WorldWideScience
 
 
1

Gamma radiation (Co{sup 60}) effects on active substances and microbe burden of medicinal plants; Avaliacao dos efeitos da radiacao gama (Co{sup 60}) sobre principios ativos e carga microbiana de plantas medicinais  

Energy Technology Data Exchange (ETDEWEB)

In order to evaluate the effects of radioactivity on active vegetal substances, samples of Fennel (Foeniculum vulgare Miller., fructus), Guarana (Paulinia cupana, Kunth, semen), Gingko (gingko biloba, L., folium), and Kawa-Kawa (Piper methysticum G. Forst, rhizoma), were treated with scaling doses (0 to 25 KGy) of gamma radiation (Co{sup 60}). The 'blind test' methodology was used. The active substances from each sample were analysed by qualitative and quantitative methods after radiation. There were no significant differences seen between the control sample (0 KGy) and the irradiated samples. Microbe contamination was significantly reduced, about 10000 CFU/g, with the initial 5 KGy dose. It was concluded that gamma radiation can be used as an alternative procedure to reduce microbiologic contamination in medicinal plants. Before this procedure can be extended to other medicinal plants, more specific analytical methods are recommended to verify possible structural ...

2001-04-01

2

Utilisation of gamma radiation of Cobalt-60 as quarantine treatment of medicinal plant, aromatic and seasoning plants dehydrated infested by Lasioderma serricorne (Fabricius, 1792) (Coleoptera, Anobiidae) and Plodia interpunctella (Hubner, 1813) (Lepidoptera, Pyralidae); Utilizacao da radiacao gama do Cobalto-60 como tratamento quarentenario de plantas medicinais, aromaticas e condimentares desidratadas infestadas por Lasioderma serricorne (Fabricius, 1792) (Coleoptera, Anobiidae) e Plodia interpunctella (Hubner, 1813) (Lepidoptera, Pyralidae)  

Energy Technology Data Exchange (ETDEWEB)

The research had as objective the use of the gamma radiation of the Cobalto-60 as quarantine treatment of the medicinal plant, aromatic and seasoning plants dehydrated infested by Lasioderma serricorne and Plodia interpunctella determining the disinfestation doses to attend the criterion in the not emergency of adults of the species in study and analysing through the Chromatography of Thin Layer the effect of the gamma radiation of the cobalto-60 on the active principle of extract dehydrated of Chamomilla recutita, Pimpinella anisum, Origanum vulgare, Cymbopogon citratus, Ocimum basilicum and Thymus vulgaris. The work was developed in the Laboratorio de Inseticidas in the Instituto Biologico in Sao Paulo in the period of August of 2005 the June of 2007. The radiation source used gamma was an experimental irradiator of Cobalto-60, model Gamacell 220, located in the Instituto de Pesquisas Energeticas e Nucleares - IPEN, located in Sao Paulo. In the period of 30 days after the irradiation ...

2007-07-01

3

Study of the effect of gamma radiation on the molecule of tetracycline concerning its behavior as complexing and extracting agent; Estudo do efeito da radiacao gama sobre a molecula de tetraciclina relativamente ao seu comportamento como agente complexante e extrator  

Energy Technology Data Exchange (ETDEWEB)

Both solvent extraction and spectrophotometric techniques were used to show the alterations that gamma radiation causes in the behavior of tetracycline molecule as far as its extracting and complexing power are concerned. The effect of gamma radiation on the solid tetracycline molecule, benzyl alcohol and on the solution of both was examined in solvent extraction systems whose aqueous phases were made up by {sup 152} Eu-{sup 154}Eu radioactive tracer solutions and whose organic phases were constituted by tetracycline-benzyl alcohol solutions. Experiments were performed in order to determine whether or not the water used for the pre-saturation of benzyl alcohol would influence the radiolysis of tetracycline. Solvent extraction and spectrophotometry were the techniques used to obtain the necessary data. Absorption spectra of irradiated tetracycline benzyl alcohol solutions submitted to several gamma radiation doses were examined and the alterations shown by these spectra were examined. ...

1982-07-01

4

Determination of volatiles produced during radiation processing in food and medicinal herbs; Determinacao de volateis produzidos durante o processamento por radiacao em ervas alimenticias e medicinais  

Energy Technology Data Exchange (ETDEWEB)

In order to protect food from pathogenic microorganisms as well as to increase its shelf life while keeping sensorial properties (e.g. odor and taste), once the latter are one of the main properties required by spice buyers, it is necessary to analyze volatile formation from irradiation of medicinal and food herbs. The aim of the present study was to analyze volatile formation from Co irradiation of Laurus Cinnamomum, Piper Nigrum, Origanum Vulgare and Myristica Fragans. Possible changes on the odor of these herbs are evaluated by characterizing different radiation doses and effects on sensorial properties in order to allow better application of irradiation technology. l he samples have been irradiated in plastic packages by making use of a {sup 60}Co Gamma irradiator. Irradiation doses of 0, 5, 10, 15, 20 and 25kGy have been tested. For the analysis of the samples, SPME has been applied, while for the analysis of volatile compounds, CG/MS. ...

2008-07-01

6

Dynamics of accumulation and disappearance of cobalt-60 in wheat-soil system  

International Nuclear Information System (INIS)

The dynamics of transportation, accumulation, disappearance and distribution of "6"0Co in the wheat-soil system was studied by using isotope-tracer techniques for simulated pollutants, and the mathematical model of the behavior was established. Rescilts showed that (1) "6"0Co was transported rapidly in the system after the application on soil surface layer. The uptake of "6"0Co by wheat was mainly via root, and redistribution in all parts of wheat occurred consequently. The concentration in root was much higher than that in other parts of wheat plant. The specific activity of "6"0Co in wheat plant rapidly increased to a maximum value, then decreased. The specific activity of "6"0Co in each part of wheat plant was found in the order of root > straw > husk > seed. (2) "6"0Co is mainly detained with in 6cm of soil surface, and specific activity of "6"0Co in soil present a simple exponential declining with depth of soil. (3) The dynamic law can be described as multinomial ...

2008-10-01

8

Mechanisms of cobalt uptake in plants: {sup 60}Co uptake and distribution in Chara  

Energy Technology Data Exchange (ETDEWEB)

The mechanism of cobalt uptake was investigated using cells of the giant alga Chara corallina in which it is possible to resolve separately uptake by the cell wall and actual influx across the cell membrane. The absorption of {sup 60}Co by Chara cells appeared to saturate within 2 h. but this was mainly due to rapid uptake into the cell wall which accounted for 87-92% of the total activity. Even after prolonged desorption most of the cell-associated {sup 60}Co was found on the cell wall. The intracellular distribution of absorbed {sup 60}Co was investigated by fractionating the cell into cytoplasm and vacuole. It was shown that {sup 60}Co influx to the vacuole occurs simultaneously with influx to the cytoplasm. The transported species appears to be Co{sup 2+} rather than the less charged Co(OH){sup +} or Co(O){sub 2}. ...

1998-12-31

9

Mechanisms of cobalt uptake in plants: "6"0Co uptake and distribution in Chara  

International Nuclear Information System (INIS)

The mechanism of cobalt uptake was investigated using cells of the giant alga Chara corallina in which it is possible to resolve separately uptake by the cell wall and actual influx across the cell membrane. The absorption of "6"0Co by Chara cells appeared to saturate within 2 h. but this was mainly due to rapid uptake into the cell wall which accounted for 87-92% of the total activity. Even after prolonged desorption most of the cell-associated "6"0Co was found on the cell wall. The intracellular distribution of absorbed "6"0Co was investigated by fractionating the cell into cytoplasm and vacuole. It was shown that "6"0Co influx to the vacuole occurs simultaneously with influx to the cytoplasm. The transported species appears to be Co"2"+ rather than the less charged Co(OH)"+ or Co(O)_2. "6"0Co influx is pH dependent (optimum pH 7-9), and is sensitive to some other divalent metals. Influx from solutions containing 1 #mu#M "6"0Co was inhibited by 5 #mu#M Cd"2"+, Cu"2"+, and Zn"2"+, but ...

1998-01-01

11

Effect of gamma-rays on spirochaetes of the species Borrelia anserina, Sakharoff, 1891. Part 2. Changes in the antigenic structure  

International Nuclear Information System (INIS)

Bulgarian ... Orig. Title Vliyanie na gama-lychite vyrkhu spirokheti ot vida Borrelia anserina, Sakharoff, 1891. Chast 2. Promeni v antigenniya stroezh.

12

Measurement of spatial dose distribution with thermoluminescence sheet around high dose-rate intracavitary sup 60 Co sources  

Energy Technology Data Exchange (ETDEWEB)

A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL sheet was suggested to provide a convenient means of measuring the ...

1991-06-01

13

Study on the effectiveness of some decontamination agents against skin contamination of {sup 137}Cs and {sup 60}Co  

Energy Technology Data Exchange (ETDEWEB)

In order to evaluate the effectiveness of some decontamination agents against skin contamination of {sup 60}Co and {sup 137}Cs, the experiments were carried out in this study. In the experiments, pig skin was used instead of human skin, {sup 60}CoCl{sub 2} and {sup 137}CsCl were used the liquid sources of skin contamination. To examine the effectiveness of decontamination agents, skin decontamination was tried using soup, EDTA, DAERICON which was developed for decontamination of radionuclides on the surface of building structure, and new decontamination agents such as IOCON, TRICON, and CHARCON, which were developed in this study. The absorption of radionuclides through the skin was evaluated by the gamma-ray detection on the surface of sample skin after radionuclides were penetrated into the skin during 16 hour soiling time. The results of this absorption experiment indicated that 11.5% and 3.2% of ...

1998-03-01

14

Study on the effectiveness of some decontamination agents against skin contamination of "1"3"7Cs and "6"0Co  

International Nuclear Information System (INIS)

In order to evaluate the effectiveness of some decontamination agents against skin contamination of "6"0Co and "1"3"7Cs, the experiments were carried out in this study. In the experiments, pig skin was used instead of human skin, "6"0CoCl_2 and "1"3"7CsCl were used the liquid sources of skin contamination. To examine the effectiveness of decontamination agents, skin decontamination was tried using soup, EDTA, DAERICON which was developed for decontamination of radionuclides on the surface of building structure, and new decontamination agents such as IOCON, TRICON, and CHARCON, which were developed in this study. The absorption of radionuclides through the skin was evaluated by the gamma-ray detection on the surface of sample skin after radionuclides were penetrated into the skin during 16 hour soiling time. The results of this absorption experiment indicated that 11.5% and 3.2% of initial amounts of "1"3"7Cs and "6"0Co, respectively, were penetrated into the skin. In the experiment to ...

1998-03-01

15

Modalidade de morte em mamiferos expostos a irradiacao de corpo inteiro (sindrome aguda da radiacao). (Modes of death in mammals exposed to whole body radiation (acute radiation syndromes)).  

Science.gov (United States)

When an animal is exposed to a sufficient amount of radiation, there will be changes in many organs of the body, and as a result of either the effects in one particular organ or the interaction of effects in several organs, the animal as a whole will show...

1990-01-01

16

Test of electron beam technology on Savannah River Laboratory low-activity aqueous waste for destruction of benzene, benzene derivatives, and bacteria  

Energy Technology Data Exchange (ETDEWEB)

High energy radiation was studied as a means for destroying hazardous organic chemical wastes. Tests were conducted at bench scale with a {sup 60}Co source, and at full scale (387 l/min) with a 1.5 MV electron beam source. Bench scale tests for both benzene and phenol included 32 permutations of water quality factors. For some water qualities, as much as 99.99% of benzene or 90% of phenol were removed by 775 krads of {sup 60}Co irradiation. Full scale testing for destruction of benzene in a simulated waste-water mix showed loss of 97% of benzene following an 800 krad dose and 88% following a 500 krad dose. At these loss rates, approximately 5 Mrad of electron beam irradiation is required to reduce concentrations from 100 g/l to drinking water quality (5 {mu}g/l). Since many waste streams are also inhabited by bacterial populations which may affect filtering operations, the effect of irradiation on those ...

1993-08-01

17

Multistep process of neoplastic transformation of normal human fibroblasts by 60Co gamma rays and Harvey sarcoma viruses  

Energy Technology Data Exchange (ETDEWEB)

As reported previously (Namba et al., 1985), normal human fibroblasts were transformed by 60Co gamma-ray irradiation into immortal cells with abnormal karyotypes. These transformed cells (KMST-6), however, showed a low cloning efficiency in soft agar and no transplantability. However, upon treatment with Harvey murine sarcoma virus (Ha-MSV), the cells acquired elevated clonability in soft agar and transplantability in nude mice. Ha-MSV alone, however, did not convert normal human fibroblasts into either immortal or tumorigenic cells. The Ha-MSV-transformed KMST-6 cells showed an enhanced expression of the ras oncogene, but normal and 60Co gamma-ray-transformed cells did not. Our current data suggest that gamma rays worked against normal human cells as an initiator, giving rise to chromosome aberrations and immortality, and that Ha-MSV, probably through its ras oncogene, played a role in the progression ...

1986-03-15

18

R46 and pKM101 plasmid-mediated resistance to ionizing radiation in Escherichia coli  

International Nuclear Information System (INIS)

The ability of the R46 R factor and its derivative pKM101 to modify sensitivity to "6"0Co #gamma# radiation was studied. In Escherichia coli K12 both plasmids enhanced bacterial survival after "6"0Co #gamma# irradiation. This effect was dependent on recA"+ genotype but not on recB"+, recB"+recC"+, and recF"+ genotypes. 5-Fluorouracil eliminated the R46 R factor from the parent and its rec"- mutant strains. These strains lost not only the antibiotic resistance coded for R46 R factor but their radioresistance as well.

19

Preparation and applications of wood-polyester composites  

International Nuclear Information System (INIS)

Optimum processing parameters were searched for the pilot-scale production of wood-polyester composites by irradiation of resin-impregnated wood material. The radiation initiation of the following systems were examined in wood and without wood matrix: methyl methacrylate, mixture of styrene and acrylonitryle, and their combination with unsaturated polyester. In the most cases the over-all rate of the complete polymerization process in wood matrix is proportional to the square root of the initiation rate. The parameters of the radiation technology of wood-polyester composites have been determined, using 260 TBq (7 kCi) "6"0Co radiation source. A pilot plant has been constructed using an underwater irradiation system of 1.85 PBq (50 kCi) "6"0Co. The successful production rate of 200 kg wood-polyester composite per day, as well as the application tests have demonstrated the technical feasibility of this new structural material. (author).

1982-01-01

20

Optimization of decontamination strategy for CANDU-PHW reactors  

International Nuclear Information System (INIS)

Theoretical models of the decontamination process are developed and combined with an existing model of "6"0Co production in CANDU PHW reactors to predict the effects of decontamination on long term "6"0Co build-up in reactor primary heat transport systems. The effects of decontamination interval, decontamination factor, and post-decontamination corrosion release are calculated. An optimum decontamination strategy for a Pickering G.S. type reactor is developed on the basis of a cost-benefit analysis. This study indicates that the optimum decontamination interval is approximately six years. This optimum interval is relatively insensitive to variations in the costs of personnel exposure, the cost of a decontamination, the decontamination factor, and the post-decontamination corrosion model used. (author).

 
 
 
 
21

Laboratory studies of the diffusive transport of 137Cs and 60Co through potential waste repository soils  

British Library Electronic Table of Contents (United Kingdom)

Tests using reconstituted samples have been performed to assess the diffusive transport of 137Cs and 60Co through natural regolith materials from a region in South Australia being considered for a radioactive waste repository. A double diffusion cell apparatus made of polycarbonate resin was developed to estimate the effective diffusion (De) and sorption coefficients (Kd) that allowed large withdrawals from the source and collector cells and has enabled tests with low concentrations of radioactivity. An alternative to porous stainless steel filter plates has also been used to reduce uncertainty in test interpretation. Analysis of the transient data used a staged method of the Laplace transform to take into consideration the volume of the samples withdrawn from the apparatus during testing....

2010-01-01

22

Albedo method applied to coupled neutron-gamma shielding radiations; Metodo do Albedo aplicado a blindagem de radiacoes neutron-gama acoplados  

Energy Technology Data Exchange (ETDEWEB)

The Albedo Theory was applied in order to develop an one-group algorithm for coupled neutron-gamma shielding calculations. The configuration analyzed consists of multilayered plane systems, where a incident neutron current generates gamma radiation through neutron-gamma reactions. The results obtained by Albedo Method and ANISN code have shown excellent agreement. (author)

2000-07-01

23

Use of gamma radiation for thermoplastics synthesis  

International Nuclear Information System (INIS)

Samples of vynil-benzene and vinyl acetate were irradiated with gamma rays from a sup(60)Co source. Viscosity analysis performed by using the method of Stokes showed an increase in the viscosity of the materials up to the total solidification for increased doses of gamma rays. This result characterized the formation of macromolecules of two thermal plastics, the poly (vinyl-benzene) and the poly (vinyl acetate). (author).

1991-05-27

24

Transfer of 137Cs and 60Co in a waste retention pond with emphasis on aquatic insects  

International Nuclear Information System (INIS)

The objectives of this research were (1) to analyze the transfers of 137Cs and 60Co in a retention pond, with emphasis on aquatic insects and (2) to determine if detectable concentrations of these radionuclides are exported by emerging aquatic insects. We analyzed the radionuclide concentrations in the following components: water solution, bottom sediments, suspended particulate matter, plankton, floating mats of filamentous algae, benthic macroinvertebrates, and emerging aquatic insects. Samples were collected quarterly from June 1981 to April 1982. The lowest concentrations (in picocuries per milliliter) occurred in solution (range: 1.4 X 10(2) to 3.2 X 10(2) for 137Cs and 8.1 X 10(-1) to 2.2 X 10(0) for 60Co). The highest concentrations (in picocuries per gram dry weight) occurred in the sediments (range: 1.5 X 10(4) to 1.1 X 10(8) for 137Cs and 1.0 X 10(2) to 4.3 X 10(6) for ...

25

Radiation treatment of some poultry products  

International Nuclear Information System (INIS)

Practical procedures were developed for large-scale microbial decontamination of dry egg powder and gelatine with gamma radiation ("6"0Co). The formation and lifes of free organic radicals in these materials were examined by ESR measurements of powder samples. The concentration of these radicals was studied in dependence on the time of storage. Secondary oxidation of egg fats by air oxygen was investigated. Sensoric tests of irradiated gelatine, both in powder and hydrogel form, were performed. (author). 4 figs., 2 tabs., 2 refs.

1988-09-26

26

Ionization-chamber-dependent factors for calibration of megavoltage X-ray and electron beam therapy machines  

International Nuclear Information System (INIS)

When exposure-calibrated ionization chambers are used to calibrate megavoltage X-ray and electron beam therapy machines, the calibration factor can be divided into a chamber-dependent and a chamber-independent component. Until recently, only the chamber-independent part, which has been derived theoretically, has been used; the chamber-dependent component has been ignored. Recent experimental and theoretical considerations, however, have indicated that the dependent component must be taken into account and can affect the calibration by as much as 4%. The calibration can change due to (i) the thickness of the chamber wall, (ii) the chamber wall composition, i.e. whether the chamber is constructed of air-equivalent material, or tissue- or water-equivalent material, and (iii) the size of the chamber changing the displacement factor. Theoretical and experimental evidence indicates that the third factor varies from approximately 4.5% for "6"0Co #gamma#-rays to 0.5% for 25 MV X-rays, and that ...

27

Evaluation of a process for the decontamination of radioactive hotspots due to activated stellite particles  

International Nuclear Information System (INIS)

Some of the Indian pressurized heavy water reactors (PHWRs) which use Stellite balls in the ball and screw mechanism of the adjustor rod drive mechanism in the moderator circuit have encountered high radiation fields in the moderator system due to "6"0Co. Release of particulate Stellite is responsible for the hotspots in addition to the general uniform contamination of internal surfaces with "6"0Co. Extensive laboratory studies have shown that it is possible to dissolve these Stellite particles by adopting a three-step redox process with permanganic acid as the oxidizing agent. These investigations with inactive Stellite in powder form helped to optimize the process conditions. Permanganic acid was found to have the highest dissolution efficiency as compared to alkaline and nitric acid permanganate. The susceptibility of Stellite to corrode or dissolve was found to depend on the concentration of the permanganate, pH and temperature of the process and microstructure of the Stellite ...

2011-06-01

28

Analysis of ZPPR experiments supporting production of "6"0Co in FFTF  

International Nuclear Information System (INIS)

An effort to expand the irradiation mission of the Fast Flux Test Facility (FFTF) beyond testing fuels and materials for the liquid-metal reactor (LMR) program included a study of the feasibility of producing commercial quantities of "6"0Co. The "6"0Co would be produced by neutron capture in assemblies containing an array of natural cobalt pins and hydrogen-bearing moderator pins located at the periphery of the FFTF core. Adding hydrogenous material to the assemblies enhances "6"0Co production by slowing neutrons into energy ranges where the "5"9Co capture cross section is higher. Some of the moderated neutrons leak from the moderated region to adjacent fuel regions, increasing local fission rates. In order to validate calculated fission rates and establish calculational biases and uncertainties, experiments were conducted in the zero-power plutonium reactor (ZPPR) to measure fission rates in fuel regions adjacent to a mock-up of a cobalt production assembly. The ZPPR experiment and ...

1987-06-07

29

Analysis of TL glow curves in differently doped LiF:Mg,Ti  

International Nuclear Information System (INIS)

A computerised curve-fitting method was developed to calculate the trapping parameters in LiF TLD-100 and LiF:Mg, Ti. After irradiation in a "6"0Co field and with X rays emitted at different voltages the TL process is best described by first-order kinetics. A dependence of the trapping parameters on both the concentration of Mg and Ti and photon energy was detected. (author).

30

Study of the {sup 60}Co speciation in the aqueous radioactive waste of the la Hague nuclear reprocessing plant; environmental behaviour after discharges in the waters of the channel; Etude de la speciation du {sup 60}Co dans les effluents de l'usine de retraitement de combustibles irradies de la Hague; devenir apres rejet dans les eaux de la Manche  

Energy Technology Data Exchange (ETDEWEB)

{sup 60}Co is produced as an activation product and is present in the low-level aqueous radioactive waste released from the La Hague plant. At present, the concentration in the sea (non filtered at 0.45 {mu}m) at the Goury site are close to or even below, the detection limit: 0.2 mBq.l{sup -1}. The {sup 60}Co speciation depends on the type of effluent considered: in the effluent A ('active'), the cobalt is in the form of a stable trivalent complex; in the effluent V (to be checked), the cobalt is in majority (50% of the activity release) in the form of particles (>0.45 {mu}m), and then in the form of two soluble species: ionic divalent (Co{sup 2+}) and some stable complexes. The evolution of the reprocessing techniques used does not affect the speciation. So, since the nuclear reprocessing plant started at the La Hague plant in 1966, the chemical species discharged in the sea ...

1999-07-01

31

Purification of radioactive decontamination liquids from NPP Paks with reactive adsorption and ion-exchange process  

International Nuclear Information System (INIS)

In nuclear power plant Paks, Hungary, alkaline oxidative (NaOH, KMnO_4, H_2O) and acidic reductive (citric- and oxalic acid, water) liquids are using for the decontamination of primary circuit equipment (main liquid circulating pumps, steam generators, pipelines etc). The above mentioned decontamination liquids are containing "1"1"0"mAg, "9"5Nb, "5"4Mn, "5"8 Co, "6"0Co, "5"1 Cr, "1"2"4 Sb radioisotopes, summarized radioactivity is between 10"3-8x10"4 kBq/dm"3 liquid. The decontamination liquid can be cleaned with reactive adsorption (active carbon) and ion-exchange process at elevated temperature (333-368 K) in multilayered columns. After purification the summarized radioactivity for "5"4Mn, "6"0Co, and "1"1"0"mAg are in the outlet liquid below 1 kBq/dm"3. Decontamination factor DF#approx =#10"3-10"4, volumetric reduction factor VRF#approx =#50-500.

1999-11-04

32

Disturbed tooth formation by /sup 60/Co-gamma-ray radiation  

Energy Technology Data Exchange (ETDEWEB)

The molar of guinea pigs was irradiated with /sup 60/Co-..gamma.. ray for daily observations of the manifestation of disturbed tooth formation by microradiography and the time registration by tetracycline-labelling. Irradiation first injured young blast cells of the dentin in the growth phase, dental pulp cells, and cells of the enamel. The portion composed of injured cells formed a depressed ''constriction'' from the dental pulp side toward the border between the enamel and dentin. The cells of the enamel injured by irradiation in the growth phase later formed a very thin irregular stroma. In contrast, cells in the differentiation or subsequent phase at the time of irradiation and cells probably having started to grow after irradiation proceeded with formation of a normal stroma and calcification. No uniform relation was obtained between the histological staining of the organic stroma of normal or abnormal ...

1982-02-01

33

Body and brain development following exposure to "6"0Co #gamma#-irradiation during pregnancy in mice  

International Nuclear Information System (INIS)

We studied the dose-response effects of #gamma#-irradiation on the weight gains of the body and the brain in ICR mice exposed to various doses of "6"0Co #gamma#-irradiation ranging from 0 to 1.5 Gy on day 13 of pregnancy (E13). We found that 0.5 Gy #gamma#-irradiation caused a significant reduction in brain weight but not in body weight among 6-week-old mice. Higher doses (1.0, 1.5 Gy) seriously inhibited body and brain development, resulting in significantly low weights at 6 weeks of age. A significantly lower brain weight among fetuses exposed to 1.5 Gy was found as early as 24 hours after exposure, while significant reductions in the body weight of these same fetuses appeared 3 days after exposure. The effects of radiation on brain and body development were similar for both males and females. (author).

34

Use of high energy radiation component as a reference source for radiometric testing  

International Nuclear Information System (INIS)

The possibility of providing high accuracy of absorption and albedo methods of radiometric testing due to the use of high-energy radiation component that has passed through a barrier and gone from it in the opposite direction as a reference source, is considered. It is shown that the use of high-energy component of penetrating radiation as a reference source decreases the device response to the main interference in a much larger degree than its response to the change of measured parameter. Experiments are performed using steel pipes and plates. "2"4"1Am, "1"3"7Cs and "6"0Co are used as sources.

35

The kinetics of the CAN-DECON process  

International Nuclear Information System (INIS)

When decontaminated with continuously replenished CAN-DECON reagent in a once-through system, carbon steel contaminated with "6"0Co during exposure to reducing coolant in stainless steel loops loses up to 90 percent of its radioactivity in the first few minutes. Afterwards, the rate of removal falls to much lower values which persist for many hours to the end of the experiment. The effects of flow rate, temperature and reagent concentration on the initial rates of decontamination indicate that mass transfer in the liquid is an important factor in the decontamination. The decontamination factor is influenced by the initial rate.

1982-09-19

36

Si-JFET devices and related noise behavior under irradiation  

Energy Technology Data Exchange (ETDEWEB)

Monolithic N-channel junction field effect transistors (NJFETs) dc characteristics, small signal parameters and noise have been studied from 300 K down to cryogenic temperatures before and after irradiation with {sup 60}Co {gamma}-rays and fast neutrons (1 MeV). Radiation induced effects on dc parameters and noise are reviewed. Noise spectral density measurements performed at various temperatures have shown that the radiation induces a noise increase which is temperature and frequency dependent. (orig.). 14 refs.

1998-02-01

37

Radiation-induced chemical modification of wood  

International Nuclear Information System (INIS)

The results of theoretical and experimental investigations, describing the effect of ionizing radiation on wood and its main components and methods for production of wood-plastic composites by means of radiation-induced chemical modification are generalized. Domestic and foreign experience in their production is systematized; physico-mechanical characteristics of new material, simulation and calculation of irradiating devices, as well as calculation and experimental study of #gamma#-radiation attenuation both by wood material and by wood of different species are given. Gamma sources ("6"0Co isotope, a hot loop of a nuclear reactor) as well as electron accelerators are considered as ionizing radiation sources.

1985-01-01

38

Radiation hardness of plastic scintillating fiber  

International Nuclear Information System (INIS)

We report on measurements of radiation hardness of the plastic scintillating fiber SCSF-81. Fibers were irradiated with "6"0Co #gamma#-rays and fast neutrons up to 105 Gy and up to 5 x 1013 n/cm"2, respectively. Deterioration of the attenuation length of the scintillating fiber was studied. Some significant deterioration was observed at the integrated dose of about 1 x 103 Gy and at the integrated neutron flux (neutron fluence) of about 1 x 1012 n/cm"2 for #gamma#-ray and neutron irradiation, respectively. (author).

39

Primary standardization of {sup 242} Am radioactive sources  

Energy Technology Data Exchange (ETDEWEB)

The procedure followed by the Laboratorio de Metrologia Nuclear in Sao Paulo, Brazil, for the standardization of {sup 242g} Am is described. The calibration system was composed of a 4 {pi} gas-flow proportional counter coupled to a pair of NaI(Tl) crystals operating in coincidence. The samples were produced by irradiating dried aliquots of {sup 241} Am with thermal and epithermal neutrons at the IEA-R1 research reactor. The efficiency tracer technique has been applied using {sup 60} Co as tracer. The beta detection efficiency was changed by external absorbers and extrapolated to unity by linear least square fitting applying covariance methodology. (author)

2001-07-01

40

Preparation of wood-polymer composites by using ionizing radiation  

International Nuclear Information System (INIS)

Radiation-initiated polymerization of styrene and acrylic acid in poplar wood were investigated for the preparation of wood-polymer composites. The direct irradiation method was applied to the monomer adsorbed poplar wood specimens. 8000 Ci "6"0Co source at a dose rate of about 0.4 Mrad/h was used. Furthermore the effects of carbon tetrachloride, methanol, dioxane and acrylonitrile on styrene polymerization were investigated and the reaction rates were calculated for each case. The influence of CCl_4 (10%) on acrylic acid polymerization in poplar wood was also determined. (author).

1982-05-01

 
 
 
 
41

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

Energy Technology Data Exchange (ETDEWEB)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a {sup 60}Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used.

2001-05-01

42

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

International Nuclear Information System (INIS)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used.

2001-05-01

43

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

International Nuclear Information System (INIS)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used. (author)

2002-01-01

44

Effect of urea on the mechanical strength of wood-plastic composites  

Energy Technology Data Exchange (ETDEWEB)

The effect of additives on the grafting of a monomer, butylmethacrylate (BA), into simul (a soft wood) has been studied using {sup 60}Co source at 3 Mrad. The enhancement of polymer loading (grafting) by the addition of minute amounts (1%) of oligomers and of polyfunctional monomers into simul + BA system has been further increased in the presence of acid and urea. The synergistic polymer loading yields by acid addition cause substantial decrease of tensile strength values of wood-plastic composite; but urea increases both polymer loading and tensile strength values synergistically in these systems. (author).

1992-07-01

45

Effect of urea on the mechanical strength of wood-plastic composites  

International Nuclear Information System (INIS)

The effect of additives on the grafting of a monomer, butylmethacrylate (BA), into simul (a soft wood) has been studied using "6"0Co source at 3 Mrad. The enhancement of polymer loading (grafting) by the addition of minute amounts (1%) of oligomers and of polyfunctional monomers into simul + BA system has been further increased in the presence of acid and urea. The synergistic polymer loading yields by acid addition cause substantial decrease of tensile strength values of wood-plastic composite; but urea increases both polymer loading and tensile strength values synergistically in these systems. (author).

1992-01-01

46

CMOS/SOI hardening at 100 MRAD (SiO_2)  

International Nuclear Information System (INIS)

Hardened CMOS/SOI 29101 microprocessor, elementary cells and transistor shave been irradiated at levels between 10 Mrad(SiO_2) and 1 Grad(SiO_2) ("6"0Co and 10 keV x-rays). SIMOX buried oxide behavior in the range of 100 Mrad(SiO_2) and a channel-stopped MOS/SOI structure avoiding lateral leakage current are presented. These two items indicate the feasibility of a CMOS/SOI technology operating in the hundred Mrad(SiO_2) range.

1990-07-16

47

Basic radiation sterilization properties of packaging materials  

International Nuclear Information System (INIS)

The foils of various materials were irradiated with "6"0Co with an activity of 11,538 TBq. The minimum radiation dose was 25 kGy. Changes in chemico-physical properties were evaluated by infrared spectroscopy and were not detected after irradiation with 25 kGy. Packing foils were subjected to the following tests: mechanical tests, tests of weld strength, tests of impact resistance, free fall tests, permeability tests for water vapour and microbiological tests. The results of all tests were tabulated. The tests showed that the foils are impermeable for microorganisms and provided the welds are airtight the packed products remain sterile. (J.P.).

1984-11-28

48

High dose rate /sup 60/Co remote afterloading irradiation in cancer of the cervix in Haiti, 1977-1984  

Energy Technology Data Exchange (ETDEWEB)

From 1977 through 1984, 293 previously untreated patients with biopsy proven carcinoma of the uterine cervix were treated by whole pelvis irradiation and high intensity 60Co remote afterloading (RAL) intrauterine tandem techniques in Haiti. The treatment results were analyzed retrospectively to evaluate the therapeutic results and prognostic factors of a strict protocol involving 40 Gy to the whole pelvis (2 Gy/day, 5 days/week). In addition, on the 5th day of the 3rd week, the first outpatient 60Co remote afterloading intracavitary insertion, delivering 7.5 Gy to point A with each insertion, repeated 3 times by a week separation for a total of 4 times. The total TDF for external beam plus RAL was 158 and 175 for early and late effects respectively. One hundred-four patients were evaluable after 1 year or more follow-up, with a median of 26.5 months. No evidence of disease (NED) by Stage at 1 year was: ...

1988-06-01

49

Fusion of protoplasts with irradiated micro protoplasts as a tool for radiation hybrid panel in citrus;Fusao de protoplastos com microprotoplastos irradiados como ferramenta para painel hibrido de radiacao em citros  

Energy Technology Data Exchange (ETDEWEB)

The objective of this work was to combine asymmetric somatic hybridization (donor-recipient fusion or gamma fusion) to microprotoplast-mediated chromosome transfer, as a tool to be used for chromosome mapping in Citrus. Swinglea glutinosa micro protoplasts were irradiated either with 50, 70, 100 or 200 gamma rays and fused to cv. Ruby Red grapefruit or Murcott tangor protoplasts. Cell colonies were successfully formed and AFLP analyses confirmed presence of S. glutinosa in both 'Murcott' tangor and 'Ruby Red' grapefruit genomes. (author)

2009-12-15

50

Production of plastified wood with stronger static bending strength means of polymerization induced by gamma radiation; Producao da madeira plastificada de elevada resistencia a flexao estatica mediante polimerizacao induzida por raios gama  

Energy Technology Data Exchange (ETDEWEB)

The use of gamma radiation to obtain wood-polymer composites is one of the applications of radiation that presents the most commercial interest. The process, denominated radiopolymerization, comprises the impregnation of monomers into the completely dried wood followed by exposure to gamma radiation to induce polymerization of the impregnated monomers. I this context, the present work aimed the application of this process to seven kinds of wood existing in the brazilian forests. The considered monomer is styrene and the gamma source is Cobalt-60. The obtained wood-polystyrene composites were found to have stronger static bending strength. (author)

1999-07-01

51

Gamma-ray spectrometric analysis of nuclides formed in thorium by neutron irradiation  

International Nuclear Information System (INIS)

Gamma-ray spectrometric analysis was employed to determine the nuclides formed in thorium by neutron irradiation. Thorium sample was irradiated by neutron from a pure thermal neutron field, neutron field of Cd ratio of about 4, and epithermal neutron field, respectively. The former irradiation was carried out in a thermal neutron column provided for medical uses of neutrons, and the latters were done in the F-ring position of TRIGA II research reactor of Musashi Institute of Technology. The gamma-ray spectra were obtained and analyzed by employing a fully automatic gamma-ray analysis system named ''GAMA: giant frog:-SYSTEM'' developped by Musashi Institute of Technology. The formation of Pa-233 (U-233) was discussed quantitatively with respect to the difference of the neutron field. (author).

1985-02-01

52

Modelling the reworking effects of bioturbation on the incorporation of radionuclides into the sediment column: implications for the fate of particle-reactive radionuclides in Irish Sea sediments  

Energy Technology Data Exchange (ETDEWEB)

A microcosm laboratory experiment was conducted to determine the impact of biological reworking by the ragworm Nereis diversicolor on the redistribution of particle-bound radionuclides deposited at the sediment-water interface. Over the course of the 40-day experiment, as much as 35% of a {sup 137}Cs-labelled particulate tracer deposited on the sediment surface was redistributed to depths of up to 11 cm by the polychaete. Three different reworking models were employed to model the profiles and quantify the biodiffusion and biotransport coefficients: a gallery-diffuser model, a continuous sub-surface egestion model and a biodiffusion model. Although the biodiffusion coefficients obtained for each model were quite similar, the continuous sub-surface egestion model provided the best fit to the data. The average biodiffusion coefficient, at 1.8 {+-} 0.9 cm{sup 2} y{sup -1}, is in good agreement with the values quoted by other workers on the bioturbation effects of this polychaete species. ...

2010-11-15

53

Modelling the reworking effects of bioturbation on the incorporation of radionuclides into the sediment column: implications for the fate of particle-reactive radionuclides in Irish Sea sediments  

International Nuclear Information System (INIS)

A microcosm laboratory experiment was conducted to determine the impact of biological reworking by the ragworm Nereis diversicolor on the redistribution of particle-bound radionuclides deposited at the sediment-water interface. Over the course of the 40-day experiment, as much as 35% of a "1"3"7Cs-labelled particulate tracer deposited on the sediment surface was redistributed to depths of up to 11 cm by the polychaete. Three different reworking models were employed to model the profiles and quantify the biodiffusion and biotransport coefficients: a gallery-diffuser model, a continuous sub-surface egestion model and a biodiffusion model. Although the biodiffusion coefficients obtained for each model were quite similar, the continuous sub-surface egestion model provided the best fit to the data. The average biodiffusion coefficient, at 1.8 #+-# 0.9 cm"2 y"-"1, is in good agreement with the values quoted by other workers on the bioturbation effects of this polychaete species. The ...

2010-11-01

54

Wood-polymer composites. Polymerization of methyl-metacrylate in Pinus strobus var. chiapensis wood by gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

To obtain Pinus wood-plastic composites, wood samples were impregnated with methyl methacrylate and polymerized by the use of gamma rays from a /sup 60/Co at different dose exposure and total dose. The best percentage of polymerization was obtained with the exposure of 2.0 MR of gamma radiation. It was found that the impregnation and polymerization, determined by the density values along the samples were uniform. The density became 2.6 times higher in relation to the control samples. The storage of the impregnated wood samples showed losses of the monomer, even when wrapped with aluminum or polyethylene film. It is recommended that the wood samples should be irradiated soon after impregnation.

1984-12-01

55

Tracking failure of gamma-ray irradiated polybutylene polymers under magnetic field  

British Library Electronic Table of Contents (United Kingdom)

Polymer insulating materials used in radioactive environments are subjected to a risk of surface degradation caused by tracking. The tracking behavior becomes more complex with the presence of magnetic field. This paper presents investigation of tracking failure of gamma-ray irradiated polybutylene naphthalate (PBN) and polybutylene terephthalate (PBT) under magnetic field. The samples were irradiated in air up to 100 kGy and then up to 1000 kGy with dose rate of 10 kGy/h by using a 60Co gamma-source. Magnetic field Formula Not Shown with flux density of 250 mT was assembled perpendicularly to electric field Formula Not Shown , which gave rise to relative angle between Formula Not Shown and surface normal vector Formula Not Shown of 0degree, 90degree and 180degree, respectively. The experi...

2011-01-01

56

Study on prepartion of polyethylene ion-exchange capillary by radiation induced graft co-polymerization  

International Nuclear Information System (INIS)

The synthetic process of polyethylene cation exchange capillary via radiation grafting polystyrene by simultaneous irradiation with "6"0Co #gamma#-ray source and sulfonation with concentrated H_2SO_4 was studied. The effects of dose, dose rate, monomer concentration, solvents, temperature and crosslinking agents on the graft copolymerization of styrene with polyethylene capillary were illustrated. The relationship between the radiation grafting conditions and the properties of ion-exchange capillary were examined. A polyethylene cation exchange capillary with I.D. 0.8 mm, length 20 m, exchange capacity 0.7 Meq/g 60% capacity in 10 s (flow rate 20 ml/min) was prepared. No significant loss of copacity was found from this ion-exchange capillary after 200 adsorption/regeneration cycles.

57

Role of additives in wood plastic composite of water soluble monomer  

International Nuclear Information System (INIS)

Wood plastic composites are prepared under radiation of "6"0Co gamma source with simul, a low grade wood of Bangladesh using a water soluble monomer acrylamide (AM) mixed with a swelling solvent methanol, water or methanol/water (1:1) at different compositions in the presence of a number of additives and co-additives such as NVP (N-vinylpyrrolidone), TPGDA (tripropylene glycol diacrylate), TMPTA (trimethylol propane triacrylate), sulfuric acid, urea and copper sulfate. Polymer loading (PL) and tensile strength (TS) of the composites are measured. The role of these additives on the composites is also discussed. It is observed that nitrogen-atom containing-materials like urea, NVP and AM produce composites with the highest mechanical strength, and incorporation of copper into this system provides additional property of protection and preservation of the composites against attacks by insects and microbes. (author).

1994-01-01

58

Radioactivity decontamination efficiency of ceramic filter in an incineration volume reduction system of radioactive waste  

Energy Technology Data Exchange (ETDEWEB)

The small pilot facility of a cyclone type suspension incineration system of radioactive waste was set up in order to evaluate the decontamination efficiency of a high efficiency ceramic filter. The evaluation was made by use of /sup 54/Mn, /sup 59/Fe, /sup 60/Co, /sup 65/Zn and /sup 137/Cs. 1. The decontamination factor by one line of ceramic filter for every species were over 10/sup 5/. 2. The decontamination factor increased by one oder when water vapor exists in off-gas. The same tendency was also observed when iron dioxide existed at the incineration of cation exchange resin.

1987-02-01

59

Radioactivity decontamination efficiency of ceramic filter in an incineration volume reduction system of radioactive waste  

International Nuclear Information System (INIS)

The small pilot facility of a cyclone type suspension incineration system of radioactive waste was set up in order to evaluate the decontamination efficiency of a high efficiency ceramic filter. The evaluation was made by use of "5"4Mn, "5"9Fe, "6"0Co, "6"5Zn and "1"3"7Cs. 1. The decontamination factor by one line of ceramic filter for every species were over 10"5. 2. The decontamination factor increased by one oder when water vapor exists in off-gas. The same tendency was also observed when iron dioxide existed at the incineration of cation exchange resin. (author).

60

Radiation technology, radiation technics and technological dosimetry in the Institute of Isotopes of the Hungarian Academy of Sciences. 1966-1981  

Energy Technology Data Exchange (ETDEWEB)

Pilot-plant irradiation began in Hungary in 1969 with the construction of a high-activity multi-purpose /sup 60/Co facility. Technologies for radiation sterilization, food handling, plastics irradiation as well as chemical dosimetry, semiconductor instrumental dosimetry, computer-based construction and control methods have been developed. Our chlorobenzene dose-meter system is used in Hungary and abroad; as a result of an IAEA-organized dosimetric intercomparison the system was adopted as a reference system. The institute has developed into a basic institute for the reconstruction and re-load of old ..gamma..-facilities as well as it serves for the planning, construction and launching of new ones in Hungary.

1982-01-01

 
 
 
 
61

One-electron reduction of chloroperoxidase by radiolytically generated electrons  

Energy Technology Data Exchange (ETDEWEB)

Upon irradiation of aqueous ethylene glycol/water solutions of native chloroperoxidase (CPO) with {sup 60}Co-gamma rays at 77K one observes the one-electron reduction of the enzyme active site by radiolytically generated thermolyzed electrons. In the present study the first absorption spectrum of a low-spin ferrous form of CPO is reported which has peaks at 438, 532 and 563 nm, similar to those observed previously for cytochrome P-450. All previously described ferrous forms of CPO are high spin. In order to observe the final results of the CPO reaction with electrons, the spectral changes of native enzyme after room temperature-gamma-irradiation have also been investigated. Evidence of changes is also presented probably connected with disruption of the tertiary structure of enzyme, correlated with decrease of enzyme activity.

1990-05-16

62

One-electron reduction of chloroperoxidase by radiolytically generated electrons  

International Nuclear Information System (INIS)

Upon irradiation of aqueous ethylene glycol/water solutions of native chloroperoxidase (CPO) with "6"0Co-gamma rays at 77K one observes the one-electron reduction of the enzyme active site by radiolytically generated thermolyzed electrons. In the present study the first absorption spectrum of a low-spin ferrous form of CPO is reported which has peaks at 438, 532 and 563 nm, similar to those observed previously for cytochrome P-450. All previously described ferrous forms of CPO are high spin. In order to observe the final results of the CPO reaction with electrons, the spectral changes of native enzyme after room temperature-gamma-irradiation have also been investigated. Evidence of changes is also presented probably connected with disruption of the tertiary structure of enzyme, correlated with decrease of enzyme activity.

1990-05-01

63

Low-temperature radiation polymerization of triethylene glycol. cap alpha. ,. omega. -dimethacrylate. [Gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

Kinetics of postradiation polymerization of triethylene glycol ..cap alpha.., ..omega..-dimethacrylate has been studied by calorimetric method. The low-temperature radiolysis has been studied by ESR method. The radiation-chemical yield of radicals on ..gamma..-irradiation by /sup 60/Co is determined being equal to 6+-1 1/100 ev. Transformation of the radicals spectrum into the spectrum of propagating macroradicals proceeds at 140 K. After the transition from glassy to liquid state (Tsub(g)=193 K) the intensive postpolymerization begins. During the polymerization the disappearance of radicals is observed. For the low-temperature region the effective activation energy of polymerization is determined beina equal to 50.7+-0.8 kJ/mol.

1984-04-01

64

Improving protein quality of soybean through induced mutations  

International Nuclear Information System (INIS)

Soybean is one of the most economical and nutritious food packed with basic nutrients that combat diseases stemming from mal- and under-nutrition. Despite its rich nutritional profile, use of soybean in food has been limited because soybean proteins are often associated with compounds, which could exert a negative impact on the nutritional quality of the protein. Trypsin inhibitor (TI) is one of the important anti-nutritional factors that exert negative effect by causing growth inhibition. Soybean cultivar VLS-2 was irradiated with 250 Gy gamma rays in a gamma cell (200) with 60Co source installed at BARC to induce mutations for low trypsin inhibitor content. Three mutants with lower levels of TI content were identified and can be utilized for developing elite varieties of soybean. (author)

2011-02-22

65

Effect of radiation on certain animal viruses in liquid swine manure  

International Nuclear Information System (INIS)

The virucidal effect of _6_0Co gamma radiation was studied in cell culture medium and in liquid swine manure involving the most important porcine viruses that can be spread by liquid manure. The radiation doses (20 kGy and 30 kGy) were determined in preliminary experiments employing a porcine enterovirus from the serogroup 1 (Teschen group). In the main experiment, the following viruses were employed: swine vesicular disease (SVD) virus, type C foot-and-mouth disease (FMD) virus, a field strain of Aujeszky's disease (AD) virus, transmissible gastroenteritis (TGE) virus, as well as bovine viral diarrhoea (BVD) virus. The latter strain served as a model for hog cholera virus. The results of the experiments indicate that safe disinfection of the virus infected liquid swine manure by ionizing radiation requires a radiation dose of 30 kGy. (author).

1983-01-01

66

Comparative evolution of various CCD image sensors hardening techniques with ionizing radiation  

International Nuclear Information System (INIS)

This paper reviews various techniques to harden Charged Coupled Device (CCD) sensors and the results after irradiation of three Thomson n buried channel CCDs having a different degree of hardening. It describes the major irradiation effects on CCD performances and it makes a comparison of the results between the different hardening levels. It shows good results on dark voltage after ionizing radiation for TH 7863M device hardened both by design and by operating conditions (MPP mode) with respect to the standard device TH 7863A. The irradiations were performed with "6"0Co or X-ray (10 keV) sources on devices in operating mode. (author). 3 refs., 8 figs.

67

The effect of perinatal "6"0Co gamma radiation on brain weight in beagles  

International Nuclear Information System (INIS)

Beagle dogs were given single, whole-body "6"0Co gamma-radiation exposures at one of three prenatal (8, 28, or 55 days postcoitus) or three postnatal (2, 70, or 365 days postpartum) ages to evaluate the relative radiosensitivity of various stages of brain development. A total of 387 dogs received mean doses ranging from 0.16 to 3.83 Gy, and 120 dogs were sham-irradiated. Groups of dogs were sacrificed at preselected times from 70 days to 11 years of age. Brain weight decreased significantly with increasing dose in dogs irradiated at 28 or 55 days postcoitus or at 2 days postpartum. Irradiations at 28 days postcoitus were dramatically more effective in causing a reduction in brain weight than those at 55 days postcoitus or 2 days postpartum. Among dogs given 1.0 Gy or more and followed for up to 4 years, there was a radiation effect evident at all three sensitive exposure ages. Among dogs given lower doses and followed for up to 11 years, there was a significant decrease in brain weight ...

68

Monte Carlo-based investigation of effect of inhomogeneity in brachytherapy dose calculation - Part I  

International Nuclear Information System (INIS)

Brachytherapy refers to short distance treatment of cancer with radiation from small, encapsulated radionuclide sources. This type of treatment is given by placing sources directly into or near the volume to be treated. The dose is then delivered continuously, either over a short period of time (temporary implants) or over the lifetime of the source to a complete decay (permanent implants). This technique is extensively used in the treatments of gynecological, breast, prostate, head and neck, and other soft tissue cancers. The clinical outcomes of this treatment depend on accurate dosimetry and dose delivery. The patient is generally considered to be water equivalent. So the treatment planning system software generally is based on measured or calculated dose distributions in homogenous water medium. In real situation, the treatment volume is not homogenous water medium, but it is a heterogeneous medium consisting of bone, soft tissue, lung, air etc. For better understanding we present ...

2009-04-01

69

Impact assessment using 25 years of environmental radioactivity monitoring data at Tarapur Maharashtra site  

International Nuclear Information System (INIS)

Environmental Survey Laboratory at Tarapur, Maharashtra site carries out environmental radioactivity measurements in different matrices to evaluate the impact of operating nuclear installations. In this paper, the evaluation of data of 1983-2007 (25 years) is presented. Time trends of particulate radioactivity, correlation between "1"3"7Cs in discharge canal seawater and station discharged activity and correlation of "1"3"7Cs, "6"0Co, and "1"3"1I in marine species like Sponge and Nerita and corresponding discharged activity were carried out. Statistical analysis of environmental data of seawater and marine fish for several radionuclides, for distributions, showed that the data best fits lognormal distribution. A strong correlation between "1"3"7Cs in seawater and "1"3"7Cs in liquid waste discharge was observed (R"2 = 0.8, P = 0.000). Similarly correlation was very good for Nerita and discharged concentration for "1"3"7Cs, "1"3"1I and "6"0Co (R"2 = 0.55 to 0.73 and P = 0.000). The ...

2008-07-16

70

Absolute detection efficiency of radiation detecting system for gamma-ray from sources with high activity  

Energy Technology Data Exchange (ETDEWEB)

In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the {sup 137}Cs-source with 10.4 GBq and {sup 60}Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form {sup 137} Cs 1173.23 and 1332.51 keV{sup 60} Co sources, and 14 peaks of {sup 134}Cs and {sup 154}Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that the detection ...

2003-10-01

71

Absolute detection efficiency of radiation detecting system for gamma-ray from sources with high activity  

International Nuclear Information System (INIS)

In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the "1"3"7Cs-source with 10.4 GBq and "6"0Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form "1"3"7 Cs 1173.23 and 1332.51 keV"6"0 Co sources, and 14 peaks of "1"3"4Cs and "1"5"4Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that the detection efficiency of gamma scanning system for 1 MeV gamma-ray is 2.82217x10"-"6 % for the C3 collimator system and ...

2003-10-01

72

Systematic review and gamma radiosensitivity of medicinal plants: development of protocol for quality control; Revisao sistematica e radiossensitividade gama de plantas medicinais: desenvolvimento de protocolo para controle de qualidade  

Energy Technology Data Exchange (ETDEWEB)

The present study discusses the contribution of the adoption of more rigorous and objective criteria to the selection and analysis of information sources, leading to more scientific rigour when registering phytotherapic drugs. To this end, it is herein proposed the adoption of a previously tested and acknowledged methodology, namely the Systematic Revision, as a standard for phytotherapic drug analyses. In order to show differences brought about by the Systematic Revision during the registration procedures of phytotherapic drugs, the case of the Maytenus ilicifolia (known popularly in Brazil as 'espinheira-santa') is presented. As it is well known, the use of ionizing radiation is expanding, especially in medicine and pharmacy. Therefore, gamma radiation was applied to the microbiological quality control of phytotherapic matrices. Results indicated a positive contribution of Systematic Revision to the registration procedures of phytotherapic drugs, as well as the ...

2006-07-01

73

{gamma}-Irradiation-induced preparation of Ag and Au nanoparticles and their characterizations  

Energy Technology Data Exchange (ETDEWEB)

Using {gamma}-irradiation-induced reduction in the field of a {sup 60}Co {gamma}-ray source, colloidal silver and gold nanoparticles were prepared from their corresponding metal salts in aqueous solution and compared with those by chemical reduction. The radiation-based method provided silver nanoparticles with higher concentration and narrower size distribution than those obtained by chemical reduction method while there was no significant difference between the two strategies for the preparation of gold nanoparticles. {gamma}-Irradiation of 1.0 x 10{sup -3} M AgNO{sub 3} solution resulted in nearly 100 times more highly concentrated silver colloids than those by citrate reduction. Furthermore, the radiation method could lead to more highly concentrated silver colloids by simply increasing the concentration of AgNO{sub 3} solution up to 2.0 x 10{sup -2} M. The two metal nanoparticles prepared by the two different methods were characterized by ...

2007-10-15

74

Spectral energy effects in ESR bone dosimetry: photons and electrons  

International Nuclear Information System (INIS)

The spectral energy-dependence of the radiation-induced ESR signal has been studied in ovine cortical bone. Crushed bone samples were irradiated using photon beams with effective energies in the range from 0.06 to 6 MeV, and electron beams with mean energies in the range from 2 to 10 MeV. The photon and electron data were normalized to a dose to bone of 50 Gy and the results are reported as response relative to the ESR signal for photon irradiation at 1.25 MeV ("6"0Co). The photon irradiation results show that the ESR response is greatest at low energies with a relative value of 1.2 at 0.06 MeV. The relative response decreases, as the energy increases, to approximately 0.85 in the region of 2 to 3 MeV. These variations in the relative ESR responses are significantly less than the ESR energy-dependent responses reported in the literature for human tooth enamel and synthetic hydroxyapatite. An explanation for this difference is offered. For electron beam irradiations, the ESR signal is ...

75

Shellfish depuration by gamma irradiation: Final report for the period October 1, 1985-September 30, 1986  

International Nuclear Information System (INIS)

Irradiation of live bivalve molluscs is a promising new technique to reduce the public health threats of viral and bacterial pathogens in the consumption of raw shellfish. In studies conducted within the past year, live hardshelled clams and oysters were innoculated with Simian Rotavirus SA-11, Poliovirus I, and Hepatitis-A virus and treated with gamma ray ionizing radiation from University of Lowell/DOE 800,000 Curie "6"0Co source over a dose range of 0.5--10 kiloGray (50--1000 kilorad) to determine the effectiveness of the process in eliminating viral activity and thus easing the potential viral health threats associated with uncooked bivalves. Two viral strains, SA-11 and Poliovirus I, were employed as models to perfect laboratory technique and to estimate the most appropriate range of dose exposures necessary for optimal inactivation of the infectious pathogen, Hepatitis A. Post-irradiation survivorship of the oysters and quahogs was assessed over a range of exposures, and showed ...

76

Sensorial effects of gamma radiation processing on cinnamon (Laurus cinnamomum) and nut meg (Myristica fragans)  

Energy Technology Data Exchange (ETDEWEB)

Food irradiation is the processing of food products by ionizing radiation in order, among other things, to control food borne pathogens, reduce microbial load and insect infestation, inhibit the germination of root crops, and extend the durable life of perishable products. Irradiation of dried food ingredients, particularly herbs and spices, has a great application potential, and has already been implemented in many countries. Spice irradiation is performed to increase the hygienic quality and used as decontamination processes instead of fumigation methods. European Community approves irradiation processing as an effective residue-free alternative. The present paper evaluates the effect of ionizing radiation on sensorial properties of cinnamon (Laurus cinnamomum) and nut meg (Myristica fragans). The samples have been irradiated in multipurpose irradiator of {sup 60}Co in the doses: 0, 5, 10, 15, 20 e 25 kGy. (author)

2007-07-01

77

Recurrent plot analysis of discharge sequences in tracking test of polybutylene polymers  

Energy Technology Data Exchange (ETDEWEB)

Polymers are required to use in radiation environments as insulation materials. However, they often suffer from tracking failure. There is an increasing demand to evaluate radiation effects on dielectric performance. This paper presents a recurrence plot (RP) approach to analyse surface discharge sequences of gamma-ray irradiated polymer materials based on tracking test. Studying the non-linear characteristics of discharge sequences can assist in understanding the underlying mechanism of the discharge process. Discharge sequences of the test are extended to m-dimensional phase space by using the phase space reconstructed method. As test samples, polybutylene terephthalate (PBT) and polybutylene naphthalate (PBN) were irradiated to 100 kGy and then up to 1 MGy with a dosage rate of 10 kGy h{sup -1} by using a {sup 60}Co gamma source. The tracking tests were carried out according to the test method described in IEC60112. It is found that the RPs ...

2008-10-07

78

Radionuclide adsorption characteristics around coastal water  

Energy Technology Data Exchange (ETDEWEB)

The adsorption capacity of radionuclides onto suspended sediment was experimented on each of the coastal seawater sampled around the Kori and the Wolsung nuclear power plant. During the experiment the quantity and size fraction of suspended sediment were adjusted and the seawater and sediment chemistry is approximated to the expected field condition. Because the sorption capacity depends on the specific minerals, ocean chemistry and radionuclide involved, it is necessary to analyze sediment mineralogy. Clay mineral is dominant in seabed mineral and suspended sediment as the result of x-ray diffraction. Radionuclide sorbed to silty-clay mineral can be rather transported to ocean than scavenged to seabed because of low quantity and fine grained suspended sediment in the coast around the Kori and the Wolsung. The result of adsorption examinations shows that {sup 139}Ce and {sup 51}Cr and {sup 110m}Ag are strongly sorbed to suspended particle, while {sup 137}Cs is less sorbed and {sup ...

1999-07-01

79

Radionuclide adsorption characteristics around coastal water  

International Nuclear Information System (INIS)

The adsorption capacity of radionuclides onto suspended sediment was experimented on each of the coastal seawater sampled around the Kori and the Wolsung nuclear power plant. During the experiment the quantity and size fraction of suspended sediment were adjusted and the seawater and sediment chemistry is approximated to the expected field condition. Because the sorption capacity depends on the specific minerals, ocean chemistry and radionuclide involved, it is necessary to analyze sediment mineralogy. Clay mineral is dominant in seabed mineral and suspended sediment as the result of x-ray diffraction. Radionuclide sorbed to silty-clay mineral can be rather transported to ocean than scavenged to seabed because of low quantity and fine grained suspended sediment in the coast around the Kori and the Wolsung. The result of adsorption examinations shows that "1"3"9Ce and "5"1Cr and "1"1"0"mAg are strongly sorbed to suspended particle, while "1"3"7Cs is less sorbed and "6"0Co uptake is ...

1999-11-04

80

Radiation hardness of plastic scintillating fiber against fast neutron and #gamma#-ray irradiation  

International Nuclear Information System (INIS)

In future collider experiments, where a background radiation level is estimated to be very high, e.g. around 10"2 #approx# 10"5 Gy/yr and 10"1"1 #approx# 10"1"4 n/cm"2/yr at SSC, the detectors operating around the collision point in the experiments will encounter a considerable amount of radiation. Therefore, the detectors, especially the calorimeter, are required to be resistive against high radiation levels. From this point of view, it is of great importance to study the effects of radiation damage on the performance of the detectors. The authors report preliminary results of measurements of radiation hardness of the plastic scintillating fiber Kuraray SCSF-81 against irradiation with fast neutrons and "6"0Co #gamma#-rays in the region of the neutron fluence from 1 x 10"1"1 to 5 x 10"1"3 n/cm"2 and the integrated #gamma#-ray dose from 890 to 10"5 Gy, respectively. Deterioration of both intrinsic light yield and light transmittance of the SCSF-81 has been studied.

1992-10-25

 
 
 
 
81

RBE and OER measurements on the p(66)+Be neutron beam at Faure, South Africa  

International Nuclear Information System (INIS)

Results reported are for single dose exposures and refer to "6"0Co-#gamma#-irradiation. The RBE determined by V79 cell survival and based on the Do ratio was found to be 1.70#+-#0.4 ranging from 1.5 to 1.8. In the case of the regeneration of mouse jejunal crypts the RBE was calculated at ten cell curvival and was found to be 1.68. The maximum acute mouse skin reaction at a skin score of 2.0 was found to be 2.1 while the average skin reaction was 1.7. Growth retardation of Vicia faba bean roots measured at the level of 50% indicated an average RBE of 3.0 and a range of 2.7 to 3.7. The OER obtained for V79 cell survival was found to be 1.7 to 1.8. Comparison is made with the RBE and OER measurements for the neutron facilities at Clatterbridge, Fermilab and Louvain-la-Neuve which produce neutrons by the same nuclear reaction and whose physical specifications closely resemeble those of the Faure neutrons. This comparison indicates that the Faure beam shows no unusual biological features ...

82

Performance testing of selected types of electronic personal dosimeters used in Sudan  

International Nuclear Information System (INIS)

Measurements were carried out for calibration and performance testing of a set of 10 electronic personal dosimeters (EPDs) at the Secondary Standard Dosimetry Laboratory of Sudan. Calibrations were carried out at three X-ray beam qualities described in ISO standard 4037 in addition to 137Cs and 60Co gamma ray beams. The experimental was performed with EPDs mounted on ICRU Slab phantom. X-ray and ?-ray beams were characterized in terms of air kerma free-in-air which were converted to the known delivered personal dose equivalent, Hp(10) using appropriate the air kerma to personal dose equivalent conversion coefficients. Dosimeters tested showed excellent energy and angular response and relative error of indication within the recommended limit for photon energies from 65 keV to 1.25 MeV. The study showed encouraging results for using electronic dosimeters in personal dosimetry.

2010-12-01

83

Mechanism of ageing in irradiated polymers  

Energy Technology Data Exchange (ETDEWEB)

Samples of ultra-high molecular weight polyethylene (UHMWPE) and nylon 66, of grades suitable for use in medical prostheses, were subjected to irradiation using a /sup 60/Co source. The effects of a 10 Mrad dose on percentage crystallinity, tensile behaviour and dynamic mechanical response were established 3 days after irradiation at intervals over a one year period. Crystallinity in UHMWPE was found to increase progressively during this period with consequent changes in mechanical behaviour. It is proposed that the observed ageing process arises from the breakdown of metastable groups in the polymer, which are formed on irradiation, with consequent release of long inter-lamella tie chains. This removes an inhibition to crystal perfection processes, which can occur at room temperature in polyethylene. Infra-red spectroscopic evidence supports the proposal that the metastable species is peroxy or hydroperoxy and that this decomposes on ageing to ...

1988-01-01

84

Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization  

Energy Technology Data Exchange (ETDEWEB)

The measurements of the K X-ray intensity ratio I(K{alpha} {sub 2}/K{alpha} {sub 1}), I(K{beta} {sub 1}/K{alpha} {sub 1}) and I(K{beta}/K{alpha}) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a {sup 241}Am and 123.6 keV {gamma}-rays from a {sup 60}Co were used, and following the radioactive decay of {sup 51}Cr, {sup 55}Fe, {sup 67}Ga, {sup 99}Tc, {sup 111}In, {sup 131}I, {sup 133}Ba, {sup 133}Xe, {sup 137}Cs, {sup 201}Tl and {sup 226}Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.

2007-01-15

85

Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization  

International Nuclear Information System (INIS)

The measurements of the K X-ray intensity ratio I(K#alpha# _2/K#alpha# _1), I(K#beta# _1/K#alpha# _1) and I(K#beta#/K#alpha#) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV #gamma#-rays from a "2"4"1Am and 123.6 keV #gamma#-rays from a "6"0Co were used, and following the radioactive decay of "5"1Cr, "5"5Fe, "6"7Ga, "9"9Tc, "1"1"1In, "1"3"1I, "1"3"3Ba, "1"3"3Xe, "1"3"7Cs, "2"0"1Tl and "2"2"6Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.

2007-01-01

86

Improvement of wood quality used in Syria by irradiation polymerization  

International Nuclear Information System (INIS)

Wood plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, and with Okoume (aucoumea klaineana pierre) imported to Syria in large quantities. Three monomer systems; acrylamide, butylmethacrylate, and styrene were used. polymerization was induced at various radiation doses (10, 20, and 30 kGy) to study the role of radiation doses using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength or tensile strength of the obtained wood polymer composites (WPC) were studied. The effect of the additives, sulfuric acid (H"+), N-vinyl pyrrolidone (NVP), trimethyolpropane triacrylate (TMPTA), urea (U), lithium nitrate (LiNo_3), copper sulfate (CuSO_4) and co-additives on monomer system polymerization were also investigated. Methanol, water and water/methanol mixtures were used as the swelling agents. In general, the use of additives and co-additives brought about an enhancement of tensile strength or ...

2010-04-01

87

INTRINSIC DOSIMETRY: A POTENTIAL NEW TOOL FOR NUCLEAR FORENSICS INVESTIGATIONS  

International Nuclear Information System (INIS)

Thermoluminescence (TL) dosimetry was used to measure dose effects on the raw stock material of borosilicate container glass from different geographical locations. Effects were studied at times up to 60 days post-irradiation at doses from 0.15 to 20 Gy. The minimum detectable dose using this technique was estimated to be 0.15 Gy which is roughly equivalent to a 24 hr irradiation 1 cm from a 50 ng source of 60Co. Two peaks were identified in the TL glow curve, a relatively unstable peak around 125 C and a more stable peak around 225 C. Differences in TL glow curve shape and intensity were also observed for the glasses from different geographical origins. We investigate radiation induced defects in glass to further develop the technique of intrinsic dosimetry - the measurement of the total absorbed dose received by the walls of a container holding radioactive material. Intrinsic dosimetry is intended to be used as an interrogation tool to provide ...

2010-07-11

88

Evaluation of value for hydrogen release from high-level liquid waste. 4. Hydrogen release rate for {gamma}-ray radiolysis of simulated purex waste solutions  

Energy Technology Data Exchange (ETDEWEB)

The rates of hydrogen release from simulated high-level liquid waste (SHLLW) during irradiation of {sup 60}Co {gamma}-rays have been studied using a laboratory-scale apparatus. The SHLLW used was made up of 28 different metal elements, the concentrations of which were determined from a computed data (ORIGEN-2) for a Purex spent fuel (burn-up of 4.5 GWd/t, cooling time of 4 years) except for those of corrosion products (Fe, Cr and Ni) and of chemical process additive (P). The nitrate ion concentration of the SHLLW was 4.97 M. The G-value of hydrogen release was 0.0164 for stirred conditions, but for nonstirred conditions with dose rate : 2.8 kGy/h and with the SHLLW solution height more than 8 cm, the following relation was found between the G-value and the solution height (d cm); G(H{sub 2}) = 0.100 d{sup -1.6}. The G-values of oxygen and nitrogen releases were also determined. (author)

1997-12-01

89

Evaluation of value for hydrogen release from high-level liquid waste. 4. Hydrogen release rate for #gamma#-ray radiolysis of simulated purex waste solutions  

International Nuclear Information System (INIS)

The rates of hydrogen release from simulated high-level liquid waste (SHLLW) during irradiation of "6"0Co #gamma#-rays have been studied using a laboratory-scale apparatus. The SHLLW used was made up of 28 different metal elements, the concentrations of which were determined from a computed data (ORIGEN-2) for a Purex spent fuel (burn-up of 4.5 GWd/t, cooling time of 4 years) except for those of corrosion products (Fe, Cr and Ni) and of chemical process additive (P). The nitrate ion concentration of the SHLLW was 4.97 M. The G-value of hydrogen release was 0.0164 for stirred conditions, but for nonstirred conditions with dose rate : 2.8 kGy/h and with the SHLLW solution height more than 8 cm, the following relation was found between the G-value and the solution height (d cm); G(H_2) = 0.100 d"-"1"."6. The G-values of oxygen and nitrogen releases were also determined. (author).

1997-01-01

90

Evaluation of fungal burden of medicinal plants submitted to gamma radiation process after 30 days  

International Nuclear Information System (INIS)

Forty samples of medicinal plants (Peumus boldus, Camellia sinensis, Maytenus ilicifolia and Cassia angustifolia), purchased from pharmacies and street market in the five cities of Sao Paulo State, were irradiated using a "6"0Co gamma ray source (Gammacell) with a dose of 10.0 kGy, delivered at dose rate of 3.0 kGy/h. Nonirradiated samples were used as controls of fungal isolates. For fungal counts and identification in medicinal plants a serial dilutions from 10"-"1 to 10"-"6 of the samples were seeded in duplicates and plated using the method in Dichloran 18% Glycerol Agar (DG 18) and were counted after five days at 25 deg C. Mycological analysis of control samples revealed the presence of genera Aspergillus and Penicillium, which are known as toxigenic fungi. The process of gamma radiation was effective in reducing the number of colony forming units (cfu/g) in all irradiated samples of medicinal plants after 30 days, using the dose of 10.0 kGy and kept of veiled conditions. (author)

91

Evaluation of domperidone as a modifier of gamma-radiation-induced emesis. Report for January 1984-January 1986  

Energy Technology Data Exchange (ETDEWEB)

The D2 antidopaminergic drug Domperidone was evaluated singly and in combination with synthetic adrenocorticoid and an H2 antihistamine for its ability to reduce the acute emetic effects of /sup 60/Co whole-body radiation. Random-source adult male dogs were fasted 12 hours, fed a standard meal, injected 44 minutes later and irradiated 47 minutes after that. Four groups of dogs were radiated after drug injections as follows: saline (Con), domperidone (Dom), cimetidine + thiethylperazine (Cim+Thi), and dexamethasone + domperidone + cimetidine (Dex+Dom+Cim). Drug quantities for dogs represented 10 mg Dom, 10 mg Thi, 20 mg Dex, and 300 mg Cim for an average human (70 ka, 1.8 m2). Subjects were exposed on an up-down schedule to determine the radiation necessary to produce vomiting in 50% (ED50) of each group. Emesis onset times, offset times, and number of episodes were recorded. The ED50 of Dex+Dom+Cim was higher than Con. Dom produced more emetic ...

1987-09-01

92

Effects of irradiation in medicinal and eatable herbs  

International Nuclear Information System (INIS)

For ages, herbs have been used as medicine and food. Nowadays, the interest in phytotherapeutics is increasing as well as the consumer attention. Some biochemical compounds synthesized by plants as alkaloids, phenolics, flavonoids, essential oils, tannins and vitamins, influence the composition of these plant pharmacologicals, which may produce various reactions in the human body. The microbial contamination in these raw plant materials is common, and the radiation processing is one appropriate technique for the reduction of microorganism. In herbs used as food products, the changes in total #beta#-carotene and flavonoids upon the radiation treatment were tested. The powdered and dehydrated herbs were irradiated with "6"0Co gamma rays applying doses of 0, 10, 20 and 30 kGy. The botanical species investigated were rosemary (Rosmarinus officinalis Linne), watercress (Nasturtium officinale R. Br), artichoke (Cynara scolymus Linne) and sweet basil (Ocimum basilicum Linne). The alterations ...

2002-03-01

93

EPR investigation of some traditional oriental irradiated spices  

International Nuclear Information System (INIS)

The 9.50 GHz electron paramagnetic resonance (EPR) spectra of unirradiated and "6"0Co #gamma#-ray irradiated cardamom (Elettaria cardamomum L. Maton, Zingiberaceae), ginger ((Zingiber officinale Rosc., Zingiberaceae), and saffron (Crocus sativus L., Iridaceae) have been investigated at room temperature. All unirradiated spices presented a weak resonance line with g-factors around free-electron ones. After #gamma#-ray irradiation at an absorbed dose of up to 11.3 kGy, the presence of EPR spectra whose amplitude increase monotonously with the absorbed dose has been noticed with all spices. A 100 "oC isothermal annealing of 11.3 kGy irradiated samples has shown a differential reduction of amplitude of various components that compose initial spectra, but even after 3.6 h of thermal treatment, the remaining amplitude represents no less then 30% of the initial ones. The same peculiarities have been noticed after 83 days storage at room temperature but after 340 days storage at ambient ...

2007-06-01

94

EPR investigation of some irradiated traditional oriental spices  

International Nuclear Information System (INIS)

The X-band EPR spectra of unirradiated and "6"0 Co gamma ray irradiated cardamom (Elettaria cardamomum L. Maton, Zingiberaceae), ginger ((Zingiber officinale Rosc., Zingiberaceae), saffron (Crocus sativus L., Iridaceae), and curry have been investigated at room temperature. All unirradiated spices presented a weak resonance line with g-factors around free-electron ones, most probably due to the presence of semiquinones, previously reported to have paramagnetic properties. After gamma ray irradiation at absorbed dose up to 11.3 kGy we have noticed in all spices the presence of complex EPR spectra consisting of a superposition of at last two different paramagnetic species whose amplitude increase monotonously with the absorbed dose. A 100 deg. C isothermal annealing of 11.3 kGy irradiated samples has shown a differential reduction of amplitude of various components that form the initial spectra, but even after 5 h of thermal treatment, the remaining amplitude represents no less than 40% ...

2005-09-13

95

Decontamination performance in off-gas cleaning system of radioactive solid waste incineration unit  

International Nuclear Information System (INIS)

At the Tokai Research Establishment of Japan Atomic Energy Research Institute, the radioactive solid waste incineration unit with a capacity of 100 kg/h was installed in 1979, since then the unit has been routinly operated. An off-gas cleaning system of the unit consists mainly of a primary and secondary ceramic filters, a heat resistant HEPA filter and a scrubber. A series of hot test was carried out to examine the docontamination performance for radionuclides in the off-gas cleaning system. In the test, simulated wastes contaminated with a known quantity of radionuclides were burned in the unit, and radioactive concentrations in the off-gas were measured. And then, the following data were obtained: a retention factor of radionuclides in a furnace and a decontamination factor for radionuclides in each of off-gas cleaning components. And also overall decontamination factors, defined as the ratio of radioactivities input to the furnace to radioactivities passed through outlet of the ...

96

Calibration methods of plane-parallel ionization chambers used in electron dosimetry; Metodos de calibracao de camaras de ionizacao de placas paralelas para dosimetria de feixes de eletrons  

Energy Technology Data Exchange (ETDEWEB)

The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration certificate and data sheets are presented. (author)

1999-07-01

97

Application of the microbiological method DEFT/APC to detect minimally processed vegetables treated with gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

Marketing of minimally processed vegetables (MPV) are gaining impetus due to its convenience, freshness and apparent health effect. However, minimal processing does not reduce pathogenic microorganisms to safe levels. Food irradiation is used to extend the shelf life and to inactivate food-borne pathogens. In combination with minimal processing it could improve safety and quality of MPV. A microbiological screening method based on the use of direct epifluorescent filter technique (DEFT) and aerobic plate count (APC) has been established for the detection of irradiated foodstuffs. The aim of this study was to evaluate the applicability of this technique in detecting MPV irradiation. Samples from retail markets were irradiated with 0.5 and 1.0 kGy using a {sup 60}Co facility. In general, with a dose increment, DEFT counts remained similar independent of the irradiation while APC counts decreased gradually. The difference of the two counts ...

2009-07-15

98

Application od scaling technique for estimation of radionuclide inventory in radioactive waste  

International Nuclear Information System (INIS)

Safety studies related to the disposal of low- and intermediate waste indicate that the long term risk is determined by the presence of long-lived nuclides such as "1"4C, "5"9Ni, "6"3Ni, "9"9Tc, "1"2"9I and the transuranium elements. As most of these nuclides are difficult to measure, the correlation between these critical nuclides and some other easily measurable key nuclides such as "6"0Co and "1"3"7Cs has been investigated for typical waste streams of Paks Nuclear Power Plant (Hungary) and scaling factors have been proposed. An automated gamma-scanning monitor has been purchased and calibrated to determine the gamma-emitting radionuclides. Radiochemical methods have been developed to determine significant difficult-to-measure radionuclides. The radionuclides of interest have been "3H, "1"4C, "9"0Sr, "5"5Fe, "5"9Ni, "9"9Tc, "1"2"9I and TRUs. The measurements taken so far have revealed brand new information and data on radiological composition of waste of WWER-type reactors. The ...

1996-09-16

99

A new plateau in the dose-survival-time response of the golden hamster (Mesocricetus auratus) from whole body irradiation  

International Nuclear Information System (INIS)

The survival time of golden hamsters (Mesocricetus auratus) after whole-body "6"0Co-#gamma#-irradiation in the range of 600 to 200 000 rad was investigated. The two plateaus of the dose-survival curve which correspond to bone marrow and gastrointestinal death are similar to those of other species such as mice, rats and mongolian gerbils. A new plateau occurring 40-57 hours after doses of 30 000-60 000 rad, where there is a little reduction in survival time, has been found. It is in addition to the well recognized central nervous system (CNS) syndrome. This plateau is observed only in golden hamsters, presumably because of their relatively high resistance to CNS syndrome. Experiments involving partial body irradiation of the animals indicate that the target is in the cephalic one-third of abdomen. The new segment may well indicate a new type of acute somatic radiation injury different from the well known bone marrow, gastrointestinal and CNS syndromes. (author).

1981-01-01

100

Study of the electron beam irradiation effect on some properties of aromatic aliphatic copolyester films; Estudo do efeito da radiacao por feixe de eletrons nas propriedades de filmes de copoliester alifatico aromatico  

Energy Technology Data Exchange (ETDEWEB)

Biodegradable and green plastics are the new tendency in the world. The effect of the electron beam irradiation in aromatic aliphatic copolyester and the blend with corn starch films (Ecoflex{sup R} and Ecobras{sup R}) were studied by tensile strength at break, elongation at break, Scanning Electronic Microscopy (SEM), Fourier Transform Infrared Spectroscopy (FT-IR), Differential Scanning Calorimetry (DSC), crosslinking degree and biodegradability. The measurements in both, the machine direction and the transverse direction were made for mechanical tests. It was found that, the electron irradiation caused an increase in the strength at break of the blend with corn starch film, when doses of up to 10 kGy were applied. A significant decrease of the elongation at break of the blend with corn starch was observed at doses of 10 kGy and 40 kGy. It was not found important change in tensile properties for aromatic aliphatic copolyester. Structural changes of the samples (crosslinking or ...

2008-07-01

 
 
 
 
101

Multigroup Albedo Method applied to coupled neutron-gamma radiations shielding; Metodo multigrupo do albedo aplicado a blindagem de radiacoes neutron-gama acoplados  

Energy Technology Data Exchange (ETDEWEB)

Shielding calculations for neutron-gamma radiation are usually done by using the full Theory of Transport or the Monte Carlo Techniques. After some works based on the Albedo Method, the shielding calculations for neutron-gamma radiation have a reliable tool with great didactical value which shows its clarity and simplicity for the resolution of cases that involve neutrons and photon shielding in nonmultiplying media. The excellent results of these works have motivated the elaboration and the development of this study that will be presented in this dissertation. The balance of a neutronic current entering a shield of two layers considering the coupling neutron-gamma will be determined by the Albedo Method. The shield will be composed of a layer of iron and another one of manganese with 10 cm of thickness each. The arrays of the materials coefficients will be obtained from the ANISN code. ANISN is a one dimensional deterministic code that is based on transport equation. The final results ...

2001-07-01

102

Gamma irradiation in the control of pathogenic bacteria in refrigerated ground chicken meat; Irradiacao gama no controle de bacterias patogenicas em carne de frango refrigerada  

Energy Technology Data Exchange (ETDEWEB)

This work evaluated the effect of gamma radiation on reducing the population of Staphylococcus aureus, Escherichia coli nd Salmonella typhimurium in ground chicken breast stored under refrigeration. The experiment included a control and 4 doses of gamma radiation ( 2.0, 4.0, 6.0 and 8.0 kGy) along with 5 periods of storage under refrigeration ( 1, 7 14, 21 and 28 days). Samples of ground chicken breast were inoculated with Staphylococcus aureus (ATCC 14458), Escherichia coli (ATCC 11105) and Salmonella typhimurium (ATCC 0626), irradiated at temperatures between 4 and 8 deg C and stored under refrigeration (5 deg C) for 28 days. The increased radiation dose and period of storage under refrigeration caused a reduction of Staphylococcus aureus, Escherichia coli and Salmonella typhimurium populations in the ground chicken breast. Mean radiation D values determined for Staphylococcus aureus and Escherichia coli were 0.41 and 0.72 kGy, respectively. Gamma irradiation was an effective ...

2000-09-01

103

Analysis of coupled neutron-gamma radiations, applied to shieldings in multigroup albedo method; Analise das radiacoes neutron e gama acopladas, aplicada a blindagem com varias camadas pelo metodo multigrupo do albedo  

Energy Technology Data Exchange (ETDEWEB)

The principal mathematical tools frequently available for calculations in Nuclear Engineering, including coupled neutron-gamma radiations shielding problems, involve the full Transport Theory or the Monte Carlo techniques. The Multigroup Albedo Method applied to shieldings is characterized by following the radiations through distinct layers of materials, allowing the determination of the neutron and gamma fractions reflected from, transmitted through and absorbed in the irradiated media when a neutronic stream hits the first layer of material, independently of flux calculations. Then, the method is a complementary tool of great didactic value due to its clarity and simplicity in solving neutron and/or gamma shielding problems. The outstanding results achieved in previous works motivated the elaboration and the development of this study that is presented in this dissertation. The radiation balance resulting from the incidence of a neutronic stream into a shielding composed by ...

2002-07-01

104

The interaction of alcohol radicals with human hemoglobin. Pt. 1. Spectral properties of hemoglobin in the visible range  

International Nuclear Information System (INIS)

Aqueous deoxyhemoglobin solutions (2 mg/ml) were gamma-irradiated by a "6"0Co source in the presence of methanol, ethanol, 1-butanol and t-butanol under N_2O or argon. The effects of the interaction of the particular alcohol radical species with hemoglobin were determined according to the detected spectral alterations in the visible range. The amounts of stable final products in the form of methemoglobin (MetHb) and the sum of hemichromes and cholehemichromes (Hemichr) were estimated in irradiated preparations. For preparations irradiated under N_2O, the radiation yield for MetHb formation was three-fold lower in the presence of ethanol and 1-butanol [G(MetHb) = 0.33[ compared with preparations irradiated in the presence of t-butanol or without alcohol [G(MetHb) = 1.00[. The yield of hemichromes and cholehemichromes in preparations irradiated under N_2O increased in the order: ethanol (G = 0.38), 1-butanol (B = 0.52), t-butanol (G = 0.59), and in the absence of alcohol (G 0.72). The ...

105

The influence of modified water chemistries on metal oxide films, activity build-up and stress corrosion cracking of structural materials in nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

The primary coolant oxidises the surfaces of construction materials in nuclear power plants. The properties of the oxide films influence significantly the extent of incorporation of actuated corrosion products into the primary circuit surfaces, which may cause additional occupational doses for the maintenance personnel. The physical and chemical properties of the oxide films play also an important role in different forms of corrosion observed in power plants. This report gives a short overview of the factors influencing activity build-up and corrosion phenomena in nuclear power plants. Furthermore, the most recent modifications in the water chemistry to decrease these risks are discussed. A special focus is put on zinc water chemistry, and a preliminary discussion on the mechanism via which zinc influences activity build-up is presented. Even though the exact mechanisms by which zinc acts are not yet known, it is assumed that Zn may block the diffusion paths within the oxide film. This ...

1999-03-01

106

Testing of CoTreat Inorganic Ion Exchange Media for the Removal of 60Co from Thorp Pond Water  

Energy Technology Data Exchange (ETDEWEB)

CoTreat, a new inorganic ion exchange media, has been studied in the laboratory to support its application as a pre- coat to existing Funda filters in THORP feed pond plant (Sellafield, UK). This is a novel way of application of CoTreat, which is usually utilized in fixed-bed ion exchange columns in a granular form. The results present the effect of operating conditions (CoTreat dose, pond water chemistry) on CoTreat performance for the removal of Co-57 tracer from simulated pond water. Major findings include the strong dependence of Co-57 decontamination factor (DF) on feed activity. At the 200 Bq/L feed level, the observed DF was 10-20 but rose to 1000 and above when the feed level was increased to 20000 Bq/L. Calcium present in the feed was found to decrease the DF at concentrations higher than 1 ppm. The laboratory studies showed significantly higher DF's than what has been observed in large-scale THORP tests. This discrepancy is likely to be due to the technique used in ...

2003-02-25

107

Semi-empirical simulation of thermoluminescent response under different filter geometries; Simulacao semi-empirica da resposta termoluminescente sob diferentes geometrias de filtro  

Energy Technology Data Exchange (ETDEWEB)

Many thermoluminescent materials has been developed and used for photon personal dosimetry but no one has all desired characteristics alone. These characteristics include robustness, high sensitivity, energy photon independence, large range of photon energy detection, good reproducibility, small fading and simple glow curve with peaks above 150 deg C. Calcium Sulfate Dysprosium doped (CaSO{sub 4}:Dy) phosphor Thermoluminescent Dosimeter (TLD) has been used by many laboratories, mainly in Brazil and India. Another interesting phosphor is Calcium Fluoride (CaF{sub 2}). These phosphor advantages begin to be more required and its disadvantages have became more apparent, in a global market more and more competitive. These phosphors are used in environmental and area monitoring, once they present more sensibility than other phosphors, like LiF:Mg. Theirs mainly disadvantage is a strong energetic dependence response, which must be corrected for theirs application in the field, where photon ...

2006-07-01

108

Safe detection of Co-60. New perspectives in contamination and clearance measurements  

International Nuclear Information System (INIS)

Consistent application of a newly developed coincidence technique to determine activation products in the operation and demolition of nuclear facilities results in very new perspectives in contamination monitoring and clearance measurement of plant components. In particular, it is possible to avoid the critical spread of point-source Co-60 contamination, the so-called hot particles. The CCM (Cobalt Coincidence Measurement) technique includes the coincident detection of prompt-prompt gamma cascades with "6"0Co and other activation products ("1"1"0"mAg, "1"2"4Sb, "2"2Na) with low mass-specific limits for unrestricted clearance. Special features of the technique are the short measurement times, excellent signal-to-noise ratio, and focusing in space achieved. Compared to conventional integral gamma-measurements, the signal-to-background ratio can be improved by 1-2 orders of magnitude. The method can be employed especially where conventional integral or spectroscopic methods suffer from ...

109

Response of a non-Hodgkin lymphoma to "6"0Co therapy monitored by 31P MRS in situ  

International Nuclear Information System (INIS)

High quality "3"1P MR spectra (signal to noise ratio (S/N) approximately 18, 15 min acquisition for each spectrum) were consistently obtained with surface coils over a period of 6-week RT. Both transient and steady state alterations in metabolites in response to RT were found in this case. The transient changes occurred during the first 3 hr immediately after the 3rd fractionated RT, these changes include the transient elevation of the PCr resonance, a decrease in PDE and an increase in intracellular pH. The monitoring showed that the metabolites approached steady state approximately 2 hr after the fractionated radiation intervention, suggesting that in vivo MRS can be useful for studying the dynamics of tumor response to RT such as repair of potential lethal damage, growth delay, and reoxygenation etc. The steady-state MR spectra showed the net response to each intervention and can clinically be useful for predicting and measuring the result of the fractionated RT. In this case study, ...

110

RangerMaster{trademark}: Real-time pattern recognition software for in-field analysis of radiation sources  

Energy Technology Data Exchange (ETDEWEB)

RangerMaster{trademark} is the embedded firmware for Quantrad Sensor`s integrated nuclear instrument package, the Ranger{trademark}. The Ranger{trademark}, which is both a gamma-ray and neutron detection system, was originally developed at Los Alamos National Laboratory for in situ surveys at the Plutonium Facility to confirm the presence of nuclear materials. The new RangerMaster{trademark} software expands the library of isotopes and simplifies the operation of the instrument by providing an easy mode suitable for untrained operators. The expanded library of the Ranger{trademark} now includes medical isotopes {sup 99}Tc, {sup 201}Tl, {sup 111}In, {sup 67}Ga, {sup 133}Xe, {sup 103}Pa, and {sup 131}I; industrial isotopes {sup 241}Am, {sup 57}Co, {sup 133}Ba, {sup 137}Cs, {sup 40}K, {sup 60}Co, {sup 232}Th, {sup 226}Ra, and {sup 207}Bi; and nuclear materials {sup 235}U, {sup 238}U, {sup 233}U, and {sup 239}Pu. To accomplish isotopic ...

1998-12-31

111

Radiochemical determination of neutron capture cross sections of {sup 241}Am  

Energy Technology Data Exchange (ETDEWEB)

The thermal neutron capture cross sections and the neutron capture resonance integrals of {sup 241}Am leading to the production of the isomer {sup 242m}Am and the ground-state {sup 242g}Am were measured radiochemically by the Cd-ratio technique with neutron flux monitors of Co/Al and Au/Al alloy. Highly-purified {sup 241}Am targets were irradiated in an aluminum capsule by using JMTR. The neutron fluxes and their epithermal neutron fractions were determined by measuring {gamma}-rays of {sup 60}Co and {sup 198}Au. The yields of {sup 242m}Am and {sup 242g}Am were decided by analyzing growth and decay curves of the {alpha}-ray activity ratios {sup 242}Cm/{sup 241}Am. The resultant thermal neutron capture cross sections are 85.7 {+-} 6.3 b and 768 {+-} 58 b for {sup 242m}Am and {sup 242g}Am, and the resonance integrals 114 {+-} 7 b and 1,694 {+-} 146 b, respectively. The differences between the present results and the evaluated values by Mughabghab ...

1997-07-01

112

Radiation testing of organic ion exchange resins  

International Nuclear Information System (INIS)

A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of "1"3"7Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the exchangers were irradiated with a "6"0Co source to a total absorbed dose ...

1983-04-11

113

Radiation testing of organic ion exchange resins  

Energy Technology Data Exchange (ETDEWEB)

A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of {sup 137}Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the exchangers were irradiated with a {sup ...

1995-09-01

114

Optimizing the radiosensitive liquid-core microcapsules for the targeting of chemotherapeutic agents  

Energy Technology Data Exchange (ETDEWEB)

Microcapsules consisting of alginate and hyaluronic acid that can be decomposed by radiation are currently under development. In this study, the composition of the microcapsule material was optimized by changing the amounts of alginate and hyaluronic acid. Solutions of 0.025%, 0.05%, 0.1%, 0.2%, or 0.4% (wt./vol.) hyaluronic acid were mixed into a 0.2% alginate solution. To these mixtures, carboplatin (0.2 mmol) was added and the resulting material was used for the capsule preparation. The capsules were prepared by spraying the material into a CaCl{sub 2} solution (0.34 mol/l) using a microatomizer. These capsules were irradiated by a single dose of 2, 5, or 10 Gy {sup 60}Co {gamma}-ray radiation. Immediately after irradiation, the releasing of core content of microcapsule was determined, using a micro particle induced X-ray emission (PIXE) camera. The average diameter of the microcapsules was 22.3 {+-} 3.3 {mu}m, and that of the liquid core ...

2007-07-15

115

International Symposium on Nuclear Energy SIEN 2009. Nuclear Power - A New Challenge  

International Nuclear Information System (INIS)

The SIEN 2009 symposium organized by Romanian Nuclear Energy Association, AREN, in co-operation with Romanian Atomic Forum, ROMATOM, was primarily targeting the expert community involved in developing new nuclear power projects and implementing the National Nuclear Program. The symposium was also open as a discussion and information forum for scientists, engineers, technicians and students interested in scientific and technologic topics of Nuclear Power. It was structured in the following 6 sections: - Nuclear new builds and developments; - Operation, inspection and maintenance; - Increasing nuclear safety features; - Fuel cycle and decommissioning; - Public perception and confidence strengthening; - Environmental management. The symposium began with three plenary lectures dealing with: - Sustainable Nuclear Energy European Technology Platform; - Nuclear new-build; - Current issues of nuclear equipment standardization in Romania. A poster session of 5 presentations and a workshop ...

2009-10-12

116

Instrumentation for monitoring and control of water chemistry for light-water-cooled nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

Based on the IAPWS technical guidance on ''Instrumentation for Monitoring and Control of Cycle Chemistry for Steam-Water Circuits of Fossil-Fired and Combined Cycle Power Plants,'' the latest situation regarding instrumentation for nuclear power plants is discussed. As a result of the discussion, it is concluded that: (1) Reliable and safe operation of plants is established by the application of suitable chemical conditions in plant cooling systems, which should be supported by the selection of suitable control targets for monitoring and by the application of reliable instruments. (2) The minimum level of key instrumentation consists of on-line as well as off-line instruments for monitoring the key parameters: - on-line: pH, conductivity, cation conductivity, O{sub 2} and H{sub 2} concentrations, electrochemical corrosion potential; - off-line: radioactive nuclides ({sup 60}Co, {sup 58}Co, {sup 131}I, etc.), ...

2010-05-15

117

Fate of corrosion products released from stainless steel in marine sediments and seawater. Part 3. Calcareous ooze  

International Nuclear Information System (INIS)

The physicochemical forms and partitioning of corrosion products released from stainless steel upon exposure to selected environmental conditions is the subject of this investigation. This report describes the influence of calcareous sediment on the rate of release and fate of corrosion products produced when neutron-activated stainless steel specimens were exposed to a Globigerina ooze taken from the Northeast Pacific Ocean. The calcareous ooze used in this study consists largely of planktonic formanifera tests and was found to be about 90% CaCO_3. The trace metal content of this sediment was typical of average deep-sea carbonate sediments, and the ratios of trace elements to Ti were not remarkably different from a coastal clayey silt or a Northeast Pacific pelagic red clay. Most (>80%) of the trace metals extracted by sequential chemical treatment were associated with reductant-soluble materials, i.e., amorphous Mn and Fe oxides, or were incorporated in the carbonate substrate. ...

118

Evaluation of fungal bio burden and mycotoxins presence in irradiated samples of medicinal plants purchased from wholesale and retail market  

International Nuclear Information System (INIS)

This present study evaluated the effect of gamma radiation on the fungal survival in packed medicinal plants, purchased from wholesale and retail market, in different period (0 and 30 days) after the treatment. Five kind of medicinal plants (Peumus boldus, Camellia sinensis, Maytenus ilicifolia, Paullinia cupana and Cassia angustifolia), were collected from different cities of Sao Paulo State, and submitted to irradiation treatment using a 60Co source (type Gammacell 220) with doses of 5,0 kGy and 10 kGy and at dose rate of 3.0 kGy/h. Non-irradiated samples (control group) were used for fungal counts and serial dilutions from 10-1 to 10-6 of the samples were seeded in duplicates and plated using the surface culture method in Dichloran 18% Glycerol Agar (DG 18) and were counted after five days at 25 deg C. The control group revealed the presence of genera Aspergillus and Penicillium, which are known as toxigenic fungi and a few samples of ...

2006-12-20

119

Environmental and plant effects of sewage sludge application to forests and pastures  

Energy Technology Data Exchange (ETDEWEB)

Digested sewage sludge was applied to pastures and tree plantations at 19 to 44 Mg/ha (dry weight) as part of a municipal sludge disposal program. The sludge had low concentrations of heavy metals and traces of /sup 137/Cs and /sup 60/Co. Monitoring of soils, soil solutions, and runoff indicated that N, P, heavy metals, and radionuclides were largely retained in the upper 15cm of the soil. Soil solutions had elevated NO/sub 3//sup /minus// concentrations often >100 mg/L, but no significant increases in groundwater NO/sub 3//sup /minus// were found during the first year. Runoff from active sites had elevated concentrations of NO/sub 3//sup /minus// (20--30 mg/L), soluble P (1 mg/L), BOD/sub 5/ (5--30 mg/L), and fecal coliform (up to 14,000 colonies per 100 ml), not unlike runoff from pastures with cattle. Enrichment of organic N (2 times), available (inorganic) N (5 to 10 times), and Bray-P in the upper soils persisted for several years ...

1989-01-01

120

Emesis ED50 of neutron irradiation and prophylactic effectiveness. Final report, 1 January 1979-31 December 1984  

Energy Technology Data Exchange (ETDEWEB)

Two neutron emesis experiments were conducted at the Armed Forces Radiobiology Research Institute (AFRRI). In both experiments (described as Phase I and Phase II) the radiation dose required to cause emesis in 50% of subjects (ED50) was determined for both neutron reactor and gamma reactor source radiation. Emesis onset, offset and duration times post-exposure are reported. Neutrons were maximized from the reactor by passing the beam through a 15.25 cm (6 in.) thick lead wall to filter out gamma photons. Gamma rays were maximized by thermalizing neutrons in 30.5 cm (12 in.) of water, then absorbing the thermal neutrons in a gadolinium-cadmium shield. In Phase I, 28 dogs were exposed to radiation: 12 were exposed to gamma photons at the rate of 0.69 Gy/min and 16 were exposed to neutrons at 1.2 Gy/min. In Phase II, 58 dogs in 3 groups were exposed to radiation: 19 were exposed in the gamma group at 0.75 Gy/min, 20 were exposed in the undrugged neutron group at 1.62 Gy/min, and 19 were ...

1985-08-01

 
 
 
 
121

Effects of gamma-irradiation on the TL characteristics of pre-annealed natural ZrSiO{sub 4}  

Energy Technology Data Exchange (ETDEWEB)

By the use of thermoluminescence (TL) technique we have investigated the effects of gamma irradiation on the TL response of pulverised natural zircon (ZrSiO{sub 4}) crystals from the Jos Plateau area of Nigeria. Samples of the mineral that have been previously annealed were artificially irradiated to moderate gamma doses ranging from 0.7 to 4.9 Gy using {sup 60}Co gamma-source of the CERD. The natural TL glow curve of the sample showed a broad peak around 250 deg. C, the peak was however, found to be completely erased following heat treatment for 2 h at 400 deg. C. The TL glow curves of the artificially irradiated samples showed two overlapping glow peaks at about 112 deg. C (peak I) and at 156 deg. C (peak II) within the dose range utilised. We note that the natural TL peak appears to be different from the two observed in the artificially irradiated sample. The TL response with dose was investigated for the two glow peaks found in the ...

2005-10-15

122

Effects of gamma-irradiation on the TL characteristics of pre-annealed natural ZrSiO_4  

International Nuclear Information System (INIS)

By the use of thermoluminescence (TL) technique we have investigated the effects of gamma irradiation on the TL response of pulverised natural zircon (ZrSiO_4) crystals from the Jos Plateau area of Nigeria. Samples of the mineral that have been previously annealed were artificially irradiated to moderate gamma doses ranging from 0.7 to 4.9 Gy using "6"0Co gamma-source of the CERD. The natural TL glow curve of the sample showed a broad peak around 250 deg. C, the peak was however, found to be completely erased following heat treatment for 2 h at 400 deg. C. The TL glow curves of the artificially irradiated samples showed two overlapping glow peaks at about 112 deg. C (peak I) and at 156 deg. C (peak II) within the dose range utilised. We note that the natural TL peak appears to be different from the two observed in the artificially irradiated sample. The TL response with dose was investigated for the two glow peaks found in the artificially irradiated sample and in both cases, in the ...

2005-10-01

123

Effect of {gamma}-radiation on migration behaviour of dioctyladipate and acetyltributylcitrate plasticizers from food-grade PVC and PVDC/PVC films into olive oil  

Energy Technology Data Exchange (ETDEWEB)

Food-grade PVC and PVDC/PVC films containing 28.3% dioctyladipate (DOA) and 5.0% acetyltributylcitrate (ATBC) plasticizers, respectively, were brought into contact with olive oil and were irradiated with {gamma}-radiation [{sup 60}Co] at doses equal to 4 kGy and 9 kGy corresponding to `cold pasteurization`. Irradiation was carried out at 8-10 C and samples were subsequently stored at 4-5 C. Contaminated oil samples were analysed for DOA and ATBC at intervals between 7 h and 97 h of contact, using an indirect GC method. Identical non-irradiated (control) samples were also analysed for DOA and ATBC content. Results showed no statistically significant differences in migrated amounts of DOA and ATBC between irradiated and non-irradiated samples. Neither were differences observed between samples irradiated at 4 kGy and 9 kGy. This was supported by identical IR spectra recorded for irradiated and non-irradiated samples and leads to the conclusion ...

1995-12-31

124

Effect of salt stress and phosphorus deficiency in mutants of rhizobium obtained by gamma irradiation  

International Nuclear Information System (INIS)

Two strains of Rhizobium: Rhizobium Tropici and Mesorhizobium Ciceri nodulating respectively common bean and chickpea were treated by gamma irradiation (60Co) source. Radiosensibility analysis showed that 800 Gy was the biggest dose supported by these two strains. We isolated gamma irradiated resistant strain in order to select mutant of them which can supported salt stress and phosphorus deficiency. Salinity analysis showed that Mesorhizobium Ciceri 835 strain, can tolerate up to 18g/l (273 mM NaCl) of salt, whereas, their irradiation mutants tolerate salinity up to 33g/l (564mM. NaCl) Rhizobium Tropici CIAT899 can survive at 20g/l (342 mM) either for control strain or mutants. Analysis of phosphorus deficiency showed that either Rhizobium Tropici CIAT899, or Mesorhizobium Ciceri 835 can survive in medium without phosphore. Our results permit us to screen mutants tolerant to these stresses wide spread in Mediterranean soil. In this study, we ...

2008-08-12

125

Dose coefficients for intakes of radionuclides via contaminated wounds.  

Science.gov (United States)

The NCRP Wound Model, which describes the retention of selected radionuclides at the site of a contaminated wound and their uptake into the transfer compartment, has been combined with the ICRP element-specific systemic models for those radionuclides to derive dose coefficients for intakes via contaminated wounds. These coefficients can be used to generate derived regulatory guidance (i.e., the activity in a wound that would result in an effective dose of 20 or 50 mSv, or in some cases, a organ-equivalent dose of 500 mSv) and clinical decision guidance (i.e., activity levels that would indicate the need for consideration of medical intervention to remove activity from the wound site, administration of decorporation therapy or both). Data are provided for 38 radionuclides commonly encountered in various activities such as nuclear weapons, fuel fabrication or recycling, waste disposal, medicine, research, and nuclear power. These include 3H, 14C, 32P, 35S, 59Fe, ...

2011-05-01

126

Deterministic calculations of radiation doses from brachytherapy seeds  

International Nuclear Information System (INIS)

Brachytherapy is used for treating certain types of cancer by inserting radioactive sources into tumours. CDTN/CNEN is developing brachytherapy seeds to be used mainly in prostate cancer treatment. Dose calculations play a very significant role in the characterization of the developed seeds. The current state-of-the-art of computation dosimetry relies on Monte Carlo methods using, for instance, MCNP codes. However, deterministic calculations have some advantages, as, for example, short computer time to find solutions. This paper presents a software developed to calculate doses in a two-dimensional space surrounding the seed, using a deterministic algorithm. The analysed seeds consist of capsules similar to IMC6711 (OncoSeed), that are commercially available. The exposure rates and absorbed doses are computed using the Sievert integral and the Meisberger third order polynomial, respectively. The software also allows the isodose visualization at the surface plan. The user can choose ...

2003-08-17

127

Cytogenetic effects of protracted gamma exposures from conception of male mice  

Energy Technology Data Exchange (ETDEWEB)

In order to gain an overall picture of the genetic effects of an increased level of background radiation it is necessary to study the results of protracted exposures to embryonic and immature germ-cell stages as well as to stages found in the mature organism. For this purpose, litters produced by female mice, kept in a 10 or 20 rad/day /sup 60/Co ..gamma..-irradiation field, were kept in the same fields from conception until about 60 days later, having absorbed doses of 526 and 1078 rad respectively. Tests on exposed female offspring showed them to be sterile. Eight weeks after removal from the gamma field, mean testis masses of males in the 20 rad/day series were only half normal but those receiving 10 rad/day were little affected. Frequencies of translocations in spermatocytes at diakinesis/metaphase I were only slightly increased in the exposed series, differences not being significant. Estimated rates of translocation induction were around ...

1982-01-01

128

Calibration of the Capintec CRC-712M dose calibrator for "1"8F  

International Nuclear Information System (INIS)

Primary standardisation was performed on a solution of "1"8F using the 4#pi##beta#-#gamma# coincidence counting efficiency-tracing extrapolation method with "6"0Co used as a tracer nuclide. The result was used to calibrate the ANSTO secondary standard ionisation chamber which is used to disseminate Australian activity standards for gamma emitters. Using the secondary activity standard for "1"8F, the Capintec CRC-712M dose calibrator at the Australian National Medical Cyclotron (NMC) Positron Emission Tomography (PET) Quality Control (QC) Section was calibrated. The dial setting number recommended by the manufacturer for the measurement of the activity of "1"8F is 439. In this work, the dial setting numbers for the activity measurement of the solution of "1"8F in Wheaton vials were experimentally determined to be 443+/-12, 446+/-12, 459+/-11, 473+/-15 for 0.1, 1, 4.5 and 9ml solution volumes, respectively. The uncertainties given above are expanded uncertainties (k=2) giving an ...

2006-04-01

129

Busted Butte report on laboratory radionuclide migration experiments in non-welded tuff under unsaturated conditions  

Energy Technology Data Exchange (ETDEWEB)

Three blocks of non-welded tuff, one nominally one cubic foot (trial block) and the other two, nominally one cubic metre (1 m{sup 3}), were excavated from the Busted Butte Test Facility on the Nevada Test Site and transported to the Atomic Energy of Canada Limited Whiteshell Laboratories in Pinawa, Manitoba. The trial block and one of the 1-m{sup 3} blocks were used for unsaturated flow experiments. The remaining 1-m{sup 3} block is being used for saturated flow experiments and will be reported on separately. After a vertical flow of synthetic transport solution was set up under unsaturated conditions, a suite of conservative and chemically reactive radionuclide tracers was injected at volumetric flow rates of 20 mL/hr in the trial block, and 10 mL/hr in the 1-m{sup 3} block. The duration of the migration experiment in the trial block was 87 days, while the migration experiment in the 1-m{sup 3} block was continuing after 600 days. Results obtained from the migration experiment in the ...

2002-11-01

130

Activation analysis of trace elements in titanium-molybdate target used for pre-formed TiMo gel based "9"9"mTc generator production and radionuclidic impurity of "9"9"mTc pertechnetate eluate  

International Nuclear Information System (INIS)

A gel-type "9"9Mo-"9"9"mTc generator using Titanium-Molybdate target (TiMo-target) as column packing was developed in Radioisotope Department, the Dalat Nuclear Research Institute [1]. The concentration of trace elements in TiMo-target and radionuclidic purity in "9"9"mTc solution eluted from this type of generator were studied for quality control purpose. The monostandard method in neutron activation analysis has been applied to determine the concentration of trace impurities in titanium-molybdate target. For neutron activation analysis, TiMo samples were irradiated in the different channels of nuclear reactor IVV-9 at a neutron flux of maximum 2.1 x 10"1"3 n.cm"-"2s"-"1. The following chemical element impurities were determined: Na, W, Co, Fe, Zn, Ag, Sb and Cr. The gamma ray emitted nuclides found in "9"9"mTc solution eluted from our "9"9"mTc generator were the following: "6"5Zn, "6"0Co, "1"1"0"mAg, "5"9Fe, "5"1Cr, "2"4Na, "8"2Br and "9"9Mo. "9"9Mo was found less than 2.10"-"6mCi ...

2004-06-01

131

Project SAFE. Update of the SFR-1 safety assessment. Phase 1. Appendix A1: Inventory  

Energy Technology Data Exchange (ETDEWEB)

One of the aims in the safety assessment of SFR-1 is to estimate the release to the environment. In order to make these calculations there is a need to describe the inventory in greater detail. The new computerised database of waste in SFR-1 gives a good possibility to achieve this. The aim for project SAFE is to make both conservative and realistic radionuclide transport calculations. To achieve this goal there must be two inventories. The conservative inventory is the inventory used in the design of the repository, which in most parts is identical with the limits in the licence for SFR-1. There is a great interest to have good estimates of the volumes of the different waste types. A thorough prognosis should be made in 1999, but until then the latest one from 1995 could be used in the calculations. The total (actual) inventory of nuclides is calculated from the measurements of the easy-to-measure nuclides since, in principle, all hard-to-measure nuclides are calculated by correlation ...

1998-10-01

132

Busted Butte : final report on laboratory radionuclide migration experiments in non-welded tuff under unsaturated and saturated conditions  

International Nuclear Information System (INIS)

Three blocks of non-welded tuff, one nominally one cubic foot (trial block) in volume and the other two, nominally one cubic meter (1 m3) in volume, were excavated from the Busted Butte Test Facility on the Nevada Test Site in 1999 and transported to the Atomic Energy of Canada Limited Whiteshell Laboratories in Pinawa, Manitoba. The trial block and one of the 1-m3 blocks were used for radionuclide migration experiments under unsaturated conditions; the remaining 1-m3 block was used for similar migration experiments under saturated conditions. After a vertical flow of synthetic transport solution was set up under unsaturated conditions, a suite of conservative and chemically reactive radionuclide tracers was injected at volumetric flow rates of 20 mL/hr in the trial block, and 10 mL/hr in two locations on the upper surface of the 1-m3 block. These flow rates correspond to infiltration rates of about 120 cm/year and about 17 cm/year, respectively. The duration of the migration ...

2005-09-13

133

Neutron beam experiments using nuclear research reactors: honoring the retirement of professor Bernard W. Wehring -II. 4. Accurate Characterization of the Shape of the HPGe Detector Peak Efficiency Curve for Application in PGNAA  

International Nuclear Information System (INIS)

In various situations, measurements in prompt gamma neutron activation analysis (PGNAA) are performed to determine the amount of an elemental impurity relative to that of a major constituent of the matrix. An example of this is the measurement of hydrogen concentration in a metallic matrix. In all such cases, a major contributor to the uncertainty in the measurement is the uncertainty in the ratio of the high-purity germanium (HPGe) detector full-energy peak efficiency for the gamma-ray lines of interest (i.e., impurity and matrix gammas). Usually, the ratio is derived from the relative peak efficiency curve, which is determined using isotopic standards that emit multiple gamma ray lines (e.g., "1"5"2Eu) in the energy range <3000 keV, or using prompt gamma radionuclides (e.g., "1"4N, "3"5Cl) in the energy range >3000 keV. In either case, the uncertainty in the ratio of the peak efficiency values derived from such measurements will be on the order of a few percent at best because ...

2001-06-17