WorldWideScience
2

Radiative Heat Transfer Augmentation in High Temperature Combustion Systems with Application to Radiant Tube Burners. Final Report, April 1987-March 1990.  

Science.gov (United States)

Gas fired radiant tube heaters provide an indirect heating source for applications in which direct contact cannot be permitted between combustion gases and the workpiece. The program was an investigation of ways to improve performance of such burners thro...

1990-01-01

3

Heat transfer problems in high temperature heat exchangers  

International Nuclear Information System (INIS)

This paper deals with construction types of high temperature heat exchangers, their circulation loops and temperature differences. Most attention is given to gas dynamics, convective heat transfer, convection and radiant heat transfer interaction in high temperature heat exchangers. The ways of heat transfer augmentation and efficient heat exchanger construction are discussed.

1986-01-01

4

Calculation of the thermal load of a high voltage cable with forced circulation of oil with the help of modeling on an analog computer  

Energy Technology Data Exchange (ETDEWEB)

Equations are compiled for thermal balance in which for simplification, no consideration is made for heat conductivity along the axis of the cable and dependence of losses, heat capacitance and heat conductivity on temperature. Equations are modeled on a transistor analog calculator 42 TA. The solution to the task on the computer produced values of maximum temperature on the cable and coordinates of the point of maximum overheating. Using the analog model, one can study other parameters of the thermal mode.

1980-01-01

5

Development of a solar thermal storage system suitable for the farmhouse heating in northeast China  

Energy Technology Data Exchange (ETDEWEB)

This study reported on the performance of a passive solar radiant floor heating system designed for standard energy-saving farmhouses in northeast China. Weather data in the region was analyzed in terms of solar radiation, temperature, humidity and light levels. The heating characteristics of the building materials such as windows, doors, walls and roofs were also analyzed along with the indoor thermal environment of the farmhouse. The heating load was then calculated along with the size of the thermal storage element and the area of the collector element. The passive solar radiant floor heating system was designed for heating during the winter and cooling in summer. According to the results, the heating characteristics of the system have the potential to improve farming villages environment and the use of renewable ...

2010-07-01

6

The influence of the explosion of the conductor of an electric cable on the dielectric properties of the polymer insulator  

British Library Electronic Table of Contents (United Kingdom)

The electric explosion of a conductor being part of an electric cable is studied. It is ascertained that the electric properties of a polymeric dielectric depend nonlinearly on the maintenance of the ultradisperse metal filler. In the course of the numerous heating-cooling processes of an insulator, a streamlining of the structure of a polymeric composite occurs.

2010-01-01

7

Electrohydrodynamic pumping in cable pipes. Final report  

Energy Technology Data Exchange (ETDEWEB)

Many oil-insulated electric power cables are limited by heat buildup caused in part by the low thermal conductivity of the oil. Circulation of the oil is known to reduce the cable temperature, but can lead to excessive pressure buildup on long cables when using conventional pumping methods. An alternate pumping method using distributed electric fields to avoid this pressure buildup is described. Electrohydrodynamic (EHD) pumping was studied both theoretically and experimentally for possible application in underground cable cooling. Theoretical studies included both analytical and finite-element analysis of the flow patterns driven by travelling electric fields. Experimentally, flow rates in a cable-pipe model were measured under a wide variety of operating conditions. Theory and experiment are in agreement for velocities below 10 cm/s, but higher velocities ...

1983-02-01

8

PILC cable technology and accessories  

Energy Technology Data Exchange (ETDEWEB)

Studies were conducted to examine the pressure on fluid-filled cables of electric power transmission networks in the event of an oil leak. Transition splices between paper-insulated oil-impregnated cable systems (PILC) and solid dielectric cable is difficult to perform. A proper PILC is composed of a means to contain oil within the cable structure and to keep moisture out. A failure of the cable joint could occur if an oil leak dries out the paper. Since oil pressure in most PILC cables is high, strong mechanical means must be devised to contain the oil within the cable. Resin systems, heat shrink systems and wiped lead sleeves to reseal the PILC cable over the splice, are among the methods used to stop an oil leak. A system has been designed using an EPDM tube contained under mechanical pressure; it ...

1996-08-01

9

Free and forced convective cooling of pipe-type electric cables. Volume 1: forced cooling of cables. Final report  

Energy Technology Data Exchange (ETDEWEB)

A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one reported in this volume dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal ...

1981-05-01

10

Free and forced convective cooling of pipe-type electric cables. Volume 2: electrohycrodynamic pumping. Final report  

Energy Technology Data Exchange (ETDEWEB)

A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one, reported in Volume 1, dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal ...

1981-05-01

11

Forced convective heat transfer in cross-corrugated solar air heaters  

Science.gov (United States)

Forced convective heat transfer in a cross-corrugated channel solar air heater has been studied experimentally using air as a working fluid. The channel was formed by two transversely positioned corrugated sheets and two flat thermally insulated side walls. One corrugated sheet was heated by a radiant heater, while the other was thermally insulated. The fluid velocity and temperature, and the wall temperature and the local heat flux across the heated corrugated sheet were measured for a variety of operating flow rates. Experimental results for the channel geometry have yielded the correlation Nu = 0.0743 (Re)[sup 0.76]. This heat-transfer coefficient is about 2.8 times that of a smooth flat channel. The experiments showed that local heat transfer rate was smaller on the valley of the corrugation than that on the peak. The ratio of the local ...

1994-11-01

12

Development of Stronger and More Reliable Cast Austenitic Stainless Steels (H-Series) Based on Scientific and Design Methodology  

Energy Technology Data Exchange (ETDEWEB)

The goal of this project was to increase the high-temperature strength of the H-Series of cast austenitic stainless steels by 50% and the upper use temperature by 86 to 140 degrees fahrenheit (30 to 60 degrees celsius). Meeting this goal is expected to result in energy savings of 35 trillion Btu/year by 2020 and energy cost savings of approximately $230 million/year. The higher-strength H-Series cast stainless steels (HK and HP type) have applications for the production of ethylene in the chemical industry, for radiant burner tubes and transfer rolls for secondary processing of steel in the steel industry, and for many applications in the heat treating industry, including radiant burner tubes. The project was led by Duraloy Technologies, Inc., with research participation by Oak Ridge National Laboratory (ORNL) and industrial participation by a diverse group of companies.

2006-06-30

13

Radiant heating and cooling, displacement ventilation with heat recovery and storm water cooling: An environmentally responsible HVAC system  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the design, operation, and performance of an HVAC system installed as part of a project to demonstrate energy efficiency and environmental responsibility in commercial buildings. The systems installed in the 2180 m{sup 2} office building provide superior air quality and thermal comfort while requiring only half the electrical energy of conventional systems primarily because of the hydronic heating and cooling system. Gas use for the building is higher than expected because of longer operating hours and poor performance of the boiler/absorption chiller.

1998-12-31

14

Energy conservation by means of integrated systems; Beter resultaat door klimaatkwartet  

Energy Technology Data Exchange (ETDEWEB)

Air conditioning is getting maximum attention these days when building new offices. For the new office building of the assurance company Zwitserleven in Amstelveen, Netherlands, a new air conditioning concept is applied, based on four existing air conditioning methods: cold storage and heat storage in the soil, heat pump, double-wall facades with integrated climate control, and radiant heating combined with a cooling system in the ceiling. The integration of these methods not only provides complete climate comfort for the employees but also substantial energy savings. 3 figs.,1 ills.

1995-11-01

15

Unique approach to an old problem: New technology helps BC Hydro locate heat resistance  

Energy Technology Data Exchange (ETDEWEB)

BC Hydro`s approach to improve the performance of its underground transmission lines by employing new computer technology with fibre optic cables was described. Known as Distributed Temperature Sensing (DTS), the technology is expected to increase the capacity of the most heavily-loaded sections of its seven kilometer underground 230 kV transmission system in the Greater Vancouver area. Although it is also a concern in overhead wires, heating is particularly problematic in underground cable systems. DTS uses opto-electronic equipment to launch a laser light down conventional communications-grade fibre optic cables, installed in the same duct as the cables, or in a spare duct next to them. By using high speed measurements and computer processing, it is possible to determine the temperature all along the fibre with very high accuracy, and to locate any point along the length of the ...

1997-06-01

16

Development and Demonstration of a High Efficiency, Rapid Heating, Low NOx Alternative to Conventional Heating of Round Steel Shapes, Steel Substrate (Strip) and Coil Box Transfer Bars  

Energy Technology Data Exchange (ETDEWEB)

Direct Flame Impingement involves the use of an array of very high-velocity flame jets impinging on a work piece to rapidly heat the work piece. The predominant mode of heat transfer is convection. Because of the locally high rate of heat transfer at the surface of the work piece, the refractory walls and exhaust gases of a DFI furnace are significantly cooler than in conventional radiant heating furnaces, resulting in high thermal efficiency and low NOx emissions. A DFI furnace is composed of a successive arrangement of heating modules through or by which the work piece is conveyed, and can be configured for square, round, flat, and curved metal shapes (e.g., billets, tubes, flat bars, and coiled bars) in single- or multi-stranded applications.

2010-01-25

17

Effect of the PVC system?s topology on the dielectric losses in the region of strong electric fields  

British Library Electronic Table of Contents (United Kingdom)

The electrophysical characteristics of the electric cable?s transition into a state of a heterogenic polymer system due to a wire?s explosion were examined. Using cyclic heating-cooling of the composite, the changes in its topology were observed. The latter makes it possible to regulate the dielectric characteristics of the system.

2011-01-01

18

Emergency ampacities of direct buried three phase underground cable systems  

Energy Technology Data Exchange (ETDEWEB)

A thermal model is formulated for the determination of the emergency transient ampacities of a three phase, horizontally spaced underground cable system. The model is based on a finite difference heat transfer analysis and the principle of superposition which permits the summation of the temperature rise of individual heat sources to eventually provide for the temperature rise of a multiple cable system. The thermal model is transformed into a complex computer program that is capable of calculating the real time cable temperature for any change in conductor current. The program is used to calculate the response of conductor temperatures caused by both ramp and step changes in currents for four conductor sizes between 4/0 and 1500 kcmil. The amount of time to reach conductor temperatures of 100/sup 0/C and 120/sup 0/C from a steady conductor temperature of 75/sup 0/C is calculated ...

1983-07-01

19

Calculation of current-carrying capacity of forced cooled high-voltage cable lines  

Energy Technology Data Exchange (ETDEWEB)

The current-carrying capacity of oil-filled cables is increased by forced cooling, which is accomplished by three methods: direct, surface and internal, depending on the relative positions of the cable and the cooling agent. The surface and indirect methods are the simplest and are sufficiently effective methods of cooling and make it possible to improve the current-carrying capacity of cables already mastered by the USSR's industry. A calculation method is suggested for the proper determination of the permissible load on lines of these sorts. A procedure is presented whereby equations are derived which make it possible to calculate the temperature of elements of the system and by means of an iteration calculation a determination is made of the total heat flow from the cable with which the temperature of the conductor along the line does not exceed the permissible value. ...

1982-01-01

20

Testing of the 1-MWth bench-model cavity-receiver steam generator  

Science.gov (United States)

A schematic of the Bench cavity receiver system is given, and the primary objectives, schedule and research plan for each of four tests are discussed. The tests are: (1) cold flow testing to functionally check all valves and their response using high pressure nitrogen gas; (2) a hot checkout to simulate both steady state and transient flux inputs to the receiver which are expected at the French facility; (3) basic performance using solar energy at the French facility; and (4) ir radiant heat testing. (LEW)

21

Reproducibility of the Radiant Panel Test Method (ASTM E ...  

Science.gov (United States)

... Abstract : Interlaboratory evaluation of the Radiant Panel Method (ASTM E 162-67) for flame spread testing of two flexible foam and one hardboard ...

1977-03-01

22

Calculation of the view factors for radiant heat exchange in a new volumetric receiver with tapered ducts  

Energy Technology Data Exchange (ETDEWEB)

The need to increase efficiency of volumetric receivers for use in solar power plants by reducing reradiation losses and increasing the ``volumetric effect`` has promoted the idea of a receiver with tapered ducts. These seems to be very promising since higher efficiency and considerable saving of material can be achieved, as compared to conventional receivers perforated with ducts of constant cross-section. A finite element program is being developed to calculate stationary heat transfer in the tapered ducts by free and forced convection in the gas flow, conduction in walls and in the gas, and solar and thermal radiation. Gas and wall temperatures are considered to be varying only in the flow direction. In order to perform the highly nonlinear calculations of radiative exchange, the exact knowledge of the view factors is necessary. The aim of the present work is to evaluate analytically the view factors in tapered ducts.

1995-02-01

23

Optimisation of solar-heated cavity receivers with paraboloid collectors. Optimierung von solar beheizten Hohlraumstrahlungsempfaengern mit Paraboloidkollektoren  

Energy Technology Data Exchange (ETDEWEB)

The authors investigate the optimisation of solar-heated cavity receivers in which solar energy collected by a paraboloid collector is converted into electrical energy. The focussed solar energy enters the receiver through an aperture to heat the working fluid, which flows inside the receiver tubes and is compressed by the compressor of a gas turbine system, to the highest process temperature. A method of calculating the distribution on the inner receiver surfaces of the solar radiation reflected by the paraboloid collector is presented to begin with. The interchange of radiant energy inside the receiver cavity can be calculated on this basis, including the radiation loads, the temperatures of the inner receiver walls, and the radiative and convective losses. The temperature fields in the tube walls must be known for determining the strength required of receiver tubes; they can be derived from the useful ...

1984-01-01

24

Gas-fired boiler plant  

Energy Technology Data Exchange (ETDEWEB)

A gas-fired boiler plant comprises a burner bed extending over a flat surface and heat exchanger pipes arranged above the burner bed, parallel to the said surface. The heat exchanger tubes comprise pipes equipped with a pluraltiy of flat ribs which extend substantially radially from the said pipes and which are provided in space arrangement over the length of the said heat exchanger pipes. The ribs are provided with bent-off portions. The hot flue gases rising from the burner bed flow through the gaps formed between the said ribs and pipes. In order to improve both the convective heat transmission and the utilization of the radiant heat, the bent-over edges are inclined, at least partly, relative to the surface of said burner bed, the arrangement being selected in a manner to ensure that bent-over portions point towards the burner bed and the rising flue gased ...

1989-10-10

25

Fire preventive materials for nuclear power plants  

International Nuclear Information System (INIS)

With the fire accident in Browns Ferry nuclear power plant as a turning point, the regulation against fire has been strengthened more strictly as seen in the regulatory guide of the United States Nuclear Regulatory Commission. Fire of cables is caused by either the ignition of a cable itself or spread of fire to cables. The aspect of fire is divided into the local ignition and combution and the fire extension and prepagation because of the line-shaped configuration of cables. This report describes the prevention of the spread of fire. As the materials for the prevention of fire spread, fire spread-preventing paint ''Dannekka'', sealant ''Danseal P and L'', and fire prevention tape ''FD tape'' are reported, and the testing method and the results are described in detail. ''Dannekka'' is classified into the solvent dispersion type and the water dispersion type. It may be coated with brush or by spraying. ...

26

Development of a tool to collect insulation oil in a cable connection box without interrupting power supply; Muteiden ni yoru cable setsuzokubakonai zetsuen`yu saishu kogu no kaihatsu  

Energy Technology Data Exchange (ETDEWEB)

While underground power transmission lines have become to use CV cables as the mainstream, existing facilities still use OF cables. Factors of OF cable deterioration include heat cycles during operation and surge intrusion. As a method to diagnose this deterioration in insulation, characteristics tests are performed by collecting insulation oil in a cable connection box. The insulation oil collection work has been done conventionally with the power line stopped to prevent danger from induction voltage. A power uninterruptible oil collection tool was developed recently. The tool consists mainly of an insulator made of epoxy resin, wherein a connection box connector is rotated and loosened by operating an insulating operation rod, with the structure not contacted directly with metallic sheath, so that insulation oil can go through the oil collecting tool and gets collected. ...

1999-02-10

27

Efficient, low emissions gas range cooktop  

Energy Technology Data Exchange (ETDEWEB)

Disclosed is a gas-fired cooktop for a range which provides high thermal efficiency and low emissions of air pollutants, particularly low levels of NO{sub x}. The cooktop includes a perforated tile burner which radiates infrared energy upward at a high flux rate to rapidly quench burner gas temperatures and inhibit the formation of NO{sub x}. A perforated glass-ceramic jet plate positioned between the burner and a cooking vessel transmits most of the radiant infrared energy from the burner to the vessel and also forms jets of combustion products which are directed against the bottom of the vessel fo convective heating. Thermal efficiencies of up to about 70% and NO{sub x} emissions as low as about 15ppM are achieved by the cooktop.

1990-01-09

28

Assessment of radiological safety of Wolsung site at site boundary considering crack impact  

British Library Electronic Table of Contents (United Kingdom)

The number of spent fuel storage facilities in the world continues to increase because of "Wait and See" policies and delay of a permanent disposal plan. The temporary spent fuel storage concept is changing to a pre-disposal storage concept. Strengthened safety concepts are required for expanded spent fuel storage facilities and sites. The Korea Hydro and Nuclear Power Company is planning to construct a reinforced concrete MACSTOR-400 facility at Wolsung. In concrete dry spent fuel storage structures, cracks can occur due to radiant heat and environmental chloride. The likelihood of cracking increases over time. Research on changes in shielding performance from one collinear crack in the surface of a concrete facility has been carried out. However there is no research about public radiolog...

2010-01-01

29

Air conditioning in high rise buildings; Conditionnement d'air dans les immeubles de grande hauteur  

Energy Technology Data Exchange (ETDEWEB)

This two-tomes book brings together the 108 presentations given at the first conference of the international institute of refrigeration (IIF/IIR) about air conditioning in high rise office buildings. The main themes are: general design and control systems, including split systems, radiant panels, fluctuating and gravity ventilation etc..; energy consumption, optimization and heat recovery; cold storage for peak shaving, including ice slurry circulation; indoor air quality; fire and smokes protection, protection against chimney effects and lighting spots; use of fuzzy logic and of neural networks. It includes also a description of the high rise building situation and works in progress in China, Japan and in some other countries. (J.S.)

1997-07-01

30

Designer's handbook for forced-cooled high-pressure oil-filled pipe-type cable systems. Final report  

Energy Technology Data Exchange (ETDEWEB)

This handbook provides the necessary tools for the engineer to design forced-cooled HPOF pipe-type cable systems. It represents the final objective of a major project which included an extensive research program at the Waltz Mill Forced-Cooling Test Facility. The formulas and procedures presented in this handbook are consistent with the results of this program as well as other full-scale and model investigations. Introductory material, including historical information, general design concepts and basic heat transfer and fluid dynamics theory is given for those who are unfamiliar with the fundamental principles of forced-cooling. The nucleus of the handbook consists of equations and calculating procedures for determining forced-cooled parameters and thermal/hydraulic performance levels. Both simple and sophisticated procedures have been provided, with the more complex procedures treating such areas as the thermal interaction between ...

1984-07-01

31

Advanced power cable technology. Volume II. Present and future  

Energy Technology Data Exchange (ETDEWEB)

In this book an attempt has been made to describe the most recent information, but at the same time set out the fundamentals of cable technology in some depth. A focus is directed on general features of various kinds of cables. This book is written for cable engineers, and those interested in cable research, the book will also be useful to university students and management personnel interested in electric power engineering. This volume contains chapters on Present Cables and Their Improvement and New Types of Cables. (CS)

1983-01-01

32

Laboratory development TPV generator  

Energy Technology Data Exchange (ETDEWEB)

A laboratory model of a TPV generator in the kilowatt range was developed and tested. It was based on methane/oxygen combustion and a spectrally matched selective emitter/collector pair (ytterbia emitter-silicon PV cell). The system demonstrated a power output of 2.4 kilowatts at an overall efficiency of 4.5{percent} without recuperation of heat from the exhaust gases. Key aspects of the effort include: (1) process development and fabrication of mechanically strong selective emitter ceramic textile materials; (2) design of a stirred reactor emitter/burner capable of handling up to 175,000 Btu/hr fuel flows; (3) support to the developer of the production silicon concentrator cells capable of withstanding TPV environments; (4) assessing the apparent temperature exponent of selective emitters; and (5) determining that the remaining generator efficiency improvements are readily defined combustion engineering problems that do not necessitate breakthrough technology. The ...

1996-02-01

33

Weld integrity of the superconducting cable aluminium jackets of W7-X  

Energy Technology Data Exchange (ETDEWEB)

The Wendelstein 7-X (W7-X) modular stellarator is under construction at the Max-Planck-Institut fuer Plasmaphysik in Greifswald, Germany. The W7-X magnet system contains 70 coils made up from helium cooled superconducting cables in aluminium alloy (EN AW-6063) jackets. Several hundred connections of the jacket to the cable joints are made by aluminium-to-aluminium welds. Due to geometrical and thermal boundary conditions these welds cannot be accomplished free from defects. Microscopic analyses of the welds show that a variety of small flaws such as cracks and pores develop during welding. The welds have thus to be dimensioned accordingly, and appropriate weld qualification, investigation and testing has to be done in order not to jeopardise the structural integrity and leak tightness. The weld is mechanically loaded during cool-down due to the difference in thermal contractions between the GRP insulation and the aluminium, and during operation ...

2009-06-15

34

Weld integrity of the superconducting cable aluminium jackets of W7-X  

International Nuclear Information System (INIS)

The Wendelstein 7-X (W7-X) modular stellarator is under construction at the Max-Planck-Institut fuer Plasmaphysik in Greifswald, Germany. The W7-X magnet system contains 70 coils made up from helium cooled superconducting cables in aluminium alloy (EN AW-6063) jackets. Several hundred connections of the jacket to the cable joints are made by aluminium-to-aluminium welds. Due to geometrical and thermal boundary conditions these welds cannot be accomplished free from defects. Microscopic analyses of the welds show that a variety of small flaws such as cracks and pores develop during welding. The welds have thus to be dimensioned accordingly, and appropriate weld qualification, investigation and testing has to be done in order not to jeopardise the structural integrity and leak tightness. The weld is mechanically loaded during cool-down due to the difference in thermal contractions between the GRP insulation and the aluminium, and during operation ...

2009-06-01

35

Combustion for high temperature heating process  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the high-temperature (1500/sup 0/C or higher) heating technology by combusting natural gas. The theoretical adiabatic flame temperature is 1957/sup 0/C at the theoretical air ratio and 2801/sup 0/C at the theoretical oxygen ratio. The flame temperature is increased by 40/sup 0/C every 1%-increase of oxygen up to 25% of the concentration of oxygen and by 28/sup 0/C to 30% of it. The flame temperature is increased by 37 to 38/sup 0/C every 100/sup 0/C-increase of the temperature of preheated air. The practical temperatures are significantly lower than the theoretical ones. The ceramic calciner is provided with a two-stage burner for 1600 to 1800/sup 0/C which can use also the oxygen-riched air. The glass melting furnace is operated at 1500/sup 0/C and the flat flame burner is used for a single kiln. A stabilizing burner is used for reducing the multing time for the steel making electric arc furnace. A high-temperature (1700/sup 0/C) ...

1987-12-05

36

Screening of Flexible Cables by Nonlinear Resistance ...  

Science.gov (United States)

... Abstract : Two traces in flexible cables used in the Milstar agile beam antenna system failed during acceptance testing. ...

1994-01-10

37

A review of the technical development of electric cables in the history of the Berlin electric utilities. Ein Rueckblick auf die Berliner Kabeltechnik aus Sicht der Energieversorgung  

Energy Technology Data Exchange (ETDEWEB)

The technical development of electric cables in the history of the Berlin electric utilities looks back on more than one century of continuous progress from jute-insulated direct-voltage cables, to 30 kV paper-insulated mass-impregnated cables, 110 kV plastic-insulated cables, 380 kV oil-filled cables, and 380 kV XLPE cables which are increasingly used today. A brief review informs about the major stages of power cable development. (orig.).

1992-05-15

38

HVDC submarine cables for the Hokkaido Honshu linkage  

Energy Technology Data Exchange (ETDEWEB)

The direct-current submarine cable interconnecting Hokkaido and Honshu (hereafter called HH linkage) is an example of installation of an undersea cable for long-distance power transmission crossing a sea strait. In particular, the feature of this interconnection is that an oil-filled (OF) cable is used for the high-voltage side with crosslinked polyethylene (XPLE) cable adopted for the return to comprise a conductor return system. The details of the facilities, especially the design of the OF submarine cable are described. 3 refs.

1981-04-01

39

Experimental and theoretical studies of solar steam reforming assisted by molten salts  

Energy Technology Data Exchange (ETDEWEB)

The pathway to hydrogen generation entirely from renewable energy and material sources probably goes by a transitional period with the utilization of hybrid fossil/renewable integrated systems. Solar steam reforming of methane is set in this context, specifically suited for a country like Italy whose actual energy policy is mainly based on the imported NG, but also characterized by convenient solar radiation levels in the Southern Regions. A new solar SMR process is being developed by ENEA, using molten nitrates as solar heat carriers and storage medium at about 550 C. The potential of this process have been proved theoretically by process simulation studies. Engineering and experimental activities aimed to the development of a prototype apparatus are now in progress in ENEA's laboratories. It is remarkable that the developed technology (MS powered SMR) can find interesting impact in the in industrial chemistry wherever it is convenient decoupling the ...

2010-07-01

40

A. C. losses in the SSC high energy booster dipole magnets  

Energy Technology Data Exchange (ETDEWEB)

The baseline design for the SSC High Energy Booster (HEB) has dipole bending magnets with a 50 mm aperture. An analysis of the cryogenic heat load due to A.C. losses generated in the HEB ramp cycle are reported for this magnet. Included in this analysis are losses from superconductor hysteresis, yoke hysteresis, strand eddy currents, and cable eddy currents. The A.C. loss impact of 2.5 {mu}m vs. 6 {mu}m filament conductor is presented. A 60 mm aperture design is also investigated. 8 refs., 3 tabs.

1991-06-01

41

OXYGEN-ENRICHED COAL COMBUSTION WITH CARBON DIOXIDE RECYCLE AND RECOVERY: SIMULATION AND EXPERIMENTAL STUDY  

Energy Technology Data Exchange (ETDEWEB)

Two computational problems were worked on for this study. The first chapter examines the option of coal combustion using oxygen feed with carbon dioxide recycle to control the adiabatic flame temperature. Computer simulations using an existing state-of-the-art 3-dimensional computer code for turbulent reacting flows with reacting particles were employed to study the effects of increased carbon dioxide mole fraction on the char burnout, radiant heat transfer, metal partitioning, and NOx formation. The second chapter compares assumptions for the CO/CO{sub 2} ratio at the surface of mineral inclusions made in previous studies to predictions obtained from a pseudo-steady state kinetic model (SKIPPY) for a single porous particle. The detailed kinetic simulations from SKIPPY for varying particle sizes and bulk gas compositions were used to develop algebraic expressions for the CO/CO{sub 2} ratio that can be incorporated into metal vaporization ...

2002-02-28

42

Design and performance of a solar-powered air-conditioning system in a green building  

Energy Technology Data Exchange (ETDEWEB)

A solar-powered adsorption air-conditioning system was designed and installed in the green building of Shanghai Research Institute of Building Science. The system contained 150 m{sup 2} solar collectors and two adsorption chillers with nominal refrigeration capacity of 8.5 kW. Based on performance characteristics of the adsorption chiller, the operation mode of the solar-powered air-conditioning system was optimized by maintaining a phase shift of 540 s between the two adsorption chillers. Thereafter, the whole system realized stable operation by the balance of heat consumption and refrigeration output. From June to August of 2005, the solar-powered air-conditioning system continuously ran between 9:00 and 17:00. The operation performance of the system under representative working condition showed that the average refrigeration output of the solar-powered air-conditioning system was 15.3 kW during an 8 h operation and the maximum value exceeded 20 kW. Solar ...

2008-05-15

43

Analysis of natural convection in narrow annular gaps of LMFBR  

International Nuclear Information System (INIS)

The natural convection characteristics of gas in a vertical narrow annular gap which had its bottom opened to high temperature fluid and its upper shielding exposed to low temperature sealant have been evaluated from simulated fluid experiments using water and from calculations using the three-dimensional thermal hydraulic analysis computer code THERVIS-III. The following results were obtained: (1) The critical Rayleigh number which represented the limit of convection generation increased as the aspect ratios #epsilon#_1 (height/circumference) and #epsilon#_2 (height/gap distance) increased. (2) The flow pattern along the circumferential direction was seen to depend more strongly on the radiant heat from the side wall, rather than the aspect ratios #epsilon#_1 and #epsilon#_2. (3) The temperature difference along the circumferential direction in the annular gap obtained from the calculation code coincided with that obtained from experiments ...

44

On-line partial discharge measurements and off-line dielectric spectroscopy measurements of six 115 kV XLPE cable systems  

Energy Technology Data Exchange (ETDEWEB)

This paper reported on a study in which partial discharge (PD) measurements were performed on 6 underground transmission cable circuits to determine the effectiveness of PD measurements on fluid fill cables. The cables were between 37 and 56 years old. PD activity was detected from the terminations of H11L and H3L Cable 2. However, for cables from H3L Basin TS to Mill Street junction, PD activity was detected originating from within the main cable insulation.

2009-07-01

45

Checking the condion of 500 kV cable lines by chromatographic analysis of gases dissolved in oil  

Energy Technology Data Exchange (ETDEWEB)

A chromatographic technique is described for checking the condition of cable insulation by analyzing cable oil for the gases that are typical of defects in power transformers: carbon dioxide, acetylene, methane and ethylene. This technique was successfully used for predicting breakdown of insulation on KL-2 cable at one of the hydroelectric plants of Kirgizglavenergo power grid 1.5 months in advance. The presence of the above-mentioned gases in cable oil can provide a signal for monitoring the state of cable insulation. Further research is needed in addition to more operational experience to work out criteria for objective evaluation of the state of cable lines.

1980-03-01

46

VUV efficiency and radiant emittance characterization of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

The pure xenon dc positive column discharge has been characterized for various xenon pressures, currents, and discharge tube radii. The absolute output at the 147 nm resonance transition has been measured using two independent techniques to yield the radiant emittance at 147 nm (power per unit surface area). The efficiency of 147 nm production is obtained by combining the measured radiant emittance with the measured electrical power per unit length deposited in the gas. The radiant emittance and the efficiency are the two principle figures of merit for characterizing the discharge as a source of VUV radiation. It is observed that the trends in efficiency and radiant emittance change substantially when the discharge transitions from two-step electron impact excitation/ionization at higher pressures to single-step electron impact ionization at lower pressures. Modeling of the xenon positive column ...

1996-12-31

47

Satellite Calibration Data. Annual Data Report - 1977  

Science.gov (United States)

... in Taylor and Williamson.* Most satellite sensors cannot be ... The coordinates of the rocket Ii ... I - Incoming Global Radiant Flux between 0.285 and ...

1979-08-01

48

Very high voltage cables with synthesis insulation; Les cables tres haute tension a isolation synthetique  

Energy Technology Data Exchange (ETDEWEB)

A historical review on insulated cables for power transmission, is presented, beginning with impregnated paper insulation, oil filled cables and natural rubber cables. High density and chemically reticulated polyethylene were then used for high voltage and very high voltage cables; the advantages of polyethylene compared to impregnated paper cables are discussed, which led to research programs at EDF on various themes concerning the optimization of polyethylene cables: dielectric properties and reliability, thermomechanical behaviour, thermal ageing of materials, testing methods (acceptance dielectric test and long duration temperature test); utilization of low- and high-density and chemically reticulated polyethylene for 225 kV cables is discussed

1997-06-01

49

Development of new 500kV laminated paper insulated self-contained oil-filled cable and its accessories  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the development of cellulose paper/plastic film/cellulose paper laminate insulated Self-Contained 500 kV Oil-Filled (OF) Cable and its accessories. Dielectric loss of this new cable was confirmed to be about one third that of conventional kraft paper cable. Moreover, by employing the reduced insulation thickness of 25 mm rather than that of 33 mm, as is usual with conventional cables, the new cable could be made very compact, due to the high dielectric strengths of laminated paper. As a result, the shipping reel length of the new cable, which is about 10% lighter in total weight and 10% smaller in overall diameter than conventional cables, could be dramatically increased. The reliability and the stability of the new cable have been demonstrated by the successful completion of a one and a half year ...

1988-01-01

50

Oil cable pumping plant. Pumpestasjon  

Energy Technology Data Exchange (ETDEWEB)

The invention deals with a pumping plant for oil filled power cables. An air driven piston type pump is used as primary pump. A PLS (Programmable Logic control System) is used to control the oil flow to the cable(s). Improvements of the pump includes means for ensuring that the pump piston is operated also at low pressure and flow, and means for sealing off the piston rod to ensure maximum life of seals, to facilitate detection of possible leakages and to avoid contamination of the cable oil. 3 figs.

1988-12-27

51

110-500 kV high-pressure cables  

Energy Technology Data Exchange (ETDEWEB)

The use of oil-filled high-pressure electric cables has increased significantly. In recent years, the electric cable industry has developed new designs, manufacturing technology, and has mastered the production of 110 to 220 kV cables without using a temporary lead sheath. The design, fabrication, and performance of high-pressure electric cables for power systems are discussed.

1982-08-01

52

Investigation of anomalous CXR response of filled cables  

Energy Technology Data Exchange (ETDEWEB)

An anomaly in the continuous X-ray (CXR) response of filled cables is described. A systematic investigation of this anomaly is pursued with a single cable type and a model explaining the anomaly is presented. The effect of the anomaly on the accuracy of CXR measurement of SGEMP response is discussed.

1982-12-01

53

Improving performance of e. h. v. cable systems  

Energy Technology Data Exchange (ETDEWEB)

Following an earlier article on developments to enhance the reliability of supertension oil filled cables and accessories, changes are described in design and installation of complete cable systems which have similarly improved operating performance.

1983-03-04

54

Evaluation of a solid hydrophone cable  

Energy Technology Data Exchange (ETDEWEB)

In marine seismic exploration, an approximately two-mile long hydrophone cable is towed behind the ship. The commonly employed cable consists of a kerosene-filled hose enclosing hydrophones, electrical wires, and steel ropes. The kerosene provides buoyancy while the steel ropes are for structural support. For deep-water operations, the cable is pulled through the water at a depth of 20-40 feet. For shallow water, a bottom reference configuration is used and the cable is dragged. This paper presents a comparison of electroacoustic properties between a newly designed, buoyant solid cable and those of the conventional kerosene-filled hose. The emphasis is on drag cable operations. Cable maintenance is a major problem. Jacket cuts occur because of improper handling or collisions with other ships, subsea structures, and debris. Kerosene leakage ...

1982-07-01

55

CFCC radiant burner assessment. Final report, April 1, 1992--July 31, 1994  

Energy Technology Data Exchange (ETDEWEB)

The objective of this work was to identify methods of improving the performance of gas-fired radiant burners through the use of Continuous Fiber Ceramic Composites (CFCCs). Methods have been identified to improve the price and performance characteristics of the porous surface burner. Results are described.

1994-11-01

56

A radiant temperature numerical method for laser-plasma diagnostic using SXRSC with absorption method  

International Nuclear Information System (INIS)

An numerical method was developed for measuring radiant temperature using a set of absorption-foils coupled to soft x ray streak camera, SXRSC, in laser plasma experiments. An numerical code, SCC, was given. An x-ray intensity ratio vs temperature was calculated for Parylene, C_3H_6, Mylar and Aluminium. A suitable range of the measuring temperature was discussed to some absorber.

1990-01-01

57

Mercury-free fluorescent lighting  

Energy Technology Data Exchange (ETDEWEB)

A brief comparative review of possible mercury free fluorescent lighting technologies is presented, including rare-gas positive column discharges, molecular discharges, and dielectric barrier discharges. Detailed experimental results on xenon positive column discharges will then be considered. In order to judge whether xenon-based discharges are a viable UV source it is necessary to measure the radiant emittance (power per unit area) for the vacuum ultraviolet (VUV) resonance xenon emission at 147 nm. Two techniques to determine the VUV radiant emittance have been developed and applied to xenon discharges. One method combines the measured resonance level density using absorption spectroscopy and a calculation of the trapped decay rate for the resonance radiation to arrive at the radiant emittance at 147 nm. A second method utilizes a direct measurement of the radiance (power per unit area per unit solid angle) at 147 nm ...

1996-05-01

58

The condition monitoring of fluid-filled taped cables employed in underground transmission through dissolved gas analysis  

Energy Technology Data Exchange (ETDEWEB)

There is an urgent need to monitor the condition of fluid-filled taped (FFT) cables. The Dissolved-Gas Analysis (DGA) technique that has been successfully applied to power transformers holds great potential for the preventive maintenance of FFT cables. However, before this emerging technique can be properly applied to cables, a suitable fluid sampling and subsequent gas analysis method had to be developed, including the generation of both laboratory and field data to aid in data interpretation. Data on gas saturation levels in various cable fluids have been presented. This paper describes a novel method developed specifically for FFT cables and discusses field results so obtained. The type, distribution and concentration of gases from fluid alone and paper alone under electrical stress has been presented, including the differences between normal and not-so-normal ...

1994-12-31

59

Life estimation of high-voltage electric cable. Koden prime atsu cable no jumyo yosoku  

Energy Technology Data Exchange (ETDEWEB)

An explanation is given of life estimation of CV cable and OF cable which are generally used as high-voltage power cable. CV cable uses XLPE (crosslined polyethylene) and OF cable uses oil-immersed paper as electrical insulators. Relating to CV cable, voltage deterioration due to partial discharge and electric treeing occurs in a high electric field, and by extrapolating the data of up to the actually used electric field in this high electric field, the life is estimate (there is an n-power deterioration law which is V{sup n} = t between breakdown voltage V and electric applied time t). Validity of this extrapolation, however, is a future issue. Further, in the use under the immersion condition, water tree deterioration phenomena influenced by water content and the electric field which are characteristic of CV cable are seen even in the ...

1991-12-15

60

Development of Stronger and More Reliable Cast Austenitic Stainless Steels (H-Series) Based on Scientific Design Methodology  

Energy Technology Data Exchange (ETDEWEB)

The goal of this program was to increase the high-temperature strength of the H-Series of cast austenitic stainless steels by 50% and upper use temperature by 86 to 140 F (30 to 60 C). Meeting this goal is expected to result in energy savings of 38 trillion Btu/year by 2020 and energy cost savings of $185 million/year. The higher strength H-Series of cast stainless steels (HK and HP type) have applications for the production of ethylene in the chemical industry, for radiant burner tubes and transfer rolls for secondary processing of steel in the steel industry, and for many applications in the heat-treating industry. The project was led by Duraloy Technologies, Inc. with research participation by the Oak Ridge National Laboratory (ORNL) and industrial participation by a diverse group of companies. Energy Industries of Ohio (EIO) was also a partner in this project. Each team partner had well-defined roles. Duraloy Technologies led the team by ...

2006-04-15

61

Ethernet networks technology in electrical substations  

Energy Technology Data Exchange (ETDEWEB)

In both office and home environments, Ethernet represents the dominant networking technology in use. Ethernet is low cost and the networks are fairly understood by users. The author began by explaining the physical and data link layers of Ethernet, then touched on fibre-optic cables. The industrial protocols were discussed, followed by Ethernet network topology. The environmental robustness of Ethernet networks was reviewed, with a word of caution from the author, advising to properly evaluate whether Ethernet represents a mission-critical component of the substation, as substation control houses are not environmentally controlled spaces, often minimally heated and no cooling. Engineering access to station Integrated Electric Drives (IEDs). By properly connecting Ethernet networks, it is possible to access relays in the substations from desktop engineering workstations in the central office. Network security issues must be addressed to prevent ...

2002-07-01

62

An evaluation of the embedment of a Radio Frequency Integrated Circuit with a temperature detector in building envelopes for energy conservation  

British Library Electronic Table of Contents (United Kingdom)

Concrete is the primary material for building envelopes in some parts of the world, and its ability to store heat as well as its dynamic temperature changes will not only affect the deterioration rate of the exterior wall but will also greatly influence the energy efficiency of interior air conditioning. There are many methods for measuring the inner temperature of concrete, but they often have limitations, such as indirect estimation, cable installation requirements, high cost, or heterogeneity of the sample structure. In order to measure the internal temperature of concrete, this study integrated a Radio Frequency Integrated Circuit (RFIC) with a temperature sensor chip and embedded the device in concrete structures. A Smart Temperature Information Material (STIM) was thus developed. Thi...

2011-01-01

63

XLPE cables move in on underground transmission  

Energy Technology Data Exchange (ETDEWEB)

Recent developments in cross-linked polyethylene cables mean they can be used at higher voltages and are starting to replace some oil-filled cables. Their good thermal and electrical properties, easy installation and minimal maintenance have helped their growth. A group at Sumitomo Electric Industries Ltd., Japan is studying the performance of these cables. (author).

1986-02-01

65

Long term accelerated aging tests on distribution cables under wet conditions  

Energy Technology Data Exchange (ETDEWEB)

Two accelerated aging test procedures are proposed for use on solid dielectric extruded distribution cables under wet conditions. One test method is a fixed time duration test in which the degree of cable specimen aging is assessed in terms of breakdown tests, while the other test method is a time to breakdown test in which the cable specimens are voltage stressed until failure ensues.

1996-10-01

66

Fuel wood yarder  

Energy Technology Data Exchange (ETDEWEB)

A small cable yarding system for accumulations of slash on forested land and overstocked non-productive stands is described.

1984-01-01

67

Evaluation of 230 kV HPFF pipe-type cable with wrinkled and creased insulating tapes  

Energy Technology Data Exchange (ETDEWEB)

Severe collapse wrinkles and circumferential creases were discovered in the cellulose paper insulating tapes of a newly installed IIPFF pipe-type cable during splicing and terminating. An evaluation program was developed to assess the electrical and mechanical integrity of the cable having wrinkled and creased insulating tapes. The test results indicated that the cable would perform satisfactorily in service.

1995-01-01

70

Cable lines for 500 kV  

Energy Technology Data Exchange (ETDEWEB)

Application, design, and installation of the cable line in steel pipe with oil under pressure for 500 kV is considered. The cable construction and design specifications are presented. Manpower requirements for the installation of the cable, extending from the hydrogenerators to the outdoor switchgears or to the change point where they are connected to overhead power lines, are discussed and data provided.

1980-08-01

72

Monitoring oil pressure in h. v. cables  

Energy Technology Data Exchange (ETDEWEB)

The paper-insulated low-pressure oil-filled cable invented in 1917 has been used throughout the world as the major cable system for voltages from 33kV to 525kV and experimentally to 1100kV. The proven reliability of the design is amply demonstrated by the cables installed in the early 1930s still currently in service. The inherent design of an oil-filled cable requires that the low viscosity oil is retained within a lead or aluminium sheath. Changes in oil volume due to changes in ambient temperature and load are accommodated by oil reservoirs which maintain the cable oil pressure within design limits. A microprocessor monitoring system that allows early detection and quick location of oil leaks from high voltage oil-filled cables is described.

1985-03-01

73

High voltage cable in municipal electricity supply  

Energy Technology Data Exchange (ETDEWEB)

The author explains current developments in high voltage cable technology and subsequently describes problems inherent in its application, from the users viewpoint, in municipal electricity supply. The planning of a high voltage cable network and the selection of a specific type of cable are not only dependent on the typical properties of various cables but to a major degree also on the feasible laying technique, the power transmitted, the costs, the stellation treatment of the high voltage network, the acceptance requirement, the inductive influence from telecommunication cable, thermal influences from the environment, eventual safeguards from mechanical and chemical damage to the network, frequency of failure and surveillance and breakdown location. In conclusion, the author portrays potential developments in the fields of high and maximum voltage cable from ...

1980-12-22

74

Method of fusing segments of armored logging cables  

Energy Technology Data Exchange (ETDEWEB)

The method is used for repairing armored logging cables. It consists of preparing armor, subsequent connection of current-conducting strands and wires of the armor, and laying of the armor. Sections of connecting the wires of the armor of the lower and upper layers are scattered over the length of the fused section of the cable. In order to improve the fault strength of the cable, the junctions of connection of the armor wires are scattered among themselves at a distance determined by the Euler formula, and thermal tempering of the wire sections is carried out near these junctions, and then the fused section of the cable is reinforced.

1982-01-01

75

Development of 275kV oil-filled cable insulated with polypropylene laminated paper (PPLP)  

Energy Technology Data Exchange (ETDEWEB)

In 1969, the authors started R and D on a polypropylene laminated paper (PPLP) as a new low-loss insulating paper for oil-filled (OF) cables. Through the material research and the trial manufacture of 275 kV OF cable and four years of long-term field test, PPLP has reached the stage of commercial use. This paper introduces a summary of the history of the development of PPLP, the characteristics of PPLP and cable, the results of long-term field test of 275 kV cable, and other relevant data.

1982-12-01

76

Analysis on Fault for the Underground Cable Systems at Home  

Energy Technology Data Exchange (ETDEWEB)

Many power apparatus and underground cable systems have been constructed since 1970 in korea. Recently, as the needs for underground T and D systems increase rapidly, any fault on the systems causes enormous economic losses in our society. Thus, this paper described. (1) Survey on the amount and the increasing rates of the underground cable systems at home and abroad. (2) Survey on fault data for the underground cables and joints at home and abroad.From the analysis on fault data, we analyzed the cause of fault and classified the typical fault mode for the underground cable systems. (author). 5 refs., 3 figs., 11 tabs.

1999-05-01

77

Vacuum ultraviolet radiometry of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two quantities are combined to yield the radiant ...

1995-10-01

78

Radiant flash pyrolysis of biomass as a source of fuels and chemicals  

Energy Technology Data Exchange (ETDEWEB)

Last year a team of US and French scientists using the Odeillo (France) 1MW/sub th/ solar furnace showed concentrated solar radiation to be an effective means for rapidly volatilizing biomass materials. The results of continuing research in the U.S. on radiant flash pyrolysis of biomass as a source of fluid fuels, industrial feedstocks and chemicals are described. Bench scale sources of intense, visible radiant energy have been used to simulate the concentrated solar flux available at the focus of solar towers. Windowed transport reactors are being developed, which act as cavity receivers for the focused radiant energy and provide a means for direct use of the radiation to rapidly pyrolyze the entering biomass. One of these reactors will be operated at the focus of the Georgia Tech 400kW/sub th/ solar furnace next August. Preliminary results from the bench scale reactor experiments, and plans for the Georgia Tech ...

1980-01-01

79

Rehabilitation of a gassy low pressure liquid filled 115 kV cable  

Energy Technology Data Exchange (ETDEWEB)

The recent attempt to degassify a self contained liquid filled (SCLF) cable in Ontario Hydro is described. In September 1989, there was a high pressure alarm on one phase of a SCLF 115 kV cable circuit. The direct buried cable circuit is about 1,890 m long with two joints and was installed in 1968. Oil samples from the cable had 10 to 12% gas content with high levels of hydrogen, methane, and ethane, and very low levels of carbon monoxide, carbon dioxide, and acetylene. From these results it was concluded that the gas was generated by low energy electrical discharges and the paper insulation was not degraded. Various utilities and cable manufacturers were contacted to find if they had experienced similar problems. The cable duct oil was flushed and gasified and the successive oil samples were analyzed in order to locate the gassing site. The joints were examined ...

1994-12-31

80

Eddy current inspection of superconducting cable during manufacturing  

Energy Technology Data Exchange (ETDEWEB)

The downstream failure of cable during winding, insulating, coil winding, and coil assembly is a significant issue in magnet production. The impact of these failures are costly both financially, and from the time to recover from this downstream failure. The current approach to cabling has been to visually inspect the cable for any gross defects during cabling. To date this has been effective in finding small defects such as crossovers for example, which drastically reduce the mechanical integrity of the strand, and thus the cable itself. But because of the large volume of cable which will be manufactured an automated flaw detection system which can inspect the cable and detect these type of defects will be needed. We have recently done an on-line experiment using an Eddy current system, and specialized Eddy current probes to inspect ...

1992-03-01

81

Eddy current inspection of superconducting cable during manufacturing  

International Nuclear Information System (INIS)

The downstream failure of cable during winding, insulating, coil winding, and coil assembly is a significant issue in magnet production. The impact of these failures is costly both financially and because of the time needed to recover from them. The current approach to cabling has been to visually inspect the cable for any gross defects during cabling. To date this has been effective in finding small defects such as crossovers, which drastically reduce the mechanical integrity of the strand and thus of the cable itself. But because of the large volume of cable that will be manufactured, an automated flaw detection system that can inspect the cable and detect these types of defects will be needed. We have recently done an on-line experiment using an Eddy current system and specialized Eddy current probes to inspect cable ...

1992-03-04

82

Design, manufacturing, installation, protection of 345 kV 750 MVA submarine power cables in New York  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the criteria used for the thermal, electrical, mechanical, hydraulical design of the submarine power cables crossing Long Island Sound to feed New York City. The cables are of the self contained fluid filled (SCFF) type. There is also a description of the special measures adopted to face the exceptionally aggressive environment, due to presence of hydrogen sulphide and of stray currents (caused by electric railways and pipes cathodic protection). The most significant example of such measures is a third sacrificial armour. Four single-core SCFF cables (one spare) were manufactured in Arco Felice (near Naples, Italy), for the New York Power Authority. The average length of the cables is 13 km, jontless. The Italian cable ship 'Giulio Verne', managed by Pirelli, was utilized for the transportation and laying. The ship is equipped with a turntable ...

1992-04-01

83

Increasing the operational safety of nuclear facilities by using special insulation parts in the containment zone  

International Nuclear Information System (INIS)

LOCA (Loss of coolant accident) resistant heat-shrinkable polymeric products are widely used for the connection of LV cables for class 1E systems inside the containment area of nuclear power plants. The paper/presentation describes the verification of a reformulated compound for these products, where certain components of the compound formulation had to be substituted. A qualification programme with this so-called reformulated compound was undertaken to proof the equivalency of the products to the products made out of the original compound. The basic elements of this requalification project were material qualification tests including accelerated aging tests according to the arrhenius method and type tests in accordance to IEEE 383, including flammability tests. The test results showed that the products made out of the reformulated compound were similar in fit, form and function to the original products. Additional tests have also proven higher ...

2005-06-15

84

Radiant Energy Power Source for Jet Aircraft. Final performance report  

Energy Technology Data Exchange (ETDEWEB)

This report beings with a historical overview on the origin and early beginnings of Radiant Energy Power Source for Jet Aircraft. The report reviews the work done in Phase I (Grant DE-FG01-82CE-15144) and then gives a discussion of Phase II (Grant DE-FG01-86CE-15301). Included is a reasonably detailed discussion of photovoltaic cells and the research and development needed in this area. The report closes with a historical perspective and summary related to situations historically encountered on projects of this nature. 15 refs.

1992-02-01

85

Radiant Energy Power Source for Jet Aircraft  

Energy Technology Data Exchange (ETDEWEB)

This report beings with a historical overview on the origin and early beginnings of Radiant Energy Power Source for Jet Aircraft. The report reviews the work done in Phase I (Grant DE-FG01-82CE-15144) and then gives a discussion of Phase II (Grant DE-FG01-86CE-15301). Included is a reasonably detailed discussion of photovoltaic cells and the research and development needed in this area. The report closes with a historical perspective and summary related to situations historically encountered on projects of this nature. 15 refs.

1992-02-01

86

ITER Core Imaging X-Ray Spectrometer Conceptual Design and Performance Assessment - Phase 2  

International Nuclear Information System (INIS)

During Phase 2 of our study of the CIXS conceptual design we have tackled additional important issues that are unique to the ITER environment. These include the thermal control of the crystal and detector enclosures located in an environment with a 100-250 C ambient temperature, tritium containment, and the range of crystal and detector movement based on the need for spectral adjustments and the desire to make measurements of colder plasmas. In addressing these issues we have selected a ''Dewar''-type enclosure for the crystals and detectors. Applying realistic view factors for radiant heat and making allowance for conduction we have made engineering studies of this enclosure and showed that the cooling requirements can be solved and the temperature can be kept sufficiently constant without compromising the specification parameters of the CIXS. We have chosen a minimum 3 mm combined thickness of the six beryllium windows needed in a Dewar-type ...

87

Oil-filled electric cable with alternate layers of plastic and paper tape  

Energy Technology Data Exchange (ETDEWEB)

This patent describes an oil-filled electric cable and a manufacturing method for said cable, in which the solid insulation is formed, at least in part, by separately applied, alternate layers of cellulose paper tape and of film tapes made of plastic. Prior to application of the tapes around the cable conductor, the moisture content of the paper tape is selected and the swelling of the plastic tape by the oil after application is adjusted, if necessary, such as by immersing the plastic tape in the oil prior to application, so that the swelling of the plastic tape by the oil in the formed cable is offset by the shrinkage of the paper tape during drying of the cable. Also, an apparatus for pre-swelling the plastic tape is described. 4 figs.

1988-01-12

88

MPS [More Power Submarine] cables could be MIND [Mass Impregnated Non-Draining Cable] blowing for 1200 MW links  

Energy Technology Data Exchange (ETDEWEB)

ABB High Voltage Cables AB started the MPS (More Power Submarine cables) project in 1993 with a view to exploring new technology opportunities. The goal is to design and type test a submarine HVDC cable for a capacity of 1200 MW at 600 kV. On the day before ABB announced its success in winning the contract for the world`s largest ever submarine HVDC link project for the gigantic Bakun project in Malaysia, ABB Power Systems described progress to date at a symposium in Karlskrona. The proceedings included a test demonstration on an extruded cable which eventually broke down at a stress of over 935 kV -not in the insulation itself but in the end terminations. The electric field was in excess of 200 kV/mm which is higher than ever before reported. (UK)

1996-07-01

89

External gas pressure oil filled cable; Gasaussendruck-Oelkabel  

Energy Technology Data Exchange (ETDEWEB)

Only two types of 110-kV-cables: Namely XLPE-Cables and External-Gas-Pressure-Cables will be reinstalled in the Federal Republic of Germany. XLPE-Cables have been already developed for higher voltages. An idea how the external-gas-pressure-cable could be made fit for higher voltage levels will be given in this paper. (orig.) [Deutsch] In der Bundesrepublik Deutschland werden in der Zukunft nur noch zwei Kabeltypen der 110-kV-Ebene den Kabelmarkt beherrschen, naemlich: VPE-Kabel und Gasaussendruck-Kabel. Waehrend VPE-Kabel auch fuer hoehere Spannungsebenen bereits entwickelt worden sind, wird im folgenden vorgeschlagen, wie auch das Prinzip der Gasaussendruck-Kabel zu hoeheren Spannungen hin erweitert werden kann. (orig.)

1997-06-02

90

Computerized pressure monitoring and control of Hydro-Quebec`s fluid-filled high-voltage underground cable network in Montreal  

Energy Technology Data Exchange (ETDEWEB)

The development and installation, by Hydro-Quebec, of a computerized pressure monitoring and control system on its fluid-filled high voltage underground cable network in Montreal, was described. The average age of these underground fluid-filled cables is more than 30 years and the cost to replace the circuits is estimated to be 230 million dollars. It is, therefore, crucial to maintain at all times and under all operating conditions a positive oil pressure in order to maintain the dielectric strength of paper insulation, and to prevent air and moisture from entering the cables and accessories. The monitoring and control system is reliable, flexible, user friendly and easy to upgrade. It reduces intervention time on the cables and ensures the protection of the cable network by remotely operating valves to connect oil reserve banks and by providing efficient maintenance management ...

1996-08-01

91

Radiographic experience with power transmission equipment  

Energy Technology Data Exchange (ETDEWEB)

This paper describes radiography as one of the most efficient and cost effective methods for inspecting electric cabls. Details of one project in particular, i.e., the inspection of high-pressure, oil-filled, pipe-type cables (HPOF) are given. 2 refs.

1980-01-01

92

Polypropylene/paper laminates as high voltage power cable insulation  

Energy Technology Data Exchange (ETDEWEB)

A study was carried out to identify optimal laminate/oil combinations for low pressure oil filled and high pressure pipe-type cables, and to establish taping criteria under factory conditions. Laminates from two sources were evaluated in conjunction with Sun XX high viscosity mineral oil and Cosden 015SH polybutene oil for high pressure type cables, and Dussek TC-2288N mineral oil, Shell P2 dedecylbenzene and Chevron DF-100 alkylbenzene for low pressure oil-filled cables. Swelling tests, infrared analysis, dissipation and dielectric measurements, impulse tests and a taping trial were performed. It was found that there is no appreciable difference in performance of both laminates when tested on model cables in a variety of oils. Both types exhibited superior aging characteristics vis-a-vis cellulose paper when tested with a variety of oils and at temperatures up to 105{degree}C. For pipe type ...

1983-08-01

93

From 33kV to 132kV cables: Norweb rises to the task  

Energy Technology Data Exchange (ETDEWEB)

Responsibility for the operation and maintenance of the bulk of the 132 kV cable network in England and Wales was transferred from the CEGB to the area boards in the 1970s. Norweb has successfully dealt with the increase in work using in-house expertise exclusively.

1982-09-17

94

Power cables: methods of defects localization; Cables d'energie: methodes de localisation des defauts  

Energy Technology Data Exchange (ETDEWEB)

The defects localization in power cables follows several steps: identification, pre-localization and precise localization. Pre-localization methods, other than echo-metry, are presented first: bridge methods, particular case of low voltage networks, future perspectives. Then, the precise localization methods are described: magneto-acoustic method, audible frequencies method. The particular case of underwater and high-voltage cables is considered too (oil and gas leaks detection). (J.S.)

2006-08-15

95

HVDC cable design logic for digital computers  

Energy Technology Data Exchange (ETDEWEB)

The design of High-Voltage, Direct-Current transmission cables insulated with oil-impregnated cellulose paper is constrained by the maximum temperature and the maximum steady-state and transient stresses (voltage gradients) that the cable insulation can reliably withstand over the desired operating lifetime. Because the electrical stresses in the insulation are related in a very complex fashion to temperature, applied voltage and cable geometry, iterative techniques are required to compute the values of these stresses. Digital computers are ideally suited for these iterative techniques. This paper presents the principal equations and logic needed to develop suitable computer programs.

1992-10-01

96

HPOF transmission-system economic-evaluation program. Final report  

Energy Technology Data Exchange (ETDEWEB)

This report describes the successful development of a computer program for the analysis of the economic, thermal, and rating characteristics of HPOF underground transmission cables with forced cooling. With this program cable engineers can interactively analyze self-cooled and forced-cooled HPOF cable design alternatives. The program computes cable thermal characteristics and discounted costs so that the impacts of changes in design parameters can be estimated. This report provides a review of the currently available HPOF design options that can be considered. The HPOF economic analysis program is written in FORTRAN IV and was developed for interactive operation.

1983-01-01

97

Back-up for high voltage cable pressurizing system  

Energy Technology Data Exchange (ETDEWEB)

A back-up system is provided for a pumping plant or a pressure reservoir system used to maintain insulating oil under pressure in high voltage submarine power cables which includes a gas driven membrane pump to insure a small outflow of oil at a rupture point in the power cable to prevent water from penetrating the cable. The proper operation of the membrane pump is insured by introducing degasified oil at the drive side of the pump during the stand-by and test modes of operation of the back-up system. 11 drawings.

1982-07-19

98

Ampacity calculations for mixed underground cable systems in the same ductbank  

Energy Technology Data Exchange (ETDEWEB)

The steady state ampacity is calculated for mixed electric power underground cable circuits in a single trench or ductbank. The methodology presented in this paper can be applied to any practical number of balanced, three phase circuits (each in trefoil, pipe or conduit) of different voltage classes, cable sizes, load currents and cable systems to located anywhere within a single trench or ductbank. The different thermal resistivities of the backfill or ductbank and the surrounding soil are taken into consideration. A practical example for 10 circuits in a trench is provided.

1994-12-31

99

Upgrading the ampacity of HPFF pipe-type cable circuits  

Energy Technology Data Exchange (ETDEWEB)

The upgrading of several 69 kV pipe-type cable feeders on the Potomac Electric Power Company (PEPCo) transmission cable system is discussed. The methods used for the ampacity calculation are described. The fluid circulation approach required to meet the feeder emergency load requirements are discussed. For the feeders that were in service for approximately 40 years, a system life evaluation was performed.

1994-12-31

100

Transient sheath overvoltages in armored power cables  

Energy Technology Data Exchange (ETDEWEB)

This paper is concerned with methods of limiting the build-up of transient voltages between sheath and armor in long armored power cables. Calculations by a frequency dependent cable model demonstrate that this voltage can be efficiently limited to an acceptable level by introducing sheath-armor bondings at regular intervals, or by using a semiconductive sheath-armor interlayer. The paper investigates the required minimum length between bondings, as well as the required conductivity of the sheath-armor interlayer if the use of bondings is to be avoided.

1996-07-01

101

New type of high voltage sea cable for floating installations; Ny type hoeyspent sjoekabel for flytende installasjoner  

Energy Technology Data Exchange (ETDEWEB)

Nexans has developed a new type of high voltage sea cable with metal barrier for dynamic application, suited for floating installations such as vessels, floating wind turbines or floating platforms. A brief presentation of the cable's design (ml)

2007-07-01

102

Marine cables for high power; Sjoekabel med hoeyere effekt  

Energy Technology Data Exchange (ETDEWEB)

A new type of impregnation jelly can be used instead of traditional oil may reduce the formation of cavities in marine high-voltage direct current cables. This provides a foundation for the development of cables with improved insulation and for higher power. This was a conclusion of the Norwegian ''EFFEKT''-project. Using the jelly reduces the size of the cavities substantially and no discharges seem to occur during formation, growth and collapse of cavities. It is also environmentally friendly, since there is no leakage of oil.

2001-07-01

103

Leak location in fluid filled cables using the PFT method  

Energy Technology Data Exchange (ETDEWEB)

A new method of pinpointing dielectric fluid leaks on pipe-type and self-contained cables using perfluorocarbon tracer (PFT) is presented. The method has successfully been used on the Con Edison transmission system to locate leaks of dielectric fluid on both types of cables. Application of the PFT technique does not require feeder deenergization and provides major advantages over the conventional method of freeze and pressure testing. Description of the method and results of field application are presented in the paper.

1999-01-01

104

HVDC power cable crossing Kii channel. Advanced technology to lay the submarine cable in two days; Kii suido wo yokogiru denryoku cable. Kaitei fusetsu wo futsuka de konasu shin`ei sochi  

Energy Technology Data Exchange (ETDEWEB)

Four HVDC (high voltage DC) {+-} 250kV submarine OF (oil-filled) cables are to be installed each capable of 1.4-million kW for one dipole channel and two returns for forwarding to Yura Switchyard a part of the power to be generated by a Tachibanawan coal-fired power plant to open in 2000. The first cable is now being laid. They are to cover a distance of 48km on the sea bottom, and their 190mm diameter is the largest in the world and this decreases the required number of cables for a reduction in the construction cost. The installation is executed by use of a dedicated cable laying ship loaded with cables. The ship is equipped with five thruster screws by adjusting which a cable is fed into the sea and laid on the bottom with high positional accuracy in all directions, and with a 10m-accurate DPS (Dynamic Positioning System) besides GPS (Global Positioning ...

1998-07-01

105

Fully synthetic taped insulation cables  

Energy Technology Data Exchange (ETDEWEB)

A high voltage oil-impregnated electrical cable with fully polymer taped insulation operable to 765 kV. Biaxially oriented, specially processed, polyethylene, polybutene or polypropylene tape with an embossed pattern is wound in multiple layers over a conductive core with a permeable screen around the insulation. Conventional oil which closely matches the dielectric constant of the tape is used, and the cable can be impregnated after field installation because of its excellent impregnation characteristics.

1984-12-11

106

French power for Jersey goes under water  

Energy Technology Data Exchange (ETDEWEB)

A proposed project by which the island of Jersy could buy electric power from France is discussed. The interconnector will be capable of transmitting up to 50MW. Included in the project will be 27 km of submarine cable and 23 km of underground cable. An oil-filled cable containing 120 mm diameter copper conductors and weighing 47 kg/m is used. Details of the installation and oil system are given.

1983-01-21

107

Evaluation of radiation resistance of cable connector material  

Energy Technology Data Exchange (ETDEWEB)

Radiation degradation of polycarbonate (PC) and polybutylene terephthalate (PBT) used as cable connector was evaluated using DSC, TGA, and mechanical properties. Glass transition temperature, melting temperature, 5% weight loss temperature, elongation at break, and tensile strength measurements were carried out for each of {gamma}-ray irradiated samples. In the results of those analyses, PC has radiation resistance better than PBT as a cable connector material.

2002-10-01

108

Calculating ac/dc resistance ratios for high-pressure oil-filled cable designs. Volume 2. Details of mathematical derivations. Final report  

Energy Technology Data Exchange (ETDEWEB)

Conventional methods for calculating electricity losses in pipe-type cable systems rely heavily on data measured in lower-voltage systems in the 1950s. With the new technique developed in this study, engineers can compute power losses more precisely for cables of various configurations and voltage ratings.

1985-04-01

109

Study for developing method of repairing interior of duct. Kanro naimen hoshu koho no kaihatsu kenkyu  

Energy Technology Data Exchange (ETDEWEB)

A hose lining process, used widely for underground service structures, such as for city gas, and water and sewerage pipes, was adopted to repair interiors of underground wire raceways, and improvements were made for power cable pipe use, including long size construction, inner diameter assurance, and flame retardation. The sealing hose as a lining material consists of a fabric layer woven by warps of polybutylene terephthalate (PBT) and wefts of combined PBT fibers and glassfibers, the fabric being coated with polyurethane resin on one side. The other side of the fabric is coated with heat hardening resin made of epoxy resin as the main ingredient and aromatic amine as the hardening agent to assure close adhesion of the sealing hose onto the pipe interior. Mimic raceways were used to verify the lining material for its abrasion coefficient, mechanical strength, wear resistance, water cut-off performance, chemical resistance, and shape retention ...

1991-03-25

110

Radiant emittance of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

An embodiment of a mercury-free fluorescent lamp combines a low pressure rare gas discharges with a phosphor having a quantum efficiency grater than one. The choice of the rare gas depends on a number of factors, one of which is the resonance transition energy. Less demand is placed the quantum efficiency of the phosphor for a lower energy resonance photon. Xenon has the lowest energy resonance transition of the stable rare gases at 8.5 eV (147 nm) and thus is a good candidate to study. The usefulness of a xenon-based discharge depends on the radiant emittance of the discharge at the resonance wavelength of 147 nm. The radiant emittance from a low pressure xenon positive column discharge is measured using two independent techniques. The first relies on the measurement of the resonance level density using absorption techniques. The effective decay rate of the resonance level is calculated using radiation trapping theory. The product of this ...

1994-12-31

111

Proposal for a commercial interconnection among the Hawaiian islands based on the results of the Hawaii deep water cable program  

Energy Technology Data Exchange (ETDEWEB)

After the successful completion of the development program of the 2000 m water depth HVDC Hawaii Deep Water Self Contained Fluid Filled Cable, the interconnection between Hawaii island and Oahu island is examined. Thermal, electrical, mechanical, hydraulic, corrosion, length aspects are developed for both fluid filled and paper impregnated (SOLID) cables which are foreseen in different portions of the approximately 250 km length connection. Considerations are also presented for the requirements of the cable ship: 12 m sheave diameter, 7000 t capacity for the rotating platform. The feasibility of manufacturing, transporting and laying such cables within a practical schedule is discussed in this paper.

1992-10-01

112

Evaluation of HVDC cables for the St. Lawrence crossing of Hydro-Quebec 500 kV DC Line. Part 1; Dielectric and accelerated aging tests on prototypes  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the dielectric and accelerated aging tests on prototype {plus minus}500 kV dc oil-filled self-contained cables. The extensive test program was required to evaluate the High-Voltage cables for the St. Lawrence river crossing of the {plus minus}500 kV Quebec-New England HVDC power transmission system. The paper relates the main elements of the test program. It describes the required insulation levels, the characteristics of the cables supplied by three different manufacturers, as well as the cables' installation for the type tests and accelerated aging tests. Details of the test program and procedures followed to carry out the tests are given. Findings of the tests are also reported.

1992-04-01

113

Honshu-Shikoku linking transmission cable building plan. ; Development of power sources. Honshi renkei sodensen kensetsu keikaku. ; Dengen kaihatsu  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a Honshu-Shikoku linking transmission cable building plan and its technical features. The Chugoku District and the Shikoku District are supplied with power currently by the Chugoku-Shikoku trunk line of 220,000 volts. To cope with the anticipated power shortage, a plan was established to install power cables for 500,000 volts on the Honshu-Shikoku connecting bridge. The plan calls far an installation length of 127.4 km and a transmission capacity of 1.2 million kW per line. The cable installation on the Seto Bridge was completed already, the construction is now in the peak period for building steel towers on the land sections, and laying overhead cables and underground cables. Commencement of the operation is scheduled 1994 on one liner, and 2000 on two lines. The technical features include the Japan's first large-capacity, long-distance underground ...

1992-03-01

114

Oil-filled, multi-core cable with at least one conductor differing from others  

Energy Technology Data Exchange (ETDEWEB)

This patent discloses an oil-filled, multi-core, electric cable having three cores within a metal sheath suitable for underwater applications. Each core has a conductor surrounded by insulation and has substantially the same outer dimensions as the other cores. One conductor is made of copper and has a central oil duct. The other conductors are made of stranded aluminum wires in side-by-side and contacting relation and the ratio of the cross-sectional area of the metal of the copper conductor to the cross-sectional area of the metal of each aluminum conductor is the reciprocal of the ratio of the electrical conductivities thereof. One object of this invention is that of overcoming the drawbacks existing in the known oil-filled, multi-core cables, i.e. to provide cable which, in case of a rupture of the cable sheath, has fairly small leakages of insulating, fluid oil from the cable ...

1987-02-03

115

Laboratory development of +- 600 kVdc pipe type cable systems  

Energy Technology Data Exchange (ETDEWEB)

In 1976, the US Department of Energy and New York State - ERDA granted a contract for the development of a +-600 kV dc underground transmission cable system looking to inevitable future requirements in the US for economic, high-capacity, long-distance underground transmission linking remote generating stations to metropolitan load centers. This project was comprehensive and dealt with three separate system components, i.e., cable, splice, and terminals. In each instance, for each component, development required an intensive R and D effort, focused on the following categories: insulating materials, model testing, design of full-scale prototype, manufacturer of prototype, and laboratory development testing. Insulating papers and oils were selected, and model studies performed, for both self-contained type and pipe type oil-filled cables. However, only the pipe cable design was finally designated for ...

1982-07-01

116

Increasing pipe-cable section lengths. Final report  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the results of an experimental program which developed a needed reliable data base on modern pipe-type cable construction from which designers can knowledgeably consider maximizing cable pulling lengths with resulting cost savings. The program comprised evaluations of available commercial constructions over the range of conductor sizes (both copper and aluminum) and insulation thicknesses in general utilization. The work focussed on determining the cable's performance under the three mechanical stress modes to which the cable is subjected during installation; (a) tension and elongation, (b) torsion and (c) sidewall (bearing) pressure in bends. Additionally, the program included experimentation to determine the effective coefficient of friction of the various combinations of modern skid wire materials and pipe filling oils used as lubricants with the ...

1983-03-01

117

Cable-to-air terminations: The cable system's second weakest link  

Energy Technology Data Exchange (ETDEWEB)

Transmission terminations available today are very reliable, but they need to be. In the field, they are continually exposed to pollution and extremes of ambient temperature. In many cases, they are in the rifle sights of vandals. In contrast, cable joints - often cited as the weakest links from an electrical viewpoint - are generally protected from physical damage underground and many of the short cable systems being installed in the US today can be built without joints. All cable systems need terminations - mostly to air-insulated equipment. At 69 through 138 kV, there is intense competition among manufacturers to supply terminations for solid-dielectric cable that are low in cost, reliable, and require a minimum of skill to install. Some utilities are looking also for terminations that fit a range of cable sizes; terminations that do not contain liquid that can leak out; and ...

1994-12-01

118

Optical properties of fly ash. Volume 2, Final report  

Energy Technology Data Exchange (ETDEWEB)

Research performed under this contract was divided into four tasks under the following headings: Task 1, Characterization of fly ash; Task 2, Measurements of the optical constants of slags; Task 3, Calculations of the radiant properties of fly ash dispersions; and Task 4, Measurements of the radiant properties of fly ash dispersions. Tasks 1 and 4 constituted the Ph.D. research topic of Sarbajit Ghosal, while Tasks 2 and 3 constituted the Ph.D. research topic of Jon Ebert. Together their doctoral dissertations give a complete account of the work performed. This final report, issued in two volumes consists of an executive summary of the whole program followed by the dissertation of Ghosal and Ebert. Volume 2 contains the dissertation of Ebert which covers the measurements of the optical constants of slags, and calculations of the radiant properties of fly ash dispersions. A list of publications and conference presentations ...

1994-12-01

119

HVDC submarine power cables systems state of the art and future developments  

Energy Technology Data Exchange (ETDEWEB)

The paper begins with an introduction on the reasons that lead to the use of HVDC submarine cable links. The main aspects for the choice of direct current are presented as well as the advantages deriving from the utilization of submarine cables. The second part is dedicated to a discussion on the various type of insulation that could be used in power cables and their possible application to HVDC submarine cables. In the following there is a description of the main characteristics and technical details of some particular project that at present time (1995) are in progress. Two projects are briefly presented: Spain-Morocco, a 26 km long interconnection for the transmission, in a first phase, of 700 MW from Spain to Morocco at 400 kV a.c. by means of three cables, plus one spare, of the fluid filled type. The cables are designed for a future change to d.c. 450 kV, ...

1995-12-31

120

Repair of failed 138kV pipe type cable line  

Energy Technology Data Exchange (ETDEWEB)

On February 9, 1995 ComEd experienced a pipe type cable failure on 138kV line 13717. Line 1737 is a bulk power transmission cable circuit connecting The Fisk and Crawford generating stations located within city limits. The line is approximately 4.5 miles long and was originally installed in 1975. This line is forced cooled, has 2,500 KCMIL copper conductors with 505 mils of paper insulation in an 8 inch pritec coated steel pipe. The splices are constructed with Voltalit castings. The failure occurred approximately 3,500 feet from Crawford Station. It was easy to locate the failure since the cable joint casing was breached resulting in the loss of approximately 2,600--2,700 gallons of dielectric fluid. Upon field examination B Phase was determined to have failed. The failure occurred 12 inches inside the casing in an area where it was impossible to install a long connector or add an additional short length of ...

1996-11-01

121

Calculation of the transmission capacity of long-distance EHV single-core submarine cable systems  

Energy Technology Data Exchange (ETDEWEB)

A general calculation method for the analysis of transmission capability of a long-distance single-core ac submarine cable system is presented. The method is based on modal transformation of voltages and currents in multiconductor cable systems. Using this method, numerical calculations on 500 kV submarine cable systems have been performed with particular reference to the effect of the distance between bonds connecting metallic sheath, outer conductor and armor on the transmission capacity of the system. It was clarified that the transmission capacity of the system increased with decreasing bond intervals. Examination of the current distributions between various conductors along the length showed that this increase of transmission capacity was mainly due to the dispersion of the charging current into the metallic sheath, outer conductor and armoring at the bonding points. Analytical results for the transmission capacities ...

1981-11-01

122

Application of the CFAST zone model to the Fire PSA  

Energy Technology Data Exchange (ETDEWEB)

The integrity of the cables located in the target room is very important in the Fire PSA, because the CDF and CCDP are changed according to the results of a cable integrity that depends on the surrounding gas temperature. The conservative assumptions used in the Fire PSA typically specify that all of the equipment and cables of a room would fail when a fire happens in the room. But the realistic assessment of a fire risk by using a fire simulation tool has become necessary in the Fire PSA as described in the ANS Fire PRA Standard. This paper evaluates the cable integrity of eight pump rooms in the nuclear power plant by using the CFAST zone fire model. The upper layer gas temperature of each room is estimated, and an analysis based on the results of model simulations is used to judge the cable integrity. According to the analysis results, the integrity of the ...

2010-10-15

123

Multiple stress aging of solid-dielectric extruded dry-cured insulation systems for power transmission cables  

Energy Technology Data Exchange (ETDEWEB)

A detailed examination of the aging processes that may take place in solid-dielectric extruded-type high voltage transmission cables under dry conditions is presented. Particular emphasis is placed on the aging process as affected by the separate and simultaneous action of four main aging factors, namely the electrical, mechanical and thermal stresses, and the physical and chemical environment. A number of pertinent aging models are considered and their validity and applicability to accelerated aging tests on solid-type transmission cables are discussed.

1994-01-01

124

Field validation of cable monitoring and rating system (CMARS) laboratory model. Semi-annual report, 1 May 1979-31 December 1979  

Energy Technology Data Exchange (ETDEWEB)

One year of research on validating the performance of the Cable Monitoring and Rating System (CMARS) is reported. The performance testing was conducted on underground 230-kV and 345-kV pipe type cable circuits owned by the New Jersey Public Service Electric and Gas Co. Laser temperature monitoring systems and a data acquisition system were installed. Software installation and development is discussed. The CMARS testing program is described. (LCL)

1980-01-01

125

Development of radial-flow type internally oil-cooled oil-filled cable  

Energy Technology Data Exchange (ETDEWEB)

A radial-flow type internally oil-cooled oil-filled cable has been developed. This system is characterized in that the oil flows radially through the paper insulation. The thermal resistance of the insulation is equivalently decreased by the radial-flow. The decreased thermal resistance as well as the cooling effect of the oil flow in the central oil duct and the outer oil duct under an aluminum sheath increase the current capacity. A calculation method of cooling characteristics is introduced. The stability of the cable and accessories was confirmed through initial electrical tests and a long-term field test.

1988-01-01

126

Correlation between Magnetic Field Quality and mechanical components of the Large Hadron Collider Main Dipoles  

CERN Document Server

The homogeneity of the magnetic field in the LHC dipoles strongly depends on the correct position of the superconducting cables: this is related to the quality of the dipole components, such as the dimension of the coil spacers (copper wedges), of the cable and of the collars. The performance in operational conditions is also affected by the magnetization of the cables. In this work, we analyse the measurements of these quantities during the production of the 1276 LHC dipoles, their trends, and the relation to the measured magnetic field. A novel mtehod to locate electrical shorts based on the analysis of magnetic measurements is also presented, and applications to 15 dipoles reascued during the production is given.

2006-01-01

127

Axiomatic Design Approach for a Reactor Head Structure Assembly  

Energy Technology Data Exchange (ETDEWEB)

Korea Atomic Energy Research Institute (KAERI) has been developing the integral reactor. The reactor head structure assembly (RHSA) is the structure installed over the reactor cover. Due to the characteristics of an integral reactor, there are many instrument cables and power cables coming out from the reactor cover and main components. The RHSA provides an interface location to connect these cables from Architecture Engineer (AE) and System Designer (SD). It also prevents a pipe whip and it prohibits instruments from becoming missiles. In this research, the axiomatic design approach for the RHSA is performed.

2006-07-01

128

Study of the Effects of Ambient Conditions Upon the Performance of Fan Powered, Infrared, Natural Gas Burners  

Energy Technology Data Exchange (ETDEWEB)

Fourier transform infrared spectroscopy is a simple, fast, reliable and nondestructive analytical method. By using the method developed in Clark Atlanta University, consistent and reliable infrared spectral results can be obtained. An accurate radiant energy can be calculated from these infrared spectra by using a blackbody as the calibration standards. By means of the specially-designed-and-lab-made sampling inlet and the Horiba gas analyzers, the compositions of CO{sub 2}, CO, UCH, NOx and O{sub 2} etc. from the combustion exhaust gases have been on-line accurately analyzed. The commercial natural gas IR burner performed differently in the different conditions. For the methane-air combustion, at the equivalence ratio {Phi} = 1, the IR burner produced its maximum radiation efficiency, {approximately}31.4%, and the concentration of CO{sub 2} reached its maximum value, {approximately}10.7%. In the fuel-lean region, the O{sub 2} concentration in the emission gas ...

1997-03-31

129

Physical mechanism in the free-electron laser  

International Nuclear Information System (INIS)

In this paper some physical mechanisms are described, which determine some new free-electron laser configurations. These mechanisms comprise some physical effects of the radiant emission of an electron beam at the interaction with the medium it is crossing. They are based on the Cherenkov effect, Smith-Purcell effect, optical klystron, Rumakhov effect and limited interaction effect. (Author).

1992-09-21

130

ch4  

Science.gov (United States)

Earlier studies had concluded that the preferred direction of the rocket nozzle should ..... Center had to redesign the sensor canisters, brackets and cable supports. ... depending on inspection of the quality of the incoming pictures in real-time. ...

131

Test of use of MN-4 oil in 110 to 220 kV cable lines  

Energy Technology Data Exchange (ETDEWEB)

Beginning in 1972 low-pressure cables filled with MN-4 oil produced by the Yaroslav Petroleum Processing Plant arrived at the Leningrad Cable Network of the Leningrad Rayon Power Administration. Lines formed with these cables have been successfully used. The parameters of the oil in them have not changed with respect to the values present when the lines were placed in operation. However, from here on filling in of the 110 to 220 kV input lines of low and high pressure will be accomplished with MN-4 oil produced by the Gorkiy Petroleum Processing Plant. Because petroleum from various fields and the properties of the oil produced from it are unlike, samples were taken from some elements of the lines filled in with MN-4 oil. The results of the tests are described.

1980-09-01

132

State of the art in installation of buried HV and EHV cables; Etat de l'art sur la pose des cables souterrains a haute et tres haute tension  

Energy Technology Data Exchange (ETDEWEB)

CIGRE has set up a new working group - Insulated High Voltage Cables - under the auspices of Study Group 21. The working group will examine the various techniques used for the installation of HV and EHV cables and the design parameters to be applied. Twelve installation techniques are known, but only three of these ar used at present. Following an international study carried out by the working group, a clear picture of the state of the art in 1998 has emerged. It has also been possible to identify future trends in the design of buried circuits. (authors)

2000-05-01

133

Large eddy simulation based fire modeling applications for Indian nuclear power plant  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: The Nuclear Power Plants (NPPs) are always designed for the highest level of safety against postulated accidents which may be initiated due to internal or external causes. One of the external/internal causes, which may lead to accident in the reactor and its associated systems, is fire in certain vital areas of the plant. Conventionally, the fire containment approach and/or the fire confinement approach is used in designing the fire protection systems of NPPs. Indian NPPs (PHWRs) follow the combined approach to ensure plant safety and all newly designed plants are required to comply with the provisions of Atomic Energy Regulatory Board (AERB) fire safety Guide. In respect of older plants, the reassessment of adequacy of fire safety provisions in the light of current advances has becomes essential so as to decide upon the steps for retrofitting. Keeping this in mind the deterministic fire hazard analysis was carried out for the Madras Atomic Power ...

2005-07-01

134

Application of the CFAST zone model to the Fire PSA  

British Library Electronic Table of Contents (United Kingdom)

The integrity of the cables located in the target room is very important in the Fire PSA, because the CDF and CCDP are changed according to the results of a cable integrity that depends on the surrounding gas temperature. The conservative assumptions used in the Fire PSA typically specify that all of the equipment and cables of a room would fail when a fire happens in the room. But the realistic assessment of a fire risk by using a fire simulation tool has become necessary in the Fire PSA as described in the ANS Fire PRA Standard. This paper evaluates the cable integrity of eight pump rooms in the nuclear power plant by using the CFAST zone fire model. The upper layer gas temperature of each room is estimated, and an analysis based on the results of model simulations is used to judge the c...

2010-01-01

135

Adaptation of an air-dielectric RF cable for use as an oil-filled high voltage pulse transmission line  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the specifications, conceptual design, prototype testing and operating experience of an oil-filled high voltage pulse transmission cable adapted from commercially available air-dielectric RF components. Lawrence Livermore National Laboratory's Advanced Test Accelerator (ATA) requires a method of transmitting 250kV, 70 nanosecond pulses from the power conditioning equipment to the accelerator. The oil-filled cable approach was chosen over alternative concepts because of its high voltage holding capacity, long life and flexibility. The criteria for cable and connector design are discussed. The results of prototype testing and performance of the final design are presented.

1984-11-01

136

Underground cables as an alternative to overhead lines. A comparison of economic and technical aspects of voltages over 22 kV  

Energy Technology Data Exchange (ETDEWEB)

The report presents technical and economical aspects of underground cables compared to overhead lines in Norway in high voltage transmission systems above 22 kV. The economical comparison between the two options includes capital costs of installation (investment costs), maintenance costs and costs of electrical losses. The main technical issues discussed are reliability and flexibility. 35 refs., 23 figs., 29 tabs.

1994-07-11

137

New advances in mitigating environmental impact of pipe-type cables  

Energy Technology Data Exchange (ETDEWEB)

Through a comprehensive and aggressive research program Consolidated Edison Company of New York, Inc. (Con Edison) has designed, developed, and installed several new products to address the environmental impact of dielectric fluid from pipe-type cable systems. These include: On Line Leak Detection, Leak Location, Retractable Flow Direction Indicator, Full Stop Joints, and Transition Joints. This paper describes the application of the aforementioned products on the Con Edison underground transmission system.

1999-04-01

138

Mortality and incidence of cancer among oil exposed workers in a Norwegian cable manufacturing company. Part I. Exposure conditions 1920-79.  

UK PubMed Central (United Kingdom)

Heavy high viscosity oils, transformer oils, and very light low viscosity oils have been used in a Norwegian company in the impregnation, sheathing, and installation of paper insulated cables. The aim...Full Text Available

1988-09-01

139

Construction - laying and installation techniques for extruded and self contained fluid filled cable systems  

Energy Technology Data Exchange (ETDEWEB)

The focus of general public concern on the environment results in the use of underground lines being considered since they offer alternative or interesting complementary solutions for the bulk transmission of electrical energy. This leads to the installation of underground cables in some areas, where overhead lines would automatically have been considered in the past.

2001-07-01

140

Barrier filter for fluorescence microscopy of strongly autofluorescent plant tissues. Application to actin cables in Chara.  

Science.gov (United States)

A liquid barrier filter for use in fluorescence microscopy of strongly autofluorescent plant tissues is described. The filter consists of a methanol solution of cupric chloride and ferric chloride and isolates fluorescein fluorescence from the strong red autofluorescence of photosynthetic plant tissues. Subcortical actin cables in the giant alga Chara are being visualized through use of this filter together with heavy meromyosin labeling. PMID:90068

1979-05-01

141

10 MWe Solar Thermal Central Receiver Pilot Plant: solar facilities design integration. Plant electrical equipment installation. Construction package No. 11 (RADL Item 7-35)  

Energy Technology Data Exchange (ETDEWEB)

Installation of the electrical equipment at the Barstow Solar Pilot Plant is the concern of this construction package. Technical specifications for power and instrument cables, meteorological instruments, and control cables are defined. The documentation requirements are briefly discussed.

1980-07-01

142

Dalia integrated production bundle (IPB): an innovative riser solution for deep water fields  

Energy Technology Data Exchange (ETDEWEB)

The Dalia field is located 210 km north west of Luanda (Angola), about 140 km from shore in 1400 meter water-depth. It was the second major discovery out of 15 made in the block 17 operated by Total. The Dalia Umbilical, Flow lines and Risers EPCI Contract was awarded in 2003. The sea-line network to connect and control the 71 wells and 9 manifolds consist of the following: 40 km of insulated pipe in pipe (12 inches into 17 inches) production flow lines; 45 km of 12 inches water and gas injection lines; 6 off 1.7 km flexible water and gas injection risers; 8 off 1.65 km flexible Integrated Production Bundle (IPB) risers; 75 km of control umbilicals. The flow assurance and associated insulation requirement of the production transport system was one of the main challenges of the project. With a crude temperature of 45 deg C at the wellhead and the required minimum temperature of 35 deg C on arrival at the FPSO, this problem was complex. Understanding that, due to the Joule Thompson ...

2008-07-01

143

Using fiber optic sensors to protect intake, outflow, and other environmentally exposed openings  

Energy Technology Data Exchange (ETDEWEB)

This paper reports on the protection of opening that are exposed to the environment in nuclear facilities which presents an almost overwhelming engineering challenge. Intakes and outflows must permit the passage of large volumes of air or water without impeding their flow, and they are often exposed to corrosive salt and chemicals. An intrusion detection sensor that is intended to protect these openings must be capable of operating reliably under environmentally harsh conditions, and at the same time either provide a physical delay barrier or attach to an existing barrier. A new fiber optic sensor technology has now been developed specifically for protecting environmentally exposed openings. This sensor uses a fiber optic cable embedded in a neoprene rubber frame which is reinforced with Kevlar threads or braided steel cable. The sensor is configured in a mesh pattern with openings sufficiently large to permit air or water to flow unimpeded, ...

1991-01-01

144

Study of degradation diagnosis for low voltage cable aged by thermal and radiation with time domain dielectric spectrometer  

International Nuclear Information System (INIS)

Non-destructive methods of diagnosis for detecting cable degradation by aging are being studied recently for improvement of electric wires and cables. This study examines degradation behaviors of cable sheath and insulation by combined accelerated aging tests applying thermal and radiation stresses simultaneously using a typical low voltage cable. According to experiments, elongation of cross-linked polyethylene insulation deteriorated at a faster rate than PVC sheath did under low doses below 50 Gy/h. Therefore, measurements using a time domain dielectric spectrometer (TDS) were carried out for the purpose of developing a method of degradation diagnosis of insulation. It was found that values of tan#delta# measured at very low frequencies below 0.1 Hz increase in pace with degradation of insulation reflecting the level of degradation more effectively than those measured at frequencies around the ...

2000-05-01

145

Safety gas management system utilizing telephone cable  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the safety gas management system utilizing public telephone cables. Buyo Gas Co., Ltd. has installed about 100 governors for exclusive-use or use in the districts to control the gas supply to the consumers. A gas safety management system has been developed. This system consists of a pressure sensor, the terminals of gas leak alarms, and their masters. The features lie in that the system can utilize public cables, is operative at interruption of power service, can correspond to emergency situations, serves to save the cost, and can display the data constantly. For electric facilities in a governor room and the NTT cable service work, sufficient agreement with the possessor is required. In the case of non-utility electric facilities, some restrictions are imposed on the cable work for laying from privately-owned transformers, etc. Insurance for the facilities is necessary to prepare ...

1988-02-10

146

Resistive cryogenic cable economic-viability evaluation. Final report, Volume I  

Energy Technology Data Exchange (ETDEWEB)

This report presents a reassessment of the design of Resistive Cryogenic Cable Systems with regard to dielectric material selection, thermal insulation selection, conductor design, and refrigeration subsystem design. An algorithm using test data generated as part of the program and available from the literature was developed and used to assess the driving parameters for system cost analysis. The results of this cost sensitivity analysis are presented. An electric utility, Public Service Electric and Gas of New Jersey (PSE and G), performed an economic viability evaluation comparing two selected Resistive Cryogenic Cable Systems to a conventional cable system (high pressure oil-filled). The comparison was made for a 35-mile network application on the PSE and G transmission system scheduled to be placed in service in 1995. Consideration was given to equipment capital, installation, and operating costs. It was concluded that a ...

1980-03-31

147

New technique: recovery of cables without trenching works; Verfahren zur grabungsfreien Bergung von Kabeln  

Energy Technology Data Exchange (ETDEWEB)

Flow Tex and ABB Energiekabel GmbH have developed a technique which allows the recovery of cables without requiring any trenching works. The new technique was successfully used for the first time for a pilot project in 1995. The authors report on two recent recovery projects (1998) in which an optimised technology was used for recovering a total of 1 500 m system length of 110 kV low-pressure oil-filled cables in Stuttgart and Munich on very different conditions. The authors describe the operational experiences with the cable connections and highlight the background stipulating the removal of the cables. (orig.) [Deutsch] Ein Verfahren zur grabungsfreien Bergung von Kabeln, gemeinsam entwickelt von FlowTex und ABB Energiekabel, wurde erstmals in einem Pilotprojekt 1995 mit Erfolg eingesetzt. Die Verfasser berichten ueber zwei Bergungsprojekte, bei denen 1998 mit der optimierten Technik in Stuttgart und ...

1999-03-22

148

Cost reduced inspection concept of PE/XLPE medium voltage cables; Kostensparende Zustandsanalyse an PE-/VPE-isolierten Mittelspannungskabeln  

Energy Technology Data Exchange (ETDEWEB)

The microelectronic cable diagnosis is a substantial tool to determine destruction free the residual strength and the lifetime of laid PE/XLPE medium voltage cables. Fundamentals of the ageing diagnosis and a cost reduced inspection concept are the `Isothermal-Relaxation-Current` Analysis and the Neuro-Fuzzy evaluation software. These new tools are able to determine the ageing status of the investigated cable without any references. The authors also show that the test breakdown during the assessment of the ageing status of criterial systems can be reduced by this approach. The cable diagnosis equipment KDA is also useful for the steering of investment as well as for preventive maintenance. (orig.) [Deutsch] Die zerstoerungsfreie dielektrische Kabeldiagnostik kann heute einen wesentlichen Beitrag zur Bestimmung der Restfestigkeit und der Restlebensdauer eines PE/VPE-isolierten Mittelspannungskabels ...

1997-12-15

149

Calculating ac/dc resistance ratios for high-pressure oil-filled cable Designs. Volume 1. Designer's guide. Final report  

Energy Technology Data Exchange (ETDEWEB)

Using electromatic field theory, a new method is developed for calculating alternating current in power cables installed in pipes of carbon steel (magnetic pipes). The technique for evaluating these losses is based on the method of images which replaces complicated distribution of currents in the system with a sequence of thin conductors. The method not only gives a mathematical framework for the solution of alternating current losses, but it also gives the underlying physical picture of effects contributing to these losses. Skin effect, proximity effect and losses due to the pipe are calculated separately. For the first time, the increase of losses in the conductors, when the cables are placed in a magetic pipe, are analyzed mathematically. Good agreement is obtained between the result of calculations and the experimentally determined ac-dc resistance ratios for pipe-type cables with concentric stranded copper conductors ...

1985-04-01

150

500 kV oil-filled cable installed on bridges  

Energy Technology Data Exchange (ETDEWEB)

The 220 kV Ch{bar u}si Trunk Line, now transmitting a maximum of 300 MW of electricity between the Ch{bar u}goku area of Honsh{bar u} and Shikoku island, is expected to be inadequate in the 1990's due to the rise in electrical demand. Therefore, to strengthen this interconnection, a new 500 kV transmission line was proposed. The most significant feature of this transmission line is the installation of 500 kV cables along the bridges (the Seto Ohashi Bridge) which span the Inland Sea (Seto). This is the first 500 kV long-distance transmission cable line. It is also the first large-scale cable line in the world installed along various types of bridges (ten bridges; route length of the bridge portion approximately 8 km). This paper gives an outline of the Honsh{bar u}---Shikoku interconnecting transmission line and also presents some technical features concerning 500 kV cables.

1990-04-01

151

TASK 2.5.4 DEVELOPMENT OF AN ENERGY SAVINGS CALCULATOR  

Energy Technology Data Exchange (ETDEWEB)

California s major energy utilities and the California Energy Commission (CEC) are seeking to allocate capital that yields the greatest return on investment for energy infrastructure that meets any part of the need for reliable supplies of energy. The utilities are keenly interested in knowing the amount of electrical energy savings that would occur if cool roof color materials are adopted in the building market. To meet this need the Oak Ridge National Laboratory and the Lawrence Berkeley National Laboratory (LBNL) have been collaborating on a Public Interest Energy Research (PIER) project to develop an industry-consensus energy-savings calculator. The task was coordinated with an ongoing effort supported by the DOE to develop one calculator to achieve both the DOE and the EPA objectives for deployment of cool roof products. Recent emphasis on domestic building energy use has made the work a top priority by the Department of Energy s (DOE) Building Technologies Program. The Roof ...

2010-03-01

152

Radiant{trademark} Liquid Radioisotope Intravascular Radiation Therapy System  

Energy Technology Data Exchange (ETDEWEB)

RADIANT{trademark} is manufactured by United States Surgical Corporation, Vascular Therapies Division, (formerly Progressive Angioplasty Systems). The system comprises a liquid {beta}-radiation source, a shielded isolation/transfer device (ISAT), modified over-the-wire or rapid exchange delivery balloons, and accessory kits. The liquid {beta}-source is Rhenium-188 in the form of sodium perrhenate (NaReO{sub 4}), Rhenium-188 is primarily a {beta}-emitter with a physical half-life of 17.0 hours. The maximum energy of the {beta}-particles is 2.1 MeV. The source is produced daily in the nuclear pharmacy hot lab by eluting a Tungsten-188/Rhenium-188 generator manufactured by Oak Ridge National Laboratory (ORNL). Using anion exchange columns and Millipore filters the effluent is concentrated to approximately 100 mCi/ml, calibrated, and loaded into the (ISAT) which is subsequently transported to the cardiac catheterization laboratory. The delivery catheters are modified ...

1998-01-16

153

Renovation of Isogo thermal power plant of Electric Power Development Co. with new and old systems near to each other; Dengen Kaihatsu (kabu) Isogo karyoku hatsudensho koshin koji shinsetsu hosui kanro to kisetsu hatsudensho OF cable no kinsetsu seko  

Energy Technology Data Exchange (ETDEWEB)

This is a build-and-scrap-and-build job, in which a new No. 1 generator is constructed while the existing plant stays in operation in the same site. Since interference between the new and the existing systems are unavoidable in such work, protection is sufficiently provided and measurements are frequently performed when the work comes to involve important structures positioned close to each other, such as the existing No. 1 and No. 2 OF (oil-filled) cables transmitting power from the existing power plant to Minami-Yokohama Substation of Tokyo Electric Power Co., Ltd., and the newly planned discharge channel or the existing covered sewerage and the newly planned discharge outlet. Now that the newly planned discharge channel intercepts the OF cables at three places and is installed to pass under the existing cable duct, it once happened that the duct supporting piles were severed for the cables to suspend ...

1998-09-05

154

Solid particle receiver experiments: velocity measurements  

Energy Technology Data Exchange (ETDEWEB)

Laser Doppler velocimetry and other photometric techniques are evaluated for measuring the average particle velocity in an ensemble of free-falling particles. The ability to obtain measurements in the presence of a radiant flux as high as 0.6 MW/m/sup 2/ was part of the evaluation. Optically dissimilar particles with diameters ranging from 0.1 mm to 1 mm were used in the study. Experimental results indicate that ensembles of particles do not behave as single isolated particles. The particle motion is dependent on particle volume fraction, and is quite unstable for falls greater than one meter.

1984-10-01

155

Solid particle receiver experiments: velocity measurements  

Science.gov (United States)

Laser Doppler velocimetry and other photometric techniques are evaluated for measuring the average particle velocity in an ensemble of free-falling particles. The ability to obtain measurements in the presence of a radiant flux as high as 0.6 MW/m/sup 2/ was part of the evaluation. Optically dissimilar particles with diameters ranging from 0.1 mm to 1 mm were used in the study. Experimental results indicate that ensembles of particles do not behave as single isolated particles. The particle motion is dependent on particle volume fraction, and is quite unstable for falls greater than one meter.

1984-10-01

156

Weld integrity of the superconducting cable aluminium jackets of W7-X  

British Library Electronic Table of Contents (United Kingdom)

The Wendelstein 7-X (W7-X) modular stellarator is under construction at the Max-Planck-Institut fur Plasmaphysik in Greifswald, Germany. The W7-X magnet system contains 70 coils made up from helium cooled superconducting cables in aluminium alloy (EN AW-6063) jackets. Several hundred connections of the jacket to the cable joints are made by aluminium-to-aluminium welds. Due to geometrical and thermal boundary conditions these welds cannot be accomplished free from defects. Microscopic analyses of the welds show that a variety of small flaws such as cracks and pores develop during welding. The welds have thus to be dimensioned accordingly, and appropriate weld qualification, investigation and testing has to be done in order not to jeopardise the structural integrity and leak tightness. The ...

2009-01-01

157

Oil-filled cable surveillance system using newly developed optical fiber gas sensor  

Energy Technology Data Exchange (ETDEWEB)

A new surveillance system for Oil-Filled cable, which can provide continuous monitoring, using a newly developed optical gas sensor that can detect the concentration of the gas dissolved in the oil with extremely high sensitivity has been developed. It was proved that the degree of deterioration of the insulating oil can be detected by measuring C{sub 2}H{sub 2} and CH{sub 4} by investigating the relation between the degree of deterioration and amount of combustible gas generated. In order to detect extremely small amounts of gas, a new gas detecting method using absorption line of the gas using a frequency modulated technique has been developed. The gas detection ability was also confirmed by examination using a 66 kV of cable and the possibility of detection at an early stage is expected.

1996-04-01

158

Final report: technical contributions to the development of incipient fault detection/location instrumentation  

Energy Technology Data Exchange (ETDEWEB)

The transmission of electrical energy by use of underground cables is increasing. Fault location techniques have certain limitations; incipient fault detection and location would help reduce the maintenance cost of these lines as well as improve the reliability of service. The report discusses some test results related to RF-probing techniques applied to high-voltage transmission lines. The high-frequency losses and attenuation in high-voltage cables places certain ultimate limitations on RF-probing techniques for incipient fault detection. Time-domain reflectrometry methods were employed to assess the RF-transmission properties of high-voltage cables at frequencies as high as 6 GHz. Fast-Fourier-transform deconvolution was used to obtain loss measurements as a function of frequency. The loss mechanisms were identified. The measurement hardware and methods are discussed as well as analysis approach leading to the ...

1986-04-01

159

Evaluation of improvements in the installation of rural underground transmission lines: Final report  

Energy Technology Data Exchange (ETDEWEB)

This report presents the results of an investigation into currently used methods for installation of underground high voltage power transmission cable, and offers recommendations for potentially improving these methods. Suggested enhancements cover the emplacement of both high pressure oil filled (HPOPT) pipe type and self contained oil filled (SCOF) cable systems. Cost comparisons of conventionally installed cable systems versus systems using proposed techniques and equipment are developed for a specific site selected for study. The report also documents the test results of laboratory experiments conducted to demonstrate the feasibility of using interference fit pipe couplings in place of welded pipe joints. 10 refs., 31 figs., 15 tabs.

1987-10-01

160

Environmental aspects concerning medium- and highvoltage cables; Umweltfragen bei Mittel- und Hochspannungskabeln  

Energy Technology Data Exchange (ETDEWEB)

Environmental compatibility is nowadays a very important part in the case of planing, construction, operation and maintainance of cable systems. A lot of laws and orders have to be observed. Some new aspects concerning the removal of oil filled cables and the consideration of electromagnetic fields even for cabels will be presented. (orig.) [Deutsch] Der Umweltschutz ist heute unverzichtbarer Bestandteil der Planung, Bau, Betrieb und Instandhaltung von Kabelanlagen. Zahlreiche Gesetze und Verordnungen sind hierbei zu beachten. Der Verfasser stellt einige Neuerungen im Zusammenhang mit dem Ausbau und Oelkabeln vor und erlaeutert die auch bei Kabeln zu beruecksichtigenden elektromagnetischen Felder. (orig.)

1997-09-22

161

Development of flexible joint for 500kV Al-sheathed O. F. cable  

Energy Technology Data Exchange (ETDEWEB)

This paper reports on a flexible dimensionaly flush joint for 500kV aluminum-sheathed oil-filled cables capable of being assembled, pulled an installed in a similar manner to cables at site which has been developed. This joint is intended for use at intermediate points on long bridges or tunnels where local assembly and installation of conventional joints would be difficult. In developing the joint various novel and original techniques have been employed, including the flexible flush jointing of segmental conductors, the flexible jointing of paper insulation by a combination of wrapping-back and stepping methods, plus on-site aluminum sheath corrugating and sealing methods.

1992-10-01

162

Building connections - Transition from TN-C to TN-S five-core building connection cable solves problems; Hausanschluss: Wechsel von TN-C auf TN-S  

Energy Technology Data Exchange (ETDEWEB)

This article discusses the use of five-core cables to provide utility customers with the best possible prerequisites for trouble-free operation of electrical installations and equipment. The TN-S system in buildings and the new TN-S-five-core house-connection cable for connections between the mains distribution point and buildings is introduced. The long-term target of providing TN-S-systems in power distribution even as far as the local transformer is also discussed. The advantages of the system are discussed and various configurations for different types of supply are described.

2005-07-01

163

Underground high-power transmission: first results of testing a 110 kV lowpressure oil-filled cable with a water cooled conductor in Berlin (West), Germany  

Energy Technology Data Exchange (ETDEWEB)

The Berliner Kraft- u. Licht (BEWAG)AG have been conducting investigations during the last several years on a 110 kV low-pressure oil-filled high-power cable with a water cooled conductor and a load capacity of 950 MVA at 110 kV. After successful transport of the cable drums (weight: 16 metric tons; diameter: 4.9 m) from the manufacturing in Cologne, West Germany, to Berlin (West), and after laying of the cable over a 300 m stretch, the commissioning tests in accordance with IEC and VDE* standards have been concluded, and several loadings with a current of 5000 A have been performed. Now, after completion of various improvements in the test system, preparations are underway for initiation of long-term testing over a period of approx. 18 months.

1982-07-01

164

Underground cable: Best for cogeneration links  

Energy Technology Data Exchange (ETDEWEB)

This article addresses the connection of cogeneration plants to the utility system. The article provides examples for use in illustrating the problems that must be overcome and the solution chosen. These illustrations include high voltage utility connection, multiple connections to the utility at one location, and dealing with losses and obstructions.

1989-05-01

165

How to charge electric-powered automobiles; Volle Ladung, aber wie?  

Energy Technology Data Exchange (ETDEWEB)

Electric cars can be recharged via charging stations, battery exchange, or induction cable lanes in asphalted roads. The users' wishes remain unexplored, so a number of technologies are competing in this sector.

2011-01-15

166

Estimating production rates and operating costs of timber harvesting equipment in the northern Rockies. General technical report  

Energy Technology Data Exchange (ETDEWEB)

The report summarizes studies of ground, cable, and aerial logging systems in the Northern Rockies over a 15-year period. It provides nomographs and tables for calculating productivity and a system for comparing energy requirements.

1982-09-01

167

Criminal Prohibitions on the Publication of Classified Defense Information. Updated December 6, 2010.  

Science.gov (United States)

The recent online publication of classified defense documents and diplomatic cables by the organization WikiLeaks and subsequent reporting by the New York Times and other news media have focused attention on whether such publication violates U.S. criminal...

2010-01-01

168

A stand for testing supports  

Energy Technology Data Exchange (ETDEWEB)

The stand is designed to test supports of development workings. To expand the test range for various types of supports, the cross pieces have fixing devices in the form of winches interacting by cables through blocks fastened to the stand body with the support hinges.

1980-07-30

169

Submarine 525 kV power transmission line for Vancouver island  

Energy Technology Data Exchange (ETDEWEB)

The studies undertaken by the B.C. Hydro company at the Canada showed that the existing system of hydroelectric power plants and transport cables will not be able to satisfy the increasing energy demand on the Vancouver island after 1985, and that the best solution will be the installation of a 525 kV transfer system from the continent. THe STK participated to the development and the immersion of this new system, the first in the world comprising submarine 525 kV transport parts. This paper presents the planning, the development, the submerging and the installation of two sections of submarine cable.

1985-01-01

170

Lessons from Auckland  

Energy Technology Data Exchange (ETDEWEB)

The major distributor and retailer of electrical power to Auckland, New Zealand, is Mercury Energy Limited. Following the sequential failure of the four 110kV underground cables, two gas-filled and two oil-filled, which supply the central business district, power was interrupted for 29 days from the 20th February 1998. A government inquiry was instituted, to examine what happened, why, and what lessons could be drawn for the future. Inadequacies in Mercury Energy`s cable maintenance and operating procedures were identified. The findings of the inquiry and its recommendations are reported. (UK)

1998-08-01

171

Fiber optic quality assurance at the Nevada Test Site  

Energy Technology Data Exchange (ETDEWEB)

A large number of fiber optic cables were used in support of a neutron imaging experiment at the Nevada Test Site. This paper describes the quality control testing of fiber components used on this experiment. The principal reason for quality control testing was to ensure reliable, high transmission fibers; a secondary reason was to gain data on a large sample of fiber cables in the field. Also described is the instrumentation developed for carrying out these field measurements. The design of the quality control instrumentation was a compromise between accuracy and simplicity of use.

1981-01-01

172

Electric power cable  

Energy Technology Data Exchange (ETDEWEB)

An oil-immersion electrically insulated cable of high performance is constructed by wrapping a conductor with an insulating layer formed by winding on the conductor polypropylene film, and impregnating the insulating layer with an insulating oil preferably dodecyl benzene. The polypropylene film has a density in the range of 0.905 to 0.915 g/cm/sup 3/, birefringence in the range of 0.020 to 0.035, ratio of strengths in two axial directions (tensile strength in the longitudinal direction/tensile strength in the lateral direction) in the range of 5 to 15, and thickness in the range of 70 to 300 microns.

1987-08-14

173

Computer modeling of electrical performance of detonators  

Energy Technology Data Exchange (ETDEWEB)

An empirical model of detonator electrical performance which describes the resistance of the exploding bridgewire (EBW) or exploding foil initiator (EFI or slapper) as a function of energy, deposition will be described. This model features many parameters that can be adjusted to obtain a close fit to experimental data. This has been demonstrated using recent experimental data taken with the cable discharge system located at Sandia National Laboratories. This paper will be a continuation of the paper entitled ``Cable Discharge System for Fundamental Detonator Studies`` presented at the 2nd NASA/DOD/DOE Pyrotechnic Workshop.

1995-05-01

174

A Insulating Design of SF{sub 6} GAS Sealing end of Condenser Cone Type Used for 345 kV OF Cable  

Energy Technology Data Exchange (ETDEWEB)

In this paper, we describes the research in condenser cone of SF{sub 6} gas sealing end for 345 kV oil-filled cable. The designed of condenser cone based on the results electric field analysis by electrostatics theory and FEM. As a results, we have been designed the condenser cone and the inner insulation part of SF{sub 6} sealing end, the width and length, the number of condenser, the length of stress relief slope, the total length of condenser cone. (author). 4 refs., 3 figs., 3 tabs.

1994-07-01

175

500-kV cable lines  

Energy Technology Data Exchange (ETDEWEB)

A detailed description is given of the design, fabrication, and installation of oil-filled 500-kV cable lines used for the first time in the USSR for transmitting electric power from step-up transformers installed several meters from the hydroelectric generators to an outdoor distribution system or a junction point at which they are connected to overhead power transmission lines. These lines are 950 to 1050 m long and they are placed at levels differing by 45 m along the route. These lines can transmit power as great as 630 MV.A.

1980-01-01

176

The electrical measurement of AC losses in a three-phase tri-axial superconducting cable  

International Nuclear Information System (INIS)

In a three-phase tri-axial cable, the magnetic interaction between the phases makes the loss measurement by an electromagnetic method very complex. We developed the theoretical background showing that three-phase AC loss measurements by the electromagnetic method are, in principle, possible. We then implemented this theory in practical measurements on a 3 m long, tri-axial cable fabricated from RABiTS (rolling-assisted biaxially textured substrate) coated conductor. Initially, the proposed measurement technique was implemented in the simpler cases when the three cable phases are 180"0 out of phase, i.e. (0"0, 180"0, 360"0) or (0"0, 360"0, 180"0) rather than (0"0, 120"0, 240"0) as in a traditional three-phase system. For these cases, the currents in the phases are either in phase (360"0 phase difference) or anti-phase (180"0 phase difference). These are essentially single-phase measurements with only one transport current ...

2010-09-01

178

Dynamics of photosynthetic photon flux density (PPFD) and estimates in coastal northern California  

British Library Electronic Table of Contents (United Kingdom)

Plants require solar radiation for photosynthesis and their growth is directly related to the amount received, assuming that other environmental parameters are not limiting. Therefore, precise estimation of photosynthetically active radiation (PAR) is necessary to enhance overall accuracies of plant growth models. This study aimed to explore the PAR radiant flux in the San Francisco Bay Area of northern California. During the growing season (March through August) for 2?years 2007?2008, the on-site magnitudes of photosynthetic photon flux densities (PPFD) were investigated and then processed at both the hourly and daily time scales. Combined with global solar radiation (R S) and simulated extraterrestrial solar radiation, five PAR-related values were developed, i.e., flux density-based PAR ...

2011-01-01

179

A wave effect enabling universal frequency scaling, monostatic passive radar, incoherent aperture synthesis, and general immunity to jamming and interference  

CERN Document Server

A fundamental Doppler-like but asymmetric wave effect that shifts received signals in frequency in proportion to their respective source distances, was recently described as means for a whole new generation of communication technology using angle and distance, potentially replacing TDM, FDM or CDMA, for multiplexing. It is equivalent to wave packet compression by scaling of time at the receiver, converting path-dependent phase into distance-dependent shifts, and can multiply the capacity of physical channels. The effect was hitherto unsuspected in physics, appears to be responsible for both the cosmological acceleration and the Pioneer 10/11 anomaly, and is exhibited in audio data. This paper discusses how it may be exploited for instant, passive ranging of signal sources, for verification, rescue and navigation; incoherent aperture synthesis for smaller, yet more accurate radars; universal immunity to jamming or interference; and precision frequency scaling of ...

2008-01-01

180

White oils for high voltage cables  

Energy Technology Data Exchange (ETDEWEB)

''S-220'' white oil is used currently to impregnate and fill high voltage cables for 110-500 kilovolts; it has high electrical characteristics and meets production and use standards. High pressure and cooling problems, however, require filling cables with lower viscosity oils, while insulation needs still demand high viscosity. The authors developed a new white oil similar to S-220 using a neutral oil made in producing sulfonate additives. The process involved vacuum distillation, low-temperature paraffination, sulfation with oleum, neutralizing with ammonium hydroxide and simultaneous extraction of sulfo-salts and contact purification. The lowest content of aromatic hydrocarbons was sought. Dielectric qualities varied with viscosity. Satisfactory thermooxidational capability was found at 50/sup 0/C with an oil of no less than 50 mm/sup 2//sec viscosity. The final white oil had no more than 2% aromatic ...

1982-10-01

181

The result of Alanine/ESR dosimetry at Wolsung unit 1  

International Nuclear Information System (INIS)

It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate dose, two environmental correction factors, ...

2008-10-01

182

Short circuit strength of surface mounted 110 kV cables; Kurzschlussverhalten von 110-kV-Kabeln in offener Legung  

Energy Technology Data Exchange (ETDEWEB)

The danger potential for 110 kV cables, which are installed on racks and in tunnels, caused by catching fire because of arcing short circuits and mechanical overstressing by peak shortcircuit current, has been experimental analysed under Bewag network conditions. As a result, recommendations for an improved installation of 110 kV cables are given. (orig.) [Deutsch] Fuer offen gelegte 110-kV-Kabel in Raeumen, auf Fussboeden und in Schaechten wurde das von Kurzschluessen auf den Kabeln ausgehende Gefaehrdungspotential fuer die Entstehung von Kabelbraenden durch Fehlerlichtboegen und fuer eine mechanische Ueberbeanspruchung von Kabeln durch Stosskurzschlussstroeme unter Beruecksichtigung der Netzverhaeltnisse der Bewag experimentell untersucht. Im Ergebnis geben die Verfasser Empfehlungen fuer die sichere Anordnung offen gelegter 110-kV-Kabel. (orig.)

1998-03-23

183

Ramp-rate sensitivity of SSC dipole magnet prototypes  

Energy Technology Data Exchange (ETDEWEB)

One of the major achievements of the magnet R&D program for the Superconducting Super Collider (SSC) is the fabrication and test of a series of 20 5-cm aperture, 15-m long dipole magnet prototypes. The ramp rate sensitivity of these magnets appears to fall in at least two categories that can be correlated to the manufacturer and production batch of the strands used for the inner-coil cables. The first category, referred to as type-A, is characterized by a strong quench current degradation at high ramp rates, usually accompanied by large distortions of the multipole fields and large energy losses. The second category, referred to as type-B, is characterized by a sudden drop of quench current at low ramp rates, followed by a much milder degradation at larger rates. The multipole fields of the type-B magnets show little ramp-rate sensitivity, and the energy losses are smaller than for the type-A magnets. The behavior of the Type-A magnets can be explained in terms ...

1994-07-01

184

R and D for a single-layer Nb{sub 3}Sn common coil dipole using the react-and-wind fabrication technique  

Energy Technology Data Exchange (ETDEWEB)

A dipole magnet based on the common coil design, using prereacted Nb{sub 3}Sn superconductor, is under development at Fermilab, for a future Very Large Hadron Collider. This magnet has some innovative design and technological features such as single layer coils, a 22 mm wide 60-strand Rutherford type cable and stainless steel collars reinforced by horizontal bridges inserted between coil blocks. Both left and right coils are wound simultaneously into the collar structure and then impregnated with epoxy. In order to optimize the design and fabrication techniques an R&D program is underway. The production of cables with the required characteristics was shown possible. Collar laminations were produced, assembled and tested in order to check the effectiveness of the bridges and the validity of the mechanical design. A mechanical model consisting of a 165 mm long section of the magnet straight section was assembled and tested. This paper ...

2002-01-14

185

Development of a leak location system for use on underground electric power transmission cable. Final report  

Energy Technology Data Exchange (ETDEWEB)

This report describes a study to evaluate methods for locating leaks of dielectric fluid from buried high-voltage cable systems. Two primary types of leak location systems were investigated: (1) systems that will rapidly isolate the leak within a manhole section, typically 1000-m long on a feeder that might be 30-km long; and (2) systems that will then pinpoint the location of the leak. Rapid leak isolation was accomplished by developing an enhanced conductivity oil probe which allows the injection of a small quantity of conductive oil and which indicates the path of the oil as it drifts downstream in the direction of the leak. Two methods for pinpointing the leak were proven. The more successful method was the use of trained leak location dogs which were found to have far better sensitivity than instruments and which could detect cable oil alone without the need for additives. A tracer gas injection and detection scheme was developed for use ...

1982-10-01

186

Heat Transfer Augmentation in a Compact Heat Exchange Pedestal Array.  

Science.gov (United States)

A compact heat exchanger pedestal array for augmenting heat transfer in a machine is disclosed. The compact heat exchanger pedestal array includes a wall having first and second surfaces. The first surface faces a heated flow path and the second surface p...

2004-01-01

187

Development of a non-premix radiant burner. Final report  

Energy Technology Data Exchange (ETDEWEB)

The objective of the first project period is to: make a study into materials suitable for the non-premix radiant burners (NPRB); choose the materials for the construction; make proposals for the design of the NPRB; test the different proposals with a CFD-model. In pursuit of finding a suitable material it is necessary first to estimate the maximum temperature that will occur in the burner. It has been estimated that the maximum adiabatic flame temperature will be about 2400-2500 K. The maximum temperature in the burner will of course never reach this level. A more realistic temperature was estimated to 2100-2300 K. The final choice was made after having contacted some of the leading producers. It was possible to find one producer that could produce burners of one of the suggested materials, zirconia. Several construction ideas for the NPRB have been discussed and some of them tested with a CFD-model. The proposed burner concept has been modified in order to obtain ...

1998-12-31

188

Loading of wellbores with explosives  

Energy Technology Data Exchange (ETDEWEB)

Bags of explosive are loaded rapidly into deep wellbores by suspending a rigid positioning tube partway into the wellbore, and loading the bags into the tube, the bags being prevented from dropping through the open bottom end of the tube by a cord attached to the lowermost bag and secured at the upper end of the tube when the tube-suspending cable is in tension by a cordsecuring/releasing means, E.G., a pivotable bar having a hook on one end. When the bag-laden tube is lowered to the bottom of the wellbore, or to a column of bags previously placed therein, the tension on the cable is relaxed and the cord is released, allowing the positioning tube thereafter to be raised to the surface for re-use, leaving the cord and bags in the wellbore. Freedom of the bag-supporting cord to move with respect to the positioning tube when the latter is raised to the surface is assured by threading the cord through plastic tubing mounted to the wall of the ...

1983-04-26

189

Light weight underground pipe or cable installing device  

Energy Technology Data Exchange (ETDEWEB)

This invention pertains to a light weight underground pipe or cable installing device adapted for use in a narrow and deep operating trench. More particularly this underground pipe installing device employs a pair of laterally movable gates positioned adjacent the bottom of the operating trench where the earth is more solid to securely clamp the device in the operating trench to enable it to withstand the forces exerted as the actuating rod is forced through the earth from the so-called operating trench to the target trench. To accommodate the laterally movable gates positioned adjacent the bottom of the narrow pipe installing device, a pair of top operated double-acting rod clamping jaws, operated by a hydraulic cylinder positioned above the actuating rod are employed.

1985-01-08

190

Electrical Transmission Line Diametrical Retention Mechanism  

Science.gov (United States)

The invention is a mechanism for retaining an electrical transmission line. In one embodiment of the invention it is a system for retaining an electrical transmission line within downhole components. The invention allows a transmission line to be attached to the internal diameter of drilling components that have a substantially uniform drilling diameter. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string, drill collars, heavy weight drill pipe, and jars. The system also includes a coaxial cable running between the first and second end of a drill pipe, the coaxial cable having a conductive tube and a conductive core within it. The invention allows the electrical transmission line to withstand the tension and compression of drill pipe during routine drilling cycles.

2006-01-03

191

Design of Reactor Head Structure Assembly Using Axiomatic Design  

Energy Technology Data Exchange (ETDEWEB)

The Reactor Head Structure Assembly(RHSA) is the structure located on the reactor assembly. The purpose of the assembly is providing interface location for cables, preventing pipe whips, prohibiting instruments from becoming missiles, and restraining CEDMs' horizontal motion. On the RHSA, Reactor Disconnect Panels(RDP) are installed. The installation location of RDP is to be decided to minimize the geometric interface with other components. Since the neighborhood of RHSA is crowded due to many connectors and cables, it is necessary to find the good design of RHSA to make an intricate situation attenuated and the required function maintained. The geometric shape and overall configuration of RHSA are determined by axiomatic design approach. The FRs of RHSA are specified and the corresponding DPs are found to satisfy FRs in sequence. The finite element analysis is carried out based on the result of the axiomatic design to evaluate the ...

2007-07-01

192

Large Eddy Simulation for Heat Transfer Prediction in a Gas ...  

Science.gov (United States)

... turbine blade heat-transfer and study the heat-transfer augmentation in idealized geometry and its ... responsible for heat transfer augmentation. ...

2007-03-30

194

White oils for high voltage cables  

Energy Technology Data Exchange (ETDEWEB)

S-120 white oils are used to impregnate insulation and fill high voltage wires. Cooling oil flows of specified viscosities can increase the load capacity of wires. White oils are studied for viscosities and dielectric properties. To meet requirements, S-220 type oils of different medium or low viscosities are tested. Capacity can be increased by viscosity adjustment. Tests were also made to select optimum stabilizing additives to keep low-viscosity.

1983-05-01

195

Tritium contamination and decontamination study on materials for ITER remote handling equipment  

Energy Technology Data Exchange (ETDEWEB)

Several materials, lenses, dry bearings and cables were exposed to a tritiated moisture environment to study the behavior of tritium contamination on candidate materials for ITER remote handling equipment. To optimize the tritium removal procedure, decontamination experiments using a gas purge with three different moisture concentrations were also performed. The surface tritium concentrations of CeO{sub 2} containing alkaline barium glass (NB), CeO{sub 2} containing lead glass (LX) and synthetic quartz (Quartz) after the exposure experiments were 7.80, 10.94 and 0.67 Bq/cm{sup 2}, respectively. It was found that the tritium concentration was influenced by the compositions of the materials. The concentrations of tritium on type 831 (solid lubrication material: graphite) and type 237 (solid lubrication material: tungsten disulfate) dry bearings after the exposure experiments were 89.80 and 31.78 Bq/cm{sup 2}, respectively. The tritium concentration in an electric ...

2001-09-01

196

Tritium contamination and decontamination study on materials for ITER remote handling equipment  

International Nuclear Information System (INIS)

Several materials, lenses, dry bearings and cables were exposed to a tritiated moisture environment to study the behavior of tritium contamination on candidate materials for ITER remote handling equipment. To optimize the tritium removal procedure, decontamination experiments using a gas purge with three different moisture concentrations were also performed. The surface tritium concentrations of CeO_2 containing alkaline barium glass (NB), CeO_2 containing lead glass (LX) and synthetic quartz (Quartz) after the exposure experiments were 7.80, 10.94 and 0.67 Bq/cm"2, respectively. It was found that the tritium concentration was influenced by the compositions of the materials. The concentrations of tritium on type 831 (solid lubrication material: graphite) and type 237 (solid lubrication material: tungsten disulfate) dry bearings after the exposure experiments were 89.80 and 31.78 Bq/cm"2, respectively. The tritium concentration in an electric ...

2001-09-01

197

Session 1: Geothermal Pumping Systems and Two-Phase Flow Studies  

Energy Technology Data Exchange (ETDEWEB)

Improvements in electric submersible pumping systems have resulted in a demonstrated downhole running life of one year for low horsepower units operating in 180 C brine. The implementation of a prototype pressurized lubrication system to prevent brine intrusion and loss of lubricating oil from the motor and protector sections has been successfully tested. Second generation pressurized lubrication systems have been designed and fabricated and will be utilized in downhole production pumping tests during FY84. Pumping system lifetime is currently limited by available power cable designs that are degraded by high-temperature brine. A prototype metal-sheathed power cable has been designed and fabricated and is currently undergoing destructive and nondestructive laboratory testing. This cable design has the potential for eliminating brine intrusion into the power delivery system through the use of a hermatically sealed ...

1983-12-01

198

Revolutionary news on superconductivity  

Energy Technology Data Exchange (ETDEWEB)

A brief article gives an update on the commercial exploitation of superconductivity by the American Superconductor Corporation. Potential applications include transmission and distribution, motors, magnetic storage systems, current limiters and transport. The company have produced a kilometre long, ''wrappable'' cable capable of carrying thousands of amps when operating at a temperature of below -140[sup o]C. (UK)

1994-09-01

199

Operation of an 18-fold segmented n-type HPGe detector in liquid nitrogen  

International Nuclear Information System (INIS)

For the first time a segmented n-type HPGe detector was operated directly submerged in liquid nitrogen over a long period. As this kind of detector is envisioned to be used in GERDA phase II, it was operated with a low mass signal cable with snap-contacts and mounted in a low-mass copper holder. The detector performance was stable over 146 days, indicating that neither detector nor contacts deteriorated.

2009-11-01

200

Oceans 82 conference record: Industry, government, education. partners in progress  

Energy Technology Data Exchange (ETDEWEB)

Separate abstracts were prepared for 20 papers in this conference report and includes all papers in the ''engineering'' section (program E). Ocean thermal energy conversion (OTEC), moorings, cables, corrosion protection, corrosion testing, coatings, offshore platforms, pipelines, OTEC models and pilot plants, and energy transfer are topics discussed.

1982-01-01

201

Laser applications. Final report  

Energy Technology Data Exchange (ETDEWEB)

Processes were developed that use lasers as manufacturing tools. These processes were stripping of insulation from cables and wires, machining of quartz, microdrilling and welding of reflective metals, and precision alignment of curved surfaces before machining. A technological basis also was formed which resulted in a process for automatic surface inspection of parts and aided development of machining processes for Kevlar parts.

1980-07-01

202

Interconnection France-England; Interconnexion France-Angleterre  

Energy Technology Data Exchange (ETDEWEB)

These documents defines the interconnection France-England rules for the 2000 MW DC submarine cable directly linking the transmission networks of England and Wales and France. Rights to use Interconnector capacity from 1 April 2001 are to be offered through competitive tenders and auctions, full details of which are set out in the Rules. The contract and a guide to the application form are provided. (A.L.B.)

2001-07-01

203

High temperature liquid level sensor  

International Nuclear Information System (INIS)

A length of metal sheathed metal oxide cable is perforated to permit liquid access to the insulation about a pair of conductors spaced close to one another. Changes in resistance across the conductors will be a function of liquid level, since the wetted insulation will have greater electrical conductivity than that of the dry insulation above the liquid elevation.

1983-03-01

204

Electrical equipment of the Marchtrenk power station on the river Traun  

Energy Technology Data Exchange (ETDEWEB)

By way of introduction, the author describes the electrical equipment of the power station on the River Traun and then lists the main features of the electrical systems such as generators, transformers, the power transmission systems as, e.g., the generator leads, the 8 kV switch plant, the 110 kV oil-filled cable as well as the station-service, control, protection and monitoring systems. The control of the headwater level and of the mechanical systems of the barrage is described in detail.

1982-03-01

206

Development of 345-kV capacitive-graded joint. Final report  

Energy Technology Data Exchange (ETDEWEB)

The design of a 345-kV prefabricated capacitive-graded joint for oil-filled cables and the manufacture and testing of prototype joints are described. Tests on prototype No. 4 demonstrated the adequacy of the printed circuit design. It was not possible to consistently obtain high-quality capacitive sheets and substantial effort is required to remedy this problem. Advantages of these prefabricated joints are summarized, and specific recommendations are made for further development of the concept.

1980-09-01

207

Corona effect in high voltage transmission lines; O efeito corona em linhas eletricas aereas de alta-tensao  

Energy Technology Data Exchange (ETDEWEB)

Corona from bare conductors of electrical overhead power lines is studied in this article. Its origin, as well as, its bad influences over communication systems are both studied, yet. Line`s models are defined, in order to be able the examination of Corona on line`s cables. Formulas for the surface electrical gradient calculations are shown. (author) 2 refs.

1993-12-01

208

An analysis of selected atmospheric icing events on test cables  

Energy Technology Data Exchange (ETDEWEB)

In cold countries, the design of transmission lines and communication networks requires the knowledge of ice loads on conductors. Atmospheric icing is a stochastic phenomenon and therefore probabilistic design is used more and more for structure icing analysis. For strength and reliability assessments, a data base on atmospheric icing is needed to characterize the distributions of ice load and corresponding meteorological parameters. A test site where icing is frequent is used to obtain field data on atmospheric icing. This test site is located on the Mt. Valin, near Chicoutimi, Quebec, Canada. The experimental installation is mainly composed of various instrumented but non-energized test cables, meteorological instruments, a data acquisition system, and a video recorder. Several types of icing events can produce large ice accretions dangerous for land-based structures. They are rime due to in-cloud icing, glaze caused by freezing rain, wet snow, and mixtures of ...

1996-12-01

209

A HELICAL MAGNET DESIGN FOR RHIC.  

Energy Technology Data Exchange (ETDEWEB)

Helical dipole magnets are required in a project for the Relativistic Heavy Ion Collider (RHIC) to control and preserve the beam polarization in order to allow the collision of polarized proton beams. Specifications are for low current superconducting magnets with a 100 mm coil aperture and a 4 Tesla field in which the field rotates 360 degrees over a distance of 2.4 meters. A magnet meeting the requirements has been developed that uses a small diameter cable wound into helical grooves machined into a thick-walled aluminum cylinder.

1997-05-12

211

Scour protection for wind turbine foundations on highly erodible sea bottom  

Energy Technology Data Exchange (ETDEWEB)

Scour around offshore structures is well known. It is caused by the strong eddy formation at the base of the structures protruding from the sea bottom. The strong vortices result in an amplified effective shear stress working on the sea bottom surface adjacent to the structure. When the surrounding sea bottom is lowered the scour protection will end up being a cap on a small hill and when the slopes are getting too steep the scour protection will roll or slide down the sides. It will loose its cohesion and therefore its integrity. This will take place irrespective of the type of scour protection material and the type of scour protection. This report describes scour protections, which can deal with this particular problem. Such a scour protection must be able to sustain the following loads: Be able to follow the lowering of the seabed on its way down; Be resistant to edge scour (scour around the perimeter of the scour protection). The installation of scour protection is not ...

2002-12-01

212

Literature and patent searches on the subject of controllable heat transfer. Final report. Literatur- und Patentrecherche zum Thema Schaltbarer Waermedurchgang. Abschlussbericht  

Energy Technology Data Exchange (ETDEWEB)

The possibility of switching the heat transfer consists of varying heat transfer surfaces and making the heat transfer temporarily more intensive. Heat tubes prove to be particularly suitable, which must be exposed to a heat carrier fluid or removed from its effect for switching the heat transfer. This report gives a survey of the possibilities of switching heat flows and for making the heat transfer more intensive. Further, the report contains a survey of patents limited to heat transfer in the fields of cooling internal combustion engines and exhaust systems. (orig.) With 17 figs., 183 refs.

1989-01-01

213

Using of beam spoilers in linear accelerators with photons of 10 MV  

International Nuclear Information System (INIS)

This work come along of the necessity to utilize an unique High-Energy Electron Linear Accelerator (10 MV) for radiant treatments which require higher doses in the surface levels of tissue. It is analyzed the interposition of acrylic degraders (spoilers) in the beam, especially for opposed and parallel fields in the cases of head and neck. It was analyzed the possible combinations of the following parameters: 1) Field sizes defined at isocenter (100 cm) 6 x 6 cm"2, 8 x 8 cm"2 and 10 x 10 cm"2 ; 2) Surface-spoiler distance (DSS) of 4, 7 and 10 cm; 3) Spoilers with different thickness 1.1 and 1.5 cm. It was observed a displacement of the maximum dose toward the surface, and an increase in the percentile doses in the build-up zone when the spoiler is nearing and/or increasing its thickness. It is verified that the use of spoilers, support the symmetry and plane of the beam inside of the clinically acceptable margins. When the results obtained are analyzed then it is ...

1998-11-22

214

Nonlinear pulse evolution in seeded free-electron laser amplifiers and in free-electron laser cascades  

International Nuclear Information System (INIS)

The advances in laser technology have made available very short and intense laser pulses which can be used to seed a high-gain single-pass free-electron laser (FEL) amplifier. With these seed pulses, a regime of the FEL interaction where the radiation evolution is simultaneously dominated by nonlinear effects (saturation) and time-dependent effects (slippage) can be explored. This regime is characterized by the propagation of a solitary wavelike pulse where the power of the optical wave grows quadratically with time, its pulse length decreases and the spectral bandwidth increases. We analyze the interplay between the field and particle dynamics of this propagation regime which was studied before and termed super-radiance. Furthermore we analyze the properties of the strong higher-order harmonic emission from this wave and its behavior when propagating in a cascade FEL. The super-radiant pulse is indeed capable of passing through the stages of a cascade FEL and to ...

2005-08-15

215

Experimental study of the premixed combustion within the nonhomogeneous porous ceramic media  

Energy Technology Data Exchange (ETDEWEB)

An experimental investigation of premixed methane-air combustion within the one-dimensional porous ceramic burners for various burner configurations is presented. The burner is nonhomogeneous because of different pore size ceramic block used in different section of the burner. Therefore, the thermophysical and transport properties are nonuniform along the burner core length. The burners are constructed of partially stabilized zirconia. The CO and NO{sub x} emissions, flame speed, and flame stability are examined and compared at lean equivalence ratios for five different burner configurations. The sandwich-structured burner has very favorable flame stabilizing characteristic due to the radiation reflecting region. While the combustion proceeds at faster rate than other burner configurations, the radiation reflecting region and the exit surface have low temperature. Thus the NO{sub x} emission can be kept at the same low level as the other burner configurations exhibit., It is found that ...

1996-12-01

216

Cylindrical heat receiver for thermal solar-energy converters  

Energy Technology Data Exchange (ETDEWEB)

Theoretical and experimental results of investigating a cylindrical heat receiver with secondary reflectors are presented. One important element of solar thermal power plants (STPP) is the heat receiver. Several forms of heat receiver exist; the main form is the heat receiver of cavity form (including cylindrical, rectangular, and cubic heat receivers with a noncircular aperture). The linear dimension of such heat receivers is equal to, or larger than, the theoretical diameter of the concentrator focal spot.

1984-01-01

217

Advances in enhanced heat transfer: 1987  

Energy Technology Data Exchange (ETDEWEB)

This book contains nine selections. Some of the titles are: High Heat-Flux, Forced-Convection Heat Transfer for Tubes with Twisted-Tape Inserts; Heat Transfer Augmentation by Interrupted Surfaces - Experimental Consideration; Turbulent Flow Heat Transfer from Externally Roughened Tubes in Axial Flow in Concentric Pipe Heat Exchangers; and Heat Transfer Enhancement of Turbulent Flow in Pipes with an Internal Circular Rib.

1987-01-01

218

Advances in enhanced heat transfer: 1987  

International Nuclear Information System (INIS)

This book contains nine selections. Some of the titles are: High Heat-Flux, Forced-Convection Heat Transfer for Tubes with Twisted-Tape Inserts; Heat Transfer Augmentation by Interrupted Surfaces - Experimental Consideration; Turbulent Flow Heat Transfer from Externally Roughened Tubes in Axial Flow in Concentric Pipe Heat Exchangers; and Heat Transfer Enhancement of Turbulent Flow in Pipes with an Internal Circular Rib.

1987-08-09

219

Emergency core cooling device for a reactor  

International Nuclear Information System (INIS)

Purpose : To obtain an emergency core cooling device in a FBR type reactor by utilizing heat pipes which are not actuated at usual operation condition but actuated reliably upon emergency. Constitution : A system for injecting heat medium into heat pipes is provided. By injecting the heat medium into the heat pipes upon emergency to actuate the heat pipes, the reactor core is cooled. During normal reactor operation, the inside of the heat pipes is evacuated from a vacuum pump and no heat medium is filled therein, whereby unnecessary heat loss during the normal operation can be prevented. (Ikeda, J.).

1982-01-24

220

Optimal thermodynamic heat transfer  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a set of heuristics useful for optimal design of heat-exchange networks and integrated heat and power systems. These heuristics consolidate other approaches reported in the literature in a formalism useful for design purposes.

1989-06-01

221

Numerical simulation of fluid flow and heat transfer in a concentric tube heat exchanger  

International Nuclear Information System (INIS)

In this paper, numerical simulation of a concentric tube heat exchanger is presented to determine the convective heat transfer coefficient and friction factor in a smooth tube. Increasing the convective heat transfer coefficient can increase heat transfer rate in a concentric tube heat exchanger from a given tubular surface area. This can be achieved by using heat transfer augmentation devices. This work constitutes the initial phase of the numerical simulation of heat transfer from tubes employing augmentation devices, such as twisted tapes, wire-coil inserts, for heat transfer enhancement. A computational fluid dynamics (CFD) simulation tool was developed with CFX software and the results obtained from the simulations are validated with the empirical correlations for a smooth tube heat exchanger. ...

2003-05-28

222

Conjugate Heat Transfer Predictions of a Combustor ...  

Science.gov (United States)

... To maximise heat transfer rates, many heatshield designs make use of heat transfer augmentation devices such as large numbers of pin-fin ...

2003-03-01

223

Augmentation of heat and mass transfer  

Energy Technology Data Exchange (ETDEWEB)

This is the first text and reference book to be devoted completely to the very important and timely subject of heat transfer augmentation. This book is of equal appeal to both researchers and designers of heat transfer equipment.

1986-01-01

224

Transient overvoltages and overcurrents during line fault tests on the Hokkaido-Honshu HVDC line  

Energy Technology Data Exchange (ETDEWEB)

A series of line fault tests have been conducted at completion of Stage I of the Hokkaido-Honshu HVDC Link of Electric Power Development Co., Ltd., prior to its commercial operation, in order to study transient overvoltages and overcurrents and to confirm safety operation of system protecting devices in case of DC transmission line faults. The Hokkaido-Honshu HVDC Link is a metallic return HVDC overhead line and cable transmission system, currently being a monopolar system. For this, measurements were conducted this time on reverse polarity overvoltages occurring on main line cable, return line overvoltages, fault arc dynamic characteristics, and DC bypass current through the AC system. The results obtained were then compared with the analysis results by the HVDC surge similator or digital simulation conducted for system design prior to the field tests. As a result, a close accordance was found between them, in confirmation of the effectiveness ...

1982-08-01

225

The Schenberg spherical antenna: status report  

International Nuclear Information System (INIS)

Full text. Here we present a status report of the Schenberg antenna, which started commissioning runs in September 2006 under the full support of FAPESP. In its first commissioning runs we tested three preliminary parametric transducer systems, which did not achieve a high enough performance for placing the antenna sensitivity in the range of the calibrator capacitor. Instead of improving the calibrator, making it capable of introducing a larger input force, we decided to go to a radical upgrading operation: replacing the three transducers for a complete set of six transducers, with better sensitivity and arranged according to the truncated icosahedron configuration, plus two extra ones; starting to install the dilution refrigerator; installing wires, cables, and amplifiers for the complete set of transducer circuits; and a new suspension and vibration isolation system for the cabling and microstrip antennas. We also have been developing a new ...

2009-09-14

226

Structural design and fabrication of the Sandia 34-meter Vertical Axis Wind Turbine  

Science.gov (United States)

The Wind Energy Research Division of Sandia National Laboratories has been funded by the Wind/Ocean Technology Division of the Department of Energy (DOE) to design and build a 34-meter diameter Vertical Axis Wind Turbine (VAWT). The turbine design incorporates the results of recent VAWT research in aerodynamics and structural dynamics. Initial system concept studies identified several blade options that met the required power rating of 500 kW. The final blade and rotor configurations were chosen based on finite element calculations that determined the turbine modes of response, their frequency of vibration, and stress levels. For parked survival turbine components were designed to with stand the loading of a 150 mph (67.0 m/s) wind coupled with maximum cable tensions. Specific areas of design discussed include the rotor, cables, bearings, brakes, and foundations. Construction of the turbine is in progress at this time and anticipated completion ...

1987-01-01

227

Proceedings: Water treeing and aging  

Energy Technology Data Exchange (ETDEWEB)

This report presents the record of the workshop Water Treeing and Aging.'' The workshop was held in Phoenix, Arizona on December 9--11, 1990 and was sponsored by the Distribution Program of the Electrical Systems Division of the Electric Power Research Institute (EPRI). Attendance at the workshop was by invitation only. Twenty two attendees from seven countries, from universities, research organizations, electric utilities and polymeric materials suppliers took part in this workshop. The workshop was designed to assess progress in the understanding of water treeing phenomena and polymeric cable insulation aging since the last meeting of a similar forum of experts, which was organized by the Office of Exploratory Research of EPRI in December 1985. The objective of the present workshop was to assess progress and to provide direction for further studies in this field. The discussions covered a wide range of subjects including water tree structure, ...

1991-10-01

228

Non-Destructive Testing of Bus-Bar Joints Powering LHC Superconducting Magnets, by Using Gamma Sources  

CERN Document Server

The main LHC superconducting magnets (dipoles and quadrupoles) use Rutherford type cables, stabilized electrically and thermally with copper profiles. The portions of cables are connected to each other by a soft soldering technique (Sn96Ag4) with an overlapping length corresponding to one pitch of the superconducting strands. The splice constitutes a "composite" structure with the interchanging layers of Sn96Ag4 and NbTi superconductor, located inside a Cu cage. In order to ensure a high level of reliability (failure probability not exceeding 10-8) for some 10000 connections in the LHC, a non-destructive technique to check the quantity of solder in the joint is foreseen. The technique is based on a gamma ray source (241Am) and the detection is position-sensitive in the transmission mode. Scintillating detectors of gamma rays are used and their accumulated length corresponds to the length of the radioactive source (120 mm). The method can be ...

2004-01-01

229

Nb{sub 3}Sn LLNL cable test strand  

Energy Technology Data Exchange (ETDEWEB)

Axial strain characterization was completed for a Nb{sub 3}Sn conductor from Lawrence Livermore National Lab used in a transverse stress test of a cable-in-conduit conductor. The effect of axial strain on the critical current of the LLNL Nb{sub 3}Sn test strand was measured at magnetic fields from 8 T to 22 T. The conductor specifications are shown in Table 3, and the measured data are shown in Table 4. The data are presented graphically in Figs. 5 through 7. The I{sub c} and J{sub c} values are based on an electric field criterion (E{sub c}) of 2 {mu}V/cm. The zero-strain 12 T value of J{sub c} at 12 T was 0.39 GA/m{sup 2}. The irreversible strain limit was quite high, 1.0 strain, and the compressive prestrain was relatively low at 0.27%. Fracture strain was 1.10%.

1994-01-01

230

Low-cost FPSO for service in the Zaafarana oil field  

Energy Technology Data Exchange (ETDEWEB)

The Zaafarana oilfield development, operated by Zaafarana Oil Co. (Zafco) presented a series of unique challenges, including redeployment of an internal-turret mooring system, use of a turret-based electrical-cable jumper system, and permanent use of cable-deployed electric submersible pumps in the gravel-pack well completions. Following a detailed three-dimensional (3D) seismic program, the field was discovered by the first well in December 1990. Four subsequent appraisal wells were drilled. The discovery well and two of the appraisal wells tested oil at rates ranging from 2,000 to 10,100 B/D. Initial development plans called for the use of two conventional platforms with a pipeline to a shore-based treatment and storage terminal. Data acquired from subsequent wells were incorporated into the mapping and reserve estimates resulting in a sharp downgrade of the estimated recoverable reserves. The reduced estimate, combined with a revised pricing ...

1997-04-01

231

Life evaluation of insulating materials for electric cable by accelerated thermal-radiation combined aging. 2  

International Nuclear Information System (INIS)

Radiation-and-thermal-combined degradation of some kinds of cable insulating and jacketing materials was evaluated by accelerated aging tests. Plasticized polyvinyl chloride (PVC), silicone rubber, crosslinked and non-crosslinked halogen-free flame-retardant polyolefins (NH-XLPO and NH-PO) and ethylene-propylene rubber (EP rubber) of experimental formulation were degraded at accelerated rates, that are 50-1000 times the degradation rate under standard conditions (e.g.; 1Gy/h, 50degC), and a method to assess the lifetime of these materials under standard conditions was studied. The degradation was investigated by measuring tensile properties. In the accelerated aging tests, rates of elongation decrease owing to degradation for these materials were in proportion to the increase in accelerated rate. The PVC lifetime estimated from sequential aging tests had a tendency to extend beyond that from simultaneous aging tests, while the lifetime of other materials estimated ...

1994-01-01

232

Life evaluation of insulating materials for electric cable by accelerated thermal-radiation combined aging  

Energy Technology Data Exchange (ETDEWEB)

Radiation-and-thermal-combined degradation of ethylene-propylene rubber (EP rubber) and chlorosulfonated polyethylene (CSM) as cable insulating and jacketing materials were evaluated by accelerated aging tests and a method to assess the lifetime of these materials under practical application was studied. EP rubber and CSM of experimental formulation were degraded at accelerated rates, that are 50 [approx] 1000 times the degradation rate under a standard condition (1Gy/h, 50degC). The degradation was investigated by measuring the tensile properties. In the accelerated aging tests, rates of elongation decrease owing to degradation for both EP rubber and CSM were in proportion to increase in accelerated rate. Behaviors of elongation changes showed little difference with accelerated rate. EP rubber lifetime estimated from sequential aging test had a tendency to extend beyond that from simultaneous aging test, while CSM lifetime estimated from both aging tests were ...

1992-10-01

233

Life evaluation of insulating materials for electric cable by accelerated thermal-radiation combined aging  

International Nuclear Information System (INIS)

Radiation-and-thermal-combined degradation of ethylene-propylene rubber (EP rubber) and chlorosulfonated polyethylene (CSM) as cable insulating and jacketing materials were evaluated by accelerated aging tests and a method to assess the lifetime of these materials under practical application was studied. EP rubber and CSM of experimental formulation were degraded at accelerated rates, that are 50 #approx# 1000 times the degradation rate under a standard condition (1Gy/h, 50degC). The degradation was investigated by measuring the tensile properties. In the accelerated aging tests, rates of elongation decrease owing to degradation for both EP rubber and CSM were in proportion to increase in accelerated rate. Behaviors of elongation changes showed little difference with accelerated rate. EP rubber lifetime estimated from sequential aging test had a tendency to extend beyond that from simultaneous aging test, while CSM lifetime estimated from both aging tests were ...

1992-01-01

234

Effect of antioxidants on aging of nuclear plant cable insulation  

International Nuclear Information System (INIS)

The effects of various antioxidants and antioxidant concentrations on the radiation and thermal stability of EPDM and XLPE polymers used for insulation of electric cable in nuclear power plants were measured. The objective was to determine if particular antioxidants could be identified as being especially effective for stabilization against radiation aging and combined thermal and radiation aging. Elongation to rupture was used as the measure of stability. Materials were irradiated to doses up to 2 MGy (200 Mrad) at a dose rate of 200 to 300 Gy/h in the Cobalt-60 Gamma Irradiation Facility at the University of Virginia. All of the antioxidants tested, which were known to provide excellent thermal stability, also provided good stability for radiation aging and combined thermal/radiation aging, although small differences between antioxidants were noted. No antioxidant or antioxidant combination was identified as being especially outstanding. Stabilization against ...

235

Dynamic Rating and Underground Monitoring System (DRUMS)  

Energy Technology Data Exchange (ETDEWEB)

Drums is an acronym for Dynamic Rating and Underground Monitoring System, with specific application to high-pressure pipe-type cable systems which are the predominant means of underground electric power transmission in the United States. The primary objective of this EPRI-sponsored feasibility study was to establish the technical feasibility of seven DRUMS functions and two novel DRUMS communication schemes. The seven DRUMS functions which monitor the system's vital and measurable parameters in real time and perform system diagnostics in the event of component deterioration, malfunction or failure are: Real Time Current Monitoring and Rating; Leak Detection and Location; Fault Location; Pothead Monitoring; Oil Monitoring; Pipe Protection; and Splice Monitoring. The two DRUMS communication schemes are internal to the pipe cable system. Mechanical Communication will use pressure pulses to transmit data along the system, while the ...

1991-07-01

239

Municipal Heat Wave Response Plans  

UK PubMed Central (United Kingdom)

Approximately 400 people die from extreme heat each year in the United States, and the risk of heat waves may increase as a result of global climate change. Despite the risk of heat-related morbidity...Full Text Available

2004-09-01

240

Mechanisms of heat transfer augmentaiton around the stagnation point of an impinging air jet laden with solid particles. Report 1. ; Evaluation procedure of heat transfer augmentaion due to unsteady heat conduction between laden particles and heat transfer surface. Koki niso shototsu funryu no yodomiten kinbo ni okeru dennetsu sokushin kiko. 1. ; Ryushi eno chokusetsu sesshoku netsuido ni yoru dennetsu sokushin koka no bunri hoho  

Energy Technology Data Exchange (ETDEWEB)

Several heat transfer augmentation mechanisms contribute to the heat transfer augmentation around the stagnation point in the gas-solid two-phase impinging jet flow. Among those contributions, that of heat exchange was numerically analyzed and characteristically elucidated by the unsteady direct contact heat conduction at the time of impingement between the laden particles and heat transfer surface. In other words, if the contact time is short between the particles and heat transfer surface, the former is heated by heat stored in the latter as a heat capacity. In such a region, the heat quantity to be transferred to the particles changes by not only the thermal property value (heat capacity multiplied by heat conduction coefficient) of ...

1991-05-25

241

Heat transfer. Fundamentals. 5. rev. ed.  

International Nuclear Information System (INIS)

This textbook contains the following main topics: Heat conductivity, convection, condensation and evaporation, radiation heat transfer and heat exchangers. It includes the physical foundations for all these aspects and many examples. (orig.)

244

ASME proceedings of the 31. national heat transfer conference: Volume 2. HTD-Volume 324  

Energy Technology Data Exchange (ETDEWEB)

This volume is divided into the following sections: (1) fundamentals of convection heat transfer; (2) fundamentals of heat transfer with impinging jets; and (3) fundamentals of heat transfer augmentation. Separate abstracts were prepared for most papers in this volume.

1996-12-31

245

Underground electric-power transmission-system environmental impact assessment  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy, Division of Electric Energy Systems, has undertaken to identify the environmental issues and potential impacts associated with the installation of underground electric power transmission systems. This study reports the results of investigations into the advanced cable technologies being considered for future underground applications, as part of the development oriented research program of the Division of Electric Energy Systems. While the technology involves a high level of sophistication, there are relatively few impacts to the environment that are potentially significant, and of these none are inherently non-mitigable. Route planning, system design, and methods of construction and accident response can be pursued in order to minimize impacts where strict constraints are appropriate.

1982-03-01

246

Selected topics in transient response of aerial lines to high-altitude electromagnetic pulse  

International Nuclear Information System (INIS)

Aerial lines or cables, as one mainly energy transport path of electronic system when illuminated by HEMP, has been often modeled by field-to-transmission line model. However, in many cases, authors too often encounter some confusing statements to the lines effects during experimental procedure. The aim of this paper is to present and discuss these cases, such as the electromagnetic environment above the ground plane, the contribution of the different electromagnetic field component to the induced current and voltage, variations of the load current for different line heights and ground conductivities etc. (authors)

2005-11-01

247

Kevlar, the 'universal fiber'. Properties and applications in industry, sports and recreation. Kevlar - die 'Alleskoenner-Faser'. Eigenschaften und Anwendung in Industrie, Sport und Freizeit  

Energy Technology Data Exchange (ETDEWEB)

This article gives a survey of the history, properties and applications of 'Kevlar' aramide fibers. For example, the 'Kevlar' para-aramide fiber is used in compound materials in ship-, aircraft- and vehicle construction. 'Kevlar' is used as a replacement for asbestos, for example in brakes, clutches and seals or as rubber reinforcement (tyres, conveyor belts, hoses). The aramide fibers also offer manufacturers of ropes, hawsers and cables a near ideal range of properties. (MM).

1988-12-01

248

Industrial processing of complex fluids: Formulation and modeling  

Energy Technology Data Exchange (ETDEWEB)

The production of many important commercial materials involves the evolution of a complex fluid through a cooling phase into a hardened product. Textile fibers, high-strength fibers(KEVLAR, VECTRAN), plastics, chopped-fiber compounds, and fiber optical cable are such materials. Industry desires to replace experiments with on-line, real time models of these processes. Solutions to the problems are not just a matter of technology transfer, but require a fundamental description and simulation of the processes. Goals of the project are to develop models that can be used to optimize macroscopic properties of the solid product, to identify sources of undesirable defects, and to seek boundary-temperature and flow-and-material controls to optimize desired properties.

1997-08-01

249

Electromagnetic coupling of high-altitude, nuclear electromagnetic pulses  

International Nuclear Information System (INIS)

We have used scale models to measure the predicted coupling of electromagnetic fields simulating the effects of high-altitude nuclear electromagnetic pulses (HEMP) on the interior surfaces of electronic components. Predictive tools for exterior coupling are adequate. For interior coupling, however, such tools are in their infancy. Our methodological approach combines analytical, computational, and laboratory techniques in a complementary way to take advantage of their separate strengths. Computer models are a promising tool, as they can be used to treat complex objects with arbitrary shapes, dielectrics, and cables, and multiple apertures. Laboratory tests can expand the domain of investigation even further.

1984-11-01

250

An estimate of the response of a telephone repeater to a wideband pulse using FAAT techniques  

Energy Technology Data Exchange (ETDEWEB)

The purpose of a FAAT analysis is to estimate the probability of system upset to an electromagnetic threat, for systems on which we have incomplete information. As an example of this process, we will discuss the response of part of a telephone repeater system to wideband transients. We first estimate the currents induced on above-ground and buried cables. After that, we describe the simple circuit we used to build a model of the amplifier and protective devices. Finally, we describe the scaling of the energy deposited in the electronics, including its nonlinear large-signal response, with the amplitude of the wideband waveforms.

1992-09-01

251

2000 MW HVDC link between England and France  

Energy Technology Data Exchange (ETDEWEB)

The HVDC link across the English Channel, which was brought into service in 1986, has several innovative features. Techniques used in its construction together with recent developments have consolidated the viability of HVDC links for a variety of applications. Outlines the main features of the scheme, including the benefits of interconnecting the British and French 400 kV AC power systems; integration of the UK converter system to the 400 kV AC grid; the DC submarine cables; convertor equipment (particularly the UK installation); and future HVDC developments. 6 refs.

1987-03-01

252

The onset conditions of enhancement of ice accumulation associated with heat-conducting plates located perpendicularly to heat-transfer surfaces; Part 1: Analysis for still water  

Energy Technology Data Exchange (ETDEWEB)

An analytical study of the ice-formation process associated with heat-conducting plates located perpendicularly to isothermally heated and cooled surfaces with some clearance is presented. It is proposed that the onset conditions, which describe whether the ice-volume fraction in a steady state is greater than or less than that without heat-conducting plates, are defined by the dimensionless distances between the heated/cooled walls and the heat-conducting plates. It is shown that the onset conditions are dependent on the pitch and the thickness of the heat-conducting plates and are less dependent on the thermal conductivity of the plates.

1994-07-01

253

The Effect of the Temperature to Which the Material is Heated ...  

Science.gov (United States)

... The Effect of the Temperature to Which the Material is Heated on the Process of Formation of Intermetallic Compounds in Magnetic Pulse Welding,. ...

1980-09-01

254

SPECIAL EDDY CURRENT PROBES FOR HEAT ...  

Science.gov (United States)

... Accession Number : ADD326926. Title : SPECIAL EDDY CURRENT PROBES FOR HEAT EXCHANGER INSPECTION. Corporate Author : ...

1986-11-01

256

Development of a geothermal heat pump. Final report  

Energy Technology Data Exchange (ETDEWEB)

In the development of a geothermal heat pump a water source heat pump was connected to a 1-1/2'' water line, 2200' long, buried in an endless loop 10' deep. The system is closed, circulating the same water continuously through the heat pump back to the field again. This water line 10' deep is the geothermal heat source. No matter how cold the air temperature gets on a winter day the water temperature to the heat pump will always be above 45/sup 0/F. This system has efficiently heated our house the past year using no supplemental heat.

1981-11-02

257

Failure modes of safety-related components at fires on nuclear power plants; Saekerhetsrelaterade systemkomponenters felmoder vid brand paa kaernkraftverk  

Energy Technology Data Exchange (ETDEWEB)

Probabilistic assessment methods can be used to identify specific plant vulnerabilities. Application of such methods can also facilitate selection among system design alternatives available for safety enhancements. The quality of assessment results is however strongly dependent on realistic and accurate input data for modelling of system component behaviour and failure modes during conditions to be assessed. Use of conservative input data may not lead to results providing guidance on safety upgrades. Adequate input data for probabilistic assessments seems to be lacking for at least failure modes of some electrical components when exposed to a fire. This report presents an attempt to improve the situation with respect to such input data. In order to take advantage of information in existing documentation of fire incident occurrences some of the lessons learned from the fire at Browns Ferry Nuclear Power Plant on March 22, 1975 are discussed in this report. Also a summary of results from ...

2000-03-01

258

Experience acquired in the carrying out of the long duration test on XLPE-insulated, mediumvoltage cable according to DIN VDE 0276; Erfahrungen bei der Umsetzung der Langzeitpruefung an VPE-isolierten MS-Kabeln nach DIN VDE 0276  

Energy Technology Data Exchange (ETDEWEB)

Long duration investigations on XLPE-insulated, medium-voltage cable have been intensively carried out by producers, institutes and users for decades. These tests have concentrated on cable ageing especially under the influence of water. About six years ago, a standard test procedure was developed based on comprehensive know-how. This test procedure is now included in DIN VDE 0276-620. In the following text, experience gained during testing and while performing tests in numerous laboratories is reported, and a summary of the test results is given. (orig.) [Deutsch] Langzeituntersuchungen an VPE-isolierten Mittelspannungskabeln, die sich mit der Alterung der Kabel, besonders unter dem Einfluss von Wasser beschaeftigen, wurden seit Jahrzehnten durch Hersteller, Institute und Anwender intensiv betrieben. Basierend auf diesem sehr umfangreichen Know-how wurde vor rd. sechs Jahren ein standardisiertes Pruefverfahren entwickelt, das heute Bestandteil ...

1997-06-30

259

Heat transfer augmentation in rod bundles near grid spacers  

International Nuclear Information System (INIS)

Heat transfer augmentation by straight grid spacers in rod bundles is studied for single phase flow and for post critical heat flux dispersed flow. The heat transfer effect of swirling grid spacers in single phase flow is also examined. Governing heat transfer mechanisms are analyzed, and predictive formulations are established. For single phase flow, the local heat transfer at a straight spacer and at its upstream or downstream locations are treated separately. 18 refs.

1980-01-01

260

Geothermal heat-pump systems of heat supply  

International Nuclear Information System (INIS)

The data on the multilayer operation of the objects, located in the climatic conditions of the central area of Russia and equipped with the geothermal heat-pumping systems of the heat supply are presented. The results of the analytical studies on evaluating the geothermal heat-pumping systems of the heat supply integration efficiency into the structure of the energy supply system, prevailing in the country, are presented

2004-06-01

261

Air-side flow and heat transfer in compact heat exchangers: A discussion of enhancement mechanisms  

Energy Technology Data Exchange (ETDEWEB)

The behavior of air flows in complex heat exchanger passages is reviewed with a focus on the heat transfer effects of boundary-layer development, turbulence, spanwise and streamwise vortices, and wake management. Each of these flow features is discussed for the plain, wavy, and interrupted passages found in contemporary compact heat exchanger designs. Results from the literature are used to help explain the role of these mechanisms in heat transfer enhancement strategies.

1998-10-01

262

Binary heat pump system. Binary heat pump system  

Energy Technology Data Exchange (ETDEWEB)

This technical report describes an outline, features, total energy efficiency, and specifications of binary heat pump system. A closed circuit distributed water heat source heat pump method is employed in the binary heat pump system. Since the circulating water, which is adjusted at a constant temperature, is used as the heat source of the indoor unit, a stable performance can be obtained regardless of outside atmospheric temperature. The binary heat pump system is mainly composed of a center heat pump unit, indoor heat pump unit, heat source water pipes, and circulating pump. The center heat pump unit and the indoor heat pump unit are connected with each other by the heat source water, and each unit can be operated independently. This ...

1993-11-30

263

Analysis and optimization of the heat transfer coefficient of a finned heat exchanger submitted to natural convection; Analise e otimizacao do coeficiente de transferencia de calor de um trocador aletado submetido a conveccao natural  

Energy Technology Data Exchange (ETDEWEB)

A heat transfer (condenser) of a domestic freezer was tested in a vertical channel in order to study the influence of the chimney effect in the optimization of the heat transfer coefficient. The variation of the opening of the channel, position and the heating power of the heat exchanger in the heat transfer coefficient was considered. The influence of the surface emissivity on the heat transfer by thermal radiation was studied with the heat exchanger testes without paint and with black paint. The air velocity entering the channel was measured with a hot wire anemometer. In order to evaluate the chimney effect, the heat exchanger was testes in a open ambient. This situation simulates its operational conditions when installed on the freezer system. The variables collected in the experimental procedures was gathered in the ...

1997-07-01

264

In the Loop : A look at Manitoba's geothermal heat pump industry  

International Nuclear Information System (INIS)

This booklet outlines the position of Manitoba's heat pump market with the objective of promoting the widespread use of geothermal heat pumps in the province. It makes reference to the size of the market, customer satisfaction with heat pumps, and opinion of key players in the industry regarding the heat pump market. The information in this booklet is drawn on market research and lessons learned in Europe and the United States. In October 2001, a group of key stakeholders in Manitoba's heat pump market attended an industry working meeting to address the issues of market barriers, market enablers and market hot buttons. Market barriers include the high cost of geothermal heat pumps, lack of consumer awareness, lack of consistent standards, and public perception that heat pumps are not reliable. Market enablers include the low and stable ...

265

A new method of heat transfer augmentation by means of foreign gas jet impingement in liquid bath  

International Nuclear Information System (INIS)

The authors discuss a two-phase two-component experimental system developed to study enhancement of heat transfer from a vertical chip size heater to surrounding liquid (Freon 113 or Ethanol) due to air jet impingement. Heat transfer coefficient was measured as function of jet velocity, heat flux and the distance between exit of jet tube and heated surface. The injector was placed very close to the hot surface. It was found that the heat transfer was notably enhanced with foreign gas impingement, especially in the cases of small temperature differences between wall and coolant. In fact for higher jet velocities the heat transfer coefficients tended to infinite while the temperature differences between wall and coolant were zero. The heat transfer coefficients decreased with the increasing of heat flux. High-speed camera ...

1985-10-01

266

Experimental investigation and modelling of heat capacity, heat of fusion and melting interval of rocks  

Energy Technology Data Exchange (ETDEWEB)

The heat capacity and heat of fusion were measured for a number of minerals using differential scanning calorimetry (DSC). The DSC measurements showed that the heat of fusion for the minerals is very low compared to the heat of fusion for pure crystalline phases reported elsewhere. A model for the melting behaviour of mineral materials in terms of melting interval, heat capacities and heat of fusion has been developed. The only model input is the chemical composition of the mineral material. The model was developed to be implemented in a detailed model of a cupola furnace, thus the focus for the development was not only precision but also to obtain a model that was continuous and differentiable. The model is based on several different submodels that each covers a part of the heating and melting of rocks. Each submodel is based on large ...

2003-11-28

267

Renewable energy technologies for federal facilities: Geothermal heat pump  

Energy Technology Data Exchange (ETDEWEB)

This sheet summarizes information on geothermal heat pumps (GHPs), which extracts heat from the ground in the winter and transfers heat to the ground in the summer. More than 200,000 GHPs are operating in US; they can reduce energy consumption and related emissions by 23 to 44% compared to air-source heat pumps. Opportunities for use of GHPs, requirements, and cost are described. Important terms are defined.

1996-05-01

268

Performance of a commercial heat pipe under operational conditions  

Energy Technology Data Exchange (ETDEWEB)

The performance of a commercial heat pipe was investigated both experimentally and theoretically. The effect of the temperature difference, the surface area ratio, and the operational conditions on the performance were studied. The heat flow rate and the vapor temperature were estimated on a ready-made commercial heat pipe. Its performance varied considerably with operational conditions. Theoretical consideration of a mathematical model and several nomographs are also presented. This work is applicable to the design and use of heat pipes in the field.

1983-04-01

269

Microwave heating: Industrial applications. (Latest citations from the NTIS bibliographic database). Published Search  

Energy Technology Data Exchange (ETDEWEB)

The bibliography contains citations concerning industrial uses and design of microwave heating equipment. Included are heating and drying of paper, industrial process heat, vulcanization, textile processing, metallurgical heat for sintering and ceramic manufacturing, food processing, and curing of polymers.(Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

1995-12-01

270

Heating and hot water: the installations; Chauffage et eau chaude: les installations  

Energy Technology Data Exchange (ETDEWEB)

This book brings recommendations and information on the choice and the operating of heating systems and domestic hot water production in order to better choose the house, to better use the heating and to preserve the environment. General notions on the different heating systems and their operating on the renewable energies used and the heating emitters offer advices for the purchase of a house. (A.L.B.)

2005-07-01

271

Heat transfer  

Energy Technology Data Exchange (ETDEWEB)

Heat transfer has emerged as a leading-edge technology supporting the rapid pace of developments in science and engineering ranging from energy production to electronic cooling. Subjects covered at the 6th UK National Conference on heat transfer held at Edinburgh from 15-16 September 1999 include: convection; boiling and evaporation; condensation; numerical techniques; heat exchangers; radiation and combustion; conduction; two-phase flow and heat transfer augmentation. Fifteen of the papers are abstracted here.

1999-07-01

272

Diffusion absorption heat pump. Diffusion-Absorptions-Waermepumpe  

Energy Technology Data Exchange (ETDEWEB)

The development of a gas-operated diffusion absorption heat pump for the heating of living spaces is described. By various improvement an energy efficiency of the prototypes of 1.5 was achieved. Structural alterations led to a lower overall height and lower production costs. The CFCs used in electric heat pumps were replaced by environmentally neutral ammonia. Compared with conventional gas heating systems, the CO2 output could be reduced by more than 30%. figs., tabs.

1992-02-01

273

Convective heat transfer in annular flow  

International Nuclear Information System (INIS)

Several aspects of heat transfer at the annular two phase flow regime are considered. Nucleate boiling is supposed to be absent. Theoretical solutions for cases of laminar and turbulent flow in the liquid film, respectively, are considered, when steam presence does not effect the heat transfer. Heat transfer in annular flows is also considered, where steam phase consists totally or partially of the so-called incondensable gas. In this case steam phase can be a considerable resistance to heat transfer.

1980-01-01

274

Thermal energy considerations on solar cavity wall building  

Energy Technology Data Exchange (ETDEWEB)

The dwelling is equipped with solar collectors which heat the air circulating in the cavity walls and the space beneath the floors. The thermal aspects of such a building are described. Heat balance, losses, heating by the sun in different seasons are described. Different measures taken to reduce the energy losses are described.

1983-02-01

275

Recovering heat from the cupola stack  

Energy Technology Data Exchange (ETDEWEB)

A brief survey is given of some ways in which heat, which would normally be lost from a cupola furnace, is being recovered, either as hot water, steam, or electricity. Examples are provided of heat-recovery systems in Germany, Italy, and America. (author).

1986-01-01

276

Program listing for heat-pump seasonal-performance model (SPM). [CNHSPM  

Science.gov (United States)

The computer program CNHSPM is listed which predicts heat pump seasonal energy consumption (including defrost, cyclic degradation, and supplementary heat) using steady state rating point performance and binned weather data. (LEW)

1982-06-30

277

Mushy state forming of magnesium alloy making use of resistance heating  

Energy Technology Data Exchange (ETDEWEB)

Feasibility of mushy state forming of magnesium alloys making use of resistance heating was examined. Magnesium alloys, AZ31, AZ61 and AZ91, were taken up as experimental materials and cylindrical billets with a diameter of 15 mm and a height of 20 mm were used for both resistance heating and forming experiments. Input heat control was applied to the billet heating and insertion of thin discs of austenitic stainless steel with a low thermal conductivity between the billet and copper electrodes was attempted in order to improve the efficiency of the billet heating. Results were summarized as follows. (1) Resistance heating by input heat control was successful to heat the billets to their respective mushy state. (2) Insertion of the discs was very helpful in heating the billets and realized the ...

2003-07-01

278

Influence of surface heat flux ratio on heat transfer augmentation in square channels with parallel, crossed, and V-shaped angled ribs  

Science.gov (United States)

The paper investigates the effect of the wall heat flux ratio on the local heat transfer augmentation in a square channel with two opposite in-line ribbed walls for Reynolds numbers from 15,000 to 80,000. The square channel composed of 10 isolated copper sections has a length-to-hydraulic diameter ratio of 20. The rib height-to-hydraulic diameter ratio is 0.0625 and the rib pitch-to-height ratio equals 10. Six ribbed side to smooth side wall heat flux ratios are studied for four rib orientations. The results show that the ribbed side wall heat transfer augmentation increases with increasing ribbed side to smooth side wall heat flux ratios, but the reverse is true for the smooth side wall heat transfer augmentation. The average heat transfer augmentation of the ribbed side and smooth side wall decreases slightly with increasing wall ...

1992-10-01

279

Heat Transfer Augmentation in Turbulent Impinging Jets.  

Science.gov (United States)

Heating and cooling by impinging jets is widely used in various engineering applications, due to the high heat transfer rates prevailing in the vicinity of the stagnation point. The authors have been able to utilize acoustically excited turbulence for the...

1979-01-01

280

Fourth Order Accurate Discretization for the Laplace and Heat Equations on Arbitrary Domains, with Applications to the Stefan Problem.  

Science.gov (United States)

In this paper, the authors first describe a fourth order accurate finite difference discretization for both the Laplace equation and the heat equation with Dirichlet boundary conditions on irregular domains. In the case of the heat equation, they use an i...

2004-01-01

281

Environmental and yield aspects of heat provision  

International Nuclear Information System (INIS)

The advantages of district heating as an environmental-friendly and energy-saving technique are reviewed. The role of district heating as part of the Dutch national plan to reduce the emission of acidification and greenhouse gases by respectively 50 and 25 percent is clarified. 12 Tabs. (A.S.).

1994-01-01

282

Cytoplasmic heat shock granules are formed from precursor particles and are associated with a specific set of mRNAs.  

UK PubMed Central (United Kingdom)

In heat-shocked tomato cell cultures, cytoplasmic heat shock granules (HSGs) are tightly associated with a specific subset of mRNAs coding mainly for the untranslated control proteins. This messenger...Full Text Available

1989-03-01

283

?Activation of the mitogen-activated protein kinase pathways by heat shock  

UK PubMed Central (United Kingdom)

In addition to inducing new transcriptional activities that lead within a few hours to the accumulation of heat shock proteins (Hsps), heat shock activates within minutes the major signaling transduction...Full Text Available

2002-04-01

284

Thermodynamic analysis of a hybrid geothermal heat pump system  

British Library Electronic Table of Contents (United Kingdom)

A thermodynamic analysis of a hybrid geothermal heat pump system is carried out. Mass, energy, and exergy balances are applied to the system, which has a cooling tower as a heat rejection unit, and system performance is evaluated in terms of coefficient of performance and exergy efficiency. The heating coefficient of performance for the overall system is found to be 5.34, while the corresponding exergy efficiency is 63.4%. The effect of ambient temperature on the exergy destruction and exergy efficiency is investigated for the system components. The results indicate that the performance of hybrid geothermal heat pump systems is superior to air-source heat pumps.

2011-01-01

285

The study of thermal characteristics of high temperature oven for atomic spectroscopy  

International Nuclear Information System (INIS)

We present a high temperature heat oven with merits of conventional heat pipe oven and study ots thermal characteristics. The oven consists of stainless steel body and heating part of three layers of ceramic tubes. We obtained the maximum temperature of about 1350. deg. C at the center which was measured by thermocouple and infrared thermometer. And we compared the heating characteristics in the cases of external heating and no extent heating. It was applied to self diffraction experiment in the samarium gas which was one of the high melting point material.

1997-11-01

286

Steady-state thermal and hydraulic calculation of steam generator considering heat transfer tube lengths  

Energy Technology Data Exchange (ETDEWEB)

The effect of heat transfer is described from heat exchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heat exchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heat exchange tubes neqlecting the changes of physical properties of water along the heat exchange tubes, will yield sufficiently accurate results.

1982-10-01

287

Steady-state thermal and hydraulic calculation of steam generator considering heat transfer tube lengths  

International Nuclear Information System (INIS)

The effect of heat transfer is described from heat exchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heat exchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heat exchange tubes neqlecting the changes of physical properties of water along the heat exchange tubes, will yield sufficiently accurate results. (author).

1982-01-01

288

Perturbation solution to heat conduction in melting or solidification with heat generation  

Science.gov (United States)

The Stefan problem involving a source term is considered in this technical note. As an example, planar solidification with time-dependent heat generation in a semi-infinite plane is solved by use of a perturbation technique. The perturbation solution is validated by reducing the problem to the case without heat generation whose exact solution is available. An application to the case with constant heat generation is presented, for which a closed-form solution is obtained. The effects of heat generation and Stefan number on the evolution of solidification are examined using the perturbation solution.

2010-04-01

289

Low temperature latent heat thermal energy storage - heat storage materials  

Energy Technology Data Exchange (ETDEWEB)

Heat-of-fusion storage materials for low temperature latent heat storage in the temperature range 0-120 C are reviewed. Organic and inorganic heat storage materials classified as paraffins, fatty acids, inorganic salt hydrates and eutectic compounds are considered. The melting and freezing behavior of the various substances is investigated using the techniques of Thermal Analysis and Differential Scanning Calorimetry. The importance of thermal cycling tests for establishing the long-term stability of the storage materials is discussed. Finally, some data pertaining to the corrosion compatibility of heat-of-fusion substances with conventional materials of construction is presented.

1983-01-01

290

Geothermal heat pump applications: Industrial/commercial  

Energy Technology Data Exchange (ETDEWEB)

The fastest rate of growth in the space conditioning market has been attributed to the application of geothermal heat pumps to the industrial and commercial markets. The author reviews and provides examples of the three most popular components of a large geothermal heat pump system: geothermal earth coupling, heat pumps and heat exchangers, and building side terminals. These components are applied to three example geothermal installations: a library, an office building, and a school. Examples of energy use before and after the installation of a geothermal space conditioning system are summarized. General design and cost guidelines and comments on the use of geothermal heat pump in these and similar applications are discussed.

1999-07-01

291

Overhead power lines: overheating and electrodynamic stresses; Lignes aeriennes: echauffements et efforts electrodynamiques  

Energy Technology Data Exchange (ETDEWEB)

The flow of current inside a conductor leads to its overheating. This conductor is also submitted to other climatic phenomena, such as wind, sun light and ambient temperature. The knowledge of this overheating is important to ensure a functioning temperature compatible with the materials used for the conductor manufacturing and with the dip of overhead power lines above the ground and buildings. On the other hand, according to the Laplace works, the flow of current inside parallel conductors induces electromagnetic forces inside them, proportional to the product of currents in both conductors. In the case of short-circuit between aerial power lines or between flexible cables, electrodynamical stresses (traction and flexion) are applied to insulators and holders and important swinging of the lines can be observed. These stresses can be extremely important and must be considered in the design of overhead lines. These two phenomena are analyzed in this chapter. (J.S.)

1997-05-01

292

Miniature x-ray source  

Energy Technology Data Exchange (ETDEWEB)

A miniature x-ray source utilizing a hot filament cathode. The source has a millimeter scale size and is capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature source consists of a compact vacuum tube assembly containing the hot filament cathode, an anode, a high voltage feedthru for delivering high voltage to the cathode, a getter for maintaining high vacuum, a connector for initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is fabricated from highly x-ray transparent materials, such as sapphire, diamond, or boron nitride.

2000-01-01

293

Dielectric-wall linear accelerator with a high voltage fast rise time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators  

Energy Technology Data Exchange (ETDEWEB)

A dielectric-wall linear accelerator is improved by a high-voltage, fast rise-time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators. A high voltage is placed between the electrodes sufficient to stress the voltage breakdown of the insulator on command. A light trigger, such as a laser, is focused along at least one line along the edge surface of the laminated alternating layers of isolated conductors and insulators extending between the electrodes. The laser is energized to initiate a surface breakdown by a fluence of photons, thus causing the electrical switch to close very promptly. Such insulators and lasers are incorporated in a dielectric wall linear accelerator with Blumlein modules, and phasing is controlled by adjusting the length of fiber optic cables that carry the laser light to the insulator surface.

1998-01-01

294

Dielectric-wall linear accelerator with a high voltage fast rise time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators  

Energy Technology Data Exchange (ETDEWEB)

A dielectric-wall linear accelerator is improved by a high-voltage, fast rise-time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators. A high voltage is placed between the electrodes sufficient to stress the voltage breakdown of the insulator on command. A light trigger, such as a laser, is focused along at least one line along the edge surface of the laminated alternating layers of isolated conductors and insulators extending between the electrodes. The laser is energized to initiate a surface breakdown by a fluence of photons, thus causing the electrical switch to close very promptly. Such insulators and lasers are incorporated in a dielectric wall linear accelerator with Blumlein modules, and phasing is controlled by adjusting the length of fiber optic cables that carry the laser light to the insulator surface. 12 figs.

1998-10-13

295

Development of uninterruptible power supply for CATV networks; CATV yo muteiden dengen kyokyuki no kaihatsu  

Energy Technology Data Exchange (ETDEWEB)

A UPS based on a line-interactive system for CATV (Cable TV) networks has been newly developed. An inverter of the UPS featuring a pure sine wave output and equipped with an uninterrupptible transfer switch made it possible to raise its reliability high and to reduce the uninterruptible transfer time from 50 {approx} 100 ms to only 3 ms. The expected life of 15 years and maintenance-free of the UPS were realized by monitoring and optimizing the operational conditions of lead-acid batteries, aluminum electrolytic capacitors and cooling fans. The use of rust- and weather- resistant painting methods for an outer box of the UPS also contributed to extend the life of the system. (author)

1998-12-25

296

A statistical evaluation of recent SSC conductors produced at IGC/ASI  

International Nuclear Information System (INIS)

One of the requirements for uniform field quality in the SSC dipole magnets is the consistency in the superconducting strand characteristics from start to finish to the production phase. As full scale production of strand and cable approaches, the consistency in performance of the early batches of conductor needs to be examined. A number of 300 mm billets have been manufactured at IGC with tight process controls. The performance of the final conductor in terms of piece lengths, current density, Cu/Sc ratio and wire diameter has been evaluated. The data are analyzed in order to understand the variations that are related to the conductor design and processing. In this paper the current density of the strand is examined over the length of the billet to determine inherent variability in the Nb/Ti alloy itself.

1990-09-24

297

A connecting coupling  

Energy Technology Data Exchange (ETDEWEB)

The flexible, insulated, single strand cables are electrically connected with a cylindrical polar tip (PN) by means of cylindrical and conical shafts for the polar tips, which enter the faces of the divided, multiwire strand, clamped by tension half couplings. The flat ends of the polar tips being joined are positioned in two concentric mandrel bushings, an internal fixed one and an external, axially movable bushing (PV). The internal bushing is rigidly attached to the end of the left polar tip and equipped with three or four rounded, radial openings, whose diameter is determined by the external diameter of the locking device hinges (ShF) of the connecting couplings. The right polar tip is equipped with an annular channel of trapezoidal section into which the locking device hinges enter. The external movable bushing on the right side has a conical turning and on the left, a cylindrical into which the cylindrical spring which holds the movable bushing in the extreme ...

1981-06-05

298

Workability and Heat Treatment Characteristics of Beta ...  

Science.gov (United States)

... Accession Number : ADD135317. Title : Workability and Heat Treatment Characteristics of Beta Titanium Alloy, Ti-15V-3Cr-3Sn-3Al,. ...

1986-04-01

299

Underground Mine Water Heating and Cooling Using Geothermal Heat Pump Systems  

Energy Technology Data Exchange (ETDEWEB)

In many regions of the world, flooded mines are a potentially cost-effective option for heating and cooling using geothermal heat pump systems. For example, a single coal seam in Pennsylvania, West Virginia, and Ohio contains 5.1 x 1012 L of water. The growing volume of water discharging from this one coal seam totals 380,000 L/min, which could theoretically heat and cool 20,000 homes. Using the water stored in the mines would conservatively extend this option to an order of magnitude more sites. Based on current energy prices, geothermal heat pump systems using mine water could reduce annual costs for heating by 67% and cooling by 50% over conventional methods (natural gas or heating oil and standard air conditioning).

2006-03-01

300

To Possibility of Usage of FMW Plasma Heating Scenarios in the ICR Frequency Range in the Torsatron Reactor  

International Nuclear Information System (INIS)

The problem of fast wave plasma heating in reactor-torsatron at the ICRF range in scenarios, optimal for fusion reactor, is numerically studied.

2006-01-01

301

Subcooled Flow Boiling in a Minichannel  

British Library Electronic Table of Contents (United Kingdom)

It has been considered that dry-out occurs easily in boiling heat transfer for a small channel, a mini- or microchannel, because the channel was easily filled with coalescing vapor bubbles. In the present study, the experiments of subcooled flow boiling of water were performed under atmospheric conditions for a horizontal rectangular channel for which the size is 1 mm height and 1 mm width, with a flat heating surface of 10 mm length and 1 mm width placed on the bottom of the channel. The heating surface has a top of copper heating block and is heated by ceramic heaters. In the high heat flux region of nucleate boiling, about 70-80% of the heating surface was covered with a large coalescing bubble and the boiling reached critical heat flux as observed by high-speed video. In the beginning ...

2011-01-01

302

Rural residential application of geothermal heat pump. Progress report  

Energy Technology Data Exchange (ETDEWEB)

The installation and performance of a water source heat pump in Minnesota are discussed. The operating cost was found to be higher than expected. (MHR)

1981-07-20

303

PROCEEDINGS OF THE 1966 HEAT TRANSFER AND FLUID ...  

Science.gov (United States)

... mass of gray gas by thermal radiation; An experimental study of the turbulent wake behind a cone at M = 5; Heat transfer augmentation by steady ...

304

NASA Technical Paper 3487 ... - NASA Technical Reports Server  

Science.gov (United States)

heat transfer augmentation was found to increase with decreasing length scale but no optimum length scale was found. Heat transfer augmentation due to turbu- ...

305

Metal Foam Heat Exchangers for Heat Transfer Augmentation from a Cylinder in Cross-Flow  

British Library Electronic Table of Contents (United Kingdom)

A numerical study has been conducted to examine the heat transfer from a metal foam-wrapped solid cylinder in cross-flow. Effects of the key parameters including the free stream velocity and characteristics of metal foam such as porosity, permeability, and form drag coefficient on heat and fluid flow are examined. Being a determining factor in pressure drop and heat transfer increment, the porous layer thickness is changed systematically to observe that there is an optimum layer thickness beyond which the heat transfer does not improve while the pressure drop continues to increase. This has been verified by the application of Bejan?s Intersection of Asymptotes method. Results have been compared to those of a finned-tube heat exchanger to observe much higher heat transfer rate with reasonab...

2011-01-01

306

Long-term storage of solar heat  

Energy Technology Data Exchange (ETDEWEB)

Stochastic models for the simulation of global radiation are discussed. Thermal transients in the ground are analyzed. The performance of buried-pipe storage and a space heating system with long-term storage is described.

1981-06-01

307

Heat-transfer augmentation in rod bundles near grid spacers  

International Nuclear Information System (INIS)

Heat-transfer augmentation by straight grid spacers in rod bundles is studied for single-phase flow and for post-critical heat flux dispersed flow. The heat transfer effect of swirling grid spacers in single-phase flow is also examined. Governing heat-transfer mechanisms are analyzed, and predictive formulations are established. For single-phase flow, the local heat transfer at a straight spacer and at its upstream or downstream locations are treated separately. The effect of local velocity increasing near swirling spacer is considered. For post critical heat flux (CHF) dispersed flow, the heat transfer by thermal radiation, fin cooling, and vapor convection near the spacer are calculated. The predictions are compared with experimental data with satisfactory agreement.

1982-01-01

308

Heat transfer augmentation of mixed convection through vortex shedding from an inclined plate in a vertical channel containing heated blocks  

Energy Technology Data Exchange (ETDEWEB)

A numerical analysis is made of the unsteady flow and heat transfer characteristics of mixed convection in a vertical block-heated channel with and without installing an inclined plate above an upstream block. Parameter studies including the inclined plate angle, Reynolds number (ranging from 260 to 530), and Grashof number (in the range of 0--3,200,000) on heat transfer performance have been explored in detail. The results show that the installation of an inclined plate in the vertical block-heated channel can effectively augment the blocks` heat transfer performance in the channel. This can be applied to heat exchangers.

1998-02-06

309

Glass-heat-pipe evacuated-tube solar collector  

Science.gov (United States)

A glass heat pipe is adapted for use as a solar energy absorber in an evacuated tube solar collector and for transferring the absorbed solar energy to a working fluid medium or heat sink for storage or practical use. A capillary wick is formed of granular glass particles fused together by heat on the inside surface of the heat pipe with a water glass binder solution to enhance capillary drive distribution of the thermal transfer fluid in the heat pipe throughout the entire inside surface of the evaporator portion of the heat pipe. Selective coatings are used on the heat pipe surface to maximize solar absorption and minimize energy radiation, and the glass wick can alternatively be fabricated with granular particles of black glass or obsidian.

1981-08-06

310

Fundamental study of heat transfer augmentation of tube inside surface by cascade smooth surface-turbulence promoters  

Science.gov (United States)

Fundamental study of heat transfer augmentation of tube inside surface by cascade smooth surface-turbulence promoters

1987-03-01

311

Device for energy-saving heating of fuel in the fuel supply for an internal combustion engine  

Energy Technology Data Exchange (ETDEWEB)

The invention concerns a device for the energy-saving heating of fuel in the supply pipe to an internal combustion engine to regain energy from the fuel itself, particularly but not exclusively for a Diesel engine. A part of the quantity of heat added to the fuel between the tank and the injection nozzles is given up by excess fuel not to the tank, but to the fuel lifted upstream of the injection pump. The device is characterised by the fact that it has a heat exchanger, which absorbs heat from the fuel at the level of the injection pump or upstream of it, and takes this to the fuel above the injection pump. The heat exchanger is preferably mounted upstream of a filter and close to it. A bridging pipe, which may be integrated in the heat exchanger, permits the heat exchanger to be short-circuited depending on the fuel temperature.

1981-02-10

312

Deuterium isotope effect on molar heat capacities and apparent molar heat capacities in dilute aqueous solutions: A multi-channel heat-flow microcalorimeter study  

International Nuclear Information System (INIS)

The molar heat capacities of chloroform, dichloromethane, methanol, acetonitrile, acetone, dimethyl sulfoxide, benzene, dimethylformamide, toluene, and cyclohexane, as well as their deuterated isotopologues, were measured using a multi-channel heat conduction TAM (Thermal Activity Monitor) III microcalorimeter. In addition, the apparent molar heat capacities of some of the associated dilute aqueous solutions (0.0039 i < 0.0210) were also measured. A temperature drop method from (298.15 to 297.15) K at 0.1 MPa was employed. The corresponding heat capacities were determined from the integration of the measured heat flow. The heat capacity results are shown to be in good to very good agreement with the available literature values. In addition, good correlations were obtained for the effect of isotopic substitution on both molar heat capacity ...

2008-11-01

313

DEPLOYABLE HEAT PDPE RADUATOR - NASA Technical Report Server (NTRS)  

Science.gov (United States)

Eninger, J. E.: "Menisci Coalesence as a Mechanism for Venting Noncondensible. Gas From Heat-Pipe Arteries", AIAA Paper No. 74-748. ...

314

COOLOD, Steady-State Thermal Hydraulics of Research Reactors  

International Nuclear Information System (INIS)

1 - Description of program or function: The COOLOD-N2 code provides a capability for the analyses of the steady-state thermal-hydraulics of research reactors. This code is a revised version of the COOLOD-N code, and is applicable not only for research reactors in which plate-type fuel is adopted, but also for research reactors in which rod-type fuel is adopted. In the code, subroutines to calculate temperature distribution in rod-type fuel have been newly added to the COOLOD-N code. The COOLOD-N2 code can calculate fuel temperatures under both forced convection cooling mode and natural convection cooling mode. A 'Heat Transfer package' is used for calculating heat transfer coefficient, DNB heat flux etc. The 'Heat Transfer package' is a subroutine program and is especially developed for research reactors in which plate-type fuel is adopted. In case of rod-type fuel, DNB heat flux is ...

315

Analysis of Rough Wall Turbulent Heating with Application to ...  

Science.gov (United States)

... roughness. Since T u'v' and q v'"F the heat transfer augmentation is the square root of the skin friction augmentation: - 1/2 (( St - ,Cf 0 ...

1979-01-01

316

Study on the application of a geothermal heat pump; Etude sur l`application d`une pompe a chaleur geothermique  

Energy Technology Data Exchange (ETDEWEB)

The heating system of the `Centre integre de mecanique industrielle de la Chaudiere`, in Saint-Georges, Quebec, is based on a solar wall and a geothermal heat pump with a glycol/water mixture circulating in 44 wells that are 100 m deep. With installation costs below $25 per sq.m, more than 85 per cent of the heating needs of the 9500 sq.m centre were supplied by geothermal power. The geothermal heat pump is composed of a well field and two 211-kW cooling units, each equipped with four coiled compressors. In winter, heat is pumped from the earth and in summer, a heat exchanger with control valves allows to heat to be dumped back into the earth. The monitoring and simulation of the system proved its efficiency, considering the climatic conditions in Quebec. The annual consumption of geothermal heating is 0.146 GJ per sq.m, ...

1996-12-01

317

Heat pumps in urban space heating systems: Energy and environmental aspects  

International Nuclear Information System (INIS)

A statistical survey is conducted of air pollution in the city of Rome (Italy) due to conventional building space heating systems burning fossil fuels. The survey identifies the annual consumption of the different fuels and the relative amounts of the various pollutants released into the atmosphere by the heating plants, e.g., sulfur and nitrogen oxides, carbon monoxide, etc. Comparisons are then made between the ratios of urban heating plant air pollutants produced per tonne of fuel employed and those for ENEL (Italian National Electricity Board) coal, oil and natural gas fired power plants, in order to demonstrate the better environmental performances of the utility operated energy plants. The building space heating system energy consumption and pollution data are then used in a cost benefit analysis favouring the retrofitting of conventional heating systems with ...

1991-01-01

318

Augmentation of heat transfer in heat conductive medium by electro-hydrodynamic effect  

Energy Technology Data Exchange (ETDEWEB)

A method of augmenting heat transfer in the interior of a fluid or from the interface of a solid in contact to a fluid by utilizing electro hydrodynamic (EHD) phenomena has the following advantages: the heat transfer can be effected by using a relatively small, light-weight high voltage source and some simple structural members; no vibration and noise are generated; the method has a control function to control heat transfer by adjustment of field and voltage; and this method is effective in cost-saving. It is mass transfer by the electric force caused by interaction between true charges or polarized charges in a fluid and external electric filed that plays an important role in most of such heat transfer augmentation methods by EHD. Examples of heat transfer augmentation by EHD phenomena include electricaly induced convection, contribution of EHD effect to heat ...

1988-04-20

319

PROBABILITY OF FAILURE OF THE TRUDOCK CRANE SYSTEM AT THE WASTE ISOLATION PILOT PLANT (WIPP)  

Energy Technology Data Exchange (ETDEWEB)

This probabilistic analysis of WIPP TRUDOCK crane failure is based on two sources of failure data. The source for operator errors is the report by Swain and Guttman, NUREG/CR-1278-F, August 1983. The source for crane cable hook breaks was initially made by WIPP/WID-96- 2196, Rev. O by using relatively old (1970s) U.S. Navy data (NUREG-0612). However, a helpful analysis by R.K. Deremer of PLG guided the authors to values that were more realistic and more conservative, with the recommendation that the crane cable/hook failure rate should be 2.5 x 10-6 per demand. This value was adopted and used. Based on these choices a mean failure rate of 9.70 x 10-3(1/yr) was calculated. However, a mean rate by itself does not reveal the level of confidence to be associated with this number. Guidance to making confidence calculations came from the report by Swain and Guttman, who stated that failure data could be described by lognormal distributions. This is ...

2000-05-01

320

Mitigating aging in CANDU plants  

Energy Technology Data Exchange (ETDEWEB)

Aging degradation is a phenomenon we all experience throughout life, both on a personal basis and in business. Many industries have been successful in postponing the inevitable impact on their related systems and components through programs to maintain long-term reliability, maintainability and safety. However, this has not always been the case for nuclear power. While all power plants are experiencing the world trend of increasing operating costs with age, few (if any) have been able to fully define the parameters that solve the aging equation, particularly in relation to major components. Inspection and preventive maintenance have not been effective in predicting life-limiting degradation and failure. In CANDU nuclear plants, utilities are taking a comprehensive approach in dealing with the aging problem. Programs have been established to identify the current condition and degradation mechanisms of critical components, the failure of which would impact negatively on station ...

1995-07-01

321

The two-dimensional Stefan problem with slightly varying heat flux  

Science.gov (United States)

The authors solve the two-dimensional stefan problem of solidification in a half-space, where the heat flux at the wall is a slightly varying function of positioning along the wall, by means of a large Stefan number approximation (which turns out to be equivalent to a small time solution), and then by means of the Heat Balance Integral Method, which is valid for all time, and which agrees with the large Stefan number solution for small times. A representative solution is given for a particular form of the heat flux perturbation.

1995-09-01

322

The adiabatic engine:Global developments  

Energy Technology Data Exchange (ETDEWEB)

This book presents papers on internal combustion engines. Topics considered include the influence of partial suppression of heat rejection on performance and emissions, duothermic combustion, turbochargers made of sintered silicon nitrides, heat flux, low heat rejection engines, exhaust energy recovery, combustion chamber insulation, computerized simulation, heat transfer, friction, hoop stress effects, and bonding ceramics and metals.

1986-01-01

330

Neutron star evolution with internal heating  

Science.gov (United States)

The thermal evolution predicted by current models of the superfluid-crust interaction is noted to

1989-01-01

334

Long- but not short-term heat acclimation produces an apoptosis-resistant cardiac phenotype: a lesson from heat stress and ischemic/reperfusion insults  

UK PubMed Central (United Kingdom)

Long-term heat acclimation (AC, 30d/34°C) is a phenotypic adaptation leading to increased thermotolerance during heat stress (HS, 2 h 41°C). AC also renders protection against...Full Text Available

2010-09-01

336

High temperature heat transfer augmentation  

International Nuclear Information System (INIS)

The heat transfer augmentation is reviewed in view of high temperature heat exchangers illuminating the contribution of radiative heat transfer. A number of means and/or devices are presented as well as the sophisticated concept which will be promoted to the extended applications in matured industries such as iron and steel, oir refinery, petro-chemical. It should be emphasized that the more creative and innovatory technology has to be promoted in order to stimulate and refresh the foregoing industries, recognizing the increasing importance of the energy resources.

1985-08-01

337

Heat transfer augmentation by interrupted surfaces - Experimental considerations  

International Nuclear Information System (INIS)

An experimental study was undertaken to determine for the turbulent regime the heat transfer and fluid flow characteristics of a heat exchange array of unperforated, and perforated brass plates with 33% of the plate area open. In both cases, the plates were aligned parallel to the flow direction. For the flow conditions examined, the results showed enhancement of heat transfer and friction factor for the perforated array.

1987-08-01

338

Heat stress upregulates chaperone heat shock protein 70 and antioxidant manganese superoxide dismutase through reactive oxygen species (ROS), p38MAPK, and Akt  

UK PubMed Central (United Kingdom)

Chinese hamster lung fibroblasts V79 cells were treated with heat stress for 4 weeks with short duration (15 min) heat shock every alternate day in culture. It was observed that Hsp...Full Text Available

2009-11-01

339

Heat recovery in foundries  

Energy Technology Data Exchange (ETDEWEB)

A great deal of energy is necessary to manufacture castings, the greater part of which is wasted. Some general instructions are given on how to keep this part as low as possible. This is discussed particularly using the example of a heat recovery plant for foundries, especially in the melting and cooling of castings with the use of cupola furnace stack gas to produce hot gas. Further variants for recovering heat from the individual stages of a foundry process are listed. There are data on using this heat in operation.

1982-01-01

340

Heat capacities and densities of electrolyte mixtures in aqueous solution - application to the determination of apparent molar heat capacities and volumes for potassium triiodide and dioxoneptunium(V) perchlorate  

Energy Technology Data Exchange (ETDEWEB)

Apparent molar heat capacities for KI[sub 3](aq) were determined from flow-microcalorimetric measurements of KI(aq) solutions containing dissolved iodine. From these, the conventional partial molar heat capacity C[sub p,2][sup [infinity

1993-05-01

342

Geothermal heat pumps - gaining ground in the UK and worldwide  

Energy Technology Data Exchange (ETDEWEB)

This 2001 edition of the guide to UK renewable energy companies examines the geothermal heat pump sector, and discusses the technology involved, installations of geothermal heat pumps, the activity in the UK market with increased interest in UK geothermal heat pump products from abroad, and developments in the building sector. The UK government's increased support for the industry including its sponsorship of the Affordable Warmth programme, and the future potential of ground source systems are discussed.

2001-07-01

343

Geothermal heat pumps - gaining ground in the UK and worldwide  

International Nuclear Information System (INIS)

This 2001 edition of the guide to UK renewable energy companies examines the geothermal heat pump sector, and discusses the technology involved, installations of geothermal heat pumps, the activity in the UK market with increased interest in UK geothermal heat pump products from abroad, and developments in the building sector. The UK government's increased support for the industry including its sponsorship of the Affordable Warmth programme, and the future potential of ground source systems are discussed.

344

Geothermal heat pump  

Energy Technology Data Exchange (ETDEWEB)

Ground water ranging in temperature from only 38/sup 0/ to 140/sup 0/F can supply a considerable amount of heat energy when couple with a geothermal or ground-water heat pump. The heat pump's method of operation is examined as well as its performance characteristics. (MHR)

1982-12-01

346

Experimental investigation for fluid flow and heat transfer in a rotating tube with twisted-tape inserts  

Energy Technology Data Exchange (ETDEWEB)

Experimental investigation was carried out for friction factor and heat transfer coefficient in the case of a rotating tube with a twisted-tape insert for heat transfer augmentation. The data obtained were compared with existing data for a stationary tube with a twisted-tape insert. It has been observed that the enhancement in heat transfer offsets the rise in friction factor due to rotation, with respect to a plain tube under stationary conditions. A correlation has been proposed for the data obtained.

1995-04-01

356

Time-dependent fluid flow and heat transfer around a circular heated cylinder embedded in a horizontal packed bed of spheres  

Science.gov (United States)

The present study numerically investigates the enhancement of forced convective heat transfer from a single circular cylinder embedded in a packed bed of spherical particles confined by two impermeable parallel plates. The heat transfer results from the heated cylinder, with and without the presence of a porous medium, are compared. The results show that the presence of the porous particles enhances the heat transfer from the cylinder; however, the significant heat transfer augmentation is produced at high Re due to the effect of thermal dispersion. In addition, the effect of Re on Nut is much greater than that of kr and Bi in the porous channel. It is also found that the %?p is much higher than %HTE producing from packing the empty channel.

2010-05-01

357

The thermal response of an infinite line of open loop wells for ground coupled heat pump systems  

British Library Electronic Table of Contents (United Kingdom)

Ground thermal energy storage is a means of storing thermal energy underground during the summer and utilizing it during the winter. The main use of such a technology is in the heating, ventilating and air conditioning sector where the ground provides a stable temperature reservoir for a heat pump system. Heat pumps are mechanical systems that provide heating to a space in the winter, and cooling in the summer. They are increasingly popular because the same system provides both heating modes, depending on the direction of the cycle upon which they operate. The stable temperature reservoir allows the heat pump system to run at a higher efficiency. Thermal energy is transmitted to and from the ground by circulation of water through standing column geothermal wells. In commercial applications...

2011-01-01

358

The temporal evolution of coronal loops observed by GOES-SXI  

CERN Document Server

We study the temporal evolution of coronal loops using data from the Solar X-ray Imager (SXI) on board of GOES-12. This instrument allows us to follow in detail the full lifetime of coronal loops. The observed light curves suggest three somewhat distinct evolutionary phases: rise, main, and decay. The durations and characteristic timescales of these phases are much longer than a cooling time and indicate that the loop-averaged heating rate increases slowly, reaches a maintenance level, and then decreases slowly. This suggests that a single heating mechanism operates for the entire lifetime of the loop. For monolithic loops, the loop-averaged heating rate is the intrinsic energy release rate of the heating mechanism. For loops that are bundles of impulsively heated strands, it is an indication of the frequency of occurrence of individual heating events, or ...

2006-01-01

359

The feasibility of using a septic tank as a heat source for geothermal heat pumps  

Energy Technology Data Exchange (ETDEWEB)

A geothermal heat pump (GHP) system with three ground coils was installed in a residence in northern Idaho with a portion of the ground heat exchanger wrapped around the residential septic tank. The septic coil provided a significant portion of the heating for the residence over the heating season. There was no evidence of the septic tank freezing up or failing to properly function. Utilizing a septic tank as a heat source for GHP systems is feasible design option if the septic tank is used on a full-time basis. However, the tank should be surrounded on all sides by a large amount of soil and/or insulated from the ground surface to ensure that ground temperatures near the tank remain warm during the winter.

1999-11-01

360

Quantum Thermodynamic Cycles and quantum heat engines  

CERN Document Server

In order to describe quantum heat engines, here we systematically study isothermal and isochoric processes for quantum thermodynamic cycles. Based on these results the quantum versions of both the Carnot heat engine and the Otto heat engine are defined without ambiguities. We also study the properties of quantum Carnot and Otto heat engines in comparison with their classical counterparts. Relations and mappings between these two quantum heat engines are also investigated by considering their respective quantum thermodynamic processes. In addition, we discuss the role of Maxwell's demon in quantum thermodynamic cycles. We find that there is no violation of the second law, even in the existence of such a demon, when the demon is included correctly as part of the working substance of the heat engine.

2006-01-01

361

Influence of turbulence parameters, Reynolds number, and body shape on stagnation-region heat transfer  

Energy Technology Data Exchange (ETDEWEB)

This experiment investigated the effects of free-stream turbulence intensity, length scale, Reynolds number, and leading-edge velocity gradient on stagnation-region heat transfer. Heat transfer was measured in the stagnation region of four models with elliptical leading edges downstream of five turbulence-generating grids. Stagnation-region heat transfer augmentation increased with decreasing length scale but an optimum scale was not found. A correlation was developed that fit heat transfer data for isotropic turbulence to within {+-}4 percent but did not predict data for anisotropic turbulence. Stagnation heat transfer augmentation caused by turbulence was unaffected by the velocity gradient. The data of other researchers compared well with the correlation. A method of predicting heat transfer downstream of the stagnation point was developed. 28 refs., 12 ...

1995-08-01

362

Influence of turbulence parameters, Reynolds number, and body shape on stagnation-region heat transfer  

International Nuclear Information System (INIS)

This experiment investigated the effects of free-stream turbulence intensity, length scale, Reynolds number, and leading-edge velocity gradient on stagnation-region heat transfer. Heat transfer was measured in the stagnation region of four models with elliptical leading edges downstream of five turbulence-generating grids. Stagnation-region heat transfer augmentation increased with decreasing length scale but an optimum scale was not found. A correlation was developed that fit heat transfer data for isotropic turbulence to within #+-#4 percent but did not predict data for anisotropic turbulence. Stagnation heat transfer augmentation caused by turbulence was unaffected by the velocity gradient. The data of other researchers compared well with the correlation. A method of predicting heat transfer downstream of the stagnation point was developed. 28 refs., 12 ...

1995-01-01

363

Experimental investigation of mixed convection heat transfer from longitudinal fins in a horizontal rectangular channel  

British Library Electronic Table of Contents (United Kingdom)

Mixed convection heat transfer from longitudinal fins inside a horizontal channel has been investigated for a wide range of modified Rayleigh numbers and different fin heights and spacings. An experimental parametric study was made to investigate effects of fin spacing, fin height and magnitude of heat flux on mixed convection heat transfer from rectangular fin arrays heated from below in a horizontal channel. The optimum fin spacing to obtain maximum heat transfer has also been investigated. During the experiments constant heat flux boundary condition was realized and air was used as the working fluid. The velocity of fluid entering channel was kept nearly constant (0.15win0.16m/s) using a flow rate control valve so that Reynolds number was always about Re=1500. Experiments were conducted...

2010-01-01

364

Design and Operation of a Novel Capillary Pumped Two-Loop System for Cooling of Electronic Devices  

British Library Electronic Table of Contents (United Kingdom)

Heat pipes, loop heat pipes (LHP), and capillary pumped loops (CPL) have already proven their potential to remove high heat fluxes from a small electronic device and transport the heat to a heat sink that is large enough to transfer it into the ambient air. We introduce a novel two-loop system similar in design to CPLs but with an additional buoyancy-driven fluid loop. Non-degassed methanol is used as a working fluid. Key benefits compared to LHPs and CPLs are easy filling procedure, easy startup, and the tolerance toward noncondensable gases in the fluid. The amount of fluid in the system can be varied over a broad range without affecting the heat transfer performance. Three different inverted-meniscus-type evaporators have been employed in this study. A maximum evaporator heat transfer r...

2012-01-01

365

Basic study on heat transfer characteristics of liquid Na in a decay-heat removal system of LMFBR  

Energy Technology Data Exchange (ETDEWEB)

A numerical analysis is performed to clarify the heat transfer characteristics of combined convection around the tubes which form a single row perpendicularly arranged to a forced flow in the direction of gravity. A boundary-fitted coordinate transformation technique is adopted to solve the governing equations numerically. It is found in the case of liquid sodium that gravity-induced flow gives no substantial effect to heat transfer augmentation in a low Reynolds number region while it can be sufficiently expected in the ordinary fluids in the same Reynolds number region. This means that such heat transfer augmentation as expected in ordinary fluids can not be realized when crossflow-type heat exchangers installed for decay-heat removal operates in a low Reynolds number region.

1988-02-01

366

A study of binary mixture boiling: boiling site density and subcooled heat transfer  

Energy Technology Data Exchange (ETDEWEB)

(Boiling site densities and heat-transfer coefficients have been measured for ethanol-water and ethanol-benzene mixtures at 1.01 bar for a heated vertical brass disk. A strong effect of composition on the boiling site density was observed, which was attributed to the nature of the activation of the boiling surface and mass diffusion effects. The boiling heat-transfer coefficient was found to decrease with increasin subcooling, but for the mixtures at a given level of subcooling the decrease was less than that for the single components and azeotropic mixtures.) The heat-transfer coefficient at a given heat flux was seen to be quite insensitive to the very large increase in boiling site density in comparing the pure water and the ethanol-water azeotrope results, leading one to question pool boiling models that predict heat-transfer rates on the basis of boiling ...

1985-05-01

367

A parametric study on the exergoeconomic assessment of a vertical ground-coupled (geothermal) heat pump system  

Energy Technology Data Exchange (ETDEWEB)

An exergoeconomic model of a vertical ground-source heat pump residential heating system presented in this study uses exergy and cost energy mass (EXCEM) methods. The data obtained from a ground-source heat pump (GSHP) residential heating system installed at the Solar Energy Institute, Ege University, Turkey, are utilized for calculations at different reference temperature values in the range 0-25{sup o}C. The performance of the geothermal heat pump residential heating system is evaluated to indicate how exergoeconomic parameter values change with system. We also undertake a parametric study to investigate how varying reference temperatures will affect the exergoeconomic analysis of the GSHP system. A correlation between the ratio of thermodynamic loss rate to capital cost and reference state temperature is developed. (author)

2007-03-15

368

A metal matrix for heat transfer enhancement during phase-change processes  

Energy Technology Data Exchange (ETDEWEB)

A metal matrix is inserted into a phase-change material to enhance the heat transfer during phase-change processes. The metal matrix tends to act like a heat transfer fin from the heated or cooled surface and to increase the effective thermal conductivity of the phase-change fluid. The scope of the study involves numerically modeling the heat transfer to and from constant-temperature cylindrical tubes surrounded by water during the freezing and melting processes. Comparisons of heat transfer with and without the metal matrix are made, with different porosities and densities of the metal matrix being examined. The results of this study are discussed in terms of the effectiveness of the metal matrix as a heat transfer enhancement device.

1994-12-31

369

A basic study on heat transfer characteristics of liquid Na in a decay-heat removal system of LMFBR  

International Nuclear Information System (INIS)

A numerical analysis is performed to clarify the heat transfer characteristics of combined convection around the tubes which form a single row perpendicularly arranged to a forced flow in the direction of gravity. A boundary-fitted coordinate transformation technique is adopted to solve the governing equations numerically. It is found in the case of liquid sodium that gravity-induced flow gives no substantial effect to heat transfer augmentation in a low Reynolds number region while it can be sufficiently expected in the ordinary fluids in the same Reynolds number region. This means that such heat transfer augmentation as expected in ordinary fluids can not be realized when crossflow-type heat exchangers installed for decay-heat removal operates in a low Reynolds number region. (author).

1988-01-01

370

Study of heat reinjection mechanism of a direct-injection diesel engine. 2nd Report. Effects of combustion control item on heat flux; Chokufun diesel kikan no nensho shitsunai netsu sonshitsu no mechanism ni kansuru kenkyu. 2. Nenshokei parameter no netsu nagare eno eikyo  

Energy Technology Data Exchange (ETDEWEB)

Experimental investigations are being conducted on a single-cylinder direct-injection diesel engine to examine the effects of combustion chamber specifications and swirl ratios on the heat release and transient heat transfer characteristics. Heat rejection was examined on the basis of heat release calculations using cylinder pressure time histories. Transient surface temperature data obtained from stationary locations in the piston and cylinder head were used as the basis for determining the transient heat flux rates. The results showed good agreement with the heat rejection calculated from cylinder pressure data and that transient heat flux in a piston cavity was reduced with the larger cavity diameter and a higher swirl ratio. On the other hand, a transient heat flux in a piston head was not changed by the cavity ...

1997-09-25

371

Status of non-electric nuclear heat applications: Technology and safety  

International Nuclear Information System (INIS)

Nuclear energy plays an important role in electricity generation, producing 16% of the world's electricity at the beginning of 1999. It has proven to be safe, reliable, economical and has only a minimal impact on the environment. Most of the world's energy consumption, however, is in the form of heat. The market potential for nuclear heat was recognized early. Some of the first reactors were used for heat supply, e.g. Calder Hall (United Kingdom), Obninsk (Russian Federation), and Agesta (Sweden). Now, over 60 reactors are supplying heat for district heating, industrial processes and seawater desalination. But the nuclear option could be better deployed if it would provide a larger share of the heat market. In particular, seawater desalination using nuclear heat is of increasing interest to some IAEA Member States. In consideration of the ...

372

Control of anodic passivation systems  

Energy Technology Data Exchange (ETDEWEB)

A method is described of controlling an anodic protection system in a heat exchanger comprising: (a) installing at least one cathode within the heat exchanger, at least one cathode being aligned with the longitudinal axis of the heat exchanger and extending substantially along the length of the heat exchanger; (b) installing a first reference electrode within and at one end of the heat exchanger, the first reference electrode having a first controller having a set point for control and a power supply having an output creating an electrical potential between at least one cathode and the heat exchanger; (c) measuring the electrical potential of the heat exchanger with the first reference electrode; (d) operating the first controller in response to measurements made by the first reference electrode to change the output of the power supply; (e) ...

1987-08-25

373

Competition advantage by utilizing the gross calorific value-high potential for the local heat supply; Wettbewerbsvorsprung durch Brennwertnutzung. Hohes Potential bei der Nahwaermeversorgung  

Energy Technology Data Exchange (ETDEWEB)

The gross calorific value (H{sub o}) is the amount of heat which is generated by total combustion of a type of fuel. It also includes that part of heat which is generated by steam from evaporated water contained in heating gas. In conventional heating boilers, this heat portion is not being utilized at all. To utilize the gross calorific value, it is necessary to extract from the exhaust gas the evaporation heat bound in steam and to return this to the heating system. This means that the exhaust gas has to be chilled by the return water of the heating system and condensed in suitable heat exchangers to well below the dew point. (orig.) [Deutsch] Waermelieferanten im Bereich der Nahwaermeversorgung koennen durch die Anwendung verfuegbarer und bewaehrter Brennwerttechnik ihre Kosten senken und einen ...

1999-01-01

374

Boiling heat transfer in a small horizontal rectangular channel  

Energy Technology Data Exchange (ETDEWEB)

Compact heat exchangers have traditionally found wide application in the transportation industry, where they are used as evaporators and condensers in vapor compression cycles for air conditioning and refrigeration. Such heat exchangers possess numerous attractive features including high thermal effectiveness, small size, low weight, design flexibility, and pure counterflow, and they can accommodate multiple streams. Today, there is a widespread interest in expanding the range of application of compact heat exchangers to include phase-change heat transfer in the process industries, among others. An overall objective of this effort is to provide the basis for establishing design technology in this area. In the present study, small channel flow boiling heat transfer was extended to a rectangular channel (4.06 {times} 1.70 mm) using refrigerant 12 (R-12). As with the circular tube ...

1993-08-01

375

Air-side performance of a parallel-flow parallel-fin (PF{sup 2}) heat exchanger in sequential frosting  

Energy Technology Data Exchange (ETDEWEB)

The thermal-hydraulic performance in periodic frosting conditions is experimentally studied for the parallel-flow parallel-fin heat exchanger, henceforth referred to as a PF{sup 2} heat exchanger, a new style of heat exchanger that uses louvered bent fins on flat tubes to enhance water drainage when the flat tubes are horizontal. Typically, it takes a few frosting/defrosting cycles to come to repeatable conditions. The criterion for the initiation of defrost and a sufficiently long defrost period are determined for the test PF{sup 2} heat exchanger and test condition. The effects of blower operation on the pressure drop, frost accumulation, water retention, and capacity in time are compared under the conditions of 15 sequential frosting cycles. Pressure drop across the heat exchanger and overall heat transfer coefficient are quantified under frost conditions as ...

2010-09-15

376

The effect of the shear rate-dependent thermal conductivity of non-Newtonian fluids on the heat transfer in a pipe flow  

Science.gov (United States)

The present study investigates the effect of the shear rate-dependent thermal conductivity of non-Newtonian fluids on the heat transfer enhancement in a pipe flow. The constant heat flux as thermal boundary condition was adopted in the thermally developed region. The present analytical results show the heat transfer enhancement over those of a shear rate-independent thermal conductivity fluid. The heat transfer coefficient ratio (h/h{sub 0}) linearly increase with the non-dimensional average velocity difference which is the product of the shear rate-dependence of the thermal conductivity and wall-shear rate.

1996-09-01

377

Nonlinear dynamics of heat transfer enhancement using eddy promoters  

Science.gov (United States)

This investigation concerns the nonlinear dynamics of heat transfer from a surface using an upstream eddy promoter. A numerical model is developed for the coupled fluid flow and heat transfer process based on a modified MacCormack scheme. Numerical simulations are carried out to determine the response and heat transfer enhancement due to the promoter. The average heat transfer from a cavity floor is seen to be increased by a factor of approximately five over the unpromoted'' flow. Another interesting feature of the study is the nonlinear viscous flow dynamics from the cylinder-wall interaction which differ significantly from the familiar cylinder-free stream patterns.

1994-02-01

378

Nonlinear dynamics of heat transfer enhancement using eddy promoters  

Energy Technology Data Exchange (ETDEWEB)

This investigation concerns the nonlinear dynamics of heat transfer from a surface using an upstream eddy promoter. A numerical model is developed for the coupled fluid flow and heat transfer process based on a modified MacCormack scheme. Numerical simulations are carried out to determine the response and heat transfer enhancement due to the promoter. The average heat transfer from a cavity floor is seen to be increased by a factor of approximately five over the unpromoted'' flow. Another interesting feature of the study is the nonlinear viscous flow dynamics from the cylinder-wall interaction which differ significantly from the familiar cylinder-free stream patterns.

1994-02-01

379

Lack of oscillations in Dual-Phase-Lagging heat conduction for a porous slab subject to imposed heat flux and temperature  

Energy Technology Data Exchange (ETDEWEB)

This study shows that the physical conditions necessary for thermal waves to materialize in Dual-Phase-Lagging porous media conduction are not attainable in a porous slab subject to a combination of constant heat flux and temperature (Neumann and Dirichlet) boundary conditions. It is demonstrated that the approximate equivalence between Dual-Phase-Lagging (DuPhlag) heat conduction model and the Fourier heat conduction in porous media subject to Lack of Local Thermal Equilibrium (La Lotheq) that suggested the possibility of thermal oscillations and resonance reveals a condition that cannot be fulfilled because of physical constraints. (author)

2005-07-01

380

Heat transfer equipment design  

Energy Technology Data Exchange (ETDEWEB)

A comprehensive presentation is made of state-of-the-art configurations and design methodologies for heat transfer devices applicable to industrial processes, automotive systems, air conditioning/refrigeration, cryogenics, and petrochemicals refining. Attention is given to topics in heat exchanger mechanical design, single-phase convection processes, thermal design, two-phase exchanger thermal design, heat-transfer augmentation, and rheological effects. Computerized analysis and design methodologies are presented for the range of heat transfer systems, as well as advanced methods for optimization and performance projection.

1988-01-01

381

Heat rejection system  

Energy Technology Data Exchange (ETDEWEB)

A cooling system for rejecting waste heat consists of a cooling tower incorporating a plurality of coolant tubes provided with cooling fins and each having a plurality of cooling channels therein, means for directing a heat exchange fluid from the power plant through less than the total number of cooling channels to cool the heat exchange fluid under normal ambient temperature conditions, means for directing water through the remaining cooling channels whenever the ambient temperature rises above the temperature at which dry cooling of the heat exchange fluid is sufficient and means for cooling the water. 5 figs.

1980-01-22

382

Borehole heat store design optimization. The SmartStore model  

Energy Technology Data Exchange (ETDEWEB)

The SmartStore model was developed to determine the optimum design of borehole heat stores as a function of different design parameters. The optimum design is defined as the design that achieves the storage task with a minimum annual storage cost. The annual storage cost is the sum of annual costs of investment, operation, maintenance and heat loss. The PC-model has a user-friendly lay-out and gives a fast pre-design of borehole heat stores. In this article the model is briefly described. It is also shown that the technical design of the store is influenced by varying technical properties of the storage volume, but also by the cost of heat. (orig.)

1994-12-31

383

Analysis of laminar flow and heat transfer in the entrance region of an internally finned concentric circular annular duct  

Energy Technology Data Exchange (ETDEWEB)

The concentric circular annular duct is a common geometry in many fluid flow and heat transfer devices. For the purpose of heat transfer augmentation, fins are often employed in the annular region, and such finned ducts find wide application in compact heat exchangers (5, 6). The analysis of flow and heat transfer in this geometry is, therefore, quite important from an engineering standpoint. For fully developed conditions, the problem has already been analyzed (7-10). However, no results are available for the developing flow in the entrance region. It is with this latter problem that the present paper is concerned.

1987-05-01

384

Analysis of a bayonet tube heat exchanger  

Energy Technology Data Exchange (ETDEWEB)

This paper details the design, construction and testing of a bayonet tube heat exchanger for use in the process industry and potentially as part of an externally fired combined cycle. Detailed analysis of the system has been undertaken, in particular on the tube side. The data is reported in terms of temperature, pressure, heat gain and heat exchanger effectiveness, over a range of Reynolds numbers and shell side mixture ratios. Much of the heat gained by the tubes is in the annular flow of the bayonet tube. Overall the effectiveness of this system could exceed 70%. (Author)

2001-01-01

385

Heat pipe cooled piston - feasibility study  

Energy Technology Data Exchange (ETDEWEB)

This study assesses the feasibility of the so-called heat pipe technique for cooling the piston of a mediumspeed diesel engine and is part of a research project 'EVE HPD, Extreme Value Engine Tests with High Power Density' carried out by HUT Internal Combustion Engine Laboratory. Diesel engines are being developed to give greater power from a given cylinder swept volume, which means higher temperatures in combustion chamber. The traditional oil cooling cannot be used beyond certain temperature level. Heat pipe technology could provide one solution to the cooling problem. The general properties, principles of operation, and structures of different types of heat pipes are described. Working fluids and container materials of heat pipes are discussed. The operation limitations of heat pipes are studied, especially, the limitations of a reciprocating ...

2004-07-01

386

Integration of SPECT with CT to plan radiotherapy fields. n application to conformal irradiation for lung carcinoma; Integrazione delle immagini della Tomografia Computerizzata con emissione di fotone singolo in un sistema commerciale per l'elaborazione dei piani di radioterapia. Applicazione all'irradiazione conformazionale del carcinoma polmonare  

Energy Technology Data Exchange (ETDEWEB)

Single photon emission computed tomography (SPECT) of lung perfusions permits to map functioning lung parenchyma with higher sensitivity than CT. Delivering higher radiations doses it used to increase local control in lung carcinoma; this strategy is based on radiobiological and clinical studies. Lung parenchyma is a dose-limiting tissue in patients irradiated for lung cancer. Functional mapping based on SPECT and CT findings permits to design radiation beams such as to minimize irradiation of functioning lung. [Italian] L'integrazione delle immagini diagnostiche aventi diverso contenuto informativo anatomico-funzionale puo' essere utilizzata nella radioterapia per migliorare le procedure diagnostiche e ottimizzare la geometria dell'irraggiamento. I sistemi per l'elaborazione di piani di radioterapia oggi in uso sono direttamente interfacciati con gli apparecchi di Tomografia Computerizzata (TC) e l'impiego di immagini provenienti da altre ...

1999-04-01

387

Use of solar assisted geothermal heat pump and small wind turbine systems for heating agricultural and residential buildings  

Energy Technology Data Exchange (ETDEWEB)

The main objective of the present study is twofold: (i) to analyze thermal loads of the geothermally and passively heated solar greenhouses; and (ii) to investigate wind energy utilization in greenhouse heating which is modeled as a hybrid solar assisted geothermal heat pump and a small wind turbine system which is separately installed in the Solar Energy Institute of Ege University, Izmir, Turkey. The study shows 3.13% of the total yearly electricity energy consumption of the modeled system (3568 kWh) or 12.53% of the total yearly electricity energy consumptions of secondary water pumping, brine pumping, and fan coil (892 kWh) can be met by using small wind turbine system (SWTS) theoretically. According to this result, modeled passive solar pre heating technique and combined with geothermal heat pump system (GHPS) and SWTS can be economically preferable to the conventional space ...

2010-01-15

388

Study of solution for issues of an optimum operating plan in heat storing system; Chikunetsu system ni okeru saiteki un`yo keikaku mondai no kaiho ni taisuru ichikosatsu  

Energy Technology Data Exchange (ETDEWEB)

An approximate solution was proposed in which a sensitivity analysis by the storage and release of heat was performed for the subject issues and in which an operating method was thereby determined for the equipment constituting the system by means of a linear programming. Accordingly, a heat storage type energy supply system for a district cooling and heating was taken up as a concrete object to be examined. This system consisted of a gas turbine generator, initial power receiving equipment, gas boiler, electric heat pump for ice heat storage, cooling tower, heat exchanger, steam absorbing refrigerating machine, ice heat storage tank, cold and warm water heat storage tank, etc. As a result of comparison between the proposed method and the resolving method, the former showed -0.92 to 2.58% in the increase in the operating ...

1996-02-01

389

Study of heat rejection mechanism of a direct-injection diesel engine. 1st Report. Characteristics of local heat flux; Study of heat reinjection mechanism of a direct-injection diesel engine. 1. Characteristics of local heat flux  

Energy Technology Data Exchange (ETDEWEB)

Experimental investigations are being conducted on a single-cylinder direct-injection diesel engine to examine the transient heat transfer characteristics. Transient temperature data from stationary locations in the piston and cylinder head were used as the basis for determining the transient heat flux rates. Transient surface temperature was measured using the thin film thermocouples. At first, the transient heat flux rates calculated from the analysis method used in this paper were compared with the results from FEM. The results showed good agreement. Using this analysis method, the transient heat flux rates were calculated. The tests were performed at 1200 rpm with constant air flow. The parameters that were varied included the fuel rate and injection timing. Based on these results, the present paper discusses the mechanism of heat rejection in a direct-injection diesel engine. 8 ...

1997-09-25

390

Studies on improvement of heat transfer characteristics in high temperature heat exchangers, (1)  

International Nuclear Information System (INIS)

Reported in this paper are the theoretical and experimental studies, with regard to the effects of radiation between walls, conducted for the improvement of heat transfer characteristics of the circular duct in high temperature heat exchangers that operate through the medium of non-radiating gases at around 1,000"0C. To study the fundamental performance of the heat transfer augmentation, the experiment was carried out using a double tube at temperatures up to 900"0C. The outer tube in a double tube was selectively heated so as to give a uniform heat flux selected of 6.5 x 10"3 and 4.6 x 10"4 kcal/m"2.h, while the inner tube was used as a radiating surface to impart the radiation heat transmitted from the outer tube. Selectively preheated air was caused to flow in an annular passage at an inlet temperature selected within 100"0C to 400"0C and with the Reynolds ...

1978-01-01

391

Heating and cooling with geothermal energy: trends and accomplishments; Solutions de chauffage et de climatisation utilisant l`energie geothermique: tendances et realisations  

Energy Technology Data Exchange (ETDEWEB)

Recent developments in heat pump technology have made geothermal-based heat exchange systems particularly well-suited for the heating and cooling needs of buildings even in cold climates. The principles of geothermally-coupled heat pump heating and cooling systems were presented. Results of an in-situ study conducted by Hydro-Quebec on the efficiency of the geothermal heat pump system installed at the Saint-Hyacinthe professional school were summarized. This investigation was meant to be a case study of the applicability of these new technologies to the needs of the Quebec market. After the first year of service, the Saint-Hyacinthe system clearly demonstrated its cost effectiveness over conventional systems. It was predicted that geothermal heat pump systems will gain in popularity in Quebec because they can fully meet the ...

1996-03-01

392

Heat transfer in parallel plate duct with a sinusoidal wave plate uniaxially inserted (1st). Effect of wave length on heat transfer augmentation  

Energy Technology Data Exchange (ETDEWEB)

High-performance heat transfer augmentation methods applicable in the forced convection field of heat exchangers include a method which requires no external drive means, such as the insertion of a turbulence augmentation object into the flow passage and the use of a wave-shaped flow passage, but disturbs the main stream of flow to raise the heat transportation effect thereby to augment heat transfer in the flow passage. The heat transfer characteristics and thermal performance ratio achieved when sinusoidal-shape plates are inserted instead of augmentation objects, such as cylinders, with a high shape-induced resistance were studied. As a result, the relationship between the resistance coefficient, average Nusselt number, heat transfer coefficient, and pitch was clarified. It has been revealed that the use of eddies with a large gap flow and recirculation area ...

1988-09-01

393

Ground source heat for heat pumps; Erdgekoppelte Waermequellen fuer Waermepumpen  

Energy Technology Data Exchange (ETDEWEB)

Under the new name of ``geothermal heat pump``, ground-source heat pumps are currently high in demand in Northern America. In sectors characterized by heating and cold air demand, their advantages can be exploited to the full. For Germany, the end-use-energy substitution potential of geothermal heat pumps has been estimated at 1310-1470 PJ annually. Whether this potential can actually be exploited depends essentially on the development of energy prices, but also on the resourcefulness of plant and heat pump manufacturers in upgrading and cheapening geothermal heat pumps. (orig./RHM) [Deutsch] Unter der neuen Bezeichnung `Geothermal Heat Pump` erlebt die erdgekoppelte Waermepumpe z.Zt. in Nordamerika einen Verbreitungsschub. In dem durch Heiz- und Kuehlbedarf charakterisierten Umfeld kann sie Ihre Vorteile voll nutzen. Fuer Deutschland kommt ...

1996-12-31

394

Effect of coal rank and mineral matter on gasification reactivity of coal char treated at high temperature; Netsushorishita sekitan char no gas ka tokusei ni taisuru tanshu oyobi kobutsushitsu no eikyo  

Energy Technology Data Exchange (ETDEWEB)

In the wide range from brown coal to anthracite, an investigation was made of effects of heat treatment on physical/chemical properties and of coal rank dependence. For the experiment, 12 kinds of coal samples were used, and for heat treatment, the fluidized bed heated by the electric furnace and the infrared-ray gold image furnace were used. To examine characteristics of the heat-treated coal char, conducted were oxygen gasification, TPD measurement, XRD measurement, alkali metal measurement, and pore distribution measurement. The following were obtained from the experiment. The gasification reaction rate of the char heat-treated in the temperature range between 900{degree}C to 1700{degree}C decreases with a rise of the temperature of heat treatment, and the degree of decrease in the rate depends on coal rank. The order of gasification rate between coal ranks ...

1996-10-28

395

Core Heat Transfer Model Validation of the TASS/SMR-S Code using the Bennett's Test  

International Nuclear Information System (INIS)

The SMART (System-integrated Modular Advanced ReacTor) which is a 330 MWt advanced integral PWR was developed by the KAERI (Korea Atomic Energy Institute) for electricity generation and seawater desalination. A thermal hydraulic evaluation and analysis of the SMART is performed by the TASS /SMR-S (Transient And Setpoint Simulation/System integrated Modular Reactor-Safety). The TASS/SMR-S code has various models reflecting the design features of the SMART such as the drift flux model, the core models (core power and core heat transfer model), the component models, and the specific models. One of the core models is the core heat transfer model. The role of this model is to calculate the heat flux and radial temperature profiles at a fuel rod surface using the relevant heat transfer correlations for all of the heat transfer modes. Also it is modeled to meet the requirements of the 10 ...

2010-10-01

396

Comparative performance of two types of evacuated tube solar collectors in a residential heating and cooling system. The progress report  

Science.gov (United States)

Two types of evacuated tube solar collectors have been operated in space heating, cooling and domestic hot water heating systems in Colorado State University Solar House I. An experimental collector from Corning Glass Works supplied heat to the system from January 1977 through February 1978, and an experimental collector from Philips Research Laboratory, Aachen, which is currently in use, has been operating since August 1978. A flat absorber plate inside a single-walled glass tube is used in the Corning design, whereas heat is conducted through a single glass wall to an external heat exchanger plate in the Philips collector. In comparison with conventional flat-plate collectors, both types show reduced heat losses and improved efficiency. For space heating and hot water supply in winter, the solar delivery efficiency of the Corning collector ...

1979-01-01

397

CFD simulation of flow distribution in the header of plate-fin heat exchangers  

Energy Technology Data Exchange (ETDEWEB)

The flow distribution through a plate-fin heat exchanger is studied by using a computational fluid dynamics (CFD) code, FLUENT. The flow distribution through any heat exchanger affects its performance. In designing a heat exchanger, it is assumed that the fluid is uniformly distributed through the heat exchanger core. In practice, however, it is impossible to distribute fluid uniformly, because of an improper inlet configuration, imperfect design, and a complex heat transfer process. The CFD simulation of the flow distribution in the header of a conventional plate-fin heat exchanger is presented. It is found that the flow maldistribution is very serious in the y-direction of the header. A modified header is proposed and simulated using CFD. The modified header configuration has a more uniform flow distribution than the conventional header configuration. Hence, ...

2007-10-15

398

Augmentation of heat transfer in a tube with an oscillating thin plate. Shindohen sonyu ni yoru enkannai netsudentatsu sokushin  

Energy Technology Data Exchange (ETDEWEB)

An attempt is made to augment the heat transfer efficiency by means of inserting an oscillating thin plate into a tube of the shell and tube heat exchanger. However, the heat transfer augmenting mechanism has not been fully explained. To elucidate this heat transfer augmenting mechanism, an investigation was given on the heat transfer characteristics of a tube inlet at its preliminary run area when a double-hinged oscillating thin plate is inserted in the inlet. As a result of the experiment, the heat transfer augmentation in the tube as a result of inserting the double-hinged oscillating thin plate was found effective when the preliminary inlet run area is treated as the object. However, in comparison of the effect with the heat transfer in a fully developed turbulent region, it was {eta}- 1. The result thus obtained explains that no ...

1991-09-01

399

Kelvin-day function for climatic solar heating design  

Energy Technology Data Exchange (ETDEWEB)

A method of Kelvin-day function for climatic solar heating design is presented. The long term temperature distribution is used to find the solar fraction for building heating. A solar heating system is considered to provide heat needed up to an auxiliary heater cut-in temperature which is determined by both heat gain of solar heating system and overall heat loss coefficient of the building. The amount of auxiliary heat needed is calculated from a Kelvin-day value at this cut-in temperature. The cut-in temperature will change from different solar heating system designs, and the Kelvin-day value at this cut-in temperature will be varied. By using the numerical curve-fitting method, the Kelvin-day value at any temperature base can be expressed into a second order algebraic equation, thus, the whole data ...

1981-01-01

400

Comparison of central heating with district heating and small-scale cogeneration. Vergelijking van centrale verwarming met stadsverwarming en kleinschalige warmtekoppeling; Energiebesparing, emissies en financiele resultaten  

Energy Technology Data Exchange (ETDEWEB)

Three systems for the heat supply in the built environment have been compared for the costs, the energy consumption and emissions of CO{sub 2}, NO{sub x} and SO{sub 2}. The heating systems compared are based on central heating boilers, district heating systems in combination with combined steam and gas turbine cycles, and heating by means of several gas engines. From the results it appears that the boilers demand the lowest investments. The district heating systems are more expensive. Both heating systems, however, show considerable savings of energy (55 to 70%). The exploitation costs depend strongly on the fuel price scenarios used and the assumptions with regard to interest and inflation. The emissions of CO{sub 2} are also considerably lower for both combined heat and power generating systems. The use of gas engines ...

1991-07-01

401

A desiccant dehumidifier for electric vehicle heating  

Energy Technology Data Exchange (ETDEWEB)

Vehicle heating requires a substantial amount of energy. Engines in conventional cars produce enough waste heat to provide comfort heating and defogging/defrosting, even under very extreme conditions. Electric vehicles (EVs), however, generate little waste heat. Using battery energy for heating may consume a substantial fraction of the energy storage capacity, reducing the vehicle range, which is one of the most important parameters in determining EV acceptability. Water vapor generated by the vehicle passengers is in large part responsible for the high heating loads existing in vehicles. In cold climates, the generation of water vapor inside the car may result in water condensation on the windows, diminishing visibility. Two strategies are commonly used to avoid condensation on windows: windows are kept warm, and a large amount of ambient air is introduced in ...

1996-09-01

402

Thermal gradient humidification-dehumidification desalination system  

Energy Technology Data Exchange (ETDEWEB)

A solar energy desalination process utilizing solar radiation directly for the evaporation of salt water is described. Ambient air takes on water vapor as the air passes through an evaporative medium. It is then directed between a saline water-covered, solar absorbing surface and a solar collecting housing. The resulting heated and moisture-saturated air is cooled in a heat exchange means where condensation of fresh water occurs. Simultaneously, cool salt water is utilized as the cooling water in the heat exchange means, and takes on the heat of condensation given up by the condensing vapor. The heated salt water from the heat exchange means is partially directed over the solar absorbing surface, and at least a portion of it is also directed to wet the evaporative medium. Several optional sub-processes are described for operation of the system during periods of ...

1982-12-14

403

Thermal energy storage system with stearic acid as phase change material  

Energy Technology Data Exchange (ETDEWEB)

A simple tube-in-tube heat exchanger system for thermal energy storage employing stearic acid as PCM has been investigated. The performance and heat transfer characteristics of such a system were studied. Phase transition temperature range and times were measured and the speed of the phase transition front was computed. The melting front was found to move in the radial direction inward as well as in the axial direction from the top toward the bottom of the phase change material PCM tube. The speed of the melting front is enhanced by a convection heat transfer mechanism in the melted PCM. The heat transfer rate and, consequently, phase transition time can be altered by changing the water inlet temperature to the heat exchanger. In addition, a faster phase transition is realized by placing the heat exchanger in a horizontal position rather than a vertical one. ...

1994-10-01

404

The influence of wall deposits on heat transfer in combustion engines. Einfluss von Wandablagerungen auf den Waermeuebergang im Verbrennungsmotor  

Energy Technology Data Exchange (ETDEWEB)

The experimental survey about the heat transfer between the working fluid and the combustion chamber wall with a direct injection diesel engine has shown the production of a soot layer with increasing loads on the combustion chamber wall. Because the combustion process of methanol occurs without the formation of wall deposits, the same engine spark ignitioned with methanol at the same conditions has shown a higher heat transfer coefficient. Because the heat losses do not only depend on the heat transfer coefficient but also on the driving temperature difference between the working fluid and the combustion chamber wall, the methanol engine with corresponding process management showed lower heat losses than the diesel engine at nearly the same load. (orig./HW)

1994-04-01

405

Solar thermal aircraft  

Energy Technology Data Exchange (ETDEWEB)

A solar thermal powered aircraft powered by heat energy from the sun. A heat engine, such as a Stirling engine, is carried by the aircraft body for producing power for a propulsion mechanism, such as a propeller. The heat engine has a thermal battery in thermal contact with it so that heat is supplied from the thermal battery. A solar concentrator, such as reflective parabolic trough, is movably connected to an optically transparent section of the aircraft body for receiving and concentrating solar energy from within the aircraft. Concentrated solar energy is collected by a heat collection and transport conduit, and heat transported to the thermal battery. A solar tracker includes a heliostat for determining optimal alignment with the sun, and a drive motor actuating the solar concentrator into optimal alignment with the sun based on a determination by the ...

2007-09-18

406

Process for repairing a cryogenic heat exchanger  

International Nuclear Information System (INIS)

The patent describes a method for repairing leakage-causing cracks and fissures in a cryogenic heat exchanger. It comprises: reducing the interior pressure of the heat exchanger to a level which does not exceed the external pressure upon the hear exchanger while maintaining the temperature of the heat exchanger at a low level relative to the ambient external temperature; applying a curable liquid filler composition to the surface of the heat exchanger proximal the leakage site for seepage into the cracks and fissures located at the leakage. The composition upon a relatively short period of cure at low temperature forming a solid material which fills the cracks and fissures; curing the filler composition; and, applying a sealant composition to the surface of the heat exchanger at the filled leakage site. The sealant composition having long-term sealing performance under cyrogenic ...

1987-10-13

407

Numerical heat transfer studies of the fatty acids for different heat exchanger materials on the performance of a latent heat storage system  

Energy Technology Data Exchange (ETDEWEB)

Theoretical investigations of fatty acids as a phase change material (PCM) for energy storage system have been conducted in this study. The selected fatty acids were capric acid, lauric acid, myristic acid, palmitic acid and stearic acid. For the two-dimensional simulation model based on the enthalpy approach, calculations have been made for the melt fraction with conduction only. Glass, stainless steel, tin, aluminium mixed, aluminium and copper were used as heat exchanger materials in the numerical calculations. Theoretical results show that capric acid was found good compatibility with latent heat storage system. The large value of thermal conductivity of heat exchanger materials did not make significant contribution on the melt fraction. (author)

2005-11-01

408

Numerical and experimental investigation of shellside characteristics for RODbaffle heat exchanger  

Energy Technology Data Exchange (ETDEWEB)

RODbaffle heat exchanger is a kind of shell-and-tube heat exchanger with eminent performance. Because of the characteristics of tube bundle support structure, fluid flow on shellside is longitudinal and periodical, and fluid flow is of symmetry in landscape orientation. According to the fluid flow characteristics on shellside and ignoring the impact of inlet, outlet and shell wall, a periodic flow unit duct was taken as the simplified model of the shellside to perform numerical simulation by using CFD code, FLUENT. It was found that the both errors in magnitude of the main fluid velocities and heat transfer coefficients between results of simulation and that of experiment or correlations are less than 10%, and the errors of pressure drop between simulation and correlation are no more than 20%. The detailed characteristics and relation of fluid flow and heat transfer on shellside of the RODbaffle ...

2008-05-15

409

MINERGIE modules: heat pump - heat pump/solar - wood - wood/solar; Minergie-Module Waermepumpe - Waermepumpe/Solar - Holz - Holz/Solar  

Energy Technology Data Exchange (ETDEWEB)

This research report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that examined the feasibility of setting up 'MINERGIE' low-energy-consumption module standards for the production of heat in small residential buildings. The aims of the standards and the basic idea behind the MINERGIE-modules are discussed. The concepts of the modules for heat pumps and wood-fired heating systems and their combination with solar installations are examined, as are their areas of application. The requirements placed on the modules are listed. System concepts, including simple schematics for typical installations, are presented for wood-log, wood-chippings and pellets-fired systems as well as for ground-loop and air-water heat pump systems as well as their solar-aided counterparts. The results of cost-benefit analyses are presented and questions regarding system guarantee ...

2005-07-01

410

Human climatic comfort within enclosing walls with varying strengths of infrared radiation reflection  

Energy Technology Data Exchange (ETDEWEB)

An experiment lasting a number of hours was carried out with 6 men under standardised climate chamber conditions to find out to what extent wallpaper that reflects about 65-75% in the infra-red range by comparison with normal wallpaper that reflect only 3-5% of heat, has measurable positive effects on the thermoregulation of the human body and the human sensation of temperature. The measurements of skin temperature and heat flow intensity in the deeper areas of the body and the periphery, and metabolic heat conversion measurements (indirect calorimetry) confirm that infra-red reflection of the heat irradiated from the body lead to a measurable heat recovery on the body surface with a reduction of metabolic conversion. It was proved that it is possible to reduce the average room temperature by up to 4 K whilst maintaining the same degree of thermal comfort, which corresponds to a 20% ...

1985-06-01

411

Horizontal ground coupled heat pump: Thermal-economic modeling and optimization  

Energy Technology Data Exchange (ETDEWEB)

The modeling and optimizing processes of a Ground Coupled Heat Pump (GCHP) with closed Horizontal Ground Heat eXchanger (HGHX) are presented in this paper. After thermal modeling of GCHP including HGHX, the optimum design parameters of the system were estimated by minimizing a defined objective function (total of investment and operation costs) subject to a list of constraints. This procedure was performed applying Genetic Algorithm technique. For given heating/cooling loads and various climatic conditions, the optimum values of saturated temperature/pressure of condenser and evaporator as well as inlet and outlet temperatures of the water source in cooling and heating modes were predicted. Then, for our case study, the design parameters as well as the configuration of HGHX were obtained. Furthermore, the sensitivity analysis of change in the total annual cost of the system and optimum design parameters ...

2010-12-15

412

High thermal load receiving heat plate  

Energy Technology Data Exchange (ETDEWEB)

The present invention concerns a high thermal load heat receiving plate such as a divertor plate of a thermonuclear device. The high thermal load heat receiving plate of the present invention has a cooling performance capable of suppressing the temperature of an armour tile to less than a threshold value of the material against high thermal loads applied from plasmas. Spiral polygonal pipes are inserted in cooling pipes at a portion receiving high thermal loads in the high temperature load heat receiving plate of the present invention. Both ends of the polygonal pipes are sealed by lids. An area of the flow channel in the cooling pipes is thus reduced. Heat conductivity on the cooling surface of the cooling pipes is increased in the high thermal load heat receiving plate having such a structure. Accordingly, temperature elevation of the armour tile can be suppressed. (I.S.).

1993-09-28

413

Heat loss from an open cavity  

Energy Technology Data Exchange (ETDEWEB)

Cavity type receivers are used extensively in concentrating solar thermal energy collecting systems. The Solar Total Energy Project (STEP) in Shenandoah, Georgia is a large scale field test for the collection of solar thermal energy. The STEP experiment consists of a large field array of solar collectors used to supplement the process steam, cooling and other electrical power requirements of an adjacent knitwear manufacturing facility. The purpose of the tests, conducted for this study, was to isolate and quantify the radiative, conductive, and convective components of total heat loss, and to determine the effects of operating temperature, receiver angle, and aperture size on cavity heat loss. An analytical model for radiative heat loss was developed and compared with two other methods used to determine radiative heat loss. A proposed convective heat loss correlation, including ...

1995-12-01

414

Heat Transfer Characteristics of Tubular Thermal Reactor  

International Nuclear Information System (INIS)

Heat transfer augmentation based on the process intensification concept in heat exchangers and thermal reactors has received much attention in recent years, mainly due to energy efficiency and environmental considerations. The concept consists of the development of novel apparatuses and techniques that, compared to those commonly used today, are expected to bring dramatic improvements in manufacturing and processing, substantially decreasing equipment size, energy consumption, and ultimately resulting in cheaper, sustainable technologies. The objective of this paper was to investigate the heat transfer characteristics of tubular thermal reactor using static mixing technology. Glycerin and water were used as the test fluids and water was used as the heating source. The results for heat transfer rate were strongly influenced by tube geometry and flow conditions.

415

Fundamental study of heat transfer and flow situation around a spacer (in the case of a cylindrical rod as a spacer)  

International Nuclear Information System (INIS)

This paper describes the heat transfer augmentation and the flow situation around a single spacer (a cylindrical rod) on the heated surface of a parallel plate duct in order to examine basically the effects of the spacer in the fuel elements of a high temperature gas-cooled reactor. The ends of the cylindrical rod contact the upper and lower planes. A thermosensitive liquid crystal film is used to indicate the effective area for the heat transfer. The mean Nusselt number, which is estimated within the optional distance from the spacer to the downstream direction, peaks at a dimensionless distance of X/D = 1-3, and after that decreases gradually with the flow direction. The manner in which heat transfer corresponds to the flow situation is also examined. The horseshoe vortex, produced around the spacer, affects the wake and contributes to the increase of the local heat transfer. ...

1988-01-01

416

Full-scale model of cooling and heating system for JT-60 vacuum vessel  

Science.gov (United States)

A full-scale model of a rigid sectorial ring and a set of bellows which was covered with a temperature control layer and a coolant supply equipment was constructed to verify the adequacy of the heating and cooling system designed for JT-60. To cool and heat it effectively and to decrease the temperature differences among the various parts in the vacuum vessel, heater units and cooling pipes were located on the surface of the ring. The temperature control layer is to heat the vessel to 500/degree/sub //C within 70 hours and to maintain it at the temperature for 48 hours for simulating the state of bakeout. Subsequently the vessel is cooled down within about the same time as in heating. Prior to the series of tests, numerical analyses were performed to predict the cooling and heating efficiencies on the model and to examine the method of the temperature regulation.

1981-01-01

417

Condensation heat transfer in a steam-water stratified flow  

Energy Technology Data Exchange (ETDEWEB)

Fundamental phenomena of condensation heat transfer at a steam-water interface have been studied related to the thermo-hydrodynamics of the emergency core cooling system for light water reactors. In this study temperature fluctuations near the interface and in the liquid phase were measured using fine thermocouples for a saturated steam-subcooled water co-current stratified two-phase flow in a nearly horizontal rectangular channel, and heat transfer coefficients were determined experimentally. The values of the condensation heat transfer coefficients in this experiment are from 6 to 40 kW/m{sup 2}K. In the regions of high Reynolds numbers, as the steam Reynolds numbers become larger, the average interfacial heat transfer coefficients tend to increase. The corelations of Nusselt numbers were obtained from the heat transfer data. (author)

1999-07-01

418

Condensation heat transfer in a steam-water stratified flow  

International Nuclear Information System (INIS)

Fundamental phenomena of condensation heat transfer at a steam-water interface have been studied related to the thermo-hydrodynamics of the emergency core cooling system for light water reactors. In this study temperature fluctuations near the interface and in the liquid phase were measured using fine thermocouples for a saturated steam-subcooled water co-current stratified two-phase flow in a nearly horizontal rectangular channel, and heat transfer coefficients were determined experimentally. The values of the condensation heat transfer coefficients in this experiment are from 6 to 40 kW/m"2K. In the regions of high Reynolds numbers, as the steam Reynolds numbers become larger, the average interfacial heat transfer coefficients tend to increase. The corelations of Nusselt numbers were obtained from the heat transfer data. (author)

1999-04-19

419

Comparison of stomach contents and condition of two catfish species living at ambient temperatures and in a heated discharge  

International Nuclear Information System (INIS)

The lower condition factors for two catfish species in water heated by effluents from APCo's Glen Lyn, Virginia plant as compared to control areas probably is not due to lack of food as evidenced by macroinvertebrate sampling and the fact that only 4.3 percent of the catfish stomachs were empty. Results suggested that young-of-the-year channel catfish were nonselectively eating food organisms present at both control and heated stations. The difference between stomach contents of flatheat catfish from the heated site and fauna available at that site indicated that fish were either moving out of the heated area to feed or were selectively feeding on organisms (particularly mayflies) which were in the substrate or drifted into the heated area. Stomach contents of the two species and distribution and abundance of the macroinvertebrate benthos community are detailed.

420

C-E critical heat flux. Critical heat flux correlation for C-E fuel assemblies with standard spacer grids. Part 1. Uniform axial power distribution  

International Nuclear Information System (INIS)

The report presents the results of experimental studies conducted to provide a description of the conditions which lead to the occurrence of critical heat flux (CHF), in Combustion Engineering (C-E) fuel assemblies using the C-E standard spacer grid. A CHF correlation is presented which is based on CHF data obtained in tests with electrically heated rod bundles representative of the C-E 14 x 14 and 16 x 16 array fuel assemblies. The results reported are for a uniform axial heat flux distribution. The experiments were conducted in the Medium Pressure Heat Transfer Flow Loop at the Chemical Engineering Research Laboratories at Columbia University.

421

Boiling heat transfer of subcooled water in a horizontal rectangular channel. Observation of MEB and MEB generation; Kukeikan ryuronai no subcool futto netsu dentatsu. Kiho bisaika futto no kansatsu to hassei joken  

Energy Technology Data Exchange (ETDEWEB)

Forced convection boiling of subcooled water was performed in a horizontal rectangular channel with heated surface on the bottom. The experiment was conducted for heating surfaces, 10 mm, 20 mm and 40mm in length. Microbubble Emission Boiling, MEB, was observed in subcooled transition boiling and easy to be generated for the shorter heating surfaces. In higher flow velocity of subcooled water, MEB was generated at even lower subcooling. Stormy MEB was observed at both the higher subcooling and the higher flow velocity of water. In the stormy MEB, the heat flux rose up rapidly above CHF (Critical Heat Flux) with larger acoustic noise and vibration. (author)

1999-09-25

422

Approximate solutions to the Stefan problem with internal heat generation  

Energy Technology Data Exchange (ETDEWEB)

Using a quasi-static approach valid for Stefan numbers less than one, we derive approximate equations governing the movement of a phase change front for materials which generate internal heat. These models are applied for both constant surface temperature and constant surface heat flux boundary conditions, in cylindrical, spherical, plane wall and semi-infinite geometries. Exact solutions with the constant surface temperature condition are obtained for the steady-state solidification thickness using the cylinder, sphere, and plane wall geometries which show that the thickness depends on the inverse square root of the internal heat generation. Under constant surface heat flux conditions, closed form equations can be obtained for the three geometries. In the case of the semi-infinite wall, we show that for constant temperature and constant heat flux out of the wall conditions, the ...

2008-05-15

423

Application of Combined Enhanced Techniques for Design of Highly Efficient Air Heat Transfer Surface  

British Library Electronic Table of Contents (United Kingdom)

In order to reduce the size and cost of heat exchangers, an air-side wavy fin-and-tube heat transfer surface with three-row tubes needs to be replaced by two-row tubes with some appropriate enhancing techniques. The major purpose of the present paper is to search for such new structure by numerical simulation. First, longitudinal vortex generators of Delta-winglet type are tried. The influence of number and of arrangement of the winglets on the performance of the heat transfer surface is studied in detail. The numerical results show that the fin with two winglets aligned spanwise in the front and rear of each tube (Fin W6) has higher heat transfer capability than other enhanced structures with vortex generators, but it still unable to meet the heat transfer requirement. Then a combination ...

2012-01-01

424

Analysis of WITCH/LINER experiments on heat transfer between gas-agitated steel melt and vertical wall  

Energy Technology Data Exchange (ETDEWEB)

The analysis for the WITCH/LINER experiments was performed to investigate the heat transfer characteristics between the gas-agitated steel melt and the vertical surface. The applicability of heat transfer correlations for a gas-agitated fluid system was examined through the numerical analysis of the one-dimensional heat conduction taking into account the crust formation due to the solidification of the steel melt. The heat transfer correlation developed by Konsetov was modified for the application to fluids with low Prandtl number. The constant in the modified correlation was empirically found mainly through the comparison between the analysis and the experiments under conditions that a churn-turbulent two-phase flow regime was anticipated to form. The modified Konsetov correlation could predict the heat transfer characteristics observed through the experiments in an acceptable ...

1999-10-01

425

A fundamental study of the heat transfer and flow situation around a spacer  

International Nuclear Information System (INIS)

This paper describes the heat transfer augmentation and flow situation around a single spacer (a circular cylinder) on a heated surface in a parallel plate duct in order to examine basically the effects of the spacer in the fuel elements of a High Temperature Gas-cooled Reactor. A thermosensitive liquid crystal film was used to clarify the effective region of the heat transfer. The mean Nusselt number, which was estimated within arbitrary distance from the spacer to the downstream direction, took a peak at the dimensionless distance X/D = 1 #approx# 3, and after that decreased gradually with flow direction. How heat transfer corresponds to the flow situation is also examined. The horseshoe vortex, produced around the spacer, affects the wake and contributes to the increase of the local heat transfer. (author).

1986-01-01

426

Review of passive heat transfer augmentation techniques  

Energy Technology Data Exchange (ETDEWEB)

Heat transfer augmentation techniques (passive, active or a combination of passive and active methods) are commonly used in areas such as process industries, heating and cooling in evaporators, thermal power plants, air- conditioning equipment, refrigerators, radiators for space vehicles, automobiles, etc. Passive techniques, where inserts are used in the flow passage to augment the heat transfer rate, are advantageous compared with active techniques, because the insert manufacturing process is simple and these techniques can be easily employed in an existing heat exchanger. In design of compact heat exchangers, passive techniques of heat transfer augmentation can play an important role if a proper passive insert configuration can be selected according to the heat exchanger working condition (both flow and heat transfer ...

2004-12-01

427

Recovery of Water from Boiler Flue Gas  

Energy Technology Data Exchange (ETDEWEB)

This project dealt with use of condensing heat exchangers to recover water vapor from flue gas at coal-fired power plants. Pilot-scale heat transfer tests were performed to determine the relationship between flue gas moisture concentration, heat exchanger design and operating conditions, and water vapor condensation rate. The tests also determined the extent to which the condensation processes for water and acid vapors in flue gas can be made to occur separately in different heat transfer sections. The results showed flue gas water vapor condensed in the low temperature region of the heat exchanger system, with water capture efficiencies depending strongly on flue gas moisture content, cooling water inlet temperature, heat exchanger design and flue gas and cooling water flow rates. Sulfuric acid vapor condensed in both the high temperature and low temperature ...

2008-09-30

428

Mechanisms of heat transfer augmentatiton around the stagnation point of an impinging air jet laden with solid particles. Report 2. ; Effects of thermal properties of laden particles and heat transfer surface on heat transfer augmentation due to the unsteady heat conduction. Koki niso shototsu funryu no yodomiten kinbo ni okeru dennetsu sokushin kiko. 2. ; Sesshoku netsudendo ni yoru dennetsu sokushin ni taisuru ryushi to dennetsumen no netsubusseichi no eikyo to sono hyoka  

Energy Technology Data Exchange (ETDEWEB)

The heat transfer augmentation effect by the unsteady heat conduction between the particles and heat transfer surface is one of the main factors, causing the heat transfer augmentation around the stagnation point in the gas-solid two-phase impinging jet flow. By separating and evaluating that effect, material influence on it was studied of particles and heat transfer surface, together with change by the jet flow condition. That effect enlarged with enlarging in heat capacity, multiplied by the heat conduction coefficient, of both the particles and heat transfer surface, and if both of them were constant in material combination, was dominated by the contact frequency of particles per unit time. Therefore in case of lading solid particles, equal in weight, that effect enlarges with diminishing in particle diameter. Such a ...

1991-05-25

429

Fiscal 2000 project of inviting proposals for international joint research - invitation for international proposal (Energy conservation No.2). Achievement report on international joint study on popularization promotion of geothermal heat pump-assisted environmentally compatible heating system for Changchun City, China; 2000 nendo kokusai kyodo kenkyu teian kobo jigyo - kokusai teian kobo (Shoe No.2). Chinetsu heat pump ni yoru Chugoku Changchun shi kankyo tekigogata danbo system no fukyu sokushin ni kansuru kokusai kyodo kenkyu seika hokokusho  

Energy Technology Data Exchange (ETDEWEB)

A geothermal heat pump-assisted heating system is introduced into Changchun City and a survey is conducted to determine if the system may be popularized in this extremely cold region located in the northeastern part of China. In concrete terms, the hot water that circulates through the office building of Changchun Ground Heat Development Co., Ltd., is switched to hot water prepared by a geothermal heat pump. The test continued from December 2000 to March 2001. It is then concluded that heating by geothermal heat pumps will be fully serviceable to Changchun City. Implemented are (1) the shift from the coal fired boiler system to a geothermal heat pump system comprising 16 subterranean heat exchangers for the heating of the office building which is approximately 1000 m{sup 2} large, (2) long-term ...

2001-03-01

430

FY1998 research report on the basic research on geothermal district heating in Kamchatka, Russia; 1998 nendo Roshia Renpo Kamchatka shu ni okeru chinetsu riyo ni yoru chiiki danbo ni kansuru kiso chosa hokokusho  

Energy Technology Data Exchange (ETDEWEB)

Petropavlovsk-Kamchatky (P-K) city in Kamchatka, Russia is operating hot-water district heating using heavy oil boilers and waste hot water of thermal power plants as heat sources. Feasibility study was made on district heating using natural geothermal hot water and/or geothermal heat pump systems as heat sources of hot water supply for reduction of greenhouse effect gas emission. Among 3 areas including geothermal hot water, use of hot water in K area was impossible because of lower temperature and less spring water. Use of hot water in P and UP areas was impossible as primary hot water because of temperature drop to 64 degrees C during hot water supply toward P-K city. The building heating operation test was carried out using the geothermal heat pump system installed in a newly drilled heat exchange well of 100m deep. ...

1999-05-01

431

X-radiation effects on muscle cell membrane electrical parameters  

International Nuclear Information System (INIS)

Early effects of 100 Kilorads of X-rays on muscle cell membrane properties have been measured in sartorius muscles from Leptodactylus ocellatus. Threshold strength for rectangular current pulses increased 10% after irradiation, and action potential propagation velocity decreased 10%. Passive membrane parameters were calculated from potential responses to sub-threshold current pulses, assuming conventional cable theory. Specific membrane conductance increased to 18% after irradiation, membrane capacitance increased 14%, and length constant decreased 10% but membrane time constant was unchanged. Cell diameter decreased 5%, and resting membrane potential decreased 8%. Membrane parameters during an action potential were also evaluated by the phase-plane and current-voltage plot techniques. Irradiation significantly decreased the action potential amplitude, the excitation potential, and the maximum rates of rise and fall of membrane potential. Increases were observed in ...

432

Substance Flow Analyses of Organic Pollutants in Stockholm  

International Nuclear Information System (INIS)

This paper summarizes substance flow analyses for four organic substances in the City of Stockholm, Sweden: diethylhexyl phthalate (DEHP), alkylphenolethoxylates (APEO), polybrominated diphenylethers (PBDE) and chlorinated paraffins (CP). The results indicate that the stocks of APEO, PBDE and CP all are approximately 200-250 tonnes, whereas the DEHP stock is two orders of magnitude larger. Emissions can be linked to imported consumer goods such as electronics (PBDE) and textiles (APEO), and to construction materials (DEHP, CP). For several of the substances considerable amounts remain in the technosphere for a long time, even after use of the substance in new products has been eliminated. For example, the use of DEHP as plasticizer for PVC plastics in cables and floorings has more or less been phased-out, but still these applications make up a stock of some 20,000 tonnes (85% of the total DEHP stock in Stockholm) and emit 28 tonnes of DEHP annually (93% of overall ...

2008-12-01

433

Splice assembly tool and method of splicing  

Energy Technology Data Exchange (ETDEWEB)

A splice assembly tool for assembling component parts of an electrical conductor while producing a splice connection between electrical cables therewith, comprises a first structural member adaptable for supporting force applying means thereon, said force applying means enabling a rotary force applied manually thereto to be converted to a longitudinal force for subsequent application against a first component part of said electrical connection, a second structural member adaptable for engaging a second component part in a manner to assist said first structural member in assembling the component parts relative to one another and transmission means for conveying said longitudinal force between said first and said second structural members, said first and said second structural members being coupled to one another by said transmission means, wherein at least one of said component parts comprises a tubular elastomeric sleeve and said force applying means provides a ...

1980-01-01

434

Retractable barrier strip  

Energy Technology Data Exchange (ETDEWEB)

A portable barrier strip having retractable tire-puncture spikes for puncturing a vehicle tire. The tire-puncture spikes have an armed position for puncturing a tire and a retracted position for not puncturing a tire. The strip comprises a plurality of barrier blocks having the tire-puncture spikes removably disposed in a shaft that is rotatably disposed in each barrier block. The plurality of barrier blocks hare hingedly interconnected by complementary hinges integrally formed into the side of each barrier block which allow the strip to be rolled for easy storage and retrieval, but which prevent irregular or back bending of the strip. The shafts of adjacent barrier blocks are pivotally interconnected via a double hinged universal joint to accommodate irregularities in a roadway surface and to transmit torsional motion of the shaft from block to block. A single flexshaft cable is connected to the shaft of an end block to allow a user to selectively cause the shafts ...

2002-01-01

435

Research and development on probe inserting method into steam generator helically coiled tubes for in-service inspection  

International Nuclear Information System (INIS)

Helically coiled tubes of steam generators (SG) in FBR are boundaries between sodium and water/steam. Therefore, to assure the integrity of tubes, it is necessary to inspect the tubes nondestructively for in service or after a sodium-water reaction accident. In order to make it possible to conduct in-service inspection of SG tubes, we have studied on eddy current probes and probe inserting methods. As for the probe inserting method, IHI designed a fluid driving type which consists of a model probe and signal cable with float balls and driven by air pressure force. Presented in this paper is the authors' report, which describes the fluid driving type as an effective method to insert an eddy current probe into helically coiled tubes. The outline of the test results is as follows: 1. It was possible to insert the probe into 65 meter length helically coiled tubes. 2. We could detected, as anticipated, a defect (outer circumferential wall thinning defect, 20% depth) on ...

1979-01-01

436

Reasons for the power failure in Auckland, New Zealand; Ursachen der Stromunterbrechung in Auckland, Neuseeland  

Energy Technology Data Exchange (ETDEWEB)

On February 20th 1998 Auckland, the biggest city of New Zealand, was nearly paralyzed by an extended power failure. On this day the last of four cables supplying the central business district failed and caused a five weeks lasting blackout. This failure has caused costs of 128.3 Mio NZ Dollar for the affected utility Mercury Energy Ltd. The official ministerial inquiry was published on July 21st 1998 and reproaches the utility in an unusual clear manner. (orig.) [Deutsch] Am 20. Februar 1998 wurde Auckland, die groesste Stadt Neuseelands, von einer folgenschweren Unterbrechung der Stromversorgung nahezu lahmgelegt. An diesem Tag fiel das letzte von vier 110-kV-Kabeln zur Versorgung des Innenstadtbereiches aus und verursachte damit einen 5 Wochen dauernden Stromausfall. Diese Versorgungsunterbrechung hat bisher Kosten in Hoehe von 128,3 Mio NZ Dollar (rd. 115,5 Mio DM) fuer den oertlichen Stromversorger Mercury Energy Limited verursacht. Der am 21. Juli 1998 ...

1998-11-30

437

Radiological safety aspects associated with the handling, storage and disposal of self power neutron detectors in TAPS - 3 and 4  

International Nuclear Information System (INIS)

At Tarapur Atomic Power Station 3 and 4, 540 MWe Pressurised Heavy Water Reactors, core being large in size requires a continuous in core monitoring for local flux disturbances. Nearly 200 Self Powered Neutron Detectors (SPNDs) of the Straight Individually Replaceable (SIR) type are distributed in the reactor core. For purpose of reactor regulation and protection, cobalt SPNDs that have a prompt response for changes in power is used for in-core flux mapping, vanadium SPNDs that provide accurate measure of neutron flux, even though having slow response is used In core SPNDs are placed in Vertical Flux Units (VFU) and Horizontal Flux Units (HFUs). These SPNDs were to be replaced at regular intervals to meet the design intent. Cobalt SPNDs have dose rates of the order of 1000 Gy/h and the Mineral Insulated (MI) cables of Vanadium SPNDs have dose rates of the order of 100 Gy/h. So far 3 Cobalt SPNDs were removed from HFUs and are being stored in lead shielding inside ...

2006-11-13

438

Open vs Closed Access Femtocells in the Uplink  

CERN Document Server

Femtocells are assuming an increasingly important role in the coverage and capacity of cellular networks. In contrast to existing cellular systems, femtocells are end-user deployed and controlled, randomly located, and rely on third party backhaul (e.g. DSL or cable modem). Femtocells can be configured to be either open access or closed access. Open access allows an arbitrary nearby cellular user to use the femtocell, whereas closed access restricts the use of the femtocell to users explicitly approved by the owner. Seemingly, the network operator would prefer an open access deployment since this provides an inexpensive way to expand their network capabilities, whereas the femtocell owner would prefer closed access, in order to keep the femtocell's capacity and backhaul to himself. We show mathematically and through simulations that the reality is more complicated for both parties, and that the best approach depends heavily on whether the multiple access scheme is ...

2010-01-01

439

On-line analysis of chemical composition using an FT-Raman spectrometer in the near-ir  

Science.gov (United States)

Newly commercialized Fourier transform Raman spectroscopic instrumentation provides a simpler alternative for vibrational spectroscopic analysis. Instrument vendors currently design for laboratory use, but there are many potential process applications of these stable, easy to use instruments. Raman spectroscopy is highly suited to analysis of aqueous samples. Near infrared excitation minimized fluorescence interference and allows for remote operation via fiber optic probes. The Department of Energy has funded research at the Measurement and Control Center to establish the utility of this method for on-line composition analysis in distillation columns. Laboratory evaluation and instrument employs an air-cooled laser and a thermoelectrically cooled detector. The device is mounted on a three by foot cart for convenient location in control rooms. Current fiber optic extension cables allow for analysis in a cell thirty five meters from the instrument. Application of the ...

1992-01-01

440

Limitations of traveling wave relaying for overhead EHV transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Limitations of traveling wave relaying schemes for protection of overhead extra-high voltage transmission lines are investigated. A method of analysis of traveling wave phenomena for three phase transmission lines is developed in which the interdependent phase voltages and currents are decoupled into their modal counterparts, which are approximately independent. A time domain digital simulation program is used to solve the modal transmission line equations to obtain the fault induced traveling waves detected at the relay location. The frequency dependence of the aerial modes is ignored but their losses are included. A lumped element analysis method, originally developed for transient analysis of lossy coaxial cables, is adapted here to obtain approximate solution for the fault induced traveling waves of the ground mode. Excellent agreement is found between the results obtained by this method and frequency domain methods. This time-domain method offers more ...

1986-01-01

441

Lead recycling; Namari no recycle  

Energy Technology Data Exchange (ETDEWEB)

In Japan, lead has been widely used for gasoline additives, inorganic chemicals such as pigment, lead pipes/plates, and coating materials of cable. Because of the steady increase in car population and the mounting of environmental concern, lead consumption ratio for lead-acid batteries is tending to increase gradually up to 70% with decreasing the consumption for gasoline additives. This paper describes the recycling of lead-acid batteries in Japan. Since the latter half of FY 1994, the battery manufacturing industry started the new lead recycling system. The recycling ratio of the used lead-acid batteries became 90% in 1996 from 84% in 1994. In near future, it can reach to 95%, the recycling ratio in some European countries. The primary smelting occupies 53%, and the secondary smelting occupies 47%. For the conventional method by secondary smelting makers, reduction smelting and copper removing of lead electrodes are conducted, and lead is recycled as tertiary ...

1997-12-25

442

Integration of turbo-generator modules in digital transient network analyzer  

Science.gov (United States)

The behavior of a small power system consisting of two interconnected generators is simulated in real-time by a prototype Digital Transient Network Analyzer (TNA). The prototype Digital TNA consists of two Computational Modules and one I/O Module. The Modules communicate with each other through ribbon cables. Each Computational Module simulates one Turbo-Generator, its Transformer, its Governor, Exciter, and Power System Stabilizer Systems. The numerical integration is shared by two TMS320C30 DSPs at a step-size of 100 microseconds in real-time. The I/O module post-processes the state variables and presents selected information for analog display. The paper presents oscillograms from a test program which includes symmetry checks and behavioral checks against well known waveforms of hunting oscillations, synchronization out-of-phase torques, and subsynchronous resonance phenomena. The success of the Digital TNA depends on: (a) the theoretical method of Decoupled ...

1994-05-01

443

Electroforming of metals: state-of-the-art assessment. Final report  

Energy Technology Data Exchange (ETDEWEB)

An assessment of the state-of-the-art of electromagnetic and electrohydraulic forming of metal parts has been conducted. Electromagnetic forming (EMF) shapes parts by a force resulting from a high-density magnetic field. The electrohydraulic forming (EHF) process differs in that the force is applied to parts from a shock wave emanating from a point within a fluid medium. Both processes are used to form relatively thin-section hollow or flat products. This survey has found that, of the two electrotechnologies, the electromagnetic forming process is expected to be used increasingly in a broad range of industries, particularly for automotive, aircraft, and electrical-cable components. In contrast, the level of applications for the electrohydraulic forming method is expected to remain essentially unchanged over the near- and long-term period. This is because its use is restricted to relatively unusual part shapes in industries that do not require large unit quantities. ...

1986-07-01

444

ESR/Alanine dosimetry on Wolsung Unit 1  

Energy Technology Data Exchange (ETDEWEB)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level in few points of ...

2007-07-01

445

ESR/Alanine dosimetry on Wolsung Unit 1  

International Nuclear Information System (INIS)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level in few points of ...

2007-05-10

446

DYMAC communications system  

Energy Technology Data Exchange (ETDEWEB)

The DYMAC Communications System is part of a nuclear safeguards system called DYMAC - short for DYnamic Materials ACcountability - that gathers accountability information at the Los Alamos Scientific Laboratory (LASL) Plutonium Processing Facility. The communications system handles transmissions between data-entry terminals and nondestructive assay (NDA) instruments located in the facility, and a computer located in an adjacent building. System design emphasizes reliability rather than high speed to ensure the integrity of data transmissions. This manual is directed toward the person responsible for maintaining the DYMAC Communication System. It describes the components that make up the communications network, explains how they operate, and gives detailed information about all of the connections. Many of the system components are commercially available; some have been modified at LASL for DYMAC purposes; others were designed and fabricated at LASL. This manual provides circuit diagrams ...

1980-01-01

447

Thermal energy storage system using stearic acid as a phase change material  

Energy Technology Data Exchange (ETDEWEB)

The thermal performance and phase change stability of stearic acid as a latent heat energy storage material has been studied experimentally. The thermal performance and heat transfer characteristics of the stearic acid were tested and compared with other studies given in the literature. In the present study, parameters such as transition times, temperature range and propagation of the solid-liquid interface as well as the effect of heat flow rate on the phase change stability of stearic acid as a phase change material (PCM) were studied. The experimental results showed that the melting stability of the PCM is better in the radial direction than in the axial direction. The variation in the melting and solidification parameters of the PCM with the change of inlet water temperature is also studied. We observed that while the heat exchanger tube is in the horizontal position, the PCM has more effective and ...

2001-07-01

448

The determination of hemoglobin and myoglogin residues as a parameter for testing heat exposure in back bacon.  

UK PubMed Central (United Kingdom)

The use of an extraction of the heme pigments hemoglobin and myoglobin as a test for the heat exposure of back bacon was investigated by treating back bacon at varying temperatures of 50-70 degrees...Full Text Available

1976-07-01

449

The Mechanism and the Magnitude of Flow Boiling Augmentation in Tubes with Discrete Surface Roughness Elements (III).  

Science.gov (United States)

Related to other research on the effectiveness of flow boiling heat transfer augmentation using various types of turbulators this investigation comprises a definitive study of the effect of large discrete roughness elements on heat transfer over the entir...

1972-01-01

450

Stagnation region heat transfer: The influence of turbulence parameters, Reynolds number and body shape  

Science.gov (United States)

The effect of velocity gradient on stagnation region heat transfer augmentation by free stream turbulence was investigated. Heat transfer was measured in the stagnation region of four models with elliptical leading edges with ratios of major to minor axes of 1:1, 1.5:1, 2.25:1, and 3:1. Four geometrically similar, square bar, square mesh, biplane grids were used to generate free stream turbulence with different intensities and length. Heat transfer measurements were made for the following ranges of parameters: Reynolds number, based on leading edge diameter, 37,000 to 228,000; dimensionless leading edge velocity gradient, 1.20 to 1.80; turbulence intensity, 1.1 to 15.9%; and length scale to leading edge diameter ratio, 0.05 to 0.30. Stagnation point heat transfer augmentation by free stream turbulence can be predicted using a modified version of a previously developed correlation for a circular leading ...

1994-02-01

451

Reinvestigation of the effect of carbenoxolone on the induction of heat shock proteins  

UK PubMed Central (United Kingdom)

Carbenoxolone (CBX) is a semisynthetic derivative of the licorice root substance glycyrrhizinic acid and has been previously reported to induce only heat shock protein 70 [Hsp70, HSPA1A (the systematic...Full Text Available

2009-09-01

452

Performance evaluation of a vortex generator heat transfer surface and comparison with different high performance surfaces  

International Nuclear Information System (INIS)

A comparative assessment of five different heat transfer configurations for operation in compact heat exchangers is presented. The configurations under consideration are four standaed heat exchanger surfaces - two plain fin, an offset strip and a louvered fin geometry - and one surface with so called vortex generators for heat transfer augmentation. In the case of the standard surfaces, the basic performance characteristics in the form of heat transfer and friction data versus the Reynolds number have been taken from published experimental results. In the case of the vortex generator surface, the performance characteristics have been derived from a numerical prediction of the flow and temperature field in a closely spaced parallel plate channel with vortex generators in the form of delta wings mounted on the channel walls. In comparison to the plain fin surfaces with a rectangular ...

1993-01-01

453

Performance characteristics of a natural circulation cooling/latent heat storage system  

Energy Technology Data Exchange (ETDEWEB)

A cooling system was developed which could be used even in such areas where the maximum and minimum temperatures of a day might differ widely. The system features in that a latent heat storage unit is connected to the natural circulation cooling unit consisting of 2 heat exchangers where condensed gas (refrigerant) which performs gas-liquid change has been sealed, enabling to cool objects night and day without the requirement for any power source. Electronic equipment was installed in an insulated shelter. Lauric acid and refrigerant R-22 were used as the latent heat storage medium and the heat transport medium respectively. Natural convection heat transfer performance of the outside surfaces of the condenser and the evaporator and the transient behavior of the system during the melting and solidification periods of the latent heat storage medium were tested. As ...

1987-09-25

454

Laboratory simulation of a deep-ocean in-situ heat-transfer experiment  

Energy Technology Data Exchange (ETDEWEB)

The Subseabed Disposal Program has recently completed a 30-day, 0.286-scale laboratory simulation of an In Situ Heat Transfer Experiment (ISHTE), scheduled for eventual deployment in the deep ocean 600 nautical miles north of Hawaii. 10 figures.

1982-01-01

455

Laboratory simulation of a deep-ocean in-situ heat-transfer experiment  

International Nuclear Information System (INIS)

The Subseabed Disposal Program has recently completed a 30-day, 0.286-scale laboratory simulation of an In Situ Heat Transfer Experiment (ISHTE), scheduled for eventual deployment in the deep ocean 600 nautical miles north of Hawaii. 10 figures.

1982-09-22

456

Incidence and Diversity of Potentially Highly Heat-Resistant Spores Isolated at Dairy Farms  

UK PubMed Central (United Kingdom)

The presence of highly heat-resistant spores of Bacillus sporothermodurans in ultrahigh-temperature or sterilized consumer milk has emerged as an important item in the dairy industry....Full Text Available

2005-03-01

457

Improvement of structure and mechanical properties of cast titanium alloys using rapid heat treatment  

Energy Technology Data Exchange (ETDEWEB)

The possibility of rapid heat treatment (RHT) application to titanium castings has been studied. It was shown that such treatment provides a significant improvement of intragrain structure and mechanical properties of cast ({alpha}+{beta})-titanium alloys. ((orig.))

1995-01-01

458

Heats (enthalpies) of formation of coals and the thermodynamic evaluation of the coal formation process  

British Library Electronic Table of Contents (United Kingdom)

An approach to the calculation of the quantity of heat consumed in the process of coal formation is presented. The variability of this parameter in a coalification series is analyzed using coals from the Kuznetsk and Tunguska Basins as an example.

2011-01-01

459

Heat transfer augmentation in a heat exchanger tube using a baffle  

International Nuclear Information System (INIS)

Heat transfer enhancement in a heat exchanger tube by installing a baffle is reported. The effect of baffle size and orientation on the heat transfer enhancement was studied in detail. Three different baffle arrangements were considered. The results show that for the vertical baffle, an increase in the baffle height causes a substantial increase in the Nusselt number but the pressure loss is also very significant. For the inclined baffles, the results show that the Nusselt number enhancement is almost independent of the baffle inclination angle, with the maximum and average Nusselt number 120% and 70% higher than that for the case of no baffle, respectively. For a given baffle geometry, the Nusselt number enhancement is increased by more than a factor of two as the Reynolds number decreased from 20,000 to 5000. Simulations were conducted by introducing another baffle to enhance heat transfer. The ...

2007-04-01

460

Heat transfer augmentation in 3D internally finned and microfinned helical tube  

Energy Technology Data Exchange (ETDEWEB)

Experiments are performed to investigate the single-phase flow and flow-boiling heat transfer augmentation in 3D internally finned and micro-finned helical tubes. The tests for single-phase flow heat transfer augmentation are carried out in helical tubes with a curvature of 0.0663 and a length of 1.15 m, and the examined range of the Reynolds number varies from 1000 to 8500. Within the applied range of Reynolds number, compared with the smooth helical tube, the average heat transfer augmentation ratio for the two finned tubes is 71% and 103%, but associated with a flow resistance increase of 90% and 140%, respectively. A higher fin height gives a higher heat transfer rate and a larger friction flow resistance. The tests for flow-boiling heat transfer are carried out in 3D internally micro-finned helical tube with a curvature of 0.0605 and a length of 0.668 m. Compared with that in ...

2005-05-01

461

Heat storage material  

Science.gov (United States)

The heat storage material consists of a mixture of oleic and stearic acids in which stearic acid is present to the extent of 30 percent to 90 percent by weight. In addition to this binary system, the invention is also directed to a ternary system in which diphenyl ether is present along with the stearic and oleic acids.

1955-12-06

462

Heat recovery heralds fuel economy breakthrough  

Energy Technology Data Exchange (ETDEWEB)

In the interests of fuel economy in motor vehicles, this article discusses the importance of waste heat recovery and then goes on the explore options such as hybrid electric cars, thermal engines with low loss platforms, pure electric vehicles and fuel cell vehicles. (UK)

1995-10-01

463

Heat loss due to incomplete combustion of agricultural residues  

Energy Technology Data Exchange (ETDEWEB)

The methodology of constructing Nomographs for easy determination of heat loss due to incomplete combustion for a particular fuel has been presented in this article. The authors have worked out the Nomograph for jute stick and paddy straw.

1984-07-01

464

Heat Cycle Reserch Experimental Program report, FY-84  

Energy Technology Data Exchange (ETDEWEB)

The Heat Cycle Research Facility (HCRF) is an experimental binary-cycle facility used to investigate different concepts and/or components for generating electrical power from a geothermal resource. This report briefly desc

1984-09-01

465

Guidelines on exchangers  

Energy Technology Data Exchange (ETDEWEB)

Experience has shown that a list of tips provides designers and engineers with an effective guide in their areas of duties and concern. This list contains new and rare information on heat exchangers and heat recovery systems. The information presented can be used effectively with personal computers and pocket calculators and also conveniently translated into computer programs and nomographs.

1985-08-01

466

Geothermal heat-pump systems are competing today against conventional fuels  

Energy Technology Data Exchange (ETDEWEB)

The alternative to the use of deeper wells through temperature amplification of the geothermal resource by electric heat pumps is explored. Systems in Ephrata, Washington and Chamberlain, South Dakota are explored. (MHR)

1982-12-01

467

Gas Turbine Blade Heat Transfer Augmentation by Impingement of Air Jets Having Various Configurations.  

Science.gov (United States)

An experimental investigation of heat transfer characteristics for various configurations of air jets impinging on the leading edge inner surface of a gas turbine blade wall is presented. Three configurations were investigated, namely a slot jet, a round ...

1970-01-01

468

Fundamental study of heat transfer augmentation by smooth turbulence surface promotors  

International Nuclear Information System (INIS)

In the utilization of the thermal energy by ocean temperature difference and factory waste heat, the high performance heating surfaces in pipes from which scale can be removed are required. As the method of removing scale, the method using sponge balls seems most suitable, but for applying this method, as the form of the protrusions attached to the inner surfaces of pipes, smooth circular are form is desirable. The promotion of heat transfer with the rows of circular arc protrusions like this is strongly related to the mode of flow and such structure as separation, recirculation flow, readhesion and turbulent energy generation. In this study, as the basic research to optimize the heating surface with the rows of smooth protrusions, the flow characteristics and the heat transfer characteristics including the turbulent structure of the wake of protrusions were experimentally ...

1985-01-01

469

Experimental investigations on the characteristics of melting processes of stearic acid in an annulus and its thermal conductivity enhancement by fins  

Energy Technology Data Exchange (ETDEWEB)

An experimental rig was set up to study the performance of a thermal storage unit using stearic acid as the heat storage medium. The unit mainly consists of an electrical heating rod and an outer tube, and the space between is an annulus that is filled with stearic acid. The thermal performance of the unit is measured, and the heat transfer characteristics of the melting processes of stearic acid are studied under different heat flux conditions to determine the influence of heat flux on the melting processes. A new type of fin is designed and fixed to the electrical heating rod to enhance the thermal response of the stearic acid. The experimental results show that the fin can improve the heat transfer of the melting process of the thermal storage unit greatly. The equivalent thermal conductivity of the PCM can be augmented by a factor up to ...

2005-04-01

470

Experimental investigations on the characteristics of melting processes of stearic acid in an annulus and its thermal conductivity enhancement by fins  

Energy Technology Data Exchange (ETDEWEB)

An experimental rig was set up to study the performance of a thermal storage unit using stearic acid as the heat storage medium. The unit mainly consists of an electrical heating rod and an outer tube, and the space between is an annulus that is filled with stearic acid. The thermal performance of the unit is measured, and the heat transfer characteristics of the melting processes of stearic acid are studied under different heat flux conditions to determine the influence of heat flux on the melting processes. A new type of fin is designed and fixed to the electrical heating rod to enhance the thermal response of the stearic acid. The experimental results show that the fin can improve the heat transfer of the melting process of the thermal storage unit greatly. The equivalent thermal conductivity of the PCM can be augmented by a factor up to ...

2005-04-01

471

Experimental Study of a Method of Mechanical Augmentation of Convective Heat Transfer Coefficients in Air.  

Science.gov (United States)

Scraped-surface heat transfer augmentation is proposed as a possible technique for use in improved air-cooling designs. Although it has been in common use with liquids, the technique has apparently never been used with gases. An experimental investigation...

1974-01-01

472

Energy and exergy efficiencies of ground-source heat pump systems (GSHPs) for residential applications. Paper no. IGEC-1-067  

International Nuclear Information System (INIS)

Ground-source heat pump systems (GSHPSs), also referred to as geothermal heat pump systems (GHPSs), have been widely used in residential and commercial buildings for years due to their outstanding energy utilization efficiencies. In this study, an energy and exergy modeling of solar assisted ground-source heat pump systems for residential applications is presented for system analysis and performance evaluation. In this regard, the performance of a solar assisted ground-source heat pump heating system, installed in Solar Energy Institute of Ege University, Izmir, Turkey, is evaluated based on the actual operational data to show how energy and exergy efficiencies values change with the system. The average heating coefficient of performances (as energy efficiencies) of the solar assisted ground-source heat pump (GSHP) unit and the overall ...

2005-06-12

473

Effects of the Temperature Lag on Thermoluminescence Analysis with Hoogenstraaten's Heating Rate Method  

International Nuclear Information System (INIS)

Hoogenstraaten's heating rate method has generally been considered as a reliable method for determining thermoluminescence trapping parameters of first order glow peaks. However, experience has shown that in some cases the deviation between the heating rate method and glow curve fitting method can be quite significant (considering only the linear part of the heating rate plot, of course). In this study it is shown that one of the main reasons for this deviation can be a systematic increase of a temperature lag between the measured and real temperature of the sample with increasing heating rate. It appears that this systematic increase of the temperature lag affects the method in the range of low heating rates (linear part of the heating rates plots) more than has been previously realised. The effect of the temperature lag on Hoogenstraaten's ...

1998-07-05

474

Effects of the Temperature Lag on Thermoluminescence Analysis with Hoogenstraaten's Heating Rate Method  

Energy Technology Data Exchange (ETDEWEB)

Hoogenstraaten's heating rate method has generally been considered as a reliable method for determining thermoluminescence trapping parameters of first order glow peaks. However, experience has shown that in some cases the deviation between the heating rate method and glow curve fitting method can be quite significant (considering only the linear part of the heating rate plot, of course). In this study it is shown that one of the main reasons for this deviation can be a systematic increase of a temperature lag between the measured and real temperature of the sample with increasing heating rate. It appears that this systematic increase of the temperature lag affects the method in the range of low heating rates (linear part of the heating rates plots) more than has been previously realised. The effect of the temperature lag on Hoogenstraaten's ...

1999-07-01

475

Effect of heat transfer augmentation by square rod array in impinging air jet system(heat transfer characteristic of potential core region)  

Energy Technology Data Exchange (ETDEWEB)

This research has been proceeded over the potential core region (H/B=2) of two-dimensional impinging air jet system, in which square rods(width of 6 mm) has been set up in front of heating surface in order to increase heat transfer. The objective of this research was to investigate the characteristics of heat transfer and air flow, in cases of the clearance from rods to heating surface (C = 1, 2, 4, 6 mm) and the pitch between each rods(P = 30, 40, 50 mm) changed. And this research compared the above with the experimentation without rods. As result, heat transfer performance was best under the condition of C = 1 mm, in case clearance changed, and there was no serious difference in the effect of heat transfer augmentation in the case of pitch of rods changed. (author) 11 refs. 12 figs.

1995-07-01

476

Effect of Heat Treatment on Some Mechanical Properties of Laminated Window Profiles Manufactured Using Two Types of Adhesives  

UK PubMed Central (United Kingdom)

The mechanical properties of laminated window profiles manufactured using two types of adhesives were determined. The objective of this study is to evaluate the effects of heat treatment on some mechanical...Full Text Available

477

Development of a coal fired pulse combustor for residential space heating. Technical progress report, October--December 1986  

Energy Technology Data Exchange (ETDEWEB)

This progress report presents a detailed description of the background, technology and application, and Statement of Work for the development of a coal-fired pulse combustor for residential space heating.

1986-12-31

478

A heating tube  

Energy Technology Data Exchange (ETDEWEB)

Hollow needles made of an electrically conducting material are attached by hinges in the openings of the perforated end of an insert in order to intensify heat and mass transfer. The free sections of the needles are placed outside the insert, and a wick is placed on the wall of the frame in the condensation area. The wick overlaps the inlet openings of the insert.

1980-09-23

479

Vortex generator induced heat transfer augmentation past a rib in a heated duct air flow  

Energy Technology Data Exchange (ETDEWEB)

The present investigation represents the initial phase of a comprehensive experimental program designed to study the potential for increasing the heat transfer per unit pressure drop in a ribbed duct by positioning vortex generators at key locations in the flow. In particular, the present investigation consists of a rib positioned at the inlet to a rectangular test section with uniform heating at its bottom wall. Local and average Nusselt number results are obtained for a circular rod positioned either immediately above or just downstream of the rib.

1992-02-01

480

Ultrasonic enhancement of heat transfer on narrow surface  

Energy Technology Data Exchange (ETDEWEB)

Ultrasonic enhancement of heat transfer on a narrow surface was measured by changing the width of the surface from 8 to 0.1 mm. Ultrasonic power of 600 W with a frequency of 40 kHz was used. Heat transfer on the narrow surface without ultrasonic vibration was correlated by the experimental equation for a thin wire. The cavitation intensity was measured by the cavitation erosion loss of an aluminum foil of 15 [mu]m thickness. The effects of acoustic streaming and cavitation were separated by this measurement. Heat transfer by acoustic streaming was predicted through forced convection. Enhancement by cavitation was explained by the turbulence thermal conductivity of the microjets.

1994-06-01

482

Residential vertical geothermal heat pump system models: Calibration to data  

Energy Technology Data Exchange (ETDEWEB)

A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was tuned to better match the measured data from the site. These tuned models were then interconnected to form the system model. The system model was then exercised in order to demonstrate its capabilities.

1997-12-31

483

Residential Vertical Geothermal Heat Pump System Models: Calibration to Data:  

Energy Technology Data Exchange (ETDEWEB)

A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was 'tuned' to better match the measured data from the site. These tuned models were then interconnect to form the system model. The system model was then exercised in order to demonatrate its capabilities.

1997-06-01

484

On vortices heating biological excitable media  

International Nuclear Information System (INIS)

An extension of the Hodgkin-Huxley mathematical model for the propagation of nerve signal which takes into account dynamical heat transfer in biological tissue is derived and fine tuned with existing experimental data. The medium is heated by Joule's effect associated with action potential propagation, leading to characteristic thermal patterns in association with spiral and scroll waves. The introduction of heat transfer-necessary on physical grounds-provides a novel way to directly observe the movement, regular or chaotic, of the tip of spiral waves in numerical simulations and possibly in experiments regarding different biological excitable media.

2009-11-30

485

New crafts of a master builder  

Energy Technology Data Exchange (ETDEWEB)

Innovative new ideas for the construction of homes are described. A thermal energy storage system fireplace and a geothermal heat pump for homes are described.

1983-11-01

486

Neutron star evolution with internal heating  

Energy Technology Data Exchange (ETDEWEB)

The thermal evolution predicted by current models of the superfluid-crust interaction is noted to differ substantially from the thermal evolution predicted by models without internal heating as well as previous models of heating. Heating rates approaching the maximum predicted by current models enhance the photon luminosity of the star in the neutrino cooling era, and dramatically alter the thermal evolution in the photon cooling era. Standard cooling models are consistent with current pulsar temperature estimates and upper limits, except those for the Vela pulsar, which are lower than predicted. 77 refs.

1989-11-01

487

National Earth Comfort Program, Geothermal Heat Pump Market Mobilization and Technology Demonstration  

Energy Technology Data Exchange (ETDEWEB)

Late 1994, the Geothermal Heat Pump Consortium (GHPC) was launched as a non-profit collaborative effort between the United States Department of Energy, US electric utilities and the GeoExchange (geothermal heat pump) industry to make ''geothermal heat pumps'' a significant component of the HVAC industry and avoid 1.5 million metric tons of carbon equivalent per year. The goal was to create a self-sustainable GeoExchange market. This report offers a summary of some of the lessons learned and an overview of some of the programs major accomplishments.

2001-04-30

490

Kinetics of the direct electric heating of a stationary bed of activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

Direct electric heating by passing an electrical current directly through a bed of adsorbent may prove to be an efficient means of regenerating activated charcoal in continuous and batch adsorption processes. Obvious advantages of this type of regeneration are its almost complete lack of inertia, which makes it possible to reduce the number and dimensions of the adsorbers, and its highly efficient use of energy due to the small number of steps in the conversion of the energy, as well as the reduction of heat losses involved in warming the structure and making up for losses to the surroundings. The authors consider the kinetics of direct electric heating of a stationary bed of activated charcoal not containing adsorbed substances.

1987-08-20

491

Improved formability of ultra high strength steels through local heat treatment  

Energy Technology Data Exchange (ETDEWEB)

In this paper it is described how a martensitic steel sheet with tensile strength of 1400 MPa is heat treated locally. The sheet is then formed in the heat treated regions in a way that would be impossible with the untreated material. Mechanical properties and forming limit diagrams of the heat treated material are determined and the forming operations are simulated, which shows that the method can be used by designers. Although the method has been known for decades, it remains to be industrialised and the work presented here is to be seen as a contribution to this development. (orig.)

2005-07-01

492

Heating and cooling  

Energy Technology Data Exchange (ETDEWEB)

Why pay for energy when there`s a free stockpile of it right under your feet? With the help of a geothermal heat pump system, one can extract that energy from the ground and put it to good use, lowering heating and cooling costs. From private homes to public schools and fast-food restaurants, an increasing number of establishments are turning to geothermal heat pump systems for space conditioning. Experts say 1998 is already proving to be the best year yet for the technology, and they foresee an even more promising future. Some examples of geothermal energy use are given.

1998-05-01

493

Heat transfer augmentation in inverted annular film boiling  

International Nuclear Information System (INIS)

(Jun 1982). United States Edelman, Z. Chambre, P. Eilas, E. Naot, D. Technion,

1982-06-11

494

Flue gas desulfurization. Rauchgasentschwefelung  

Energy Technology Data Exchange (ETDEWEB)

Low-dust flue gases can be washed efficiently of SO/sub 2/, and the flue gas heat can be utilized. The residual heat fraction still required by the process is characterized by a temperature of 15/sup 0/K above the temperature of the purified flue gas. Marketable crystalline ammonium sulfate is produced. The high efficiency and low heat consumption are achieved by combining all process stages in a single, fully integrated cycle process free of heat and materials losses. The process is characterized by high efficiency, low investment and operating costs, recovery of thermal energy, and production of an ammonium sulfate fertilizer.

1983-04-07

495

Flooded Underground Coal Mines: A Significant Source of Inexpensive Geothermal Energy  

Energy Technology Data Exchange (ETDEWEB)

Many mining regions in the United States contain extensive areas of flooded underground mines. The water within these mines represents a significant and widespread opportunity for extracting low-grade, geothermal energy. Based on current energy prices, geothermal heat pump systems using mine water could reduce the annual costs for heating to over 70 percent compared to conventional heating methods (natural gas or heating oil). These same systems could reduce annual cooling costs by up to 50 percent over standard air conditioning in many areas of the country. (Formatted full-text version is released by permission of publisher)

2007-04-01

498

An investigation of turbulent convection heat transfer performance in spiral spring coil inserted tubes  

International Nuclear Information System (INIS)

This paper presents the results of the experimental investigation on heat transfer and fluid friction characteristics of a class of spiral spring coil used as a tube side forced convection heat transfer augmentation devices. Based on a lot of experimental data, the heat transfer correlation and fluid friction correlation revised by temperature were reached in terms of linear regression. At the same time, proper criteria were used to evaluate the economic performance of the spiral spring inserted tube according to the demand of practical application and some probing analysis were made.

1996-01-01

499

A mathematical model for simulating shallow solar ponds for treatment of industrial wastewater  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a mathematical model to analyze the solar evaporation in a shallow pond in steady state, when the inlet flow rate, concentration, surface area and solar radiation are given. The simultaneous heat and mass transfer mechanisms are considered for quantifying the amount of evaporated water to the atmosphere and the actual absorbed heat by wastewater is calculated to obtain the bottom temperature of water pond. The heat losses to air by radiation and convection mechanisms are considered and the heat transmission across the water film is evaluated by the forced convection mechanism. 6 refs., 5 figs., 1 tab.

1996-12-31