of spontaneous radiation of channeled ultrarelativistic particles is considered when the dipolarity condition is not satisfied. The change of the particle longitudinal velocity affecting the maximum radiation frequency is included. The angular and frequency characteristics of the radiation for superhigh energies are studied for the first time. It is shown that there is an optimum energy at which the radiation density is maximum. The influence of the angle at which electrons enter a crystal and of the beam divergence on the radiation is investigated. The problem of quasichanneled particle radiation and also the radiation in axis-plane transitions are considered. (author).
The term biological motion is often used by researchers studying the patterns of movement generated by living forms and in sports. We studied a pattern recognition system of motion in sport using biological motion data. Biological motion data are acquired using a 3D motion capture system. However, 3D motion capture systems are very expensive. In this article, a biological motion capture system was built using acceleration sensors. Our proposed system uses the technique of Gaussian fitting and regression analysis. We tested our proposed system in pattern recognition of outdoor tennis and its evaluations.
Systematics of neutron capture radiative width were studied in the target element range from Th to Cm. Reduced radiative widths were analyzed with a simple radiative width formula based on E1 transition. Average radiative width is presented with the standard deviation of 15%. (author)
The loss of lead in various kinds of biological materials after drying and ashing is studied by using "2"0"3Pb as tracer which is intravenously injected into mice. The experimental results show that although the oven ashing can be used for determining the lead in samples of lung, kidney, and liver, etc., the oxygen plasma and high pressure digestion are the most suitable methods for the determination of lead in biological materials. (author) 5 refs.; 2 tabs.
Biological motors generally fall into two categories: (1) those that convert chemical into mechanical energy via hydrolysis of a nucleoside triphosphate, usually adenosine triphosphate, regarded as life's chemical currency of energy and (2) membrane bound motors driven directly by an ion gradient and/or membrane potential. Here we argue that electrostatic interactions play a vital role for both types of motors and, therefore, the tools of physics can greatly contribute to understanding biological motors.
This meeting focussed on the study of the structure and dynamics of biological molecules, with particular emphasis on neutron and complementary methods as well as related enabling technologies. The program covered biological problems that are being addressed by neutron scattering and those where there is the potential to do so in the future. This document provides the abstracts of the different presentations. (A.L.B.)
The mechanisms underlying life machinery are still not completely understood. Something is known, something is ?probably? known, other things are still unknown. Scientists all over the world are working very hard to clarify the processes regulating the cell life cycle and bioinformaticians try to support them by developing specialized automated tools. Within the plethora of applications devoted to the study of life mechanisms, tools for the analysis and comparison of biological networks are catching the attention of many researchers. It is interesting to investigate why.
Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)
Metabolic profile is an important biological marker of neoplastic processes not only in the tumor itself but also in the host organism. The neuro-hormone melatonin has been implicated in the experiments as an oncostatic agent. Female Wistar:Han SPF rats (Velaz, Prague, Czech Republic) were irradiated continuously for 15 days using a daily gamma rays dose of 96 mGy. At the end of exposure one group of rats was administered 5 mg/kg b.w. of dimethylbenz/a/anthracene (DMBA) intragastrically. During the period of exposure to ionizing radiation a part of the animals was supplied with melatonin (M) at a concentration of 20 #mu#l/ml in drinking water. Selected parameters of lipid and carbohydrate metabolism and levels of selected hormones were determined 2, 30 and 100 days post-irradiation. The irradiation itself caused only small changes in tissue lipids. The application of a single low dose (subthreshold from the point of view of induction of mammary ...
Analysis by gas chromatography-mass spectrometry and high performance liquid chromatography has revealed organic residues in sup(99m)Tc-pertechnetate obtained from "9"9Mo-molybdate by extraction, using the organic solvent methylethylketone (MEK). The organic residues have been identified as either (i) low molecular weight carbonyl compounds such as formaldehyde, acetaldehyde and acetone, presumably caused by the effects of #gamma#-radiation on MEK, or (ii) condensation products resulting from the action of strong alkali on MEK during the extraction process. The quantities of organic residues varied from batch to batch of extracted pertechnetate; up to 40 #mu# mL"-"1 was found. When these compounds were tested, in rats, by addition to a pyrophosphate bone-seeking radiopharmaceutical, the tissue distribution was not significantly different from that in the control, which contained no added compound. Assay for "9"9Tc in MEK-derived pertechnetate indicated up to 10 ...
In radiation therapy with hadron beams, conformal irradiation to a tumour can be achieved by using the properties of incident ions such as the high dose concentration around the Bragg peak. For the effective utilization of such properties, it is necessary to evaluate the volume irradiated with hadron beams and the deposited dose distribution in a patient's body. Several methods have been proposed for this purpose, one of which uses the positron emitters generated through fragmentation reactions between incident ions and target nuclei. In the previous paper, we showed that the maximum likelihood estimation (MLE) method could be applicable to the estimation of beam end-point from the measured positron emitting activity distribution for mono-energetic beam irradiations. In a practical treatment, a spread-out Bragg peak (SOBP) beam is used to achieve a uniform biological dose distribution in the whole target volume. Therefore, in the ...
This Report of activity displays the work developed at Centre d`Etude Nucleaires de Bordeaux-Gradignan (CENBG) in the period 1995-1996. A number of 68 short progress notes are presented in the fields of Cosmic particles (3), Nuclear Astrophysics (4), High Spins-Large Deformations (8), Basic Interactions (9), Exotic Nuclei (10), Hybrid Systems (4), Theoretical Physics (28), Cellular Microanalysis by means of Nuclear Probes (3) and Technical Development (3). The main problems attacked at CENBG, established as orientations by scientific board of IN2P3 (CENBG is a UMR of Bordeaux-1 Univ. and CNRS-IN2P3) are the following: the research of Majorana/Dirac nature of neutrino (in the framework of NEMO Experiment) in relation with the problem of origin of mass in the Universe and the cosmological puzzle of dark matter, the investigation of the origin of high energy (20 to 200 GeV) cosmic radiation (in the framework of CELESTE Experiment), the study of extreme issues in ...
Purpose: The aim of this study was to create, perfect and test a hyperthermia balloon catheter for local treatment of cholangiocarcinoma. The device should induce hyperthermia in tumor tissue by acting locally in the bile duct lumen in contact with the tumor-infiltrated duct wall. In addition, it should exert tissue compression to cause an appreciable reduction in tumor microvasculature flow, thus improving thermal performance. Methods: According to the design specifications, the working temperature range should allow the device to be used for hyperthermia therapy either in combination with radiation and/or chemotherapy(radio/chemo-sensitizing effect at 42-45 deg. C) or alone (induction of coagulation necrosis above 65 deg. C). The balloon serves as an anchoring system during treatment and as a functional element to induce tissue compression. In vitro mechanical evaluation of the pressure/volume relationship, with the balloon inside rigid walled conduits, was ...
Combination of radiotherapy and chemotherapy (CRC) is actually one important way of research in oncology. Theoretical advantages are: (1) Spatial cooperation; (2) Additivity, which is only obtained if the toxicity of each modality are different; (3) Supra-additivity, which needs a rigorous in vitro definition; the only way to prove it is to make an isobologram analysis. This model has however, some limitations: qualitative variable could not be used, results could be different, depending on the cell line and isoeffect chosen...In fact, a supra-additivity was only demonstrated for cis platinum and etoposide. Interactions mechanisms were: (1) at the molecular level, creation of new lesions or inhibition of radiation lesions repair; (2) At the cellular level, either cytokinetic cooperation with S-phase dependent drugs, or synchronization for the drugs which blocked the cells in M-phase; (3) At the tissular level, reoxygenation, cycle redistribution. In clinical ...
German translation of the publication 'The evaluation of risks from radiation' published in 1965 by the International Commission on Radiological Protection. In a survey, genetic and somatic risks from radiation are presented and explained. (HP).
The CPHR individual monitoring service acquired an automatic RADOS TLD system to improve its capacities to satisfy the increasing needs of their national customers. The TLD system consists of: two automatic TLD reader, model DOSACUS, a TLD irradiator and personal dosimeters card including slide and holders. The dosimeters were composed by this personal dosimeters card and LiF:Mg,Cu,P (model GR-200) detectors. These readers provide to detectors a constant temperature readout cycle using hot nitrogen gas. In order to evaluate the performance characteristics of the system, different performance tests recommended by the IEC 1066 standard were carried out. Important dosimetric characteristics evaluated were batch homogeneity, reproducibility, detection threshold, energy dependence, residual signal and fading. The results of the tests showed good performance characteristics of the system. (Author)
The suitability of calcium silicate bricks (CSBs) for the retrospective measurement of gamma dose using luminescence techniques has been investigated. Bricks of this type are distinguished from fired clay bricks by containing negligible clay and requiring comparatively low temperature treatment during manufacture. They have been used widely in the construction f buildings in the Former Soviet Union since the 1970s but hitherto have not been used for retrospective dosimetry measurements. A procedure based on the se of the 210 deg. C thermoluminescence (TL) peak of quartz was tested with granular quartz extracted from three types of CSB, one of which had been taken from a settlement downwind of Chernobyl. The degree to which the residual geological TL signal within the temperature range of the 210 deg. C L peak had been reduced during manufacture varied with brick type; the levels of residual TL corresponded, in the samples tested, to absorbed doses n the range ...
Measurements were carried out for calibration and performance testing of a set of 10 electronic personal dosimeters (EPDs) at the Secondary Standard Dosimetry Laboratory of Sudan. Calibrations were carried out at three X-ray beam qualities described in ISO standard 4037 in addition to 137Cs and 60Co gamma ray beams. The experimental was performed with EPDs mounted on ICRU Slab phantom. X-ray and ?-ray beams were characterized in terms of air kerma free-in-air which were converted to the known delivered personal dose equivalent, Hp(10) using appropriate the air kerma to personal dose equivalent conversion coefficients. Dosimeters tested showed excellent energy and angular response and relative error of indication within the recommended limit for photon energies from 65 keV to 1.25 MeV. The study showed encouraging results for using electronic dosimeters in personal dosimetry.
The study had three objectives: to collect information that explain the impact of the Aube storage center (C.S.A.) on environment and allow to evaluate the consequences for man, secondly, to build a referential for any future inquiry or follow-up, thirdly, to allow to the local commission of information to elaborate an information towards the side residents and local actors that take into account their questions. Trees, waters, sediments, soils, grass, products of gardens and vineyards were the object of sampling, their dosimetry is given in this report. Other dosimetry measures were made along the nuclear site and the results are equally in this report. (N.C.)
Organ and tissue doses and integral doses in patients due to diagnostic x-ray examinations of the chest and of the head will be presented. These data have been obtained by measuring the dose distributions in man phantoms by LiF-dosimetry. The data will be compared with data obtained by Monte-Carlo calculations. To obtain average organ doses for a special type of examination for the population or for a specified subpopulation in the variation of the exposure, data due to the different techniques used by the different radiologists has to be known. Such data will be presented. The results of the investigation will be discussed in connection with the concept of the 'somatic significant.
Nuclear forensics is the analysis of nuclear materials recovered from either the capture of unused materials, or from the radioactive debris following a nuclear explosion and can contribute significantly to the identification of the sources of the materials and the industrial processes used to obtain them. In the case of an explosion, nuclear forensics can also reconstruct key features of the nuclear device. Nuclear forensic analysis works best in conjunction with other law enforcement, radiological protection dosimetry, traditional forensics, and intelligence work to provide the basis for attributing the materials and/or nuclear device to its originators. Nuclear forensics is a piece of the overall attribution process, not a stand-alone activity
A simple method for preparing LiCaAlF6:Eu2+ phosphor is reported. Photoluminescence (PL) and thermoluminescence (TL) studies were carried out. The TL sensitivity of the phosphor is nearly twice that of CaSO4:Dy TLD phosphor. Several other properties required for TL dosimetry are superior as well. It is suggested that the phosphor can be a suitable replacement for CaSO4:Dy. (Copyright 2007 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim)
A 2D matrix allows a fairly rapid verification of irradiation parameters transferred on computer processing equipment without expanding the dosimetry means to implement. Associated to 'Multicheck and Verisoft' software it will handle some of the regulatory recommendations of the A.F.S.S.A.P.S. for quality control of accelerators and ensure the traceability of testing carried out. (N.C.)
Subject to the provisions of the Radiation Protection Act, the Authority, on the advice of ...(f) in collaboration with the Radiation Protection Board, conduct an ionising radiation monitoring programme and ...or document kept under the control of the Radiation Protection Board.
Described and discussed in this paper are radiation processes and their advantages over the conventional techniques. Radiation sterilization of medical products, food irradiation, wood plastic composites, and radiation treatment of sewage and waste waters are presented. The Philippine experience in using these technologies, its problems and barriers are also given. (ELC).
The rapid growth in the use of in vitro methods for nanoparticle toxicity assessment has proceeded with limited consideration of the unique kinetics of these materials in solution. Particles in general and nanoparticles specifically, diffuse, settle and agglomerate in cell culture media as a function of several systemic and particle factors: media density and viscosity, particle size, shape and density. Cellular dose then is also a function of these factors as they determine the rate of transport of nanoparticles to cells in culture. Here we develop and apply the principles of particokinetics and dosimetry in vitro and outline an approach for simulation of nanoparticle particokinetics in cell culture systems. We illustrate that where equal mass concentrations (?g/ml) imply equal doses for dissimilar materials, the corresponding particle number or surface area concentration doses differ by orders of magnitude. When rates of diffusional and gravitational particle ...
Values of the chemical yield, G, and of the molar extinction coefficient, epsilon, for Fricke dosimetry, have been recommended by ICRU. For epsilon, the value in ICRU Reports 17 and 21, 2205 1.mol"-"1.cm"-"1, based on an analysis of 83 reported values. It was suggested that, where neither a careful wavelength calibration nor absorbance linearity checks had been performed, a standard error of 1.5% should be assumed; otherwise 0.15% could be accepted. Alternatively, the accuracy in applying this chemical dose meter was considered improved if there was an independent determination of epsilon with the same spectrophotometer as was used for the determination of the optical density of irradiated Fricke solution. The accuracy claimed for both methods remains questionable, since no complete argumentation could be given for the differences of up to 13% in the published values. Taking into account the discussion of the sources of error by Bryant, Broszkiewicz and Ellis, we ...
... Radiation Protection Products and Equipment Find and compare a variety of radiation protection products and equipment on the world's largest environmental industry portal. View product ...
The ''biotechnology 2000'' project is supervised by the project sponsor ''biology, energy, ecology'' at Forschungszentrum Juelich on behalf of the Federal Ministry for Research and Technology. The project activities cover the development of techniques and methods, cell biology, gene structure and gene regulation, photosynthetic production processes, biological hydrogen production, synthetic biology, protein design, neurobiological research, biosystems, plant breeding, phytomedicine and plant protection, the biology of waste disposal methods, research into methods which replace animal experiments, biological safety research, technology risk assessment, and ethical aspects. A general survey introduces the promoted projects, and standardized data sheets briefly introduce the individual ...
This chapter is concerned with standards and guidances for limiting radiation exposures. It is divided into three sections, each of which has several parts. Section 1: Ionizing Radiation -- Standards and Guidances Applicable to the Public: Part A, Radiation Protection Standards; Part B, Environmental Radiation Standards; Part C, Exempt Levels of Radioactivity; Part D, Protective Action Guides for Accidents. Section 2: Ionizing Radiation -- Standards Applicable to the Workplace. Section 3: Medical and Other Standards.
On the basis of legally provided area dose measurements and time records of fluoroscopic examinations during the operation, radiation doses to medical personnel and patients are evaluated. Adequate radiation protection measures and a careful behaviour in the operating room keep the radiation exposure to the personnel below the maximum permissible exposure. Taking into account the continuous personnel radiation monitoring and medical supervision, radiation hazards in the operating room can be considered low.
Hyperphosphorylated and aggregated human protein tau constitutes a hallmark of a multitude of neurodegenerative diseases called tauopathies, exemplified by Alzheimer's disease. In spite of an enormous amount of research performed on tau biology, several crucial questions concerning the mechanisms of tau toxicity remain unanswered. In this paper we will highlight some of the processes involved in tau biology and pathology, focusing on tau phosphorylation and the interplay with oxidative stress. In addition, we will introduce the development of a human tau-expressing yeast model, and discuss some crucial results obtained in this model, highlighting its potential in the elucidation of cellular processes leading to tau toxicity.
Hydantoin (imidazolidine-2,4-dione) is a 2,4-diketotetrahydroimidazole discovered by Baeyer in 1861. Thiohydantoins and derivatives were prepared, having chemical properties similar to the corresponding carbonyl compounds. Some biological activities (antimicrobial, anticonvulsant, schistosomicidal) are attributed to the chemical reactivity and consequent affinity of hydantoinic rings towards biomacromolecules. Therefore, knowledge about the chemistry of hydantoins has increased enormously. In this review, we present important aspects such as reactivity of hydantoins, acidity of hydantoins, spectroscopy and crystallographic properties, and biological activities of hydantoin and its derivatives. (author)
An extension of the Hodgkin-Huxley mathematical model for the propagation of nerve signal which takes into account dynamical heat transfer in biological tissue is derived and fine tuned with existing experimental data. The medium is heated by Joule's effect associated with action potential propagation, leading to characteristic thermal patterns in association with spiral and scroll waves. The introduction of heat transfer-necessary on physical grounds-provides a novel way to directly observe the movement, regular or chaotic, of the tip of spiral waves in numerical simulations and possibly in experiments regarding different biological excitable media.
A confocal microscopy imaging system was devised to selectively detect Second harmonic signals generated by biological tissues. Several types of biological tissues were examined using this imaging system, including human teeth, bovine blood vessels, and chicken skin. All these tissues generated strong second harmonic signals. There is considerable evidence that the source of these signals in tissue is collagen. Collagen, the predominant component of most tissues, is known to have second order nonlinear susceptibility. This technique may have diagnostic usefulness in pathophysiological conditions characterized by changes in collagen structure including malignant transformation of nevi, progression of diabetic complications, and abnormalities in wound healing.
The first candidate rotavirus vaccine was a live attenuated oral vaccine made by the classical empirical method of serial passage of virus in tissue culture cells. Current tetravalent vaccine candidates that are in the final stages of efficacy testing in the United States were made by genetic reassortment. This article briefly highlights how advances in the basic understanding of the molecular biology of rotaviruses have facilitated vaccine development. New approaches for second-generation vaccines and improvements in vaccine efficacy based on further exploitation of the tools and knowledge of rotavirus molecular biology and pathogenesis are discussed. PMID:8752289
The High Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory is one of the world's most powerful research reactors. In 1996, one year after the demise of the Advanced Neutron Source Project, the U.S. Department of Energy embarked on an aggressive program to upgrade the neutron scattering facilities at the HFIR. These upgrades, which are now in progress, include the installation of larger beam tubes, a high-performance hydrogen cold source, and additional neutron guides and neutron scattering instruments. An extensive analysis effort was performed over the past 4 yr to support the design of the modified beamlines and new user facilities and to assess the impact of the upgrades on the integrity of the existing reactor system. The results of three of these analyses are summarized here. Specifically, results are presented for analyses related to the design of the new cold neutron source (CNS), the assessment of beam tube changes on the anticipated pressure vessel lifetime, ...
Why we sleep remains one of the enduring unanswered questions in biology. At its core, sleep can be defined behaviorally as a homeostatically regulated state of reduced movement and sensory...Full Text Available
Advances in molecular technologies challenge the different concepts of causality in biology, epidemiology and multistage mathematical models. The lack of integration of the different aspects of causality...Full Text Available
-Evaluacion de la fotosintesis y respiracion de especies de macroliquenes significativas en la tundra antartica. -Estudio de las isoenzimas en liquenes ...
The molecular structure, chemical properties, and biological function of the xyloglucan polysaccharide isolated from cell walls of suspension-cultured sycamore (Acer pseudoplatanus)...Full Text Available
... Astronomy & Space Biology Chemistry & Materials Computing Earth & Environment Education ... Materials Research Center at the University of Chicago, one of nearly 30 NSF-supported Materials ...
The WHO Expert Committee on Biological Standardization authorized the National Institute for Medical Research to establish an International Reference Preparation of Erythropoietin on the basis of the...Full Text Available
As the amount of biological data grows, so does the need for biologists to store and access this information in central repositories in a free and unambiguous manner. The European Bioinformatics Institute...Full Text Available
Some biological effects of hypoglycin-A, a compound isolated from the fruit of Blighia sapida, have been investigated. Administration of this compound to animals caused drowsiness...Full Text Available
During their catalytic cycle, proteins involved in biological signal transduction undergo unexpectedly large conformational changes, which are at the core of their biological functioning. Until now it has been extremely difficult to obtain experimental insight into the nature of these conformational changes. Mathematical modeling and time-resolved X-ray crystallography have resulted in probable routes along which these conformational changes may take place, but so far this fundamental biological phenomenon has hardly been tackled experimentally. Here, we report on an attempt to observe structural changes in Photoactive Yellow Protein with time-resolved small-angle neutron scattering using diffractometer D22 at the high-flux reactor of the Institut Laue-Langevin, Grenoble, France.
During their catalytic cycle, proteins involved in biological signal transduction undergo unexpectedly large conformational changes, which are at the core of their biological functioning. Until now it has been extremely difficult to obtain experimental insight into the nature of these conformational changes. Mathematical modeling and time-resolved X-ray crystallography have resulted in probable routes along which these conformational changes may take place, but so far this fundamental biological phenomenon has hardly been tackled experimentally. Here, we report on an attempt to observe structural changes in Photoactive Yellow Protein with time-resolved small-angle neutron scattering using diffractometer D22 at the high-flux reactor of the Institut Laue-Langevin, Grenoble, France
... kinematic model for the robots and designed ... theoretic approach for modeling mobile robot teamn formations". ... "UUV teams, control from a biological ...
There is an urgent need in aquaculture to develop microbial control strategies, since disease outbreaks are recognized as important constraints to aquaculture production and trade and since the development...Full Text Available
Orphan G protein-coupled receptors (GPCRs) are receptors lacking endogenous ligands. Found by molecular biological analyses, they became the roots of reverse pharmacology, in which receptors are attempted...Full Text Available
Histamine and the histamine receptors are important regulators of a plethora of biological processes, including immediate hypersensitivity reactions and acid secretion in the stomach. In these...Full Text Available
Cellular actions of thyroid hormone may be initiated within the cell nucleus, at the plasma membrane, in cytoplasm, and at the mitochondrion. Thyroid hormone nuclear receptors (TRs) mediate the biological...Full Text Available
SummaryThe polarized nature of neurons as well as the size and density of synapses complicates the manipulation and visualization of cell biological processes that control synaptic...Full Text Available
Motivation: Inference of haplotypes from genotype data is crucial and challenging for many vitally important studies. The first, and most critical step, is the ascertainment of a biologically...Full Text Available
Hie synthesis of diverse biologically important compounds, under condi- tions which existed on the earth in the initial period of its evolution, ha; ...
Congruence is a broadly applied notion in evolutionary biology used to justify multigene phylogeny or phylogenomics, as well as in studies of coevolution, lateral gene transfer, and as evidence for...Full Text Available
The biological half-life of "1"3"7Cs in the total body of human subjects was determined in 23 individuals of Japanese male adult in their normal works by measuring amount of "1"3"7Cs in both their total body and daily urine in the same period. For the group, the value was determined by averaging the half-lives for individuals, by comparing the mean body burden and the mean daily urinary excretion, or by applying a curve fitting method to the body burden estimate. The biological half-life averaged 86 days, ranging from 50 to 161 days. The averages of the biological half-lives for the group were 83, 87 and 82 days in the different periods of observation. By the curve fitting method, 85 days was found for the group. The biological half-life for the individuals depended on both body weight and age, to a lesser extent, of the subjects. (author).
High-throughput genomic and proteomic technologies have generated a wealth of publicly available data on ageing. Easy access to these data, and their computational analysis, is of great importance in...Full Text Available
A tunable diode laser is used to obtain infrared spectra of carbon dioxide in biological materials. The spectral resolution is sufficient to readily distinguish differing isotopic species. The technique may prove useful in clinical tests.
CAAX proteins are widely involved in global cellular functions such as proliferation, differentiation, and carcinogenesis. As an important modulator of biological activity, signal transduction via protein...Full Text Available
Breast cancer in the elderly has attracted considerable interest in recent years for three main reasons. Firstly, information concerning the profile (clinical and biological) of the disease in the geriatric...Full Text Available
... view on the utility of such attacks, see JH Rothschild, Tomorrow's Weapons ... Aum Shinrikyo may have had a stolen vaccine anthrax strain incapable ...
-Estudio sobre la fijacion de nitrogeno, fotosintesis y reconolizacion ... - Fotosintesis y relaciones hidricas en liquenes nanofruticulosos antarticos. ...
Pseudomonas stutzeri is a nonfluorescent denitrifying bacterium widely distributed in the environment, and it has also been isolated as an opportunistic pathogen from humans. Over the...Full Text Available
... abundance though an effect on escapement. The lobster aquaculture model continues to be updated as new biological ... become available. A monograph on the economics of aquaculture is near completion....
We investigate the profound relation between the equations of biological evolution and quantum mechanics by writing a biologically inspired equation for the stochastic dynamics of an ensemble of particles. Interesting behavior is observed which is related to a new type of stochastic quantization. We find that the probability distribution of the ensemble of particles can be decomposed into eigenfunctions associated to a discrete spectrum of eigenvalues. In absence of interactions between the particles, the out-of-equilibrium dynamics asymptotically relaxes towards the fundamental state. This phenomenon can be related with the Fisher theorem in biology. On the contrary, in presence of scattering processes the evolution reaches a steady state in which the distribution of the ensemble of particles is characterized by a Bose-Einstein statistics. In order to show a concrete example of this stochastic quantization we have solved ...
BackgroundMany difficult problems in evolutionary genomics are related to mutations that have weak effects on fitness, as the consequences of mutations with large effects are often...Full Text Available
The current state and need for radiation protection training in Finland have been surveyed by the Radiation and Nuclear Safety Authority STUK. The survey sought to determine whether the current requirements for radiation protection training had been met, and to promote radiation protection training. Details of the scope and quality of present radiation protection training were requested from all educational institutes and organizations providing radiation protection training. The survey covered both basic and further training, special training of radiation safety officers, and supplementary training. The questionnaire was sent to 77 educational organization units, 66 per cent of which responded. Radiation workers and radiation safety officers were asked about radiation protection ...
The assumed linear relationship between exposure to radiation and cancer incidence is questioned in this article. The current research data on radiation effects at the cellular level is reviewed, as are epidemiological studies of background radiation effects and health effects of populations exposed to low levels of radiation exposure via employment or medical treatments. Statistics reveal that threshold levels currently in force need to be reviewed. Some evidence of beneficial effects of low level radiation exposure effects of low level radiation exposure is also presented, and so regulations should be reviewed at an international level. (UK).
The most propagated mechanisms of stimulated radiation of electron beam such as Cherenkov one-particle and collective effects, ondulator and magnetic bremsshrahlung radiations, Doppler anomalous effect, Thompson and Raman scattering and radiation are discussed. Relation of spontaneous radiation mechanisms of individual electron and stimulated radiation effects in electron beams has been elucidated, grounds of linear electrodynamics of radiative beam instabilities are stated, and main mechanisms of their nonlinear stabilization are elucidated as well. Various simulated processes in electron beams are considered from the unique point of view using a simple mathematical apparatus and such physical laws as conservation and Newton laws.
Purpose: Various published reports involving intensity-modulated radiotherapy (IMRT) plans developed using automated optimization (inverse planning) have demonstrated highly conformal plans. These reported conformal IMRT plans involve significant target dose inhomogeneity, including both overdosage and underdosage within the target volume. In this study, we demonstrate the development of optimized beamlet IMRT plans that satisfy rigorous dose homogeneity requirements for all target volumes (e.g., #+-#5%), while also sparing the parotids and other normal structures. Methods and Materials: The treatment plans of 15 patients with oropharyngeal cancer who were previously treated with forward-planned multisegmental IMRT were planned again using an automated optimization system developed in-house. The optimization system allows for variable sized beamlets computed using a three-dimensional convolution/superposition dose calculation and flexible cost functions derived from combinations of ...
Here we examine Fe speciation within Fe-encrusted biofilms formed during 2-month seafloor incubations of sulfide mineral assemblages at the Main Endeavor Segment of the Juan de Fuca Ridge. The biofilms were distributed heterogeneously across the surface of the incubated sulfide and composed primarily of particles with a twisted stalk morphology resembling those produced by some aerobic Fe-oxidizing microorganisms. Our objectives were to determine the form of biofilm-associated Fe, and identify the sulfide minerals associated with microbial growth. We used micro-focused synchrotron-radiation X-ray fluorescence mapping (mu XRF), X-ray absorption spectroscopy (mu EXAFS), and X-ray diffraction (mu XRD) in conjunction with focused ion beam (FIB) sectioning, and highresolution transmission electron microscopy (HRTEM). The chemical and mineralogical composition of an Fe-encrusted biofilm was queried at different spatial scales, and the spatial relationship between primary ...
The work is devoted to a microscopic analysis of the reactive capacity of chitin. An algorithm for modeling the deacetylation reaction in a monomeric unit of chitin is described. The reaction coordinate and the potential energy surface topography are determined taking into account the electron-vibrational interaction and low-symmetry perturbations within Jahn-Teller theory. Based on this algorithm, the topological modeling of the deacetylation process is performed for the first time and a mechanism of the biological activity of chitosan is proposed.
The application of kinetic probes that allow one to determine relative reactivities of biologically relevant substrates with oxidizing intermediates in the Fenton reagent (H2O2 plus Fe2+ in acidic aqueous...Full Text Available
The physical foundations and methodology are described of radionuclide X-ray fluorescence analysis. The sources are listed of air, water and soil pollution, and the transfer of impurities into biological materials is described. A detailed description is presented of the sampling of air, soil and biological materials and their preparation for analysis. Greatest attention is devoted to radionuclide X-ray fluorescence analysis of the components of the environment. (ES).
New standardization techniques of samples in multielement instrumental neutron-activation analysis (INAA) of biological materials (BM) are considered. New methodical developments of sample preparation techniques, BM tableting, creation of comparison standards and standardization of packing material are suggested. Correlated data on concentration of different elements in standard specimens-comparison standards are presented for mass INAA, that is: for phenol-formaldehyde resin-base and human blood-base synthetic standards. 7 refs.; 3 tabs.
Data on a technology for the manufacture of a new biologically active humic preparation based on the Neogene brown coals deposited in Belarus are presented. The physicochemical properties of the preparation are given, and its biological activity is evaluated; the results of plant cultivation tests in the basic crops of the region?potatoes and grain crops?are also considered.
This report is a brief review of biological and medical applications of ion-track membranes. The review aims at informing nuclear physicists about alternative (i.e. non-fundamental-science) use of heavy ion accelerators such as production of micro- and nano-porous materials. The ion-track membranes produced this way are employed in life sciences and numerous technological applications. The author focuses on recent results from the Flerov laboratory in co-operation with other scientific institutions and industrial partners.
Constructive and combinatorial relationships between order-isomorphisms and order-equivalence classes within the generalized genetic code are presented, not only for the biologically relevant groups of order 4, but also for finite groups of arbitrary order. The main result is the derivation of the number (and types) or order-equivalence classes for a group of order n. Finally, an extension of this work to all biologically admissible alternative codes is discussed.
A procedure for the determination of lead in various biological and environmental samples by "2"0"3Pb radioisotope dilution substoichiometric method is presented. The accuracy of the method by comparison with the literature values of reference materials appears to be good. The standard deviation of the method is less than 10%, and detection limit is about 0.1 #mu#g of lead. (author) 5 refs.
This book presents the current knowledge about the effects of electromagnetic fields on living matter. The three-part format covers dielectric permittivity and electrical conductivity of biological materials; effects of direct current and low frequency fields; and effects of radio frequency (including microwave) fields. The parts are designed to be consulted independently or in sequence, depending upon the needs of the reader. Useful appendixes on measurement units and safety standards are also included.
Current investigations into the biological solubilization of coal with microorganisms focus on the production of solubilizing activity in fungi. Test organisms for this work include a species of the yeast Candida previously isolated from a lignite outcrop, and P. chrysosporium, a filamentous higher fungus which has played a major role in lignin biodegradation research. The studies described are primarily exploratory in nature, and are fundamental to the design of more sophisticated inquiries into the physiology of fungal coal solubilization.
Efforts during the past year by the US Department of Energy and the Electric Power Research Institute-funded laboratories to investigate the biological effects from electric fields are described in resume form. Investigations generally have been summarized with objectives, accomplishments of the past year, and some indication of projected studies.
The LLNL Chemical & Biological National Security Program (CBNP) provides science, technology and integrated systems for chemical and biological security. Our approach is to develop and field advanced strategies that dramatically improve the nation's capabilities to prevent, prepare for, detect, and respond to terrorist use of chemical or biological weapons. Recent events show the importance of civilian defense against terrorism. The 1995 nerve gas attack in Tokyo's subway served to catalyze and focus the early LLNL program on civilian counter terrorism. In the same year, LLNL began CBNP using Laboratory-Directed R&D investments and a focus on biodetection. The Nunn-Lugar-Domenici Defense Against Weapons of Mass Destruction Act, passed in 1996, initiated a number of U.S. nonproliferation and counter-terrorism programs including the DOE (now NNSA) Chemical and Biological ...
A survey is presented of studies dealing with radionuclide X-ray fluorescence analysis (RXFA) of impurities in the air, water, soil, sediments and biological materials, mainly blood, urine, hair, soft tissues and bones. Tabulated are lists of published works on RXFA of the air, water and biological materials. (ES).
The Gordon Research Conference (GRC) on 2004 Gordon Research Conference on Reversible Associations in Structure & Molecular Biology was held at Four Points Sheraton, CA, 1/25-30/2004. The Conference was well attended with 82 participants (attendees list attached). The attendees represented the spectrum of endeavor in this field coming from academia, industry, and government laboratories, both U.S. and foreign scientists, senior researchers, young investigators, and students.
Pentaerythritol tetranitrate (PETN) is a relatively sensitive explosive used in many electroexplosive devices as well as in medicine. Of primary interest to LLNL is its use in items such as exploding bridgewire (EBW) detonators and exploding bridge foil initiators (EFI). In these devices the crystalline powder is pressed into a granular, low-density compact that can be initiated by an exploding wire or foil. The long-term stability of this pressed compact is of interest to weapon stockpile lifetime prediction studies. Key points about potential aging mechanisms can be summarized as follows: (1) There are a number of factors that can contribute to PETN instability. These include particle size, polymorphic phase transitions, crystal structure, impurities, moisture, occlusions, chemical incompatibility and biological (microorganism) action. of these factors the most important for long-term aging of high surface area powders used in detonators appears to be that of ...
The use of the ratio of the characteristic intensity to the continuum background intensity (P/B ratio) of the X-ray spectrum for a quantitative ion microprobe (IMP) or PIXE (particle induced X-ray emission) analysis of thin biological specimens was proposed previously. The IMP analysis of thick biological specimens is also of considerable practical use. In this paper, the possibility of using the P/B ratio to quantify minor elements in thick biological specimens is investigated. The epoxy resin based standards with gradual concentrations of KCNS up to 0.6 mol/kg and NBS bovine liver were analyzed by a 27 MeV {alpha} particle microprobe. The measured peak to background ratios (between 4.4 to 5.7 keV) agreed well with the theoretical calculations. The calculations showed that the concentration dependence of the P/B ratios was determined mainly by the absorption of X-rays in specimens. The results indicate that the P/B method ...
This study was designed to compare the levels of chromium (Cr) and manganese (Mn) in scalp hair, blood, and urine of night blindness in children age ranged (3-7) and (8-12) years of both genders, comparing them to sex- and age-matched controls. A microwave-assisted wet acid digestion procedure, was developed as a sample pretreatment, for the determination of Cr and Mn in biological samples of night blindness children. The proposed method was validated by using conventional wet digestion and certified reference samples of hair, blood and urine. The digests of all biological samples were analyzed for Cr and Mn by electrothermal atomic absorption spectrometry. The results indicated significantly higher levels of Cr, whilst low level of Mn in the biological samples (blood and scalp hair) of male and female night blindness children, compared with control subjects of both genders. These data present guidance to clinicians and ...
WASAG DECON developed a concept for the biological in situ remediation of an TNT-contaminated former seepage pond. This pond is located on the site of an ammunition factory in Lower Saxony. Unit 1982 all the waste water from the production buildings was directed into this pond, including TNT-contaminated water from the flushing of shells. Due to this practice, the sediment of the pond, the underlying soil and the groundwater became contaminated with TNT. The area of the soil contamination adds to abut 2.000 m{sup 2}. The remediation concept includes three steps: 1. Excavation of the most highly contaminated soil with TNT-concentrations above 1000 mg/kg. 2. Reduction of the remaining contamination by a biological in situ treatment using organic and inorganic amendments and mechanical tillage. After about to years of treatment, remediation goals of 50 mg/kg are expected to be reached on most of the area. 3. Contaminations eventually remaining in ...
Heat production in biological materials due to absorption of radiowaves and microwaves can be used in applications as diverse as cancer treatment and cooking. However, the hazards of overexposure range from hyperthermia to cataracts and internal burns. To maximize the clinical benefits and minimize potential hazards, the biological effects of radiowaves and microwaves must be understood. Dielectric measurements can be used to determine the extent of such effects in various applications and at various levels of exposure. The values of maximum permissible exposure levels that are likely to be recommended aeat production in biological materials due to absorption of radiowaves and microwaves can be used in applications as diverse as cancer treatment and cooking. However, the hazards of overexposure range from hyperthermia to cataracts and internal burns. To maximize the clinical benefits and minimize potential hazards, the ...
This manual was written for individuals who wish to become qualified in radiation protection as an adjunct to working with sources of ionizing radiation or using radionuclides in the field of medicine. It provides the radiation user with information needed to protect himself and others and to understand and comply with governmental and institutional regulations regarding the use of radionuclides and radiation machines. It is designed for a wide spectrum of users, including physicians, research scientists, engineers, and technicians. It should be useful also to radiation safety officers, members of radiation safety committees, and others who are responsible for the proper use of radiation sources, although they may not be working with the sources directly. The presentation in this manual is designed to obviate the need for reviews of atomic ...
Abstract Satellite measurements and numerical forecast model reanalysis data are used to compute an updated estimate of the cloud radiative effect on the global multi-annual mean radiative energy budget of the atmosphere and surface. The cloud radiative cooling effect through reflection of short wave radiation dominates over the long wave heating effect, resulting in a net cooling of the climate system of - 21 Wm-2. The short wave radiative effect of cloud is primarily manifest as a reduction in the solar radiation absorbed at the surface of - 53 Wm-2. Clouds impact long wave radiation by heating the moist tropical atmosphere (up to around 40 Wm-2 for global annual means) while enhancing the radiative cooling of the atmosphere over other regions, in particular higher latitudes and sub-trop...
The experimental device for generation of undulator radiation in terahertz wavelength region by use of undulator with ferromagnets is created. The device is based on a beam of a microtron with the energy 7.5 MeV. The radiation wavelength is 200 mu. Registered spontaneous radiation has a power 10{sup -6} W at a current of a beam 2 mA in a pulse. With the optical resonator, in a mode, the amplification of 6% is received, that in sometimes is more than the expected value. This effect is explained as a result of partial coherence of radiation.
The emission of Cerenkov radiation by tachyons has been examined by using the reduced expansions of superluminal electromagnetic fields in terms of standard helicity representation of Poincare group. It has been shown that the tachyons emit Cerenkov radiation through their coupling only with subluminal electromagnetic fields and that a charged tachyon can emit Cerenkov radiation only in the media in which it travels with a velocity lower than that of light while in the usual medium in which its velocity is more than that of light, it will never emit Cerenkov radiation.
The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.
High energy muon colliders, such as the TeV-scale conceptual designs now being considered, are found to produce enough high energy neutrinos to constitute a potentially serious off-site radiation hazard in the neighbourhood of the accelerator site. A general characterization of this radiation hazard is given, followed by an order-of-magnitude calculation for the off-site annual radiation dose and a discussion of accelerator design and site selection strategies to minimize the radiation hazard.
Correlation characteristics of quantum noise on the shadow radiation image (RI) of the object under nondestructive testing are studied. Mathematical model of RI occasional distortions is derived. The model takes into account the parameters of object under testing and of radiation beam by radiation quanta flux density. The results obtained can be used as a component in the process of investigation of various radiation testing systems
Coherent oscillator radiation is considered. A comparison is made with classical particle radiation with gauss distribution. Decay probability for coherent state in spontaneous radiation is estimated. The method suggested for describing harmonic oscillator allows to separate the effect of classical field radiation from quantum description of particle state within the framework of a self-consistent quantum mechanical problem.
A new type of radiation which occurs when particles are accelerated in the field of a longitudinal wave and in a transverse magnetic field is studied. The characteristics of such spontaneous radiation are obtained, and the influence of collective effects on the radiation is analyzed. The application of the findings to the theory of free electron lasers is discussed. 8 references.
Objectives To provide direct estimates of risk of cancer after protracted low doses of ionising radiation and to strengthen the scientific basis of radiation protection standards for environmental,...Full Text Available
Forty-four patients with histologically proven Hodgkin's disease underwent initial treatment with extended-field radiation therapy. Nineteen of these patients also received combination chemotherapy....Full Text Available
Exact anatomic knowledge about the location of the gonads and the application of corresponding measures of radiation protection are the preconditions for an efficient reduction of the danger of a possible genetic damage as a result of radiation exposition during X-ray examination of the hip joint of newborns. (VJ).
Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available
Analytical method of theoretical simulation of collective hydrodynamic instabilities of intensive flows of discrete radiators, interacting with each other only through the coherent fields of their spontaneous radiation in corresponding media was suggested...
... Top of page Testing Radiation coming from granite countertops results from natural radioactive material in the granite. Identifying the presence and concentration of radioactive elements in granite requires expensive and sophisticated portable instruments or laboratory equipment. These instruments and equipment require proper calibration, and interpretation of ...
The different radiation loads caused by natural and artificial radionuclides are compared in this paper. This examples will serve to illustrate that the problem of population exposure to radiation can only be solved in consideration of all components and to show which effects of the radiation from natural sources are of special importance in this connexion. (orig./AK).
The problem of optimizing a horn radiator of electromagnetic waves for the reflection coefficient and the coefficient of transformation of the fundamental mode into higher order modes is solved. Optimization is performed by means of selecting a combined shape of the radiator generatrices.
A meeting was held on October 15, 16, 17, 1990 to discuss the state of tritium safety and environmental effects. The meeting was organized with the help of the International Energy Agency planning committee consisting of K. Steinmetz, Y. Seki, G. Nardella, and G. Vivian. Representative of tritium production facilities and heavy water reactor power production were also involved. The meeting was organized to address seven topics in tritium safety that were thought to require further work. The topics were: (1) materials science, (2) environmental models, (3) environmental model validation, (4) tritiated organic compounds, (5) human dosimetry, (6) tritium sampling and measurement, and (7) long-term environmental databases.
Cellular telephones emit a radiofrequency electromagnetic field, part of which is absorbed in the user's head. Many studies have been conducted to look for their possible health hazard to human, at the experimental, epidemiological or clinical level. After a short recall on dosimetry, the author describes the state-of-the art about harmful and irreversible effects, up to now not confirmed, and about some benign symptoms which look absolutely actual. A causal relationship of the electromagnetic field on these benign symptoms is however not proven; other, studies are running to evaluate their possible long-term consequences. Interferences with cardiac pacemakers can easily be avoided by holding the telephone handset farther than 10 cm. (author)
The basic relationships of the convolution/superposition dose calculation technique are reviewed, and a modelling technique that can be used for obtaining a satisfactory beam model for a commercially available convolution/superposition-based treatment planning system is described. A fluence energy spectrum for a Co-60 treatment machine obtained from a Monte Carlo simulation was used for modelling the fluence spectrum for a Rokus M machine. In order to achieve this model we measured the depth dose distribution and the dose profiles with a Wellhofer dosimetry system. The primary fluence was iteratively modelled by comparing the computed depth dose curves and beam profiles with the depth dose curves and crossbeam profiles measured in a water phantom. The objective of beam modelling is to build a model of the primary fluence that the patient is exposed to, which can then be used for the calculation of the dose deposited in the patient. (authors)
The MCNPE-BO and MCNP4 Monte Carlo electron-photon codes were used to calculate the dose equivalent per unit fluence at various depths in tissue-equivalent slab phantoms for broad parallel beams of monoenergetic electrons with energies from 50 keV to 10 MeV. The study was carried out in the framework of the activities of a ICRP/ICRU Joint Task Group with the support of EURADOS WG4 (Numerical Dosimetry). Some preliminary results and comparisons as well as a general discussion on the performances of the codes are presented, demonstrating quite a satisfactory agreement among the results obtained using the two codes and those of other authors. (author).
Subcutaneous involvement frequently occurs in maxillary sinus carcinoma. Radical resection does not include removal of the skin at risk. In standard postoperative wedge-pair treatment plans, the surface dose is dependent upon beam weighting, beam energy, and patient contour. Thermoluminescent dosimetry (TLD) measurements were performed to evaluate the surface dose of patients undergoing postoperative irradiation of maxillary sinus carcinoma following primary resection. When 60 Gy was delivered to isocenter with a 45 degrees wedge pair and 6 MV photons with 1 cm bolus, the subcutaneous tissues at risk received {approximately} 30 Gy. Based upon presented TLD measurements, supplemental electron beam therapy to the subcutaneous tissues if primarily involved should be considered.
The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source volumes and the re iden e times in total body and the target organs. Examples are given for the calculation of somatically effective dose equivalent for ...
The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source volumes and the re iden e times in total body and the target organs. Examples are given for the calculation of somatically effective dose equivalent for ...
In everyday radiotherapy we must carry out the determination of absorbed dose measurement according to JARP's protocol. We explained an outline of JARP's 1974 and 1986 protocol in electron beam therapy, and mentioned it about the matter that should examined. To use it easily in clinic, a simplified procedure based on precisely to JARP's 1986 protocol is practical, the character of this procedure settles briefly the determination of mean incident energy of electron beams and get ready to table of ionization to absorbed dose conversion factor for various ionization chamber. Also, this procedure almost not influence on the accuracy of determination. We described systematically practical procedure for requisite absorbed dose calculation in a patient in electron beam therapy. (author).
Objective: To establish a computer program for rapid calculation of internal committed effective close through inhalation and ingestion pathways under radiological emergency. Methods: Visual Basic 6.0 is used to compile the generic procedures of internal committed effective dose by inhalation and ingestion in IAEA-TECDOC-1162, Generic Procedures for Assessment and Response during a Radiological Emergency. Results: The assessment methodology of internal committed effective dose by inhalation and ingestion under radiological emergency in the report IAEA-TECDOC-1162 can be coded into a computer program. Conclusions: This research provides a rapid method of assessment for internal committed effective dose by inhalation and ingestion under radiological emergency, and it may provide needed dosimetry data for treatment under emergency response. (authors)
An optical klystron is built in the 800 MeV electron storage ring at University of Science and Technology of China for harmonic super-radiation generation. In single bunch operation mode the repetition rate of the spontaneous radiation pulses is about 4.533 MHz, and the repetition rate of the seed laser pulses is about 3 Hz, while the radiation pulse duration is 300 ps. For measuring harmonic radiation a high on/off ratio ICCD is used as an optical switch to reject spontaneous radiation pulses of high repetition rate
The document published under A/63:46 and titled report of the scientific committee of United Nations for the study of ionizing radiations effects, gives the situation of the fifty sixth session of the committee that stood at Vienna from the 10. to 18. july 2008. In the chapter 3 of this report the writers summarize the strategic planning and the working program of the scientific committee for the period 2009-2013. They note that the committee worry about the inadequate means, particularly in personnel. The priorities for the given period will be the medical exposure of patients, the radiation levels and the effects of energy production, the exposure to natural radiation sources and the improvement of the understanding of the effects of the low doses radiation exposure. (N.C.)
Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available
By proposing the four-dimensional, reciprocity transformations the appropriate condition for superluminal electromagnetic Cerenkov radiation is obtained by introducing the hypothesis that tachyons possess vector energy and scalar momentum.
drical Enclosures Using a Numerical Ray Tracing Technique. NASA. TM-I02527, 1990 . Buckley, H.: Radiation from the Interior of a Reflecting Cylinder. Philos. ...
... iFfficiency-en- enhanced spontaneous radiation at the free-electron- ... as enhanced spontaneous radiation at the free-electron-laser wavelength. ...
The introduction of tolerance to radiation (''radiation-hardness'') into large electronic systems is one of the major tasks to which this Handbook will be put. The practices recommended here for inculcating radiation-tolerance in equipment require advanced physical modeling techniques, precise engineering procedures, and firm assurance procedures. The degree to which these procedures should be used in an equipment project can be measured by the severity of the raw radiation environment, the desired reliability of the system, and the requirement of that project for radiation-sensitive technologies. The balance of device/circuit design versus shielding will depend on whether the radiation is highly penetrating -- as in isotope handling or military environments -- or readily attenuated, as in space. In this chapter the authors have attempted to summarize the ...
When energetic bunches of electrons traverse an undulator field, they can spontaneously emit radiation both coherently and incoherently. Although it has generally been assumed that undulator radiation is incoherent at wavelengths short compared to the longitudinal size of the electron bunch, several recent observations have proved this assumption false. Furthermore, the appearance of coherent radiation is often accompanied by a significant increase in radiated power. Here we report observations of strongly enhanced coherent spontaneous radiation together with direct measurements, using transition radiation techniques, of the electron distributions responsible for the coherent emission. We also report demonstrated enhancements in the predicted spontaneous radiated power by as much as 6x10"4 using electron bunch compression. copyright 1996 ...
... spontaneous radiation of amplifiers within a relatively w~de range of ... pulse widths are 20-30ns, while amplified spontaneous radiation pulse ...