Stenting for stenosis of the proximal vertebral artery (VA) is commonly performed via a femoral approach. However, iliofemoral occlusive disease such as arteriosclerosis obliterans sometimes prevents safe transfemoral access. In certain situations where both femoral access and ipsilateral brachial access are difficult because of a concomitant vascular diseases or particular anatomic setting, a contralateral brachial approach using the brachiobrachial pull-through technique may allow efficient and accurate stenting. A case of VA origin symptomatic stenosis successfully treated with stenting using the new pull-through technique from the contralateral brachial artery to the brachial artery on the affected side is described. (orig.)
BackgroundWave reflection during the systole increases left ventricular (LV) pressure, tension-time index (TTI) and myocardial oxygen requirement. The purpose of this study was to extract that component of extra myocardial oxygen requirement that is due to early systolic wave reflection, define it as wasted effort (?Ew), and examine its relationship to LV hypertrophy (LVH).MethodsRadialartery pressure waveforms were recorded using applanation tonometry and central aortic waveforms generated in 98 patients with untreated hypertension. Aortic augmentation index (AIa), wave reflection amplitude (i.e., aortic augmented pressure (AG)) and systolic duration (ED?Tr), ejection duration (ED) and round-trip travel time of the pressure wave (Tr) were calculated from the aortic waveform, a...
The endovascular treatment of atherosclerotic intracranial arterial stenoses has previously been based on balloon dilatation or the deployment of a balloon expandable stent. Both methods have advantages (balloon: flexibility; balloon expandable stent: high radial force) and drawbacks (balloon: risk of elastic recoil and dissection; balloon expandable stent: limited flexibility, risk of injury to the vessel due to excessive straightening, overexpansion at ends of stent). A new combination of balloon dilatation, followed by the deployment of a self-expanding microstent has been applied in 15 patients with atherosclerotic arterial stenoses, symptomatic despite medical treatment. An anatomically and clinically adequate result was achieved in all patients. The initial degree of stenosis was 72% (mean). Balloon dilatation resulted in an average residual stenosis of 54% (mean), reduced further to a mean of 38% after stent ...
A new test methodology is described which allows access to loading rates that lie between split Hopkinson bar and shock-loading techniques. Gas gun experiments combined with velocity interferometry techniques have been used to experimentally determine the intermediate strain-rate loading behavior of Coors AD995 alumina and Cercom silicon-carbide rods. Graded-density materials have been used as impactors; thereby eliminating the tension states generated by the radial stress components during the loading phase. Results of these experiments demonstrate that the time-dependent stress pulse generated during impact allows an efficient transition from the initial uniaxial strain loading to a uniaxial stress state as the stress pulse propagates through the rod. This allows access to intermediate loading rates over 5 x 10{sup 3}/s to a few times 10{sup 4}/s.
The purpose of this study was to evaluate the feasibility, efficacy and safety of percutaneous thromboaspiration with a Desilets-Hoffman Sheath compared with the previously established percutaneous mechanical thrombectomy technique in cases of occluded dialysis graft. One hundred and sixty eight patients (103 women, 65 men; mean age, 54.7 years; mean graft age, 20.9 months) with 225 episodes of dialysis graft thrombosis underwent percutaneous thromboaspiration with a 7F Desilets-Hoffman sheath using the crossing catheter or single puncture technique. The technical success rate, procedure time, and complication and patency rates were analyzed. Technical success was achieved in 200 of the 225 procedures (88.9%). The average duration of the intervention was 74.3 {+-} 35 minutes. The primary patency rate was 63.1% at 3 months, 44.2% at 6 months and 26.3% at 1 year. Major complications occurred in 4% of the cases (4 venous ruptures; 4 arterial embolisms; 1 ...
To evaluate the usefulness of three-dimensional (3D) rotational angiography, cervical carotid or cerebral angiography was done without catheterizing the branches of the thoracic aorta. A 5-Fr pig-tail type catheter was passed into the ascending aorta via the radialartery or the femoral artery. Optimal carotid angiogram views were obtained using approximately 45 ml of contrast medium at a flow rate of 15 ml/sec. Optimal cerebral angiogram views were obtained using approximately 70 ml of contrast medium at a flow rate of 20 ml/sec. The contrast medium concentration was 300 to 350 mgI/ml. A satisfactory view could be obtained in 5 of 8 (63%) cases on cervical carotid 3D angiography and in 8 of 14 (57%) cases on cerebral 3D angiography. In all cases, no complications were noted. This method offers the advantages of requiring a relatively short procedure time and a decrease in radiation exposure. Further studies are needed to ...
The aim of the paper is to review the role of interventional radiology in the management of hemodialysis vascular access and complications in renal transplantation. The evaluation of patients with hemodialysis vascular access is complex. It includes the radiology/ultrasound (US) evaluation of the peripheral veins of the upper extremities with venous mapping and the evaluation of the central vein prior to the access placement and radiological detection and treatment of the stenosis and thrombosis in misfunctional dialysis fistulas. Preoperative screening enables the identification of a suitable vessel to create a hemodynamically-sound dialysis fistula. Clinical and radiological detection of the hemodynamically significant stenosis or occlusion demands fistulography and endovascular treatment. Endovascular prophylactic dilatation of stenosis greater than 50% with associated clinical abnormalities such as flow-rate reduction ...
Purpose: The aim of this study was to test the feasibility of iliac artery stent placement under MR guidance with real-time MR radial scanning in an animal model. Materials and methods: The experiments were performed on three pigs in a 1.5 T scanner. Radial scanning with a gradient echo technique (T{sub R} 8.4 ms, T{sub E} 3.6 ms, flip angle 10 ) was used. A dedicated backprojector performed the reconstruction of the raw data in real-time. The resulting MR-images were displayed on LCD screens beside the magnet. The sliding window reconstruction technique allowed image acquistion at a frame rate of 16 images per second. MR-compatible self-expanding stents with a diameter of 8 mm and a length of 3 cm were placed into the left iliac artery. Their positions were verified by digital subtraction angiography (DSA) and compared to MRI. Results: All stents were successfully placed. Stent positions as monitored ...
We previously demonstrated the ability to create engineered arteries by carefully controlling the mechanical environment of intact arteries perfused ex vivo, yielding engineered arteries...Full Text Available
To determine the effectiveness and patency of percutaneous intervention in insufficient native arteriovenous hemodialysis fistulae (AVFs). Between March 1997 and September 2001, 67 cases of insufficient native AVFs resulted from central vein lesion, PTA was performed in 48 cases, and thrombolytic therapy with or without PTA in 11. In eight of the cases, in which central vein stenosis had led to the insufficency, percutaneous transluminal angioplasty (PTA) was performed, and in three of the eight, a stent was inserted. Angiography findings and complications, as well as success and patency rates in the non-thrombosis and thrombosis group, were evaluated; the central vein lesion group was analysed separately. Among 84 lesions observed at angiography, three were 54 cases of stenosis, 17 of occlusion, and 13 of combined thrombosis. The lesions were located in a proximal vein (n=51), distal vein (n=14), artery (n=6), and at the site of anastomosis (n=13). In the central ...
The mechanical properties of metal stents are important parameters in the consideration of stent design, matched to resist arterial recoil and vascular spasm. The purpose of this study was to develop a system for a standardized quantitative evaluation of the mechanical characteristics of various coronary stents. Several types of stents were compressed by external hydrostatic pressure. The stent diameter was assessed by placing a pair of small ultrasonic sono-crystals on the stent. From pressure-strain diagrams the ultimate strength and radial stiffness for each stent were determined. For all stents, except the MICRO-II and the Wiktor stent, the diameter decreased homogeneously until an ultimate compressive strength was exceeded, causing an abrupt collapse. Expanded to 3 mm, the mechanical behavior of the beStent, the Crown and the Palmaz-Schatz stent (PS153-series) were comparable. The spiral articulated Palmaz-Schatz stent showed twice the ...
The subtemporal approach with division of the posterior communicating artery (PcomA) is described for treating aneurysms of the basilar tip. When the ipsilateral posterior cerebral artery (PCA) interferes...Full Text Available
Ninety-four patients with peripheral arterial injuries were subjected to acute repair, negative exploration, or late repair of the complications of the arterial injury (false aneurysm, A-V fistula,...Full Text Available
The use of cathode ray irradiated arterial allografts on the reconstruction of small peripheral arteries is described. The fate of irradiated arterial allografts implanted subcutaneously in rats was compared histologically with that of allografts which were fresh, frozen or stored in 70% alcohol. Follow-up studies were made of 10 dogs in which irradiated arterial allografts had been implanted in the femoral artery to be evaluated; long term patency by arteriography, gross and histologic changes of the implanted allografts, and the luminal surface of the implanted allografts by scanning electron microscopic studies. For the purpose of antigenic studies, extracts of canine arteries which had been irradiated, frozen or stored in 70% alcohol, were prepared and tested by the following immunological methods: precipitation, Ouchterlony gel diffusion, and passive ...
We present a method to make phantoms of coronary arteries for intravascular optical coherence tomography (IV-OCT). The phantoms provide a calibrated OCT response similar to the layered structure of...Full Text Available
The antiphospholipid syndrome (APS) is a multi-systemic disease being characterized by the presence of antiphospholipid antibodies that involves both arterial and venous systems resulting in arterial...Full Text Available
Purpose. To evaluate the efficacy of percutaneous transluminal angioplasty (PTA) in the management of arterial stenosis located close to the allograft anastomosis (close-TRAS)....Full Text Available
The DataAccessBean is similar to the Data Access Object (DAO) interface in that the DataAccessBean interface is meant to encapsulate the implementation details of the DynamicJavaBean that accesses persistent storage devices such as RDBMS, flat text file databases, etc.
The transposition of the great arteries afters to an abnormal connection and relation of the great arteries in which the aorta arises from the morphologic right ventricle and the pulmonary artery from the morphologic left ventricle, while the malposition of the great arteries indicates an abnormal relationship between the great arteries in which the great arteries are not transposed across the ventricular septum but they are malposed, as is seen in double outlet right ventricle, double outlet left ventricle and single ventricles. Transpositions and malpositions of the great arteries are understood as a spectrum of malformation caused by abnormal conal development and can be included in the common category of 'conotruncal malpositions'. Authors analized 32 cases of transpositions and malpositions of the great arteries in ...
BackgroundTraumatic paediatric arterial injuries are a great challenge due to low incidence and specific characteristics of paediatric anatomy and physiology. The aim of the present...Full Text Available
Successful management of a patient with tracheo-innominate artery erosion requires the rapid institution of specific resuscitative and operative measures. Ten patients seen at the Charity Hospital of...Full Text Available
Alterations in mass transport patterns of low-density lipoproteins (LDL) and oxygen are known to cause atherosclerosis in larger arteries. We hypothesise that the species transport processes in coronary...Full Text Available
Spontaneous coronary artery dissection (SCAD) is an extremely uncommon cause of myocardial infarction, occurring predominantly in women during or after pregnancy. The exact aetiology...Full Text Available
Background and objectives: Management of incidental renal artery and kidney abnormalities in patients undergoing computed tomography scans is a clinical challenge because their frequency in healthy...Full Text Available
In recent years, percutaneous coronary intervention (PCI) has become a well-established technique for the treatment of coronary artery disease. PCI improves symptoms in patients with coronary artery...Full Text Available
Patent arterial duct (PAD) is a congenital heart abnormality defined as persistent patency in term infants older than three months. Isolated PAD is found in around 1 in 2000 full term infants. A higher...Full Text Available
Background and purpose:The chicken anterior mesenteric artery contains an outer longitudinal smooth muscle layer, whose neural regulation remains to be elucidated. ATP evokes a depolarization...Full Text Available
In an earlier report, we used differential cloning to identify genes that might be critical in controlling arterial neointima formation (Giachelli, C., N. Bae, D. Lombardi, M. Majesky, and S. Schwartz....Full Text Available
Sudden unexpected postoperative hemodynamic collapse with a high mortality develops in 1–3% of patients undergoing coronary artery bypass surgery (CABG). The contribution of surgical graft complications...Full Text Available
ObjectiveThe aim of this study was to evaluate the utility of volume-rendered helical computerized tomography (CT) angiography focusing tracheostomy tube and innominate artery for...Full Text Available
Despite the recent success of genome-wide association studies (GWASs) in identifying loci consistently associated with coronary artery disease (CAD), a large proportion of the genetic components of...Full Text Available
Pseudoaneurysms related to the superior mesenteric artery (SMA) are a recognised complication of trauma to the vessel, and successful treatment with stenting has been previously described. We report...Full Text Available
1. This study analyzes the mechanisms involved in the responses to ouabain in cat cerebral and femoral arteries and characterizes the electrogenic Na+ pump present in these vessels. The latter was accomplished...Full Text Available
Gradual occlusion (O) of the swine left circumflex coronary artery (LCX) with an ameroid occluder results in complete O within 3 weeks, collateral vessel development, and compensatory hypertrophy....Full Text Available
ObjectiveTo determine if an aggressive approach to coronary revascularisation with oversized balloons is counterproductive, we studied the effect of increasing balloon‐to‐artery...Full Text Available
Coronary artery disease (CAD) is the single most common cause of death in the developed world, responsible for about 1 in every 5 deaths. The morbidity, mortality, and socioeconomic importance...Full Text Available
Approximately 20% to 30% of patients who undergo coronary arteriography for the evaluation of chest pain are found to have normal coronary arteries. These patients have a survival rate comparable to...Full Text Available
BackgroundVisceral artery aneurysms (VAA), although uncommon, are increasingly being detected. We describe a case of spontaneous retroperitoneal hemorrhage from a ruptured IMA aneurysm...Full Text Available
OBJECTIVE: To assess the association between erectile dysfunction (ED) and the long-term risk of coronary artery disease (CAD) and the role of age as a modifier of this association.PARTICIPANTS...Full Text Available
Pulmonary embolism complicated by transcatheter arterial chemoembolization (TACE) in known to be due to the use of large amount of lipiodol as an embolic agent. To our knowledge, massive tumoral pulmonary embolism following TACE and confirmed by surgery has not been described in the literature. In this report, we detail the cas of a 49-year-old man in whom cyanosis and hypotension developed abruptly on the day of TACE.. Chest CT revealed diffuse low-attenuated lesions in both pulmonary arteries. Histopathological specimens after emergent pulmonary arterial embolectomy confirmed the presence of massive tumor emboli of hepatocellular carcinoma.
27 cases including 7 outpatients, underwent intraarterial DSA using 4-F nylon catheter, by transbrachial arterial approach. Much of DSAs were performed in Fuji Computed Radiography (FCR), which has high spatial resolution. In all cases, image quality satisfied clinical demands. No major complication occured in this series. Transbrachial arterial digital subtraction angiography is excellent and safe method for screening of vascular disease. (author).
Background: the fact that therapeutic irradiation can induce significant stenosis in the arteries of the head, neck, and chest, as welt as in the aorta and the iliac arteries, is familiar in daily practice and well documented in the literature. By contrast, radiation-induced renal artery stenosis seems to be a less widely known complication. Patients and methods: the sudden onset of medically refractory arterial hypertension and coma in a 27-year-old man is reported, who had been treated at age 20 with chemotherapy and radiotherapy for Ewing's sarcoma in the lumbar region. This treatment had been performed at the hospital of Sion, Switzerland in 2001. Also, the relevant literature from 1965 to 2007 is reviewed to underscore various aspects of this problem and to demonstrate the clinical relevance of renal artery stenosis as a potential long-term sequela of radiotherapy. Conclusion: ...
Angiography plays a vital role in the investigation of the patient suffering from multiple trauma. The commonest injuries have been rupture of the thoracic aorta, renal lacerations, arterial bleeding associated with fractures and soft-tissue injuries to the pelvis, and occlusions of the arteries supplying the limbs. Transcatheter arterial embolization may be the definitive therapeutic procedure in pelvic bleeding.
This paper discusses the evolution of the horizontal subsea tree and its utilization in increasingly demanding applications. Initially, the Horizontal Tree was seen as a solution for wells requiring high well maintenance, such as those using electrical downhole pumps. Today, the horizontal tree is being applied to natural drive wells because of attractive whole life economics. This raises concern in a number of areas. Tubing hanger seals are permanently exposed to well fluids, and must provide high integrity sealing. This required the development of a new type of radially energized, all metal sealing system, specifically for horizontal tree applications, suitable for oil or gas service at working pressures to 15,000 psi. In addition, horizontal tree pressure integrity depends on the master valve stem, gate and bonnet seals. The need for high seal integrity also dictates that the first master valves should be integral to the main body of the tree, to maximize ...
A single radial hemolysis test was developed for quantitation of specific antibody to non-hemagglutinating viruses. With the human coronaviruses as models, this test utilizes the binding properties...Full Text Available
Background and purposeRadial head fractures are common, and may be associated with other injuries of clinical importance. We present the results of a standard additional MRI scan...Full Text Available
The influence of geometry and operating conditions of the centrifugal compressor stage on the radial gas force is determined on the basis of the theoretical method and calculation program using experimental boundary conditions.
An earlier representation of the radial distribution of dose about the path of a heavy ion in liquid water is modified and extended to include silicon, lithium fluoride, and sodium iodide. 6 refs., 5 figs., 1 tab.
A radial-flow type internally oil-cooled oil-filled cable has been developed. This system is characterized in that the oil flows radially through the paper insulation. The thermal resistance of the insulation is equivalently decreased by the radial-flow. The decreased thermal resistance as well as the cooling effect of the oil flow in the central oil duct and the outer oil duct under an aluminum sheath increase the current capacity. A calculation method of cooling characteristics is introduced. The stability of the cable and accessories was confirmed through initial electrical tests and a long-term field test.
The efficient use of the fuel is one of the objectives in the assemblies design of type BWR. The present tendency in the assemblies design of type BWR is through a radial distribution of enrichments. The present work has like object showing the because of this decision, for what a comparison of the neutronic performance of two fuel cells with the same enrichment average but one of them with radial distribution of enrichment and the other with a single enrichment equal to the average. The cells were analyzed with the CASMO-4 code and the obtained results of the behavior of the neutron flow and the power sustain the because of the radial distribution of enrichments. (Author)
The aim of this study was to evaluate the feasibility of splitting each head of the gastrocnemius muscle into two segments. This prospective study was conducted on 35 fresh cadavers with injection of radio-opaque contrast material in the popliteal artery. Seventy medial gastrocnemius and 70 lateral gastrocnemius muscle specimens were obtained. Gastrocnemius intramuscular arterial anatomy was analysed by using the digital X-ray technique. The most common vascular pattern found in this study was both bellies supplied by individual sural arteries, which shows distal bifurcation. The medial sural artery always showed bifurcation in the medial gastrocnemius muscle in both lower limbs, whereas this bifurcation of the lateral sural artery was present in only 87% cases and 13% of cases showed a si...
Transcatheter coil embolization for coronary artery to left ventricular fistula was successfully performed in a neonate. At 30 weeks' gestation, fetal echocardiography showed a hypoplastic right ventricle with intact ventricular septum, absent pulmonary valve, tricuspid atresia, and marked distension of the right coronary artery. After birth, the neonate had congestive heart failure and the electrocardiogram showed myocardial ischemic changes in the left ventricular area. Aortography showed a dilated right coronary artery arising from the ascending aorta and draining into the left ventricle. Transcatheter coil embolization was carried out on the 9th day after birth. Since the procedure, no myocardial ischemic changes have been detected. Transcatheter coil embolization is a useful therapy for coronary artery fistula associated with myocardial ischemia. PMID:15564713
The aim of this article is to report our experience in the diagnosis of two cases of iliac artery endofibrosis or arteriopathy, a rare entity occurring in high-performance athletes, presenting with intermittent claudication (right-sided in both) after maximal exercise. External iliac artery endofibrosis or arteriopathy is a likely diagnosis in competitive athletes free of cardiovascular risk factors who present with leg claudication. Arteriography and a papaverine-assisted mean pressure gradient across the iliac arteries of more than 10 mmHg is a useful diagnostic approach. Moreover, balloon angioplasty of the iliac artery in that patient, in whom a pressure gradient was detected, resulted in symptomatic relief for 2 months followed by mild symptom recurrence. Thus, although balloon angioplasty is feasible and safe, it might not be adequate to treat this entity and, thus, its value remains undefined.
Background: Superficial inferior epigastric artery (SIEA) flap has a great advantage over other flaps of the area, that is, readily non-existent donor-site problems. The main reason why the SIEA flap has never been extensively used in breast reconstruction is the small diameter and variable anatomy of its donor artery. This study presents a possibility of enlarging the SIEA diameter using the delay-phenomenon mechanism. Methods: A prospective clinical study of 26 patients was undertaken. Prior to surgery, ultrasound examinations were performed, measuring the diameter of SIEA and the velocity of blood flow in SIEA. The ipsilateral deep inferior epigastric artery (DIEA) was then ligated in all patients who had a measurable SIEA preoperatively. Two weeks later, measurements were repeated. The...
All patients with von Willebrand?s disease (vWD) who showed an arterial or venous thrombosis and were reported in the literature have been evaluated. 11 patients had arterial thrombosis while 19 had venous thrombosis for a total of 30 cases. 9 out the 11 cases with arterial thrombosis had myocardial infarction. Two had cerebral thrombosis. Associated risk factors for arterial thrombosis were available only for three patients who showed, respectively, smoking and dyslipidemia (2 cases) and smoking and intravenous desmopressin infusion (1 case). The majority of patients with venous thrombosis showed DVT with or without PE. Four patients presented with apparently isolated PE. In two instances thrombosis occurred in unusual sites (central retinal vein and portal vein, respectively). Several as...
We have performed precision measurements in a magneto-optical trap of the 7P1/2 hyperfine structure of the isotopes 209-210Fr. The ratio of these hyperfine constants to the previously measured 7S1/2 ground state values reveals a significant hyperfine anomaly. This anomaly results from the different radial dependence of the electron density in the two atomic levels. The measurements are sensitive to changes in the radial distribution of the neutron magnetism.
The radial distribution function (RDF) derived from wide angle X-ray diffraction patterns gives additional information about the spatial distribution of atoms. Their radial distances and relative average coordination numbers can be calculated using appropriate mathematical procedures. 7 refs.
We investigated a method of analyzing the hemodynamics of the lung mass by contrast enhanced dynamic computed tomography (dynamic CT) to determine the difference in vascular supply between the pulmonary artery and bronchial artery using an experimental model. Our experimental model consisted of two injectors connected to two tubes, representing the pulmonary artery and bronchial artery, which were further connected to a chamber representing the lung mass. Following infusion of contrast medium into each tube with some delay time, dynamic CT scans were performed to obtain time density curves of the two tubes and the chamber. Using the time-density curve of contrast passage, flow rates from the two tubes into the chamber were calculated by the curve fitting method. Calculated values correlated well with the adopted flow rates of fluid from the injectors (r=0.893) in the experiment. The results indicate our ...
We investigated a method of analyzing the hemodynamics of the lung mass by contrast enhanced dynamic computed tomography (dynamic CT) to determine the difference in vascular supply between the pulmonary artery and bronchial artery using an experimental model. Our experimental model consisted of two injectors connected to two tubes, representing the pulmonary artery and bronchial artery, which were further connected to a chamber representing the lung mass. Following infusion of contrast medium into each tube with some delay time, dynamic CT scans were performed to obtain time density curves of the two tubes and the chamber. Using the time-density curve of contrast passage, flow rates from the two tubes into the chamber were calculated by the curve fitting method. Calculated values correlated well with the adopted flow rates of fluid from the injectors (r=0.893) in the experiment. The results indicate our ...
We report a patient who developed occlusion of the intracranial major arteries induced by radiation therapy for craniopharyngioma. The patient, a 9-year-old boy, presented with deterioration of vision, nausea and vomiting. He underwent a right ventriculo-peritoneal shunt operation, and the tumor was partially removed. Postoperatively, he received focal radiation therapy with total of 60 Gy. Preoperative cerebral angiography, cerebral vessels had no sigh of occlusive lesion or stenosis. One year after irradiation, he started to have repeated cerebral ischemic attacks. But no regrowth of the tumor was detected on CT scans. Two years and 8 months after irradiation, he suddenly had right hemiparesis. Cerebral angiography revealed severe stenosis of the right anterior cerebral artery (precommunicating segment), middle cerebral artery (horizontal portion) and terminal portion of the right carotid artery. Left ...
We report a patient who developed occlusion of the intracranial major arteries induced by radiation therapy for craniopharyngioma. The patient, a 9-year-old boy, presented with deterioration of vision, nausea and vomiting. He underwent a right ventriculo-peritoneal shunt operation, and the tumor was partially removed. Postoperatively, he received focal radiation therapy with total of 60 Gy. Preoperative cerebral angiography, cerebral vessels had no sigh of occlusive lesion or stenosis. One year after irradiation, he started to have repeated cerebral ischemic attacks. But no regrowth of the tumor was detected on CT scans. Two years and 8 months after irradiation, he suddenly had right hemiparesis. Cerebral angiography revealed severe stenosis of the right anterior cerebral artery (precommunicating segment), middle cerebral artery (horizontal portion) and terminal portion of the right carotid artery. Left ...
This document is divided in two parts. The first part deals with the radial velocities (RV) distributions for B-type stars and nebulosities observed with the VLT-GIRAFFE in the Large and Small Magellanic Clouds towards the open clusters NGC2004 and NGC330. Thanks to the resolution of GIRAFFE spectra, we found that the RV distribution for the nebulosities in the LMC is bi-modal. This bi-modality can be interpreted, in term of dynamics, by the expansion of the LMC4 superbubble. The second part deals with the GAIA space mission and the determination of the radial velocities by using Radial Velocity Spectrometer (RVS) spectra. The methods to determine the radial velocities are presented as well as preliminary results on simulated RVS spectra.
The Monte-Carlo method and experimental methods were used to determine the neutron fluxes in the irradiation channels of the Ghana Research Reactor -1. The MCNP5 code was used for this purpose to simulate the radial and axial distribution of the neutron fluxes within all the ten irradiation channels. The results obtained were compared with the experimental results. After the MCNP simulation and experimental procedure, it was observed that axially, the fluxes rise to a peak before falling and then finally leveling out. Axially and radially, it was also observed that the fluxes in the centre of the channels were lower than on the sides. Radially, the fluxes dip in the centre while it increases steadily towards the sides of the channels. The results have shown that there are flux variations within the irradiation channels both axially and radially. (au)
Purpose: This preliminary report describes the development and implementation of a project to improve access to literature in Latin American social medicine (LASM).Methods:...Full Text Available
The adverse effects and diagnostic accuracy of thallium-201 myocardial SPECT after intravenous infusion of adenosine triphosphate (ATP) were studied and compared with SPECT examinations with other type of loading. The subjects of the study were 147 patients with or without coronary artery disease, who underwent some type of loading SPECT and coronary arteriography (CAG) within 30 days. Myocardial ischemia was evaluated qualitatively in SPECT and was compared with CAG for the diagnostic accuracy of coronary artery disease. The degree of myocardial uptake defect was also calculated semiquantitatively using visual scoring method and compared with coronary artery severity score. The adverse effects occurred in 46.7% of ATP loading SPECT which was more frequent that DIP loading SPECT, but all of them were transient and mild. As for the diagnostic ability the ATP loading SPECT was as effective as other type of loading in ...
Adenosine triphosphate (ATP) is an alternative to dipyridamole or adenosine in thallium-201 myocardial scintigraphy. However, the optimal dose of ATP has not been determined. A Doppler guide wire study showed the coronary flow velocity at a dose of 0.15 mg/kg of ATP was equal or higher than that at 0.14 mg/kg of adenosine or 0.56 mg/kg of dipyridamole. ATP was given intravenously to 67 patients with coronary artery disease at 0.15 mg/kg/min for 6 min. Thallium-201 was injected at 3 min, followed by immediate and delayed (3 hrs) tomographic imaging. There was no serious side effect during examination, although chest pain (26%), dyspnea (17%), and flushing (33%) were common. The sensitivity and specificity to detect coronary artery disease were 98 and 100%, respectively. The sensitivity to detect left anterior descending artery, left circumflex artery, and right coronary artery ...
This report describes a technique of inserting an implantable venous access port (portacath) through a thrombosed and occluded vein employing a pre-existing peripherally inserted central catheter (PICC) as the route of access. The PICC was used as a conduit for venous access in a way that has not been described previously in the literature. This procedure was performed in a young patient with cystic fibrosis in an effort to prevent the use of his virgin contralateral veins, which might be used in the future.
Steam generators for nuclear plants require access to the primary and secondary side for various inspection, cleaning and repair procedures and upon achieving access various inspection and cleaning tasks must be carried out. Steam generators currently at manufacture are therefore provided with; primary side access via the primary manways, steam drum access via the steam drum manway, U-bend region access via the secondary manway and drum-internals access passages, tubesheet secondary side access via tubesheet level inspection ports and tube support plate access via tube support level access ports. Many CANDU steam generators were built with only primary and drum manways and either no tubesheet ports or ports which were located ineffectively. The steam generators at Wolsong 1 were built with secondary ...
Renal arteriovenous fistula or pseudoaneurysms developing after invasive procedures are either asymptomatic or show only transient symptoms. We describe here a case of symptomatic renal artery pseudoaneurysm that presented with gross hematuria and azotemia. The pseudoaneurysm of renal artery was diagnosed by ultrasonography and abdominal magnetic resonance imaging (MRI), and it was successfully treated by percutaneous transcatheter coil embolization. A high index of suspicion is essential for the early diagnosis and treatment of delayed gross hematuria in patients with history of percutaneous nephrostomy. PMID:17180737
The extent (density and diameter) of the native (preexisting) collateral circulation in healthy tissues and the capacity of collaterals to enlarge/remodel in obstructive arterial disease are important...Full Text Available
INTRODUCTIONMany surgeons will have encountered the scissors that would not cut, and the artery clip that comes off in a deep difficult location, but it would be reasonable to assume...Full Text Available
Serious complications due to coronary artery fistulae have been described. Most authors recommend early intervention at the time of diagnosis. We present a case of a fistula originating from a dilated left coronary artery and draining into the right atrium, which was diagnosed prenatally by color Doppler echocardiography. During pregnancy, the echocardiographic findings remained unchanged, and there were no signs of heart failure. After birth, the fistula was confirmed by angiography. Additionally, a persistent left superior vena cava draining into the coronary sinus and a very small ventricular septal defect were detected. The fistula was closed successfully by transcatheter coil embolization. At 17 months old the child was in good clinical condition. Prenatal diagnosis of coronary artery fistulae may be possible and may improve perinatal management and outcome. PMID:12047543
Nutcracker phenomenon refers to compression of the left renal vein, most commonly between the aorta and the superior mesenteric artery, with impaired blood outflow often accompanied by distention...Full Text Available
Background and PurposeHemodynamic insults at arterial bifurcations are hypothesized to play a key role in intracranial aneurysm formation. This study investigates...Full Text Available
Purpose. Formation of a tracheoinnominate artery fistula (TIF) and consecutive hemorrhage is a rare and life-threatening complication with high mortality. Warning symptoms can...Full Text Available
Chronic mesenteric arterial ischemia is an uncommon condition associated a high morbidity and mortality. It is most Commonly caused by atherosclerotic occlusive disease. Patients may suffer epigastric or periumbilical postprandial pain ten to thirty minutes after eating. A case of chronic mesenteric artery stenosis, the diagnosis was performance with colonoscopy and biopsy. We present a case report of a patient with chronic mesenteric ischemia. Mesenteric arteriography was performed and documented estenosis of the mesenteric superior artery. Then percutaneous arteriography with angioplasty and implant of stent was performed. The patients became completely asymptomatic and normal colon mucous is observed in control colonoscopy. The purpose of this report is to present the case endoscopy, clinic and radiological features and to describe the percutaneous angioplasty and implant of stent. We believe that angioplasty treatment ...
RationaleCollaterals are arteriole-to-arteriole anastomoses that connect adjacent arterial trees. They lessen ischemic tissue injury by serving as endogenous bypass...Full Text Available
Aim: This study was performed: 1) to assess the relationship between blood flow velocity in the internal carotid artery (CBFICA) and pial artery pulsation (cc-TQ) and 2) to evaluate flow-induced changes in pial artery compliance. Methods: Experiments were performed on 10 crossbred male rabbits. Heart rate (HR), blood pressure (BP), left ventricle ejection fraction (LVEF), CBFICA, the systolic-diastolic blood volume fraction in the brain circulation (CBFSDF) and cc-TQ were recorded after glucagon and acetazolamide administration. cc-TQ was measured with near-infrared transillumination back scattering sounding (NIR-T/BSS), LVEF and CBFSDF with gated scintigraphy and BP and CBFICA with electromagnetic pressure and flow transducers, respectively. Doses of drugs were chosen to exert a haemodyna...
ObjectiveAngiography remains a critical component for diagnostic imaging and therapeutic intervention in peripheral arterial disease (PAD). The goal of this study...Full Text Available
Opinion statementCritical limb ischemia (CLI), defined as chronic ischemic rest pain, ulcers, or gangrene attributable to objectively proven arterial occlusive disease, is the most advanced...Full Text Available
The most frequent ultimate cause of death is myocardial arrest. In many cases this is due to myocardial hypoxia, generally arising from failure of the coronary macro- and microcirculation to deliver...Full Text Available
...Section 508 and Electronic Information Technology Accessibility at EPA | US EPA Jump to main content. Section 508 and Electronic Information Technology ...Us Search: All EPA Advanced search You are here: EPA Home Section 508 and Electronic Information Technology Accessibility at EPA Welcome to the United ... Section 508 of the Rehabilitation Act mandates that Federal departments and agencies make electronic and information technology (EIT) accessible to individuals ... Achieving compliance with Section 508 is an ongoing process. If you have any problems or questions about accessing information on a particular ...
To aid in the study of lower hybrid current drive as a means of current profile control, the radial profile and velocity distribution of the fast current-carrying electrons and their time evolution must be known. As part of the recent effort to understand this fast electron transport, a diagnostic has been installed on PBX-M to measure the electron cyclotron emission from the fast electrons. An oblique horizontal view of upshifted cyclotron emission in the midplane can give radial as well as velocity space information about the fast electrons. Emission in X mode frequencies refracted by the right-hand cutoff is radially localized. The observed emission at a specific frequency comes only from the radial region r_t_u_r_n=#0. Emission measured by this new diagnostic has been found to be radially localized as predicted. It is also expected that localized moments of the distribution ...
This report is devoted to the investigation of the influence of electron collisions and radial non-uniformity of plasma density on phase characteristics, spatial attenuation and wave field structure of slow symmetric electromagnetic waves that propagate along cylindrical waveguide structure. It has been shown that collision rate and radial non-uniformity of plasma density for various parameters of waveguide structure and dielectric affect essentially on the wave characteristics and consequently, on the parameters of gas discharge that is sustained by this wave. The results obtained are of large importance for the construction of the theory of gas discharges that are sustained by the surface electromagnetic waves.
The double-mode cepheid Y Car has been found to have a variable centre-of-mass velocity. Though the observations did not cover a cycle, an orbital period of about 400-600 days was estimated. Radial-velocity observations of this star have now been continued in order to derive the orbital elements. Observations were made with the photoelectric radial-velocity spectrophotometer at the coude focus of the 1.88-m reflector at Sutherland. The velocity system was standardized by frequent nightly observations of stars in the Mount Wilson catalogue with 'a'-quality radial velocities.
Role of ballooning effect in toroidal plasmas on the transient transport problems is investigated. Due to the mode localization along the magnetic field line, a meso scale appears in a radial correlation length of fluctuating fields. This scale length introduces the interference of the gradient and flux in different radial locations. For the fluctuation which gives the gyro-Bohm-like diffusion in a stationary state, this long radial correlation of the fluctuating field causes a fast propagation of response against a rapid transient perturbation. Upper bound of transient thermal diffusivity is derived. (author)
This paper attempts to explain the peculiarities of the radial-distribution function of metal glasses without involving ideas of the amorphous structure. On a computer, the radial atomic density for a spherical eutectic single crystal of the composition Fe/sub 84/C/sub 16/ of radius 15 A formed by alternating small crystals of e-Fe and Fe/sub 3/C of cubic form with the edge of the cube ca 10 A. For the sake of clarity, the diagram of such a quasisingle crystal is shown and has been given a cubic boundary. The change in the relationship between the heights of the subpeaks of the second maximum of the radial distribution function of atoms in the Fe-B glasses with a change in the concentration of boron can be explained by the change in the space group of the Fe/sub 3/B metastable boride which is formed in this system.
This paper introduces a novel three-phase power flow approach for unbalanced radial distribution systems. The proposed approach is developed based on the loop frame of reference, rather than the traditional bus frame of reference. On the basis of the loop frame of reference, a simple direct iterative method in impedance form is applied. Basic graph theory and injection current technique are also applied in the proposed approach. The clear theoretical foundation and the simple topology of the radial distribution network make the proposed method efficient and reliable. To demonstrate the better convergence performance and the efficiency of the proposed approach, four three-phase IEEE test feeders are used for comparisons. The test results show that the proposed method has robust convergence characteristics and high performance, especially for large-scale radial distribution systems. (author)
Molecular dynamics simulations have been carried out of the radial distribution function of the hard sphere fluid for a range of densities in the equilibrium fluid and just into the metastable region. The first derivative of the hard-sphere radial distribution function at contact was computed and its density dependence fitted to a simple analytic form. Comparisons were made with semi-empirical formulae from the literature, and of these the formula proposed by Tao et al (1992 Phys. Rev. A 46 8007) was found to be in best agreement with the simulation data, although it slightly underestimates the derivative at the higher packing fractions in excess of about 0.45. Close to contact, within a few per cent of the particle diameter, the radial distribution function can be represented well by a second order polynomial. An exponential function, which has some useful analytic features, can also be applied in this region.
The present emphasis on inherent safety for LMR designs has resulted in a need to represent the various reactivity feedback mechanisms as accurately as possible. The dominant negative reactivity feedback has been found to result from radial expansion of the core for most postulated ATWS events. For this reason, a more detailed model for calculating the reactivity feedback from radial core expansion has been recently developed for use with the SASSYS/SAS4A Code System. The purpose of this summary is to present an extension to the model so that it is more suitable for handling a core restraint design as used in FFTF, and to compare the SASSYS/SAS4A results using this model to the empirical correlation presently being used to account for radial core expansion reactivity feedback to FFTF.
A rare, true aneurysm of a branch of the right subclavian artery is described. Transcatheter coil embolization of the feeder artery was successful in obliterating blood flow into the aneurysm and the mass reduced in size. However, the aneurysm reenlarged over the next week of follow-up due to development and enlargement of the collateral vascular network. Extirpation of the aneurysm was performed. Histopathological examination revealed a true aneurysm. PMID:11833847
Hypoxia causes abnormal neonatal pulmonary artery remodeling (PAR) and inhibition of alveolar development (IAD). Transforming growth factor (TGF)-β is an important regulator of lung development...Full Text Available
ObjectiveWe wanted to evaluate the status of self-expandable nitinol stents implanted in the P2 and P3 segments of the popliteal artery in Korean patients.Materials...Full Text Available
Distribution of Lipiodol within hepatic tumor was evaluated using serial computed tomography. Imagistic Lipiodol transition into the tumor via hepatic artery was slower than that of water soluble contrast medium, spreading to central part first and turn to peripheral part of the tumor. This method was thought to be useful to clarify Lipiodol distribution in hepatic tumor and to decide the method or necessity of additional trans-arterial therapy. (author).
We report for the first time a case of a 54 years old man with a fatal motorcycle accident due to an external bleeding compression of left internal mammary artery graft to the left anterior descending...Full Text Available
Background:Acute Coronary Syndrome (ACS) can occur in patients with prior coronary artery bypass grafting (CABG). In the Gulf Registry of acute coronary events (Gulf RACE), we identified...Full Text Available
The Los Alamos Nuclear Material Accounting and Safeguards System (MASS) is a near-real-time accountability system for bulk materials, discrete items, and material undergoing dynamic processing. MASS has evolved from an eighty-column card based process control system to a very sophisticated computer system. The security of the MASS computer system is provide through various access controls. There are two kinds of access control to be addressed. They are physical access control to the hardware which make up the system, and access control to the software. There are many features which provide a measure of security to the hardware that will be discussed. Access to the software is controlled by a security password. Access to various transaction activities in the system is controlled through the level of MASS user privilege. Details of MASS user privilege will be ...
A new semi-empirical algorithm for the radial distribution of dose is compared with available data. The algorithm is used to calculate the inactivation cross section for dry enzymes and viruses using an extended target model of a 1-hit detector. Agreement with data is at about the 15% level, approximating the precision of the data itself. (author).
The fission gas xenon bonded in bubbles, in pore, and in the lattice of mixed carbide fuels is measured by electron-probe microanalysis. Radial xenon distribution and release curves are determined and are calibrated by gas chromatography of the bonded fission gas and by burnup analysis in the respective pin sections of the irradiation experiments FR2 6A and 6C, Mol 11/K 2, and DFR 330/1. The results are correlated to the microstructure of the fuel, bonding medium, temperature, and burnup. (Auth.).
Radial distribution functions of liquid sodium and caesium at 100"0C have been calculated by the method of molecular dynamics with interionic pair potentials derived from Heine-Abarenkov-Shaw type model potential. The results were found to be in good agreement with recent experimental data. (Auth.).
Substantial changes in the radial distribution function of amorphous Si films have been observed in neutron-diffraction studies. The spectra indicate changes in short-range order associated with an approx.11% modification in the bond-angle distribution width. The results allow the first direct comparison of structural and vibrational Raman probes of variations in local order in thin-film amorphous solids. Good agreement is obtained between the measured bond-angle variation and that based on Raman estimates.
The radial distribution function and the second virial coefficient of interacting bosons have been studied. The second virial coefficient has been deduced theoretically and is in good agreement with experimental values. The third virial coefficient has been calculated from the experimental values of the pressure. (Auth.).
In this paper, a new design methodology for determining the size, location, type and number of capacitors to be placed on a radial distribution system is presented. The objective is to minimize the peak power losses and the energy losses in the distribution system considering the capacitor cost. A sensitivity analysis based method is used to select the candidate locations for the capacitors. A new optimization method using a Genetic Algorithm is proposed to determine the optimal selection of capacitors. Test results have been presented along with the discussion of the algorithm.
A formula for calculating the Dirac S-matrix for central Lorentz scalar and vector potentials is derived by use of a new amplitude-phase method. The derivation also makes use of certain invariants of the reduced 2-spinor radial Dirac equations.
A formula for calculating the Dirac S-matrix for central Lorentz scalar and vector potentials is derived by use of a new amplitude-phase method. The derivation also makes use of certain invariants of the reduced 2-spinor radial Dirac equations.
... the major types of vascular access catheters: A peripherally inserted central catheter (PICC) is a long catheter that extends ... the procedure performed? A midline catheter and some peripherally inserted central catheter (PICC) lines may be inserted at your ...
Many healthcare organizations utilize network "firewalls" to protect their networks from being accessed by unauthorized external entities. These same firewalls are also often configured to deny access...Full Text Available
BackgroundPersonal health records (PHRs) provide patients with access to personal health information (PHI) and targeted education. The use of PHRs has the potential to improve a...Full Text Available
BackgroundThe survival of hemodialysis patients requiring dialysis depends on the long-term functioning and patency of the vascular access. Prosthetic vascular grafts are inevitably...Full Text Available
Femtocells are assuming an increasingly important role in the coverage and capacity of cellular networks. In contrast to existing cellular systems, femtocells are end-user deployed and controlled, randomly located, and rely on third party backhaul (e.g. DSL or cable modem). Femtocells can be configured to be either open access or closed access. Open access allows an arbitrary nearby cellular user to use the femtocell, whereas closed access restricts the use of the femtocell to users explicitly approved by the owner. Seemingly, the network operator would prefer an open access deployment since this provides an inexpensive way to expand their network capabilities, whereas the femtocell owner would prefer closed access, in order to keep the femtocell's capacity and backhaul to himself. We show mathematically and through simulations that the reality is more ...
This purpose of this paper is to describe the optimizing Peripherally Inserted Central Catheter (PICC) insertion, revising data collection strategies, estimating workloads, and calculating the financial savings generated by the vascular access nurse (VAN)...
Considering accessibility of the 3′UTR is believed to increase the precision of microRNA target predictions. We show that, contrary to common belief, ranking by the hybridization energy or by...Full Text Available
ObjectiveTo estimate the joint effect of a multifaceted access intervention on primary care physician (PCP) productivity in a large, integrated prepaid group practice.Data...Full Text Available
sharing data and computational resources, and accessing information in digital libraries." Bill Wulf (1989) In a Collaboratory, the presentation/meeting concept embodied...
... Uninterrupted access to and use of critical infrastructure in the Arabian Gulf region are key to the successful prosecution of the Global War on Terror ...
Distribution of restricted information (see wikileaks); Restricting Access to as advertised open discussion groups. Gives impression of consensus by ...
An important goal for digital libraries is to enable researchers to more easily explore related work. While citation data is often used as an indicator of relatedness, in this paper we demonstrate that digital access records (e.g. http-server logs) can be used as indicators as well. In particular, we show that measures based on co-access provide better coverage than co-citation, that they are available much sooner, and that they are more accurate for recent papers.
To reduce the number of regular break-ins on CERN machines due to passwords exposed on the network in clear text, OFF-SITE FTP ACCESS TO CERN WILL BE BLOCKED in the CERN firewall from: Tuesday 20th January 2004 If you use ftp to access CERN computers from outside CERN then please see the link below for alternative access means and further advice: http://cern.ch/security/ftp Denise Heagerty, CERN Computer Security officer, Computer.Security@cern.ch
To reduce the number of regular break-ins on CERN machines due to passwords exposed on the network in clear text, OFF-SITE FTP ACCESS TO CERN WILL BE BLOCKED in the CERN firewall from: Tuesday 20th January 2004 If you use ftp to access CERN computers from outside CERN then please see the link below for alternative access means and further advice: http://cern.ch/security/ftp Denise Heagerty, CERN Computer Security officer, Computer.Security@cern.ch
... 1 (2008) Algorithms - Open Access Journal Algorithms (ISSN 1999-4893; CODEN: ALGOCH), an open access journal of computer science, theory, methods and interdisciplinary applications, data and information systems, software engineering, artificial intelligence, automation and control systems, is published online quarterly by MDPI. - free for readers, with low publishing fees paid by authors or their institutions High visibility: indexed in leading indexing and abstracting databases....
Lobar emphysema is an uncommon cause of respiratory distress in infancy. Congenital heart disease is seen in about 20% of the patients with infantile (congenital) lobar emphysema. We described six infants with lobar emphysema. In three of them a congenital heart disease was demonstrated by cardiac catheterization and cineangiography; two had a tetralogy of Fallot with right aortic arch and the third infant a ventricular septal defect. The pulmonary angiography showed stretching of the arteries with very poor filling of the peripheral arteries and a characteristic smaller pulmonary vein in the affected lobe. In all the six patients the pulmonary artery pressure was normal. All the patients underwent lobectomy with good results. We feel that a preoperative cardiac catheterization and cineangiography is of value in this very sick group of infants. (orig.).
The prospective study includes 25 patients without pathology of the femoral head for the evaluation of the normal femoral head perfusion. In addition 34 patients with femoral head necrosis underwent i.a. DSA preoperatively before pedicled pelvic bone grafting. 15 patients after pelvic bone graft operation and 7 patients with medial femoral head fracture were also examined via superselective DSA. In cases with femoral head necrosis a rarefaction or interruption of the rami nutricii proximales, or an occlusion of the medial circumflex femoral artery were observed. Patients with medial femoral neck fracture showed an interruption of the rami nutricii proximales of the femoral head. Postoperative DSA - after pedicled pelvic bone graft - revealed a regular arterial graft perfusion in 82%. (orig.).
Soluble TWEAK is a member of the TNF-alpha family of cytokines that has been shown to predict mortality in patients with heart failure. Pulmonary artery hypertension is a devastating disease, in which right ventricular function has been shown to be the major determinant of prognosis. In this hypothesis-generating study, we sought to evaluate the potential usefulness of sTWEAK in the prediction of disease severity in patients with pulmonary artery hypertension. We therefore conducted a retrospective analysis of sTWEAK serum levels in 95 stable patients with PAH. For all patients data on hemodynamic parameters, biomarkers and functional exercise tests were available. Compared to controls, patients with PAH showed significantly decreased levels of sTWEAK [median 314?pg/ml (interquartile range...
The distribution of Lipiodol in the liver and lungs following arterial or portal injection was studied in normal (n=55) and cirrhotic rats (n=20). Using magnified xeroradiography and radioisotope labeled tracers, it was found that Lipiodol was deposited mainly in the liver and lung after either arterial or portal administration. In control rats after arterial injection, deposits in the lung peaked after 2 hours and gradually declined over 48 hours; whereas after portal injection, the deposit steadily increased for 48 hours. Twenty-five percent of cirrhotic rats demonstrated a Lipiodol-induced miliary pattern in the lung. An increased number of portosystemic shunts in cirrhotic rats was also noted. These results suggest that cirrhosis of the liver may be a potential risk factor for developing pulmonary complications after Lipiodol administration. (orig.).
This study examined whether elevated intravascular pressure stimulates asynchronous Ca2+ waves in cerebral arterial smooth muscle cells and if their generation contributes to myogenic tone development. The endothelium was removed from rat cerebral arteries, which were then mounted in an arteriograph, pressurized (20 100 mmHg) and examined under a variety of experimental conditions. Diameter and membrane potential (VM) were monitored using conventional techniques; Ca2+ wave generation and myosin light chain (MLC20)/MYPT1 (myosin phosphatase targeting subunit) phosphorylation were assessed by confocal microscopy and Western blot analysis, respectively. Elevating intravascular pressure increased the proportion of smooth muscle cells firing asynchronous Ca2+ waves as well as event frequency. C...
Fuji Computed Radiography (FCR) was evaluated for detection of intracardiac calcification as compared with conventional radiography in 77 patients. Intracardiac calcification was found in 37 patients (left coronary artery: 31, right coronary artery: 11, valve: 9) on cine-fluorography. The sensitivity for detecting these calcified foci with FCR was higher than conventional screen-film method. Especially, sensitivity for detecting left coronary artery calcification with FCR was significantly higher than conventional method (71 %, 32 %) (p < 0.01), Fine anatomical details of calcification were well shown on FCR. Chest radiography using FCR is of great use for detection of intracardiac calcification. (author).
PurposeTo evaluate the safety and effectiveness of the Zilver vascular stent in the treatment of de novo or restenotic lesions in the external and common iliac arteries.Materials and MethodsRegardless of the results of an initial percutaneous transluminal angioplasty (PTA), 151 consecutive patients were implanted with Zilver vascular stents (Cook, Bloomington, Ind) in up to two stenotic (?10 cm) or occluded (?5 cm) atherosclerotic lesions of the external or common iliac arteries. The primary endpoint was the rate of major adverse events within 9 months after the procedure. Major adverse events were defined as death, myocardial infarction, target lesion revascularization, and limb loss. Secondary endpoints included acute procedural success, 30-day clinical success, 9-month pat...
Difficulty in recalling the names of people is very common in the early stages of Alzheimer's disease and in mild cognitive impairment (MCI). However, it is not known whether the difficulty in naming people in MCI reflects problems associated with lexical access or with semantic access. The aims of the present study were to investigate semantic and phonological access to proper names by use of a Tip-of-the-tongue (TOT) task in individuals with multidomain amnestic MCI, individuals with amnestic MCI, and healthy controls, as well as to study the relationships between TOT production and performance in a free recall verbal memory test. In the individuals with multidomain amnestic MCI, the main process affected was phonological access; failures in phonological access were related to deficits i...
We combine establishment-level employment data with trade data by port to examine the impact of accession to the European Economic Community on the spatial distribution of UK manufacturing. We test the predictions from economic geography models of how external trade affects the spatial distribution of employment. We treat accession as a natural experiment which helps mitigate problems of endogeneity. Our results suggest that accession changed the country composition of trade and via the port composition induced an exogenous shock to different locations. In line with theory, we find that better access to export markets and intermediate goods increase employment while increased import competition decreases employment.
It has been widely assumed that South Africa has achieved universal basic education. Through an analysis of the 2001 census and two national enrolment datasets rather than statistical projections, this study re-examines this assumption and provides new estimates of enrolment levels in primary, basic and secondary education. Using GER, NER, and ASER indicators, disaggregated by gender and province, the study shows that access to education in South Africa is not as widespread as published sources note. While statistics show that national access levels are lower than prevailing estimates, the relatively high levels of access in some of the most disadvantaged provinces suggest the need to re-evaluate assumptions about targets for universal access for developing regions. In addition, the analysis reveals South Africa's unexpected and provocative gendered patterns of access and ...
A relocatable storage magazine apparatus for storing and retrieving explosives and ordnance and for partially containing and attenuating the blast, conflagration and flying debris from an accidental explosion is described comprising: (a) a container having an access hole; (b) a debris trap attached to the container, the debris trap communicating with said container via the access hole, said debris trap having vent holes for venting the pressure of an explosion from said debris trap to the atmosphere; (c) means for covering said access hole; (d) means for suspending explosives and ordnance from the covering means; (e) means for entering the storage magazine to store and retrieve explosives and ordnance; (f) means for retaining said covering means in a position above the access hole wherein said explosives and ordnance are accessible from the entering means.
This study examines the effects of intravenous infusion of adenosine and sublingual nitroglycerin on coronary angiograms obtained by current-generation multidetector computed tomography. We assessed...Full Text Available
Treatment with sorafenib prolongs both the median survival and time to progression by nearly 3 months in patients with advanced hepatocellular carcinoma. Although the effects of combining sorafenib...Full Text Available
Therapeutic embolization is defined as the voluntary occlusion of one or several vessels, and this is achieved by inserting material into the lumen to obtain transient or permanent thrombosis in the...Full Text Available
Transcatheter arterial chemoembolization (TACE) has become the standard treatment modality for unresectable hepatocellular carcinoma (HCC). Nonetheless, the clinical outcomes in patients with unresectable...Full Text Available
Splice products of the Kiss1 protein (kisspeptins) have been shown to be involved in a diverse range of functions, including puberty, metastasis and vasoconstriction in large human arteries. Circulating...Full Text Available
... CT angiograph for the peripheral rteries. a beautiful 3D-vision on the structures inside e chest. Okay. ... have an angled camera here. This is a 3D camera, and the surgeon has got th What ...
This is a report of surgical treatment of thoracoabdominal aortic aneurysms and aneurysms of the abdominal aorta from which the visceral vessels arise during the 18 year period from April 5, 1960,...Full Text Available
Compliance mismatch is a significant challenge to long-term patency in small-diameter bypass grafts because it causes intimal hyperplasia and ultimately graft occlusion. Current engineered grafts...Full Text Available
Background and objectives: Patients receiving dialysis have a high burden of cardiovascular disease. Some receive coronary artery revascularization but the optimal method is controversial.Design,...Full Text Available
Left ventricular aneurysm (LVA) is one of the most important complications of myocardial infarction LVA is strictly defined as a distinct area of abnormal left ventricular diastolic contour with systolic...Full Text Available
The use of percutaneous transluminal coronary angioplasty is limited by procedural complications and the serious drawback of restenosis, but some new techniques have been developed in an attempt to...Full Text Available
OBJECTIVE—Identification of arterial genes and pathways altered in obesity and diabetes.RESEARCH DESIGN AND METHODS—Aortic gene expression profiles of...Full Text Available
A 57-year-old man with a history of coronary artery disease and placement of an implantable cardioverter-defibrillator presented at our emergency room with an anterior ST-elevation myocardial infarction....Full Text Available
Myosin phosphatase target subunit 1 (MYPT1) is the regulatory subunit of myosin light chain phosphatase (MLCP). It plays a critical role in vasodilatation induced by cGMP-elevating agents such as nitric...Full Text Available
The computational fluid dynamics methods for the limited flow rate and the small dimensions of an intracranial artery stenosis may help demonstrate the stroke mechanism in intracranial atherosclerosis....Full Text Available
BackgroundVascular stents are small tubular scaffolds used in the treatment of arterial stenosis (narrowing of the vessel). Most vascular stents are metallic and are deployed either...Full Text Available
Endovascular surgery is a new multidisciplinary field that applies the recently innovated techniques of angioscopy, intraluminal ultrasound, balloon angioplasty, laser, mechanical atherectomy, and stents....Full Text Available
ObjectivesWe undertook a meta-analysis to assess outcomes for drug-eluting (DES) and bare metal stents (BMS) in percutaneous coronary intervention (PCI) for unprotected...Full Text Available
BackgroundVariable platelet response to clopidogrel has been widely observed. Studies have shown that the mean aggregation response to clopidogrel can be changed...Full Text Available
We sought to determine whether the third component of complement (C3) is localized in ischemic baboon myocardium after coronary artery ligation. Furthermore, we assessed the effects of prior C3 depletion...Full Text Available
Characteristics relevant to cardiovascular disease, including anthropometry, arterial blood pressure, serum cholesterol levels, chest radiography and electrocardiography, were investigated in a survey...Full Text Available
Carotid artery stenosis is a major risk factor for stroke, and treatments for this condition to decrease the risk of stroke include medical therapy, carotid endarterectomy (CEA), and, more recently,...Full Text Available
The biomechanical nature of the arterial system and its major disease states provides a series of challenges to treatment strategies. Endovascular device design objectives have mostly centered on short-term...Full Text Available
Nitric oxide (NO)-based therapies effectively inhibit neointimal hyperplasia in animal models of arterial injury and bypass grafting, but are not available clinically. We created a simple, effective,...Full Text Available
Unruptured cerebral aneurysms often present with neuro-ophthalmological symptoms but ocular autonomic involvement from an aneurysm of the posterior circulation has not previously been reported. A patient...Full Text Available
Visual assessment of the degree of renal artery stenosis on renal arteriography has a large inter- and intraobserver variability. This degree is usually estimated by the ratio between the most narrowed...Full Text Available
Background:Erectile dysfunction in type-2 diabetes may be an independent marker for coronary artery disease. Present study was undertaken to investigate whether type-2 diabetic...Full Text Available
Antiplatelet resistance has been proposed as a possible mechanism to explain recurrent cardiovascular events in patients who have coronary artery disease and who are undergoing dual antiplatelet therapy....Full Text Available
Atherosclerosis is an inflammatory process leading to enhanced cellular proliferation, apoptosis, and vasa vasorum (VV) neovascularization. While both diabetes mellitus (DM) and hypercholesterolemia...Full Text Available
BackgroundPregnancies complicated by abnormal umbilical artery Doppler blood flow patterns often result in the baby being born both preterm and growth-restricted. These babies are...Full Text Available
Tracheo-arterial fistula after tracheostomy causing massive haemorrhage is fortunately rare, but can be serious and often fatal. Brachiocephalic trunk is commonly at risk of erosion because of its close...Full Text Available
BACKGROUNDOff-pump coronary artery bypass (OPCAB) surgery is associated with a hypercoagulable state in which the platelet thrombin receptor, protease-activated receptor-1...Full Text Available
We demonstrate a novel cross-sectional deformation, called the radial corrugation, of multi-walled carbon nanotubes (MWNTs) under hydrostatic pressure. Theoretical analyses based on the continuum elastic approximation have revealed that MWNTs consisting of more than ten concentric walls undergo elastic deformations at critical pressure Formula Not Shown , above which the circular shape of the cross-section becomes radially corrugated. Various corrugation modes have been observed by tuning the innermost tube diameter and the number of constituent walls, which is a direct consequence of the core-shell structure of MWNTs. Cross-sectional views of MWNT under high hydrostatic pressure: elliptic deformation with the mode index n = 2 (left), and radial corrugations with n = 5 (center), and n = 6 ...
The possibility of controlling the radial electric field of toroidal plasmas by injecting high energy electrons along the reversible loss cone orbit of the helical magnetic traps is investigated. It is well known that the radial electric field plays an important role in the confinement improvement scenario especially in the low collisional regime under the physics picture of neoclassical theory. For this purpose, it is made clear that the most suitable particles are transit particles, which show a transition from helically trapped orbits to blocked ones. It is also found that a parallel AC electric field launched from outside assists this transition and makes it possible for particles to penetrate deeply into the plasma. In addition we clarify that the viscosity of the plasma coupled with the helical field configuration provide a bifurcation of plasma states and its stable solution results in confinement improvement. (author)
The present paper describes the application of the commercial CFD-code FLUENT 6.1 to the numerical simulation of the flow field in a high specific speed radial fan. Two-dimensional as well as three-dimensional computations are performed using the steady 'Frozen-Rotor method' as well as the unsteady 'Sliding-Mesh method'. The predicted performance curves of the radial fan are compared with the results obtained from measurements on a test stand. Due to the relatively low computation times, the 'Frozen-Rotor method' can be used routinely for design purposes. The results of this approach can be improved if the leakage flow through the gap between the inlet nozzle and the impeller is taken into account. (orig.)
Dark matter particles form halos that contribute the major part of the mass of galaxy clusters. The formation of these cosmological structures have been investigated both observationally and in numerical simulations, which have confirmed the existence of a universal mass profile. However, the dynamic behaviour of dark matter in halos is not as well understood. We have used observations of 16 equilibrated galaxy clusters to show that the random velocities of dark matter particles are larger on average along the radial direction than along the tangential, and that the magnitude of this velocity anisotropy is radially varying. Our measurement implies that the collective behaviour of dark matter particles is fundamentally different from that of normal particles and the radial variation of the anisotropy velocity agrees with the predictions of numerical simulation.
New non-stationary non-contracted form of the erosive radially-slotted discharge as a thin round sheet with the current of the azimuth direction have been discovered, its existence beings stipulated by a radial transport-wave fluxes. Characteristic features of this discharge is self-confinement of the discharge current magnitude, corresponding decrease of the current pulse duration and occurrence of an energy and substance ejection with rather unusual properties. Measurements of kinetics of the discharge current, the plasma radiation intensity and an electrical probe signal, as well as the transmission electron microscope investigations of characteristic aerodisperse aggregates arising the erosive phase, have been carried out. The probe signal duration was about 10 times greater than that of the current; its kinetics was complicated suggesting existence in the slot of two components with fundamentally different properties and states of the ...
The separator can be used for electrical separation of the drilling string used as the channel of communication with transmission of face information. It contains upper and lower metal conductors electrically insulated from each other by an insulator made of layered polymer composite material. In order to improve reliability of the connection of the conductors to the insulator and reduce the metal consumption on the ends of the conductors that come into contact with the insulator there are graduated niches with radial projections. The latter form jointly with the layers of the insulator a crown-radial-multiple stage undetachable connection. The niches decreases from the outer diameter of the conductors to the inner. The insulator has additional layers made of high-module fibers of carbon or boron which cover the radial projections in stages.
Radial sonic crystals (RSC) are fluidlike structures infinitely periodic along the radial direction that verify the Bloch theorem and are possible only if certain specially designed acoustic metamaterials with mass density anisotropy can be engineered (see Torrent and Sanchez-Dehesa 2009 Phys. Rev. Lett. 103 064301). A comprehensive analysis of two-dimensional (2D) RSC shells is reported here. A given shell is in fact a circular slab with a central cavity. These finite crystal structures contain Fabry-Perot-like resonances and modes strongly localized at the central cavity. Semi-analytical expressions are developed to obtain the quality factors of the different resonances, their symmetry features and their excitation properties. The results reported here are completely general and can be extended to equivalent 3D spherical shells and to their photonic counterparts.
The energy deposited by the passage of a single, energetic, heavy-ion through a semiconductor produces dense electron-hole (eh) pair concentrations near the ion trajectory. The size, shape, and charge density of an ion track represent critical parameters for many models of single event phenomena. The authors describe the design and uses of possible semiconductor test structures for measuring the initial radial distribution of charge and subsequent charge transport in a high energy, heavy-ion track. Numerical simulations show how the test structure can resolve different radial distributions of charge within an ion track. The test structure simulations also show the importance of accurately representing ion track structure in single event effects simulations.
Isolated laevocardia combined with corrected transposition of the great arteries and complete situs inversus is rare. Due to discordant interrelationships between atria and ventricles and between ventricles and great arteries, both anomalies result in a normal circulation. In the presented case no associated cardiac malformations were present and the 55-year-old woman remained symptom-free for a long time until she developed an acquired valve disease. A systematic approach to chamber localisation in complex morphologic lesions of the heart is reviewed, and the value of CT, which can be applied successfully in older children and adults is demonstrated. (orig.).
The incidence of hepatocellular carcinoma (HCC) is increasing in developed countries and the general status of HCC patients is now by far better than a few years ago, allowing physicians to propose some different treatments of these patients. Among these treatments, intra-arterial injection of 131-iodine-labelled Lipiodol could be used in palliative, curative or adjuvant settings. After a brief summary of the modalities of this treatment, requiring the collaboration of Gastro-enterologists, Oncologists, Radiologists and Nuclear Medicine physicians, the different possibilities of therapeutic uses of this new approach are described and an outlook of these developments is proposed. (author)
Purpose: To evaluate MR artifacts of carotid artery stents and to optimize stent properties and sequence parameters. Material and Methods: Four carotid artery stents - Wallstent (mediloy), Precise (nitinol), ACCULINK (nitinol) and a stent prototype (nitinol) - were investigated in a flow model of the cervical vessels. The model was made of silicon tubing and a flow pump that produces realistic flow curves of the carotid artery. To investigate the effects of magnetic susceptibility and radiofrequency induced shielding artifacts, turbo spin echo and gradient echo sequences as well as CE-MRAs were measured. To improve the visualization of the stent lumen in a CE-MRA, flip angle as well as geometry and covering of the stent prototype were altered. Results: Susceptibility artifacts in stents of the carotid artery only influence the lumen visualization at the proximal and distal end of the braided mediloy ...
Homologous and heterologous arterial segments were implanted in Fisher rats subcutaneously for the purpose of examining the antibody titer of the recipients' serum after implantation by means of the immune-adherence hemagglutination method. The antibody titer after implantation both of homologous and heterologous grafts decreased to 1/8 by 2.0 million (M) rads irradiation of high voltage cathode rays. The results suggested that high voltage cathode ray irradiation was not enough for heterologous graft to suppress its tissue reaction. Homografts taken from dogs 3 or 6 hours after sacrifice were irradiated with 2.0 M rads and transplanted in canine carotid artery using the technic of end-to-end anastomosis. Angiograms 6 months after operation revealed excellent patency rate in all the grafts of 28 dogs. furthermore, findings of the grafts from 1 week to 5 years after operation on scanning and transmission electron microscopies were ...
Homologous and heterologous arterial segments were implanted in Fisher rats subcutaneously for the purpose of examining the antibody titer of the recipients' serum after implantation by means of the immune-adherence hemagglutination method. The antibody titer after implantation both of homologous and heterologous grafts decreased to 1/8 by 2.0 million (M) rads irradiation of high voltage cathode rays. The results suggested that high voltage cathode ray irradiation was not enough for heterologous graft to suppress its tissue reaction. Homografts taken from dogs 3 or 6 hours after sacrifice were irradiated with 2.0 M rads and transplanted in canine carotid artery using the technic of end-to-end anastomosis. Angiograms 6 months after operation revealed excellent patency rate in all the grafts of 28 dogs. furthermore, findings of the grafts from 1 week to 5 years after operation on scanning and transmission electron microscopies were evaluated. ...
We obtain the radial Dirac equations for the Plebanski metric and transform these equations into one-dimensional wave equations. Finally we conclude with the result that the electron and the neutrino fields are not superradiant.
The present emphasis on inherent safety for liquid-metal reactor designs has resulted in a need to represent the various reactivity feedback mechanisms as accurately as possible. The dominant negative reactivity feedback has been found to result from radial expansion of the core for most postulated anticipated transient without scram events. For this reasons, a more detailed model for calculating the reactivity feedback from radial core expansion, including subassembly bowing has been recently developed for use with the SASSYS/SAS4A code system. The purpose of this summary is to present an extension to the model so that it is more suitable for handling a core restraint design as used in the Fast Flux Test Facility (FFTF), and to compare the SASSYS/SAS4A results using this model to the empirical correlation presently being used to account for radial core expansion reactivity feedback in the FFTF.
Extensive investigations and detailed analysis of the failure reason of 9DVN002ZV fan in Daya Bay Nuclear Power Station showed that the fan destroy was caused by the failure of non-drive end bear. The direct cause of this bearing' failure was its improper assembly caused by improper maintenance procedure, and the root cause was too small internal radial clearance after mounting. The factor affecting bearing internal radial clearance, the relationship between clearance and operating life time and fan failure process were discussed. (authors)
The title invention aims at a vibrations-free running of the flywheel to realize a high speed (18,000-20,000 revolutions per minute). The flywheel consists of a case which holds a central stator, a rotor and two ball-bearings. The ball-bearings have a first radial stiffness and are placed in between the rotor and an upper, respectively lower support bearer. The support bearers are supported on the stator with a second radial stiffness. The top and the bottom of the stator is connected to the case by means of a support with a third stiffness. 6 figs.
A clear and reproducible transition to a regime with an improved particle confinement is routinely observed on the CASTOR tokamak, if the biasing electrode is inserted deep enough into the plasma (r/a?0.5) and biased up to +250 V. The steepening of the radial profiles of the plasma density and potential demonstrate the formation of a transport barrier just inside the last closed flux surface. Fast relaxations of the edge plasma parameters, with a frequency of about 10 kHz, are observed when the average radial electric field within the barrier prevails values of about 20 kV/m. A detailed analysis of the spatial-temporal behaviour of these relaxations is presented.
XAFS data of metallic glass Al_0_._9_1La_0_._0_9 and a crystalline phase Al_1_1La_3 formed by annealing of the glass were measured at the La L_3 edge at T=12 K and analyzed using the radial distribution function method. The shortest La-Al distance appeared to be distinctively smaller within the glass than in the crystal. This difference decreases the disparity in size of La and Al in the alloy, allowing their mixing in the glassy state. ((orig.)).
Longitudinal space charge (LSC) force can be a main effect driving the microbunching instability in the linac for an x-ray free-electron laser (FEL). In this paper, the LSC-induced beam modulation is studied using an integral equation approach that takes into account the transverse (radial) variation of LSC field for both the coasting beam limit and bunched beam. Changes of beam energy and the transverse beam size can be also incorporated. We discuss the validity of this approach and compare it with other analyses as well as numerical simulations.
A sample of 41 radio-galaxies with 13.0<=msub(corr)<=15.5 has been analyzed to test the angular redshift anisotropy discovered on Sc I galaxies by Rubin, Rubin and Ford (1973). The sample does not present their anisotropy but contains an even more curious distribution of radial velocities which suggests that the Rubin-Ford effect results from an anomalous redshift of light when it travels through clusters of galaxies. (Auth.).
The outward radial expansion of a free liquid annulus is a common problem of both earlier and current ICF blanket design. Whether the annulus fractures or not depends on the internal pressure and surface stability. In this paper a model based on incompressible cylindrically symmetric flow is used to get a theoretical solution similar to that of the Rayleigh's solution for bubble dynamics. The pressure inside the annulus is found positive all time but the peak is lowering during the expansion. Besides, both surfaces are Taylor stable during such motion. Thus, it is concluded that an annulus in outward radial motion will not cavitate or breakup.
Differential cross sections have been measured for the elastic and inelastic scattering of 104 MeV alpha-particles from /sup 90/,/sup 92/Zr. The experimental data are analyzed in terms of coupled channels on the basis of a flexible anharmonic vibrator model and using different parametrizations of the radial shape of the extended optical potential. The results favour the squared Saxon-Woods type for the real part. Additionally to a radial momentum analysis of the real potentials a semimicroscopic folding model has been invoked for extracting isoscalar quadrupole and hexadecapole transition rates.
Differential cross sections have been measured for the elastic and inelastic scattering of 104 MeV alpha-particles from "9"0,"9"2Zr. The experimental data are analyzed in terms of coupled channels on the basis of a flexible anharmonic vibrator model and using different parametrizations of the radial shape of the extended optical potential. The results favour the squared Saxon-Woods type for the real part. Additionally to a radial momentum analysis of the real potentials a semimicroscopic folding model has been invoked for extracting isoscalar quadrupole and hexadecapole transition rates. (orig.).
Having always been at the forefront of information management and open access, High-Energy Physics (HEP) proves to be an ideal test-bed for innovations in scholarly communication including new information and communication technologies. Three selected topics of scholarly communication in High-Energy Physics are presented here: A new open access business model, SCOAP3, a world-wide sponsoring consortium for peer-reviewed HEP literature; the design, development and deployment of an e-infrastructure for information management; and the emerging debate on long-term preservation, re-use and (open) access to HEP data.
... Accession Number : ADD815206. Title : Waterjet Cutting System Adds Value to Titanium Parts. Descriptive Note : Journal article. Corporate Author : ...
... Accession Number : AD0749455. Title : Uptake and Retention of Adenine Moiety by Stored Human Red Blood Cells. Descriptive Note : Interim rept.,. ...
Although clinic environments are a primary location for exchanging information with clinicians, patients experience these spaces as harsh environments to access, use, exchange, and manage information....Full Text Available
As the amount of biological data grows, so does the need for biologists to store and access this information in central repositories in a free and unambiguous manner. The European Bioinformatics Institute...Full Text Available
Background Stimulated by the concept of Natural Orifice Transluminal Endoscopic Surgery (NOTES), minimizing the access even further has become a new trend in minimally invasive surgery. We compare our recently described new method of endoscopic single-access adrenalectomy with the conventional retroperitoneoscopic approach in a matched-pairs study. Methods Fifty single-access retroperitoneoscopic adrenalectomies (SARA) were performed in 47 selected patients suffering from Conn?s adenomas (n?=?20), pheochromocytomas (n?=?15), Cushing?s adenomas (n?=?6), and other diseases (n?=?6). For SARA, a single 2-cm skin incision beneath the 12th rib was used. Following creation of the retroperitoneal space with the rigid endoscope, dissection was carried out single-handed. Another 47 patients served a...
Over the past three decades, rising competition from television and other new media prompted the FCC to ease the responsibilities of radio stations to maintain extensive records of issues programming, while retaining the responsibility of stations to provide ready public access to records. This study investigated the availability of Issues-Programs Lists in nearly 100 Missouri radio station Public Files. One in five randomly sampled stations failed to produce access to Lists upon demand as required under federal law. Noncompliance themes include: Inability to access Public Files within 20 minutes of face-to-face requests; station personnel with limited or no knowledge of Files; denial of access to Files and Lists (i.e., verbal refusals, locked studio doors); and incomplete Files. The rate ...
The Python programming language is steadily increasing in popularity as the language of choice for scientific computing. The ability of this scripting environment to access a huge code base in various...Full Text Available
may experience difficulty opening the Facebook page due to current HHS policy and network security that blocks access to the site. Site Map - Contact Us - Linking to USPHS.gov -...
... Accession Number : ADD135818. Title : Performance of Titanium in Flue Gas Desulfurization Scrubber Systems,. Descriptive Note : Journal Article,. ...
The tremendous growth of wireless technologies has introduced the potential of continuous service adaptation to the users' needs by giving them the ability to be able to select and access the proper network based on different criteria. Moreover, next generation wireless networks have been designed to provide support for multimedia services, with different traffic characteristics and different Quality of Service (QoS) guarantees. However, the expansion of Wireless Local Area Networks (WLANs) and Worldwide Interoperability for Microwave Access (WiMAX) networks poses new research era in the decision of the access network selection. In this paper, the existing access network selection schemes are classified into three categories: the network-centric, the user-centric and the collaborative sche...
... Accession Number : ADD431225. Title : Influence of Fiber Loading on Thermal Ablation of PTFE,. Corporate Author : Personal Author(s) : Letson,KN. ...
Background An increasing number of people have access to the Internet, and more people are seeking tobacco cessation resources online every year. Despite the...Full Text Available
The eye is an easily accessible, highly compartmentalised and immune-privileged organ that offers unique advantages as a gene therapy target. Significant advancements have been made in understanding...Full Text Available
SummaryNineteenth-century Vienna is well known to medical historians as a leading centre of medical research and education, offering easy access to patients and corpses to students...Full Text Available
High-throughput genomic and proteomic technologies have generated a wealth of publicly available data on ageing. Easy access to these data, and their computational analysis, is of great importance in...Full Text Available
... Uninterrupted access to and use of critical infrastructure in the Arabian Gulf region are key to the successful prosecution of the Global War on Terror ...
respectively. This is a NASA and GSFC requirement to help ensure our computer and network security on center. In the near future, ftp access, with the exception of anonymous ftp of...
The aim of this study was to document vascular complications that occurred following cadaveric and living donor kidney transplants in order to assess the overall incidence of these complications at our center as well as to identify possible risk factors. In a retrospective cohort study, 1500 consecutive renal transplant recipients who received a living or cadaveric donor kidney between December 1988 and July 2006 were evaluated. The study was performed at the Nemazee Hospital, Shiraz, Iran. The assessment of the anatomy and number of renal arteries as well as the incidence of vascular complications was made by color doppler ultrasonography, angiography, and/or surgical exploration. Clinically apparent vascular complications were seen in 8.86% of all study patients (n = 133) with the most frequent being hemorrhage (n = 91; 6.1%) followed by allograft renal artery stenosis (n = 26; 1.7%), renal artery thrombosis (n = 9; ...
This study was designed to identify abnormalities in the hepatic-arterial/portal-venous scintiangiogram (SA) in alcoholic hepatitis (AH). SA's were performed in 35 patients with acute alcoholic hepatitis (AAH), 8; acute alcoholic hepatitis superimposed on cirrhosis (A/C), 14; and cirrhosis (C), 13. Posterior flows were done with a bolus of 10 mCi Tc-99m sulfur colloid with computer time-activity curves over the liver and left kidney. Curves were analyzed for per cent of hepatic arterial (HA) and portal venous contribution using the slope ratio method. Hepatic arterialization was estimated from the angle of the HA component of the curve. Reversal of the relative contribution of the hepatic and portal components of total flow were seen in all groups. Although quite severe in AH, the degree of reversal could not be used to differentiate among the groups. The average HA angle in AAH was 48.3 +- 8.1, in A/C 41.5 +- ...
This study was designed to identify abnormalities in the hepatic-arterial/portal-venous scintiangiogram (SA) in alcoholic hepatitis (AH). SA's were performed in 35 patients with acute alcoholic hepatitis (AAH), 8; acute alcoholic hepatitis superimposed on cirrhosis (A/C), 14; and cirrhosis (C), 13. Posterior flows were done with a bolus of 10 mCi Tc-99m sulfur colloid with computer time-activity curves over the liver and left kidney. Curves were analyzed for per cent of hepatic arterial (HA) and portal venous contribution using the slope ratio method. Hepatic arterialization was estimated from the angle of the HA component of the curve. Reversal of the relative contribution of the hepatic and portal components of total flow were seen in all groups. Although quite severe in AH, the degree of reversal could not be used to differentiate among the groups. The average HA angle in AAH was 48.3 +- 8.1, in A/C 41.5 +- 10.6, and in ...
We wanted to evaluate the status of self-expandable nitinol stents implanted in the P2 and P3 segments of the popliteal artery in Korean patients. We retrospectively analyzed 189 consecutive patients who underwent endovascular treatment for steno occlusive lesions in the femoropopliteal artery from July 2003 to March 2009, and 18 patients who underwent stent placement in popliteal arterial P2 and P3 segments were finally enrolled. Lesion patency was evaluated by ultrasound or CT angiography, and stent fracture was assessed by plain X-rays at 1, 3, 6 and 12 months and annually thereafter. At the 1-month follow-up, stent fracture (Type 2) was seen in one limb (up to P3, 1 of 18, 6%) and it was identified in seven limbs at the 3-month follow-up (Type 2, Type 3, Type 4) (n = 1: up to P2: n = 6: P3). At the 6-month follow-up, one more fracture (Type 1) (up to P3) was noted. At the 1-year follow-up, there were no additional stent ...
The feasibility of self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty was assessed. Options for lower limb percutaneous revascularization are limited, especially for complex vessel obstruction. Depending on the lesion and the experience of the interventionalist, the failure rate of balloon angioplasty (PTA) ranges between 10 and 40%. Until recently, no self-expanding stent for the use in the infragenicular arteries was available. This is the first report of the results for 18 consecutive patients who received 4F sheath compatible self-expanding nitinol stents following unsuccessful PTA or early restenosis. Twenty-four stents were implanted in 21 lesions for various indications residual stenosis >50% due to heavy calcification, flow-limiting dissection, occluding thrombus resistant to thrombolyis, thrombaspiration, and PTA, and early restenosis after previous PTA. Stent ...
Hemodynamic characteristics were studied by using in vivo vascular imaging techniques in 17 resected early stage hepatocellular carcinoma (e-HCC) by comparing them with 49 resected advanced HCCs (ad-HCC) less than 3 cm in diameter. In this study, e-HCC was defined as the nodule being uniformly composed of well-differentiated HCC or adenomatous hyperplastic nodule containing well-differentiated HCC foci within the nodule. In vivo vascular imaging techniques are as follows; US angiography with intraarterial CO{sub 2} microbubbles were performed to assess the tumor arterial vascularity, and CT during arterial portography (CTAP) was performed to assess the portal perfusion within the nodule. Of 17 e-HCC nodules 5 were hypervascular, 5 were isovascular, 4 were hypovascular, and 3 were vascular spot in hypovascular pattern in contrast to 49 ad-HCC nodules, 43 of which were hypervascular and 6 were isovascular. Of 14 e-HCCs, 9 nodules showed perfusion ...
Transplantation procedures using intraparenchymal injection of stem cells result in tissue injury in addition to associated surgical risks. Intravenous injection of mesenchymal stem cells gives engraftment to lesions, but the method has low efficiency and specificity. In traumatic brain injuries (TBI), there is a transient breakdown of the blood-brain barrier and an inflammatory response, which increase migration of cells from blood to parenchyma. The aim of this investigation was to analyze the effect of intra-arterial administration on cellular engraftment. Experimental TBI was produced in a rat model. Endovascular technique was used to administer human mesenchymal stem cells in the ipsilateral internal carotid artery. Evaluation of engraftment and side effects were performed by immunohistochemical analysis of the brain and several other organs. The results were compared to intravenous administration of stem cells. ...
Objective: To explore the interventional treatment for biliary re-stenosis after metallic stents placement in patients due to cholangiocarcinoma and evaluate its therapeutic effect. Methods: Percutaneous metallic stents placement or combined with continuously infusion arterial chemotherapeutic and chemotherapeutic embolization were performed in 12 patients with biliary re-stenosis using 12 metallic stents. Results: Once stent placement was 100% successful in all 12 cases, TBIL, ALT, GTP and AKP values 7 days postoperatively were significantly lower than that in preoperation. Jaundice was reduced satisfactorily in 12 patients. 3 patients were undergone continuously arterial chemotherapeutics infusion and chemotherapeutic embolization 4 weeks after stents placement. Conclusions: Percutaneous replacement of biliary metallic stents was effective and safe for palliation of malignant biliary re-stenosis and would be much better when combined with ...
The outcome was retrospectively examined and prognostic factors were discussed for arterial chemo-infusion therapy (ACT) through an implanted reservoir system and radiation therapy (RT) in patients with unresectable intrahepatic cholangiocarcinoma (CCC). ACT plus RT were conducted to 25 patients (mean age 61.7 y, M/F 12/13, stage III-IVB) during 10 years from 1996 to 2005 with various regimens of cisplatin (CDDP), 5- fluorouracil (FU), epirubicin (FARM), mitomycin C (MMC) plus 39-50 Gy of radiation in a fractionated manner partly involving internal RT (2 cases, 15 Gy) and RT for metastatic bone (1, 25 Gy). The survival rates at 1, 2 and 3 years after ACT+RT were respectively 52.5, 43.7 and 28.1%; total efficacy (PR) was 36% (9/25) at 6 months; and significantly good prognostic factors were found to be female and absence of metastasis remote and/or lymphatic around artery. Authors concluded that ACT+RT was a meaningful treatment for highly ...
ObjectivesThe SPIRIT V (A Clinical Evaluation of the XIENCE V Everolimus-Eluting Coronary Stent System in the Treatment of Patients With De Novo Coronary Artery Lesions) study is a post-market surveillance experience of the XIENCE V (Abbott Vascular, Santa Clara, California) everolimus-eluting stent (EES) in patients with higher-risk coronary anatomy. BackgroundPrevious pre-approval studies have shown the safety and efficacy of EES in highly selected groups of patients. MethodsThe SPIRIT V trial is a prospective, open label, single arm, multicenter study. Two thousand seven hundred patients with multiple de novo coronary artery lesions suitable for treatment with a planned maximum of 4 EES were enrolled at 93 centers in Europe, Asia Pacific, Canada, and South Africa. Lesions had a referenc...
Wharton's jelly contains large amounts of hyaluronic acid, and glucosamine is an important constituent of this macromolecule. In order to evaluate the placental vascular effects of this aminosugar, small chorionic and stem villous arteries were dissected from placental specimens obtained at normal term vaginal deliveries (n = 15). Ring preparations were mounted in organ baths, and isometric wall tensions were measured. Glucosamine and its epimer galactosamine (5 X 10(-4) to 10(-2) M) produced marked relaxation of contractions induced by PGF2 alpha (10(-5) M) in both chorionic and stem villous arteries. The effect was unchanged after pretreatment with atropin, propranolol and indomethacin. The relaxant effect of the neutral sugar mannose was less pronounced compared with that of the hexosamines. Total tissue concentrations of placental hexosamines have been reported within the range needed to produce placental vascular relaxation in the present ...
Infrainguinal peripheral occlusive disease is increasingly being treated by endovascular techniques. Bare metal stainless steel, self-expanding nitinol stents, drug-eluting and covered stents (stent grafts) are becoming increasingly more important adjuncts to percutaneous translumninal angioplasty in the treatment of peripheral artery disease. In this article the available evidence supporting the use of stents in the femoropopliteal and tibial arteries will be described as well as their limitations. Future stent developments will also be discussed. (orig.) [German] Die endovaskulaere Therapie spielt bei der Therapie der peripheren arteriellen Verschlusskrankheit (PAVK) eine wichtige Rolle. Unbeschichtete ballonexpandierbare Stahlstents, selbstexpandierende Nitinolstents sowie medikamentenbeschichtete und ''covered stents'' (Stentgrafts) haben eine zunehmende Bedeutung als Zusatztherapie zusammen mit der ...
Quantitative hepatic scintiangiography was previously used for evaluating the relative contribution of hepatic arterial and portal venous blood flows to the hepatic circulation. The present study compares 3 different procedures (automatic and manual integration, and slope fitting methods) for analyzing the hepatic time activity curves obtained after bolus i.v. injection of 370 MBq /sup 99m/Tc-diethylentriaminopentacetic acid. Twenty five subjects were studied: Five controls, ten cirrhotics, and ten portal hypertensive patients previously submitted to side to side portacaval anastomosis. The correspondence between results given by the different methods was satisfactory only in shunted patients, and the reproducibility of computed parameters was quite poor for all procedures. Accordingly, none of the methods can be considered as supporting reliable quantitative pathophysiological evaluations. However, the hepatic arterial/portal venous flow ratio ...
A beta microprobe was successfully applied to monitor arterial input function for quantification of regional cerebral blood flow (rCBF) in the monkey brain with {sup 15}O-water and positron emission tomography (PET). The sensitivity of the probe was approximately 0.83 to 1.67 cps/kBq/ml depending on the studies. A preliminary study was performed to find a suitable use and to evaluate the performance of the system and data analysis procedure. The results showed that dispersion correction of measured input function was unnecessary if microprobes were connected directly to the arterial catheter. Then multiple CBF measurements were done in three monkeys under anesthesia. Identical regions of interest were placed with the aid of magnetic resonance imaging (MRI) of each monkey and rCBF values were estimated. Estimated rCBFs were reproducible for several measurements. The mean CBF value for a pentobarbital anesthetized monkey was 46.0 ml/min/100 g ...
The actual mechanisms that maintain the individual disparities in home computer use and internet access that are collectively termed “the digital divide” remain unclear. We hypothesized...Full Text Available
The new collaborative exploitation of the JET Facilities requires suitable technical tools and infrastructure measures to enable the Remote Participation of scientists from all European Fusion labs. Such measures are being gradually introduced. They comprise of a toolkit for Remote Data Access, Remote Computer Access and for teleconferencing, and of infrastructure measures that address network connectivity, network security, shared documentation and technical support.
Assisted users with expired passwords Closed 233 NCICB Support Wizard Accounts Tickets Set up Resource Accounts for individual developers to control and track access on QA Application servers Maintained daily account synchronization between GForge project developers and CVS write access accounts Created FTP and SFTP user accounts for TCGA test, analysis datasets downloads and analysis datasets management.
A nozzle plug for blocking a nozzle in a nuclear steam generator is improved by the addition of hinges which allow the nozzle plug to be inserted into the steam generator through an access port of substantially smaller diameter than the nozzle. A recess is provided in one of the semi-circular plates allowing the plates to nest, further reducing the necessary size of the access port.
Background:Timely access to publicly funded health services is a priority issue across the healthcare continuum in Canada. The purpose of this study was to examine wait list management...Full Text Available
Metadata can be used to support accessibility in connection with improved discovery. ...certain metadata elements provide information about what capabilities are needed--either perceptual-motor, cognitive, socio-economic or geographic--to make use of a resource. This cam improve the ability of users who are disadvantaged in these ways to find resources that meet their needs--and avoid ones [resources] that do not.
Hereditary hemorrhagic telangiectasia (Osler-Rendu-Weber disease) is a genetic disorder with autosomal dominance, variable penetrance, and an estimated prevalence of 1/10,000 inhabitants in France. Diagnosis is based on clinical criteria including epistaxis, telangiectasia, visceral manifestations, and familial occurrence. Pulmonary arteriovenous malformations, present in 15-33% of patients, are its primary visceral complications. The disease may be revealed by infectious and ischemic neurological manifestations due to paradoxical embolism. The high frequency of neurologic complications even in asymptomatic patients justifies systematic screening for pulmonary arteriovenous malformations. Treatment of these malformations is based on percutaneous transcatheter coil embolization of the feeding artery. Pulmonary arterial hypertension is rare in this disease. It may be due to systemic arteriovenous shunting in the liver, which increases cardiac ...
Purpose To study the activation and expression of vascular (aorta and small mesenteric arteries) potassium channels during septic shock with or without modulation of the NO pathway. Methods Septic shock was induced in rats by peritonitis. Selective inhibitors of vascular KATP (PNU-37883A) or BKCa [iberiotoxin (IbTX)] channels were used to demonstrate their involvement in vascular hyporeactivity. Vascular response to phenylephrine was measured on aorta and small mesenteric arteries mounted on a wire myograph. Vascular expression of potassium channels was studied by PCR and Western blot, in the presence or absence of 1400W, an inducible NO synthase (iNOS) inhibitor. Aortic activation of the transcriptional factor nuclear factor-kappaB (NF-?B) was assessed by electrophoretic mobility shift as...
Summary Objective- Gamma-glutamyltransferase (GGT) has been reported to be useful in predicting cardiovascular disease. Arterial stiffness measured by brachial-ankle pulse wave velocity (baPWV) is not only a marker of vascular damage but a significant predictor of cardiovascular events. Gender difference has been reported in the association between GGT and baPWV. We assessed, therefore, the association between GGT and baPWV in a large population and determined whether there was gender difference. Design- This cross-sectional study was conducted at the Asan Medical Centre, Seoul, Republic of Korea. Subjects and measurements- Serum GGT, baPWV and conventional risk factors were measured in 10 988 apparently healthy subjects (7248 men, 3740 women) who participated in a routine health screening...
Opinion statement Because a minority of patients with D-transposition of the great arteries are diagnosed in utero by ultrasound, most present after delivery with cyanosis. In the absence of apparent lung disease, cyanotic neonates suspected of having a cardiac lesion should be immediately transferred to an intensive care unit at a pediatric tertiary care center for monitoring, resuscitation, and to define the cardiac anatomy and physiology. A prostaglandin E-1 infusion is usually initiated to maintain ductal patency and promote intra-cardiac mixing. In the past, balloon atrial septostomy (BAS) was routinely performed to enlarge the atrial septal defect and improve intra-cardiac mixing while the infants awaited surgery. Recent literature has reported an increase risk of stroke in neonates ...
To evaluate the effectiveness of percutaneous mechanical declotting. Using a 7-F Desilets-Hoffman sheath and the crossed-catheter technique, we aspirated the intragraft clot and pushed the residual clot into the central circulation with balloon catheters. The success rate, procedure time, complications and patency rates were evaluated. Technical success was achieved in 24 of 32 cases, with a procedure time of 30-240 (average, 111) minutes. In five of eight cases in which technical failure occurred, the guide wire failed to reach the stenotic site and in the other three, there was insufficient luminal dilatation. Complications included vein ruptures (n=2), arterial emboli (n=1) and arterial dissection (1), but there was no evidence of clinical symptoms of pulmonary embolism. The six-month patency rate was 67.8%. Mechanical declotting of thrombosed dialysis graft using a balloon catheter is relatively inexpensive, safe and fast, and is well ...
Propanolol is a betablocker drug used in the treatment of arterial hypertension related diseases. In order to achieve an optimal performance of this drug it is important to consider the possible interactions of propanolol with plasma proteins. In this work, we have used several experimental techniques to characterise the effect of addition of the betablocker propanolol on the properties of bovine plasma fibrinogen (FB). Differential scanning calorimeter (DSC), circular dichroism (CD), dynamic light scattering (DLS), surface tension techniques and atomic force microscopy (AFM) measurements have been combined to carry out a detailed physicochemical and surface characterization of the mixed system. As a result, DSC measurements show that propranolol can play two opposite roles, either acting ...
A chicken model was prepared that provides a simple and economical method of evaluating the use of fibrin-specific monoclonal antibody 64C5 in the detection of peripheral vascular thrombi. Human fibrin was clotted in segments of a chicken's femoral artery and vein prior to intravenous injection of radioiodinated antibody 64C5. After a 3-hr perfusion time, the thrombosed and contralateral control segments of the vessels were excised and counted for radioactivity. The radiolabeled 64C5 uptake ratio of the thrombosed segment to the control segment was 5.4 +/- 1.2 (p less than 0.007) in the femoral artery, and 3.8 +/- 1.1 (p less than 0.02) in the femoral vein. This in vivo chicken model may also find application in studies of targeting agents for human fibrin.
Abstract During extracorporeal life support (ECLS), a large portion of the hemodynamic energy is lost to various components of the circuit. Minimization of this loss in the circuit leads to better vital organ perfusion and decreases the risk of systemic inflammation. In this study, we evaluated the hemodynamic properties of differing lengths of tubing in a simulated neonatal ECLS circuit. The neonatal ECLS circuit used in this study included a Capiox Baby RX05 oxygenator (Terumo Corporation, Tokyo, Japan), a Rotaflow centrifugal pump (MAQUET Cardiopulmonary AG, Hirrlingen, Germany), and a heater and cooler unit. An 8 Fr Biomedicus arterial and a 10 Fr Biomedicus venous cannula were connected to the pseudopatient. One fourth inch tubing was used for both the arterial and the venous line. A ...
Abstract Gaseous microemboli (GME) remain a challenge for cardiopulmonary bypass (CPB) because there is a positive correlation between microemboli exposure during CPB and postoperative neurological injury. Thus, minimizing the number of GME delivered to pediatric patients undergoing CPB procedures would lead to better clinical outcomes. In this study, we used a simulated CPB model to evaluate the effectiveness of capturing GME and the degree of membrane pressure drop for a new membrane oxygenator, Capiox Baby FX05 (Terumo Corporation, Tokyo, Japan), which has an integrated arterial filter with open and closed purge line. We used identical components in this study as our clinical CPB circuit. Three emboli detection and classification quantifier transducers were placed at prepump, preoxygena...
Aims.- To examine the relationships between depression, coronary artery disease, type 2 diabetes, metabolic syndrome and quality of life in Taiwanese adults from a cardiovascular department of a major hospital in Taiwan. Background.- Research suggests associations between depression, metabolic syndrome and quality of life. Despite this fact, few studies have investigated these relationships among Taiwanese. Design.- A cross-sectional descriptive correlational design was used to conduct this study. Methods.- A convenience sample of 140 adults participated in the study. Data were analysed with descriptive statistics, Pearson-s correlations, hierarchical regression and t-tests. Results.- Almost a half of the subjects (465%) had metabolic syndrome. The most common combination of metabolic synd...
Atrial fibrillation (AF) is common after coronary artery bypass grafting (CABG) and increases the morbidity and cost. Amiodarone reduces AF after CABG. Ranolazine, an antianginal agent, also prolongs atrial refractoriness and inhibits after depolarizations and triggered activity; effects that could decrease AF after CABG. The present study compared amiodarone versus ranolazine for the prevention of AF after CABG. A retrospective cohort study of patients undergoing CABG at Aspirus Hospital from June 2008 to April 2010. The patients received either amiodarone (400 mg preoperatively followed by 200 mg twice daily for 10 to 14 days) or ranolazine (1,500 mg preoperatively followed by 1,000 mg twice daily for 10 to 14 days). The primary end point was any identified AF after CABG. A total of 393 ...
Intra-arterial subtraction angiography(IADSA) using Fuji computed radiography(FCR) was performed on 130 patients with cervical, pelvic, peripheral and abdominal diseases. It was compared with conventional angiography(radiographs produced by combining photographic film with an intensifying screen) performed on same patients. Radiographs produced by FCR were better than conventional radiographs in cervical, pelvic and peripheral angiography. In the abdominal angiography using FCR, there was misregistration artifact in some cases, but in hepatic angiography, the new radiographs under the injection of small amount of contrast medium(about 10ml) and the short exposure duration(about 10 seconds) were excellent. It was as valuable as conventional angiography (infusion hepatic angiography) for diagnosing hepatic neoplasms. (author).
MRT is able to demonstrate arteries while MR angiography can quantify blood flow by a non-invasive method. In the present paper blood flow measurements were carried out in four selected cases on the basis of phase mapping. In 3 patients with lesions in the pelvis or thigh, angiography was performed in order to localise the stenosis or occlusion and this was followed by qantitative blood flow measurements. The results showed that angiography may not always provide all necessary information concerning a haemodynamically significant stenosis. The method may also be used for quantifying blood flow in the renal arteries and that it has significant advantages over the colour Doppler method. (orig.).
This article describes a flexible and extensible infrastructure for applying Web-Technologies to embedded systems.The presented approach develops a Three-level-Architecture consisting of the embedded system, the universal Remote-Access-Server and the Remote-Access-Client. A system-spanning general interface allows the binding of embedded systems in order to access their process data. Additionally, this procedure facilitates a flexible processing of the device data, so that it is ready to be used by different control devices. To ensure flexibility - connecting different devices on the one side and providing information for different clients like PC, PDA or mobile phone on the other side - a new XML-based description language (Service Description Markup Language - SDML) is introduced. The SDML documents contain information about connected embedded systems, reusable device data and the presentation policies for different ...
We study the spin dependence of accretion onto rotating Kerr black holes using analytic techniques. In its linear regime, angular momentum transport in MHD turbulent accretion flow involves the generation of radial magnetic field connecting plasma in a differentially rotating flow. We take a first principles approach, highlighting the constraint that limits the generation and amplification of radial magnetic fields, stemming from the transfer of energy from mechanical to magnetic form. Because the energy transferred in magnetic form is ultimately constrained by gravitational potential energy or Killing energy, the spin dependence of the latter allows us to derive spin-dependent constraints on the success of the accreting plasma to expel its angular momentum. We find an inverse relationship between this ability and black hole spin. If this radial magnetic field generation forms the basis for angular momentum transfer in ...
We present high-precision time-series photometry of the classical delta Scuti star HD 144277 obtained with the MOST (Microvariability and Oscillations of STars) satellite in two consecutive years. The observed regular frequency patterns are investigated asteroseismologically. HD 144277 is a hot A-type star that is located on the blue border of the classical instability strip. While we mostly observe low radial order modes in classical delta Scuti stars, HD 144277 presents a different case. Its high observed frequencies, i.e., between 59.9c/d (693.9 microHz) and 71.1c/d (822.8microHz), suggest higher radial orders. We examine the progression of the regular frequency spacings from the low radial order to the asymptotic frequency region. Frequency analysis was performed using Period04 and SigSpec. The results from the MOST observing runs in 2009 and 2010 were compared to each other. The resulting frequencies were submitted to ...
The visual outcomes of Acanthamoeba keratitis, a rare cause of corneal infection, can be devastating. This paper reports two contact lens wearers with severe pain and photophobia who presented to the emergency room. Biomicroscopy revealed radial keratoneuritis in both individuals. Tissue culture on a nonnutrient agar plate with Escherichia coli overlay resulted in a heavy growth of Acanthamoeba. The inpatient treatment included 0.02% polyhexamethylene biguanide, chlorhexidine, neomycin/polymyxin B/bacitracin (Neosporin), and oral fluconazole, which successfully controlled the corneal infection and improvement in the best corrected visual acuity in both patients. Infection did not recur during the 12-month follow-up period. Acanthamoeba keratitis can present as radial keratoneuritis, mimicking other common corneal infections resulting in diagnostic and treatment delays. Early diagnosis and prudent treatment of Acanthamoeba keratitis are the keys ...
We present analytic and numerical results which illustrate the effects of Jupiter's accretion of nebular gas and the planet's radial migration on its Trojan companions. Initially, we approximate the system by the planar circular restricted three-body problem and assume small Trojan libration amplitudes. Employing an adiabatic invariant calculation, we show that Jupiter's thirty-fold growth from a $10 M_\\oplus$ core to its present mass causes the libration amplitudes of Trojan asteroids to shrink by a factor of about 2.5 to $\\sim 40%$ of their original size. The calculation also shows that Jupiter's radial migration has comparatively little effect on the Trojans; inward migration from 6.2 to 5.2 AU causes an increase in Trojan libration amplitudes of $\\sim4%$. In each case, the area enclosed by small tadpole orbits, if made dimensionless by using Jupiter's semimajor axis, is approximately conserved. Similar adiabatic invariant calculations ...
In the frame of the European Technology R and D programme for International thermonuclear experimental reactor (ITER) and in the area of high heat flux plasma facing components (HHFC), representative small-scale mock-ups were manufactured and tested to compare different concepts and joining technologies (i.e. active brazing, hot isostatic pressing (HIPping), diffusion bonding, etc.). On the basis of the results obtained by thermal fatigue tests, the monoblock concept resulted to be the most robust one, particularly when the HIPping manufacturing technology is used. Within this programme, ENEA developed an alternative technique for manufacturing plasma-facing components with a monoblock geometry of the ITER machine. The basic idea of this technique, named hot radial pressing (HRP), is to perform a radial diffusion bonding between the cooling tube and the armour tile by pressurising the internal tube only and by keeping the process parameters ...
The thermal contact resistance between balls and inner and outer rings of thermally steady space-use deep groove ball bearings was studied experimentally to verify the validity of the previously proposed calculation method for the resistance. The 440C stainless steel single row bearing was used for measuring its steady state temperature distributions in a vacuum environment under axial, radial and combined load conditions. As a result, the experimental results of the resistance well agreed with calculated ones under each load condition resulting in the sufficient validity at nearly the same surface roughness. It was necessary to apply a static equivalent radial load to calculation under the combined load that a contact angle is larger than the angle of resultant force dependent on both load components. In experiments under only radial load, measurement of outer ring temperatures was necessary at some points with no contact ...
In this work, the Calibration-Free approach for Laser-Induced Breakdown Spectroscopy (CF-LIBS) was applied for the first time to radially resolved spectra emitted by a laser-induced plasma. The radial profiles of plasma temperature and electron number density were used to calculate the local relative concentration of the elements of interest. We analyzed a set of profiles of the local spectral emission coefficient obtained previously by means of spatial deconvolution of the spectra from a copper-based alloy (Cu 93, Fe 5, Mn 1, Ni 1 wt.%) laser-induced plasma. A spatially integrated spectrum of the same plasma was also analyzed for comparison purpose. The relative abundance of the minor components Fe, Mn and Ni was calculated. The results obtained from the central region of the plasma were closer to the nominal concentrations than those obtained from the spatially integrated spectrum. However, an increasing deviation was observed towards the ...
In this work, the Calibration-Free approach for Laser-Induced Breakdown Spectroscopy (CF-LIBS) was applied for the first time to radially resolved spectra emitted by a laser-induced plasma. The radial profiles of plasma temperature and electron number density were used to calculate the local relative concentration of the elements of interest. We analyzed a set of profiles of the local spectral emission coefficient obtained previously by means of spatial deconvolution of the spectra from a copper-based alloy (Cu 93, Fe 5, Mn 1, Ni 1 wt.%) laser-induced plasma. A spatially integrated spectrum of the same plasma was also analyzed for comparison purpose. The relative abundance of the minor components Fe, Mn and Ni was calculated. The results obtained from the central region of the plasma were closer to the nominal concentrations than those obtained from the spatially integrated spectrum. However, an increasing deviation was observed towards the ...
We present ultraviolet through far-infrared (FIR) surface brightness profiles for the 75 galaxies in the Spitzer Infrared Nearby Galaxies Survey (SINGS). The imagery used to measure the profiles includes Galaxy Evolution Explorer UV data, optical images from Kitt Peak National Observatory, Cerro Tololo Inter-American Observatory, and Sloan Digital Sky Survey, near-IR data from Two Micron All Sky Survey, and mid- and FIR images from Spitzer. Along with the radial profiles, we also provide multi-wavelength asymptotic magnitudes and several nonparametric indicators of galaxy morphology: the concentration index (C 42), the asymmetry (A), the Gini coefficient (G), and the normalized second-order moment of the brightest 20% of the galaxy's flux (M-bar20). In this paper, the first of a series, we describe the technical aspects regarding the surface photometry, and present a basic analysis of the global and structural properties of the SINGS galaxies at different ...
Abstract In this paper, the effect of several turbulence parameters during various flow conditions in Owens Valley, educed from coherent Doppler lidar data have been studied. Radial velocity structure functions are processed to estimate the turbulent kinetic energy (TKE) dissipation rate, integral length scale and velocity variance, assuming a theoretical model for isotropic wind fields. Corrections for turbulence measurements have been considered to address the complications due to inherent volumetric averaging of radial velocity over each range gate, noise of the lidar data, and the assumptions required to estimate effects of smaller scales of motion on turbulence quantities. Using data from the Terrain-induced Rotor Experiment (T-REX) in April-May 2006, vertical profiles of wind and tur...
Determining the radial distribution of the thermal neutron field in the core of the Dalat reactor was done by the Cu foil activation method. The measured data were fitted by the least square method to determine some physical parameters of the reactor, as follows: 1. Laplacian: B_r"2 = (84.6 +- 5.5)10_-_4/,cm"2. 2. The effective radius: R_e_f_f = (27.6 +- 1.0)cm. 3. The extrapolation distance: #lambda#_r = (8.7 +- 1.0)cm. 4. The unequal coefficient of the effective multiplication: k_r = 1.77 +- 0.11. (author). 3 refs., 4 figs., 1 tab.
A rotary drill bit having a drill bit body and at least one trunnion projecting from the drill bit body and a rotary cutter supported on at least one radial roller bearing on the trunnion. The rolling elements of the bearing are guided on at least one axial end facing the drill bit body in an outer bearing race groove incorporated in the bore of the rotary cutter. The inner bearing race groove is formed on the trunnion for the rolling elements of the radial roller bearing. At least one filling opening is provided which extends through the drill bit body and trunnion and is essentially axially oriented having one terminal end adjacent the inner bearing race groove and at least one filler piece for sealing the opening.
The noncrystalline compounds MoS_3, WS_3 and MoSe_3 were studied by X-ray diffraction. From the diffuse intensities radial distribution functions were computed and interpreted in terms of pair distribution functions. The substances are built up by microcrystallites which contain three metal atoms and are bridged statistically to each another. The shortest metal chalcogen distances d(MoS) approximately d(WS) = 2.40 +- 0.05 A and d(MoSe) = 2.50 +- 0.05 A are significantly longer than in MS- or MSe compounds with a d"0 configuration of the metal respectively and metal-metal distances within the microcrystallites are less than 3 A. (author).
A generalized relativistic harmonic oscillator for spin 1/2 particles is studied. The Dirac Hamiltonian contains a scalar, $S$, and a vector, $V$, quadratic potentials in the radial coordinate, as well as a tensor potential, $U$, linear in $r$. Setting either or both combinations $\\Sigma=S+V$ and $% \\Delta=V-S$ to zero, analytical solutions for bound states of the corresponding Dirac equations are found. The eigenenergies and wave functions are presented and particular cases are discussed, devoting a special attention to the non-relativistic limit and the case $\\Sigma=0$, for which pseudospin symmetry is exact. We also show that the case $U=\\Delta=0$ is the most natural generalization of the non-relativistic harmonic oscillator. The radial node structure of the Dirac spinor is studied for several combinations of harmonic oscillator potentials, and that study allows us to explain why nuclear intruder levels cannot be described in the ...
The authors describe a new method which makes it possible to determine the radial distribution of the diffuse component of galactic gamma rays outside the solar circle. They use the observation that a good correlation exists between gamma-ray intensities and total column densities of the local interstellar gas and that the fractional column density of H_2<0.1 HI outside the solar circle. Thus the gamma-ray intensities are shown to be proportional to N(HI). The authors use the kinematics of the HI to determine the distances from which various fractions of the emission originate in the second and third galactic quadrants. Preliminary results of our analysis show that a significant flux of gamma rays originates from distances as large as 18 kpc from the galactic centre. (Auth.).
The confining effect of a spherical substrate inducing anchoring (normal to the surface) of rod-like liquid crystal molecules contained in a thin film spread over it has been investigated with regard to possible changes in the nature of the isotropic-to-nematic phase transition as the sample is cooled. The focus of these Monte Carlo simulations is to study the competing effects of the homeotropic anchoring due to the surface inducing orientational ordering in the radial direction and the inherent uniaxial order promoted by the intermolecular interactions. By adopting entropic sampling procedure, we could investigate this transition with a high temperature precision, and we studied the effect of the surface anchoring strength on the phase diagram for a specifically chosen geometry. We find that there is a threshold anchoring strength of the surface below which uniaxial nematic phase results, and above which the isotropic fluid cools to a ...
More data about TACE and pTACE seem necessary to better define the global treatment strategy for HCC. Aim of our analysis was to evaluate the role of TACE, either with lipiodol (traditional) or drug-eluting...Full Text Available
Purpose: Three-dimensional rotational angiography (3DRA) is a new technique based on a rotational angiographic acquisition able to display arterial vessels in a 3D rendering mode. The system was mainly developed for neuroradiological evaluations but preliminary extracranial experiences have also been reported. The aim of our work was to compare the results of three-dimensional angiography of the carotid arteries done with high-flow injection of contrast medium from the aortic arch with the results of selective angiography. Materials and methods: Twenty patients underwent digital angiography of the supra-aortic vessels in order to quantify a stenosis of the carotid bifurcations previously detected at Doppler Ultrasound. Examinations were performed with the Philips Integris Allura system provided with the rotational angiography (RA) tool connected to a workstation for three-dimensional reconstruction able to display vessels in a 3D fashion ...
1. The effects on micturition of RP 67,580, a selective NK1 receptor antagonist, and SR 48,968, a highly, potent antagonist at NK2 receptor sites, given intrathecally (i.t.) or intra-arterially (i.a.)...Full Text Available
Accumulation of "8"5Kr in arterial blood of sheep occurs within 10 min of inhalation exposure initiation, and disappears by 30 min after exposure termination. As reported for other species, "8"5Kr concentrations in fat were approximately 10 times those in other tissues.
PPARgamma agonists have been proposed to exert more than metabolic benefits, particularly by anti-inflammatory mechanisms. We hypothesized that pioglitazone might modulate inflammatory and vascular responses to lipopolysaccharide (LPS). In a placebo-controlled parallel-group study in 18 healthy male subjects, the E. coli endotoxin model of inflammation (20 IU/kg i. v.) was employed to test the effect of 60 mg pioglitazone over nine days on inflammatory cytokines. Macrovascular function and microvascular blood flow were assessed by brachial artery ultrasound and retinal blood flow parameters, respectively. Pioglitazone increased brachial artery diameter by 5.6% but had no effect on other outcome parameters under resting conditions. LPS increased cytokine levels to peak concentrations of 91.3+/-22.5 ng/ml (IL-6), 261.4+/-60.0 ng/ml (TNFalpha), and 524.5+/-15.3 ng/ml (VCAM-1). The endotoxin caused microvascular vasodilation and increased retinal ...
Patient monitoring during mechanotherapy based on electrocutaneous impedance measurement is discussed. Methods implemented by the Alpharhythmica computer-assisted system are described. Mechanotherapy modifies electrocutaneous impedance as compared to other parameters: heart rate, arterial pressure, and body temperature. Real time criteria of mechanotherapy efficacy based on electrocutaneous impedance measurement are suggested. Results of electrocutaneous impedance monitoring are presented.
1. In order to determine the long-term influence of neonatal hypoxia on catecholaminergic activity in peripheral arterial chemoreceptors and brainstem noradrenergic cell groups (A1, A2, A5 and A6),...Full Text Available
The aim of this study was to evaluate imaging features of different coronary artery stents during multislice CT Angiography (MSCTA). Nineteen stents made of varying material (steel, nitinol, tantalum) and of varying stent design were implanted in plastic tubes with an inner diameter of 3 mm to simulate a coronary artery. The tubes were filled with iodinated contrast material diluted to 200 Hounsfield units (HU), closed at both ends and positioned in a plastic container filled with oil (-70 HU). The MSCT scans were obtained perpendicular to the stent axes (detector collimation 4 x 1 mm, table feed 2 mm/rotation, 300 mAs, 120 kV). Axial images and multiplanar reformations were evaluated regarding artifact size, lumen visibility, and intraluminal attenuation values. Artifacts characterized by artifactual thickening of the stent struts leading to apparent reduction in the lumen diameter and increased intraluminal attenuation values were observed in ...
BACKGROUNDSeveral carotid endarterectomy (CEA) randomized controlled trials (RCTs) and series have reported higher perioperative stroke and death rates for women...Full Text Available
Infections of aortoarterial prostheses are serious, difficult to detect, and difficult to treat. Scintigraphy with indium-111 labeled autologous leukocytes is an accurate noninvasive method of assessing the presence and extent of such an infection. In three cases of aorto-arterial bypass graft infections, the leukocyte study was successful in establishing the diagnosis and in assessing the extent of infection. Other noninvasive diagnostic techniques are useful, but all have serious limitations. The leukocyte study alone appears to be free of likely sources of error.
The corrected transposition of the great arteries is an usual congenital cardiac malformation, which consists of transposition of great arteries and ventricular inversion, and which is caused by abnormal development of conotruncus and ventricular looping. High frequency of associated cardiac malformations makes it difficult to get accurate morphologic diagnosis. A total of 18 cases of corrected transposition of the great arteries is presented, in which cardiac catheterization and angiocardiography were done at the Department of Radiology, Seoul National University Hospital between September 1976 and June 1981. The clinical, radiographic, and operative findings with the emphasis on the angiocardiographic findings were analyzed. The results are as follows: 1. Among 18 cases, 13 cases have normal cardiac position, 2 cases have dextrocardia with situs solitus, 2 cases have dextrocardia with situs inversus and 1 case has ...
Hepatocellular carcinoma (HCC) is characterized by tumor vascularization from the hepatic artery. The objective of our work was to compare color Doppler ultrasonography (CDU), including power Doppler ultrasonography (PDU) with radiographic imagings with contrast medium in regard to the detection of the arterial tumor vascularity of small hepatocellular carcinomas (HCC). We examined 42 small HCC lesions 2 cm or less in diameter in 37 patients for arterial tumor vascularity by conventional CDU, PDU, dynamic computed tomography (dCT), digital subtraction angiography (DSA), and CT hepatic arteriography (CTA). Color images were detected in 25 (59.5%) and 28 (66.7%) of the 42 lesions with conventional CDU and PDU, respectively, and tumor vascularity was detected in 26 (61.9%) by dCT, 23 (54.8%) by DSA, and 29 (69.0%) by CTA. Tumor vascularity could be detected in 51.9% by PDU and CTA, more than by conventional CDU, dCT, and DSA ...
In the isolated rat mesenteric bed, the 1 min perfusion with 100 nm anandamide, a concentration that did not evoke vasorelaxation, elicited an acute release of 165.1 ± 9.2 pmol nitric...Full Text Available
BACKGROUND:Despite an increasing body of evidence on the benefit of lowering elevated levels of low-density lipoprotein cholesterol (LDL-C), there is still considerable concern that...Full Text Available
BackgroundPaclitaxel-eluting stents decrease angiographic and clinical restenosis following percutaneous coronary intervention compared to bare metal stents. TAXUS Element is a third-generation...Full Text Available
1. The acute haemodynamic effects of intravenous nisoldipine (1, 2, 4 microg kg(-1)) and nifedipine (2.5, 5, 10 microg kg(-1)) were compared in a randomised, within-patient crossover study. Fifteen...Full Text Available
Hemorrhagic cystitis is a disorder which causes bleeding from diffusely inflammatory bladder mucosa. Here we present a case of severe hemorrhagic cystitis caused by melphalan. A 70-year-old man with...Full Text Available
Objectives This paper examines the determinants of the insureds decision to use their health insurance card when seeking outpatient and inpatient health care in Vietnam. Methods Uses Vietnams latest Household Living Standard Survey data and random-intercept logistic regression to assess the influence of the observed individual, household and commune/ward factors on the insureds decision to access health insurance benefits while controlling for the unobserved commune/ward-specific factors. Results Compared to the compulsory enrollees, the voluntary enrollees and the beneficiaries of the Health Care Fund for the Poor are less likely to use their card when seeking inpatient care. An individuals likelihood of accessing insurance benefits varies inversely with income and the level of education,...
The spectre of exclusionary medical service provision, restricted clinic access and physician targeting in sectarian-divided Iraq underscores the crucial and timely need for qualitative research into the inter-relationship between conflict, identity and health. In response, this paper provides a critical ethnography of obstetric service provision and patient access during Shia-Sunni hostilities in Gilgit Town, capital of Pakistans Northern Areas (2005). I analyse how services were embedded in and constrained by sectarian affiliation in ways that detrimentally impacted Sunni women patients and hospital staff, resulting in profoundly diminished clinic access, reduced physician coverage and a higher observed incidence of maternal morbidity and mortality. The paper first situates obstetric med...
Purpose - This paper aims to discuss the procedures and methods developed at Washington State University to digitize and make accessible historic moving images. Design/methodology/approach - The paper describes the selection and the use of low-cost technologies to transfer analog film to digital formats. Issues related to the conversion, description, and online hosting of digital films are also addressed. Findings - Though the steps involved in digitizing film are not trivial, the benefits of access both for the public and archives staff outweigh the expense and labor involved. The procedures described in this paper involve low upfront costs and are sustained through cost recovery fees. Research limitations/implications - The focus of this paper is on managing, describing, and providing on...
In both office and home environments, Ethernet represents the dominant networking technology in use. Ethernet is low cost and the networks are fairly understood by users. The author began by explaining the physical and data link layers of Ethernet, then touched on fibre-optic cables. The industrial protocols were discussed, followed by Ethernet network topology. The environmental robustness of Ethernet networks was reviewed, with a word of caution from the author, advising to properly evaluate whether Ethernet represents a mission-critical component of the substation, as substation control houses are not environmentally controlled spaces, often minimally heated and no cooling. Engineering access to station Integrated Electric Drives (IEDs). By properly connecting Ethernet networks, it is possible to access relays in the substations from desktop engineering workstations in the central office. Network security issues must be addressed to prevent ...
Purpose - The purpose of this paper is to encourage other libraries to provide access to their own original content via the web. By way of case study, the process of identifying materials, scanning them and creating web access to original content will be explored. Design/methodology/approach - To implement a book digitization project, three major things need to be present. The library must own material that was published prior to 1923, making them safely out of copyright in the USA; the library needs access to server space on the web and the library needs to own scanning equipment. Findings - This project demonstrated that a library does not necessarily need to obtain grant funding to begin an effective and successful digitization program. It also revealed a few things that would improve t...
Objective: To determine the optimal contrast injection protocol for 64-MDCT coronary angiography. Materials and methods: One hundred and fifty consecutive patients scheduled to undergo retrospectively electrocardiographically gated 64-MDCT. Each 30 patients were assigned to use a different contrast protocol: group 1: uniphasic protocol (contrast injection without saline flush); group 2: biphasic protocol (contrast injection with saline flush); group 3A, 3B and 3C: triphasic protocol (contrast media + different saline diluted contrast media + saline flush). Image quality scores and artifacts were compared and evaluated on both transaxial and three-dimensional coronary artery images among each contrast protocol. Results: Among the triphasic protocol groups, group 3A (30%:70% contrast media-saline mixture was used in second phase) used the least contrast media and had the least frequency of streak artifacts, but there were no significant differences in coronary ...
Purpose: To evaluate the success rates of the implantation of stent grafts in the treatment of peripheral aneurysms. Materials and methods: in 13 patients with 15 aneurysms at the common iliac artery (n = 6), external iliac artery (n = 1), hypogastric artery (n = 2), femoral artery (n = 2) or popliteal artery (n = 4), implantation of dacron-covered nitinol stents was performed. The patients were followed up for three to 20 months (mean, 8.8 months) with intravenous digital subtraction angiography, CT or colour-coded Doppler sonography. Results: In all cases, the aneurysm was successfully occluded after stent implantation. In one case with a popliteal aneurysm, kinking of the vessel caused thrombosis of the stent. The stent was successfully reopened. The aneurysm however, had to be surgically treated 9 months later. The primary and secondary patency rates at 6 months were 93% and ...
The wind unit working wheel has 4 radial rectangular frames arranged in two vertical planes which are perpendicular to each other. In the planes limited by the frames, on loop hinges with limiting supports, there are flat blades. When the working wheel rotates under the influence of wind pressure, the blades automatically occupy a vertical or horizontal (wind vane) position depending on the direction of blade motion and the direction of wind velocity.
Transition rates for electrons in the superheavy elements Z = 114, 126, 134, 145, 164 and 173 are calculated. K, L and M-shells are considerd as final states. The 2s - 1s stransition of multipolarity M1 is dominant for Z = 173 with a transition time of 10"-"1"8s. The radial expectation values and #sq root# are given. (orig.).
The completed ribbon-winding theory, including temperature loading of the high-pressure compound vessel, was proposed. The influence of the bending stress in the wound ribbon is taken into account. Internal core of the compound vessel consists of matrix and ring, made of different materials. The relations were derived in analytical form, describing the radial distribution of necessary tangential prestressing.
The general relativistic version is developed for Robertson's discussion of the Poynting-Robertson effect that he based on special relativity and Newtonian gravity for point radiation sources like stars. The general relativistic model uses a test radiation field of photons in outward radial motion with zero angular momentum in the equatorial plane of the exterior Schwarzschild or Kerr spacetime.
In this Letter the bound states of (2+1) Dirac equation with the cylindrically symmetric $\\delta (r-r_{0})$-potential are discussed. It is surprisingly found that the relation between the radial functions at two sides of $r_{0}$ can be established by an SO(2) transformation. We obtain a transcendental equation for calculating the energy of the bound state from the matching condition in the configuration space. The condition for existence of bound states is determined by the Sturm-Liouville theorem.
The motion of a test particle moving in an interior static spherically symmetric geometry is investigated. The author concludes that an oscillatory motion with the test particle changing its motion from a free fall towards the center to an outward radial motion can not exist for any static interior spherically symmetric model.
The Klein-Gordan equation in the background of the Schwarzschild curved space-time is considered and the scattering of radial tardyons and tachyons from a black hole is studied. It is shown that black holes of mass below 7x10/sup 14/g may contain bound states of tardyons of pion mass which will be unstable on account of the presence of an attractive r/sup -4/ term.
The Klein-Gordan equation in the background of the Schwarzschild curved space-time is considered and the scattering of radial tardyons and tachyons from a black hole is studied. It is shown that black holes of mass below 7x10"1"4g may contain bound states of tardyons of pion mass which will be unstable on account of the presence of an attractive r"-"4 term. (author).
''Magnetic braking'' of the plasma toroidal rotation in the high confinement H mode by applied resonant, low m,n=1 static error fields is used in DIII-D [Nucl. Fusion 31, 875 (1991)] as an independent control to evaluate the E_rxB stabilization of microturbulence in the plasma core. In the core (#rho# approx-lt 0.9) of a tokamak, the radial electric field and its shear are dominated by toroidal rotation. The fundamental quantity for shear stabilization of microturbulence is shear in the velocity of the fluctuations v_p_e_r_p_e_n_d_i_c_u_l_a_r#approx#E_rxB/B#centre dot#B which in the core is v_p_e_r_p_e_n_d_i_c_u_l_a_r#approx#v_#phi#B_#theta#/ B_#phi#. With magnetic braking greatly decreasing the toroidal rotation and thus reducing the core radial electric field and shear, far infrared (FIR) measurements of density microturbulence show downshifting in frequency near #rho##approx#0.8 as a result of the reduced Doppler shift ...
Radiation therapy has shown definite technical improvement due to application of proton beam irradiation. Clinical results of proton beam therapy also suggested enlargement of indication ranges in radial treatment and decrease of post radiation damages of the treatment of cancers in deep-seated organs. Inprovement of result in cancer therapy could be expected by this treatment technique in the future.
A general theorem on the GBDT version of the B\\"acklund-Darboux transformation for systems rationally depending on the spectral parameter is treated and its applications to nonlinear equations are given. Explicit solutions of direct and inverse problems for Dirac-type systems, including systems with singularities, and for the system auxiliary to the $N$-wave equation are reviewed. New results on explicit construction of the wave functions for radial Dirac equation are obtained.
Considering the radial motion of a test particle in the Schwarzschild field in the hypothesis of local rotational invariance, the authors discuss the conditions to be satisfied by a physically acceptable model of broken SO(3,1) symmetry, and shown in particular that to preserve causality a breaking, even infinitesimal, makes necessarily impenetrable the interior of the Schwarzschild sphere.
Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computer tomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained
The influence of RTA (Rapid Thermal Anneal) treatment on MOS radiation hardness is demonstrated and compared with classical furnace treatment. In the case of the RTA, the oxide trapped charge is found to depend on: (i) the anneal temperature as expected, data are in good agreement with a recently developed model of oxygen out-diffusion; (ii) the location across the wafer with a radial dependence, results could be related to stress induced by thermal gradient.
Compton scatter tomography utilizes the electronic collimation characteristics available through the Compton scattering angle-energy correlation to obtain tomographic images. In this work we present particular aspects of the technique, which are relevant to the inverse radiation transport problem of reducing marginal projection data to radial two-phase flow regime maps. The results indicate a viable technique for the tomographic imaging of tow-phase flow using practical source strengths and reasonably few detectors.
A unified calculation of neutron-rich isotopes in lithium is performed using the hyperspherical basis in which the underlying symmetry of each isotope exhibits a simple structure. The variation of the binding energy as a function of mass number is qualitatively reproduced, and the asymptotic of radial distribution of each isotope decreases exponentially. The form factors of the lithium isotopes are calculated and display diffraction minima. 27 refs., 3 figs., 3 tabs.
One of the requirements for a federated information system is interoperability, the ability of one computer system to access and use the resources of another system. This feature is particularly...Full Text Available
Presented here is a case of a young woman, with an undiagnosed osteoid osteoma of the spine, which presented with painful scoliosis in adolescence and was treated by bracing until her accession to adulthood....Full Text Available
... Accession Number : ADB119274. Title : Transdermal Drug Delivery System. Stage 1. Volume 1. Descriptive Note : Final rept. 15 Aug 85-14 Oct 87,. ...
... a woman with a history of PID, perhaps endometriosis -- or some limited vaginal access because of the ... I'm doing an oophorectomy or, you know, endometriosis case where we need to use bipolar sealing ...
...of stations and a number of components, and meta information on air quality monitoring networks and stations. Access the database Producer Europe Environment Agency Content ...of stations and a number of components, and meta information on air quality monitoring networks and stations. Coverage National (Europe) Number of records...
IntroductionResearch is an essential tool in facing the challenges of scaling up interventions and improving access to services. As in many other countries, the translation of research...Full Text Available
BackgroundTelephone quit lines are accessible to many smokers and are used to engage motivated smokers to make quit attempts. Smoking cessation counselling provided via telephone...Full Text Available
The mechanisms controlling seed dormancy in Arabidopsis (Arabidopsis thaliana) have been characterized by proteomics using the dormant (D) accession Cvi originating from the Cape Verde...Full Text Available
... Some OA publishers (such as BMC and PLoS) waive the fee for all researchers affiliated with institutions that have purchased an annual membership. A common misunderstanding is that all OA journals use an \\
A Pd(0)-catalyzed intramolecular Heck-type reaction of oxime ether has been developed, providing convenient access to heterocyclic oximes. PMID:21964259
Skip to Main Content Skip to Main Navigation National Highway Traffic Safety Administration Accessible menu--Sitemap Driving Safety Aggressive Driving Bicycles Child Safety...
...links ensure all of our managed accommodation is easily accessible to both campus sites and our special student arrangement makes travelling on the Metro rapid transit system easily affordable. Our halls are comfortable and they are very reasonable. Download the rents table here Rents 2009-2010 Students living in ...
An evaluation of totally implanted venous access systems inserted in 163 consecutive children with cancer is reported. From 1988 to 1994, 180 subcutaneous ports were inserted in children more than 1...Full Text Available
Metacad is a collection of routines which creates a randomly accessible data structure from Applicon's APPLE-3D data format and supplies a logical method for manipulation of the data structure by a CAD application program.
Electronic personal health records (ePHRs) can potentially maximize access and coordination of health information and improve patient/clinician collaboration, patient self-management, and health outcomes....Full Text Available
The Clinical Summary is a Web-based application for accessing the clinical database at the Massachusetts General Hospital. The application has been developed to give physicians in our health care community...Full Text Available
The concept of "one-stop information shopping" is becoming a reality at Columbia-Presbyterian Medical Center. Our goal is to provide access from a single workstation to clinical, research, and library...Full Text Available
Background and objectives: Few studies have examined health literacy in patients with end stage kidney disease. We hypothesized that inadequate health literacy in a hemodialysis population is common...Full Text Available
... Radon gas concentrations are measured using instruments with calibrations traceable to the UK National Physical Laboratory and PTB, Germany. The primary facility is a 43 m3 walk-in chamber accessed by an airlock. Radon gas is maintained at a level in this chamber that is ...
BackgroundIn patients with Stage 5 Chronic Kidney Disease who require renal replacement therapy a major decision concerns modality choice. However, many patients defer the decision...Full Text Available
The Electronic REference To access In vivo Concentrations (ERETIC) method was applied to 1H HR-MAS spectroscopy. The accuracy, precision, and stability of ERETIC as a quantitative...Full Text Available
...comply with funding body archiving policies, including the policies put in place by the National Institutes of Health, The Wellcome Trust and the Howard Hughes Medical Institute . Delayed Access Select journals provide content to some or all of a journalrsquo;s backfile. For example, articles in ...
BackgroundWebsites of many rogue sellers of medications are accessible through links in email spam messages or via web search engines. This study examined...Full Text Available
For sufficiently cool remote gases, the cylindrical stretched flame shows classical ignition-extinction behavior. For remote gas temperatures close to the adiabatic flame temperature, the flame response is qualitatively different, with negative flame speed solutions which may be physically accessible.
This article compared conceptual and empirical strengths of alternative methods for estimating racial disparities using non-linear models of health care access. Three methods were presented...Full Text Available
ObjectiveThe objective of this study was to determine the contribution of distance to hospitals with cardiac interventional services (CIS) to county age-adjusted myocardial infarction...Full Text Available
Siderophores are essential factors for iron (Fe) acquisition in bacteria during colonization and infection of eukaryotic hosts, which restrain iron access through iron-binding protein, such as lactoferrin...Full Text Available
Cultured mouse or human embryonic stem (ES) cells provide access to all of the genes required to elaborate the fundamental components and physiological systems of a mammalian cell. Chemical or insertional...Full Text Available
There are a range of barriers precluding patients from fully engaging in and benefiting from the spectrum of eHealth interventions developed to support patient access to health information, disease...Full Text Available
Significant research has been devoted to predicting diagnosis, prognosis, and response to treatment using high-throughput assays. Rapid translation into clinical results hinges upon efficient access...Full Text Available
Apr 19, 1996 ... I learned that unlike most nuclear submarines that have 3 or more access routes, the NR-1 has just one hatch. At shallow depths, a rubber ...
...2010-10-01 false Special rules relating to group health plans. 146.145 Section 146.145 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES REQUIREMENTS RELATING TO HEALTH CARE ACCESS REQUIREMENTS FOR THE GROUP HEALTH...
...discrimination against participants and beneficiaries based on a health factor. 146.121 Section 146.121 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES REQUIREMENTS RELATING TO HEALTH CARE ACCESS REQUIREMENTS FOR THE GROUP HEALTH...
This book is not a traditional handbook. Engineers in industry need up-to-date, accessible information on the applications of heat and mass transfer. This book is the answer. Contents include: (1) emphasis on applications in thermal design and computer solutions of thermal engineering problems; (2) an introduction to the use of the Second Law of Thermodynamics in analysis, optimization, and economics; (3) information on topics of current interest--in a form convenient and accessible to the average engineer; (4) three chapters of background material--enough to review the basic principles needed to understand specific thermal applications; and (5) extensive treatment of computational tools and numerical analysis.
Polarized antiprotons produced by spin filtering with an internal polarized gas target provide access to a wealth of single- and double-spin observables, thereby opening a window to physics uniquely accessible with the HESR at FAIR. This includes a first measurement of the transversity distribution of the valence quarks in the proton, and a first measurement of the moduli and the relative phase of the time-like electric and magnetic form factors G{sub E,M} of the proton. In polarized and unpolarized pp-bar elastic scattering open questions like the contribution from the odd charge-symmetry Landshoff-mechanism at large |t| and spin-effects in the extraction of the forward scattering amplitude at low |t| can be addressed.
To expand the information base on molecular accessibility in solvent swelled coal, Argonne Premium Coal Samples (APCS) were swelled in polar, basic solvents before and after moisture loss and upon air oxidation. So far studies have been reported on the changes in pore size distribution as a function of temperature when polar basic swelling solvents are used. Additional studies employing EPR spin probe techniques performed on the breaking up of the hydrogen bonding between bedding planes were later confirmed by magnetic resonance imaging at Argonne National Lab and the University of Illinois.
Choosing a medical device is complex and requires a transparent process based on reason, evidence and assessment of prioritized public health needs. Poor choices lead to inappropriate use or non-use of medical devices and a waste of resources.This report suggests how an agenda to improve access to appropriate medical devices could be devised from applying the crucial 4 components - Availability, Accessibility, Appropriateness, and Affordability, to the 15 global high-burden diseases and some cross-cutting issues. The results of this exercise suggest several areas of research necessary to help
During 2009, the Hilton M. Briggs Library, South Dakota State University, went live with MetaLib, a federated search engine from Ex Libris. This paper presents the implementation process, addresses resource accessibility issues, and suggests a number of resources that can be consulted about these issues. Readers can apply similar strategies to projects involving federated search systems, as many implementation projects involve the same basic considerations presented here. The author did not find any studies specifically focused on configurations of MetaLib resources, so this content should be singularly useful.
CERN, DESY, Fermilab and SLAC have joined forces to build INSPIRE, the next-generation HEP information platform offering innovative tools for information discovery and communication. Representing a natural community-based evolution of SPIRES, INSPIRE provides fast access to the entire body of HEP literature. As a subject repository it will host fulltexts of preprints, Open Access journal articles and supplementary material like conference slides and multimedia, enabling novel text- and data mining applications. In the spirit of Web2.0 INSPIRE will also supply tools for collaboration and user-enriched content.
The immense volume of data generated by the suite of instruments on SDO requires new tools for efficient identifying and accessing data that is most relevant to research investigations. We have developed the Heliophysics Events Knowledgebase (HEK) to fill this need. The HEK system combines automated data mining using feature-detection methods and high-performance visualization systems for data markup. In addition, web services and clients are provided for searching the resulting metadata, reviewing results, and efficiently accessing the data. We review these components and present examples of their use with SDO data.
Purpose - The purpose of this paper is to describe the processes and procedures utilized by Jacksonville State University's Houston Cole Library to digitize an oral history collection and provide access to it through the Library's catalog, web presence, and the state-wide digital repository initiative, Alabama Mosaic (see www.alabamamosaic.org). Design/methodology/approach - The paper is based on the Library's experiences in acquiring, digitizing, creating metadata for and making accessible a collection of oral histories. Findings - The paper describes the obstacles overcome, issues encountered, procedures established, and ramifications of the project. Practical implications - Many institutions are currently digitizing unique collections as part of repository initiatives, both institutiona...
The Northwest Foster Care Alumni Study examined the relation between experiences in foster care and depression among young adults who spent at least a year in foster care as adolescents. Results indicate that preparation for leaving foster care, nurturing supports from the foster family, school stability, access to tutoring, access to therapeutic service and support, and a shorter and more stable placement history were associated with a lower probability of depression in young adulthood. Results provide evidence that suggest ways to improve practice to decrease rates of depression among alumni of care. (Contains 2 tables.)
A database has been designed for storing, retrieving and analyzing information about samples, experimental conditions and results obtained by neutron activation analysis and gamma-ray spectrometry. It has been created using Microsoft ACCESS 2002 under a Windows operating system. The database has been designed not only for saving information but also for quality assurance and quality control purposes. The structure of the relational design has been discussed and demonstrated with a new graphical feature of ACCESS 2002 called PIVOTCHART. (author)
The work examines twenty-two patients with coronary artery disease, previous myocardial infarction and LV dysfunction, using the technetium-99m ({sup 99m}Tc) tetrofosmin (SPECT) associated with nitrate administration in the detection of hypoperfused but still viable myocardium. The method allows the detection of this disease. [Italian] Il lavoro analizza i risultati degli esami condotti su 22 pazienti con cardiopatia ischemica cronica e ridotta funzione ventricolare sinistra sottoposti a tomografia computerizzata con emissione di fotone singolo (SPECT) cardiaca con tecnezio-99m ({sup 99m}Tc) tetrofosmina associata alla somministrazione di nitrati nella differenziazione tra tessuto miocardico ipoperfuso ma ancora vitale e tessuto miocardico necrotico. La metodologia usata consente di identificare la presenza di tessuto miocardico vitale in territori vascolari severamente ipoperfusi.
To assess the malignant potential of small({<=}15mm) portal defects seen on CT arterial portography, the findings of CT hepatic arteriography and lipiodol CT were reviewed. In 91 patients who underwent both CTAP and CTHA, small portal defects were reviewed for frequency, multiplicity and location. We prospectively evauluated changes in the size and enhancement pattern of malignant lesions on follow up CT according to density on CTHA, location, lipiodol deposits on lipiodol CT, and multiplicity. Among the 91 patients, 102 small defects were defected in 42 patients(46%). Small portal defects were benign, malignant, and of undetermined malignant potential in 77%, 20% and 3% of cases, respectively. Small portal defects that were hyperattenuated on CTHA, and lipiodol deposits on lipiodol CT, were malignant in 42% and 70% of cases, respectively. Location and multiplicity did not show statistically significant variation between benign and malignant defects. Small ...
We studied regional myocardial perfusion by scintigraphic computer-assisted analysis of initial distribution, washout rates, and residual activity of "1"3"3Xe injected into the left coronary artery of four patients with normal arteriograms and 14 patients with coronary stenosis. At rest, residual activity in poststenotic regions was always greater than in control regions, but initial washout rates were not slower. During angina, following xenon injections, the amount of indicator distributed to the poststenotic regions was markedly reduced; the increase of the initial washout rates was smaller than in control regions relative to rest, and residual activity was higher. Initial washout rates did not differ as much as from those of normal myocardium because in severe ischemia too little indicator is deposited initially in these regions to produce a change of any magnitude. Indeed, when angina was induced immediately after the xenon injection, poststenotic washout ...
Abstract in english We hypothesized that chronic oral administration of the phosphodiesterase-5 inhibitor sildenafil could improve the exercise capacity and pulmonary hemodynamics in patients with pulmonary arterial hypertension (PAH) on the basis of previous short-term studies. We tested this hypothesis in 14 subjects with PAH, including seven patients with the idiopathic form and seven patients with atrial septal defects, but no other congenital heart abnormalities. Patients were subjected (more) to a 6-min walk test and dyspnea was graded according to the Borg scale. Pulmonary flow and pressures were measured by Doppler echocardiography. Patients were given sildenafil, 75 mg orally three times a day, and followed up for 1 year. Sildenafil therapy resulted in the following changes: increase in the 6-min walk distance from a median value of 387 m (range 0 to 484 m) to 462 m (range 408 to 588 m; P
The effects of 0.2 and 0.5 mL/kg Innovar (a neuroleptic analgesic) on cardiovascular functions and reflexes in rabbits were measured. We recorded the effects of Innovar on arterial pressure, heart rate, respiration rate, ventricular contractility, arterial oxygen tension, as well as the drug's effects on the bradycardia and vasoconstrictor response to cigarette smoke stimulation of the nose (the so-called "nasopharyngeal reflex"). In animals given 0.2 mL/kg Innovar, all steady state cardiovascular variables had returned to pre-Innovar levels in 45 min, as had the efficacy of the nasopharyngeal reflex. In animals given 0.5 mL/kg Innovar, all steady state cardiovascular variables, except PaO2, were slightly but significantly depressed for up to 135 min after injection. The nasopharyngeal reflex returned to normal within 90 min. Because of the calmative and analgesic effects of Innovar, and its only moderate effects on cardiovascular functions and ...
The diagnostic accuracy is compared of the dual-isotope protocol and the conventional "2"0"1Tl protocol, for detection of the coronary artery disease (CAD) using data on a total of 69 patients after myocardial infarction (MI). The "2"0"1Tl protocol was used to examine 44 patients, the dual-isotope protocol was used with 25 patients. All patients were examined by coronarography; a narrowing of the artery by more than 50 % was considered significant for CAD. The sensitivity, specificity and diagnostic accuracy was 97.7 %, 100 % and 97.7 % resp. for the "2"0"1Tl protocol, and 95.2 %, 75 % and 92 % resp. for the dual-isotope protocol. A higher diagnostic accuracy of the dual-isotope protocol has not been proven, and the "2"0"1Tl protocol continues to be used for examinations of patients after MI
The purpose of this study was to determine whether low doses of carbon monoxide (CO) exacerbate myocardial ischemia during a progressive exercise test. The effect of CO exposure was evaluated using the objective measure of time to development of electrocardiographic changes indicative of ischemia and the subjective measure of time to onset of angina. Sixty-three male subjects (41-75 years) with well-documented coronary artery disease, who had exertional angina pectoris and ischemic ST-segment changes in their electrocardiograms, were studied. Results from three randomized, double-blind test visits (room air, low and high CO) were compared. The effect of CO exposure was determined from the percent difference in the end points obtained on exercise tests performed before and after a 1-hr exposure to room air or CO. A significant dose-response relationship was found for the individual differences in the time to ST end point and angina for the pre-versus postexposure ...
The effects of cocaine on the maternal and fetal pituitary-adrenal axis in vivo during pregnancy have not been reported. Six pregnant ewes and their fetuses underwent instrumentation at 113 to 119 days' gestation. Ewes were assigned to receive an intravenous bolus injection of vehicle or cocaine (0.5, 1.0, or 2.0 mg.kg-1) at 124 to 136 days' gestation. Maternal arterial blood gases, fetal pH and fetal PCO2 were unchanged after injection of cocaine or vehicle. After administration of 2.0 mg.kg-1 cocaine, arterial fetal PO2 fell 3.2 +/- 1.72 mm Hg (p less than 0.05) at +5 minutes, returning to baseline by +15 minutes. Maternal and fetal adrenocorticotropin levels rose within 5 minutes after the highest cocaine dose (p less than 0.05). There was a significant (p less than 0.05) increase in maternal cortisol at all doses of cocaine and in fetal cortisol at +15 minutes after the 2.0 mg.kg-1. PMID:1847006
Purpose: The lifelong persistence of foreign bodies within the arteries may contribute to restenosis. Thus,biodegradable devices might decrease recurrence rates. Methods: Eleven polyhydroxybutyrate biodegradable stents and 13 tantalum stents were implanted into the iliac arteries of New Zealand white rabbits for up to 30 weeks. After killing the animals,the specimens were harvested, fixed in formalin, processed in paraffin,and stained. Results: Polyhydroxybutyrate instigated intense inflammatory and proliferative reactions with an increase in collagen (2.4- to 8-fold vs native segments), thrombosis and in-stentlumen narrowing (375.5-606.6 mm vs 655.6 #+-# 268.8 mm in native segments). The elastic membranes were destroyed in all specimens. The tantalum stents increased the in-stent lumen progressively (769.7 #+-# 366.6 mm vs 1309.9 #+-# 695.3 mm),penetrated the external elastic membrane, and increased mural collagen content (6- to 8.6-fold vs ...
;Contents: Comparison of Simulation Modules of TRANSYT and INTEGRATION Models; Evaluation of SCATSIM-RTA Adaptive Traffic Network Simulation Model; Comparison NETSIM, NETFLO I, and NETFLO II Traffic Simulation Models for Fixed-Time Signal Control; Traffic Flow Simulation Through Parallel Processing; Cluster Analysis as Tool in Traffic Engineering; Traffic Platoon Dispersion Modeling on Arterial Streets; Hybrid Model for Estimating Permitted Left-Turn Saturations Flow Rate; and Passing Sight Distance and Overtaking Dilemma on Two-Lane Roads.
Positron emission tomography (PET) and X-ray computed tomography (CT) performed with PET/CT cameras allow us to obtain concurrently information on the presence and degree of alterations of myocardial perfusion and metabolism and on coronary arteries calcification. Furthermore, by gated myocardial perfusion studies, PET may provide crucial information on regional coronary blood flow reserve and endothelial dysfunction. A number of recent papers provide some insight on the potential of PET/CT in cardiology and in the assessment of various cardiovascular diseases including various types of vasculitis and metabolic diseases.
A 60-year-old male was bitten by a venomous snake (Vipera ammodytes) and gradually developed signs of an allergic reaction including generalized itching, generalized rash, and chest discomfort. This was followed by severe retrosternal pain with electrocardiographic evidence of an inferior myocardial ischemia progressing to acute myocardial infarction. Cardiac enzymes and troponin, serum tryptase, and histamine were elevated. Coronary arteriography showed normal coronary arteries. This is a characteristic type I variant of Kounis syndrome, which is the concurrence of acute coronary syndromes with conditions associated with mast cell activation including allergic or hypersensitivity reactions as well as anaphylactic or anaphylactoid reactions. This is the first report to show that viper bite...
Materials and methods: 12 patients with 22 coronary bypass grafts underwent intraoperative flow quantification using the transit time ultrasound method. These values were compared to postoperative MR phase shift measurements. Flow measurements were performed preoperatively in 28 coronary arteries of 20 patients. For flow measurement, we used a velocity-encoded k-space segmented gradient echo sequence with a temporal resolution of 110 or 125 ms, respectively. 6-8 pase shift images could be acquired during one cardiac cycle. Results: There was a significant correlation between intraoperative and flow measurements using velocity-encoded MR imaging (r=0.76, p<0.0001, t-test). Flow volumes determined by MR imaging were systematically larger than those determined by the transit time ultrasound method. Mean flow in coronary arteries was reduced in severely stenosed vessels (>70%) compared to normal vessels. Intra- and interobserver ...
The purpose of this study was to test a large sample of different coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in 64-slice multidetector-row computed tomography (MDCT) in vitro and to provide a catalogue of currently used coronary artery stents when imaged with state-of the-art MDCT. We examined 68 different coronary artery stents (57 stainless steel, four cobalt-chromium, one cobalt-alloy, two nitinol, four tantalum) in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70). Stents were imaged in axial orientation with standard parameters: 32x0.6 collimation, pitch 0.24, 680 mAs, 120 kV, rotation time 0.37 s. Four different image reconstructions were obtained with varying convolution kernels and section thicknesses: (1) soft, 0.6 mm, (2) soft, 0.75, (3) ...
The aim of the study was the attempt to evaluate the influence of two different methods of cardiac perfusion SPECT reconstruction (FBP and ITW) on clinical efficacy in diagnosing the coronary artery disease as well as the cardiac ischemia detection in three areas of heart vascularized by main coronary arteries: LAD, LCX and RCA with the use of artificial neural networks (ANN). The study was performed retrospectively with the use of the diagnostic image records as well as clinical dataset of 43 patients. Myocardial perfusion stress/rest SPECT study and X-ray coronarography data were evaluated for each patient. The results of coronary angiography were considered the reference method. The cardiac SPECT data were reconstructed using the two different methods: filtered backprojection (FBP) and iterative Wallis method (ITW). The local perfusion deficits denominated in stress and rest study in three main vessel cardiac segments were the main input ...
We labelled Lipiodol with yttrium-90 and analysed the biodistribution in rats after intrahepatic arterial injection. An RP-18 column was used to separate {sup 90}Y from strontium-90. {sup 90}Y was retained on the column, which had been pretreated with yttrium-selective extraction reagent, di(2-ethylhexyl) phosphate, while {sup 90}Sr was washed out. A hexadentate nitrogen-donor chelating ligand N,N,N`,N`-tetrakis(2-benzymidazolylmethyl)-1,2-ethanediamine (EDTB) was synthesized by condensation of 1,2-benzenediamine and ethylene diamine tetra-acetic acid (EDTA). Lipiodol was covalently conjugated with EDTB. The final product was obtained by eluting the retained {sup 90}Y from the RP-18 column with EDTB-Lipiodol. Sixteen male rats (Sprague-Dawley) were sacrificed at 1 h, 24 h, 48 h and 72 h (four rats at each time) after injection of approximately 0.1 mCi {sup 90}Y-Lipiodol via the hepatic artery. Samples of liver, spleen, muscle, lung, kidney, ...
The natriuretic peptides are considered to be cardioprotective; however, their receptors have not been identified in human myocardium using radiolabeled analogs. Dendroaspis natriuretic peptide (DNP) has been recently identified as a new member of this peptide family and is thought to be less susceptible to enzymatic degradation. Therefore, we have developed the novel radiolabeled analog [125I]-DNP and used this to localize high-affinity (K(D)=0.2 nmol/L), saturable, specific binding sites in adult human heart (n=6) and coronary artery (n=8). In competition binding experiments, atrial natriuretic peptide and brain type natriuretic peptide had greater affinity for [125I]-DNP binding sites than C-type natriuretic peptide and the natriuretic peptide receptor (NPR)-C ligand, cANF. This rank order of potency suggested binding of [125I]-DNP was specific to NPR-A. Messenger RNA encoding NPR-A was identified in left ventricle and coronary artery smooth ...
The frequency of peripheral pulmonary artery stenosis in patients after surgical repair of tetralogy of Fallot (TOF) ranges from 20 to 40%. This can be either primary or secondary to the surgical intervention. The influence of resulting lung perfusion alterations on the life quality of patients is difficult to predict. The aim of this study was to compare the utility of the diagnostic procedures in this group of patients, with particular focus on lung perfusion scintigraphy. This study comprised 104 patients who underwent repair of TOF at ages from 5 months to 25 years. The patients have been followed up for from 4.2 to 25 years. On the basis of chest X-ray peripheral pulmonary artery stenosis was suspected in 11 patients, in 12 on the basis of echocardiography examination. Lung perfusion scintigraphy has been performed on 87 patients. The disturbances in lung perfusion (mostly in the left lung) were show by means of lung perfusion scintigraphy ...
Purpose: To assess the relationship between large intracranial vessel occlusive vasculopathy (vasculopathy) and radiation therapy, and to clarify the clinical efficacy of magnetic resonance (MR) imaging in the diagnosis and screening of the vasculopathy. Methods and Materials: We retrospectively evaluated the medical records and serial MR images for 32 pediatric patients, in whom radiation therapy had been given to fields including the circle of Willis and major cerebral arteries. All children had periodically undergone follow-up neurologic assessment and MR imaging examinations at Kanagawa Children's Medical Center for more than one year after radiation therapy (range 1.3-14 years). Patients who had not remained free of tumor progression up to the time of final evaluation were excluded. Results: Vasculopathy developed in 6 of 32 patients 2-13 years after radiation therapy. Three of them presented with transient ischemic attacks (TIA) and the other three showed ...
Accurate diagnosis of local invasion of hilar cholangiocarcinomas is challenging due to their small size and the anatomic complexity of the hepatic hilar region. On the other hand, the correct diagnosis of local invasion is essential for assuring the possibility of curative surgery. The purpose of this study was to evaluate the feasibility of four-channel multidetector-row computed tomography (MDCT) in the assessment of vascular and bile duct involvement, by which we could obtain useful information for the surgical management of hilar cholangiocarcinoma. The subjects were 18 patients for whom the extent of tumor invasion was surgically and pathologically confirmed. All patients underwent preoperative multiphasic CT scanning by MDCT. Arterial and portal dominant phases were acquired using a detector configuration of 1.25 mm x 4 mm, and both axial and multiplanar reconstructed images were interpreted. Longitudinal extension was evaluated up to second-order branches. ...
Medetomidine and fentanyl-droperidol (Innovar-vet) were assessed over a three hour period in 80 healthy dogs. Following physical examination, electrocardiogram (ECG), arterial blood sample analysis, and dynamometer pressure threshold (analgesia score), the dogs were randomly assigned to one of four treatments: Miv--medetomidine (750 micrograms/M2) administered intravenously (IV), Mim--medetomidine (1000 micrograms/M2) administered intramuscularly (IM), Iiv--Innovar-vet IV (0.05 mL/kg) or Iim--Innovar-vet IM (0.1 mL/kg). All assessments were carried out by a single individual unaware of the treatment used. Objective assessments included temperature, heart and respiratory rates, analgesia score, arterial blood gases, acid-base and lactate levels. Subjective evaluation included degree of sedation, response to various clinical procedures, noise responsiveness, posture, and the incidence of side effects. Onset and duration of effect were also ...
A hypothesis of microwave-induced circulatory under perfusion was tested in ketamine anesthetized rats whose heart rate, mean arterial pressure, pulse pressure, respiration rate, and body temperatures were monitored continuously. Fifty-eight ventral head and neck exposures in a waveguide consisted of sham-exposure and exposure to continuous wave (CW) and pulsed 1.25 GHz microwaves for 5 min. The 0.5 Hz and 16 Hz pulsemodulated microwaves were delivered at 400 kW peak power. The CW microwaves were 2 and 6.4 W. The average specific absorption rate was 4.75 W/kg per watt transmitted in the brain and 17.15 W/kg per watt transmitted in the neck. Respiration rate and mean arterial pressure were not altered. Changes in heart rate and pulse pressure were observed in rats exposed to higher power but not to the lower average power microwaves. Depression of pulse pressure, an indication of a decrease in stroke volume, and increased or decreased heart rate ...
In a recent survey of the stellar populations of LINERS and LINER/HII Transition Objects (TOs) we identified a numerous class of nuclei which stand out because of their conspicuous 10^8-9 yr populations. These objects were called ``Young-TOs'', since they all have TO-like emission line ratios. In this paper we investigate the radial variations of spectral properties in Low Luminosity AGN. Our analysis is based on high S/N, 3500-5500 A, long-slit spectra for 47 galaxies. The data probe distances of typically up to 850 pc from the nucleus with a resolution of ~ 100 pc and S/N ~ 30. Stellar population gradients are mapped by the radial profiles of absorption line equivalent widths and colours along the slit. These variations are further analyzed by means of a decomposition of each spectrum in terms of template galaxies representative of very young (<= 10^7 yr), intermediate age (10^8-9 yr) and old (10^10 yr) populations. Our main findings are: ...
The stellar disc kinematics in a sample of fifteen intermediate- to late-type edge-on spiral galaxies are studied using a dynamical modeling technique. The sample covers a substantial range in maximum rotation velocity and deprojected face-on surface brightness and contains seven spirals with either a boxy- or peanut-shaped bulge. Dynamical models of the stellar discs are constructed using the disc structure from $I$-band surface photometry and rotation curves observed in the gas. The differences in the line-of-sight stellar kinematics between the models and absorption line spectroscopy are minimized using a least-squares approach. The modeling constrains the disc surface density and stellar radial velocity dispersion at a fiducial radius through the free parameter $\\sqrt{M/L}$ $(\\sigma_{\\rm z}/\\sigma_{\\rm R})^{-1}$, where $\\sigma_{\\rm z}/\\sigma_{\\rm R}$ is the ratio of vertical and radial velocity dispersion and $M/L$ the disc ...
% In this work we investigated, in the Smooth Particle Hydrodynamics (SPH) framework, the development of spiral structures and shock fronts in the radial flow of accretion discs in close binary systems. These shock waves take place when the initially supersonic radial flow penetrating the disc bulk, reduces substantially its speed becoming suddenly subsonic. To this purpose, keeping constant the mass of the compact primary (M1 = 1 MO ), the separation between the two components and the injection speed at the inner Lagrangian point L1 (close to the local sound speed), we carried out 2D SPH simulations for four values of the stellar mass ratio M2/M1. We worked out 2D models because the damping effect of the artificial viscosity is too strong in 3D. Furthermore, the 2D environment seems the most suitable in order to evidence shock fronts in highly compressible gases. The results show that spiral structures and shock fronts develop for low values ...
The numerical calculation of oscillatory wavefunctions occurring in the theory of electron scattering from positive ions is considered, the aim being to develop methods for evaluating the oscillatory solutions using a logarithmic grid. Thus, the permitted step-size for the solution depends only upon the potential, enabling calculations at different energies to be performed using the same discretisation. Two similar generalisations of the W.K.B. transformation for second order ordinary differential equations are made and applied to the radial Dirac equations. Iterative schemes for the solution of the resulting non-linear amplitude equations are discussed, one for use in the asymptotic region and the other a Newton scheme for continuing the solution closer to the origin. Using these techniques a reliable and efficient program for calculating relativistic scattering phase shifts from ionic potentials has been written. Relativistic Optical Model problems have been ...
Optimal capacitor placement determines the size, type, and location of capacitors to be installed on a radial distribution feeder that will reduce peak power and energy losses while minimizing the costs of investment and installation of the capacitor banks. This paper describes a sensitivity-based optimal placement of capacitors that employs a new load characterization scheme using a voltage-current-angle-logger. The proposed method allows modeling of loads of different power factors for different portions of the distribution feeder. The optimal solution is obtained by testing various combinations of capacitor banks (based on the smallest bank size specified by the user) and candidate nodes along the distribution feeder, and calculating the resultant savings. In order to reduce solution time, the candidate nodes are ranked according to their sensitivity factors. The highest ranking nodes are considered first in the optimization process. At a node where the ...
The macroscopic rotation of plasma in a toroidal containment device is an important feature of the equilibrium. Toroidal and polidal rotation in the high-beta tokamak Torus II is measured experimentally by examining the Doppler shift of the 4685.75 A He II line emitted from the plasma. The toroidal flow at an average velocity of 1.6 x 10/sup 6/ cm/sec, a small fraction of the ion thermal speed, moves in the same direction as the toroidal-plasma current. The poloidal flow follows the ion diamagnetic current direction, also at an average speed of 1.6 x 10/sup 6/ cm/sec. In view of certain ordering parameters, the toroidal flow is compared with predictions from neoclassical theory in the collisional, Pfirsch-Schluter regime. The poloidal motion, however, results from an E x B drift in a positive radial electric field, approaching a stable ambipolar state. This radial electric field is determined from theory by using the measured poloidal velocity. ...
The macroscopic rotation of plasma in a toroidal containment device is an important feature of the equilibrium. Toroidal and poloidal rotation in the high beta tokamak Torus II is measured experimentally by examining the Doppler shift of the 4685.75 A He II line emitted from the plasma. The toroidal flow at an average velocity of 1.6 x 10/sup 6/ cm/sec, a small fraction of the ion thermal speed, moves in the same direction as the toroidal plasma current. The poloidal flow follows the ion diamagnetic current direction, also at an average speed of 1.6 x 10/sup 6/ cm/sec. In view of certain ordering parameters, the toroidal flow is compared with predictions from neoclassical theory in the collosional, Pfirsch-Schluter regime. The poloidal motion, however results from an E x B drift in a positive radial electric field, approaching a stable ambipolar state. This radial electric field is determined from theory by using the measured poloidal velocity. ...
The performance of the new combustor was tested. Experiments showed that this combustor has superior insulating quality than the previous one. Measured radial concentrations indicated uniform distribution of the primary fuel (coal) inside the fire tube resulting in reasonably flat concentration profiles. However, measured radial concentrations after the addition of the reburn fuel showed uneven distribution of the fuel resulting in parabolic concentration profiles, an indication of insufficient mixing in the reburn zone. In order to study mechanisms of nitrogenous species destruction in the reburn zone, it is necessary to achieve adequate mixing if the assumption of one dimensional plug flow behavior is to be valid. Thus, it became necessary to modify the injector design and the injection mode of the reburn fuel to achieve an adequate level of mixing which is the focus of this report. The results show that a minimum reburn fuel jet velocity of ...
It is well known that composite armors, consisting of glass elements confined with metallic tampers, are extraordinarily effective against shaped charge attack. Early experiments showed that jets fired against glass targets appeared to be bombarded by tiny fragments that destroyed alignment and reduced residual jet penetration. This result was attributed to an elastic rebound effect in which the outward radial motion of the target around the jet periphery was supposed to be arrested by tensile hoop stresses which developed behind the divergent shock front. Glass fragments were then accelerated radially inward and these destabilized the jet. To sustain the large tensile hoop stresses required, the glass must not have been fractured by the initial shock, behind which the stress state is typically well above the Hugoniot elastic limit. Modeling the penetration of a jet into glass requires not only determining the spall strength, i.e., the tensile ...
A parametric experimental investigation of an 85 millimeter bore angular contact ball bearing running in RP-1 fuel was performed at speeds of 10,000 to 24,000 rpm. Thrust loads were varied from 4450 to 17,800 Newtons (1000 to 4000 lbs.). Radial loads were varied from 1335 to 13,350 Newtons (300 to 3000 lbs.). RP-1 lubrication for the bearing was provided through a stationary jet ring located adjacent to the test bearing outer ring. Increases in both the thrust and radial loads resulted in increased bearing temperature, while increases in shaft speed resulted in much more dramatic increases in bearing temperature. These trends are typical for ball bearings operating under these types of conditions. Results are given for outer ring temperatures of the test bearing at the various test conditions employed. In addition, the heat energy removed from the bearing by the RP-1 was determined by measuring the increase in temperature as the RP-1 passed ...
The Moderator Temperature Coefficient of reactivity (MTC) was earlier proven to be properly determined via noise analysis when the neutron noise is measured locally and when the radial average of the moderator temperature noise is used. Nevertheless, measurements revealed that the MTC was correctly estimated on a much narrower frequency band (0.6 - 0.7 Hz) than expected (0.1 - 1.0 Hz). The present paper investigates the effect of the feedback on the MTC determination using this new MTC noise estimator (which could explain the deviation at low frequencies, i.e. between 0.1 - 0.5 Hz) and the effect of the detector time constants (which could explain the deviation at high frequencies, i.e. between 0.7 - 1.0 Hz). For that purpose, a coupled neutronic/thermalhydraulic model of the Ringhals-3 PWR is developed in the frequency-domain, based on a radial 2-dimensional heterogeneous representation of the core. The transfer function of the detectors is ...
Detailed spray characteristics were obtained for a small-capacity, pressure-swirl atomizer using an Aerometrics phase-Doppler particle analyzer. Measurements included drop size and velocity distributions, liquid volume fluxes, and air velocities at four axial locations, 25,50,75, and 100 mm, with complete radial traverses at each location. Drop size results were compared with measurements from a Malvern laser-diffraction instrument, and integrated liquid volume fluxes were compared with measured flow rates to estimate measurement uncertainties. Drop sizes measured by the two independent techniques and area-weighted-averaged over the radial traverses at each of the four axial stations varied on average by less than 4 percent. Integrated volume flux measurements by the phase-Doppler instrument at four axial stations differed from the nozzle flow rate by at most 19 percent, with some of the difference due to evaporation. The phase-Doppler data ...
The thermal and heat transfer characteristics of stearic acid during the solidification processes were investigated experimentally in a vertical annulus energy storage system. The temperature distribution and temperature variations with time at different radial positions during the freezing processes were obtained. The thermal characteristics of the stearic acid, including movement of the solid-liquid interface in the radial direction, and the effects of Reynolds number on the heat transfer parameters were studied. The heat flux was estimated by using a simple approximate model. A new copper fin was designed and fixed to the electrical heating rod to enhance the thermal conductivity of the stearic acid. The results show that the new fin can enhance both the conduction and the natural convection heat transfer of the PCM, and the enhancement factor during solidification is estimated to be as high as 250%. The effect of the fin width on the ...
The thermal and heat transfer characteristics of stearic acid during the solidification processes were investigated experimentally in a vertical annulus energy storage system. The temperature distribution and temperature variations with time at different radial positions during the freezing processes were obtained. The thermal characteristics of the stearic acid, including movement of the solid-liquid interface in the radial direction, and the effects of Reynolds number on the heat transfer parameters were studied. The heat flux was estimated by using a simple approximate model. A new copper fin was designed and fixed to the electrical heating rod to enhance the thermal conductivity of the stearic acid. The results show that the new fin can enhance both the conduction and the natural convection heat transfer of the PCM, and the enhancement factor during solidification is estimated to be as high as 250%. The effect of the fin width on the ...
This paper deals with electron flux densities and electron energy flux densities in positive column discharges. Recent kinetic calculations by Uhrlandt and Winkler have revealed the interesting physical phenomenon of radially inward directed energy flux densities in positive column plasmas. We have used a self-consistent positive column model, based on an accurate and highly detailed Monte Carlo code, to study this effect in more depth. The results of this study show a rather complex physical picture of electron particle and energy flux densities. Electrons with low energies usually exhibit radially outward directed particle and energy flux densities. At energies above the threshold for electronic excitation particle and energy flux densities are usually inward directed. Only close to the wall, at total energies above the wall potential energy, do these flux densities point towards the wall. The thickness of this 'wall loss ...
A study on development of magnetic drive packless valves for commercial purpose showed the results as follows; 1. Study on the radial rays effecting to the permanent magnets -Measurement of the strength of Nd-magnets according to irradiation of radial rays. 2. Effects of temperature on the magnetic driving device -Temperature dependency of the Nd-casting magnets. -Effects of temperature on the heat releasing fins of high-temperature valve. 3. Optimization of torque -Arranging method of permanent magnets -Measuring method and results of torque. 4. Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Calculation and design for the flat circular plates under pressure of the magnetic power transmitting device -Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Comparison of the characteristics between magnetic drive valve and ...
We model the transport of cosmic ray nuclei in the Galaxy by means of a new numerical code. Differently from previous numerical models we account for a generic spatial distribution of the diffusion coefficient. We found that in the case of radially uniform diffusion, the main secondary/primary ratios (B/C, N/O and sub-Fe/Fe) and the modulated antiproton spectrum match consistently the available observations. Convection and re-acceleration do not seem to be required in the energy range we consider: $1 \\le E \\le 10^3$ GeV/nucleon. We generalize these results accounting for radial dependence of the diffusion coefficient, which is assumed to trace that of supernova remnants. While this does not affect the prediction of secondary/primary ratios, the simulated longitude profile of the diffuse $\\gamma$-ray emission is significantly different from the uniform case and may agree with EGRET measurements without invoking {\\it ad hoc} assumptions on ...
Abstract in english In this work the air flow in a furnace was computationally investigated. The furnace, for which experimental test data are available, is composed of a movable block burner connected to a cylindrical combustion chamber by a conical quarl. The apertures between the movable and the fixed blocks of the burner determine the ratio of the tangential to the radial air streams supplied to the furnace. Three different positions of the movable blocks were studied at this time. A thr (more) ee-dimensional investigation was performed by means of the finite volume method. The numerical grid was developed by the multiblock technique. The turbulence phenomenon was addressed by the RNG k-epsilon model. Profiles of the axial, tangential and radial velocities in the combustion chamber were outlined. The map of the predicted axial velocity in the combustion chamber was compared with a map of the experimental axial velocity. The internal space ...
To investigate the magnetic fluctuations and for further transport study, the poloidal and radial magnetic field measurement is conducted on the Sino United Spherical Tokamak (SUNIST). Auto-power spectral density indicates that the magnetic fluctuation energy mainly concentrates in the frequency region lower than 10 kHz. The magnetic field oscillations, which are characterized by harmonic frequencies of 40 kHz, are observed in the scrape-off layer; by contrast, in the plasma core, the magnetic fluctuations are of Gaussian type. The time-frequency profiles show that the poloidal magnetic fluctuations are temporally intermittent. The autocorrelation calculation indicates that the fluctuations in decorrelation time vary between the core and the edge. (authors)
In drift tube linacs a beam energy spread results form the finite beam size. Radial variation of the axial accelerating field induces a beam energy spread, which, in general, will accumulate as the beam passes through successive drift tubes. This paper shows that under some conditions of periodic transverse focusing and longitudinal phase focusing, the correlation between the longitudinal and transverse motion can be used to correct the energy spread. The process of achieving such a correction is first described in a simplified situation, and then demonstrated for a particular tuning using a ray-tracing program which models a low velocity and low charge state linac designed for radioactive ion beams.
Network reconfiguration is an operation problem, which entails altering the topological structure of the distribution feeders by rearranging the status of switches in order to obtain an optimal configuration in order to minimise the system losses. This paper presents a new reconfiguration algorithm that enhances voltage stability and improves the voltage profile besides minimising losses without incurring any additional cost for installation of capacitors, tap changing transformers and related switching equipment in the distribution system. Test results on a 69 node distribution system reveal the superiority of this algorithm.