WorldWideScience
1

Space Radiation Detector with Spherical Geometry  

Science.gov (United States)

A particle detector is provided, the particle detector including a spherical Cherenkov detector, and

2011-01-01

2

View Record - NASA Jet Propulsion Laboratory  

Science.gov (United States)

Jan 13, 2011 ... This 360-degree mosaic of images from the navigation camera on ... The Radiation Assessment Detector, shown prior to its September 2010 ...

3

Space Images - NASA Jet Propulsion Laboratory  

Science.gov (United States)

Jan 18, 2011 ... The Radiation Assessment Detector, shown prior to its September 2010 ... This 360-degree panorama shows the vista from the location where ...

5

Nondestructive testing of metal coating thickness and control of chemical composition using radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The principle is described of a method using low-activity emitters as the primary radiation source for analysis. The selection of the radiation source and the detection methods including the assessment of the applicability of various radiation detectors are discussed. The benefits and the constraints of the method are considered. Practical examples are presented showing the application possibilities of the method for testing the thickness of bearing layers, piston ring coats, lead layers, etc. The possibility is shown of applying the rapid test for the composition of tungsten and chromium alloyed metal materials in testing complex systems. (J.K.).

1974-12-03

6

Semiconductor Radiation Detectors with Frisch Collars and Collimators for Gamma Ray Spectroscopy and Imaging  

Energy Technology Data Exchange (ETDEWEB)

To study CdZnTe as a high energy resolution gamma ray detector with a novel new design, and to build a detector array from the new detector design

2006-12-04

8

ASE FILE  

Science.gov (United States)

radionuclide X-ray fluorescence analysis: the resolving power of the ... The radiation detectors used in radionuclide X-ray fluorescence ...

9

Method and system for determining depth distribution of radiation-emitting material located in a source medium and radiation detector system for use therein  

Energy Technology Data Exchange (ETDEWEB)

A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the ...

2003-03-04

10

Resonant-mass detectors of gravitational radiation  

International Nuclear Information System (INIS)

A network of second-generation low-temperature gravitational radiation detectors is nearing completion. These detectors, sensitive to mechanical strains of order 10"-"1"8, are possible because of a variety of technical innovations that have been made in cryogenics, low-noise superconducting instrumentation, and vibration isolation techniques. Another five orders of magnitude improvement in energy sensitivity of resonant-mass detectors is possible before the linear amplifier quantum limit is encountered. 33 references, 3 figures, 1 table.

1987-07-01

11

From tomography to voludensitometry: radiation detectors for industrial control and medical instrumentation; De la tomographie a la voludensitometrie: les capteurs pour le controle industriel et l`instrumentation medicale  

Energy Technology Data Exchange (ETDEWEB)

In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).

1993-12-01

12

Modeling of Fission Neutrons as a Signature for Detection of Highly Enriched Uranium  

Energy Technology Data Exchange (ETDEWEB)

We present the results of modeling intended to evaluate the feasibility of using neutrons from induced fission in highly enriched uranium (HEU) as a means of detecting clandestine HEU, even when it is embedded in absorbing surroundings, such as commercial cargo. We characterized radiation from induced fission in HEU, which consisted of delayed neutrons at all energies and prompt neutrons at energies above a threshold. We found that for the candidate detector and for the conditions we considered, a distinctive HEU signature should be detectable, given sufficient detector size, and should be robust over a range of cargo content. In the modeled scenario, an intense neutron source was used to induce fissions in a spherical shell of HEU. To absorb, scatter, and moderate the neutrons, we place one layer of simulated cargo between the source and target and an identical layer between the target and detector. ...

2004-03-09

13

Gamma Radiation Detectors of the TA-55 Waste Line Monitoring System  

Energy Technology Data Exchange (ETDEWEB)

This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.

1999-06-01

14

Self-filling and self-purging apparatus for detecting spontaneous radiation from substances in fluids  

Energy Technology Data Exchange (ETDEWEB)

Disclosed herein is a radiation detector providing for the in situ automatic sampling of fluids containing substances emitting radiation, especially Cerenkov radiation. The detector permits sampling within well casings and is self-purging such that no additional provisions must be established for the storage and disposal of contaminated fluids.

1993-01-01

15

Multi-spectral schottky barrier infrared radiation detection array  

Energy Technology Data Exchange (ETDEWEB)

A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.

1983-12-27

16

Multi-spectral schottky barrier infrared radiation detection array  

International Nuclear Information System (INIS)

A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.

17

Development of a real-time, neutron and gamma dosimeter  

Energy Technology Data Exchange (ETDEWEB)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-07-01

18

Development of a real-time, neutron and gamma dosimeter  

International Nuclear Information System (INIS)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-06-10

19

Use of signal delay of one of detectors in two-channel radiometric flaw detector  

International Nuclear Information System (INIS)

A possibility is considered or reducing the surface heterogeneity effect of an item being tested on the result of radiation flaw detection by means of signal delay of one of detectors in a two-channel radiometric flaw detector. The exposure of a translationally moving item has been studied as well as an external exposure of a rotating hollow item.

20

Role of Mast Cells in Early and Delayed Radiation Injury in Rat Intestine  

Science.gov (United States)

... mast cell staining; ref. 16). The severity of structural radiation injury was assessed using a histopathological radiation injury score ... ...

21

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

22

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

23

Performance of the transition radiation detector in D{Phi}  

Energy Technology Data Exchange (ETDEWEB)

The transition radiation detector (TRD) for the D{Phi} experiment is currently in operation at Fermilab. Transition radiation production, which has been clearly observed in the collider data, makes the TRD a valuable tool to discriminate electrons and hadrons. We describe an algorithm based on the truncated energy, and illustrate its use for top signal and background. (authors). 7 refs., 6 figs., 2 tabs.

1994-12-31

24

Near-Core and In-Core Neutron Radiation Monitors for Real Time Neutron Flux Monitoring and Reactor Power Level Measurements  

Energy Technology Data Exchange (ETDEWEB)

MPFDs are a new class of detectors that utilize properties from existing radiation detector designs. A majority of these characteristics come from fission chamber designs. These include radiation hardness, gamma-ray background insensitivity, and large signal output.

2006-06-12

25

Influence of Dopants on Characteristics of X-Ray Detectors Fabricated from Indium-, Gallium-, and Chlorine-Doped Cadmium Telluride Single Crystals  

Science.gov (United States)

Counting characteristics of X-ray detectors fabricated from indium-doped, gallium-doped, and chlorine-doped CdTe have been investigated. The detectors fabricated from indium-doped and gallium-doped crystals showed radiation-induced polarization, namely, a progressive decrease of count rate with an increase of photon fluence in the high-photon-fluence region, while the detectors fabricated from chlorine-doped crystals did not. Results from current-voltage characteristics of the detectors indicated that the different counting characteristics of these detectors originated from the difference in internal electric fields in each detector.

1995-08-01

26

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the ...

2007-01-01

28

ITER Core Imaging X-Ray Spectrometer Conceptual Design and Performance Assessment - Phase 2  

International Nuclear Information System (INIS)

During Phase 2 of our study of the CIXS conceptual design we have tackled additional important issues that are unique to the ITER environment. These include the thermal control of the crystal and detector enclosures located in an environment with a 100-250 C ambient temperature, tritium containment, and the range of crystal and detector movement based on the need for spectral adjustments and the desire to make measurements of colder plasmas. In addressing these issues we have selected a ''Dewar''-type enclosure for the crystals and detectors. Applying realistic view factors for radiant heat and making allowance for conduction we have made engineering studies of this enclosure and showed that the cooling requirements can be solved and the temperature can be kept sufficiently constant without compromising the specification parameters of the CIXS. We have chosen a minimum 3 mm combined thickness of the six beryllium windows ...

29

Test of superconducting Nb/Al bilayers as particle detectors  

Energy Technology Data Exchange (ETDEWEB)

Superconducting thin film particle detectors can be very attractive due to the low sensitivity to radiation damage. We describe the fabrication procedure and the characterization of Nb/Al bilayers as particle detectors. First steady and dynamical results are reported from tests of 5 MeV alpha-particle detection.

2000-04-07

30

Neutronic detection device with extended flux range for control of nuclear reactors. Dispositif de detection neutronique a dynamique etendue pour le controle et la commande des reacteurs nucleaires  

Energy Technology Data Exchange (ETDEWEB)

The neutron detector is cased in a metal envelop and has one detector with a very sensitive fission chamber and a second detector with a fission chamber less sensitive that the first one and a boron coated ionisation chamber for reducing gamma radiation detection.

1992-06-12

31

Position sensitive detection of individual nuclear particle scintillations using image intensifier tubes  

International Nuclear Information System (INIS)

An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are ...

1996-01-01

32

A Versatile Evaporative Cooling System Designed for Use in an Elementary Particle Detector  

British Library Electronic Table of Contents (United Kingdom)

An evaporative cooling system developed for operation and qualification testing of silicon pixel and microstrip detectors for the inner tracking detector of the CERN ATLAS spectrometer is described. Silicon detector substrates must be continuously operated between 0 and ???7?C in the high radiation environment near the circulating beams at the CERN Large Hadron Collider (LHC). This requirement imposes unusual constraints on the cooling system and has led to the choice of perfluoro-n-propane (C3F8) refrigerant, which combines good chemical stability under ionizing radiation with high dielectric strength and nonflammability. Since the silicon detectors must also be of extremely light construction to minimize undesirable physics background, coolant tubes are of thin (200 ?m) aluminum wall, wh...

2007-01-01

33

DOE personnel neutron dosimetry evaluation and upgrade program  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. An Effective Dose ...

1988-10-01

34

Studies of crystalline CdZnTe radiation detectors and polycrystalline thin film CdTe for X-ray imaging applications  

CERN Document Server

The development of a replacement to the conventional film based X-ray imaging technique is required for many reasons. One possible route for this is the use of a large area film of a suitable semiconductor overlaid on an amorphous silicon readout array. A suitable semiconductor exists in cadmium telluride and its tertiary alloy cadmium zinc telluride. In this thesis the spectroscopic characteristics of commercially available CZT X- and gamma-radiation detectors are established. The electronic, optical, electro-optic, structural and compositional properties of these detectors are then investigated. The attained data is used to infer a greater understanding for the carrier transport in a CZT radiation detector following the interaction of a high energy photon. Following this a method used to fabricate large area films of CdTe on a commercial scale is described. This is cathodic ...

2001-01-01

35

Overview of the recent activities of the RD50 collaboration on radiation hardening of semiconductor detectors for the sLHC  

International Nuclear Information System (INIS)

The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1 MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.

2009-01-01

36

Overview of the recent activities of the RD50 collaboration on radiation hardening of semiconductor detectors for the sLHC  

British Library Electronic Table of Contents (United Kingdom)

The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.

2009-01-01

37

Guarantee outline of radiation hardening for satellite  

International Nuclear Information System (INIS)

The Guarantee Outline presents the technical demands of design and contents of assessment for radiation hardening in satellite engineering in China. It includes the basis of design in space environment of polar orbit, the contents of design for general radiation hardening, the requirements and assessments of the single-board computer, the requirements of design for circuits (including hardware and software), the choices and assessments for devices, and the primary stipulations for the requirements of design and assessments against the phenomenon of charge and discharge.

38

Quantum entanglement, recoherence and information flow in an accelerated detector - quantum field system: Implications for black hole information issue  

CERN Document Server

We study an exactly solvable model where an uniformly accelerated detector is linearly coupled to a massless scalar field initially in the Minkowski vacuum. Using the exact correlation functions we show that as soon as the coupling is switched on one can see information flowing from the detector to the field and propagating with the radiation into null infinity. By expressing the reduced density matrix of the detector in terms of the two-point functions, we calculate the purity function in the detector and study the evolution of quantum entanglement between the detector and the field. Only in the ultraweak coupling regime could some degree of recoherence in the detector appear at late times, but never in full restoration, as an earlier work seems to suggest. We explicitly show that under the most general conditions the ...

2007-01-01

39

Multichannel radiometric inspection systems with half-tone visualization of radiation shadow images. 1. Mathematical model  

International Nuclear Information System (INIS)

A mathematical model of multichannel radiometric inspection system was developed, in which the measurement results are reproduced in the form of a half-tone image equivalent to the radiation image of the irradiated object. The model makes the following assumptions: the beam of radiation is fan-shaped; the object of inspection is scanned discretely; the focal spot of the source is rectangular; the apertures of the detector are round, and the detectors themselves are equidistant from the sources, aimed at it, and form a close-packed array; the signals from the detectors are processed according to a time scheme; and the measurement results are corrected in a computer for normalizing the gains of the channels of the system. The mathematical model can serve as the basis for developing a method of calculating the optimal parameters of a multichannel radiometric system with visualization ...

40

A planar circular detector based on multiple point chemi- or bio-luminescent source within a coaxial cylindrical reactor  

British Library Electronic Table of Contents (United Kingdom)

An analytical method was proposed for calculating radiative fluxes incident on a planar circular detector from a volume multiple point chemi- or bio-luminescent source inside a coaxial cylindrical reactor. The method was designed for a cylindrical reactor when the surface reflections were neglected and when chemi- or bio-luminescence reaches a detector embedded in the same homogeneous optical medium as the point emitters of the volume multiple point source model. The radiative fluxes from arbitrarily distributed point emitters were expressed by one generalized quadruple-integral formula. Then some double- and single-integral formulas were obtained for calculating radiative fluxes from identically radiating point emitters uniformly distributed within the reactor. Selected results were compu...

2009-01-01

41

Procedure for radiation dose control in irradiated tissues during electron-beam therapy  

International Nuclear Information System (INIS)

The invention refers a procedure of radiation dose control in irradiated tissues during electron-beam therapy. It aims at meeting the planned radiation dose for diseased tissues and taking care of the healthy ones. Therefore, the dose distribution required is determined before irradiation in consideration of such factors as energy-dependence of detector sensitivity, self-absorption within the tissue, and relative biological effectiveness. Furthermore, the expected intensity distribution of secondary quantum radiation excited in the irradiated tissue is calculated. A radiation detector for local resolution is used for registration. During irradiation the calculated intensity distribution is compared with the measured one. The invention is applicable in radiation therapy with monoenergetic electron beams.

1984-11-08

42

Detection of explosives  

Energy Technology Data Exchange (ETDEWEB)

An analyser for detecting explosives has at least one neutron source and a plurality of gamma ray detectors. An article to be analysed is moved adjacent the source and detectors and is subjected to neutrons which generate gamma rays from any nitrogen in the article. The gamma rays are detected and analysed to determine the nitrogen concentration within the article. In order to achieve an area of uniform detection there are a plurality of detectors equidistant both from the or each source and from the article to be analysed. In order to avoid a decrease in sensitivity away from the source(s) and detectors there may be a second opposing array of source(s) and detectors on the opposite side of the article. For greatest uniformity of detection, a source in one array opposes a detector in the other array and vice versa. Transmission of radiation ...

1991-03-13

43

A new method of imaging particle tracks in solid state nuclear track detectors  

British Library Electronic Table of Contents (United Kingdom)

Summary Solid state nuclear track detectors are used to determine the concentration of a particles in the environment. The standard method for assessing exposed detectors involves 2D image analysis. However 3D imaging has the potential to provide additional information relating to angle as well as to differentiate clustered hit sequences and possibly energy of a particles but this could be time consuming. Here we describe a new method for rapid high-resolution 3D imaging of solid state nuclear track detectors. A `LEXT' OLS3100 confocal laser scanning microscope (Olympus Corporation, Tokyo, Japan) was used in confocal mode to successfully obtain 3D image data on four CR-39 plastic detectors. Three-dimensional visualization and image analysis enabled characterization of track features. This ...

2010-01-01

45

Enhancement of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 (16N) and Oxygen-19 (19O) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of 19O and 16N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high ambient radiation level even though sensitivity is appreciably good. For ...

2006-11-13

46

Plane electrode device for multiwire detector for ionizing radiations  

International Nuclear Information System (INIS)

A multiwire proportional counter type detector with thin slits instead of wires is presented. It can detect either charged particles (positive or negative) or radiation. The detector can be used as a counter or as an image converter. In radiography, it can replace photographic film or TV camera systems. It can also be used to measure particle or radiation energy. The slits which replace wires in the anode are introduced between two parallel microstrip conductors with different potentials. A quasi-polar electric field is produced between these strips. To obtain high fields, the slits are extremely narrow. Microstrips less than a micron can be obtained, giving structural dimensions of a few microns, i.e., 100 times smaller than the spacing in a classic wire anode.

1986-07-01

47

Circumsolar radiation telescope  

Energy Technology Data Exchange (ETDEWEB)

A circumsolar telescope for determining the flux of energy from the sun and from the circumsolar region as a function of angle, wavelength, and atmospheric conditions is presented. The telescope system consists of a specially designed scanning telescope, an electronic control and recording system and some auxiliary equipment. The detector is a pyroelectric crystal, a type of thermal detector, thus the fundamental measurement is relatively wavelength insensitive. The telescope is designed to provide data for all weather conditions during which a concentrating solar energy system would be operating. Analyses show that for a clear blue sky, the amount of radiation coming directly from the sun, while for a sky with thin clouds or haze, the circumsolar radiation is some 25% of the direct solar radiation. Under such conditions a measure of the circumsolar radiation is ...

1980-01-01

48

Radiometric analysis of raw materials and end products in the Turkish ceramics industry  

International Nuclear Information System (INIS)

This study presents the findings of radiometric analysis carried out to determine the activity concentrations of natural radionuclides in raw materials (clay, kaolin, quartz, feldspar, dolomite, alumina, bauxite, zirconium minerals, red mud and frit) and end products (glazed ceramic wall and floor tiles) in the Turkish ceramics industry. Hundred forty-six samples were obtained from various manufacturers and suppliers throughout the country and analyzed using gamma-ray spectrometer with HPGe detectors. Radiological parameters such as radium equivalent activity, activity concentration index and alpha index were calculated to assess the radiological aspects of the use of the ceramic end products as decorative or covering materials in construction sector. Results obtained were examined in the light of the relevant national and international legislation and guidance and compared with the results of similar studies reported in different countries. ...

2011-05-01

49

Acceptance testing in digital systems of mammography. Protocols applicability  

International Nuclear Information System (INIS)

Acceptance testing of mammographic imaging systems technical is the first approach in order to guarantee that mammograms will be achieved with the minimum radiation dose compatible with an image quality suitable for diagnose purposes. The aim of this study is to assess the practical applicability of different protocols in acceptance test of digital mammographic systems. This study has been carried out on the results of the acceptance tests of five flat panel digital mammographic systems. Parameters established in the systems technical specifications and those evaluated in the consulted protocols were tested. Due to the fact that the legislation in our country does not demand to consider a specific protocol, the results obtained were also compared considering different existing protocols. Results show discrepancies between manufacturers limiting values and those established in the protocols. Some parameters, such as the automatic exposure ...

50

Nuclear borehole logging using lithium detector assemblies  

International Nuclear Information System (INIS)

A method and apparatus for nuclear borehole logging, and in particular, neutron porosity logging, uses a neutron source, and a pair of spaced lithium detectors, preferably Li"6I crystal or Li"6 doped glass, to detect neutrons emitted from a borehole formation being logged. The spectrum developed by the lithium detectors is processed to remove the gamma ray background radiation and the hydrogen absorption peak, thus allowing a more accurate neutron count. A Gaussian curve is fitted to the neutron peak of the spectrum, the curve eliminating the hydrogen absorption peak. The area under this Gaussian curve represents the neutron count. (author).

1991-11-01

51

Applications of the Long-Range Alpha Detector (LRAD) technology to low-level radioactive waste management  

Energy Technology Data Exchange (ETDEWEB)

Long-Range Alpha Detector (LRAD) systems are designed to monitor alpha contamination by measuring the number of ions in the air. Alpha particles are a form of ionizing radiation and a typical 5-MeV alpha particle will create about 150,000 ion pairs in air. Field tests at various DOE sites have shown that LRAD Surface Soil Monitors (SSM), Sample Monitors, and Object Monitors are faster and more sensitive than traditional alpha detectors for measuring alpha contamination. This paper discusses the various applications of LRAD technology to low-level radioactive waste management.

1993-12-01

52

Silicon Detector Letter of Intent  

Energy Technology Data Exchange (ETDEWEB)

This document presents the current status of SiD's effort to develop an optimized design for an experiment at the International Linear Collider. It presents detailed discussions of each of SiD's various subsystems, an overview of the full GEANT4 description of SiD, the status of newly developed tracking and calorimeter reconstruction algorithms, studies of subsystem performance based on these tools, results of physics benchmarking analyses, an estimate of the cost of the detector, and an assessment of the detector R&D needed to provide the technical basis for an optimised SiD.

2010-05-26

53

Experimental Evaluation And Simulation Of Multi-pixel Cadmium-zinc-telluride Hard-x-ray Detectors  

CERN Document Server

This dissertation describes the evaluation of many-pixel Cadmium-Zinc-Telluride (CdZnTe) hard-X-ray detectors for future use with the High Energy Replicated Optics (HERO) telescope being developed at Marshall Space Flight Center. The detector requirements for the HERO application are good energy resolution (sufficient to resolve cyclotron features and nuclear lines), spatial resolution of ∼200 μm, minimal charge loss of absorbed X rays, and minimal sensitivity to the background environment. This research concentrates on assessing the suitability of these detectors for the focus of HERO, and includes the development of a simulation of the physics involved in an X-ray-detector interaction, a study of the intrinsic material properties, measurements with prototype detectors such as the energy and spatial resolution, charge loss, and X-ray background ...

2004-01-01

54

An imaging. gamma. -ray detector with scatter rejection for beam position control in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

An imaging detector for {gamma}-rays ({approx equal}1 MeV) based on minicell MWPCs with converters and a position resolution of {Delta}x=0.5 mm has been developed and tested. Very high rate capability (>10{sup 8}/cm{sup 2} s) and a special readout for suppression of scattered radiation are implemented allowing to enhance the measured contrast. The relevant physical processes are discussed and first pictures are presented. (orig.).

1991-12-01

55

Radiation hardness of plastic scintillating fiber against fast neutron and #gamma#-ray irradiation  

International Nuclear Information System (INIS)

In future collider experiments, where a background radiation level is estimated to be very high, e.g. around 10"2 #approx# 10"5 Gy/yr and 10"1"1 #approx# 10"1"4 n/cm"2/yr at SSC, the detectors operating around the collision point in the experiments will encounter a considerable amount of radiation. Therefore, the detectors, especially the calorimeter, are required to be resistive against high radiation levels. From this point of view, it is of great importance to study the effects of radiation damage on the performance of the detectors. The authors report preliminary results of measurements of radiation hardness of the plastic scintillating fiber Kuraray SCSF-81 against irradiation with fast neutrons and "6"0Co #gamma#-rays in the region of the neutron fluence from 1 x 10"1"1 to 5 x 10"1"3 n/cm"2 and the integrated ...

1992-10-25

56

Study on reactivity measurement by the Feynman-#alpha# method  

International Nuclear Information System (INIS)

The Feynman-#alpha# method was applied to measurement of reactivity and the ability of this method for a real-time reactivity monitoring system was assessed. In the experiment, all measured data by BF_3 detectors were stored in a multi-channel scaler controlled by a personal computer, and they were analyzed to obtain prompt neutron decay constant (#alpha#) and reactivity with consideration of dead time of detector. It was found that #alpha# could be obtained almost in a real-time even for both positive and negative reactivities by the present experimental technique. (author).

1996-09-01

57

Performance assessment for EEG-based neonatal seizure detectors  

UK PubMed Central (United Kingdom)

ObjectiveThis study discusses an appropriate framework to measure system performance for the task of neonatal seizure detection using EEG. The framework is used to present an extended...Full Text Available

2011-03-01

58

Performance of the transition radiation detector flown on the NMSU/WIZARD TS93 balloon-borne instrument  

Energy Technology Data Exchange (ETDEWEB)

It is built and tested a transition radiation detector (TRD) to discriminate positrons from protons in the balloon flight TS 93 experiment. It is presented the TRD performance using flight data obtaining a proton-positron rejection factor of the order of 10{sup -3}. During the 24 hour flight, the data in the momentum range 4-50 GeV/c are collected. Using the TRD together with the Silicon calorimeter, it is achieved an overall rejection factor of about 10{sup -5} of positron against the proton background over the entire momentum range.

1995-09-01

59

Superconducting strip detectors as position sensitive particle detectors  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of using of current-biased superconducting strips for radiation detection is investigated. Narrow Ta strips are exposed to 5.5 MeV [alpha]-particle radiation and the rise-time of the induced voltage pulses is measured as function of temperature and bias current. The rise-time of the voltage signal strongly depends on the site on the strip which is hit by the [alpha]-particle. In order to determine the spatial resolution of a superconducting strip detector, position-sensitive measurements were performed. The maximum lateral resolution estimated so far is 25[mu]m in a 7[mu]m wide, 340 nm thick and 0.6 mm long Ta-strip. (orig.)

1994-02-01

60

Particle and X-ray damage in pn-CCDs  

Energy Technology Data Exchange (ETDEWEB)

The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.

2000-01-11

61

Single event effects in the pixel readout chip for BTeV  

Energy Technology Data Exchange (ETDEWEB)

In future experiments the readout electronics for pixel detectors is required to be resistant to a very high radiation level. In this paper we report on irradiation tests performed on several preFPIX2 prototype pixel readout chips for the BTeV experiment exposed to a 200 MeV proton beam. The prototype chips have been implemented in commercial 0.25 {micro}m CMOS processes following radiation tolerant design rules. The results show that this ASIC design tolerates a large total radiation dose, and that radiation induced Single Event Effects occur at a manageable level.

2001-12-07

62

Analysis of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For ...

2005-11-23

63

Advanced radiation detector development: Advanced semiconductor detector development: Development of a oom-temperature, gamma ray detector using gallium arsenide to develop an electrode detector  

Energy Technology Data Exchange (ETDEWEB)

The advanced detector development project at the University of Michigan has completed the first full year of its current funding. Our general goals are the development of radiation detectors and spectrometers that are capable of portable room temperature operation. Over the past 12 months, we have worked primarily in the development of semiconductor spectrometers with {open_quotes}single carrier{close_quotes} response that offer the promise of room temperature operation and good energy resolution in gamma ray spectroscopy. We have also begun a small scale effort at investigating the properties of a small non-spectroscopic detector system with directional characteristics that will allow identification of the approximate direction in which gamma rays are incident. These activities have made use of the extensive clean room facilities at the University of Michigan for semiconductor device fabrication, and ...

1995-11-01

64

New concepts in risk assessment for patients with radiological treatment  

International Nuclear Information System (INIS)

In radiation risk assessment it must be differentiated between somatic and genetic effect on the one hand as well as between stochastic and non-stochastic effect on the other. According to definitions of the ICRP report 26 the limit for the dose equivalent of all tissues prevents non-stochastic radiation effects. With stochastic radiation effects probably exist no threshold doses; therefore the ALARA principle must be applied concerning radiation protection. The individual risk by stochastic radiation effects in its linear, linear-quadratic and quadratic extrapolations, respectively, is discussed in detail. The effective stochastic dose equivalent (H/sub eff/) as well as collective dose and collective damage are outlined.

1986-01-01

65

Measurements and elimination of Cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry  

International Nuclear Information System (INIS)

In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component ...

2007-08-21

66

Health hazards to children due to the Chernobyl accident?  

International Nuclear Information System (INIS)

The article tries to assess the radiation effects as objectively as possible. In conclusion, some steps that should be taken in future are listed, as e.g.: continuous monitoring of the radioactivity levels in air and soil, and recording of data for complete information. Further, investigation and assessment of radiation exposure of children, especially in regions most heavily affected; radioactivity monitoring of the food and milk given to children, and scientific research into the problem by pediatrists, and determination of maximum acceptable radiation doses. (orig./HSCH).

67

Assessment of the efficacy of braking radiation beam formation of electron accelerators  

International Nuclear Information System (INIS)

Proceeding from analysis of the influence of parameters of the target-filter system on radiation-physical characteristics of braking radiation, some recommendations were issued for assessment of the forming systems of medical accelerators of electrons. A new criterion - a coefficient of the forming system efficacy - was introduced, characterizing a beam formation tract with relation to a whole set of radiotherapeutic problems.

68

Uncertainties of retrospective radon concentration measurements by multilayer surface trap detector  

Energy Technology Data Exchange (ETDEWEB)

The detector for retrospective radon exposure measurements is developed. The detector consists of the multilayer package of solid-state nuclear track detectors LR-115 type. Nitrocellulose films works both as {alpha}-particle detector and as absorber decreasing the energy of {alpha}-particles. The uncertainties of implanted {sup 210}Pb measurements by two- and three-layer detectors are assessed in dependence on surface {sup 210}Po activity and gross background activity of the glass. The generalized compartment behavior model of radon decay products in the room atmosphere was developed and verified. It is shown that the most influencing parameters on the value of conversion coefficient from {sup 210}Po surface activity to average radon concentration are aerosol particles concentration, deposition velocity of unattached {sup 218}Po and air exchange rate. It is ...

2006-07-01

69

Facility for studying photon-neutron reactions under a beam of braking radiation  

International Nuclear Information System (INIS)

A facility for studying photon-neutron reactions under a braking #gamma#-beam with an energy of up to 26 MeV from a betratron includes Saratov-2, SM-4A, and IBM AT-386 microcomputers. Neutron detectors, pulsed braking radiation dosimeters, and the devices to control the betatron energy are described.

70

Characterization and Source Term Assessments of Radioactive Particles from Marshall Islands Using Non-Destructive Analytical Techniques  

Energy Technology Data Exchange (ETDEWEB)

A considerable fraction of radioactivity entering the environment from different nuclear events is associated with particles. The impact of these events can only be fully assessed where there is some knowledge about the mobility of particle bound radionuclides entering the environment. The behavior of particulate radionuclides is dependent on several factors, including the physical, chemical and redox state of the environment, the characteristics of the particles (e.g., the chemical composition, crystallinity and particle size) and on the oxidative state of radionuclides contained in the particles. Six plutonium-containing particles stemming from Runit Island soil (Marshall Islands) were characterized using non-destructive analytical and microanalytical methods. By determining the activity of {sup 239,240}Pu and {sup 241}Am isotopes from their gamma peaks structural information related to Pu matrix was obtained, and the source term was revealed. Composition and ...

2005-06-11

71

Image-based modeling of tumor shrinkage in head and neck radiation therapy1  

UK PubMed Central (United Kingdom)

Purpose: Understanding the kinetics of tumor growth∕shrinkage represents a critical step in quantitative assessment of therapeutics and realization of adaptive radiation therapy....Full Text Available

2010-05-01

72

Further assessment of the effects of occupational radiation exposure in the United Kingdom Atomic Energy Authority mortality study.  

UK PubMed Central (United Kingdom)

The United Kingdom Atomic Energy Authority mortality study was designed to investigate the relation between exposure to ionising radiation and mortality among the authority's employees. The present...Full Text Available

1987-03-01

73

Epidemiological survey of the effects of low level radiation dose: a comparative assessment  

Energy Technology Data Exchange (ETDEWEB)

This volume presents the collations tables of a six volume comparative epidemiological survey of the effects of low level radiation dose. Data are collated for the effects observed in the following irradiated groups:- Preconception irradiation, intra-uterine irradiation, childhood irradiation, adult irradiation. (UK).

1993-10-01

74

Electron spin resonance studies of radiation effects in biological materials. An assessment of current and future research  

Energy Technology Data Exchange (ETDEWEB)

Electron spin resonance spectroscopy can provide a powerful approach to the study of radiation effects in biological materials. This memorandum gives an overview of current and future research. (author).

1987-06-01

75

Advanced MRI Methods for Assessment of Chronic Liver Disease  

UK PubMed Central (United Kingdom)

MRI plays an increasingly important role for assessment of patients with chronic liver disease. MRI has numerous advantages, including lack of ionizing radiation and the possibility of performing...Full Text Available

2009-07-01

76

Boron-Lined Neutron Detector Measurements  

Energy Technology Data Exchange (ETDEWEB)

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. Reported here are the results of ...

2009-11-02

77

Use of the WNR spallation neutron source at LAMPF to determine the absolute efficiency of a neutron scintillation detector  

Energy Technology Data Exchange (ETDEWEB)

Prompt fission neutron spectrum measurements at the University of Massachusetts Lowell 5.5 MV Van de Graaff accelerator laboratory require that the neutron detector efficiency be well known over a neutron energy range of 100 keV to 20 MeV. The efficiency of the detector, has been determined for energies greater than 5.0 MeV using the Weapons Neutron Research (WNR) white neutron source at the Los Alamos Meson Physics Facility (LAMPF) in a pulsed beam, time-of-flight (TOF) experiment. Carbon matched polyethylene and graphite scatterers were used to obtain a hydrogen spectrum. The detector efficiency was determined using the well known H(n,n) scattering cross section. Results are compared to the detector efficiency calculation program SCINFUL available from the Radiation Shielding Information Center at Oak Ridge National Laboratory.

1994-06-01

78

GaAs Blocked-Impurity-Band Detectors for Far-Infrared Astronomy  

Energy Technology Data Exchange (ETDEWEB)

High-purity and doped GaAs films have been grown by Liquid-phase epitaxy (LPE) for development of a blocked impurity band (BIB) detector for far-infrared radiation. The film growth process developed has resulted in the capability to grow GaAs with a net active impurity concentration below 1 x 10{sup 13} cm{sup -3}, ideal for the blocking layer of the BIB detector. The growth of n-type LPE GaAs films with donor concentrations below the metal-insulator transition, as required for the absorbing layer of a BIB detector, has been achieved. The control of the donor concentration, however, was found to be insufficient for detector production. The growth by LPE of a high-purity film onto a commercially grown vapor-phase epitaxial (VPE) n-type GaAs doped absorbing layer resulted in a BIB device that showed a significant reduction in the low-temperature dark current compared to the absorbing ...

2004-12-21

79

X-ray imaging dose due to the digital imaging devices used in radiation therapy for patient positioning and repositioning: How to take it into account?; Les doses dues a l'imagerie numerique pour le controle de positionnement du patient en radiotherapie: comment les prendre en compte?  

Energy Technology Data Exchange (ETDEWEB)

The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)

2008-12-15

80

Acoustic response of piezoelectric lead-zirconate-titanate to a 400MeV/n xenon beam  

Energy Technology Data Exchange (ETDEWEB)

Characteristics of lead-zirconate-titanate (PZT) elements were studied by directly irradiating them with a 400 MeV/n Xe beam. The elements were sensitive to 10{sup 4} Xe ions and their output amplitudes were proportional to the beam intensity. An ensemble of those output amplitudes displayed a Bragg-curve-like response towards the range of 400 MeV/n Xe ion. We discuss the potential of PZT elements as a radiation detector and their application to high-intensity and high-energy detectors. (author)

2003-03-01

81

A new type active personal dosemeter with a solid state detector  

International Nuclear Information System (INIS)

We have developed a new type personal dosemeter by using a B-10 doped silicon p-n junction detector with a polyethylene radiator and a polyethylene moderator. The purpose of this study was to develop a real time neutron dosemeter with a nearly flat response in the energy range from thermal to 15 MeV and low angular dependence to the incident neutron direction. The neutron response of the dosemeter was obtained with the Monte Carlo calculation and the monoenergetic neutron experiment in a free air field and also under a condition attached on a phantom.

1988-04-01

82

Some considerations about future interferometric GW detectors  

International Nuclear Information System (INIS)

The two most important issues in designing future gravitational wave interferometric detectors are, in our opinion, thermal and optical noise. In this paper we discuss some approaches for reducing these noises. About thermal noise we show a possible cryogenic solution. About optical noise (namely, the combined effect of shot noise and radiation pressure noise) we show that it is possible to apply a recently proposed reduction strategy based on a 'quantum feedback' (Courty et al 2003 Phys. Rev. Lett. 90 083601; Courty et al 2003 Preprint gr-qc/0301068) to a full Fabry-Perot cavity. This can be seen as a further step towards the practical realization of a detector which is able to evade the standard quantum limit.

2004-03-07

83

Quartz fiber calorimetry and calorimeters  

CERN Document Server

Quartz fiber calorimetry is a technique the signal generation mechanism of which is based on the Cherenkov effect. In this article we try to give a comprehensive overview of the subject. We start with a general introduction to calorimetry where the basic elements that characterize the development of electromagnetic and hadronic showers are discussed. Then we describe in detail the operation principle and the properties of calorimeters equipped with quartz fibers. The main advantages of this type of calorimeters are the radiation hardness, the fast response and the compact detector dimensions, features that derive from the quartz material and the specific mechanism of operation. A section is devoted to presenting the quartz fiber calorimeters that have been built or planned to in various experiments to operate as centrality detectors, trigger detectors, luminosity monitors or general purpose very forward ...

2004-01-01

84

Measurement of radon daughter product burden by TLD dosemeters  

International Nuclear Information System (INIS)

A miniature device is described for measuring integral potential alpha energy concentration of radon daughter products (Csub(Rn)) for personnel and stationary dosimetry. The measuring apparatus consists of an air sampler, filters and TLD detectors. CaSO_4:Dy-teflon pellets were used as the detectors which registrate #gamma# radiation as well. The TLD-effect dependence on the potential alpha energy, as well as the fading of the detectors at 20-60 deg C after 170 hrs operation are presentd. The fading up to 40 deg C has been found to be negligible. The dosimeter may be used to measure Csub(Rh) starting with the 10"5 MeVxh/1 threshold, the accuracy being not worse than +-30%.

85

Ion beam induced charge imaging of epitaxial GaN detectors  

Energy Technology Data Exchange (ETDEWEB)

We report the use of ion beam induced charge imaging to characterise the charge signal uniformity of epitaxial gallium nitride radiation detectors. The detectors were fabricated from 2 {mu}m thick semi-insulating gallium nitride, grown by MOCVD on a sapphire substrate. A carrier concentration of 1.4x10{sup 15} cm{sup -3} was measured using capacitance-voltage measurements. Ion beam induced charge imaging was carried out with a 2 MeV alpha particle beam focussed to a 3 {mu}m diameter and raster scanned across the device. The resulting ion beam images show excellent charge signal uniformity in this material with no evidence of material defects or polycrystalline structure on the micrometer length scale. No evidence of charge signal trapping was observed in these devices.

2004-09-21

86

Indoor radon concentration measurements in some Spanish houses and dwellings with plastic nuclear track detectors  

Energy Technology Data Exchange (ETDEWEB)

A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a {sup 241}Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).

1991-01-01

87

Indoor radon concentration measurements in some Spanish houses and dwellings with plastic nuclear track detectors  

International Nuclear Information System (INIS)

A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a "2"4"1Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).

88

Thermal Design and Performance of the Gamma-Ray Spectrometer for the MESSENGER Spacecraft  

Energy Technology Data Exchange (ETDEWEB)

A gamma-ray spectrometer (GRS) has been built and delivered to the Mercury MESSENGER spacecraft which launched on August 3, 2004, from Cape Canaveral, Florida. The GRS, a part of seven scientific instruments on board MESSENGER, is based on a coaxial high-purity germanium detector. Gamma-ray detectors based on germanium have the advantage of providing excellent energy resolution, which is critical to achieving the science goals of the mission. However, germanium has the disadvantage that it must operate at cryogenic temperatures (typically {approx}80 K). This requirement is easy to satisfy in the laboratory but difficult near Mercury, which has an extremely hot thermal radiation environment. To cool the detector, a Stirling cycle mechanical cooler is employed. In addition, radiation and conduction techniques a are used to reduce the GRS heat load. Before delivering the flight sensor, ...

2004-10-13

89

Radioanalytical methods of rare earth element determination  

International Nuclear Information System (INIS)

Instrumental neutron activation analysis (INAA) and radionuclide X-ray fluorescence analysis (RXFA) were used for the determination of rare earth elements. For INAA, solution obtained by sample decomposition was dripped onto filter paper, enclosed and sealed into a polyethylene foil. The sample was activated in reactor WWR-S over a period of 4 to 6 hours with a neutron fluence of 10"1"3cm"-"2. Gamma radiation measurement was carried out with a planar and a coaxial HP-Ge detector in three decay periods. La, Ce, Nd, Sm, Eu, Gd, Tb, Ho, Tm, Yb and Lu were determined. The advantage of the method is its accuracy and high sensitivity, the disadvantage is the time-consuming analysis. The RXFA method was used as a rapid and operative method for the analysis of loose ore samples, aqueous and organic solutions of rare earth elements. For exciting X-ray radiation, "2"4"1Am was used and the radiation of K-lines was ...

1989-06-01

90

Development of a phoswich detector to detect neutrons in the charged-particle mixed field  

Energy Technology Data Exchange (ETDEWEB)

Manned-space missions bring an exposure due to corpuscular radiations of which nature is quite different from what we encounter in the ground environment. In the space environment, many secondaries are produced through interactions of cosmic ray primaries with the spacecraft wall and other surrounding materials. Among this large variety of radiation components in the space, the contribution of neutrons to the radiation exposure of astronauts has remained to be studied. Up to today, efforts to measure neutron dose equivalent have been made using passive detector systems. Considering uncertainties involved in current measurements and estimations of high energy neutrons, and their increasing importance for future manned missions, it is necessary to measure neutron spectrum in the spacecraft under realistic conditions. The neutron spectra have never been measured on board a spacecraft, because the neutron ...

1997-07-01

91

Application of a finite element method to leak before break (LBB) of a heat exchanger  

International Nuclear Information System (INIS)

The leak before break (LBB) concept is difficult to apply to a structure with a thin tube that is immersed in a water environment. A heat exchanger in a nuclear power plant is such a structure. The present paper addresses an application of the LBB concept to a heat exchanger in a nuclear power plant. The minimum leaked coolant amount containing the radioactive material which can activate the radiation detector device installed near the heat exchanger is assumed. The postulated initial flaw size that cannot grow to the critical flaw size within the time period to activate the radiation detector is justified. In this case, the radiation detector can activate the warning signal caused by coolant leakage from initially postulated flaws of the heat exchanger. The nuclear plant can safely shutdown when this occurs. Since the postulated initial flaw size can not grow ...

2003-08-17

92

Vacuum ultraviolet radiometry of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two quantities are combined to yield the radiant emittance at 147 nm ...

1995-10-01

93

Development of a computerized portal verification scheme for pelvic treatment fields  

International Nuclear Information System (INIS)

Purpose/Objective: At present, treatment verification between portal and reference images is performed based on manually-identified features by radiation oncologist, which is both time-consuming and potentially error-prone. There is a demand for the computerized verification procedure in clinical application. The purpose of this study is to develop a computerized portal verification scheme for pelvic treatment fields. Materials/Methods: The automated verification system involves image acquisition, image feature extraction, feature matching between reference and portal images and quantitative evaluation of patient setup. Electronic portal images with a matrix size of 256 x 256 and 12 bit gray levels were acquired using a liquid matrix electronic portal imaging device. Simulation images were acquired by digitizing simulation films using a TV camera into images with 256 x 256 matrix and 8 bit gray levels. Initially a Canny edge detector is applied ...

1996-09-01

94

Weakly penetrating radiation monitoring and assessment at Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

Weakly penetrating radiation monitoring and investigating with area monitors and individual dosimeters were carried out at Daya Bay nuclear power plant during its refueling outages. This paper introduces monitoring methods, measuring results, data analysis and assessment, presents some suggestions for monitoring plan and protection measures in the future as well. (authors)

2006-05-01

95

Assessment of internal contamination due to gamma emitters at nuclear power stations of Tarapur  

International Nuclear Information System (INIS)

Personal monitoring and dose assessment of all radiation workers is an essential regulatory requirement as per radiation safety procedures of AERB and operating stations. The occupational workers of TAPS 1 and 2 and TAPS 3 and 4 are monitored for internal contamination due to high energy gamma emitters by whole body counting

2010-02-03

96

Assessment of detector sensitivity and uniformity during SPECT rotation  

International Nuclear Information System (INIS)

The purpose of this research was to: a) evaluate variations in sensitivity and uniformity of SPECT detectors during 360"0 rotation, b) explore the causes of the variations and c) to discuss a correction procedure. A flood source consisting of a lucite disc 47.7 cm in diameter containing 3 microcuries of Co-57 was constructed. This source can be firmly attached to the uncollimated detector guaranteeing no detector-source geometry change during rotation. Four different SPECT cameras were tested. Measurements were obtained at 45"0 intervals throughout a 360"0 rotation, and repeated in 3 different orientations with respect to the earth's magnetic field. In one camera the effects of the direction and strength of induced magnetic fields were studied. All detectors showed cyclic rotational variations in sensitivity; in three cameras 6%, in one 3%. The amplitude and phase of the sensitivity variation curves and ...

1984-06-05

97

Gamma-rays and neutrinos from the pulsar wind nebulae  

Energy Technology Data Exchange (ETDEWEB)

We construct the time-dependent radiation model for the pulsar wind nebulae (PWNe), assuming that leptons are accelerated in resonant scattering with heavy nuclei, which are injected into the nebula by the pulsar. The equilibrium spectra of these particles inside the nebula are calculated taking into account their radiation and adiabatic energy losses. The spectra of {gamma}-rays produced by these particles are compared with the observations of the PWNe emitting TeV {gamma}-rays and predictions are made for the expected {gamma}-ray fluxes from other PWNe. Expected neutrino fluxes and neutrino event rates in a 1 km{sup 2} neutrino detector from these nebulae are also calculated. It is concluded that only the Crab Nebula can produce a detectable neutrino event rate in the 1 km{sup 2} neutrino detector. Other PWNe can emit TeV {gamma}-rays on the level of a few percent of that observed from the Crab ...

2005-08-01

98

Conceptual design of a low-temperature radiation-hard tracker detector  

CERN Document Server

Silicon sensors have about ten times improved radiation hardness around 130 K temperature, compared with the state-of-art sensors close to room temperature. This is based on the Lazarus effect studied by the RD39 Collaboration of CERN. Other benefits of low temperatures will also be discussed. We shall describe the conceptual design of low-mass detector modules cooled using two-phase flow of argon in miniature cooling pipes integrated in the module structure between the sensors and the readout hybrid circuit. The main engineering features of the cooling system and mechanical support structures are discussed, as well as the benefits arising from the operation of the tracker under cryogenic vacuum. 4 Refs.

2003-01-01

99

An integrating dosimeter for pulsed radiation  

Science.gov (United States)

A Pulsed Radiation Dosimetry System designed to measure radiation produced by particle accelerators is described. The problems associated with total-dose measurement of irregular shaped pulses of ionizing radiation have been simplified. The system responds to extremely narrow pulses of charged particles or X-rays using a pin diode as the detector. Direct readout of dose in rads (Si) is displayed on a 3-1/2 digit digital panel meter. The system will operate in either the multiple-pulse or single-pulse mode. The multiple-pulse mode would be useful in monitoring or tuning a linear accelerator. In the single-pulse mode the system will automatically display total dose of a transient event in real time and hold that measurement indefinitely or until the next measurement is made. The system features an automatic reset in either mode.

1983-12-01

100

Risk assessment for radiation protection purposes  

International Nuclear Information System (INIS)

In defining criteria for good protection against ionizing radiation, it is important to assess quantitatively the likely risk of any radiation exposure. The 'somatic' risks to the individual result mainly from induction of cancer in the organs irradiated, and these risks can now be estimated on the basis of numerous detailed epidemiological surveys of exposed human populations. Estimates of the risk of hereditary effects, from genetic changes induced in germ cells, are based largely on the frequency with which such effects are induced in other species. In both cases the risk at very low dose can be inferred using knowledge of the way in which radiation damage is caused in tissues. Coherent systems of radiation protection are based on a restriction of doses to the whole body and to individual organs, such that the induction of cancer and genetic harm is infrequent, and the threshold ...

1980-01-01

101

An Assessment of the Detection of Highly Enriched Uranium and its Use in an Improvised Nuclear Device using the Monte Carlo Computer Code MCNP-5  

Science.gov (United States)

In 2002 and again in 2003, an investigative journalist unit at ABC News transported a 6.8 kilogram metallic slug of depleted uranium (DU) via shipping container from Istanbul, Turkey to Brooklyn, NY and from Jakarta, Indonesia to Long Beach, CA. Targeted inspection of these shipping containers by Department of Homeland Security (DHS) personnel, included the use of gamma-ray imaging, portal monitors and hand-held radiation detectors, did not uncover the hidden DU. Monte Carlo analysis of the gamma-ray intensity and spectrum of a DU slug and one consisting of highly-enriched uranium (HEU) showed that DU was a proper surrogate for testing the ability of DHS to detect the illicit transport of HEU. Our analysis using MCNP-5 illustrated the ease of fully shielding an HEU sample to avoid detection. The assembly of an Improvised Nuclear Device (IND) -- a crude atomic bomb -- from sub-critical pieces of HEU metal was then examined via Monte Carlo ...

2007-04-01

102

Developing a regulatory performance assessment approach for geological disposal of spent nuclear fuel  

International Nuclear Information System (INIS)

To be able to carry out review functions regulatory authorities must be able to make critical evaluations of proponent's safety cases. In Sweden the Swedish Radiation Safety Authority aims to have in place its own suite of performance assessment tools. This paper looks at the role and application of a regulator's models to important features of current modelling in a proponent's performance assessment. (authors)

103

Nuclear radiation detectors on II-VI compounds  

International Nuclear Information System (INIS)

Nuclear radiation detectors in integral execution were produced by successive epitaxial growth from vapor phase of Zn Te and Cd Se thin layers onto scintillating Zn Se (Te) crystals. The irradiation of combined Zn Se (Te) - Zn Te - Cd Se detectors by Cu_K_a X-rays leads to the appearance of photoreceiver e.m.f., which tends to saturation with the increase of X-ray radiation dose reaching the value of 0.34-0.40 V at 200 R/min. The short circuit current dependence of irradiation dose power is linear. The matching factor for detectors with Zn Te-Cd Se photoreceivers with different doping levels is 0.68-0.92. The absolute monochromatic sensitivity is 0.32-0.35 m A/m W at a quantum efficiency 0.58-0.61 and a time constant 2 x 10"-"4 s. The calculated dose sensitivity for Zn Se(Te)-Zn Te-Cd Se combined detectors at the irradiation with X-rays having effective energy ...

1993-10-13

104

3. Physical foundations and methodology of radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The physical foundations are described of radionuclide X-ray fluorescence analysis (RXFA) and the table shows the values of K- and L-absorption thresholds and the K- and L-line energies of elements. The calculation of the intensity of characteristic radiation during RXFA proceeds from relations derived for conventional X-ray fluorescence analysis. The choice of the radionuclide source is ruled by the nature of the analysed substance and the used detection technique. The diagram shows the areas of radionuclide sources and the energy of the fluorescence radiation of elements. The table shows the spectra of radionuclide sources suitable for the purposes of RXFA measured by semiconductor Si(Li) and Ge(Li) detectors. (ES).

1983-12-01

105

Optical Modelling of the HFI Instrument on Board the Planck Surveyor  

Science.gov (United States)

The PLANCK SURVEYOR is a European Space Agency satellite mission to image the very faint anisotropies in the temperature of the Cosmic Microwave Background (CMB) radiation. Maynooth is actively participating in an international collaboration of scientists involved with the optical design of the High Frequency Instrument (HFI). This paper outlines research which has been undertaken in Maynooth concerned with numerical modelling of the optical characteristics of the multi-frequency array of detectors making up the HFI instrument. In the study the commercial software package ZEMAX was used to model the coupling of the focal plane HFI detectors to the PLANCK telescope. This package is particularly useful in the optical design of PLANCK because of the powerful optimisation features of the software. It is thus possible to readily determine the optimum positioning of the detectors in the focal plane of the ...

1999-07-01

106

Front-End-Electronics Communication software for multiple detectors in the ALICE experiment  

Energy Technology Data Exchange (ETDEWEB)

In the ALICE experiment at CERN, the Detector Control System (DCS) employs several interacting software components to accomplish its task of ensuring the correct operation and monitoring of the experiment. This paper describes the Front-End-Electronics Communication (FeeCommunication) software and its role within the DCS. The FeeCommunication software's central task is passing configuration and monitoring data between the top level DCS process control and the field devices of several detectors within ALICE. The lowest level of the FeeCommunication software runs on the DCS boards, specialized embedded systems which are in direct contact with the field devices and are physically located within the detector. The middle and upper layers run on standard PC hardware located in the counting room or other external locations. This paper focuses on the design and implementation of the FeeCommunication software and the steps ...

2006-02-15

107

Quantum locking of mirrors in interferometric measurements  

International Nuclear Information System (INIS)

We discuss the use of active control to reduce mirror position fluctuations at the quantum level. We have shown in a recent experiment that it is possible to reduce the thermal noise of a mirror by measuring and controlling its motion with an optomechanical sensor based on a high-finesse optical cavity. This approach can be extended to lock the mirror motion at the quantum level, and to suppress the quantum effects of radiation pressure in interferometric measurements such as gravitational-wave detectors. The sensitivity improvement is furthermore independent of losses in the interferometer.

2004-03-07

108

P and e identification capabilities CAPRICE  

Energy Technology Data Exchange (ETDEWEB)

The cosmic antiparticle ring imaging Cherenkov experiment (CAPRICE) flew on a stratospheric balloon 8-9 August 1994 over northern Canada and collected data for more than 21 hours with less than 5 g/cm{sup 2} of residual atmosphere. The instrument includes a solid radiator RICH detector and an electromagnetic calorimeter for particle identification in the magnetic spectrometer. Preliminary antiproton and positron identification capabilities are presented.

1995-09-01

109

Estimation of errors provided with dead times of roentgen digital tomography  

International Nuclear Information System (INIS)

Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computer tomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained

110

Compton scatter tomography and its inversion using a few projections  

Energy Technology Data Exchange (ETDEWEB)

Compton scatter tomography utilizes the electronic collimation characteristics available through the Compton scattering angle-energy correlation to obtain tomographic images. In this work we present particular aspects of the technique, which are relevant to the inverse radiation transport problem of reducing marginal projection data to radial two-phase flow regime maps. The results indicate a viable technique for the tomographic imaging of tow-phase flow using practical source strengths and reasonably few detectors.

1988-01-01

111

A combined real time wide range energy neutron dosimeter and survey meter for high neutron dose rates with Si surface barrier detectors  

International Nuclear Information System (INIS)

The development of a flat response small size, real time neutron dosimeter and ratemeter for the energy range of about 1 eV to 14 MeV is presented. This dosimeter is adequate for measuring neutron dose equivalents of 3 mRem up to 100 Rem and dose rates of 300 mRem/h to 50 Rem/h or more. The dosimeter consists of four Si surface barrier detectors. _1_0B radiators are placed in front of three of the detectors and a polyethylene radiator is placed in front of the fourth one. The _1_0B pellets are used for dose equivalent measurements in the energy range 1 eV to proportional1 MeV. The polyethylene radiator, made in two parts having thicknesses of 10 and 100 mg/cm_2 in an area ratio of 8 to 1, flattens the response to +-40% in the energy range 1-14 MeV. The signal-to-background ratio for different Si surface barrier detectors and for _1_0B polyethylene ...

1983-06-01

112

Survey of radiation protection programmes for transport; Etude des programmes de radioprotection pour les transports de matieres radioactives  

Energy Technology Data Exchange (ETDEWEB)

The survey of radiation protection programmes for transport has been jointly performed by three scientific organisations I.P.S.N. (France), G.R.S. ( Germany), and N.R.P.B. (United kingdom) on behalf of the European Commission and the pertaining documentation summarises the findings and conclusions of the work that was undertaken with the principal objectives to provide guidance on the establishment, implementation and application of radiation protection programmes for the transport of radioactive materials by operators and the assessment and evaluation of such programmes by the competent authority and to review currently existing radiation protection programmes for the transport of radioactive materials. (N.C.)

2001-07-01

113

Radiological concepts in radiotherapy  

International Nuclear Information System (INIS)

The atomic explosions in Hiroshima and Nagasaki made the name radiation itself become a nightmare. Notwithstanding this, radiation continued to serve the mankind specially in diagnosis of several human diseases and in the treatment of intractable malignancies. With their latest research tools biologists have now shown a significant shift in the earlier paradigm; even the concept that radiation initiates cancer appears to be no longer tenable. On the contrary, selective radiation doses inhibit growth of cancer cells and radiation in combination with many chemotherapeutic drugs, radiosensitizing chemicals and/or hyperthermia, is emerging as a new modality for cancer treatment which offers high therapeutic advantages. In addition, the deleterious effects of radiation can now be strategically counter poised by the use of many drugs and chemicals. This has been ...

114

Boron-Lined Multichamber and Conventional Neutron Proportional Counter Tests  

Energy Technology Data Exchange (ETDEWEB)

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. These technologies are: 1) Boron ...

2010-09-07

115

Normalized noise power spectrum of full field digital mammography detector system  

International Nuclear Information System (INIS)

Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)

116

A VUV prism spectrometer for RICH radiator refractometry  

CERN Document Server

A prism spectrometer has been developed to operate in the VUV wavelength range from 120 to 200 nm. It can be used as a pre- disperser in conjunction with a Fabry-Perot based gas refractometer. This instrument has also been used to measure the refractive index of the liquid radiator C/sub 6/F/sub 14/ in various spectral lines. This radiator is used in the RICH detectors of the DELPHI experiment and has been proposed for ALICE, and LHCb experiments. The spectral resolution of the system is improved as the wavelength decreases and the data are consistent with a wavelength accuracy about 0.4 nm at 140 nm. The results for the dispersion curve of the above liquid are presented. (17 refs).

2000-01-01

117

SENSITIVITY STUDIES FOR AN IN-SITU PARTIAL DEFECT DETECTOR (PDET) IN SPENT FUEL USING MONTE CARLO TECHNIQUES  

Energy Technology Data Exchange (ETDEWEB)

This study presents results from Monte Carlo radiation transport calculations aimed at characterizing a novel methodology being developed to detect partial defects in Pressurized Water Reactor (PWR) spent fuel assemblies (SFAs). The methodology uses a combination of measured neutron and gamma fields inside a spent fuel assembly in an in-situ condition where no movement of the fuel assembly is required. Previous studies performed on single isolated assemblies resulted in a unique base signature that would change when some of the fuel in the assembly is replaced with dummy fuel. These studies indicate that this signature is still valid in the in-situ condition enhancing the prospect of building a practical tool, Partial Defect Detector (PDET), which can be used in the field for partial defect detection.

2008-04-28

118

Quantification of thin film crystallographic orientation using X-ray diffraction with an area detector  

Energy Technology Data Exchange (ETDEWEB)

As thin films become increasingly popular (for solar cells, LEDs, microelectronics, batteries), quantitative morphological information is needed to predict and optimize the film's electronic, optical and mechanical properties. This quantification can be obtained quickly and easily with X-ray diffraction using an area detector and synchrotron radiation in two simple geometries. In this paper, we describe a methodology for constructing complete pole figures for thin films with fiber texture (isotropic in-plane orientation). We demonstrate this technique on semicrystalline polymer films, self-assembled nanoparticle semiconductor films, and randomly-packed metallic nanoparticle films. This method can be immediately implemented to help understand the relationship between film processing and microstructure, enabling the development of better and less expensive electronic and optoelectronic devices.

2010-02-19

119

Programmable radionuclide X-ray fluorescence multi-channel spectrometric analyzer, type 123-1  

International Nuclear Information System (INIS)

The whole equipment consists of three separate portable parts: a detector case, a microprocessor and a graphic TV monitor. Magnetic tape memory and an x-y recorder can be connected for recording the measured spectra. The analyzer contains two built-in exchangeable excitation radionuclides. Fluorescence and scattered radiation is detected using a proportional detector. The detected pulses are analyzed by a 256-channel analyzer and the results are shown on the display. The device may be used in mining laboratories, coal and ore dressing plant control rooms or in mining fields of open cast mines for quick detection of the quality of mined or dressed raw materials. (E.S.). 1 fig.

1988-01-01

120

Comparison of energy flows in deep inelastic scattering events with and without a large rapidity gap  

Energy Technology Data Exchange (ETDEWEB)

Energy flows in deep inelastic electron-proton scattering are investigated at a centre-of-mass energy of 296 GeV for the range Q{sup 2}{>=}10 GeV{sup 2} using the ZEUS detector. A comparison is made between events with and without a large rapidity gap between the hadronic system and the proton direction. The energy flows, corrected for detector acceptance and resolution, are shown for these two classes of events in both the HERA laboratory frame and the Breit frame. From the differences in the shapes of these energy flows we conclude that QCD radiation is suppressed in the large-rapidity-gap events compared to the events without a large rapidity gap. (orig.)

1994-07-01

121

Naturally radioactive waste materials. Part 1. Assessment and monitoring of materials and residues  

International Nuclear Information System (INIS)

The amended Radiation Protection Ordinance of 2001 contains regulations on natural radioactive materials, whose recycling or disposal poses practical problems. There is little experience in this field so far.

2003-03-01

122

Assessment of tumour response in a rat rhabdomyosarcoma.  

UK PubMed Central (United Kingdom)

A rhabdomyosarcoma in a WAG/Rij rat with capacity for colony growth after tumour excision and enzymatic dissociation has been used to study response to high and low LET radiation. End points are tumor...Full Text Available

1980-04-01

123

Algorithm for assessment of mean annual gonad dose and genetically significant dose from the data of personal dosimetry  

International Nuclear Information System (INIS)

During one year more than 40,000 items of information on radiation exposure of personnel involved in the handling of radiation sources and more than 5,000,000 items on irradiation of other people are collected in the authors' laboratory. Considerable progress in assessment of mean annual gonad dose of genetically sifnificant dose was attained by means of an algorithm for a personal computer. This simple and inexpensive system has led to a higher accuracy in the application of protective measures. (author).

1985-10-22

127

A review of 4 norm industries in Ireland  

Energy Technology Data Exchange (ETDEWEB)

Full text: This presentation will review the progress achieved so far by the Irish national regulatory agency, the Radiological Protection Institut e of Ireland (R.P.I.I.) in the investigation of work activities where the presence of natural radiation sources (NORM) could lead to a significant increase in exposure to workers or members of the public which cannot be disregarded from the radiation protection point of view. Since the coming into force in Ma y 2000 of the Radiological Protection Act, 1991 (Ionising Radiation) Order, 2000 (S.I. No. 125 of 2000) which implements the Eu B.S.S. Directive 96/29/EURATOM, four major NORM industries currently active in Ireland have been investigated. According to the literature, they are all considered liable to involve work practices resulting in exposure to NORM. They include: the gas extraction and production industry, the peat- and coal-firing power generation industry and the ...

2006-07-01

128

A Radiation Laboratory Curriculum Development at Western Kentucky University  

Science.gov (United States)

We present the latest developments for the radiation laboratory curriculum at the Department of Physics and Astronomy of Western Kentucky University. During the last decade, the Applied Physics Institute (API) at WKU accumulated various equipment for radiation experimentation. This includes various neutron sources (computer controlled d-t and d-d neutron generators, and isotopic 252 Cf and PuBe sources), the set of gamma sources with various intensities, gamma detectors with various energy resolutions (NaI, BGO, GSO, LaBr and HPGe) and the 2.5-MeV Van de Graaff particle accelerator. XRF and XRD apparatuses are also available for students and members at the API. This equipment is currently used in numerous scientific and teaching activities. Members of the API also developed a set of laboratory activities for undergraduate students taking classes from the physics curriculum (Nuclear Physics, Atomic Physics, and ...

2009-03-10

129

Health risks arising from ionizing radiation and chemical pollutants  

International Nuclear Information System (INIS)

In quantifying health risks arising from radiation exposure and synergistic effects promoted by radiation the dose-effect relationship must be used as a basis. Special problems arise in the extrapolation of experimental results or in the treatment of data in the region of low doses administered over long periods of time. For radiation protection purposes, especially manifestations of cancer and genetic effects are significant. The International Commission on Radiation Protection has published binding guiding values on the basis of which to assess the risk of cancer. The cancer risk and genetic risks are estimated for relevant dose ranges and compared with other factors of civilization. For the most important chemical pollutants emitted into the environment the possibilities of impacts arising from synergistic effects are discussed on the basis of the rules and regulations specified ...

1979-10-03

130

Rest life time management of Kozloduy NPPP Unit 3 and 4  

International Nuclear Information System (INIS)

The radiation life time of reactor pressure vessel (RPV) is the most important limiting factor for the term of exploitation of the whole power unit. The main degradation mechanism of RPV metal is the neutron induced embrittlement. Processes of radiation ageing running in RPV metal lead to fracture toughness decrease and to increased probability of brittle fracture of the vessel under thermal shocks. This explains the importance of RPV integrity assessment and rest life time management

2002-11-04

131

Report of National Cancer Institute symposium: comparison of mechanisms of carcinogenesis by radiation and chemical agents. I. Common molecular mechanisms  

Science.gov (United States)

Some aspects of molecular mechanisms common to radiation and chemical carcinogenesis are discussed, particularly the DNA damage done by these agents. Emphasis is placed on epidemiological considerations and on dose-response models used in risk assessment to extrapolate from experimental data obtained at high doses to the effects from long-term, low-level exposures. 3 references, 6 figures. (ACR)

1984-01-01

132

Health and Safety Research Division progress report for the period October 1, 1991--March 31, 1993  

International Nuclear Information System (INIS)

This is a progress report from the Health and Safety Research Division of Oak Ridge National Laboratory. Information is presented in the following sections: Assessment Technology, Biological and Radiation Physics, Chemical Physics, Biomedical and Environmental Information Analysis, Risk Analysis, Center for Risk Management, Associate Laboratories for Excellence in Radiation Technology (ALERT), and Contributions to National and Lead Laboratory Programs and Assignments--Environmental Restoration.

1998-06-01

133

Radiative transfer in a solar absorbing particle laden flow  

Science.gov (United States)

A possible receiver configuration is a cavity in which a falling sheet of solid particles is directly irradiated by the concentrated solar flux passing through the aperture. Regardless of the particular geometry, the radiative transfer within the falling particle curtain must be studied in order to determine the net radiative heating rate for the particles. A discrete ordinate radiative transfer model has been developed to predict the radiative coupling within the falling particle curtain. The model determines how much energy is absorbed by the particles, how much is transmitted to the rear wall of the receiver, and determines the effects of particle scattering and thermal emission on the net radiation absorbed by the particles. The model accounts for the directional nature of the radiation field, particle scattering, and the wavelength dependence of the optical ...

1985-11-01

134

Radiation inactivation target size of rat adipocyte glucose transporters in the plasma membrane and intracellular pools  

Energy Technology Data Exchange (ETDEWEB)

The in situ assembly states of the glucose transport carrier protein in the plasma membrane and in the intracellular (microsomal) storage pool of rat adipocytes were assessed by studying radiation-induced inactivation of the D-glucose-sensitive cytochalasin B binding activities. High energy radiation inactivated the glucose-sensitive cytochalasin B binding of each of these membrane preparations by reducing the total number of the binding sites without affecting the dissociation constant. The reduction in total number of binding sites was analyzed as a function of radiation dose based on target theory, from which a radiation-sensitive mass (target size) was calculated. When the plasma membranes of insulin-treated adipocytes were used, a target size of approximately 58,000 daltons was obtained. For adipocyte microsomal membranes, we obtained target sizes of approximately 112,000 and ...

1987-06-15

135

Body weight-tailored contrast material injection protocol for 64-detector row computed tomography coronary angiography  

International Nuclear Information System (INIS)

The aim of this study was to assess the body weight-tailored contrast material injection protocol for 64-detector computed tomography (CT) to maintain optimal coronary CT attenuation. A total of 60 patients who underwent CT coronary angiography were assigned to one of three groups: protocol A, total of 0.7 ml kg"-"1 with 300 mg I/ml iodine concentration; protocol B, total of 0.6 ml kg"-"1 with 350 mg I/ml; protocol C, total of 0.7 ml kg"-"1 with 350 mg I/ml. The injection duration was 10 s in all patients. The proportion of intracoronary attenuation values >325 Hounsfield unit (HU) was compared on a per-vessel and per-patient basis. The attenuation value was significantly more likely to exceed 325 HU with protocol C (95% for reader 1 and 90% for reader 2) than with protocol A or B on the per-vessel analysis (P325 HU) with 64-detector CT when using an injection duration of 10 s. (author)

2011-01-01

136

Radiological hazards in uranium mines and a yellow-cake plant in Turkey  

Energy Technology Data Exchange (ETDEWEB)

Radiological hazard in uranium mining and milling operations are primarily due to exposure to external beta and gamma radiation as well as to airborne radionuclides which consist of radon and its short-lived daughter products. In May 1981 a radiological survey programme was performed in order to make a general assessment of the radiation hazards associated with the uranium mines and the Uranium Pilot Plant operated by the M.T.A. Institute in the Koprubasi district of the Manisa province. In this paper a preliminary radiological risk evaluation attempt is presented based on the radiation and radioactivity measurements performed in this district in May 1981.

1984-06-01

137

Choice of distance from radiation source to tested object for gamma-absorption density measurer in divergent pencil of ray  

International Nuclear Information System (INIS)

Formulae are derived for estimation of the effect of gamma beam divergence on the value of systematic and statistical components of the errors of density measurement in production of structural materials and products also in the process of exploitation of building structures and constructions. Engineering technique for choice of the distance between radiation source and object under test is developed for absorption radioisotope densimeter operating by the scheme of geometry of divergent beam with amplitude compensation of backscattered radiation effect. The assessment of radioisotope densimeter efficiency providing the error of density measurement prescribed at design stage

138

Radioactive decay data tables  

Energy Technology Data Exchange (ETDEWEB)

The estimation of radiation dose to man from either external or internal exposure to radionuclides requires a knowledge of the energies and intensities of the atomic and nuclear radiations emitted during the radioactive decay process. The availability of evaluated decay data for the large number of radionuclides of interest is thus of fundamental importance for radiation dosimetry. This handbook contains a compilation of decay data for approximately 500 radionuclides. These data constitute an evaluated data file constructed for use in the radiological assessment activities of the Technology Assessments Section of the Health and Safety Research Division at Oak Ridge National Laboratory. The radionuclides selected for this handbook include those occurring naturally in the environment, those of potential importance in routine or accidental releases from the nuclear fuel cycle, those of ...

1981-01-01

139

Assessment and control of fetal exposure  

Energy Technology Data Exchange (ETDEWEB)

The assessment and control of fetal exposure to radiation in the workplace is an issue that is complicated by both biological and political/social ramifications. As a result of the dramatic increase in the number of women employed as radiation workers during the past 10 years, many facilities using radioactive materials have instituted fetal protection programs with special requirements for female radiation workers. It is necessary, however, to ensure that any fetal protection program be developed in such a way as to be nondiscriminatory. A study has been initiated whose purpose is to balance the political/social and the biological ramifications associated with occupational protection of the developing embryo/fetus. Several considerations are involved in properly balancing these factors. These considerations include appropriate methods of declaring the pregnancy, training workers, controlling the dose ...

1991-10-01

140

Summary of the engineering assessment of inactive uranium mill tailings, Spook Site, Converse County, Wyoming  

Energy Technology Data Exchange (ETDEWEB)

Ford, Bacon, Davis Utah Inc. has reevaluated the Spook site in order to revise the December 1977 engineering assessment of the problems resulting from the existence of radioactive uranium mill tailings 48 mi northeast of Casper, in Converse County, Wyoming. This engineering assessment has included the preparation of topographic maps, the performance of core drillings and radiometric measurements sufficient to determine areas and volumes of tailings and radiation exposures of individuals and nearby populations, the investigations of site hydrology and meteorology, and the evaluation and costing of alternative corrective actions. Radon gas released from the 187,000 tons of tailings at the Spook site constitutes the most significant environmental impact, although windblown tailings and external gamma radiation also are factors.

1981-10-01

141

Engineering assessment of inactive uranium mill tailings, Tuba City site, Tuba City, Arizona  

Energy Technology Data Exchange (ETDEWEB)

Ford, Bacon and Davis Utah Inc. has reevaluated the Tuba City site in order to revise the March 1977 engineering assessment of the problems resulting from the existence of radioactive uranium mill tailings at Tuba City, Arizona. This engineering assessment has included the preparation of topographic maps, the performance of core drillings and radiometric measurements sufficient to determine areas and volumes of tailings and radiation exposures of individuals and nearby populations, the investigations of site hydrology and meteorology, and the evaluation and costing of alternative corrective actions. Radon gas released from the 0.8 million tons of tailings at the Tuba City site constitutes the most significant environmental impact, although windblown tailings and external gamma radiation also are factors.

1981-09-01

142

Analysis on Dose Distribution in Heterogeneous Condition for Narrow 6 MV X-ray Beams  

International Nuclear Information System (INIS)

Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous condition since the GAFCHROMICat..EBT ...

2010-10-01

143

A radionuclide analyzer of total sulfur in coal  

International Nuclear Information System (INIS)

The devised radionuclide analyzer for the determination of total sulfur in coal includes two radionuclide sources with different energies, which are accommodated in collimators fitted with adjustable diaphramgs. The sample compartment is located between the two sources. Moreover, an X-ray fluorescence standard can be slid into the sample compartment. A proportional detector for X-ray fluorescence and scattered gamma radiation is located off the sample compartment. The input of the proportional detector is interfaced to the output of a high-voltage supply, the output, to the information input of a control-and-evaluation unit. One of the control outputs of the control-and-evaluation unit is connected to the input of the sliding mechanism for the X-ray fluorescence standard. This arrangement enables automatic energy calibration of the analyzer. The analyzer can measure not only total sulfur in coal by radionuclide X-ray ...

1987-05-13

144

Year-long comparison of two techniques to monitor outdoor radon concentrations at Shiprock, New Mexico  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center (TMC) at the DOE Grand Junction Projects Office (GJPO) in Grand Junction, Colorado, to standardize, calibrate, and compare measurements made in support of DOE remedial action programs. Outdoor radon concentration measurements were made by the TMC in Shiprock, New Mexico, to compare two different methods of measuring radon in an attempt to determine the feasibility of using passive alpha-track detectors to assess the adequacy of remedial action undertaken at the Shiprock uranium mill tailings pile. The results of the first three quarters of monitoring have been detailed in previous reports. An analysis of the data from the fourth quarter of monitoring at Shiprock reveals a somewhat poorer correlation between the two sets of measurements than was seen in the third quarter of this study, but a better correlation than was ...

1988-08-01

145

Spectrochemical analysis using infrared multichannel detectors  

CERN Document Server

Spectrochemical analysis using infrared multichannel detectors

2007-01-01

146

CZT Detector and HXI Development at CASS/UCSD  

CERN Document Server

CZT Detector and HXI Development at CASS/UCSD

2006-01-01

147

ACT Lectures on Detectors - Trigger and Data Acquisition (5/5)  

CERN Document Server

ACT Lectures on Detectors - Trigger and Data Acquisition (5/5)

2011-01-01

148

Zinc determination in medicinal powders by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

X-ray fluorescence analysis was used to determine the zinc content of the ''Perilacin'' powder and the ZnO content of the ''Epiderman-pix'' powder. The characteristic Ksub(#alpha#) line of zinc was excited using a "1"4"7Pm/Mo source (10"7 s"-"1) and the molybdenum Ksub(#alpha#) line (17.47 keV). 4 to 5% Zn and 45 to 49% ZnO were determined with a NaI(Tl) scintillation detector. The radiation intensity was found to decrease with particle size. (M.K.).

1977-01-01

149

Radiation damage measurements in room temperature semiconductor radiation detectors  

Energy Technology Data Exchange (ETDEWEB)

The literature of radiation damage measurements on cadmium zinc telluride (CZT), cadmium telluride (CT), and mercuric iodide (HgI{sub 2}) is reviewed and in the case of CZT supplemented by new alpha particle data. CZT strip detectors exposed to intermediate energy (1.3 MeV) proton fluences exhibit increased interstrip leakage after 10{sup 10} p/cm{sup 2} and significant bulk leakage after 10{sup 12} p/cm{sup 2}. CZT exposed to 200 MeV protons shows a two-fold loss in energy resolution after a fluence of 5 {times} 10{sup 9} p/cm{sup 2} in thick (3 mm) planar devices but little effect in 2 mm devices. No energy resolution effects were noted from moderated fission spectrum of neutrons after fluences up to 10{sup 10} n/cm{sup 2}, although activation was evident. Exposures of CZT to 5 MeV alpha particle at fluences up to 1.5 {times} 10{sup 10} {alpha}/cm{sup 2} produced a near linear decrease in peak position with fluence and increases in FWHM ...

1998-12-01

150

Neutron resonances in /sup 100/Mo and valence neutron capture  

Science.gov (United States)

Neutron resonance interactions with /sup 100/Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% /sup 100/Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture ..gamma..-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.

1979-07-01

151

Multielement analysis of air samples  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A "2"3"8Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed. (author).

1981-01-01

152

Development of thin foil Faraday collector as a lost alpha particle diagnostic for high yield D-T tokamak fusion plasmas  

Energy Technology Data Exchange (ETDEWEB)

Alpha particle confinement is necessary for ignition of a D-T tokamak fusion plasma and for first wall protection. Due to high radiation backgrounds and temperatures, scintillators and semiconductor detectors may not be used to study alpha particles which are lost to the first wall during the D-T programs on JET and ITER. An alternative method of charged particle spectrometry capable of operation in these harsh environments, is proposed: it consists of thin foils of electrically isolated conductors with the flux of alpha particles determined by the positive current flowing from the foils. 2 refs., 3 figs.

1994-07-01

153

Artificial intelligence: the future in nuclear plant maintenance  

Energy Technology Data Exchange (ETDEWEB)

The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.

1984-12-01

154

Artificial intelligence: the future in nuclear plant maintenance  

International Nuclear Information System (INIS)

The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.

1984-09-23

155

Measurement of cumulative and independent yields of products from fission of sup(242m)Am induced by thermal neutrons  

Energy Technology Data Exchange (ETDEWEB)

Mass and charge distributions of products from fission of sup(242m)Am induced by thermal neutrons have been investigated by means of the semiconductor spectrometry of ..gamma.. radiation from a mixture of non-separated fragment nuclei. Specimens of the fissible material have been irradiated in the vertical experimental channel of the research reactor then the measurements have been performed with calibrated semiconductor detectors. Three experiments with substantially different irradiation times have been performed to expand the nomenclature of the investigated fission products. The spectra of ..gamma.. radiation from the mixture of fission products, and time dependences of the counting rates at the total absorption peaks have been handled with computers. The obtained yields are compared with data of previous investigations performed with different experimental methods, as well as with the calculated one.

1985-03-01

156

Measurement of K x-ray intensity ratio of tin, gadolinium and dysprosium  

International Nuclear Information System (INIS)

Full text: Measurement of K_#beta# to K_#alpha# x-ray intensity ratios are important not only in the field of atomic physics, radiation physics and medical physics, but also to test the validity of assumptions made in the theoretical prediction. The intensity ratios can also give information on the effect of physical and chemical environment of the element in the compound. Many investigators have adopted a single and double reflection geometries to measure the K_#beta# to K_#alpha# x ray intensity ratios to understand the effect of physical and chemical environment on x-ray fluorescence. The targets are excited by a radioactive source of having activity of the order 100 MBq. in order to carry out accurate measurement K_#beta# to K_#alpha# x-ray intensity ratios, we have develop 2#pi# geometrical configuration method : placing a target right on the surface of the detector facing the target to measure the K shell fluorescence parameters such as ...

2003-11-01

157

Short-term inhibition of ADP-induced platelet aggregation by clopidogrel ameliorates radiation-induced toxicity in rat small intestine.  

Science.gov (United States)

Endothelial dysfunction and increased platelet aggregation may be involved in the pathogenesis of normal tissue radiation toxicity. This study assessed clopidogrel, an inhibitor of ADP-induced platelet aggregation, as a modulator of intestinal radiation injury (radiation enteropathy). Rat small intestine was exposed to 21 Gy X-radiation. Clopidogrel (20 mg/kg/day) or vehicle was administered from 2 days before to 10 days after irradiation. Structural radiation injury, neutrophil infiltration, smooth muscle cell proliferation, collagen content, and TGF-beta1 expression were assessed 2 weeks (early phase) and 26 weeks (delayed phase) after irradiation, using quantitative histology and immunohistochemistry, morphometry, and real-time fluorogenic probe RT-PCR. Irradiated intestine exhibited significant histopathologic injury, reduced mucosal ...

2002-01-01

158

Radiation Isotope Identification Device (RIIDs) Field Test and Evaluation Campaign  

Energy Technology Data Exchange (ETDEWEB)

Handheld, backpack, and mobile sensors are elements of the Global Nuclear Detection System for the interdiction and control of illicit radiological and nuclear materials. They are used by the U.S. Department of Homeland Security (DHS) and other government agencies and organizations in various roles for border protection, law enforcement, and nonproliferation monitoring. In order to systematically document the operational performance of the common commercial off-the-shelf portable radiation detection systems, the DHS Domestic Nuclear Detection Office conducted a test and evaluation campaign conducted at the Nevada Test Site from January 18 to February 27, 2006. Named 'Anole', it was the first test of its kind in terms of technical design and test complexities. The Anole test results offer users information for selecting appropriate mission-specific portable radiation detection systems. The campaign also offered manufacturers ...

2007-08-01

159

Modulating factors in the expression of radiation-induced oncogenic transformation  

Energy Technology Data Exchange (ETDEWEB)

Many assays for oncogenic transformation have been developed ranging from those in established rodent cell lines where morphological alteration is scored, to those in human cells growing in nude mice where tumor invasiveness is scored. In general, systems that are most quantitaive are also the least relevant in terms of human carcinogenesis and human risk estimation. The development of cell culture systems has made it possible to assess at the cellular level the oncogenic potential of a variety of chemical, physical and viral agents. Cell culture systems afford the opportunity to identify factors and conditions that may prevent or enhance cellular transformation by radiation and chemicals. Permissive and protective factors in radiation-induced transformation include thyroid hormone and the tumor promoter TPA that increase the transformation incidence for a given dose of radiation, and retinoids, ...

1990-08-01

160

Modulating factors in the expression of radiation-induced oncogenic transformation  

International Nuclear Information System (INIS)

Many assays for oncogenic transformation have been developed ranging from those in established rodent cell lines where morphological alteration is scored, to those in human cells growing in nude mice where tumor invasiveness is scored. In general, systems that are most quantitaive are also the least relevant in terms of human carcinogenesis and human risk estimation. The development of cell culture systems has made it possible to assess at the cellular level the oncogenic potential of a variety of chemical, physical and viral agents. Cell culture systems afford the opportunity to identify factors and conditions that may prevent or enhance cellular transformation by radiation and chemicals. Permissive and protective factors in radiation-induced transformation include thyroid hormone and the tumor promoter TPA that increase the transformation incidence for a given dose of radiation, and retinoids, ...

1990-01-01

161

How to overestimate risks of ionizing radiations  

International Nuclear Information System (INIS)

Ignoring the numerous, known and mainly unknown, interactions between chemicals and ionizing radiations, causes strong controversy about the risks of ionizing radiations. Yet the best known interactions between chemicals and radiations is that between radon and tobacco smoke. Although it is and it will be always impossible to derive quite quantitative laws for this interaction, it has been possible to derive some semi-quantitative relationships based on reasonable assumptions and statistics on lung cancer deaths in developed countries. They show that ignoring the dangers of tobacco smoking as we did still long after we had recognised the dangers of radiations, could asses to radiations thirty or forty times more risks than reality. As present world is flown by tens of thousands chemicals, little or not present in a natural environment, and as it would be very surprising that some ...

162

Environmental impact assessment around TRIGA research reactor  

International Nuclear Information System (INIS)

Population distribution, atmospheric change, X/Q, characteristics of terrestrial ecosystem around Seoul site were surveyed. Environmental radiation and radioactivities such as gross#alpha#, gross#beta#, Cs-137, Sr-90 and H-3 of various environmental samples were analyzed. The values of environmental radiation dose tended to increase gradually in the light of the recent five years' results of environmental radiation monitoring around the nuclear power plants from 1980 to 1984, however, the changes were not significant. In addition, continuous assessment of environmental radiation monitoring on the roofs of main building and life science building at KAERI showed that the environmental radiation dose tended to increase a little during the night time. Judging from the above results, it is concluded that environmental contamination level by radioactive materials ...

1985-04-01

163

Staging of multiple myeloma with MRI: comparison to MSCT and conventional radiography; Staging des multiplen Myeloms mit der MRT: Vergleich zur MSCT und zur konventionellen Roentgendiagnostik  

Energy Technology Data Exchange (ETDEWEB)

The staging of patients with multiple myeloma demands sensitive imaging methods for the assessment of the skeletal system. MRI allows for direct visualization of the bone marrow which exhibits five different infiltration patterns in multiple myeloma: 1. normal appearance of the bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. ''salt and pepper'' pattern with inhomogeneous bone marrow signals due to multiple fat islands. The combination of T1w-SE and STIR sequences is best suited for detecting all infiltration patterns and for the differential diagnoses e. g. hemangiomas. With parallel imaging in MRI, acquisition times can be markedly reduced and whole-body screening of the bone marrow can be achieved within 30 min. MRI is superior to radiography for the detection of focal as well as diffuse infiltration. Multidetector computed tomography and especially 16- and ...

2004-09-01

164

Efficiency of a lead-containing tie for radiation protection of the thyroid gland  

Energy Technology Data Exchange (ETDEWEB)

During fluoroscopy the examiner is usually protected by a radiation-reducing body shield, leaving the thyroid unprotected. The fact that the thyroid is located in a region of the neck usually covered by the shirt collar led to the idea of designing a tie with lead core, providing easy and ''decorative'' reduction of the radiation dose. Sonographic examinations were carried out in 20 volunteers (10 men, 10 women) to determine the size of the gland and its coverage by such a tie. The reduction of the surface and organ dose was assessed using film dosimetry with scattered radiation, the body of the examiner being simulated by an Alderson phantom. On average 88% of the thyroid gland surface area was covered. Surface dose was reduced to 1%, and organ dose to 10% of the value without the protection tie. (Author).

1992-11-01

165

Efficiency of a lead-containing tie for radiation protection of the thyroid gland  

International Nuclear Information System (INIS)

During fluoroscopy the examiner is usually protected by a radiation-reducing body shield, leaving the thyroid unprotected. The fact that the thyroid is located in a region of the neck usually covered by the shirt collar led to the idea of designing a tie with lead core, providing easy and ''decorative'' reduction of the radiation dose. Sonographic examinations were carried out in 20 volunteers (10 men, 10 women) to determine the size of the gland and its coverage by such a tie. The reduction of the surface and organ dose was assessed using film dosimetry with scattered radiation, the body of the examiner being simulated by an Alderson phantom. On average 88% of the thyroid gland surface area was covered. Surface dose was reduced to 1%, and organ dose to 10% of the value without the protection tie. (Author).

166

Chernobyl accident: the crisis of the international radiation community  

Energy Technology Data Exchange (ETDEWEB)

The information given in the present report about the Chernobyl accident and its radiological consequences indicates a serious crisis of the international radiation community. The following signs of this crises can be discerned: The international radiation community did not recognize the real reasons of the accident for a long time. It could not make a correct assessment of the damage to the thyroid of the affected populations of Belarus, Russia and the Ukraine. Up to present time it rejects the reliable data on hereditary malformations. It is not able to accept reliable data on the increase in the incidence in all categories of people affected by the Chernobyl accident. The international radiation community supported the Soviet authorities in their attempts to play down the radiological consequences of the Chernobyl accident for a long time. (author)

1998-03-01

167

Modulation of the intestinal response to ionizing radiation by anticoagulant and non-anticoagulant heparins.  

Science.gov (United States)

Endothelial dysfunction is involved in radiation responses in many normal tissues, including intestine. Endothelium-directed interventions ameliorate intestinal radiation injury (radiation enteropathy) in animal models, and anecdotal reports also suggest a beneficial effect of heparin. This study assessed low molecular weight heparin as an intestinal radiation response modifier. Rats underwent localized small bowel irradiation. Groups of rats were treated with saline, nadroparin (3 mg/kg/d), or a non-anticoagulant heparin (SR80258, 3 mg/kg/d), from 3 days before to 2 weeks after irradiation. The intestinal radiation response was assessed 2 weeks and 6 weeks after irradiation using quantitative histology; morphometry, and cellular and molecular end-points. Compared to vehicle-treated controls, nadroparin significantly exacerbated structural ...

2005-11-01

168

Large intracranial vessel occlusive vasculopathy after radiation therapy in children: clinical features and usefulness of magnetic resonance imaging  

International Nuclear Information System (INIS)

Purpose: To assess the relationship between large intracranial vessel occlusive vasculopathy (vasculopathy) and radiation therapy, and to clarify the clinical efficacy of magnetic resonance (MR) imaging in the diagnosis and screening of the vasculopathy. Methods and Materials: We retrospectively evaluated the medical records and serial MR images for 32 pediatric patients, in whom radiation therapy had been given to fields including the circle of Willis and major cerebral arteries. All children had periodically undergone follow-up neurologic assessment and MR imaging examinations at Kanagawa Children's Medical Center for more than one year after radiation therapy (range 1.3-14 years). Patients who had not remained free of tumor progression up to the time of final evaluation were excluded. Results: Vasculopathy developed in 6 of 32 patients 2-13 years after ...

1997-05-01

169

Effective per-capita dose as a yardstick for medical radiation exposure of the population - a supplement or an alternative to the genetically significant dose  

International Nuclear Information System (INIS)

The genetically significant dose (GSD) is an index variable which exclusively allows to describe the genetic risk in the progeny of a population due to the application of ionizing radiation and radioactive substances in one part of this population. It may result in wrong interpretation of population exposure at increasing incidence of examinations in a population involving ionizing radiation and radioactive drugs at simultaneously increasing application of alternative methods in children and adolescents owing to the fact that it indicates a downward trend although somatic exposure of this population has increased. Therefore, it is recommended to state both the GSD and the level of somatic radiation exposure of the population taken from the individual sources for the comparison and assessment of radiation exposure from various sources in future. Although the somatically significant ...

1984-06-01

170

Biological effects after prenatal irradiation (embryo and fetus) ICRP Publication 90 Approved by the Commission in October 2002  

International Nuclear Information System (INIS)

In its 1990 recommendations, the ICRP considered the radiation risks after exposure during prenatal development. This report is a critical review of new experimental animal data on biological effects and evaluations of human studies after prenatal radiation published since the 1990 recommendations. Thus, the report discusses the effects after radiation exposure during pre-implantation, organogenesis, and fetogenesis. The aetiology of long-term effects on brain development is discussed, as well as evidence from studies in man on the effects of in-utero radiation exposure on neurological and mental processes. Animal studies of carcinogenic risk from in-utero radiation and the epidemiology of childhood cancer are discussed, and the carcinogenic risk to man from in-utero radiation is assessed. Open questions and needs for future research are ...

171

Status of the WAND (Waste Assay for Nonradioactive Disposal) project as of July 1997  

Energy Technology Data Exchange (ETDEWEB)

The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform the data analysis. WAND system minimum ...

1998-03-01

172

Assessment of the role of oxygen and mitochondria in heat shock induction of radiation and thermal resistance in Saccharomyces cerevisiae  

Energy Technology Data Exchange (ETDEWEB)

In response to a heat shock, the yeast Saccharomyces cerevisiae undergoes a large increase in its resistance to heat and, by the induction of its recombinational DNA repair capacity, a corresponding increase in resistance to radiation. Yeast which lack mitochondrial DNA, mitochondria-controlled protein synthetic apparatus, aerobic respiration, and electron transport (rho/sup 0/ strain) were used to assess the role of O/sub 2/, mitochondria, and oxidative processes controlled by mitochondria in the induction of these resistances. We have found that rho/sup 0/ yeast grown and heat shocked in either the presence or absence of O/sub 2/ are capable of developing both radiation and heat resistance. We conclude that neither the stress signal nor its cellular consequences of induced heat and radiation resistance are directly dependent on O/sub 2/, mitochondrial DNA, or mitochondria-controlled protein synthetic ...

1983-10-01

173

TLD array for precise dose measurements in stereotactic radiation techniques  

International Nuclear Information System (INIS)

We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and calculated data at full width at half maximum. ...

1996-12-01

174

Measurements of K-shell x-ray production cross sections and K to L and M-shell radiative vacancy transfer probabilities for Nd, Eu, Gd, Dy and Ho at excitation with 59.5 keV photons in an external magnetic field  

International Nuclear Information System (INIS)

The effect of the #+-# 0.75 T external magnetic field on the K_#alpha#_1, K_#alpha#_2, K_#beta#_'_1 and K_#beta#_'_2 x-ray production cross sections and radiative vacancy transfer probabilities from K-shell to L2 and L3 subshells and M-shell for ferromagnetic Nd, Gd and Dy and paramagnetic Eu and Ho have been investigated, using the 59.5 keV incident photons. K-shell fluorescence yields and K x-ray intensity ratios for these elements have been determined in the external magnetic field also. The K x-rays from different targets were detected using a high-resolution Si(Li) semiconductor detector. For B = 0, the present experimental results were compared with the experimental and theoretical data in the literature. The results show that K-shell fluorescence parameters such as photoionization cross section, fluorescence yield, radiation rates, vacancy transfer probabilities and spectral linewidth can change owing to the applied ...

2006-06-19

175

Oncogenic transformation produced by agents and modalities used in cancer therapy and its modulation  

International Nuclear Information System (INIS)

The long-term survival of certain patients after treatment with radiation or chemotherapeutic agents has allowed the realization that agents that effectively control cancer in the human subject may also possess an oncogenic potential, resulting in secondary malignancies in a significant proportion of surviving patients. A quantitative assessment of the oncogenic effects of these agents at a cellular level is important, as is information on conditions and agents that may effectively alter the development of the neoplastic state. Cell culture systems where the neoplastic transformation of cells can be scored after exposure to carcinogens offer powerful tools for evaluating the oncogenic potential of radiation and chemotherapeutic agents.

1982-01-01

176

Health effects[1997 Scientific Report of the Belgian Nuclear Research Centre  

Energy Technology Data Exchange (ETDEWEB)

The objectives of the research in the field of epidemiology , performed at the Belgian Nuclear Research Centre SCK-CEN are (1) to study cancer mortality and morbidity in nuclear workers in Belgium; (2) to document the feasibility of retrospective cohort studies in Belgium; (3) to participate in the IARC study. For radiobiology, the main objectives are: (1) to elucidate the mechanisms of the effects of ionizing radiation on the mammalian embryo during the early phase of its development, (2) to assess the genetic risks of maternal exposure to ionizing radiation, (3) to elucidate the mechanisms by which damage to the brain and mental retardation are caused in man after prenatal irradiation. The main achievements in these domains for 1997 are presented.

1998-07-01

177

A marine compartment model for collective dose assessment of liquid radioactive effluents  

International Nuclear Information System (INIS)

A compartment model is described which is currently used by the Ministry of Agriculture, Fisheries and Food to calculate collective radiation exposure due to liquid radioactive wastes discharged to sea from UK nuclear sites. Collective dose is a useful indicator of the radiological impact of a disposal practice and is one of the quantities needed to show compliance with the ICRP system of dose limitation. The model has been used for the purposes of the Sizewell Inquiry to predict the collective radiation exposure from reactor operation at Sizewell and, on the basis of current Sellafield experience, correlations between dose and discharge for disposals of fuel reprocessing wastes. (author).

1982-01-01

178

Estimation of armature condition in concrete with gamma-absorption method  

International Nuclear Information System (INIS)

Bases of the algorithm for assessing the reinforcement status in reinforced concrete products by gamma-absorption method are presented. Analytical equations are obtained for estimation of error of the parameter characterizing the degree of reinforcement destruction. It is recommended to use high-energy Bremsstrahlung sources-betatrons of 4-10 MeV maximum energy for testing products of 500-600 mm thick. Linear radiation attenuation factor (LAF) of concrete in estimated equation is replaced by effective LAF of concrete, and LAF of reinforcement and corrosion materials - by differential LAF. Corresponding LAF of nonevident form in the algorithm is assessed by the results of processing of direct-shadow radiographs of defectometers

179

Assessing radiologic risk for population due to human activities  

International Nuclear Information System (INIS)

The most important factor in assessing radiologic risk is ensuring scientific means for evaluation of the radioactive release impact upon humans and organisms. To evaluate quantitatively this impact not only knowledge of radioactivity distribution in these dynamical systems is necessary but also understanding the transfer mechanisms between ecosystem components is needed. Thus a complete radioecologic study appear to be very complex and needs defining the source term, dynamic description of radionuclides behavior in the ecosystem, estimation of radiation doses in the major components of the ecosystem and finally the effects of radiation doses upon different parts of the systems. A diagram of the steps implied in evaluation of the effects due to radioactive effluent release in the environment is presented and discussed. The following steps are described: - identification of radioactive sources, as well as their input rate. ...

2002-09-06

180

Results of radon concentration measurements in some regions of Russia  

Energy Technology Data Exchange (ETDEWEB)

Inhalation of radon and its daughter products makes the major contribution to the total exposure of the population to natural radiations. In implementing a complex ecological survey, concentrations of radon and its daughter products were measured in different regions of Russia, namely, in the St. Petersburg Region, the Central Territories and the Altay Territory. Two suitable low price versions of the dosemeters for measuring environmental radon concentrations based on track-etch and activated-charcoal detectors were used. The radon daughter product activity and the effective dose equivalents were calculated with an equilibrium factor of 0.5 and a recommended effective dose equivalent factor of 0.061 mSv (Bq m{sup -3}){sup -1}. Indoor measurements were taken in more than 1000 dwellings and public and industrial buildings of 21 towns and villages. The track chambers were exposed for about 2-3 months and the charcoal ...

1996-01-01

181

Results of radon concentration measurements in some regions of Russia  

International Nuclear Information System (INIS)

Inhalation of radon and its daughter products makes the major contribution to the total exposure of the population to natural radiations. In implementing a complex ecological survey, concentrations of radon and its daughter products were measured in different regions of Russia, namely, in the St. Petersburg Region, the Central Territories and the Altay Territory. Two suitable low price versions of the dosemeters for measuring environmental radon concentrations based on track-etch and activated-charcoal detectors were used. The radon daughter product activity and the effective dose equivalents were calculated with an equilibrium factor of 0.5 and a recommended effective dose equivalent factor of 0.061 mSv (Bq m"-"3)"-"1. Indoor measurements were taken in more than 1000 dwellings and public and industrial buildings of 21 towns and villages. The track chambers were exposed for about 2-3 months and the charcoal detectors for ...

182

Improvement of a high-resolution pulse cold neutron spectrometer AGNES  

International Nuclear Information System (INIS)

AGNES is a chopper spectrometer installed at the top of the C3 cold guide of JRR-3 (JAERI, Tokai). In 2004 - 2006, this spectrometer was greatly improved by installing (1) 208 new detectors to make the detector bank complete, (2) new radiation shields composed of Fe (14 mm), polyethylene (50 mm), B4C rubber (10 mm), and Cd (0.5 mm) sheets, (3) a new control system for the anti-frame-overlap chopper rotating simultaneously with the Fermi chopper, (4) a monitor counter at the space between the chopper and monochromator, (5) a neutron guide tube (50 cm) before the monochromator, (6) a new instrument control (monochromators, choppers, beam narrowers, etc.) and measurement control (real-time data monitoring, sample temperature control, etc.) systems, (7) a top-loading type cryostat workable at a wide temperature range of 6 - 480 K. As the results of these improvements, the signal intensity has been increased by 3.3 and the ...

2007-01-01

183

Correction for loss of track density due to overlapping track on SSNTD  

Energy Technology Data Exchange (ETDEWEB)

Solid state nuclear track detectors (SSNTD) record radiation in the form of tracks. In the case of high track density, however, it is not always possible to distinguish each track separately. The track density might then be underestimated unless the loss of track number due to overlapping is compensated. An elaborated 'erosion' or curve fitting process is applied usually, for the separation of the overlapping tracks, to automatic track counting systems. This paper shows a much simpler correction method which was developed by the analogy of the correction equation for the dead time of GM counters. From a set of about 10 data obtained from high track density detectors, the equation for SSNTD can be determined by a least square fitting. Once the equation is found, true track density could be derived easily without any help of complex image processing or calculation, such as the erosion or curve fitting. This ...

1990-06-01

184

Assessment of the effects of pixel loss on image quality in direct digital radiography  

Energy Technology Data Exchange (ETDEWEB)

Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. Measurement of the MTF, ...

2004-03-21

185

Assessment of the effects of pixel loss on image quality in direct digital radiography  

International Nuclear Information System (INIS)

Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. Measurement of the MTF, NPS and DQE can reveal small changes ...

2004-03-21

186
191

Reconnaissance radiological characterization for the White Point Nike Missile Site, San Pedro, California  

International Nuclear Information System (INIS)

This report is the result of field work performed at the former White Point Nike Missile Site, San Pedro, California. The Hazardous Waste Remedial Actions Program tasked the Oak Ridge National Laboratory Pollutant Assessments Group in Grand Junction, Colo., with this project. The objective was to determine whether or not radioisotopes possibly associated with past Department of Defense (DOD) operations were present and within accepted background levels. The radiation survey was accomplished by performing three independent radiation surveys, both outdoors and indoors, and random soil sampling. Initially, the site was land surveyed to develop a grid block system. A background radiation investigation was performed out in the San Pedro area.

192

Health effects  

International Nuclear Information System (INIS)

The main objectives of research in the field of health effects at the Belgian Nuclear Research Centre SCK-CEN are: (1) to study cancer mortality and morbidity in nuclear workers in Belgium; (2) to document the feasibility of retrospective cohort studies in Belgium; (3) to participate in the IARC study; (4) to elucidate the mechanisms of the effects of ionizing radiation on the mammalian embryo during the early phases of its development; (5) to assess the genetic risks of material exposure to ionizing radiation; (6) to elucidate the cellular mechanisms leading to brain damage after prenatal irradiation; (7) to advise authorities and to provide the general population with adequate information concerning the health risk arising from radiation exposure. Progress and major achievements in these topical areas for 1997 are reported.

193

Abstracts of 5. International conference 'Nuclear and Radiation Physics'  

International Nuclear Information System (INIS)

The 5-th International conference 'Nuclear and Radiation Physics' was held in Almaty (Kazakhstan) 26-29 September 2005. Besides basic problems of nuclear and solid state physics the conference paid considerable attention to applied topics important for industry and science in Kazakhstan; they include fuel and construction materials for nuclear power production, new technologies and materials for their production, materials for hydrogen power production, handling and utilization of radioactive waste, analytical methods for combating with illicit trafficking of nuclear and radioactive materials, technologies for reduction and assessment of environmental risk from radiation-hazardous materials and sites, production and application of isotopes, application of nuclear technologies in medicine and industry. On the conference more than 300 papers were presented by participants from 20 countries.

2005-09-26

194

Preliminary performance assessment for the Waste Isolation Pilot Plant, December 1992. Volume 1, Third comparison with 40 CFR 191, Subpart B  

Energy Technology Data Exchange (ETDEWEB)

Before disposing of transuranic radioactive wastes in the Waste Isolation Pilot Plant (WIPP), the United States Department of Energy (DOE) must evaluate compliance with applicable long-term regulations of the United States Environmental Protection Agency (EPA). Sandia National Laboratories is conducting iterative performance assessments of the WIPP for the DOE to provide interim guidance while preparing for final compliance evaluations. This volume contains an overview of WIPP performance assessment and a preliminary comparison with the long-term requirements of the Environmental Radiation Protection Standards for Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive Wastes (40 CFR 191, Subpart B).

1992-12-01

195

Green Tea Extract (Epigallocatechin-3-Gallate) Reduces Efficacy of Radiotherapy on Prostate Cancer Cells  

British Library Electronic Table of Contents (United Kingdom)

ObjectivesTo assess the influence of epigallocatechin-3-gallate (EGCG) on the efficacy of ionizing radiation on prostate cancer cells because of the increased use of dietary interventions, especially by patients with prostate cancer. Radiotherapy is used to treat localized prostate cancer. Some people consume green tea (EGCG) as a chemopreventive agent against prostate cancer. Green tea can act as an antioxidant and induce superoxide dismutase enzymes, which could scavenge the free oxygen radicals generated by radiotherapy. MethodsProstate cancer cell line DU145 cells were treated with EGCG or radiotherapy, or both. Cell death was assessed using trypan blue cell counting, and apoptosis was confirmed by assessing poly (adenosine phosphate ribose) polymerase cleavage. The antioxidant potenti...

2011-01-01

196

Small world when building a particle detector prototype, the devil is in the tiny details  

CERN Multimedia

Small world when building a particle detector prototype, the devil is in the tiny details

2004-01-01

197

Photodiode Scintillation Detector for Anti-Coincidence Shielding  

Science.gov (United States)

Photodiode Scintillation Detector for Anticoincidence Shielding An important goal of space research is to understand the physics involved in the activity of ...

198

Radiological assessment of terrestrial environment of facilities of G.I.P. CYCERON from Caen - year 2003; Bilan radiologique de l'environnement terrestre des installations du GIP CYCERON de Caen - annee 2003  

Energy Technology Data Exchange (ETDEWEB)

Concerning the gamma emitters, the only analysis on soils put in evidence the presence of cesium-137 ({sup 137}Cs), that does not come from the cyclotron functioning but from past man action as the Chernobylsk accident and the nuclear weapon tests in atmosphere. Independently of the functioning of the installation, we observe an increase of the ambient gamma radiation only near radioactive waste storage. It results of the storage of the former cyclotron elements. The induced increase is moderated because at 5 meters the values do not exceed the background noise. In relation with the functioning of the installation an increase of the ambient gamma radiation is noticed. Two causes are to considered: the release of radionuclides in atmosphere with gaseous effluents and the radiance of radiation sources inside the building. After the stopping of the installation (48 h at least), no increase of gamma ...

2004-07-01

199

Preoperative assessment of hilar cholangiocarcinoma using multidetector-row CT. Correlation with histopathological findings  

International Nuclear Information System (INIS)

Our aim was to investigate the diagnostic reliability of multidetector-row computed tomography (MDCT) for preoperative assessment of local tumoral spread in hilar cholangiocarcinoma. Thirteen of 30 consecutive patients with hilar cholangiocarcinoma who underwent surgery, excluding 17 patients who underwent biliary drainage or preoperative portal embolization, were retrospectively evaluated. Using MDCT systems of 4 detector rows or 16 detector rows, plain and dynamic contrast-enhanced images of three phases were obtained. Extent of tumor spread and lymph node metastasis were assessed with MDCT and compared with histopathological findings. The Bismuth-Corlette classification of hilar cholangiocarcinoma with MDCT were type I, 1 patient; type IIIa, 3 patients; type IIIb, 4 patients; and type IV, 5 patients; those with histopathological findings were type I, 1 patient; type IIIa, 2 patients; type IIIb, 4 ...

2008-08-01

200

Assessment of the impact of the greenhouse gas emission and sink scenarios in Finland on radiative forcing and greenhouse effect  

Energy Technology Data Exchange (ETDEWEB)

The objective of this work is to study greenhouse gas emissions and sinks and their greenhouse impact as a function of time. The greenhouse impact is expressed in terms of global average radiative forcing, which measures the perturbation in the Earth`s radiation budget. Radiative forcing is calculated on the basis of the concentration changes of the greenhouse gases and the radiation absorption properties of the gases. It takes into account the relatively slow changes in the concentrations due to natural removal and transformation processes and also allows a comparison of the impact of various greenhouse gases and their possible control options as a function of time. In addition to the applications mentioned above, the anthropogenic greenhouse gas emission histories of Nordic countries have been estimated, and the radiative forcing caused by them has been calculated with REFUGE. The ...

1996-12-31

201

The malignancy significant dose from external beam radiotherapy  

International Nuclear Information System (INIS)

In the present study an estimate is made of the malignancy significant dose from external beam radiotherapy in New Zealand utilizing data obtained in a survey conducted in 1975. This survey had been designed to assess genetically significant dose. A weighted effective dose equivalent is derived from the malignancy significant dose for direct comparison with mean per capita effective dose equivalents arising from other sources of radiation. 14 refs., 1 fig., 8 tabs.

1987-01-01

202

Radiation Dosimetry considerations in the safe administration of therapeutic radiopharmaceuticals  

Energy Technology Data Exchange (ETDEWEB)

A set of eight questions was put to advanced nuclear medicine physicians-in-training participating in a continuing assessment exercise in practical therapeutic nuclear oncology. Using the particular example of {sup 131}I-MIBG treatment of neuroblastoma in children, the questions were directed to the rationale of therapy and the contribution of other forms of treatment to toxic effects. The best answer to the questions are reproduced together with an introduction by the examiner, Dr. H. Turner. tabs.

1995-12-01

203

Non-Linear Dose-Response Relationships in Biology, Toxicology and Medicine - An International Conference  

Energy Technology Data Exchange (ETDEWEB)

Conference abstract book contains seven sections: Plenary-4 abstracts; Chemical-9 abstracts; Radiation-7 abstracts; Ultra Low Doses and Medicine-6 abstracts; Biomedical-11 abstracts; Risk Assessment-5 abstracts and Poster Sessions-25 abstracts. Each abstract was provided by the author/presenter participating in the conference.

2002-05-28

204

Genetic and somatic risks in X-ray diagnosis  

International Nuclear Information System (INIS)

Based on a literature study an actual summary of the risk-utility problems in X-ray diagnosis is outlined due to the Recommendations of the International Commission for Radiation Protection (ICRP publication 26/1977). Papers demonstrating quantitative assessment of the somatic and genetical risk in X-ray examination are preferably cited and evaluated. It is concluded that the somatic and genetical risk is low in diagnostic ratiology. However, it must not be neglected and has always to be compared to the utility of an examination as well as to other risks of the examination. (author).

1982-01-01

205

Development of fire simulation models for radiative heat transfer and probabilistic risk assessment  

Energy Technology Data Exchange (ETDEWEB)

An essential part of fire risk assessment is the analysis of fire hazards and fire propagation. In this work, models and tools for two different aspects of numerical fire simulation have been developed. The primary objectives have been firstly to investigate the possibility of exploiting state-of-the-art fire models within probabilistic fire risk assessments and secondly to develop a computationally efficient solver of thermal radiation for the Fire Dynamics Simulator (FDS) code. In the first part of the work, an engineering tool for probabilistic fire risk assessment has been developed. The tool can be used to perform Monte Carlo simulations of fires and is called the Probabilistic Fire Simulator (PFS). In Monte Carlo simulation, the simulations are repeated multiple times, covering the whole range of variability of the input parameters and thus resulting in a distribution of results covering what can ...

2008-07-01

206

The PAMELA space experiment: first year of operation  

Energy Technology Data Exchange (ETDEWEB)

On the 15th of June 2006 the PAMELA experiment, mounted on the Resurs DK1 satellite, was launched from the Baikonur cosmodrome and it has been collecting data since July 2006. PAMELA is a satellite-borne apparatus designed to study charged particles in the cosmic radiation, to investigate the nature of dark matter, measuring the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved, and to search for antinuclei with unprecedented sensitivity. The apparatus comprises a time-of-flight system, a silicon-microstrip magnetic spectrometer, a silicon-tungsten electromagnetic calorimeter, an anticoincidence system, a shower tail catcher scintillator and a neutron detector. The combination of these devices allows charged particle identification over a wide energy range.

2008-05-15

207

Seasonal variation measurements of radon levels in caves using SSNTD method  

Energy Technology Data Exchange (ETDEWEB)

The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm{sup -3}, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.

2008-08-15

208

Seasonal variation measurements of radon levels in caves using SSNTD method  

International Nuclear Information System (INIS)

The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm-3, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.

2008-08-01

209

Real time neutron radioscopy - trends and applications  

International Nuclear Information System (INIS)

Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor

2003-11-12

210

Neutron resonances in "1"0"0Mo and valence neutron capture  

International Nuclear Information System (INIS)

Neutron resonance interactions with "1"0"0Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% "1"0"0Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture #gamma#-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.

211

Multielement analysis of air samples. Determination of iron, zinc, lead, and bromine content by the radionuclide X-ray fluorescence analysis  

Energy Technology Data Exchange (ETDEWEB)

Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A /sup 238/Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed.

1981-01-01

212

Method for determining hydrogen mobility as a function of temperature in superconducting niobium cavities  

Energy Technology Data Exchange (ETDEWEB)

A method for determining the mobility of hydrogen as a function of temperature in superconducting niobium cavities comprising: 1) heating a cavity under test to remove free hydrogen; 2) introducing hydrogen-3 gas into the cavity; 3) cooling the cavity to allow absorption of hydrogen-3; and 4) measuring the amount of hydrogen-3 by: a) cooling the cavity to about 4.degree. K while flowing a known and regulated amount of inert carrier gas such as argon or helium into the cavity; b) allowing the cavity to warm at a stable rate from 4.degree. K to room temperature as it leaves the chamber; and c) directing the exit gas to an ion chamber radiation detector.

2008-03-11

213

Measurement of cumulative and independent yields of fission products from thermal-neutron fission of /sup 242//sup m/ Am  

Energy Technology Data Exchange (ETDEWEB)

The mass and charge distributions in an unseparated mix of fission product nuclei from thermal-neutron fission of /sup 242m/Am were studied through semiconductor gamma-ray spectrometry. Samples of the fissionable material under study were irradiated in a vertical irradiation tube of the MIFI IRT research reactor. Following irradiation, measurements were made on aperture-calibrated semiconductor detectors. For broader identification of fission fragment nuclides three experiments were conducted that differed substantially in irradiation duration. The spectrum of gamma radiation from the mix of fission products and the time dependences of count rate at total absorption peaks were analyzed on SM-4 and Iskra-226 computers. The values of yields obtained were compared with data of investigations conducted earlier with other experimental methods, and also with the results of calculations.

1985-03-01

214

Instruments for X-ray fluorescence analysis and spectrometry  

International Nuclear Information System (INIS)

The radionuclide X-ray fluorescence analyzer consists of a source changer and a sample changer. "5"5Fe, "1"0"9Cd and "2"4"1Am are used as excitation sources. The radiation is detected with a semiconductor Si(Li) detector. The complete assembly of the apparatus consists of an imagine unit, a keyboard, a floppy disc drive, a printer, a console and a rack with analog and digital electronics. Its multichannel amplitude analyzer consists of power supplies, a high voltage supply, a linear amplifier, an analog-to-digital converter and a computer. The technical specifications are given. The control and data processing system is controlled with an MHB 8080A microprocessor. Software for semiconductor gamma spectrometry and for quantitative gamma spectrometry will be supplied with the equipment. (E.S.). 3 figs., 4 refs.

215

Furnace for rapid change of temperature for neutron diffraction  

International Nuclear Information System (INIS)

A new furnace for neutron diffraction experiments is capable of heating and cooling a sample very rapidly. The rapid heating is done by two circular infrared lamps placed over and under a sample, whose radiation is roughly focused on the sample by a reflector. The rapid cooling is done by high-pressure gas blows against the sample from two circular nozzles which are also placed over and under the sample. This system enables us to obtain the heating rate of over 1000"0C/min and cooling rate of -500"0C/min for an alloy of 10 mm diameter and 30 mm length. The performance is sufficient to carry out some kinetics measurements in real-time neutron diffraction by the use of a position-sensitive detector. This kind of experiment is demonstrated by the observation of the relaxation process of order--disorder transitions in CuZn and Ni_3Mn alloys.

216

Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr  

Energy Technology Data Exchange (ETDEWEB)

Neutron capture ..gamma..-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.

1985-01-15

217

Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr  

International Nuclear Information System (INIS)

Neutron capture #gamma#-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.

1984-09-10

218

Diffusion examined by diffraction  

Science.gov (United States)

X-ray diffraction offers a unique combination of advantages for kinetic study which include the non-destructive nature of the measurement, the use of bulk crystals, and the convenience of the experimental arrangements. These attributes and the availability of position-sensitive detectors and high-flux synchrotron radiation sources make this technique most useful for in situ, dynamical investigations. When using diffraction techniques to determine a diffusion coefficient, the principle of analysis entails a scattering theory and a kinetic model. The former allows the kinetic parameter(s) to be extracted from measured intensity, while the latter relates the kinetic parameter(s) to the diffusion coefficient(s). Three examples are demonstrated: (1) Palladium Silicide (Pd{sub 2}Si) Layer Growth on Silicon, (2) Decomposition of an Ni-12.5at%Si Superalloy, and (3) Short-range Ordering in Cu-Au Solid Solutions.

219

Concentrations of radon and decay products in various underground mines in western Turkey and total effective dose equivalents  

Energy Technology Data Exchange (ETDEWEB)

Radon concentration measurements were performed for one year in 12 different boron, chromium and coal underground mines in Western Turkey. Lucas cells and nuclear track detectors were used for the measurements of radon and its decay products. The effects of parameters, such as type of mine, gallery depth and ventilation rate, on the radon concentration in mine air were examined. The radiation exposure doses of miners due to the inhalation of radon and radon daughters were determined. Gamma survey measurements were also realized together with radon measurements and the total effective dose equivalents in mSv y{sup -1} were estimated.

1998-01-01

220

A mobile gamma scanning system for detecting radiation anomalies  

Energy Technology Data Exchange (ETDEWEB)

A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A /sup 226/Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.

1983-09-01

221

A mobile gamma scanning system for detecting radiation anomalies  

International Nuclear Information System (INIS)

A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A "2"2"6Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.

222

Useful vacancies: Positron beam interrogation of fluorine-vacancy complexes in semiconductor device structures  

Energy Technology Data Exchange (ETDEWEB)

The formation, migration and agglomeration in silicon of fluorine-vacancy complexes have been monitored by single-detector Doppler broadening spectroscopy. After electronics engineers found that fluorine ion implantation effectively eliminated the transient-enhanced diffusion of dopants in the creation of ultra-shallow junctions, a vital step in the further miniaturization of device structures, positron beams have played a pivotal role in providing an insight into the mechanisms underlying this phenomenon, being able to detect FV complexes in implanted and annealed samples. Secondary Ion Mass Spectrometry has provided complementary information on fluorine concentrations so that the nature of the F{sub m}V{sub n} complexes can be further assessed. New results on Si and SiGe structures are presented.

2008-10-31

223

Radiation epidemiological analysis of late effects of population exposure at northern part of east ural radioactive trace  

Energy Technology Data Exchange (ETDEWEB)

Population residing in the northern part of the Chelyabinsk oblast and the south eastern part of the Sverdlovsk oblast of Russia affected to accidental exposure since 1957. The territory (East Ural Radioactive Trace - EURT) was contaminated after explosion of container with highly radioactive wastes at the Mayak Production Association. Studies of health effects of exposure in the southern, head part of EURT are conducted in the Ural Research and Practical Center of Radiation Medicine (U.R.P.R.M.). In the 1990's U.R.P.C.R.M. formed a cohort of EURT within Chelyabinsk oblast (14,500 cases and 19,400 external controls). The cohort was followed in 1957-1987 and the results of the study are discussed by Crestinina et al. First results of study on exposure late health effects among rural population in the northern part of the EURT are presented in this paper. Firstly, or the period 1958-2000 a statistically significant increase in cancer mortality associated ...

2006-07-01

224

Visibility of tumor-like details in inline phase contrast mammography using quasimonochromatic X-ray sources  

Energy Technology Data Exchange (ETDEWEB)

A new generation of quasimonochromatic high-flux X-ray sources, based on the X-ray radiation produced through Compton scattering between an electron beam and a laser beam, is under development. One of the possible applications of this source is inline phase contrast mammography, based on the observation of the edge-enhancement effect that can be observed at the border of structures inside the breast in images produced using a partially or totally coherent X-ray beam. In this work we present the results of a set of simulations of inline phase contrast mammography using typical inverse Compton scattering sources parameters. The simulated sample was a tumour-like mass having spherical shape, diameter between 200 {mu}m and 5 mm, placed inside a breast-like matrix, 4 cm thick, and a standard composition of 50% glandular tissue and 50% adipose tissue. We discuss the minimum requirements for mammography using inverse Compton scattering sources and we discuss how the ...

2009-09-01

225

Measuring instrument for radiometric monitoring of solids and heavy metals in water  

International Nuclear Information System (INIS)

A combination of measuring instruments, consisting of a Beta-Sedimeter and a radionuclide X-ray fluorescence instrument, is described. With the Beta-Sedimeter the C-14-radiation is measured. Through direct irradiation with photons of a Pu238-source in an ancillary irradiation chamber and energy dispersing measurement of the K- and L-radiation resp. of the excited heavy metals with the aid of a Si(Li)-semiconductor detector and a 4-channel analyzer the heavy metal concentrations of the heavy metals Zn, Cr, Ni and Pb are determined. For the determination of cadmium the indirect excitation with Am-241 and Dy-targets is described. The system produces records and operates fully automatically in a step-by-step mode with a testing cycle of 45 minutes. In connection with the process monitoring of the wastewater from a zinc plating plant during a period of 8 months the concentration of the solid material and of the metals Cr and Zn, ...

1979-01-01

226

Measurement of L X-ray fluorescence cross-sections for elements with 45 Z50 using synchrotron radiation at 8keV  

British Library Electronic Table of Contents (United Kingdom)

The L shell fluorescence cross-sections of the elements in range 45Z50 have been determined at 8keV using Synchrotron radiation. The individual L X-ray photons, Ll, La, LbI, LbII, LgI and LgII produced in the target were measured with high resolution Si(Li) detector. The experimental set-up provided a low background by using linearly polarized monoenergetic photon beam, improving the signal-to-noise ratio. The experimental cross-sections obtained in this work were compared with available experimental data from Scofield [1,2] Krause [3,4] and Scofield and Puri et al. [5,6]. These experimental values closely agree with the theoretical values calculated using Scofield and Krause data, except for the case of Lg, where values measured of this work are slighter higher.

2011-01-01

227

High order statistical signatures from source-driven measurements of subcritical fissile systems  

Energy Technology Data Exchange (ETDEWEB)

This research focuses on the development and application of high order statistical analyses applied to measurements performed with subcritical fissile systems driven by an introduced neutron source. The signatures presented are derived from counting statistics of the introduced source and radiation detectors that observe the response of the fissile system. It is demonstrated that successively higher order counting statistics possess progressively higher sensitivity to reactivity. Consequently, these signatures are more sensitive to changes in the composition, fissile mass, and configuration of the fissile assembly. Furthermore, it is shown that these techniques are capable of distinguishing the response of the fissile system to the introduced source from its response to any internal or inherent sources. This ability combined with the enhanced sensitivity of higher order signatures indicates that these techniques will be of significant utility ...

1998-04-01

228

PROBABILISTIC SAFETY ASSESSMENT OF OPERATIONAL ACCIDENTS AT THE WASTE ISOLATION PILOT PLANT  

Energy Technology Data Exchange (ETDEWEB)

This report presents a probabilistic safety assessment of radioactive doses as consequences from accident scenarios to complement the deterministic assessment presented in the Waste Isolation Pilot Plant (WIPP) Safety Analysis Report (SAR). The International Council of Radiation Protection (ICRP) recommends both assessments be conducted to ensure that ''an adequate level of safety has been achieved and that no major contributors to risk are overlooked'' (ICRP 1993). To that end, the probabilistic assessment for the WIPP accident scenarios addresses the wide range of assumptions, e.g. the range of values representing the radioactive source of an accident, that could possibly have been overlooked by the SAR. Routine releases of radionuclides from the WIPP repository to the environment during the waste emplacement operations are expected to be ...

2000-09-01

229

Comparison of radon exposure assessment results: {sup 210}Po surface activity on glass objects vs. contemporary air radon concentration  

Energy Technology Data Exchange (ETDEWEB)

Radon exposure assessment in case-control studies on radon and lung cancer is generally based on contemporary radon concentration measurements, which can be affected by significant changes in the building structures or in living habits. Another method to estimate the radon exposure of the subjects is the recently developed retrospective dosimetry technique based on the {sup 210}Po surface activity from glass objects. In order to compare the results obtained by the two methods, a study has been carried out in a sample of 26 dwellings in Rome, with radon concentration values ranging from 28 to 623 Bq m{sup -3}. Retrospective detectors based on CR-39 and LR 115 were exposed on 50 glass objects in bedrooms and living rooms. The correlation factor between the two sets of data, after removing six extreme values, is 0.67, which is similar to results obtained in other validation studies of similar sample size. The correlation increases to 0.83 if the ...

2003-06-01

230

Self-assessment of current knowledge in nuclear medicine (second edition)  

Energy Technology Data Exchange (ETDEWEB)

In this updated second edition, the order of contents of the textbook has been reorganized. It has been divided into main parts: Basic Science and Clinical Nuclear Medicine. Basic Science, Part I, encompasses basic physics, radiation protection, interaction of radiation with matter and radiation detection, imaging, nuclear pharmacy, and radiation biology. Part II, Clinical Nuclear Medicine, covers the central nervous system, bone, gastroenterology (liver/spleen), cardiovascular system, pulmonary system, genitourinary system, thyroid and endocrine systems, gallium studies, radioassay, hematology, and therapy. The total number of pages of the current edition is increased to 250 from the 213 of the first edition but there are fewer questions because those in the basic science area have been carefully selected to 60 of the original 98 questions. Compared with the previous edition, there are two advantages ...

1981-01-01

231

Life evaluation of insulating materials for electric cable by accelerated thermal-radiation combined aging. 2  

International Nuclear Information System (INIS)

Radiation-and-thermal-combined degradation of some kinds of cable insulating and jacketing materials was evaluated by accelerated aging tests. Plasticized polyvinyl chloride (PVC), silicone rubber, crosslinked and non-crosslinked halogen-free flame-retardant polyolefins (NH-XLPO and NH-PO) and ethylene-propylene rubber (EP rubber) of experimental formulation were degraded at accelerated rates, that are 50-1000 times the degradation rate under standard conditions (e.g.; 1Gy/h, 50degC), and a method to assess the lifetime of these materials under standard conditions was studied. The degradation was investigated by measuring tensile properties. In the accelerated aging tests, rates of elongation decrease owing to degradation for these materials were in proportion to the increase in accelerated rate. The PVC lifetime estimated from sequential aging tests had a tendency to extend beyond that from simultaneous aging tests, while the lifetime of other ...

1994-01-01

232

Behavioral effects of exposure to the TEMPO high-power microwave system. Interim report, January-June 1987  

Energy Technology Data Exchange (ETDEWEB)

Safety standards for exposure to radiofrequency radiation must be based upon biologic consequences of exposure to such environments. Behavioral-based measures are considered to be the most-sensitive indices of biological effects. Current safety guidelines are based upon average power density and may not be relevant to the high-peak-power, short pulse width microwave radiation produced by newly developed high peak power microwave sources. The effects of exposure to high-peak-power radiation on reflexive responding and motor function in Fischer 344/N rats were assessed by measuring startle and general activity, and disruption of on-going performance of a rotarod task, respectively. The emitter used was the TEMPO repeat pulse axially extracted vircator. Exposure to single pulses resulted in significant startle responses. Exposure to 1 pps for 10 s produced significant alterations in baseline activity and ...

1988-03-01

233

Application of combined TLD and CR-39 PNTD method for measurement of total dose and dose equivalent on ISS  

Energy Technology Data Exchange (ETDEWEB)

To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca{sub 2}SO{sub 4}:Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let spectrum, dose, and dose equivalent from ...

2006-07-01

234

Indoor radon dose assessment for Osijek  

Energy Technology Data Exchange (ETDEWEB)

After ten years' investigation of radon's seasonal variation at three very different locations, as well as radon concentration measurements in kindergartens, schools, air-raid shelters and cellars, systematic indoor radon measurements were undertaken in dwellings (residential buildings) of Osijek (East Croatia, 130andpuncsp; omitted000 citizens). Indoor radon was measured by means of the LR-115 SSNT detector at 48 town locations that gave an arithmetic mean of 71.6 Bq/m{sup 3}, standard deviation of 44.0 Bq/m{sup 3} and geometric mean of 60.1 Bq/m{sup 3}, for the radon concentration range from 22.7 to 185.6 Bq/m{sup 3}. Radon measurements, performed by the silicon Radhome detector, did not differ significantly. The empirical frequency distribution of radon concentrations, with the class width of 20 Bq/m{sup 3}, was in accordance with the theoretical log-normal distribution which was shown with the {chi}{sup 2}-test. The radon ...

1999-05-01

235

Operation of an 18-fold segmented n-type HPGe detector in liquid nitrogen  

International Nuclear Information System (INIS)

For the first time a segmented n-type HPGe detector was operated directly submerged in liquid nitrogen over a long period. As this kind of detector is envisioned to be used in GERDA phase II, it was operated with a low mass signal cable with snap-contacts and mounted in a low-mass copper holder. The detector performance was stable over 146 days, indicating that neither detector nor contacts deteriorated.

2009-11-01

236

Bragg curve spectroscopy detector for particle identification  

International Nuclear Information System (INIS)

The operation principle, construction and characteristics of the Bragg curve spectroscopy detector (BCS detector) are described. The electric field of the BCS detector is parallel to the particle trajectories. The detector was tested by 8.78 MeV and 6.02 MeV #alpha# particles from a ThC-ThC's source. The energy resolutions are 1.5% and 2.6% respectively for two groups of #alpha# particles, and the charge resolution is 2.7%. Further test experiments with heavy ions will be arranged.

237

X-ray dosimetry of TlGaSe_2 single crystals  

International Nuclear Information System (INIS)

TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. X-ray conductivity coefficients K_#sigma# characterising X-ray ...

238

Regulation of naturally occurring radioactive materials in Australia  

British Library Electronic Table of Contents (United Kingdom)

In order to promote uniformity between jurisdictions, the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) has developed the National Directory for Radiation Protection, which is a regulatory framework that all Australian governments have agreed to adopt. There is a large and diverse range of industries involved in mining or mineral processing, and the production of fossil fuels in Australia. Enhanced levels of naturally occurring radionuclides can be associated with mineral extraction and processing, other industries (e.g. metal recycling) and some products (e.g. plasterboard). ARPANSA, in conjunction with industry and State regulators, has undertaken a review and assessment of naturally occurring radioactive material (NORM) management in Australian industries. This rev...

2011-01-01

239

Principles of protection: a formal approach for evaluating dose distributions  

International Nuclear Information System (INIS)

One of the central issues in radiation protection consists in determining what weight should be given to individual doses in relation to collective or aggregated doses. A mathematical framework is introduced in which such assessments can be made precisely in terms of comparisons between alternative distributions of individual doses. In addition to evaluation principles that are well known from radiation protection, a series of principles that are derived from parallel discussions in moral philosophy and welfare economics is investigated. A battery of formal properties is then used to investigate the evaluative principles. The results indicate that one of the new principles, bilinear prioritarianism, may be preferable to current practices, since it satisfies efficiency-related properties better without sacrificing other desirable properties.

2006-03-01

240

Interinstitutional Variations in Planning for Stereotactic Body Radiation Therapy for Lung Cancer  

British Library Electronic Table of Contents (United Kingdom)

Purpose: The aim of this study was to assess interinstitutional variations in planning for stereotactic body radiation therapy (SBRT) for lung cancer before the start of the Japan Clinical Oncology Group (JCOG) 0403 trial.Methods and Materials: Eleven institutions created virtual plans for four cases of solitary lung cancer. The created plans should satisfy the target definitions and the dose constraints for the JCOG 0403 protocol.Results: FOCUS/XiO (CMS) was used in six institutions, Eclipse (Varian) in 3, Cadplan (Varian) in one, and Pinnacle3 (Philips/ADAC) in one. Dose calculation algorithms of Clarkson with effective path length correction and superposition were used in FOCUS/XiO; pencil beam convolution with Batho power law correction was used in Eclipse and Cadplan; and collapsed co...

2007-01-01

241

First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry  

Energy Technology Data Exchange (ETDEWEB)

A prototype detector based on the inclined boron layer principle is introduced. For typical measurement conditions at the Liquids Reflectometer at the Spallation Neutron Source, its count rate capability is shown to be superior to that of the current detector by nearly two orders of magnitude.

2010-01-01

242

First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry  

Energy Technology Data Exchange (ETDEWEB)

A prototype detector based on the inclined absorber layer principle is introduced. For the Liquids Reflectometer at the Spallation Neutron Source, it is shown to be a significant improvement over its current detector, which imposes an instantaneous count rate limitation of 50 kcps.

2008-10-01

243

Title of paper: the induction of P-53 independent programmed cell death (apoptosis) with ionizing radiation and 5-fluorouracil (5-FU) in the HT-29 human colon carcinoma cell line  

International Nuclear Information System (INIS)

Purpose/Objective: The role of programmed cell death (apoptosis) as a cellular response to cancer therapy such as radiation or chemotherapy is the subject of much study, and manipulation of the apoptotic response in tumor cells may be valuable in the treatment of a variety of cancers. Both p53 dependent and independent apoptotic pathways have been identified; p53 is mutated in at least 50 % of human cancers and a majority of radiation resistant tumors contain p53 mutations. This study is designed to examine the induction of programmed cell death in a human colon carcinoma cell line that possesses two mutated p53 alleles. Ionizing radiation alone, or in combination with the chemotherapeutic drug 5-fluorouracil (5-FU), were used to elicit the apoptotic response. This study will focus on whether these treatments can induce a significant apoptotic response in cells that have mutated p53 alleles. Materials and Methods: HT-29 ...

1996-09-01

244

Measurement of dose-area product in diagnostic radiology as a method of assessing the radiation exposure. (Results, experience, proposals for improvement, recommendations relating to radiological protection). Report of an expert meeting  

International Nuclear Information System (INIS)

The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product measurement in the dosimetry activities in medical ...

245

ESR dosimetry of irradiated chicken legs and chicken eggs  

Energy Technology Data Exchange (ETDEWEB)

Ionising radiation induces stable free radicals in chicken bones and in the shell of chicken eggs which can be detected, by the electrons spin resonance (ESR) technique, well beyond the shelf-life of the food and can be used for dosimetry. The method usually adopted to evaluate ``a posteriori`` the dose given during the ionising radiation treatment of food, is the dose additive method. To assess the dose, the ESR signal amplitude of the irradiated food (bone or egg shell in the present case) is measured and then the dose-effect relationship is obtained by re-irradiating the sample with some additive doses (usually of 1 kGy). The dose-effect curve is back-extrapolated and the initial given dose determined. At the Istituto Superiore di Sanita (ISS), Rome, Italy, a research programme was approved two years ago aimed to, (1) study new methodological approaches for ESR dose assessment, and (2) analyse the ...

1996-12-31

246

First results from the Lund NMP particle detector system  

International Nuclear Information System (INIS)

The design and first results from a Double Sided Silicon Strip Detector (DSSSD) recently installed at the Lund Nuclear Microprobe facility (NMP) are presented. The detector has 64 sector strips and 32 ring strips, which in combination give more than 2000 detector cells, each with characteristics comparable with a standard surface barrier detector (SBD). The detector has been tested both with radioactive sources and with different ion beams and energies. The most striking features are the high rate virtually pile-up free operation and also the possibility of detailed measurement of angular distributions.

2009-06-15

247

First results from the Lund NMP particle detector system  

British Library Electronic Table of Contents (United Kingdom)

The design and first results from a Double Sided Silicon Strip Detector (DSSSD) recently installed at the Lund Nuclear Microprobe facility (NMP) are presented. The detector has 64 sector strips and 32 ring strips, which in combination give more than 2000 detector cells, each with characteristics comparable with a standard surface barrier detector (SBD). The detector has been tested both with radioactive sources and with different ion beams and energies. The most striking features are the high rate virtually pile-up free operation and also the possibility of detailed measurement of angular distributions.

2009-01-01

248

Some comments on BEIR III  

International Nuclear Information System (INIS)

... organizations irradiation radiation doses radiation effects RADIATIONS.

1982-01-01

249

Radiation technology of wood-plastic composite materials  

International Nuclear Information System (INIS)

... radiation effects RADIATIONS. WOOD-PLASTIC COMPOSITES.

1981-10-02

250
251

Naturally radioactive waste materials. Part 1. Assessment and monitoring of materials and residues; Abfaelle mit natuerlicher Radioaktivitaet. Teil 1. Bewertung und Ueberwachung von Materialien und Rueckstaenden  

Energy Technology Data Exchange (ETDEWEB)

The amended Radiation Protection Ordinance of 2001 contains regulations on natural radioactive materials, whose recycling or disposal poses practical problems. There is little experience in this field so far. [German] Die novellierte Strahlenschutzverordnung von 2001 befasst sich auch mit natuerlich vorkommenden radioaktiven Stoffen. Bei ihrer Verwertung oder Beseitigung ergeben sich praktische Fragen, die beachtet werden muessen. Erfahrungen auf diesem Gebiet liegen bisher kaum vor. (orig.)

2003-03-01

252

Microbuckling compression failure of a radiation-induced wood/polymer composite  

Energy Technology Data Exchange (ETDEWEB)

A wood/polymer composite was produced by impregnating Ramin wood with methyl methacrylate monomer and subsequently polymerizing it by gamma irradiation. To assess the improvement in compression strength of the wood caused by the polymer impregnation, a microbuckling compression failure mechanism was used to model the compression failure of the composite. Such a mechanism was found to predict a linear relationship between the compression strength and the percentage polymer impregnation (by weight). Uniaxial compression test results at 45({plus minus}5)% and 90({plus minus}5)% relative humidity levels, after being statistically analysed, showed that such a linear relationship was valid for up to 100% polymer impregnation. (author).

1990-01-01

253

Microbuckling compression failure of a radiation-induced wood/polymer composite  

International Nuclear Information System (INIS)

A wood/polymer composite was produced by impregnating Ramin wood with methyl methacrylate monomer and subsequently polymerizing it by gamma irradiation. To assess the improvement in compression strength of the wood caused by the polymer impregnation, a microbuckling compression failure mechanism was used to model the compression failure of the composite. Such a mechanism was found to predict a linear relationship between the compression strength and the percentage polymer impregnation (by weight). Uniaxial compression test results at 45(#+-#5)% and 90(#+-#5)% relative humidity levels, after being statistically analysed, showed that such a linear relationship was valid for up to 100% polymer impregnation. (author).

1990-01-01

254

Interpolation theory and influence of boundary conditions on room air diffusion  

Energy Technology Data Exchange (ETDEWEB)

This paper analyses the errors caused by interpolation from existing cases for assessing indoor air flow, air quality and thermal comfort in an office. A sensitivity study is then provided to determine the influence of several boundary conditions on indoor air diffusion. The research is conducted numerically by using a low-Reynolds-number k-{epsilon} model. It can be concluded that the interpolation errors caused by the variations of solar radiation, window size, heat source location due to lighting, and the surface temperatures of interior walls are small and can be quantitatively determined. But it is difficult to estimate the errors introduced by the variations of furniture location and size. (author).

1991-01-01

255

Femtosecond Laser Passivation of GaAs Detector Material  

Science.gov (United States)

... The approach is to perform noise spectral density measurements and selected materials structure measurements on GaAs detector materials, with ...

2008-06-07

256

Design and R&D for the forward calorimeter and silicon tracker of the $\\tau$cF detector  

CERN Document Server

Design and R&D for the forward calorimeter and silicon tracker of the $\\tau$cF detector

1993-01-01

257

A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer  

CERN Document Server

A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer

1991-01-01

258

Radiation inactivation target size of rat adipocyte glucose transporter  

Energy Technology Data Exchange (ETDEWEB)

In situ assembly states of rat adipocyte glucose transport protein in plasma membrane (PM) and in microsomal pool (MM) were assessed by measuring target size (TS) of D glucose-sensitive, cytochalasin B binding activity. High energy radiation inactivated the binding in both PM and MM by reducing the total capacity of the binding (B/sub T/) without affecting the dissociation constant (K/sub D/). The reduction in B/sub T/ as a function of radiation dose was analyzed based on classical target theory, from which TS was calculated. TS in the PM of insulin-treated adipocytes was 58 KDa. TS in the MM of noninsulin-treated and insulin-treated adipocytes were 112 and 109 KDa, respectively. With MM, however, inactivation data showed anomalously low radiation sensitivities at low radiation doses showing a shoulder in the semilog plots, which may be due to an interaction with a ...

1987-05-01

259

Severe rectal injury following radiation for prostatic cancer  

Energy Technology Data Exchange (ETDEWEB)

Between 1970 and 1981, 348 patients underwent definitive irradiation. Of these patients 6 (1.7 per cent) sustained severe rectal injury as manifest by major rectal bleeding, rectal stricture, rectal mucosal slough and rectal ulceration. Severe rectal injury was observed in 0 of 13 patients (0 per cent) treated with 125iodine, 3 of 329 (1 per cent) treated with 6,400 to 6,800 rad external irradiation, 2 of 39 (5 per cent) treated with 7,000 to 7,300 rad external irradiation, and 1 of 7 (14 per cent) treated with 198gold and external irradiation. The impact of radiation dose, radiation therapy technique and surgical trauma was assessed. Rectal injury was managed by supportive measures in 2 patients and by diverting colostomy in 3 with benefit. One patient underwent abdominoperineal resection. A small bowel fistula and an intra-abdominal abscess developed, and the patient died.

1984-04-01

260

Risks and safety aspects related to PET/MR examinations  

International Nuclear Information System (INIS)

The introduction of positron emission tomography (PET)/magnetic resonance (MR) systems into medical practice in the foreseeable future may not only lead to a gain in clinical diagnosis compared to PET/computed tomography (CT) imaging due to the superior soft-tissue contrast of the MR technology but can also substantially reduce exposure of patients to ionizing radiation. On the other hand, there are also risks and health effects associated with the use of diagnostic MR devices that have to be considered carefully. This review article summarizes biophysical and biological aspects, which are of relevance for the assessment of health effects related to the exposure of patients to both ionizing radiation in PET and magnetic and electromagnetic fields in MR. On this basis, some considerations concerning the justification and optimization of PET/MR examinations are presented - as far as this is possible at this very early stage. ...

2009-03-01

261

Limiting values of radionuclide intake and air concentration and dose conversion factors for inhalation, submersion, and ingestion: Federal guidance report No. 11  

Energy Technology Data Exchange (ETDEWEB)

Radiation protection programs for workers are based, in the United States, on a hierarchy of limitations stemming from Federal guidance approved by the President. This guidance, which consists of principles, policies, and numerical primary guides, is used by Federal agencies as the basis for developing and implementing their own regulatory standards. The primary guides are usually expressed in terms of limiting doses to workers. The protection of workers against taking radioactive materials into the body, however, is accomplished largely through the use of regulations based on derived guides expressed in terms of quantities or concentrations of radionuclides. The values of these derived guides are chosen so as to assure that workers in work environments that conform to them are unlikely to receive radiation doses that exceed the primary guides. The purpose of the present report is to set forth derived guides that are consistent with current ...

1988-09-01

262

Impact of radiation measurements on hardening of TFTR diagnostics  

International Nuclear Information System (INIS)

Contrary to previous plans for the preparation of diagnostic systems for D-T break-even experiments in the Tokamak Fusion Test Reactor (TFTR), it now appears that a limited Q#approx#1 demonstration can be carried out without constructing a close-fitting igloo radiation shield around the tokamak. In order to assess the impact of D-T operation of TFTR without an igloo shield, particularly with regard to hardening of diagonstic systems, we have mapped neutron and gamma fluxes inside the test cell and test cell basement, using a variety of radiation measurements. The measurements are sufficiently detailed to resolve massive hardware components, such as neutral beams and shielded diagnostic systems, and can be used to predict local fluxes. By comparing the measurements with transport code calculations for the case of a bare tokamak, we conclude that the models have substantially overestimated fluxes both inside and outside the ...

263

Development of radiological emergency preparedness and biological dosimetry technology  

Energy Technology Data Exchange (ETDEWEB)

Large-scale field tracer experiments have been conducted on Ulchin and Wolsung nuclear sites for the purpose of validating FADAS and of analyzing the environmental characteristics around the nuclear site. The most influential factor in atmospheric dispersion is the meteorological condition. During the experiment, meteorological data were measured on the release point and the selected positions among sampling points. Once radioactive materials are released to the atmosphere, members of public may be exposed through the environmental media such as air, soil and foods. Therefore, to protect the public, adequate countermeasures should be taken at due time for those exposure pathways. Both processes of justification and optimization are applied to a countermeasure simultaneously for decision-making. The work scope of biological research for the radiation protection had contained the search of biological microanalytic methods for the assessment of ...

1999-04-01

264

Compatibility analysis of DUPIC fuel (part 3) - radiation physics analysis  

International Nuclear Information System (INIS)

As a part of the compatibility analysis of DUPIC fuel in CANDU reactors, the radiation physics calculations have been performed for the CANDU primary shielding system, thermal shield, radiation damage, transportation cask and storage. At first, the primary shield system was assessed for the DUPIC fuel core, which has shown that the dose rates and heat deposition rates through the primary shield of the DUPIC fuel core are not much different from those of natural uranium core because the power levels on the core periphery are similar for both cores. Secondly, the radiation effects on the critical components and the themal shields were assessed when the DUPIC fuel is loaded in CANDU reactors. Compared with the displacement per atom (DPA) of the critical component for natural uranium core, that for the DUPIC fuel core was increased by -30% for the innermost groove and the weld points ...

2009-07-01

265

X-dosimetry of Tl(InS_2)_1_-_x(FeSe_2)_x single crystals  

International Nuclear Information System (INIS)

Tl(InS_2)_1_-_x(FeSe_2)_x single crystals (where x=0; 0.001; 0.005; 0.01 and 0.015) were grown by the Bridgman-Stockbarger method. Obtained single crystals were crystallized in monoclinic structure. The present paper deals with experimental results relative to X-ray dosimetric characteristics of the Tl(InS_2)_1_-_x(FeSe_2)_x solid solutions at 300 K. Installation URS-55a was the source of radiation. X-ray radiation dose (E) falling on the crystals is measured by the crystalline X-ray dosimeter DRGZ-02. The value of X-ray conductivity coefficient K_#sigma# characterising X-ray sensitivity is defined as K_#sigma#= (#sigma#_E-#sigma#_0)/E#sigma#_0. where #sigma#_E is conductivity under the effect of X-ray radiation by intensity E, #sigma#_0 is conductivity in the lack of radiation. Comparing X-ray dosimetric characteristics of TlInS_2 and Tl(InS_2)_1_-_x(FeSe_2)_x crystals notes that because of partial ...

2003-09-15

266

Liquid and gaseous effluent control and monitoring at Cernavoda NPP and the assessment of the environmental impact  

International Nuclear Information System (INIS)

The release of any potential radioactive pollutant to the environment during routine operation of a Nuclear Power Plant should be the subject of appropriate controls and assessments. It is impossible to monitor directly the dose contribution of normal releases because the environmental radioactivity levels are very small but source monitoring provides a means of assessing the radiation exposure of population groups, critical groups and individual members of the public. Derived emissions limits ( DELs ) are used to quantify the relationship between releases of radioactivity and doses to public - critical groups. CNE Cernavoda DELs are based on a pathway analysis conducted for Cernavoda site specific conditions and they were computed using a compartment transfer model. Annual air and water emissions for the most significant radionuclides between 1997 and 2008 are presented in terms of doses and can be observed that population ...

2009-10-12

267

Recent developments and applications for the University of Texas thermal neutron imaging facility  

Energy Technology Data Exchange (ETDEWEB)

The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system resolution have hot been determined. The TNIF is currently being revamped to begin work with the non-destructive evaluation (NDE) of ...

2001-07-01

268

Radiological characterization of the GRR-1 pool  

International Nuclear Information System (INIS)

GRR-1 is a 5MW open pool type research reactor with MTR-type fuel elements cooled and moderated by light water with beryllium reflectors at the two opposing sides of the core. A graphite thermal neutron column is adjusted to one side of the core. Six radial horizontal beam tubes are available, of which three contain in-pile collimators for neutron scattering instruments. The reactor is currently out of operation for inspection and refurbishment purposes. The core has been dismantled and the fuel elements are stored in the used fuel storage tank. The GRR-1 inspection and refurbishment plan involves inspection and eventually replacement of the reactor's primary cooling circuit. The health physics procedures to be implemented during inspection of the main water outlet are divided in three stages: a) pool dose rate survey from pool top, b) pool drainage by decreasing water level in steps and c) inspection of the water main outlet. urpose of the present work is the evaluation of the gamma ...

2007-11-05

269

Development of a neutron/. gamma. ray radiation monitor  

Energy Technology Data Exchange (ETDEWEB)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/..gamma.. ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time ..gamma.. spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded ..gamma.. spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations ...

1983-01-01

270

Development of a neutron/#gamma# ray radiation monitor  

International Nuclear Information System (INIS)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/#gamma# ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time #gamma# spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded #gamma# spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations using ...

1983-01-01

271

Development of a Neutron/gamma Ray Radiation Monitor.  

Science.gov (United States)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/gamma ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time gamma spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded gamma spectra created by the photopeak-compton edge combination in the plateau portion of the knee response, correcting equations using a ...

1983-01-01

272

A search for. nu. sub e appearance from stopped. pi. sup + and. mu. sup + decay at LAMPF (Los Alamos Meson Physics Facility)  

Energy Technology Data Exchange (ETDEWEB)

We report on a recent search for {bar {nu}}{sub e} appearance from stopped {pi}{sup +} {yields} {mu}{sup +}{nu}{sub {mu}} and {mu}{sup +} {yields} e{sup +}{nu}{sub e}{bar {nu}}{sub {mu}} decay made by the LAMPF experiment E645. The appearance of {bar {nu}}{sub e} may occur from {bar {nu}}{sub {mu}} {yields} {bar {nu}}{sub e}, {nu}{sub e} {yields} {bar {nu}}{sub eL}, or {nu}{sub {mu}} {yields} {bar {nu}}{sub eL} oscillations. Appearance may also occur from rare {mu}{sup +} {yields} e{sup +}{bar {nu}}{sub e}{nu}{sub {mu}} decay, which is allowed by a multiplicative lepton charge conservation law. The neutrino energies range from E{sub {nu}} = 0 to 52.8MeV. The neutrino detector, which is located 26.1 meters from the neutrino source, consists of a segmented liquid scintillator and proportional drift tube central detector surrounded by both active and passive shielding. The central detector detects {bar {nu}}{sub e} through the ...

1990-01-01

273

Recent progress of the JAERI free electron laser driven by a compact superconducting RF linac  

International Nuclear Information System (INIS)

A prototype for a quasi-cw, and high-average power free electron laser (FEL) driven by a 15 MeV superconducting rf linac has been developed, and constructed at Tokai, JAERI since 1989. Cryogenic and accelerating fields' performances of four JAERI superconducting accelerator modules have been realized without any serious problem in the FEL accelerator vault and experimental hall. Since modification and related maintenance of the cryogenic refrigerator system for the driver were completed in the middle of October 1995, the system has run with no trouble, and the driver has been continuously run very successfully up to now. The optical resonator system and related electron beam transport system have been modified to realize larger acceptance than the old for both of the undulator radiation and energetic electron beam in 1995 Japanese fiscal year. In the modification, an alignment and distance measurement system has been newly developed, and successfully applied to ...

1997-02-28

274

Use of neutron and gamma ray spectral measurements and calculations to obtain dosimetric information for DT neutrons  

Energy Technology Data Exchange (ETDEWEB)

Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, spectrometry, kerma distributions, coupled multigroup calculations

1983-01-01

275

Use of neutron and gamma ray spectral measurements and calculations to obtain dosimetric information for DT neutrons  

International Nuclear Information System (INIS)

Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, spectrometry, kerma distributions, coupled multigroup calculations.

7871-01-01

276

Untersuchung von Bildqualitat und Genauigkeit der Dosisberechnung bei cone-beam-CT-Aufnahmen mit reduziertem Projektionsdatensatz (half scan, half fan) im Hinblick auf die Verwendbarkeit fur die adaptive Bestrahlungsplanung  

British Library Electronic Table of Contents (United Kingdom)

Subject of this study is the question of whether cone beam CT (CBCT) images with reduced projection data are suitable for use in adaptive radiation therapy (ART) treatment planning. For this purpose image quality and dose calculation accuracy depending on imaging modality were analysed. In this context, two CBCT-methods will be indicated having reduced projection data sets: Scans acquired with 200^o rotation angle in order to accelerate the CBCT process (half scan), or scans with an asymmetric cone beam and detector offset, used to enlarge the field-of-view (half fan). Methods: For three different CBCT-modes (On-Board-Imaging, Varian Medical Systems), two of them based on reduced projection data, and a conventional multidetector CT system, the main image quality parameters were studied. Tr...

2011-01-01

277

Study of e{sup +}e{sup -}{yields}pp using initial state radiation with BABAR  

Science.gov (United States)

The e{sup +}e{sup -}{yields}pp cross section is determined over a range of pp masses, from threshold to 4.5 GeV/c{sup 2}, by studying the e{sup +}e{sup -}{yields}pp{gamma} process. The data set corresponds to an integrated luminosity of 232 fb{sup -1}, collected with the BABAR detector at the PEP-II storage ring, at an e{sup +}e{sup -} center-of-mass energy of 10.6 GeV. The mass dependence of the ratio of electric and magnetic form factors, G{sub E}/G{sub M}, is measured for pp masses below 3 GeV/c{sup 2}; its value is found to be significantly larger than 1 for masses up to 2.2 GeV/c{sup 2}. We also measure J/{psi}{yields}pp and {psi}(2S){yields}pp branching fractions and set an upper limit on Y(4260){yields}pp production and decay.

2006-01-01

278

Radon concentrations and absorbed dose measurements in a Pleistocenic cave  

International Nuclear Information System (INIS)

Radon concentration measurements were carried out using solid-state nuclear track-etch detectors (SSNTDs) type CA 80-15 cellulose nitrate films, in a Pleistocenic cave at Petralona, in Halkidiki, Northern Greece, at 55 km from the city of Thessaloniki. Radon levels as high as 88 kBqxm"-"3 (2.38 nCi x l"-"1) have been recorded inside the cave equivalent to 11.90 WL in terms of occupational exposure to radon and its decay products. Absorbed dose rates were performed using TL dosimeters, type TLD-200 (CaF_2-Dy) in a continuous monitoring program (integrated measurements). Dose rate levels as high as 110 nGy x h"-"1 were recorded inside the cave. In interpreting the high levels of radiation doses, radioactivity measurements regarding the naturally occurring "2"3"8U, "2"3"2Th and "4"0K radionuclides were carried out in various speleothems found at different sites in the cave. (author)

2003-10-01

279

Photon dosimetry using plastic scintillators in pulsed radiation fields  

Energy Technology Data Exchange (ETDEWEB)

Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbed dose to 12 MeV absorbed dose of 0.66 at a distance of 91.4 m from the accelerator. This is compared with an idealized model simulation ...

2007-04-01

280

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial pilot studies with prototype animal PET/MRI ...

2008-06-01

281

Muon trigger, flavour tagging and physics performance of the LHCb experiment; Trigger a muons, etiquetage de la saveur et performances physiques de l'experience LHCb  

Energy Technology Data Exchange (ETDEWEB)

The LHCb experiment that is being settled in CERN is dedicated to the study of CP violation and rare decays in the field of beauty hadrons. The phenomenological background necessary to an adequate understanding of the physics of flavor is presented in the first chapter, it is shown how the flavordynamics can open the way to new physics. The second chapter is dedicated to a brief presentation of the LHCb detector. Two aspects of the design of the muon trigger are more detailed: the radiation resistance of the opto-electronic transmitters and the simulated performances of the trigger. The third chapter reviews the tasks linked to the tagging of the savors of B mesons which will be an important step in all the experiments made at LHCb. The recent progress in heavy savor physics as well as the expected contribution of LHCb in this field are presented in the fourth chapter, especially the search for new physics in penguin diagrams b {yields} s.

2007-10-15

282

Conceptual fusion power monitor based on the "1"6O(n,p)"1"6N reaction  

International Nuclear Information System (INIS)

The feasibility of developing a fusion power monitor based on a fluid activation detector is considered here. The activation fluid may be either a liquid or a gas and its composition can be selected from a number of candidate materials to provide desired activation and decay characterisitcs. Performance calculations indicate that ordinary water would be a nearly ideal activation fluid. The "1"6O(n,p)"1"6N reaction has a threshold at about 10 MeV and a cross section energy dependence giving it a predominant response for unmoderated D-T fusion neutrons. Adequate activation can be obtained at moderate flow rates for remote counting away from the high radiation area of the reactor. The 7.16 sec half-life of "1"6N is ideal for remote counting with subsequent decay in a small hold-up tank to eliminate activity build-up in the recycled water.

1981-07-01

283

Coated semiconductor devices for neutron detection  

Energy Technology Data Exchange (ETDEWEB)

A device for detecting neutrons includes a semi-insulated bulk semiconductor substrate having opposed polished surfaces. A blocking Schottky contact comprised of a series of metals such as Ti, Pt, Au, Ge, Pd, and Ni is formed on a first polished surface of the semiconductor substrate, while a low resistivity ("ohmic") contact comprised of metals such as Au, Ge, and Ni is formed on a second, opposed polished surface of the substrate. In one embodiment, n-type low resistivity pinout contacts comprised of an Au/Ge based eutectic alloy or multi-layered Pd/Ge/Ti/Au are also formed on the opposed polished surfaces and in contact with the Schottky and ohmic contacts. Disposed on the Schottky contact is a neutron reactive film, or coating, for detecting neutrons. The coating is comprised of a hydrogen rich polymer, such as a polyolefin or paraffin; lithium or lithium fluoride; or a heavy metal fissionable material. By varying the coating thickness and electrical settings, neutrons at specific ...

2002-01-01

284

An aerial radiological survey of the Hanford Site and surrounding area, Richland, Washington  

International Nuclear Information System (INIS)

An aerial radiological survey was conducted over the Department of Energy's Hanford Site near Richland, Washington, during the period 5 July through 26 August 1988. The survey was expanded, and additional flights were conducted to the east of the site and along the banks of the Columbia River down to McNary Dam near Umatilla. The survey was flown at altitude of 61 meters (200 feet) by a helicopter containing 17 liters (eight 2 in. x 4 in. x 16 in.) of sodium iodide detectors. Gamma ray data were collected over the survey area by flying north-south lines spaced 122 meters (400 feet) apart. The processed data indicated that detected radioisotopes and their associated gamma ray exposure rates were generally consistent with those expected from normal background emitters and man-made fission/activation products resulting from activities at the site. External exposure rates were generally 10 microroentgens per hour (#mu#R/h) with some operating areas over 1000 #mu#R/h. ...

1990-09-16

285

A superconducting solenoidal spectrometer for a balloon-borne experiment  

Energy Technology Data Exchange (ETDEWEB)

The BESS detector is a new type of balloon-borne spectrometer which utilizes various technologies recently developed for collider experiments. The principal scientific objectives include a measurement of cosmic-ray antiproton spectrum, search for anti-nuclei in cosmic radiation, and precise measurements of cosmic-ray primaries. A thin superconducting solenoidal coil produces a uniform magnetic field of 1 T. Cylindrical drift chambers are located inside and outside the coil and perform continuous tracking. The momentum resolution is 0.5% at 1 GeV/c. i.e., the maximum detectable rigidity is 200 GV. Scintillation counter hodoscopes, placed above and below the solenoid, provide timing and dE/dx measurements and trigger generation. The timing resolution is 80 ps/counter. This cylindrical configuration achieves a large geometrical acceptance of 0.35 m{sup 2} sr which is essential to detect rare cosmic-ray particles. In order to cope with high trigger ...

2000-03-21

286

{sup 252}Cf-source-driven frequency analysis measurements with subcritical arrays of PWR fuel pins  

Energy Technology Data Exchange (ETDEWEB)

Experiments with fresh PWR fuel assemblies were performed to assess the {sup 252}Cf-source-driven frequency analysis method for measuring the subcriticality of spent fuel. The measurements at the Babcox and Wilcox Critical Experiments Facility mocked up between 17x17 fuel pins (single assembly) and a full array of 4961 fuel pins (about 17 fuel assemblies) in borated water with a fixed B concentration. For the full array, the B content of the water was varied from 1511 at delayed criticality to 4303 ppM. Measurements were done for various source-detector-fuel pin configurations; they showed high sensitivity of frequency analysis parameters to B content and fissile mass. Parameters such as auto and cross power spectral densities can be calculated directly by a more general model of the Monte Carlo code (MCNP-DSP). Calculation-measurement comparisons are presented. This model permits the validation of neutron and gamma ray transport calculational ...

1996-08-01

287

Study of metal concentration in sediment of some springs of Lebanon  

International Nuclear Information System (INIS)

Full text.Surficial sediment samples were collected from seventeen springs distributed all over Lebanon (east, west, north and south). Concentrations of metals Ca, Fe, Mn, Ni, Cu, Cr, Zn and Pb were determined by energy dispersive x-ray fluorescence technique. Irradiation was done by the radioisotope source Cd-109 and the detection by an EG and G Si(Li) detector. These analysis was done in attempt to assess the impact of anthropogenic sources on ground water quality. Metals concentration in sediment were found to be (Ca:0.05-47%, Fe:0.24-4.2%, Cr:

1999-11-02

288

Determination of americium in plutonium based nuclear fuel materials: An assessment of different methodologies  

International Nuclear Information System (INIS)

Determination of americium (Am) is one of the requirements of chemical quality assurance of plutonium (Pu) bearing fuel materials. Though many methods are published for determining Am at picogram to femtogram levels in environmental and biological matrices, yet a few of them are used routinely for Pu based nuclear fuel samples. This paper gives a brief summary of the different analytical methods available and presents results of our experiments on the determination of Am in Pu bearing fuels using gamma spectroscopy. The methods utilizing gamma emissions from "2"4"1Am and Pu isotopes are fast as they do not involve chemical separation of Pu and Am, do not require an accurate knowledge of the efficiency values of the detector systems and are not dependent on the availability of a radiometric standard for "2"4"1Am. In addition, for aged Pu samples containing large amounts of "2"4"1Am, there is no need for dilution and this reduces the volume of analytical radioactive ...

2010-11-15

289

Application of passive and active methods parallel to the measurements of local climatic parameters for the assessment of Rn-222 behaviour in selected Swiss dwellings  

International Nuclear Information System (INIS)

Sources of radon and pathways in which radon can reach dwelling-rooms are shortly discussed. In continuation of the previous measurements of radon in Swiss dwellings with track detectors and working level monitors, a complementary passive method for radon concentration measurements indoors and radon exhalation rate measurements from walls and soil surfaces is introduced. Radon decay products concentrations, air temperature gradients and wind velocities were measured continuously in four Swiss dwellings during several weeks in autumn and winter of 1985/86. The Rn-222 concentrations indoors ranged from about 10 Bq/m"3 in two houses in the Eastern Jura up to more than 23,000 Bq/m"3 in two houses situated in the Central Alps. Indoor equilibrium factors between 0.1 up to 0.5 with distinct dependences on floor-levels have been found. The influence of the temperature gradient between the oudoor and indoor air on the indoor radon daughter concentration has been determined. ...

290

Verification of lithium detector efficiency using DD neutron  

International Nuclear Information System (INIS)

The detection efficiency of a lithium glass detector was calculated using MCNP code, and the calculation was compared with the published results in Pulsed Sphere Plan. A lithium glass detector of our own was made, and its neutron efficiency was calculated. The calculated neutron efficiency was verified with both pulsed and steady DD neutrons. Characteristics of Neutron response of "6Li detector was discussed. (authors)

2005-08-01

294

Developments and tests of double-sided silicon strip detectors and read-out electronics for the Internal Tracking System of ALICE at LHC  

CERN Document Server

The internal-tracking-system (ITS) of the ALICE detector at LHC, consists of six concentrical barrels of silicon detectors. The outmost two layers are made of double-sided strip detectors (SSD). In the framework of a R and D, the characteristics and performances of these devices, manufactured by two different companies, associated with their designed read-out electronics, have been studied off- and in-beam at the SPS (CERN). The results are presented and discussed.

1999-01-01

295

Application of Pd silicide in the process of silicon detectors  

Energy Technology Data Exchange (ETDEWEB)

A new technology called a self-aligned metal-silicide process is described in the fabrication of silicon detectors. It has been found that this technology improves both detector yield and leakage current. The use of a metal silicide also gives a lower contact resistance and, depending on the thermal process, a controllable junction depth, which may be essential in the integration of detectors and their electronics.

1990-04-01

296

Thin-film UV detectors based on hydrogenated amorphous silicon and its alloys  

Energy Technology Data Exchange (ETDEWEB)

Thin film ultraviolet detectors based on hydrogenated amorphous silicon alloys are realized with different diode structures (PIN, NIP, PN, and NP). The PIN and NIP detectors exhibit higher sensitivity in the ultraviolet spectrum and a significant lower dark current in comparison to the PN or NP structures. The best detector performance was achieved with a 33 nm thick PIN diode. This detector shows a maximum of quantum efficiency of 36.3% at a wavelength of 310 nm. By varying the thickness of the semi-transparent Ag front contact the selectivity of the detectors with the quantum efficiency peak at 320 nm can be adjusted. Thus, the spectral sensitivity of the detector shifts from a broad UV to a selective UV-B spectrum. (orig.)

2001-05-16

297

Development of a small scintillation detector with an optical fiber for fast neutrons  

International Nuclear Information System (INIS)

To investigate the characteristics of a reactor and a neutron generator, a small scintillation detector with an optical fiber with ThO_2 has been developed to measure fast neutrons. However, experimental facilities where "2"3"2Th can be used are limited by regulations, and S/N ratio is low because the background counts of this detector are increase by alpha decay of "2"3"2Th. The purpose of this study is to develop a new optical fiber detector for measuring fast neutrons that does not use nuclear material such as "2"3"2Th. From the measured and calculated results, the new optical fiber detector which uses ZnS(Ag) as a converter material together with a scintillator have the highest detection efficiency among several developed detectors. It is applied for the measurement of reaction rates generated from fast neutrons; furthermore, the absolute detection efficiency of this ...

2011-02-01

298

Design and fabrication of large ultra-thin PIN detector with membrane stress deviation  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the design of large thin PIN detector with a membrane stress avoidance configuration is proposed, and the related device fabrication process is developed. Ultra-thin PIN detector {approx} 1.13 cm{sup 2} in area is fabricated on a thin ( {approx} 35{mu}m) silicon membrane, and characterized. Detector performance improvement has been successfully demonstrated. With the membrane stress avoidance design, the improved detector exhibits a leakage of 6nA, which is at least 5 times lower than that of detector of identical junction area. The new detector features a full depleted capacitance of 110 pF, and a FWHM of 40.86 keV energy resolution for 5.486 MeV alpha particle spectrography.

2010-09-15

299

Exposure of Finnish population to solar UV radiation and consequent carcinogenic effects  

Energy Technology Data Exchange (ETDEWEB)

Depletion of stratospheric ozone increases irradiance of terrestrial ultraviolet (UV) radiation at short wavelengths, which may be harmful to the human health. To understand quantitatively the risks caused by increasing UV radiation to the Finnish population, the actual UV exposure of the population has to be assessed. It was shown that the snow reflection increases the UV exposure to the face and eyes particularly in the northern Finland. In 1993 exceptionally low ozone levels persisted up to the end of May, which resulted in a theoretical increase in the annual UV dose ranging from 8 % to 13 % in Finland. The maximal increase in the measured erythemally effective dose rate was 34 % on 23 April, when compared with the theoretical normal value. During this study exposure models have been developed. The models have been combined them with Green`s radiation transfer model to estimate annual facial UV ...

1996-12-31

300

Core simulations using actual detector readings for a Canada deuterium uranium reactor  

Science.gov (United States)

This paper reports that, to obtain better simulation results for a Canada deuterium uranium (CANDU) reactor operation, a new simulation method is developed that uses actual detector readings as a correction factor. Detector readings from a CANDU reactor are used to correct the calculated flux distribution during core calculation iterations. A suitable function is found to describe the relationship between the detector flux and the fluxes of mesh points around the detector. The new simulation method is tested by performing numerical calculations for the Wolsung reactor (a CANDU-600). The results show that the new method predicts the core state more accurately with fewer iterations.

1991-02-01

301

Cellular Sources of Transforming Growth Factor-? Isoforms in Early and Chronic Radiation Enteropathy  

Science.gov (United States)

The three mammalian transforming growth factor (TGF)-? isoforms (TGF-?1, TGF-?2, and TGF-?3) differ in their putative roles in radiation-induced fibrosis in intestine and other organs. Furthermore, tissue specificity of TGF-? action may result from temporal or spatial changes in production and/or activation. The present study examined shifts in the cell types expressing TGF-? mRNA relative to TGF-? immunoreactivity and histopathological injury during radiation enteropathy development. A 4-cm loop of rat small intestine was locally exposed to 0, 12, or 21-Gy single doses of x-irradiation. Sham-irradiated and irradiated intestine were procured 2 and 26 weeks after irradiation. Cells expressing the TGF-?1, TGF-?2, or TGF-?3 transcripts were identified by in situ hybridization with digoxigenin-labeled riboprobes. Intestinal wall TGF-? immunoreactivity was measured using computerized image analysis, and structural radiation ...

1998-11-01

302

Quantification of radionuclide transfer in terrestrial and freshwater environments for radiological assessments  

International Nuclear Information System (INIS)

For more than thirty years, the IAEA has published a set of documents aimed at the limitation of the radiation exposure of the population from various nuclear activities. In particular, in 1994 the IAEA published Technical Reports Series No. 364, Handbook of Parameter Values for the Prediction of Radionuclide Transfer in Temperate Environments. Over the years, it has proved to be a valuable reference for radioecologists, modellers and authorities in Member States, and has been quoted in numerous impact assessments. Technical Reports Series No. 364 was based on a review of available data up to the end of 1992. However, a number of high quality critical reviews have been produced in recent years for some of the transfer parameter values which merit consideration. Thus, it was assumed that there is sufficient new information available to warrant reconsideration of a significant proportion of the values given in Technical Reports Series No. 364 and ...

1993-04-05

303

How to assess risk from combined exposures to radiation and other agents?  

Energy Technology Data Exchange (ETDEWEB)

Efforts to assess and quantify deleterious effects from toxicants concentrate mainly on single agents whereas real world environmental and occupational exposures to natural and anthropogenic agents entail quite often the concomitant presence of several toxicants. For occupational important exposure situations, combined exposures to physical and chemical agents such as radon and smoking or asbestos and smoking, respectively, were shown to produce over-additive effects at exposure levels typical for earlier workplaces. Already the elucidation of possible health risks from a single agents, its dependence on exposure level, exposure rates, age at exposure and its expression in time is a complex endeavour. Therefore in the past and the present the main emphasis in radiation protection, toxicology, and public health is on the study and assessment of single toxicants. The existing data base on combined effect is rudimentary, ...

1997-03-01

304

Studies on formation and structures of ultrafine Cu precipitates in Fe-Cu model alloys for reactor pressure vessel steels using positron quantum dot confinement in the precipitates by their positron affinity. JAERI's nuclear research promotion program, H11-034 (Contract research)  

Energy Technology Data Exchange (ETDEWEB)

Positron annihilation experiments on Fe-Cu model dilute alloys of nuclear reactor pressure vessel (RPV) steels have been performed after neutron irradiation in JMTR. Nanovoids whose inner surfaces were covered by Cu atoms were clearly observed. The nanovoids transformed to ultrafine Cu precipitates by dissociating their vacancies after annealing at around 400degC. The nanovoids and the ultrafine Cu precipitates are strongly suggested to be responsible for irradiation-induced embrittlement of RPV steels. Effects of Ni, Mn and P addition on the nanovoid and Cu precipitate formations were also studied. The nanovoid formation was enhanced by Ni and P, but suppressed by Mn. The Cu precipitates after annealing around 400degC were almost free from these doping elements and hence were pure Cu in the chemical composition. Furthermore the Fermi surface of the 'embedded' Cu precipitates with a body centered cubic crystal structure was obtained from two dimensional angular ...

2003-03-01

305

In situ texture analysis under applied load  

International Nuclear Information System (INIS)

The in-situ measurement of a crystallographic texture is a special type of a non-destructive measurement, which need special equipments. Due to the high photon flux and the excellent brilliance high energetic synchrotron radiations are a fantastic tool particular in fast experimentation. Moreover, a high penetration power allows the investigation of standard tensile sample of the DIN-norm. A loading device with a power up to 20 kN was installed at the hard wiggler beamline BW5 (HASYLAB-DESY) to perform in-situ strain and in-situ texture analysis. Using 100keV X-rays one gets short wavelength so that a 2D image-plate detector offers a wide range of diffraction pattern within the first 10 degree in 2 theta. Thermal neutron is another radiation with a high penetration power, which is the standard method for global texture analysis of bulk samples. As an example rectangular extruded Mg- Az31 was investigated by an in-situ. ...

306

First Observation of Radiative B^0 -> \\phi K^0 \\gamma Decays and Measurements of Their Time-Dependent CP Violation  

CERN Document Server

We report the first observation of the radiative decay B^0 -> \\phi K^0 \\gamma using a data sample of 772 x 10^6 B B-bar pairs collected at the \\Upsilon(4S) resonance with the Belle detector at the KEKB asymmetric-energy e^+e^- collider. We observe a signal of 37+/-8 events with a significance of 5.4 standard deviations including systematic uncertainties. The measured branching fraction is ${\\cal B}(B^0 -> \\phi K^0 \\gamma) = (2.74\\pm 0.60 \\pm 0.32) \\times 10^{-6}$, where the uncertainties are statistical and systematic, respectively. We also report the first measurements of time-dependent CP violation parameters: ${\\mathcal S}_{\\phi K_S^0 \\gamma} = +0.74^{+0.72}_{-1.05} (stat)^{+0.10}_{-0.24} (syst)$ and ${\\mathcal A}_{\\phi K_S^0 \\gamma} = +0.35 +/- 0.58 (stat)^{+0.23}_{-0.10} (syst)$. Furthermore, we measure ${\\mathcal B}(B^+ -> \\phi K^+ \\gamma) = (2.48 +/- 0.30 +/- 0.24) x 10^{-6}$, ${\\mathcal A}_{CP} = -0.03 +/- ...

2011-01-01

307

The Use of Medical Images in Planning and Delivery of Radiation Therapy  

UK PubMed Central (United Kingdom)

Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available

1997-09-01

309
310

Animal Models for Radiation Injury, Protection and Therapy  

Science.gov (United States)

... radiation during clinical therapy and exposures due to radiation accidents or attacks, in which the doses are uncontrolled ... only be used off-label in victims of radiation accidents or attacks. The idea...

311

Segmented focal plane detector for light and heavy ions  

Energy Technology Data Exchange (ETDEWEB)

A segmented focal plane detector for an Enge split-pole spectrograph has been developed for the study of breakup reactions at very low relative energies. It consists of a 61 cm long segmented position-sensitive parallel plate avalanche counter backed by a large Bragg curve detector. A segmented plastic scintillator is mounted behind the anode of the Bragg curve detector and is used for particle identification of low-ionizing particles. The dead space between the two sections of the focal plane detector is 2.5 mm. The intrinsic position resolution of the detector is 1 mm. The intrinsic energy resolution depends on the energy of the incident ion and can be as good as 0.55%. The nuclear charge and mass resolutions are 0.3 e and 0.3 u, respectively. (orig.).

1992-06-15

312

Whole-body counting in the Marshall Islands  

Energy Technology Data Exchange (ETDEWEB)

In 1978 the Marshall Islands Radiological Safety Program was organized to perform radiation measurements and assess radiation doses for the people of the Bikini, Enewetak, Rongelap and Utirik Atolls. One of the major field components of this program is whole- body counting (WBC). WBC is used to monitor the quantity of gamma- emitting radionuclides present in individuals. A primary objective of the program was to establish {sup 137}Cesium body contents among the Enewetak, Rongelap and Utirik populations. {sup 137}Cs was the only gamma-emitting fission radionuclide detected in the 1,967 persons monitored. {sup 137}Cs body burdens tended to increase with age for both sexes, and were higher in males. The average {sup 137}Cs dose Annual Effective Dose for the three populations was as follows: For Enewetak, the dose was 22{+-}4 {mu}Sv. For Utirik, the dose was 33{+-} 3 {mu}Sv. Since 1985 the Rongelap people have been self-exiled ...

1991-01-01

313

Technological physics and special materials: wood-plastic composites obtained by radiation polymerization  

International Nuclear Information System (INIS)

General estimates and references are made in connection with the role of technological physics in obtaining materials with specific features. The first part of the paper presents the modification of weak wood essences as well as technological processes at bench-scale and semi industrial scale of wood-plastic composites, under various irradiation conditions. Two technological installations for the fabrication of wood-plastic composites on both scales with technical and practical specifications of their performances are presented. Experimental data for different wood-plastic composite systems using some local wood essences in combination with several polymer and copolymer systems are given. Impregnation and polymerization levels are mentioned for every specific system. The radiation dose rate and integrated dose are given for every experimental polymerization system. The features of the wood-plastic composites are compared with the initial wood essences. Finally, a ...

1995-12-02

314

Optimisation of imaging technique used in direct digital radiography  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion from being reached. The fact that all images were of diagnostic quality, however, ...

2006-09-15

315

Optimisation of imaging technique used in direct digital radiography  

International Nuclear Information System (INIS)

The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion from being reached. The fact that all images were of diagnostic quality, however, ...

2006-09-01

316

On the determination of the dose-area product during X-ray examinations  

International Nuclear Information System (INIS)

Despite its great usefulness in the performance of the recording procedures prescribed by the X-Ray Ordinance the dose-area product is much less frequently measured for X-ray exposures than during fluorscopic examinations. The great multitude of measuring units, mainly on account of different scales of the measuring equipments themselves, is a cause of uncertainty in clinical routine and should be eliminated as far as the circumstances would permit. As the determination of the organ dose is relevant only in very few cases and does not necessarily require previous measurements of the dose-area product, these are of limited practical value in the assessment of individual radiation exposures during radiographic examinations. The measurements may, however, be very helpful in determinations of the radiation dose to the total population, if the future retrievability of the values obtained is ensured. In addition to some measuring ...

317

Life evaluation of insulating materials for electric cable by accelerated thermal-radiation combined aging  

Energy Technology Data Exchange (ETDEWEB)

Radiation-and-thermal-combined degradation of ethylene-propylene rubber (EP rubber) and chlorosulfonated polyethylene (CSM) as cable insulating and jacketing materials were evaluated by accelerated aging tests and a method to assess the lifetime of these materials under practical application was studied. EP rubber and CSM of experimental formulation were degraded at accelerated rates, that are 50 [approx] 1000 times the degradation rate under a standard condition (1Gy/h, 50degC). The degradation was investigated by measuring the tensile properties. In the accelerated aging tests, rates of elongation decrease owing to degradation for both EP rubber and CSM were in proportion to increase in accelerated rate. Behaviors of elongation changes showed little difference with accelerated rate. EP rubber lifetime estimated from sequential aging test had a tendency to extend beyond that from simultaneous aging test, while CSM lifetime estimated from both ...

1992-10-01

318

Life evaluation of insulating materials for electric cable by accelerated thermal-radiation combined aging  

International Nuclear Information System (INIS)

Radiation-and-thermal-combined degradation of ethylene-propylene rubber (EP rubber) and chlorosulfonated polyethylene (CSM) as cable insulating and jacketing materials were evaluated by accelerated aging tests and a method to assess the lifetime of these materials under practical application was studied. EP rubber and CSM of experimental formulation were degraded at accelerated rates, that are 50 #approx# 1000 times the degradation rate under a standard condition (1Gy/h, 50degC). The degradation was investigated by measuring the tensile properties. In the accelerated aging tests, rates of elongation decrease owing to degradation for both EP rubber and CSM were in proportion to increase in accelerated rate. Behaviors of elongation changes showed little difference with accelerated rate. EP rubber lifetime estimated from sequential aging test had a tendency to extend beyond that from simultaneous aging test, while CSM lifetime estimated from both ...

1992-01-01

319

Critical assessment of the Schroedinger picture of quantum mechanics  

Energy Technology Data Exchange (ETDEWEB)

We provide an example in which the Heisenberg and the Schroedinger pictures of quantum mechanics give different results, thus confirming the statement of P.A.M. Dirac that the two pictures may lead to inequivalent results. We consider a one-dimensional nonrelativistic charged harmonic oscillator (frequency {omega}{sub 0} and mass m), and take into account the action of the radiation reaction and the vacuum electromagnetic forces on the charged oscillator. We show that the Heisenberg picture gives the correct value, {Dirac_h}{omega}{sub 0}/2, for the ground state energy of the harmonic oscillator in both cases of classical and quantized vacuum fields. In the case of the Schroedinger picture, considering classical vacuum fields, and using a simple calculation for the classical radiation reaction force that is valid in the limit of large mass (mc{sup 2} >> {Dirac_h}{omega}{sub 0}), we obtain the value {Dirac_h}{omega}{sub 0} for the ...

2002-12-16

320

The dependence of radiation hardening and embrittlement on irradiation temperature  

International Nuclear Information System (INIS)

Assessments of the hardening and embrittlement of pressure vessel steels and welds as a function of neutron dose use trend curves derived from surveillance programs and accelerated irradiation data. A temperature dependent factor is incorporated for assessing vessel locations operating at different temperatures. As hardening and embrittlement arise from the sum of matrix damage and copper impurity precipitation, the influence of irradiation temperature on each process needs to be established. For irradiations performed below #approx# 300 C recent data shows that the dose-dependent growth of copper precipitates ceases at a mean diameter of about 2 nm that also corresponds to peak hardening and embrittlement by copper. For doses beyond this peak copper dose the property-dependence on irradiation temperature can be identified with that of matrix damage alone. An analysis of several experiments on plate steels, performed at differing irradiation ...

1994-06-20

321

Radiological follow-up of the environment of the G.I.P. CYCERON of Caen - year 2005 - 2006 - assessment 2007; Suivi radiologique de l'environnement des installations du GIP CYCERON de Caen - annee 2005 - 2006 - bilan 2007  

Energy Technology Data Exchange (ETDEWEB)

The present study answers at the request of the Inspection of the classified installations to see the operator of the G.I.P. Cyceron setting up a plan of environmental radiological surveillance around its installations and including, at a minimal level, the following data: Measures of radioactivity on representative biological indicators and measures of dose rate in the environment close to installations in functioning. Further to the radiological assessment of the terrestrial environment of the G.I.P. Cyceron installations realized at the end of 2003, within the framework of a project of the installations extension, the A.C.R.O. was again required for the implementation of this radiological surveillance for year 2005. The first purpose is to supply elements of appreciation about the impact of these installations on environment and persons. This evaluation participates in radiation protection and allows to make sure that the G.I.P. operator ...

2007-07-01

322

Climate change: the Intergovernmental Panel on Climate Change impacts assessment  

Energy Technology Data Exchange (ETDEWEB)

The report was prepared for the IPCC by Working Group II. The remit of Working Group II was to describe the environmental and socioeconomic implications of possible climate changes over the next decades caused by increasing concentrations of greenhouse gases. The scenarios used include the following features: an effective doubling of atmospheric CO{sub 2} between now and 2025-2050; a consequent increase of global mean temperature of 1.5-4.5{degree}C; an unequal global distribution of the temperature increase; a sea level rise of 0.3 to 0.5m by 2050. The impacts of possible climate change were assessed for the following: agriculture and forestry; natural terrestrial ecosystems; hydrology and water resources; human settlements including the energy, transport and industrial sectors; human health; air quality and changes in UV-B radiation; oceans and coastal zones; seasonal snow cover; ice and permafrost. Further action is recommended. 1015 refs., ...

1990-01-01

323

CT-Expo - a novel program for dose evaluation in CT  

International Nuclear Information System (INIS)

CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey on CT practice. Three different application modules offer free and standardized dose calculations as well as a comprehensive benchmarking section ...

2002-12-01

324

A study on the radiation and environmental safety -Development of a real-time radiological dose assessment system-  

Energy Technology Data Exchange (ETDEWEB)

The real-time dose assessment system under development has been updated and the technology for tracer experiment has been established. The calculation of external gamma dose is the most difficult and time-consuming part of the dose calculations. The characteristics of external gamma exposure have been investigated and the method for reducing the calculation time has been devised. The internal exposure via the ingestion of the contaminated foodstuffs is one of the important pathways to the total radiological exposure. In the emergency, it is necessary to take an action such like food ban to protect the internal exposure. An algorithm for the interface between the real-time system and the food chain model has been provided. The second field tracer experiment over flat terrain has been carried out on a plain in Iksan city in Junrabook-Do. Sequential tracer sampler which can be sampled the tracer gas over arbitrary 12 time interval has been designed and manufactured. ...

1995-07-01

325

Development of radiological emergency preparedness technology  

Energy Technology Data Exchange (ETDEWEB)

Large-scale field tracer experiments have been conducted on Ulchin, Wolsung and Daeduk sites for the purpose of validating FADAS and of analyzing the environmental characteristics around the nuclear sites. The most influential factor in atmospheric dispersion is the meteorological condition. During the experiment, meteorological data were measured on the release point and the selected positions among sampling points. Once radioactive materials are released to the atmosphere, members of public may be exposed through the environmental media such as air, soil and foods. Therefore, to protect the public, adequate countermeasures should be taken at due time for those exposure pathways. both processes, of justification and optimization are applied to a countermeasure simultaneously for decision-making. The work scope of Biological research for the radiation protection had contained the search of biological microanalytic methods for assessing the ...

2000-04-01

326

Tissue Heterogeneity in IMRT Dose Calculation for Lung Cancer  

British Library Electronic Table of Contents (United Kingdom)

The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the gamma function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the l...

2011-01-01

327

The radon therapy - radon inhalatorium in Kowary  

International Nuclear Information System (INIS)

In this paper the measurements of radon-222 concentration in the air of Kowary Radon Inhalatorium in the vicinity of Jelenia Gora, Lower Silesia, Poland, performed by Radiation Protection and Radiobiology Department of National Institute of Hygiene in Warsaw, have been presented. For the measurements the integration method with the application of charcoal canisters have been used. The radon concentration was found within the very broad ranges from about 4 to 420 kBq m"-"3 depending of the season of the year. Basing on the radon concentration measurements during the inhalation therapy session and taking into account the equilibrium factor of 0.8 the doses to the bronchi of the patients in range from 1.2 to about 204 mSv (0.12-20.4 rem) have been assessed. The majority of patients (ca. 76%) received the doses between 115 and 204 mSv. (author)

328

Monitoring global land surface drought based on a hybrid evapotranspiration model  

British Library Electronic Table of Contents (United Kingdom)

The latent heat of evapotranspiration (ET) plays an important role in the assessment of drought severity as one sensitive indicator of land drought status. A simple and accurate method of estimating global ET for the monitoring of global land surface droughts from remote sensing data is essential. The objective of this research is to develop a hybrid ET model by introducing empirical coefficients based on a simple linear two-source land ET model, and to then use this model to calculate the Evaporative Drought Index (EDI) based on the actual estimated ET and the potential ET in order to characterize global surface drought conditions. This is done using the Global Energy and Water Cycle Experiment (GEWEX) Surface Radiation Budget (SRB) products, AVHRR-NDVI products from the Global Inventory ...

2011-01-01

329

Low-level radioactive waste disposal in the oceans  

Energy Technology Data Exchange (ETDEWEB)

A strategy for the management of the disposal of low-level radioactive wastes into coastal zones and ocean waters has developed over the past three decades. While there has been a substantial increase in the number of international and required agreements there has also been a concomitant improvement in our understanding of the ocean and the processes at work within it. This has allowed more rigorous and reliable assessments to be made of the radiological consequences. With the continued development of basic guidelines of radiological protection by the International Commission on Radiological Protection (ICRP) methodologies have been formulated to derive the fundamental scientific requirement - the relationship between disposal or release rate to the ocean and the resultant radiation dose to exposed human populations.

1983-04-01

330

Influence of gamma irradiation on waste poly(propylene) composites containing talc and high crystallinity poly(propylene)  

British Library Electronic Table of Contents (United Kingdom)

Commercial polyolefin, such as poly(propylene), are widely used because of their easy processing and their excellent mechanical and thermal properties. Although their recycling is well established, the mechanical and thermal properties of the recycled waste poly(propylene)(WPP) are normally lower than those of the virgin material. The introduction of talc can improve the toughness, without compromising the processability and recycling capabilities. However, the thermal properties of these blends should be assessed to limit degradation during recycling. The effect of gamma radiation on the thermal and mechanical properties of WPP/High Crystallinity Poly(propylene)/Talc was studied. TGA, DSC, and electrical conductivity performed the characterization of WPP composites. Mechanical properties ...

2008-01-01

331

Development of barcode system for internal dose monitoring  

International Nuclear Information System (INIS)

In Tarapur Atomic Power Station unit-3 and 4, which is 540 MWe pressurized heavy water reactor, tritium is produced in primary heat transport system and moderator system. Tritium is a major contributor to the internal dose. Internal dose contributes about 30% of the collective dose. Internal dose monitoring and its control are important to control the collective dose. Estimation of internal dose is done by analysis of bioassay samples of radiation workers. In a month, about 7000 bioassay samples are analysed for the internal dose assessment during normal operation, and about 12000 during the biennial shut down of the reactor. To enhance the sample preparation and counting performance, minimize the entry errors and reduce the processing time, barcode based label generation system was developed for the internal dose monitoring. This paper discusses about the use of barcode system in the internal dose monitoring at TAPS 3 and 4. (author)

2008-11-19

332

Biological effects and physical safety aspects of NMR imaging and in vivo spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

An assessment is made of the biological effects and physical hazards of static and time-varying fields associated with the NMR devices that are being used for clinical imaging and in vivo spectroscopy. A summary is given of the current state of knowledge concerning the mechanisms of interaction and the bioeffects of these fields. Additional topics that are discussed include: (1) physical effects on pacemakers and metallic implants such as aneurysm clips, (2) human health studies related to the effects of exposure to nonionizing electromagnetic radiation, and (3) extant guidelines for limiting exposure of patients and medical personnel to the fields produced by NMR devices. On the basis of information available at the present time, it is concluded that the fields associated with the current generation of NMR devices do not pose a significant health risk in themselves. However, rigorous guidelines must be followed to avoid the physical ...

1985-08-01

333

Assessment of the sensitivity and prediction uncertainty of evaporation models applied to Nasser Lake, Egypt  

British Library Electronic Table of Contents (United Kingdom)

SummaryThis paper examines the sensitivity and uncertainty of evaporation estimates from Nasser Lake, south of Egypt using data collected at the floating station Raft, 2km upstream of the Aswan High Dam, and 12 evaporation models. Based on their approach the evaporation models were ranked in five classes, respectively the Bowen ratio energy budget (BREB) approach, three energy-aerodynamic based methods, a mass transfer method, two temperature and five solar radiation-temperature approaches. State dependent parameter models were used to estimate the sensitivity indices of the different evaporation estimation methods at daily and monthly frequencies. A drastic reduction in the cost of the sensitivity analysis was obtained when coupled with efficient sampling methods, producing quasi-Monte Ca...

2010-01-01

334

Analysis of deteriorating processes in primary circuit facilities and determination of their priorities and relevance to the lifetime of the main primary circuit components  

International Nuclear Information System (INIS)

The major degradation mechanisms acting during the aging of selected WWER-440/213 primary circuit facilities were assessed critically. The analysis gave evidence that such mechanisms include radiation and fatigue damage of the reactor pressure vessel (effect of the neutron flow, cyclic fatigue promoted by the corrosive medium, effect of thermal aging), corrosion-mechanical and thermo-mechanical (fatigue) damage of the steam generator (stress corrosion cracking, erosion corrosion, thermal aging, wear), thermal and dynamic aging of the pressurizer, and corrosion-mechanical damage of the primary circuit piping (thermal aging, corrosion). (J.B.). 5 tabs., 1 fig., 62 refs.

335

Light Infantry Division Assessment  

Science.gov (United States)

... LIGHT INFANTRY DIVISION ASSESSMENT LOl 0 BY ... TYPE OF REPORT & PERIOD COVERED LIGHT INFANTRY DIVISION ASSESSMENT ...

1990-04-02

336

Individual Radiation Protection Monitoring in the Marshall Islands: Rongelap Atoll (2002-2004)  

Energy Technology Data Exchange (ETDEWEB)

The United States Department of Energy (U.S. DOE) has recently implemented a series of strategic initiatives to address long-term radiological surveillance needs at former U.S. nuclear test sites in the Marshall Islands. The plan is to engage local atoll communities in developing shared responsibilities for implementing radiation protection monitoring programs for resettled and resettling populations in the northern Marshall Islands. Using the pooled resources of the U.S. DOE and local atoll governments, individual radiological surveillance programs have been developed in whole body counting and plutonium urinalysis in order to accurately assess radiation doses resulting from the ingestion and uptake of fallout radionuclides contained in locally grown foods. Permanent whole body counting facilities have been established at three separate locations in the Marshall Islands including Rongelap Atoll (Figure 1). These facilities ...

2006-01-17

337

Measurement of the charge asymmetry in top-antitop quark production with the CDF II experiment  

Energy Technology Data Exchange (ETDEWEB)

The Fermi National Laboratory (Fermilab) operates the Tevatron proton-antiproton collider at a center-of-mass energy of {radical}s = 1.96 TeV, the is therefore the only collider which is today able to produce the heaviest known particle, the top quark. The top quark was discovered at the Tevatron by the CDF and D0 collaborations in 1995. At the Tevatron, most top quarks are produced via the strong interaction, whereby quark-antiquark annihilation dominates with 85%, and gluon fusion contributes with 15%. Considering next-to-leading order (NLO) contributions in the cross section of top-antitop quark production, leads to a slight positive asymmetry in the differential distribution of the production angle {alpha} of the top quarks. This asymmetry is due to the interference of certain NLO contributions. The charge asymmetry A in the cosine of {alpha} is predicted [14] to amount to 4-6%. Information about the partonic rest frame, necessary for a measurement of A in the observable cos ...

2006-12-01

338

Accuracy of two heterogeneity dose calculation algorithms for IMRT in treatment plans designed using an anthropomorphic thorax phantom  

International Nuclear Information System (INIS)

With the advent of intensity-modulated radiation therapy (IMRT), the inclusion of heterogeneity corrections is further complicated by the conformal delivery of many small beams forming steep dose gradients. Radiation treatment planning has evolved to take into account even small changes in tissue density so that the dose to tumor can be further optimized. However, different treatment planning systems incorporate different heterogeneity correction algorithms, and it is unclear whether any of these algorithms are superior to others in terms of accurately predicting delivered radiation doses relative to measurement in a clinical setting. The purpose of this study was to determine the accuracy of heterogeneity dose calculations from two widely used IMRT treatment planning systems (Pinnacle and Corvus) against measurement. These two systems handle heterogeneity dose corrections by means of a collapsed-cone convolution ...

2007-05-01

339

Six orders of magnitude dynamic range in capillary electrophoresis with ultrasensitive laser-induced fluorescence detection  

UK PubMed Central (United Kingdom)

An ultrasensitive laser-induced fluorescence detector was used with capillary electrophoresis for the study of 5-carboxy-tetramethylrhodamine. The raw signal from the detector provided roughly...Full Text Available

2009-12-15

340

Focal plane detector for reactions with medium weight projectiles  

Energy Technology Data Exchange (ETDEWEB)

A new focal plane detector for an Enge split pole spectrograph has been developed which is able to resolve individual elements and isotopes up to the mass 100 region. It consists of a 60 cm long position sensitive parallel plate avalanche counter backed by a large Bragg curve detector. Compared with other position sensitive focal plane counters the new detector system has a very good time resolution (less than 300 ps) and can be operated at much higher counting rates (up to 25 kHz). The intrinsic resolution of the position detector is less than 1 mm. In addition to the energy and the nuclear charge signal obtained from the Bragg curve detector the angle of incidence into the detector can be measured with an accuracy of better than 1/sup 0/. The detector has already been used in a variety of experiments where good timing, counting rate ...

1988-12-01

341

Developments of heavy-ion gas detectors at LNL  

Energy Technology Data Exchange (ETDEWEB)

The most important developments in gaseous detectors at LNL are reviewed. Some aspects of timing, pulse height and position resolutions of avalanche counters are reported. The experimental work on heavy-ion identification by Bragg curve spectroscopy is summarized.

1984-05-01

342

Conventional detectors for a photon-photon collider  

Energy Technology Data Exchange (ETDEWEB)

Detectors for a photon-photon collider are envisaged using as guide-lines the physics goals and the interaction point environment. Production of SUSY Higgs scalar and pseudo-scalar is emphasized. Some aspects of the interaction point environment are discussed. ((orig.)).

1995-02-01

343

Comparison of Detector Intrinsic Spatial Resolution Characteristics for Sensor on the Entrance Surface and Conventional Readout Designs  

UK PubMed Central (United Kingdom)

We report on a high resolution, monolithic crystal PET detector design concept that provides depth of interaction (DOI) positioning within the crystal. Our design utilizes a novel sensor on...Full Text Available

2010-01-01

344

UNFBENJ: on-line, real-time neutron spectrum unfolding for Benjamin detectors  

International Nuclear Information System (INIS)

(Jun 1978). United States Miller, H. Univ. of Missouri, Columbia Peterman,

1978-06-18

345

The virtual fast-ion loss detector  

International Nuclear Information System (INIS)

English 2009 p. 79 Ukraine Brudgam, M. Lauber, Ph. Garcia Munoz, M.

2009-09-21

346

Radionuclide X-ray fluorescence analysis using semiconductor detectors  

International Nuclear Information System (INIS)

Czech May 1979. p. 32-33. Czechoslovakia Benada, J. Spacek, B. Ustav

1979-05-01

347

Parameter optimization of a planar BEGe detector using Monte Carlo simulations  

International Nuclear Information System (INIS)

This work reports on the use of three state-of-the-art Monte Carlo codes (MCNPX, PENELOPE, FLUKA) in the efficiency calibration of a Broad-Energy Germanium (BEGe) detector. Initial discrepancies found between the experimental and computational efficiency values are related to the poor knowledge of some physical parameters of the detector (dead-layers, crystal dimensions, etc.). As a consequence, a sensitivity analysis was carried out. Each parameter was systematically analyzed, and an accurate model of the detector was determined. The obtained results are consistent, allowing this model to be used in computational efficiency calibrations of the equipment at stake.

2010-11-21

348

Method and system for detecting explosives  

Energy Technology Data Exchange (ETDEWEB)

A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

2009-03-10

349

GCR-induced Photon Luminescence of the Moon: The Moon as a CR Detector  

Science.gov (United States)

We report on the results of a preliminary study of the GCR-induced photon luminescence of the Moon

2007-01-01

350

Explosives detection system and method  

Energy Technology Data Exchange (ETDEWEB)

A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

2007-12-11

352

CMS Silicon Strip Tracker Performance  

CERN Document Server

In this paper we describe the reconstruction strategies, the calibration procedures and the detector performance results from the latest CMS operation.

2011-01-01

353

Advances in imaging THGEM-based detectors  

International Nuclear Information System (INIS)

We report on recent measurements with Thick GEM-like (THGEM)-based imaging detectors. The THGEM is a robust gaseous electron multiplier similar to GEM but with larger dimensions. It has high electron multiplication, of 105 and 107 in single- and double-THGEM structure, respectively, fast signals and ?10MHz/mm2 counting rate capability. It can be produced in any shape and over large area. In view of many possible applications of THGEM-based imaging detectors, in particle physics and beyond, we have recently studied the localization properties of a 2D 10x10cm2 detector. The results of these studies are presented.

2007-03-01

354

A new technique for radon measurement based on a combination of a track-etch detector and activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

A new technique for radon measurement in the natural environment was investigated. It is based on the use of activated charcoal and a track-etch detector. The charcoal acts as a radon collector from the air and the track-etch detector as a recorder of the alpha particles emitted by radon and its decay products. Our preliminary results show that the response of the new dosimeter to radon, using Deodorant activated charcoal (TOK, Yugoslavia) and a CR-39 track-etch detector, is 1.4 tracks cm{sup -2}/Bqm{sup -3}d, which is about eight times higher than that obtained with a standard track-etch dosimeter. (author).

1991-01-01

355

Statistical cut-off criterion  

International Nuclear Information System (INIS)

... radiation effects human populations low dose irradiation neoplasms radiation

1980-01-01

356

Radiation protection and the management of radioactive waste in the oil and gas industry  

CERN Document Server

Radiation protection and the management of radioactive waste in the oil and gas industry

2003-01-01

358

Higher harmonics of spontaneous radiation of ultrarelativistic channeled particles  

International Nuclear Information System (INIS)

The case of spontaneous radiation of channeled ultrarelativistic particles is considered when the dipolarity condition is not satisfied. The change of the particle longitudinal velocity affecting the maximum radiation frequency is included. The angular and frequency characteristics of the radiation for superhigh energies are studied for the first time. It is shown that there is an optimum energy at which the radiation density is maximum. The influence of the angle at which electrons enter a crystal and of the beam divergence on the radiation is investigated. The problem of quasichanneled particle radiation and also the radiation in axis-plane transitions are considered. (author).

1980-06-01

360

Contribution to the radiation preparation of wood-plastic materials. Pt. 7  

International Nuclear Information System (INIS)

... odd nuclei organic compounds radiation effects radioisotopes synthesis

1974-01-01

361

Contribution to the radiation preparation of wood-plastic materials. Pt. 6  

International Nuclear Information System (INIS)

... compounds polymers polyolefins polyvinyls radiation effects SYNTHESIS.

1974-01-01

362

Contribution to the radiation preparation of wood-plastic materials Pt. 3  

International Nuclear Information System (INIS)

... compounds plants radiation effects radioisotopes reaction kinetics trees

1974-01-01

363

Compact Proton and Carbon Ion Synchrotrons for Radiation Therapy  

CERN Document Server

Compact Proton and Carbon Ion Synchrotrons for Radiation Therapy

2002-01-01

364

? j -  

Science.gov (United States)

duced and spontaneous radiation. The amount of polarization is ... of the induced and spontaneous radiation patterns. Therefore ...

365

Using neutron-activation detectors with fissionable nuclides  

Energy Technology Data Exchange (ETDEWEB)

Presented are results of a test of a method for measuring neutron fluences using detectors with fissionable nuclides. The investigations show the soundness of of using neutron-activation detectors of the type Am for mesurements in nuclear installations for values of thermal-neutron fluence of from 10/sup 13/ to 10/sup 20/ neutrons/cm/sup 2/ with exposure for up to several months. The proposed method can be used for prolonged measurements in strong fields of both thermal and fast neutrons.

1986-09-01

366

Position detector design using an electrostatic application of ANSYS[sup TM  

Energy Technology Data Exchange (ETDEWEB)

The design of beam position monitor (BPM) stripline detectors has been enhanced by using the finite element code ANSYS[sup TM]. Available from Swanson Engineering, ANSYS[sup TM] was developed to solve Poisson's equation in stress and thermal analysis applications. The code is readily adaptable to solving electrostatic problems. The designs of several beam detectors were iterated by calculating electrode capacitances and characteristic impedances to better than 1% accuracy.

1994-10-10

367

Performance of CDF calorimeter simulation for Tevatron Run II  

Energy Technology Data Exchange (ETDEWEB)

The upgraded CDF II detector has collected first data during the initial operation of the Tevatron accelerator in Run II. The simulation of the CDF electromagnetic and hadronic central and upgraded plug (forward) calorimeter is based on the Gflash calorimeter parameterization package used within the GEANT based detector simulation of the Run II CDF detector. We present the results of tuning the central and plug calorimeter response to test beam data.

2002-09-19

368

Fundamental understanding of aging processes Review of the workshop results  

CERN Document Server

A study on the aging process of gas detectors was presented. How the development of more performing but delicate detectors, the use of faster but aggressive gases, and the need to cover large areas, led to unexpected problems was discussed. Various methods for curing aged detectors were also highlighted. (Edited abstract) 37 Refs.

2003-01-01

369

Bragg curve spectroscopy in a 4? geometry  

Science.gov (United States)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4? geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon.

1991-02-01

370

Bragg curve spectroscopy in a 4. pi. geometry  

Energy Technology Data Exchange (ETDEWEB)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4{pi} geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).

1991-02-01

371

Bragg curve spectroscopy in a 4#pi# geometry  

International Nuclear Information System (INIS)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4#pi# geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).

372

A comparison of x-ray detectors for mouse CT imaging  

International Nuclear Information System (INIS)

There is significant interest in using computed tomography (CT) for in vivo imaging applications in mouse models of disease. Most commercially available mouse x-ray CT scanners utilize a charge-coupled device (CCD) detector coupled via fibre optic taper to a phosphor screen. However, there has been little research to determine if this is the optimum detector for the specific task of in vivo mouse imaging. To investigate this issue, we have evaluated four detectors, including an amorphous selenium (a-Se) detector, an amorphous silicon (a-Si) detector with a gadolinium oxysulphide (GOS) screen, a CCD with a 3:1 fibre taper and a GOS screen, and a CCD with a 2:1 fibre taper and both GOS and thallium-doped caesium iodide (CsI:Tl) screens. The detectors were evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), detective quantum ...

2004-12-07

373

Sequence analysis of the ATM gene in 20 patients with RTOG grade 3 or 4 acute and/or late tissue radiation side effects  

International Nuclear Information System (INIS)

Purpose: Patients with ataxia-telangiectasia (A-T) show greatly increased radiation sensitivity and cancer predisposition. Family studies imply that the otherwise clinically silent heterozygotes of this autosomal recessive disease run a 3.5 to 3.8 higher risk of developing cancer. In vitro studies suggest moderately increased cellular radiation sensitivity of A-T carriers. They may also show elevated clinical radiosensitivity. We retrospectively examined patients who presented with severe adverse reactions during or after standard radiation treatment for mutations in the gene responsible for A-T, ATM, considering a potential means of future identification of radiosensitive individuals prospectively to adjust dosage schedules. Material and Methods: We selected 20 cancer patients (breast, 11; rectum, 2; ENT, 2; bladder, 1; prostate, 1; anus, 1; astrocytoma, 1; Hodgkins lymphoma, 1) with Grade 3 to 4 (RTOG) acute and/or late ...

1999-07-15

374

Proceedings of a specialist meeting on regulatory approaches for the control of environmental residues containing naturally occurring radioactive material. Working material  

International Nuclear Information System (INIS)

Naturally occurring radionuclides are present in most material. The most common naturally occurring radionuclides in material are those of the uranium and thorium series and potassium-40. This material is commonly referred to as Naturally Occurring Radioactive Material (NORM). In some material the levels of naturally occurring radionuclides are significantly higher, to the extent that regulatory control may be required for radiation protection purposes. Regulation of NORM presents a range of new challenges for both regulators and operators. Unlike more traditional industries dealing with radionuclides, NORM industries have generally not had any radiological oversight and, for example, are not equipped for radiological monitoring. Some consumer goods containing NORM, which have not traditionally been considered as a radiological problem (such as some fertilizers), may require regulation and this may have social and economic consequences. The transport and disposal ...

2002-09-23

375

Adaptive Waveform Correlation Detectors for Arrays: Algorithms for Autonomous Calibration  

Energy Technology Data Exchange (ETDEWEB)

Waveform correlation detectors compare a signal template with successive windows of a continuous data stream and report a detection when the correlation coefficient, or some comparable detection statistic, exceeds a specified threshold. Since correlation detectors exploit the fine structure of the full waveform, they are exquisitely sensitive when compared to power (STA/LTA) detectors. The drawback of correlation detectors is that they require complete knowledge of the signal to be detected, which limits such methods to instances of seismicity in which a very similar signal has already been observed by every station used. Such instances include earthquake swarms, aftershock sequences, repeating industrial seismicity, and many other forms of controlled explosions. The reduction in the detection threshold is even greater when the techniques are applied to arrays since stacking can be performed on the ...

2009-07-23

376

`Electric smog` - non-ionizing electromagnetic fields and radiation. Seminar of the Zentrale Informationsstelle, Umweltberatung Bayern. Vol. 1; Elektrosmog. Seminar der Zentralen Informationsstelle, Umweltberatung Bayern. Bd. 1  

Energy Technology Data Exchange (ETDEWEB)

This seminar on the subject of ``electrical smog`` welcomed participants from Bavarian environmental consultancy agencies, rural and urban district authorities, ministries, consume-consultancy agencies and public health authorities. Leading scientists from research and authorities gave papers on the sources, exposure and effects/actions of electromagnetic fields and present the current state of knowledge about the hazards and risk of this radiation for human health. The proceedings in hand provide the papers given on the following topics: electromagnetic fields - and introduction to relevant issues; low-frequency fields - sources and exposure; high-frequency fields - sources and exposure; biological actions and effects of low-frequency fields; biological actions and effects of high-frequency fields; low-frequency fields - helath risk assessment; high-frequency fields - health risk assessment. (Uhe) [Deutsch] Das Seminar zum ...

1993-06-01

377

Radiation testing of organic ion exchange resins  

International Nuclear Information System (INIS)

A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of "1"3"7Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the exchangers were irradiated ...

1983-04-11

378

Radiation testing of organic ion exchange resins  

Energy Technology Data Exchange (ETDEWEB)

A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of {sup 137}Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the exchangers were irradiated ...

1995-09-01

379

Acceleration of the development of benzopyrene-induced skin cancer in mice by microwave radiation  

Energy Technology Data Exchange (ETDEWEB)

In the present study Balb/c mice were exposed to 3,4-benzopyrene, painted on the skin every 2nd day for a total of 6 months, and simultaneously irradiated with athermal (5 mW/cm/sup 2/) or subthermal (15 mW/cm/sup 2/) doses of 2,450 MHz microwaves. The other group of animals was preirradiated with microwaves at 10 mW/cm/sup 2/ power level for 1, 2, or 3 months and then treated with benzopyrene, as above. Control mice were exposed for 6 months to benzopyrene, resulting in the development of baso- or spinocellular skin carcinoma within approximately 9 months, and sham-irradiated with microwaves. The growth of the tumour was assessed according to a self-designed 7-range macroscopic scale, supported by microscopical examinations of skin sections. All protocols of microwave irradiations resulted in a significant acceleration of the development of benzopyrene-induced skin cancer and in shortening of life span of the tumour-bearing hosts. This effect seemed to be ...

1982-12-01

380

Systematics of average radiative width of heavy nuclides  

Energy Technology Data Exchange (ETDEWEB)

Systematics of neutron capture radiative width were studied in the target element range from Th to Cm. Reduced radiative widths were analyzed with a simple radiative width formula based on E1 transition. Average radiative width is presented with the standard deviation of 15%. (author)

1999-03-01

381

Development and operational experience of traveling in core probe drive for flux scan of 540 MWe PHWR of Tarapur  

International Nuclear Information System (INIS)

TAPP-3 and 4 reactors use large number of Self Powered Neutron Detectors (SPNDs) for Neutronic lower measurement and control. To perform in-situ calibration of these detectors in select locations and to validate the reactor physics codes which predict flux at various points in the core, traveling in-core probes (TIP) are required. The TIP assembly consists of a miniature neutron sensitive detector. The detector is driven in and out of core using a mechanism which facilitates positioning of the detector anywhere inside a vertical tube (Central carrier tube of any of the six select Vertical Flux Units) in the core. TIP is driven through retractable feed mechanism for a stroke of 13 m. This paper describes the developmental efforts and the operational feedback of the retractable feed mechanism for the stroke of 13 m used at TAPP 3 and 4 reactor. (author)

2006-11-13

382

Calibration of solid state nuclear track detector CR-39 for radon measurements  

Energy Technology Data Exchange (ETDEWEB)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

2007-07-01

383

Calibration of solid state nuclear track detector CR-39 for radon measurements  

International Nuclear Information System (INIS)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

384

A method to study heavy ion reactions using position sensitive and Bragg curve spectroscopy detectors  

Energy Technology Data Exchange (ETDEWEB)

A large area Bragg curve spectroscopy (BCS) detector and a position sensitive parallel grid avalanche counter have been developed to study heavy ion reactions, such as inelastic excitations and few nucleon transfer reactions near the Coulomb barrier. Reasonably good resolutions have been achieved for energy, atomic number and angle. A theoretical investigation on the mass dependence of the Bragg peak signal from the BCS detector, shows that there is a negligible mass dependence related to the geometry of the detector. The mass number of the heavy ions which cannot be obtained by the above method, has been identified by detecting the corresponding characteristic gamma rays from the product nuclei with two large solid angle gamma ray detectors. (orig.)

1993-10-15

385

A method to study heavy ion reactions using position sensitive and Bragg curve spectroscopy detectors  

International Nuclear Information System (INIS)

A large area Bragg curve spectroscopy (BCS) detector and a position sensitive parallel grid avalanche counter have been developed to study heavy ion reactions, such as inelastic excitations and few nucleon transfer reactions near the Coulomb barrier. Reasonably good resolutions have been achieved for energy, atomic number and angle. A theoretical investigation on the mass dependence of the Bragg peak signal from the BCS detector, shows that there is a negligible mass dependence related to the geometry of the detector. The mass number of the heavy ions which cannot be obtained by the above method, has been identified by detecting the corresponding characteristic gamma rays from the product nuclei with two large solid angle gamma ray detectors. (orig.).

386

A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements  

Energy Technology Data Exchange (ETDEWEB)

A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with ...

1991-09-01

387

A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements  

International Nuclear Information System (INIS)

A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with ...

388

A Detector for 2-D Neutron Imaging for the Spallation Neutron Source  

Energy Technology Data Exchange (ETDEWEB)

Abstract - We have designed, built, and tested a 2-D pixellated thermal neutron detector. The detector is modeled after the MicroMegas-type structure previously published for collider-type experiments. The detector consists of a 4X4 square array of 1 cm 2 pixels each of which is connected to an individual preamplifier-shaper-data acquisition system. The neutron converter is a 10B film on an aluminum substrate. We describe the construction of the detector and the test results utilizing 252Cf sources in Lucite to thermalize the neutrons.Drift electrode (Aluminum) Converter (10B) 3 mm Conversion gap neutron (-900 V)

2006-07-01

389

Retrospective individual dosimetry using luminescence and EPR after radiation accidents  

International Nuclear Information System (INIS)

In areas where radiation dose monitoring has not been performed, it is essential to use material available in the environment be able to rapidly assess doses to individuals for immediate emergency medical care or for general estimation of the radiological consequences. It was shown that certain types of telephone cards containing microchips have the potential to be used as individual radiation dosimeters in emergency situations to detect doses over 250 mGy by luminescence measurements. In order to understand the dosimetric properties of chip cards, the components obtained from INFINIEON Company at various stages of production were used for luminescence measurements. It is found that the protecting layer used above the chips so called 'globe top' is the main source of radiation induced signal in chip cards. The globe top produced by INFINIEON at that stage is found to contain SiO2 and Epoxy. In order to ...

390

Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart  

Energy Technology Data Exchange (ETDEWEB)

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A{sub 1}) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs{sub eff}). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A{sub 2}). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was applied. The data of all groups were evaluated ...

2003-12-01

391

Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart  

International Nuclear Information System (INIS)

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A_1) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs_e_f_f). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A_2). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was applied. The data of all groups were evaluated by a ...

2003-12-01

392

Hyperfractionated radiation therapy for incompletely resected supratentorial low-grade glioma. A phase II study  

International Nuclear Information System (INIS)

Background and purpose: In order to investigate the feasibility, toxicity and antitumor efficacy of hyperfractionated radiation therapy, 37 adult patients with incompletely resected supratentorial low-grade glioma were entered into a phase II study. Materials and methods: The radiation therapy dose was 55 Gy in 50 fractions in 25 treatment days over 5 weeks to the tumor plus a 2-cm margin, with an additional 17.6 Gy given in 16 fractions in 8 treatment days over 1.5 weeks to the tumor plus a 1-cm margin, using 1.1 Gy b.i.d. fractionation with a 6 h interfraction interval. The total tumor dose was 72.6 Gy in 66 fractions in 33 treatment days over 6.5 weeks. Results: The median survival time (MST) for all 37 patients has not yet been attained, while 5- and 7-year survival rates were 75% and 69%, respectively. The median time to tumor progression (MTP) has also not yet been attained, while 5- and 7-year progression-free survival (PFS) rates were ...

1998-10-01

393

Exposure to radiation from the natural radioactivity in building materials  

International Nuclear Information System (INIS)

Radiation exposure of members of the public can be increased appreciably by the use of building materials containing above-normal levels of natural radioactivity. This phenomenon has attracted attention in recent years, and in this review, an attempt is made to the quantify exposures incurred under various circumstances. The second section of the review is a general survey of those building materials, mostly industrial wastes, that have aroused interest in Member countries. The probability that environmental pressures may cause such wastes to be used more and more by building industries may lead to similar situations in the future. Other review material of a relevant nature is described in the third section. Primordial radionuclides only are considered here. They are: potassium-40 (K-40); radium-226 (Ra-226) and its decay products; the series headed by thorium-232 (Th-232). The important radiological consequences of the natural radioactivity in building materials ...

2010-05-01

394

Dose and temporary characteristics of the changes in the amount of nucleic acids in leucocytes of irradiated rats  

International Nuclear Information System (INIS)

An attempt was made for early quantitative assessment of the severety of an injury, using the nuclear acids (NA) content as a biochemical indicator. Sexually mature male rats with body mass 160-180 g were irradiated with doses 0.5, 1, 2, 4 and 8 Gy of "1"3"7Cs source. Uneven irradiation was achieved by shielding the abdominal-lumbar area with lead rings, measuring 2,5/50 mm. A 28-30% fall of the dose beneath the shielded zone was thus provided. Dose-dependent quantitative changes in Na content were determined on hours 24 and 72 within the range from 0.5 to 8 Gy and followed up until day 30 after irradiation with nonlethal (2 Gy) and lethal (8 Gy) doses. The total NA content in the leucocytes was determined by the method of Kritski and Aleksandrov. The uneven irradiation of rats within the 0,5-8 Gy range induced early dose-dependent changes in NA content. The nature of their post-irradiation dynamics also depended on the radiation dose and ...

395

Using the /phi/resund experimental data to evaluate the ARAC emergency response models  

Energy Technology Data Exchange (ETDEWEB)

A series of meteorological and tracer experiments, was conducted during May and June 1984 over the 20-km wide /O/resund strait between Denmark and Sweden for the purpose of studying atmospheric dispersion processes over cold water and warm land surfaces and providing the data needed to evaluate meso-scale models in a coastal environment. In concert with these objectives the data from these experiments have been used as part of a continuing effort to evaluate the capability of the three-dimensional MATHEW/ADPIC (M/A) atmospheric dispersion models to simulate pollutant transport and diffusion characteristics of the atmospheric during a wide variety of meteorological conditions. Since previous studies have focused primarily on M/A model evaluations over rolling and complex terrain at inland sites, the /O/resund experiments provide a unique opportunity to evaluate the models in a coastal environment. The M/A models are used by the Atmospheric Release Advisory Capability (ARAC), developed ...

1988-07-01

396

Scientific Assessment of Ozone Depletion: 2002. Pursuant to Article 6 of the Montreal Protocol on Substances that Deplete the Ozone Layer  

Science.gov (United States)

Since the Scientific Assessment of Ozone Depletion: 1998, numerous laboratory investigations, atmospheric observations, and theoretical and modeling studies have produced new key findings and have strengthened overall understanding of the ozone layer and its effect on ultraviolet (UV) radiation. These advances are highlighted in the following summary of the current understanding of the impact of human activities and natural phenomena on the ozone layer and the coupling of the ozone layer and the climate system. In the troposphere (i.e., lower atmosphere), observations show that the total combined effective abundance of ozone-depleting compounds continues to decline slowly from the peak that occurred in 1992-1994. Total chlorine is declining, while bromine from industrial halons is still increasing, albeit at a slower rate than was occurring previously (and as reported in the 1998 Assessment). Analyses of air trapped in snow ...

2003-01-01

397

Phase report 1C, TA-21 operable unit RCRA Facility Investigation, Outfalls Investigation  

Energy Technology Data Exchange (ETDEWEB)

This phase report summarizes the results of field investigations conducted in 1992 at Technical Area 21 of Los Alamos National Laboratory, as prescribed by the RCRA Facility Investigation work plan for the Technical Area 21 operable unit (also known as OU 1106). This phase report is the last part of a three-part phase report describing the results of field work conducted in 1992 at this operable unit. Phase Report lA, issued on l4 June l993, summarized site geologic characterization activities. Phase report 1B, issued on 28 January 1994, included an assessment of site-wide surface soil background, airborne emissions deposition, and contamination in the locations of two former air filtration buildings. The investigations assessed in Phase Report 1C include field radiation surveys and surface and near-surface sampling to characterize potential contamination at 25 outfalls and septic systems listed as SWMUs in the RFI work ...

1994-02-28

398

Modelling and assessment of accident consequences: Development of a computer-assisted decision-support system RODOS/RESY for nuclear emergencies; Modellierung und Abschaetzung von Unfallfolgen: Entwicklung des rechnergestuetzen Entscheidungshilfesystems RODOS/RESY fuer kerntechnische Notfaelle  

Energy Technology Data Exchange (ETDEWEB)

In cooperation with NRPB, the specifications of the mainframe COSYMA version 95/1 and the PC COSYMA version 2.0 were prepared and the corresponding modifications implemented. Important improvements are dose-rate dependent models for deterministic health effects, the time dependent efficiency of stable iodine tablets, the extension of data bases for the inclusion of activation products, and supplementary evaluation programs. PC COSYMA has been completed by an economics module, further options in the ingestion pathways, and a graphics package for presenting assessment results. COSYMA has been applied for probabilistic dose assessments within paramter studies and special investigations of EPR concepts. RODOS, the real-time on-line decision support system for nuclear emergency management, has been further developed with the aim of the first pilot version 2.0 for pre-operational application in the second half of 1995. At present, some 20 institutes ...

1995-08-01

399

Neutron detector counting capabilities for /sup 10/B-lined and /sup 235/U fission chambers in high gamma-ray fluxes  

Energy Technology Data Exchange (ETDEWEB)

This report compares the performance characteristics of /sup 10/B-lined and fission-neutron detectors in gamma-ray fluxes typical of the fields to be encountered during nondestructive testing of irradiated light-water fuel assemblies stored in water. Using the optimum time constants for each of the /sup 10/B-lined detectors, the 0.25-in.-dia detector had a 5% loss in neutron count sensitivity at 7000 rad/h. Similarly, the 0.5-in.-dia detector had a 7% loss at 13,000 rad/h and the 1-in.-dia detector had a 5% loss in sensitivity at 1000 rad/h. Uranium-235 fission chambers were operated successfully in fields above 100,000 rad/h with no loss in neutron counting sensitivity. Shielding calculations were done to determine the appropriate shield thickness needed for a /sup 10/B-lined neutron detector to operate in a 50,000 rad/h field, typical of light-water-reactor ...

1985-03-01

400

Large area, low capacitance Si(Li) detectors for high rate x-ray applications  

Energy Technology Data Exchange (ETDEWEB)

Large area, single-element Si(Li) detectors have been fabricated using a novel geometry which yields detectors with reduced capacitance and hence reduced noise at short amplifier pulse-processing times. A typical device employing the new geometry with a thickness of 6 mm and an active area of 175 mm 2 has a capacitance of only 0.5 pf, compared to 2.9 pf for a conventional planar device with equivalent dimensions. These new low capacitance detectors, used in conjunction with low capacitance field effect transistors, will result in x-ray spectrometers capable of operating at very high count rates while still maintaining excellent energy resolution. The spectral response of the low capacitance detectors to a wide range of x-ray energies at 80 K is comparable to typical state-of-the-art conventional Si(Li) devices. In addition to their low capacitance, the new devices offer other advantages over ...

1992-10-01

401

Development of internal dose estimation software on radiation protection  

International Nuclear Information System (INIS)

Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)

2008-10-01

402

Studies of nuclear processes at the Triangle Universities Nuclear Laboratory. Progress report, 1 September 1995--31 August 1996  

Energy Technology Data Exchange (ETDEWEB)

The Triangle Universities Nuclear Laboratory (TUNL)--a collaboration of Duke University, North Carolina State University, and the University of North Carolina at Chapel Hill--has had a very productive year. This report covers parts of the second and third year of a three-year grant between the US Department of Energy and the three collaborating universities. The TUNL research program focuses on the following areas: precision test of parity-invariance violation in resonance neutron scattering at LANSCE/LANL; parity violation measurements using charged-particle resonances in A = 20--40 targets and the A = 4 system at TUNL; chaotic behavior in the nuclei {sup 30}P and {sup 34}Cl from studies of eigenvalue fluctuations in nuclear level schemes; search for anomalies in the level density (pairing phase transition) in 1f-2p shell nuclei using GEANIE at LANSCE/LANL; parity-conserving time-reversal noninvariance tests using {sup 166}Ho resonances at Geel, ORELA, or LANSCE/LANL; nuclear ...

1996-09-01

403

K/sub. beta. //K/sub. cap alpha. / transition probability ratios from the measurement of fluorescent X-ray intensities of some lanthanide compounds  

Energy Technology Data Exchange (ETDEWEB)

The effect that different chemical and physical atomic environments can have on the relative intensities of radiative electron transitions from the filling of K shell vacancies was investigated. The method used involved the detection of photoionization induced X-ray fluorescence. An experimental system based on a hyper pure germanium detector (HPGE) was used to measure the relative K-L and K-M X-ray yields from the photofluorescence of a series of lanthanide elements and compounds. A background subtraction and peak integration strategy was employed which accounted for scattering in the samples and scattering of the flux from the radioisotope photoionization sources. Analysis of the data resulted in a tabulation of relative K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ratios. The measured relative K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ratios were compared to the calculated values predicted by the theoretical development of ...

1987-01-01

404

K/sub #beta#//K/sub #alpha#/ transition probability ratios from the measurement of fluorescent X-ray intensities of some lanthanide compounds  

International Nuclear Information System (INIS)

The effect that different chemical and physical atomic environments can have on the relative intensities of radiative electron transitions from the filling of K shell vacancies was investigated. The method used involved the detection of photoionization induced X-ray fluorescence. An experimental system based on a hyper pure germanium detector (HPGE) was used to measure the relative K-L and K-M X-ray yields from the photofluorescence of a series of lanthanide elements and compounds. A background subtraction and peak integration strategy was employed which accounted for scattering in the samples and scattering of the flux from the radioisotope photoionization sources. Analysis of the data resulted in a tabulation of relative K/sub #beta#//K/sub #alpha#/ X-ray intensity ratios. The measured relative K/sub #beta#//K/sub #alpha#/ X-ray intensity ratios were compared to the calculated values predicted by the theoretical development of Scofield and ...

1987-01-01

405

Effect of Collimation Slit and Shield Thickness in a Prompt Gamma-based Proton Beam Range Measurement System  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has a unique advantage over the electron and photon beams in that it can give very high radiation dose to the tumor volume, while effectively sparing the neighboring healthy tissue and organs. For the clinical application of the proton beam, it is very important to confirm the location of the proton beam in the patient, preferentially during the treatment. It has been suggested that the range of the proton beam in the patient can be determined by measuring prompt gammas from the proton beam passage. Recently, a prototype prompt-gamma scanning system has been constructed and tested using experimental and therapeutic proton beams. The measurement results for the proton beams of 70 . 230 MeV showed that a clear correlation exists between the distribution of the prompt gammas and the proton beam range. The scanning method, however, is not suitable for the upcoming 'spot scanning' technique. The 'spot scanning' ...

2007-07-01

406

NWIS MEASUREMENTS FOR URANIUM METAL ANNULAR CASTINGS  

Energy Technology Data Exchange (ETDEWEB)

This report describes measurements performed with annular uranium metal castings of different enrichments to investigate the use of {sup 252}Cf-source-driven noise analysis measurements as a means to quantify the amount of special nuclear material (SNM) in the casting. This work in FY 97 was sponsored by the Oak Ridge Y-12 Plant and the DOE Office of Technology Development Programs. Previous measurements and calculational studies have shown that many of the signatures obtained from the source-driven measurement are very sensitive to fissile mass. Measurements were performed to assess the applicability of this method to standard annular uranium metal castings at the Oak Ridge Y-12 plant under verification by the International Atomic Energy Agency (IAEA) using the Nuclear Weapons Identification System (NWIS) processor. Before the measurements with different enrichments, a limited study of source-detector-casting moderator configurations was ...

1998-03-13

407

Long pulse chemical laser. Final technical report  

Energy Technology Data Exchange (ETDEWEB)

This report covers the technical effort through February, 1989. This effort was directed towards the technology associated with the development of a large scale, long pulse DF-CO{sub 2} chemical laser. Optics damage studies performed under Task 1 assessed damage thresholds for diamond-turned salt windows. Task 2 is a multi-faceted task involving the use of PHOCL-50 for laser gain measurements, LTI experiments, and detector testing by LANL personnel. To support these latter tests, PHOCL-50 was upgraded with Boeing funding to incorporate a full aperture outcoupler that increased its energy output by over a factor of 3, to a full kilojoule. The PHOCL-50 carbon block calorimeter was also recalibrated and compared with the LANL Scientech meter. Cloud clearing studies under Task 3 initially concentrated on delivering a Boeing built Cloud Simulation Facility to LANL, and currently involves design of a Cold Cloud Simulation Facility. A Boeing IRAD ...

1989-02-01

408

Final report of the second dye-tracer test at the Chesnut Ridge Security Pits, Y-12 Plant, Oak Ridge, Tennessee  

Energy Technology Data Exchange (ETDEWEB)

Martin Marietta Energy Systems, Inc. (Energy Systems) manages a closed hazardous waste disposal unit, Chestnut Ridge Security Pits (CRSP), in the form of two trenches and several auger-holes, located on top of the eastern portion of Chestnut Ridge at the Department of Energy (DOE) Oak Ridge Y-12 Plant in Tennessee. The groundwater monitoring system for the unit presently consists of a network of upgradient and downgradient monitor wells. To investigate the discharge of groundwater to springs and streams, Energy Systems, through Geraghty and Miller, Inc., conducted an initial dye-tracer study during the driest part of 1990. The dye was detected at some of the monitoring sites, but verification was necessary due to the proximity of some sites to extraneous dye sources. Based on the results of the initial study, Energy Systems recommended to the Tennessee Department of Environment and Conservation (TDEC) in the 1990 Groundwater Quality Assessment Report (GWQAR) (HSW ...

1992-11-01

409

Field test for treatment verification of an in-situ enhanced bioremediation study  

Energy Technology Data Exchange (ETDEWEB)

Due to a leakage from a 12-inch pressurized diesel steel pipe four years ago, an area of approximately 30,000 square meters was contaminated. A pilot study applying the technology of in-situ enhanced bioremediation was conducted. In the study, a field test kit and on-site monitoring equipment were applied for site characterization and treatment verification. Physically, the enhanced bioremediation study consisted of an air extraction and air supply system, and a nutrition supply network. Certain consistent sampling methodology was employed. Progress was verified by daily monitoring and monthly verification. The objective of this study was to evaluate the capabilities of indigenous microorganisms to biodegrade the petroleum hydrocarbons with provision of oxygen and nutrients. Nine extraction wells and eight air sparging wells were installed. The air sparging wells injected the air into geoformation and the extraction wells provided the underground air circulation. The soil samples were ...

1995-09-01

410

Correct diagnosis of vascular encasement and longitudinal extension of hilar cholangiocarcinoma by four-channel multidetector-row computed tomography  

International Nuclear Information System (INIS)

Accurate diagnosis of local invasion of hilar cholangiocarcinomas is challenging due to their small size and the anatomic complexity of the hepatic hilar region. On the other hand, the correct diagnosis of local invasion is essential for assuring the possibility of curative surgery. The purpose of this study was to evaluate the feasibility of four-channel multidetector-row computed tomography (MDCT) in the assessment of vascular and bile duct involvement, by which we could obtain useful information for the surgical management of hilar cholangiocarcinoma. The subjects were 18 patients for whom the extent of tumor invasion was surgically and pathologically confirmed. All patients underwent preoperative multiphasic CT scanning by MDCT. Arterial and portal dominant phases were acquired using a detector configuration of 1.25 mm x 4 mm, and both axial and multiplanar reconstructed images were interpreted. Longitudinal extension was evaluated up to ...

2009-01-01

411

A novel method to characterize the MTF in 3D for computed mammotomography  

Science.gov (United States)

A novel phantom has been developed to measure the modulation transfer function (MTF) in 3D for x-ray computed tomography. The phantom consists of three tungsten wires, positioned nearly orthogonal to each other. Simultaneous measurements of the MTF are taken at various locations along the three orthogonal reconstructed planes. Our computed mammotomography (CmT) system uses a Varian Paxscan 2520 digital x-ray detector which can be positioned anywhere in ~2pi steradian band and can have arbitrary trajectories. With a half-cone beam geometry and with the phantom positioned near the center of rotation, projection images are acquired over 360 degrees. Various 3D orbits are evaluated including vertical axis of rotation and saddle. Reconstructions were performed using an iterative ordered-subsets transmission algorithm on rebinned projection images, using various numbers of iterations. Rotation of reconstructed slices isolated each wire into its own plane. At various ...

2006-03-01

412

The evaluation of risks from radiation  

International Nuclear Information System (INIS)

German translation of the publication 'The evaluation of risks from radiation' published in 1965 by the International Commission on Radiological Protection. In a survey, genetic and somatic risks from radiation are presented and explained. (HP).

1977-01-01

414

Radionuclide X-ray fluorescence analysis. 1: Excitation of X-ray fluorescense radiation by nuclear radiation  

Science.gov (United States)

The principles of radionuclide excitation of X-ray fluorescence radiation and its application in

1972-01-01

415

Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation  

Science.gov (United States)

This investigation describes the technique for the detection of the X-ray fluorescent radiation

1972-01-01

416

Radiation protection - an overview of the concept for radiation protection at work and the concept for environmental radiation protection  

International Nuclear Information System (INIS)

This book gives an overview of the entire field of radiation protection with the subject areas radioactivity, X-rays, UV radiation, laser beams and high-frequency electromagnetic fields. It deals graphically with the most important physical notions, the incidence, origin, properties and biological effects of types of radiation, administrative and practical protection measures and the code of rules governing them. Apart from fundamentals of radiation protection the emphasis on the following: natural radiation exposure, radiation exposure to radon, disaster relief plans in the environment of nuclear plant, the precautionary radiation protection system evolved after Chernobyl, radiation exposure through UV radiation devices, radio, RF communication, radar, microwave ovens and high-voltage transmission ...

1993-01-01

417

Post-Columbia Budget Proposal: FY 2003 Supplemental FY 2004 - NASA  

Science.gov (United States)

NASA cost-risk assessment is composed of cost estimating relationship (CER) and technical risk assessment plus cost element correlation assessment; ...

418

Model for assessing psychosocial problems.  

UK PubMed Central (United Kingdom)

The Model for the Assessment of Psychosocial Problems (MAPP) can help family medicine residents effectively assess patients with psychosocial problems. Following a patient-centred clinical method, MAPP...Full Text Available

1996-02-01

421

THE ENVIRONMENTAL MANAGEMENT AND CO-ORDINATION ACT, 1999  

Wastenet

Subject to the provisions of the Radiation Protection Act, the Authority, on the advice of ...(f) in collaboration with the Radiation Protection Board, conduct an ionising radiation monitoring programme and ...or document kept under the control of the Radiation Protection Board.

428

Application of gamma radiation  

International Nuclear Information System (INIS)

Described and discussed in this paper are radiation processes and their advantages over the conventional techniques. Radiation sterilization of medical products, food irradiation, wood plastic composites, and radiation treatment of sewage and waste waters are presented. The Philippine experience in using these technologies, its problems and barriers are also given. (ELC).

1985-12-10

431

Pulse Rise Time Characterization of a High Pressure Xenon Gamma Detector for use in Resolution Enhancement  

CERN Document Server

High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics ...

2000-01-01

432

Physics of the {sup 252}Cf-source-driven noise analysis measurement  

Energy Technology Data Exchange (ETDEWEB)

The {sup 252}Cf-source-driven noise analysis method is a versatile measurements tool that has been applied to measurements for initial loading of reactors, quality assurance of reactor fuel elements, fuel processing facilities, fuel reprocessing facilities, fuel storage facilities, zero-power testing of reactors, verification of calculational methods, process monitoring, characterization of storage vaults, and nuclear weapons identification. This method`s broad range of application is due to the wide variety of time- and frequency domain signatures, each with unique properties, obtained from the measurement. The following parameters are obtained from this measurement: average detector count rates, detector multiplicities, detector autocorrelations, cross-correlation between detectors, detector autopower spectral densities, cross-power spectral densities between ...

1997-02-01

433

Electronics for the Si detectors in APEX  

Energy Technology Data Exchange (ETDEWEB)

APEX (ATLAS Positron EXperiment), a collaborative effort of ANL, FSU, MSU/NSCL, Princeton, Queen`s, Rochester, Washington and Yale, is an experiment to study positron and electron production in very heavy ion collisions. The electrons and positrons are detected with two detector arrays, each consisting of 216 1 mm thick Si PIN diodes, and their energy and time-of-flight are measured. The number of detectors and limited space made it necessary to develop a system that could efficiently process and transfer signals from the detectors to the charge sensing ADC`s and data readout electronics as well as monitor the condition of the detectors. The discussion will cover the electronics designed for the Si detectors, including the charge amplifier, ``Mother board`` for the charge amplifiers, 8 channel Shaper, 16 channel Constant Fraction Discriminator (CFD), 16 channel Peak-to-FERA (PTF) ...

1994-07-01

434

Development of Micromegas-like gaseous detectors using a pixel readout chip as collecting anode  

International Nuclear Information System (INIS)

This thesis reports on the fabrication and test of a new gaseous detector with a very large number of readout channels. This detector is intended for measuring the tracks of charged particles with an unprecedented sensitivity to single electrons of almost 100 %. It combines a metal grid for signal amplification called the Micromegas with a pixel readout chip as signal collecting anode and is dubbed GridPix. GridPix is a potential candidate for a sub-detector at a future electron linear collider (ILC) foreseen to work in parallel with the LHC around 2020--2030. The tracking capability of GridPix is best exploited if the Micromegas is integrated on the pixel chip. This integrated grid is called InGrid and is precisely fabricated by wafer post-processing. The various steps of the fabrication process and the measurements of its gain, energy resolution and ion back-flow property are reported in this document. Studies of the ...

435

Characterization of 3D thermal neutron semiconductor detectors  

International Nuclear Information System (INIS)

Neutron semiconductor detectors for neutron counting and neutron radiography have an increasing importance. Simple silicon neutron detectors are combination of a planar diode with a layer of an appropriate neutron converter such as 6LiF. These devices have limited detection efficiency of not more than 5%. The detection efficiency can be increased by creating a 3D microstructure of dips, trenches or pores in the detector and filling it with a neutron converter. The first results related to the development of such devices are presented. Silicon detectors were fabricated with pyramidal dips on the surface covered with 6LiF and then irradiated by thermal neutrons. Pulse height spectra of the energy deposited in the sensitive volume were compared with simulations. The detection efficiency of these devices was about 6.3%. Samples with different column sizes were fabricated to study the electrical properties ...

2007-06-11

436

A final report for: Gallium arsenide P-I-N detectors for high-sensitivity imaging of thermal neutrons  

Energy Technology Data Exchange (ETDEWEB)

This SBIR Phase I developed neutron detectors made from gallium arsenide (GaAs) p-type/ intrinsic/n-type (P-I-N) diodes grown by metalorganic chemical vapor deposition (MOCVD) onto semi-insulating (S1) bulk GaAs wafers. A layer of isotonically enriched boron-10 evaporated onto the front surface serves to convert incoming neutrons into lithium ions and a 1.47 MeV alpha particle which creates electron-hole pairs that are detected by the GaAs diode. Various thicknesses of ''intrinsic'' (I) undoped GaAs were tested, as was use of a back-surface field (BSF) formed from a layer of Al{sub x}Ga{sub 1-x}As. Schottky-barrier diodes formed from the same structures without the p+ GaAs top layer were tested as a comparison. After mesa etching and application of contacts, devices were tested in visible light before application of the boron coating. Internal quantum efficiency (IQE) of the best diode near the GaAs bandedge is over 90%. The ...

1999-04-01

438

Radiobiology  

International Nuclear Information System (INIS)

This text-book (electronic book - multi-media CD-ROM) constitutes a course-book - author's collection of lectures. It consists of 13 lectures in which the reader acquaints with the basis of radiobiology: Introduction to radiobiology; Physical fundamentals of radiobiology; Radiation of cells; Modification of radiation damage of cells; Reparation of radiation damage of cells; Radiation syndromes and their modification; Radiation injury; Radiation damage of tissues; Effect of radiation on embryo and fetus; Biological effects of incorporated radionuclides; Therapy of acute irradiation sickness; Delayed consequences of irradiation; Radiation oncology and radiotherapy. This course-book may be interesting for students, post-graduate students of chemistry, biology, physics, medicine as well as for teachers, scientific workers ...

439

Radiation Therapy in Treating Patients With Prostate Cancer  

Science.gov (United States)

Prostate Cancer; Psychosocial Effects of Cancer and Its Treatment; Radiation Toxicity; Sexual Dysfunction and Infertility

2011-09-13

441

NAME=\\  

Wastenet

... Radiation Protection Products and Equipment Find and compare a variety of radiation protection products and equipment on the world's largest environmental industry portal. View product ...

443

Variability of infrared stimulated luminescence properties from fractured feldspar grains  

Energy Technology Data Exchange (ETDEWEB)

A series of OSL properties of fragments from split feldspar grains have been investigated. These are (1) the response to a radiation dose, (2) the recycling of corrected induced luminescence (L{sub i}/T{sub i}), (3) the corrected natural luminescence (L{sub N}/T{sub N}), (4) the corrected thermal transfer luminescence (termed herein L{sub tt}/T{sub tt}) and, (5) the rate of anomalous fading ('g'). It was found that the parameters of different parts of the same grain are the same. The relative uncertainty, at the 2 sigma level, at which we can claim that the measured parameters are correlated, is generally less than 5% but is ca 40% for the anomalous fading rate due to measurement uncertainty. For young partially bleached sediments, the result is that one could use one fragment to evaluate the equivalent dose and another to assess the contribution of thermal transfer resulting from preheating the natural luminescence.

2003-10-01

444

Tissue Heterogeneity in IMRT Dose Calculation for Lung Cancer  

International Nuclear Information System (INIS)

The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the ? function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the lung and in the tumor area. These differences are not always in DVH of the lung, although the Wilcoxon test indicated significant differences in 2 of 4 patients. ...

2011-01-01

445

The preparation of highly absorbing cellulosic copolymers -the cellulose acetate/propionate-g. co-acrylic acid system  

Energy Technology Data Exchange (ETDEWEB)

A series of copolymers based on the cellulose acetate/propionate-g.co-acrylic acid system has been prepared under radiation-induced control. These copolymers have been assessed for their water-retention capacity both in an unmodified state and after ''decrystallization'' or ''neutralization'' treatments. The grafting of acrylic acid onto the cellulose acetate/propionate had little effect on the water retention power of the cellulose acetate/propionate. However, improvements to the water retentivity was obtained after ''decrystallization'' procedures had been carried out on the copolymers using selected alkali metal salts with methanol as the continuous medium. The water-retentivity of the copolymers increased with increase in the extent of grafting, though the effect is less pronounced at high graft levels. Neutralization of the ...

1990-01-01

446

The development of climatic scenarios for Finland  

Energy Technology Data Exchange (ETDEWEB)

One of the main objectives of the Finnish Research Programme on Climate Change (SILMU) has been to assess the possible impacts of future changes in climate due to the enhanced greenhouse effect on natural systems and human activities in Finland. In order to address this objective, it was first necessary to specify the types of climate changes to be expected in the Finnish region. Estimates of future climate are conventionally obtained using numerical models, which simulate the evolution of the future climate in response to radiative forcing due to changes in the composition of the atmosphere (i.e. of greenhouse gases and aerosols). However, there are large uncertainties in the model estimates because current knowledge and understanding of atmospheric processes remains incomplete. Since accurate predictions of climate change are not available, an alternative approach is to develop scenarios. These are plausible projections which reflect the best ...

1996-12-31

447

Study of chest portable radiography using computed radiography. Removal effect of X-ray scatter by a copper plate  

Energy Technology Data Exchange (ETDEWEB)

When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated through contrast manipulation to be equal to that obtained ...

2001-04-01

448

Study of chest portable radiography using computed radiography. Removal effect of X-ray scatter by a copper plate  

International Nuclear Information System (INIS)

When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated through contrast manipulation to be equal to that obtained by grid ...

2001-04-01

449

Sludge stabilization at the Plutonium Finishing Plant, Hanford Site, Richland, Washington  

Energy Technology Data Exchange (ETDEWEB)

This Environmental Assessment evaluates the proposed action to operate two laboratory-size muffle furnaces in glovebox HC-21C, located in the Plutonium Finishing Plant (PFP), Hanford Site, Richland, Washington. The muffle furnaces would be used to stabilize chemically reactive sludges that contain approximately 25 kilograms (55 pounds) of plutonium by heating to approximately 500 to 1000{degrees}C (900 to 1800{degrees}F). The resulting stable powder, mostly plutonium oxide with impurities, would be stored in the PFP vaults. The presence of chemically reactive plutonium-bearing sludges in the process gloveboxes poses a risk to workers from radiation exposure and limits the availability of storage space for future plant cleanup. Therefore, there is a need to stabilize the material into a form suitable for long-term storage. This proposed action would be an interim action, which would take place prior to completion of an Environmental Impact ...

1994-10-01

450

Significance of the results from probabilistic safety assessment at level 2 for off-site consequences  

Energy Technology Data Exchange (ETDEWEB)

The procedure was developed to enable STUK (Radiation and Nuclear Safety Authority) to make simplified estimates on off-site consequences based on the existing results of the PSA level 2 calculations done by e.g. power utilities. Method is based on dose calculated from each nuclide group of reactor activity inventory when the same release fraction for each group is assumed. This means that a specific new result from PSA level 2 can be categorised to find out a representative PSA level 3 result for this case. In addition a user interface including the procedure was prepared. Secondly some new insights about consequences based on the releases from PSA level 2 is expected to give better understanding of risks at prevailing increased reactor power levels. In this case only some early health effects and long-term doses were estimated without full-scope PSA level 3 approach. (orig.)

2000-07-01

451

Shellfish depuration by gamma irradiation: Final report for the period October 1, 1985-September 30, 1986  

International Nuclear Information System (INIS)

Irradiation of live bivalve molluscs is a promising new technique to reduce the public health threats of viral and bacterial pathogens in the consumption of raw shellfish. In studies conducted within the past year, live hardshelled clams and oysters were innoculated with Simian Rotavirus SA-11, Poliovirus I, and Hepatitis-A virus and treated with gamma ray ionizing radiation from University of Lowell/DOE 800,000 Curie "6"0Co source over a dose range of 0.5--10 kiloGray (50--1000 kilorad) to determine the effectiveness of the process in eliminating viral activity and thus easing the potential viral health threats associated with uncooked bivalves. Two viral strains, SA-11 and Poliovirus I, were employed as models to perfect laboratory technique and to estimate the most appropriate range of dose exposures necessary for optimal inactivation of the infectious pathogen, Hepatitis A. Post-irradiation survivorship of the oysters and quahogs was ...

452

Safety analysis report: packages. Pu oxide and Am oxide shipping cask (Packaging of fissile and other radioactive materials. Final report  

Energy Technology Data Exchange (ETDEWEB)

The PuO/sub 2/ cask or SP 5320-2 and 3 cask is designed for surface shipment of americium or plutonium. The cask design was physically tested to demonstrate that it met the criteria specified in US ERDA Manual Chapter 0529, and Chapter I, Interstate Commerce Commission. The package has been assessed for transport of up to 357 grams of plutonium (403 grams PuO/sub 2/ powder) and up to 176 grams of americium (200 grams AmO/sub 2/ powder), having a maximum decay heat of 203 watts. Criticality evaluation alone would allow the shipment as Fissile Class II but the radiation level of the cask, measured at the time of shipment, may exceed 50 mrem/h at the surface and require shipment as Fissile Class III. Sample calculations address only the more restrictive of the two materials, which in most cases is /sup 238/PuO/sub 2/.

1980-05-01

453

Renewable energy technology from underpinning physics to engineering application  

International Nuclear Information System (INIS)

The UK Energy Research Centre (UKERC) in it's submission to the DTI's 2006 Energy Review reminded us that the 'UK has abundant wind, wave and tidal resources available; its mild climate lends itself to bio-energy production, and solar radiation levels are sufficient to sustain a viable solar industry'. These technologies are at different stages of development but they all draw on basic and applied Science and Engineering. The paper will briefly review the renewable energy technologies and their potential for contributing to a sustainable energy supply. Three research topics will be highlighted that bridge the gap between the physics underpinning the energy conversion, and the engineering aspects of development and deployment; all three are highly relevant to the Government's programme on micro-generation. Two are these are taken from field of thin film photovoltaics (PV), one related to novel device development and the other to a measurement technique for ...

2008-03-01

454

Regulation of macrophage accessory cell activity by mycobacteria. I. Ia expression in normal and irradiated mice infected with Mycobacterium mycroti  

International Nuclear Information System (INIS)

CBA/Ca mice were infected by either the intravenous or intraperitoneal route with Mycobacterium microti and the subsequent changes in local macrophage populations examined. Following infection, the number of macrophages increased and they showed greater expression of both MHC Class II molecules. This response was not dependent on viability of the mycobacteria, in contrast to reports with other microorganisms such as Listeria. Studies in sublethally irradiated mice indicated that persistent antigen could give rise to a response after a period of host recovery which was radiation dose dependent. This procedure also highlighted differences in the regulation of different murine class II antigens in vivo, as seen by delayed re-expression of I-E antigens. Macrophage accessory cell function, as assessed by an in vitro T cell proliferation assay, correlated with Ia expression after fixation, but not after indomethacin treatment; this highlights the ...

455

Programmed improvements of the alternating gradient synchrotron complex at Brookhaven National Laboratory, Upton, New York. Environmental assessment  

Energy Technology Data Exchange (ETDEWEB)

The purpose and need for DOE to undertake the actions described in this document are to improve the efficiency of the Alternating Gradient Synchrotron (AGS) complex. Benefits would include optimization of the AGS scientific program, increased high-energy and nuclear physics experimentation, improved health and safety conditions for workers and users, reduced impact on the environment and the general public, energy conservation, decreased generation of hazardous and radioactive wastes, and completion of actions required to permit the AGS to be the injector to the Relativistic Heavy Ion Collider (RHIC)., Improved efficiency is defined as increasing the AGS`s capabilities to capture and accelerate the proton intensity transferred to the AGS from the AGS booster. Improved capture of beam intensity would reduce the beam losses which equate to lost scientific opportunity for study and increased potential for radiation doses to workers and the general public. The action ...

1994-03-01

456

Preliminary conceptual design of Siriu, A symmetric illumination, direct drive laser fusion reactor. Final report August 8, 1983-June 1, 1984  

International Nuclear Information System (INIS)

A critical issues study of a symmetric illumination, direct drive laser fusion reactor called SIRIUS has been conducted. In particular, the uniformity requirements for direct drive targets have been assessed and it is shown that respectable gains (more than 60) could be obtained at modest (2MJ) KrF laser energies. Previous ICF cavity designs have been examined for use in a symmetric illumination geometry and features from several designs have been combined into a dry wall cavity design with a radius of 8 meters. Neutronic and photonic analysis shows that the present SIRIUS cavity design can breed sufficient tritium (breeding ratio = 1.17) even with 32 laser ports penetrating the cavity. However, it was found that there are a few critical issues that remain to be solved before a self-consistent reactor design could be initiated. Radiation damage to final optics, thermal performance of SiC tiles on the SIRIUS cavity wall, and performance of ...

1984-01-01

457

Observations on the contributions of environmental restraints and innate stem cell ability to hematopoietic regeneration  

Energy Technology Data Exchange (ETDEWEB)

A competitive repopulation assay utilizing chromosome markers was used to assay the reconstituting potential of hematopoietic populations. The test populations consisted of tibial murine marrow locally irradiated with doses ranging from 1.5 Gy to 8.5 Gy and of marrow generated from either murine splenic or marrow stem cells. The purpose of this assay was to assess the innate proliferative potential and microenvironmental influences on the ability to repopulate. Regardless of origin, spleen repopulating ability consistently agreed with spleen colony-forming unit (CFU-s) content. Doses of radiation from 5 Gy to 8.5 Gy diminished, by a factor of 2, the ability to repopulate marrow despite maintenance of CFU-s levels. Marrow generated from splenic stem cells had one-fifth the repopulating ability of marrow derived from marrow stem cells, even though CFU-s levels were equivalent. The results imply that the splenic environment can only maintain stem ...

1988-03-01

458

Materials considerations for the National Spallation Neutron Source target  

Energy Technology Data Exchange (ETDEWEB)

The National Spallation Neutron Source (NSNS), in which neutrons are generated by bombarding a liquid mercury target with 1 GeV protons, will place extraordinary demands on materials performance. The target structural material will operate in an aggressive environment, subject to intense fluxes of high energy protons, neutrons, and other particles, while exposed to liquid mercury and to water. Components that require special consideration include the Hg liquid target container and protective shroud, beam windows, support structures, moderator containers, and beam tubes. In response to these demands a materials R and D program has been developed for the NSNS that includes: selection of materials; calculations of radiation damage; irradiations, post irradiation testing, and characterization; compatibility testing and characterization; design and implementation of a plan for monitoring of materials performance in service; and materials engineering and technical ...

1997-08-01

459

Lessons drawn from the accidents occurred in the framework of conventional external radiotherapy;Lecons tirees des accidents survenus dans le cadre de la radiotherapie externe conventionnelle  

Energy Technology Data Exchange (ETDEWEB)

This study examines some radiation accidents occurred in the past. This information has been systematically assessed to get global lessons. The experience feedback shows that the most of accidents happened in certain conditions. These conditions can be distributed in four categories: 1- perception and vigilance in occupation: accidental exposure happened by lack of vigilance in details and lack of vigilance and perception; 2- procedures: accidental exposure happened following a lack of procedures or control that were not enough complete, not enough documented or not completely implemented; 3- training and understanding: accidental exposures happened because the personnel was not enough qualified and educated, did not get the general training nor the the necessary specialized training; 4- liabilities: accidental exposures happened following lacks and ambiguity in the definition of functions of the personnel and in the hierarchy liabilities. In ...

2009-12-15

460

Kinetics of self-interstitial cluster aggregation near dislocations and their influence on hardening  

International Nuclear Information System (INIS)

Kinetic Monte Carlo (KMC) computer simulations are performed to determine the kinetics of SIA cluster 'clouds' in the vicinity of edge dislocations. The simulations include elastic interactions amongst SIA clusters, and between clusters and dislocations. Results of KMC simulations that describe the formation of 'SIA clouds' during neutron irradiation of bcc Fe and the corresponding evolution kinetics are presented, and the size and spatial distribution of SIA clusters in the cloud region are studied for a variety of neutron displacement damage dose levels. We then investigate the collective spatio-temporal dynamics of SIA clusters in the presence of internal elastic fields generated by static and mobile dislocations. The main features of the investigations are: (1) determination of the kinetics and spatial extent of defect clouds near static dislocations; (2) assessment of the influence of localized patches of SIA clouds on the pinning-depinning motion of ...

2009-08-01

461

Introduction of microbial nutrients in a nuclear fuel waste disposal vault as a result of excavation and operation activities  

International Nuclear Information System (INIS)

A nuclear fuel waste disposal vault would not likely be a sterile environment. Bacterial activity would be expected in those areas of the vault conducive to bacterial life, i.e., where effects of heat, moisture content, radiation and compaction would not prevent or severely restrict bacterial life and where suitable and sufficient nutrients would be present. An inventory of bacterial nutrients that would be emplaced 'intentionally' with vault materials (fuel waste, waste containers, buffer and backfill materials) has been made previously. This report assesses bacterial nutrients that would be added 'inadvertently' to a vault in the form of residues of materials used to excavate and operate a vault. Measurements of blasting material residues in the various water supplies, excavated broken rock (muck) and in cores drilled in old and new tunnel walls were made at AECL's Underground Research Laboratory. Results show that the largest potential ...

1987-08-27

462

Integrated model of the shallow and deep hydrothermal systems in the East Mesa area, Imperial Valley, California  

Energy Technology Data Exchange (ETDEWEB)

Geological, geophysical, thermal, petrophysical and hydrological data available for the East Mesa hydrothermal system that are pertinent to the construction of a computer model of the natural flow of heat and fluid mass within the system are assembled and correlated. A conceptual model of the full system is developed and a subregion selected for quantitative modeling. By invoking the Boussinesq approximation, valid for describing the natural flow of heat and mass in a liquid hydrothermal system, it is found practical to carry computer simulations far enough in time to ensure that steady-state conditions are obtained. Initial calculations for an axisymmetric model approximating the system demonstrate that the vertical formation permeability of the deep East Mesa system must be very low (k/sub v/ approx. 0.25 to 0.5 md). Since subsurface temperature and surface heat flow data exhibit major deviations from the axisymmetric approximation, exploratory three-dimensional calculations are ...

1982-01-01

463

Implementation of the NCRP wound model for interpretation of bioassay data for intake of radionuclides through contaminated wounds.  

Science.gov (United States)

Emergency response preparedness for radiological accidents involving wound contamination has become more important, considering the current extending tendency in the nuclear industry related to the nuclear fuel cycle. The US National Council on Radiation Protection and Measurements (NCRP) proposed a biokinetic and dosimetric model for the intake of radionuclides through contaminated wounds in 2007. The present paper describes the implementation of this NCRP wound model for the prediction of systemic behaviour of some important radioactive elements encountered in workplaces related to the nuclear industry. The NCRP wound model was linked to the current ICRP systemic model at each blood compartment and simultaneous differential equations for the content of radioactivity in each compartment and excreta were solved with the Runge-Kutta method. The results of the calculation of wound, whole-body or specific organ retention and daily urinary or faecal excretion rate of ...

2009-05-01

464

Hardness and defect structures in EC316LN austenitic alloy irradiated under a simulated spallation neutron source environment using triple ion-beams  

Energy Technology Data Exchange (ETDEWEB)

For an assessment of the future US spallation neutron source (SNS) target performance, radiation induced hardening and microstructural evolution were investigated as a function of ion dose for EC316LN stainless steel. Irradiation was carried out using 3.5 MeV Fe{sup +}, 360 keV He{sup +}, and 180 keV H{sup +} simultaneous ion-beams at 200 deg. C to simulate the damage, He and H production in the SNS target vessel wall. At low dose (< 1 dpa), the predominant defects were black dots whose number density saturated rapidly within a few dpa. This was followed by the evolution of interstitial loops whose number density saturated below 15 dpa. Although He-bubbles were not visible, severely scalloped loops suggested that the implanted He/H atoms existed in the form of small clusters. Comparison with reported neutron irradiation data showed that hardening and ductility loss occurred mostly in the black dot regime (< 1 dpa), but that good ...

2000-04-01

465

Hardness and defect structures in EC316LN austenitic alloy irradiated under a simulated spallation neutron source environment using triple ion-beams  

International Nuclear Information System (INIS)

For an assessment of the future US spallation neutron source (SNS) target performance, radiation induced hardening and microstructural evolution were investigated as a function of ion dose for EC316LN stainless steel. Irradiation was carried out using 3.5 MeV Fe"+, 360 keV He"+, and 180 keV H"+ simultaneous ion-beams at 200 deg. C to simulate the damage, He and H production in the SNS target vessel wall. At low dose (< 1 dpa), the predominant defects were black dots whose number density saturated rapidly within a few dpa. This was followed by the evolution of interstitial loops whose number density saturated below 15 dpa. Although He-bubbles were not visible, severely scalloped loops suggested that the implanted He/H atoms existed in the form of small clusters. Comparison with reported neutron irradiation data showed that hardening and ductility loss occurred mostly in the black dot regime (< 1 dpa), but that good ductility (>20% ...

2000-04-01

466

Genotoxic effects of sunlight-activated waste waters  

Energy Technology Data Exchange (ETDEWEB)

Natural sunlight induces a genotoxic response in cultured CHO cells pre-treated with shale oil retort process water. Near ultraviolet light (NUV) component of the solar spectrum is the apparent radiation responsible for photoactivation. Cultured human skin fibroblasts are acutely sensitive to the genotoxic effects of photoactivated process water. The mutagenic potential of photoactivated process water in human cells is the same as that witnessed for an equivalent killing dose of the potent skin carcinogen FUV. DNA repair processes are involved in modulating genotoxic effects of this photo-induced process. The exact magnitude of the potential health-related and environmental risks resulting from photoactivation of retort process waters and other oil shale by-products is unassessed at this time. Our demonstration that a significant rate of mutation occurs in cultured human cells exposed to high dilutions of process waters and fluences of NUV comparable to that ...

1981-01-01

467

Environmental pollutant isotope measurements and natural radioactivity assessment for North Tushki area, south western desert, Egypt  

Energy Technology Data Exchange (ETDEWEB)

Natural radioactive materials under certain conditions can reach hazardous radiological levels. The natural radionuclide ({sup 238}U, {sup 232}Th, {sup 40}K) contents of rock samples at various locations in the North Tushki area were investigated using gamma-spectrometric analysis. Estimates of the measured radionuclide content have been made for the absorbed dose rate of gamma radiation. The equivalent radium (R{sub eq}) and the external hazard index (H{sub ex}) which resulted from the natural radionuclides in soil are also calculated and tabulated. The studied samples have been collected from various rock exposures in the North Tushki area. The distribution of major oxides, U and Th were studied. It is found that the enrichment and depletion of the major oxides are mainly due to the effect of hydrothermal alteration, which caused mobility of some major oxides, which increases some elements and decreases others. It is important to mention that the study area is ...

2002-09-01

468

Dose assessment and behavior of tritium in environmental samples around Wolsong nuclear power plant.  

Science.gov (United States)

For the estimation of the dispersion trend of tritium discharged from the Wolsung nuclear power plant, the present level of tritium in environmental samples in the vicinity of the Wolsong site has been studied. On the basis of tritium concentrations in environmental samples, the effective dose due to tritium has been estimated for an individual and population within a 16 km radius from the Wolsong site. The annual effective dose of tritium to an inhabitant around the Wolsong site ranged from 0.15 microSv y-1 to 1.3 microSv y-1. The dose level was negligible and much lower than some applicable standards, i.e. the limit on exposure from nuclear fuel cycle to the general public as recommended by ICRP (1 mSv y-1) or US EPA's limit (0.25 mSv y-1). The collective dose to the total population within a 16 km radius from the site, 1.2 x 10(-2) man.Sv y-1 was much lower than 1 man.Sv y-1, an applicable criterion for the so-called "exemption" of radiation sources and ...

1999-04-01

469

Digital luminescent radiography: A substitute for conventional chest radiography?  

International Nuclear Information System (INIS)

The image quality of digital luminescent radiography (DLR) is sufficient for routine biplane chest radiography and for follow-up studies of heart size, pulmonary congestion, coin lesions, infiltrations, atelectasis, pleural effusions, and mediastinal and hilar lymph node enlargement. Chest radiography in the intensive care unit may in most cases be performed using the DLR technique. there is no need for repeat shots because of incorrect exposure, and the position of catheters, tubes, pacemakers, drains and artificial heart valves, the mediastinum, and the retrocardiac areas of the left lung are more confidently assessed on the edge-enhanced DLR films than on conventional films. Nevertheless, DLR is somewhat inferior to conventional film-screen radiography of the chest as it can demonstrate or rule out subtle pulmonary interstitial disease less confidently. There is no reduction of radiation exposure of the chest in DLR compared with modern ...

470

Computed Tomography in staging and follow-up of thoracic Hodgkin's diseases  

International Nuclear Information System (INIS)

As yet, the role of Computed Tomography (CT) as a routine imaging technique in the staging and follow-up of thoracic Hodgkin's disease has not been assessed. The authors reported the results obtained in 120 patients affected with thoracic Hodgkin's disease, staged and followed by means af chest X-rays and CT. CT better identified intrathoracic involvement of mediastinal nodes, of lung parenchyma, of pleura, and of pericarcial and chest walls in 54/120 patients (45%), with staging modifications in 18 (15%) of them only. Treatment was changed only in 12 patients (19%) where radiation therapy had been planned. The clinical value of the additional information yielded by CT was especially evident in the follow-up: CT allowed the correct evaluation of persistent/ recurrent disease in 51/117 patients (43.5%), a figure high enough to suggest the use of CT in the routive follow-up of patients affected with thoracic Hodgkin's disease.

1990-01-01

471

Assessment of dose-time-effect surfaces for somatic late effects after low dose irradiation  

International Nuclear Information System (INIS)

Awaiting new data from RERF, an attempt was made to estimate the somatic risks of low doses of radiation for members of the German public. The new estimate follows closely the approach used in deriving the values published in the NIH Radioepidemiological Tables. The lifetime risk factors thus calculated are significantly larger than the estimates presented in ICRP Report 26 and are consistent with estimates recently made in the ongoing reactor safety study of NUREG. The increase in lifetime risks is mainly due to the introduction of a new time projection model which appears to be more consistent with the epidemiological data for many late effect end points than the constant absolute risk model previously employed. Results from a study in which epidemiological data were stochastically simulated with a computer indicate that the shapes of actual dose effect curves might be significantly more influenced by pure chance than by the dose dependency of underlying ...

1988-04-01

472

The hunt for ?13 at the Daya Bay nuclear power plant  

International Nuclear Information System (INIS)

The Daya Bay reactor neutrino experiment is located at the Daya Bay nuclear power plant in Shenzhen, China. The experiment deploys eight 'identical' antineutrino detectors to measure antineutrino fluxes from six 2.9 GWth reactor cores in three underground experimental halls at different distances. The target zone of the Daya Bay detector is filled with 20 t 0.1% Gd doped LAB liquid scintillator. The baseline uncorrelated detector uncertainty is ?0.38% using current experimental techniques. Daya Bay can reach a sensitivity of sin22?13<0.01 with baseline uncertainties after 3 years of data taking.

2010-03-30

473

The cross-coupled interferometer for gravitational wave detection  

International Nuclear Information System (INIS)

The cross-coupled interferometer is a new design for interferometric gravitational wave detectors. Similar to the baseline gravitational wave detectors proposed for Advanced LIGO, it uses long-arm cavities in which the signal is generated. The signal fields are then extracted from the arm cavities with an additional cavity behind the long-arm cavities. The tuning of this signal extraction cavity and the parallel tuning of the signal recycling mirror can be used to optimize the peak frequency and the bandwidth of the detector independently. If we replace the signal recycling mirror by a small cavity, it is possible to amplify signals in two different frequency bands.

2002-04-07

474

Tests with superconducting re-entrant cavities for transducer applications in gravitational wave detectors  

International Nuclear Information System (INIS)

We studied the niobium re-entrant cavity utilized by the Australian group in the Niobe gravitational wave detector. Instead of using their non-contact re-entrant cavity, we plan to change it to a closed one to be used in the parametric transducers of the Brazilian Mario Schenberg detector. The performance of the transducer depends on some cavity parameters such as the electrical Q and the electrical coupling. We measured the resonant frequency and the loaded electrical Q as a function of the probe position in a closed niobium #approx#15 GHz cavity operating at 4.2 K.

2004-03-07

475

Sudbury neutrino detector  

International Nuclear Information System (INIS)

The proposed Sudbury Neutrino Observatory is based on a Cherenkov detector which has a total of 1000 tonne of heavy water and 1800 tonne of light water for its sensitive volume. The detector is optimized for the measurement of extra-terrestrial low energy electron neutrinos and electron antineutrinos spectra as well as the total neutrino flux independent of neutrino flavours. It will delineate the Standard Solar Model and neutrino propagation aspects of the solar neutrino problem, provide detailed information on the dynamics of stellar collapse and measure neutrino masses and oscillation parameters with high sensitivity.

476

Studies of a Poenitz-type black neutron detector as a neutron flux monitor  

Energy Technology Data Exchange (ETDEWEB)

A black neutron detector of novel design has been constructed and tested as a neutron flux monitor. The neutron time-of-flight (TOF) technique was used to measure the zero degree neutron spectrum from a subnanosecond pulsed proton beam on a thick metallic lithium target. We describe the detector, discuss the shielding arrangement and electronics, determine the low-energy cut-off. We calculate the efficiency, show spectra and compare measured zero degree differential cross-section of the {sup 7}Li(p, n{sub 0}){sup 7}Be reaction with recommended published cross-sections. (orig.).

1997-04-01

477

A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection  

Energy Technology Data Exchange (ETDEWEB)

A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

1991-05-01

478

A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection  

International Nuclear Information System (INIS)

A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

479

A PDA-Based ECG Beat Detector for Home Cardiac Care.  

Science.gov (United States)

Recent rapid growth in mobile computing technologies enables telemedicine applications to operate on mobile devices. Our focus is on the design of an integrated electrocardiogram (ECG) beat detector on a Personal Digital Assistant (PDA) platform for the health screening process. The ECG beat detector module will be supported by the PDA version of Personal Health Information Management System (PHIMS) and Facilitated Accurate Referral Management System (FARMS) through wireless network infrastructure as a home-based mobile cardiac monitoring solution. PMID:17282192

2005-01-01

480

Standards and guidances for limiting ionizing radiation exposure  

Energy Technology Data Exchange (ETDEWEB)

This chapter is concerned with standards and guidances for limiting radiation exposures. It is divided into three sections, each of which has several parts. Section 1: Ionizing Radiation -- Standards and Guidances Applicable to the Public: Part A, Radiation Protection Standards; Part B, Environmental Radiation Standards; Part C, Exempt Levels of Radioactivity; Part D, Protective Action Guides for Accidents. Section 2: Ionizing Radiation -- Standards Applicable to the Workplace. Section 3: Medical and Other Standards.

1992-12-31

481

Radiation protection in the operating room  

International Nuclear Information System (INIS)

On the basis of legally provided area dose measurements and time records of fluoroscopic examinations during the operation, radiation doses to medical personnel and patients are evaluated. Adequate radiation protection measures and a careful behaviour in the operating room keep the radiation exposure to the personnel below the maximum permissible exposure. Taking into account the continuous personnel radiation monitoring and medical supervision, radiation hazards in the operating room can be considered low.

482

Three-Dimensional Rotational Angiography of the Inferior Vena Cava as an Adjunct to Inferior Vena Cava Filter Retrieval  

International Nuclear Information System (INIS)

The objective of this study was to explore the role of three-dimensional (3-D) rotational angiography (RA) of the inferior vena cava (IVC; 3-D CV) before filter retrieval and its impact on treatment planning compared with standard anteroposterior cavography (sCV). Thirty patients underwent sCV and 3-D CV before IVC filter retrieval. Parameters assessed were: projection of filter arms or legs beyond the caval lumen, thrombus burden within the filter and IVC, and orientation of the filter within IVC. Skin and effective radiation doses were calculated. Statistical analysis was performed using paired Student t test and nonparametric McNemar's test. Standard anteroposterior cavography detected 49 filter arms or legs projecting beyond the caval lumen in 25 patients. Three-dimensional CV demonstrated 89 filter arms or legs projecting beyond the caval lumen in 28 patients. Twenty-two patients had additional filter arms or legs projecting beyond the ...

2009-01-01

487

Studies of relativistic heavy ion collisions at the AGS (Experiment 814)  

Energy Technology Data Exchange (ETDEWEB)

This report discusses the experimental setup of experiment 814 at Brookhaven AGS. This experiment involves the collision of silicon ions with target nuclei. The detector systems are discussed primarily. (LSP)

1990-01-01

488

Screening Samples with a Position-Sensitive Detection System Providing Isotope-Specific Information  

International Nuclear Information System (INIS)

The properties of individual radioactive particles present in a sample, such as a swipe, are more interesting than bulk properties of the sample. The present work focuses on instrumentation that provides position-sensitive spectral information non-destructively from the sample. The experimental part of the work was realized using a device called PANDA (Particles And Non-Destructive Analysis). The detector setup used in the study contains a broad-energy HPGe gamma-ray detector and a position-sensitive alpha detector. Both detectors are connected to a time-stamping event-mode data acquisition system. The method is shown to locate particles with sub-millimetre accuracy and distinguish the interesting particles from non-interesting ones. (author)

2010-11-01

489

Radon concentration measurements by means of nuclear tracks detector with image analysis  

International Nuclear Information System (INIS)

English 1998 p. 124 Poland Antanasijevic, R. Vukovic, J. Novakovic, V. Tasic,

1998-09-15

490

Photoconductive ultraviolet detectors based on ZnO films  

British Library Electronic Table of Contents (United Kingdom)

Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8mA, and a slow photoresponse with a rise time of 5min and a decay time of 7min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the d...

2006-01-01

491

Intercomparison of Retrospective Radon Detectors  

Energy Technology Data Exchange (ETDEWEB)

We performed both a laboratory and field intercomparison of two novel glass-based retrospective radon detectors previously used in major radon case-control studies performed in Missouri and Iowa. The new detectors estimate retrospective residential radon exposure from the accumulation of a long-lived radon decay product, Pb-210, in glass. The detectors use track registration material in direct contact with glass surfaces to measure the alpha emission of a Pb-210 decay product, Po-210. The detector's track density generation rate (tracks cm{sup -2} hr{sup -1}) is proportional to the surface alpha activity. In the absence of other strong sources of alpha emission in the glass, the implanted surface alpha activity should be proportional to the accumulated Po-210 and hence, the cumulative radon gas exposure. The goals of the intercomparison were to: (1) perform collocated measurements using two ...

1998-11-01

492

Developement of the method for realization of spectral irradiance scale featuring system of spectral comparisons  

Energy Technology Data Exchange (ETDEWEB)

Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is ...

2010-10-15

493

Developement of the method for realization of spectral irradiance scale featuring system of spectral comparisons  

International Nuclear Information System (INIS)

Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is ...

2010-10-01

494

Determination of Proper Peaking Time for Ultra Lege detector at Medium Energies  

International Nuclear Information System (INIS)

Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the optimum peaking time for particular detector systems is important. For this purpose, pure Se and Zn elements were excited by 59.5 keV ?-rays from a 50 mCi 241Am annular radioactive source in this study. The characteristic x-rays emitted from pure Se and Zn elements were detected by using an ultra low energy Ge (Ultra-LEGe) detector connecting Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by HM 203-7 oscilloscope connecting amplifier. The proper peaking time for ultra low energy germanium detector (Ultra-LEGe) is determined about 4 ?s.

2008-08-25

495

DESIGN, IMPLEMENTATION AND TESTING OF ... - LAMBDA - NASA  

Science.gov (United States)

FIG. 4. Power Spectral Density of the MAP W11 radiometer. The red and black traces are the power spectral density measurements of the two detectors on the ...

496

Comparison of effectiveness of three radon detectors (LR115, CR39 and silicon diode pin) placed in a cylindrical device -theory and experimental techniques  

Energy Technology Data Exchange (ETDEWEB)

Researchers at the Laboratory of Nuclear Microanalysis in Besancon (France) are developing and improving radon measurements in order to detect and analyse, more precisely radon emanation anomalies in both fields of Earth Sciences and Radioprotection. In order to characterize radon emanation, two complementary techniques are developed; continuous measurement through a portable proportional counter and passive measurements by nuclear track detectors for both fieldwork and laboratory analysis. A mathematical model is being devised to interpret the nuclear track detector response. This model is performed according to the device characteristics: type of detectors, shape and size of cells and whether a membrane is used or not. In addition to the theoritical study, experimental radon concentration measurements will be reported. (author).

1993-12-31

497

Comparison of effectiveness of three radon detectors (LR115, CR39 and silicon diode pin) placed in a cylindrical device -theory and experimental techniques  

International Nuclear Information System (INIS)

Researchers at the Laboratory of Nuclear Microanalysis in Besancon (France) are developing and improving radon measurements in order to detect and analyse, more precisely radon emanation anomalies in both fields of Earth Sciences and Radioprotection. In order to characterize radon emanation, two complementary techniques are developed; continuous measurement through a portable proportional counter and passive measurements by nuclear track detectors for both fieldwork and laboratory analysis. A mathematical model is being devised to interpret the nuclear track detector response. This model is performed according to the device characteristics: type of detectors, shape and size of cells and whether a membrane is used or not. In addition to the theoritical study, experimental radon concentration measurements will be reported. (author).

499

A Quantum-Enhanced Prototype Gravitational-Wave Detector  

CERN Document Server

The quantum nature of the electromagnetic field imposes a fundamental limit on the sensitivity of optical precision measurements such as spectroscopy, microscopy, and interferometry. The so-called quantum limit is set by the zero-point fluctuations of the electromagnetic field, which constrain the precision with which optical signals can be measured. In the world of precision measurement, laser-interferometric gravitational wave (GW) detectors are the most sensitive position meters ever operated, capable of measuring distance changes on the order of 10^-18 m RMS over kilometer separations caused by GWs from astronomical sources. The sensitivity of currently operational and future GW detectors is limited by quantum optical noise. Here we demonstrate a 44% improvement in displacement sensitivity of a prototype GW detector with suspended quasi-free mirrors at frequencies where the sensitivity is shot-noise-limited, by ...

2008-01-01