International Nuclear Information System (INIS)
An earlier representation of the radial distribution of dose about the path of a heavy ion in liquid water is modified and extended to include silicon, lithium fluoride, and sodium iodide. 6 refs., 5 figs., 1 tab.
1989-09-01
Radial distribution of dose and cross-sections for the inactivation of dry enzymes and viruses
International Nuclear Information System (INIS)
A new semi-empirical algorithm for the radial distribution of dose is compared with available data. The algorithm is used to calculate the inactivation cross section for dry enzymes and viruses using an extended target model of a 1-hit detector. Agreement with data is at about the 15% level, approximating the precision of the data itself. (author).
1985-05-01
Radial dose distribution of 6.0 MeV/n #alpha#-particle in water
International Nuclear Information System (INIS)
For the study of radiation biology and its application to radiotherapy, the double differential cross section of electron emission from water vapor induced by 6.0 MeV alpha particle beam is measured. The energy spectra of electrons ranging 7- 10000 eV are detected by the electrostatic analyzer and micro channel plate. The measurements are made at angles between 20 and 160 degrees. With use of this data set, the radial dose distribution in water is calculated by using KURBUC code. It is the Monte Carlo type code of the electron transport process, where the track of the electron is simulated through each individual interactions including elastic scattering, ionization cross section and total excitation cross section in case that electrons with certain energy are put in the liquid-density water. In order to understand the effect of radiation when the particle flux is injected in the human body like radiotherapy using ...
2003-08-17
AAPM TG-43 formalism for brachytherapy dose calculation of a 137Cs tube source
International Nuclear Information System (INIS)
We present a development of the use of the AAPM TG-43 dose formalism applied to "1"3"7Cs gynecological implant sources. The geometry factor, radial dose function, and anisotropy function of a "1"3"7Cs source modeled after the Nuclear Associates 67-809 series stainless steel jacketed tube source were derived following the AAPM TG-43 formalism. The dose rate distribution through the center of the source using the AAPM TG-43 dose formalism is calculated and compared with the calculations obtained using the Sievert summation and Monte Carlo simulation. The three methods resulted in an agreement within less than 5%, or an isodose rate line agreement within 2 mm. We demonstrate that the AAPM TG-43 formalism can be applied to "1"3"7Cs linear sources and is capable of serving as a "1"3"7Cs dose calculation algorithm that can be used for treatment ...
2004-04-01
International Nuclear Information System (INIS)
The efficient use of the fuel is one of the objectives in the assemblies design of type BWR. The present tendency in the assemblies design of type BWR is through a radial distribution of enrichments. The present work has like object showing the because of this decision, for what a comparison of the neutronic performance of two fuel cells with the same enrichment average but one of them with radial distribution of enrichment and the other with a single enrichment equal to the average. The cells were analyzed with the CASMO-4 code and the obtained results of the behavior of the neutron flow and the power sustain the because of the radial distribution of enrichments. (Author)
2008-07-06
Examination of graphitization products of coal by using radial distribution function method
Energy Technology Data Exchange (ETDEWEB)
The radial distribution function (RDF) derived from wide angle X-ray diffraction patterns gives additional information about the spatial distribution of atoms. Their radial distances and relative average coordination numbers can be calculated using appropriate mathematical procedures. 7 refs.
1991-01-01
Monte Carlo calculations using the codes PENELOPE and GEANT4 have been performed to characterize the dosimetric parameters of the new 20 mm long catheter based $^{32}$P beta source manufactured by Guidant Corporation. The dose distribution along the transverse axis and the two dimensional dose rate table have been calculated. Also, the dose rate at the reference point, the radial dose function and the anisotropy function were evaluated according to the adapted TG-60 formalism for cylindrical sources. PENELOPE and GEANT4 codes were first verified against previous results corresponding to the old 27 mm Guidant $^{32}$P beta source. The dose rate at the reference point for the unsheathed 27 mm source in water was calculated to be $0.215 \\pm 0.001$ cGy s$^{-1}$ mCi$^{-1}$, for PENELOPE, and $0.2312 \\pm 0.0008$ cGy s$^{-1}$ mCi$^{-1}$, for ...
2003-01-01
International Nuclear Information System (INIS)
German (15 Jun 1974). Switzerland Kocian, P. Ecole Polytechnique Federale,
1974-06-01
FFTF reactor characterization program
International Nuclear Information System (INIS)
Preparations are under way for the initial startup and testing of the Fast Flux Test Facility (FFTF). The FFTF Reactor Characterization Program is that part of the startup test plan that deals with the determination of the neutron, gamma ray and thermal hydraulic characteristics of the reactor. This program encompasses measurements and calculations of: neutron spectra, flux and fluence; gamma-ray spectra, dose and heating; fission rate distributions; capture rate distributions; other reaction rates of interest; fission product yields; and thermal hydraulic data. Measurements of these parameters will be made in the reactor core and reflectors, will extend vertically downward to the vicinity of the core support structure and upward to the top of the sodium pool, and will extend radially outward to include in-vessel fuel storage locations and the cavity between the reactor vessel and the concrete wall.
Hyperfine anomaly measurements in francium isotopes and the radial distribution of neutrons
International Nuclear Information System (INIS)
We have performed precision measurements in a magneto-optical trap of the 7P1/2 hyperfine structure of the isotopes 209-210Fr. The ratio of these hyperfine constants to the previously measured 7S1/2 ground state values reveals a significant hyperfine anomaly. This anomaly results from the different radial dependence of the electron density in the two atomic levels. The measurements are sensitive to changes in the radial distribution of the neutron magnetism.
1999-09-01
International Nuclear Information System (INIS)
For the Convolution, Superposition and Monte Carlo methods, energy spectrum data is an essential parameter. Especially, by using Monte Carlo method, if the adequate properties of electrons are set, complex energy spectrum data can be calculated by simple input. However, adjustment of the property of electrons incident on the target of linear accelerator is time-consuming procedure. To cover the difference of many accelerators, it is important how we obtain accurate energy spectrum by simple methods. Especially, the total accuracy of dose calculation depends on the agreement of measured and calculated percentage depth dose (PDD) and off-axis ratio (OAR). Thus, a simple method for the determination of the simulation parameters was considered. To reduce the adjustment procedure, we selected values of important three parameters, which were the mean energy of the input electron beam, the energy distribution of the input electron ...
2005-06-01
Radial distribution functions of amorphous silicon
Energy Technology Data Exchange (ETDEWEB)
Substantial changes in the radial distribution function of amorphous Si films have been observed in neutron-diffraction studies. The spectra indicate changes in short-range order associated with an approx.11% modification in the bond-angle distribution width. The results allow the first direct comparison of structural and vibrational Raman probes of variations in local order in thin-film amorphous solids. Good agreement is obtained between the measured bond-angle variation and that based on Raman estimates.
1989-03-15
Optimal selection of capacitors for radial distribution systems using a genetic algorithm
Energy Technology Data Exchange (ETDEWEB)
In this paper, a new design methodology for determining the size, location, type and number of capacitors to be placed on a radial distribution system is presented. The objective is to minimize the peak power losses and the energy losses in the distribution system considering the capacitor cost. A sensitivity analysis based method is used to select the candidate locations for the capacitors. A new optimization method using a Genetic Algorithm is proposed to determine the optimal selection of capacitors. Test results have been presented along with the discussion of the algorithm.
1994-08-01
Loop frame of reference based three-phase power flow for unbalanced radial distribution systems
Energy Technology Data Exchange (ETDEWEB)
This paper introduces a novel three-phase power flow approach for unbalanced radial distribution systems. The proposed approach is developed based on the loop frame of reference, rather than the traditional bus frame of reference. On the basis of the loop frame of reference, a simple direct iterative method in impedance form is applied. Basic graph theory and injection current technique are also applied in the proposed approach. The clear theoretical foundation and the simple topology of the radial distribution network make the proposed method efficient and reliable. To demonstrate the better convergence performance and the efficiency of the proposed approach, four three-phase IEEE test feeders are used for comparisons. The test results show that the proposed method has robust convergence characteristics and high performance, especially for large-scale radial ...
2010-07-15
First derivative of the hard-sphere radial distribution function at contact
Energy Technology Data Exchange (ETDEWEB)
Molecular dynamics simulations have been carried out of the radial distribution function of the hard sphere fluid for a range of densities in the equilibrium fluid and just into the metastable region. The first derivative of the hard-sphere radial distribution function at contact was computed and its density dependence fitted to a simple analytic form. Comparisons were made with semi-empirical formulae from the literature, and of these the formula proposed by Tao et al (1992 Phys. Rev. A 46 8007) was found to be in best agreement with the simulation data, although it slightly underestimates the derivative at the higher packing fractions in excess of about 0.45. Close to contact, within a few per cent of the particle diameter, the radial distribution function can be represented well by a second order polynomial. An exponential function, which has some useful ...
2006-08-16
Radial velocities, dynamics of stars and nebulosities with GAIA and VLT-GIRAFFE
This document is divided in two parts. The first part deals with the radial velocities (RV) distributions for B-type stars and nebulosities observed with the VLT-GIRAFFE in the Large and Small Magellanic Clouds towards the open clusters NGC2004 and NGC330. Thanks to the resolution of GIRAFFE spectra, we found that the RV distribution for the nebulosities in the LMC is bi-modal. This bi-modality can be interpreted, in term of dynamics, by the expansion of the LMC4 superbubble. The second part deals with the GAIA space mission and the determination of the radial velocities by using Radial Velocity Spectrometer (RVS) spectra. The methods to determine the radial velocities are presented as well as preliminary results on simulated RVS spectra.
2008-01-01
International Nuclear Information System (INIS)
The Monte-Carlo method and experimental methods were used to determine the neutron fluxes in the irradiation channels of the Ghana Research Reactor -1. The MCNP5 code was used for this purpose to simulate the radial and axial distribution of the neutron fluxes within all the ten irradiation channels. The results obtained were compared with the experimental results. After the MCNP simulation and experimental procedure, it was observed that axially, the fluxes rise to a peak before falling and then finally leveling out. Axially and radially, it was also observed that the fluxes in the centre of the channels were lower than on the sides. Radially, the fluxes dip in the centre while it increases steadily towards the sides of the channels. The results have shown that there are flux variations within the irradiation channels both axially and radially. (au)
2009-01-01
Some features of the atomic radial-distribution functions of metal glasses
Energy Technology Data Exchange (ETDEWEB)
This paper attempts to explain the peculiarities of the radial-distribution function of metal glasses without involving ideas of the amorphous structure. On a computer, the radial atomic density for a spherical eutectic single crystal of the composition Fe/sub 84/C/sub 16/ of radius 15 A formed by alternating small crystals of e-Fe and Fe/sub 3/C of cubic form with the edge of the cube ca 10 A. For the sake of clarity, the diagram of such a quasisingle crystal is shown and has been given a cubic boundary. The change in the relationship between the heights of the subpeaks of the second maximum of the radial distribution function of atoms in the Fe-B glasses with a change in the concentration of boron can be explained by the change in the space group of the Fe/sub 3/B metastable boride which is formed in this system.
1986-09-01
Method of describing dose distributions in computer design of teleradiotherapy
International Nuclear Information System (INIS)
Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.
Radial distribution of bonded fission gas in mixed carbide fuel pins
International Nuclear Information System (INIS)
The fission gas xenon bonded in bubbles, in pore, and in the lattice of mixed carbide fuels is measured by electron-probe microanalysis. Radial xenon distribution and release curves are determined and are calibrated by gas chromatography of the bonded fission gas and by burnup analysis in the respective pin sections of the irradiation experiments FR2 6A and 6C, Mol 11/K 2, and DFR 330/1. The results are correlated to the microstructure of the fuel, bonding medium, temperature, and burnup. (Auth.).
1979-01-01
Radial distribution functions of liquid Na and Cs
International Nuclear Information System (INIS)
Radial distribution functions of liquid sodium and caesium at 100"0C have been calculated by the method of molecular dynamics with interionic pair potentials derived from Heine-Abarenkov-Shaw type model potential. The results were found to be in good agreement with recent experimental data. (Auth.).
1978-01-01
Radial distribution function and second virial coefficient for interacting bosons
International Nuclear Information System (INIS)
The radial distribution function and the second virial coefficient of interacting bosons have been studied. The second virial coefficient has been deduced theoretically and is in good agreement with experimental values. The third virial coefficient has been calculated from the experimental values of the pressure. (Auth.).
1976-01-01
Radial distribution of superthermal electrons measured with ECE (abstract)
International Nuclear Information System (INIS)
To aid in the study of lower hybrid current drive as a means of current profile control, the radial profile and velocity distribution of the fast current-carrying electrons and their time evolution must be known. As part of the recent effort to understand this fast electron transport, a diagnostic has been installed on PBX-M to measure the electron cyclotron emission from the fast electrons. An oblique horizontal view of upshifted cyclotron emission in the midplane can give radial as well as velocity space information about the fast electrons. Emission in X mode frequencies refracted by the right-hand cutoff is radially localized. The observed emission at a specific frequency comes only from the radial region r_t_u_r_n=#0. Emission measured by this new diagnostic has been found to be radially localized as predicted. It is also expected that localized moments of ...
0854-01-01
A novel approach for measuring the radial distribution of charge in a heavy ion track
International Nuclear Information System (INIS)
The energy deposited by the passage of a single, energetic, heavy-ion through a semiconductor produces dense electron-hole (eh) pair concentrations near the ion trajectory. The size, shape, and charge density of an ion track represent critical parameters for many models of single event phenomena. The authors describe the design and uses of possible semiconductor test structures for measuring the initial radial distribution of charge and subsequent charge transport in a high energy, heavy-ion track. Numerical simulations show how the test structure can resolve different radial distributions of charge within an ion track. The test structure simulations also show the importance of accurately representing ion track structure in single event effects simulations.
1994-07-18
International Nuclear Information System (INIS)
For a given linac design, the dosimetric characteristics of a photon beam are determined uniquely by the energy and radial distributions of the electron beam striking the x-ray target. However, in the usual commissioning of a beam from measured data, a large number of variables can be independently tuned, making it difficult to derive a unique and self-consistent beam model. For example, the measured dosimetric penumbra in water may be attributed in various proportions to the lateral secondary electron range, the focal spot size and the transmission through the tips of a non-divergent collimator; the head-scatter component in the tails of the transverse profiles may not be easy to resolve from phantom scatter and head leakage; and the head-scatter tails corresponding to a certain extra-focal source model may not agree self-consistently with in-air output factors measured on the central axis. To reduce the number of adjustable variables in beam ...
2005-09-07
International Nuclear Information System (INIS)
XAFS data of metallic glass Al_0_._9_1La_0_._0_9 and a crystalline phase Al_1_1La_3 formed by annealing of the glass were measured at the La L_3 edge at T=12 K and analyzed using the radial distribution function method. The shortest La-Al distance appeared to be distinctively smaller within the glass than in the crystal. This difference decreases the disparity in size of La and Al in the alloy, allowing their mixing in the glassy state. ((orig.)).
1994-09-02
A peculiar distribution of radial velocities of faint radio-galaxies with 13.0<=msub(corr)<=15.5
International Nuclear Information System (INIS)
A sample of 41 radio-galaxies with 13.0<=msub(corr)<=15.5 has been analyzed to test the angular redshift anisotropy discovered on Sc I galaxies by Rubin, Rubin and Ford (1973). The sample does not present their anisotropy but contains an even more curious distribution of radial velocities which suggests that the Rubin-Ford effect results from an anomalous redshift of light when it travels through clusters of galaxies. (Auth.).
Dose planning and dose delivery in radiation therapy
International Nuclear Information System (INIS)
A method has been developed for calibration of CT-numbers to volumetric electron density distributions using tissue substitutes of known elemental composition and experimentally determined electron density. This information have been used in a dose calculation method based on photon and electron interaction processes. The method utilizes a convolution integral between the photon fluence matrix and dose distribution kernels. Inhomogeneous media are accounted for using the theorems of Fano and O'Connor for scaling dose distribution kernels in proportion to electron density. For clinical application of a calculated dose plan, a method for prediction of accelerator output have been developed. The methods gives the number of monitor units that has to be given to obtain a certain absorbed dose to a point inside an irregular, ...
2008-08-01
On the Impact of Longitudinal Breathing Motion Randomness for Tomotherapy Delivery
UK PubMed Central (United Kingdom)
The purpose of this study is to explain the unplanned longitudinal dose modulations that appear in helical tomotherapy (HT) dose distributions in the presence of irregular patient breathing....Full Text Available
2008-09-21
On the accuracy and effectiveness of dose reconstruction for tomotherapy
International Nuclear Information System (INIS)
Dose reconstruction is a process that re-creates the treatment-time dose deposited in a patient provided there is knowledge of the delivered energy fluence and the patient's anatomy at the time of treatment. A method for reconstructing dose is presented. The process starts with delivery verification, in which the incident energy fluence from a treatment is computed using the exit detector signal and a transfer matrix to convert the detector signal to energy fluence. With the verified energy fluence and a CT image of the patient in the treatment position, the treatment-time dose distribution is computed using any model-based algorithm such as convolution/superposition or Monte Carlo. The accuracy of dose reconstruction and the ability of the process to reveal delivery errors are presented. Regarding accuracy, a reconstructed dose ...
2001-04-01
International Nuclear Information System (INIS)
The DNA double-strand break (DSB) damage response induced by high energy charged particles on lung fibroblast cells embedded in a 3-dimensional (3-D) collagen tissue equivalents was investigated using antibodies to the DNA damage response proteins gamma-histone 2AX (#gamma#-H2AX) and phosphorylated DNA-PKcs (p-DNA-PKcs). 3-D tissue equivalents were irradiated in positions across the linear distribution of the Bragg curve profiles of 307.7 MeV/nucleon, 556.9 MeV/nucleon, or 967.0 MeV/nucleon "5"6Fe ions at a dose of 0.30 Gy. Patterns of discrete DNA damage streaks across nuclei or saturated nuclear damage were observed, with saturated nuclear damage being more predominant as samples were positioned closer to the physical Bragg peak. Quantification of the DNA damage signal intensities at each distance for each of the examined energies revealed a biological Bragg curve profile with a pattern of DNA damage intensity similar to the physical Bragg ...
2010-03-01
UK PubMed Central (United Kingdom)
Voxel-based prescriptions of deliberately non-uniform dose distributions based on molecular imaging, so-called dose painting or theragnostic radiation therapy, require specification of a transformation...Full Text Available
2009-03-21
Absorbed dose and dose equivalent depth distributions for protons with energies from 2 to 600 MeV
Energy Technology Data Exchange (ETDEWEB)
Depth dose distributions for protons in the energy range from 2 to 600 MeV have been calculated by Monte Carlo and analytical methods. The dependence on energy of Maximum Dose Equivalent (MDE), quality factor and isotropic factor recommended for practical use are presented. The problems connected with regulation of maximum permissible proton fluxes are discussed. (author).
1989-01-01
Radial distribution functions. 5
International Nuclear Information System (INIS)
The noncrystalline compounds MoS_3, WS_3 and MoSe_3 were studied by X-ray diffraction. From the diffuse intensities radial distribution functions were computed and interpreted in terms of pair distribution functions. The substances are built up by microcrystallites which contain three metal atoms and are bridged statistically to each another. The shortest metal chalcogen distances d(MoS) approximately d(WS) = 2.40 +- 0.05 A and d(MoSe) = 2.50 +- 0.05 A are significantly longer than in MS- or MSe compounds with a d"0 configuration of the metal respectively and metal-metal distances within the microcrystallites are less than 3 A. (author).
1977-01-01
A new reconfiguration scheme for voltage stability enhancement of radial distribution systems
International Nuclear Information System (INIS)
Network reconfiguration is an operation problem, which entails altering the topological structure of the distribution feeders by rearranging the status of switches in order to obtain an optimal configuration in order to minimise the system losses. This paper presents a new reconfiguration algorithm that enhances voltage stability and improves the voltage profile besides minimising losses without incurring any additional cost for installation of capacitors, tap changing transformers and related switching equipment in the distribution system. Test results on a 69 node distribution system reveal the superiority of this algorithm.
2009-09-01
Dose verification using a pelvic phantom in high dose rate (HDR) brachytherapy
Energy Technology Data Exchange (ETDEWEB)
High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions ...
2003-07-01
International Nuclear Information System (INIS)
The mass distribution of the Sombrero Galaxy, NGC 4594, is calculated in order to investigate the suspicion that the rotational velocity of the galactic gas does not measure the circular velocity in the galaxy. It is shown that the H II rotation velocities are much less than circular in the central 35 arcsec of the galaxy, and that the suspicion is correct. Thus, the H II rotation velocities cannot be used to measure the mass distribution. The absorption-line rotation curve is used to derive the mass distribution, and it is found that the M/L ratio is nearly constant. It is concluded that the visible matter is self-gravitating at least in the central 180 arcsec. 44 references.
The radial distribution of the neutron field in the core of Dalat reactor
International Nuclear Information System (INIS)
Determining the radial distribution of the thermal neutron field in the core of the Dalat reactor was done by the Cu foil activation method. The measured data were fitted by the least square method to determine some physical parameters of the reactor, as follows: 1. Laplacian: B_r"2 = (84.6 +- 5.5)10_-_4/,cm"2. 2. The effective radius: R_e_f_f = (27.6 +- 1.0)cm. 3. The extrapolation distance: #lambda#_r = (8.7 +- 1.0)cm. 4. The unequal coefficient of the effective multiplication: k_r = 1.77 +- 0.11. (author). 3 refs., 4 figs., 1 tab.
1992-01-01
On the radial distribution of gamma rays in the outer galaxy
International Nuclear Information System (INIS)
The authors describe a new method which makes it possible to determine the radial distribution of the diffuse component of galactic gamma rays outside the solar circle. They use the observation that a good correlation exists between gamma-ray intensities and total column densities of the local interstellar gas and that the fractional column density of H_2<0.1 HI outside the solar circle. Thus the gamma-ray intensities are shown to be proportional to N(HI). The authors use the kinematics of the HI to determine the distances from which various fractions of the emission originate in the second and third galactic quadrants. Preliminary results of our analysis show that a significant flux of gamma rays originates from distances as large as 18 kpc from the galactic centre. (Auth.).
1982-08-04
Calculating electron dose using a convolution/superposition method. 120
International Nuclear Information System (INIS)
The calculation of electronn beam dose using an algorithms similar to convolution/superposition methods for photon beams [1,2,3,4] is explored. The distribution of dose deposited by a number of monoenergetic, point-monodirectional electron pencil beams is first determined using the Monte Carlo method [5,6]. These elementary distributions are combined to model distributions that would result from the spectrum of incident energies and angles [6,7] present in a clinical beam. These modified distributions are then stored for use as kernels in the dose calculation. In the case of a homogeneous phantom, the relative fluence distribution is convolved with the stored kernels to obtain thhe dose distributions in 3 dimensions. Since the kernels cannot be assumed to be spatially invariant ...
Sensitivity-based optimal capacitor placement on a radial distribution feeder
Energy Technology Data Exchange (ETDEWEB)
Optimal capacitor placement determines the size, type, and location of capacitors to be installed on a radial distribution feeder that will reduce peak power and energy losses while minimizing the costs of investment and installation of the capacitor banks. This paper describes a sensitivity-based optimal placement of capacitors that employs a new load characterization scheme using a voltage-current-angle-logger. The proposed method allows modeling of loads of different power factors for different portions of the distribution feeder. The optimal solution is obtained by testing various combinations of capacitor banks (based on the smallest bank size specified by the user) and candidate nodes along the distribution feeder, and calculating the resultant savings. In order to reduce solution time, the candidate nodes are ranked according to their sensitivity factors. The highest ranking nodes are considered ...
1995-12-31
Prediction of drug particle size and content uniformity in low-dose solid dosage forms
British Library Electronic Table of Contents (United Kingdom)
Drug particle size distribution has a profound impact to the content uniformity in low-dose solid drug products. We derived theoretically the skewness of potency distribution as a function of particle size distribution and target dose. It was demonstrated that both skewness and coefficient of variation diverge simultaneously with inverse square root of the target dose. This scaling relation was observed in recent experiment and was verified by Monte Carlo (MC) simulation, which was employed for the first time to solve for the full potency distribution from a random retrieving model. When tested against the criteria from USP uniformity of dosage units, MC simulation showed a striking anisotropic distribution of the data. This suggests a full-scale consideration of the potency distribu...
2010-01-01
Organ doses and integral doses in X-ray diagnosis of the chest and of the head
International Nuclear Information System (INIS)
Organ and tissue doses and integral doses in patients due to diagnostic x-ray examinations of the chest and of the head will be presented. These data have been obtained by measuring the dose distributions in man phantoms by LiF-dosimetry. The data will be compared with data obtained by Monte-Carlo calculations. To obtain average organ doses for a special type of examination for the population or for a specified subpopulation in the variation of the exposure, data due to the different techniques used by the different radiologists has to be known. Such data will be presented. The results of the investigation will be discussed in connection with the concept of the 'somatic significant.
1977-04-01
28: Calculation of 3D dose distribution for photons in inhomogeneous media
International Nuclear Information System (INIS)
A method for calculation of absorbed dose distributions in three dimensions for 1-20 MeV photons is presented. The method uses convolution/superposition of photon fluence distributions with energy scattering kernels. Results for Co-60 and X-ray beams in homogeneous and inhomogeneous media are compared with measurements. Good agreement is found between calculations and measurements. 8 refs.; 3 figs.
Optimization of segment weight using simulated dynamics algorithm for beamlet-based IMRT
International Nuclear Information System (INIS)
With accurate calculation algorithms in inverse planning for beamlet-based intensity modulated radiotherapy (IMRT), it takes time to calculate the dose matrix, which represents the dose distribution of each beamlet element to each voxel for unit fluence. To reduce the calculation time, coarse or approximate algorithms are often a choice, but this results in a final dose distribution that cannot reflect the real value. In addition, it is necessary to test if a coarse algorithm is capable of calculating the dose matrix of beamlets. In this work, simulated dynamics optimization algorithm was applied to optimize the segment weight to minish the dose error from the dose matrix calculation. After calculating the dose matrix by ray-tracing algorithm which takes into account just the primary component of ...
2007-08-01
Radial Halbach Magnetic Bearings
Radial Halbach magnetic bearings have been investigated as part of an effort to develop increasingly
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL ...
1991-06-01
Energy Technology Data Exchange (ETDEWEB)
The completed ribbon-winding theory, including temperature loading of the high-pressure compound vessel, was proposed. The influence of the bending stress in the wound ribbon is taken into account. Internal core of the compound vessel consists of matrix and ring, made of different materials. The relations were derived in analytical form, describing the radial distribution of necessary tangential prestressing.
1996-11-01
Estimation of errors provided with dead times of roentgen digital tomography
International Nuclear Information System (INIS)
Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computer tomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained
A microscopic description of neutron-rich lithium isotopes
International Nuclear Information System (INIS)
A unified calculation of neutron-rich isotopes in lithium is performed using the hyperspherical basis in which the underlying symmetry of each isotope exhibits a simple structure. The variation of the binding energy as a function of mass number is qualitatively reproduced, and the asymptotic of radial distribution of each isotope decreases exponentially. The form factors of the lithium isotopes are calculated and display diffraction minima. 27 refs., 3 figs., 3 tabs.
RADIAL DISTRIBUTION OF STARS, GAS AND DUST IN SINGS GALAXIES. I. SURFACE PHOTOMETRY AND MORPHOLOGY
International Nuclear Information System (INIS)
We present ultraviolet through far-infrared (FIR) surface brightness profiles for the 75 galaxies in the Spitzer Infrared Nearby Galaxies Survey (SINGS). The imagery used to measure the profiles includes Galaxy Evolution Explorer UV data, optical images from Kitt Peak National Observatory, Cerro Tololo Inter-American Observatory, and Sloan Digital Sky Survey, near-IR data from Two Micron All Sky Survey, and mid- and FIR images from Spitzer. Along with the radial profiles, we also provide multi-wavelength asymptotic magnitudes and several nonparametric indicators of galaxy morphology: the concentration index (C 42), the asymmetry (A), the Gini coefficient (G), and the normalized second-order moment of the brightest 20% of the galaxy's flux (M-bar20). In this paper, the first of a series, we describe the technical aspects regarding the surface photometry, and present a basic analysis of the global and structural properties of the SINGS galaxies at different ...
2009-10-01
Application of a 3-beam #gamma# densitometer to two-phase flow regime and density measurements
International Nuclear Information System (INIS)
A method of using gamma radiation to determine the density and phase distribution in two-phase flows in pipes is described. Three collimated beams of radiation that pass through a pipe cross-section at different radial positions are used. A theory and computer program used to relate the measured attenuation of these beams to a three-parameter model of the phase distribution and to the average density and void fraction are discussed. Data obtained during both static and dynamic verification experiments using Lucite inserts are presented, as well as the results of several tests done in high pressure, steam-water flows.
1976-08-11
EFFECT OF ANATOMIC MOTION ON PROTON THERAPY DOSE DISTRIBUTIONS IN PROSTATE CANCER TREATMENT
UK PubMed Central (United Kingdom)
PurposeTo determine the dosimetric impact of inter-fraction anatomical movements in prostate cancer patients receiving proton therapy.Full Text Available
2007-02-01
The spatial distribution of argon clusters in gas jet
International Nuclear Information System (INIS)
The spatial distribution of argon clusters in gas jet is tested using the Rayleigh scattering method. A pulsed laser is used to acquire the whole evolution of the cluster inside one event. The measured results at a fixed axial position show that the argon clusters grow in less than one millisecond after the nozzle is opened and the cluster size keeps constant during the whole open period of 20 ms. Further results show that the scattering signal along the radial direction is almost Gaussian-distributed and the full width half maximum (FWHM) increases almost linearly when the distance from nozzle increases. The scattering signal along the axial direction is Landau-distributed and the area near the nozzle is most effective for laser cluster interaction. (authors)
2010-02-01
Radial distribution of material in a bond mill determined by radiotracer-technique
International Nuclear Information System (INIS)
A steadily increasing part of comminution is nowadays carried out by tube ball mills. Our investigations are a first step to a possible tuning of material distribution with mechanical stress characteristic of the grinding media charge, that is essential for a high efficiency of grinding. A BOND mill filled with porcelain balls as grinding media and labelled corundum (Au-198) as grinding material was used to measure the distribution of material over the cross-section. The evaluation was made by linear interpolation between all combinations of adjacent measuring points to calculate all coordinates with equal intensity for each selected level of activity. Two plottings showing the dependence of material distribution on the rotating speed are presented. (author).
1985-09-23
British Library Electronic Table of Contents (United Kingdom)
The homogeneity of a helium dielectric barrier discharge, working at atmospheric pressure and containing oxygen as contaminant, is assessed by mapping the spatial distribution of oxygen metastable atoms in relation to the uniformity of surface properties. Tunable diode laser absorption spectroscopy is used to monitor the time evolution of the absorption coefficient corresponding to the oxygen metastable atoms on the 35S2 level, as a function of the laser absorbing path, whereas bi-dimensional Abel transform is used to obtain local information on the space distribution of the metastable atoms in the discharge. The radial distribution of the surface properties is investigated using atomic force microscopy, contact angle measurement and X-ray photoelectron spectroscopy. The results show that ...
2011-01-01
Retrospective Monte Carlo dose calculations with limited beam weight information
International Nuclear Information System (INIS)
An important unresolved issue in outcomes analysis for lung complications is the effect of poor or completely lacking heterogeneity corrections in previously archived treatment plans. To estimate this effect, we developed a novel method based on Monte Carlo (MC) dose calculations which can be applied retrospectively to RTOG/AAPM-style archived treatment plans (ATP). We applied this method to 218 archived nonsmall cell lung cancer lung treatment plans that were originally calculated either without heterogeneity corrections or with primitive corrections. To retrospectively specify beam weights and wedges, beams were broken into Monte Carlo-generated beamlets, simulated using the VMC++ code, and mathematical optimization was used to match the archived water-based dose distributions. The derived beam weights (and any wedge effects) were then applied to Monte Carlo beamlets regenerated based on the patient computed tomography ...
2007-01-01
The effects of thiamin on lead metabolism: organ distribution of lead 203.
UK PubMed Central (United Kingdom)
The effect of thiamin on the organ distribution of lead was evaluated in CD-1 mice exposed intragastrically or intraperitoneally to a single dose of lead acetate (100 micrograms) containing 100 microCi...Full Text Available
1992-07-01
Radiation risk in diagnostic radiology
International Nuclear Information System (INIS)
An attempt was made to quantify the radiation risk of diagnostic radiology. After a general introduction of terms as radiation damage, radiation risk and effective dose equivalent, based on publications of the ICRP, somatic dose indexes were computed for several radiologic investigations, that comprise organ doses committed to red bone marrow, lung, female breast and thyroid with and without considering the rest of the body. The dose for the rest of the body was assumed to be equal to the dose received by the red bone marrow, that is also distributed over the whole body. Neglecting the exposure of the rest of the body resulted in an insignificant increase in the estimated somatic risk, with its experimental determination not being necessary. (author).
1984-01-01
British Library Electronic Table of Contents (United Kingdom)
Most active pharmaceutical ingredients (API) exhibit particle size distributions with some degrees of asymmetry deviating from log-normality. A new log-skew-normal (L-S-N) distribution model is proposed for a systematic comparison of the asymmetry effect on content uniformity. The new model originated from the S-N model used by Azzalini gives a close approximation to real API particle size distribution. Monte-Carlo method was employed to simulate the dosage potency distribution. A high risk of over potency is uncovered when either the dose is low or API particle size distribution is positively skewed. This is due to the formation of pseudo heavy tail in potency distribution that decays slower than exponentially. Nomographs of API particle size versus dosage strength were constructed with a...
2010-01-01
Distribution of activation energies for impurity hopping in amorphous metals
Energy Technology Data Exchange (ETDEWEB)
The distribution of activation energies ..delta.. for classical over-the-barrier hopping is computed for a model amorphous metal. The spread in ..delta.. is determined by the variation in equilibrium-site and saddle-point sizes for the assumed model of dense random packing (DRP) of soft spheres. The size distribution is related to the radial distribution function in a manner which reproduces recent numerical results for the interstitials in DRP models. Size (distance) variation in general is related to energy variation by the form of the potential energy V(r). We show, however, that the distribution of equilibrium-site energies can be related directly to the impurity-induced lattice expansion and bulk modulus without detailed knowledge of V(r). The form of V(r) is necessary for the saddle-point distribution, and we estimate this using simple analytic expressions ...
1983-02-15
Energy Technology Data Exchange (ETDEWEB)
The thermal contact resistance between balls and inner and outer rings of thermally steady space-use deep groove ball bearings was studied experimentally to verify the validity of the previously proposed calculation method for the resistance. The 440C stainless steel single row bearing was used for measuring its steady state temperature distributions in a vacuum environment under axial, radial and combined load conditions. As a result, the experimental results of the resistance well agreed with calculated ones under each load condition resulting in the sufficient validity at nearly the same surface roughness. It was necessary to apply a static equivalent radial load to calculation under the combined load that a contact angle is larger than the angle of resultant force dependent on both load components. In experiments under only radial load, measurement of outer ring temperatures was necessary at some ...
1992-12-05
Study on dose distribution of therapeutic proton beams with prompt gamma measurement
Energy Technology Data Exchange (ETDEWEB)
The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma ...
2007-03-15
Energy Technology Data Exchange (ETDEWEB)
The performance of the new combustor was tested. Experiments showed that this combustor has superior insulating quality than the previous one. Measured radial concentrations indicated uniform distribution of the primary fuel (coal) inside the fire tube resulting in reasonably flat concentration profiles. However, measured radial concentrations after the addition of the reburn fuel showed uneven distribution of the fuel resulting in parabolic concentration profiles, an indication of insufficient mixing in the reburn zone. In order to study mechanisms of nitrogenous species destruction in the reburn zone, it is necessary to achieve adequate mixing if the assumption of one dimensional plug flow behavior is to be valid. Thus, it became necessary to modify the injector design and the injection mode of the reburn fuel to achieve an adequate level of mixing which is the focus of this report. The results show ...
1989-08-25
Procedure for radiation dose control in irradiated tissues during electron-beam therapy
International Nuclear Information System (INIS)
The invention refers a procedure of radiation dose control in irradiated tissues during electron-beam therapy. It aims at meeting the planned radiation dose for diseased tissues and taking care of the healthy ones. Therefore, the dose distribution required is determined before irradiation in consideration of such factors as energy-dependence of detector sensitivity, self-absorption within the tissue, and relative biological effectiveness. Furthermore, the expected intensity distribution of secondary quantum radiation excited in the irradiated tissue is calculated. A radiation detector for local resolution is used for registration. During irradiation the calculated intensity distribution is compared with the measured one. The invention is applicable in radiation therapy with monoenergetic electron beams.
1984-11-08
Alpha-particle dose distribution effects at the cellular level
International Nuclear Information System (INIS)
Ionizing radiations that differ in number, size, and distribution of energy deposition events might be expected to cause different effects for the same absorbed dose. Furthermore, microdosimetry calculations suggest that large variations in biological effectiveness might be expected for internally deposited alpha-emitting radionuclides for the same absorbed dose, depending upon the specific activity and spatial distribution of the sources in tissue. The study described in this article was designed to demonstrate these phenomena in vitro. Cultured Chinese hamster ovary (CHO-K1 BH4) cells were exposed in vitro to inert, insoluble ceramic microspheres in zirconium dioxide labeled with "2"3"9Pu. The average exit energy of the 5.15 MeV alpha particle was calculated to be 4.3 MeV. Exposure times varied from four to seven hours to achieve the desired dose level.
1985-02-01
International Nuclear Information System (INIS)
Despite the widely recognized usefulness of the AAPM TG-43 brachytherapy dose calculation formalism, a straightforward application of this approach to describe the dose distribution about intravascular line sources as proposed by TG-60 may be difficult or even impossible, especially when these line sources emit low-energy photons or beta particles. The causes of these limitations are investigated and illustrated by means of some numerical examples. In order to solve the observed limitations an adapted formalism is proposed, intended specifically for the description of the dose rate distribution about line sources but conceptually similar to the TG-43/TG-60 formalism. Several examples are presented to illustrate the usefulness of the proposed line source dose calculation formalism.
2001-04-01
Energy Technology Data Exchange (ETDEWEB)
IMRT with inverse planning allows simultaneous integrated boost strategies that exploit the heterogeneous dose distribution within the planning target volumes (PTVs). In this scenario, the location of cold spots within the target becomes a crucial issue and has to be related to the distribution of the clonogenic cell density (CCD). The main aim of this work is to provide the means to calculate the optimal prescription dose in a relative inhomogeneous dose distribution. To achieve this, the prescription dose has to be assigned to obtain the same tumor control probability (TCP) as the ideal homogeneous distribution, taking into account different CCDs in different PTVs (i.e. visible and subclinical regions). An adapted formulation of the linear-quadratic model, within the F-factor formalism, has been derived to preserve a ...
2008-10-07
Effect of dose on lead retention and distribution in suckling and adult female mice
Energy Technology Data Exchange (ETDEWEB)
Single doses of lead (trace to 445 mg/kg) were administered per os to suckling and adult mice. Both groups exhibited dose-independent lead retention when doses of 4 to 445 mg/kg were administered. However, developmental differences in the fraction of initial dose (FID) retained were evident for all doses administered. A much larger FID was retained in both age groups following administration of carrier-free /sup 203/Pb. The results are consistent with a mechanism of gastrointestinal lead absorption comprising two or more processes. Developmental differences were also observed in organ lead concentration relative to whole body concentration for kidneys, skull and brain 6 days following lead administration. Lead retentions (relative to whole body retention) in brain and in bone were linearly related to dose of lead administered in both suckling and adult age ...
1980-01-01
TLD array for precise dose measurements in stereotactic radiation techniques
International Nuclear Information System (INIS)
We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the ...
1996-12-01
International Nuclear Information System (INIS)
Techniques for reducing computation time in 3D photon dose calculations are addressed with specific emphasis given to the convolution/superposition approach. A single polyenergetic superposition model calculating absorbed dose per incident photon fluence (Gy cm"2) was developed in terms of TERMA and a total energy deposition kernel (a total point spread function). A novel approach was devised for reducing calculation time. The method, named the CF method, was based on the use of a conventional, fast model (here a modified power-law method was used) for the generation of 3D dose distributions on a fine dose matrix. Superposition calculations were carried out on a coarse matrix and calculation speed was increased simply by reducing the number of calculations. A set of correction factors was derived on the coarse grid from the ratio of the dose values from ...
1997-08-01
Study of dose variation in various body parts with respect to chest dose in the working environment
International Nuclear Information System (INIS)
Mixed Uranium Plutonium Carbide ((U, Pu) C), in the form of pellets encapsulated in stainless steel tubes is the fuel for Fast Breeder Test Reactor (FBTR) at Kalpakkam. For the fabrication of fuel for enlarging the core of this reactor, high burn up plutonium is used. The external exposure in these labs was significantly higher than that with low burn up Pu fuel. Dose evaluation to the organs was carried out using experimental TLDs during various operations of FBTR fuel fabrication to study the dose distribution pattern. (author)
2011-02-22
Cosmic-Ray Nuclei, Antiprotons and Gamma-rays in the Galaxy: a New Diffusion Model
We model the transport of cosmic ray nuclei in the Galaxy by means of a new numerical code. Differently from previous numerical models we account for a generic spatial distribution of the diffusion coefficient. We found that in the case of radially uniform diffusion, the main secondary/primary ratios (B/C, N/O and sub-Fe/Fe) and the modulated antiproton spectrum match consistently the available observations. Convection and re-acceleration do not seem to be required in the energy range we consider: $1 \\le E \\le 10^3$ GeV/nucleon. We generalize these results accounting for radial dependence of the diffusion coefficient, which is assumed to trace that of supernova remnants. While this does not affect the prediction of secondary/primary ratios, the simulated longitude profile of the diffuse $\\gamma$-ray emission is significantly different from the uniform case and may agree with EGRET measurements without invoking {\\it ad ...
2008-01-01
Photon beam modelling with Pinnacle3 Treatment Planning System for a Rokus M Co-60 Machine
International Nuclear Information System (INIS)
The basic relationships of the convolution/superposition dose calculation technique are reviewed, and a modelling technique that can be used for obtaining a satisfactory beam model for a commercially available convolution/superposition-based treatment planning system is described. A fluence energy spectrum for a Co-60 treatment machine obtained from a Monte Carlo simulation was used for modelling the fluence spectrum for a Rokus M machine. In order to achieve this model we measured the depth dose distribution and the dose profiles with a Wellhofer dosimetry system. The primary fluence was iteratively modelled by comparing the computed depth dose curves and beam profiles with the depth dose curves and crossbeam profiles measured in a water phantom. The objective of beam modelling is to build a model of the primary fluence that the patient is exposed to, which can ...
Static and dynamic muonic-atom codes-MUON and RURP
International Nuclear Information System (INIS)
Muonic-atom energy levels and wave functions are calculated. The results are corrected for nearly all important static effects, including finite nuclear size as produced by a user-specified nuclear charge distribution. Fourth-order Runge-Kutta integration of the radial Dirac equations, with the secant method determining the eigenvalues. Corrections are either included as potentials in the Dirac equations or computed as first-order perturbations. The code assumes spherical symmetry, so that effects of nuclear deformation may be treated only as static first-order perturbations. Dynamic muon-electron and muon-nuclear effects are neglected (the latter are calculated by RURP). (Auth.).
1979-02-01
Energy Technology Data Exchange (ETDEWEB)
This paper describes the design of a high-voltage negative ion source based on a magnetically insulated diode and generating microsecond pulses. Plane an cylindrical cathodes have been tested. The spatial and angular distributions of negative ions in the beam have been measured. The content of negative ions with different masses in the beam are given. The ion current density measured by a Faraday cup was up to 1 A/cm{sup 2} for the radial beam and 30-40 A/cm{sup 2}.
1995-10-01
Analysis on Dose Distribution in Heterogeneous Condition for Narrow 6 MV X-ray Beams
International Nuclear Information System (INIS)
Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous condition since the ...
2010-10-01
Energy Technology Data Exchange (ETDEWEB)
We present high-quality X-ray scattering experiments on pure water taken over a temperature range of 2 to 77 C using a synchrotron beam line at the advanced light source (ALS) at Lawrence Berkeley National Laboratory. The ALS X-ray scattering intensities are qualitatively different in trend of maximum intensity over this temperature range compared to older X-ray experiments. While the common procedure is to report both the intensity curve and radial distribution function(s), the proper extraction of the real-space pair correlation functions from the experimental scattering is very difficult due to uncertainty introduced in the experimental corrections, the proper weighting of OO, OH, and HH contributions, and numerical problems of Fourier transforming truncated data in Q-space. Instead, we consider the direct calculation of X-ray scattering spectra using electron densities derived from density functional theory based on real-space ...
2003-03-01
Tissue Heterogeneity in IMRT Dose Calculation for Lung Cancer
International Nuclear Information System (INIS)
The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the ? function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the lung and in the tumor area. These differences are not always in DVH of the lung, although the Wilcoxon test indicated ...
2011-01-01
MAPLE/HANARO type fuel element two-phase flow parameter measurement by real-time neutron radiography
Energy Technology Data Exchange (ETDEWEB)
The objective of this work is the measurement of two-phase flow parameters to support development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR). A single element finned Fuel Element Simulator was used with R134a Freon flow. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distributions were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly ...
2002-07-01
MAPLE/HANARO type fuel element two-phase flow parameter measurement by real-time neutron radiography
International Nuclear Information System (INIS)
The objective of this work is the measurement of two-phase flow parameters to support development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR). A single element finned Fuel Element Simulator was used with R134a Freon flow. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distributions were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly ...
2002-08-11
Finned fuel element two-phase flow parameter measurements using real-time neutron radiography
International Nuclear Information System (INIS)
The measurement of two-phase flow parameters and development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR) is discussed in this paper. A single element finned Fuel Element Simulator (FES) was used with R134a Freon as the working fluid. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distribution were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the ...
2007-04-22
Finned fuel element two-phase flow parameter measurements using real-time neutron radiography
International Nuclear Information System (INIS)
The measurement of two-phase flow parameters for development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR) is discussed in this paper. A single element finned Fuel Element Simulator (FES) was used with Freon 134a as the working fluid. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer present. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distribution were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, ...
2008-02-01
Principles of protection: a formal approach for evaluating dose distributions
International Nuclear Information System (INIS)
One of the central issues in radiation protection consists in determining what weight should be given to individual doses in relation to collective or aggregated doses. A mathematical framework is introduced in which such assessments can be made precisely in terms of comparisons between alternative distributions of individual doses. In addition to evaluation principles that are well known from radiation protection, a series of principles that are derived from parallel discussions in moral philosophy and welfare economics is investigated. A battery of formal properties is then used to investigate the evaluative principles. The results indicate that one of the new principles, bilinear prioritarianism, may be preferable to current practices, since it satisfies efficiency-related properties better without sacrificing other desirable properties.
2006-03-01
A compensating method of an imaging plate response to clinical proton beams
Energy Technology Data Exchange (ETDEWEB)
For charged particle irradiations, the response of an imaging plate (IP) changes around the Bragg peak. Therefore, an appropriate compensation is necessary for the evaluation of dose distribution formed by charged particles such as protons. In this paper, the response of IPs to clinical proton beams is investigated. An experimentally-obtained depth-dose distribution (an ordinary Bragg curve) by a silicon semiconductor detector (SSD) is employed to evaluate the compensation factors as a function of proton penetrating depth, i.e. residual range. A typical dose distribution in a water phantom formed by an L-shaped bolus is measured by IPs and corrected by using the information of those compensation factors; the residual proton range is successfully calculated by the pencil beam algorithm at an arbitrary point. The results show a good agreement with the measurements ...
2002-04-01
On the evolution of supernova remnants: Pt. 2
International Nuclear Information System (INIS)
Supernova explosions within wind-driven bubbles are studied with 2D hydrodynamical calculations. Two different density distributions for the ejecta are considered: (i) a smooth, unfragmented power-law stratification, and (ii) a fragmented distribution. As in 1D models, the presence of the shell of interstellar swept-up matter causes the rapid evolution of the remnant to the radiative phase. The main 2D effects, for both fragmented and unfragmented ejecta, include: (i) substantial chaotic deviations from a purely radial flow in the remnant interior, (ii) efficient turbulent mixing between the ejecta and the shocked wind, resulting in homogenization of the former wind cavity, and (iii) severe distortion of the wind-driven shell by cooling and Rayleigh-Taylor instabilities. (author).
British Library Electronic Table of Contents (United Kingdom)
All-atom molecular dynamics simulations were used to study the morphology of polymer/inorganic composite particles prepared by heterocoagulation. The results were also compared to those of our previous study of the preparation of TiO2/poly(acrylic acid-co-methyl methacrylate) and Fe3O4/polystyrene composite particles. In the simulation system, polymer or inorganic particles were simulated by surface-charge-modified C60 or Na atoms. Through a combination of analysis of the radial distribution functions of charged atoms and snapshots of the equilibrated structure, three kinds of particle distributions were observed under different conditions. When the polymer and inorganic particles had opposite surface charges and their sizes were very different, the composite morphology showed a core-shell...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
An all-atom polarizable chloroform (CHCl{sub 3}) potential model has been developed using the classical molecular dynamics techniques. This potential is shown to reproduce reasonably well the structural, dynamical, and thermodynamic properties of bulk liquid CHCl{sub 3} at various temperatures and pressures. With this potential, we carried out computer simulations to investigate the CHCl{sub 3}-H{sub 2}O liquid/liquid interface. Detailed structural and electrical properties at the interface will be analyzed via the density profile, radial distribution functions, molecular orientation, hydrogen bonding, and the z-dependent dipole distributions. Comparison will also be made to the results of the CCl{sub 4}-H{sub 2}O liquid/liquid interface.
1996-10-01
Energy Technology Data Exchange (ETDEWEB)
The authors describe a small doubly reflecting research furnace. Its optical components, a heliostat and a concentrating array of hexagonal-in-plan-form mirrors, focus sunlight at the aperture of a cavity receiver. A perfect paraboloid of revolution would have given higher concentration ratios. But large paraboloids are difficult to make and manipulate. Small hexagons are convenient and can be close packed. Spherical mirrors centered on a sphere simplified construction and were economical. In this note they use a simple model to describe the radial distribution of the normal flux at the focus of such an array. A schematic representation of a cross section of the concentrator mirror array in a plane which includes its axis is shown.
1984-02-01
Tumour control probability (TCP) for non-uniform activity distribution in radionuclide therapy
Energy Technology Data Exchange (ETDEWEB)
Non-uniform radionuclide distribution in tumours will lead to a non-uniform absorbed dose. The aim of this study was to investigate how tumour control probability (TCP) depends on the radionuclide distribution in the tumour, both macroscopically and at the subcellular level. The absorbed dose in the cell nuclei of tumours was calculated for {sup 90}Y, {sup 177}Lu, {sup 103m}Rh and {sup 211}At. The radionuclides were uniformly distributed within the subcellular compartment and they were uniformly, normally or log-normally distributed among the cells in the tumour. When all cells contain the same amount of activity, the cumulated activities required for TCP = 0.99 (A-tilde{sub TCP=0.99}) were 1.5-2 and 2-3 times higher when the activity was distributed on the cell membrane compared to in the cell nucleus for {sup 103m}Rh and {sup 211}At, ...
2008-08-21
International Nuclear Information System (INIS)
Full text: An adaptive response is a decreased biological effect induced by a priming radiation dose given prior to a challenge dose. Adaptive responses contradict the linear-nothreshold model of risk estimation. The pKZ1 mouse chromosomal inversion assay is an extremely sensitive assay for studying the mutagenic effect of low dose radiation. A non-linear dose response for chromosomal inversion has been observed in pKZ1 spleen and prostate after a single whole body irradiation with doses between 1?Gy and 10mGy. Doses between 5-10?Gy resulted in an induction in inversions and doses between 1-10mGy resulted in a reduction below endogenous inversion frequency. These results suggest that doses in the 1-10 mGy range cause host responses which overcompensate by not only preventing inversions that would normally occur as a ...
2006-04-01
IMRT verification by three-dimensional dose reconstruction from portal beam measurements
International Nuclear Information System (INIS)
A method of reconstructing three-dimensional, in vivo dose distributions delivered by intensity-modulated radiotherapy (IMRT) is presented. A proof-of-principle experiment is described where an inverse-planned IMRT treatment is delivered to an anthropomorphic phantom. The exact position of the phantom at the time of treatment is measured by acquiring megavoltage CT data with the treatment beam and a research prototype, flat-panel, electronic portal imaging device. Immediately following CT imaging, the planned IMRT beams are delivered using the multiple-static field technique. The delivered fluence is sampled using the same detector as for the CT data. The signal measured by the portal imaging device is converted to primary fluence using an iterative phantom-scatter estimation technique. This primary fluence is back-projected through the previously acquired megavoltage CT model of the phantom, with inverse attenuation correction, to yield an ...
2002-08-01
An experimental study of the ventilation performance of cold-air distribution systems
Energy Technology Data Exchange (ETDEWEB)
The ventilation performance of cold-air distribution systems was investigated in a full-scale test room for three different designs of ceiling-mounted diffusers: a large square radial, a small square radial, and two linear diffusers. The supply air temperature was 38 F (3.3 C). Tests were conducted with internal heat loads and with and without furnishings. The local mean ages of air, air diffusion effectiveness, and contaminant-removal efficiency were measured using tracer gas techniques to assess the performance of the ventilation system in maintaining adequate air quality conditions in the occupied region. Air velocities and temperatures were also measured in the occupied region to calculate the air diffusion performance index (ADPI). It was found that the cold-air distribution system provided satisfactory air quality and thermal comfort conditions to the occupied region of the room. It was also found ...
1994-12-31
Lung dose calculations at kilovoltage x-ray energies using a model-based treatment planning system
International Nuclear Information System (INIS)
The determination of the dose to organs from diagnostic x rays has become important because of reports of radiation injury to patients from fluoroscopically guided interventional procedures. We have modified a convolution/superposition-based treatment planning system to compute the dose distribution for kilovoltage beams. We computed lung doses using this system and compared them to those calculated using the CDI3 organ dose calculation program. We also computed average lung doses from a simulated radiofrequency ablation procedure and compared our results to published doses for a similar procedure. Doses calculated using this system were an average of 20% lower for AP beams and 7% higher for PA beams than those obtained using CDI3. The ratio of the average dose to the lungs to the skin ...
2001-02-01
Transmutation of technetium in the Petten HFR. A comparison of measurements and calculations
Energy Technology Data Exchange (ETDEWEB)
Within the framework of the EFTTRA cooperation between CEA, ECN, EDF, FZK, IAM and ITU, six metallic {sup 99}Tc rods have been irradiated in the Petten HFR for 193 effective full power days. During this irradiation, more than 6% of the {sup 99}Tc has been transmuted to the stable {sup 100}Ru. At ECN, one of the six rods has been examined in the hot cell laboratory. The ruthenium concentration in the rod measured by Isotope Dilution Mass Spectrometry reaches 6.4% at 5 mm from the bottom of the rod and 6.0% at 5 mm from the top. Also the axial and radial distributions of the ruthenium have been measured by Electron Probe Micro Analysis. The ruthenium concentrations calculated by the three-dimensional Monte Carlo code KENO reach 6.1% at 5 mm from the bottom of the rod and 5.7% at 5 mm from the top. These values are in reasonable agreement with the measured ones. However, the calculated radial distribution ...
1996-10-01
Estimation of frequency, population doses and stochastic risks in brachytherapy in Japan, 1983
International Nuclear Information System (INIS)
Based on the replies to a questionnaire distributed throughout Japan in 1983, genetically significant dose (GSD), per Caput mean bone marrow dose (CMD), leukemogenically significant dose (LSD), malignantly significant dose (MSD), and per Caput effective dose equivalent (EDE) from using small sealed radiation sources for radiotherapy were estimated. Annual frequencies of brachytherapy were estimated to be 2.6 x 10"3 for men and 36.3 x 10"3 for women, with a total of 38.9 x 10"3. The annual frequencies of using afterloading technique were 0.3 x 10"3 for men and 18.8 x 10"3 for women, with a total of 19.1 x 10"3. The annual population doses per person were 7.9 nGy for GSD, 118 #mu#Gy for CMD, 19.3 #mu#Gy for LSD, 172 #mu#Gy for MSD, and 428 #mu#Gy for EDE. The annual collective effective dose equivalent was estimated to be ...
1988-01-01
Body dose conversion factors for computerized tomography
International Nuclear Information System (INIS)
While there have been many experimental and calculational investigations on absorbed dose distribution in the patient resulting from conventional X-ray procedures, such data for computerized tomography (CT) are still sparse. As this diagnostic procedure has shown a rapid increase in application during recent years, we have determined absorbed dose to body organs in a human phantom resulting from CT examinations. The exposure model consists of the heterogeneous MIRD-5 phantom and a suitable Monte-Carlo method to calculate absorbed dose to organs of interest. The exposure conditions are specified according to the exposure specifications of a CT-scanner currently in use. The calculations cover the range of body tissues of interest in terms of organ absorbed doses as well as a risk weighted absorbed dose. A detailed example showing the calculation of red bone marrow ...
1980-10-31
Determinations of organ or tissue doses to survivors in Hiroshima and Nagasaki
International Nuclear Information System (INIS)
For the purpose of risk estimates from radiation carcinogenesis including leukemogenesis and radiation genetic effects, the biological significant dose is not the tissue kerma in air but the absorbed dose in organ or tissue with respect to carcinogenic and leukemogenic effects or genetic effects. In order to estimate organ or tissue dose from the tissue kerma in air, a ratio of the organ or tissue dose to the tissue kerma in air for survivors in Hiroshima and Nagasaki was calculated with the aid of the Snyder's mathematical phantoms constructed so as to simulate the body shape of survivors aged 5, 10 years old and adult at the time of atomic bomb detonations. The ratios were corrected for the angular distribution of atomic bomb radiations, assuming an anisotropic angular distribution for the survivors exposed to the atomic bombs in open air and the isotropic ...
1980-01-01
The impact of linac output variations on dose distributions in helical tomotherapy
UK PubMed Central (United Kingdom)
It has been suggested for quality assurance purposes that linac output variations for helical tomotherapy (HT) be within ±2% of the long-term average. Due to cancellation of systematic...Full Text Available
2008-01-21
UK PubMed Central (United Kingdom)
PurposeTo assess the prevalence and the dosimetric and clinical predictors of mandibular osteoradionecrosis (ORN) in patients with head and neck (HN) cancer who underwent...Full Text Available
2007-06-01
Recommended ERLs for whole body, thyroid, lung and other single organs are presented in tabular form, and related to the relevant counter measures such as evacuation, sheltering, distribution of stable iodine tablets, etc. Application of ERLs to local env...
1981-01-01
Clinical implementation of a convolution based algorithm for 3D treatment planning
International Nuclear Information System (INIS)
Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A computer ...
Fuel spray evolution; Comparison of experiment and CFD simulation of nonevaporating spray
Energy Technology Data Exchange (ETDEWEB)
Detailed spray characteristics were obtained for a small-capacity, pressure-swirl atomizer using an Aerometrics phase-Doppler particle analyzer. Measurements included drop size and velocity distributions, liquid volume fluxes, and air velocities at four axial locations, 25,50,75, and 100 mm, with complete radial traverses at each location. Drop size results were compared with measurements from a Malvern laser-diffraction instrument, and integrated liquid volume fluxes were compared with measured flow rates to estimate measurement uncertainties. Drop sizes measured by the two independent techniques and area-weighted-averaged over the radial traverses at each of the four axial stations varied on average by less than 4 percent. Integrated volume flux measurements by the phase-Doppler instrument at four axial stations differed from the nozzle flow rate by at most 19 percent, with some of the difference due to evaporation. The ...
1989-01-01
Energy Technology Data Exchange (ETDEWEB)
The thermal and heat transfer characteristics of stearic acid during the solidification processes were investigated experimentally in a vertical annulus energy storage system. The temperature distribution and temperature variations with time at different radial positions during the freezing processes were obtained. The thermal characteristics of the stearic acid, including movement of the solid-liquid interface in the radial direction, and the effects of Reynolds number on the heat transfer parameters were studied. The heat flux was estimated by using a simple approximate model. A new copper fin was designed and fixed to the electrical heating rod to enhance the thermal conductivity of the stearic acid. The results show that the new fin can enhance both the conduction and the natural convection heat transfer of the PCM, and the enhancement factor during solidification is estimated to be as high as 250%. The effect of the ...
2005-04-01
Energy Technology Data Exchange (ETDEWEB)
The thermal and heat transfer characteristics of stearic acid during the solidification processes were investigated experimentally in a vertical annulus energy storage system. The temperature distribution and temperature variations with time at different radial positions during the freezing processes were obtained. The thermal characteristics of the stearic acid, including movement of the solid-liquid interface in the radial direction, and the effects of Reynolds number on the heat transfer parameters were studied. The heat flux was estimated by using a simple approximate model. A new copper fin was designed and fixed to the electrical heating rod to enhance the thermal conductivity of the stearic acid. The results show that the new fin can enhance both the conduction and the natural convection heat transfer of the PCM, and the enhancement factor during solidification is estimated to be as high as 250%. The effect of the ...
2005-04-01
International Nuclear Information System (INIS)
The High Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory is one of the world's most powerful research reactors. In 1996, one year after the demise of the Advanced Neutron Source Project, the U.S. Department of Energy embarked on an aggressive program to upgrade the neutron scattering facilities at the HFIR. These upgrades, which are now in progress, include the installation of larger beam tubes, a high-performance hydrogen cold source, and additional neutron guides and neutron scattering instruments. An extensive analysis effort was performed over the past 4 yr to support the design of the modified beamlines and new user facilities and to assess the impact of the upgrades on the integrity of the existing reactor system. The results of three of these analyses are summarized here. Specifically, results are presented for analyses related to the design of the new cold neutron source (CNS), the assessment of beam tube changes on the anticipated pressure vessel lifetime, ...
2001-06-17
Energy Technology Data Exchange (ETDEWEB)
Radiographic images generated by the real-time neutron radiography system (RTNR) are analyzed by customized image processing software of the determination of instantaneous void fraction distribution. The cross-sectional averaged axial void fraction profiles and the two-dimensional void fraction profiles are determined simultaneously for each image. Various flow regimes are generated to determine if the RTNR system can accurately predict the void distribution in the radial, axial, and temporal coordinates. The results show the RTNR system correctly determines the void fraction distribution for each flow regime; however, accuracy decreases with decreasing void fraction. For net water thicknesses > 1.0 cm, the accuracy decreases with increasing water thickness due to the extreme sensitivity of thermal neutron interactions with light water. Heavy water is a more suitable fluid than light water for void ...
1995-01-01
Accumulation and distribution of "8"5Kr in rats exposed to "8"5Kr atmospheres
International Nuclear Information System (INIS)
Retention kinetics and tissue partition coefficients for "8"5Kr were determined in rats exposed to known concentrations of "8"5Kr gas. The tissue partition coefficients were used to calculate the relative tissue radiation dose, assuming exposure conditions equivalent to the maximum permissible concentration in air (MPC)a. The estimated radiation dose was highest in adrenals and body fat, about twice the dose estimated for the next highest tissue, ovaries. Saturation and desaturation curves show that the contents of the large intestines have a prolonged desaturation time compared to other samples analyzed.
1977-05-01
A dose computation algorithm used in MLC conformal treatment
International Nuclear Information System (INIS)
A dose calculation algorithm for MLC based conformal radiotherapy is described in this paper. The algorithm is formulated by the coordinate of MLC leaves. Verification on the algorithm is made by comparing the dose distributions generated by this algorithm with that generated by a Differential Convolution Superposition algorithm for various regular and irregular fields. The results demonstrate that the present algorithm has suitable accuracy and high computational efficiency, thus it could be useful for the treatment planning process in MLC based conformal radiotherapy, where the workload for interactively or automatically designing the shapes of MLC is heavy. (authors)
2007-12-01
The characterization of electron beam and its importance
International Nuclear Information System (INIS)
The necessity of the electron beam machine characterization via dose measurement is discussed. It includes a measurement of comprehensive dose distribution (at known X and Z axis) for verification of the machine performance. The acquired data were then used to develop the irradiation parameters such as energy, current, distance, conveyor speed, exposure rate and depth inside product to be irradiated. These parameters will be used as a guide for the routine irradiations. (Author)
2003-07-22
International Nuclear Information System (INIS)
CANDU 600 nuclear reactors are usually fuelled with STANDARD (STD), 37 rods fuel bundles. Natural uranium (NU) dioxide (UO_2), is used as fuel composition. A new fuel bundle geometry called CANFLEX (CFX) with 43 rods is proposed and some new fuel composition are considered. Flexibility is the key word for the attempt to use some different fuel geometries and compositions for CANDU 600 nuclear reactors as well as for innovative ACR-700/1000 nuclear reactors. The fuel bundle considered in this paper is CFX-RU-0.90 that encodes the CANFLEX geometry, recycled dioxide uranium (RU) with 0.90% enrichment. The goal of this proposal is ambitious: a higher average discharge burn-up up to 14000 MWd/tU and, for the same amount of generated electric power, reduction in nuclear fuel fabrication, reduction of spent nuclear fuel radioactive waste and reduction of refueling operational work by using fewer bundles. An improved sub-channel approach for thermal-hydraulic analysis is used in this paper to ...
2007-11-22
Measurement of dose distributions of linear energy transfer in matter irradiated by fast neutrons
Energy Technology Data Exchange (ETDEWEB)
A detector has been developed and used to measure dose distributions versus linear energy transfer to thin gas targets in spherical geometry from fast neutron irradiation of tissue-equivalent plastic and carbon. The detector is a hemispherical proportional counter with a Cs(T1) scintillator at the center of the hemisphere. The coincidence of the proportional counter signals constrain the measurements to charged particles traversing the radius of the hemisphere. The charged particle energy deposition distributions are directly measured for a known pathlength. The A-150 kerma factor was measured at a neutron energy of 14.8 MeV and is in agreement with tabulated values. The carbon kerma factor measurements are less than the tabulated value at 14.8 MeV. The alpha-particle production in carbon was measured for neutron energies from 14.1 to 14.8 MeV and is compared with existing data.
1990-01-01
Tissue Heterogeneity in IMRT Dose Calculation for Lung Cancer
British Library Electronic Table of Contents (United Kingdom)
The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the gamma function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the l...
2011-01-01
Tertiary-Butanol: A toxicological review
British Library Electronic Table of Contents (United Kingdom)
Tert-Butanol is an important intermediate in industrial chemical synthesis, particularly of fuel oxygenates. Human exposure to tert-butanol may occur following fuel oxygenate metabolism or biodegradation. It is poorly absorbed through skin, but is rapidly absorbed upon inhalation or ingestion and distributed to tissues throughout the body. Elimination from blood is slower and the half-life increases with dose. It is largely metabolised by oxidation via 2-methyl-1,2-propanediol to 2-hydroxyisobutyrate, the dominant urinary metabolites. Conjugations also occur and acetone may be found in urine at high doses. The single-dose systemic toxicity of tert-butanol is low, but it is irritant to skin and eyes; high oral doses produce ataxia and hypoactivity and repeated exposure can induce dependence...
2010-01-01
International Nuclear Information System (INIS)
Background and purpose: The low density of lung tissue causes a reduced attenuation of photons and an increased range of secondary electrons, which is inaccurately predicted by the algorithms incorporated in some commonly available treatment planning systems (TPSs). This study evaluates the differences in dose in normal lung tissue computed using a simple and a more correct algorithm. We also studied the consequences of these differences on the dose-effect relations for radiation-induced lung injury. Materials and methods: The treatment plans of 68 lung cancer patients initially produced in a TPS using a calculation model that incorporates the equivalent-pathlength (EPL) inhomogeneity-correction algorithm, were recalculated in a TPS with the convolution-superposition (CS) algorithm. The higher accuracy of the CS algorithm is well-established. Dose distributions in lung were compared using isodoses, ...
2003-10-01
The dust distribution in edge-on galaxies. Radiative transfer fits of V and K'-band images
Aims: I have analyzed a sample of seven nearby edge-on galaxies observed in the V and K'-band, in order to infer the properties of the dust distribution. Methods: A radiative transfer model, including scattering, have been used to decompose each image into a stellar disk, a bulge, and a dust disk. The parameters describing the distributions have been obtained through standard X^2 minimization techniques. Results: The dust disks fitted to the V-band images are consistent with previous work in literature: the radial scalelength of dust is larger than that for stars (h_d/h_s ~ 1.5); the dust disk has a smaller vertical scalelength than the stellar (z_d/z_s ~ 1/3); the dust disk is almost transparent when seen face-on (central, face-on, optical depth tau_0 =0.5-1.5). Faster radiative transfer models which neglect scattering can produce equivalent fits, with changes in the derived parameters within the accuracy of full fits ...
2007-01-01
International Nuclear Information System (INIS)
The purpose of this research is to investigate the micro-mechanism of deformation behavior of metallic glasses. We report the results of direct observations of short-range and medium-range structural change during tensile deformation of metallic glasses by high energy X-ray diffraction method. Cu50Zr50 and Ni30Zr70 metallic glass samples in the ribbon shape (1.5 mm width and 25 ?m) were made by using rapid quenching method. Tensile deformation added to the sample was made by using special equipment adopted for measuring the high energy X-ray diffraction. The peaks in pair distribution function g(r) for Cu50Zr50 and N30iZr70 metallic glasses move zigzag into front and into rear during tensile deformation. These results of direct observation on atomic distribution change for Cu50Zr50 and Ni30Zr70 metallic glass ribbons during tensile deformation suggest that the micro-relaxations occur.
2009-08-26
Determining the locations of faults in distribution systems
Energy Technology Data Exchange (ETDEWEB)
Location of transmission line faults are traditionally estimated by measuring the apparent impedance from a line terminal to the fault and converting the reactive component of the impedance to line length. None of the methods proposed to date address adequately the problems of fault location on distribution systems that have single or multiphase laterals and/or tapped loads. The research for this dissertation resulted in the development of a technique that estimates the location of a shunt fault on a radial distribution system that has several single and/or multiphase laterals. The technique takes into account load taps and non-homogeneity of the system, and has been tested for its ability to handle single-phase-to-ground, two-phase-to-ground, phase-to-phase and balanced three-phase faults. Computer simulations indicate that the technique is more accurate than the reactive component method. Results from a prototype of the ...
1998-12-01
The capric-lauric acid and pentadecane combination as phase change material for cooling applications
Energy Technology Data Exchange (ETDEWEB)
The mixture of 65 mol% capric acid and 35 mol% lauric acid (C-L acid) is a potential latent heat storage material. However, its melting temperature of 18.0 {sup o}C is quite high for low-temperature thermal energy storage. Addition of pentadecane, with a melting point of 9.9 {sup o}C, is proposed. The thermal characteristics of the combination of the C-L acid with pentadecane (CL:P) in different volume ratio are investigated employing the DSC analysis. The actual thermal performance of each CL:P combination is further determined from their radial and axial temperature distribution employing a fabricated thermal storage capsule. The 90:10 CL:P combination manifests an improvement in the melting characteristic of the C-L acid.(author)
2002-03-01
Effects of sawtooth crashes on beam ions and fusion product tritons in JET
Energy Technology Data Exchange (ETDEWEB)
The effect of a sawtooth crash on the radial distribution of the slowing down fusion product tritons and on beams ions, is examined with measurements of the 2.5 MeV and 14 MeV neutron emission line-integrals before and after sawtooth crashes. In deuterium discharges, the 14 MeV neutron production was wholly attributable to burnup of the 1 MeV fusion product tritons from d-d fusion. The local emissivity of 14 MeV neutrons, and hence of the profile of thermalizing tritons, is shown to be only weakly affected by crashes in the discharges studied. This is in contradiction with the apparent behaviour of injected beam ions as deduced from a study of the considerable changes in local emissivity of the 2.5 MeV neutrons. Nevertheless, the behaviour of the fusion product tritons is consistent with the scaling of the beam injected deuterium. 1 ref., 6 figs.
1994-07-01
Effect of Kerr nonlinearity on an Airy beam
International Nuclear Information System (INIS)
The effect of Kerr nonlinearity on an Airy beam is investigated by using the nonlinear Schroedinger equation. Based on the moments method, the evolution of the Airy beam width in the rms sense is analytically described. Numerical simulations indicate that the central parts of the major lobe of the Airy beam initially give rise to radial compression during propagation in a focusing medium, even though the rms beam width broadens. The partial collapse of the center parts of the major lobe of the beam appear below the threshold for a global collapse. The evolutions of the field distributions of the Airy beams are different during propagation in different Kerr media while the beams still travel along the parabolic trajectory just as the beam propagates in free space.
2010-10-01
CANDU 6 fuel behaviour in power ramp conditions
International Nuclear Information System (INIS)
The facilities in the Institute for Nuclear Research at Pitesti allow the testing, handling and examination of nuclear fuel and irradiated materials. The most important facilities are the TRIGA Steady State Research and Material Test Reactor and the Post-Irradiation Examination Laboratory (PIEL). The purpose of this work is to determine by post-irradiation examination, the behavior of CANDU fuel, irradiated in 14 MW TRIGA reactor. The fuel was irradiated in power ramp conditions. The results of post-irradiation examination are: - Visual inspection and photography of the outer appearance of sheath; - Profilometry (diameter, bending, ovality) and length measuring; - Determination of axial and radial distribution of the fusion products activity by gamma scanning and tomography; - Microstructural characterization by metallographic and ceramographic analyzes; - Mechanical properties determination. The data obtained from the post-irradiation ...
2009-10-12
International Nuclear Information System (INIS)
A number of procedures in diagnostic radiology and cardiology make use of long exposures to x-rays from fluoroscopy units. Although numerous studies have been performed to measure or calculate skin dose from these procedures, there have only been a handful of studies to determine the dose to the other organs. This thesis was focused on devising a method to calculate the absorbed dose to underlying tissues and organs. The work was performed in several stages. First, a commercial convolution/superposition-based treatment planning system used in radiation oncology was modified and complemented to make it usable with the low energies of x-rays used in diagnostic radiology. This required generation of energy deposition kernels in the kilovoltage energy range. The kernels were generated using the EGS4 Monte Carlo system of codes and added to the treatment planning system. The treatment planning system was then evaluated for its ...
2001-03-01
International Nuclear Information System (INIS)
Convolution/superposition (C/S) is regarded as the standard dose calculation method in most modern radiotherapy treatment planning systems. Different implementations of C/S could result in significantly different dose distributions. This paper addresses two major implementation issues associated with collapsed cone C/S: one is how to utilize the tabulated kernels instead of analytical parametrizations and the other is how to deal with voxel size effects. Three methods that utilize the tabulated kernels are presented in this paper. These methods differ in the effective kernels used: the differential kernel (DK), the cumulative kernel (CK) or the cumulative-cumulative kernel (CCK). They result in slightly different computation times but significantly different voxel size effects. Both simulated and real multi-resolution dose calculations are presented. For simulation tests, we use arbitrary kernels and ...
2005-02-21
Energy Technology Data Exchange (ETDEWEB)
Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin dose ...
2010-07-01
Direct aperture optimization of breast IMRT and the dosimetric impact of respiration motion
International Nuclear Information System (INIS)
We have studied the application of direct aperture optimization (DAO) as an inverse planning tool for breast IMRT. Additionally, we have analysed the impact of respiratory motion on the quality of the delivered dose distribution. From this analysis, we have developed guidelines for balancing the desire for a high-quality optimized plan with the need to create a plan that will not degrade significantly in the presence of respiratory motion. For a DAO optimized breast IMRT plan, the tangential fields incorporate a flash field to cover the range of respiratory motion. The inverse planning algorithm then optimizes the shapes and weights of additional segments that are delivered in combination with the open fields. IMRT plans were generated using DAO with the relative weights of the open segments varied from 0% to 95%. To assess the impact of breathing motion, the dose distribution for the optimized IMRT ...
2006-10-21
Is uniform target dose possible in IMRT plans in the head and neck?
International Nuclear Information System (INIS)
Purpose: Various published reports involving intensity-modulated radiotherapy (IMRT) plans developed using automated optimization (inverse planning) have demonstrated highly conformal plans. These reported conformal IMRT plans involve significant target dose inhomogeneity, including both overdosage and underdosage within the target volume. In this study, we demonstrate the development of optimized beamlet IMRT plans that satisfy rigorous dose homogeneity requirements for all target volumes (e.g., #+-#5%), while also sparing the parotids and other normal structures. Methods and Materials: The treatment plans of 15 patients with oropharyngeal cancer who were previously treated with forward-planned multisegmental IMRT were planned again using an automated optimization system developed in-house. The optimization system allows for variable sized beamlets computed using a three-dimensional convolution/superposition dose ...
2002-04-01
Radiological characterization of the GRR-1 pool
International Nuclear Information System (INIS)
GRR-1 is a 5MW open pool type research reactor with MTR-type fuel elements cooled and moderated by light water with beryllium reflectors at the two opposing sides of the core. A graphite thermal neutron column is adjusted to one side of the core. Six radial horizontal beam tubes are available, of which three contain in-pile collimators for neutron scattering instruments. The reactor is currently out of operation for inspection and refurbishment purposes. The core has been dismantled and the fuel elements are stored in the used fuel storage tank. The GRR-1 inspection and refurbishment plan involves inspection and eventually replacement of the reactor's primary cooling circuit. The health physics procedures to be implemented during inspection of the main water outlet are divided in three stages: a) pool dose rate survey from pool top, b) pool drainage by decreasing water level in steps and c) inspection of the water main outlet. urpose of the ...
2007-11-05
International Nuclear Information System (INIS)
In the early period after the Chernobyl accident, analysis of patterns of "1"3"1I exposure of the human thyroid showed that contaminated milk was the basic source of "1"3"1I intake among the inhabitants of Russia. The equipment and techniques used for measurement of the "1"3"1I content in the thyroids of these individuals are described in this work. A model of the "1"3"1I intake, taking into account protective actions, and a method of thyroid dose calculation are discussed. The mean thyroid dose and frequency distributions of the thyroid doses to inhabitants of towns and villages of the Bryansk, Tula and Orel regions of Russia are presented. The mean dose to the thyroids of children living in the villages was 2 to 5 times higher than the dose to adult thyroids; for children living in the towns, the mean dose was 1.5 to 12 times higher. The ...
Effect of dose on lead retention and distribution in suckling and adult female mice
International Nuclear Information System (INIS)
Single doses of lead (trace to 445 mg/kg) were administered per os to suckling and adult mice. Both groups exhibited dose-independent lead retention when doses of 4 to 445 mg/kg were administered. However, developmental differences in the fraction of initial dose (FID) retained were evident for all doses administered. A much larger FID was retained in both age groups following administration of carrier-free "2"0"3Pb. The results are consistent with a mechanism of gastrointestinal lead absorption comprising two or more processes. Developmental differences were also observed in organ lead concentration relative to whole body concentration for kidneys, skull and brain 6 days following lead administration. Lead retentions (relative to whole body retention) in brain and in bone were linearly related to dose of lead administered in both suckling and adult age groups. ...
SLAROM-UF: Ultra fine group cell calculation code for fast reactor
International Nuclear Information System (INIS)
A cell calculation code SLAROM-UF was developed to improve calculation accuracy of effective cross sections for various fast reactor types. SLAROM-UF has a capability to calculate effective cross sections in ultra fine groups of about 100,000 below 50keV and in fine groups above the energy (maximum 900 groups). Resonance interaction among the fuel, the coolant, and the structure materials can be treated accurately even in a heterogeneous cell structure. Temperature can be set up freely in a cell by the ultra fine group calculation. Improvement in nuclear characteristics was observed in the analysis of JUPITER critical experiment, as 0.1% for criticality, 4% for sodium void reactivity, several % for radial reaction rate distribution, when SLAROM-UF was used instead of the typical cell calculation code. The effect of the ultra fine group calculation is remarkable in the non-leakage term of sodium void reactivity, and that of the fine group ...
International Nuclear Information System (INIS)
The hard-sphere radial distribution functions, g_H_S(r/d,#eta#), for the face-centered cubic and hexagonal close-packed phases have been computed by the Monte Carlo method at nine values of the packing fraction, #eta#[=(#pi#/6)#rho#d"3], ranging from 4% below the melting density to 99% of the close-packed density. The Monte Carlo data are used to improve available analytic expressions for g_H_S(r/d,#eta#). By utilizing the new g_H_S(r/d,#eta#) in the Henderson and Grundke method [J. Chem. Phys. 63, 601 (1975)], we next derive an expression for y_H_S(r/d,#eta#) [=g_H_S(r/d)exp#left brace##beta#V_H_S(r)#right brace#] inside the hard-sphere diameter, d. These expressions are employed in a solid-state perturbation theory [J. Chem. Phys. 84, 4547 (1986)] to compute solid-state and melting properties of the Lennard-Jones and inverse-power potentials. Results are in close agreement with Monte Carlo and lattice-dynamics calculations performed in this ...
1991-11-01
International Nuclear Information System (INIS)
Current methods to calculate dose distributions with organ motion can be broadly classified as 'dose convolution' and 'fluence convolution' methods. In the former, a static dose distribution is convolved with the probability distribution function (PDF) that characterizes the motion. However, artifacts are produced near the surface and around inhomogeneities because the method assumes shift invariance. Fluence convolution avoids these artifacts by convolving the PDF with the incident fluence instead of the patient dose. In this paper we present an alternative method that improves the accuracy, generality as well as the speed of dose calculation with organ motion. The algorithm starts by sampling an isocenter point from a parametrically defined space curve corresponding to the patient-specific motion trajectory. Then a ...
2005-04-01
Two-phase flow regime transition in large diameter vertical pipes
Energy Technology Data Exchange (ETDEWEB)
The two-phase flow regime transition in a large diameter (I.D.=200mm) vertical pipe was experimentally investigated using a dual-sensor optical probe. The flow transitions from bubbly to chum without an intermediate slug flow regime as the air flow rate is increased. The transition boundaries developed for bubbly to slug flow in small diameter pipes are compared to the bubbly to chum flow transition of the present experiment. The bubbly to chum transition occurs at a void fraction of about 0.15 compared to 0.25 for bubbly to slug transition in small diameter pipes. The radial distribution of bubble diameter, bubble frequency, bubble velocity and local void fraction were obtained using a dual-sensor optical probe at different flow conditions. The Probability Density Function (PDF) and Cumulative Distribution Function (CDF) of the bubble velocity and size are used to study the flow regime transition in the large diameter ...
2002-07-01
Two-phase flow regime transition in large diameter vertical pipes
International Nuclear Information System (INIS)
The two-phase flow regime transition in a large diameter (I.D.=200mm) vertical pipe was experimentally investigated using a dual-sensor optical probe. The flow transitions from bubbly to chum without an intermediate slug flow regime as the air flow rate is increased. The transition boundaries developed for bubbly to slug flow in small diameter pipes are compared to the bubbly to chum flow transition of the present experiment. The bubbly to chum transition occurs at a void fraction of about 0.15 compared to 0.25 for bubbly to slug transition in small diameter pipes. The radial distribution of bubble diameter, bubble frequency, bubble velocity and local void fraction were obtained using a dual-sensor optical probe at different flow conditions. The Probability Density Function (PDF) and Cumulative Distribution Function (CDF) of the bubble velocity and size are used to study the flow regime transition in the large diameter ...
2002-06-02
Time-Dependent 2D Modeling of Magnetron Plasma Torch in Turbulent Flow
International Nuclear Information System (INIS)
A theoretical model is presented to describe the electromagnetic, heat transfer and fluid flow phenomena within a magnetron plasma torch and in the resultant plume, by using a commercial computational fluid dynamics (CFD) code FLUENT. Specific calculations are presented for a pure argon system (i.e., an argon plasma discharging into an argon environment), operated in a turbulent mode. An important finding of this work is that the external axial magnetic field (AMF) may have a significant effect on the behavior of arc plasma and thus affects the resulting plume. The AMF impels the plasma to retract axially and expand radially. As a result, the plasma intensity distribution on the cross section of torch seems to be more uniform. Numerical results also show that with AMF, the highest plasma temperature decreases and the anode arc root moves upstream significantly, while the current density distribution at the anode is more ...
2008-06-01
We study the structure of the medium surrounding sites of high-mass star formation to determine the interrelation between the HII regions and the environment from which they were formed. The density distribution of the surroundings is key in determining how the radiation of the newly formed stars interacts with the surrounds in a way that allows it to be used as a star formation tracer. We present new Herschel/SPIRE 250, 350 and 500 mum data of LHA 120-N44 and LHA 120-N63 in the LMC. We construct average spectral energy distributions (SEDs) for annuli centered on the IR bright part of the star formation sites. The annuli cover ~10-~100 pc. We use a phenomenological dust model to fit these SEDs to derive the dust column densities, characterise the incident radiation field and the abundance of polycyclic aromatic hydrocarbon molecules. We see a factor 5 decrease in the radiation field energy density as a function of radial ...
2010-01-01
Approximate analysis of non-uniform gas flow through layered burdens
Energy Technology Data Exchange (ETDEWEB)
An approximate analyzing model was developed to predict the azimuth of zigzag streamline, the distribution ratio between two neighboring layers and the radial distribution among the layers of the gas passing through the shaft of blast furnace loaded in layers. The theoretical basis of the approximate analysis is composed of the material balance derived from the assumption that any stream line surrounded with two streamlines is isolated and no material transfer occurs through the tube wall, and of the energy theory that the stream tube and passage are formed so that the total pressure drop in the whole system is the minimum. The effects of the apparent angle of repose between two layers, the packing volume and the passage resistance on the non-uniform flow in the layer were evaluated on the basis of the model. The result calculated by the approximate analysis agrees with the result by the numerical analysis based on the ...
1988-02-01
Dosimetry for Total Skin Electron Beam Therapy in Skin Cancer
International Nuclear Information System (INIS)
Increasing frequency of skin cancer, mycosis fungoides, Kaposi sarcoma etc, it need to treatment dose planning for total skin electron beam (TSEB) therapy. Appropriate treatment planning for TSEB therapy is needed to give homogeneous dose distribution throughout the entire skin surface. The energy of 6 MeV electron from the 18 MeV medical linear accelerator was adapted for superficial total skin electron beam therapy. The energy of the electron beam was reduced to 4.2 MeV by a 0.5cmx90cmx180cm acryl screen placed in a feet front of the patient. Six dual field beam was adapted for total skin irradiation to encompass the entire body surface from head to toe simultaneously. The patients were treated behind the acryl screen plate acted as a beam scatterer and contained a parallel-plate shallow ion chamber for dosimetry and beam monitoring. During treatment, the patient was placed in six different positions due to be homogeneous ...
1992-06-01
Rapid administration of stable iodine is essential for the saturation and subsequent protection of the thyroid gland against the potential harm caused by radioiodines. This paper proposes the Dutch risk analysis that uses an atmospheric dispersion model to calculate the size of the zones around nuclear power plants where radiological thyroid doses for children might be sufficiently high to warrant iodine administration. Dose calculations for possible releases from the nuclear power plants of Borssele (The Netherlands), Doel (Belgium) and Emsland (Germany) are based on two scenarios in combination with a 1-y set of authentic, high-resolution meteorological data. The dimensions of the circular zones were defined for each nuclear power plant. In these zones, with a radius up to 50 km, distribution of stable iodine tablets is advised. PMID:20332130
2010-03-23
Characteristics of the 18 MeV medical linear accelerator 'NELAC-1018', 2. Electron beams
Energy Technology Data Exchange (ETDEWEB)
The performance and characteristics of a medical linear accelerator ''NELAC-1018'' for the electron beam therapy were discussed. Measurement of deep dose distribution revealed that the 80% range was 1.9 cm by 6 MeV, 2.8 cm by 9 MeV, 3.9 cm by 12 MeV, 4.9 cm by 15 MeV and 5.5 cm by 18 MeV. Iso-dose distribution with each tubus and cone showed a favorable flatness by any of the energies. The degree of flatness was extremely favorable, being +-1.7% or less.
1983-11-01
Dosimetry of iodine-123 iomazenil in humans
International Nuclear Information System (INIS)
The distribution of the central benzodiazepine receptor specific ligand iodine-123 iomazenil was investigated in seven human adults from whole-body scans, blood samples and urine collected up to 24 h after injection. Using 12 source organs, the MIRD method was applied to calculate the absorbed radiation dose of the radioligand in various organs. The urinary bladder wall (0.15 mGy/MBq), lower large intestinal wall (0.071 mGy/MBq) testes (0.044 mGy/MBq) and upper large intestined wall (0.038 mGy/MBq) received the highest absorbed doses. The average effective dose equivalent of "1"2"3I-IBZM for adults was estimated to be 0.033 mSv/MBq. (orig.).
International Nuclear Information System (INIS)
The purpose of this work was to study and quantify the differences in dose distributions computed with some of the newest dose calculation algorithms available in commercial planning systems. The study was done for clinical cases originally calculated with pencil beam convolution (PBC) where large density inhomogeneities were present. Three other dose algorithms were used: a pencil beam like algorithm, the anisotropic analytic algorithm (AAA), a convolution superposition algorithm, collapsed cone convolution (CCC), and a Monte Carlo program, voxel Monte Carlo (VMC++). The dose calculation algorithms were compared under static field irradiations at 6 MV and 15 MV using multileaf collimators and hard wedges where necessary. Five clinical cases were studied: three lung and two breast cases. We found that, in terms of accuracy, the CCC algorithm performed better overall than AAA ...
2007-07-07
International Nuclear Information System (INIS)
The purpose of this work was to study and quantify the differences in dose distributions computed with some of the newest dose calculation algorithms available in commercial planning systems. The study was done for clinical cases where large density inhomogeneities were present. Three dose algorithms were used: a pencil beam like algorithm, the anisotropic analytic algorithm (AAA), a convolution superposition algorithm, collapsed cone convolution (CCC) and a Monte Carlo program, voxel Monte Carlo (VMC++). The dose calculation algorithms were compared under static field irradiations at 6 MV and 15 MV using multileaf collimators and hard wedges where necessary. Five clinical cases were studied: three lung and two breast cases. We found that the CCC algorithm performed overall better than AAA compared to VMC++, but AAA remains an attractive option for routine use in the clinic due to ...
2007-06-01
Evaluation of the increase of superficial dose due to thermoplastic immobilizing in radiotherapy
International Nuclear Information System (INIS)
Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin dose ...
2010-08-18
Enhanced spectral discrimination through the exploitation of interface effects in photon dose data
International Nuclear Information System (INIS)
The convolution/superposition algorithm for computing dose from photon beams in radiation therapy planning requires knowledge of the energy spectrum. The algorithm can compute the dose for a polyenergetic beam as the weighted sum of the individual dose contributions from monoenergetic beams. In this study we exploit interface effects apparent in the dose distributions to discriminate among spectra of high energy photon beams. We have studied the sensitivity of the depth dose distribution to the energy components using a hypothetical beam for various field sizes and depths in water and water-lung-water media. Six theoretical spectra were simulated. We compared depth dose data from these spectra using three quantitative measures which are inherently free of normalization ambiguities: for homogeneous water, the ratio ...
2004-02-01
Assessing radiologic risk for population due to human activities
International Nuclear Information System (INIS)
The most important factor in assessing radiologic risk is ensuring scientific means for evaluation of the radioactive release impact upon humans and organisms. To evaluate quantitatively this impact not only knowledge of radioactivity distribution in these dynamical systems is necessary but also understanding the transfer mechanisms between ecosystem components is needed. Thus a complete radioecologic study appear to be very complex and needs defining the source term, dynamic description of radionuclides behavior in the ecosystem, estimation of radiation doses in the major components of the ecosystem and finally the effects of radiation doses upon different parts of the systems. A diagram of the steps implied in evaluation of the effects due to radioactive effluent release in the environment is presented and discussed. The following steps are described: - identification of radioactive sources, as well as their input rate. ...
2002-09-06
BDTPS The BNCT Treatment Planning System jointly developed at DIMNP and JRC/IE
The idea to couple the Treatment Planning System (TPS) to the information on the real boron distribution in the patient is the main added value of the new methodology set-up at DIMNP of University of Pisa, in collaboration with the JRC of Petten (NL). The methodology has been implemented in the new TPS, called BDTPS (Boron Distribution Treatment Planning System), which takes into account the actual boron distribution in the patient brain, while the standard TPS assumes a uniform boron distribution, absolutely far from the reality. Nowadays, Positron Emission Tomography (PET) is able to provide this in vivo information. The new TPS, based on the Monte Carlo technique, has been validated comparing the main BNCT parameters (thermal flux, boron dose, etc.) as measured during the irradiation of a special heterogeneous boron phantom (HEBOM), ad hoc designed, as calculated by the BDTPS and ...
2003-01-01
Shielding analysis of TAPP-3,4 end-shield
International Nuclear Information System (INIS)
This paper consists of shielding analysis of steel balls and water filled end shields of Indian Pressurized Heavy Water Reactors (PHWRs). The material composition inside lattice tube is entirely different neutronically as compared with the composition of end-shield. Due to variation of material composition in radial and axial directions and complex geometry, it is necessary to carry out 3-D analysis for reasonable prediction of neutron flux and gamma dose rates. In the present paper, shielding analysis of end-shield for 540 MWe PHWR has been carried out during reactor operating and shutdown conditions using Monte-Carlo code MCNP. Furthermore materials on the periphery and central portion of end shield are different. Therefore the analysis was carried out separately for annular portion and central portion of end shield. The dominating streaming paths through end shields were studied. Predictions compare well with the measurements at TAPS-4 ...
2006-11-13
Optimizing an analytical dose calculation algorithm for fast 2D calculations
International Nuclear Information System (INIS)
Previously, an analytical dose calculation algorithm for MLC-based radiotherapy was developed and commissioned, which includes a detailed model of various MLC effects as a unique feature [1]. The algorithm was originally developed as an independent verification of the treatment planning system's dose calculation and it explicitly modeled spatial and depth dependent MLC effects such as interleaf transmission, the tongue-and-groove effect, rounded leaf ends, MLC scatter, beam hardening, and gradual MLC transmission fall-off with increasing off-axis distance. Originally the algorithm was implemented in Mathematica trademark (Wolfram). To speed up the calculation time and to be able to calculate high resolution 2D dose distributions within a reasonable time frame (<2 s) the algorithm needs to be optimized and to be embedded in a user friendly environment. To achieve this goal, the ...
International Nuclear Information System (INIS)
In the convolution/superposition algorithm, the energy spectrum should be modified to make the reconstructed dose distribution consistent with the measured dose distribution. The energy spectrum, which gives the best agreement, is not determined uniquely depending on the reconstruction procedure. In this report, the effects of the characteristics of the energy spectrum on the calculation accuracy are evaluated by comparing the percentage depth dose (PDD) and beam profiles for the reference energy spectrum with those calculated for the modified spectrum in order to optimize the energy spectrum modification procedure when 4 and 10 MV X-ray beams are used. Decreasing the number of energy bins brought a larger decrease rate in the computation accuracy than a decrease rate in computation time. Further, the decrease of the number of energy bins led to a change of the energy spectrum. The ...
2003-06-01
International Nuclear Information System (INIS)
The model of transient enhanced diffusion of ion-implanted As is formulated and the finite-difference method for numerical solution of the system of equations obtained is developed. The nonuniform distribution of point defects near the interface and more accurate description of arsenic clustering are simultaneously taken into account. Simulation of As diffusion during rapid annealing gives a reasonable agreement with the experimental data. (authors)
2005-09-01
International Nuclear Information System (INIS)
In clinical applications, it is very important to accurately determine the range of a proton beam in a patient. Recently, a prototype prompt-gamma scanning system, called a prompt-gamma scanner (PGS), has been constructed at Hanyang University in Korea with the collaboration of the Korean national cancer center (NCC), based on a series of Monte Carlo simulations. The PGS system is composed of a prompt-gamma collimator, a CsI(Tl) scintillation detector, a multi-channel analyzer (MCA), a precision movement system, and an integrated readout system. The prompt-gamma collimator is designed to effectively shield high-energy neutrons from the proton beam passage and subsequent capture gammas. The PGS system can be used to scan the distribution of the prompt gammas in the patient from the proton beam passage. The distribution of the prompt gammas can then be used to determine the proton beam range or the distal dose edge in the ...
2007-09-21
The effect of solutes on defect distributions and hardening in ion-irradiated model ferritic alloys
International Nuclear Information System (INIS)
A series of nine model ferritic alloys were ion irradiated at #propor to#300 C using 2.5 MeV He ions to a dose of 1.4 x 10"2"1 ion/m"2, which corresponds to #propor to#0.1 dpa at a depth of 2 #mu#m and #propor to#3.5 dpa at the peak damage region which occurs at about 4 #mu#m deep. The resultant changes in hardness as a function of depth were measured using a Nanoindenter "t"r"a"d"e"m"a"r"k. TEM was used to investigate the defect distributions. The effect of various solutes, Cu and N in particular, but Mn and Ti as well, on the change of hardness and the defect distribution due to the ion irradiation are discussed. (orig.).
The denoising of Monte Carlo dose distributions using convolution superposition calculations
International Nuclear Information System (INIS)
Monte Carlo (MC) dose calculations can be accurate but are also computationally intensive. In contrast, convolution superposition (CS) offers faster and smoother results but by making approximations. We investigated MC denoising techniques, which use available convolution superposition results and new noise filtering methods to guide and accelerate MC calculations. Two main approaches were developed to combine CS information with MC denoising. In the first approach, the denoising result is iteratively updated by adding the denoised residual difference between the result and the MC image. Multi-scale methods were used (wavelets or contourlets) for denoising the residual. The iterations are initialized by the CS data. In the second approach, we used a frequency splitting technique by quadrature filtering to combine low frequency components derived from MC simulations with high frequency components derived from CS components. The rationale is to take the scattering ...
2007-09-07
An iterative filtered backprojection inverse treatment planning algorithm for tomotherapy
International Nuclear Information System (INIS)
Purpose: An inverse treatment planning algorithm for tomotherapy is described. Methods and Materials: The algorithm iteratively computes a set of nonnegative beam intensity profiles that minimizes the least-squares residual dose defined in the target and selected normal tissue regions of interest. At each iteration the residual dose distribution is transformed into a set of residual beam profiles using an inversion method derived from filtered backprojection image reconstruction theory. These 'residual' profiles are used to correct the current beam profile estimates resulting in new profile estimates. Adaptive filtering is incorporated into the inversion model so that the gross structure of the dose distribution is optimized during initial iterations of the algorithm, and the fine structure corresponding to edges is obtained at later iterations. A three dimensional, kernel based, ...
1995-07-15
Population exposure to power-frequency fields: concepts, components, and control
Energy Technology Data Exchange (ETDEWEB)
There are many sources of population exposures to power-frequency (50/60 Hz) electric and magnetic fields including household appliances and wiring, neighborhood distribution circuits, and high-voltage transmission lines. Bioeffects studies were unable to demonstrate that exposures to power-frequency fields can affect public health. Researcher have likewise been unable to show that the health effects of such exposures are negligible. State and federal regulatory agencies are, therefore, grappling with questions of whether and how to regulate the sitting or design of new extra high-voltage transmission lines so as to control the ground-level fields to which people are exposed. The purpose of this dissertation is to illuminate some of the exposure-related aspects of these question. A taxonomy of the relationship between field encounter and effect is developed to clarify the meaning of terms such as exposure and dose in the power-frequency ...
1986-01-01
Neutron capture therapy beam on the LVR-15 reactor
Energy Technology Data Exchange (ETDEWEB)
Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head phantom was mapped ...
1992-01-01
Neutron capture therapy beam on the LVR-15 reactor
International Nuclear Information System (INIS)
Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head phantom was mapped ...
1991-10-01
Thermal and heat transfer characteristics in a latent heat storage system using lauric acid
Energy Technology Data Exchange (ETDEWEB)
The thermal and heat transfer characteristics of lauric acid during the melting and solidification processes were determined experimentally in a vertical double pipe energy storage system. In this study, three important subjects were addressed. The first one is temperature distributions and temporal temperature variations in the radial and axial distances in the phase change material (PCM) during phase change processes. The second one is the thermal characteristics of the lauric acid, which include total melting and total solidification times, the nature of heat transfer in melted and solidified PCM and the effect of Reynolds and Stefan numbers as inlet heat transfer fluid (HTF) conditions on the phase transition parameters. The final one is to calculate the heat transfer coefficient and the heat flow rate and also discuss the role of Reynolds and Stefan numbers on the heat transfer parameters. The experimental results proved that the PCM melts ...
2002-12-01
DYNAMICS OF SOLIDS IN THE MIDPLANE OF PROTOPLANETARY DISKS: IMPLICATIONS FOR PLANETESIMAL FORMATION
International Nuclear Information System (INIS)
We present local two-dimensional and three-dimensional hybrid numerical simulations of particles and gas in the midplane of protoplanetary disks (PPDs) using the Athena code. The particles are coupled to gas aerodynamically, with particle-to-gas feedback included. Magnetorotational turbulence is ignored as an approximation for the dead zone of PPDs, and we ignore particle self-gravity to study the precursor of planetesimal formation. Our simulations include a wide size distribution of particles, ranging from strongly coupled particles with dimensionless stopping time #tau#_s #ident to# #OMEGA#t_s_t_o_p = 10"-"4 (where #OMEGA# is the orbital frequency, t_s_t_o_p is the particle friction time) to marginally coupled ones with #tau#_s = 1, and a wide range of solid abundances. Our main results are as follows. (1) Particles with #tau#_s #approx#> 10"-"2 actively participate in the streaming instability (SI), generate turbulence, and maintain the height of the ...
2010-10-20
Lead and calcium distributions in blood, plasma, and milk of the lactating mouse
Energy Technology Data Exchange (ETDEWEB)
Although it has been established that lead is transferred in milk from mother to suckling offspring, the physiological processes and parameters involved are not well understood. Single i.v. doses (0.2 mg/kg) or p.o. doses (2 mg/kg) of radiolabeled lead were administered to lactating and nonlactating female mice, and lead concentrations in blood, plasma, and milk were determined during a 21-day period. Large differences in lead elimination were observed between lactating and nonlactation mice. A significant fraction (25%) of the initial maternal dose (absorbed dose) was transferred to the suckling pups. The ratio of lead concentration in milk to lead concentration in plasma was found to be nearly constant over time. However, the milk-to-blood concentration ratios decreased during the same period. Furthermore, the concentration of lead in milk exceeded the plasma concentration by a factor of approximately ...
1980-01-01
UK PubMed Central (United Kingdom)
A single radial hemolysis test was developed for quantitation of specific antibody to non-hemagglutinating viruses. With the human coronaviruses as models, this test utilizes the binding properties...Full Text Available
1977-06-01
Magnetic resonance imaging findings in 46 elbows with a radial head fracture
UK PubMed Central (United Kingdom)
Background and purposeRadial head fractures are common, and may be associated with other injuries of clinical importance. We present the results of a standard additional MRI scan...Full Text Available
2010-06-01
British Library Electronic Table of Contents (United Kingdom)
The influence of geometry and operating conditions of the centrifugal compressor stage on the radial gas force is determined on the basis of the theoretical method and calculation program using experimental boundary conditions.
2011-01-01
Structure of molten alkali halides
Energy Technology Data Exchange (ETDEWEB)
The results of X-ray and neutron diffraction experiments on molten alkali halides in which some data of our experiments by X-ray diffraction such as those of molten LiCl, NaCl, KCl, LiBr and KBr are included were summarized. The first peak positions in the radial distribution function in molten alkali halides by X-ray or neutron diffraction experiments are always longer than those by computer simulations and the differences of 0.1 -- 0.3 A exceed the experimental error. It seems to be due to the deformation of the electron shell. In the computer simulation, the shell model which has the spherical deformation was expected to have a closer value of the first peak position to the experimental one than the rigid ion model by taking the polarization of ions. However, no change in the first peak position was found. Therefore, the non-spherical deformation of electron shell at the point where ions are in contact with each other has to be taken into ...
1982-06-01
Structure of molten alkali halides
International Nuclear Information System (INIS)
The results of X-ray and neutron diffraction experiments on molten alkali halides in which some data of our experiments by X-ray diffraction such as those of molten LiCl, NaCl, KCl, LiBr and KBr are included were summarized. The first peak positions in the radial distribution function in molten alkali halides by X-ray or neutron diffraction experiments are always longer than those by computer simulations and the differences of 0.1 -- 0.3 A exceed the experimental error. It seems to be due to the deformation of the electron shell. In the computer simulation, the shell model which has the spherical deformation was expected to have more closer value of the first peak position to the experimental one than the rigid ion model by taking the polarization of ions. However, no change in the first peak position was found. Therefore, the non-spherical deformation of electron shell at the point where ions are in contact with each other has to be taken into ...
1982-01-01
Structural ordering in liquid K-Te alloys
Energy Technology Data Exchange (ETDEWEB)
Neutron diffraction from molten K{sub x}Te{sub 1{minus}x} is reported for x = 0.12 and x = 0.50 semiconducting alloys. The measured radial distribution functions (rdf) demonstrate the persistence of covalently bonded tellurium in the liquid. The rdf of the liquid K{sub 0.12}Te{sub 0.88}, which is dominated by the Te-Te contribution, is remarkably similar to that of pure liquid tellurium, the notable exception being that the nearest neighbor peak is largely resolved and found to have a coordination number slightly less than 2. The K{sub 0.50}Te{sub 0.50} rdf clearly indicates Te-Te pairing in the melt, and unexpected departure from the presumed similar Cu{sub 0.50}Te{sub 0.50}. These paired tellurium are most likely of the form (Te{sub 2}){sup 2{minus}} Zintl ions.
1994-03-01
International Nuclear Information System (INIS)
The present work is to study effects of neutron irradiation on the structure of amorphous Pb_8_0 Si_2_0 and Pd_7_7_._5 Cu_6 Si_1_6_._5 alloys by using X-ray diffraction techniques. differential scanning calorimertry (DSC) and internal friction measurements. The irradiation will produce obvious changes in the pair correlation function g(r) and radial distribution function RDF (r). The increase of crystallization temperature (Tx) and enthalpy of two specimens were found by DSC measurements after irradiation. The results of internal friction measurement show that the internal friction of the irradiated Pd_8_0Si_2_0 alloy is higher than that of the unirradiated in the temperature range of T
Radiogauging to investigate two phase flow. Graduation report
Energy Technology Data Exchange (ETDEWEB)
New measuring methods are developed and are tested with the small reactor simulator MIDAS (Mini Dodewaard ASsembly). The purpose of this work is to be able to measure accurately as many different properties of the flow as possible in the coming bigger simulator SIDAS (Simulated Dodewaard ASsembly). In SIDAS the flow around a fuel assembly of the Dutch Dodewaard reactor will be simulated. An extensive evaluation of the gamma detection system showed that the detection system could be simplified strongly. The simplified system is used to measure the radial and axial distribution of the void fraction in the core of MIDAS for three different operating conditions. Two new measuring methods have been developed and tested. A method to estimate the probability density of the void fraction in time. Due to the nonlinear relation between transmission and void fraction the determined average value of the void fraction in general will contain a systematic ...
1992-11-12
Quark and Gluon Tagging at the LHC
Being able to distinguish light-quark jets from gluon jets on an event-by-event basis could significantly enhance the reach for many new physics searches at the Large Hadron Collider. Through an exhaustive search of existing and novel jet substructure observables, we find that a multivariate approach can filter out over 95% of the gluon jets while keeping more than half of the light-quark jets. Moreover, a combination of two simple variables, the charge track multiplicity and the pT-weighted linear radial moment (girth), can achieve similar results. While this pair appears very promising, our study is only Monte Carlo based, and other discriminants may work better with real data in a realistic experimental environment. To that end, we explore many other observables constructed using different jet sizes and parameters, and highlight those that deserve further theoretical and experimental scrutiny. Additional information, including distributions ...
2011-01-01
International Nuclear Information System (INIS)
Precisely measured differential cross sections for elastic and inelastic scattering from 104 MeV alpha-particles by _4_8Ca, _5_0Ti and _5_2Cr are reported. The analyses aim primarily at the determination of strength, radial shapes and deformation of the scattering potentials, looking for isotonic differences of N=28 isotones. The mean square radii of the (real) potentials are discussed in terms of mean square radius differences of the matter distributions. The isoscalar transition rates derived by coupled channel analyses of the measured cross sections are compared with electromagnetic rates. In addition to the analyses on the basis of a slightly generalized extended optical model a semi-microscopic deformed folding model has been applied, using a density-dependent effective alpha-bound nucleon interaction. Though an excellent description of the data over the full angular range is obtained the resulting values of the deformation parameters ...
Energy Technology Data Exchange (ETDEWEB)
Precisely measured differential cross sections for elastic and inelastic scattering from 104 MeV alpha-particles by /sup 48/Ca, /sup 50/Ti and /sup 52/Cr are reported. The analyses aim primarily at the determination of strength, radial shapes and deformation of the scattering potentials, looking for isotonic differences of N=28 isotones. The mean square radii of the (real) potentials are discussed in terms of mean square radius differences of the matter distributions. The isoscalar transition rates derived by coupled channel analyses of the measured cross sections are compared with electromagnetic rates. In addition to the analyses on the basis of a slightly generalized extended optical model a semi-microscopic deformed folding model has been applied, using a density-dependent effective alpha-bound nucleon interaction. Though an excellent description of the data over the full angular range is obtained the resulting values of the deformation ...
1983-08-01
Galactic open clusters are since long recognized as one of the best tools for investigating the radial distribution of iron and other metals. We employed FLAMES at VLT to collect UVES spectra of bright giant stars in a large sample of open clusters, spanning a wide range of Galactocentric distances, ages, and metallicities. We present here the results for four clusters: Berkeley 20 and Berkeley 29, the two most distant clusters in the sample; Collinder 261, the oldest and the one with the minimum Galactocentric distance; Melotte 66. Equivalent width analysis was carried out using the spectral code MOOG and Kurucz model atmospheres to derive abundances of Fe, Al, Mg, Si, Ca, Ti, Cr, Ni, Ba; non-LTE Na abundances were derived by direct line-profile fitting. We obtain subsolar metallicities for the two anticenter clusters Be 20 ([Fe/H]=-0.30, rms=0.02) and Be 29 ([Fe/H]=-0.31, rms=0.03), and for Mel 66 ([Fe/H]=-0.33, rms=0.03), located in the ...
2008-01-01
Monte Carlo methods, models, and applications to the advanced neutron source
Energy Technology Data Exchange (ETDEWEB)
This paper reports on three-dimensional continuous-energy coupled neutron-gamma Monte Carlo models of the Advanced Neutron Source (ANS) final preconceptual and conceptual reference core designs developed using the Monte Carlo Neutron and Photon transport code (MCNP) Version 3b. These models contain the reactor core with control rods, the heavy water reflector tank with shutdown rods and some beam tubes, and the outer light water pool. Eighty homogenized fuel zones per fuel element are used to represent the radial and axial {sup 235}U fuel distribution. These models are the most sophisticated, physically accurate reactor physics models of the ANS currently available. The use of MCNP methods and applications to the ANS are demonstrated. Beam tube studies, coolant voiding studies, and many criticality studies have already been performed, as have studies with variance reduction techniques. In comparison with deterministic methods, MCNP proves ...
1991-09-01
KINEMATICS AT THE EDGE OF THE GALACTIC BULGE: EVIDENCE FOR CYLINDRICAL ROTATION
International Nuclear Information System (INIS)
We present new results from BRAVA, a large-scale radial velocity survey of the Galactic bulge, using M giant stars selected from the Two Micron All Sky Survey catalog as targets for the Cerro Tololo Inter-American Observatory 4 m Hydra multi-object spectrograph. The purpose of this survey is to construct a new generation of self-consistent bar models that conform to these observations. We report the dynamics for fields at the edge of the Galactic bulge at latitudes b = -8 deg. and compare to the dynamics at b = -4 deg. We find that the rotation curve V(r) is the same at b = -8 deg. as at b = -4 deg. That is, the Galactic boxy bulge rotates cylindrically, as do boxy bulges of other galaxies. The summed line-of-sight velocity distribution at b = -8 deg. is Gaussian, and the binned longitude-velocity plot shows no evidence for either a (disk) population with cold dynamics or for a (classical bulge) population with hot dynamics. The observed ...
2009-09-10
In-pile measurements of fuel rod deformation and verification of the finite element model FEMAXI
International Nuclear Information System (INIS)
For safety evaluations and licensing procedures, fuel rod performance is predicted through model calculations. Due to the complexity of fuel rod performance and the insufficient availability of experimental data, such calculations necessarily reflect inaccuracies and conservatism. For verification and development of more realistic models and submodels, acquisition of reliable on-line data on fuel rod performance characteristics is imperative. The present paper describes the instruments and equipment applied in the Halden Reactor for on-line measurements of fuel rod and assembly power and power distribution, and fuel rod axial and diameter deformation. Recent results from evaluation of such fuel rod deformation measurements, covering fuel rods with different designs, subjected to various modes of operation, including startup ramps, steady state, and power shock, are presented. It is also shown how these data are used for verification and development of the ...
1976-09-13
Correlations are studied between the power density of Alfv\\'en-cyclotron waves (having frequencies between 0.02 and 2 Hz) and the ratio of the perpendicular and parallel temperature of the protons. The wave power spectrum is evaluated from high-resolution 3D magnetic field vector components, and the ion temperatures are derived from the velocity distribution functions as measured in fast solar wind during the Helios-2 primary mission at radial distances from the Sun between 0.3 AU and 0.9 AU. From our statistical analysis, we obtain a striking correlation between the increases in the proton temperature ratio and enhancements in the wave power spectrum. Near the Sun the transverse part of the wave power is often found to be by more than an order of magnitude higher than its longitudinal counterpart. Also the measured ion temperature anisotropy appears to be limited by the theoretical threshold value for the ion-cyclotron instability. This ...
2010-01-01
International Nuclear Information System (INIS)
Brachytherapy refers to short distance treatment of cancer with radiation from small, encapsulated radionuclide sources. This type of treatment is given by placing sources directly into or near the volume to be treated. The dose is then delivered continuously, either over a short period of time (temporary implants) or over the lifetime of the source to a complete decay (permanent implants). This technique is extensively used in the treatments of gynecological, breast, prostate, head and neck, and other soft tissue cancers. The clinical outcomes of this treatment depend on accurate dosimetry and dose delivery. The patient is generally considered to be water equivalent. So the treatment planning system software generally is based on measured or calculated dose distributions in homogenous water medium. In real situation, the treatment volume is not homogenous water medium, but it is a heterogeneous medium ...
2009-04-01
International Nuclear Information System (INIS)
The distribution of radiation dose commitments within the body that can result from the lung deposition of a number of transuranic radionuclides ("2"3"7Pu, "2"3"8Pu, "2"3"9Pu, "2"4"0Pu, "2"4"1Pu, "2"4"2Pu, "2"4"3Pu, "2"4"4Pu, "2"4"1Am, "2"4"2Am, "2"4"3Am, "2"4"4Am, "2"4"2Cm, "2"4"3Cm, "2"4"4Cm, and "2"4"6Cm) was calculated. The variables that influence these organ dose commitments include the mobility of the particle or its dissolution products within the body, the radiation characteristics of the inhaled radionuclides and their progeny, and the size of the particles inhaled. In the calculation of organ dose commitments for whole-body, lungs, liver, bone tissues, kidneys, and gastrointestinal tract from the inhalation of transuranium radionuclides, physical characteristics of importance are the dimensions of the particle, its aerodynamic properties, and its density. For particles within the respirable ...
1975-11-17
International Nuclear Information System (INIS)
... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,
2006-09-11
Development of radial-flow type internally oil-cooled oil-filled cable
Energy Technology Data Exchange (ETDEWEB)
A radial-flow type internally oil-cooled oil-filled cable has been developed. This system is characterized in that the oil flows radially through the paper insulation. The thermal resistance of the insulation is equivalently decreased by the radial-flow. The decreased thermal resistance as well as the cooling effect of the oil flow in the central oil duct and the outer oil duct under an aluminum sheath increase the current capacity. A calculation method of cooling characteristics is introduced. The stability of the cable and accessories was confirmed through initial electrical tests and a long-term field test.
1988-01-01
A study of flow boiling phenomena using real time neutron radiography
International Nuclear Information System (INIS)
The operation and safety of both fossil-fuel and nuclear power stations depend on adequate cooling of the thermal source involved. This is usually accomplished using liquid coolants that are forced through the high temperature regions by a pumping system; this fluid then transports the thermal energy to another section of the power station. However, fluids that undergo boiling during this process create vapor that can be detrimental, and influence safe operation of other system components. The behavior of this vapor, or void, as it is generated and transported through the system is critical in predicting the operational and safety performance. This study uses two advanced penetrating radiation techniques, Real Time Neutron Radiography (RTNR), and High Speed X-Ray Tomography (HS-XCT), to examine void generation and transport behavior in a flow boiling system. The geometries studied were tube side flow boiling in a cylindrical configuration, and a similar flow channel with an internal ...
1346-01-01
Dynamics of a very intense pulsed electron beam
Energy Technology Data Exchange (ETDEWEB)
A unique beam of pulsed electrons has been developed using the 19-MeV, 700-kA Hermes-III accelerator. The extended planar-anode diode is used to extract at large radius an annular electron beam from the accelerator and inject the resulting beam at small angle into a low-pressure gas cell, where the beam is rapidly charge neutralized and almost current neutralized. Under these conditions, the beam propagates nearly ballistically to a focus downstream of injection, where objects can be placed for irradiation and study. For a focal length of 78 cm, measurements with a segmented calorimeter show that this configuration can deliver an energy deposition of 200 J/g [20 Mrad] over a useful area of 70 cm{sup 2} and a 4-cm depth in graphite in 25 ns. Increasing the injection angle by reducing the AK gap permits higher doses over smaller areas to be achieved. Such beams are of interest for the study of material property changes from short-pulse high-energy depositions and for ...
1994-12-31
Energy Technology Data Exchange (ETDEWEB)
In radiation therapy with hadron beams, conformal irradiation to a tumour can be achieved by using the properties of incident ions such as the high dose concentration around the Bragg peak. For the effective utilization of such properties, it is necessary to evaluate the volume irradiated with hadron beams and the deposited dose distribution in a patient's body. Several methods have been proposed for this purpose, one of which uses the positron emitters generated through fragmentation reactions between incident ions and target nuclei. In the previous paper, we showed that the maximum likelihood estimation (MLE) method could be applicable to the estimation of beam end-point from the measured positron emitting activity distribution for mono-energetic beam irradiations. In a practical treatment, a spread-out Bragg peak (SOBP) beam is used to achieve a uniform biological dose ...
2005-12-21
Energy Technology Data Exchange (ETDEWEB)
The distribution of carrier free lead-203 between plasma and cells of canine blood in vitro was measured. Activity in the plasma decreased to less than 5% of the initial blood activity during the first 15 min and then exponentially with a half time of 160 min. Incubation in cell free plasma before addition to whole blood transformed the isotope, decreasing the amount subsequently associated with cells. In animal studies, activity was measured in plasma, blood cells, urine, and feces after exposure to lead-203. In one group, the animals were exposed by intravenous injection of dilute citric acid solutions of isotope. In a second group, carrier free isotope which had been transformed by incubation in plasma was injected intravenously. The kinetics of the distribution of the isotope differed between the two experimental groups. After injection of the transformed lead, the lead-203 content of the blood cell fraction rose from 10% of the ...
1980-01-01
Therapeutic Applications of Monte Carlo Calculations in Nuclear Medicine
This book examines the applications of Monte Carlo (MC) calculations in therapeutic nuclear medicine, from basic principles to computer implementations of software packages and their applications in radiation dosimetry and treatment planning. It is written for nuclear medicine physicists and physicians as well as radiation oncologists, and can serve as a supplementary text for medical imaging, radiation dosimetry and nuclear engineering graduate courses in science, medical and engineering faculties. With chapters is written by recognised authorities in that particular field, the book covers the entire range of MC applications in therapeutic medical and health physics, from its use in imaging prior to therapy to dose distribution modelling targeted radiotherapy. The contributions discuss the fundamental concepts of radiation dosimetry, radiobiological aspects of targeted radionuclide therapy and the various components and steps required for ...
2003-01-01
British Library Electronic Table of Contents (United Kingdom)
Rapid administration of stable iodine is essential for the saturation and subsequent protection of the thyroid gland against the potential harm caused by radioiodines. This paper proposes the Dutch risk analysis that uses an atmospheric dispersion model to calculate the size of the zones around nuclear power plants where radiological thyroid doses for children might be sufficiently high to warrant iodine administration. Dose calculations for possible releases from the nuclear power plants of Borssele (The Netherlands), Doel (Belgium) and Emsland (Germany) are based on two scenarios in combination with a 1-y set of authentic, high-resolution meteorological data. The dimensions of the circular zones were defined for each nuclear power plant. In these zones, with a radius up to 50 km, distrib...
2010-01-01
Monte Carlo calculations using the codes PENELOPE and GEANT4 have been performed to characterize the dosimetric properties of monoenergetic photon point sources in water. The dose rate in water has been calculated for energies of interest in brachytherapy, ranging between 10 keV and 2 MeV. A comparison of the results obtained using the two codes with the available data calculated with other Monte Carlo codes is carried out. A chi2-like statistical test is proposed for these comparisons. PENELOPE and GEANT4 show a reasonable agreement for all energies analyzed and distances to the source larger than 1 cm. Significant differences are found at distances from the source up to 1 cm. A similar situation occurs between PENELOPE and EGS4.
2006-01-01
Energy Technology Data Exchange (ETDEWEB)
It is planned to use the tritium dose model, DCART (Doses from Chronic Atmospheric Releases of Tritium), to reconstruct dose to the hypothetical maximally exposed individual from annual routine releases of tritiated water (HTO) and tritiated hydrogen gas (HT) from all Lawrence Livermore National Laboratory (LLNL) facilities and from the Sandia National (SNL) Laboratory's Tritium Research Laboratory over the last fifty years. DCART has been described in Part 1 of ''Historical Doses From Tritiated Water And Tritiated Hydrogen Gas Released To The Atmosphere from Lawrence Livermore National Laboratory (LLNL)'' (UCRL-TR-205083). This report (Part 2) summarizes information about annual routine releases of tritium from LLNL (and SNL) since 1953. Historical records were used to derive facility-specific annual data (e.g., source terms, dilution factors, ambient air ...
2005-03-07
Growth and cell kinetic changes of HeLa S-3 spheroids following hyperfractionated irradiation
International Nuclear Information System (INIS)
Optimal design of the hyperfractionated radiotherapy requires basic radiobiological data such as the critical dose per fraction, number of fractions per day and total equivalent dose, to name a few. As a prelude to in vivo hyperfractionated irradiation, the authors carried out experiments to determine quantitative changes in the proliferation and cell kinetic parameters of multicellular spheroids after hyperfractionated irradiation. Experiments were carried out with HeLa S-3 spheroid growing in MEM culture media. Hyperfractionated irradiation schedules were 1.5 Gy/f, 2f/day and 1.0 Gy/f, 3 f/day. At intervals after irradiation, cell numbers, growth delays and cell cycle distribution of spheroids were determined. The kinetic data were obtained by the use of flow cytometry. The most pronounced changes in cell kinetic parameters were early G/sub 2/M block, proportional to single radiation dose up to 4.0 ...
International Nuclear Information System (INIS)
Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle"3 treatment planning system, and the dose was calculated in a water phantom. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as well as its spatial dosimetric characteristics. Results: Agreement within 5.0% was observed between the Pinnacle"3 predicted dose ...
2009-10-01
Depleted uranium human health risk assessment, Jefferson Proving Ground, Indiana
Energy Technology Data Exchange (ETDEWEB)
The risk to human health from fragments of depleted uranium (DU) at Jefferson Proving Ground (JPG) was estimated using two types of ecosystem pathway models. A steady-state, model of the JPG area was developed to examine the effects of DU in soils, water, and vegetation on deer that were hunted and consumed by humans. The RESRAD code was also used to estimate the effects of farming the impact area and consuming the products derived from the farm. The steady-state model showed that minimal doses to humans are expected from consumption of deer that inhabit the impact area. Median values for doses to humans range from about 1 mrem ({plus_minus}2.4) to 0.04 mrem ({plus_minus}0.13) and translate to less than 1 {times} 10{sup {minus}6} detriments (excess cancers) in the population. Monte Carlo simulation of the steady-state model was used to derive the probability distributions from which the median values were drawn. Sensitivity ...
1994-04-29
International Nuclear Information System (INIS)
The dithiocarbamate and thiuram compounds, including disulfiram, were compared for their efficacies in influencing tissue distribution of a trace dose of intravenously injected lead plus "2"0"3Pb in rats. The tested compounds were sodium diethyldithiocarbamate (DEDTC), sodium dimethyldithiocarbamate (DMDTC), tetraethylthiuram disulfide (disulfiram), a complex of zinc and manganese ethylenebisdithiocarbamate (mancozeb), manganese ethylenebisdithiocarbamate (maneb), sodium monomethyldithiocarbamate (metham), zinc propylene bisdithiocarbamate (propineb), tetramethylthiuram disulfide (thiram), zinc ethylenebisdithiocarbamate (zineb), and zinc dimethyldithiocarbamate (ziram). The results of this study show that interactions can occur between lead and DEDTC, DMDTC, disulfiram, metham, thiram, and ziram, resulting in increased levels of lead in brain and probably potentiation of the neurotoxic effects of lead.
International Nuclear Information System (INIS)
A study on the distribution of "1"3"7Cs in coastal waters up to a distance of 15 km was undertaken for a decade (1995-2004) and observed that the activity has reduced by 15-20 fold. Statistical and trend analysis was carried out to resolve the contribution of different facilities at a distance of 5 km (north and south) from the discharge point by log normal probability analysis and found that at 5 km south, the median value of "1"3"7Cs due to TAPS and FRP discharges were 3.7 mBq/l and 1.50 mBq/l respectively. The observed levels of "1"3"7Cs are of no consequences from the point of view of dose to members of the public. (author)
2005-11-23
Is energy imparted a good measure of the radiation risk associated with CT examinations
International Nuclear Information System (INIS)
The dose distribution in a Rando phantom has been measured for typical EMI 5005 CT scans of the head, chest, abdomen and pelvis. These dose distributions have been used to generate quantitative estimates of the somatic and genetic radiation risks associated with these CT examinations and also to measure the total energy imparted during each scan. A comparison has been made between the radiation risk estimates and the energy imparted measurements. The energy imparted measurements are not a good indicator of the somatic and/or genetic risks when one type of CT scan is compared with another. However, for a given type of scan, the energy imparted may be a reasonable indicator of the relative somatic risks associated with different CT examinations. Considerable care should be taken when interpreting and using any measured value of energy imparted in a radiological examination since published values of the ...
International Nuclear Information System (INIS)
Processing of food with ionizing radiation is a method suitable to enhance shelf-life and hygienic quality. Up to a dose of 10 kGy the method is considered wholesome. In many countries the practical use of food irradiation is increasing, however, in the Federal Republic of Germany the process is strictly forbidden. Applications and methods for radiation processing of food are compiled, limits and prospects are explained, and advantages and disadvantages are compared with traditional methods. Identification of irradiated foods and dosimetry and process control for radiation processing of food are areas where further research is needed. Continuous processing of particulate foods in bulk is an application where electron accelerators might be profitable. Beam parameters and velocity distribution of food particles in the treatment area can be matched for an effective result. Thus, dose distribution can be ...
Characterization of an add-on multileaf collimator for electron beam therapy
Energy Technology Data Exchange (ETDEWEB)
An add-on multileaf collimator for electrons (eMLC) has been developed that provides computer-controlled beam collimation and isocentric dose delivery. The design parameters result from the design study by Gauer et al (2006 Phys. Med. Biol. 51 5987-6003) and were configured such that a compact and light-weight eMLC with motorized leaves can be industrially manufactured and stably mounted on a conventional linear accelerator. In the present study, the efficiency of an initial computer-controlled prototype was examined according to the design goals and the performance of energy- and intensity-modulated treatment techniques. This study concentrates on the attachment and gantry stability as well as the dosimetric characteristics of central-axis and off-axis dose, field size dependence, collimator scatter, field abutment, radiation leakage and the setting of the accelerator jaws. To provide isocentric irradiation, the eMLC can be placed either 16 or ...
2008-02-21
International Nuclear Information System (INIS)
The main problems arising in decommissioning nuclear-powered submarines (NPS) relate to choosing a concept of handling reactor compartments followed by handling technology development. Reactor compartments (RC) are characterized with extremely space-saving or integral layout of large-size power equipment and systems, restricted access for dismantling, high radiation dose rates in a number of bays of RC. The above RC features pose a problem to find optimum option of RC utilization which on the one hand would be the most cost efficient, and the safest as possible on the other, i.e. dose commitments of personnel involved should be minimum, and effect on population and environment should be negligible. The main radiation factors specifying safety in RC handling at any decommissioning stage are as follows: (1) total radioactivity integrated in reactor facility (RF); (2) distribution of this radioactivity through RF equipment and ...
1996-03-10
Energy Technology Data Exchange (ETDEWEB)
The influence of high energy electron (23 MeV) irradiation on the electrical characteristics of p-channel polysilicon thin film transistors (PSTFTs) was studied. The channel 220 nm thick LPCVD (low pressure chemical vapor deposition) deposited polysilicon layer was phosphorus doped by ion implantation. A 45 nm thick, thermally grown, SiO{sub 2} layer served as gate dielectric. A self-alignment technology for boron doping of the source and drain regions was used. 200 nm thick polysilicon film was deposited as a gate electrode. The obtained p-channel PSTFTs were irradiated with different high energy electron doses. Leakage currents through the gate oxide and transfer characteristics of the transistors were measured. A software model describing the field enhancement and the non-uniform current distribution at textured polysilicon/oxide interface was developed. In order to assess the irradiation-stimulated changes of gate oxide parameters the gate ...
2006-08-15
International Nuclear Information System (INIS)
The influence of high energy electron (23 MeV) irradiation on the electrical characteristics of p-channel polysilicon thin film transistors (PSTFTs) was studied. The channel 220 nm thick LPCVD (low pressure chemical vapor deposition) deposited polysilicon layer was phosphorus doped by ion implantation. A 45 nm thick, thermally grown, SiO_2 layer served as gate dielectric. A self-alignment technology for boron doping of the source and drain regions was used. 200 nm thick polysilicon film was deposited as a gate electrode. The obtained p-channel PSTFTs were irradiated with different high energy electron doses. Leakage currents through the gate oxide and transfer characteristics of the transistors were measured. A software model describing the field enhancement and the non-uniform current distribution at textured polysilicon/oxide interface was developed. In order to assess the irradiation-stimulated changes of gate oxide parameters the gate oxide ...
2006-08-01
Dose, exposure time, and resolution in Serial X-ray Crystallography
The resolution of X-ray diffraction microscopy is limited by the maximum dose that can be delivered prior to sample damage. In the proposed Serial Crystallography method, the damage problem is addressed by distributing the total dose over many identical hydrated macromolecules running continuously in a single-file train across a continuous X-ray beam, and resolution is then limited only by the available molecular and X-ray fluxes and molecular alignment. Orientation of the diffracting molecules is achieved by laser alignment. We evaluate the incident X-ray fluence (energy/area) required to obtain a given resolution from (1) an analytical model, giving the count rate at the maximum scattering angle for a model protein, (2) explicit simulation of diffraction patterns for a GroEL-GroES protein complex, and (3) the frequency cut off of the transfer function following iterative solution of the phase problem, and reconstruction ...
2007-01-01
An evaluation of the pendulum technique of electron beam therapy
International Nuclear Information System (INIS)
Electron beam therapy of lesions such as cutaneous metastatic carcinoma and reticulum cell sarcoma is performed via multiple portals for a wide irradiation field. However, the dose distribution in border areas is generally uneven, resulting in hot and cold dose areas depending on the intervals of the portals. We performed electron irradiation by the pendulum technique, especially on curved areas, and evaluated the technique in various respects. Pendulum electron beam irradiation is indicated when the length of the cone must be reduced in order to deliver the target volume near the skin surface as well as to avoid the occurrence of hot spots deep in the body. We prepared a 15cm rotating cone by cutting a 30cm fixed irradiation cone. The modification posed no disadvantages in terms of extent and flatness of the beam, or stability during rotation. After determining the relationship between the rotation speed and the ...
Synthesis and tissue distribution study of iodine-labeled benzyl- and xylylamines
Energy Technology Data Exchange (ETDEWEB)
Four /sup 125/I labeled mono- and diamines were prepared and evaluated as potential brain-imaging agents. The diamines are analogues of the previously reported /sup 75/Se labeled diamines, which show high brain uptake and retention. All of the radioiodinated amines display high initial brain uptake in rats after intravenous injection (1.7-2.4% dose/organ). The xylylenediamines show prolonged brain retention (t1/2 approximately 18 h), which is desirable for brain imaging. In contrast, the benzylamine is rapidly cleared from brain tissue (t1/2 approximately 15 min).
1982-07-01
Energy Technology Data Exchange (ETDEWEB)
The bibliography contains citations concerning plasma immersion ion implantation (PIII) and equipment. PIII is a new technique to implant plasma ions into materials for surface modification and treatment. Topics include plasma nitriding, semiconductor doping, ion energy distribution, ion dose, pulsed plasma, metal plasma, and defect passivation. References also review applications in semiconductor device and integrated circuit manufacture, silicon material fabrication, aerospace bearings, carbon coatings on metals, and ceramic coatings. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)
1998-01-01
International Nuclear Information System (INIS)
A quantitative comparison of tissue distribution and excretion of an orally administered sublethal dose of [3H]diacetoxyscirpenol (anguidine) was made in rats and mice 90 min, 24 hr, and 7 days after treatment. Total recoveries of 95-100% were obtained. Approximately 90% of the dose was excreted in urine and feces during the first 24 hr with a feces:urine ratio of about 1:4.5 in both species. Carcass and tissue radioactivity dropped rapidly during the first 24 hr but remained relatively constant at low, but detectable, levels over the course of the experiment. Few substantive interspecies differences were noted in tissue distribution. At 90 min the highest percentage of dose was in tissues involved in sequestering diacetoxyscirpenol because of high body water/lipid content or the absorption, metabolism, or excretion of the toxin. The rank order of these tissues was generally stable ...
International Nuclear Information System (INIS)
Track analysis of medium energy #alpha# particle trajectories recorded in fine grain nuclear emulsion submitted to specific intensifying treatments led to the observation of strong ionizing events (SIE) sticking out of the primary's track core. Preliminary determinations showed that the number of SIEs increases with the primary's energy, and that their production is of more than one order of magnitude higher than the number of Rutherford recoils. The presence of SIEs on monoenergetic #alpha# tracks also has a significant influence on the measured range distribution, which, expressed in terms of energy loss, results in a mean contribution to the total energy loss of far reaching (SIEs (radial spread >= 0.458 #mu#m) of proportional 25 keV per 13.6 MeV #alpha# particle, instead of 0.75 keV in the case where only the Rutherford interactions are taken into account. Measurements carried out in detectors enriched with gelatin indicate an increase ...
Monte Carlo simulation and dosimetric verification of radiotherapy beam modifiers
International Nuclear Information System (INIS)
Monte Carlo simulation of beam modifiers such as physical wedges and compensating filters has been performed with a rectilinear voxel geometry module. A modified version of the EGS4/DOSXYZ code has been developed for this purpose. The new implementations have been validated against the BEAM Monte Carlo code using its standard component modules (CMs) in several geometrical conditions. No significant disagreements were found within the statistical errors of 0.5% for photons and 2% for electrons. The clinical applicability and flexibility of the new version of the code has been assessed through an extensive verification versus dosimetric data. Both Varian multi-leaf collimator (MLC) wedges and standard wedges have been simulated and compared against experiments for 6 MV photon beams and different field sizes. Good agreement was found between calculated and measured depth doses and lateral dose profiles along both wedged and unwedged directions for ...
2001-11-01
International Nuclear Information System (INIS)
7,959 patients were examined by radionuclide in-vivo methods within one year, 1,228 of them by application of "1"3"1I-iodide (radioiodine test and scintigraphy of the thyroid gland). In compliance with the ICRP publications 26 and 27 the somatically effective equivalent dose H/sub s,eff/ was ascertained for several examining methods, derived from it the collective dose S/sub s,eff/ and considering a part of manifestation resulting from the age distribution of patients, the somatic risk regarding radiation-induced malignoma with fatal termination. For the patients examined by "1"3"1I-iodide the collective dose was 79.9 man x Sv and the mean somatic risk 30 x 10"-"5 with a part of manifestation of 0.39 accordig to 0.37 radiation-induced malignomas with fatal termination. For all patients examined by other radiopharmaceuticals the collective dose was 14.07 man x Sv, the mean somatic ...
1986-01-01
A deterministic partial differential equation model for dose calculation in electron radiotherapy
International Nuclear Information System (INIS)
High-energy ionizing radiation is a prominent modality for the treatment of many cancers. The approaches to electron dose calculation can be categorized into semi-empirical models (e.g. Fermi-Eyges, convolution-superposition) and probabilistic methods (e.g. Monte Carlo). A third approach to dose calculation has only recently attracted attention in the medical physics community. This approach is based on the deterministic kinetic equations of radiative transfer. We derive a macroscopic partial differential equation model for electron transport in tissue. This model involves an angular closure in the phase space. It is exact for the free streaming and the isotropic regime. We solve it numerically by a newly developed HLLC scheme based on Berthon et al (2007 J. Sci. Comput. 31 347-89) that exactly preserves the key properties of the analytical solution on the discrete level. We discuss several test cases taken from the medical physics literature. ...
2010-07-07
Comparison of beam-induced deposition using ion microprobe
International Nuclear Information System (INIS)
The localized Pt deposition on Si by 30 keV Ga"+ focused ion beam (FIB), 10 keV electron beam (EB) or dual beams (FIB and EB) using precursor gas has been compared by analysis using a 300 keV Be"2"+ microprobe with a beam spot size of 80 nm. The distribution of deposited Pt, Ga from the ion beam itself, and C from the precursor gas was obtained at and nearby the deposited areas by micro-RBS spectra and RBS mapping. All of the beam processed areas showed a uniform Pt distribution at the deposited areas. The amount of Pt atoms increased with the increase in ion or electron dose due to the decomposition of precursor gas. The thickness of Pt layer by EB is considerably less than that by FIB due to the reduced deposition rate. Ga atoms from the center of processed areas partly redeposited at and nearby the FIB processed areas within #approx#3 #mu#m. The Ga incorporation by dual beam processing was reduced compared with that by ...
1999-01-02
International Nuclear Information System (INIS)
This report is devoted to the investigation of the influence of electron collisions and radial non-uniformity of plasma density on phase characteristics, spatial attenuation and wave field structure of slow symmetric electromagnetic waves that propagate along cylindrical waveguide structure. It has been shown that collision rate and radial non-uniformity of plasma density for various parameters of waveguide structure and dielectric affect essentially on the wave characteristics and consequently, on the parameters of gas discharge that is sustained by this wave. The results obtained are of large importance for the construction of the theory of gas discharges that are sustained by the surface electromagnetic waves.
2006-01-01
Orbit of the double-mode cepheid Y Carinae
Energy Technology Data Exchange (ETDEWEB)
The double-mode cepheid Y Car has been found to have a variable centre-of-mass velocity. Though the observations did not cover a cycle, an orbital period of about 400-600 days was estimated. Radial-velocity observations of this star have now been continued in order to derive the orbital elements. Observations were made with the photoelectric radial-velocity spectrophotometer at the coude focus of the 1.88-m reflector at Sutherland. The velocity system was standardized by frequent nightly observations of stars in the Mount Wilson catalogue with 'a'-quality radial velocities.
1983-06-01
Geometry changes transient transport in plasmas
Energy Technology Data Exchange (ETDEWEB)
Role of ballooning effect in toroidal plasmas on the transient transport problems is investigated. Due to the mode localization along the magnetic field line, a meso scale appears in a radial correlation length of fluctuating fields. This scale length introduces the interference of the gradient and flux in different radial locations. For the fluctuation which gives the gyro-Bohm-like diffusion in a stationary state, this long radial correlation of the fluctuating field causes a fast propagation of response against a rapid transient perturbation. Upper bound of transient thermal diffusivity is derived. (author)
2001-06-01
Concepts of radiotherapy treatment planning
International Nuclear Information System (INIS)
Full text: Radiotherapy treatment planning (RTP) relies heavily on medical imaging. Until recently, the most important planning tool was the treatment simulator. The kilovoltage radiographic capabilities in a treatment simulator enabled the boundaries of treatment fields to be visualized with respect to bony anatomic landmarks. Perhaps the most important advance in treatment planning in recent years is the ability to visualize the passage of the beams with respect to a more accurate geometrical representation of the tumor and other soft tissue structures. This 'virtual simulation' uses a computer-based representation of a patient to determine the extent of the disease and the location of radiation sensitive normal tissue. Computer tomographic (CT) imaging produces a high-resolution three-dimensional representation of anatomy that can be correlated with other image sets such as magnetic resonance images (MRI) of function. Positron emission tomographic (PET) imaging is beginning to be ...
2000-12-01
Semi Annual Progress Report on BLADE END WALL FLOWS IN COMPRESSORS ...
Eckert, B., "Axial Kompressoren und Radial Kompressoren," Springer. Verlag, Berlin, 1953. 3. Lebot, Y., et al., "Theoretical and Experimental Determination ...
Energy Technology Data Exchange (ETDEWEB)
The present emphasis on inherent safety for LMR designs has resulted in a need to represent the various reactivity feedback mechanisms as accurately as possible. The dominant negative reactivity feedback has been found to result from radial expansion of the core for most postulated ATWS events. For this reason, a more detailed model for calculating the reactivity feedback from radial core expansion has been recently developed for use with the SASSYS/SAS4A Code System. The purpose of this summary is to present an extension to the model so that it is more suitable for handling a core restraint design as used in FFTF, and to compare the SASSYS/SAS4A results using this model to the empirical correlation presently being used to account for radial core expansion reactivity feedback to FFTF.
1987-01-01
Energy Technology Data Exchange (ETDEWEB)
In this work a study of simulation of the gamma graphic studies that are carried out in human esophagus in the Dept. of Nuclear Medicine of the 'Celestino Hernandez Robau Hospital of Santa Clara is presented. For the investigation tubular reactors were used and sting-response techniques with radioactive tracer of Technetium 99 metastable to a concentration of 1 mCi and several flows were applied. The distribution curves of residences times were obtained, those that respond to an equation of the type: Y = A + B exp (- exp((x-C)/D)) - ((x-C/D)+1). They were also carried out, optimizations studies of the doses of the radioactive to give to the patients from 1 mCi (that is the one used in studies) up to 0,5 mCi, and the influences on the obtained distributions of residence time were analyzed. It was confirmed the possibility to lower the doses with clear information of the signal. It was also ...
2003-07-01
International Nuclear Information System (INIS)
The focus of this study is to validate whether the sensitivity of dose distribution following the interface of different media can be used to distinguish between small variations of photon energy spectra in the context of the convolution/superposition algorithm in the polyenergetic implementation (Philips Pinnacle"3, ADAC Laboratories, Milpitas, CA). Calculations were performed in homogeneous water and heterogeneous lung/water phantoms. Spectra were generated, in which the weights of the low-, medium- and high-energy components were adjusted sequentially. The heterogeneity correction factor CF_l_u_n_g, the D_2_0/D_1_0 ratio for homogeneous water and logarithmic derivative in buildup region LD_b_u_i_l_d_u_p were assessed for their relative ability to discriminate between different spectra for various field sizes. In accordance with another study (Charland et al 2004), the superior discrimination ability of the CF_l_u_n_g and LD_b_u_i_l_d_u_p ...
2004-09-21
Application of dose factors for decay chains
International Nuclear Information System (INIS)
... dose rates inhalation iodine 134 krypton 88 nuclear decay quality factor
Medical consequences of radiation accidents
International Nuclear Information System (INIS)
Since 1945, more than 1.8 x 10"2"1 Bq of artificial radionuclides have been released into the atmosphere. Approximately 2.04 x 10"1"8B, i.e. approx. 0.11%, are the result of accidents at nuclear industrial facilities. This percentage is causing increased interest among researchers. This is due to the fact that in the wake of accidental release radionuclides become distributed unevenly across the Earth's surface, and the associated exposures, fluctuating from background level to several grays, an induce both stochastic and deterministic effects in the irradiated population. A comparative analysis of the medical consequences of the twentieth century's most serious nuclear events, namely the authorized dumping of high level radioactive waste into the river Techa in 1950, the explosion of a storage tank containing long lived radioactive waste in the Southern Urals in 1957, the fire at Sellafield in 1957 and the accident at the Chernobyl nuclear power plant in 1986, has ...
1995-10-01
Disposal of old heads for Daya Bay NPP
International Nuclear Information System (INIS)
The paper introduces the disposal procedures of the old reactor pressure vessel head. Reactor pressure vessel (RPV) heads were replaced successfully in Daya Bay Nuclear Power Plant. The on-site treatment and disposal of replaced heads was thereafter implemented. This is the first time in China for large size radioactive article disposal. To guarantee the safety of old head treatment, issues of radiation protection have to be taken into account. Dose rate distribution of the old head surface and radioactivity were initially calculated according to the operation history and the neutron flux rate of the reactor. Shielding calculation and package design was thereafter worked out based on the data obtained from the old head, e.g. neutron flux, sorts of nuclides, radioactivity and dose rates. Shielding package was afterwards manufactured in special factories and transported to Daya Bay NPP site by truck and ship. The shielding ...
Development of an irradiation system for a small size continuous run multipurpose gamma irradiator
International Nuclear Information System (INIS)
The Radiation Technology Center from IPEN-CNEN/SP, Brazil, developed a revolutionary design and national technology, a small-sized continuous run and multipurpose industrial gamma irradiator, to be used as a demonstration facility for manufacturers and contract service companies, which need economical and logistical in-house irradiation system alternatives. Also, to be useful for supporting the local scientific community on development of products and process using gamma radiation, assisting the traditional and potential users on process validation, training and qualification of operators and radioprotection officers. The developed technology for this facility consists of a continuous tote box transport system, comprising a single concrete vault, where the automated transport system of products inside and outside of the irradiator utilizes a rotating door, integrated with the shielding, avoiding the traditional maze configuration. Covering 76 m"2 of floor area, the irradiator design is ...
Energy Technology Data Exchange (ETDEWEB)
A formula for calculating the Dirac S-matrix for central Lorentz scalar and vector potentials is derived by use of a new amplitude-phase method. The derivation also makes use of certain invariants of the reduced 2-spinor radial Dirac equations.
2008-12-15
International Nuclear Information System (INIS)
A formula for calculating the Dirac S-matrix for central Lorentz scalar and vector potentials is derived by use of a new amplitude-phase method. The derivation also makes use of certain invariants of the reduced 2-spinor radial Dirac equations.
2008-12-01
International Nuclear Information System (INIS)
At Tarapur Atomic Power Station 3 and 4, 540 MWe Pressurised Heavy Water Reactors, core being large in size requires a continuous in core monitoring for local flux disturbances. Nearly 200 Self Powered Neutron Detectors (SPNDs) of the Straight Individually Replaceable (SIR) type are distributed in the reactor core. For purpose of reactor regulation and protection, cobalt SPNDs that have a prompt response for changes in power is used for in-core flux mapping, vanadium SPNDs that provide accurate measure of neutron flux, even though having slow response is used In core SPNDs are placed in Vertical Flux Units (VFU) and Horizontal Flux Units (HFUs). These SPNDs were to be replaced at regular intervals to meet the design intent. Cobalt SPNDs have dose rates of the order of 1000 Gy/h and the Mineral Insulated (MI) cables of Vanadium SPNDs have dose rates of the order of 100 Gy/h. So far 3 Cobalt SPNDs were removed from HFUs and ...
2006-11-13
Natural radionuclides in drinking water in Argentina
International Nuclear Information System (INIS)
As part of the national survey to evaluate natural radioactivity in the environment, concentration levels of natural uranium and "2"2"6Ra have been analyzed in over 300 drinking water samples taken from different locations in Argentina. "2"2"6Ra was determined by "2"2"2Rn emanation and liquid scintillation counting, and natural uranium by a fluorimetric procedure. Values ranging from 0.03 to 24 #mu#g.l"-"1 of natural uranium and from 0.06 to 50 #mu#g.l"-"1, were measured on drinking water samples taken from tap water systems and private wells, respectively. Concentrations up to 15 mBq.l"-"1 and to 22 mBq.l"-"1 of "2"2"6Ra were found in drinking water samples taken from tap water systems and private wells, respectively. These values are compared with the reference values accepted for drinking water. Based on the water intake rate, the age distribution and the measured concentrations, an annual collective effective dose of 1.9 man Sv and an ...
2000-05-01
Energy Technology Data Exchange (ETDEWEB)
Graft copolymerization of sodium styrene sulfonate (SSS) onto electron beam (EB) irradiated poly(vinylidene fluoride) (PVDF) films was investigated to find out a simple preparation process for sulfonic acid proton exchange membranes with respect to monomer concentration, absorbed dose, temperature, film thickness and storage time. The reaction order of the monomer concentration and absorbed dose of grafting was found to be 2.84 and 1.20, respectively. The overall activation energy for graft copolymerization reaction was calculated to be 11.36 kJ/mol. The initial rate of grafting was found to decrease with an increase in the film thickness. The trapped radicals in the irradiated PVDF films remained effective in initiating the reaction without considerable loss in grafting level up to 180 days, when stored under -60 {sup o}C. The presence and distribution of polystyrene sulfonate grafts in the obtained membranes were observed ...
2011-01-15
Environmental impact assessment around TRIGA research reactor
International Nuclear Information System (INIS)
Population distribution, atmospheric change, X/Q, characteristics of terrestrial ecosystem around Seoul site were surveyed. Environmental radiation and radioactivities such as gross#alpha#, gross#beta#, Cs-137, Sr-90 and H-3 of various environmental samples were analyzed. The values of environmental radiation dose tended to increase gradually in the light of the recent five years' results of environmental radiation monitoring around the nuclear power plants from 1980 to 1984, however, the changes were not significant. In addition, continuous assessment of environmental radiation monitoring on the roofs of main building and life science building at KAERI showed that the environmental radiation dose tended to increase a little during the night time. Judging from the above results, it is concluded that environmental contamination level by radioactive materials could be ignored in the case of radioisotope production or ...
1985-04-01
Depth dependence of defect evolution and TED during annealing
Energy Technology Data Exchange (ETDEWEB)
A quantitative transmission electron microscopy (TEM) study on the depth profile of extended defects, formed after Si implantation, has been carried out. Two different Si{sup +} implant conditions have been considered. TEM analysis for the highest energy/dose shows that {l_brace}1 1 3{r_brace} defects evolve into dislocation loops whilst the defect depth distribution remains unchanged as a function of annealing time. For the lowest energy/dose, {l_brace}1 1 3{r_brace} defects grow and dissolve while the defect band shrinks preferentially on the surface side. At the same time, extraction of boron transient enhanced diffusion (TED) as a function of depth shows a decrease of the supersaturation towards the surface, starting at the location of the defect band. The study clearly shows that in these systems the silicon surface is the principal sink for interstitials. The results provide a critical test of the ability of physical ...
2004-02-01
Depth dependence of defect evolution and TED during annealing
International Nuclear Information System (INIS)
A quantitative transmission electron microscopy (TEM) study on the depth profile of extended defects, formed after Si implantation, has been carried out. Two different Si"+ implant conditions have been considered. TEM analysis for the highest energy/dose shows that #left brace#1 1 3#right brace# defects evolve into dislocation loops whilst the defect depth distribution remains unchanged as a function of annealing time. For the lowest energy/dose, #left brace#1 1 3#right brace# defects grow and dissolve while the defect band shrinks preferentially on the surface side. At the same time, extraction of boron transient enhanced diffusion (TED) as a function of depth shows a decrease of the supersaturation towards the surface, starting at the location of the defect band. The study clearly shows that in these systems the silicon surface is the principal sink for interstitials. The results provide a critical test of the ability of ...
2004-02-01
Thermal Hydraulics Analysis for the 3MW TRIGA MARK-II Research Reactor Under Transient Condition
International Nuclear Information System (INIS)
Some important thermal hydraulic parameters of the 3 MW TRIGA MARK-II research reactor operating under transient condition were investigated using two computer codes PULTRI and TEMPUL. Major transient parameters, such as, peak power and prompt energy released after pulse, maximum fuel and coolant temperature, surface heat flux, time and radial distribution of temperature within fuel element after pulse, fuel, fuel-cladding gap width variation, etc. were computer and compared with the experimental and operational values as reported in the safety Analysis Report (SAR). It was observed that pulsing of the reactor inserting an excess reactivity of $2.00 shoots the reactor power level to 854.353 MW compared to an experimental value of 852 MW; the maximum fuel temperature corresponding to this peak power was found to be 846.76"o C which is much less than the limiting maximum value of fuel temperature of 1150"0 C as reported in SAR. During a pulse if ...
1985-07-01
TRIGA spent fuel bundles safe storage
International Nuclear Information System (INIS)
TRIGA-SSR is a steady state research and material test reactor that has been in operation since 1980. The original TRIGA fuel was HEU (highly enriched uranium) with a U"2"3"5 enrichment of 93 per cent. Almost all TRIGA HEU fuel bundles are now burned-up. Part of the spent fuel was loaded and transferred to US, in a Romania - DOE arrangement. The rest of the TRIGA fuel bundles have to be temporarily stored in the TRIGA facility. As the storage conditions had to be established with caution, neutron and thermal hydraulic evaluations of the storage conditions were required. Some criticality evaluations were made based on the SAR (Safety Analysis Report) data. Fuel constant axial temperature approximation effect is usual for criticality computations. TRIGA-SSR fuel bundle geometry and materials model for SCALE5-CSAS module allows the introduction of a fuel temperature dependency for the entire fuel active height, using different materials for each fuel bundle region. Previous RELAP5 thermal ...
2007-05-13
Suspension and solution plasma spraying of finely structured layers: potential application to SOFCs
International Nuclear Information System (INIS)
Suspension direct current plasma spraying allows achieving finely structured coatings whose thickness is between few tens and few hundreds of micrometres. Drops (200-300 ?m in diameter) or liquid jets are mechanically injected in the plasma jet. With radial injection they are rapidly (a few ?s) fragmented into droplets (a few ?m in diameter). The latter are vaporized (in a few ?s) and the solid particles contained in suspension droplets are accelerated and melted by the plasma jet. As in conventional plasma spraying (CPS), much smaller splats (with diameters between 0.2 and 3 ?m and thicknesses between 30 and 200 nm) are arranged in layers up to form the coating. The low inertia of particles requires spray distances between 40 and 60 mm which induces plasma heat fluxes up to 22 MW m-2 participating in coating densification. Even more than in CPS, the plasma jet fluctuations, particularly for plasmas containing di-atomic gases, perturb drops penetration and ...
2007-04-21
Simulation of natural convection cooling phenomena for research reactors using the code PARET
International Nuclear Information System (INIS)
This study deals with testing the capability of the code PARET to simulate natural convection cooling phenomena under different boundary conditions. In addition to applying and testing some new options related to simulation of the control rod movement and studying the reactivity effect of thermal expansion fuel elements. The experiments of the simple thermal hydraulic loop of Missouri university about natural cooling phenomena in two narrow paralled channels were used to validate the code. The study indicate good results regarding the distribution of coolant flux velocity and clad temperature. In particular the heat transfer coefficient of natural convection has been calculated in good agreement with the experiment. On the other hand, the core of MNSR reactor has been modelled to simulate the reactor dynamic behaviour under natural convection cooling conditions for different initial power level. The observed oscillation during the initial phase vanishes gradually ...
Rotation of the bulge components of barred galaxies
International Nuclear Information System (INIS)
Stellar rotation and velocity-dispersion measurements are presented for the bulge components of the SBO galaxies NGC 1023, 2859, 2950, 4340, 4371, and 7743. The kinematics of nine SB bulges with data available are compared with bulges of unbarred galaxies studied by Kormendy and Illingworth. All of the SB bulges are found to rotate at least as rapidly as oblate-spheroid dynamical models which are flattened by rotation. This result confirms the conclusion of Kormendy and Illingworth that bulges rotate very rapidly. Six SB bulges found by Kormendy and Koo to be triaxial rotate even more rapidly than the oblate models. In this respect, they resemble published n-body models of bars. That is, triaxial bulges are dynamically like bars and unlike elliptical galaxies, which are also believed to be triaxial, but which rotate slowly. Measured velocity anisotropies are found to be consistent with these conclusions. Two ordinary bulges whose rotation is well described by isotropic modes have a ...
Liquid Water from First Principles: Validation of Different Sampling Approaches
Energy Technology Data Exchange (ETDEWEB)
A series of first principles molecular dynamics and Monte Carlo simulations were carried out for liquid water to assess the validity and reproducibility of different sampling approaches. These simulations include Car-Parrinello molecular dynamics simulations using the program CPMD with different values of the fictitious electron mass in the microcanonical and canonical ensembles, Born-Oppenheimer molecular dynamics using the programs CPMD and CP2K in the microcanonical ensemble, and Metropolis Monte Carlo using CP2K in the canonical ensemble. With the exception of one simulation for 128 water molecules, all other simulations were carried out for systems consisting of 64 molecules. It is found that the structural and thermodynamic properties of these simulations are in excellent agreement with each other as long as adiabatic sampling is maintained in the Car-Parrinello molecular dynamics simulations either by choosing a sufficiently small fictitious mass in the microcanonical ensemble ...
2004-05-20
Energy Technology Data Exchange (ETDEWEB)
Palmitic acid (PA, 59.8 {sup o}C) and lauric acid (LA, 42.6 {sup o}C) are phase change materials (PCM) having quite high melting temperatures which can limit their use in low temperature solar applications such as solar space heating and greenhouse heating. However, their melting temperatures can be tailored to appropriate value by preparing a eutectic mixture of the lauric and the palmitic acids. In the present study, the thermal analysis based on differential scanning calorimetry (DSC) technique shows that the mixture of 69.0 wt% LA and 31 wt% PA forms a eutectic mixture having melting temperature of 35.2 {sup o}C and the latent heat of fusion of 166.3 J g{sup -1}. This study also considers the experimental determination of the thermal characteristics of the eutectic mixture during the heat charging and discharging processes. Radial and axial temperature distribution, heat transfer coefficient between the heat transfer fluid (HTF) pipe and ...
2005-04-01
Dynamic-stiffness matrix of embedded and pile foundations by indirect boundary-element method
Energy Technology Data Exchange (ETDEWEB)
The boundary-integral equation method is well suited for the calculation of the dynamic-stiffness matrix of foundations embedded in a layered visco-elastic halfspace (or a transmitting boundary of arbitrary shape), which represents an unbounded domain. It also allows pile groups to be analyzed, taking pile-soil-pile interaction into account. The discretization of this boundary-element method is restricted to the structure-soil interface. All trial functions satisfy exactly the field equations and the radiation condition at infinity. In the indirect boundary-element method distributed source loads of initially unknown intensities act on a source line located in the excavated part of the soil and are determined such that the prescribed boundary conditions on the structure-soil interface are satisfied in an average sense. In the two-dimensional case the variables are expanded in a Fourier integral in the wave number domain, while in three dimensions, Fourier series in ...
1984-08-01
Computational fluid dynamic analysis of core bypass flow phenomena in a prismatic VHTR
International Nuclear Information System (INIS)
The core bypass flow in a prismatic very high temperature reactor (VHTR) is an important design consideration and can have considerable impact on the condition of reactor core internals including fuels. The interstitial gaps are an inherent presence in the reactor core because of tolerances in manufacturing the blocks and the inexact nature of their installation. Furthermore, the geometry of the graphite blocks changes over the lifetime of the reactor because of thermal expansion and irradiation damage. The occurrence of hot spots in the core and lower plenum and hot streaking in the lower plenum (regions of very hot gas flow) are affected by bypass flow. In the present study, three-dimensional computational fluid dynamic (CFD) calculations of a typical prismatic VHTR are conducted to better understand bypass flow phenomena and establish an evaluation method for the reactor core using the commercial CFD code FLUENT. Parametric calculations changing several factors in a one-twelfth ...
2010-09-01
Computational Fluid Dynamic Analysis of Core Bypass Flow Phenomena in a Prismatic VHTR
Energy Technology Data Exchange (ETDEWEB)
The core bypass flow in a prismatic very high temperature gas-cooled reactor (VHTR) is one of the important design considerations which impacts considerably on the integrity of reactor core internals including operating fuels. The interstitial gaps are an inherent presence in the reactor core because of tolerances in manufacturing the blocks and the inexact nature of their installation. Furthermore, the geometry of the graphite blocks changes over the lifetime of the reactor because of thermal expansion and irradiation damage. The occurrence of hot spots in the core and lower plenum and hot streaking in the lower plenum (regions of very hot gas flow) will be affected by the bypass flow. In the present study, three-dimensional computational fluid dynamic (CFD) calculations of a typical prismatic VHTR are conducted to understand better the bypass flow phenomenon and establish the evaluation method in the reactor core using commercial CFD code FLUENT. Parametric calculations changing ...
2010-09-01
International Nuclear Information System (INIS)
In the report the results of the estimations of radiological risk of various stages of decommissioning of nuclear submarines are presented. At occurrence on nuclear submarine the heavy failure, relating to the class hypotetical volume of acting of radionuclides in atmosphere can reach 1.6E(15) Bq. Results of estimations probable doses on an axis of a trace of a radioactive loop show, that at distribution of radionuclides during atmospheric carry to 'agreed' settlement (500-1000 m) the maximum doses on its territory can make: about 6.0E(-3) Sv (for the whole body); 3.0E(-3) Gy for the leather (basal layer); 6.3E(-2) Gy for the lungs (acute exposure) and up to 1.8 Gy for the thyroid gland. Hypotetical failure for the estimation of the greatest possible radioecological consequences for hydrobiocenosis is considering, connected with single discharge of liquid radioactive waste (LRW) in water area. At navigating failure of the ...
2000-05-01
Energy Technology Data Exchange (ETDEWEB)
Iodized oil has been used as a contrast agent in lymphangiography. One of the commercially available compounds is Lipidol Ultra-fluid(LUF) which contains 38% iodine by weight. Nakakuma et al(1979) reported that LUF was selectively retained in the hypervascular hepatocellular carcinoma when injected directly into the ligated hepatic artery. Since that time, it has been widely utilized in the detection as well as the therapeutic attempts of hepatocellular carcinoma, where it has been mixed with chemotherapeutic agents or labeled with radioactive I-131. Like all significant advances, the mechanism of lipid retention within the hepatocellular carcinoma is not clearly understood, and also there is a lack of information about the biodistribution and kinetics of I-131 Lipiodol. The apparent safety of this technique require confirmation. The present study was aimed to assess the biodistribution and kinetics of intraarterially injected I-131 Lipiodol and the histologic changes in canine livers. ...
1989-08-15
The Preliminary GAMMA Code Thermal hydraulic Analysis for the Steady State of HTR-10 Initial Core
Energy Technology Data Exchange (ETDEWEB)
This report describes the preliminary thermalhydraulic analysis of HTR-10 steady state full power initial core to provide a benchmark calculation of VHTGR(Very High-Temperature Gas-Cooled Reactors) safety analysis code of GAMMA(GAs Multicomponent Mixture Analysis). The input data of GAMMA code are produced for the models of fluid block, wall block, radiation heat transfer and each component material properties in HTR-10 reactor. The temperature and flow distributions of HTR-10 steady state 10 MW{sub th} full power initial core are calculated by GAMMA code with boundary conditions of total reactor inlet flow rate of 4.32 kg/s, inlet temperature of 250 .deg. C, inlet pressure of 3 MPa, outlet pressure of 2.992 MPa and the fixed temperature at RCCS water cooling tube of 50 .deg C. The calculation results are compared with the measured solid material temperatures at 22 fixed instrumentation positions in HTR-10. The wall temperature distribution in ...
2006-07-15
Theoretical considerations for X-ray phase contrast mammography by Thomson source
Energy Technology Data Exchange (ETDEWEB)
The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase imaging with respect to standard absorption imaging, in the ...
2009-09-01
Synthesis and tissue distribution study of iodine-labeled benzyl- and xylylamines
International Nuclear Information System (INIS)
Four "1"2"5I labeled mono- and diamines were prepared and evaluated as potential brain-imaging agents. The diamines are analogues of the previously reported "7"5Se labeled diamines, which show high brain uptake and retention. All of the radioiodinated amines display high initial brain uptake in rats after intravenous injection (1.7-2.4% dose/organ). The xylylenediamines show prolonged brain retention (t1/2 approximately 18 h), which is desirable for brain imaging. In contrast, the benzylamine is rapidly cleared from brain tissue (t1/2 approximately 15 min).
Energy Technology Data Exchange (ETDEWEB)
RESRAD was one of the multimedia models selected by the US Nuclear Regulatory Commission (NRC) to include in its workshop on radiation dose modeling and demonstration of compliance with the radiological criteria for license termination. This paper is a summary of the presentation made at the workshop and focuses on the 10 questions the NRC distributed to all participants prior to the workshop. The code selection criteria, which were solicited by the NRC, for demonstrating compliance with the license termination rule are also included. Among the RESRAD family of codes, RESRAD and RESRAD-BUILD are designed for evaluating radiological contamination in soils and in buildings. Many documents have been published to support the use of these codes. This paper focuses on these two codes. The pathways considered, the databases and parameters used, quality control and quality assurance, benchmarking, verification and validation of these codes, and ...
1998-05-01
Neutron and gamma-ray penetrations in thick iron
Energy Technology Data Exchange (ETDEWEB)
Measurements of neutron and gamma-ray penetrations in an iron shield were performed up to a 60-cm depth in a tightly coupled source shield configuration with the fast-neutron reactor YAYOI as a source. Rates of neutron reactions and gamma-ray dose rates in the iron shield were obtained using activation foils and thermoluminescent dosimeters. Analyses of the experiments were made by using the DOT-III code with coupled neutron and gamma-ray cross sections from ENDF/B-IV and POPOP4 libraries. To obtain the source condition for the iron shield analyses, the calculated spectrum was adjusted to the measured reaction rates at the reactor shield boundary. The calculated neutron and gamma-ray distributions in the iron shield show fairly good agreement with the experiments. The effect of difference in Bondarenko-type self-shielding factors on the analyses of the iron shield is also shown.
1980-03-01
MCNP study for epithermal neutron irradiation of an isolated liver at the Finnish BNCT facility
International Nuclear Information System (INIS)
A successful boron neutron capture treatment (BNCT) of a patient with multiple liver metastases has been first given in Italy, by placing the removed organ into the thermal neutron column of the Triga research reactor of the University of Pavia. In Finland, FiR 1 Triga reactor with an epithermal neutron beam well suited for BNCT has been extensively used to irradiate patients with brain tumors such as glioblastoma and recently also head and neck tumors. In this work we have studied by MCNP Monte Carlo simulations, whether it would be beneficial to treat an isolated liver with epithermal neutrons instead of thermal ones. The results show, that the epithermal field penetrates deeper into the liver and creates a build-up distribution of the boron dose. Our results strongly encourage further studying of irradiation arrangement of an isolated liver with epithermal neutron fields.
2004-11-01
A TLD powder dosimetry measurement system for physical models of reference man
International Nuclear Information System (INIS)
A tissue-equivalent dosimetry system has been developed for use in absorbed dose determinations with physical models of Reference Man. The dosimeter used was a thermo-luminescent dosimeter (TLD) powder which was mixed with a 'tissue-equivalent' material and modeled to closely approximate an organ's geometry and absorption properties. A separation procedure was developed by which the TLD powder was washed and the 'tissue-equivalent' material, a wax, was dissolved and extracted following the irradiation of the model. The procedure was tested to determine losses of powder, homogeneity of the powder's distribution throughout the wax, the effects of the separation procedure upon the powder and the statistical behavior of the procedure. The results of these tests established the feasibility of the procedure. A full-scale model of the pancreas was tested and the results supported the validity of the technique. (author)
1978-12-01
Energy Technology Data Exchange (ETDEWEB)
Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be the methods of choice. Pronounced MR image nonuniformity ...
2001-03-01
Energy Technology Data Exchange (ETDEWEB)
Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, spectrometry, kerma distributions, coupled multigroup ...
1983-01-01
International Nuclear Information System (INIS)
Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, spectrometry, kerma distributions, coupled multigroup ...
7871-01-01
Scatter measurements for optical cone-beam computed tomography
Energy Technology Data Exchange (ETDEWEB)
Both x-ray and optical cone-beam CT (CBCT) scanners are limited by scattered photons that contaminate the primary images. Transparent radiochromic gels and plastics are anticipated to produce less scattering than polymerization gels and hence result in reconstructed dose distributions with greater contrast and dynamic range. Four methods of scatter measurement were investigated to quantify scatter fractions using an in-house optical CBCT scanner. The methods consisted of generating either 'coin' shadows or primary beamlets in transmission images. The four methods generated similar results of 10% scatter fractions in gel transmission images for this particular scanner configuration with both leuco crystal violet and carbon black micelle gels. The scatter contributions were distributed as 5% from micelle gel, 2% from Teflon wall, 2% from refractive index matching liquid and 1% other sources. Applying a ...
2009-05-01
International Nuclear Information System (INIS)
Magnetic particles (MAG*SEP"S"M) coated with various absorbents were evaluated for the separation and recovery of low concentrations of cesium from nuclear waste solutions. The MAG*SEP"S"M particles were coated with (1) clinoptilolite, (2) transylvanian volcanic tuff, (3) resorcinol formaldehyde, and (4) crystalline silico-titanate, and then were contacted with a Hanford supernatant simulant. Particles coated with the crystalline silico-titanate were identified by Bradtec as having the highest capacity for cesium removal under the conditions tested (variation of pH, ionic strength, cesium concentration, and absorbent/solution ratio). The MAG*SEP"S"M particles coated with resorcinol formaldehyde had high distribution ratios values and could also be used to remove cesium from Hanford supernant simulant. Gamma irradiation studies were performed on the MAG*SEP"S"M particles with a gamma dose equivalent to 100 cycles of use. This irradiation ...
1994-05-09
The characteristics of surface oxidation and corrosion resistance of nitrogen implanted zircaloy-4
International Nuclear Information System (INIS)
This work is concerned with the development and application of ion implantation techniques for improving the corrosion resistance of zircaloy-4. The corrosion resistance in nitrogen implanted zircaloy-4 under a 120 keV nitrogen ion beam at an ion dose of 3 x 10"1"7 cm"-"2 depends on the implantation temperature. The characteristics of surface oxidation and corrosion resistance were analyzed with the change of implantation temperature. It is shown that as implantation temperature rises from 100 to 724 C, the colour of specimen surface changes from its original colour to light yellow at 100 C, golden at 175 C, pink at 300 C, blue at 440 C and dark blue at 550 C. As the implantation temperature goes above 640 C, the colour of surface changes to light black, and the surface becomes a little rough. The corrosion resistance of zircaloy-4 implanted with nitrogen is sensitive to the implantation temperature. The pitting potential of specimens increases from 176 to 900 mV ...
Energy Technology Data Exchange (ETDEWEB)
The processes of lung growth, injury, and repair are characterized by alterations in fibroblast synthesis and interstitial distribution of extracellular matrix components. Transforming growth factor beta (TGF-beta), which is postulated to play a role in modulating lung repair, alters the distribution of several matrix components such as collagen and fibronectin. We studied the effect of TGF-beta on the synthesis and distribution of the various glycosaminoglycans (GAGs) and whether these effects may explain its role in lung repair. Human diploid lung fibroblasts (IMR-90) were exposed to various concentrations of TGF-beta (0-5 nM) for variable periods of time (0-18 h). Newly synthesized GAGs were labeled with either (3H)glucosamine or (35S)sulfate. Individual GAGs were separated by size exclusion chromatography after serial enzymatic and chemical digestions and quantitated using scintillation counting. There was a ...
1990-09-01
Pressure-induced structural transitions in multi-walled carbon nanotubes
British Library Electronic Table of Contents (United Kingdom)
We demonstrate a novel cross-sectional deformation, called the radial corrugation, of multi-walled carbon nanotubes (MWNTs) under hydrostatic pressure. Theoretical analyses based on the continuum elastic approximation have revealed that MWNTs consisting of more than ten concentric walls undergo elastic deformations at critical pressure Formula Not Shown , above which the circular shape of the cross-section becomes radially corrugated. Various corrugation modes have been observed by tuning the innermost tube diameter and the number of constituent walls, which is a direct consequence of the core-shell structure of MWNTs. Cross-sectional views of MWNT under high hydrostatic pressure: elliptic deformation with the mode index n = 2 (left), and radial corrugations with n = 5 (center), and n = 6 ...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
The possibility of controlling the radial electric field of toroidal plasmas by injecting high energy electrons along the reversible loss cone orbit of the helical magnetic traps is investigated. It is well known that the radial electric field plays an important role in the confinement improvement scenario especially in the low collisional regime under the physics picture of neoclassical theory. For this purpose, it is made clear that the most suitable particles are transit particles, which show a transition from helically trapped orbits to blocked ones. It is also found that a parallel AC electric field launched from outside assists this transition and makes it possible for particles to penetrate deeply into the plasma. In addition we clarify that the viscosity of the plasma coupled with the helical field configuration provide a bifurcation of plasma states and its stable solution results in confinement improvement. (author)
1999-08-01
Energy Technology Data Exchange (ETDEWEB)
The present paper describes the application of the commercial CFD-code FLUENT 6.1 to the numerical simulation of the flow field in a high specific speed radial fan. Two-dimensional as well as three-dimensional computations are performed using the steady 'Frozen-Rotor method' as well as the unsteady 'Sliding-Mesh method'. The predicted performance curves of the radial fan are compared with the results obtained from measurements on a test stand. Due to the relatively low computation times, the 'Frozen-Rotor method' can be used routinely for design purposes. The results of this approach can be improved if the leakage flow through the gap between the inlet nozzle and the impeller is taken into account. (orig.)
2005-11-01
Measurement of the dark matter velocity anisotropy profile in galaxy clusters
Dark matter particles form halos that contribute the major part of the mass of galaxy clusters. The formation of these cosmological structures have been investigated both observationally and in numerical simulations, which have confirmed the existence of a universal mass profile. However, the dynamic behaviour of dark matter in halos is not as well understood. We have used observations of 16 equilibrated galaxy clusters to show that the random velocities of dark matter particles are larger on average along the radial direction than along the tangential, and that the magnitude of this velocity anisotropy is radially varying. Our measurement implies that the collective behaviour of dark matter particles is fundamentally different from that of normal particles and the radial variation of the anisotropy velocity agrees with the predictions of numerical simulation.
2008-01-01
Erosive radially-slotted discharge in sheet current mode
New non-stationary non-contracted form of the erosive radially-slotted discharge as a thin round sheet with the current of the azimuth direction have been discovered, its existence beings stipulated by a radial transport-wave fluxes. Characteristic features of this discharge is self-confinement of the discharge current magnitude, corresponding decrease of the current pulse duration and occurrence of an energy and substance ejection with rather unusual properties. Measurements of kinetics of the discharge current, the plasma radiation intensity and an electrical probe signal, as well as the transmission electron microscope investigations of characteristic aerodisperse aggregates arising the erosive phase, have been carried out. The probe signal duration was about 10 times greater than that of the current; its kinetics was complicated suggesting existence in the slot of two components with fundamentally different properties and states of the ...
2001-01-01
Electrical drilling string separator
Energy Technology Data Exchange (ETDEWEB)
The separator can be used for electrical separation of the drilling string used as the channel of communication with transmission of face information. It contains upper and lower metal conductors electrically insulated from each other by an insulator made of layered polymer composite material. In order to improve reliability of the connection of the conductors to the insulator and reduce the metal consumption on the ends of the conductors that come into contact with the insulator there are graduated niches with radial projections. The latter form jointly with the layers of the insulator a crown-radial-multiple stage undetachable connection. The niches decreases from the outer diameter of the conductors to the inner. The insulator has additional layers made of high-module fibers of carbon or boron which cover the radial projections in stages.
1983-01-01
Acoustic resonances in two-dimensional radial sonic crystal shells
Energy Technology Data Exchange (ETDEWEB)
Radial sonic crystals (RSC) are fluidlike structures infinitely periodic along the radial direction that verify the Bloch theorem and are possible only if certain specially designed acoustic metamaterials with mass density anisotropy can be engineered (see Torrent and Sanchez-Dehesa 2009 Phys. Rev. Lett. 103 064301). A comprehensive analysis of two-dimensional (2D) RSC shells is reported here. A given shell is in fact a circular slab with a central cavity. These finite crystal structures contain Fabry-Perot-like resonances and modes strongly localized at the central cavity. Semi-analytical expressions are developed to obtain the quality factors of the different resonances, their symmetry features and their excitation properties. The results reported here are completely general and can be extended to equivalent 3D spherical shells and to their photonic counterparts.
2010-07-15
Metabolic fate of chlorinated paraffins
Energy Technology Data Exchange (ETDEWEB)
The disposition of three (1-/sup 14/C)-chlorododecanes (MCDD, PCDD I and PCDD II; 17.4%, 55.9%, and 68.5% chlorination) was studied in C57Bl mice. (1-/sup 14/C)-lauric acid (LA) was studied as reference compound. Fifty-two percent (MCDD), 32% (PCDD I), and 8% (PCDD II) of the radioactive doses were exhaled as /sup 14/CO/sub 2/ during 12 h after i.v. injection. Similar results were obtained after p.o. administration. In addition to a marked labelling of the liver and fat, the distribution patterns observed at 24 h after administration revealed an uptake of radioactivity in tissues with high cell turnover/high metabolic activity, e.g., intestinal mucosa, bone marrow, salivary glands and thymus. The concentration of radioactivity in these sites and the exhalation of /sup 14/CO/sub 2/, which were inverse to the degree of chlorination, indicate that the chloroalkanes are degraded to metabolites which can be utilized in the intermediary metabolism. A ...
1982-09-01
Indoor radon dose assessment for Osijek
Energy Technology Data Exchange (ETDEWEB)
After ten years' investigation of radon's seasonal variation at three very different locations, as well as radon concentration measurements in kindergartens, schools, air-raid shelters and cellars, systematic indoor radon measurements were undertaken in dwellings (residential buildings) of Osijek (East Croatia, 130andpuncsp; omitted000 citizens). Indoor radon was measured by means of the LR-115 SSNT detector at 48 town locations that gave an arithmetic mean of 71.6 Bq/m{sup 3}, standard deviation of 44.0 Bq/m{sup 3} and geometric mean of 60.1 Bq/m{sup 3}, for the radon concentration range from 22.7 to 185.6 Bq/m{sup 3}. Radon measurements, performed by the silicon Radhome detector, did not differ significantly. The empirical frequency distribution of radon concentrations, with the class width of 20 Bq/m{sup 3}, was in accordance with the theoretical log-normal distribution which was shown with the {chi}{sup 2}-test. The radon ...
1999-05-01
International Nuclear Information System (INIS)
Environmental Survey Laboratory at Tarapur, Maharashtra site carries out environmental radioactivity measurements in different matrices to evaluate the impact of operating nuclear installations. In this paper, the evaluation of data of 1983-2007 (25 years) is presented. Time trends of particulate radioactivity, correlation between "1"3"7Cs in discharge canal seawater and station discharged activity and correlation of "1"3"7Cs, "6"0Co, and "1"3"1I in marine species like Sponge and Nerita and corresponding discharged activity were carried out. Statistical analysis of environmental data of seawater and marine fish for several radionuclides, for distributions, showed that the data best fits lognormal distribution. A strong correlation between "1"3"7Cs in seawater and "1"3"7Cs in liquid waste discharge was observed (R"2 = 0.8, P = 0.000). Similarly correlation was very good for Nerita and discharged concentration for "1"3"7Cs, "1"3"1I and "6"0Co ...
2008-07-16
Convolution/superposition using the Monte Carlo method
International Nuclear Information System (INIS)
The convolution/superposition calculations for radiotherapy dose distributions are traditionally performed by convolving polyenergetic energy deposition kernels with TERMA (total energy released per unit mass) precomputed in each voxel of the irradiated phantom. We propose an alternative method in which the TERMA calculation is replaced by random sampling of photon energy, direction and interaction point. Then, a direction is randomly sampled from the angular distribution of the monoenergetic kernel corresponding to the photon energy. The kernel ray is propagated across the phantom, and energy is deposited in each voxel traversed. An important advantage of the explicit sampling of energy is that spectral changes with depth are automatically accounted for. No spectral or kernel hardening corrections are needed. Furthermore, the continuous sampling of photon direction allows us to model sharp changes in fluence, such as those ...
2003-07-21
Energy Technology Data Exchange (ETDEWEB)
Silicon on insulator (SOI) structures are promising candidates for the fabrication of VLSI circuits with very high packing densities. The preparation of such structures can now be achieved by high dose implantation of reactive ion species such as oxygen to produce buried layers of SiO/sub 2/ in silicon. In this paper we report experiments to depth profile these layered structures by SIMS. SOI samples have been prepared by implanting (100) silicon wafers with 400 keV molecular oxygen ions at a dose of 1.8x10/sup 18/ O/sup +/ cm/sup -2/. During the implantation the wafers were maintained at temperatures between 325 and 600/sup 0/C, using beam heating, which achieved in situ-annealing and ensured that the top silicon layer remained single crystal. Analysis was carried out on an Atomika DIDA-II spectrometer using 10 keV Ar/sup +/ ions with a low current density of less than 1 mA cm/sup -2/. During analysis negative secondary ions were monitored ...
1983-12-15
Modeling marrow damage from response data: Morphallaxis from radiation biology to benzene toxicity
Energy Technology Data Exchange (ETDEWEB)
Consensus principles from radiation biology were used to describe a generic set of nonlinear, first-order differential equations for modeling of toxicity-induced compensatory cell kinetics in terms of sublethal injury, repair, direct killing, killing of cells with unrepaired sublethal injury, and repopulation. This cellular model was linked to a probit model of hematopoietic mortality that describes death from infection and/or hemorrhage between {approximately} 5 and 30 days. Mortality data from 27 experiments with 851 doseresponse groups, in which doses were protracted by rate and/or fractionation, were used to simultaneously estimate all rate constants by maximum-likelihood methods. Data used represented 18,940 test animals distributed according to: (mice, 12,827); (rats, 2,925); (sheep, 1,676); (swine, 829); (dogs, 479); and (burros, 204). Although a long-term, repopulating hematopoietic stem cell is ancestral to all lineages needed to ...
1995-12-01
Concept of malignant significant factor and its applicability for and occupational exposures
International Nuclear Information System (INIS)
In the medical and occupational exposures, there is a tradition to use the genetically significant dose as an index of harm to the population although it only includes the genetical effects from ionizing radiations. A similar significant dose for somatic effects such as radiation leukemogenesis and carcinogenesis should be added to the genetically significant dose in order to approach an index of total harm to the population from medical and occupational exposures. For this purpose, leukemia and malignant significant factors were determined based on the induction of malignant diseases including leukemia for the atomic bombs in Hiroshima and Nagasaki and the life expectancy of individuals subject to medical examinations or treatments as well as radiation workers, taking account of the possibility of their deaths due to other diseases or accidents during a latent period of malignant diseases. The resultant significant factors ...
1980-01-01
A campaign of discrete radon concentration measurements in soil of Niska Banja town, Serbia
Energy Technology Data Exchange (ETDEWEB)
The first radon soil gas survey in Serbia, using passive detectors (SSNTD, CR-39), was carried out in June 2005 at field sites in Niska Banja town. The aim of the survey was to identify risk zones characterised by high levels of this radioactive gas. Radon measurements were made at the depth of 50 cm, in the ground according to a systematic grid pattern. Furthermore, at all 48 measurement points, the surface gamma dose rates in the air was also measured at the same locations and soil samples were collected for gamma spectrometric analysis for the radionuclides {sup 226}Ra, {sup 228}Th and {sup 40}K. Radon concentrations were found to range from 1270 to 155000Bqm{sup -3} with an average of 33765Bqm{sup -3} and a median value of 12626Bqm{sup -3}. The geometrical mean value and geometrical standard deviation were calculated as 16160Bqm{sup -3} and 3.5Bqm{sup -3}, respectively. Gamma dose rate varies from 92 to 316nGyh{sup -1}, with an average of ...
2007-11-15
A campaign of discrete radon concentration measurements in soil of Niska Banja town, Serbia
International Nuclear Information System (INIS)
The first radon soil gas survey in Serbia, using passive detectors (SSNTD, CR-39), was carried out in June 2005 at field sites in Niska Banja town. The aim of the survey was to identify risk zones characterised by high levels of this radioactive gas. Radon measurements were made at the depth of 50 cm, in the ground according to a systematic grid pattern. Furthermore, at all 48 measurement points, the surface gamma dose rates in the air was also measured at the same locations and soil samples were collected for gamma spectrometric analysis for the radionuclides "2"2"6Ra, "2"2"8Th and "4"0K. Radon concentrations were found to range from 1270 to 155000Bqm"-"3 with an average of 33765Bqm"-"3 and a median value of 12626Bqm"-"3. The geometrical mean value and geometrical standard deviation were calculated as 16160Bqm"-"3 and 3.5Bqm"-"3, respectively. Gamma dose rate varies from 92 to 316nGyh"-"1, with an average of 132nGyh"-"1. The radium content in ...
2007-11-01
Examples are used to demonstrate that a shift in the point of emphasis is necessary with regard to radiation hazard in medicinal X-ray diagnosis. The parameters employed in this study to calculate somatic dose (SD) and somatically significant dose (SSD) m...
1980-01-01
Radiation dose in computerized tomography
International Nuclear Information System (INIS)
Dosimetric studies in 80 patients examined with the tomographic device 'Somatom' are reported. The gonad doses are compared to those of conventional radiographic techniques.
Perturbations of the Plebanski metric in general relativity. II. Perturbations of the fermion field.
We obtain the radial Dirac equations for the Plebanski metric and transform these equations into one-dimensional wave equations. Finally we conclude with the result that the electron and the neutrino fields are not superradiant.
1986-09-01
International Nuclear Information System (INIS)
The present emphasis on inherent safety for liquid-metal reactor designs has resulted in a need to represent the various reactivity feedback mechanisms as accurately as possible. The dominant negative reactivity feedback has been found to result from radial expansion of the core for most postulated anticipated transient without scram events. For this reasons, a more detailed model for calculating the reactivity feedback from radial core expansion, including subassembly bowing has been recently developed for use with the SASSYS/SAS4A code system. The purpose of this summary is to present an extension to the model so that it is more suitable for handling a core restraint design as used in the Fast Flux Test Facility (FFTF), and to compare the SASSYS/SAS4A results using this model to the empirical correlation presently being used to account for radial core expansion reactivity feedback in the FFTF.
1987-11-15
Indoor radon concentration measurements in Tarqumia Girl Schools at Western Hebron Region, Palestine
International Nuclear Information System (INIS)
In this study, radon-222 in indoor air was surveyed in 62 rooms located in four governmental schools, for girls, in Tarqumia town that lies in the north western part of Hebron city in Palestine. The annual effective dose equivalents resulting from the inhalation of radon and its daughters by 2318 pupils and 102 staff members occupying the surveyed rooms were also measured. TASTRAK, a solid state nuclear track detector, has been used to measure the indoor radon concentrations at those schools thus, 124 radon detectors were distributed in the four school buildings. The radon detectors stayed for 70 days between February 2006 and April 2006. The results showed that the radon concentration and the annual effective dose equivalent in these schools were varied from 12 to 232.5 Bq/m"3 with an average of 34.1 Bq/m"3 and 0.62 to 12.0 mSv/y with an average of 1.76 mSv/y, respectively. The mean values of radon concentrations in ...
Energy Technology Data Exchange (ETDEWEB)
The measuring series was performed from November 1991 through April 1992 in seven drinking-water conditioning plants of the Fichtel mountains area in the north-eastern part of Bavaria, and the results revealed as an annual average a dose of about 1 - 40 WLM. The area of interest is a drinking-water catchment area where the ground water and other water resources include waters particularly rich in radon content, which explains this relatively high dose range. This is why comprehensive, specific local and long-term mearurements were carried out in order to assess the occupational radiation dose in the drinking-water conditioning plants, taking as a model site the conditioning plant of the municipal utilities of Hof in Weissenstadt. These more specific measurements were performed by the Technical Inspectorates (TUeV) of Bavaria and Saxony and the isotope laboratory of Georg-August University of Goettingen in mid-April 1994 ...
1995-03-01
The malignancy significant dose from external beam radiotherapy
International Nuclear Information System (INIS)
In the present study an estimate is made of the malignancy significant dose from external beam radiotherapy in New Zealand utilizing data obtained in a survey conducted in 1975. This survey had been designed to assess genetically significant dose. A weighted effective dose equivalent is derived from the malignancy significant dose for direct comparison with mean per capita effective dose equivalents arising from other sources of radiation. 14 refs., 1 fig., 8 tabs.
1987-01-01
Further means for reducing radiation dose during exposure of the pelvis in infants
International Nuclear Information System (INIS)
A simple dose-saving procedure for the diagnosis of congenital hip dysplasia employing a diaphragm in nearfocus position is presented. Doses to the skin and the gonads were measured with a phantom for the new and other techniques. With optimal techniques the skin dose is smaller than 2 mR and the gonadal doses lie around 0.1 mR for both male and female patients. An estimate of the dose burden from undesired radiation is appended. (orig.).
Fishes of Georgia: Georgia Freshwater Fish Distribution, Classification, and Information
Georgia Fish: Freshwater fish distributions,classification, conservation status, and distribution comments for Georgia....
The root cause analysis of 9DVN002ZV fan failure in Daya Bay Nuclear Power Station
International Nuclear Information System (INIS)
Extensive investigations and detailed analysis of the failure reason of 9DVN002ZV fan in Daya Bay Nuclear Power Station showed that the fan destroy was caused by the failure of non-drive end bear. The direct cause of this bearing' failure was its improper assembly caused by improper maintenance procedure, and the root cause was too small internal radial clearance after mounting. The factor affecting bearing internal radial clearance, the relationship between clearance and operating life time and fan failure process were discussed. (authors)
2005-09-01
Flywheel energy storage construction; Vliegwielenergieopslaginrichting
Energy Technology Data Exchange (ETDEWEB)
The title invention aims at a vibrations-free running of the flywheel to realize a high speed (18,000-20,000 revolutions per minute). The flywheel consists of a case which holds a central stator, a rotor and two ball-bearings. The ball-bearings have a first radial stiffness and are placed in between the rotor and an upper, respectively lower support bearer. The support bearers are supported on the stator with a second radial stiffness. The top and the bottom of the stator is connected to the case by means of a support with a third stiffness. 6 figs.
1995-06-01
Dynamics of the Edge Transport Barrier at Plasma Biasing on the Castor Tokamak
International Nuclear Information System (INIS)
A clear and reproducible transition to a regime with an improved particle confinement is routinely observed on the CASTOR tokamak, if the biasing electrode is inserted deep enough into the plasma (r/a?0.5) and biased up to +250 V. The steepening of the radial profiles of the plasma density and potential demonstrate the formation of a transport barrier just inside the last closed flux surface. Fast relaxations of the edge plasma parameters, with a frequency of about 10 kHz, are observed when the average radial electric field within the barrier prevails values of about 20 kV/m. A detailed analysis of the spatial-temporal behaviour of these relaxations is presented.
2006-01-01
Analysis of Longitudinal Space Charge Effects With Radial Dependence
Energy Technology Data Exchange (ETDEWEB)
Longitudinal space charge (LSC) force can be a main effect driving the microbunching instability in the linac for an x-ray free-electron laser (FEL). In this paper, the LSC-induced beam modulation is studied using an integral equation approach that takes into account the transverse (radial) variation of LSC field for both the coasting beam limit and bunched beam. Changes of beam energy and the transverse beam size can be also incorporated. We discuss the validity of this approach and compare it with other analyses as well as numerical simulations.
2005-09-30
A note on the pressure field within an outward moving free annulus
Energy Technology Data Exchange (ETDEWEB)
The outward radial expansion of a free liquid annulus is a common problem of both earlier and current ICF blanket design. Whether the annulus fractures or not depends on the internal pressure and surface stability. In this paper a model based on incompressible cylindrically symmetric flow is used to get a theoretical solution similar to that of the Rayleigh's solution for bubble dynamics. The pressure inside the annulus is found positive all time but the peak is lowering during the expansion. Besides, both surfaces are Taylor stable during such motion. Thus, it is concluded that an annulus in outward radial motion will not cavitate or breakup.
1990-01-01
104 MeV alpha particle scattering from /sup 90/,/sup 92/Zr
Energy Technology Data Exchange (ETDEWEB)
Differential cross sections have been measured for the elastic and inelastic scattering of 104 MeV alpha-particles from /sup 90/,/sup 92/Zr. The experimental data are analyzed in terms of coupled channels on the basis of a flexible anharmonic vibrator model and using different parametrizations of the radial shape of the extended optical potential. The results favour the squared Saxon-Woods type for the real part. Additionally to a radial momentum analysis of the real potentials a semimicroscopic folding model has been invoked for extracting isoscalar quadrupole and hexadecapole transition rates.
1982-05-01
104 MeV alpha particle scattering from "9"0,"9"2Zr
International Nuclear Information System (INIS)
Differential cross sections have been measured for the elastic and inelastic scattering of 104 MeV alpha-particles from "9"0,"9"2Zr. The experimental data are analyzed in terms of coupled channels on the basis of a flexible anharmonic vibrator model and using different parametrizations of the radial shape of the extended optical potential. The results favour the squared Saxon-Woods type for the real part. Additionally to a radial momentum analysis of the real potentials a semimicroscopic folding model has been invoked for extracting isoscalar quadrupole and hexadecapole transition rates. (orig.).
THE DOUBLE-DEGENERATE NUCLEUS OF THE PLANETARY NEBULA TS 01: A CLOSE BINARY EVOLUTION SHOWCASE
International Nuclear Information System (INIS)
We present a detailed investigation of SBS 1150+599A, a close binary star hosted by the planetary nebula PN G135.9+55.9 (TS 01). The nebula, located in the Galactic halo, is the most oxygen-poor known to date and is the only one known to harbor a double degenerate core. We present XMM-Newton observations of this object, which allowed the detection of the previously invisible component of the binary core, whose existence was inferred so far only from radial velocity (RV) and photometric variations. The parameters of the binary system were deduced from a wealth of information via three independent routes using the spectral energy distribution (from the infrared to X-rays), the light and RV curves, and a detailed model atmosphere fitting of the stellar absorption features of the optical/UV component. We find that the cool component must have a mass of 0.54 #+-# 0.2 M_s_u_n, an average effective temperature, T_e_f_f, of 58,000 #+-# 3000 K, a mean ...
2010-05-01
Radioactive lead studies in the human
International Nuclear Information System (INIS)
The differing susceptibility of individuals to the toxic effects of chronic lead exposure has never been fully understood. As the major intake of lead in the human is from food and beverages, any variation between individuals of the quantity of lead absorbed from the gut, and of the distribution and excretion of this lead, may account for the differences in individual susceptibility. The food and beverages themselves may have an influence, and to investigate their effects on absorption, distribution and excretion of lead, experiments were performed on normal subjects using a short lived radionuclide of lead, "2"0"3Pb, and instruments generally available in Nuclear Medicine. Lead absorption between different individuals showed a wide variation when "2"0"3Pb was taken as a single dose between meals. Minerals were found to be mainly responsible for affecting absorption when one subject ingested "2"0"3Pb in control meals from ...
Effect of electron irradiation on domain wall pinning defects in 50-50 NiFe
International Nuclear Information System (INIS)
A magnetic measuring technique, which sorts out defects according to a distribution function n, was used to study the influence of electron irradiation on 50-50 NiFe. The distribution function is determined in terms of the maximum force f/subm/ that a defect can exert on a forward moving domain wall, or equivalently, the range z_0, which is the distance the mean position of the wall may move past the defect before the wall snaps free from the pinning action of the defect. The range and maximum force are related by a spring constant k, viz., f/subm/=kz_0. The quantity n (z_0) dz_0 gives the number of defects per unit volume having a range between z_0 and z_0+dz_0. Distribution functions were determined before and after electron irradiation. The irradiation was for 100 min with 18-MeV electrons with a dose of 1.1times10"1"7 e/cm"2. Following irradiation, there was a substantial decrease in the number of ...
Energy Technology Data Exchange (ETDEWEB)
The importance of cellular dosimetry in both diagnostic and therapeutic nuclear medicine is becoming increasingly recognized. Experimental range-energy relations for electrons and alpha particles, along with derived geometric reduction factors, are used to calculate cellular absorbed fractions for these radiations. The resulting absorbed fractions are employed to calculate cellular S-values for several radionuclides. Cellular absorbed fractions for monoenergetic electron sources with energies ranging from 0.1 keV to 1 MeV, distributed uniformly in the source region, are calculated for several target {l_arrow} source combinations including cell{l_arrow}cell, cell{l_arrow}cell surface, nucleus{l_arrow}nucleus, nucleus {l_arrow}cytoplasm and nucleus {l_arrow}cell surface. Similar data are also provided for monoenergetic alpha particle sources with energies ranging from 3 to 10 MeV. S-values are also conveniently tabulated for {sup 32}P, {sup 35}S, {sup 86}Rb, {sup ...
1994-02-01
Development of barcode system for internal dose monitoring
International Nuclear Information System (INIS)
In Tarapur Atomic Power Station unit-3 and 4, which is 540 MWe pressurized heavy water reactor, tritium is produced in primary heat transport system and moderator system. Tritium is a major contributor to the internal dose. Internal dose contributes about 30% of the collective dose. Internal dose monitoring and its control are important to control the collective dose. Estimation of internal dose is done by analysis of bioassay samples of radiation workers. In a month, about 7000 bioassay samples are analysed for the internal dose assessment during normal operation, and about 12000 during the biennial shut down of the reactor. To enhance the sample preparation and counting performance, minimize the entry errors and reduce the processing time, barcode based label generation system was developed for the internal dose ...
2008-11-19
Energy Technology Data Exchange (ETDEWEB)
LEDF(Large Equipment Dismantling Facility) is the solid waste processing technology development facility that carries out high-volume reduction and low dosage processing. The high-volume reduction processing of the high dose {alpha}-waste configured with combustible waste, pvc and rubber, spent ion exchange resin, and noncombustible waste have been planned the incinerating and melting facility using the in-can type high frequency induction heating in LEDF. This test is intended to clarify the design data. It was confirmed that the incinerating and melting performance, molten solid properties and exhaust gas processing performance with pilot testing equipment and bench scale equipment. The result of this test are as follows. 1. Processing speed is 6.7 kg/h for the combustible waste, 13.0 kg/h for the ion exchange resin, and 30.0 kg/h for the noncombustible waste. For above optimum processing conditions are as follows. Operating temperature is 1000degC for the ...
1999-12-01
Energy Technology Data Exchange (ETDEWEB)
Radiation therapy has had a significant and an expanded role in the management of cancer of the pancreas during the last decade. In particular, for locally advanced disease, radiation therapy has improved the median survival of patients to 1 year. Intraoperative electron beam therapy has been applied to unresectable and resectable pancreatic cancer in an attempt to enhance local control of disease and to improve patient survival. This paper presents a survey of the role of radiation therapy in treatment of cancer of the pancreas, provides information on the radiobiological aspects of this treatment modality and details the physical and dosimetric characteristics of intraoperative radiation therapy with electrons. Presented are the design specifics of an applicator system, central axis beam data, applicator parameters, dose distribution data, shielding, treatment planning and means of verification. Emphasis is placed on the collaboration and ...
1989-01-01
International Nuclear Information System (INIS)
Radiation therapy has had a significant and an expanded role in the management of cancer of the pancreas during the last decade. In particular, for locally advanced disease, radiation therapy has improved the median survival of patients to 1 year. Intraoperative electron beam therapy has been applied to unresectable and resectable pancreatic cancer in an attempt to enhance local control of disease and to improve patient survival. This paper presents a survey of the role of radiation therapy in treatment of cancer of the pancreas, provides information on the radiobiological aspects of this treatment modality and details the physical and dosimetric characteristics of intraoperative radiation therapy with electrons. Presented are the design specifics of an applicator system, central axis beam data, applicator parameters, dose distribution data, shielding, treatment planning and means of verification. Emphasis is placed on the collaboration and ...
International Nuclear Information System (INIS)
Non-destructive methods of diagnosis for detecting cable degradation by aging are being studied recently for improvement of electric wires and cables. This study examines degradation behaviors of cable sheath and insulation by combined accelerated aging tests applying thermal and radiation stresses simultaneously using a typical low voltage cable. According to experiments, elongation of cross-linked polyethylene insulation deteriorated at a faster rate than PVC sheath did under low doses below 50 Gy/h. Therefore, measurements using a time domain dielectric spectrometer (TDS) were carried out for the purpose of developing a method of degradation diagnosis of insulation. It was found that values of tan#delta# measured at very low frequencies below 0.1 Hz increase in pace with degradation of insulation reflecting the level of degradation more effectively than those measured at frequencies around the commercial frequency. In order to consider causes of the increases of ...
2000-05-01
Energy Technology Data Exchange (ETDEWEB)
The radioiodine-labeled amines currently available as brain-imaging agents, based on our previous work and that of others, are prepared either by exchange labeling or by direct iodination of a protected intermediate. The intrinsic slowness of these processes limits their potential for use with the positron-emitting 122I, as it has a half-life of only 3.6 min. This isotope has advantages of a low dose to the patient and availability from a generator containing the parent 20-h 122Xe. To develop a radiopharmaceutical in which 122I could be utilized, we prepared a number of secondary and tertiary amines (maintaining the 2,5-dimethoxy substitution pattern which allows direct iodination at the 4-position) with 131I. The organ distributions of these compounds were studied, and the best properties were found in the N,N-dimethyl homologue (2,5-dimethoxy-N,N-dimethyl-4-iodoamphetamine). This compound was successfully synthesized in a matter of seconds, ...
1984-08-01
International Nuclear Information System (INIS)
The radioiodine-labeled amines currently available as brain-imaging agents, based on our previous work and that of others, are prepared either by exchange labeling or by direct iodination of a protected intermediate. The intrinsic slowness of these processes limits their potential for use with the positron-emitting 122I, as it has a half-life of only 3.6 min. This isotope has advantages of a low dose to the patient and availability from a generator containing the parent 20-h 122Xe. To develop a radiopharmaceutical in which 122I could be utilized, we prepared a number of secondary and tertiary amines (maintaining the 2,5-dimethoxy substitution pattern which allows direct iodination at the 4-position) with 131I. The organ distributions of these compounds were studied, and the best properties were found in the N,N-dimethyl homologue (2,5-dimethoxy-N,N-dimethyl-4-iodoamphetamine). This compound was successfully synthesized in a matter of seconds, ...
Quality Management for Neutron Transmutation Doping of Silicon Ingot in HANARO
Energy Technology Data Exchange (ETDEWEB)
By using this doping method, silicon semiconductors with extremely uniform dopant distributions can be produced, and this is the dominant advantage of NTD compared with a conventional chemical doping. Good uniformity of a dopant concentration is usually required for high power applications such as thyristor (SCR), IGBT, IGCT and GTO and for special sensors. Achieving an accurate neutron fluence corresponding to a target resistivity as well as a uniform irradiation is the prime target of a neutron irradiation for NTD. Generally, in order to reach an accurate neutron fluence, a real time neutron flux is monitored by a neutron detector such as a Self-powered Neutron Detector(SPND). And, after an irradiation, the total irradiation fluence is confirmed by measuring the absolute activity of a neutron activation sample that has been irradiated with a silicon ingot, and thus the SPND can be properly calibrated. Excellent irradiation uniformity and a high accuracy for a ...
2007-10-15
Kinetics of self-interstitial cluster aggregation near dislocations and their influence on hardening
International Nuclear Information System (INIS)
Kinetic Monte Carlo (KMC) computer simulations are performed to determine the kinetics of SIA cluster 'clouds' in the vicinity of edge dislocations. The simulations include elastic interactions amongst SIA clusters, and between clusters and dislocations. Results of KMC simulations that describe the formation of 'SIA clouds' during neutron irradiation of bcc Fe and the corresponding evolution kinetics are presented, and the size and spatial distribution of SIA clusters in the cloud region are studied for a variety of neutron displacement damage dose levels. We then investigate the collective spatio-temporal dynamics of SIA clusters in the presence of internal elastic fields generated by static and mobile dislocations. The main features of the investigations are: (1) determination of the kinetics and spatial extent of defect clouds near static dislocations; (2) assessment of the influence of localized patches of SIA clouds on the ...
2009-08-01
Energy Technology Data Exchange (ETDEWEB)
Individual monitoring of personal exposure to inhalation of uranium oxides throughout the manufacture of fuel for pressurized water reactor (PWR) includes lung gamma-spectrometry, fecal analysis and urine analysis. Examination of the results shows the following: internal exposure is the consequence of repeated intake incidents as revealed by early peaks of urinary and particularly fecal elimination; a shift is often observed with the results of aerosol concentration measured through air collectors; the measured variations of uranium lung incorporations are relatively fast (apparent mean period 165 d). Correct evaluation of the effective dose equivalent from inhalation requires further information concerning the aerosol size distribution at work stations, the physico-chemical characteristics of the product leading to an estimate of its actual biological solubility, and the measurement of the fraction of aerosol liable to intake with an ...
1989-01-01
Hydrogen behavior in the iron surface layer modified by plasma nitriding and ion boronising
Energy Technology Data Exchange (ETDEWEB)
The effects of the plasma nitriding with the formation of compound nitride and diffusion zones and of the boronising with the different ion doses on hydrogen distribution and hydrogen induced deterioration of a surface layer were examined in the case of Armco iron. Electrochemical studies of hydrogen permeation rate, hydrogen vacuum extraction measurements, optical and scanning microscopy, X-ray diffraction and elastic recoil detection analysis (ERDA) were used. Accumulation of entering hydrogen within the various constituent zones of the modified layer inhibits the hydrogen transport into the metal and thus, decreases the mean hydrogen content in the deeper zones and in the core. Hydrogen accumulation within the compact nitride zone causes the expansion of the nitride lattice, nitride phase transformation and deterioration. The ion boronising enhances the hydrogen effects in the plasma nitrided layers. Therefore, modification of the surface ...
2000-12-01
Energy Technology Data Exchange (ETDEWEB)
Natural radioactive materials under certain conditions can reach hazardous radiological levels. The natural radionuclide ({sup 238}U, {sup 232}Th, {sup 40}K) contents of rock samples at various locations in the North Tushki area were investigated using gamma-spectrometric analysis. Estimates of the measured radionuclide content have been made for the absorbed dose rate of gamma radiation. The equivalent radium (R{sub eq}) and the external hazard index (H{sub ex}) which resulted from the natural radionuclides in soil are also calculated and tabulated. The studied samples have been collected from various rock exposures in the North Tushki area. The distribution of major oxides, U and Th were studied. It is found that the enrichment and depletion of the major oxides are mainly due to the effect of hydrothermal alteration, which caused mobility of some major oxides, which increases some elements and decreases others. It is important to mention that ...
2002-09-01
Effects of interstitial clustering on transient enhanced diffusion of boron in silicon
Energy Technology Data Exchange (ETDEWEB)
A simulation model for boron diffusion which takes into account the aggregation of the excess interstitials in clusters, and subsequently, the dissolution of these defects, is proposed. The interstitial supersaturation and generation rate are determined according to the classical theory of nucleation and growth of particles, in analogy with the precipitation of a new phase in heavily doped silicon. The clusters are considered as precipitates formed by interstitial Si atoms. The B diffusion is modelled on the basis of the dopant-interstitial pair diffusion mechanism. The clusters dissolution during annealing maintains nearly constant, for a long period, the interstitial supersaturation and the related enhancement of the boron diffusion. This gives a good account of the diffusion results over a large range of experimental conditions. Furthermore, this approach describes most of the behavior of the transient enhanced diffusion (TED), like the temperature dependence of the level of the B ...
1997-11-01
Energy Technology Data Exchange (ETDEWEB)
Rats from an inbred Sprague-Dawley strain were fed semisynthetic diets with a low (0.3 energy percent (en %)), normal (3 en %) or high (10 en %) content of essential fatty acids (EFA) for at least three generations. Twenty-nine- to 33-day-old male rats were given a single intragastric dose of (1-14C)linoleic acid in olive oil, and the respiratory CO2, urine and feces were collected for 46 hours (expt 1) or 20 hours (expt 2). The 14C activity in respiratory CO2, feces, urine and the carcass was determined in both experiments. In experiment 2 it was also measured in samples of the brown fat, liver, adrenals, white fat, skeletal muscles and brain. In both experiments the rats fed the low EFA diet retained significantly more 14C activity than the rats fed the normal or high EFA diets. In all groups the concentration of label was highest in the brown fat and the adrenals, but the above differences among the groups with respect to 14C retention were mainly observed in ...
1984-09-01
Energy Technology Data Exchange (ETDEWEB)
Authors developed a C-arm type radiosurgery system of the linear accelerator suitable for stereotactic radiation therapy and a software for arranging 3-dimensional therapy in the system. In this system, the gantry far conical irradiation of 4 MV (0.6-3 Gy/min) and 6 MV (0.9-4.5 Gy/min) X ray or electron beam for the therapy was connected to a newly designed C-arm and was made capable of rotating around either of the axes crossing vertically. With this system, it became unnecessary to move the bed table of the patient for getting suitable distribution of radiation dose. The local accuracy which was measured by the CCD videocamera on the gantry, was within 0.5 mm from the radiation center. The system made it possible to shorten the irradiation time and to improve the local accuracy of irradiating site. The clinical trial was begun from June, 1996. (K.H.)
1996-10-01
International Nuclear Information System (INIS)
The fabrication and complete evaluation are described of a dihydropyridine in equilibrium pyridinium salt type redox system for the delivery of radioiodinated agents to the brain. The pivotal intermediate, N-succinimidyl (1-methylpyridinium iodide)-3-carboxylate was prepared by condensation of nicotinic acid and N-hydroxysuccinimide in the presence of dicyclohexylcarbodimide, followed by quaternization of III with methyl iodide. Tissue distribution studies of "1"2"5I-labeled 4-iodoaniline and the redox agents were performed in rats. ["1"2"5I]Iodoaniline initially showed moderate (0.58% dose/gm) brain uptake with subsequent release of the radioactivity from the brain. ["1"2"5I]Iodoaniline, when coupled to a dihydropyridine carrier showed higher uptake and retention in the brain. The ["1"2"5I]iodophenylethyl analogue showed uptake and retention in the brain to be very similar. Apparently the lipophilic agents cross the blood-brain barrier and are ...
Energy Technology Data Exchange (ETDEWEB)
Radiotherapy with high-energy carbon ion beams can be more advantageous compared to photons because of better physical dose distribution and higher biological efficiency in tumour cell sterilization. Despite enhanced normal tissue sparing, damage incurred by normal cells at the beam entrance is unavoidable and may affect the progeny of surviving cells in the form of inheritable cytogenetic alterations. Furthermore, the quality of the beam along the Bragg curve is modified by nuclear fragmentation of projectile and target nuclei in the body. We present an experimental approach based on the use of a polymethylmethacrylate (PMMA) phantom that allows the simultaneous exposure to a particle beam of several biological samples positioned at various depths along the beam path. The device was used to measure the biological effectiveness of a 60 MeV/amu carbon-ion beam at inducing chromosomal aberrations in G{sub 0}-human peripheral blood lymphocytes. ...
2007-06-15
Effective dose equivalent concept in radiopharmaceutical dosimetry
Energy Technology Data Exchange (ETDEWEB)
The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source ...
1981-06-01
Effective dose equivalent concept in radiopharmaceutical dosimetry
International Nuclear Information System (INIS)
The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source ...
Absorbed dose and dose reduction in mammography
International Nuclear Information System (INIS)
First, absorbed dose at entrance surface was measured in routine mammography. Secondly, a possibility of dose reduction after introduction of Fuji computed radiography (FCR) system was examined. In a total of 350 mammographic studies including craniocaudal and medilateral projections, average thickness of compressed breast was less than 4 cm and most frequently recorded absorbed dose was 0.2-0.3 cGy (200-300 mrad). Minimum dose to obtain clinically acceptable mammograms in FCR system was estimated by comparing image quality of routine versus reduced dose studies. It was concluded that absorbed dose could be reduced to 1/4 of routine dose without creating significant drawback in diagnosis. (author).
1986-01-01
FEA Analysis of AP-0 Target Hall Collection Lens (Current Design)
Energy Technology Data Exchange (ETDEWEB)
The AP-0 Target Hall Collection Lens is a pulsed device which focuses anti-protons just downstream of the Target. Since the angles at which the anti-protons depart the Target can be quite large, a very high focusing strength is required to maximize anti-proton capture into the downstream Debuncher Ring. The current design of the Collection Lens was designed to operate with a focusing gradient of 1,000 T/m. However, multiple failures of early devices resulted in lowering the normal operating gradient to about 750 T/m. At this gradient, the Lens design fares much better, lasting several million pulses, but ultimately still fails. A Finite Element Analysis (FEA) has been performed on this Collection Lens design to help determine the cause and/or nature of the failures. The Collection Lens magnetic field is created by passing high current through a central conductor cylinder. A uniform current distribution through the cylinder will create a tangential or azimuthal ...
2001-06-22
Patient doses from medical uses of x-rays
International Nuclear Information System (INIS)
A survey to determine the annual genetically significant dose and mean bone-marrow dose to the Australian population from radiological procedures has been undertaken. For diagnostic radiology the following were carried out: determination of the frequency of a procedure; measurement of patient doses using TLD and processing of data and calculation of gonadal and bone-marrow doses.
1981-01-01
Evaluation of transient dose in conveyor type low dose irradiator
International Nuclear Information System (INIS)
In conveyor type irradiators, the movement of conveyor and the product boxes is not there until the source is fully in the irradiation position. In case the conveyor system fails the source must automatically be returned to its shielded storage vault. The dose received by the product during the movement of the source from or to the shield becomes significant if the total dose to be received by the product is small. A study has been carried out for evaluating the transient dose received by onions in the POTON irradiator. The results of the study are discussed in this paper. (author)
2003-03-05
Development of internal dose estimation software on radiation protection
International Nuclear Information System (INIS)
Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)
2008-10-01
Treatment of prostatic cancer using daily intermittent multiportal therapy (DIMT) technique
Energy Technology Data Exchange (ETDEWEB)
In the treatment of prostatic cancer using a newly proposed intermittent multiportal therapy (DIMT), acute reactions, change in tumor marker levels, and complications more than 6 months after treatment were evaluated. From June 1989 to September 1990, 26 patients with prostatic cancer (stage A2, 3 patients; B, 9; C, 2; D, 10; recurrence, 2) were treated. Fifteen patients were followed up for more than one year, with a mean period of 11.6 months. The treatment schedule is 52.5 Gy in 16 fractions in 4 weeks for radical treatment, and 30.0 Gy in 8 fractions in 2 weeks for palliative treatment. The 360 degree rotation about the patient was divided into 16 fractions, and 2 opposing fractions were used in one day as parallel opposed portals to treat the target volume. The fractions were serially treated one per day, so that 8 treatment days produced a total dose of distribution similar to that for conventional conformational therapy. The size of the ...
1992-06-01
An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste
Energy Technology Data Exchange (ETDEWEB)
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm{sup -3} or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the end application itself ...
2007-08-21
An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste
International Nuclear Information System (INIS)
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm"-"3 or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the end application itself set ...
2007-08-21
Shielding options for the ITER conceptual design
Energy Technology Data Exchange (ETDEWEB)
Several shield options were analyzed for the ITER conceptual design to minimize the nuclear responses in the toroidal field (TF) coils. The total nuclear heating in the physics phase and the insulator dose in the technology phase are the most critical parameters in the design process. The first shield option has type 316 stainless steel and water shielding material. Steel and water also serve as structural material and coolant, respectively. The second option is similar to the first except that borated water is used instead of ordinary water. The other two options include a small layer of lead or boron carbide (B{sub 4}C) at the back of the shield. The last three shield options were considered to reduce the nuclear heating in the toroidal field coils relative to the steel/water shield. An optimization process was performed taking into consideration the thermal-hydraulics and the engineering requirements to define the shield configuration. A careful integration was ...
1989-10-01
International Nuclear Information System (INIS)
Diethyldithiocarbamate (DDTC), a chelating agent, is an active metabolite of disulfiram (Antabus) and is used in the rubber industry. The effect of DDTC on the tissue distribution of "2"0"3Pb was studied in rats. Two groups of rats were given an i.v. injection of 100 #mu#Ci "2"0"3Pb (28.6 nmol/kg b.wt.) as lead acetate. After 10 min one group received 2 mmol/kg b.wt. of DDTC as an i.p. injection. Rats were killed 4 and 72 h after injection of "2"0"3Pb and tissue concentration and excretion of "2"0"3Pb was determined by gamma counting. The brain concentration of "2"0"3Pb in DDTC-treated rats was nine times higher than in controls after 4 h and 14 times higher after 72 h. Treatment with DDTC also increased the lead concentration in fat about seven times at both survival intervals. On the other hand, uptake of "2"0"3Pb in bone was reduced by treatment with DDTC and at 4 h also kidney and blood had a lower concentration of "2"0"3Pb in DDTC-treated rats compared to ...
Radiation testing of organic ion exchange resins
International Nuclear Information System (INIS)
A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of "1"3"7Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the exchangers were irradiated with a "6"0Co source to a total absorbed ...
1983-04-11
Radiation testing of organic ion exchange resins
Energy Technology Data Exchange (ETDEWEB)
A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of {sup 137}Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the exchangers were irradiated with a {sup 60}Co source to a total ...
1995-09-01
Radiation inactivation target size of rat adipocyte glucose transporter
Energy Technology Data Exchange (ETDEWEB)
In situ assembly states of rat adipocyte glucose transport protein in plasma membrane (PM) and in microsomal pool (MM) were assessed by measuring target size (TS) of D glucose-sensitive, cytochalasin B binding activity. High energy radiation inactivated the binding in both PM and MM by reducing the total capacity of the binding (B/sub T/) without affecting the dissociation constant (K/sub D/). The reduction in B/sub T/ as a function of radiation dose was analyzed based on classical target theory, from which TS was calculated. TS in the PM of insulin-treated adipocytes was 58 KDa. TS in the MM of noninsulin-treated and insulin-treated adipocytes were 112 and 109 KDa, respectively. With MM, however, inactivation data showed anomalously low radiation sensitivities at low radiation doses showing a shoulder in the semilog plots, which may be due to an interaction with a radiation sensitive inhibitor. With these results, they propose the following ...
1987-05-01
Physical mechanisms of transient enhanced dopant diffusion in ion-implanted silicon
Energy Technology Data Exchange (ETDEWEB)
Implanted B and P dopants in Si exhibit transient enhanced diffusion (TED) during annealing which arises from the excess interstitials generated by the implant. In order to study the mechanisms of TED, transmission electron microscopy measurements of implantation damage were combined with B diffusion experiments using doping marker structures grown by molecular-beam epitaxy (MBE). Damage from nonamorphizing Si implants at doses ranging from 5{times}10{sup 12} to 1{times}10{sup 14}/cm{sup 2} evolves into a distribution of {l_brace}311{r_brace} interstitial agglomerates during the initial annealing stages at 670{endash}815{degree}C. The excess interstitial concentration contained in these defects roughly equals the implanted ion dose, an observation that is corroborated by atomistic Monte Carlo simulations of implantation and annealing processes. The injection of interstitials from the damage region involves the dissolution ...
1997-05-01
Physical mechanisms of transient enhanced dopant diffusion in ion-implanted silicon
International Nuclear Information System (INIS)
Implanted B and P dopants in Si exhibit transient enhanced diffusion (TED) during annealing which arises from the excess interstitials generated by the implant. In order to study the mechanisms of TED, transmission electron microscopy measurements of implantation damage were combined with B diffusion experiments using doping marker structures grown by molecular-beam epitaxy (MBE). Damage from nonamorphizing Si implants at doses ranging from 5x10"1"2 to 1x10"1"4/cm"2 evolves into a distribution of #left brace#311#right brace# interstitial agglomerates during the initial annealing stages at 670 endash 815 degree C. The excess interstitial concentration contained in these defects roughly equals the implanted ion dose, an observation that is corroborated by atomistic Monte Carlo simulations of implantation and annealing processes. The injection of interstitials from the damage region involves the dissolution of #left ...
Energy Technology Data Exchange (ETDEWEB)
The radiation-induced microstructural changes have been studied by cross-sectional transmission electron microscopy for single-crystal {alpha}-Al{sub 2}O{sub 3} samples irradiated with triple ion beams (0.25 MeV H{sup +}, 0.6 MeV He{sup +} and 2.4 MeV O{sup 2+}; `Triple (A)`), (0.33 MeV H{sup +}, 0.45 MeV He{sup +} and 1.3 MeV O{sup +}; `Triple (B)`) and three consecutive single ion beams (0.3 MeV H{sup +} ion followed by 0.6 MeV He{sup +} and then 0.8 MeV O{sup +} ions) at 650 C to doses in the range 0.1-8.4 dpa at the damage peak. In the specimen irradiated with Triple (A), having the same average projected range to a total peak dose of 3.7 dpa, cavities with an average diameter of 13 nm were formed between 1.2 and 1.75 {mu}m in depth causing a swelling of 0.1% at the peak, which is larger than those of the specimens irradiated with other conditions. The extent of the cavity-introduced region is some 40% smaller than observed in the damage ...
1996-10-01
Microstructural evolution of single crystalline Al_2O_3 irradiated with single and triple ion beams
International Nuclear Information System (INIS)
The radiation-induced microstructural changes have been studied by cross-sectional transmission electron microscopy for single-crystal #alpha#-Al_2O_3 samples irradiated with triple ion beams (0.25 MeV H"+, 0.6 MeV He"+ and 2.4 MeV O"2"+; 'Triple (A)'), (0.33 MeV H"+, 0.45 MeV He"+ and 1.3 MeV O"+; 'Triple (B)') and three consecutive single ion beams (0.3 MeV H"+ ion followed by 0.6 MeV He"+ and then 0.8 MeV O"+ ions) at 650 C to doses in the range 0.1-8.4 dpa at the damage peak. In the specimen irradiated with Triple (A), having the same average projected range to a total peak dose of 3.7 dpa, cavities with an average diameter of 13 nm were formed between 1.2 and 1.75 #mu#m in depth causing a swelling of 0.1% at the peak, which is larger than those of the specimens irradiated with other conditions. The extent of the cavity-introduced region is some 40% smaller than observed in the damage region due to the He"+ and the O"+ ions and due to the ...
Effects of irradiation on the microstructural evolution and corrosion resistance of zirconium alloys
International Nuclear Information System (INIS)
Zircaloy-2 and Zircaloy-4 tubing materials were irradiated with 1 MeV proton at 350 degrees C to doses of 0.01, 0.1, and 1 dpa respectively. Both microstructure examination and nodular corrosion test (500 degrees C, 1500 psi steam) were performed in order to understand the relationship between the microstructural evolution and the corrosion resistance of these alloys under irradiation. Neutron-irradiated Zircaloy-2 specimens which were obtained from a failed BWR fuel rod cladding were also studied. Specimens of three different neutron fluences were investigated; namely, 2.6x10"2"4, 3.2x10"2"5, 3.8x10"2"5, (E_n#>=#1MeV). The results indicated that the higher the irradiation dose the better the nodular corrosion resistance of both Zircaloy-2 and Zircaloy-4. It is concluded that irradiation-induced precipitate dissolution and irradiation-enhanced diffusion may increase the solute concentration in the matrix and make it ...
1991-08-25
Energy Technology Data Exchange (ETDEWEB)
Whole-body retention and excretion following a single oral dose of radiolabeled lead (/sup 203/Pb) in chronically lead-exposed pregnant BK:W mice were examined over 10-13 days. This was compared with values in similarly treated nonpregnant females and in ip injected females. Whole-body and bone retention were greater in injected than in orally dosed nonpregnant females; gastrointestinal absorption was estimated from this difference. Whole-body retention in the pups was measured at birth and at the end of the experiment. Whole-body retentions in pregnant females and in their pups at birth were significantly raised after treatment at Gestational Day 17, but not after treatment at Gestational Day 11, 14, 20, 23, or 26. Pup body burdens at birth were significantly and positively correlated with maternal retention. Measurement of radioactivity in bone, kidney, brain, heart, and liver of adults at the end of the experiments showed significantly ...
1986-12-01
International Nuclear Information System (INIS)
Whole-body retention and excretion following a single oral dose of radiolabeled lead ("2"0"3Pb) in chronically lead-exposed pregnant BK:W mice were examined over 10-13 days. This was compared with values in similarly treated nonpregnant females and in ip injected females. Whole-body and bone retention were greater in injected than in orally dosed nonpregnant females; gastrointestinal absorption was estimated from this difference. Whole-body retention in the pups was measured at birth and at the end of the experiment. Whole-body retentions in pregnant females and in their pups at birth were significantly raised after treatment at Gestational Day 17, but not after treatment at Gestational Day 11, 14, 20, 23, or 26. Pup body burdens at birth were significantly and positively correlated with maternal retention. Measurement of radioactivity in bone, kidney, brain, heart, and liver of adults at the end of the experiments showed significantly ...
Energy Technology Data Exchange (ETDEWEB)
The proton beam has a unique advantage over the electron and photon beams in that it can give very high radiation dose to the tumor volume, while effectively sparing the neighboring healthy tissue and organs. For the clinical application of the proton beam, it is very important to confirm the location of the proton beam in the patient, preferentially during the treatment. It has been suggested that the range of the proton beam in the patient can be determined by measuring prompt gammas from the proton beam passage. Recently, a prototype prompt-gamma scanning system has been constructed and tested using experimental and therapeutic proton beams. The measurement results for the proton beams of 70 . 230 MeV showed that a clear correlation exists between the distribution of the prompt gammas and the proton beam range. The scanning method, however, is not suitable for the upcoming 'spot scanning' technique. The 'spot ...
2007-07-01
International Nuclear Information System (INIS)
Since 1994 the radon studies group at the Institut de Techniques Energetiques (INTE) of the Universitat Politecnica de Catalunya in Barcelona, Spain, has carried out a campaign of continuous measurements of the equilibrium factor (F) and the unattached fraction (f_p) of radon decay products at four sites which are representative of different environmental characteristics on the Mediterranean littoral of Catalonia, Spain. It has been established that these parameters vary widely, F(0.03--0.87) and f_p (0--0.72), from one site to another and with time, according to the characteristics on the site and climate. In spite of this variation, the F and f_p parameters are log-normally or normally distributed. The measurements of F and f_p show that f_p is negatively correlated to F by a log-power equation, Ln(1/f_p)=1.90[Ln(1/F)]"-"0"."6"8, which can be used in all the F range, instead of the commonly used power equation f_p=aF"b suggested by Stranden and Strand and other ...
2000-01-01
International Nuclear Information System (INIS)
The authors present the results of an investigation of the effect of gamma radiation on the properties of low-molecular moulded polymethyl methacrylates (molecular weight distribution, physico-mechanical properties, resistance to the effects of aqueous media and physiological solution) in the form of copolymers of methyl methacrylate with methyl acrylate (MA) or butyl acrylate (BA) with the brand names Dacryl-4B, Dacryl-2M and Dacryl-4M (4% BA; 2 and 4% MA respectively) having a molecular weight of around 10"5. For comparison, block polymethyl methacrylate with a molecular weight of 3 x 10"6 was used. The results of experiments on the ageing of unirradiated and irradiated specimens in a heated store-room (t = 10 - 20"0C) and at high temperatures (90"0C) are also given. It is shown that irradiation with doses of 2.5 - 20 Mrad leads to radiolysis of the above copolymers, accompanied by destructive processes. Evidence of this is an increase in the ...
1974-12-09
International Nuclear Information System (INIS)
The authors present the results of an investigation of the effect of gamma radiation on the properties of low-molecular moulded polymethyl methacrylates (molecular weight distribution, physicomechanical properties, resistance to the effects of aqueous media and physiological solution) in the form of copolymers of methyl methacrylate with methyl (MA) or butyl acrylate (BA) with the brand names Dacryl-4B, Dacryl-2M and Dacryl-4M (4% BA; 2 and 4% MA respectively) having a molecular weight of around 10"5. For comparison, block polymethyl methacrylate with a molecular weight of 3 x 10"6 was used. The results of experiments on the ageing of unirradiated and irradiated specimens in a heated store-room (t = 10 - 20"0C) and at high temperatures (90"0C) are also given. It is shown that irradiation with doses of 2.5-20 Mrad leads to radiolysis of the above copolymers, accompanied by destructive processes. Evidence of this is an increase in the ...
1975-01-01
C-14 release and transport from a nuclear waste repository in an unsaturated medium
Energy Technology Data Exchange (ETDEWEB)
The release of {sup 14}C as {sup 14}CO{sub 2} from partly failed spent fuel containers has been analyzed by the flow of gases into and out of the containers. This flow of gases is driven by pressure differences, which are in turn caused by heating by the spent fuel. In this analysis, the timing and size of holes in the containers are assumed to be given. A better means of predicting the time distribution and sizes of penetrations in nuclear waste containers is needed. For the purposes of far-field transport calculations, we have adopted release rates that are shown to be bonding for the large range of hole sizes studied. The transport of released {sup 14}CO{sub 2} has been analyzed by transport in equivalent porous medium. The peak {sup 14}CO{sub 2} concentration in pore gas at 350 m above the repository does not depend on the time of hole occurrence, although the time of penetration obviously affects the arrival and duration of exposure to {sup 14}C. Nor does ...
1990-06-01
International Nuclear Information System (INIS)
Objective: To apply the obtained results from 3 stages of research in Chinese radiation protection field. Methods: Based on the identification of physical, chemical and biological qualities for element and its radionuclides under equilibrium condition, main application of these results in Chinese radiation protection field have been discussed by using reported methods in literature. Results: Based on developing elemental reference values of organs or tissues, whole body burdens and their distribution for Chinese Reference Man, discussed in the above 3 articles, current dietary elemental intakes of 42 elements have been updated, and related basis for certain important parameters of bio-kinetic model for use in radiation protection (for example, f_l, T_e and T_b) have been provided. The internal doses from primordial radionuclides and transfer coefficients of elements from environment into the critical organs of Chinese adult men have been ...
2007-08-01
166Ho-HA evaluation as therapeutic agent for rheumatoid arthritis treatment
International Nuclear Information System (INIS)
Aim: Rheumatoid arthritis is a limiting disease having, among its pathological features, the inflammation of synovial tissue with progressive and later destruction of the articulation. This leads to joint deformation and loss of its function, generating pain and reducing the mobility of the affected articulation. The aim was to evaluate "1"6"6Ho-Hydroxyapatite ("1"6"6 Ho-HA) as potential radiopharmaceutical for the symptomatic treatment of chronic and acute arthritis. Materials and Methods: Holmiun-166 was produced by irradiation of Ho_2O_3 at La Reina Research Reactor, Nuclear Chilean Energy Commission. Hydroxyapatite was in-house synthesized. Its labelling and quality controls follows the internationally accepted procedures. An antigen's arthritis was induced to eight New Zealand rabbits with the "1"6"6 Ho-HA radiochemical being administered thereafter in two dosage modalities (single and double). The compound therapeutic efficiency was evaluated based upon clinical improvement and ...
2002-09-01
X-ray dose enhancement effects
International Nuclear Information System (INIS)
A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.
Stochastic risk estimate for barium radiological examinations in Malaga (Spain)
International Nuclear Information System (INIS)
The aim of this research work has been the estimation of the stochastic risk for five barium examinations. The sample was the population attending the Radiological Service of the 'Nuestra Senora de la Victoria' University Hospital, who had been treated with some barium examinations, set in five different groups: oesophagus tract, oesophagus-gastric-duodenal tract, intestinal tract, enteroclysis and double enema. To estimate the stochastic risk, it is necessary to know the organ dose. This can be calculated from the dose-area product which allows us to determine the effective dose using software. The dose-area product is the most suitable quantity to measure in these types of examination. We have evaluated the contribution that each procedure provides to the genetically significant dose, somatically significant dose, collective effective ...
2000-01-01
Induction of bladder cancer in rats by fractionated intravesicular doses of N-methyl-N-nitrosourea.
UK PubMed Central (United Kingdom)
Experiments were conducted to determine the dose response of rat bladder urothelium to a range of different single and fractionated intravesicular doses of the carcinogen, N-methyl-N-nitrosourea (MNU)....Full Text Available
1982-03-01
International Nuclear Information System (INIS)
Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly different. Conclusion: The ...
2005-10-01
Effects of small doses of ionizing radiation on human health
Energy Technology Data Exchange (ETDEWEB)
The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).
1997-12-01
Effects of small doses of ionizing radiation on human health
International Nuclear Information System (INIS)
The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).
1997-01-01
UK PubMed Central (United Kingdom)
Purpose:To investigate the clinical usage of dose verification of Helical Tomotherapy plans by using 2D-array ion chambers, and to develop an efficient way to validate the dose delivered...Full Text Available
A two-stage sequential linear programming approach to IMRT dose optimization
UK PubMed Central (United Kingdom)
The conventional IMRT planning process involves two stages in which the first stage consists of fast but approximate idealized pencil beam dose calculations and dose optimization and the second...Full Text Available
2010-02-07
Energy Technology Data Exchange (ETDEWEB)
(3H)Quinuclidinyl benzilate binding to rat brain muscarinic receptors decreased after repeated exposure to soman, a potent organophosphorus cholinesterase inhibitor. The topographical distribution of this decrement was analyzed by quantitative receptor autoradiography. After 4 weeks of soman, three times a week, quinuclidinyl benzilate binding decreased to 67 to 80% of control in frontal and parietal cortex, caudate-putamen, lateral septum, hippocampal body, dentate gyrus, superior colliculus, nucleus of the fifth nerve, and central grey. Minor or no decreases were observed in thalamic or hypothalamic nuclei, reticular formation, pontine nuclei, inferior colliculus, nucleus of the seventh nerve, and cerebellum. Scatchard analyses of saturation curves using frontal cortex sections from soman-treated rats revealed a decrease in maximal quinuclidinyl benzilate binding from that in control rats and a return toward control levels by 24 days without any significant ...
1984-08-01
International Nuclear Information System (INIS)
[3H]Quinuclidinyl benzilate binding to rat brain muscarinic receptors decreased after repeated exposure to soman, a potent organophosphorus cholinesterase inhibitor. The topographical distribution of this decrement was analyzed by quantitative receptor autoradiography. After 4 weeks of soman, three times a week, quinuclidinyl benzilate binding decreased to 67 to 80% of control in frontal and parietal cortex, caudate-putamen, lateral septum, hippocampal body, dentate gyrus, superior colliculus, nucleus of the fifth nerve, and central grey. Minor or no decreases were observed in thalamic or hypothalamic nuclei, reticular formation, pontine nuclei, inferior colliculus, nucleus of the seventh nerve, and cerebellum. Scatchard analyses of saturation curves using frontal cortex sections from soman-treated rats revealed a decrease in maximal quinuclidinyl benzilate binding from that in control rats and a return toward control levels by 24 days without any significant ...
1984-01-01
Monte Carlo simulation of electron cones used in electron beam therapy
International Nuclear Information System (INIS)
A Siemens Mevatron KV2 accelerator installed at the Royal Adelaide Hospital employs cylindrical solid-walled electron cones for some electron collimation. The cones being used at present result in treatment fields that do not always conform with the International Electrotechnical Commission (IEC) Standards (particularly at high energies). The aim of this project was to simulate the existing cones using Monte Carlo methods in order to evaluate potential cone modifications required to overcome the field irregularities. Simulations were performed using the EGS4 (Electron Gamma Shower version 4, distribution II) Monte Carlo code installed on a DEC Alpha workstation at the University of South Australia. To rigorously simulate the existing electron cones it was necessary to also simulate various components within the treatment head of the linear accelerator. Results of simulations for existing cones were found to be consistent with experimental data. (obtained from Royal ...
1998-09-01
Energy Technology Data Exchange (ETDEWEB)
The space environment consists of a varying field of radiation particles including high-energy ions, with spacecraft shielding material providing the only major protection to astronauts from harmful exposure. Unlike low-linear energy transfer (LET) {gamma} or X-rays, the presence of shielding does not always reduce the radiation risks for energetic charged particle exposure, since the dose delivered by the charged particle increases sharply as the particle approaches the end of its range, a position known as the Bragg peak. The Bragg curve does not necessarily represent the biological damage along the particle traversal, and the 'biological Bragg curve' is dependent on the energy and the type of the primary particle, and may vary for different biological endpoints. Here we used a unique irradiation geometry to measure the biological response across the Bragg curve in human fibroblasts exposed to 577MeV/nucleon incident Fe ions in vitro. ...
2006-10-15
Ecological risk assessment of the east branch, Finniss River
International Nuclear Information System (INIS)
Quantitative ecological risk assessment (ERA) is a means whereby the risk posed by a toxicant in any system can be evaluated by comparing the distribution of its measured or modelled concentrations (water quality data (WQD)) with available information on the range of concentrations that are known to adversely affect biota within that, or similar, habitats (dose-response data (DRD)). Initially, the WQD are compared with regulatory criteria (e.g. ANZECC and ARMCANZ, 2000). If they fail this test, then, on the assumption that both data sets comprise subsets of the entire range of concentrations, probability density functions are derived assuming a standard distribution form a typically log-normal. In this paper, AQUARISK has been used to estimate the risk posed by copper in effluent from the Rum Jungle mine site, pre- and post-remediation, and the proportion of taxa likely to be affected in the East Branch (EB) of the Finniss ...
2002-03-01
Spacetime constraints on accreting black holes
International Nuclear Information System (INIS)
We study the spin dependence of accretion onto rotating Kerr black holes using analytic techniques. In its linear regime, angular momentum transport in MHD turbulent accretion flow involves the generation of radial magnetic field connecting plasma in a differentially rotating flow. We take a first principles approach, highlighting the constraint that limits the generation and amplification of radial magnetic fields, stemming from the transfer of energy from mechanical to magnetic form. Because the energy transferred in magnetic form is ultimately constrained by gravitational potential energy or Killing energy, the spin dependence of the latter allows us to derive spin-dependent constraints on the success of the accreting plasma to expel its angular momentum. We find an inverse relationship between this ability and black hole spin. If this radial magnetic field generation forms the basis for angular momentum transfer in ...
2009-06-15
We present high-precision time-series photometry of the classical delta Scuti star HD 144277 obtained with the MOST (Microvariability and Oscillations of STars) satellite in two consecutive years. The observed regular frequency patterns are investigated asteroseismologically. HD 144277 is a hot A-type star that is located on the blue border of the classical instability strip. While we mostly observe low radial order modes in classical delta Scuti stars, HD 144277 presents a different case. Its high observed frequencies, i.e., between 59.9c/d (693.9 microHz) and 71.1c/d (822.8microHz), suggest higher radial orders. We examine the progression of the regular frequency spacings from the low radial order to the asymptotic frequency region. Frequency analysis was performed using Period04 and SigSpec. The results from the MOST observing runs in 2009 and 2010 were compared to each other. The resulting frequencies were submitted to ...
2011-01-01
Radial keratoneuritis as a presenting sign in acanthamoeba keratitis.
The visual outcomes of Acanthamoeba keratitis, a rare cause of corneal infection, can be devastating. This paper reports two contact lens wearers with severe pain and photophobia who presented to the emergency room. Biomicroscopy revealed radial keratoneuritis in both individuals. Tissue culture on a nonnutrient agar plate with Escherichia coli overlay resulted in a heavy growth of Acanthamoeba. The inpatient treatment included 0.02% polyhexamethylene biguanide, chlorhexidine, neomycin/polymyxin B/bacitracin (Neosporin), and oral fluconazole, which successfully controlled the corneal infection and improvement in the best corrected visual acuity in both patients. Infection did not recur during the 12-month follow-up period. Acanthamoeba keratitis can present as radial keratoneuritis, mimicking other common corneal infections resulting in diagnostic and treatment delays. Early diagnosis and prudent treatment of Acanthamoeba keratitis are the keys ...
2011-07-01
On the origin of the Trojan asteroids Effects of Jupiter's mass accretion and radial migration
We present analytic and numerical results which illustrate the effects of Jupiter's accretion of nebular gas and the planet's radial migration on its Trojan companions. Initially, we approximate the system by the planar circular restricted three-body problem and assume small Trojan libration amplitudes. Employing an adiabatic invariant calculation, we show that Jupiter's thirty-fold growth from a $10 M_\\oplus$ core to its present mass causes the libration amplitudes of Trojan asteroids to shrink by a factor of about 2.5 to $\\sim 40%$ of their original size. The calculation also shows that Jupiter's radial migration has comparatively little effect on the Trojans; inward migration from 6.2 to 5.2 AU causes an increase in Trojan libration amplitudes of $\\sim4%$. In each case, the area enclosed by small tadpole orbits, if made dimensionless by using Jupiter's semimajor axis, is approximately conserved. Similar adiabatic invariant calculations ...
2000-01-01
Manufacturing of small scale W monoblock mockups by hot radial pressing
International Nuclear Information System (INIS)
In the frame of the European Technology R and D programme for International thermonuclear experimental reactor (ITER) and in the area of high heat flux plasma facing components (HHFC), representative small-scale mock-ups were manufactured and tested to compare different concepts and joining technologies (i.e. active brazing, hot isostatic pressing (HIPping), diffusion bonding, etc.). On the basis of the results obtained by thermal fatigue tests, the monoblock concept resulted to be the most robust one, particularly when the HIPping manufacturing technology is used. Within this programme, ENEA developed an alternative technique for manufacturing plasma-facing components with a monoblock geometry of the ITER machine. The basic idea of this technique, named hot radial pressing (HRP), is to perform a radial diffusion bonding between the cooling tube and the armour tile by pressurising the internal tube only and by keeping the process parameters ...
2003-09-01
Energy Technology Data Exchange (ETDEWEB)
In this work, the Calibration-Free approach for Laser-Induced Breakdown Spectroscopy (CF-LIBS) was applied for the first time to radially resolved spectra emitted by a laser-induced plasma. The radial profiles of plasma temperature and electron number density were used to calculate the local relative concentration of the elements of interest. We analyzed a set of profiles of the local spectral emission coefficient obtained previously by means of spatial deconvolution of the spectra from a copper-based alloy (Cu 93, Fe 5, Mn 1, Ni 1 wt.%) laser-induced plasma. A spatially integrated spectrum of the same plasma was also analyzed for comparison purpose. The relative abundance of the minor components Fe, Mn and Ni was calculated. The results obtained from the central region of the plasma were closer to the nominal concentrations than those obtained from the spatially integrated spectrum. However, an increasing deviation was observed towards the ...
2009-07-15
International Nuclear Information System (INIS)
In this work, the Calibration-Free approach for Laser-Induced Breakdown Spectroscopy (CF-LIBS) was applied for the first time to radially resolved spectra emitted by a laser-induced plasma. The radial profiles of plasma temperature and electron number density were used to calculate the local relative concentration of the elements of interest. We analyzed a set of profiles of the local spectral emission coefficient obtained previously by means of spatial deconvolution of the spectra from a copper-based alloy (Cu 93, Fe 5, Mn 1, Ni 1 wt.%) laser-induced plasma. A spatially integrated spectrum of the same plasma was also analyzed for comparison purpose. The relative abundance of the minor components Fe, Mn and Ni was calculated. The results obtained from the central region of the plasma were closer to the nominal concentrations than those obtained from the spatially integrated spectrum. However, an increasing deviation was observed towards the ...
2009-07-01
Determination of absorbed dose in a patient irradiated by beams of x or gamma rays in radiotherapy procedures
1976-01-01
Nucleon momentum distributions of 39(K), 40(Ca) and 48(Ca)
Energy Technology Data Exchange (ETDEWEB)
The proton momentum distributions of (39)K,(40)Ca and (48)Ca are calculated from the model-independent charge distributions obtained from analyses of electron elastic scattering and muonic atoms, and also from the charge distributions calculated from the single-particle potential method in the framework of the flucton model. The sensitivities of the momentum distribution to different regions of the charge distribution are determined. The analysis is extended to the neutron distributions using the single-particle potential method, and the differences between the proton and neutron momentum distributions are examined. The resulting momentum distribution in the case of (40)Ca is used for analyzing the quasielastic electron scattering.
1983-01-01
Operational reactor physics analysis codes (ORPAC)
International Nuclear Information System (INIS)
Full text: Research reactors have been playing a multi dimensional role in areas of nuclear fuel cycle programme, radio-isotope productions, neutron beam research etc. To ensure an efficient, smooth and safe operation of a nuclear research reactor, many reactor physics evaluations are required on routine basis. As part of reactor core management the important activities are maintaining core reactivity status, core power distribution, xenon estimations, safety evaluation of in-pile irradiation samples and experimental assemblies and assessment of nuclear safety in fuel handling/storage. In-pile irradiation requires a prior estimation of the reactivity load due to the sample, heating rate and the activity developed in it during irradiation. For the safety of the personnel handling irradiated samples the dose rate at the surface of shielded flask housing the irradiated sample should be less than 200 mR/Hr. Therefore, a proper shielding and ...
Activity patterns in elementary and high school students exposed to oxidant pollution
Energy Technology Data Exchange (ETDEWEB)
We investigated activity patterns of 17 elementary school students aged 10-12, and 19 high school students aged 13-17, in suburban Los Angeles during the oxidant pollution season. Individuals' relationships between ventilation rate (VR) and heart rate (HR) were calibrated' in supervised outdoor walking/jogging. Log VR was consistently proportional to HR; although calibrations' were limited by a restricted range of exercise, and possibly by artifact due to mouthpiece breathing, which may cause overestimation of VR at rest. Each subject then recorded activities in diaries, and recorded HR once per minute by wearing Heart Watches, over 3 days (Saturday-Monday). For each activity the subject estimated a breathing rate--slow (slow walking), medium (fast walking), or fast (running). VR ranges for each breathing rate and activity type were estimated from HR recordings. High-school students' diaries showed their aggregate distribution of ...
1992-07-01
Place matters: multilevel investigation of HIV distribution in Tanzania
UK PubMed Central (United Kingdom)
ObjectiveTo examine the extent to which the regional and neighborhood distribution of HIV in Tanzania is caused by the differential distribution of individual correlates...Full Text Available
2008-03-30
Wind turbulence estimates in a valley by coherent Doppler lidar
British Library Electronic Table of Contents (United Kingdom)
Abstract In this paper, the effect of several turbulence parameters during various flow conditions in Owens Valley, educed from coherent Doppler lidar data have been studied. Radial velocity structure functions are processed to estimate the turbulent kinetic energy (TKE) dissipation rate, integral length scale and velocity variance, assuming a theoretical model for isotropic wind fields. Corrections for turbulence measurements have been considered to address the complications due to inherent volumetric averaging of radial velocity over each range gate, noise of the lidar data, and the assumptions required to estimate effects of smaller scales of motion on turbulence quantities. Using data from the Terrain-induced Rotor Experiment (T-REX) in April-May 2006, vertical profiles of wind and tur...
2011-01-01
Rotary drill bit with rotary cutter
Energy Technology Data Exchange (ETDEWEB)
A rotary drill bit having a drill bit body and at least one trunnion projecting from the drill bit body and a rotary cutter supported on at least one radial roller bearing on the trunnion. The rolling elements of the bearing are guided on at least one axial end facing the drill bit body in an outer bearing race groove incorporated in the bore of the rotary cutter. The inner bearing race groove is formed on the trunnion for the rolling elements of the radial roller bearing. At least one filling opening is provided which extends through the drill bit body and trunnion and is essentially axially oriented having one terminal end adjacent the inner bearing race groove and at least one filler piece for sealing the opening.
1981-03-17
Pseudospin symmetry and the relativistic harmonic oscillator
A generalized relativistic harmonic oscillator for spin 1/2 particles is studied. The Dirac Hamiltonian contains a scalar, $S$, and a vector, $V$, quadratic potentials in the radial coordinate, as well as a tensor potential, $U$, linear in $r$. Setting either or both combinations $\\Sigma=S+V$ and $% \\Delta=V-S$ to zero, analytical solutions for bound states of the corresponding Dirac equations are found. The eigenenergies and wave functions are presented and particular cases are discussed, devoting a special attention to the non-relativistic limit and the case $\\Sigma=0$, for which pseudospin symmetry is exact. We also show that the case $U=\\Delta=0$ is the most natural generalization of the non-relativistic harmonic oscillator. The radial node structure of the Dirac spinor is studied for several combinations of harmonic oscillator potentials, and that study allows us to explain why nuclear intruder levels cannot be described in the ...
2004-01-01
Liquid crystal films on curved surfaces: An entropic sampling study
The confining effect of a spherical substrate inducing anchoring (normal to the surface) of rod-like liquid crystal molecules contained in a thin film spread over it has been investigated with regard to possible changes in the nature of the isotropic-to-nematic phase transition as the sample is cooled. The focus of these Monte Carlo simulations is to study the competing effects of the homeotropic anchoring due to the surface inducing orientational ordering in the radial direction and the inherent uniaxial order promoted by the intermolecular interactions. By adopting entropic sampling procedure, we could investigate this transition with a high temperature precision, and we studied the effect of the surface anchoring strength on the phase diagram for a specifically chosen geometry. We find that there is a threshold anchoring strength of the surface below which uniaxial nematic phase results, and above which the isotropic fluid cools to a ...
2010-01-01
CT-Expo - a novel program for dose evaluation in CT
International Nuclear Information System (INIS)
CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey on CT practice. Three different ...
2002-12-01
Total dose hardening of SIMOX buried oxides for fully depleted devices in rad-tolerant applications
International Nuclear Information System (INIS)
A total dose hardening treatment is applied to SIMOX buried oxides. Total ionizing dose radiation testing is performed on fully-depleted transistors fabricated on both hardened and non-hardened substrates. At 200 krads x-ray dose, the front gate shift is reduced from -0.7 to -0.2 V for FETs built on the hardened wafers.
1996-07-15
Survey of radiation doses to patients from the diagnostic use of X-rays
International Nuclear Information System (INIS)
The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).
1977-06-01
International Nuclear Information System (INIS)
... radiation effects human populations low dose irradiation neoplasms radiation
1980-01-01
International Nuclear Information System (INIS)
... organizations irradiation radiation doses radiation effects RADIATIONS.
1982-01-01
Software means of dose consumption planning
International Nuclear Information System (INIS)
Russian 2009 p. 118 Ukraine Mazilov, AV Stadnik, IA NSC 'Kharkiv
2009-02-23
Infrared stimulated luminescence-decay shape from NaCl as a function of radiation doses
Energy Technology Data Exchange (ETDEWEB)
Dose-dependent behavior of the infrared stimulated luminescence (IRSL) decay from NaCl has been studied experimentally using only one aliquot irradiated with a range of 2-200 Gy {beta}-radiation doses. It was observed that the maximum IRSL intensity has not changed by an increase in dose though the total intensity increased as expected. Considering the possible implications of our findings for dosimeter, the results were compared with the other studies and discussed.
2007-11-15
Influencing factors on ESR dose assessment in irradiated chicken legs
Energy Technology Data Exchange (ETDEWEB)
Electron spin resonance (ESR) dosimetry of irradiated chicken legs is based on the additive dose or the calibration curve methods. In both cases the practical assumption is made that the behaviour of the chicken bone does not depend on factors such as temperature during irradiation, storage conditions and dose rate. So the aim of the present work was to investigate to what extent the above mentioned factors could influence the post-irradiation dose assessment using the ESR technique. (author).
1996-12-31
International Nuclear Information System (INIS)
... pathological changes patients radiation protection radiotherapy diseases
1982-10-25
Energy Technology Data Exchange (ETDEWEB)
The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different.
1980-10-01
International Nuclear Information System (INIS)
The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different. (orig.).
1980-01-01
Effective dose equivalent in nuclear medicine investigations
International Nuclear Information System (INIS)
... radiation hazards hazards health hazards MEDICINE. SOMATICALLY
1984-05-07
Energy Technology Data Exchange (ETDEWEB)
Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. ...
1993-05-01
International Nuclear Information System (INIS)
Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. ...
1993-01-01
Bulgarian population exposure resulting from diagnostic nuclear-medicine applications
International Nuclear Information System (INIS)
... populations radiation doses RADIOACTIVE MATERIALS. SOMATICALLY
1980-10-26
Distribution Models for Optical Scintillation Due to ...
... Lincoln Laboratory Distribution Models for Optical Scintillation Due to Atmospheric Turbulence RR Parenti RJ Susiela Group 107 ...
2005-12-12
Mammary carcinogenesis in the rat after low-dose irradiation
International Nuclear Information System (INIS)
Carcinogenesis is now generally recognized to be an important detrimental effect in man after low dose irradiation. The carcinogenic action of ionizing radiation is clearly demonstrated after exposure to relatively high doses (in excess of 0.5 Gy) but for lower dose levels reliable direct observations are not available. With the introduction of special protocols for the performance of large scale screening programs by mammography the average absorbed dose in glandular tissue in the average breast can be restricted to a value of 3 mGy per mammogram. The risk for tumor induction after exposure to these low doses can never be established from human epidemiology. In order to investigate the risk of repeated exposure to small dose of ionizing radiation the induction of mammary tumors has been investigated in rats of the WAG/Rij strain after single and fractionated ...
1992-07-12
Donut-shaped high-dose configuration for proton beam radiation therapy
Energy Technology Data Exchange (ETDEWEB)
Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to ...
2005-01-01
Donut-shaped high-dose configuration for proton beam radiation therapy
International Nuclear Information System (INIS)
Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to ...
2005-01-01
An evaluation of low-dose single-slice helical CT in pulmonary CT scan
International Nuclear Information System (INIS)
Objective: To investigate the feasibility of low-dose single-slice helical CT in pulmonary CT scan and evaluate the clinical application. Methods: Thirteen cases were selected out of 132 cases, in which low-dose (50mAs) single-slice helical CT scan of chest was performed. This set of cases included 7 cases of multiple metastatic nodules; 3 of solitary pulmonary, nodule; and 3 of pulmonary patchy lesions. Regular dose (170mAs) CT scan was also performed on all those patients. The regular dose and low dose CT scan were compared on sensitivity of detecting the lesions; the performance in demonstrating the details of the abnormalities; and the capability of revealing the segmental bronchi as well. Results: The same number and size of the pulmonary nodules were revealed with scan modalities loaded with different doses. No significant difference in demonstrating the ...
2006-04-01
Wind or water driven wheel and bird scarer
Energy Technology Data Exchange (ETDEWEB)
The wind unit working wheel has 4 radial rectangular frames arranged in two vertical planes which are perpendicular to each other. In the planes limited by the frames, on loop hinges with limiting supports, there are flat blades. When the working wheel rotates under the influence of wind pressure, the blades automatically occupy a vertical or horizontal (wind vane) position depending on the direction of blade motion and the direction of wind velocity.
1984-01-04
Transition rates of electrons in superheavy elements
International Nuclear Information System (INIS)
Transition rates for electrons in the superheavy elements Z = 114, 126, 134, 145, 164 and 173 are calculated. K, L and M-shells are considerd as final states. The 2s - 1s stransition of multipolarity M1 is dominant for Z = 173 with a transition time of 10"-"1"8s. The radial expectation values and #sq root# are given. (orig.).
The general relativistic Poynting-Robertson effect
Energy Technology Data Exchange (ETDEWEB)
The general relativistic version is developed for Robertson's discussion of the Poynting-Robertson effect that he based on special relativity and Newtonian gravity for point radiation sources like stars. The general relativistic model uses a test radiation field of photons in outward radial motion with zero angular momentum in the equatorial plane of the exterior Schwarzschild or Kerr spacetime.
2009-03-07
The (2+1) Dirac Equations with $\\delta$ Potential
In this Letter the bound states of (2+1) Dirac equation with the cylindrically symmetric $\\delta (r-r_{0})$-potential are discussed. It is surprisingly found that the relation between the radial functions at two sides of $r_{0}$ can be established by an SO(2) transformation. We obtain a transcendental equation for calculating the energy of the bound state from the matching condition in the configuration space. The condition for existence of bound states is determined by the Sturm-Liouville theorem.
2001-01-01
Test particle moving in an interior static spherically symmetric geometry
Energy Technology Data Exchange (ETDEWEB)
The motion of a test particle moving in an interior static spherically symmetric geometry is investigated. The author concludes that an oscillatory motion with the test particle changing its motion from a free fall towards the center to an outward radial motion can not exist for any static interior spherically symmetric model.
1984-06-01
Scattering of scalar tardyons and tachyons from a Schwarzschild black hole
Energy Technology Data Exchange (ETDEWEB)
The Klein-Gordan equation in the background of the Schwarzschild curved space-time is considered and the scattering of radial tardyons and tachyons from a black hole is studied. It is shown that black holes of mass below 7x10/sup 14/g may contain bound states of tardyons of pion mass which will be unstable on account of the presence of an attractive r/sup -4/ term.
1982-10-01
Scattering of scalar tardyons and tachyons from a Schwarzschild black hole
International Nuclear Information System (INIS)
The Klein-Gordan equation in the background of the Schwarzschild curved space-time is considered and the scattering of radial tardyons and tachyons from a black hole is studied. It is shown that black holes of mass below 7x10"1"4g may contain bound states of tardyons of pion mass which will be unstable on account of the presence of an attractive r"-"4 term. (author).
International Nuclear Information System (INIS)
''Magnetic braking'' of the plasma toroidal rotation in the high confinement H mode by applied resonant, low m,n=1 static error fields is used in DIII-D [Nucl. Fusion 31, 875 (1991)] as an independent control to evaluate the E_rxB stabilization of microturbulence in the plasma core. In the core (#rho# approx-lt 0.9) of a tokamak, the radial electric field and its shear are dominated by toroidal rotation. The fundamental quantity for shear stabilization of microturbulence is shear in the velocity of the fluctuations v_p_e_r_p_e_n_d_i_c_u_l_a_r#approx#E_rxB/B#centre dot#B which in the core is v_p_e_r_p_e_n_d_i_c_u_l_a_r#approx#v_#phi#B_#theta#/ B_#phi#. With magnetic braking greatly decreasing the toroidal rotation and thus reducing the core radial electric field and shear, far infrared (FIR) measurements of density microturbulence show downshifting in frequency near #rho##approx#0.8 as a result of the reduced Doppler shift ...
Proton beam therapy for cancer in deep-seated organs
Energy Technology Data Exchange (ETDEWEB)
Radiation therapy has shown definite technical improvement due to application of proton beam irradiation. Clinical results of proton beam therapy also suggested enlargement of indication ranges in radial treatment and decrease of post radiation damages of the treatment of cancers in deep-seated organs. Inprovement of result in cancer therapy could be expected by this treatment technique in the future.
1988-10-01
A general theorem on the GBDT version of the B\\"acklund-Darboux transformation for systems rationally depending on the spectral parameter is treated and its applications to nonlinear equations are given. Explicit solutions of direct and inverse problems for Dirac-type systems, including systems with singularities, and for the system auxiliary to the $N$-wave equation are reviewed. New results on explicit construction of the wave functions for radial Dirac equation are obtained.
2009-01-01
Lorentz noninvariance without tachyons in the Schwarzschild field
Energy Technology Data Exchange (ETDEWEB)
Considering the radial motion of a test particle in the Schwarzschild field in the hypothesis of local rotational invariance, the authors discuss the conditions to be satisfied by a physically acceptable model of broken SO(3,1) symmetry, and shown in particular that to preserve causality a breaking, even infinitesimal, makes necessarily impenetrable the interior of the Schwarzschild sphere.
1987-06-01
Effect of rapid thermal annealing on radiation hardening of MOS devices
International Nuclear Information System (INIS)
The influence of RTA (Rapid Thermal Anneal) treatment on MOS radiation hardness is demonstrated and compared with classical furnace treatment. In the case of the RTA, the oxide trapped charge is found to depend on: (i) the anneal temperature as expected, data are in good agreement with a recently developed model of oxygen out-diffusion; (ii) the location across the wafer with a radial dependence, results could be related to stress induced by thermal gradient.
1995-07-17
Compton scatter tomography and its inversion using a few projections
Energy Technology Data Exchange (ETDEWEB)
Compton scatter tomography utilizes the electronic collimation characteristics available through the Compton scattering angle-energy correlation to obtain tomographic images. In this work we present particular aspects of the technique, which are relevant to the inverse radiation transport problem of reducing marginal projection data to radial two-phase flow regime maps. The results indicate a viable technique for the tomographic imaging of tow-phase flow using practical source strengths and reasonably few detectors.
1988-01-01
A somatic dose index for diagnostic radiology
International Nuclear Information System (INIS)
Irradiation of the human body in diagnostic X-ray procedures results in different absorbed doses in the various body organs. A somatic dose index in formulated by applying the relative sensitivity of the human to each of the most important somatic effects and utilizing the absorbed dose in the affected organs. This quantity is used to convey a cumulative somatic impact and is computed for common radiographic views in diagnostic radiology as a function of beam quality for a nominal IR entrance exposure. Using typical X-ray beam qualities and exposures, the frequency of the various radiographic views that make up an examination and the frequencies of the various examinations in the national population, illustrative examples of the application of the somatic dose index are presented. (author).
1978-01-01
Study of silicon damage caused by ultra-low energy boron implantation
International Nuclear Information System (INIS)
Ultra-shallow junction formation in deep submicron Si devices is limited by anomalous diffusion of the dopant, which is related to the release of interstitials from defect clusters formed during the implantation of energetic ions or the subsequent annealing. The work described in this dissertation is concerned with the effects of low energy B ion implantation, especially damage formation, clustering and its annealing. After a review of the stopping and ranges of energetic ions in Si, the formation of implant damage, in particular of point defects, their migration, agglomeration and annihilation, including the involvement of dopant ions, is considered. A description of the Salford ultra low energy implanter is given and the main analysis technique, medium ion energy scattering (MEIS) reviewed. Additional analytical techniques used, such as secondary ion mass spectrometry (SIMS), 4-point probe and cross section transmission microscopy (XTEM) as well as TRIM simulation are briefly ...
In vitro and in vivo analysis of pegulated Avidin
Energy Technology Data Exchange (ETDEWEB)
Full text: In 1995, we demonstrated the use of pretargetting three steps method and biotinylated tetracycline using radiolabelled {sup 99m}Tc-DTPA-biocytinamide for the detection of tumour cells in (C57B1/6 x BALB/C) F1 mice with E-3 thymoma. The three steps were (1) IP injection of biotinylated-tetracycline conjugate (1:1) ratio, (2) 96 hours later Avidin/Streptavidin was injected, and (3) 24 hours after (2), {sup 99m}Tc-biocytinamide -cDTPA was injected. Mice were sacrificed 16/24 h after (3) by cervical dislocation. Biodistribution of radioactivity tumour to blood, liver, bone were T:B1= 15.0, T:Li= 5.08, T:Bo=15.0. The percentage of injected dose per g was T= 3.15% and B1= 0.21%. To prolong circulation of Avidin and therefore its uptake into tumour, Avidin was covalently bound to polyethylene-glycol (PEG20 KD) at the molar ratio of PEG:Avidin 100:1 and 400:1. The pegulated Avidin was then cleared from the circulation using Dextran-70-Biotin. The ...
1997-09-01
Project SAFE. Update of the SFR-1 safety assessment. Phase 1. Appendix A1: Inventory
Energy Technology Data Exchange (ETDEWEB)
One of the aims in the safety assessment of SFR-1 is to estimate the release to the environment. In order to make these calculations there is a need to describe the inventory in greater detail. The new computerised database of waste in SFR-1 gives a good possibility to achieve this. The aim for project SAFE is to make both conservative and realistic radionuclide transport calculations. To achieve this goal there must be two inventories. The conservative inventory is the inventory used in the design of the repository, which in most parts is identical with the limits in the licence for SFR-1. There is a great interest to have good estimates of the volumes of the different waste types. A thorough prognosis should be made in 1999, but until then the latest one from 1995 could be used in the calculations. The total (actual) inventory of nuclides is calculated from the measurements of the easy-to-measure nuclides since, in principle, all hard-to-measure nuclides are calculated by correlation ...
1998-10-01
Individual Radiation Protection Monitoring in the Marshall Islands: Rongelap Atoll (2002-2004)
Energy Technology Data Exchange (ETDEWEB)
The United States Department of Energy (U.S. DOE) has recently implemented a series of strategic initiatives to address long-term radiological surveillance needs at former U.S. nuclear test sites in the Marshall Islands. The plan is to engage local atoll communities in developing shared responsibilities for implementing radiation protection monitoring programs for resettled and resettling populations in the northern Marshall Islands. Using the pooled resources of the U.S. DOE and local atoll governments, individual radiological surveillance programs have been developed in whole body counting and plutonium urinalysis in order to accurately assess radiation doses resulting from the ingestion and uptake of fallout radionuclides contained in locally grown foods. Permanent whole body counting facilities have been established at three separate locations in the Marshall Islands including Rongelap Atoll (Figure 1). These facilities are operated and maintained by ...
2006-01-17
Whole-body counting in the Marshall Islands
Energy Technology Data Exchange (ETDEWEB)
In 1978 the Marshall Islands Radiological Safety Program was organized to perform radiation measurements and assess radiation doses for the people of the Bikini, Enewetak, Rongelap and Utirik Atolls. One of the major field components of this program is whole- body counting (WBC). WBC is used to monitor the quantity of gamma- emitting radionuclides present in individuals. A primary objective of the program was to establish {sup 137}Cesium body contents among the Enewetak, Rongelap and Utirik populations. {sup 137}Cs was the only gamma-emitting fission radionuclide detected in the 1,967 persons monitored. {sup 137}Cs body burdens tended to increase with age for both sexes, and were higher in males. The average {sup 137}Cs dose Annual Effective Dose for the three populations was as follows: For Enewetak, the dose was 22{+-}4 {mu}Sv. For Utirik, the dose was 33{+-} 3 {mu}Sv. Since 1985 ...
1991-01-01
The somatically significant dose, SSD, and analog of the GSD, the genetically significant dose
International Nuclear Information System (INIS)
The medical applications of radiation comprise three main fields namely: Diagnostic Radiology, Radiotherapy and Nuclear Medicine. With the new weighting factors of ICRP (IC91a) the effective dose due to medical applications can be established. I is common to separate the effective dose into the genetic part and the somatic part, SED. In dealing with gonad doses it is important to account for the age of the person at the time of exposure as this will influence the number of children still to be expected from that person. The resulting dose will then be called the genetically significant dose, GSD. In a similar fashion this age factor will be important in considering the chance of tumor induction. The age of patients differs considerably from the average age of the general population. This age difference has to be accounted for if a comparison is to be made with other sources of ...
1991-11-01
Safety assessment for clearance of radioactive metal wastes from nuclear facility
Energy Technology Data Exchange (ETDEWEB)
Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 {mu}Sv/y, collective dose: 1 man{center_dot}Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 {mu}Sv per year and 0.166 man{center_dot}Sv per year about H-beam, and 158 {mu}Sv per year and 0.468 man{center_dot}Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance ...
2003-10-01
Safety assessment for clearance of radioactive metal wastes from nuclear facility
International Nuclear Information System (INIS)
Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 #mu#Sv/y, collective dose: 1 man#centre dot#Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 #mu#Sv per year and 0.166 man#centre dot#Sv per year about H-beam, and 158 #mu#Sv per year and 0.468 man#centre dot#Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance ...
2003-10-01
Medical irradiation and the use of the 'effective dose equivalent' concept
International Nuclear Information System (INIS)
By applying the linear-dose effect relation, the weighting factors for total risks recommended by IRCP can be transformed to weighting factors for somatic effects. Another weighting factor Msub(s) has to be used which takes into account the dependence of the latent period for occurrence of malignant disease and the variation of the incidence with time. On this basis a somatically significant dose equivalent can be defined as 'the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by the various individuals', and an approximation has been derived for this. Tables are presented of the somatic effective dose equivalents calculated for different x-ray examinations for various organs and tissues. The S.E.D. equivalents have also been calculated for ...
1980-03-01
Dosimetry limitations and a dose correction methodology for step-and-shoot IMRT
Energy Technology Data Exchange (ETDEWEB)
For the step-and-shoot intensity-modulated radiation therapy (IMRT) technique, the combination of high dose rate, multiple beam segments and low dose per segment can lead to significant differences between the planned dose and the dose delivered to the patient. In this technique, a dose delivery inaccuracy known as the 'overshoot' effect is caused by the dose servo control system. This typically occurs in the first and last beam segments and causes an over- and underdose, respectively. Some dose positional error in the segment sequence is also possible there. Commercial ionization chambers (RK-type) and radiographic Kodak films were used for the measurements. The reported results were obtained using the Pinnacle{sup 3}-V6.2 treatment planning system and a Varian Clinac 21 EX linear accelerator equipped with a 120-leaf ...
2006-02-07
The development of thyroid dose assessment software for nuclear or radiological emergency
International Nuclear Information System (INIS)
Objective: To develop software for assessment of dose to thyroid gland in emergencies resulting in the release of radioiodine. Methods: Based on procedures for thyroid monitoring and dose assessment introduced in IAEA publications (IAEA-TECDOC-1092 and EPR-MEDICAL-2005), a software was developed with Visual Basic 6.0 program to computerized the methods of thyroid dose estimation. Results: The intake of radioiodine and committed equivalent dose to thyroid could be estimated rapidly and accurately with the present software. Conclusion: The present software provide a practical and rapid tool for estimating thyroid doses received in emergencies resulting in the release of radioiodine by emergency workers and members of public, which is necessary for recommendation of further actions. (authors)
2006-12-01
Energy Technology Data Exchange (ETDEWEB)
When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).
1991-08-01
International Nuclear Information System (INIS)
When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).
1991-01-01
Influence of the X-ray radiation on the lifetime of carriers in the p-n junctions of Si and Ge
International Nuclear Information System (INIS)
Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of lifetime of the charge carriers with the increase of X-ray radiation dose.
Effect of Nordic diets on ECOSYS model predictions of ingestion doses
British Library Electronic Table of Contents (United Kingdom)
The ECOSYS model is used to estimate ingestion dose in the ARGOS and RODOS decision support systems for nuclear emergency management. It is recommended that nation-specific values for several parameters are used in the model. However, this is generally overlooked when the systems are used in practice. We have estimated first year ingestion doses in two scenarios with wet and dry deposition of 137Cs, using the ECOSYS model. We calculated doses for each country using national dietary data while keeping all other parameters at their default values. These dose calculations were then used to estimate the variation in ingestion doses resulting from the variation in the diets only. The dietary data demonstrated that the average consumption of milk, meat and vegetables varied by a factor of 2-4 am...
2010-01-01
Dose enhancement in bone in electron beam therapy
Energy Technology Data Exchange (ETDEWEB)
This study investigated dose to bone tissue in electron beam therapy. Measurements were made using films and thermoluminescent dosimeters in a polystyrene phantom containing bone inhomogeneity for 15-MeV, 12-MeV, and 9-MeV electron beams. An increase in dose of approximately 18%, 12%, and 11%, for the three electron energies respectively, relative to the dose in polystyrene, was found for bone material having an electron density (relative to water) of 1.73. Measurements were also made using films for 15- and 9-Mev electrons in a phantom with a mandibular bone and teeth. A dose enhancement in bone of approximately 10% and 7%, respectively, for the two energies was found in the phantom where the electron density of bone was about 1.60. These results suggest that injury to bone is possible in those clinical situations where high doses of electrons are used for therapy.
1984-05-01
Dose enhancement in bone in electron beam therapy
International Nuclear Information System (INIS)
This study investigated dose to bone tissue in electron beam therapy. Measurements were made using films and thermoluminescent dosimeters in a polystyrene phantom containing bone inhomogeneity for 15-MeV, 12-MeV, and 9-MeV electron beams. An increase in dose of approximately 18%, 12%, and 11%, for the three electron energies respectively, relative to the dose in polystyrene, was found for bone material having an electron density (relative to water) of 1.73. Measurements were also made using films for 15- and 9-Mev electrons in a phantom with a mandibular bone and teeth. A dose enhancement in bone of approximately 10% and 7%, respectively, for the two energies was found in the phantom where the electron density of bone was about 1.60. These results suggest that injury to bone is possible in those clinical situations where high doses of electrons are used for therapy.
Analysis of photon beam exit dose using photon point kernels
International Nuclear Information System (INIS)
The Monte Carlo method is used to analyse the dose fall-off at the exit surface of a megavoltage photon beam. The convolution/superposition method of dose calculation using Monte-Carlo-generated homogeneous photon kernels is shown to be in error for exit dose calculation. Instead, photon kernels that incorporate modelling of the exit surface were generated, also using Monte Carlo, to analyse the problem, and the calculated dose fall-off using these kernels agrees well with measured data. In addition, the physics underlying the characteristics of the dose fall-off is analysed based on complete Monte Carlo modelling. Practical improvements to the convolution/superposition method are suggested. (Author).
Reduced "9"9"mTc labelled NCA-95/CEA-antibody uptake in liver due to gentle antibody reconstitution
International Nuclear Information System (INIS)
The influence of reconstituting a murine monoclonal IgG_1 antibody kit with pertechnetate Tc99m on antibody distribution in the liver, spleen and sternal bone marrow of patients was examined. The "9"9"mTc-labelled antibody used is directed against non-specific cross-reacting antigen (NCA-95) and carcinoembryonic antigen (CEA) and has been successfully applied for imaging tissue inflammation and bone marrow scanning. Radioactivity uptake was determined in the liver, spleen, bone marrow and a precordial background region in a consecutive series of 25 patients, examined with an antibody preparation, routinely radiolabelled according to the manufacturer's recommendations and in 14 patients, in whom the antibody was reconstituted with special care, avoiding bubble formation and dropping of buffer into the antibody-containing vial. Gentle compared with routine antibody reconstitution caused a highly significant reduction of the antibody uptake in the liver, as determined ...
Molecular dynamics studies of silicon ion implantation
Energy Technology Data Exchange (ETDEWEB)
Results are presented of molecular dynamics (MD) studies of 1-10 keV displacement cascades in silicon. At these energies, the simulations couple directly to experimental observations of low energy implantation in silicon for shallow junction formation. The simulations are performed with the Stillinger-Weber potential for silicon in computational cells with up to 3.5x10{sup 5} atoms. The author employs periodic boundary conditions in the [100] and [010] directions and a free surface on the top (001) plane. The author discusses the results in terms of the structural evolution and the dynamics of the cascade zones. For sufficiently high energy recoils (>2 KeV), the cascades produce locally molten zones that result in the formation of amorphous silicon pockets upon recrystallization. Frenkel pairs are also produced during the cascade, although their number is very small (less than 10% of the binary collision predictions). Upon annealing of the resulting damage microstructure at 1100K ...
1994-12-31
International Nuclear Information System (INIS)
One rationale proposals to increase the efficiency of PDT is to combine photo-sensitization with other treatment modalities, including modulation of arachidonic acid metabolism. In combine treatment we examined the effects of 48 h and 24 h pre-treatment of cells with 5- lipoxygenase inhibitor MK-886 prior to photoactivation of hypericin on cell cycle distribution and DNA synthesis. All parameters were examined 24 hours after hypericin activation. Pre-treatment of HT-29 with 5-lipoxygenase inhibitor MK-886 followed by PDT resulted in most significant effects on cell cycle perturbations. Administration of MK-886 alone as well as combination of low doses MK-886 with hypericin induced S phase accumulation. Increasing of MK-886 concentration induced massive changes in the cell cycle progression. Pre-treatment of HT-29 cells with MK-886 alone (15 #mu#M; - 48 h) caused accumulation of cells in S-phase (58 % in S-phase and 36 % in G_0/G_1 phase). ...
2006-05-01
International Nuclear Information System (INIS)
Apricot fruits usually harvested relatively mature but hard enough to withstand-post harvest handling through the marketing chain. These fruits have considerably lower edible quality than tree-ripened fruit. Fruit quality can be improved by delaying harvest least until physiological maturation is completed on the tree (Bonghi et al. 1999) Apricots containing 11% soluble solids concentration, or higher are in high demand by consumers, as fruit have developed considerable taste, aroma and handling for long distance markets. (Kader, 1999). These fruit will be highly perishable, so rapid cold storage to the lowest safe temperature and supplementary treatments (Mc Donald et al, 1999) such as irradiation with the recommend doses (Sillano et al, 1994) or pre-storage heat treatments will be necessary to retard ripening (mainly softening) during 1-2 weeks post harvest life necessary for distribution to distant markets (Mc Donald et al 1999). Therefore, ...
2003-03-01
International Nuclear Information System (INIS)
Natural radioactive materials under certain conditions can reach hazardous radiological levels. The natural radionuclide ("2"3"8U, "2"3"2Th, "4"0K) contents of rock samples at various locations in the North Tushki area were investigated using gamma-spectrometric analysis. Estimates of the measured radionuclide content have been made for the absorbed dose rate of gamma radiation. The equivalent radium (R_e_q) and the external hazard index (H_e_x) which resulted from the natural radionuclides in soil are also calculated and tabulated. The studied samples have been collected from various rock exposures in the North Tushki area. The distribution of major oxides, U and Th were studied. It is found that the enrichment and depletion of the major oxides are mainly due to the effect of hydrothermal alteration, which caused mobility of some major oxides, which increases some elements and decreases others. It is important to mention that the study area is ...
2002-09-01
International Nuclear Information System (INIS)
Nuclear Reaction Analysis (NRA) with deuteron ion beams has been used to probe for ion implanted nitrogen and carbon with high sensitivity in zinc oxide and silicon single crystals. The ion implanted N was measured using 1.4 MeV deuteron ion beams and was found to be in agreement with calculated values. The limit of detection for N in ZnO is 8x1014 ions cm-2. Raman measurements of the ion implanted samples showed three additional modes at 275, 504, and 644 cm-1 compared to the un-implanted ZnO crystals. The NRA and Raman results provided information on the N concentration, depth distribution, and structural changes that occur in dependence on the nitrogen ion fluences. The deuterium induced 12C(d,p)13C reaction was used to measure the carbon impurity/dose in ion implanted silicon. It was found that the use of a large cold shield (liquid nitrogen trap) in the ion implanter chamber greatly reduces the amount of carbon impurity on the surface of ...
2008-11-03
Challenges in environmental radiological surveillance around nuclear facilities
International Nuclear Information System (INIS)
To accomplish the environmental radiological surveillance need of India's ambitious nuclear power programme, Health Physics Division is infusing new technologies and improved analytical techniques for day to day measurements of various radionuclides in different environmental matrices. It is essential to have techniques for measuring the concentration of radionuclides just above the background level since the discharges from the nuclear facilities are very low i.e. in the range of 5-10% of the prescribed discharge limits by the regulatory bodies. In view of developing ultra-sensitive techniques, the aim of ongoing programmes of the division is to meet the challenges of measuring ultra trace level of radioactivity by adopting state of art new instrumentation and improved sample processing techniques. This will allow us to measure the lowest level of radioactivity (3H, 90Sr, 137Cs, 239+240Pu, etc.) in the environment and thereby estimating the lowest doses to the ...
2007-06-05
Accelerators for proton and heavy ion radiotherapy
Energy Technology Data Exchange (ETDEWEB)
The construction of Heavy Ion Medical Accelerator in Chiba (HIMAC) at the National Institute of Radiological Sciences was completed in December 1993. HIMAC consists of an injector linac, two synchrotron rings, a high energy beam transport system and a beam irradiation system. Its accelerator parameters are based on the medical requirement, and helium, carbon, neon, silicon and argon were selected as the accelerated ion species. It has 3 therapy rooms (A{approx}C). Room A has a vertical irradiation system, Room C horizontal and Room B both vertical and horizontal. Two rings can supply beams independently to the vertical and horizontal irradiation systems. Clinical trial started on June 21 1994, after several basic biological and physics experiments lasting about 2 months. Cancer is the top cause of death in Japan since 1981, and people expect good treatment results at HIMAC. Proton and heavy ion radiotherapy has the advantage of dose ...
1995-03-01
ANALYSIS OF ACCELERATOR BASED NEUTRON SPECTRA FOR BNCT USING PROTON RECOIL SPECTROSCOPY
Energy Technology Data Exchange (ETDEWEB)
Boron Neutron Capture Therapy (BNCT) is a promising binary treatment modality for high-grade primary brain tumors (glioblastoma multiforme, GM) and other cancers. BNCT employs a boron-10 containing compound that preferentially accumulates in the cancer cells in the brain. Upon neutron capture by {sup 10}B energetic alpha particles and triton released at the absorption site kill the cancer cell. In order to gain penetration depth in the brain Fairchild proposed, for this purpose, the use of energetic epithermal neutrons at about 10 keV. Phase I/II clinical trials of BNCT for GM are underway at the Brookhaven Medical Research Reactor (BMRR) and at the MIT Reactor, using these nuclear reactors as the source for epithermal neutrons. In light of the limitations of new reactor installations, e.g. cost, safety and licensing, and limited capability for modulating the reactor based neutron beam energy spectra alternative neutron sources are being contemplated for wider implementation of this ...
1998-11-06
Energy Technology Data Exchange (ETDEWEB)
To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca{sub 2}SO{sub 4}:Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let ...
2006-07-01
International Nuclear Information System (INIS)
International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the absorbed ...
2007-08-01
Energy Technology Data Exchange (ETDEWEB)
A general expression for the current-density distribution of a focused-ion beam (FIB) in the chromatic-aberration region is set up in the form of a definite integral. With the experimentally obtained ion-energy distribution of a liquid-metal ion source, its contribution to the FIB current-density distribution is estimated. Calculated results explain the wide-exponential tail of a FIB.
1987-09-01
International Nuclear Information System (INIS)
A general expression for the current-density distribution of a focused-ion beam (FIB) in the chromatic-aberration region is set up in the form of a definite integral. With the experimentally obtained ion-energy distribution of a liquid-metal ion source, its contribution to the FIB current-density distribution is estimated. Calculated results explain the wide-exponential tail of a FIB.
UK PubMed Central (United Kingdom)
For intensity modulated radiation treatment (IMRT) dose reconstruction, multileaf collimator (MLC) log files have been shown applicable for deriving delivered fluence maps. However, MLC log files are...Full Text Available
2008-11-01
UK PubMed Central (United Kingdom)
1. The antihypertensive efficacy and tolerability of a low dose combination of the angiotensin converting enzyme inhibitor ramipril (2.5 mg) and the extended release formulation of the dihydropyridine...Full Text Available
1993-10-01
Somatic and genetic effects of small doses of ionizing radiations in man
International Nuclear Information System (INIS)
Estimations on the somatic and genetic effects of small doses of ionizing radiations in Man have been proposed by the Advisory Committee on the Biological Effects of Ionizing Radiation, set up by the U.S. National Academy of Sciences. They have been published in an important report, issued in 1972, from which we briefly analyze here the Chapter dealing with the somatic effects. Small doses of raditions are expected to promote only carcinogenic effects. After a rapid survey of the human experience on which the estimations are based, as regards the latent period of cancers, the plateau region (period of high risk) and the absolute and relative risk expressed per rem, per 10"6 persons, per year, for leukaemia (having the highest risk) and for the ''other cancers''. These estimations were obtained by linear extrapolation to the 1 rem level from observations made after irradiation at relatively high dose levels and much higher ...
1976-01-01
Single-dose pharmacokinetics of ceftriaxone in healthy Chinese adults.
UK PubMed Central (United Kingdom)
The pharmacokinetics of ceftriaxone were investigated in six healthy mainland Chinese adults (four males and two females). A single 1.0-g dose was administered intravenously or intramuscularly in a...Full Text Available
1985-02-01
Risk of cancer after low doses of ionising radiation: retrospective cohort study in 15 countries
UK PubMed Central (United Kingdom)
Objectives To provide direct estimates of risk of cancer after protracted low doses of ionising radiation and to strengthen the scientific basis of radiation protection standards for environmental,...Full Text Available
2005-07-09
UK PubMed Central (United Kingdom)
AimsTo assess the tolerability and pharmacokinetic profile of single and repeat doses of the oral matrix metalloproteinase inhibitor marimastat in healthy male volunteers.Full Text Available
1998-01-01
Range and modulation dependencies for proton beam dose per monitor unit calculations
UK PubMed Central (United Kingdom)
Calculations of dose per monitor unit (D∕MU) are required in addition to measurements to increase patient safety in the clinical practice of proton radiotherapy. As in conventional photon and...Full Text Available
2009-02-01
Radiation risks for medical applications
International Nuclear Information System (INIS)
The achievements made in the field of radiation protection over the past 20 years are outlined. Risk analysis as applied to medicine is considered and genetic significant doses, genetic risks, somatic effective doses and somatic risks are discussed. (C.F.).
1980-05-31
UK PubMed Central (United Kingdom)
Low dose methotrexate has been used effectively for various rheumatic and non-rheumatic diseases. Three cases of Pneumocystis carinii pneumonia occurring during treatment of rheumatoid arthritis with...Full Text Available
1991-03-01
UK PubMed Central (United Kingdom)
BackgroundThe aim of this study was to compare and to validate different dose calculation algorithms for the use in radiation therapy of small lung lesions and to optimize the treatment...Full Text Available
UK PubMed Central (United Kingdom)
The reference medium for brachytherapy dose measurements is water. Accuracy of dose measurements of brachytherapy sources is critically dependent on precise measurement of the source–detector...Full Text Available
2010-01-01
Milk residues and performance of lactating dairy cows administered high doses of monensin
UK PubMed Central (United Kingdom)
AbstractMilk residues and performance were evaluated in lactating cows that were fed up to 10 times the recommended dose of monensin. Following an acclimatization period of 14 d, during...Full Text Available
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this report is to summarize the assumptions, dose factors, consumption rates, and methodology used to evaluate potential radiation doses to persons who may eat contaminated wildlife or contaminated plants collected from the Hanford Site. This report includes a description of the number and variety of wildlife and edible plants on the Hanford Site, methods for estimation of the quantities of these items consumed and conversion of intake of radionuclides to radiation doses, and example calculations of radiation doses from consumption of plants and wildlife. Edible plants on the publicly accessible margins of the shoreline of the Hanford Site and Wildlife that move offsite are potential sources of contaminated food for the general public. Calculations of potential radiation doses from consumption of agricultural plants and farm animal products are made routinely and ...
1990-10-01
International Nuclear Information System (INIS)
For the risk estimate of fatal malignancies, an effective dose was proposed on the basis of the assumption that the risk should be equal whether the whole body irradiated uniformly or whether there is non-uniform irradiation. The effective dose was defined by the product of organ or tissue doses and a weighting factor representing the proportion of risk factor for a fatal malignancy resulting from organ or tissue irradiation to the total malignant factor. The risk of malignancies can be derived by multiplying the malignant significant factor by the product of the risk factor and the effective dose. For the genetic risk, a significant factor was a relative child expectancy and organ or tissue doses were gonad doses. And, for the leukemogenic risk, a significant factor was the leukemia significant factor and organ or tissue dose was mean bone ...
1980-01-01
Metabolism of iodomethane in the rat
UK PubMed Central (United Kingdom)
1. The LD50 of iodomethane orally administered to rats is 76mg./kg. body wt. but repeated daily doses of 30–50mg./kg. body wt. are without effect. 2. Oral doses of iodomethane to...Full Text Available
1966-01-01
Low-Dose, Off-Label Drotrecogin Alfa (Xigris) In Severe Sepsis
UK PubMed Central (United Kingdom)
Objective:In this article, we describe a successful low-dose, off-label usage of drotrecogin alfa (Xigris), given at 18 mcg/kg per hour, in a patient with severe sepsis who had an...Full Text Available
2008-08-01
UK PubMed Central (United Kingdom)
ObjectiveTo assess the efficacy and safety of low dose adrenaline injected subcutaneously to prevent acute adverse reactions to polyspecific antivenom serum in patients admitted...Full Text Available
1999-04-17
Long-term effects of inhaled uranyl nitrate in rats
International Nuclear Information System (INIS)
Rats were exposed to aerosols of "2"3"3U and "2"3"2U nitrate in a study of the long-term biological effects. Preliminary radiation dose estimates show lung > skeleton > kidney in each dose group.
1977-05-01
Isochron measurements of naturally irradiated K-feldspar grains
International Nuclear Information System (INIS)
The equivalent doses of K-feldspar grains in a range of grain sizes from 90 to 250#mu#m diameter were measured using a single-aliquot regenerative-dose protocol for the infrared stimulated luminescence (IRSL) signals for two samples of desert sand. The equivalent doses for each sample were compared with that for the 125-150#mu#m grains of quartz from the same samples. The results suggested that the K-feldspar equivalent doses were underestimated because of anomalous fading. Measurements of the decay of the IRSL signals following laboratory irradiation for these two samples, and an additional one from a previously published isochron study, showed anomalous fading during the period of laboratory storage. The decay rate was about 3% per decade for all samples and was independent of the grain size used. Using plots of equivalent doses for K-feldspars as a function of their calculated ...
2007-09-01
Inhibition of exercise-induced asthma by nifedipine: a dose-response study.
UK PubMed Central (United Kingdom)
1. The effect of three single doses of nifedipine on exercise-induced asthma has been examined in 11 asthmatic subjects. 2. On four separate days patients undertook 6 min of exercise on a treadmill...Full Text Available
1987-10-01
Induction of tumors by screening mammography
International Nuclear Information System (INIS)
Somatic radiation doses are recognized to be possible factors of carcinogenesis. In correctly performed mammography, however, even as screening test, the radiation dose does not reach such an order of magnitude that the benefit of the procedure as to prevention of breast cancer is called into question.
1983-01-01
Fluence-convolution broad-beam (FCBB) dose calculation
International Nuclear Information System (INIS)
IMRT optimization requires a fast yet relatively accurate algorithm to calculate the iteration dose with small memory demand. In this paper, we present a dose calculation algorithm that approaches these goals. By decomposing the infinitesimal pencil beam (IPB) kernel into the central axis (CAX) component and lateral spread function (LSF) and taking the beam's eye view (BEV), we established a non-voxel and non-beamlet-based dose calculation formula. Both LSF and CAX are determined by a commissioning procedure using the collapsed-cone convolution/superposition (CCCS) method as the standard dose engine. The proposed dose calculation involves a 2D convolution of a fluence map with LSF followed by ray tracing based on the CAX lookup table with radiological distance and divergence correction, resulting in complexity of O(N"3) both spatially and temporally. This simple algorithm is orders ...
2010-12-07
Epidemiological survey of the effects of low level radiation dose: a comparative assessment
Energy Technology Data Exchange (ETDEWEB)
This volume presents the collations tables of a six volume comparative epidemiological survey of the effects of low level radiation dose. Data are collated for the effects observed in the following irradiated groups:- Preconception irradiation, intra-uterine irradiation, childhood irradiation, adult irradiation. (UK).
1993-10-01
International Nuclear Information System (INIS)
The genetically significant dose (GSD) is an index variable which exclusively allows to describe the genetic risk in the progeny of a population due to the application of ionizing radiation and radioactive substances in one part of this population. It may result in wrong interpretation of population exposure at increasing incidence of examinations in a population involving ionizing radiation and radioactive drugs at simultaneously increasing application of alternative methods in children and adolescents owing to the fact that it indicates a downward trend although somatic exposure of this population has increased. Therefore, it is recommended to state both the GSD and the level of somatic radiation exposure of the population taken from the individual sources for the comparison and assessment of radiation exposure from various sources in future. Although the somatically significant dose constitutes the suitable variable complementary to GSD in ...
1984-06-01
ESR dosimetry of irradiated chicken legs and chicken eggs
Energy Technology Data Exchange (ETDEWEB)
Ionising radiation induces stable free radicals in chicken bones and in the shell of chicken eggs which can be detected, by the electrons spin resonance (ESR) technique, well beyond the shelf-life of the food and can be used for dosimetry. The method usually adopted to evaluate ``a posteriori`` the dose given during the ionising radiation treatment of food, is the dose additive method. To assess the dose, the ESR signal amplitude of the irradiated food (bone or egg shell in the present case) is measured and then the dose-effect relationship is obtained by re-irradiating the sample with some additive doses (usually of 1 kGy). The dose-effect curve is back-extrapolated and the initial given dose determined. At the Istituto Superiore di Sanita (ISS), Rome, Italy, a research programme was approved two years ago aimed to, (1) study new ...
1996-12-31
UK PubMed Central (United Kingdom)
PurposeTo investigate the influence of inhomogeneity corrections on stereotactic treatment plans for non-small cell lung cancer and determine the dose delivered to the PTV and OARs.Full Text Available
UK PubMed Central (United Kingdom)
IntroductionThe optimal dialysis dose for the treatment of acute kidney injury (AKI) is controversial. We sought to evaluate the relationship between renal replacement therapy (RRT)...Full Text Available
2009-01-01
A randomized-controlled trial of low-dose doxycycline for periodontitis in smokers
UK PubMed Central (United Kingdom)
Background/AimTobacco use reduces the effect of non-surgical periodontal therapy. Host-modulation with low-dose doxycycline (LDD) might favour repair and promote...Full Text Available
2007-04-01
Energy Technology Data Exchange (ETDEWEB)
Survival curves were constructed from dose-incidence curves for apoptosis in the crypts of mouse small intestine, using the number of apoptotic cells after high doses (N{sub M}) as maximum cell population size. The mean lethal doses (D{sub 0}) for the dose range 0-0.5 Gy were calculated for each time of day. A circadian rhythm in both D{sub 0} and N{sub M} values was detected, indicating that both the number and sensitivity of radiation-induced apoptosis were changing throughout the day. (author).
1990-07-01
Somatic radiation risk in X-ray diagnostics
Energy Technology Data Exchange (ETDEWEB)
The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.
1983-12-01
Somatic radiation risk in X-ray diagnostics
International Nuclear Information System (INIS)
The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).
1983-01-01
Serum Creatine Phosphokinase Activity after Intramuscular ...
... Title : Serum Creatine Phosphokinase Activity after Intramuscular Injection: The Effect of Dose, Concentration, and Volume. ...
1974-01-01
Savannah River Site dose control
Energy Technology Data Exchange (ETDEWEB)
Health physicists from the Brookhaven National Laboratory (BNL) visited the Savannah River Site (SRS) as one of 12 facilities operated by the Department of Energy (DOE) contractors with annual collective dose equivalents greater than 100 person-rem (100 person-cSv). Their charter was to review, evaluate and summarize as low as reasonably achievable (ALARA) techniques, methods and practices as implemented. This presentation gives an overview of the two selected ALARA practices implemented at the SRS: Administrative Exposure Limits and Goal Setting. These dose control methods are used to assure that individual and collective occupational doses are ALARA and within regulatory limits.
1992-01-01
Savannah River Site dose control
Energy Technology Data Exchange (ETDEWEB)
Health physicists from the Brookhaven National Laboratory (BNL) visited the Savannah River Site (SRS) as one of 12 facilities operated by the Department of Energy (DOE) contractors with annual collective dose equivalents greater than 100 person-rem (100 person-cSv). Their charter was to review, evaluate and summarize as low as reasonably achievable (ALARA) techniques, methods and practices as implemented. This presentation gives an overview of the two selected ALARA practices implemented at the SRS: Administrative Exposure Limits and Goal Setting. These dose control methods are used to assure that individual and collective occupational doses are ALARA and within regulatory limits.
1992-06-01
Review of electron beam therapy physics
Energy Technology Data Exchange (ETDEWEB)
For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)
2006-07-07
Projection techniques in diagnostic radiography discussed with regard to required dose
International Nuclear Information System (INIS)
The paper presents information in the form of data, tables and diagrams compiled to a broad but very up-to-date survey of required radiation for the various most frequently performed X-ray examinations of patients. The required dose is discussed from the point of view of radiation protection, defining the inevitably administered dose to the skin, the frequency of examinations, and the diagnostic image quality as the main three factors to be observed, as these determine the radiation dose to the patient and to the personnel. The somatic risks of radiography examinations are a point of main interest. (DG).
1990-09-01
Patient doses in the Netherlands. [X-ray diagnosis and radiotherapy
Energy Technology Data Exchange (ETDEWEB)
Contributions to the population dose due to medical applications of ionising radiation are presented. It appears that contributions due to radiotherapy and X ray diagnosis are of comparable magnitude. To account for the age dependency of the radiation risks, contributions in terms of somatically significant dose equivalent are calculated as 0.3 mSv per caput per annum for X ray diagnosis and as 0.2 mSv per caput per annum for radiotherapy, the latter referring to only doses to organs outside the target volume. (author).
1991-01-01
Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography
Energy Technology Data Exchange (ETDEWEB)
Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).
1991-08-01
Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography
International Nuclear Information System (INIS)
Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).
1991-01-01
New concepts in risk assessment for patients with radiological treatment
International Nuclear Information System (INIS)
In radiation risk assessment it must be differentiated between somatic and genetic effect on the one hand as well as between stochastic and non-stochastic effect on the other. According to definitions of the ICRP report 26 the limit for the dose equivalent of all tissues prevents non-stochastic radiation effects. With stochastic radiation effects probably exist no threshold doses; therefore the ALARA principle must be applied concerning radiation protection. The individual risk by stochastic radiation effects in its linear, linear-quadratic and quadratic extrapolations, respectively, is discussed in detail. The effective stochastic dose equivalent (H/sub eff/) as well as collective dose and collective damage are outlined.
1986-01-01
Measuring relative probability of Am-242 #beta#-decay
International Nuclear Information System (INIS)
... americium 241 americium 242 beta decay chain reactions integral doses mass
Electron Beam and Gamma Radiolysis of Solid-State Metoclopramide
British Library Electronic Table of Contents (United Kingdom)
Purpose Study the radiolysis of solid-state metoclopramide hydrochloride at various absorbed doses. Elucidate the structure of the degradation products to gain information on the radiolysis mechanisms. Methods Solid-state metoclopramide samples were irradiated at several doses with gamma rays and high-energy electrons to evaluate the influence of the dose rate. High-performance liquid chromatography with a diode array detector was used to measure the chemical potency as a function of the absorbed dose and to quantify the degradation products. The characterization of degradation products was performed by liquid chromatography/atmospheric pressure chemical ionization/tandem mass spectrometry. Results The degradation of solid-state metoclopramide after irradiation was negligible. No qualitati...
2006-01-01
Effect of low dose of radioactive iodine on mammalian brain development
International Nuclear Information System (INIS)
Russian 1997 p. 266-267 Russian Federation Ushakova, GA
However, market based pricing doses not apply where the pricing .... the reimbursable work, market based pricing does not apply. 040202. ...
International Nuclear Information System (INIS)
During one year more than 40,000 items of information on radiation exposure of personnel involved in the handling of radiation sources and more than 5,000,000 items on irradiation of other people are collected in the authors' laboratory. Considerable progress in assessment of mean annual gonad dose of genetically sifnificant dose was attained by means of an algorithm for a personal computer. This simple and inexpensive system has led to a higher accuracy in the application of protective measures. (author).
1985-10-22
A marine compartment model for collective dose assessment of liquid radioactive effluents
International Nuclear Information System (INIS)
A compartment model is described which is currently used by the Ministry of Agriculture, Fisheries and Food to calculate collective radiation exposure due to liquid radioactive wastes discharged to sea from UK nuclear sites. Collective dose is a useful indicator of the radiological impact of a disposal practice and is one of the quantities needed to show compliance with the ICRP system of dose limitation. The model has been used for the purposes of the Sizewell Inquiry to predict the collective radiation exposure from reactor operation at Sizewell and, on the basis of current Sellafield experience, correlations between dose and discharge for disposals of fuel reprocessing wastes. (author).
1982-01-01
In a recent survey of the stellar populations of LINERS and LINER/HII Transition Objects (TOs) we identified a numerous class of nuclei which stand out because of their conspicuous 10^8-9 yr populations. These objects were called ``Young-TOs'', since they all have TO-like emission line ratios. In this paper we investigate the radial variations of spectral properties in Low Luminosity AGN. Our analysis is based on high S/N, 3500-5500 A, long-slit spectra for 47 galaxies. The data probe distances of typically up to 850 pc from the nucleus with a resolution of ~ 100 pc and S/N ~ 30. Stellar population gradients are mapped by the radial profiles of absorption line equivalent widths and colours along the slit. These variations are further analyzed by means of a decomposition of each spectrum in terms of template galaxies representative of very young (<= 10^7 yr), intermediate age (10^8-9 yr) and old (10^10 yr) populations. Our main findings are: ...
2004-01-01
Structure and kinematics of edge-on galaxy discs -- IV. The kinematics of the stellar discs
The stellar disc kinematics in a sample of fifteen intermediate- to late-type edge-on spiral galaxies are studied using a dynamical modeling technique. The sample covers a substantial range in maximum rotation velocity and deprojected face-on surface brightness and contains seven spirals with either a boxy- or peanut-shaped bulge. Dynamical models of the stellar discs are constructed using the disc structure from $I$-band surface photometry and rotation curves observed in the gas. The differences in the line-of-sight stellar kinematics between the models and absorption line spectroscopy are minimized using a least-squares approach. The modeling constrains the disc surface density and stellar radial velocity dispersion at a fiducial radius through the free parameter $\\sqrt{M/L}$ $(\\sigma_{\\rm z}/\\sigma_{\\rm R})^{-1}$, where $\\sigma_{\\rm z}/\\sigma_{\\rm R}$ is the ratio of vertical and radial velocity dispersion and $M/L$ the disc ...
2005-01-01
Development of magnetic drive packless valves for commercial purpose
Energy Technology Data Exchange (ETDEWEB)
A study on development of magnetic drive packless valves for commercial purpose showed the results as follows; 1. Study on the radial rays effecting to the permanent magnets -Measurement of the strength of Nd-magnets according to irradiation of radial rays. 2. Effects of temperature on the magnetic driving device -Temperature dependency of the Nd-casting magnets. -Effects of temperature on the heat releasing fins of high-temperature valve. 3. Optimization of torque -Arranging method of permanent magnets -Measuring method and results of torque. 4. Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Calculation and design for the flat circular plates under pressure of the magnetic power transmitting device -Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Comparison of the characteristics between magnetic drive valve and ...
1995-09-01
A numerical investigation of the aerodynamics of a furnace with a movable block burner
Scientific Electronic Library Online (English)
Abstract in english In this work the air flow in a furnace was computationally investigated. The furnace, for which experimental test data are available, is composed of a movable block burner connected to a cylindrical combustion chamber by a conical quarl. The apertures between the movable and the fixed blocks of the burner determine the ratio of the tangential to the radial air streams supplied to the furnace. Three different positions of the movable blocks were studied at this time. A thr (more) ee-dimensional investigation was performed by means of the finite volume method. The numerical grid was developed by the multiblock technique. The turbulence phenomenon was addressed by the RNG k-epsilon model. Profiles of the axial, tangential and radial velocities in the combustion chamber were outlined. The map of the predicted axial velocity in the combustion chamber was compared with a map of the experimental axial velocity. The internal space ...
2007-06-01
Website Policies and Important Links Comments