Mid-latitude scintillation model. Technical report, 1 November 1985-31 October 1986  

Energy Technology Data Exchange (ETDEWEB)

Radiowave scintillation in the presence of ionospheric disturbances has the potential to disrupt numerous transionospheric radio and radar systems. This report describes development of a model characterizing the plasma density irregularities that produce scintillation in the naturally disturbed mid-latitude F layer. The model will be incorporated into Program WBMOD, which includes subroutines for computing both link geometry and scintillation indices, the latter by means of phase screen diffraction theory. Earlier versions of WBMOD, were based on extensive analysis of scintillation data collected in the auroral and equatorial zones in Wideband Satellite Mission. The model described herein is based on similarly extensive analysis of Wideband data from one mid latitude station and of data collected from HiLat satellite at another mid latitude station. The model describes irregularities at an effective height of 350 km that ...

1986-10-31

2

Electromagnetic fields - introduction to relevant issues  

International Nuclear Information System (INIS)

This introductory paper surveys potential sources of electric magnetic, and electro-magnetic fields. Various cases are discussed to exemplify the total frequency range: nuclear magnetic resonance tomography, high-voltage transmission lines, transformer stations, effect lighting balls, military transmitters, transmitter towers of the Postal Services and other operators, mobile radiotelephone equipment, large broadcasting transmitters, radar radiation, high-frequency heat therapy. There is evidence suggesting that electric, magnetic and electro-magnetic fields may possibly represent a certain nuisance or health hazard even at field strength occuring in equipment used for every-day-life purposes, with an emphasis on their possible actions and effects in children and adolescents. The author discusses, in conclusion, the aerial equipment ordinance issued by Lower Saxony. (Uhe).

1993-06-01

3

The effect of local circulations on the variation of atmospheric pollutants in the northwestern Taiwan  

Energy Technology Data Exchange (ETDEWEB)

A field experiment was held in the northwestern Taiwan as a part of a long-term research program for studying Taiwan`s local circulation. The program has been named as Taiwan Regional-circulation Experiment (TREX). The particular goal of this research is to investigate characteristics of boundary layer and local Circulation and their impact on the distribution and Variation of pollutants in the northwestern Taiwan during Mei-Yu season. It has been known for quite sometime that land-sea breeze is very pronounced under hot and humid conditions. Extensive network includes 11 pilot ballon stations, 3 acoustic sounding sites, and 14 surface stations in about 20 km by 20 km area centered at National Central University, Chung-Li. In addition, there are ground temperature measurements at 3 sites, Integrated Sounding System (ISS) at NCU, air plane observation, tracer experiment with 10 collecting stations, 3 background upper-air ...

1996-12-31

4

A submillimeter wavelength space-based imaging radar  

Science.gov (United States)

This report considers the use of a submillimeter wavelength space-based imaging radar. The main application envisioned is midcourse decoy discrimination for strategic defense, for which it would have the capability of producing a series of images, in real time, at strategic ranges, with less than meter scale resolution and with modest power requirements. Undoubtedly, there are other applications. The requirements for a SAR and ISAR imaging radar at submillimeter wavelength are determined, and the prospect for the development of RF sources to power the radar is examined.

1988-05-01

5

NRL Fact Book 2010  

Science.gov (United States)

... Tactical Electronic Warfare Division (Code 5700) Visualization Laboratory Transportable step frequency radar Vehicle development laboratory ...

2011-05-15

6

NRL Fact Book  

Science.gov (United States)

... Tactical Electronic Warfare Division (Code 5700) Visualization Laboratory Transportable step frequency radar Vehicle development laboratory ...

2011-05-15

7

Foundation Investigation for Ground Based Radar Project ...  

Science.gov (United States)

... For the P-wave test, the seismic source was an exploding bridgewire (EBW) detonator which was sufficiently strong in energy ...

1990-04-01

8

Modeling Radar Scattering from the Lunar Surface and Analysis of the Effect of Roughness and Ice Inclusions on CPR Values  

Science.gov (United States)

We developed a model for radar scattering from the lunar reoglith layer using vector radiative transfer theory. From this model, both the radar backscattering coefficient and the circular polarization ratio can be predicted analytically as a function of regolith parameters.

2010-03-01

9

Analysis of the role of the planetary boundary layer schemes during a severe convective storm  

Energy Technology Data Exchange (ETDEWEB)

The role played by planetary boundary layer (PBL) in the development and evolution of a severe convective storm is studied by means of meso-scale modeling and surface and upper air observations. The severe convective precipitation event that occurred on 14 September 1999 in the northeast of the Iberian Peninsula was simulated by means of the mesoscale model MM5 (version 3) using three different PBL schemes. The numerical results show a large impact of the PBL schemes on the precipitation fields associated to the convective storm. The schemes are based on different physical assumptions: the nonlocal first order medium-range forecast (MRF) and blackadar (BLA) scheme and the local, one-and-a-half order ETA scheme. Surface and radar observations are used to validate the model results. The comparison focuses on three aspects: the evolution, the spatial distribution and the 24-h accumulated precipitation. The comparison with rain gauge observations shows that the MRF, ...

2004-07-01

10

Equatorial scintillation model. Technical report, 1 February 1983-30 April 1985  

Energy Technology Data Exchange (ETDEWEB)

Radiowave scintillation in the presence of natural and/or high-altitude nuclear disturbances has the potential to disrupt numerous transionospheric radio and radar systems. This report develops a model characterizing the plasma-density irregularities that produce scintillation in the naturally disturbed equatorial F layer. The model is incorporated into Program WBMOD along with subroutines for computing both link geometry and scintillation indices, the latter by means of phase screen diffraction theory. The model is based on similarly extensive analysis of wideband data from two equatorial stations. It describes irregularities at an effective height of 350 km that are isotropic across the geomagnetic field and elongated by a factor of 50 along the field and whose one-dimensional spatial power spectrum obeys a single-regime power law with a (negative) spectral index of 1.5. The height-integrated spectral strength of the irregularities is modeled ...

1985-09-30

11

The Anniversary History of Weather Radar Research (40th) in ...  

Science.gov (United States)

... water content according to the hydrometeor type. ... the documentation and the movement personnel and ... Dyer, RM, 1970: Particle fall speeds within ...

1989-01-30

12

SEEK IGLOO Radar Clutter Study  

Science.gov (United States)

... 17 IV. Spatial Amplitude Distributions of Terrain and Sea.....23 Clutter V, Spectral Density Measurements ..... 53 A. Terrain Clutter ..... ...

1977-10-01

13

Radar Analysis of a Tamex Frontal System  

Science.gov (United States)

... 24 1.6. Storm Movement .. .. . ... W hydrometeor fall speed containing the vertical velocity and the particle terminal fall speed (= w + V) ...

1989-08-01

14

Modeling and Control of Airport Queueing Dynamics under Severe ...  

Science.gov (United States)

air traffic controllers at BOS tower and Terminal Radar Ap- .... Runway ) @ Runway. Buffer. Queue. Runway. Stochastic Delay. (M/1 server). (Runway to Fix). ,I, ...

15

INTERPRETATION OF RADAR DATA FROM THE ICY GALILEAN SATELLITES AND ...  

Science.gov (United States)

(1989], however, we modeled the phase using a sum of simple power law terms. We. chose to do our work on Triton's atmosphere using the exponential functions ...

16

April 15 02 - NASA  

Science.gov (United States)

Nov 13, 2006 ... Indicator Experiment (TIE) consists of a wideband sensor to gather radar, ... November 10 at Shore Memorial. Hospital in Nassawadox, Va. ...

17

Aircraft measurements of asymmetric temperature microstructure causing azimuth variations of VHF radar echo power  

British Library Electronic Table of Contents (United Kingdom)

VHF wind-profiling radars often measure a decrease of echo power with zenith angle, which can be explained from in situ measurements of horizontal layering or anisotropy of metre-scale temperature structure in the atmosphere. There can also be an azimuthal variation of echo power, which is increased in an azimuth opposite to the vertical shear vector of horizontal wind. This paper checks if the azimuth variation can also be linked to in situ observations of temperature structure, using aircraft flights in the tropopause region near a VHF radar. At heights where VHF radar measures wind shear and aspect sensitivity, there can be an asymmetry in the probability distribution of horizontal gradient of potential temperature, for horizontal scale of e.g. hundreds of metres. The asymmetry is often...

2007-01-01

18

A Great Day to Go Flying  

Science.gov (United States)

but one test point on the flight cards was achieved before we hit our "bingo," or minimal fuel remaining, and we had to land. The radar was developed by NASA's Jet Propulsion...

2011-10-07

19

ALOS satellite imagery utilizations for safeguards  

International Nuclear Information System (INIS)

This paper introduces examples of satellite imageries analysis and utilizations for safeguards activities. Recently, many kinds of satellite imageries are available in the world i.e., high-spatial resolution, multi- and hyper-spectral, multi-function, and multi-polarization radars. The problem is that how to obtain the required information from these digital images. The Japan Aerospace Exploration Agency (JAXA) has successfully launched the Advanced Land Observing Satellite (ALOS, the nickname is 'Daichi') on 24th January, 2006. The mission objectives are cartography, regional observation, disaster monitoring etc. ALOS has three instruments, PRISM, AVNIR-2, and PALSAR, to achieve these objectives. An overview of ALOS is provided. ALOS follows the Japanese Earth Resources Satellite- 1 (JERS-1) and the Advanced Earth Observing Satellite (ADEOS) and utilizes advanced land-observing technology. ALOS is fling in a Sun-synchronous orbit with an inclination angle of 98.16 ...

2006-10-16

20

Wind energy mapping of coastal zones by synthetic aperture radar (SAR) for siting potential windmill locations  

Energy Technology Data Exchange (ETDEWEB)

The authors propose using synthetic aperture radar(SAR) for wind energy mapping of coastal zones. The SAR equipment is located on the European Space Agency ERS-1 and 2 and the RADARSAT satellites. Examples of wind energy maps and evaluations of their applications are given for the Norwegian west coast.

2000-07-01

21

Microwaves - the hidden danger. Mikrowellen - die verheimlichte Gefahr  

Energy Technology Data Exchange (ETDEWEB)

Today, highly frequent radio waves are regarded as undangerous to man. Diseases seen at radar-technicians during the 2nd World War, however, indicated that microwaves applied in radar systems were hazardous to health. The Russian work medicine has been knowing microwave-caused hazards in industry since the beginning of the thirties. Therefore in some East-European countries there are terms of protection and severe norms of safety for the staying of persons in the radiation sphere of microwaves.

1987-01-01

22

TEENET Cleaner Production Databases  

Wastenet

...of stations and a number of components, and meta information on air quality monitoring networks and stations. Access the database Producer Europe Environment Agency Content ...of stations and a number of components, and meta information on air quality monitoring networks and stations. Coverage National (Europe) Number of records...

24

Signal and imaging sciences workshop proceedings  

Energy Technology Data Exchange (ETDEWEB)

Papers are presented in the areas of: Medical Technologies; Non-Destructive Evaluation; Applications of Signal/Image Processing; Laser Guide Star and Adaptive Optics; Computational Electromagnetic, Acoustics and Optics; Micro-Impulse Radar Processing; Optical Applications; TANGO Space Shuttle.

1997-11-01

25

Measurements of Spectral Characteristics of Swimmer Targets ...  

Science.gov (United States)

... 3.0 Radar Measurements 3-1 3. 1 Spectral Density Measurements 3-2 3. 1. 1 System Calibration 3-3 ... 3. 1 SPECTRAL DENSITY MEASUREMENTS ...

1974-05-01

26

Identification of a distant cis-regulatory element controlling pharyngeal arch-specific expression of zebrafish gdf6a/radar  

UK PubMed Central (United Kingdom)

Skeletal formation is an essential and intricately regulated part of vertebrate development. Humans and mice deficient in Growth and Differentiation Factor 6 (Gdf6) have numerous...Full Text Available

2010-04-01

27

Earth Resources NASA SP-7041 (18) - NASA Technical Reports Server  

Science.gov (United States)

The Grover S and X-band dual-wavelength radar system has been ...... A. H. Watkins (U.S. Geological Survey, Earth Resources. Observation Systems Data Center ...

28

Station Crew Wishes Buzz Aldrin Luck On 'Dancing'  

National Aeronautics and Space Administration (NASA)

International Space Station astronauts Jeff Williams and T.J. Creamer wish Buzz Aldrin luck on

2010-03-17

29

Using ERS-2 SAR images for routine observation of marine pollution in European coastal waters  

Energy Technology Data Exchange (ETDEWEB)

More than 660 synthetic aperture radar (SAR) images acquired over the southern Baltic Sea, the North Sea, and the Gulf of Lyon in the Mediterranean Sea by the Second European Remote Sensing Satellite (ERS-2) have been analyzed since December 1996 with respect to radar signatures of marine pollution and other phenomena causing similar signatures. First results of our analysis reveal that the seas are most polluted along the main shipping routes. SAR images acquired during descending (morning) and ascending (evening) satellite passes show different percentages of oil pollution, because most of this pollution occurs during night time and is still visible on the SAR images acquired in the morning time. Moreover, we found a higher amount of oil spills on SAR images acquired during summer (April-September) than on SAR images acquired during winter (October-March). We attribute this finding to the higher mean wind speed encountered in all three test ...

1999-09-30

30

The German Army and its management of hazards and hazardous substances. Report of the working group Dr. Sommer  

International Nuclear Information System (INIS)

This report primarily deals with three issues: the health consequences of the use of ammunition with depleted uranium cores; the health damage that radar staff may have suffered through stray X-radiation; and the way hazardous materials such as asbestos are handled in the German army. As regards uranium ammunition, the present findings suggest that there is neither reason for concern nor blame on anyone. The 31,000 American DU rounds that were fired over Kosovo in 1999 neither pose a health hazard to soldiers nor to the civil population. All that remains is a minimal risk of future groundwater contamination. The radar equipment currently in use in the German army poses no danger to operators, inspectors, service personnel or instructors provided that the relevant safety rules are observed. However, this cannot be said with the same degree of certainty with regard to the equipment used in the 1960s and 1970s. It is quite possible that ...

31

Reverse time migration for ground penetrating radar using finite difference time domain method; Jikan ryoiki yugenn sabunho ni yoru chichu reda no ribasu taimu maigureshon  

Energy Technology Data Exchange (ETDEWEB)

The reversion time migration, as one of reflection seismic prospecting migration, reverse propagates a wave equation by reverse promoting the differential time, and conducts the migration. The method has such merits as no limit to the inclined angle of a reflection, correspondence to a complex topography etc. And, there is a finite difference time domain (FDTD) that uses the Maxwell equation as it is and makes a difference approximation in the methods differentiating and resolving electro-magnetic fields. It is also possible to apply the reverse time migration onto it. In this speech, using an explosive reflection face, a slope 2 layer structure and models of its reflection points are synthesized by a ground penetrating radar using the FDTD, and reverse time migration is conducted. As a result, it is clarified that the reverse time migration is valid for the ground penetrating radar recording. And, the cases including a diffusion item in the ...

1999-02-01

32

GeoSAR program: IFSAR validation and terrain classification from polarimetry  

Science.gov (United States)

The GeoSAR (geographic synthetic aperture radar) program is a Defense Advanced Research Projects Agency (DARPA) sponsored program organized in cooperation with the Jet Propulsion Laboratory (JPL) and the California Department of Conservation. Some aspects of the program have been existent for almost two years. The technical goal of the program has been the development of rapid-mapping radar technologies, and has now, as its principal challenge, the development of a capability for terrain mapping under foliage. In this paper, we discuss validation of current technology and examine the utility of data products currently produced by the Environmental Research Institute of MIchigan's (ERIM) IFSARE, JPL's TOPSAR, and JPL's AIRSAR. We find that ERIM's X-band IFSARE system produces elevation maps to better than 2-m accuracy. Based on this we determine that TOPSAR elevation maps are accurate to at least 5 m. We also demonstrate the utility of JPL's ...

1996-06-01

33

Algorithmic aspects and supercomputing trends in computational electromagnetics  

Energy Technology Data Exchange (ETDEWEB)

Accurate and rapid evaluation of radar signature for alternative aircraft/store configurations would be of substantial benefit in the evolution of integrated designs that meet RCS requirements across the threat spectrum. Finite-volume time domain methods offer the possibility of modeling the whole aircraft, including penetrable regions and stores, at longer wavelengths on today's supercomputers and at typical airborne radar wavelengths on the teraflop computers of tomorrow. A structure-grid finite-volume time domain CFD based RCS code has already been developed at the Rockwell Science Center, and this code incorporates modeling techniques for general radar absorbing materials and structures. Using this work as a base, the goal of the CFD based CEM effort is to define, implement, and evaluate various code development issues suitable for rapid prototype signature prediction addressing many issues related to physics ...

1993-01-01

34

central sports - NASA  

Science.gov (United States)

11 matches ... 04.17.2002. International Space Station Sports a New Truss + More Details. 04.17 .2002. International Space Station Sports a New Truss ...

35

Target stations and beam dumps for the CERN SPS  

International Nuclear Information System (INIS)

The design of the absorber blocks for internal and external dumping of the SPS proton beam is discussed. In addition, the external target stations for slow and fast extracted proton beams are described.

1977-03-16

36

Robonaut 2 Makes First Motions on Station  

National Aeronautics and Space Administration (NASA)

Robonaut 2 goes through a series of tests aboard the International Space Station, including its first motions on the orbital outpost. n

2011-10-14

37

Previous - Global Change Master Directory (GCMD)  

Science.gov (United States)

The automatic weather stations at the Australian stations (Casey, Davis, ... This metadata record describes Simone Ingham's survey of vegetation sampling ...

38

Monthly electricity usage at Australian Antarctic Stations - NASA  

Science.gov (United States)

Record Search Query: Science Keywords>HUMAN DIMENSIONS>INFRASTRUCTURE> ELECTRICITY. Monthly electricity usage at Australian Antarctic Stations ...

39

GIS for combined storage and analysis of data from terrestrial and synthetic aperture radar remote sensing deformation measurements in hard coal mining  

British Library Electronic Table of Contents (United Kingdom)

In this paper we demonstrate the capabilities of our ArcGIS-based software development that includes an adapted database system and a GIS tool for storage, combined analysis and visualization of leveling data and interferometric synthetic aperture radar (SAR) deformation measurements. Preprocessed remote sensing image data are stored with metadata that include all processing routines and parameters. This allows reproduction and traceability of all processing steps. Deformation monitoring is supported through data searching and selection based on a variety of criteria. A methods toolbox allows spatio-temporal analyses for points, lines and areas (e.g. subsidence basins) in a graphical manner.

2011-01-01

40

A wave effect enabling universal frequency scaling, monostatic passive radar, incoherent aperture synthesis, and general immunity to jamming and interference  

CERN Document Server

A fundamental Doppler-like but asymmetric wave effect that shifts received signals in frequency in proportion to their respective source distances, was recently described as means for a whole new generation of communication technology using angle and distance, potentially replacing TDM, FDM or CDMA, for multiplexing. It is equivalent to wave packet compression by scaling of time at the receiver, converting path-dependent phase into distance-dependent shifts, and can multiply the capacity of physical channels. The effect was hitherto unsuspected in physics, appears to be responsible for both the cosmological acceleration and the Pioneer 10/11 anomaly, and is exhibited in audio data. This paper discusses how it may be exploited for instant, passive ranging of signal sources, for verification, rescue and navigation; incoherent aperture synthesis for smaller, yet more accurate radars; universal immunity to jamming or interference; and precision frequency scaling of ...

2008-01-01

41

1982 International Geoscience and Remote Sensing Symposium, Munich, West Germany, June 1-4, 1982, Digest. Volumes 1 and 2  

Energy Technology Data Exchange (ETDEWEB)

Theoretical and experimental data which have defined and/or extended the effectiveness of remote sensing operations are explored, with consideration given to both scientific and commercial activities. The remote sensing of soil moisture, the sea surface, and oil slicks is discussed, as are programs using satellites for studying geodynamics and geodesy, currents and waves, and coastal zones. NASA, Canadian, and Japanese radar and microwave passive and active systems are described, together with algorithms and techniques for image processing and classification. The SAR-580 project is outlined, and attention is devoted to satellite applications in investigations of the structure of the atmosphere, agriculture and land use, and geology. Design and performance features of various optical scanner, radar, and multispectral data processing systems and procedures are detailed.

1982-01-01

43

The characteristic and relevant fault analysis for the microgovernor synchronization of Daya Bay Nuclear Power Station and Ling'ao Nuclear Power Station  

International Nuclear Information System (INIS)

In Daya Bay and Ling'ao Nuclear Power Station, the Microgovernor has the control functions such as synchronization, block loading etc. The control principle of the Microgovernor is right described by sequence diagram for the first time. That the fault occurred in the synchronization process of Daya Bay Nuclear Power Station unit 1 is also analyzed and illustrated. (author)

2005-09-01

45

ISS Update - Oct. 19, 2011  

National Aeronautics and Space Administration (NASA)

The International Space Station video update for Oct. 19, 2011.

2011-10-19

46

ISS Update - Oct. 18, 2011  

National Aeronautics and Space Administration (NASA)

The International Space Station video update for Oct. 18, 2011.

2011-10-18

47

ISS Update - Oct. 17, 2011  

National Aeronautics and Space Administration (NASA)

The International Space Station video update for Oct. 17, 2011.

2011-10-17

48

ISS Update - Oct. 14, 2011  

National Aeronautics and Space Administration (NASA)

The International Space Station video update for Oct. 14, 2011.

2011-10-14

49

ISS Update - Oct. 13, 2011  

National Aeronautics and Space Administration (NASA)

The International Space Station video update for Oct. 13, 2011. n

2011-10-13

54

Proceedings of the twelfth international conference, applied geologic remote sensing. Practical solutions for real-world problems  

Energy Technology Data Exchange (ETDEWEB)

The topics covered at the conference include: mineral exploration; geological mapping/stratigraphy; environmental monitoring and hydrology; petroleum exploration; radar digital elevation mapping; new commercial remote sensing initiatives; geological hazards and engineering; processing and integration techniques; and hyperspectral geology.

1997-12-31

55

Oil and the future: Taking bearings in the greenhouse in a post Brent Spar world  

Energy Technology Data Exchange (ETDEWEB)

The paper discusses future oil combustion. A greenhouse-related environmental driving-force seems set to emerge in the capital markets in the years ahead. This will severely compound other already serious environment-related financial problems blighting the oil-industry`s access to capital radar screen. The wise oil company is now, increasingly clearly, the company thinking about how to begin repositioning itself for the twenty-first century as a total energy company. 6 refs.

1995-12-31

56

Mission Science Calibration and Validation Plan - SMAP  

Science.gov (United States)

Nov 16, 2010 ... In situ observations are usually made point-wise and the problem in using ...... also discussion of adaptive filtering in Section 4.1.2 of the L4_SM ...... L2-SR -265 SMAP shall provide a Level 1C radar sigma-0 product ...

57

Microwaves (including RADAR) and radiation protection  

Energy Technology Data Exchange (ETDEWEB)

The Commission of the European Communities has submitted a directive for the protection against microwaves. According to this directive, exposures above the upper limit established for the protection of individuals and the general population are permissible only if the respective individuals are required to submit to occupational medical control. An introductory overview is presented giving information on microwaves, applied techniques and available protective means.

1981-02-01

58

A passion for physics  

Energy Technology Data Exchange (ETDEWEB)

This is an account of the initial struggles and subsequently successful career of a young woman growing up in prewar Australia with the overriding desire to become a physicist despite various problems and prejudices. The book provides first-hand accounts of wartime radar research and development in Australia; the immediately post-war era in nuclear physics at the Cavendish Laboratory, Cambridge; and work in the Nuclear Physics Division at AERE Harwell in the period from the 1950s onwards. (UK).

1991-01-01

59

Water resources data for Texas, water year 1993. Volume 3. Colorado River basin, Lavaca River basin, Guadalupe River basin, Nueces River basin, Rio Grande basin, and intervening coastal basins. Water-data report (Annual), 1 October 1992-30 September 1993  

Energy Technology Data Exchange (ETDEWEB)

Water-resources data for the 1993 water year for Texas are presented in four volumes, and consist of records of stage, discharge, and water quality of streams and canals; and stage, contents, and water quality of lakes and reservoirs; and water levels and water quality of ground-water wells. Volume 3 contains records for water discharge at 134 gaging stations; stage only at 1 gaging stations; stage and contents at 13 lakes and reservoirs; water quality at 81 gaging stations; and data for 30 partial-record and 4 flood-hydrograph partial-record stations. Also included are lists of discontinued surface-water discharge or stage-only stations and discontinued surface-water-quality stations; crest-stage and flood-hydrograph partial-record stations, reconnaissance partial-record stations, and low-flow partial-record ...

1994-03-01

60

Identification of water quality and benthos characteristics in Daya Bay, China, from 2001 to 2004  

British Library Electronic Table of Contents (United Kingdom)

Physicochemical and benthos data were collected from 12 marine monitoring stations in Daya Bay, during 2001-2004. 12 stations in Daya Bay could be grouped into three clusters: cluster I consisted of stations in the southern part of Daya Bay (stations S1, S2 and S6); cluster II consisted of stations in the cage culture areas (stations S3, S4, S5 and S8); cluster III consisted of stations in the southwest, the middle and the northeast of the Bay (stations S7, S9, S10, S11 and S12). Calculation with bivariate correlations between benthos and major physicochemical factors showed that the density of benthos in all stations correlated positively with temperature, DO, pH, NH4-N, SiO3-Si, SiO3-Si /PO4-P and chlorophyll a and was negatively correlated with salinity, Secchi, COD, NO3-N, NO2-N, TIN, ...

2011-01-01

61

Significant Treatment: An Assessment of Issues-Programs List Availability in Missouri Radio Station Public Inspection Files  

British Library Electronic Table of Contents (United Kingdom)

Over the past three decades, rising competition from television and other new media prompted the FCC to ease the responsibilities of radio stations to maintain extensive records of issues programming, while retaining the responsibility of stations to provide ready public access to records. This study investigated the availability of Issues-Programs Lists in nearly 100 Missouri radio station Public Files. One in five randomly sampled stations failed to produce access to Lists upon demand as required under federal law. Noncompliance themes include: Inability to access Public Files within 20 minutes of face-to-face requests; station personnel with limited or no knowledge of Files; denial of access to Files and Lists (i.e., verbal refusals, locked studio doors); and incomplete Files. The rate ...

2007-01-01

62

Control Centre operations as the focus for building station teamwork - issues and resource impacts  

Energy Technology Data Exchange (ETDEWEB)

Effective teamwork among station work groups is essential for plant production and safety in all phases of plant operation. To achieve effective teamwork, all contributing work groups must have ongoing access to and share a common perspective on station work priorities, and recognize how their individual contributions fit with and support the contributions of other groups in support of the larger station goals. Achieving and maintaining this alignment in perspective across all workgroups can be a challenge in large organizations. This paper discusses the experience at Darlington in building and maintaining station teamwork among the station workgroups in support of day-to-day plant operations. The issues encountered and the resource impacts of specific teamwork supporting practices adopted are outlined. (author)

2006-07-01

63

Survey of Flue Gas Desulfurization Systems: Bruce Mansfield Station, Pennsylvania Power Co.  

Science.gov (United States)

This report gives the results of a survey of operational flue gas desulfurization (FGD) systems on coal-fired utility boilers in the United States. The FGD systems installed on Units 1 and 2 at the Bruce Mansfield Station of the Pennsylvania Power Company...

1979-01-01

64

Peter Frampton Talks to Station Crew  

National Aeronautics and Space Administration (NASA)

Rocker Peter Frampton and his band are introduced by astronaut Ron Garan to Commander Mike Fossum and Flight Engineers Satoshi Furukawa and Sergei Volkov aboard the International Space Station during a visit to Mission Control in Houston.

2011-10-17

65

Design and construction progress on Gentilly 2, Cordoba, Point Lepreau, and Wolsung projects  

International Nuclear Information System (INIS)

Gentilly 2, Point Lepreau, Cordoba and Wolsung are the first 600 MW CANDU nuclear generating stations to be built. Progress in their construction and in the remaining design work for these stations is discussed. (LL).

1980-06-18

66

Chalk Point Cooling Tower Project: Chalk Point Meteorological Station Report. Volume II.  

Science.gov (United States)

This report documents the operation, maintenance, calibration, data acquisition and data reduction at the Chalk Point Meteorological Station for the period November 15, 1978 through November 15, 1979. Climatological data summaries for each month and calib...

1979-01-01

67

Astronaut Jeff Williams Answers Your Questions  

National Aeronautics and Space Administration (NASA)

Expedition 22 Commander Jeff Williams, aboard the International Space Station 220 miles above Earth, responds to questions posted on YouTube concerning the station's orientation, life in space and the recent butterfly experiment.

2010-03-10

68

Synthetic aperture radar image of agricultural fields with surface drainage network: simulation and spatial information retreival  

Science.gov (United States)

We develop a 3-D model to simulate the synthetic aperture radar (SAR) image formation process of an undulated vegetation canopy such as corn grown in fields with large periodic drainage reliefs. We explain how the simulated SAR image of undulated vegetation medium is obtained by the convolution of a 2-D slice of the 3-D simulated SAR system point spread function [(PSF), emulating the SAR beam modeled by a cosine modulated Gaussian], with the 2-D projection of the observed undulated vegetation canopy (modeled with scatterers randomly distributed in 3-D undulated space) followed by the extraction of each look envelope, the summation of looks, and sampling in azimuthal and range directions. Our model is useful to study the parameters involved in the formation and the analysis of SAR images of undulated vegetation medium. Validation of simulations made with actual SAR images shows that undulated corn crop canopies are well characterized by the mean contrast of the ...

2001-10-01

69

One-class classifiers and their application to synthetic aperture radar target recognition  

Energy Technology Data Exchange (ETDEWEB)

Target recognition requires the ability to distinguish targets from non-targets, a capability called one-class generalization. To function as a one-class classifier, a neural network must have three types of generalization: within-class, between-class, and out-of-class. We discuss these three types of generalization and identify neural network architectures that meet these requirements. We have applied our one-class classifier ideas to the problem of automatic target recognition in synthetic aperture radar. We have compared three neural network algorithms: Carpenter and Grossberg`s algorithmic version of the Adaptive Resonance Theory (ART-2A), Kohonen`s Learning Vector Quantization (LVQ), and Reilly and Cooper`s Restricted Columb Energy network (RCE). The ART 2-A neural network has given the best results, with 100% within-class, and out-of-class generalization. Experiments show that the network`s performance is sensitive to vigilance and number of training set ...

1992-10-01

70

Coal-mine-hazard detection using in-seam ground-penetrating-radar transillumination. Report of Investigations/1987  

Energy Technology Data Exchange (ETDEWEB)

The Bureau of Mines recently completed peliminary studies to demonstrate the feasibility of using Ground-Penetrating Radar (GPR) for in-seam hazard detection. Investigations included air and coal tests for the purpose of checking equipment accuracy, coal penetration, and other factors such as the effects of receiver orientation. Further investigations involved using both a short pulse and a new prototype synthetic-pulse system to locate a clay vein in a coal seam using transillumination. Data were gathered on multiple travel paths, and a back-projection processing technique was then used to create a tomographic image using the calculated velocities. A computer model of the same coal seam was subsequently processed using the same tomogrpahic technique, and the results were compared with those of the actual data. Results of these preliminary studies show that GPR is feasible for use in in-seam hazard detection and point the direction that future research should take.

1987-01-01

71

Weekly ISS Recap - Oct. 10-14, 2011  

National Aeronautics and Space Administration (NASA)

The weekly International Space Station video recap for Oct. 10-14, 2011.

2011-10-14

77

Analysis and evaluation for little branch of Daya Bay Nuclear Power Station based on vibration test result  

International Nuclear Information System (INIS)

During the operation of Daya Bay Nuclear Power Station, some little branches of secondary system were with great vibration and even some of them cracked due to the great vibration that may cause some effect on the safety of the power station. This paper performed analysis and evaluation to the eight systems of Daya Bay Nuclear Power Station based on the vibration test results from the examination of the safety during ten years, and the list of the sensitive piping and suggestion for modification were presented based on the analysis results. (authors)

2007-06-01

78

Rapid Tools for Joint Inversion and Imaging. Final report  

Energy Technology Data Exchange (ETDEWEB)

The activities and results of a Small Business Innovation Research Phase II project entitled ''Rapid Tools for Joint Inversion and Imaging'' are presented. Research and development on three-dimensional methods to recover distributions of material property values from sparse data are reported. Innovations using artificial neural networks and extended Kalman filtering are described. The report also covers investigations on upscaling and downscaling, segmentation for data processing, and applications to ground penetrating radar and geohydraulic tomography.

2000-08-02

79

Micropulse Lidar (MPL) Handbook  

Energy Technology Data Exchange (ETDEWEB)

The micropulse lidar (MPL) is a ground-based optical remote sensing system designed primarily to determine the altitude of clouds overhead. The physical principle is the same as for radar. Pulses of energy are transmitted into the atmosphere; the energy scattered back to the transceiver is collected and measured as a time-resolved signal. From the time delay between each outgoing transmitted pulse and the backscattered signal, the distance to the scatterer is infered. Besides real-time detection of clouds, post-processing of the lidar return can also characterize the extent and properties of aerosol or other particle-laden regions.

2006-05-01

80

Computer model of high-latitude scintillation. [WBMOD program  

Energy Technology Data Exchange (ETDEWEB)

The DNA Wideband satellite experiment provided extensive data on scintillation produced in high-altitude structured plasmas. A computer program, WBMOD, is being developed to summarize those data in an applications-oriented way. The program contains the phase-screen scattering theory of Rino and a morphological description of ionospheric irregularities (thus far only at auroral latitudes) based on Wideband observations. It permits a user to compute scintillation indices for both phase and intensity as a function of system operating parameters and solar-ionospheric disturbance level. Correction is made for multiple scatter, and the user may choose either one-way (communication) or two-way (radar) propagation.

1982-01-01

81

Computer model of high-latitude scintillation  

International Nuclear Information System (INIS)

The DNA Wideband satellite experiment provided extensive data on scintillation produced in high-altitude structured plasmas. A computer program, WBMOD, is being developed to summarize those data in an applications-oriented way. The program contains the phase-screen scattering theory of Rino and a morphological description of ionospheric irregularities (thus far only at auroral latitudes) based on Wideband observations. It permits a user to compute scintillation indices for both phase and intensity as a function of system operating parameters and solar-ionospheric disturbance level. Correction is made for multiple scatter, and the user may choose either one-way (communication) or two-way (radar) propagation.

82

Calculation of ice accumulation rates in Antarctica over the last glacial cycle.  

Environmental Research Database

DescriptionRates of ice accumulation in Antarctica are not known well, yet they are fundamental to assessing the ice sheet mass balance. Past accumulation rates are less well defined. We are in a unique position to provide detailed accounts of accumulation in Antarctica. We will measure isochronous internal layering across the ice sheet, which can be readily identified in radar data that we hold. Internal layers will be traced to ice-cores (allowing dating) and across wide regions of the ice sheets. A nume [continued...

2006-01-08

83

Stretch-out operation and extended low power operation in Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

Stretch-Out and Extended Low Power Operation is two particular operating modes applied for nuclear electricity generation. The relevant safety analysis and the impacts on plant operation are well illustrated, as well as some operation experiences earned in Daya Bay nuclear power station. The safety analysis and plant practice show that Stretch-Out operation and Extended Low Power Operation are operable in Daya Bay nuclear power station

2002-10-01

84

Station set residual : event classification using historical distribution of observing stations.  

Science.gov (United States)

Analysts working at the International Data Centre in support of treaty monitoring through the Comprehensive Nuclear-Test-Ban Treaty Organization spend a significant amount of time reviewing hypothesized seismic events produced by an automatic processing system. When reviewing these events to determine their legitimacy, analysts take a variety of approaches that rely heavily on training and past experience. One method used by analysts to gauge the validity of an event involves examining the set of stations involved in the detection of an event. In particular, leveraging past experience, an analyst can say that an event located in a certain part of the world is expected to be detected by Stations A, B, and C. Implicit in this statement is that such an event would usually not be detected by Stations X, Y, or Z. For some well understood parts of the world, the absence of one or more 'expected' ...

2010-04-01

85

Perspectives on energy storage wheels for space station application  

Energy Technology Data Exchange (ETDEWEB)

Several of the issues of the workshop are addressed from the perspective of a potential Space Station developer and energy wheel user. Systems considerations are emphasized rather than component technology. The potential of energy storage wheel (ESW) concept is discussed. The current status of the technology base is described. Justification for advanced technology development is also discussed. The study concludes that energy storage in wheels is an attractive concept for immediate technology development and future Space Station application.

1984-11-01

86

Introduction to the RCS thermal-hydraulic model of the full scope simulator of Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

Both the accuracy and real-time are quite strictly required for the RCS thermal-hydraulic model of the simulation of nuclear power station. So, a large amount of reasonable simplifications should be carried on. The author introduces the RCS thermal-hydraulic model of the full scope simulator of Daya Bay Nuclear Power Station, and emphasizes on the fundamental hypotheses and computation method of its kernel part--DEFI programme.

87

In-core reload design for Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

The in-core reload design procedure, computer codes, design contents and comparison between expected design values and measured values for Daya Bay Nuclear Power Station are presented. The in-core reload design for Daya Bay Nuclear Power Station performed by Nuclear Power Institute of China satisfies the requirements of safety and economy. The expected design values are fit well with measured values

2000-12-05

88

Fuel management study on 18 months fuel cycle for Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

The fuel management study on 18-months fuel cycle project is introduced for Daya Bay Nuclear Power Station. Station from the selection of the objective of fuel management for 18-months cycle, the method used and the analysis done are explained in detail to reach the final loading pattern chosen

2002-10-01

89

Exploration and practice on contract management of Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

In the market economy, Daya Bay Nuclear Power Station needs to out source or allow to suppliers among industries, while concentrating its core competitive capability, for safely and stable operation. By evaluating the features of contract management in Daya Bay Nuclear Power Station, set up the organization and process of the supply management

2002-02-01

90

Electrical equipment of the Marchtrenk power station on the river Traun  

Energy Technology Data Exchange (ETDEWEB)

By way of introduction, the author describes the electrical equipment of the power station on the River Traun and then lists the main features of the electrical systems such as generators, transformers, the power transmission systems as, e.g., the generator leads, the 8 kV switch plant, the 110 kV oil-filled cable as well as the station-service, control, protection and monitoring systems. The control of the headwater level and of the mechanical systems of the barrage is described in detail.

1982-03-01

91

Core power distribution measurement and data processing in Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

For the first time in China, Daya Bay Nuclear Power Station applied the advanced technology of worldwide commercial pressurized reactors to the in-core detectors, the leading excore six-chamber instrumentation for precise axial power distribution, and the related data processing. Described in this article are the neutron flux measurement in Daya Bay Nuclear Power Station, and the detailed data processing.

92

Cause trending analysis for licensing operational events in Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

The human causal factors for all human error licensing operational events on Daya Bay nuclear power station since 1993 to 2003 are categorized, the trend of these causal factors is analyzed. The emphasis is placed on analyzing the deficiencies on complying with and executing regulations and procedures. The results provide directional reference for nuclear power station to improve human performance. (author)

2005-09-01

93

Water resources data for Minnesota, water year 1993. Volume 2. Upper Mississippi and Missouri River basins. Water-data report (Annual), 1 October 1992-30 September 1993  

Energy Technology Data Exchange (ETDEWEB)

Water-resources data for the 1993 water year for Minnesota consists of records of stage, discharge and water quality of streams; stage, contents, and water quality of lakes and reservoirs; and water levels and water quality in wells and springs. This volume contains discharge records for 58 gaging stations; stage and contents for 9 lakes and reservoirs; water quality 15 stream stations, 1 lakes station, 1 precipitation station, and water levels for 15 observation wells. Also included are 61 high-flow partial-record stations. Additional water data were collected at various sites, not part of the systematic data collection program and are pulished as miscellaneous measurements.

1994-07-01

94

Water resources data for Minnesota, water year 1991. Volume 2. Upper Mississippi and Missouri River Basins. Water-data report (Annual), 1 October 1990-30 September 1991  

Energy Technology Data Exchange (ETDEWEB)

Water-resources data for the 1991 water year for Minnesota consist of records of stage, discharge and water quality of streams; stage, contents, and water quality of lakes and reservoirs; and water levels and water quality in wells and springs. The volume contains discharge records for 60 gaging stations; stage and contents for 9 lakes and reservoirs; water quality for 18 stream stations, 1 lake station, 22 partial-record sites, 1 precipitation station, 108 wells; and water levels for 119 observation wells. Also included are 59 high-flow partial-record stations. Additional water data were collected at various sites, not part of the systematic data collection program and are published as miscellaneous measurements or low-flow investigations.

1992-09-01

95

Design modifications in radiation monitoring system at Tarapur Atomic Power Station 3 and 4  

International Nuclear Information System (INIS)

Inputs on radiological conditions forms the basis of implementation of effective exposure control to plant personnel in nuclear power station. Radiation monitoring system provides this input to the plant operator as well as to health physics group. Several design modifications have been incorporated in the Radiation Monitoring System at Tarapur Atomic Power Station (TAPS 3 and 4) over the similar systems at Kakrapar Atomic Power Station (KAPS) and Kaiga Generating Station (KGS). The radiological monitoring systems installed at TAPS unit 3 and 4 includes on line Radiation Data Acquisition System (RADAS), Emergency sampling system, effluent monitoring system and environmental monitoring system. The design changes and the versatile use of these systems are presented in this paper. (author)

2006-11-13

96

Cost and sensitivity analysis for photovoltaic station in Kuwait  

Energy Technology Data Exchange (ETDEWEB)

A full analysis is shown in this paper for the cost of kWh generated from photovoltaic station located in Kuwait. By using a 21 years weather data for Kuwait, the yearly generated energy was found by proposing the PV station capacity with known panels tilt angle. The cost of kWh generated from PV station was compared with the kWh generated from conventional units in the country. A sensitivity analysis was done to some factors, capital cost per installed PV peak watt, discount rate, and operating peak hours, which affect the cost of kWh production from both PV and conventional units. If the PV station is proposed to be installed in Kuwait, the capital cost per PV installed peak watt must be less than today`s prices. (author)

1996-05-01

97

Analysis of work-environment data from three army field stations  

Energy Technology Data Exchange (ETDEWEB)

Data from a detailed evaluation of environment conditions in three U.S. Army field stations are presented. Three field stations were evaluated: Kunia, Augsburg, and Berlin. Results from a questionnaire administered to over 600 people at all sites in three job types (operator, analyst, and administrative/other) are given which indicate major concerns with conditions such as temperature, lighting, space, furniture, equipment functioning, and general environmental quality. Physical data obtained from measurements of over 270 work stations indicated the presence of cold temperatures, low light levels, reduced VDT screen contrast, glare, and distracting noises. The report provides the basic data that support the concerns expressed by Headquarters; namely, that field-station personnel perform their jobs under conditions likely to impair their effectiveness. Suggestions for improving conditions are given in a ...

1988-10-01

98

Comparison Between Active and Passive Techniques for Radon Gas and Working Level measurements, El-Allouga Mine, Sinai, Egypt  

International Nuclear Information System (INIS)

Two different techniques were used for measuring Rn-gas concentrations and Working Level (WL) in U-exploration galleries at El-Allouga Mine, Sinai, Egypt. The active techniques used EDA(RDA-200) with calibrated Lucas cell and Tri-Met-372 instruments and passive techniques used four different types of SSNTD. Twenty eight (28) stations inside the studied tunnels were located covering the different environmental conditions. The measurements were carried out during summer time, in the ventilated sector (16 stations), the average tunnel air temperature was 24.4 #+-# 2.2 degree C and relative humidity 38%. In the non-ventilated sector (12 stations), the average tunnel air temperature was 22.2#+-#0.4 degree C and relative humidity 70%. The Rn-gas concentrations using EDA(RDA-200) and calibrated Lucas cell, in the ventilated sector averaged 11.966 p Ci/l, while in the non-ventilated stations averaged 786.21 p ...

2007-04-22

99

Aquatic macroinvertebrates and water quality of Sandia Canyon, Los Alamos National Laboratory, December 1992--October 1993. Status report  

International Nuclear Information System (INIS)

In the summer of 1990, an accidental spill from the TA-3 Power Plant Environment Tank released more than 3,785 liters of sulfuric acid into upper Sandia Canyon. The Biological Resource Evaluation Team (BRET) of EM-8 at Los Alamos National Laboratory (LANL) has collected aquatic samples from the stream within Sandia Canyon since then. These field studies gather water quality measurements and collect macroinvertebrates from permanent sampling sites. An earlier report by Bennett (1994) discusses previous BRET aquatic studies in Sandia Canyon. This report updates and expands Bennett's initial findings. During 1993, BRET collected water quality data and aquatic macroinvertebrates at five permanent stations within the canyon. The substrates of the upper three stations are largely sands and silts while the substrates of the two lower stations are largely rock and cobbles. The two upstream stations are located ...

2004-06-01

100

Evaluating the water quality of the microbasins, La Laucha La Lejia and La Rastrojera using macroinvertebrates as biomarkers, Durania municipality, Norte de Santander Department, Colombia  

International Nuclear Information System (INIS)

From June to September 2004 a water research was carried out in six stations that are located at the following microbasins: La Laucha (S1), La Lejia (S2, S3 and S6) and La Rastrojera (S4 and S5). Those microbasins are localized at the Durania municipality in Norte de Santander Department. This study was carried out in order to evaluate water quality at the microbasins above mentioned using macroinvertebrates as bioindicators. For physical, chemical and microbiological parameters a sample was taken at each station. The results were correlated with biologic parameters and it may be concluded that the station 5 closer to the town of Durania is the most polluted by organic matter and that those stations that belong to the ritral zone are less contaminated. The final result showed that the stations 1. 2. 3. 4 and 6 have conditions that can be classified as very clear to clear water and ...

2008-06-01

101

Water resources data for Oklahoma, water year 1992. Volume 2. Red River Basin. Water-data report (Annual), 1 October 1991-30 September 1992  

Energy Technology Data Exchange (ETDEWEB)

Volume 2 of the water resources data for the 1992 water year for Oklahoma consists of record of stage, discharge, and water quality of streams; stage, contents, and water quality of lakes or reservoirs; and water levels of ground-water well. The report contains discharge records for 136 gaging stations; stage and contents for 31 lakes or reservoirs; water quality for 50 gaging stations. Also included are 61 partial-record or miscellaneous streamflow stations and 28 ground-water sites.

1993-04-01

102

The full scope simulator hardware I/O realization in Daya bay nuclear power station  

International Nuclear Information System (INIS)

The full scope simulator in Daya Bay Nuclear Power Station is imported from THOMSON-CSF company in France. It is a large facility, using digital simulation technology, that simulate the main control room of Daya Bay Nuclear Power Station with the high fidelity. It is used for training operators; system analyzing including operation procedure verification. The input output interface system of the simulator is the bridge of the information exchange between instrumentation and the computer. From the point of view of data transfer, this paper discusses the operation principle of the I/O interface system.

103

Redox potential measurement in the power station  

Energy Technology Data Exchange (ETDEWEB)

By its very nature redox potential measurement is suitable for determining the concentration ratio of a stable redox pair through its interaction with a chemically inert electrode surface but not the absolute concentration of a material. The measured redox potentials agree only rarely with those which are easily calculable theoretically. No individual defined stable redox pair is available in power station water. It is therefore not simply possible to measure definable mixed potentials more precisely. For these reasons redox potential measurement in the power station, as also with other types of water, can no longer be regarded as an indicator, by which it can be established whether oxidizing or reducing materials predominate in the water.

1983-01-01

104

Redox potential measurement in the power station  

International Nuclear Information System (INIS)

By its very nature redox potential measurement is suitable for determining the concentration ratio of a stable redox pair through its interaction with a chemically inert electrode surface but not the absolute concentration of a material. The measured redox potentials agree only rarely with those which are easily calculable theoretically. No individual defined stable redox pair is available in power station water. It is therefore not simply possible to measure definable mixed potentials more precisely. For these reasons redox potential measurement in the power station, as also with other types of water, can no longer be regarded as an indicator, by which it can be established whether oxidizing or reducing materials predominate in the water. (orig.).

105

Elemental concentration analysis in some plant samples by EDXRF at Trabzon  

International Nuclear Information System (INIS)

The elemental analysis of some plant samples have been carried out in Trabzon region (Turkey) using energy-dispersive X-ray fluorescence (EDXRF) spectrometry. We have analyzed plant samples for nine stations using 1.85 GBq 55Fe radioactive sources. We have found that potassium and calcium within 0.3-1.4% and 0.3-2.8% were present in concentration in plants for every station, respectively. The concentration of Cl and Ti generally changed according to the plant species and the sampling station.

2006-12-01

106

Air Shower Events of High-Energy Cosmic Rays Measured at Seoul, South Korea  

Science.gov (United States)

The COsmic ray Research and Education Array (COREA) collaboration has installed an array of six detector stations at two high schools in and near Seoul, Korea for measurement of air-shower events from high-energy cosmic rays. Three stations are installed at each site, where each station consists of four plastic scintillation detectors covering an area of 2m2. In this presentation, we report the currenst status of the COREA project, describing the experimental equipment and measurement of coincident events.

2011-09-01

107

Worldwide Report, Telecommunications Policy, Research and ...  

Science.gov (United States)

... 80 Briefs New Television Transmitter 81 Matadi Satellite Earth Station Inaugurated (Kinshasa AZAP, various dates) 82 Ramazani Marks Opening ...

1985-12-31

108

Waste Food Storage at Fortress Rocks  

Science.gov (United States)

... of waste food generated at McMurdo Station. Some of the difficulties of disposing of waste food ... change waste generation or management at the site? Yes. This will be a temporary waste management ...

109

Underground reservoirs for high-head pumped-storage stations  

Science.gov (United States)

The advantages of using heads of around 1000 m in conjunction with underground location of the lower reservoirs for pumped storage plants are described, and the possible layouts, equipment, and construction methods are discussed.

1973-03-01

110

The Deep Space Network Progress Report 42-39 - NASA Technical ...  

Science.gov (United States)

C. Learning Curve. The learning curve concept has long been recognized and ...... F4. TERMIA. S - STATION EQUIPMENT. V - VLBI VALIDATION EQUIPMENT ...

111

Support required from Canada in the operation and maintenance of CANDU stations overseas  

International Nuclear Information System (INIS)

The long-term support required from Canada in the operation and maintenance of overseas CANDU nuclear generating stations after commercial operation has commenced is described, with reference entirely to the KANUPP reactor. This includes: technical support to station staff to increase plant reliability and maintainability; assistance with plant improvements; procurement of spares and consumables; and assistance with training programmes. This technical support may be provided by a small number of Canadian staff actually resident at the power station; by short-term visits of Canadian specialists to site and by technical and procurement services provided from Canada. Examples of technical problems experienced are given, showing typical services required from Canada.

112

Sun rises on station era - Johnson Space Center - NASA  

Science.gov (United States)

Dec 4, 1998 ... throwing a single switch to as complex as the Spartan deploy and retrieve. ...... The camera, called the Acousto-Optic ...

113

SPACE STATION INTEGRATED WALL DESIGN AND PENETRATION  

Science.gov (United States)

screens of fine wire was placed between the gun barrel and the panel to determine whether the gun performance was repeatable. The transducers were placed ...

114

Rim of the Pacific (RIMPAC). Programmatic Environmental ...  

Science.gov (United States)

... Air Station, Oahu, Kahuku Training Area ... K-Pier, Hawaii, Bradshaw Army Airfield, Hawaii (R&S ... impact area); Makua Military Reservation, Oahu (R&S ...

2002-06-01

116

NASA Sets Launch Dates for Remaining Space Shuttle Missions  

Science.gov (United States)

Jul 7, 2008 ... HOUSTON -- Following a detailed, integrated assessment, NASA selected ... in the center that provides a 360-degree view around the station. ...

117

NASA - Archive  

Science.gov (United States)

equipping the trio of SPHERES on the space station with a Nexus(tm) S handset made by Samsung Electronics and powered by Google's Android(tm) platform. graphic for the NASA mobile...

2011-08-19

118

Metronome to Coordinate the Breaths and Cardiac Compressions Delivered by Minimally-Trained Caregivers During Two-Person CPR  

Science.gov (United States)

Astronaut crew medical officers (CMO) aboard the International Space Station (ISS) receive 40 hours

2005-01-01

119

Johnson News - NASA  

Science.gov (United States)

Nov 21, 2003... for the European Space Agency's Automated Transport Vehicle, a new, uncrewed station cargo vehicle targeted for launch late next year. ...

120

Investigation of thermohydraulic processes in steam generators for nuclear power stations equipped with VVER reactors  

British Library Electronic Table of Contents (United Kingdom)

The results obtained from experimental investigations and mathematical simulation of horizontal steam generators are considered. Recommendations for continuing these works are given.

2006-01-01

121

Direct Detection Optical Intersatelllte Link at 220 Mbps Using ...  

Science.gov (United States)

on this technology has beenproposedas a payload on SpaceStation Freedom to be launched in the near future [1]. Direct detection 4-ary pulse position modula- ...

122

Classes of KWU steam turbines  

International Nuclear Information System (INIS)

For the conversion of thermal energy into electric energy in modern condenser power plants, according to the way of steam generation, two different types of power stations are built: power stations for fossile fuels and nuclear power stations. Also two classes of steam turbines were developed, corresponding to the two power station types, whose steam conditions, by experience and extensive calculations of economy, were determined so that a minimum of power generating cost will result. The two classes, the HMN and the SN series, are composed according to the modular system and designed in such a manner that with a small number of standard components, steam turbines for the power range between 100 and 2,500 MW can be built. (orig.).

123

Alternative Fuel Stations | Department of Energy  

Science.gov (United States)

2011 Department of Energy Investments in Carbon Capture Technologies 2010 Smart Meter Installations DOE Recovery Field Projects and State Memos Advanced Vehicle...

2011-10-08

126

Air pollution in Berlin and its surroundings in 1989. Luftverschmutzung in Berlin und Umgebung im Jahr 1989  

Energy Technology Data Exchange (ETDEWEB)

The report presents details of the distributions of air pollution in the Berlin area and the developments of the past 20 years. Highly polluted areas are indicated in which air pollution reduction measures are particularly urgent. The report therefore intends not only to inform but also to point out the deficiencies of air pollution abatement measures, so that political consequences can be derived and measures can be taken. In all, data were recorded by 39 measuring stations in West Berlin, 16 in East Berlin, and 7 in Potsdam and Frankfurt/Oder. In most stations, sulphur dioxide and airborne dust were measured; 14 stations in West Berlin and one in East Berlin measured carbon monoxide and nitric oxides; 8 stations in West Berlin recorded ozone concentrations. (orig./KW).

1990-10-01

127

54 - IGS  

Science.gov (United States)

Eight units (low-power model Z-12's) were purchased, all for installation at continuously- operating stations in the Los Angeles prototype Dense GPS ...

128

Satellite-based estimates of groundwater storage variations in large drainage basins with extensive floodplains  

British Library Electronic Table of Contents (United Kingdom)

This study presents monthly estimates of groundwater anomalies in a large river basin dominated by extensive floodplains, the Negro River Basin, based on the synergistic analysis using multisatellite observations and hydrological models. For the period 2003-2004, changes in water stored in the aquifer is isolated from the total water storage measured by GRACE by removing contributions of both the surface reservoir, derived from satellite imagery and radar altimetry, and the root zone reservoir simulated by WGHM and LaD hydrological models. The groundwater anomalies show a realistic spatial pattern compared with the hydrogeological map of the basin, and similar temporal variations to local in situ groundwater observations and altimetry-derived level height measurements. Results highlight th...

2011-01-01

129

Satellite remote sensing of Spratly Islands using SAR  

British Library Electronic Table of Contents (United Kingdom)

Spratly Islands, located in the southern part of the South China Sea (SCS), consist of more than 100 small islands, coral reefs and banks. Remote sensing is the only way to obtain a synoptic view of all of the islands in such a large area. It has been demonstrated that satellite synthetic aperture radar (SAR) imagery is a very powerful tool for monitoring meso-scale and small-scale ocean processes in a large area. In this study, satellite SAR images were used to study the ocean environment in the area of Spratly Islands. The aim was to understand the capability of satellite remote sensing to monitor ocean processes and provide information for future field studies. Two sets of high-resolution European Remote Sensing satellite (ERS)-2 SAR images over the entire Spratly Islands area were coll...

2008-01-01

130

Radiation protection - an overview of the concept for radiation protection at work and the concept for environmental radiation protection  

International Nuclear Information System (INIS)

This book gives an overview of the entire field of radiation protection with the subject areas radioactivity, X-rays, UV radiation, laser beams and high-frequency electromagnetic fields. It deals graphically with the most important physical notions, the incidence, origin, properties and biological effects of types of radiation, administrative and practical protection measures and the code of rules governing them. Apart from fundamentals of radiation protection the emphasis on the following: natural radiation exposure, radiation exposure to radon, disaster relief plans in the environment of nuclear plant, the precautionary radiation protection system evolved after Chernobyl, radiation exposure through UV radiation devices, radio, RF communication, radar, microwave ovens and high-voltage transmission lines as well as computer work-places. (orig.).

1993-01-01

131

Interpolating atmospheric water vapor delay by incorporating terrain elevation information  

British Library Electronic Table of Contents (United Kingdom)

In radio signal-based observing systems, such as Global Positioning System (GPS) and Interferometric Synthetic Aperture Radar (InSAR), the water vapor in the atmosphere will cause delays during the signal transmission. Such delays vary significantly with terrain elevation. In the case when atmospheric delays are to be eliminated from the measured raw signals, spatial interpolators may be needed. By taking advantage of available terrain elevation information during spatial interpolation process, the accuracy of the atmospheric delay mapping can be considerably improved. This paper first reviews three elevation-dependent water vapor interpolation models, i.e., the Best Linear Unbiased Estimator in combination with the water vapor Height Scaling Model (BLUE?+?HSM), the Best Linear Unbiased Es...

2011-01-01

132

Integrated method of RS and GPR for monitoring the changes in the soil moisture and groundwater environment due to underground coal mining  

British Library Electronic Table of Contents (United Kingdom)

Mining affects the environment in different ways depending on the physical context in which the mining occurs. In mining areas with an arid environment, mining affects plants? growth by changing the amount of available water. This paper discusses the effects of mining on two important determinants of plant growth?soil moisture and groundwater table (GWT)?which were investigated using an integrated approach involving a field sampling investigation with remote sensing (RS) and ground-penetrating radar (GPR). To calculate and map the distribution of soil moisture for a target area, we initially analyzed four models for regression analysis between soil moisture and apparent thermal inertia and finally selected a linear model for modeling the soil moisture at a depth 10?cm; the relative error o...

2009-01-01

133

Application of remote sensing and geophysics to the detection and monitoring of acid mine drainage  

Energy Technology Data Exchange (ETDEWEB)

The results of a study on the application of remote sensing and geophysical methods for the detection and monitoring of acid mine drainage (AMD) are summarized, with emphasis on those that appear most suitable. The study consisted of a literature review, an information survey of users and suppliers, and discussions with various experts. Space-borne sensors, airborne sensors, airborne videography and digital frame cameras, spectroradiometers, radar, and photographic data are considered. Geophysical methods are effective for measurement of sulphides, areas of active chemical oxidation, acid mine drainage, and contaminated ground water movement. The popularity and effectiveness of various geophysical methods are rated for AMD applications. 25 refs., 1 fig., 3 tabs.

1995-06-01

134

Analysis of Ground Deformation Detected Using the SBAS-DInSAR Technique in Umbria, Central Italy  

British Library Electronic Table of Contents (United Kingdom)

Ground deformation affecting the Umbria region (central Italy) in the 9-year period from 1992 to 2000 was investigated through multi-temporal Differential Synthetic Aperture Radar Interferometry (DInSAR). For the purpose, the Small BAseline Subset (SBAS) technique was adopted, which allows studying the temporal evolution of the detected deformation at two spatial scales: a low-resolution (regional) scale, and a full-resolution (local) scale. For the analysis, SAR data acquired by the European Remote Sensing (ERS-1/2) satellites along ascending and descending orbits were used. The detected deformation was analysed to investigate its relevance to geophysical, geomorphologic, and human-induced processes that may result in hazardous conditions to the population of Umbria. Low-resolution deform...

2009-01-01

135

A program for passively tracking a target using an array of sensors  

Energy Technology Data Exchange (ETDEWEB)

The problem of passively tracking a moving signal source has importance in a variety of applications such as radar, sonar, seismology, and radio astronomy. In many applications, only limited information is available about the signal source. It will be assumed here that only the signals which are detected by the sensors and the velocity of the source signal are known. The objective of this document is to present a program which passively tracks a target using an array of sensors. This program is available in MATLAB, version 3.5. The algorithm which is implemented consists of three main parts: time delay estimation, passive localization, and data post processing. Each of these parts are discussed, and the mathematical foundation for their solution given. Following, this the organization of the program is presented, and an example of its usage is given.

1993-01-01

136

A modular neural network for direction-of-arrival estimation of two sources  

British Library Electronic Table of Contents (United Kingdom)

This work addresses the problem of estimating the direction-of-arrival (DOA) of two sources using an array of sensors. This problem is mostly useful in radar applications, where we have few targets at each range bin. Super-resolution algorithms, such as maximum likelihood (ML) estimation and multiple signal classification (MUSIC), have been applied to this problem, but the former involves high computation efforts, while the later has poor estimation performance for coherent sources. In this work, we propose a DOA estimation network, named RBF-AML, which combines the approximated ML (AML) estimator and a radial basis function (RBF) neural network (NN). In the proposed RBF-AML network, the entire two dimensional DOA space is divided into multiple sectors covered by RBF experts. The AML funct...

2011-01-01

137

The environmental impacts of a large gas-fired combined cycle power station  

Energy Technology Data Exchange (ETDEWEB)

The paper discusses the potential environmental impacts associated with the operation of a large, say 350 MWe, gas-fired combined cycle power station. It concludes that if appropriate control methods are introduced at the design stage of the plant, environmental impacts are minimal and can be considered acceptable. (author).

1991-11-01

138

The computerized management for individual monitoring data in Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

The authors report the individual monitoring data management system (IDOSE) at Daya Bay Nuclear Power Station. The components of the individual monitoring system, the design requirements of IDOSE, the characteristics and application of this computerized management system are mainly presented. Its application shows that IDOSE meets the requirements of the concerning occupational standards of the state and matches with the requirements of IAEA/ISOE.

139

The Atomic Energy Control Board criteria for identification and evaluation of fire hazards in nuclear power stations  

International Nuclear Information System (INIS)

This report presents criteria for the identification and evaluation of fire hazards in nuclear power stations. The report presents criteria that are consistent with the existing regulatory approach in Canada, and outlines engineering tools and analytical techniques currently available to deterministically analyse fire. The criteria presented cover the topics which should be included in a fire hazard analysis and provide details of each topic so that the accuracy of an analysis may be evaluated.

2000-12-10

140

Survey of Flue Gas Desulfurization Systems: Will County Station, Commonwealth Edison Co.  

Science.gov (United States)

The report gives results of a second survey of the flue gas desulfurization (FGD) system on Unit 1 of Commonwealth Edison Co.'s Will County Station. The FGD system, started up in February 1972, uses a limestone slurry in two parallel scrubbing trains. Eac...

1978-01-01

141

Survey of Flue Gas Desulfurization Systems: La Cygne Station, Kansas City Power and Light Co.  

Science.gov (United States)

The report gives results of a second survey of the flue gas desulfurization (FGD) system on Unit 1 of Kansas City Power and Light Co.'s La Cygne Station. The FGD system, first started up in February 1973 and commercially available in June 1973, uses a lim...

1978-01-01

142

Survey of Flue Gas Desulfurization Systems: Cholla Station, Arizona Public Service Co.  

Science.gov (United States)

The report gives results of a second survey of the flue gas desulfurization (FGD) system on Unit 1 of Arizona Public Service Co.'s Cholla Station. The FGD system, commercially available in December 1973, uses a limestone slurry in two parallel scrubbing m...

1978-01-01

143

Survey of Flue Gas Desulfurization Systems, Lawrence Power Station, Kansas Power and Light Co.  

Science.gov (United States)

The report gives results of a survey of the flue gas desulfurization (FGD) systems at Kansas Power and Light Co.'s Lawrence Power Station. The systems utilize boiler injection of pulverized limestone, followed by tail-end wet scrubbing: unit 4, with a net...

1975-01-01

144

Survey of Flue Gas Desulfurization Systems Hawthorn Station, Kansas City Power and Light Co.  

Science.gov (United States)

The report gives results of a survey of the flue gas desulfurization (FGD) systems at Kansas City Power and Light Co.'s Hawthorn Power Station. The FGD systems on Hawthorn boilers 3 and 4 were designed to operate by injection of dry limestone in the boile...

1975-01-01

145

Supported soft material compensators for combined gas and steam turbine power stations. Gestuetzte Weichstoff-Kompensatoren fuer Gas-Dampfturbinen-Kombi-Block-Kraftwerke  

Energy Technology Data Exchange (ETDEWEB)

In combined cycle turbine power stations, soft material compensators are used which, if the full pressure fails, also withstand a small external pressure. Innovative forms of construction which guarantee useful life, are presented in relation to the design. Damaging effects, which limit the life of these special soft material compensators, are discussed. (orig.)

1994-09-01

146

Round Cell batteries in Class 1E applications  

International Nuclear Information System (INIS)

The AT and T Round Cell has recently become a viable alternative to the conventional, rectangular, lead acid storage batteries in Class 1E applications at US nuclear generating stations. This paper discusses the qualification of the Round Cell for nuclear generating stations, its principal design attributes, the types of Class 1E applications most suited for the Round Cell, and industry experience related to its installation and operation.

1996-04-09

147

Practice of radiation source control at Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

Daya Bay Nuclear Power Station has made a series of tries and efforts on radiation source control and benefited from them since it was put into commercial operation. Some of them were introduced from experience feedbacks of foreign nuclear power industry and others came from our own good practices

2004-05-01

148

Improved control of fuel crushing in coal-fired power stations  

Energy Technology Data Exchange (ETDEWEB)

With the frequent load changes to which a hard coal power station is subjected in the middle and peak load range, great demands are linked with the transient behaviour of the steam generator. Due to the serial connection of the crusher and boiler, the strongly delaying transient behaviour of the crusher compounds entirely with the transient behaviour of the steam generator. Therefore, a suggestion is to be made here as to the improvement of the dynamics of the crusher.

1988-01-01

149

Guangdong Daya Bay nuclear power station project  

International Nuclear Information System (INIS)

Daya Bay Nuclear Power Station is the largest joint-venture project which is also the largest commercial nuclear power plant currently under construction in China mainland. Organized and executed strictly in accordance with international standards, the Daya Bay project is seen as the first step taken by China in the development programme of large-capacity commercial nuclear power units.

1994-04-01

150

Far East combined-cycle update  

Energy Technology Data Exchange (ETDEWEB)

Korea Electric Power Corporation (Kepco) of South Korea has awarded Asea Brown Boveri Switzerland, a member of the ABB Group, a contract to supply the main equipment for two gas-fired combined-cycle power stations. News of the contract followed an announcement last year that Kepco will build a series of gas-fired power stations in the early 1990s to supply electricity to new housing and commercial areas being built in the Seoul-Incheon connurbation. (author).

1991-03-01

151

Environmental #gamma# dose rate monitoring system around Guangdong Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

This article introduces the composition, monitoring methods and working principles of environmental #gamma# dose rate continuous monitoring system at Guangdong Daya Bay Nuclear Power Station. The #gamma# dose rate monitoring status after modification of measurement conditions is introduced too.

152

Daya Bay Nuclear Power Station outdoors electrical equipment pollution status analysis and improving  

International Nuclear Information System (INIS)

According to the practice operation experience of the outdoors electrical equipment in Guangdong Daya Bay Nuclear Power Station, following to the engineering technical standard applied in China, by analysis and assessment of pollution classes, it is considered that the class four is reasonable. And indicated the voltage distance should be more than 3.5 cm/kV. Some improvements had been executed and effects are good. And further suggest some improving comments

2002-06-01

153

Cause analysis of cracks in circulating water culvert of Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

In view of the widespread cracks discovered in the reinforced-concrete circulating water culvert of Daya Bay Nuclear Power Station, cause analysis for the cracks is made in terms of construction and design. It is concluded that the cracks mainly resulted from shrinkage and temperature. Corresponding countermeasures are put forward thereafter for reference of similar projects

2000-06-01

154

Calculation of fission product behaviour in a station blackout accident of Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

The early accident Sequence of the Station Blackout accident is simulated for Daya Bay Nuclear Power Plant, using MELCOR code. The radioactivity of main fission products was derived after calculating the source term in containment. The data will be used for Daya Bay NPP PSA analysis

2002-12-01

155

Assessment of internal contamination due to gamma emitters at nuclear power stations of Tarapur  

International Nuclear Information System (INIS)

Personal monitoring and dose assessment of all radiation workers is an essential regulatory requirement as per radiation safety procedures of AERB and operating stations. The occupational workers of TAPS 1 and 2 and TAPS 3 and 4 are monitored for internal contamination due to high energy gamma emitters by whole body counting

2010-02-03

156

Imaging of reflection seismic and radar wavefields: Monitoring of steam-heated oil reservoirs and characterization of nuclear waste repositories  

Energy Technology Data Exchange (ETDEWEB)

A new three-dimensional (3D) acoustic modelling method was developed using a first-order hyperbolic wave system which was solved with explicit finite dfferences. The numerical solution of the 3D wave system provides a useful method for simulating evolution of a pressure field corresponding to compressional type waves. Existing two-dimensional (2D) elastic modelling algorithms were modified and fine-tuned for computationally efficient and realistic wave propagation simulations in complex structures. An original formulation of the 3D reverse time migration method was developed which is very accurate, does not suffer from unwanted evenescent energy, can image dips beyond 90{degree}, and does not generate multiple energy. Two case studies were performed that involved steam stimulation projects in the Cold Lake deposit. Simulations were performed during different phases of the steam stimulation process to examine the relation between reservoir properties and conditions with seismic ...

1994-12-31

157

Groundwater penetrating radar and high resolution seismic for locating shallow faults in unconsolidated sediments  

Energy Technology Data Exchange (ETDEWEB)

Faults in shallow, unconsolidated sediments, particularly in coastal plain settings, are very difficult to discern during subsurface exploration yet have critical impact to groundwater flow, contaminant transport and geotechnical evaluations. This paper presents a case study using cross-over geophysical technologies in an area where shallow faulting is probable and known contamination exists. A comparison is made between Wenner and dipole-dipole resistivity data, ground penetrating radar, and high resolution seismic data. Data from these methods were verified with a cone penetrometer investigation for subsurface lithology and compared to existing monitoring well data. Interpretations from these techniques are compared with actual and theoretical shallow faulting found in the literature. The results of this study suggests that (1) the CPT study, combined with the monitoring well data may suggest that discontinuities in correlatable zones may indicate that faulting ...

1993-12-31

158

Ground penetrating radar and direct current resistivity evaluation of the desiccation test cap, Savannah River Site  

Energy Technology Data Exchange (ETDEWEB)

The Savannah River Site (SRS) has a variety of waste units that may be temporarily or permanently stabilized by closure using an impermeable cover to prevent groundwater infiltration. The placement of an engineered kaolin clay layer over a waste unit is an accepted and economical technique for providing an impermeable cover but the long term stability and integrity of the clay in non-arid conditions is unknown. A simulated kaolin cap has been constructed at the SRA adjacent to the Burial Ground Complex. The cap is designed to evaluate the effects of desiccation on clay integrity, therefore half of the cap is covered with native soil to prevent drying, while the remainder of the cap is exposed. Measurements of the continuing impermeability of a clay cap are difficult because intrusive techniques may locally compromise the structure. Point measurements made to evaluate clay integrity, such as those from grid sampling or coring and made through a soil cover, may miss cracks, joints or ...

1996-04-01

159

Evaluation of methods to measure surface level in waste storage tanks: Second test sequence  

Energy Technology Data Exchange (ETDEWEB)

This report describes the results of a program conducted at the Pacific Northwest Laboratory (PNL) and Westinghouse Hanford Company (WHC) to identify alternative methods to measure the surface level in the waste tanks. This program examined commercially available devices for measuring the distance to a target. This is a continuation of a program started in FY93. In the first test sequence, tests were performed.on five devices to determine their applicability to measure the surface level in the waste tanks. The devices were the Enraf-Nonius{trademark} Model 872 Radar Gauge, the Enraf-Nonius{trademark} Model 854 Advanced Technology Gauge (ATG), the Stanley Tool Laser Measuring Device, the Robertshaw Inven-Tel{reg_sign} Precision Level Gauge, and the Micro Switch Model 942 Acoustic Sensor. In addition, discussions were held with several manufacturer representatives regarding other potential devices. The results of these tests were documented in a previous report. Two ...

1993-09-01

160

Modeling of a horizontal steam generator for the submerged nuclear power station concept  

Energy Technology Data Exchange (ETDEWEB)

A submerged nuclear power station has been proposed as an alternative power station with a relatively low environmental impact for use by both industrialized and developing countries. The station would be placed 10 m above the seabed at a depth of 30--100 m and a distance of 10--30 km from shore. The submerged nuclear power station would be manufactured and refueled in a central facility, thus gaining the economies of factoryfabrication and the flexibility of short-lead-time deployment. To minimize the size of the submerged hull, horizontal steam generators are proposed for the primary-to-secondary heat transfer, instead of the more traditional vertical steam generators. The horizontal steam generators for SNPS would be similar in design to the horizontal steam generators used in the N-Reactors except the tube orientation is horizontal (the tube's inlet and outlet connection points on the ...

1993-01-01

161

Modeling of a horizontal steam generator for the submerged nuclear power station concept  

Energy Technology Data Exchange (ETDEWEB)

A submerged nuclear power station has been proposed as an alternative power station with a relatively low environmental impact for use by both industrialized and developing countries. The station would be placed 10 m above the seabed at a depth of 30--100 m and a distance of 10--30 km from shore. The submerged nuclear power station would be manufactured and refueled in a central facility, thus gaining the economies of factoryfabrication and the flexibility of short-lead-time deployment. To minimize the size of the submerged hull, horizontal steam generators are proposed for the primary-to-secondary heat transfer, instead of the more traditional vertical steam generators. The horizontal steam generators for SNPS would be similar in design to the horizontal steam generators used in the N-Reactors except the tube orientation is horizontal (the tube`s inlet and outlet connection points on the tubesheet are ...

1993-05-01

162

Modeling of a horizontal steam generator for the submerged nuclear power station concept  

International Nuclear Information System (INIS)

A submerged nuclear power station has been proposed as an alternative power station with a relatively low environmental impact for use by both industrialized and developing countries. The station would be placed 10 m above the seabed at a depth of 30--100 m and a distance of 10--30 km from shore. The submerged nuclear power station would be manufactured and refueled in a central facility, thus gaining the economies of factoryfabrication and the flexibility of short-lead-time deployment. To minimize the size of the submerged hull, horizontal steam generators are proposed for the primary-to-secondary heat transfer, instead of the more traditional vertical steam generators. The horizontal steam generators for SNPS would be similar in design to the horizontal steam generators used in the N-Reactors except the tube orientation is horizontal (the tube's inlet and outlet connection points on the tubesheet are ...

1993-07-06

163

Aquatic macroinvertebrates and water quality in Sandia Canyon  

International Nuclear Information System (INIS)

In 1990, field studies of water quality and stream macroinvertebrate communities were initiated in Sandia Canyon at Los Alamos National Laboratory. The studies were designed to establish baseline data and to determine the effects of routine discharges of industrial and sanitary waste. Water quality measurements were taken and aquatic macroinvertebrates sampled at three permanent stations within the canyon. Two of the three sample stations are located where the stream regularly receives industrial and sanitary waste effluents. These stations exhibited a low diversity of macroinvertebrates and slightly degraded water quality. The last sample station, located approximately 0.4 km (0.25 mi) downstream from the nearest wastewater outfall, appears to be in a zone of recovery where water quality parameters more closely resemble those found in natural streams in the Los Alamos area. A large increase in ...

2005-09-01

164

Comprehensive report to Congress Clean Coal Technology Program: Warren Station EFCC Demonstration Project  

Energy Technology Data Exchange (ETDEWEB)

One of the five projects selected for funding within the Clean Coal Technology Program is a project proposed by the Pennsylvania Electric Company (Penelec) of Johnstown, Pennsylvania. Penelec proposes to enter into a cooperative agreement with DOE to design, construct and operate a 600 ton-per-day, 66-megawatt (MWe), coal-fueled, externally-fired combined cycle (EFCC) electric power generation facility. The EFCC is an emerging technology with promise for operating highefficiency combined gas- and steam-turbine cycles on coal. The central feature of EFCC is its coupling of the gas turbine to an external, atmospheric-pressure, coal combustor via a hightemperature ceramic heat exchanger (CerHx{reg_sign}) developed by Hague International. The EFCC technology is attractive because, unlike competing combined cycles such as Integrated Gasification (IGCC) and Pressurized Fluidized Bed Combustion (PFBC), it eliminates the need for a costly gas cleanup system to protect the gas turbine ...

1994-06-01

165

Utilization of geothermal energy in the USSR  

International Nuclear Information System (INIS)

This paper reports that at present geothermal energy is utilized in the USSR mostly for district heating, and for industrial and agricultural purposes. The populations of 7 towns have district heating that is supplied by thermal waters. The population supplied totals about 125,000 people. The total area of greenhouses is 850,000 m"2. Electric energy generated at geothermal power stations still remains negligible with the installed capacity of the single Pauzhetka station (Kamchatka) being 11 MW. another station at Mutnovka is currently under construction and is expected to be producing 50 MW by 1992 and 200 MW by 1998. The proven geothermal resources in the USSR provide hope for a significant increase in the utilization of the earth's deep heat in the near future.

1990-08-20

166

U.S. Department of Energy, Nevada Operations Office, Environmental Monitoring Program: Summary data report - first and second calendar quarters 1994  

International Nuclear Information System (INIS)

During the first and second quarters of 1994 air samples were collected and analyzed from 54 air particulate/halogen sampling stations, 10 noble gas sampling stations and 19 tritiated water vapor sampling stations. Surface water samples were collected and analyzed from 12 open water supply reservoirs, 8 natural springs, 2 wastewater containment ponds and 9 sewage lagoons. Groundwater samples were obtained brom 10 potable and 1 non-potable supply wells, and 8 drinking water consumption points. Ambient radiation levels were measured at 193 locations.

1991-10-31

167

Thermal impact analysis of discharge of circulating cooling water at Daya Bay Nuclear Power Station (GNPS) and Ling'ao Nuclear Power Station (LNPS)  

International Nuclear Information System (INIS)

The circulating cooling water flowrate of GNPS and LNPS is totally about 190 m"3/s. Both stations are located on the western coast of semi-closed Daya Bay. A lot of studies concerning thermal impact of GNPS and LNPS have been carried out since 1987, including mathematical model, physical model, on-site survey and satellite remote sensing, etc. This paper describes the hydrological features of Daya Bay and discharge characteristics of circulating water of GNPS and LNPS, estimates the actual thermal impact of GNPS and LNPS, and indicates that it is advantageous for the dilution of circulating water while the two discharge channels of GNPS and LNPS are combined together towards east

2004-05-01

168

The influence of contrasting suspended particulate matter transport regimes on the bias and precision of flux estimates  

British Library Electronic Table of Contents (United Kingdom)

A large database (507 station-years) of daily suspended particulate matter (SPM) concentration and discharge data from 36 stations on river basins ranging from 600?km2 to 600,000?km2 in size (USA and Europe) was collected to assess the effects of SPM transport regime on bias and imprecision of flux estimates when using infrequent surveys and the discharge-weighted mean concentration method. By extracting individual SPM concentrations and corresponding discharge values from the database, sampling frequencies from 12 to 200 per year were simulated using Monte Carlo techniques. The resulting estimates of yearly SPM fluxes were compared to reference fluxes derived from the complete database. For each station and given frequency, bias was measured by the median of relative errors between estima...

2006-01-01

169

Regulatory aspects about the licensing of the improved technical specifications for the CNLV  

International Nuclear Information System (INIS)

The Operation Technical Specifications is a document that is attached to the Operation License of a nuclear power station and its are applicable since the first load of fuel begins in the reactor core. This document is normative and with its application it is assured the safe operation of the nuclear power station. For the case of the Laguna Verde Nucleo electric Central this is documented in the Condition No. 5 of the License of Operation. Any modification to the ETOs is subject to the evaluation by part of the regulator organism. This work describes the regulator frame and the evaluation process of the Improved Technical Specifications on the part of the regulator organism. It is also indicated the implementation process of the improved ETOs and the main characteristics and benefits that are obtained of these processes to maintain the safety of the nuclear power stations. (Author)

2007-07-01

170

Quality engineering programme in the design process. A major utility 's experience  

International Nuclear Information System (INIS)

The paper describes the latest approach to quality engineering in the design process as applied by Ontario Hydro throughout the various phases of the project life cycle for Ontario Hydro generating stations and related facilities. Ontario Hydro has long recognized that the high quality and performance required in nuclear generating stations start in the design process and can best be achieved through an adequate and proper quality engineering programme in design. The current approach has evolved over a period of six years and represents a meaningful and effective series of requirements, functions and activities, which are used to ensure safety, reliability, economy and environmental acceptability of nuclear generating stations. (author).

171

Photochemical assessment monitoring: Overview and current status  

Energy Technology Data Exchange (ETDEWEB)

The Clean Air Act Amendments of 1990, established requirements for the Environmental Protection Agency (EPA) to develop rules for the establishment of enhanced ozone monitoring networks or Photochemical Assessment Monitoring Stations (PAMS) in ozone nonattainment areas designated as serious, severe, and extreme. The subsequent rules require these stations to collect ambient air measurements for a target list of volatile organic compounds including several carbonyls, oxides of nitrogen, ozone, and meteorological measurements, both surface and upper air. Twenty-two areas in the US are obligated to install and operate PAMS stations to aid in the identification, development, and implementation of effective ozone control strategies. This paper will examine the specific requirements of the PAMS rules and will provide information regarding the current status of the networks and overall implementation issues.

1994-12-31

172

Behaviour of the steam generators in the Belgian nuclear power plants  

International Nuclear Information System (INIS)

After a brief review of the degradations occurring on tubes of Inconel 600 in steam generators of PWR power stations emphasis is put on the conditioning of the secondary water and more particularly on the condensate treatment in the units of Doel which work on heavily polluted brackish water. The important role of non-destructive testing and eddy-current testing is also pointed out, method developed by Laborelec. The operational experience shows that Belgian stations are nearly not concerned by the degradations mostly found in power stations in other countries which shows the efficiency of the conditioning of the secondary water. On the other hand, other problems have occurred, resulting from: damage caused by foreign objects; fouling of tube before commissioning, cracking of bends and at the limit of the dudgeoning and leaking plugs. (AF).

1986-04-15

173

Application of nuclear energy for power generation at TAPS 3 and 4  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station, Unit 3 and 4 is located on the West Coast of the Arabian Sea near the existing Tarapur Atomic Power Station Unit 1 and 2. The nearest railway station is Boisar at a distance of 12 km from the site, which is on the main Western Railway Mumbai-Delhi route. The site is well connected by road and is about 30 Km from Mumbai-Ahmedabad National Highway-NH-8. The paper describes the land acquisition and rehabilitisation of the affected families, importance of project in the western grid, how it works, working principles of PHWR, principle of operation, major components/equipment, important systems, safety features, and waste management

2010-10-01

174

The use of neutron activation analysis for the study of environmental risks associated with the fly ash from burning Polish coals  

International Nuclear Information System (INIS)

This report presents leaching experiments with irradiated fly ash from the Kozienice Power Station and, as a reference, with a Czechoslovakian fly ash sample. 7 refs, 11 figs, 3 tabs.

1991-09-10

175

Steam turbines for cogeneration plants; Dampfturbinen fuer die Kraft-Waerme-Kopplung  

Energy Technology Data Exchange (ETDEWEB)

The demand for cogeneration plants is growing worldwide. For the combination of electricity generation and heat extraction in power stations facilitates an excellent fuel exploitation and makes the operator of the plant independent from external energy suppliers. (orig.)

2006-07-01

176

Stations Maidanak2  

Science.gov (United States)

Identification of the Ranging System Reference Point (SRP) ... Daylight Filter Type : (SPECTRAL FILTER/FABRY-PEROT/etc) Dayl. Filt. ... INT/etc) Edit Criterion 1st Chain : (ITERATIVE n.n SIGMA/MANUAL/NONE/etc) Edit Criterion 2nd Chain ...

177

Stations Maidanak1  

Science.gov (United States)

Identification of the Ranging System Reference Point (SRP) ... Daylight Filter Type : (SPECTRAL FILTER/FABRY-PEROT/etc) Dayl. Filt. ... INT/etc) Edit Criterion 1st Chain : (ITERATIVE n.n SIGMA/MANUAL/NONE/etc) Edit Criterion 2nd Chain ...

178

Solar Cogeneration Facility: Cimarron River Station, Central Telephone and Utilities-Western Power. Executive summary  

Energy Technology Data Exchange (ETDEWEB)

A brief overview of the conceptual design of a solar central receiver system integrated with an existing cogeneration facility is provided. A synopsis of the performance and economic evaluation, and an assessment of the concept from the site owner's perspective are given.

1981-08-07

179

Sodium sulphur starts to deliver. [High power density battery  

Energy Technology Data Exchange (ETDEWEB)

The development of a high power density sodium sulphur battery with a five-year maintenance-free life is described. These batteries are likely to be used in industrial trucks, milk floats, electric cars, storing power station output and power for satellites. (U.K.).

1985-10-03

180

Priroda module docks with Mir station today - Johnson Space Center ...  

Science.gov (United States)

Apr 26, 1996 ... StainlesssteelJenn-Air cooktop w/4 burners, $20. Sam,332-3168. Sale:Condo, Friendswood,3-2-2A,1411sq It,. 409-925-4862. ...

181

Prematurity as a public health problem: US policy from the 1920s to the 1960s.  

UK PubMed Central (United Kingdom)

During the 1920s and 1930s, a number of physicians created model premature infant stations in select hospitals, arguing that medicine could successfully treat premature infants, most of whom could be...Full Text Available

1996-06-01

182

Potamonautes paecilei  

Science.gov (United States)

... Binya, Banyala; Binya, Equateur; Flandria; Isangila; Kosa-Kosa. Matadi, Mporo River; Stanleypool Station 35, Nsele River; Maniema, ... River; Riv. Talya, Bilboma, kamituga Talya river 2. Matadi, Luashi. I...

183

Physical Basis for the Lg/P Discriminant: General Properties and Preliminary Modeling.  

Science.gov (United States)

A critical problem for reliable implementation of regional discrimination is incomplete understanding of how regional seismic signals depend on physical characteristics of the source and propagation path to the recording station. This research is directed...

1997-01-01

184

Outboard Waterjet Propulsion Development.  

Science.gov (United States)

The project is currently on schedule. The design review meeting was held on 08/26/97 at the Coastal Systems Station in Panama City, Florida. The mechanical arrangement, performance analysis and design features were presented at the review meeting. A numbe...

1997-01-01

185

Operation of Grand Gulf Nuclear Station, Units 1 and 2, Dockets Nos. 50-416 and 50-417: Mississippi Power and Light Company, Middle South Energy, Inc. , South Mississippi Electric Power Association. Final environmental statement  

Energy Technology Data Exchange (ETDEWEB)

The information in this Final Environmental Statement is the second assessment of the environmental impacts associated with the construction and operation of the Grand Gulf Nuclear Station, Units 1 and 2, located on the Mississippi River in Claiborne County, Mississippi. The Draft Environmental Statement was issued in May 1981. The first assessment was the Final Environmental Statement related to construction, which was issued in August 1973 prior to issuance of the Grand Gulf Nuclear Station construction permits. In September 1981 Grand Gulf Unit 1 was 92% complete and Unit 2 was 22% complete. Fuel loading for Unit 1 is scheduled for December 1981. The present assessment is the result of the NRC staff review of the activities associated with the proposed operation of the Station, and includes the staff responses to comments on the Draft Environmental Statement.

1981-09-01

186

Onboard Systems Record Unique Videos of Space Missions - NASA  

Science.gov (United States)

May 1, 2011 ... Onboard Systems Record Unique Videos of Space Missions ... Corporation, An artist's rendering of LCROSS launching toward the Moon .... Station (ISS) as part of the Commercial Orbital Transportation Services program. ...

187

Oettinger pushes for stress tests of Europe'  

Wastenet

... Austrian Environment Minister Nikolaus Berlakovich called for such stress tests on Sunday (13 March) to make sure that nuclear power stations were quake-proof following Japan's massive earthquake and tsunami. Austria, a mountainous country rich in geothermal energy, has no NPPs and no plans to develop ...

188

Northern Indiana Public Service Company Clean Air Act Settlement...  

Science.gov (United States)

retirement of the Dean H. Mitchell Station Installation of three new flue gas desulfurization systems (FGD) at Schahfer 14, Schahfer 15, and Michigan City 12 Upgrades to...

2011-01-19

189

NASA reopens space station job notices - Johnson Space Center  

Science.gov (United States)

Oct 11, 1993 ... Lease: Meadowgreen,3-2.5-2, 2 storyon cuI- ..... also will have the Lunar Landing Training Vehicle elevated over the center of the ...

190

N A S A T'ECHNICAL, - NASA Technical Reports Server  

Science.gov (United States)

Four temperature sensors were provided instead of the previous two sensors. 4. ... Incoming signals from either one or two ground stations at a frequency of .... The propulsion subsystem consists of a single solid-propellant rocket motor. ...

191

Methodology for designing air-quality-monitoring networks. 1. Theoretical aspects  

Energy Technology Data Exchange (ETDEWEB)

An objective methodology is presented for determining the number and disposition of ambient air-quality stations in a monitoring network for the primary purpose of compliance with air-quality standards. The methodology utilizes a data base with real or simulated data from an air quality dispersion model for application with a two-step process for ascertaining the optimal monitoring network. In the first step, the air-quality patterns in the data base are collapsed into a single composite pattern through a figure-of-merit (FOM) concept. The most-desirable locations are ranked and identified using the resultant FOM fields. In the second step the network configuration is determined on the basis of the concept of spheres of influence (SOI) developed from cutoff values of spatial-correlation coefficients between potential monitoring sites and adjacent locations. The minimum number of required stations is then determined by deletion of lower-ranked ...

1986-01-01

192

Measurement and analysis of temperature, strain and stress of foundation mat concrete in nuclear and thermal power stations  

International Nuclear Information System (INIS)

The problems of the thermal stress in concrete structures are roughly divided into the initial stress due to setting heat and the stress due to external temperature after hardening. The initial stress exists in every concrete structure, and it is usually neglected in beams and columns, but it must be taken into account in case of the foundation mat structures in nuclear power stations, for example. In this paper, (1) the results of measurement of temperature, strain and stress in each lift at the time of and after placing concrete in the foundation mat of a nuclear power station and the comparison of them with the results of analysis, (2) the results of measurement of the temperature and stress in a foundation mat, which was carried out to rationalize the design method for the raft type foundation mats in thermal power stations, and (3) the results of examination on the analysis model, external force conditions and boundary ...

193

Mach 4 Performance of Hypersonic Inlet with Rectangular-to ...  

Science.gov (United States)

station in flowmeter used for mass flow calculation. Introduction. THE design .... length (as a result of a less conservative boundary-layer separation criterion), 2) slight ..... ical Flow, AGARD Conference Proceedings, No. 30, 1968. 5Kantrowitz ...

194

International Space Station Overview - NASA  

Science.gov (United States)

(accumulates & stores brine for disposal). Separator. (separates water from purge gases). ? Purge pump periodically vent ... Reactor Health. Sensor. ( verifies reactor is operating w/n limits) ... Waste and Hygiene Compartment ...

195

How to charge electric-powered automobiles; Volle Ladung, aber wie?  

Energy Technology Data Exchange (ETDEWEB)

Electric cars can be recharged via charging stations, battery exchange, or induction cable lanes in asphalted roads. The users' wishes remain unexplored, so a number of technologies are competing in this sector.

2011-01-15

196

Harnessing the geothermal resources of sedimentary basins for electricity production  

Science.gov (United States)

Use of geothermal resources for generating electricity is briefly analyzed. Results obtained from optimization of the thermodynamic cycle implemented in the secondary coolant circuit of a binary geothermal power station and the parameters of its primary heat carrier circuit are presented.

2011-02-01

197

Expedition crew rotation highlights upcoming shuttle mission  

Science.gov (United States)

Feb 23, 2001 ... Florida, as an F-16 weapons separation engineer with .... new era of space-based research aboard the International Space. Station. ..... the Web at: http://www. aiaa.org/calen- dar/index.hfm?cal=1&cfp=1 ...

198

Electromagnetic fields, pacemakers and defibrillators; Champs electromagnetiques, cardiostimulateurs et defibrillateurs  

Energy Technology Data Exchange (ETDEWEB)

Presentation of electromagnetic sources constituted by various radio transmitters contributing to different radio communication services in the environment. Results of a measures campaign to assess the electromagnetic field in the close neighbourhood of various stations. Analysis by frequency domains. (author)

2004-07-01

199

Electricity generation: options for reduction in carbon emissions  

Energy Technology Data Exchange (ETDEWEB)

Historically, the bulk production of electricity has been achieved by burning fossil fuels, with unavoidable gaseous emissions, including large quantities of carbon dioxide: an average-sized modern coal-burning power station is responsible for more than 10 Mt of CO{sub 2} each year. This paper details typical emissions from present-day power stations and discusses the options for their reduction. Acknowledging that the cuts achieved in the past decade in the UK CO{sub 2} emissions have been achieved largely by fuel switching, the remaining possibilities offered by this method are discussed. Switching to less-polluting fossil fuels will achieve some measure of reduction, but the basic problem of CO{sub 2} emissions continues. Of the alternatives to fossil fuels, only nuclear power represents a zero-carbon large-scale energy source. Unfortunately, public concerns over safety and radioactive waste have still to be assuaged. Other approaches ...

2002-07-01

200

Cordoba and Wolsung Projects: A Progress Report.  

Science.gov (United States)

The Cordoba and Wolsung projects mark the entry into the international sales arena of the standardized Canadian 600 MWe CANDU-PHW reactor design. The Cordoba station experienced a setback in the early stages when severe inflation in Argentina led to a ren...

1977-01-01

201

Consideration of field experience in developing new projects of steam generators for nuclear power stations equipped with VVER reactors  

British Library Electronic Table of Contents (United Kingdom)

The main problems encountered during the operation of horizontal steam generators are considered. Design features of the new PGV-1000MK and PGV-1500 steam generators are analyzed.

2006-01-01

202

Conawapa to Winnipeg Power Transmission Complex. Southern Receiver System: Environmental impact assessment status report  

International Nuclear Information System (INIS)

Development of the Conawapa-Winnipeg power transmission complex in Manitoba includes five interrelated transmission and conversion facilities. Environmental and socio-economic assessment work done to date on one component of this system (the upgrading of the Southern Receiver System) is described. This system is composed of a network of high voltage transmission lines and station facilities serving power demand in Winnipeg and southern Manitoba. The upgrading involves three main elements: energizing a second 230 kV ac circuit on an existing tower line running from the proposed Riel Station site to the existing St. Vital Station; constructing a new double-circuit 230 kV tower line on the same existing right-of-way between St. Vital and the Riel site area; and installing an additional transformer and other necessary equipment at St. Vital and other stations affected by the upgrade. The environmental ...

1992-01-01

203

Application of a power system stabilizer in the nuclear power plant Borssele  

Energy Technology Data Exchange (ETDEWEB)

After that power fluctuations had occurred at Borssele nuclear power station it was decided to install a power system stabilizer. This stabilizer shall reduce the unwanted power fluctuations. The preliminary research and the results of measurements carried out during commissioning are described. (J.C.R.)

1985-03-01

204

An example of use of SAT for NPP training OJT model  

International Nuclear Information System (INIS)

The non-licensed operator on the job training model presently considered for development and implementation at C.N. Almaraz (CNA) has the primary objective of imparting practical knowledge and skills to the trainee on a per system basis and specific to the job position. This model is somewhat different in scope from the OJT process used in U.S. stations because the learning process is not done on a task per task basis, but rather on the concept of learning collectively all the knowledge and skills required by the specific-system job. This model arose primarily from two thoughts. First, the knowledge and skills have been obtained from a detailed job and task analysis process which will result in the learning of many required knowledge and skills divided by three categories: components, systems and academics. Secondly, the OJT most commonly used in the U.S. requires that the respective station department administers and implements the OJT ...

1994-03-21

205

rf system for the Los Alamos free-electron laser (FEL)  

Energy Technology Data Exchange (ETDEWEB)

The FEL electron linac consists of three buncher cavities: two accelerator cavities and a deflection cavity, each with its own phase-coherent rf source. All sources will be pulsed for 100 ..mu..s at a 1-pps rate. The phase and amplitude stability requirements are +-1/2/sup 0/, and +-1/2%. There are two subharmonic bunchers, each requiring 5 kW at 108.33 MHz. All remaining cavities operate at 1300 MHz. The fundamental buncher requires 5 kW, whereas each of the accelerating cavities requires at least 3 MW. The deflection cavity requires up to 100 kW, which is coupled from one of the accelerator cavity rf sources. Prominent features of the rf system are the phase and amplitude control circuits and the multimegawatt klystron amplifiers. Three L3707 klystrons were obtained from the AMRAD radar site at White Sands, which was decommissioned in the early 1970s. The tubes originally were designed to produce 10-MW, 10-..mu..s pulses. Each tube has delivered over 3.6-MW, ...

1983-01-01

206

rf system for the Los Alamos free-electron laser (FEL)  

International Nuclear Information System (INIS)

The FEL electron linac consists of three buncher cavities: two accelerator cavities and a deflection cavity, each with its own phase-coherent rf source. All sources will be pulsed for 100 #mu#s at a 1-pps rate. The phase and amplitude stability requirements are +-1/2_0, and +-1/2%. There are two subharmonic bunchers, each requiring 5 kW at 108.33 MHz. All remaining cavities operate at 1300 MHz. The fundamental buncher requires 5 kW, whereas each of the accelerating cavities requires at least 3 MW. The deflection cavity requires up to 100 kW, which is coupled from one of the accelerator cavity rf sources. Prominent features of the rf system are the phase and amplitude control circuits and the multimegawatt klystron amplifiers. Three L3707 klystrons were obtained from the AMRAD radar site at White Sands, which was decommissioned in the early 1970s. The tubes originally were designed to produce 10-MW, 10-#mu#s pulses. Each tube has delivered over 3.6-MW, 100-#mu#s ...

1983-03-21

207

The RF system for the Los Alamos free electron laser (FEL)  

International Nuclear Information System (INIS)

The FEL electron linac consists of three buncher cavities: two accelerator cavities and a deflection cavity, each with its own phase-coherent rf source. All sources will be pulsed for 100 #mu#s at a 1-pps rate. The phase and amplitude stability requirements are + or - 1/2"0, and + or - 1/2%. There are two subharmonic bunchers, each requiring 5 kW at 108.33 MHz. All remaining cavities operate at 1300 MHz. The fundamental buncher requires 5 kW, whereas each of the accelerating cavities requires at least 3 MW. The deflection cavity requires up to 100 kW, which is coupled from one of the accelerator cavity rf sources. Prominent features of the rf system are the phase and amplitude control circuits and the multimegawatt klystron amplifiers. Three L3707 klystrons were obtained from the AMRAD radar site at White Sands, which was decommissioned in the early 1970s. The tubes originally were designed to produce 10-MW, 10-#mu#s pulses. Each tube has delivered over 3.6-MW, ...

208

One-class classifier networks for target recognition applications  

Energy Technology Data Exchange (ETDEWEB)

Target recognition requires the ability to distinguish targets from non-targets, a capability called one-class generalization. Many neural network pattern classifiers fail as one-class classifiers because they use open decision boundaries. To function as one-class classifier, a neural network must have three types of generalization: within-class, between-class, and out-of-class. We discuss these three types of generalization and identify neural network architectures that meet these requirements. We have applied our one-class classifier ideas to the problem of automatic target recognition in synthetic aperture radar. We have compared three neural network algorithms: Carpenter and Grossberg`s algorithmic version of the Adaptive Resonance Theory (ART-2A), Kohonen`s Learning Vector Quantization (LVQ), and Reilly and Cooper`s Restricted Coulomb Energy network (RCE). The ART 2-A neural network gives the best results, with 100% within-class, between-class, and ...

1993-01-01

209

Electromagnetic radiation unmasked  

International Nuclear Information System (INIS)

This article describes the nature of the electromagnetic waves, what they are and how do they affect us. Current concern is focused on exposure to low level power-frequency magnetic fields like microwave radiation from mobile phones and leaking microwave ovens; high power radiation from defence and airport radars; fields close to high voltage transmission lines; radio frequency fields from industrial welders and heaters and DC magnetic fields in aluminium smelters. These fields with frequency less than 300 GHz do not carry sufficient energy to break chemical bonds and it is assumed that they cannot damage cell DNA. The amount of radiation absorbed by a human exposed to far field electromagnetic radiation (EMR) depends on the orientation and size of the person. In the 30-300 MHz range it is possible to excite resonance in the whole or partial body such as the head. It is emphasised that since there are some evidence that electromagnetic fields do harm, a policy of ...

1996-01-01

210

A comparison of two operational wave assimilation methods  

CERN Document Server

A comparison is carried out between two operational wave forecasting/assimilation models for the North Sea, with the emphasis on the assimilation schemes. One model is the WAM model, in combination with an optimal interpolation method (OIP). The other model, DASWAM, consists of the third generation wave model PHIDIAS in combination with an approximate implementation of the adjoint method. In an experiment over the period February 19 - March 30, 1993, the models are driven by the same wind field (HIRLAM analysis winds), and the same observation data set is assimilated. This set consists of a) spectra from three pitch-and-roll buoys and b) Synthetic Aperture Radar (SAR) spectra from the ERS-1 satellite. Three analysis/forecast runs are performed: one without assimilation, one with assimilation of buoy measurements only, and one with all data assimilated. For validation, observations from four buoys, altimeter data from ERS-1 and Topex-Poseidon, and scatterometer data ...

1997-01-01

211

WATER SUPPLY ANALYSIS  

Energy Technology Data Exchange (ETDEWEB)

This analysis defines and evaluates the surface water supply system from the existing J-13 well to the North Portal. This system includes the pipe running from J-13 to a proposed Booster Pump Station at the intersection of H Road and the North Portal access road. Contained herein is an analysis of the proposed Booster Pump Station with a brief description of the system that could be installed to the South Portal and the optional shaft. The tanks that supply the water to the North Portal are sized, and the supply system to the North Portal facilities and up to Topopah Spring North Ramp is defined.

1996-02-06

212

Utilisation and disposal of residues (ash, gypsum and granulate) from BEWAG pulverised coal and fluidised bed fired power stations  

Energy Technology Data Exchange (ETDEWEB)

Describes the wastes produced and the waste disposal methods used at BEWAG power plants. Wastes covered include fly ash, fluidized bed ash, gypsum from flue gas desulfurization and evaporation residues. Disposal methods include using ashes and gypsum to make building materials. Despite many years of experience in the utilization and disposal of residues from coal-fired power stations BEWAG have not encountered any disposal problems. 5 tabs.

1993-01-01

213

The root cause analysis of 9DVN002ZV fan failure in Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

Extensive investigations and detailed analysis of the failure reason of 9DVN002ZV fan in Daya Bay Nuclear Power Station showed that the fan destroy was caused by the failure of non-drive end bear. The direct cause of this bearing' failure was its improper assembly caused by improper maintenance procedure, and the root cause was too small internal radial clearance after mounting. The factor affecting bearing internal radial clearance, the relationship between clearance and operating life time and fan failure process were discussed. (authors)

2005-09-01

214

Steam turbines  

International Nuclear Information System (INIS)

The author gives the historical development of steam-turbine construction in Europe since the turn of the century, and the technical further development of conventional turbines due to the increases in the steam parameters and per-unit outputs in the increases in the steam parameters and per-unit outputs in Europe and the USA. Marginal conditions for the development of turbines in nuclear power stations with light-water reactors are mentioned. The rise in the per-unit capacities of the turbosets constructed in Germany and the USA for nuclear power stations is discussed. Longitudinal sections through typical turbines are shown. The future development of turbines with high output is dealt with. (orig.).

215

Standard radiation monitoring at Sendai nuclear power station  

International Nuclear Information System (INIS)

Standard radiation monitoring has been conducted at Sendai nuclear power station for the purpose of estimation of 'source activity' during refueling outage and evaluation of countermeasures to reduce dose rate. Selected objects of the monitoring are radiation dose rate at maintenance area, radiation field at each equipment and piping, coolant chemistry and plant operation condition. Monitored data indicates that 'source activity' variation can be estimated to some extent using influential factors, and that evaluation of change of loose crud activity, which is presumed to be represented by the dose rate at letdown heat exchanger, is necessary to further explain change in radiation field at main work area. (author).

216

Solar power station. Sonnenkraftwerk  

Energy Technology Data Exchange (ETDEWEB)

The invention concerns a solar power station with a hollow solar heater, which has reflected radiation coming in, focussed by a mirror through the inlet opening. To match the differing solar radiation during the day, the inlet opening can be adjusted by changing its cross-section. This is done by at least two thick flat circular parts which can move relative to each other which are preferably movable relative to each other in pairs on a common rail and which are cooled by a coolant which is the working medium for absorbing solar energy.

1982-02-25

217

Results of the 2nd periodical inspection of the asphalt solidification facility and the incinerator in Unit 2 of the Sendai Nuclear Power Station  

International Nuclear Information System (INIS)

The 2nd periodical inspection was carried out on the asphalt solidification facility and the incinerator in Unit 2 of the Sendai Nuclear Power Station from November 5 to 28, 1985. Inspection was made in radiation control facility and disposal facility. By external appearance, disassembly, function and performance tests there were observed no abnormalities. The personnel exposure doses during the inspection were below the permissible level. In the inspection, improvement etc. works were not done. (Mori, K.).

1986-01-01

218

Results of regular inspection of No.2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc  

International Nuclear Information System (INIS)

The regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from January 7 to February 8, 1985. The summary of the results of this regular inspection is as follows. The facilities as the object of inspection were radiation control facilities and waste facilities. On these facilities as the object of inspection, the appearance, disassembling, functional, performance and other inspections were carried out, and as the results, abnormality was not found at all. The works related to this regular inspection were accomplished within the range of the allowable radiation dose based on the relevant laws. (Kako, I.).

1986-01-01

219

Replacement of bearing journals on heat transport pumps at the Wolsung nuclear generating station  

International Nuclear Information System (INIS)

The major details of the inspection and replacement of the bearing journals on each of the four heat transport pumps (HTPs) at Wolsung nuclear generating station in Korea are presented in this paper. Investigation following fracture of one of the journals in 1985 revealed that it was excessively hard. The journal material (ASTM A296 CA 40) is considered to be prone to stress corrosion fatigue if the hardness exceeds Rc 40. In 1986 May, during a planned outage, the HTPs were disassembled, the journals were inspected, found to be excessively hard, and all were replaced. At the same time, the pump to motor couplings were all refurbished to ensure proper alignment.

1987-11-22

220

Reducing the breakdowns and energy consumption in pressure regulating stations by rationalizing the heating of gas  

Energy Technology Data Exchange (ETDEWEB)

Sigma 1) examines ways to reduce the number of breakdowns of pressure-regulating stations and to minimize the energy consumed in warming the gas, 2) determines the optimal gas temperatures upstream from the pressure reduction, and 3) shows the dependence of energy consumption upon the water dewpoint. The method of calculating the optimal input temperature relies on Mollier's diagram. Tables and nomographs for natural gas and water dewpoint at 19/sup 0/F and 580 psi (-7/sup 0/C and 4 MPa) are useful in achieving the desired gas temperatures. Heating the regulators' control valves is important.

1982-04-01

221

Probabilistic safety assessment of station blackout accident and 5th emergency diesel in Daya Bay NPP  

International Nuclear Information System (INIS)

In this paper, probabilistic safety assessment (PSA) of the station blackout (SBO) and 5th emergency diesel in Daya Bay NPP has been carried out, the calculation method of non-recover factors of power supplies is given, and sensitivity analysis on the connection duration of 5th emergency diesel has been executed. It is concluded that the core damage frequency (CDF) induced by SBO is relatively large, the addition of 5th emergency diesel is very helpful for the CDF reduction, and the connection duration of this diesel has great effect on the CDF reduction

2004-08-01

222

Power generation growth to triple LNG use  

Energy Technology Data Exchange (ETDEWEB)

Taiwan`s LNG consumption is planned to rise more than threefold over the next four years as medium-term plans to develop power generation facilities increasingly rely on gas-fired combined-cycle stations to avoid the threat of power shortages. State-run Taiwan Power Company (Taipower) expects its LNG consumption to rise from 1.1 mn tonnes in 1996 to 3.4 mn tonnes in the year 2000. By then the first of several gas-fired private power stations is expected to enter service, further increasing Taiwan`s total LNG requirement for power generation. (Author)

1997-11-01

223

NPD Canada's first nuclear power station  

Energy Technology Data Exchange (ETDEWEB)

This talk reviews the history of the Canadian nuclear-electric program highlighting Canada's first nuclear power station, the Nuclear Power Demonstration or NPD. NPD was commissioned and delivered electricity to Canadian consumers for the first time on june 4, 1962. The Canadian nuclear-electric program is based on the CANDU-PHW (Canadian Deuterium Uranium - Pressurized Heavy Water) concept which was conceived between 1955 and 1958 at the Chalk River Nuclear Laboratory (CRNL) of AECL, located a few miles from Deep River. This talk covers the history of the Canadian nuclear-electric activities dating back to 1939.

2002-07-01

224

Leadership, communication and decision making in man-machine systems; Fuehrung, Kommunikation und Entscheidungsfindung in Mensch-Maschine-Systemen  

Energy Technology Data Exchange (ETDEWEB)

The contribution under consideration spans a wide curve from the first deadly accident of motorized aviation in the year 1908 up to newer tendencies of the so-called team resources management on observation points and control stations in order to pursue fundamental questions in man-machine systems. A continuous differentiation in the consideration of the factor human beings in complex technical systems is described. This is illustrated by the example of concepts for leadership, communication and decision making on observation points and control stations.

2008-07-01

225

GT13E gas turbines to power Killingholme A GTCC [gas turbine combined-cycle] plant  

Energy Technology Data Exchange (ETDEWEB)

National Power is building its first gas turbine combined cycle power station at Killingholme, situated to the south of the River Humber in the East of England. NEI ABB Gas Turbines Limited was awarded the turnkey contract in July 1990 to build a nominal 650 MW combined cycle power station based around three Asea Brown Boveri GT13E gas turbines. The project is outlined in this article. The plant is due for completion in July 1993. (author)

1993-01-01

226

Feasibility study on scheme of disposing spent guide tubes at Daya Bay nuclear power plant  

International Nuclear Information System (INIS)

The author describes feasibility study on the scheme of disposing spent guide tubes at Daya Bay nuclear power plant, including scheme selection, packing cask design, disposal operation and technological process, budget estimation and safety evaluation. The research results show that the new scheme is feasible on technology, and reasonable on budget. If the scheme is adopted to dispose the spent guide tubes at Daya Bay nuclear power station, it can not only save large funds, but also accumulate experience on disposing non-compressible low and intermediate level solid radioactive wastes produced at nuclear power station for the country

1998-12-01

227

Electricity supply in Germany  

Energy Technology Data Exchange (ETDEWEB)

Data on various aspects of the electric power industry in Germany is presented in this article. A map of high voltage transmission lines used by the public utilities is included, which indicates the fuel used at each power station. Data on power generated by fuel used from 1991 to 1996 is given, and additional or new capacity for 1995 to 1999 is also noted. Other tables detail capital investment in public utilities energy input by fuel source, power capacity by utility or private power stations by energy source, utility ownership and electricity demand by consumer. (UK)

1997-09-01

228

Electric power production from the biogas resulting of the sewer treatment: pilot project of the Sewer Treatment Station (ETE) in the Barueri city in the Great Sao Paulo; Producao de energia eletrica a partir do biogas resultante do tratamento de esgoto: projeto piloto na E.T.E. de Barueri na Grande Sao Paulo  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a system for biogas conversion to electric power and heat by using a micro turbine and three Otto cycle engines. The benefit of the energy from a treatment process residue aims the improvement of the global performance of the system, reducing the the emission of the greenhouse gases and contributing to the global energetic efficiency of the sewage treatment station and the basic sanitation in Brazil.

2002-07-01

229

Dampers, fluidics and the failsafe fallacy [fire protection  

International Nuclear Information System (INIS)

The fire protection practices adopted at nuclear power stations generally follow the well established principles used throughout industry. Unfortunately, there is one particular area - the interaction with heating, ventilation and air conditioning (HVAC) services - where nuclear power stations pose a seemingly insoluble conflict: that between the need to contain and the need to ventilate. Now, however, solid state fire dampers using power fluidics may promise a solution. One of the key characteristics of a fluidic device is that it is 'solid state', i.e. it has no moving parts. Because of this, its inherent reliability is orders of magnitude greater than a mechanical device. (U.K.).

230

Conservation of power station components during standstill by means of dry air  

International Nuclear Information System (INIS)

The use of pre-dehumidified air having widely established itself as a safe and economical conservation method during the stoppage of steam turbines, it was obvious that this method would be applied also to steam boilers and ancillary aggregates. Experience with the conservation of condensers, prheaters and the water/steam-side of steam boilers in large-scale power stations is reported on. By the example of projects with topical interest, the problems and possibilities of boiler conservation on the firing side are illustrated. The contribution is to stimulate further discussions. (orig.).

231

Comparison and analysis of results of ? radiation level investigation around Daya Bay  

International Nuclear Information System (INIS)

Investigations were carried out of radiation level around Daya Bay for three times since the construction and operation Daya bay Nuclear Power Station and Lingao Nuclear Power Station in Guangdong province in the period of 1988 to 2000. As shown by the investigation, the radiation levels both in the field and indoors remains unchanged by and large but slightly higher than before on the roads. Also this paper gives the analysis of variations in radiation levels form site to site and from time to time. It was shown that, for environmental ? radiation levels measurements, typical measuring sites have significant impact on the meaning results. (authors)

2003-08-01

232

Biotoxicity characterization of a produced-water discharge in Wyoming  

International Nuclear Information System (INIS)

The objectives of this paper are to document the physicochemical and aquatic toxicological quality of a beneficial-use produced-water discharge and its effect on a receiving stream in Wyoming. Fish and water-flea survival, growth, and reproduction tests indicated that the discharge and all other sampling stations passed the state effluent biomonitoring acute toxicity testing endpoints. while benthic macroinvertebrates were absent at the discharge point designated by the Natl. Pollutant Discharge Elimination System (NPDES), productive and reproducing populations were present at all other downstream and mixing-zone stations. This investigation confirmed the validity of the beneficial-use subcategory for this oilfield discharge.

233

Application of power system stabilizer at Bandar-Abbas power station  

Energy Technology Data Exchange (ETDEWEB)

System instability as result of high power generation of one of the largest plants of the Iranian electric power grid prevented the plant to be fully utilized. PSSs were installed on the generating units of the power station, to improve its small signal stability, and enhance the stable generation limit. Domain separation and pole assignment techniques were applied for the PSS design. Several field tests were also carried out to verify its effectiveness. This paper presents the PSS tuning procedure, including the design criteria and some of the field test results.

1994-08-01

234

Accident assessment under emergency situation in Daya Bay nuclear power station  

International Nuclear Information System (INIS)

The accident assessment under emergency situation includes the accident status evaluation and its consequence estimation. This paper introduces evaluation methods for accident status and its assistant computer system (SESAME-GNP) utilized during the emergency situation in Guangdong Daya Bay Nuclear Power Station (GNPS) in detail. At the same time, an improved accident consequence estimation system in GNPS (RACAS-GNP) is briefly described. With the improvement of the accident assessment systems, the capability of emergency response in GNPS is strengthened

2004-05-01

235

A new procedure for cutting out the broken thermocouple tubes inside the deep holes in the tube plate of moisture re-heater at Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

The scenario of the development of a new procedure for cutting out the broken protective wells for thermocouples inside the deep holes in the tube plate in the moisture re-heater (MSR) at Daya Bay nuclear power station is presented. Focused in the innovation and improvement of the self-made tools, the new procedure produced an effective method to cut out swing long inserts stuck inside the deep holes. (authors)

2005-09-01

236

Outline of design and construction of civil engineering work for Higashi-Niigata thermoelectric power station No.4 system; Higashiniigata karyoku hatsudensho yongo keiretsu doboku koji no sekkei to seko no gaiyo  

Energy Technology Data Exchange (ETDEWEB)

Tohoku Electric Power Co., Ltd., is now building an LNG-fired No. 4 System (combined cycle of 1.61-million kW) for its Higashi Niigata Thermoelectric Power Station sited in the Niigata East Harbor industrial zone. This is a unit that aims at a thermal efficiency of 50% first in the world by using high-efficiency gas turbines, etc. After the completion of the No. 4 System, the station (No. 1 Machine, No. 2 Machine; No. 3 System, No. 4 System; Harbor No. 1 Machine, Harbor No. 2 Machine) will be generating a total power of 4.6kW, providing the company with its maximum power source which ranks among the largest-grade thermoelectric power stations in this country. Since the construction work was started in April, 1996, approximately 40% had been completed as of March-end, 1997, including foundations for the power station main building, stack, etc. The power station main building uses a ...

1997-07-05

237

Air quality monitoring report for Alberta, 1991  

Energy Technology Data Exchange (ETDEWEB)

In 1991, the air quality monitoring program in Alberta consisted of continuous, intermittent, static, portable, mobile, and acid precipitation monitoring networks. The air quality monitoring networks are described and results from the continuous, intermittent, static, and acid precipitation networks are summarized. Regulations and guidelines for individual pollutants are discussed in detail. Pollutants monitored continuously (1-h average basis) include ammonia, CO, coefficient of haze, H{sub 2}S, nitrogen oxides, ozone, SO{sub 2}, and total hydrocarbons. Good air quality was observed most of the time at all continuous monitoring stations in 1991. The frequency of good air quality ratings ranged from 81% at the Edmonton northwest station to 98% at the Fort McMurray station. Intermittent monitoring (every 6th day) was conducted for total suspended particulates and for vinyl chloride monomers in the Fort Saskatchewan area. ...

1993-08-01

238

Station blackout induced severe accident analysis for Daya Bay NPP  

International Nuclear Information System (INIS)

In Aug 2002, the National Nuclear Safety Administration of China issued the policy statement for building new nuclear power plants, which requires the probability based safety goal of severe core damage must be lower than 10"-"5/a. The station blackout accident would be possible to cause a severe accident if there were no effective engineering measures to prevent or mitigate the consequences of the accident. By using MELCOR1.8.5 and KORIGEN codes, the present paper has simulated the station blackout accident for Daya Bay Nuclear Power Plant and calculated the source term and radioactivity of main fission products in the containment in the late phase of the accident. CsI is found the main part of aerosol in the containment. The Xe133 and Xe133m start releasing from the containment after its failure, and the upper limit of the amount of released radioactivity is evaluated less than 5.5 x 10"1"5Bq. The total radioactivity of other significant ...

2004-10-04

239

Sea-to-sky airshed ambient quality monitoring report : 1984-2001  

Energy Technology Data Exchange (ETDEWEB)

This report provides information to government and industry to enable decision-making and management of local environmental quality conditions. The need for a summary air quality report has arisen in recent years due to growing concerns about air quality. Increased growth in population and the tourism industry is placing additional pressures on environmental quality. The report summarized meteorological and air quality data collected by the British Columbia Ministry of Water, Land and Air Protection in the Sea-to-Sky airshed from 1984 to 2001. The airshed is located in the Lower Mainland region of British Columbia. Air quality monitoring was conducted for various periods at 18 different stations and meteorological monitoring was conducted at 4 locations. A list of both provincial and national air quality objectives and standards was provided, with definitions and reference levels from the Canadian Environmental Protection Act. Meteorological data was presented on a ...

2004-09-01

240

Results of a cross-sectional study on the association of electromagnetic fields emitted from mobile phone base stations and health complaints; Ergebnisse einer Querschnittsstudie zum Zusammenhang von elektromagnetischen Feldern von Mobilfunksendeanlagen und unspezifischen gesundheitlichen Beschwerden  

Energy Technology Data Exchange (ETDEWEB)

Background: Despite the fact that adverse health effects are not confirmed for exposure to radiofrequency electromagnetic field (RFEMF) levels below the limit values, as defined in the guidelines of the International Commission on Non-Ionizing Radiation Protection, many persons are worried about possible adverse health effects caused by the RF-EMF emitted from mobile phone base stations, or they attribute their unspecific health complaints like headache or sleep disturbances to these fields. Method: In the framework of a cross-sectional study a questionnaire was sent to 4150 persons living in predominantly urban areas. Participants were asked whether base stations affected their health. Health complaints were measured with standardized health questionnaires for sleep disturbances, headache, health complaints and mental and physical health. 3,526 persons responded (85%) to the questionnaire and 1,808 (51%) agreed to dosimetric measurements in ...

2010-07-01

241

Initial results of the CD-1 reliable multicast experiment  

Energy Technology Data Exchange (ETDEWEB)

During the past year, an experiment has been underway to test use of reliable multicast capabilities for transmission of continuous data in the Global Communication Infrastructure. For the experiment a version of the CD-1 protocol was multicast enabled. The experiment has demonstrated the feasibility of transmitting data in a multicast mode over the GCI. In the case of the Comprehensive Nuclear Test-Ban Treaty the sender could be the station and the receivers the International Data Center (IDC) and one or more National Data Centers (NDC). The potential advantages of multicasting include (a) the timely receipt of the data by the IDC and the host NDC and (b) the simultaneous availability of the raw station data at, at least, two locations. The latter, by introducing redundant data paths, decreases the probability of loss of station data due to a potential failure of a single data receiver. This experiment is only one element ...

2000-09-29

242

Collective effective dose equivalent, population doses and risk estimates from occupational exposures in Japan  

Energy Technology Data Exchange (ETDEWEB)

Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. The resultant doses were compared with the ...

1993-05-01

243

Collective effective dose equivalent, population doses and risk estimates from occupational exposures in Japan  

International Nuclear Information System (INIS)

Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. The resultant doses were compared with the ...

1993-01-01

244

Wood-gas / natural-gas combined-cycle power station for Switzerland - Potential and estimation of financial viability; Holzgas/Erdgas-Kombikraftwerk fuer die Schweiz: Potenzial und Wirtschaftlichkeitsabschaetzung. Input-Papier fuer die Stromangebots-Perspektiven 2035 des Bundesamts fuer Energie  

Energy Technology Data Exchange (ETDEWEB)

This paper was produced as an input to the Swiss Confederation's 'Electricity Perspectives 2035' study made by the Swiss Federal Office of Energy (SFOE). A concept for the combined use of wood and natural gas in a combined-cycle power station is presented. The gasification of wood to provide fuel for the gas turbines and waste-heat boilers of such power stations is proposed as an alternative to just burning wood to provide heat for steam generators. Figures are quoted on the quantities of biomass and wood usable for energy applications in Switzerland. The energetic and financial efficiencies of wood-powered generation of heat and electricity are examined, as are the investments necessary and the costs incurred. Comparisons are presented between wood from forests, sawmill-wastes, scrap wood and natural gas as fuels.

2005-07-01

245

Wire pad chamber for LHCb muon system  

CERN Document Server

2000-003 Wire pad chambers (WPC) have been proposed for the outer Region 4 of the LHCb Muon System. These are double gap MWPCs with small wire spacing allowing to obtain 99% detection efficiency in a 20 ns time window. The chambers have a rectangular shape with the vertical dimension from 20 cm in Station 1 to 30 cm in Station 5. The horizontal dimensions will be different with the maximal size of 3 meters in Station 5. The wires are in the vertical direction. The short wire length allows to use small wire spacing needed for high time resolution. Also, this helps to obtain the uniform gas gain over the whole chamber area. The WPC has one row of the wire pads formed by grouping wires in separate readout channels. Four WPC prototypes have been built at PNPI and tested in the PS beam at CERN. Here we report on the results from these tests. Also, the results of simulation of the WPC performance are presented.

2000-01-01

246

Study of dose rates and radionuclides contributing to dose rates in India's 540 MWe pressurised heavy water reactors  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station Unit-3 and 4 (TAPS -3 and 4) are the 540 MWe reactors. Unit-4 attained first criticality on 06th March 2005 and operated for about 230 effective full power days (EFPD). Unit-3 attained first criticality on 21st May 2006 and operated for about 20 EFPD. With the reactor operation radiation field increases on the Primary Heat Transport system equipments, Moderator system equipments and auxiliary system equipments due to deposition of fission products and activation products in different reactor systems. These dose rates significantly contributes to the external exposure and stations collective dose during reactor operation, refueling operation and maintenance activities. A study was undertaken at TAPS 3 and 4 to identify the system equipments showing the significant dose rates and identify the radionuclides present in the primary heat transport system, Moderator systems, cover gas system and other auxiliary system for ...

2006-11-13

247

Straw-fuelled heating power stations in Denmark; Strohheizkraftwerke in Daenemark  

Energy Technology Data Exchange (ETDEWEB)

During the past 15 years, 60 straw-fuelled and 25 wood-fuelled district heating stations were commissioned in Denmark, as well as 6 biomass-fuelled heating power stations. All of these plants are equipped with high-pressure boilers, heat exchangers for district heating, and steam turbines with generators. Today, 5 percent of the total energy consumed is provided by biomass fuels. With the new taxes on carbon dioxide emissions and measures to promote renewable energy sources, a 15 percent share can be expected soon. (orig/SR) [Deutsch] In Daenemark wurden in den letzten 15 Jahren 60 strohbefeuerte und 25 holzbefeuerte Fernwaermewerke in Betrieb genommen. Dazu sind in den letzten Jahren 6 biomassebefeuerte Heizkraftwerke gekommen. Alle Anlagen haben Hochdruckkessel, Waermetauscher fuer Fernwaerme und Dampfturbinen mit Generatoren. Heute werden in Daenemark 15 Prozent des Energieverbrauchs mit Biomasse gedeckt. Durch Besteuerung der ...

1996-12-31

248

Seabrook Station Level 2 PRA Update to Include Accident Management  

Science.gov (United States)

A ground-breaking study was recently completed as part of the Seabrook Level 2 PRA update. This study updates the post-core damage phenomena to be consistent with the most recent information and includes accident management activities that should be modeled in the Level 2 PRA. Overall, the result is a Level 2 PRA that fully meets the requirements of the ASME PRA Standard with respect to modeling accident management in the LERF assessment and NRC requirements in Regulatory Guide 1.174 for considering late containment failures. This technical paper deals only with the incorporation of operator actions into the Level 2 PRA based on a comprehensive study of the Seabrook Station accident response procedures and guidance. The paper describes the process used to identify the key operator actions that can influence the Level 2 PRA results and the development of success criteria for these key operator actions. This addresses a key requirement of the ASME PRA Standard for ...

2006-07-01

249

Seabrook Station Level 2 PRA Update to Include Accident Management  

International Nuclear Information System (INIS)

A ground-breaking study was recently completed as part of the Seabrook Level 2 PRA update. This study updates the post-core damage phenomena to be consistent with the most recent information and includes accident management activities that should be modeled in the Level 2 PRA. Overall, the result is a Level 2 PRA that fully meets the requirements of the ASME PRA Standard with respect to modeling accident management in the LERF assessment and NRC requirements in Regulatory Guide 1.174 for considering late containment failures. This technical paper deals only with the incorporation of operator actions into the Level 2 PRA based on a comprehensive study of the Seabrook Station accident response procedures and guidance. The paper describes the process used to identify the key operator actions that can influence the Level 2 PRA results and the development of success criteria for these key operator actions. This addresses a key requirement of the ASME PRA Standard for ...

2006-06-04

250

Scaling Laws and Design Principles for Multi-Cellular Wireless OFDMA Systems  

CERN Document Server

In this paper, we consider the downlink of large-scale multi-cellular OFDMA-based networks and study performance bounds of the system as a function of the number of users $K$, the number of base-stations $B$, and the number of resource-blocks $N$. Here, a resource block is a collection of subcarriers such that all such collections, that are disjoint have associated independently fading channels. We derive novel upper and lower bounds on the sum-utility for a general spatial geometry of base stations, a truncated path loss model, and a variety of fading models (Rayleigh, Nakagami-$m$, Weibull, and LogNormal). We also establish the associated scaling laws and show that, in the special case of fixed number of resource blocks, a grid-based network of base stations, and Rayleigh-fading channels, the sum information capacity of the system scales as $\\Theta(B \\log\\log K/B)$ for extended networks, and as $O(B \\log\\log K)$ and ...

2011-01-01

251

Preliminary study of the effect of pumped-storage plant operation on zooplankton  

Energy Technology Data Exchange (ETDEWEB)

The hydromechanical effect of hydroelectric stations on zooplankton is customarily regarded as a constantly acting and comparatively harmless factor, since its destruction is inevitable when water masses are passed through hydroelectric stations, but its capacity for restoration is high (i.e., destruction of the zooplankton of the forebay is compensated by its production in the after bay). It is not known how correct such an opinion is, or what is the true balance of losses and reproduction of zooplankton in the forebays and after bays of hydroelectric stations. However, hydroelectric plants of a new type, pumped-storage plants, have been constructed in recent years and others are planned for the Dnieper reservoirs. The operational principle and purpose of these plants is that they employ special vertical turbine-electric pumps that pump water at night from the reservoirs into pumped-storage facilities at high levels, and ...

1980-01-01

252

Physical research of microgravity influence on physical phenomenon in cryogenic liquids and general-purpose onboard cryogenic facility for realization of this research aboard International Space Station  

International Nuclear Information System (INIS)

The united research plan named 'Boiling' is created on the basis of several cryogenic research projects developed by experts in Russia and Ukraine for International Space Station. The 'Boiling' plan includes 8 first experiments aimed at investigating the influence of microgravity on boiling processes, heat transfer and hydrodynamics in liquid helium being either under normal or superfluid conditions. The experiments are supposed to be carried out with individual cells collected inside a single cryogenic onboard experimental facility. The international research program experiments are characterized by the following features: utilization of several artificially simulated microgravity levels, owing to rotation of the experimental helium cryostat; visualization of the processes that occur in liquid helium; research of boiling and hydrodynamics both in a large volume of stationary liquid, and in a liquid flow running through a channel. Upon completion of the 'Boiling' ...

2003-06-01

253

Optimization of maintenance programme at Daya Bay Nuclear Power Station based on RCM analysis results  

International Nuclear Information System (INIS)

This paper begins with an introduction to Guangdong Daya Bay Nuclear Power Station (GNPS) and gives a simple introduction to the operations and maintenance documentation system at GNPS. It then will review the maintenance program guidelines base and the associated problems prior to the application of reliability centered maintenance (RCM). How RCM was implemented at GNPS, how the results of RCM analysis were used to optimize the maintenance program and test program, and what is the interface between RCM and the existing maintenance program will be shown. Next, it will show the successful implementation of RCM at GNPS resulted in the following changes: A new understanding of equipment failure challenges operations and maintenance beliefs, maintenance concepts undergo a large change, maintenance program and periodic testing program are continuously modified and optimized, new on-condition maintenance technologies are introduced, non-productive scheduled overhauls are ...

2003-12-01

254

On important matters (fire protection) related to No. 3 plant in the Hamaoka Nuclear Power Station, Chubu Electric Power Co., Inc., No. 2 plant in the Tsuruga Power Station, Japan Atomic Power Co., and No. 2 plant in the Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc  

International Nuclear Information System (INIS)

The Nuclear Safety Commission acknowledged the policy of the Agency of Natural Resources and Energy to cope with these important matters on August 8, 1984. The main contents of the investigation and deliberation were as follows, As to the prevention of the occurrence of fires, the prevention of the leak and spread of inflammable liquid and gas, the installation of protective relays and so on, the use of incombustible materials and aseismatic design and the installation of lightning arresters. As to the detection of fires and fire fighting, the proper selection and arrangement of fire detectors and extinguishers, the extinguishers which do not harm the safety function of structures and equipment, and the extinguishers which are not affected by natural phenomena. As to the reduction of the effect of fires, the proper installation of fire walls and extinguishers, and the high temperature shut off of nuclear reactors which is never hampered by any fire. (Kako, I.).

1985-01-01

255

Localization explore of electrical and I and C equipments in Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

The supply of electronic instrumentation and controlling (I and C) equipments in Daya Bay Nuclear Power Station depends on importation up to now, however, reliable supply of spare parts is presently threatened by many factors. Consequently, Daya Bay Nuclear Power Station tries to localize these equipments. According to a survey, China has possessed the ability to undertake the research, development and production of the I and C system in nuclear power independently. We propose that localization should firstly starts with the production of replacement board and parts for analogical I and C system, gradually leads to the substitution of system cabinet units, and finally realize the independent research, development and production of advanced digital main control system. A series of prominent problems of producing nuclear grade I and C equipments are focused on the designing, manufacturing, testing and reliability evaluation. In this paper, ...

2007-10-01

256

Dynamic load in suppression pool during BWR main steam safety relief valve actuation  

International Nuclear Information System (INIS)

BWRs are so designed that the exhaust steam from main steam safety relief valves is led to pressure suppression pools, and the steam is condensed in pool water, but at this time, dynamic load seems to arise in the pool water. In Tokai No. 2 Power Station, a Mark-2 containment vessel was adopted to improve the reliability as much as possible and to obtain the design with margin. In this report, the result of actual machine test in Tokai No. 2 Power Station and the method of reducing the load are described. When a relief valve works, the discharge of water in exhaust pipes into a suppression pool, the exhaust of air in exhaust pipes and repeated expansion and contraction of bubbles in pool water, and the exhaust of steam and condensation occur. As for the construction of the suppression pool in Tokai No. 2 Power Station, cross-shaped quencher and the structure with jet deflector were installed. The test plan and the test ...

1979-01-01

257

Design modifications in 540 MWe and its impact on the dose rates  

International Nuclear Information System (INIS)

Exposure control at the operating Nuclear Power Station is a major concern. TAPS Unit-4 is the first Pressurized Heavy Water Reactor of 540 MWe electrical capacity. This unit was made critical on March 6, 2005. In-depth review of radiation safety was done to identify the impact of design modification on dose rates at various locations and on the equipment's. Problems encountered in controlling the dose rates in 220 MWe electrical are eliminated by appropriate design modifications. Due to higher capacity of the unit there are design changes in major systems such as reactor core, primer heat transport system, moderator system, reactor regulation and protection systems. Reactor operations and maintenance activities during shut down contributes to exposure of the employees. Based on the experience gained in the operation of 220 MWe, design modifications incorporated in TAPS unit-4 and dose rate measurements carried out at 90 % full power, through this paper attempt is ...

2005-11-23

258

Daya Bay Nuclear Power Station five-year business plan and operating results  

International Nuclear Information System (INIS)

Guangdong Nuclear Power Joint Venture Company, Ltd. first 5-Year Business Plan (hereinafter referred to as 5-Year Business Plan) serves as guidance of both the operations and management of the company. Continuous performance improvement of the nuclear power station has been achieved through the fulfillment of goals and improvement plan defined by the 5-Year Business Plan, and through standard and systematic management. Daya Bay Nuclear Power Station (GNPS) has made great contributions to sustainable economic developments of both Guangdong and Hong Kong since its commercial operation in 1994. As of the end of 1999, the cumulative off-take electricity generated by GNPS had reached 69.9 billion kWh. Of the WANO indicators universally applied by nuclear power industry throughout the world, 6 indicators of Daya Bay performance entered the world top quartile while 9 the medium level

2000-12-05

259

Cogeneration process for small and medium-sized industrial plants; CO-Generation-Process fuer kleinere und mittlere Industrieanlagen  

Energy Technology Data Exchange (ETDEWEB)

Industrial companies are being forced by increasingly restrictive environmental legislation to implement power station technology which is environmentally compatible and which conserves scarce resources. Gas and steam turbine power stations have been causing a sensation in this field for some time. This article gives an introduction to gas and steam turbine power stations in the 4 MW to 30 MW size range. The designs of the plants described here not only provide for electricity generation by gas and steam turbines however, but also designs specific to particular companies for process steam and district heating supply. (orig.) [Deutsch] Durch immer restriktivere Umweltschutzgesetze werden die Industrieunternehmen zu einer umwelt- und ressourcenschonenden Kraftwerkstechnik gedraengt. Auf diesem Gebiet sorgen nun seit geraumer Zeit GuD-Kraftwerke fuer Furore. In diesem Beitrag werden GuD-Kraftwerke in einer Groessenordnung ...

1993-12-31

260

Breakdowns of high-voltage transmission lines due to sea-salt deposits on insulators  

Energy Technology Data Exchange (ETDEWEB)

Until 1990, in Tuscany, salt pollution of anti-salt insulators installed on high-tension transmission lines had led to rare breakdowns. On the contrary, in the last months of 1990, in most of Tuscany, following a strong libeccio wind coming from the Tyrrhenian Sea, and due to a long period of drought, salt deposits accumulated on the insulators of the high-voltage transmission lines (380 kV, 220 kV and 132 kV). This phenomenon not only took place in the coastal areas near Livorno, Pisa and Grosseto, but also in areas far away from the sea such as Florence, Prato, Arezzo and Siena. Following this, several high-tension lines, and whole sections of 380 kV electric stations went out of order, damaging the stations' equipment, insulators on the lines, and in particular porcelain insulators. The maintenance operations that were immediately undertaken consisted in washing operations, first focussed on stations, and then ...

1992-03-01

261

Breakdowns of high-voltage transmission lines due to sea-salt deposits on insulators  

International Nuclear Information System (INIS)

Until 1990, in Tuscany, salt pollution of anti-salt insulators installed on high-tension transmission lines had led to rare breakdowns. On the contrary, in the last months of 1990, in most of Tuscany, following a strong libeccio wind coming from the Tyrrhenian Sea, and due to a long period of drought, salt deposits accumulated on the insulators of the high-voltage transmission lines (380 kV, 220 kV and 132 kV). This phenomenon not only took place in the coastal areas near Livorno, Pisa and Grosseto, but also in areas far away from the sea such as Florence, Prato, Arezzo and Siena. Following this, several high-tension lines, and whole sections of 380 kV electric stations went out of order, damaging the stations' equipment, insulators on the lines, and in particular porcelain insulators. The maintenance operations that were immediately undertaken consisted in washing operations, first focussed on stations, and then on lines. ...

1992-01-01

262

Aerial radiological survey of the Grand Gulf Nuclear Station and surrounding area, Port Gibson, Mississippi. Date of survey: March 1982  

International Nuclear Information System (INIS)

An aerial radiological survey was performed from 11 to 20 March 1982 over a 260-square-kilometer area centered on the Grand Gulf Nuclear Station at Port Gibson, Mississippi (the station was not yet in operation at the time of the survey). All gamma ray data were collected by flying east-west lines spaced 152 meters apart at an altitude 91 meters above ground level. Processed data showed that all gamma rays detected within the survey area were those expected from naturally occurring terrestrial background emitters. Count rates obtained from the aerial platform were converted to exposure rates at 1 meter above the ground and are presented in the form of an isoradiation contour map. The observed exposure rates were between 5 and 13 microroentgens per hour (#mu#R/h), with most of the area ranging from 9 to 10 #mu#R/h. These values include an estimated cosmic ray contribution of 3.6 #mu#R/h. The exposure rate obtained from soil samples and ...

263

A microcontroller-based data-acquisition system for meteorological station monitoring  

International Nuclear Information System (INIS)

This paper presents a study of feasibility of different existing methodologies linked to field's data acquisition from remote meteorological stations. The data transmission serves to collect field's meteorological information, such as temperature, humidity and radiation. In our study the experimental data is registered in a weather station located about 100 km from University of Almeria. Various existing techniques are studied, especially Radio, GSM (global system of mobile communication) and GPRS (general packet radio service). In the result of these studies has been designed a system of field's data acquisition (herein referred as Meteologger) which we are going to present in this paper. The system is based on an ATmega 16 microcontroller, which scans 8 sensors together at any programmable intervals. This paper presents the study of the mentioned project, application and some main characteristics of the prototype system and its program. We ...

2008-12-01

264

{sup 222}Rn as indicator of atmospheric turbulence: measurements at Lake Maggiore and on the pre-Alps  

Energy Technology Data Exchange (ETDEWEB)

Radon concentration measurements in atmosphere were taken in years from 1997 to 1999 in Milan and at pre-alpine sites located north of Lombardy. In this paper the results of measuring campaigns and a comparison of radon levels observed in the hilly area north of the town and on the pre-Alps are reported. The general criteria of the measurements and the interpretative models of radon concentration are presented. The Lake Maggiore area shows evidence of a great nocturnal stability and frequent formation of Nocturnal Stable Layer. The peculiar findings in the high altitude stations confirm the use of radon as an indicator of atmospheric dispersion of pollutants in an area with complex orography. The afternoon minimum values are concordant for the different stations: this implies a remixing in afternoon hours over the whole area investigated.

2006-07-01

265

Use of portable HPGE detector and multichannel analyzer for in-situ gamma spectrometry of soil  

International Nuclear Information System (INIS)

Measurement of fission and activation products in the soil or over a plane grass land of a nuclear power station environment is required to find out the long term changes. The inventory of radionuclides in the soil is routinely determined by soil sampling, processing and gamma spectrometry in the laboratory. The method although is proven and accurate is time consuming and largely dependent on homogenous distribution. Therefore, an alternative and rapid method of in-situ gamma spectrometry using portable devices was standardized to determine the concentration of radionuclides in soil, for regular environmental monitoring as well as during emergency condition. The paper presents the methodology, ready to use factors and compares the results of a few measurements made in the environment of Tarapur Atomic Power Station by both in-situ and laboratory methods. (author)

2005-11-23

266

The development of open-pore multi-layer systems for steam turbines operating with 700 C technology; Die Entwicklung offenporoeser Mehrschichtsysteme fuer Dampfturbinen der 700 C-Technologie  

Energy Technology Data Exchange (ETDEWEB)

In the context of the special research area 561 (Thermally highly loaded, open-porous and cooled multi-layer systems for combined-cycle power stations), the actual technical and scientific realizations are to be extended and new scientific bases are to be created in order to realize total efficiencies of 65 %. In addition, innovative material solutions and new concepts must be compiled for the cooling and drainage. Under this aspect, the author of the contribution under consideration reports on the development of open-porous multi-layer systems for steam turbines of the 700 C technology. It results an efficiency potential of 12 % and a potential of 15 % with the reduction of CO{sub 2} in relation to the actual state of the art. Thereby, the potential of future combined-cycle power stations is not yet exhausted.

2008-07-01

267

The SOS-LUX-TOXICITY-Test on the International Space Station  

British Library Electronic Table of Contents (United Kingdom)

For the safety of astronauts and to ensure the stability and integrity of the genome of microorganisms and plants used in bioregenerative life support systems, it is important to improve our knowledge of the combined action of (space) radiation and microgravity. The SOS-LUX-TOXICITY test, as part of the TRIPLE-LUX project (accepted for flight at Biolab in Columbus on the International Space Station, (ISS)), will provide an estimation of the health risk resulting from exposure of astronauts to the radiation environment of space in microgravity. The project will: (i) increase our knowledge of biological/health threatening action of space radiation and enzymatic DNA repair; (ii) uncover cellular mechanisms of synergistic interaction of microgravity and space radiation; (iii) provide specified...

2006-01-01

268

Summarization of radioactive effluent monitoring in Daya Bay Nuclear Power Station 1994-2002  

International Nuclear Information System (INIS)

This paper introduces the radioactive effluent monitoring systems, measurement and quality control methods used in Daya Bay Nuclear Power Station from its commercial operation in 1994. The main work and experiences for the management of effluent release are discussed and analyzed. The radwaste data appear declining trend and are far blow the annual limit approved by the national Environmental Protection Bureau since 1995. The normalized release (unit GBq/GWa) of 9 years is as follows: liquid nuclides (except tritium) 11.1, liquid tritium 1.91 x 10"4, noble gas 2.03 x 10"4, halogen 0.13, aerosol 7.57 x 10"-"3. For "1"1"0"mAg, the average release from 1998 to 2002 has been reduced to 1/7 of the quantity in 1997

2004-05-01

269

Safety evaluation report related to the operation of Grand Gulf Nuclear Station, Units 1 and 2. Dockets Nos. 50-416 and 50-417, Mississippi Power and Light Company; Middle South Energy, Inc. , South Mississippi Electric Power Association  

Energy Technology Data Exchange (ETDEWEB)

Supplement 2 to the Safety Evaluation Report for Mississippi Power and Light Company, et. al, joint application for licenses to operate the Grand Gulf Nuclear Station, Units 1 and 2, located on the east bank of the Mississippi River near Port Gibson, in Claiborne County, Mississippi, has been prepared by the Office of Nuclear Reactor Regulation of the US Nuclear Regulatory Commission. This supplement reports the status of certain items that had not been resolved at the time of publication of the Safety Evaluation Report.

1982-06-01

270

Quality control and evaluation for environmental radiological baseline study of Guangdong Daya Bay nuclear power station  

International Nuclear Information System (INIS)

The main points of quality control methods and technique of environmental radiological baseline study of Guangdong Daya Bay Nuclear Power Station are reported. Results of intercalibration of international and inland laboratories are given. The random chosen samples are checked and compared with two measurement methods. The data obtained in Daya Bay environment are put to the correlation statistics test using the linear regression analysis method between the correlative items such as "4"0K activity by gamma spectrum measurement and potassium content by chemical analysis, total #alpha#(#beta#) activity and nuclide content, as well as environmental gamma radiation dose rate and TLD accumulation dose. The data of Daya Bay environmental radioactivity baseline level show good concordance and reliability.

271

Process for producing calcium sulfate dihydrate during desulfurization of stack gases from power station boilers. Verfahren zur Herstellung von Calciumsulfat-Dihydrat im Zuge der Entschwefelung von Rauchgasen aus Kraftwerkskesselfeuerungen  

Energy Technology Data Exchange (ETDEWEB)

This is a process for producing calcium sulfate dihydrate during desulfurization of stack gases from power station boilers, where the stack gases are introduced into a washing tower and are treated with a washing water suspension containing lime in the washing tower, where oxygen in the form of air or of air enriched in oxygen is also blown into the washing tower, and where the washing water suspension drawn off from the washing tower is fed back to the washing tower at a temperature of 45 to 50/sup 0/C in the circuit and at least part of the flow goes via a thickener and where calcium sulfate dihydrate slurry is drawn off from the thickener.

1986-06-12

272

Problem of microelements in the combustion, gasification and hydrogenation of coals  

Energy Technology Data Exchange (ETDEWEB)

Role of microelements in coal in connection with their combustion in power stations, gasification and hydrogenation is discussed from the standpoint of environmental pollution and effects on technological parameters. In the wastes from fossil-fuel power stations there are biogenic and toxic elements (Be, B, Pb, etc.) present, which eventually go into the soil. Analyses showed that coal from the Kuznetsk, Donetsk, Ehkibastuz and Kansk-Achinsk basins which are used for power, have a relatively low level of biogenic and toxic microelements, e.g. Ba, B, Mn, Pb, Co, Ni, V, Cu, Y. Coal reactivity in gasification and hydrogenation is discussed. The catalytic effect of several microelements in coal gasification and hydrogenation is established. A geochemical multiplicative indicator is presented which makes quantitative evaluation of the suitability of coals for hydrogenation possible. 17 references.

1984-11-01

273

PSPs at Bhira and Bhivpuri  

International Nuclear Information System (INIS)

Tata Electric Companies (TEC) are engaged in the generation of hydro and thermal energy. TEC, to minimise backing down of its thermal units in off peak hours and also to at least partially meet the growing deficit in the supply during peak hours is moving to install pumped storage plants (PSPs) utilising off-peak surplus energy for pumping the water from lower pond to the upper pond for subsequent utilisation for power generation during peak hours. In view of some of the infra structural facilities such as storage ponds, water conductor system, transmission lines, etc. being already available, at the existing hydro power stations owned by TEC, the pumped storage units are being proposed within the environs of existing hydro stations, i.e. a 150 MW pumped storage unit at Bhira and a 90 MW pumped storage unit at Bhivpuri. The projects are described and cost estimates is given. (author). 2 figs.

1992-01-01

274

Influence of sintering conditions on the #beta#-sialon ceramics properties from power station fly ashes  

International Nuclear Information System (INIS)

Fly ash from Lagisza power station with addition of kaolin and calculated amount of carbon was reacted in flowing nitrogen at 1520"oC in order to obtain #beta#-sialon. The resulted powder was sintered with and without Y_2O_3 addition. Examinations show that it is possible to sinter that material without any sintering additives, however additive of Y_2O_3 decreases sintering temperature of about 100"oC. Sintering temperature influences the final mechanical properties like: flexural strength, microhardness, Young elastic modulus (E) and fracture toughness (K_I_c). (author)

2004-09-12

275

IEEE standard quality assurance program requirements for the design and manufacture of class 1E instrumentation and electric equipment for nuclear power generating station  

International Nuclear Information System (INIS)

The Institute of Electrical and Electronic Engineers (IEEE) standards for the quality assurance requirements for the design and manufacture of Class 1E instrumentation and electric equipment for a nuclear power generating station are presented. This standard establishes Quality Assurance Program requirements for electrical manufacturers. This standard, used in conjunction with ANSI N45.2-1977 and the supplemental standards to the extent referenced in this standard, is intended to meet the requirements of 10CFR50, Appendix B. These requirements are intended to assure that Class 1E instrumentation and electric equipment are responsibly engineered and manufactured from proper materials, that the manufacturing processes and practices are controlled, and that the manufacturing process produces a product of the required quality for Class 1E application.

276

Hybrid insulator - the excellent post insulator for HVAC and HVDC power station  

Energy Technology Data Exchange (ETDEWEB)

A solid layer artificial pollution test was carried out to study the pollution performance of a new type of hybrid station post insulator used in suspension and tensile high voltage transmission lines. The structure of the separated silicone rubber shed and porcelain core hybrid insulator was shown. The new insulator showed excellent pollution performance under both HVAC and HVDC conditions. It also exhibited excellent aging performance in artificial aging tests. The mechanical strength of the hybrid insulator was also better than normal composite insulators. Another advantage revealed was the fact that separated silicone rubber sheds and porcelain core hybrid post insulators are easier to manufacture than normal porcelain post insulators and other hybrid insulators. 5 refs., 6 tabs., 1 fig.

1997-12-31

277

Fingerprint testing of contaminated ventilation extract filter systems at Sizewell B  

International Nuclear Information System (INIS)

Sizewell B is Nuclear Electric's latest power station, and the Pressurised Water Reactor (PWR) design on which it is based represents a ''first'' for the UK. One of the integral components of the plant is the heating, ventilation and air-conditioning (HVAC) system, which performs a contamination control and gaseous waste management function for the site. During the commissioning of Sizewell B Power Station the extract systems of the HVAC plant underwent a procedure known as ''fingerprinting''. This entailed the characterisation of the facilities provided to test the filtration plant during its lifetime. The assessment of their adequacy was then used to identify necessary modifications and/or to propose the manner in which future in situ performance testing would be carried out. The paper outlines the basic principles and procedure that was used to ''fingerprint'' test systems during the commissioning of Sizewell B. A specific example is ...

278

Feeding ecology of mesopelagic zooplankton of the subtropical and subarctic North Pacific Ocean determined with fatty acid biomarkers  

British Library Electronic Table of Contents (United Kingdom)

Mesopelagic zooplankton may meet their nutritional and metabolic requirements in a number of ways including consumption of sinking particles, carnivory, and vertical migration. How these feeding modes change with depth or location, however, is poorly known. We analyzed fatty acid (FA) profiles to characterize zooplankton diet and large particle (>51?m) composition in the mesopelagic zone (base of euphotic zone ?1000m) at two contrasting time-series sites in the subarctic (station K2) and subtropical (station ALOHA) Pacific Ocean. Total FA concentration was 15.5 times higher in zooplankton tissue at K2, largely due to FA storage by seasonal vertical migrators such as Neocalanus and Eucalanus. FA biomarkers specific to herbivory implied a higher plant-derived food sou...

2010-01-01

279

Effect of the tide on the diffusion of "3H in the liquid effluent discharged from Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

The tide field at the time of liquid effluent discharging from Daya Bay nuclear power station, and the average water speed at the monitoring points in west Daya Bay from the time of discharging to the time of sampling were calculated by ADI (Alternating Direction Implicit) method. By comparing analysis, the difference of "3H diffusion between spring tide and neap tide (the expansion of "3H within one day of spring tide is greater than that within one day of neap tide) was found. So, an equivalent diffusion time is introduced to modify the original model, and a better attenuation relation between the average "3He concentration in west Daya Bay and the time since the liquid "3H discharging is obtained. (authors)

2006-07-01

280

Device for transporting loads, especially for belt driving stations in open pit mining  

Science.gov (United States)

A device is described for transporting loads, especially for moving belt driving stations in open pit mining operations with a propelling mechanism which for lifting a respective load is operable to move into a free space formed by the load with the ground. The device comprises a plurality of lifting mechanisms, by means of which, a lifting platform can be brought into engagement with a supporting surface of the load. The device comprises at least one supporting member which is so designed that it prevents the lifting platform from lifting off lifting mechanisms. Furthermore, means are provided which permit a turning of the lifting platform relative to the lifting mechanisms about a vertical axis which is arranged in a certain relationship to the propelling mechanism.

1977-07-19

281

Development of design support system for pipeless batch plants; Pipeless batch plant sekkei shien system no kaihatsu  

Energy Technology Data Exchange (ETDEWEB)

A pipeless batch plant is a batch processing production system using mobile vessels. The plant performances depend on both hardware of equipment and software of operation. So the plant includes many design factors such as number of vessels, stations and AGVS, layout of stations, vessel moving rules, job scheduling and so on. In this paper, the characteristics of pipeless batch plant design are considered to handle the problem by the systems engineering approach. Then, a practical design method known as design-by-analysis is applied to solve such a complex design problem. Based on this concept, a design support system composed of modeling, simulation and evaluation subsystems is developed. This system enables rational decision making through performance evaluation for proposed design of a pipeless batch plant. The usefulness of the system is illustrated by industrial examples. 12 refs., 8 figs., 6 tabs.

1997-07-10

282

Construction progress of the cooling & ventilation in the LHC project  

CERN Document Server

After the LEP dismantling Phase the Cooling and Ventilation Group has started the LHC construction work. Year 2001 through to 2004 will certainly be the most important period of activity for the CV group in the erection phase The author will report on the current works that are in progress on the different LHC Points distinguishing between the Ventilation and the Water Cooling installations. The Ventilation work completed in the new surface buildings in Points 1, 4,5,6 and 8. The work for the Cooling plants comprehend to the pumping stations, the cooling towers and the chilled water production stations in Points 1 and 5, For all of these activities, an updated report of the progress the work, the planning and of the expenses are given. Finally, a brief overview of the future activities is presented.

2002-01-01

283

Construction Progress of the Cooling and Ventilation in the LHC Project  

CERN Document Server

The Cooling and Ventilation Group has started the LHC construction work in September 1999 and will get into full activity when LEP will be stopped and dismantled: in total 12 major contracts for an amount of about 120 MCHF will be established to build the needed installations for the LHC. The author will report on the current works that are in progress on the different LEP Points distinguishing between the Ventilation and the Water Cooling installations. The Ventilation work, completed in the new surface buildings in Points 18, is currently held in Points 4 and 5. Point 1 will follow in the near future. The work for the Cooling plants comprehend the pumping stations, the cooling towers and the chilled water production stations in Points 1 and 5, the buried pipes in Points 1 and 4. For all of these activities, an updated report of the progress of the work, of the planning and of the expenses is given. Finally, a short overview of the future ...

2001-01-01

284

Climatic changes in Central Italy and their potential effects on corn water consumption  

British Library Electronic Table of Contents (United Kingdom)

This study evaluates the trends of meteorological and agrometeorological indices computed at different sites in the Region of Umbria (Central Italy). The indices were selected on the basis of whether they enable the evaluation of the potential effects of climatic changes on agricultural water requirements and management. The meteorological stations were preliminarily selected considering the length and entirety of the data series and a homogeneous spatial coverage of the region under study. The daily rainfall and minimum and maximum temperature data collected at the stations were elaborated to calculate meteorological and agrometeorological indices (for corn, widespread irrigated crop in Central Italy).The results of the analysis show that rainfall has decreased generally everywhere and th...

2008-01-01

285

An integrated oil and chemicals chain  

International Nuclear Information System (INIS)

Last year, 1991, was a difficult one for Finland's oil and chemicals company, Neste Corporation. The sharp fall in the international price of chemicals products had a significant impact on the corporation's overall result. Neste was, however, able to improve its competitive position, move ahead with numerous investments, and develop new businesses. This was particularly evident in two areas that have received significant emphasis within Neste in recent years: oil exploration and the Baltic region where a network of modern service stations in Neste livery and stretching from Vyborg on the Finnish-Russian border, through St. Petersburg, Tallinn, and the Baltic countries to Warsaw, is currently taking shape. The majority of the western-style stations in this network will be located along the route of the M12 highway, which has been dubbed the Via Baltica.

286

Alteration in reactor installation (addition of Unit 2) in the Sendai Nuclear Power Station of Kyushu Electric Power Co., Inc  

International Nuclear Information System (INIS)

The deliveration by the Nuclear Safety Commission was commenced on the alteration in reactor installation, as it had been inquired by the Ministry of International Trade and Industry. The alteration is the additional installation of the reactor No. 2 in the Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc. It is a PWR power plant with thermal output of about 2,660 MW (electric output of 890 MW), to be installed, adjoining to the reactor No. 1 of the same type and capacity under construction. In the examination by MITI, it was confirmed that the technological capabilities for its construction and operation and the radiation protection measures in power generation are both sufficient. The contents of the examination include the siting conditions, the location and construction of reactor facilities, etc. (J.P.N.).

1980-01-01

287

Alteration in reactor installation (addition of Unit 2) in the Sendai Nuclear Power Station of Kyushu Electric Power Co. , Inc  

Energy Technology Data Exchange (ETDEWEB)

The deliberation by the Nuclear Safety Commission was initiated on the alteration in reactor installation, as was required by the Ministry of International Trade and Industry. The alteration is the additional installation of the reactor No. 2 in the Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc. It is a PWR power plant with thermal output of about 2,660 MW (electric output of 890 MW), to be installed, adjoining to the reactor No. 1 of the same type and capacity under construction. In the examination by MITI, it was confirmed that the technological capabilities for its construction and operation and the radiation protection measures in power generation are both sufficient. The contents of the examination include the siting conditions, the location and construction of reactor facilities, etc.

1980-10-01

288

Ageing and life-time management in nuclear power stations - concept and examples; Alterungs- und Lebensdauermanagement in Kernkraftwerken - Konzept und Beispiele  

Energy Technology Data Exchange (ETDEWEB)

Knowledge, assessment and understanding of phenomena caused by ageing, together with systematic utilization and extension of the technical life-time of components and systems, are of critical importance to the safety and economy of electricity generation in nuclear power stations. Economic use can be optimized by integrated ageing and life-time management; it can also be used to improve performance characteristics. (orig.) [Deutsch] Fuer die Sicherheit und Wirtschaftlichkeit der Stromerzeugung in Kernkraftwerken sind die Kenntnis, Bewertung und Beherrschung alterungsbedingter Phaenomene und systematische Ausnutzung bzw. Verlaengerung der technischen Lebensdauer der Komponenten und Systeme von zentraler Bedeutung. Durch ganzheitliches Alterungs- und Lebensdauermanagement, das auch auf die Verbesserung von Leistungsmerkmalen abzielt, kann der wirtschaftliche Nutzen optimiert werden. (orig.)

1999-07-01

289

Adenopathies in lung cancer: a comparison of pathology, Computed Tomography and endoscopic ultrasound findings  

International Nuclear Information System (INIS)

A prospective comparative study with pathology was performed to assess the clinical value of Computed Tomography (CT) and endoscopic ultrasound (EUS) for nodal staging in lung cancer. A total of 329 nodal stations were dissected or sampled and 755 lymph nodes were examined at histology. On a pre-station basis, CT had greater sensitivity (74%) than EUS (56%), but EUS was more specific (83% versus 93%). The accuracy rates of the two techniques were similar. In conclusion, endoscopic ultrasound should be part of a routine preoperative diagnostic approach to non-small-cell lung cancer., because of its high specificity. Results can be improved when EUS and CT are combined., which suggests that these imaging modalities should be used together in selected patients for the noninvasive staging of non-small-cell lung cancer to identify local lymphatic spread.

1999-01-01

290

"2"2"2Rn as indicator of atmospheric turbulence: measurements at Lake Maggiore and on the pre-Alps  

International Nuclear Information System (INIS)

Radon concentration measurements in atmosphere were taken in years from 1997 to 1999 in Milan and at pre-alpine sites located north of Lombardy. In this paper the results of measuring campaigns and a comparison of radon levels observed in the hilly area north of the town and on the pre-Alps are reported. The general criteria of the measurements and the interpretative models of radon concentration are presented. The Lake Maggiore area shows evidence of a great nocturnal stability and frequent formation of Nocturnal Stable Layer. The peculiar findings in the high altitude stations confirm the use of radon as an indicator of atmospheric dispersion of pollutants in an area with complex orography. The afternoon minimum values are concordant for the different stations: this implies a remixing in afternoon hours over the whole area investigated.

291

Wolsung-1 nuclear power plant  

International Nuclear Information System (INIS)

The Wolsung-1 CANDU 600 MWe plant is now in operation. This paper provides an update on the design, construction and commissioning progress reported at last year's conference. The accomplishments of the past year are highlighted with emphasis on how the station has been commissioned in preparation for commercial service and on the skills that were dedicated to the completion of the project. The paper also deals with some of the features of the CANDU 600 MWe Nuclear Power Plant that make it viable for export.

1977-06-05

292

Use of the acoustic method for checking the quality of concrete of hydroelectric and pumped storage stations  

Energy Technology Data Exchange (ETDEWEB)

This article describes acoustic methods used in the in-service inspection of the dams and peripheral concrete structures of the Toktogul, Kurpsai, and Bratsk hydroelectric and pumped storage plants. The tests were conducted to assess the compression strength, elasticity, and tensile strength of the concretes. Comparative evaluations against drill core studies proved the acoustic methods to be sufficiently accurate in predicting aging behavior and loss of mechanical and physical integrity in the concretes.

1987-09-01

293

Themis solar receiver  

Energy Technology Data Exchange (ETDEWEB)

The conception of a solar receiver intended to equip a tower power-station has to combine multiple requirements: very highly concentrated solar flux, unsteady in time and space; necessity to obtain a high efficiency; respect of the physical limits of the materials and of the fluid. The description of Themis solar receiver and of its operation is preceded by considerations which have led to the choice of the cavity, of the fluid and of its circulation.

1982-01-01

294

Thailand: utilisation programme set for massive expansion  

Energy Technology Data Exchange (ETDEWEB)

The US$360 million project to increase gas supplies to Eastern and Southern Thailand is discussed, and the use of international competitive bidding to purchase the line pipe and other facilities is reported. The government approved proposal for a gas fired combined-cycle power station and gas separation plant are discussed. (UK).

1991-11-01

295

Supervision monitoring for radiation environment around Daya Bay and Lingao nuclear power stations  

International Nuclear Information System (INIS)

This paper systematically introduces the supervision monitoring for radiation environment around the Guangdong Daya Bay and Ling Ao nuclear power station by the Guangdong Environmental Radiation Research and Monitoring Center. It includes the monitoring plan, methods, quality assurance, main results and conclusions. The results show that: (1) The gas discharge have not caused any detectable impacts to the terrestrial and atmospheric environment since their operation; (2) "1"1"0"mAg could only be detected in seawater in the West Daya Bay in 1995 and 1997 and in sediments in 1997. The maximum annual average in seawater was 3.1 Bq/m"3, annual average of "1"1"0"mAg in sediments was 1.0 Bq/kg(dry). But it was always detectable in pearl oyster, gulfweed and cuttlefish in the West Daya Bay. The "1"1"0"mAg concentrations in halobios were relatively higher in 1994, 1996 and 1997. The maximum concentrations in pearl oyster, gulfweed and cuttlefish were 2.2, 1.7 and 5.8 Bq/kg ...

2004-05-01

296

Study of Water Quality Value in Sub of the Stream Area of Cisadane Rivers Upstream as Reference Area Based on Macro invertebrate Composition  

International Nuclear Information System (INIS)

Specific structure of biota community condition can used as indicator for the ecosystem stability value or the waters pollution level where the aquatic biota exist. the macro invertebrates as bio indicator organism can used to assess the upper Cisadane Sub River Basin water quality. The grouping and calculation result from family number, Ept presences (sensitive macro invertebrate), Diversity index (H"'), DO value and TOC value showed 5 criteria of water quality as reference site. This criteria is used to determine water quality level from ten branches of rivers in the upper Cisadane Sub River Basin, Cijeruk districts. The biotic index calculation for ASPT (Average Score Per Taxon) and T and T (index Trihadiningrum and Tjindronegoro) is used to asses water quality based on macro invertebrate composition indicator. Both biotic index system support and give the similar evaluation to water quality level from ten branches of river on the upper Cisadane Sub River Basin. The water quality ...

2001-11-01

297

Steam generator tube failures: experience with water-cooled nuclear power reactors during 1976  

International Nuclear Information System (INIS)

A survey was conducted of experience with steam generator tubes at nuclear power stations during 1976. Failures were reported at 25 out of 68 water-cooled reactors. The causes of these failures and the repair and inspection procedures designed to cope with them are summarized. Examination of the data indicates that corrosion was the major cause of steam generator tube failures. Improvements are needed in steam generator design, condenser integrity and secondary water chemistry control. (author).

1994-10-18

298

Shuttle Showcase: STS-124  

National Aeronautics and Space Administration (NASA)

The second in a series of flights to assemble the Japanese segment of the International Space Station saw the mammoth Kibo module delivered to the complex complements of Discovery and its crew on the STS-124 mission. Kibo, the Japanese word for u201chopeu201d would house dozens of experiments and serve as a platform for external payloads brought to the complex on subsequent Shuttle flights and the Japanese u201cKounotoriu201d H-2 Transfer Vehicle cargo ship.

2011-07-10

299

Robotics: Growing maintenance option for utilities  

International Nuclear Information System (INIS)

The use of robots in powerplants is an option that can no longer be ignored. Robots can reduce worker exposure to harmful environments and minimize downtime. As a result, electric utilities are using them more than ever. As robots become more widely accepted, more are being developed to handle an expanding variety of applications. This report begins with an overview of the use of robotics in the electric-utility industry; following that are sections detailing applications for nuclear plants, fossil-fired stations, and transmission and distribution facilities.

300

Proceedings of the 1988 IEEE international conference on robotics and automation. Volume 1  

International Nuclear Information System (INIS)

These proceedings compile the papers presented at the international conference (1988) sponsored by IEEE Council on ''Robotics and Automation''. The subjects discussed were: automation and robots of nuclear power stations; algorithms of multiprocessors; parallel processing and computer architecture; and U.S. DOE research programs on nuclear power plants.

1988-04-24

301

Principles of ground relaying for high voltage and extra high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

This paper is a tutorial discussion of the basic principles of ground relaying for high voltage and extra high voltage transmission lines. Three different HV configurations are considered: Long lines, lines with a weak mid-point station, and mutually-coupled lines. Application criteria for EHV circuits are also discussed, and specific setting calculations are included where appropriate.

1983-02-01

302

Plant for processing sewage gas to natural-gas quality  

Energy Technology Data Exchange (ETDEWEB)

Sewage gas or biogas as a product of anaerobic digestion contains methane and carbon dioxide as its main components. Biogas is scrubbed off carbon dioxide in absorption columns and purified to natural-gas quality. The purified gas then is piped to the gas pressure control station and fed into the public network. Description of process and plant is given.

1983-09-01

303

On protecting steel pile foundations of oil field structures from corrosion  

Energy Technology Data Exchange (ETDEWEB)

In the area of seasonally thawing soil, porous or broken coatings cannot significantly retard the process of pile metal destruction, since it will occur through electroosmotic penetration of the base electrolyte to the metal surface. Such processes can be prevented by electrochemical protective methods. Systems based on grid cathode stations with power control and distribution units are recommended for use for cathode protection of steel pile foundations.

1980-01-01

304

Occupational exposure information system in Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

This paper introduces an occupational exposure information system in detail, which is developed and in operation presently by Daya Bay nuclear power plant. It is presented in the paper that individual dose monitoring items and method, design and classification of database configuration, statistics and analysis of individual dose, and management of staff entering and exiting controlled area. The system is instructive to analysing individual dose and optimizing radiation protection measures. (authors)

2005-07-01

305

NAME=\\  

Wastenet

... The structure comprises piled foundations supporting a steel frame, and is clad in both masonry and rainscreen cladding systems. The hotel is adjacent to the recently redeveloped bus station in the centre of Norwich. Related Services Structural Design Go View all Services Find Projects Sector All Sectors Buildings & Infrastructure Environment Natural Resources Transportation Sub Sector All Sub-Sectors Country All Countries Angola Antigua and Barbuda Argentina ...

306

Monitoring, sampling and analysis of fine particulates -- Results and experiences from DOE's Federal Energy Technology Center  

Energy Technology Data Exchange (ETDEWEB)

The overall goal of the DOE fine particulate program is to ensure that the best science and technology is available for any regulatory decision-making related to the health and environmental impacts of ambient fine particulate matter and regional haze. Interest primarily lies in the particulate fraction having aerodynamic diameters of 2.5 microns and less (PM2.5). Particulates of this size are the focus of the newly established National Ambient Air Quality Standards. As such, the Federal Energy Technology Center (FETC) is establishing a fine particulate sampling station at the Center's Pittsburgh site located in South Park Township, PA. This sampling station is one of a group of stations scattered throughout Pennsylvania, West Virginia, and Ohio that constitute the Upper Ohio River Valley Project. The station is equipped with a full complement of fine particulate and gaseous monitors including ...

1999-07-01

307

Modernization of high pressure steam turbines and low pressure steam turbines in the coal-fired power plant Bergkamen; Modernisierung der Hoch- und Niederdruckdampfturbinen im Kohlekraftwerk Bergkamen  

Energy Technology Data Exchange (ETDEWEB)

In the year 2008, the high pressure partial turbine and two low pressure partial turbines in the hard coal power station Bergkamen (Federal Republic of Germany) were modernized. A three-dimensional blade design and innovative seals were used. This resulted into a distinct increase in efficiency among other things.

2010-07-01

308

Improvements in SISCOM II technology; Introduccion de Mejoras Tecnologicas en el SISCOM II  

Energy Technology Data Exchange (ETDEWEB)

This document is the Final Report for the project Introduccion de Mejoras Tecnologicas en el SISCOM II, or Improvements in SISCOM II Technology. It consists of a brief description of the activities carried out during the project, and several Annexes that explain in a deeper way each result. SISCOM II is the main telemetry system currently in use in the Spanish underground coal mining, but it was developed ten years ago and needed a technological update, which was the objective of this project. The aims of the project were: To develop Hardware and Software for the Out stations currently used (maintenance developments) To design new hardware and software, easier to use in the current and new applications of SISCOM II Both objectives were met, although not in the way originally intended. The main results were: In the field of old Out stations update: A new set of boards for the old Out stations was developed Out ...

2000-07-01

309

Human error and experienced feedback during refuelling overhauling of Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

The authors describe the various human error encountered during Daya bay refueling overhaul, and the subsequent root cause evaluation and protective measure. Authors consider transparency is the key in reducing human error and event recurrence. Additional y, event transparency will enhance the effectiveness if experience feedback and reduce event consequence

2000-10-01

310

Grid-Search Location Methods for Ground-Truth Collection From Local and Regional Seismic Networks  

Energy Technology Data Exchange (ETDEWEB)

This project investigated new techniques for improving seismic event locations derived from regional and local networks. The technqiues include a new approach to empirical travel-time calibration that simultaneously fits data from multiple stations and events, using a generalization of the kriging method, and predicts travel-time corrections for arbitrary event-station paths. We combined this calibration approach with grid-search event location to produce a prototype new multiple-event location method that allows the use of spatially well-distributed events and takes into account correlations between the travel-time corrections from proximate event-station paths. Preliminary tests with a high quality data set from Nevada Test Site explosions indicated that our new calibration/location method offers improvement over the conventional multiple-event location methods now in common use, and is applicable to more general ...

2005-05-13

311

Foshan. A fast track combined cycle for Guangdong  

Energy Technology Data Exchange (ETDEWEB)

To meet growth in the fast developing Pearl River Delta economic zone in China`s Guangdong province, a 270 MW oil-fired combined cycle at Foshan was built and commissioned in only 22 months from financial closure. This article describes the Foshan power station, specifications, design, procurement, construction and operating concerns. 5 figs.

1995-03-01

312

Evaluation of technology modifications required to apply clean coal technologies in Russian utilities. Final report  

Energy Technology Data Exchange (ETDEWEB)

The report describes the following: overview of the Russian power industry; electric power equipment of Russia; power industry development forecast for Russia; clean coal technology demonstration program of the US Department of Energy; reduction of coal TPS (thermal power station) environmental impacts in Russia; and base options of advanced coal thermal power plants. Terms of the application of clean coal technology at Russian TPS are discussed in the Conclusions.

1995-12-01

313

Electricity supply in the United Kingdom. Brief details and statistics  

Energy Technology Data Exchange (ETDEWEB)

Statistical detail is given of the electricity generation and transmission systems in the UK. Breakdown by type of station, by fuel and the proportion generated by others apart from the generating or area boards is presented. Figures are provided for the various high voltage transmission lines in terms of route and circuit length as well as the number of towers and the capacity of mains transformers.

1987-06-01

314

ECONOMICS OF RETROFITTING BIG RIVERS ELECTRIC CORPORATION'S LIME-BASED FGD (FLUE GAS DESULFURIZATION) SYSTEM TO ORGANIC-ACID-ENHANCED LIMESTONE OPERATIONS  

Science.gov (United States)

The report describes the site specific changes required to convert an existing lime FGD system to a limestone system enhanced by dibasic acid (DBA) or adipic acid, and the costs of making such a change. In 1982-83, pilot plant tests were conducted at the R. D. Green Station of Bi...

315

Development and evaluation for passive dosimeter using several solid dosimeters  

International Nuclear Information System (INIS)

Passive dosimeters for personal and area radiation monitor in space have been developed mainly for dosimetry in low-earth-orbit (LEO) radiation environments of Space Shuttles and the International Space Station. The responses of several dosimeters have been evaluated by heavy ions and also its variation for individual dosimeter element. (author)

2005-05-01

316

Cooling of nuclear power stations with high temperature reactors and helium turbine cycles  

International Nuclear Information System (INIS)

On nuclear power stations with high temperature reactors and helium turbine cycles (HTR-single circuits) the residual heat from the energy conversion process in the primary and intermediate coolers is removed from cycled gas, helium. Water, which is circulated for safety reasons through a closed circuit, is used for cooling. The primary and intermediate coolers as well as other cooling equipment of the power plant are installed within the reactor building. The heat from the helium turbine cycle is removed to the environment most effectively by natural draught cooling towers. In this way a net plant efficiency of about 40% is attainable. The low quantities of residual heat thereby produced and the high (in comparison with power stations with steam turbine cycles) cooling agent pressure and cooling water reheat pressure in the circulating coolers enable an economically favourable design of the overall 'cold end' to be expected. In the so-called ...

317

Condenser replacement at Unterweser nuclear power station  

International Nuclear Information System (INIS)

In spite of extensive cooling water studies premature damage due to corrosion occurred on the CuZn20Al condenser tubes. It was then decided to incorporate new titanium-tubed condensers during the annual overhauls of 1983 and 1985 and also take ameliorating measures up to the exchange of individual condensers. (orig.).

318

Chalk Point Cooling Tower Project: Cooling Tower Effects on Crops and Soils. Preoperational Report, Appendix.  

Science.gov (United States)

This report contains data collected on a monthly basis over the period April, 1973 - April, 1975 for dustfall particulates, sodium and chloride and SO2 levels obtained from 12 monitoring sites near the Chalk Point Generating Station operated by PEPCO and ...

1976-01-01

319

Chalk Point Cooling Tower Project: Cooling Tower Effects on Crops and Soils. Post Operational Report No. 2.  

Science.gov (United States)

This report contains a summary of monthly dustfall, SO2, rainfall, crops and soils information obtained over the period May, 1976 to March, 1977 from 12 monitoring sites near the Chalk Point Generating Station operated by PEPCO which is located 65 km sout...

1977-01-01

320

Chalk Point Cooling Tower Project. Volume 2. Cooling Tower Drift Dye Tracer Experiment, June 16 and 17, 1977.  

Science.gov (United States)

A drift dye tracer experiment, using Rhodamine (WT) dye, was conducted on airborne drift from a natural draft cooling tower at PEPCO's Chalk Point, Maryland Power Generating Station. This experiment was designed to separate and identify cooling tower aero...

1977-01-01

321

Atoms at work  

International Nuclear Information System (INIS)

This illustrated booklet describes the fission process; the use of uranium to produce power in nuclear power stations (and a brief explanation of the differences between the principal types of reactor); the formation of plutonium and fission products; radioactive wastes and their management; nuclear fusion and a conceptual fusion reactor; alpha, beta and gamma radiations; radioisotopes and their applications. (U.K.).

322

Application of remote sensing for coal waste embankment monitoring  

Energy Technology Data Exchange (ETDEWEB)

The Bureau of Mines has two projects in the remote sensing field as it pertains to mining. One of these is a completed contract that studied the use of aircraft mounted cameras and the results of photogrammetry. The second project is an ongoing contract to study the effectiveness of using an instrumentation system wired to remote data collection station to record embankment data. 6 refs.

1981-01-01

323

Applicability of an exposure model for the determination of emissions from mobile phone base stations  

DEFF Research Database (Denmark)

Applicability of a model to estimate radiofrequency electromagnetic field (RF-EMF) strength in households from mobile phone base stations was evaluated with technical data of mobile phone base stations available from the German Net Agency, and dosimetric measurements, performed in an epidemiological study. Estimated exposure and exposure measured with dosemeters in 1322 participating households were compared. For that purpose, the upper 10th percentiles of both outcomes were defined as the 'higher exposed' groups. To assess the agreement of the defined 'higher' exposed groups, kappa coefficient, sensitivity and specificity were calculated. The present results show only a weak agreement of calculations and measurements (kappa values between -0.03 and 0.28, sensitivity between 7.1 and 34.6). Only in some of the sub-analyses, a higher agreement was found, e.g. when measured instead of interpolated geo-coordinates were used to calculate the ...

2008-01-01

324

Advancements in electric and hybrid electric vehicle technology  

Energy Technology Data Exchange (ETDEWEB)

Contents of this volume include: Influence of Battery Characteristics on Traction Drive Performance; Chassis Design for a Small Electric City Car; Thermal Comfort of Electric Vehicles; Power Quality Problems at Electric Vehicle`s Charging Station; The Development and Performance of the AMPhibian Hybrid Electric Vehicle; The Selection of Lead-Acid Batteries for Use in Hybrid Electric Vehicles; and more.

1994-12-31

325

A computer program for estimating decommissioning costs for light water reactors  

Energy Technology Data Exchange (ETDEWEB)

This report discusses a desk-top computer program has been developed for estimating the costs, waste volumes, and occupational radiation exposures associated with decommissioning light-water reactor power stations. Cost categories and cost algorithms used in the program are discussed and a brief description of the user interface is given.

1993-02-01

326

18-months cycle reload design verifications of Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

18-Months cycle reload design verifications of Daya Bay NPS is briefly described. It was attempted giving the description of analysis scope and key technology for a nuclear power plant which will be changed fuel management strategy from one year to 18-months cycle

2002-10-01

327

Detection of high-frequency radiation sources during the 2004 Parkfield earthquake by a matched filter analysis  

Science.gov (United States)

Introduction Uchide and Ide [SSA Spring Meeting, 2009] proposed a new framework for studying the scaling and overall nature of earthquake rupture growth in terms of cumulative moment functions. For better understanding of rupture growth processes, spatiotemporally local processes are also important. The nature of high-frequency (HF) radiation has been investigated for some time, but its role in the earthquake rupture process is still unclear. A wavelet analysis reveals that the HF radiation (e.g., 4 - 32 Hz) of the 2004 Parkfield earthquake is peaky, which implies that the sources of the HF radiation are isolated in space and time. We experiment with applying a matched filter analysis using small template events occurring near the target event rupture area to test whether it can reveal the HF radiation sources for a regular large earthquake. Method We design a matched filter for multiple components and stations. Shelly et al. [2007] attempted identifying ...

2009-12-01

328

Statistical description and estimation of ocean drift ice environments  

Energy Technology Data Exchange (ETDEWEB)

Part I of this thesis is on long-term iceberg collision-risk assessment methods for fixed offshore structures. Estimates for the long-term probability that an iceberg will hit a fixed offshore structure are based on estimates of the total volume of produced iceberg, a model for the size distribution of icebergs and a description of how iceberg trajectories ``fill`` the plane (the ocean`s surface). Part II of the thesis discusses methods for analysis of low resolution data in the sense that the size of the area covered by each pixel is not small compared to the dominating floes. Still, this type of data can provide estimates of the ice extent (and hence the ice edge) and ice concentration. The estimates of the ice edge (at least) seem to be physically significant in the sense that ``in some way`` they can reflect ice drift in an image time sequence. A priori this is far from obvious. A central idea is that the ``ice edge`` is close to a transition zone between two different temperature ...

1991-04-01

329

Reference scenarios for deforestation and forest degradation in support of REDD: a review of data and methods  

Energy Technology Data Exchange (ETDEWEB)

Global climate policy initiatives are now being proposed to compensate tropical forest nations for reducing carbon emissions from deforestation and forest degradation (REDD). These proposals have the potential to include developing countries more actively in international greenhouse gas mitigation and to address a substantial share of the world's emissions which come from tropical deforestation. For such a policy to be viable it must have a credible benchmark against which emissions reduction can be calculated. This benchmark, sometimes termed a baseline or reference emissions scenario, can be based directly on historical emissions or can use historical emissions as input for business as usual projections. Here, we review existing data and methods that could be used to measure historical deforestation and forest degradation reference scenarios including FAO (Food and Agricultural Organization of the United Nations) national statistics and various remote sensing sources. The ...

2008-04-15

330

Reference scenarios for deforestation and forest degradation in support of REDD: a review of data and methods  

International Nuclear Information System (INIS)

Global climate policy initiatives are now being proposed to compensate tropical forest nations for reducing carbon emissions from deforestation and forest degradation (REDD). These proposals have the potential to include developing countries more actively in international greenhouse gas mitigation and to address a substantial share of the world's emissions which come from tropical deforestation. For such a policy to be viable it must have a credible benchmark against which emissions reduction can be calculated. This benchmark, sometimes termed a baseline or reference emissions scenario, can be based directly on historical emissions or can use historical emissions as input for business as usual projections. Here, we review existing data and methods that could be used to measure historical deforestation and forest degradation reference scenarios including FAO (Food and Agricultural Organization of the United Nations) national statistics and various remote sensing sources. The freely ...

331

Comparison and validation of two high-resolution weather forecast models at Frankfurt Airport  

Energy Technology Data Exchange (ETDEWEB)

In recent years the 'Nowcasting Wake Vortex Impact Variables' model NOWVIV has been developed at the Deutsches Zentrum fuer Luft- und Raumfahrt, DLR, to forecast weather parameters in airport environments. The German Meteorological Service, DWD, employs his COSMO-DE model (COnsortium for Small scale Modelling-DEutschland) for operational forecasts in Germany. A systematic comparison of model output from NOWVIV and a derivate of COSMO-DE, named COSMO-FRA, is presented. Both models are centred at Frankfurt Airport with horizontal resolutions of 2.1 km and 2.8 km, respectively. In the DLR Project Wetter and Fliegen the COSMO-FRA model will replace the NOWVIV model and become a key component in the future rapid update cycle for adverse weather predictions at the airports of Frankfurt and Munich. The forecast vertical profiles of runway crosswind, head/tail wind, temperature, and turbulent kinetic energy (TKE) are validated against Wind and Temperature ...

2009-10-15

332

Thermal analysis of spent fuel in shuttle station during dry transfer under abnormal cooling conditions for TAPS - 4  

International Nuclear Information System (INIS)

A pair of bundles is placed in a shuttle tube, which is enclosed by a carriage tube kept inside the Shuttle Transfer Station (STS). It takes about 90 minutes for the spent fuel bundles to travel from the reactor channel to Transfer Magazine (TM). Subsequently, the dry transfer operation takes about 4 minutes. An emergency air cooling flow rate of 600 m3/hr is supplied to cool the spent fuel bundles after they reach the STS, following lapse of 4 minutes of spent fuel dry transfer, in case the bundles are not submerged in the light water in STS. A thermal and hydraulic safety analysis has been done to estimate the maximum sheath temperature, if the spent fuel bundles are stuck at a location of 30 mm below the normal location aligned to the TM port. This position of the spent fuel will have least cooling from the emergency cooling airflow. At the same time, the shuttle tube carrying the spent fuel bundle is just above the water. From the analysis it has been concluded ...

2006-11-13

333

Solid radioactive waste management in Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

This paper introduces the solid radwaste management system, treatment methods and its continuous improvement during the past 9 years in Guangdong Daya Bay Nuclear Power Station (GNPS). GNPS has paid great attention and made a lot of efforts to implement the principle of waste minimization with source control, improvement of treatment process and strict management, so the output of solid radwastes has annually decreased since 1994. In 2002, the output of solid radwastes in GNPS was 63.5 m"3, only 50% of 1995 (127 m"3), reached the advanced level as the same type NPPs in France. During the period 1994-2002, the accumulated production of solid radwaste Packages in GNPS is 1563.51 m"3 only 18% of the design value; all the packages meet the standard and requirement for safe disposal. Besides, this paper analyzes some new technical processes and presents some proposals for further decreasing the solid radwaste production

2004-05-01

334

Simulator training and licensing examination for nuclear power station operator  

International Nuclear Information System (INIS)

For the recruitment, training and position qualification of the simulator instructors and feedback of training effect, the management approaches are formulated in 'The System for Simulator Training and Licensing Examination of Daya Bay Nuclear Power Station Operators'. The concrete requirements on the professional knowledge, work experience and foreign language ability of a simulator instructor are put forward. The process of instructor training is designed. The training items include the trainer training, pedagogy training, time management training, operation activities training during outage of unit, 'shadow' training and on-the-jot training on simulator courses. Job rotation is realized between simulator instructor and licensing personnel on site. New simulator instructor must pass the qualification identification. After a duration of 2 years, re-qualification has to be carried out. On the basis of the operator training method introduced from EDF (electricite De ...

2007-08-01

335

Results of third regular inspection of No. 2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co. , Inc  

Energy Technology Data Exchange (ETDEWEB)

The third regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from December 27, 1988 to May 25, 1989. The parallel operation was resumed on April 28, 1989, 123 days after the parallel off. The facilities which were the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation and emergency electric power generation system. On the facilities which were the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out. As the results, significant in indication was observed in 8 bolts for fixing the flow-changing vanes of primary coolant pumps, and broken valve spindles were found, but other abnormality was not found. The works related to this regular inspection were accomplished within the range of the limit of radiation dose equivalent based ...

1990-03-01

336

Results of second regular inspection of No.2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc  

International Nuclear Information System (INIS)

The second regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from October 5, 1987 to January 8, 1988. the parallel operation was resumed on December 8, 1987, 65 days after the parallel off. The facilities as the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation, and emergency power generation system. On these facilities as the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out, and abnormality was not found at all. The works related to this regular inspection were accomplished within the range of allowable dose based on the relevant laws. The main reconstruction works carried out during the period of this regular inspection were the change of the degree of enrichment from 3.15 wt.% to 3.4 wt.% for replacement fuel so as ...

1988-01-01

337

Results of second regular inspection of No. 2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co. , Inc  

Energy Technology Data Exchange (ETDEWEB)

The second regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from October 5, 1987 to January 8, 1988. the parallel operation was resumed on December 8, 1987, 65 days after the parallel off. The facilities as the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation, and emergency power generation system. On these facilities as the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out, and abnormality was not found at all. The works related to this regular inspection were accomplished within the range of allowable dose based on the relevant laws. The main reconstruction works carried out during the period of this regular inspection were the change of the degree of enrichment from 3.15 wt.% to 3.4 wt.% for replacement fuel so as ...

1988-08-01

338

Research and implementation of stretch-out operation in Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

Stretch-out operation mode can deepen the reactor burnup when the boron concentration is near 0 mg/L, in which the additional reactivity is introduced by the reducing of the moderator temperature and the decreasing of the load. Stretch-out is used in many nuclear power plants all over the world. The first stretch-out operation has been used for the first time in China. As a specific operation mode, which outruns the original reactor core design, the related and specialized design argument and safety analysis is required. As a consequence of the continuous or stepwise reduction of load and moderator temperature, the neurotic measurement system and the reactor control and protection system parameters should be modified specially. Based on the schedule of the electricity production, the first stretch-out operation had been carried out from March 12 to March 21 2003. It successfully avoided the overlapping between 209 and 109 inspection shutdowns in Daya Bay Nuclear power ...

2006-02-01

339

Repair of failed 138kV pipe type cable line  

Energy Technology Data Exchange (ETDEWEB)

On February 9, 1995 ComEd experienced a pipe type cable failure on 138kV line 13717. Line 1737 is a bulk power transmission cable circuit connecting The Fisk and Crawford generating stations located within city limits. The line is approximately 4.5 miles long and was originally installed in 1975. This line is forced cooled, has 2,500 KCMIL copper conductors with 505 mils of paper insulation in an 8 inch pritec coated steel pipe. The splices are constructed with Voltalit castings. The failure occurred approximately 3,500 feet from Crawford Station. It was easy to locate the failure since the cable joint casing was breached resulting in the loss of approximately 2,600--2,700 gallons of dielectric fluid. Upon field examination B Phase was determined to have failed. The failure occurred 12 inches inside the casing in an area where it was impossible to install a long connector or add an additional short length of cable to create a piece out. The ...

1996-11-01

340

Relationships between cosmic ray neutron flux and rain flows  

International Nuclear Information System (INIS)

The registration of secondary cosmic ray neutrons is a convenient tool for the investigation of primary cosmic ray variations and for meteorological effects as well. At present a large network of neutron monitors exists, aiming at studies of cosmic ray variations which are related to interplanetary conditions and geomagnetic activity. At the same time cosmic ray variations may be related to some atmospheric processes. In this connection, using the data from two neutron monitors (a standard and a lead free one), a gamma detector from Moscow station and lead free neutron monitor at BEO Moussala, we studied the correlations between rain flows and neutron flux. In this study we used daily averages on the basis of 10 min data for the neutron flux, corrected for barometric pressure and data from local meteo-stations. The preliminary analysis indicates a correlation between rain flows and neutron flux in several cases. To explain observable ...

2008-09-01

341

Reducing the costs of ultrapure water production - a case study  

Energy Technology Data Exchange (ETDEWEB)

The 380 MW combined cycle gas turbine power station in Peterborough changed its water supply from town mains to high purity reverse osmosis permeate in October 2000. The high purity water is produced from secondary treated sewage effluent using advanced membrane technology. Alpheus Environmental and British Gas staff have recently completed a study of the power station's demineralization plant to identify the differences in operating costs associated with the change in feedwater. The results show that the ultrapure water produced after the change to a high purity feed is of improved quality and that the demineralization plant regeneration operating costs have been reduced by over 90%. The demineralization plant availability has increased from 78 to 98% enabling almost 20% more ultra pure water to be produced. The change in feedwater has also improved the local environment by significantly reducing the amount of waste chemicals ...

2002-02-01

342

Local and regional ozone production: Chemistry and transport  

International Nuclear Information System (INIS)

The EUROTRAC sub-project ''Tropospheric Ozone Research'' (TOR) follows a dual strategy: - Observation of the chemical processes contributing to the oxygen balance directly in the atmosphere; - Establishment of a validated data base for model calculations. Both tasks require simultaneous measurements of a wide range of chemical and meteorological components. In the case of the investigation of the chemical processes, it is also desirable to measure the free radicals directly involved in ozone production. In the project described, a measuring station was set up. For a period of two years and a half, continuous measurements were made of ozone and its chemical precursors (NO, NO_2, NO_y, VOC, CO), as well as other photooxidants (H_2O_2 and organic hydroperoxides, organic nitrates), the photolysis frequency of NO_2, and meteorological parameters (wind, temperature, moisture, aerosols). The station was located on the Schauinsland mountain in the ...

343

Leak-before-break strategy for CANDU primary piping systems  

Energy Technology Data Exchange (ETDEWEB)

Recent advances in elastic-plastic fracture mechanics have made it possible to assess the stability of cracks in ductile piping systems. These technological developments have been used by Ontario Hydro as the nucleus of an approach for demonstrating that CANDU primary heat transport piping systems will not break catastrophically; at worst they would leak at a detectable rate. This leak-before-break approach has been taken on the Darlington nuclear generating station as a design stage alternative to the provision of pipe whip restraints on large diameter, primary heat transport system piping. Positive conclusions reached via this approach are considered sufficient to exclude the requirement to provide protective devices, such as pipe whip restraints. In arriving at the proposed leak-before-break approach a review of current and proposed leak-before-break licensing positions of other jurisdictions (particularly those in the United States and the Federal Republic of ...

1986-01-01

344

Joint Uplink and Downlink Relay Selection in Cooperative Cellular Networks  

CERN Document Server

We consider relay selection technique in a cooperative cellular network where user terminals act as mobile relays to help the communications between base station (BS) and mobile station (MS). A novel relay selection scheme, called Joint Uplink and Downlink Relay Selection (JUDRS), is proposed in this paper. Specifically, we generalize JUDRS in two key aspects: (i) relay is selected jointly for uplink and downlink, so that the relay selection overhead can be reduced, and (ii) we consider to minimize the weighted total energy consumption of MS, relay and BS by taking into account channel quality and traffic load condition of uplink and downlink. Information theoretic analysis of the diversity-multiplexing tradeoff demonstrates that the proposed scheme achieves full spatial diversity in the quantity of cooperating terminals in this network. And numerical results are provided to further confirm a significant energy efficiency gain of the proposed ...

2010-01-01

345

Intersociety energy conversion engineering conference, 20th, Miami Beach, FL, August 18-23, 1985, Proceedings. Volumes 1, 2, and 3  

International Nuclear Information System (INIS)

Topics related to aerospace power are discussed, taking into account trends and issues of military space power systems technology, space station power system advanced development, the application and use of nuclear power for future spacecraft, the current status of advanced solar array technology development, the application of a parabolic trough concentrator to space station power needs, life test results of the Intelsat-V nickel-cadmium battery, and metal hydride hydrogen storage in nickel hydrogen batteries. Other subjects explored are concerned with alternative fuels, biomass energy, biomedical power, coal gasification, electric power cycles, and electric propulsion. Attention is given to an advanced terrestrial vehicle electric propulsion systems assessment, fuel cells as electric propulsion power plants, a sinewave synthesis for high efficiency dc-ac conversion, steam desulfurization of coal, leadless transfer of energy into the body to ...

1985-08-18

346

Highlights of design and construction of Sendai Nuclear Power Station Unit No.2  

International Nuclear Information System (INIS)

As for No.2 plant in Sendai Nuclear Power Station, which is the fourth nuclear power generation facilities in Kyushu Electric Power Co., Inc., all works have been completed, and at present, the final trial operation is under way. In No.2 plant, many new techniques for raising the reliability and safety, improving the maintainability and reducing radiation exposure were introduced on the basis of the operation experience of PWRs obtained so far, similarly to No.1 plant. In this paper, the main items of the new techniques related to the design and construction of the plant are reported. No. 2 plant is a first improved and standardized plant having the thermal output of 2660 MW for standard three-loop PWRs, and the rated power output was set at 890 MW. As for the turbine, TC6F-40 in was adopted. As the improved design, a large reactor containment vessel, 17 x 17 type 9-grid fuel, improved steam generators, a reactor vessel cover of one-body type, a titanium tube ...

1985-01-01

347

Grouted pile study at Cranberry Jct: Nanticoke GS (generating station) - Longwood TS (transmission station)  

Energy Technology Data Exchange (ETDEWEB)

A field study was conducted in Ontario to evaluate the suitability of grouted piles for transmission tower foundations. The grouted piles were assessed in terms of the installation procedure and its foundation performance subjected to uplift loads. Two types of grouted piles, the H-pile and the pipe-pile, were evaluated and compared with conventional ungrouted H-pile foundations. Difficult soil conditions were encountered consisting of a deep deposit of loose to compact sand with a high water table. Both the grouted pipe-pile and the grouted H-pile developed uplift capacities more than double that of the conventional H-pile with the same embedment length at the test site. The grouted H-pile is recommended as a viable transmission line foundation in weak soils due to the significant improvement in its foundation performance, with minor modifications to the construction procedure. 3 refs., 17 figs., 12 tabs.

1990-09-28

348

Fuel spray evolution; Comparison of experiment and CFD simulation of nonevaporating spray  

Energy Technology Data Exchange (ETDEWEB)

Detailed spray characteristics were obtained for a small-capacity, pressure-swirl atomizer using an Aerometrics phase-Doppler particle analyzer. Measurements included drop size and velocity distributions, liquid volume fluxes, and air velocities at four axial locations, 25,50,75, and 100 mm, with complete radial traverses at each location. Drop size results were compared with measurements from a Malvern laser-diffraction instrument, and integrated liquid volume fluxes were compared with measured flow rates to estimate measurement uncertainties. Drop sizes measured by the two independent techniques and area-weighted-averaged over the radial traverses at each of the four axial stations varied on average by less than 4 percent. Integrated volume flux measurements by the phase-Doppler instrument at four axial stations differed from the nozzle flow rate by at most 19 percent, with some of the difference due to evaporation. The phase-Doppler data ...

1989-01-01

349

Failure analysis of CO_2 anti-freezing heater at Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

In this paper, an investigation was performed on a failure pressure vessel, which was as an anti-freezing heater for General Gas Storage and Distribution (SGZ) system. Evident and serious deformation was observed on the body of the vessel. A metallurgical investigation was conducted to establish the mechanism and cause of deformation of the anti-freezing heater at Daya Bay PWR station in China. The investigation, which was performed on specimens cut from the most serious area deformed of the vessel, included macroscopic examination and microscopy examination. The results of the examinations showed that some lamellar pearlite in the microstructure were already spheroidized. It was confirmed that the vessel was operated at high temperature. Stress analysis for the vessel was conducted. And it was confirmed that, in ideal conditions, the vessel would be deformed at around 420 C. The overall results of the investigation showed that the failure of the protected ...

2002-09-23

350

Electrical grid stability and its impact on nuclear power generating stations  

Energy Technology Data Exchange (ETDEWEB)

Electrical power is generated by steam turbines (steam being produced by coal, oil, gas or nuclear reactors), hydro units, gas turbines, internal combustion engines, jet engines, and pumped storage plants. Nuclear Power Plants generate only 15% of the total electrical power in the US. Nuclear Power Plants being cheaper to run are generally base loaded. The pumped-storage and gas turbine plants have ideal characteristics for peaking duty. In the pumping mode, pumped storage plants are used to provide additional system load and in the generating mode, they supply reactive power during peak load demands. Gas turbine plants have higher running costs, but are used as peaking units with a fast start capability. Fossil power plants need a minimum of 1 hour to stabilize expansion in the boiler and turbine generator. Due to a more competitive power supply market due to deregulation, most of the utilizes plan generation only for the next three years. This paper discusses the generation control, ...

1997-12-31

351

Durability of bare and anodised aluminium in atmosphere of very different corrosivities I. Bare aluminium; Durabilidad del aluminio desnudo y anodizado en atmosferas de muy diferentes corrosividades. I. Aluminio desnudo  

Energy Technology Data Exchange (ETDEWEB)

The behaviour of bare aluminium is studied in atmospheric exposure at 11 natural testing stations with salinity levels ranging between 2.1 and 684 mg Cl''- m''-2 d''-1. In atmospheres of low or moderate aggressivity aluminium behaves as a passive material, though the insignificant corrosion that is produced is sufficient to spoil its appearance. In contrast, at salinity levels of 50 mg Cl''- m''-2 ''-1 or above, aluminium is susceptible to pitting corrosion even in the first year of atmospheric exposure, or in the second year at salinities of {<=} 10 mg Cl''- m''-2 d''-1. For comparative purposes, results are included for aluminium protected with an anodic film of 28 {mu}m thickness exposed at the same testing stations. A 28 {mu}m anodic film, correctly sealed, prevents the risk ...

2004-07-01

352

Drought analysis of Nakdong River Basin based on multivariate stochastic models  

Energy Technology Data Exchange (ETDEWEB)

In this study, drought analysis of annual flows of Jindong, Hyunpoong, and Waekwan stations located at Nakdong River Basins was performed based on multivariate stochastic models. The stochastic models used were multivariate autoregressive model(MAR) and multivariate contemporaneous (MCAR) model. MCAR(1) and MAR(1) models were selected to be appropriate models for these stations based on skewness test of normality, test of uncorrelated residuals, and correlograms of the residual series of each model. The statistics generated by MCAR(1) model and MAR(1) model resembled very closely those computed from historical series. The drought characteristics such as run length, run sum, and run intensity were fairly well reproduced for the various lengths of generated annual flows based on the MCAR(1) and MAR(1) models. Thus, these drought characteristics may give the important information in planning mid or long term water supplying systems. (author). 18 ...

1997-04-30

353

Design of the heat receiver for the U.S./Russia solar dynamic power joint flight demonstration  

Energy Technology Data Exchange (ETDEWEB)

A joint US/Russia program is being conducted to develop, fabricate, launch, and operate a solar dynamic demonstration system on Space Station Mir. The goal of the program is to demonstrate and confirm that solar dynamic power systems are viable for future space applications such as the International Space Station Alpha. The major components of the system include a heat receiver, a closed Brayton cycle power conversion unit, a power conditioning and control unit, a concentrator, a radiator, a thermal control system, and a Space Shuttle carrier. This paper discusses the design of the heat receiver component. The receiver comprises a cylindrical cavity, the walls of which are lined with a series of tubes running the length of the cavity. The engine working fluid, a mixture of xenon and helium, is heated by the concentrated sunlight incident on these tubes. The receiver incorporates integral thermal storage, using a eutectic mixture of lithium ...

1995-12-31

354

Core and containment safety analyses for the reduction of boron concentration in the boron injection tank of Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

The design boron concentration of the Boron Injection Tank (BIT) in Daya Bay Nuclear Power Station is 21000 #mu#g/g. The BIT should operate under high temperature to avoid boron crystallization, causing higher evaporation, frequent water makeup, higher deposition and pipe blockage to decrease the operability of the safety injection system. The author proposes to decrease the boron concentration in BIT from 21000 #mu#g/g to 7000 #mu#g/g to solve the existing problem. The safety analyses (core DNBR and containment response) are conducted and other impacts are evaluated for the BIT reduction. The analysis results show that the core DNBR meets the safety criterion and the containment pressure is within the design value for the steam line rupture accident after the BIT reduction. The feasibility study report of Daya bay BIT reduction has been approved by NNSA. The site implementation of BIT reduction has been finished successfully

1999-12-01

355

Childhood cancer in the surroundings of German nuclear power plants: report of an ongoing epidemiological study; Krebs bei Kindern in der Umgebung von Kernkraftwerken: Bericht zu einer laufenden epidemiologischen Studie  

Energy Technology Data Exchange (ETDEWEB)

Epidemiological studies could not show an association between ionising radiation of nuclear power stations in routine operation and the incidence of childhood cancer, yet. The following report presents a case control study conducted by the German Childhood Cancer Registry since autumn 2003. All children in the study region, who were diagnosed with cancer between 1980 and 2003 at an age below five are included. In the first part of the study we investigate whether children with cancer (cases) lived closer to the respective nuclear power stations compared to random children without cancer (controls). In the second part, for a subgroup of cases and controls we conduct computer assisted telephone interviews regarding confounders possibly associated with the exposure of ionising radiation and childhood cancer. Results are expected by the end of 2006. (orig.)

2006-07-01

356

Analysis of solar receiver flux distributions for US/Russian solar dynamic system demonstration on the Mir space station  

Energy Technology Data Exchange (ETDEWEB)

The United States and Russia have agreed to jointly develop a solar dynamic (SD) system for flight demonstration on the Russian Mir space station starting in late 1997. Two important components of this SD system are the solar concentrator and heat receiver provided by Russia and the US, respectively. This paper describes optical analysis of the concentrator and solar flux predictions on target receiver surfaces. The optical analysis is performed using the code CIRCE2. These analyses account for finite sun size with limb darkening, concentrator surface slope and position errors, concentrator petal thermal deformation, gaps between petals, and the shading effect of the receiver support struts. The receiver spatial flux distributions are then combined with concentrator shadowing predictions. Geometric shadowing patterns are traced from the concentrator to the target receiver surfaces. These patterns vary with time depending on the chosen Mir flight attitude and ...

1995-12-31

357

Analysis of dose rate build-up in Tarapur Atomic Power Station unit-4  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station Unit-4 was made critical on 6th March 2005. Since radiation field builds up with the power level due to formation of fission products and activation products in different systems. Radiation dose rates were recorded from different areas using Area Radiation Monitors (ARMs) installed at different areas. These monitors are connected to Radiation Data Acquisition System (RADAS). The trend of radiation field build-up was also analyzed by making survey of different plant areas at various power levels and comparison was made with RADAS readings. The results obtained were compared with 220 MWe dose rates. This study discusses about the dose rates observed at accessible area, shut down accessible area and hotspots observed during the early stage of operation of the reactor. The attempt was also made to find the contributing factors of the high dose rates. It was found that the finding of the study was utilized for the shielding augmentation. ...

2005-11-23

358

Alteration of installation of reactors (alteration of No. 1 and No. 2 reactor facilities) in the Sendai Nuclear Power Station, Kyushu Electric Power Co. , Inc  

Energy Technology Data Exchange (ETDEWEB)

The Nuclear Safety Commission presented the report to the Minister of International Trade and Industry on April 5, 1984, after the careful investigation and deliberation on the alteration of installation of No.1 and No.2 reactor facilities in the Sendai Nuclear Power Station. The technical capability of Kyushu Electric Power Co., Inc., was recognized to be adequate. It was judged that the safety after this alteration of installation of the reactor facilities can be ensured. The main items of examination were as follows. The mechanical, nuclear and thermo-hydraulic designs of 17 x 17 B-type fuel assemblies were regarded as adequate. The coexistence of A-type and B-type fuel assemblies does not cause any problem about the safety. The safety at the time of abnormal transient change and accident in the mixed fuel assembly core was confirmed. In No.2 reactor, the degree of enrichment of the fuel for replacement and the number of fuel assemblies to be replaced are ...

1984-08-01

359

Acid-deposition research program. Volume 2. Design of the emission inventory: emission inventory of sulfur oxides and nitrogen oxides in Alberta  

Energy Technology Data Exchange (ETDEWEB)

To predict air quality properly at a given location, it is necessary to identify all emission sources that will have significant impact at that location. Furthermore, the atmospheric pollutants that are emitted by these sources must be identified and quantitatively characterized. Once the air-quality predictions have been made, it is desirable to have some historical air-quality data for comparison. An efficient means of obtaining this information is through the use of detailed emission inventories and an inventory of air-quality-monitoring stations. Therefore, as part of the Alberta Government/Industry Acid Deposition Research Program (ADRP), three comprehensive inventories have been developed, namely: a sulfur dioxide (SO/sub 2/) emission inventory, a nitrogen oxides (NOx) emission inventory, and an inventory of air-quality-monitoring stations. Volume 2, Design of the Emission Inventory, presents detailed information on the classification ...

1987-11-01

360

A pilot application of risk-based methods to establish in-service inspection priorities for nuclear components at Surry Unit 1 Nuclear Power Station  

International Nuclear Information System (INIS)

As part of the Nondestructive Evaluation Reliability Program sponsored by the US Nuclear Regulatory Commission, the Pacific Northwest Laboratory is developing a method that uses risk-based approaches to establish in-service inspection plans for nuclear power plant components. This method uses probabilistic risk assessment (PRA) results and Failure Modes and Effects Analysis (FEMA) techniques to identify and prioritize the most risk-important systems and components for inspection. The Surry Nuclear Power Station Unit 1 was selected for pilot applications of this method. The specific systems addressed in this report are the reactor pressure vessel, the reactor coolant, the low-pressure injection, and the auxiliary feedwater. The results provide a risk-based ranking of components within these systems and relate the target risk to target failure probability values for individual components. These results will be used to guide the development of improved inspection ...

361

Yucca Mountain Task 4, Final report FY 1993  

Energy Technology Data Exchange (ETDEWEB)

Four major projects at UNRSL have been supported by NWPO-Neotectonics Yucca Mountain Task 4 funds during the last year: (1) Operation and analysis of data from the UNRSL microearthquake network at Yucca Mountain. (2) Continued operation, maintenance, and calibration of three broadband stations. Limited data analysis was also initiated. (3) Continued review by Dr. Brune of documents and literature related to seismic hazard and tectonics of the Yucca Mountain region. (4) Testing of noise levels in boreholes.

1993-09-30

362

Tidd experience prepares hot gas cleaning technology for commercialization  

Energy Technology Data Exchange (ETDEWEB)

Pressurized fluidized bed combustion (PFBC) is an emerging coal-fired, combined-cycle power generation technology nearing commercial status through several operating and planned demonstration plants throughout the world. Current-generation PFBC plants use ``ruggedized`` gas turbines that can tolerate dust loading common with conventional cyclone gas cleaning. The next generation of PFBC will apply advanced hot gas cleaning systems that will reuse the dust loading to low levels acceptable to high performance, industrial gas turbines. These advances should result in performance and cost advantages. This article examines the demonstration of PFBC technology at Tidd power station.

1995-09-01

363

The solution to avoid protection fuses' failure of the driving motor of the turbine-generator set during its startup in Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

Based on a detailed analysis of the inter-relationship in the current, voltage, electromagnetic torque and ratio of the difference between the speed of rotor and the speed of rotary magnetic field to the later in the motor, the root cause was point out, which leads to the protection fuses' failure of the motor in the starting stage, which drives the turbine-generator set to rotate at low speed before its startup. Two solutions to avoid the situation are proposed, too. (authors)

2005-09-01

364

Technology transfer in the field of small hydroelectric power stations; Technologietransfer im Bereich Kleinwasserkraft  

Energy Technology Data Exchange (ETDEWEB)

The rate at which full-scale technology transfer takes place depends on the quality of the supply companies, i.e. training, organisational development and product infrastructure. These parameters are discussed for the example of a water mill, and a flow diagram is presented. [Deutsch] Wie rasch ein umfassender Transfer in Frage kommt, entscheidet sich mit der Qualitaet und dem Niveau der zuliefernden Betriebe. Hierbei sind Ausbildung, Organisationsentwicklung und Produktionsinfrastruktur besonders angesprochen. Fuer eine Wassermuehle werden diese Parameter konkret eroertert und an Durchlaufdiagrammen erlaeutert. (GL)

1997-12-31

365

Substantiation of recommendations for ensuring the design service life of heat-transfer tubes used in a PGV-1000MKP steam generator  

Science.gov (United States)

We present the results obtained from tests and studies carried out on the model of tube bundles for a PGV-1000 horizontal steam generator that were conducted for experimentally substantiating the design service life of a steam generator tube bundle intended for use at new nuclear power stations equipped with a PGV-1000MKP steam generator. Measures taken to minimize the incipience and development of local corrosion damage to the heat-transfer tubes and ensure their design service life are substantiated and confirmed.

2011-03-01

366

Study for application of multi fuel technology in the Brazilian automobilistic market; Estudo para aplicacao da tecnologia multi combustivel no mercado automobilistico brasileiro  

Energy Technology Data Exchange (ETDEWEB)

The objective of this work is a study for the application of a new technology that will be used in the engine management system in the vehicle; where the final consumer can opt for the inquiry performance or seeking an economy for the fuel consumption depending on its daily use and of the prices offered in the gas stations. Flexible Fuel is a technology in development for the automobile market that mixes the use of two fuels (gasoline and ethanol) and their mixtures in the internal combustion engine. (author)

2006-07-01

367

Standardization/improvement and technical development of light water reactor power station in Japan(BWR)  

Energy Technology Data Exchange (ETDEWEB)

In order to realize improve of reliability and economy by duplicate production, rapid supply of repair parts from standardized storage, such were expected as to have continuous order of standardized plant, to ignore site condition, to avoid expansion of regulatory requirement. Standardization program was planned to limitedly promote standardization of safety-related design concept, major specification and basic system composition of reactor and primary systems. The area of standardization had been tried to expand to BOP such as general arrangement and rad-waste system.

1985-07-01

368

Southern receiver system: Environmental impact assessment status report: Conawapa to Winnipeg Power Transmission Complex  

Energy Technology Data Exchange (ETDEWEB)

The Conawapa-Winnipeg Power Transmission Complex includes five interrelated transmission and conversion facilities. This booklet describes work done on the upgrade of the southern receiver system, one component of the complex. The southern receiver system is composed of a network of high voltage transmission lines and station facilities. The booklet includes a description of the upgrade, the project setting, short and long-term effects and impact management, and the next steps to be taken in the process, including the regulatory process and public consultation.

1992-01-01

369

Soil engineering properties and earthworking problems of coal ash and red mud  

Energy Technology Data Exchange (ETDEWEB)

A study was undertaken of problems encountered in the use of thermal power station coal ash and red mud (an aluminium smelting residue) as a banking or filling material, the aim being the effective utilization of these substances. Like clinker, coal ash and red mud can also be used as improvers, but there are various problems such as absorption swelling, strong alkalinity, and the difficulty of controlling the moisture content. Certain measures have to be carried out in on-site use to combat these problems. (11 refs.)

1982-01-01

370

Self-optimized Coverage Coordination and Coverage Analysis in Femtocell Networks  

CERN Document Server

This paper proposes a self-optimized coverage coordination scheme for two-tier femtocell networks, in which a femtocell base station adjusts the transmit power based on the statistics of the signal and the interference power that is measured at a femtocell downlink. Furthermore, an analytic expression is derived for the coverage leakage probability that a femtocell coverage area leaks into an outdoor macrocell. The coverage analysis is verified by simulation, which shows that the proposed scheme provides sufficient indoor femtocell coverage and that the femtocell coverage does not leak into an outdoor macrocell.

2009-01-01

371

Safety analysis and justification for modification of auxiliary feed-water system in Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

The major feed-water line break accident is re-analyzed, which is based on Guangdong Daya Bay nuclear power station final safety analysis report, to justify the impacts of the decreasing of auxiliary feed-water flow rate on the safety margin in Daya Bay. The results showed that the accident analysis can meet the demands of acceptance criteria with the auxiliary feed-water flowrate decreasing from 45 m"3/h to 41.8 m"3/h, and enough safety margin is still retained

2002-06-01

372

Role of the transport in management of MSW. Part 1.: global balance  

International Nuclear Information System (INIS)

An important aspect, which has to be considered in terms of municipal solid waste (MSW) management, is the stage of collection. The emissions generated from these systems can arrive to values that are of the same order of magnitude of emissions from combustion of waste in waste-to-energy plants. The present work faces the problem of transport, from intermediate station to the center of final combustion, placing attention to the emissions from scenarios that has been selected between real systems of management. This analysis can lead to highlight some important elements that can be useful to minimize the impacts.

373

Repair welding of a low pressure runner with cracks; Reparaturschweissung eines rissbehafteten Niederdrucklaeufers  

Energy Technology Data Exchange (ETDEWEB)

In the power station West Block 2 at Voerde (Federal Republic of Germany), cracks in the final stage of the shaft were determined at the ND1 rotor of the 350 MW condensation tube was determined. A purely mechanical preparation of the crack was not possible due to the depth of the crack. A substitute rotor was not available. A repair solution was developed covering a welding of a new shaft section to the existing rotor. The authors of the contribution under consideration report on the damage, cause of the damage, repair solution and the process of repair.

2010-07-01

374

Remote Sensing | Special Issue: Global Positioning Systems (GPS) and Applications  

Wastenet

...htmE-Mail: Interests: geodesy; GPS/GNSS technology and applications; navigation; precise positioning algorithms; continuously operating GPS/GNSS reference station infrastructure Published Papers Click here to see a list of 3 papers that have been published in this special issue. Special Issue Information Submission Manuscripts should be submitted online at www.mdpi.com by registering and logging in to this website. Once you are registered, click here to go to the submission form. Manuscripts can be submitted until the deadline. Papers will be published continuously (as soon as ...

375

Relining of scrubbers in flue gas desulfurization plants  

Science.gov (United States)

Rubber lining is used as a corrosion protection material in European flue gas desulfurization plants, for scrubbers, tanks, pipe systems, etc. Although these rubber linings can last more than 15 years, relining still is necessary. The difficulty of shutting down power station units requires that the time scale of this replacement be kept to a minimum. High-pressure water systems have proven successful as an efficient method for removal of the old lining. The working steps and time scale are demonstrated for one such relining case.

1999-09-01

376

On the threshold of the 21st Century in the Soviet Union  

International Nuclear Information System (INIS)

In the last 30 years the production of electricity in the USSR has increased 14-fold, probably attaining 1540 billion kWH in 1985. Nuclear generation will provide the bulk of future increases of consumption, using both water-cooled and uranium/graphite reactors; stations of up to 1.5 million kW are in service. The USSR is also in the fore-front of attempts to exploit thermonuclear power. The USSR is also conducting experiments with renewable sources of energy such as solar, geothermal, wind and wave power and with magnetohydrodynamic generation. (D.A.J.).

377

Nuclear design analysis of wolsung-1 CANDU-PHW nuclear generating station  

International Nuclear Information System (INIS)

A combination of computer codes such as LATREP, HWRAXAV and CITATION is utilized in an attempt to analyze the nuclear design characteristics of the CAXDU-PHWR of the Wolsung Unit 1. The major nuclear properties to be computed are the lattice properties of CANDU fuel channel and the core channel power distribution. The computed results are compared with the preliminary safety reports documentation for the Wolsung reactor. The observed discrepancies between our computations and the preliminary safety reports values are discussed in terms of incomplete information on the description of the core configuration in the preliminary safety reports and the different calculation methods. (author).

1978-01-01

378

Mega-components from steel casting for power plant technology; Megakomponenten aus Stahlguss fuer die Kraftwerkstechnik  

Energy Technology Data Exchange (ETDEWEB)

Voestalpine AG (Linz, Austria) produces heavy steel for steam turbines, compressors for the promotion of oil and gas as well as for the chemical industry, mechanical engineering and for the offshore technology. A weight range between 1 and 200 tons can be covered. The author of the contribution under consideration is limited to characteristics which have to be managed by a large steel foundry within the range of the steam power plants. This is described on the basis of produced steam turbines for power stations in the highest performance segment (1,600 MW).

2010-07-01

379

MILSTAR's flexible substrate solar array: Lessons learned, addendum  

Science.gov (United States)

MILSTAR's Flexible Substrate Solar Array (FSSA) is an evolutionary development of the lightweight, flexible substrate design pioneered at Lockheed during the seventies. Many of the features of the design are related to the Solar Array Flight Experiment (SAFE), flown on STS-41D in 1984. FSSA development has created a substantial technology base for future flexible substrate solar arrays such as the array for the Space Station Freedom. Lessons learned during the development of the FSSA can and should be applied to the Freedom array and other future flexible substrate designs.

1990-01-01

380

KOMET 650: investigation of materials for use in steam turbines at temperatures up to 650 C; KOMET 650: Erprobung von Materialien fuer den Einsatz in Dampfturbinen bei Temperaturen bis 650 C  

Energy Technology Data Exchange (ETDEWEB)

The report covers the results of exposing materials for steam turbines to increased steam temperatures in two modules of the KOMET 650 testing facility at the Westfalen power plant. Ferritic/martensitic steels with 9 to 12% Cr and austenite and nickel-based alloys were investigated. Some experimental coatings on low-alloy Cr steel were also tested. The principal findings are presented. It will become possible to construct advanced power stations to be operated at higher temperatures. (orig.)

2008-07-01

381

Hydraulic braking system for loads subjected to impacts and vibrations  

International Nuclear Information System (INIS)

This invention concerns a hydraulic braking system for loads subjected to impacts and vibrations. These double acting telescopic type hydraulic braking systems possess significant drawbacks linked to possibly important hydraulic leaks due to (a) the use of many dynamic seals in such appliances and (b) the effects of the environment of the system on these seals, particularly when employed in nuclear power stations where the seals reach significant temperatures and are subjected to radiation. Under this invention a remedy is suggested to such drawbacks by integrating means to offset automatically the leaks and the accumulation of hydraulic fluid expansions, as well as facilities to show if such leaks have occurred.

382

Feedwater control device of the steam generator in an atomic power station  

International Nuclear Information System (INIS)

Purpose: In a case of automatically controlling the water level at the time of generating a lower power, to impact the followability of the control necessary for the power variation of the steam generator thereby to obtain good controllability. Constitution: A signal of deviation of water level of a steam generator and its set value and a signal of a difference between the temperature of the primary coolant in the high temperature side pipeline and that of the primary coolant in the low temperature side pipeline are used to automatically or manually control the flow quantity of water fed to the steam generator. (Yoshihara, H.).

383

FORTUM Participation in BARCOM Round Robin pre-test simulation: mid-term analysis  

Energy Technology Data Exchange (ETDEWEB)

In the study a preliminary mid-term analysis of the BARCOM test model is presented. The BARCOM test model is a 1:4 scale of an existing pressurized heavy water reactor (PHWR) pre-stressed concrete inner containment of 540 MW Tarapur Atomic Power Station 3 and 4 units in India. The goal of this midterm analysis is to illustrate the modeling approach and achieve a prediction of the failure mode. The analysis was carried out using ABAQUS/CAE and ABAQUS/EXPLICIT version 6.7-EF1 software

2009-07-01

384

Effect of power supply ripple on emittance growth in the collider  

Energy Technology Data Exchange (ETDEWEB)

Power supply ripple at frequencies of 720 Hz and its harmonies is expected to affect the motion of particles in the collider. These ripple frequencies are nearly resonant with the betatron frequencies. To estimate the tolerable ripple levels, we have tracked particles through the complete nonlinear lattice for 10[sup 4] turns with ripple fed from 10 different power stations and including up to 7 different ripple frequencies. We presently estimate that relative ripple amplitudes must be below the 10[sup 8] level for there to be no significant impact on the emittance over the short term.

1993-05-01

385

Effect of power supply ripple on emittance growth in the collider  

Energy Technology Data Exchange (ETDEWEB)

Power supply ripple at frequencies of 720 Hz and its harmonies is expected to affect the motion of particles in the collider. These ripple frequencies are nearly resonant with the betatron frequencies. To estimate the tolerable ripple levels, we have tracked particles through the complete nonlinear lattice for 10{sup 4} turns with ripple fed from 10 different power stations and including up to 7 different ripple frequencies. We presently estimate that relative ripple amplitudes must be below the 10{sup 8} level for there to be no significant impact on the emittance over the short term.

1993-05-01

386

Effect of pH on the pitting corrosion of austenitic stainless steel in chloride solution  

International Nuclear Information System (INIS)

This paper deals with the pitting corrosion of evaporators in the liquid - radwaste system of nuclear power stations. Corrosion testrs were conducted by the anodic polalization of specimen in the chloride solution. (1) The initiation of the pitting in SUS 304, SUS 316 stainless steels was inhibited by addition of NaOH and H_3BO_3, however, these addition had no effect on the pitting propagation. (2) Inconel 625 had the resitivity against the pitting initiation superior to that of stainless steels, but this was not necessarily in the case of the pitting propagation. (3) It is noticed for pitting prevention that the environmental and material effect on the pitting initiation differed from that on the pitting propagation. (author).

387

Dynamic stabilizer on-line experience  

Energy Technology Data Exchange (ETDEWEB)

A brief description is presented of the Westinghouse Torsional Dynamic Stabilizer, which was developed primarily as a countermeasure to ''torsional interaction'' subsynchronous resonance. Two such systems were installed and commissioned at the San Juan Generating Station, Waterflow, New Mexico in July, 1980. This paper describes the maintenance procedures and operating experience to date of these two units. The only known instance of operation at the high level bias point of the Stabilizer appears to indicate that the unit helped to dampen a turbine-generator shaft oscillation transient.

1984-01-01

388

Cutaneous leishmaniasis associated with jungle training.  

Science.gov (United States)

In November 1977, 627 soldiers belonging primarily to the First Battalion, 82nd Airborne Division, stationed at Fort Bragg, were sent to the Canal Zone, Panama, for jungle warfare training. A medical surveillance program incorporating pre- and post-evaluations over a 6-month period with dermatologic examinations, questionnaires, and serologic tests was established. Ten cases of cutaneous leishmaniasis (1.6/100 men) were diagnosed by positive Leishmania culture. The demonstrated lack of sensitivity and specificity of the indirect fluorescent antibody test and the direct agglutination test render these serological methods useless as diagnostic screening methods in the early stages of this disease. PMID:7406101

1980-07-01

389

Correct monitoring of stationary battery systems; Stationaere Batteriesysteme richtig ueberwacht  

Energy Technology Data Exchange (ETDEWEB)

There are many applications that necessitate reliable and permanent power supply, e.g. power stations, airports, computer centers or hospitals. The stationary battery systems must be monitored by efficient systems, e.g. Batlog. (orig.) [Deutsch] Viele Anwendungen verlangen eine permanent verfuegbare und zuverlaessige Stromversorgung. Kraftwerke, Flughaefen, Rechenzentren oder Krankenhaeuser muessen ihre Prozesse auch bei einem Netzausfall oder einer Versorgungsunterbrechung weiterbetreiben. Dies gelingt nur, wenn sich der entsprechende Energiespeicher in einsatzbereitem Zustand befindet. Die Ueberwachung der stationaeren Batterieanlagen erfordert leistungsfaehige Systeme wie Batlog. (orig.)

1998-10-01

390

Collaboration work for nuclear power building using 3D CAD information  

Energy Technology Data Exchange (ETDEWEB)

In the construction work for the Unit No.5 Turbine Building at Hamaoka Nuclear Power Station, the collaboration work for the planning and the coordination of the building construction and the machinery installation was carried out utilizing three-dimensional computer aided design (3D CAD) information. It was the first time in Japan for a building constructor and a plant manufacturer to work together, exchanging 3D CAD data of the whole building and adjusting the construction schedule. It was made possible to confirm the correspondence concerning the planning of both companies from the primary stage of the project by the total process simulation and to adjust on-going work precisely by the partial process simulation.

2006-02-15

391

Collaboration work for nuclear power building using 3D CAD information  

International Nuclear Information System (INIS)

In the construction work for the Unit No.5 Turbine Building at Hamaoka Nuclear Power Station, the collaboration work for the planning and the coordination of the building construction and the machinery installation was carried out utilizing three-dimensional computer aided design (3D CAD) information. It was the first time in Japan for a building constructor and a plant manufacturer to work together, exchanging 3D CAD data of the whole building and adjusting the construction schedule. It was made possible to confirm the correspondence concerning the planning of both companies from the primary stage of the project by the total process simulation and to adjust on-going work precisely by the partial process simulation.

2006-02-01

392

Characteristics of cosmic ray pole-equator anisotropy derived from spherical harmonic analysis of neutron monitor data  

International Nuclear Information System (INIS)

The spherical harmonic analysis of cosmic ray neutron data from the worldwide network neutron monitor stations during the years 1966 to 1969 was carried out. The second zonal harmonic component obtained from the analysis corresponds to the Pole-Equator anisotropy of the cosmic ray neutron intensity. Such an anisotropy makes a semiannual variation. In addition to this, it is shown that the Pole-Equator anisotropy makes a variation depending on the interplanetary magnetic field (IMF) sector polarities around the passages of the IMF sector boundary. A mechanism to interpret these results is also discussed.

1985-08-01

393

An application of the analysis of variance of measures repeated in an experiment with heavy metals  

International Nuclear Information System (INIS)

A revision of some basic concepts related to the analysis of variance of repeated measures is presented within an ecological context topics such as the types of experiments in which the technique is applicable, the hypotheses of interest, and its preference over other traditional techniques such as regression and conventional analysis of variance, are discussed. As an example, the technique was successfully applied to an experiment carried out at Cienaga Grande de Santa Marta, Colombia, in which the concentration of cadmium #mu#g/g in leaves of the black mangrove Avicennia germinans was measured in several monitoring stations and throughout several sampling intervals representing seasons.

1997-11-01

394

Ambient Air Radionuclide Concentrations at and near TA-50 from 2003 through the First Quarter of 2004  

Energy Technology Data Exchange (ETDEWEB)

The Meteorology and Air Quality (MAQ) group at Los Alamos National Laboratory maintains and operates a large network of environmental air samplers called AIRNET. Some of these samplers are located near Material Disposal Area C at TA-50, a low-level radioactive waste burial site in the semiarid environment of the Pajarito Plateau, near Los Alamos. AIRNET sampling media consist of a filter and silica gel. They are exchanged once every 2 weeks. Presented are 5 months of air sampling results for 5 stations operating in the vicinity of Material Disposal Area C.

2005-09-05

395

A review of the behaviour of alloy 800 in liquid sodium  

International Nuclear Information System (INIS)

Although there is service experience of Alloy 800 as tubing for superheaters in conventional and nuclear (HTR) power stations and in PWR heat exchangers, there is no corresponding service experience in sodium-cooled fast reactor steam generators. However, some limited experimental studies have been made of corrosion behaviour, and of possible structure modifications and effects on mechanical properties which occur during exposure of this material to a high temperature sodium environment, and these are summarised in the paper. It is concluded that further work needs to be done before Alloy 800 can be confidently endorsed for use as tubing in fast reactor steam generators. (author).

396

Terra Nova: taming the North Atlantic  

Energy Technology Data Exchange (ETDEWEB)

The Terra Nova offshore oil project is described, with emphasis on the construction of the Terra Nova Floating Production Storage and Offloading (FPSO) vessel, the first such vessel constructed for the harsh environment of the North Atlantic off Newfoundland, the site of an oil field that is expected to produce 125,000 to 150,000 barrels of oil per day starting in 2001. The vessel has a double-hull, made of 3,000 tons of reinforced steel to protect it from ice in the form of massive icebergs or crusty 'packs'. The vessel has the world's largest quick release turret, meaning that the vessel can be quickly disconnected from its turret and mooring in the event of an encroaching iceberg, and then reconnected in an environmentally sound way. Apart from its extremely rugged construction, protecting the FPSO vessel against icebergs is accomplished by way of 'hosing down' (by melting by powerful streams of water) or 'lassoing' (by ...

2000-08-01

397

Application of photogrammetry, remote sensing and GIS in the environmental monitoring of the Deutsche Steinkohle AG; Einsatz von Photogrammetrie, Fernerkundung und GIS im Umweltmonitoring der Deutschen Steinkohle AG  

Energy Technology Data Exchange (ETDEWEB)

Due to legal restrictions, the German hard coal mining company Deutsche Steinkohle AG (DSK) is obliged to conduct a monitoring on surface changes (subsidence) caused by mining activity (e.g. topographic surface, groundwater, water, flora and fauna, soil). To fulfill legal demands and to do this effectively, process chains by use of Photogrammetry, Remote Sensing and Geo-Informationssystems (GIS) have been established. Photogrammetric methods are used to generate high resolution Digital Elevation Models (DEM) from which in combination with subsidence data geometrical changes at the topographic surface are deduced. The potential use of active sensors (Laser Scanning and Synthetic Aperture Radar Systems) to deduct DEM has been investigated. The applicability of SAR satellite data to detect and observe subsidence and resulting movements - point wise or with spatial extent - using differential SAR Interferometry (dInSAR) as well as persistent scatterer technology (here: ...

2006-03-15

398

The hydroclimatology of the United States during El Nino/Southern Oscillation  

Energy Technology Data Exchange (ETDEWEB)

Palmer Drought Severity Index (PDSI) monthly data are analyzed, building on a previous study that investigated the influence of the El Nino/Southern Oscillation (ENSO) on US streamflow. Harmonic analysis is performed using data from 1,035 selected climatological stations, allowing observation of the biennial tendency in climate data. With the middle twelve months defined as the El Nino year (0), an idealized first harmonic fit to a 24-month ENSO composite is computed for each station. By plotting the first harmonic vectors of each station, regions of similar, or coherent, response are identified. The regions identified using PDSI data represent wet conditions in the Gulf of Mexico (Gm1 and GM2) and central (C) US, and dry conditions in the Pacific northwest (PNW) and northeast (NE) US. The PNW region exhibits the strongest interrelationship between ENSO and extreme drought events. Comparing PDSI data results with other ...

1995-12-31

399

Omega process for the use of substitute fuels; Waste energy: Omega-Verfahren zur Verwertung von Ersatzbrennstoffen  

Energy Technology Data Exchange (ETDEWEB)

Only about 25% of residue accumulating in the Federal Republic of Germany is currently used for the purposes of energy. This residue will be converted into fuel for power stations by the Omega process when the dumping of waste with a calorific value in excess of 5 MJ/kg is prohibited with effect from 2005. This oxygen melting process is suitable for the local use of substitute fuels. Waste is converted into a high-quality synthesis gas with a wide range of uses. The Omega process combines drying, thermal decomposition, gasification and melting of the material used in a single-stage process. This is now technologically possible for the first time by combining a metallurgical cupola furnace with a traditional gas producer. The highly-calorific synthesis gas produced by the Omega process can be used in block heat and power stations or as an industrial fuel gas, instead of natural gas. It is also suitable as a starting material for synthesising ...

2003-03-01

400

Municipal solid waste management in Africa: Strategies and livelihoods in Yaounde, Cameroon  

International Nuclear Information System (INIS)

This paper provides an overview of the state of municipal solid waste (MSW) management in the capital of Cameroon, Yaounde, and suggests some possible solutions for its improvement. The institutional, financial, and physical aspects of MSW management, as well as the livelihoods of the population, were analyzed. Our study revealed that distances and lack of infrastructure have a major impact on waste collection. Garbage bins are systematically mentioned as the primary infrastructure needed by the population in all quarters, whether it be a high or low standard community. The construction of transfer stations and the installation of garbage bins are suggested as a solution to reduce distances between households and garbage bins, thus improving waste collection vehicle accessibility. Transfer stations and garbage bins would enable the official waste collection company to expand its range of services and significantly improve waste collection ...

2009-02-01

401

Multi-rotor-stations, a new concept for large-scale wind power stations; Multi-Rotor-Konstruktionen. Ein neues Konzept fuer grosse Windkraftanlagen  

Energy Technology Data Exchange (ETDEWEB)

As an alternative to the usual way of installing wind machines in extended windfarms new concepts are being developed. Several wind turbines are affixed to one support structure and can be aligned together. Drafts of steel constructions developed by students in three diploma theses are presented. The attempt to transform existing design standards requires extensive discussion of possible influence scenarios. Several concepts regarding structure and safety elements are described and evaluated. The design of the support structure is to be seen as a first step to the practicability of the whole concept. A preliminary mass calculation and a specification of further cost factors facilitates the comparison to conventional wind power stations. (orig.) [Deutsch] Als Alternative zur ueblichen Praxis, Windenergieanlagen in Form grossflaechiger Windparks zu bauen, werden Konzepte entwickelt, bei denen mehrere Konverter an einem Tragwerk angeordnet und gemeinsam in den Wind ...

1996-06-01

402

Long-term optimization of fuel loading pattern using genetic algorithms and simulated annealing  

International Nuclear Information System (INIS)

This paper describes Automatic Refueling Planning System (ARPS) for a nuclear power station using Genetic Algorithms (GA) and a Simulated Annealing (SA). ARPS has been developed and verified by applying to the Fugen nuclear power station (NPS), which is a 165MWe, heavy water-moderated, boiling light water-cooled, pressure tube-type reactor developed by JNC utilizing mainly uranium and plutonium mixed oxide (MOX) fuel. Fuel loading patterns have been managed independently in the Fugen NPS since the initial core. A planning of an adequate fuel loading pattern on each operational cycle needs one to two months even for expert core management engineers, for the reason that it has multi-objective optimization and nonlinear problems. In order to achieve the optimum fuel loading pattern and a fuel cost reduction, ARPS has been developed by JNC and CRC Solutions Corporation for the last five years. ARPS firstly generates several thousand fuel loading ...

2003-04-20

403

Experiments in High-Frequency Imaging of the 2004 M6.0 Parkfield Earthquake  

Science.gov (United States)

We attempt to image the rupture propagation of the 2004 M6.0 Parkfield earthquake by analyzing records from the USGS Parkfield seismic array (UPSAR) and other strong-motion stations. The UPSAR array consists of 12 stations distributed over about one square kilometer at a distance of 10~km from the San Andreas fault near Parkfield, California. We employ a method that uses reverse time migration to stack the seismograms at back-projected locations along the fault. We use waveform cross-correlation to align the initial P-wave arrivals and correct for small static time shifts in the records. This forces a coherent image at the hypocenter at the quake origin time. Initial results at later time steps show some evidence of the expected rupture propagation to the north. However, the resolution of the back-projection is limited by the small aperture of the UPSAR array. Records from other strong-motion stations can improve the ...

2006-12-01

404

Estimations of population doses and risk estimates from occupational exposures in Japan, 1978, 2  

International Nuclear Information System (INIS)

The population doses and risks of stochastic effects from occupational exposures in Japan in 1978 were estimated on the basis of a nation-wide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 82,500 workers other than the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the offitial publication of the Japan Nuclear Safety Commission. The total number of workers except for nuclear power stations was estimated to be about 170,000 persons. Radiation works were subdivided as follows: medical works including dental; nondestructive inspectional; non-atomic energy industrial; research and educational; atomic energy industrial and nuclear power industrial. The annual collective dose equivalents were estimated to be about 6,000 man rem for medical workers, 450 man rem for non-destructive inspectional, ...

1981-01-01

405

Corrosion product role on the inhibition of Zn alloy electrodeposit corrosion  

Energy Technology Data Exchange (ETDEWEB)

Electrodeposited Zn alloys with Fe group metals are known to be more resistant than pure Zn. However, the role of the corrosion products on the corrosion inhibition is not considered up to date. The aim of the present work was to examine the composition of corrosion products, which form on the Zn and Zn alloy surfaces under atmospheric corrosion conditions up to 3 year of exposure, trying to correlate it with the differences in their corrosion resistance. Zn corrosion products have been characterized by X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). Corrosion film composition was determined to depend on the sample exposure she, as well on the coating type. During the initial exposure stages oxide film was found to be the principal reaction product (XPS data), which in marine station consists from hydroxide phase exceptionally, while in urban one, contain up to 6-12 % of oxide. Succeeding corrosion products (XRD data) in marine ...

1998-12-31

406

Assessment of audible noise from high voltage transmission lines and a high voltage transformer station  

Energy Technology Data Exchange (ETDEWEB)

The study of audible noise from high voltage transmission lines and a high voltage transformer station was conducted in three parts. Part 1 consisted of long-term measurement and statistical analysis by computer reduction of audible noise as a result of corona discharge from high voltage transmission lines and the associated weather conditions which contribute to this noise. Recommendations are given concerning further computer programming in order to improve the statistical reliability of corona noise presence and reduce the degree of background noise contamination of the present results. Part 2 consisted of categorizing and cataloguing of corona noise spectra from long-term measurements on 550, 735 and 765 kV transmission lines and to provide a library of such sounds on magnetic tape to be used in the ongoing study of corona noise. Twenty-five different corona sound spectra have been identified and documented in a tape library. Average weather conditions ...

1986-11-01

407

The correlation between accelerated and field corrosion tests performed in carbon steel and weathering steel coupons, coated and non-coated; Correlacao entre ensaios acelerados e ensaios de campo em corpos-de-provas de aco carbono e aco patinavel, sem e com revestimento  

Energy Technology Data Exchange (ETDEWEB)

The performance of four different organic coating systems applied to carbon and weathering steel coupons has been assessed in this investigation. applied on the surface of carbon steel and weathering steel coupons. The coupons have been evaluated using five different tests, three field tests and two accelerated tests. The field tests were carried out at three atmospheric stations, located at COSIPA in Cubatao-SP, at Alto da Serra in Cubatao-SP and at Paula Souza in Sao Paulo city. The accelerated tests consisted of (a) exposure to alternate cycles of ultraviolet radiation/condensation combined with salt spray cycles (UVCON combined with Salt Spray) and of (b) exposure to alternate cycles of ultraviolet radiation/condensation combined with the Prohesion test. The performance of the coatings was assessed by visual observation and photographs, using a method based on ASTM D-610, ASTM D-714 and ASTM-1654 standards to rank them. The oxide phases formed on the surfaces ...

2002-07-01

408

Fifteen years of seismic monitoring at the Las Tres Virgenes, BCS, geothermal field; Quince anos de monitoreo sismico en el campo geotermico de Las Tres Virgenes, BCS  

Energy Technology Data Exchange (ETDEWEB)

Seismic monitoring at the Las Tres Virgenes, BCS, geothermal field started in 1992 with an analog station of vertical components detecting a large number of earthquakes of varying magnitudes. In February 1993, a seismic network was installed, composed of six digital stations DR-2000-with S-6000 and S-5000 sensors and three registration channels (N-S, E-W and vertical). This was the basis for the development of a program to correct arrival-time data for P and S waves due to instrument drift. From January to April 1994 and May to August 1995, based on the 170 seismic events recorded, a velocity model was proposed. From December 1995 to July 1996, seismic data were processed and interpreted, and zones of occurrence were determined for events according to magnitude and the predominant noise in the field. From September 2003 to December 2004, 10 seismic stations (permanent and temporary) were installed and monitored and it was ...

2009-07-15

409

Corrective Action Investigation Plan for Corrective Action Unit 409: Other Waste Sites, Tonopah Test Range, Nevada (Rev. 0)  

Energy Technology Data Exchange (ETDEWEB)

This Corrective Action Investigation Plan contains the U.S. Department of Energy, Nevada Operations Office's approach to collect the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit (CAU) 409 under the Federal Facility Agreement and Consent Order. Corrective Action Unit 409 consists of three Corrective Action Sites (CASs): TA-53-001-TAB2, Septic Sludge Disposal Pit No.1; TA-53-002-TAB2, Septic Sludge Disposal Pit No.2; and RG-24-001-RGCR, Battery Dump Site. The Septic Sludge Disposal Pits are located near Bunker Two, close to Area 3, on the Tonopah Test Range. The Battery Dump Site is located at the abandoned Cactus Repeater Station on Cactus Peak. The Cactus Repeater Station was a remote, battery-powered, signal repeater station. The two Septic Sludge Disposal Pits were suspected to be used through the late 1980s as disposal sites for sludge from ...

2000-10-05

410

W-026 acceptance test plan plant control system hardware (submittal {number_sign} 216)  

Energy Technology Data Exchange (ETDEWEB)

Acceptance Testing of the WRAP 1 Plant Control System Hardware will be conducted throughout the construction of WRAP I with the final testing on the Process Area hardware being completed in November 1996. The hardware tests will be broken out by the following functional areas; Local Control Units, Operator Control Stations in the WRAP Control Room, DMS Server, PCS Server, Operator Interface Units, printers, DNS terminals, WRAP Local Area Network/Communications, and bar code equipment. This document will contain completed copies of each of the hardware tests along with the applicable test logs and completed test exception reports.

1997-02-14

411

VGB guideline, instructions for the procurement of steam turbine plants. Benefits for contractor and client; VGB-Richtlinie, Anleitung zur Beschaffung von Dampfturbinenanlagen. Nutzen fuer Besteller und Auftragnehmer  

Energy Technology Data Exchange (ETDEWEB)

The establishment of the domestic market in Europe requires rules for the assignment of orders, with which a standardization of the rules of competition can be achieved and with which a discrimination of individual bidders can be prevented. Clients and contractors of power station equipments equally are affected by the definitions for the assignment of orders. The contribution under consideration is a regulation for the procurement of steam turbine systems. It is a supplement of the European standard DIN EN 45510:1998. The regulation integrates the former terms of delivery of association of the electricity industry (VDEW) for steam turbines as well as the collection and evaluation of a multiplicity of experiences of the VGB regulations.

2008-07-01

412

Updating of the program for simulation of Darlington shutdown and regulation systems. Research report No. INFO-0309  

Energy Technology Data Exchange (ETDEWEB)

Description of the current status of the developments of a simulation of the Darlington Nuclear Generating Station shutdown and regulating systems, DARSIM. The DARSIM program simulates the spatial neutron dynamics, the regulations of the reactor power, and shutdown system 1 and shutdown system 2 software. The DARSIM program operates in the interactive simulation (INSIM) program environment. DARSIM was installed on the APOLLO computer at the Atomic Energy Control Board (AECB) and a version for an IBM-PC was also provided for the exclusive use of the AECB. Shutdown system software was updated to incorporate the latest revisions in the functional specifications. Additional developments were provided to assist in the use and interpretation of the DARSIM results.

1988-01-01

413

The estimation of lifetime distribution of Alloy 800 steam generator tubing  

Energy Technology Data Exchange (ETDEWEB)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors worldwide and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under appropriate operating conditions. In planning refurbishment of nuclear plants stations, a key concern is the longevity of existing SGs up to the 60-year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and refines its estimation based on data specific to CANDU operating conditions. The paper presents a more advanced Bayesian probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of degradation on reliability of SG tubing.

2009-10-15

414

The estimation of lifetime distribution of Alloy 800 steam generator tubing  

International Nuclear Information System (INIS)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors worldwide and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under appropriate operating conditions. In planning refurbishment of nuclear plants stations, a key concern is the longevity of existing SGs up to the 60-year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and refines its estimation based on data specific to CANDU operating conditions. The paper presents a more advanced Bayesian probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of degradation on reliability of SG tubing.

2009-10-01

415

The Station of Alicante is the Centre of the World.Wars at the Borders and Peace in the Market along the North African Routes to Europe  

British Library Electronic Table of Contents (United Kingdom)

Taking the port city of Alicante the author outlines how numerous crossroads connect the northern and southern shores of the Mediterranean. Along the arc of Euro-Mediterranean trading centres lies the European continent as a whole, extending eastwards to the republics emerging from the disintegration of the Soviet Empire, and in the south to Francophone and Muslim Africa. This arc of trading towns includes Istanbul, Dubai, Naples, Antwerp, Hamburg, Marseilles and Alicante. The author traces the movements of individuals pursuing "suitcase trade" performed by means of face-to-face links, word of mouth, and verbal agreements. The author then traces this vast "choreographed movement" that originates from Europe's borders, and suggests that although reasons other than trade influence mobility a...

2007-01-01

416

The NIST/NRL free-electron laser facility  

International Nuclear Information System (INIS)

A free-electron laser (FEL) user facility is discussed. The FEL, which will be operated as an oscillator, will be driven by the electron beam of the racetrack microtron (RTM) that is nearing completion. Variation of the electron kinetic energy from 17 MeV to 185 MeV will permit the FEL wavelength to be tuned from 200 nm to 10 #mu#m. Performance will be enhanced by the high brightness, low energy spread, and continuous pulse nature of the RTM electron beam. The authors are designing a new injector to increase the peak current of the RTM. A 3.6-m undulator is under construction, and the 9-m optical cavity is under design. The FEL will emit a continuous train of 3-ps pulses at 66 MHz with an average power of 10--200 W, depending on the wavelength, and a peak power of up to several hundred kW. An experimental area is being prepared with up to five stations for research using the FEL beam.

1989-04-24

417

The Authenticated Tracking and Monitoring System (ATMS) concept  

Energy Technology Data Exchange (ETDEWEB)

The Authenticated Tracking and Monitoring System (ATMS) has been designed to address the need for global monitoring of the status and location of proliferation-sensitive items. Conceived to utilize the proposed Global Verification and Location System (GVLS) satellite link, ATMS could use the existing International Maritime Satellite commercial communication system until GVLS is operational. The ATMS concept uses sensor packs to monitor items and environmental conditions, collects a variety of events data through a sensor processing unit, and transmits the data to a satellite, which then sends data to ground stations. Authentication and encryption algorithms will be used to secure the data. A typical ATMS application would be to track and monitor the safety and security of a number of items in transit along a scheduled shipping route. This paper also discusses a possible proof-of-concept system demonstration.

1993-08-01

418

Temperature problems in mine rescue  

Energy Technology Data Exchange (ETDEWEB)

Describes temperature and humidity sensing devices used in mine rescue operations. Chemical indicators use chemical substances that melt at predetermined temperatures and display the actual temperature in the range of 40-50 C. Electronic temperature monitoring devices release acoustic signals as soon as a temperature of 40 or 45 C has been exceeded. A more recent piece of equipment combines the ULR rescue communication set with remote temperature sensing. A digital meter that measures temperature and humidity in the range of -100 to +200 C and 3 to 98% respectively has also been developed. The Central Mine Rescue Station in Bytom, Poland has developed equipment that permits body temperature and pulse rate of a rescuer to be measured and transmitted by radio over a distance of up to 50 m. Safe threshold values can be set for each individual rescuer.

1990-08-01

419

Survey of the marine benthic infauna collected from the United States radioactive waste disposal sites off the Farallon Islands, California. Final report  

International Nuclear Information System (INIS)

Benthic biological samples were taken in 1977 from the vicinity of the Farallon Islands radioactive waste disposal sites for characterization of the infaunal macroinvertebrates and foraminifera. A total of 120 invertebrate species were collected, of which 75 species (63 percent) were polychaetes. Forty-three of these polychaete species have not previously been reported from depths greater than 1000m. A total of 1044 macroinvertebrate specimens were collected of which 54 percent were polychates. Only the nematods were present at all six benthic stations, but the community structure was dominated by the polychaetes Tauberia gracilis, Allia pulchra, Chaetozone setosa, and Cossura candida. Living and dead foraminifera were reported. The possible role of polychaetes in bioturbation and in the marine food chain is briefly discussed with respect to the various polychaete feeding mechanisms.

420

Study on tritium activity build-up in moderator and primary heat transport systems in 540 MWe reactor  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by Deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on Tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-3 and 4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)

2006-11-13

421

Study on tritium activity build-up in moderator and primary heat transport (PHT) systems in 540 MWe reactor  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)

2005-11-23

422

Study of seasonwise variations in the environmental gamma dose rates in Tarapur emergency planning zone (EPZ)  

International Nuclear Information System (INIS)

During the normal operation of a Nuclear Power Plant (NPP), radioactive releases into the atmosphere will be in small quantities. During major accidental situations, though the probability is extremely small, there may be significant release of radioactivity to the environment through the stack or at ground level. To study the external radiation exposure, if any, to the members of public due to releases during the normal operation of a nuclear power plant (NPP) and also to meet the requirement of emergency preparedness for the NPP site, continuous recording and analysis of environmental dose rate data is essential. This paper presents analysis of the gamma dose rates recorded by the Environmental Dose Logging Systems (EDLS) installed around the site during the last six years in the Emergency Planning Zone (EPZ) of Tarapur Atomic Power Station (TAPS). (author)

2005-11-23

423

Stratigraphic and geochemical evidence for industrial pollutants in alpine and subalpine soils of the Wind River Mountains, western Wyoming, USA  

International Nuclear Information System (INIS)

A stratigraphic and geochemical study of alpine soils, which formed in later Pleistocene (late glacial) and Neoglacial deposits in the Wind River Mountains of western Wyoming, indicates that these soils are affected by air-fall in flux of inorganic pollutants. Arsenic, bromine and antimony appear to have been deposited in surface soils by incorporation of aeolian materials which were presumably transported by winds from industrial sources, including coal-burning operations. As vanadium was not found in surface soils at concentrations above site-specific background levels, oil-fired energy generating stations were not found to be significant sources of surface soil pollution in the region. Acid-rain effects were not observed in the soils. (author) 32 refs.; 2 figs.; 3 tabs.

1991-01-01

424

Steam turbines. A simulation model for nozzle group control; Dampfturbinen. Ein Simulationsmodell zur Duesengruppenregelung  

Energy Technology Data Exchange (ETDEWEB)

So far, publications in turbomachinery engineering have tended to neglect the description of control systems and strategies which could be converted into practical guidelines for turbine operation. The contribution describes the power station turbine as a basis for modelling the control stage. The solutions will serve as a basis for further type-specific investigations of the problem. [German] Eine vornehmlich regelungstechnisch ausgerichtete Beschreibung des thermodynamisch-mechanischen Wirkungsgeschehens im Bereich der Regelstufe von Dampfturbinen sowie deren Umsetzung in schluessige, betriebsrelevante Aussagen fehlen bislang in der Turbomaschinenliteratur. Im Beitrag werden am Beispiel der Kraftwerksturbine die Grundlagen fuer eine modelltechnische Nachbildung der Regelstufe entwickelt. Die Loesungen dienen als Ausgangsbasis fuer weitere typenspezifische Bearbeitungen dieses Problems. (orig.)

2000-07-01

425

Statistical analyses of coads wind data in coastal regions of the United States  

Energy Technology Data Exchange (ETDEWEB)

In the study, wind data from the Comprehensive Ocean-Atmosphere Data Set (COADS) are used to determine atmospheric circulation changes which are empirically associated with the air temperature changes. Some understanding of the natural processes which produce climate change is anticipated from the study of these associations. Systematic changes of wind in US coastal regions with periods of climate warming and cooling suggest circulation changes, in addition to carbon dioxide-controlled radiation effects, could produce the climate changes indicated by air temperature. A statistical procedure for analyses of COADS was used to determine decade-period vector wind-field differences from the COADS record period. The statistical procedure for these analyses is explained and the wind differences are compared to summaries of mid-Atlantic coast island-station observations.

1992-08-01

426

Source and profile of paralytic shellfish poisoning toxins in shellfish in Daya Bay, South China Sea  

British Library Electronic Table of Contents (United Kingdom)

Changes in cell density and cyst flux of Alexandrium tamarense, paralytic shellfish poisoning (PSP) toxin contents in shellfishes, and environmental parameters were measured in two stations in Daya Bay, South China Sea from March 2005 to July 2006. Vegetative cells of A. tamarense occurred sporadically; however, they presented abundantly during the winter months. Meanwhile, cyst flux reached its maximum level just following the peak abundance of motile cells. The PSP contents in shellfish were generally low, but higher in winter with the maximum of 14,015 @mg STX equiv./kg. The majority of toxins were found in digestive glands, with a maximum of 66,227 @mg STX equiv./kg. There were significant positive relationships between toxin level and vegetative cell density and cyst flux. This indica...

2011-01-01

427

Some geotechnical aspects of the Hyogo-ken Nanbu (Kobe) earthquake of January 17, 1995  

Energy Technology Data Exchange (ETDEWEB)

A geological and geotechnical framework was provided in order to facilitate understanding of the damage to structures resulting from soil conditions during the earthquake of January 17, 1995 at Hyogo-ken Nanbu (Kobe), Japan. Special attention was paid to the large scale failures of the quay walls in the port of Kobe, resulting from liquefaction. The performance of structures in improved and unimproved ground were compared. It was observed that locations with some previous site improvements through densification behaved satisfactorily, despite unanticipated high levels of ground motion. Soil-structure interaction problems, such as pile foundations, bridge piers, lifelines, and an underground subway station were also described. Reference was made to the significance of these failures for the seismic design in the Fraser Delta in British Columbia in view of the area`s proneness to liquefaction during a major earthquake. 31 refs., 5 tabs., 45 figs.

1996-06-01

428

SIMS imaging studies of the corrosion of alloy 800 and alloy 600 surfaces under secondary side boiler conditions  

Energy Technology Data Exchange (ETDEWEB)

The nickel-rich superalloys Alloy 600 and Alloy 800 have been corroded in mildly alkaline deuterated aqueous conditions typical of secondary coolant circuits in a nuclear power station. The oxide films and substrates of these alloys have been analysed by imaging SIMS depth profiling, which makes it possible to describe elemental distribution in all three dimensions. The measurement of the distribution of the secondary ions NiO[sup -], FeO[sup -] and CrO[sup -] appears useful for detailing the behaviour of nickel, iron and chromium within oxidized phases. The measurement of D[sup -] distribution outlines the extent of oxide hydration. For Alloy 800, evidence of sodium migration into the grain boundaries of the alloy substrate is found. For Alloy 600, no grain boundary sodium ingress can be identified under comparable corrosion conditions. (author).

1992-08-01

429

SIMS imaging studies of the corrosion of alloy 800 and alloy 600 surfaces under secondary side boiler conditions  

International Nuclear Information System (INIS)

The nickel-rich superalloys Alloy 600 and Alloy 800 have been corroded in mildly alkaline deuterated aqueous conditions typical of secondary coolant circuits in a nuclear power station. The oxide films and substrates of these alloys have been analysed by imaging SIMS depth profiling, which makes it possible to describe elemental distribution in all three dimensions. The measurement of the distribution of the secondary ions NiO"-, FeO"- and CrO"- appears useful for detailing the behaviour of nickel, iron and chromium within oxidized phases. The measurement of D"- distribution outlines the extent of oxide hydration. For Alloy 800, evidence of sodium migration into the grain boundaries of the alloy substrate is found. For Alloy 600, no grain boundary sodium ingress can be identified under comparable corrosion conditions. (author).

430

Retrofitting bus fleet for natural gas operation. Session 2, 4th ATIG symposium; Esempio di flotta automezzi di una societa` trasformati per alimentazione a gas naturale  

Energy Technology Data Exchange (ETDEWEB)

Buses, operating within a Florence (Italy) municipal transportation system, and equipped with Otto cycle engines, were selected for retrofitting taking into account the suitability of each vehicle`s specific routing and service requirements. Cost benefit analyses indicated that it wouldn`t be economically feasible to retrofit buses equipped with diesel engines. A computerized refuelling system was set up at the fleet`s central service station which was hooked up to the natural gas utility`s supply line. This paper tables the cost benefit analysis data comparing gasoline and methane operation and reflecting the cost savings which are expected to be accrued through this methanization program over a span of 14 years.

1992-12-31

431

Retrieval of chlorophyll a concentration from a fluorescence enveloped area using hyperspectral data  

British Library Electronic Table of Contents (United Kingdom)

It is acknowledged that fluorescence line height (FLH) algorithms are still hampered by the uncertainty of fluorescence peak position. The fluorescence peak moves to longer wavelengths with the increase of chlorophyll a concentration. In this article, the fluorescence enveloped area (FEA), which integrates the fluorescence height and the fluorescence peak position, was used to estimate the chlorophyll a concentration in the coastal waters of the Pearl River Estuary. The FEA algorithm was developed from in situ data of chlorophyll a concentration, total suspended matter (TSM) concentration and above-water remote sensing reflectance, which were collected at 37 sampling stations in the Pearl River Estuary during two cruises. The results showed that the FEA algorithm made a better estimation o...

2011-01-01

432

Results from a Prototype Chicane-Based Energy Spectrometer for a Linear Collider  

Energy Technology Data Exchange (ETDEWEB)

The International Linear Collider (ILC) and other proposed high energy e{sup +}e{sup -} machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 10{sup -4}. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006-2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5 {center_dot} 10{sup -4} was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving its performance.

2011-02-28

433

Relationship between the lability of sediment-bound metals (Cd, Cu, Zn) and their bioaccumulation in benthic invertebrates  

British Library Electronic Table of Contents (United Kingdom)

The present study has investigated metal contamination at nine sites (10 sampling stations) from the English Channel to the Mediterranean Sea, including low level and highly contaminated sediments. Both total and labile concentrations of metals were determined in superficial sediments. The influence of different pHs was tested and metal lability at pHs encountered in the gut of invertebrates (the ragworm Nereis diversicolor, the blue mussel Mytilus edulis, the Japanese oyster Crassostrea gigas) was compared with the distribution of metals in various operationally defined geochemical fractions. Cd showed the highest lability and Cu the lowest, whereas Zn lability was intermediate. Metal concentrations were determined in bivalves at six sites and in worms at three sites. Cd in living organis...

2007-01-01

434

Reconstructions of archaeological contexts in OpenGl environments; Intelligenza artificiale per i beni culturali e le biblioteche digitali. Atti del Workshop  

Energy Technology Data Exchange (ETDEWEB)

DVR project concerns the creation of a virtual reality OpenGL system for desktop applications in archaeology. The main goal is the creation of a 3D information system using the real time interaction of OpenGL environments. The first case study implemented is the Vettii House, one of the most important and outstanding monuments in Pompei. The virtual reconstruction of these architectural models is based on very detailed photogrammetric surveys and it is connected with information layers and archaeometric data-bases regarding the state of conservation of walls, structures and any type of materials of the monument. A full 3D interface characterizes the system, comprising a high resolution texturing with detailed volumetric and geometric data. Finally, for the future, the project plans to fit the system for scientific and end users through the installation of stations on site.

2001-07-01

435

Radiation Protection Aspects of the Linac Coherent Light Source Front End  

Energy Technology Data Exchange (ETDEWEB)

The Front End Enclosure (FEE) of the Linac Coherent Light Source (LCLS) is a shielding housing located between the electron dump area and the first experimental hutch. The upstream part of the FEE hosts the commissioning diagnostics for the FEL beam. In the downstream part of the FEE, two sets of grazing incidence mirror and several collimators are used to direct the beam to one of the experimental stations and reduce the bremsstrahlung background and the hard component of the spontaneous radiation spectrum. This paper addresses the beam loss assumptions and radiation sources entering the FEE used for the design of the FEE shielding using the Monte-Carlo code FLUKA. The beam containment system prevents abnormal levels of radiations inside the FEE and ensures that the beam remains in its intended path is also described.

2010-08-26

436

R and D on high efficiency CO{sub 2} separation processes for enhanced oil recovery at the University of Regina  

Energy Technology Data Exchange (ETDEWEB)

Research facilities and personnel in high efficiency separation processes for carbon dioxide removal from industrial sources, such as fossil fuel fired power stations, goal gasification plants, and hydrogen production units for enhanced oil recovery applications at the University of Regina were described. A brief summary of current projects, such as the determination of CO{sub 2} absorption capacity of sterically hindered amines, the formulation of high CO{sub 2} absorption capacity solvents, the search for high performance absorbers and regenerators, studies on material corrosion, and optimization and cost studies of co-production of CO{sub 2} and electricity, was also provided.

1997-02-01

437

Proposal of the research complex for the neutron science (The first plan)  

Energy Technology Data Exchange (ETDEWEB)

Japan Atomic Energy Research Institute (JAERI) is developing the world`s strongest spallation neutron source using high power proton accelerator and promoting a neutron science project for comprehensive studies on basic science and nuclear transmutation of high-level radioactive nuclide from nuclear power stations. For this purpose, JAERI organized the Special Taskforce for Neutron Science and OMEGA Project in April 1996 and reorganized it to Center for Neutron Science in April 1997. During this period, various research plans using the spallation neutron source are proposed and facilities necessary for research are studied by mainly research groups of JAERI. This report describes research plans and results of the preliminary conceptual design study on proposed facilities plan. (author)

1999-03-01

438

Problems of air pollution monitoring  

Energy Technology Data Exchange (ETDEWEB)

The development of the monitoring network for background measurements of air pollution in the USSR is noted. The use of paired stations, to aid in locating permanent sites as well as for determining the local component of background air pollution, is described. Thermoelectric actionometers with five glass filters are used to measure Shupp's turbidity coefficient for estimating extinction of solar radiation due to aerosols. Sampling and chemical analysis of precipitation uses methods developed during the International Geophysical Year. An intercomparison of meteorological instruments was carried out in the USSR in 1973 and 1978. The most stable actinometer was the Linke-Foisner device. Chemical analyses of precipitation made since 1958 in the USSR show increases in air pollution levels only in particular areas.

1980-01-01

439

Predicting urban forest growth and its impact on residential landscape water demand in a semiarid urban environment  

British Library Electronic Table of Contents (United Kingdom)

We present an innovative approach to estimating residential irrigation water demand for a large metropolitan area using GIS data, weather station data, and a water budget modeling approach commonly used by plant scientists and landscape management professionals. An important question addressed by our study is how a growing urban forest affects the overall irrigation water demand of a semiarid metropolitan area. To estimate the amount of water required by residential landscaping, we consider water demand to be a function of the areal extent of residential landscaping (i.e. tree/shrub or turf grass), the water-loss rate for different landscaping types, the efficiency with which the landscape is irrigated, and local climatic factors (i.e. reference evapotranspiration and precipitation). We es...

2011-01-01

440

Pre-test report on international round robin analysis of BARC containment (BARCOM) test model  

International Nuclear Information System (INIS)

BARC has organized an international round robin analysis program to carry out the ultimate load capacity assessment of BARC containment (BARCOM) test model. The test model located in BARC facilities Tarapur, is a 1:4 scale representation of 540 MWe pressurized heavy water reactor (PHWR) pre-stressed concrete inner containment structure of Tarapur Atomic Power Station (TAPS) unit 3 and 4. The features of the BARCOM test model and the constitutive data for the pre-test analysis along with the comparison of the results submitted by various participants are described in this pre-test report of the round robin analysis of BARCOM test model

2009-01-01

441

Ozone and NOy in the Milan plume: the episode of June 19-21, 1998  

International Nuclear Information System (INIS)

Nitrogen oxides (NOx=NO+NO2), total reactive nitrogen NOy, ozone (O_3), JNO_2 and volatile organic compounds (VOC) were measured for 10 weeks during spring and summer 1998 in the highly polluted Milan agglomeration. The concentrations during the episode of June 19 to 21 are analysed. During this period ozone peaks at 160 ppb, NOy at 36 ppb. The high NOz/NOy-ratio in the afternoon indicates aged air masses reaching the station. We refer to NOz as the difference between NOy and NOx. It stands for NOx consumed during the photochemical aging of the air mass. Depending on the origin of the air mass the limitation of the ozone production shifts between VOC- and NOx-sensitivity. (Author)

442

New sealant for nuclear power station premises of emergency location  

International Nuclear Information System (INIS)

When operating a nuclear power plant the necessity arise to eliminate various defects of building constructions, to seal joints and transitional elements. The authors present data concerning the production of a sealing composition made of epoxy resin and used for NPP premises of emergency location. Analytical relations are presented between the properties of the composition (adhesion strength, water absorption and others) and its structure. Physical, mechanical and thermal properties and structural peculiarities are determined in the process of interaction between the filling and binding agents. The composition sustains sealing properties under environmental conditions at he presence of an air - vapour mixture with 160 degrees C"o temperature and 0.3 MPa surplus pressure. (author).

443

Neutron intensity measurements of BWR spent fuels  

International Nuclear Information System (INIS)

A neutron scanning device was developed in order to obtain accurate neutron intensities of high burn-up BWR fuels. This scanning device was calibrated with a "2"5"2Cf source and used to measure axial distributions of neutron intensities of BWR fuels with various enrichments (2.0%-3.4%) irradiated up to 60 GWd/tU at Fukushima Daini Nuclear Power Station Unit 2(2F-2). The measured neutron intensities were approximated well with power law interpolations on the calculated burn-up values. The neutron intensities calculated by the ORIGEN2-86 code showed good agreements with the measured ones within 20%. (author)

2000-03-01

444

Mean precipitation estimation, rain gauge network evaluation and quantification of the hydrologic balance in the River Quito basin in Choco, state of Colombia  

International Nuclear Information System (INIS)

In this work the calculation of the average precipitation in the Quito River basin, state of Choco, Colombia, is presents through diverse techniques, among which are those suggested by Thiessen and those based on the isohyets analysis, in order to select the one appropriate to quantification of rainwater available to the basin. Also included is an estimation of the error with which the average precipitation in the zone studied is fraught when measured, by means of the methodology proposed by Gandin (1970) and Kagan (WMO, 1966), which at the same time allows to evaluate the representativeness of each one of the stations that make up the rain gauge network in the area. The study concludes with a calculation of the hydrologic balance for the Quito river basin based on the pilot procedure suggested in the UNESCO publication on the study of the South America hydrologic balance, from which the great contribution of rainfall to a greatly enhanced run-off may be ...

2006-03-01

445

Interference Mitigation Using Uplink Power Control for Two-Tier Femtocell Networks  

CERN Document Server

This paper proposes two interference mitigation strategies that adjust the maximum transmit power of femtocell users to suppress the cross-tier interference at a macrocell base station (BS). The open-loop and the closed-loop control suppress the cross-tier interference less than a fixed threshold and an adaptive threshold based on the noise and interference (NI) level at the macrocell BS, respectively. Simulation results show that both schemes effectively compensate the uplink throughput degradation of the macrocell BS due to the cross-tier interference and that the closed-loop control provides better femtocell throughput than the open-loop control at a minimal cost of macrocell throughput.

2009-01-01

446

Induction motor for tunnel exhauster; Tunnel haifukiyo yudo dendoki  

Energy Technology Data Exchange (ETDEWEB)

A totally-enclosed, fan-cooled, rib-cooled type induction motor is adopted for an exhauster which is to be installed in a ventilation station for dust catcher in a tunnel. It has the highest capacity in Japan for the above purpose, and is provided with a cooling fan inside to recirculate cooled air, thereby improving cooling efficiency and reducing size and weight. Three-row combined angular ball bearings are used as the thrust bearings, and grease lubrication system is adopted to simplify the inspection/maintenance works. It is to be delivered to Japan Highway Public Corporation's Shizuoka Construction Bureau, Yaizu site office. Its electric specifications are 455 kW, 440 V, 890 A and 510 rpm, and its mechanical specifications are thrust load: 16 kN and impeller load: 7.2 kN. (translated by NEDO)

2000-01-10

447

Improving performance and availability by means of steam turbine diagnoses; Steigerung von Wirkungsgraden und Verfuegbarkeit durch Dampfturbinen-Diagnose  

Energy Technology Data Exchange (ETDEWEB)

Diagnostic systems make it possible to recognize incipient faults in good time and help to increase the availability of power stations. The thermal efficiency and the effective terminal output are didicated by a number of influences. Deviations from the expected status can be identified via continuous recording of the operating parameters and calculation of derived data. An improved efficiency and economical load distribution lead to considerable cost savings. (orig.) [Deutsch] Die Verarbeitung von Messwerten und Signalen ermoeglicht eine umfassende Beurteilung des Anlagenzustandes und die Erkennung sich anbahnender Veraenderungen. Stoerungen, Schaeden oder eine unwirtschaftliche Betriebsweise koennen fruehzeitig erkannt werden. Erhoehte Verfuegbarkeit, geringerer Brennstoffverbrauch und optimierte Lastaufteilung bringen Kostenvorteile. (orig.)

1996-12-31

448

Implantation of a essential diesel generator CN Vandellos II and fifth emergency diesel generator Asco  

International Nuclear Information System (INIS)

This article describes the project for the installation of an additional emergency diesel generator in both Asco and Vandellos NPPs. The basic objectives of this project are to improve the availability of the emergency generation system, in order to provide greater ability to address potential contingencies, and also to increase the flexibility of the preventive periodic maintenance of the emergency diesel generators. This maintenance, that is currently a milestone of the critical path of the refueling outage, will be performed on-line. The new diesel generator will be sized to support all the loads considered in the safety case and also the consumption of its own auxiliary systems, and will be tested for operability assessment on the same periodical basis than the existing ones. The solution adopted will also permit that the N diesel generator may be connected to any bus bar class 1E in a station black-out scenario. (Author)

449

High efficiency by advanced power plant engineering. Siemens PG: Best solutions for high-tech steam turbines; Hoehere Wirkungsgrade durch moderne Kraftwerkstechnik. Siemens PG: Best solutions fuer High-tech-Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

A consequent use of computers and standardized components enables high efficiency for steam turbines while produced at lower manufacturing cost as shown here in the Muehlheim company of Siemens Power Generation, where steam turbines are produced for new stations and retrofitted elder power plants. [German] Auch eine ueber hundert Jahre alte Technik bietet Raum fuer Innovationen: Konsequenter Computereinsatz und standardisierte Baureihen ermoeglichen bei Dampfturbinen hohe Wirkungsgrade bei relativ niedrigen Fertigungskosten - umgesetzt im Werk Muelheim der Siemens Power Generation, wo Dampfturbinen fuer Neuanlagen und zum Modernisieren bestehender Kraftwerke entstehen. (orig.)

2002-07-01

450

Geochemical modelling of acidification and recovery in forest soils and runoff waters  

Energy Technology Data Exchange (ETDEWEB)

The Model of Acidification of Groundwaters in Catchments (MAGIC) was used to simulate the impact of acidifying deposition and future recovery at the Gaardsjoen Covered Catchment Experiment, at a number of hypothetical stations defined by statistical variation of the Gaardsjoen data and at 20 forest monitoring sites in Southern Sweden. For the future predictions a decrease of sulphur deposition of more than 70% was assumed. This assumption is based on a full implementation of the agreements made under the second sulphur protocol from 1994. The modelled impact of reduced deposition on the soils and on the runoff waters was discussed. To complement the discussion on long-term trends in future run-off chemistry, data from Gaardsjoen has been used to asses the risk for short-term acid runoff episodes 26 refs, 23 figs, 7 tabs

1999-01-01

451

Genetic diversity among Angus, American Brahman, Senepol and Romosinuano cattle breeds:  

British Library Electronic Table of Contents (United Kingdom)

Summary The objective of this study was to quantify the genetic diversity among breeds under evaluation for tropical adaptability traits that affect the performance of beef cattle at the USDA/ARS SubTropical Agricultural Research Station (STARS) near Brooksville, FL, USA. Twenty-six microsatellite loci were used to estimate parameters of genetic diversity among the breeds American Brahman, Angus, Senepol and Romosinuano; the latter was comprised of two distinct bloodlines (Costa Rican and Venezuelan). Genotypes of 47 animals from each of these STARS herds were analysed for genetic diversity and genetic distance. Using two methods, the greatest genetic distance was detected between the Costa Rican line of Romosinuano and the Senepol. Gene diversity ranged between 0.64 (Costa Rican line of R...

2007-01-01

452

Generation and relaxation of microstrains in GaN nanocrystals under extreme pressures  

International Nuclear Information System (INIS)

Nanocrystalline powders of GaN with grain sizes ranging from 2 to 30 nm were examined under high external pressures by in situ diffraction techniques in a diamond anvil cell at DESY (HASYLAB, Station F3). The experiments on densification of pure powders under high pressure were performed without a pressure medium. The mechanism of generation and relaxation of internal strains and their distribution in nanoparticles was deduced from Bragg reflections recorded in situ under high pressures at room temperature. The microstrain was calculated from the full-width at half-maximum (FWHM) values of the Bragg lines. It was found that microstrains in GaN crystallites are generated and subsequently relaxed by two mechanisms: generation of stacking faults and change of the size and shape of the grains occurring under external stress. (author)

2001-09-23

453

Ford's CNG vehicle research  

Energy Technology Data Exchange (ETDEWEB)

Several natural gas vehicles have been built as part of Ford's Alternative Fuel Demonstration Fleet. Two basic methods, compressed gas (CNG), and liquified gas (LNG) were used. Heat transfer danger and the expense and special training needed for LNG refueling are cited. CNG in a dual-fuel engine was demonstrated first. The overall results were unsatisfactory. A single fuel LNG vehicle was then demonstrated. Four other demonstrations, testing different tank weights and engine sizes, lead to the conclusion that single fuel vehicles optimized for CNG use provide better fuel efficiency than dual-fuel vehicles. Lack of public refueling stations confines use to fleet operations.

1983-06-01

454

Experimental investigation of wall static pressure fluctuations in parallel boiling flow  

International Nuclear Information System (INIS)

Measurements of the statistical characteristics of channel wall static pressure fluctuations in parallel one-component boiling flow are reported. The measurements span a wide range of local subcooling and vapor volume fraction, and correspond to flow regimes ranging from highly subcooled bubbly to saturated slug-annular. Vapor volume fraction measurements at the pressure measurement station are also reported in conjunction with visual observation of the flow structure. Variation of static pressure fluctuation intensity and spectral content with local thermal-hydraulic condition is demonstrated. Finally, it is suggested that diagnosis of local two-phase flow regime on the basis of (i) statistical characteristics of the pressure data, and (ii) time trace of pressure signal, may be possible. 15 refs.

1980-01-01

455

Ethernet networks technology in electrical substations  

Energy Technology Data Exchange (ETDEWEB)

In both office and home environments, Ethernet represents the dominant networking technology in use. Ethernet is low cost and the networks are fairly understood by users. The author began by explaining the physical and data link layers of Ethernet, then touched on fibre-optic cables. The industrial protocols were discussed, followed by Ethernet network topology. The environmental robustness of Ethernet networks was reviewed, with a word of caution from the author, advising to properly evaluate whether Ethernet represents a mission-critical component of the substation, as substation control houses are not environmentally controlled spaces, often minimally heated and no cooling. Engineering access to station Integrated Electric Drives (IEDs). By properly connecting Ethernet networks, it is possible to access relays in the substations from desktop engineering workstations in the central office. Network security issues must be addressed to prevent unauthorized access ...

2002-07-01

456

Estimating pressurized water reactor decommissioning costs: A user`s manual for the PWR Cost Estimating Computer Program (CECP) software. Draft report for comment  

Energy Technology Data Exchange (ETDEWEB)

With the issuance of the Decommissioning Rule (July 27, 1988), nuclear power plant licensees are required to submit to the US Regulatory Commission (NRC) for review, decommissioning plans and cost estimates. This user`s manual and the accompanying Cost Estimating Computer Program (CECP) software provide a cost-calculating methodology to the NRC staff that will assist them in assessing the adequacy of the licensee submittals. The CECP, designed to be used on a personnel computer, provides estimates for the cost of decommissioning PWR plant stations to the point of license termination. Such cost estimates include component, piping, and equipment removal costs; packaging costs; decontamination costs; transportation costs; burial costs; and manpower costs. In addition to costs, the CECP also calculates burial volumes, person-hours, crew-hours, and exposure person-hours associated with decommissioning.

1993-10-01

457

Energy threat to valuable land  

Energy Technology Data Exchange (ETDEWEB)

A negative public reaction is expected to oppose plans of the British energy industry to take valuable sites for industrial and commercial projects on the ground that government demand forecasts are too high and that they downplay conservation. The United Kingdom (UK) Department of Energy points out that public inquiry always accompanies energy installations and defends the projections made by producers even though each study emphasizes the demand for its own form of energy. At issue are plans to open 150 opencast coal mines a year to compensate for diminishing oil and gas supplies, onshore drilling by oil and gas exploration teams on nearly 50,000 km/sup 2/, and sites required for onshore pipelines, synthetic natural gas facilities, pumped storage plants, and nuclear power stations and waste management. The sites under discussion raise aesthetic and ecological concerns. (DCK)

1982-03-11

458

Energy savings opportunity survey. US Army Field Station Kunia, Oahu, Hawaii. Final report  

Science.gov (United States)

This Energy Savings Opportunity Survey (ESOS) is to identify Energy Conservation Opportunities (ECO`s) which are practical and economical for the reduction of energy consumption in accordance with the Army Facilities Energy Plan. The work to be performed under this project includes: (A) Coordinating with the on-going and proposed related projects. (B) Conducting a limited site survey required to identify applicable ECO`s and obtaining necessary data to evaluate the ECO`s. (C) Evaluating applicable ECO`s to determine their feasibility in accordance with current criteria. (D) Preparing programming and implementation documents for the recommended ECO`s. and (E) Preparing a comprehensive report to present the work performed including energy analysis, the results, and recommendations.

1989-06-01

459

Electric utility engineer`s FGD manual -- Volume 1: FGD process design. Final report  

Energy Technology Data Exchange (ETDEWEB)

Part 1 of the Electric Utility Engineer`s Flue Gas Desulfurization (FGD) Manual emphasizes the chemical and physical processes that form the basis for design and operation of lime- and limestone-based FGD systems applied to coal- or oil-fired steam electric generating stations. The objectives of Part 1 are: to provide a description of the chemical and physical design basis for lime- and limestone-based wet FGD systems; to identify and discuss the various process design parameters and process options that must be considered in developing a specification for a new FGD system; and to provide utility engineers with process knowledge useful for operating and optimizing a lime- or limestone-based wet FGD system.

1996-03-04

460

Economic assessment of combined cycle gas turbines in Australia Some effects of microeconomic reform and technological change  

International Nuclear Information System (INIS)

Australian electricity markets and natural gas markets are undergoing rapid reform. Choosing among electricity generation modes is a key issue. Such choices are affected by expectations about the future structure of these markets and future technologies, and how they affect costs and emissions. In the research reported in this paper, the MARKAL model of the Australian energy system is used to evaluate the competitive position of natural gas fired combined cycle gas turbines (CCGTs) in the energy sector as a whole. Competing in the sector are large-scale electricity generation technologies such as refurbished existing coal fired stations and advanced forms of coal fired generation. The modelling incorporates new data on electricity supply technologies and options.

2003-02-01

461

Downscaling of GCM forecasts to streamflow over Scandinavia  

DEFF Research Database (Denmark)

A seasonal forecasting technique to produce probabilistic and deterministic streamflow forecasts for 23 basins in Norway and northern Sweden is developed in this work. Large scale circulation and moisture fields, forecasted by the ECHAM4.5 model 4 months in advance, are used to forecast spring flows. The technique includes model output statistics (MOS) based on a non-linear Neural Network (NN) approach. Results show that streamflow forecasts from Global Circulation Model (GCM) predictions, for the Scandinavia region are viable and highest skill values were found for basins located in south-western Norway. The physical interpretation of the forecasting skill is that stations close to the Norwegian coast are directly exposed to prevailing winds from the Atlantic ocean, which constitute the principal source of predictive information from the atmosphere on the seasonal timescale.

2008-01-01

462

Development of calibration facility for radiation protection monitoring instruments  

International Nuclear Information System (INIS)

Exposure control at the operating Nuclear Power Station is a major concern. The challenging task of meeting the International standards in the field of radiation protection is the calibration of the radiation monitoring instruments and interpretation of personnel and area monitoring results. Correct interpretation is based on accurate calibration of radiation measuring instruments. The reliability and accuracy of the measurements are also partly based on the procedures applied in calibration. Inadequate calibration can cause large errors in dose estimation in complete dose rate range and energy range. Semiautomatic calibration facility established at TAPS 3 and 4 for radiation monitoring instruments. Objective of calibration facility is (a) Ensure instruments are working properly (b) calibration adjustment and (c) in case without calibration adjustment to reveal the error involved. The calibration facility and calibration techniques established at TAPS 3 and 4 are ...

2008-11-19

463

Development of barcode system for internal dose monitoring  

International Nuclear Information System (INIS)

In Tarapur Atomic Power Station unit-3 and 4, which is 540 MWe pressurized heavy water reactor, tritium is produced in primary heat transport system and moderator system. Tritium is a major contributor to the internal dose. Internal dose contributes about 30% of the collective dose. Internal dose monitoring and its control are important to control the collective dose. Estimation of internal dose is done by analysis of bioassay samples of radiation workers. In a month, about 7000 bioassay samples are analysed for the internal dose assessment during normal operation, and about 12000 during the biennial shut down of the reactor. To enhance the sample preparation and counting performance, minimize the entry errors and reduce the processing time, barcode based label generation system was developed for the internal dose monitoring. This paper discusses about the use of barcode system in the internal dose monitoring at TAPS 3 and 4. (author)

2008-11-19

464

Development of an advanced power system stabilizer using a strict linearization approach  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a practical design for a power system stabilizer using the differential geometric linearization approach. This stabilizer uses the information at the secondary bus of the step-up transformer as input signals, enabling its application to multi-machine power systems. The stabilizer makes it possible to obtain all necessary information within its own power station without observing an equivalent reactance in other power systems. To evaluate the dynamic performance of this stabilizer, the authors tested it on a multi-machine system model using the computer. The simulation results showed that the stabilizer offered good dynamic performance and robustness compared with conventional power system stabilizers, thus confirming its very effective and practical application in power system stabilization.

1996-05-01

465

Detect and classify faults using neural nets  

Energy Technology Data Exchange (ETDEWEB)

The analysis of transmission line faults is essential to the proper performance of the power system. It is required if protective relays are to take the appropriate action and in monitoring the performance of relays, circuit breakers, and other protective and control elements. The detection and classification of transmission line faults is a fundamental component of such fault analysis. Another application of fault analysis is in software packages for automated analysis of digital fault recorder (DFR) files. Recently, such a package, called DFR Assistant, was developed for substation applications. This program can be installed locally in a substation, in which case it is connected directly to the DFR via a high speed parallel link, or it can be installed at a central station, in which case it can be configured to automatically analyze events coming from all DFRs.

1996-10-01

466

Deep subsurface structure modeling based on microtremor and earthquake observation. Applicability of microtremor array measurements at the Kashiwazaki-Kariwa Nuclear Power Station  

International Nuclear Information System (INIS)

During the 2007 Niigataken Chuetsu-oki earthquake, strong ground motion with the peak acceleration of 680 cm/s/s which was larger than that of the empirical prediction was recorded at the base mat of the No.1 reactor building of Kashiwazaki-Kariwa Nuclear Power Station (NPS). Furthermore, in the Kashiwazaki-Kariwa NPS, over twice difference of 680 vs. 322 cm/s/s of peak acceleration between the No.1 and the No.6 reactor buildings was observed on the base mat. From the results of recent research, it is suggested that the deep sedimentary layers can be one of the important factors to elucidate these phenomena. In this study, at first, the applicability of microtremor array measurements for estimation of deep S-wave velocity structure (#approx#Vs=3 km/s layer) are discussed. Vertical microtremors were observed in three arrays at the Kashiwazaki-Kariwa NPS with the maximum station spacings of 3.04 km, 1.49 km and 0.75 km, respectively. The Rayleigh ...

2010-05-01

467

Conceptual HALT (Hydrate Addition at Low Temperature) scaleup design: Capital and operating costs: Part 5. [Hydrate addition at low temperature for the removal of SO/sub 2/  

Energy Technology Data Exchange (ETDEWEB)

Hydrate addition at low temperature (or the HALT process) is a retrofit option for moderate SO/sub 2/ removal efficiency in coal burning utility plants. This dry FGD process involves injecting calcium based dry hydrate particles into flue gas ducting downstream of the air preheater where the flue gas temperature is typically in the range of 280-325/degree/F. This report is comprised of the conceptual scaleup design of the HALT process to a 180 MW and a 500 MW coal fired utility station followed by detailed capital and operating cost estimates. A cost sensitivity analysis of major process variables for the 500 MW unit is also included. 1 fig.

1988-12-01

468

Comparison of stomach contents and condition of two catfish species living at ambient temperatures and in a heated discharge  

International Nuclear Information System (INIS)

The lower condition factors for two catfish species in water heated by effluents from APCo's Glen Lyn, Virginia plant as compared to control areas probably is not due to lack of food as evidenced by macroinvertebrate sampling and the fact that only 4.3 percent of the catfish stomachs were empty. Results suggested that young-of-the-year channel catfish were nonselectively eating food organisms present at both control and heated stations. The difference between stomach contents of flatheat catfish from the heated site and fauna available at that site indicated that fish were either moving out of the heated area to feed or were selectively feeding on organisms (particularly mayflies) which were in the substrate or drifted into the heated area. Stomach contents of the two species and distribution and abundance of the macroinvertebrate benthos community are detailed.

469

Chalk Point cooling tower project. Volume 2. Cooling tower drift dye tracer experiment, June 16 and 17, 1977. Final report 1 July 1976--30 June 1977  

Science.gov (United States)

A drift dye tracer experiment, using Rhodamine (WT) dye, was conducted on airborne drift from a natural draft cooling tower at PEPCO's Chalk Point, Maryland Power Generating Station. This experiment was designed to separate and identify cooling tower aerosol deposition from other sources and to provide a data base for use in cooling tower salt loading and model validation. Prior to the experiment, laboratory tests showed that Rhodamine (WT) was inexpensive, safe and controllable when used as a drift dye tracer. Positive identification and separation of cooling tower drift can be made among other sources using a dye tracer.

1977-08-01

470

Assessment of the sensitivity and prediction uncertainty of evaporation models applied to Nasser Lake, Egypt  

British Library Electronic Table of Contents (United Kingdom)

SummaryThis paper examines the sensitivity and uncertainty of evaporation estimates from Nasser Lake, south of Egypt using data collected at the floating station Raft, 2km upstream of the Aswan High Dam, and 12 evaporation models. Based on their approach the evaporation models were ranked in five classes, respectively the Bowen ratio energy budget (BREB) approach, three energy-aerodynamic based methods, a mass transfer method, two temperature and five solar radiation-temperature approaches. State dependent parameter models were used to estimate the sensitivity indices of the different evaporation estimation methods at daily and monthly frequencies. A drastic reduction in the cost of the sensitivity analysis was obtained when coupled with efficient sampling methods, producing quasi-Monte Ca...

2010-01-01

471

Assessing potential impacts of climatic change on subalpine forests on the eastern Tibetan Plateau  

British Library Electronic Table of Contents (United Kingdom)

Forest gap models have been used widely in the study of forest dynamics, including predicting long-term succession patterns and assessing the potential impacts of climate change on forest structure and composition. However, little effort is devoted to predict forest dynamics in the high elevation areas, although they have the sensitive response to global climate change. In the present study, based on a modified height-diameter function, we developed a new version (FAREAST-GFSM) of the forest patch model, FAREAST for simulating the changes of subalpine forests. The observed data from the Gongga Mt. Alpine Station were also used to test model precision. With the improved performance of FAREAST-GFSM, we explored the impact of three warming scenarios on subalpine forest on the eastern Tibetan ...

2011-01-01

472

An efficient quantum secure direct communication scheme with authentication  

Science.gov (United States)

In this paper an efficient quantum secure direct communication (QSDC) scheme with authentication is presented, which is based on quantum entanglement and polarized single photons. The present protocol uses Einstein-Podolsky-Rosen (EPR) pairs and polarized single photons in batches. A particle of the EPR pairs is retained in the sender's station, and the other is transmitted forth and back between the sender and the receiver, similar to the ``ping-pong'' QSDC protocol. According to the shared information beforehand, these two kinds of quantum states are mixed and then transmitted via a quantum channel. The EPR pairs are used to transmit secret messages and the polarized single photons used for authentication and eavesdropping check. Consequently, because of the dual contributions of the polarized single photons, no classical information is needed. The intrinsic efficiency and total efficiency are both 1 in this scheme as almost all of the instances are useful and ...

2007-07-01

473

An efficient algorithm for the design of decentralized output feedback power system stabilizer  

Science.gov (United States)

A new algorithm for the design of decentralized output feedback stabilizers for large-scale electric power systems is presented in this paper. In the proposed approach, the generators which are most effective for stabilizer applications are first identified by using participation factors. Then an efficient algorithm based on decentralized pole assignment is proposed for the determination of the parameters of the power system stabilizers which, due to the difficulty associated with the communication among the geographically dispersed generating stations in a large power system, are essentially decentralized compensators using local generator outputs as their feedback signals. The proposed method is computationally efficient and can be applied to any large-scale system. The simplicity and effectiveness of the proposed method are demonstrated by an example of stabilizer design for a practical power system.

1988-08-01

474

Advanced resin cleaning system  

International Nuclear Information System (INIS)

Novel and unprecedented ion exchange resin cleaning system, for use in BWR plants and featuring a vibration separator and basic design factors of Radiological Solutions, Inc., had been delivered to Tokai No. 2 Power Station, Japan Atomic Power Company, in October 2005. This compactly-designed system effectively separates crud and resin fines from ion exchange resins, with no clogging of separation screens. It generates minimized waste liquid and has a specially designed over-pack cleaning tank. The system has been in operation for about 2 years and half now and favorable operational data, such as crud and sulfate concentration decrease in feed water and reactor water respectively, and evaluation results have been reported from Japan Atomic Power Company and so on. (author)

2008-07-01

475

Advanced Neutron Source: Plant Design Requirements  

Energy Technology Data Exchange (ETDEWEB)

The Advanced Neutron Source will be a new world-class facility for research using hot, thermal, cold, and ultra-cold neutrons. The heart of the facility will be a 330-MW (fission), heavy-water cooled and heavy-water moderated reactor. The reactor will be housed in a central reactor building, with supporting equipment located in an adjoining reactor support building. An array of cold neutron guides will fan out into a large guide hall, housing about 30 neutron research stations. Appropriate office, laboratory, and shop facilities will be included to provide a complete facility for users. The ANS is scheduled to begin operation at the Oak Ridge National Laboratory early in the next decade. This PDR document defines the plant-level requirements for the design, construction, and operation of ANS. It also defines and provides input to the individual System Design Description (SDD) documents. Together, this PDR document and the set of SDD documents will define and ...

1990-07-01

476

Advanced Flue Gas Desulfurization (AFGD) Demonstration Project. Technical progress report No. 13, January 1, 1993--March 31, 1993  

Science.gov (United States)

The goal of this project is to demonstrate that, by combining state-of-the-art technology, highly efficient plant operation and maintenance capabilities and by-product gypsum sales, significant reductions of SO{sub 2} emissions can be achieved at approximately one-half the life cycle cost of a conventional Flue Gas Desulfurization (FGD) system. Further, this emission reduction is achieved without generating solid waste and while minimizing liquid wastewater effluent. Basically, this project entails the design, construction and operation of a nominal 600 MWe AFGD facility to remove SO{sub 2} from coal-fired power plant flue gas at the Northern Indiana Public Service Company`s Bailly Generating Station.

1994-08-01

477

AZSh protective circuit breaker system  

Energy Technology Data Exchange (ETDEWEB)

The AZSh protective circuit breakers developed by the VNIIVEh Institute and the Prokop'evsk plant for mine automation will replace a number of circuit breaker systems used in underground coal mines in the USSR. The standardized AZSh circuit breaker generation consists of 3 basic types: the AZSh-1, the AZSh-2 and the AZSh-3 systems for power systems with 380 or 660 V voltage. Block scheme of the AZSh system is given. Its specifications are discussed. The AZSh circuit breakers are used for protection of transformer stations from overload and heating as well as for automatic shutdown of energy supply to a power system in emergency situations. Design, basic elements and operation of the AZSh-1, the AZSh-2 and the AZSh-3 protective circuit breakers is evaluated. Commercial production of the AZSh started in 1983.

1984-08-01

478

A probabilistic approach to the estimation of lifetime distribution of Alloy 800 SG tubing  

Energy Technology Data Exchange (ETDEWEB)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. In planning refurbishment of CANDU stations, a key concern is the longevity of existing SGs up to the 60 year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and estimates it based on experimental data specific to CANDU operating conditions. The paper presents a more advanced probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of degradation on reliability of SG tubing. (author)

2008-07-01

479

A probabilistic approach to the estimation of lifetime distribution of Alloy 800 SG tubing  

International Nuclear Information System (INIS)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. In planning refurbishment of CANDU stations, a key concern is the longevity of existing SGs up to the 60 year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and estimates it based on experimental data specific to CANDU operating conditions. The paper presents a more advanced probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of degradation on reliability of SG tubing. (author)

2008-06-01

480

Wind power - research and development. The wind turbine industry`s view of the promotion of state-supported research and development; Vindkraft - forskning og udvikling. Vindmoelleindustriens syn paa offentlig forsknings- og udviklingsfremme  

Energy Technology Data Exchange (ETDEWEB)

The windmill industry in Denmark is currently confronted with making a choice between competing technologies so that the role of the stimulus of state subsidies for research has lately increased in importance. The Ministry of Energy, it is claimed, must be aware of this as possibilities for making use of research results are dictated by the market and competition. The industry is not sympathetic to the idea of state research contracts with specified goals for which manufacturers must produce a technical solution. Consultancy firms should work towards solving general problems which could help the industry as a whole. Wind turbines which are cheap to produce and operate are of more interest to industry than those which are technologically advanced or of a lighter construction. It is not thought to be advantageous to concentrate the allocation of subsidies on one key project chosen by the Ministry itself, such as the current intense interest in turbine blades. Aerodynamics, noise ...

1995-10-01

481

Wind power - research and development. The wind turbine industry's view of the promotion of state-supported research and development  

International Nuclear Information System (INIS)

The windmill industry in Denmark is currently confronted with making a choice between competing technologies so that the role of the stimulus of state subsidies for research has lately increased in importance. The Ministry of Energy, it is claimed, must be aware of this as possibilities for making use of research results are dictated by the market and competition. The industry is not sympathetic to the idea of state research contracts with specified goals for which manufacturers must produce a technical solution. Consultancy firms should work towards solving general problems which could help the industry as a whole. Wind turbines which are cheap to produce and operate are of more interest to industry than those which are technologically advanced or of a lighter construction. It is not thought to be advantageous to concentrate the allocation of subsidies on one key project chosen by the Ministry itself, such as the current intense interest in turbine blades. Aerodynamics, noise ...

482

The Burrard utilization study report: Review and analysis of the future role of Burrard Thermal Generating Station  

Energy Technology Data Exchange (ETDEWEB)

The Burrard Thermal Generating Station is located at Port Moody, British Columbia, and burns natural gas to supply steam to six turbine units for generating up to 912 MW of electricity. The Burrard plant accounts for ca 8.7% of the provincial generating capability. Burrard is expected to continue to fill a vital role as a supplier of displaceable firm energy to the British Columbia Hydro system. In parallel with a renewed focus on Burrard from a system planning perspective, there have also been concerns about air pollution from the plant in the context of its possible effect on the region's air quality. To address this and other issues surrounding Burrard's future, B.C. Hydro established a project team to conduct a utilization study. The team's work focused on the role of Burrard in providing a reliable and profitable role in electricity generation, the options for dealing with the air quality issue, and the implications of choosing one ...

1993-01-01

483

System control and data acquisition of the two new FWCD RF systems at DIII-D  

Energy Technology Data Exchange (ETDEWEB)

The Fast Wave Current Drive (FWCD) system at DIII-D has increased its available radio frequency (RF) power capabilities with the addition of two new high power transmitters along with their associated transmission line systems. A Sun Sparc-10 workstation, functioning as the FWCD operator console, is being used to control transmitter operating parameters and transmission line tuning parameters, along with acquiring data and making data available for integration into the DIII-D data acquisition system. Labview, a graphical user interface application, is used to manage and control the above processes. This paper will discuss the three primary branches of the FWCD computer control system: transmitter control, transmission line tuning control, and FWCD data acquisition. The main control program developed uses VXI, GPIB, CAMAC, Serial, and Ethernet protocols to blend the three branches together into one cohesive system. The control of the transmitters utilizes VXI technology to communicate ...

1995-10-01

484

Study of the distribution of gamma emitters radionuclides between a pollution abatement factory and its surrounding environment; Case of the water treatment plant of the Grand Caen district. Study report; Etude de la repartition de radionucleides artificiels emetteurs gamma entre une usine de depollution et son milieu environnant; Cas de la station d'epuration du District du Grand Caen. Rapport d'etude  

Energy Technology Data Exchange (ETDEWEB)

Except nuclear industry, diverse structures (hospitals, of research or manufacturers) can have appeal to the use of radioisotopes conditioned under unsealed shape. Such practices lead to tolerate releases in environment in the respect of a statutory device. So the collective network can contain radioisotopes the future of which is going to depend partially on the cleaning applied to waste water. This study through the analysis of a concrete case, has for objective to inform about the future of gamma radioelements present in waste water treated by a wastewater treatment plant. The contamination of the network is essentially due to Tc{sup 99} and I{sup 131}, radioelements present whatever the working day and the hour considered. The total estimated in-load for a day is important, of the order of 4000 MBq for Tc{sup 99} and 15 to 300 MBq for I{sup 131}. The assessment of cleaning of the station shows that this one plays a role towards this pollution through these ...

2007-07-01

485

Study of radionuclide contributing to dose rates in 540 MWe plant environment  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station Unit-4 is first 540 MWe pressurized heavy water reactor in India. It achieved criticality on 06th March 2005 and then operated at full power i.e 500 MWe. Radiation workers during the normal operation and reactor shutdown are exposed to radiation field. The control of dose rates and the collective dose of the radiation workers is most important for the best performance of the reactor. Experience gained during the operation of the 220 MWe reactors has shown that the Moderator system, primary heat transport system, annulus gas system and moderator cover gas system are the main systems contributing to the dose rate and collective dose. In order to identify the radio nuclides contributing to the radiation field, study was undertaken at TAPS Unit-4. Various samples from the Moderator, primary heat transport system, annulus gas system and moderator cover gas system were collected and analysed for the spectrometric analysis. This paper ...

2005-11-23

486

Studies of aerosol formation in power plant plumes - II. Secondary aerosol formation in the Navajo generating station plume  

Energy Technology Data Exchange (ETDEWEB)

Aerosol and gas measurements were made with the University of Minnesota Mobile Laboratory (UMML) during the VISTTA programme near Page, Arizona. The UMML was stationed on Zilnez Mesa approx. 65 km east of the Navajo coal-fired power plant. Measurements were made both in and out of the power plant plume and were made during the day and night. Measured parameters included aerosol size distributions, Aitken nuclei count, ozone and sulphur dioxide concentrations, the aerosol light scattering coefficient, and meteorological parameters including ultraviolet radiation intensity. Concentrations of NO and NO/SUB/x were occasionally measured. Data show clear evidence of gas-to-particle conversion in the plume with aerosol volume being added in the 0.01 MUm - 0.32 MUm dia. range and new particles being formed. The observed excess aerosol volume depends strongly upon the SO/SUB/2 concentrations and the time of day with none observed in plume parcels which were not exposed to ...

1981-01-01

487

Simulations of the design basis accident at conditions of power increase and the o transient of MSIV at overpressure conditions of the Laguna Verde Power Station; Simulaciones del accidente base de diseno a condiciones de aumento de potencia y del transitorio de cierre de MSIV a condiciones de sobrepresion de la Central Laguna Verde  

Energy Technology Data Exchange (ETDEWEB)

This document presents the analysis of the simulation of the loss of coolant accident at uprate power conditions, that is 2027 MWt (105% of the current rated power of 1931MWt). This power was reached allowing an increase in the turbine steam flow rate without changing the steam dome pressure value at its rated conditions (1020 psiaJ. There are also presented the results of the simulation of the main steam isolation va/ve transient at overpressure conditions 1065 psia and 1067 MWt), for Laguna Verde Nuclear Power Station. Both simulations were performed with the best estimate computer code TRA C BF1. The results obtained in the loss of coolant accident show that the emergency core coolant systems can recover the water level in the core before fuel temperature increases excessively, and that the peak pressure reached in the drywell is always below its design pressure. Therefore it is concluded that the integrity of the containment is not challenged during a loss of ...

2001-07-01

488

Radiofrequency electromagnetic fields in the Cookridge area of Leeds  

Energy Technology Data Exchange (ETDEWEB)

On the 8 and 9 May 2002 representatives of the National Radiological Protection Board (NRPB) performed a radiofrequency electromagnetic field survey in the Cookridge area of Leeds in order to assess exposure to radio signals from transmitters mounted on a water tower/a lattice tower and a radio station tower. Guidelines on limiting exposure to radio signals have been published by NRPB and the International Commission on Non-Ionizing Radiation Protection (ICNIRP). These guidelines are designed to prevent established adverse effects on human health. During this survey, the total exposures due to all radio signals from 30 MHz to 18000 MHz (18 GHz) were measured. This frequency range was chosen as it includes mobile phone base station transmissions, which are at around 900 and 1800 MHz and super high frequency (SHF) transmissions from most of the large microwave dish antennas mounted on the towers. In addition, other major sources of radiofrequency ...

2002-07-01

489

PDIM - multifunction regulator; PDIM - Die integrierte Druckreduzier- und Messanlage fuer Gas  

Energy Technology Data Exchange (ETDEWEB)

The PDIM multifunction regulator offers in one single unit the basic functions filtering, slamshut safety valve, pressure reduction and a gas flow straightening vane. This concept formulated by the engineer J.-P. Cornil is a Gaz de France patent. Developed and manufactured by a French industrial company it incorporates some astute innovations in the field of fluid dynamics. Its technical caracteristics make a significant step forward in gas technology. Since the first unit was brought into service over 1000 PDIM units have been built and incorporated in gas regulating and metering stations for transport, distribution and industrial applications. The very compact nature of the PDIM enhanced by its direct bolting to a turbine or other type of gas meter leads to small size stations allowing lower cost projects and making it easier to set in populated or architecturally significant areas. (orig.) [Deutsch] Der PDIM ist eine Verschmelzung der ...

1997-12-31

490

Monte Carlo simulations of precise timekeeping in the Milstar communication satellite system  

Science.gov (United States)

The Milstar communications satellite system will provide secure antijam communication capabilities for DOD operations into the next century. In order to accomplish this task, the Milstar system will employ precise timekeeping on its satellites and at its ground control stations. The constellation will consist of four satellites in geosynchronous orbit, each carrying a set of four rubidium (Rb) atomic clocks. Several times a day, during normal operation, the Mission Control Element (MCE) will collect timing information from the constellation, and after several days use this information to update the time and frequency of the satellite clocks. The MCE will maintain precise time with a cesium (Cs) atomic clock, synchronized to UTC(USNO) via a GPS receiver. We have developed a Monte Carlo simulation of Milstar's space segment timekeeping. The simulation includes the effects of: uplink/downlink time transfer noise; satellite crosslink time transfer noise; satellite ...

1995-05-01

491

Large lignite steam generators with circulating fluidized bed combustion. Operating experience with a 290 t/h and 400 t/h plant in the RWE power station at Goldenberg; Grosse Braunkohle-Dampferzeuger mit zirkulierender Wirbelschichtfeuerung. Betriebserfahrungen aus der 290 t/h- und der 400 t/h-Anlage im Kraftwerk Goldenberg der RWE Energie AG  

Energy Technology Data Exchange (ETDEWEB)

Early in 1988 RWE decided to overhaul the power station at Goldenberg. This was necessary due to the age of the plant, the obligation to supply heat and process steam and recent amendments of environmental legislation. After analysing demands and needs one developed a plant concept with a 290 t/h and a 400 t/h steam generator. Due to lack of space the decision was made in favour of a circulating atmospheric fluidised bed combustion instead of steam generators with pulverised lignite combustion as these steam generators take up much more space due to the legally required desulphurisation plants for gaseous emissions. Apart from generating steam RWE wishes to gain experience with this combustion technology and test it for suitability and use in large-scale plant. (orig./KO) [Deutsch] Aufgrund des fortgeschrittenen Alters, der aktuellen Umweltschutzgesetzgebung sowie bestehender Versorgungsverpflichtungen fuer Waerme und Prozessdampf wurde Anfang 1988 von der RWE ...

1995-12-31

492

Hydrogeologic investigations related to seepage and instability phenomena within and adjacent the earth structures at Grand Rapids Generating Station, Manitoba  

Energy Technology Data Exchange (ETDEWEB)

This study evaluated potential hydrogeologic mechanisms that may account for increasing moisture content conditions within the sediments of hydroelectric earth dams. Many such dams in Canada are reaching their life spans of approximately 40 years, therefore this study is considered to be an important and timely undertaking. The objective was to develop a method to numerically assess transient groundwater flow processes within old earth structures. The focus of this study was central Manitoba's Grand Rapids Generating Station where progressive movement within the till overburden has been observed since 1977. The possible source of water which is causing higher moisture content and weakness in the overburden material may be the slow wetting-up of the core and progressive increase in seepage to the downstream side. The evolution of flow through the core was evaluated with a modelling program called FRAC3D-VS which accounts for transient groundwater flow under ...

2002-07-01

493

Heat transfer characteristics of horizontal steam generators under natural circulation conditions  

Energy Technology Data Exchange (ETDEWEB)

This paper deals with the heat transfer characteristics of horizontal steam generators, particularly under natural circulation (decay heat removal) conditions on the primary side. Special emphasis is on the inherent features of horizontal steam generator behaviour. A mathematical model of the horizontal steam generator primary side is developed and qualitative results are obtained analytically. A computer code, called HSG, is developed to solve the model numerically, and its predictions are compared with experimental data. The code is employed to obtain for VVER 440 steam generators quantitative results concerning the dependence of primary-to-secondary heat transfer efficiency on the primary side flow rate, temperature and secondary level. It turns out that the depletion of the secondary inventory leads to an inherent limitation of the decay energy removal in VVER steam generators. The limitation arises as a consequence of the steam generator tube bundle geometry. As an example, it is ...

1996-10-01

494

Grid-Search Location Methods for Ground-Truth Collection from Local and Regional Seismic Networks  

Energy Technology Data Exchange (ETDEWEB)

The objective of this project is to develop improved seismic event location techniques that can be used to generate more and better quality reference events using data from local and regional seismic networks. Their approach is to extend existing methods of multiple-event location with more general models of the errors affecting seismic arrival time data, including picking errors and errors in model-based travel-times (path corrections). Toward this end, they are integrating a grid-search based algorithm for multiple-event location (GMEL) with a new parameterization of travel-time corrections and new kriging method for estimating the correction parameters from observed travel-time residuals. Like several other multiple-event location algorithms, GMEL currently assumes event-independent path corrections and is thus restricted to small event clusters. The new parameterization assumes that travel-time corrections are a function of both the event and station location, ...

2003-07-24

495

From Daya Bay to Ling Ao. The benefits of a duplication policy  

International Nuclear Information System (INIS)

Over the past 15 years, the People's Republic of China has experienced very rapid economic growth of annual average 8%, which must be supported by fast expanding energy production, notably of electricity. China has the considerable amount of coal resources, but most of these resources are located in the north of the country, and the vast hydroelectric potential in Southwestern China is difficult to develop. Therefore, in the coastal provinces of Southeast China, where economic expansion is greatest, nuclear power has been chosen to meet the need. The Qinshan No. 1 PWR with 300 MWe output is the first Chinese nuclear power facility, and started the operation in 1992. Two 985 MWe PWRs have been operated since 1994 at Daya Bay. The construction of Qinshan No. 2 and 3 PWRs of 600 MWe each are in progress, and are expected to start the operation in 2001. These plants were designed by China based on the Framatome technology. Two more 985 MWe plants will be constructed on Ling Ao site, and ...

1996-10-01

496

Externally-fired combined cycle: An effective coal fueled technology for repowering and new generation  

Energy Technology Data Exchange (ETDEWEB)

The Externally-Fired Combined Cycle (EFCC) is an attractive emerging technology for powering high efficiency combined gas and steam turbine cycles with coal or other ash bearing fuels. In the EFCC, the heat input to a gas turbine is supplied indirectly through a ceramic air heater. The air heater, along with an atmospheric coal combustor and ancillary equipment, replaces the conventional gas turbine combustor. A steam generator located downstream from the ceramic air heater and steam turbine cycle, along with an exhaust cleanup system, completes the combined cycle. A key element of the EFCC Development Program, the 25 MMBtu/h heat-input Kennebunk Test Facility (KTF), has recently begun operation. The KTF has been operating with natural gas and will begin operating with coal in early 1995. The US Department of Energy selected an EFCC repowering of the Pennsylvania Electric Company`s Warren Station for funding under the Clean Coal Technology Program Round V. The ...

1995-06-01

497

Effect of earthquakes on ambient noise cross-correlation function  

Science.gov (United States)

Surface wave tomography method based on analysis of ambient noise is widely used during the last decade. It is assumed that correlated component of noise is composed of surface waves generated by sources distributed over the Earth's surface more or less uniformly. In such a case the cross-correlation function (CCF) at two stations may be considered as the Green's function of surface wave. This function should be symmetric relatively to zero time. However analysis of CCF at the stations located at the East-European Platform shows that as a rule CCF is characterized with a strong asymmetry. Since "purered noise cannot be extracted from seismic records due to superposition of earthquake signals, the method for calculation of CCF includes amplitude normalization for suppression of earthquakes that reduces signals from earthquakes to a noise level. The parts of records containing waves from earthquakes are neglected because of their short duration. ...

2011-09-01

498

Climate Impacts on US Energy Infrastructure: A New High Resolution Model, Policy Implications and Feedbacks  

Science.gov (United States)

We describe the development of a fully coupled climate model configuration where the Community Climate System Model (CCSM) has been coupled with the VERDE (Visualizing Energy Resources Dynamically on the Earth) analysis modules that compute the response of the electric grid to temperature drivers. The VERDE model includes datasets characterizing the 26,500 sub-stations and 6,000 power generation stations fuel mix, efficiency, service areas, and future performance and these have been geo-located on a 1.4 degree latitude by 1.4 degree longitude CCSM grid (T85). The total electric customers have been computed using conversions derived from economic structure and population data. The carbon emissions per customer and the power generation in megawatts electric (MWe) have also been placed on reconciled 1 km, 4 km and the T85 climate model grid. The CCSM temperature for the present and future have been extracted from the climate model output and ...

2010-12-01

499

Archive monitoring of pollutants in the Dee River using SIMS analysis of mussels  

International Nuclear Information System (INIS)

Full text: Mt Morgan was mined for copper and gold from 1882 to 1982 and subsequent tailings re-processing ceased in 1990. Direct and accidental deposition of tailings into the adjacent Dee River and acid mine drainage from the mine site continues to impact the Dee River. The Queensland Department of Natural Resources gauging and monitoring station at Kenbula (adjacent to the mine) continuously monitors pH of around 2.8. Twenty kilometres downstream of the mine the pH improves to 3.5. Elevated sediment metal concentrations have been recorded over 50 kilometres downstream in investigations conducted by CSIRO (Jones et al. 1995, 1996) and others. Biological monitoring by Mackey (1988) and subsequently by Duivendoorden (1995,1997), confirmed significant impact on the fish, macrophyte of macro invertebrate populations downstream of the mine. The current AINSE sponsored project will investigate the use of mussels (genus Allathryia) to archive the pollutant load in the ...

2000-11-29

500

A High-Frequency Secondary Event During the 2004 M6.0 Parkfield Earthquake  

Science.gov (United States)

We present an image of the rupture propagation of the 2004 M6.0 Parkfield earthquake using records from a dense network of local strong motion stations. We back-propagate high-frequency waveforms in 3D with a method, similar to reverse time migration, to obtain an estimate of the distribution of radiated high-frequency seismic energy in space and time. The image is forced to be coherent at the known hypocenter location and the quake origin time by applying small static time shifts obtained using waveform cross-correlation. We observe that the Parkfield earthquake radiated a distinct secondary high-frequency phase, which is located about 12.5~km northwest of the hypocenter with an onset of seismic radiation about 5~s after the rupture initiation. The time history of the back-projection suggests a rupture velocity of 2.5~km/s between hypocenter and subevent. The back-projection result is confirmed by inversion of picked arrival times of the secondary event clearly ...

2007-12-01