WorldWideScience
1

Radiofrequency ablation of the gastrointestinal tract with a stent-like electrode: experimental study  

Energy Technology Data Exchange (ETDEWEB)

To assess the technical feasibility of a newly designed stent-like electrode in rabbits. A stent-like electrode was knitted from a single thread of nitinol wire and interconnected to a generator using similar wire. In order to gauge the extent of radiofrequency ablation (RFA), we measured the depth of the ablated area in cow liver using a combination of 180-sec time intervals and 20- watt power increments. For data processing, Cox regression analysis was used. RFA was also applied to the small intestine of rabbits using this stent-like electrode under six different sets of conditions: 10 watts for 1 min, 10 watts for 2 mins, 20 watts for 1 min, 20 watts for 2 mins, 30 watts for 1 min, and 30 watts for 2 mins. To determine the gross and microscopic findings, six animals were sacrificed immediately after the procedure and the results obtained under the different sets of conditions were correlated. Eight ...

2003-03-01

2

Antimicrobial Susceptibility of Haemophilus ducreyi  

UK PubMed Central (United Kingdom)

The susceptibility of 19 isolates of Haemophilus ducreyi from a recent chancroid outbreak and four reference strains was determined in vitro to 13 antimicrobial agents. The rabbit intradermal...Full Text Available

1978-04-01

3

["3H]QNB binding and contraction of rabbit colonic smooth muscle cells  

International Nuclear Information System (INIS)

The authors used radioligand binding and studies of cell contraction to characterize muscarinic receptors on dispersed smooth muscle cells from rabbit proximal and distal colon. Cells obtained after serial incubations in collagenase were used to measure binding of tritiated quinuclidinyl benzilate (["3H]QNB). At 37 degree C, specific ["3H]QNB binding was saturable and linearly related to cell number. Nonlinear regression analysis was used to determine the affinity of ["3H]QNB for its receptor. The IC_5_0 for the muscarinic agonists bethanechol and oxotremorine were 80 and 0.57 #mu#M, respectively. Hill coefficients were 0.67 for both, suggesting more complex interaction involving receptors of different affinities. In studies of cell contraction, bethanechol stimulated a dose-dependent decrease in cell length with half the maximal contraction occurring at 100 pM. These results suggest that (1) contraction is mediated by ...

1987-01-01

4

Removal rate of ( sup 3 H)hyaluronan injected subcutaneously in rabbits  

Energy Technology Data Exchange (ETDEWEB)

Hyaluronan is an important constituent of the extracellular matrix in skin, and recent studies suggest that there is a pool of easily removable (free) hyaluronan drained by lymph. The removal rate of free hyaluronan in skin was measured from the elimination of ({sup 3}H)hyaluronan, injected subcutaneously in 13 rabbits. The removal of radioactivity was determined from appearance of {sup 3}H in plasma. During the first 24 h after injection, 10-87% of the tracer entered blood, less in injectates with high concentrations of hyaluronan. The removal was monoexponential with a half-life of 0.5-1 day when concentration of hyaluronan was 5 mg/ml or less. When hyaluronan concentration was 10 mg/ml or higher, the removal was slow for about 24 h and then became similar to that in experiments with low hyaluronan concentration. Free hyaluronan at physiological concentrations is thus turned over with the same rate as serum albumin, ...

1990-08-01

5

Heterophyle antibodies causing false positive radio-immunoassay results a case report  

International Nuclear Information System (INIS)

A case report of falsely elevated serum hormone values measured by radio-immunoassay (RIA) is described. The radio-immunoassays concerned have a first antibody raised in rabbits and mostly a separation technique based on a second antibody-solid phase system. The presence of heterophyle (anti-rabbit) antibodies in patients' serum is proved.

6

How Much Does the Midline Incision Add to Urethral Diameter After Tubularized Incised Plate Urethroplasty? An Experimental Animal Study  

British Library Electronic Table of Contents (United Kingdom)

PurposeWe objectively quantified the gain in urethral diameter and the effect of stenting after tubularized incised plate urethroplasty in a rabbit hypospadias model. Materials and MethodsWe created a hypospadias model in 12 New Zealand white male rabbits by excising the ventral urethra. A 3 cm tattoo line was made longitudinally in the dorsal urethral plate midline. Two weeks later a 2 cm relaxing incision was made in the middle part of the tattooed line. The stretched incision width between the tattooed edges was measured, followed by urethral plate tubularization. Six rabbits were stented and 6 were nonstented. Two weeks later the animals were sacrificed and the distance separating the tattoo was measured at the midpoint of the tattooed line. Transverse sections at this point were exami...

2011-01-01

7

Mechanism of sup(99m)Tc-methylene diphosphonate (sup(99m)Tc-MDP) localization in experimental studies of bone tumors. Microautoradiography method  

Energy Technology Data Exchange (ETDEWEB)

(Materials and Methods) (I) VX/sub 2/ carcinoma was transplanted to the rabbit tibia, sup(99m)Tc-MDP was intravenously injected when bone destruction was radiologically seen. Preoperative scintigraphs, postoperative one of the resected tibia and fibra and scintigraphs of sliced tumor were compared with each other. Tissue fragments were collected from the sliced tumor, and RI was measured to compare concentration rates at different parts together with histological investigations. (II) Tetracycline was given to the rabbit of Experiment (I) to compare with the concentration of sup(99m)Tc-MDP. (III) Microautoradiography method was done on the experimental animals for investigation of the concentration of sup(99m)Tc-MDP. (Results) (I) Localization of sup(99m)Tc-MDP was increased at the sites of tumorous bone formation, of reactive bone formation at tumor edges, and of cartilage calcification, with little concentration at tumor ...

1981-12-01

8

Absorption of lead from the bronchial region of the lung  

International Nuclear Information System (INIS)

Experiments have been reported previously in which lead-212 ions with lead carrier were instilled into the lungs of anaesthetised rabbits. Experiments were also reported in which bismuth-207 chloride was instilled into rabbit lung. To check that the chloride compound was cleared in the same way as ions instilled in isolation, lead-203 chloride has been instilled in three rabbits. Measurements of absorption of ionic lead have been repeated using the radon-222 daughter, lead-214. Rates of clearance from the lung of "2"0"3Pb as the chloride and "2"1"2Pb ions are compared, and retention functions are derived. Clearance from the lung of "2"1"4Pb ions is also shown, and retention functions are derived. (U.K.).

1978-03-01

9

Mechanism of sup(99m)Tc-methylene diphosphonate (Tc-MDP) localization in clinical and experimental studies of bone tumors  

Energy Technology Data Exchange (ETDEWEB)

Tc-MDP 10mCi was intravenously given preoperatively to 20 patients with primary bone tumors and 1 with a metastatic bone tumor. Preoperative and postoperative scintigraphs of resected tumor and scintigraphs of sliced tumor were compared. Tissue fragments were collected from the sliced tumor, and RI measured to compare concentration rates at different areas. Histological investigations were also done. Localization of Tc-MDP was increased at sites of tumorous bone formation, of reactive bone formation at tumor edges, and of cartilage calcification, with little concentration at tumor cells or necrotic tissue. VX/sub 2/ carcinoma was transplanted into the rabbit tibia, Tc-MDP was intravenously injected when bone destruction was radiologically evident, and investigations were done as in the clinical cases. In experimental bone tumor, increased uptake localization of Tc-MDP was much the same as in clinical cases. Tetracycline was given to the ...

1981-06-01

10

Rapidly adapting receptors in a rabbit model of mitral regurgitation  

UK PubMed Central (United Kingdom)

Unlike in normal rabbits, pulmonary rapidly adapting receptors (RARs) in rabbits with chronic mitral regurgitation (MR) do not respond to small changes in extravascular...Full Text Available

1999-12-15

11

Phosphorylation of sites 3 and 2 in rabbit skeletal muscle glycogen synthase by a multifunctional protein kinase (ATP-citrate lyase kinase)  

Energy Technology Data Exchange (ETDEWEB)

A multifunctional protein kinase, purified from rat liver as ATP-citrate lyase kinase, has been identified as a glycogen synthase kinase. This kinase catalyzed incorporation of up to 1.5 mol of and)2numberSPO4/mol of synthase subunit associated with a decrease in the glycogen synthase activity ratio from 0.85 to a value of 0.15. Approximately 65-70% of the TUPO4 was incorporated into site 3 and 30-35% into site 2 as determined by reverse phase high performance liquid chromatography. This multifunctional kinase was distinguished from glycogen synthase kinase-3 on the basis of nucleotide and protein substrate specificities. Since the phosphate contents in glycogen synthase of sites 3 and 2 are altered in diabetes and by insulin administration, the possible involvement of the multifunctional kinase was explored. Glycogen synthase purified from diabetic rabbits was phosphorylated in vitro by this multifunctional kinase at only 10% of the rate ...

1985-10-05

12

Flow-induced changes in pial artery compliance registered with a non-invasive method in rabbits  

British Library Electronic Table of Contents (United Kingdom)

Aim: This study was performed: 1) to assess the relationship between blood flow velocity in the internal carotid artery (CBFICA) and pial artery pulsation (cc-TQ) and 2) to evaluate flow-induced changes in pial artery compliance. Methods: Experiments were performed on 10 crossbred male rabbits. Heart rate (HR), blood pressure (BP), left ventricle ejection fraction (LVEF), CBFICA, the systolic-diastolic blood volume fraction in the brain circulation (CBFSDF) and cc-TQ were recorded after glucagon and acetazolamide administration. cc-TQ was measured with near-infrared transillumination back scattering sounding (NIR-T/BSS), LVEF and CBFSDF with gated scintigraphy and BP and CBFICA with electromagnetic pressure and flow transducers, respectively. Doses of drugs were chosen to exert a haemodyna...

2011-01-01

13

Heated lipiodol as an embolization agent for transhepatic arterial embolization in VX2 rabbit liver cancer model  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate the therapeutic effect of heated (60 deg. C) lipiodol via hepatic artery administration in a rabbit model of VX2 liver cancer. Materials and methods: Thirty male New Zealand white rabbits were randomly divided into three groups with 10 rabbits assigned to each group. VX2 carcinoma cells were surgically implanted into the left hepatic lobe. The tumors were allowed to grow for 2 weeks, and studies were performed until the diameter of the tumors detected by ultrasonograph reached 2-3 cm. Under anesthesia, trans-catheter hepatic arterial embolization was performed and doxorubicin-lipiodol (37 deg. C) (1 mL), lipiodol (60 deg. C) (1 mL) or control (physiological saline (37 deg. C) (1 mL)) solution was injected into the hepatic arteries of animals in the three groups. One week later, the volume of the tumor was measured by ultrasonograph again. The serum of all ...

2010-02-15

14

Growth hormone-like factor produced by the tapeworm, Spirometra mansonoides, displaces human growth hormone (hGH) from its receptors on cultured human lymphocytes  

International Nuclear Information System (INIS)

An analogue of hGH isolated from plerocercoids of the tapeworm Spirometra mansonoides displaces ["1"2"5I]hGH from its receptors in rabbit, rat, and hamster liver membranes. Biologically, plerocercoid growth factor (PGF) is more similar to hGH than to other mammalian GH's but has not been shown to bond human cells. Receptors specific for hGH have been described on cultured human lymphocytes (IM-9). In this study, the authors compared the binding of PGF and hGH in IM-9 cells and in rabbit hepatic membranes. IM-9 lymphocytes (12 x 10"6 cells/tube) were incubated with ["1"2"5I]hGH and increasing concentrations of hGH (ng/ml) or PGF (serial dilutions) for 90 min at 30"0 C. Specific binding (B_0 - NSB) was determined for each dose of hGH or PGF and the binding curves were analyzed by logit-log regression. The results show that PGF displaced ["1"2"5I]hGH from human cells in a dose dependent manner (r = 0.98). Based on the IM-9 ...

1986-04-13

15

Immunological correlates for protection against intranasal challenge of Bacillus anthracis spores conferred by a protective antigen-based vaccine in rabbits.  

Science.gov (United States)

Correlates between immunological parameters and protection against Bacillus anthracis infection in animals vaccinated with protective antigen (PA)-based vaccines could provide surrogate markers to evaluate the putative protective efficiency of immunization in humans. In previous studies we demonstrated that neutralizing antibody levels serve as correlates for protection in guinea pigs (S. Reuveny et al., Infect. Immun. 69:2888-2893, 2001; H. Marcus et al., Infect. Immun. 72:3471-3477, 2004). In this study we evaluated similar correlates for protection by active and passive immunization of New Zealand White rabbits. Full immunization and partial immunization were achieved by single and multiple injections of standard and diluted doses of a PA-based vaccine. Passive immunization was carried out by injection of immune sera from rabbits vaccinated with PA-based vaccine prior to challenge with B. anthracis spores. Immunized ...

2006-01-01

16

Horizontal Transmissible Protection against Myxomatosis and Rabbit Hemorrhagic Disease by Using a Recombinant Myxoma Virus  

UK PubMed Central (United Kingdom)

We have developed a new strategy for immunization of wild rabbit populations against myxomatosis and rabbit hemorrhagic disease (RHD) that uses recombinant viruses based on a naturally attenuated field...Full Text Available

2000-02-01

17

Mineral analysis in experimental corneal scars. An EDAX study  

Energy Technology Data Exchange (ETDEWEB)

Central penetrating excisional wounds were made in the corneas of 12 rabbits and 10 trout. The scar tissue and the surrounding cornea were compared using a new method for assessing inorganic elements in the cornea: the scanning electron microscopy and energy dispersive analysis of x-ray (EDAX). Semiquantitative determination of inorganic elements within the range of atomic numbers 9-93 in the periodic system was performed, comparing the relative concentration of those elements in the scar tissue to the surrounding cornea. Results showed that calcium was the only element higher in the healing wound than in the surrounding cornea.

1988-01-01

18

Prediction and measurement of the neutron environment in OSURR experimental facilities following conversion to LEU  

International Nuclear Information System (INIS)

Neutron energy spectra were measured for two OSURR experimental facilities. The method of multiple foil activation was used with the SAND-II neutron spectrum unfolding code to obtain spectral data for the Central Irradiation Facility and Rabbit tube. Limited data was obtained for the thermal column using only gold foils. Calculations were made of the neutron environment in various locations using the MORSE code. A shift towards higher neutron energies was observed comparing results for LEU and HEU cores. A slight loss in total thermal neutron flux was measured for all positions. Calculational results show reasonable agreement with measured data.

1993-07-01

24

Plugging the biopsy tract in rabbit liver : gelfoam, fibrin sealant and NBCA  

International Nuclear Information System (INIS)

To evaluate the effect of plugging the biopsy tract in rabbit liver and the pathologic changes caused by plugging materials. Thirty-two New Zealand White rabbits were divided into four groups (eight rabbits in each) and compared with one another. They were labeled group A (control), B (gelfoam), C (fibrin sealant) or D (NBCA). the liver was exposed and biopsied with an 18G disposable biopsy gun. The inner Tru-cut needle was withdrawn and plugging was undertaken through the outer cannula of the biopsy gun. Bleeding times of each material were compared. The rabbits were sacrificed and pathologically evaluated for 17 days.

1998-07-01

25

Species comparison of acute inhalation toxicity of ozone and phosgene  

Energy Technology Data Exchange (ETDEWEB)

A comparison of the concentration-response effects of inhaled ozone (O/sub 3/) and phosgene (COCl/sub 2/) in different species of laboratory animals was made in order to better understand the influence of the choice of species in inhalation toxicity studies. The effect of 4-h exposures to ozone at concentrations of 0.2, 0.5, 1.0, and 2.0 ppm, and to COCl/sub 2/ and 0.1, 0.2, 0.5, and 1.0 ppm was determined in rabbits, guinea pigs, rats, hamsters, and mice. Lavage fluid protein (LFP) accumulation 18-20 h after exposure was used as the indicator of O3- and COCl/sub 2/-induced pulmonary edema. All species had similar basal levels of LFP (250-350 mg/ml) when a volume of saline that approximated the total lung capacity was used to lavage the collapsed lungs. Ozone effects were most marked in guinea pigs, which showed significant effects at 0.2 ppm and above. Mice, hamsters, and rats showed effects at 1.0 ppm O3 and above, while ...

1986-01-01

26

Preparation and dosimetry of radiotherapeutic particles for arthropaties; Preparacion y dosimetria de particulas radioterapeuticas para artropatias  

Energy Technology Data Exchange (ETDEWEB)

It was developed a new formulation of macro aggregates of Samarium 153 ({sup 153} Sm-MH) for the arthropaties treatment. The radio pharmaceutic was prepared by reaction of Samarium 153 chloride (SmCl{sub 3}) in aqueous environment with sodium boron hydride in NaOH 0.5 N. The microscopic analysis shown that the particles have an average size of 4% m (range 1-14 {mu} m). The velocity of sedimentation was 0.008 cm/min with high stability in vitro in human serum. The biological studies in healthy rabbits, shown that the complex is retained inside the articulation still eight days after of the administration of the radiopharmaceutical. Likewise, it is presented the data of absorbed dose in the different target organs, which was determined by thermoluminescent dosimetry (TLD) through the use of a REMCAL phantom (radiation equivalent manikin calibration). (Author)

1999-07-01

27

Regression of atherosclerotic lesions by high density lipoprotein plasma fraction in the cholesterol-fed rabbit.  

UK PubMed Central (United Kingdom)

The effects of homologous plasma HDL and VHDL fractions on established atherosclerotic lesions were studied in cholesterol-fed rabbits. Atherosclerosis was induced by feeding the animals a 0.5% cholesterol-rich...Full Text Available

1990-04-01

28

Magnetic resonance imaging and computational fluid dynamics (CFD) simulations of rabbit nasal airflows for the development of hybrid CFD/PBPK models  

UK PubMed Central (United Kingdom)

The percentages of total airflows over the nasal respiratory and olfactory epithelium of female rabbits were calculated from computational fluid dynamics (CFD) simulations of steady-state inhalation....Full Text Available

2009-05-01

29

Impact of genetic changes to the CRPV genome and their application to the study of pathogenesis in vivo  

UK PubMed Central (United Kingdom)

The cottontail rabbit papillomavirus (CRPV)/rabbit model has been used to study oncogenicity and immunogenicity of different antigens from the papillomavirus genome and has therefore served...Full Text Available

2007-02-20

30

Cryoglobinaemia in rabbits hyperimmunized with a polyvalent pneumococcal vaccine  

UK PubMed Central (United Kingdom)

During the anamnestic response, the sera of four rabbits immunized with a polyvalent pneumococcal vaccine contained large amounts of cryoglobulins belonging to the G and M immunoglobulin classes. These...Full Text Available

1965-10-01

31

Comparison of azlocillin, ceftizoxime, cefoxitin, and amikacin alone and in combination against Pseudomonas aeruginosa in a neutropenic-site rabbit model.  

UK PubMed Central (United Kingdom)

The efficacy of beta-lactam antibiotics and amikacin alone and in various combinations against Pseudomonas aeruginosa was studied in a rabbit model simulating a closed-space infection in a locally neutropenic...Full Text Available

1984-05-01

32

Comparative pharmacokinetics of two prodrugs of zidovudine in rabbits: enhanced levels of zidovudine in brain tissue.  

UK PubMed Central (United Kingdom)

The pharmacokinetics of two prodrugs of zidovudine (AZT), 1,4-dihydro-1-methyl-3-[(pyridylcarbonyl)oxy] ester and isoleucinyl ester (DPAZT and IAZT, respectively), were investigated in a rabbit model...Full Text Available

1993-04-01

34

Fluidic-controlled automatic rabbit system  

International Nuclear Information System (INIS)

... v. 15(10) p. 445-449. automation control equipment fluid flow fluidic control

35

Biological parameters of transgenic rabbits  

British Library Electronic Table of Contents (United Kingdom)

The investigations were conducted at the Center of Biotechnology and Molecular Diagnostics of the All-Russian Animal Husbandry Research Institute, where a number of valuable transgenic animals (rabbits, sheep, and pigs) have been produced over the course of 20 years. The article presents the blood indices of control and transgenic rabbits with an integrated insulin gene.

2011-01-01

36

Data of spleen-scintiscanning after splenectomy  

International Nuclear Information System (INIS)

In 65 adult rabbits of both sexes (2.5 to 6 kg) the following salvaging procedures were performed after simulated trauma: (1) Continuous suture line; (2) closure with fibrin sealant after temporary clamping; (3) hemisplenectomy with omental wrap; (4) suture fixation of fragments and slices of spleen tissue to the peritoneum; (5) suture fixation of spleen fragments to the omentum; (6) extraperitoneal subcutaneous transposition of spleen cubes. In addition, the likelihood of spontaneous splenosis was examined in a preliminary study involving 5 animals by introducing unattached spleen meal and fragments. Scanning was repeated 4 to 12 weeks postoperatively. The functional competence of minor parenchymal islands was also investigated with well counter measurements of organ and muscle tissue homogenates. Spontaneous splenosis after abdominal injuries was not found to be the rule. Salvaging procedures at the natural vascular hilus by sutures, fibrin ...

37

Analysis of Elements in The Baltic Sea Sediment by Using Gamma Spectrometry  

International Nuclear Information System (INIS)

We have done analysis of elements in the Baltic sea sediment by using gamma spectrometry in neutron activation analysis Goal of the analysis is to determine the rate of morsel elements which is contained in the Baltic sea sediment. Sample of the Baltic sea Sediment (IAEA-SED-1), Standard of Reference Material (SRM) 1646 Estuarine Sediment and Standard Ce, Fe, Sc, and Co are put into vial of capsule rabbit, then irradiated together for 30 minutes in rabbit facility Multi Purpose Reactor at power of 25 MW and then cooled for one week. Next sample, standard, and SRM which have irradiated, each is cut for 30 minutes using gamma spectrometer. Result of analysis of rate of elements Ce, Fe, Sc and Co in the baltic sea sediment successively equal to 141.20 ppm, 5.91 %, 14.88 ppm, and 19.59 ppm. Result of analysis in SRM Estuarine sediment successively equal to 96.60 ppm, 3.21 %, 10.25 ppm, and 9.63 ppm. Result of this analysis if ...

2007-04-01

38

Cloning and sequencing of cDNA encoding human DNA topoisomerase II and localization of the gene to chromosome region 17q21-22  

Energy Technology Data Exchange (ETDEWEB)

Two overlapping cDNA clones encoding human DNA topoisomerase II were identified by two independent methods. In one, a human cDNA library in phage {lambda} was screened by hybridization with a mixed oligonucleotide probe encoding a stretch of seven amino acids found in yeast and Drosophila DNA topoisomerase II; in the other, a different human cDNA library in a {lambda}gt11 expression vector was screened for the expression of antigenic determinants that are recognized by rabbit antibodies specific to human DNA topoisomerase II. The entire coding sequences of the human DNA topoisomerase II gene were determined from these and several additional clones, identified through the use of the cloned human TOP2 gene sequences as probes. Hybridization between the cloned sequences and mRNA and genomic DNA indicates that the human enzyme is encoded by a single-copy gene. The location of the gene was mapped to chromosome 17q21-22 by in ...

1988-10-01

39

The effect of oxygen and paraquat on the "1"4C-glucose oxidation of rabbit alveolar macrophages and lung slices  

International Nuclear Information System (INIS)

In this study, we measured the effects of different concentrations of paraquat (0,01 mM and 1,0 mM) on the 1-"1"4CO_2 and 6-"1"4CO_2 production of rabbit lung slices and isolated alveolar macrophages, in 20% and 95% oxygen phases respectively. A 95% oxygen phase induced an increase in the 6-"1"4C-glucose oxidation of control lung slices over a 3-hour period, while the increased activity of the pentose pathway over the first 2 hours started to decline during the third hour of incubation. Paraquat (1,0mM) in 20% oxygen caused a consistent increase in the 6-"1"4CO_2 production by lung slices, but in a 95% oxygen phase gradually inhibited the 6-"1"4C-glucose oxidation over a period of 3 hours. The pentose phosphate pathway was highly significantly stimulated by 1,0 mM paraquat in 20% and 95% oxygen over 3 hours. When isolated alveolar macrophages (viability 95%) were incubated in a 20% and 95% oxygen phase respectively, both the 6-"1"4C-glucose and ...

40

Tuberculous Granulomas Are Hypoxic in Guinea Pigs, Rabbits, and Nonhuman Primates?  

UK PubMed Central (United Kingdom)

Understanding the physical characteristics of the local microenvironment in which Mycobacterium tuberculosis resides is an important goal that may allow the targeting of metabolic processes...Full Text Available

2008-06-01

42

On the stability of Innovar, a neuroleptic analgesic, for cardiovascular experiments.  

Science.gov (United States)

The effects of 0.2 and 0.5 mL/kg Innovar (a neuroleptic analgesic) on cardiovascular functions and reflexes in rabbits were measured. We recorded the effects of Innovar on arterial pressure, heart rate, respiration rate, ventricular contractility, arterial oxygen tension, as well as the drug's effects on the bradycardia and vasoconstrictor response to cigarette smoke stimulation of the nose (the so-called "nasopharyngeal reflex"). In animals given 0.2 mL/kg Innovar, all steady state cardiovascular variables had returned to pre-Innovar levels in 45 min, as had the efficacy of the nasopharyngeal reflex. In animals given 0.5 mL/kg Innovar, all steady state cardiovascular variables, except PaO2, were slightly but significantly depressed for up to 135 min after injection. The nasopharyngeal reflex returned to normal within 90 min. Because of the calmative and analgesic effects of Innovar, and its only moderate effects on cardiovascular functions and ...

1981-11-01

43

Nuclear Reactor Sharing Program  

Energy Technology Data Exchange (ETDEWEB)

The Ohio State University Research Reactor (OSURR) is licensed to operate at a maximum power level of 500 kW. A pool-type reactor using flat-plate, low enriched fuel elements, the OSURR provides several experimental facilities including two 6-inch i.d. beam ports, a graphite thermal column, several graphite-isotope-irradiation elements, a pneumatic transfer system (Rabbit), various dry tubes, and a Central Irradiation Facility (CIF). The core arrangement and accessibility facilitates research programs involving material activation or core parameter studies. The OSURR control room is large enough to accommodate laboratory groups which can use control instrumentation for monitoring of experiments. The control instrumentation is relatively simple, without a large amount of duplication. This facilitates opportunities for hands-on experience in reactor operation by nuclear engineering students making reactor parameter measurements. For neutron ...

1994-09-01

44

Changes in the Lung Lipids of Rabbits and Guinea-pigs Exposed to the Inhalation of Silica Dust  

UK PubMed Central (United Kingdom)

Eight rabbits and 24 guinea-pigs were exposed to a silica dust cloud of about 40,000 pp./ml. (0·3-3·0 μ) and killed at four-weekly intervals up to 30 weeks. The guinea-pigs showed...Full Text Available

1960-01-01

45

A methodological review of resilience measurement scales  

UK PubMed Central (United Kingdom)

BackgroundThe evaluation of interventions and policies designed to promote resilience, and research to understand the determinants and associations, require reliable and valid measures...Full Text Available

46

Development of ultrasonic measurement technique for the determination of vertical two-phase flow pattern  

Energy Technology Data Exchange (ETDEWEB)

In the present study, a new measurement technique which uses a ultrasonic transmission signals in order to determine the vertical two phase flow pattern even under high pressure condition. The ultrasonic measurement system developed in the present study not only provides the measurement functions required for the determination of vertical two phase flow pattern but also makes the real time determination possible. The developed ultrasonic measurement system accurately determined the various vertical two phase flow patterns such as bubbly, slug, churn, annular flow etc. In addition to the determination of flow patterns, qualitative informations for each flow pattern can be obtained, which include void fraction in bubbly flow, length of slug bubble and liquid tail characteristics in slug flow, and ...

2002-03-01

47

Superconducting properties of metallic superlattices  

Energy Technology Data Exchange (ETDEWEB)

The preparation by sputtering of artificial metallic superlattices is described, as are the results of x-ray structural determinations. Tunneling and resistivity measurements on these materials are reported.

1987-01-01

48

Method for determining the concentration of atomic species in gases and solids  

Energy Technology Data Exchange (ETDEWEB)

Method for determining the concentration of atomic species in gases and solids. Measurement of at least two emission intensities from a species in a plasma containing the species after a sufficient time period has elapsed after the generation of the plasma and during a second time period, permits an instantaneous temperature to be established within the sample. The concentration of the atomic species to be determined is then derived from the known emission intensity of a predetermined concentration of that species in the sample at the measured temperature, a quantity which is measured prior to the determination of the unknown concentration, and the actual measured emission from the unknown species, or by this latter emission and the emission intensity of a species having known concentration within the sample.

1999-01-01

49

Cleaning Aged EPDM Rubber Roofing Membrane Material for ...  

Science.gov (United States)

... 5. The results of the bond strength measurements were compared to the surface cleanness of the aged EPDM as determined by the specified ...

1992-08-01

50

A qualitative evaluation of radionuclide concentrations in Hanford Site Wildlife, 1983 through 1992  

Energy Technology Data Exchange (ETDEWEB)

Environmental monitoring has been conducted at the U.S. Department of Energy`s (DOE`s) Hanford Site in southeastern Washington State since 1945. Fish and wildlife have been monitored since 1945, however, a major emphasis on mammals did not occur until the 1970s. This report focuses on the 10-year period from 1983 through 1992. The objectives of this report are to evaluate {sup 90}Sr and {sup 137}Cs concentrations in Site wildlife populations and, when possible, evaluate trends in concentrations over this period of time. No distinct trends in radionuclide concentrations were apparent in most species sampled. Many measurements were at or below the analytical limit of detection. This evaluation found that concentrations of {sup 90}Sr in rabbit and deer bone were elevated in animals collected from areas adjacent to industrialized areas. Similarly, radionuclide concentrations in duck muscle from waterfowl collected at B Pond were elevated with {sup ...

1994-10-01

51

Effect of host nutrition on immunity and local immune response of rabbits to Obeliscoides cuniculi  

International Nuclear Information System (INIS)

In a series of experiments carried out on young and adult rabbits the effect of isocaloric low protein diets containing 4% or 8% protein compared with a diet containing 21% protein on Obeliscoides cuniculi infection was studied. The pathogenesis, resistance and local immunity were assessed after single infections with 10,000 larvae or reinfection with 5000 larvae. Live weight gain was reduced in young and adult rabbits fed the low protein diets, but the establishment of parasites was not substantially influenced by protein deprivation. However, development of worms in the histotrophic phase and parasite fecundity were impaired in association with the low protein diet. Moreover, mild anaemia as well as changes in the mucosal immune response as a result of infection were related to the level of dietary protein. (author). 30 refs, 6 figs, 5 tabs.

1987-05-11

52

Indoor radon concentration measurements by using SSNTD  

International Nuclear Information System (INIS)

In this paper, some results of the indoor radon concentration measurements are presented. Kodac track detectors LR 115, bare and in a cup were used for these measurements. Average winter/summer ratio was determined for the town of interest. (author). 5 refs, 1 fig., 1 tab.

53

Indoor radon concentration measurements  

International Nuclear Information System (INIS)

Some results of the indoor radon measurements are presented in this paper. Kodac track detectors LR-115 were used for these measurements. Average winter/spring ratio for indoor radon concentration was determined from the results obtained and is presented in this paper. (author).

54

Determining nuclear morphology using an improved angle-resolved low coherence interferometry system  

Science.gov (United States)

We outline the process for determining the morphology of subsurface epithelial cell nuclei using depth-resolved light scattering measurements. The measurements are accomplished using a second generation angle-resolved low coherence interferometry system. The new system greatly improves data acquisition and analysis times compared to the initial prototype system. The calibration of the new system is demonstrated in scattering studies to determine the size distribution of polystyrene microspheres in a turbid sample. The process for determining the size of cell nuclei is discussed by analyzing measurements of basal cells in a sub-surface layer of intact, unstained epithelial tissue.

2003-12-01

55

Tissue distribution of brain-thymus shared antigens recognized by anti-brain xenosera in the rat, dog and man.  

UK PubMed Central (United Kingdom)

A comparative and quantitative study of the tissue distribution of brain-thymus shared antigens was carried out using rabbit antisera to rat, dog and human brain homogenates, assayed on rat, dog and...Full Text Available

1979-03-01

56

The reactivity of thiol groups and the subunit structure of aldolase  

UK PubMed Central (United Kingdom)

1. Seven unique carboxymethylcysteine-containing peptides have been isolated from tryptic digests of rabbit muscle aldolase carboxymethylated with iodo[2-14C]acetic acid in 8m-urea....Full Text Available

1970-04-01

57

The metabolism of the isomeric decalones  

UK PubMed Central (United Kingdom)

1. The metabolism of (±)-cis-1-, (±)-trans-1-, (±)-cis-2- and (±)-trans-2-decalone in the rabbit...Full Text Available

1966-08-01

58

Taloximine, a new respiratory stimulant with bronchodilator properties  

UK PubMed Central (United Kingdom)

1. A novel phthalazine analogue taloximine (1-hydroxyimino-4(2-dimethyl-aminoethoxy)-1,2-dihydrophthalazine monohydrochloride monohydrate) stimulated respiration in conscious rabbits at doses of 7...Full Text Available

1969-02-01

59

Some aspects of the pharmacology of an homologous series of choline esters of fatty acids  

UK PubMed Central (United Kingdom)

The pharmacological effects of a series of fatty acid-choline esters have been studied on the isolated rabbit heart, the isolated guinea-pig ileum and the rat stomach. The effect changed with increasing...Full Text Available

1957-03-01

60

Role of the sar locus of Staphylococcus aureus in induction of endocarditis in rabbits.  

UK PubMed Central (United Kingdom)

A regulatory locus on the Staphylococcus aureus chromosome, designated sar, is involved in the expression of cell wall proteins, some of which are potentially important in the pathogenesis of endocarditis....Full Text Available

1994-05-01

61

Regulation of hyaluronan secretion into rabbit synovial joints in vivo by protein kinase C  

UK PubMed Central (United Kingdom)

Hyaluronan (HA) is important for joint cavitation, lubrication, volume regulation and synovial fluid drainage but little is known about the regulation of joint HA synthesis/secretion in vivo....Full Text Available

2003-07-15

62

Pathway to Licensure for Protective Antigen-based Anthrax Vaccines ...  

Science.gov (United States)

... Weiss, S., D. Kobiler, H. Levy, H. Marcus, A. Pass, N. Rothschild, and Z ... of Bacillus anthracis spores conferred by a protective antigen-based vaccine in rabbits ...

63

Naturally occurring double-stranded RNA and immune responses. III. Immunogenicity and antigenicity in animals.  

UK PubMed Central (United Kingdom)

Naturally occurring, double-stranded RNA (ds-RNA)) was immunogenic when injected into mice, rats, guinea-pigs, rabbits, dogs and baboons. The response to native material administered intravenously (i.v.)...Full Text Available

1975-12-01

64

Molecular and immunological comparison of human dihydropteridine reductase in liver, cultured fibroblasts and continuous lymphoid cells.  

UK PubMed Central (United Kingdom)

An antiserum was raised in a rabbit against highly purified human liver dihydropteridine reductase (EC 1.6.99.7). Dihydropteridine reductase from human liver, in human cultured fibroblasts and in continuous...Full Text Available

1981-07-01

65

Location of an epitopic site on epiglycanin by molecular immunoelectron microscopy.  

UK PubMed Central (United Kingdom)

Antibodies of the IgM type present in rabbit anti-epiglycanin antiserum were purified by (NH4)2SO4 precipitation and by ion-exchange, affinity and gel-filtration chromatography. After papain treatment...Full Text Available

1985-04-01

66

INTRAVITREAL HUMAN IMMUNE GLOBULIN IN A RABBIT MODEL OF STAPHYLOCOCCUS AUREUS TOXIN-MEDIATED ENDOPHTHALMITIS: A POTENTIAL ADJUNCT IN THE TREATMENT OF ENDOPHTHALMITIS  

UK PubMed Central (United Kingdom)

ABSTRACTObjectivesTo test the feasibility of human immune globulin (IG, Gamimune N, 10%) as a new treatment for endophthalmitis, the ocular tolerance, distribution,...Full Text Available

2004-12-01

67

Head position modulates optokinetic nystagmus  

UK PubMed Central (United Kingdom)

Orientation and movement relies on both visual and vestibular information mapped in separate coordinate systems. Here, we examine how coordinate systems interact to guide eye movements of rabbits....Full Text Available

2011-08-01

68

GNF - Wilson Inlet  

Wastenet

... The costal plain still supports Jarrah (Eucalyptus marginata ) forest, dense woodlands, coastal heath and diverse swamplands. Many species of plants are endemic. 20 species of mammals and 12 species of introduced mammals including with feral pigs, rabbits and foxes of particular concern....

69

GAMMA GLOBULIN METABOLISM IN RABBITS DURING THE ANAMNESTIC RESPONSE.  

Science.gov (United States)

1. Gamma globulin metabolism and distribution were studied employing rabbit gamma globulin (RGG)I(131) 24 times in 13 control rabbits. Similar studies were performed before and during the ananmestic response in 4 rabbits previously sensitized with a polyvalent pneumococcal vaccine. 2. During the ananmestic response, gamma-globulin levels increased from 1.0 to 6.0 gm/100 ml, and the gamma-globulin pool increased from 0.7 to 4.7 gm/kg. There was no change in the intravascular-extravascular partition of gamma globulin. 3. Gamma globulin degradation increased from 0.06 to 0.33 gm/kg/day during the 28 days of the immunization period while gamma globulin synthesis increased even further to average 0.47 gm/kg/day. Following the attainment of elevated gamma globulin levels the fractional rate of RGG-I(131) turnover increased from 8.0 to 12.5 per cent/day. 4. No differences were noted in the metabolism of homologous or autologous ...

1964-04-01

70

Fourier Transform Infrared Imaging and MR Microscopy Studies Detect Compositional and Structural Changes in Cartilage in a Rabbit Model of Osteoarthritis  

UK PubMed Central (United Kingdom)

Assessment of subtle changes in the primary macromolecular components of cartilage, proteoglycan (PG) and collagen, is critical for the diagnosis of early stages of osteoarthritis (OA), but...Full Text Available

2007-03-01

71

Effect of 9-(2-Hydroxyethoxymethyl)guanine on Herpesvirus-Induced Keratitis and Iritis in Rabbits  

UK PubMed Central (United Kingdom)

Drugs used for the inhibition of DNA viruses, such as iododeoxyuridine, adenine arabinoside, or trifluorothymidine, are not biochemically selective in their action and also interfere with normal cellular...Full Text Available

1978-12-01

72

EFFECT OF AGE ON THE ROLE OF RHO-KINASE IN SHORT TERM PARTIAL BLADDER OUTLET OBSTRUCTION  

UK PubMed Central (United Kingdom)

ObjectivesWe examined the expression of Rho Kinase (ROK) isoforms in young and old rabbit’s detrusor smooth muscles (SM) during the progression of short term...Full Text Available

2008-03-01

73

Changes in Rabbit and Cow Lens Shape and Volume upon Imposition of Anisotonic Conditions  

UK PubMed Central (United Kingdom)

In vivo, mammalian lenses have the capacity to effect fully reversible changes in shape, and possibly volume, during the accommodation process. Isolated lenses also change shape...Full Text Available

2009-10-01

74

Cerebellar cell surface antigens of mouse brain.  

UK PubMed Central (United Kingdom)

Reaggregated cells from 6- to 8-day-old mouse cerebella have been used to raise antibodies in rabbits. The interaction of these antibodies with cerebellar cell surface components was assessed by cytotoxicity...Full Text Available

1975-10-01

75

Biosynthesis and characterization of rabbit tooth enamel extracellular-matrix proteins.  

UK PubMed Central (United Kingdom)

Tooth enamel biomineralization is mediated by enamel proteins synthesized by ameloblast cells. Two classes of proteins have been described: enamelins and amelogenins. In lower vertebrates the absence...Full Text Available

1988-05-01

76

Antigenic analysis of the second extra-cellular loop of the human beta-adrenergic receptors.  

UK PubMed Central (United Kingdom)

Polyclonal antibodies were raised in rabbits by immunization with free peptides corresponding to positions 197-222 of the human beta 1-adrenergic receptor (beta 1 peptide) and the corresponding sequence...Full Text Available

1989-10-01

77

Placental transfer of 14C-hexoprenaline. [Rabbits  

Energy Technology Data Exchange (ETDEWEB)

The placental transfer of a single intravenous injection of 14C-hexoprenaline was studied in eight pregnant New Zealand white rabbits. Maternal and fetal blood was sampled intermittently for 60 minutes after the injection. An initial rapid decrease in the levels of 14C-hexoprenaline in maternal blood was followed by a second slower phase, whereas fetal levels remained insignificant. The conclusion, therefore, is that the rapid improvement in fetal heart rate after the administration of a single maternal intravenous injection of hexoprenaline in the treatment of fetal distress is due to the action on the uterus and/or on maternal cardiovascular function, and not to direct stimulation of the fetus.

1982-02-01

78

Self-expandable stent loaded with {sup 125}I seeds: Feasibility and safety in a rabbit model  

Energy Technology Data Exchange (ETDEWEB)

Objective: To evaluate technical feasibility and acute and subacute radiotolerance of a self-expandable stent loaded with {sup 125}I seeds in the rabbit esophagus. Methods: A self-expandable stent designed for esophageal application was made of 0.16 mm nitinol wire and loaded with {sup 125}I seeds (CIAE-6711). Twenty-seven stents with three different radioactive dosages (n = 9 in each dosage group) were implanted in the esophagus of healthy rabbits, while nine stents alone were used as controls. The stents were perorally deployed into the esophagus under fluoroscopic guidance. Radiological follow-up included plain chest film, CT scan, and barium esophagography which were undertaken in all rabbits of each group at 2, 4, and 8 weeks, respectively, which were correlated to histopathological findings. The stented esophageal segments along with their adjacent tissues were harvested for histopathological examinations. Results: ...

2007-02-15

79

Shock compression temperature rise determined from resistivity of embedded metal foils. [Polymethyl methacrylate  

Energy Technology Data Exchange (ETDEWEB)

The temperature rise induced by shock compression of polymethyl methacrylate (PMMA) was determined from measurements of the electrical resistivity of embedded copper foils. The temperature of the copper was determined from the observed foil resistance and known values of the change in copper resistivity with temperature and shock compression. Temperature values obtained over a stress range from 0.9 to 6.0 GPa are in good agreement with thermocouple measurements reported previously.

1980-01-01

80

cDNA sequence analysis of a 29-kDa cysteine-rich surface antigen of pathogenic Entamoeba histolytica  

Energy Technology Data Exchange (ETDEWEB)

A {lambda}gt11 cDNA library was constructed from poly(U)-Spharose-selected Entamoeba histolytica trophozoite RNA in order to clone and identify surface antigens. The library was screened with rabbit polyclonal anti-E. histolytica serum. A 700-base-pair cDNA insert was isolated and the nucleotide sequence was determined. The deduced amino acid sequence of the cDNA revealed a cysteine-rich protein. DNA hybridizations showed that the gene was specific to E. histolytica since the cDNA probe reacted with DNA from four axenic strains of E. histolytica but did not react with DNA from Entamoeba invadens, Acanthamoeba castellanii, or Trichomonas vaginalis. The insert was subcloned into the expression vector pGEX-1 and the protein was expressed as a fusion with the C terminus of glutathione S-transferase. Purified fusion protein was used to generate 22 monoclonal antibodies (mAbs) and a mouse polyclonal antiserum specific for the E. histolytica portion ...

1990-08-01

81

cDNA sequence analysis of a 29-kDa cysteine-rich surface antigen of pathogenic Entamoeba histolytica  

International Nuclear Information System (INIS)

A #lambda#gt11 cDNA library was constructed from poly(U)-Spharose-selected Entamoeba histolytica trophozoite RNA in order to clone and identify surface antigens. The library was screened with rabbit polyclonal anti-E. histolytica serum. A 700-base-pair cDNA insert was isolated and the nucleotide sequence was determined. The deduced amino acid sequence of the cDNA revealed a cysteine-rich protein. DNA hybridizations showed that the gene was specific to E. histolytica since the cDNA probe reacted with DNA from four axenic strains of E. histolytica but did not react with DNA from Entamoeba invadens, Acanthamoeba castellanii, or Trichomonas vaginalis. The insert was subcloned into the expression vector pGEX-1 and the protein was expressed as a fusion with the C terminus of glutathione S-transferase. Purified fusion protein was used to generate 22 monoclonal antibodies (mAbs) and a mouse polyclonal antiserum specific for the E. histolytica portion ...

82

Species comparison of acute inhalation toxicity of ozone and phosgene  

Energy Technology Data Exchange (ETDEWEB)

A comparison of the concentration-response effects of inhaled ozone (O/sub 3/) in different species of laboratory animals was made in order to better understand the influence of the choice of species in inhalation studies of this gas. The effect of 4-hour exposure to ozone (O/sub 3/) at concentrations of 0.0, 0.2, 0.5, 1.0, and 2.0 ppm was determined in rabbits, guinea pigs, rats, hamsters and mice. Lavage fluid protein (LFP) accumulation 18 hr after exposure was used as the indicator of O/sub 3/-induced pulmonary edema. All species had similar basal levels of LFP (250-350 ug/ml) when a volume of saline which approximated the total lung capacity was used for lavage of the collapsed lungs. Exponential dose-response curves were seen in all species except guinea pigs, which showed significant increases in LFP at low O/sub 3/ concentrations (0.2 ppm) and a leveling off of response at the higher O/sub 3/ levels. Other species usually showed ...

1986-01-01

83

Quantitative pharmacological analysis of 2-125I-iodomelatonin binding sites in discrete areas of the chicken brain  

Energy Technology Data Exchange (ETDEWEB)

The authors have localized and characterized 2-125I-iodomelatonin binding sites in the chicken brain using in vitro quantitative autoradiography. Binding sites were widely distributed throughout the chicken brain, predominantly in regions associated with the visual system. The specific binding of 2-125I-iodomelatonin to discrete chicken brain areas was found to be saturable, reversible, and of high affinity. The specific binding of 2-125I-iodomelatonin (75 pm) was quantitated for 40 identifiable brain regions. Eight brain regions were chosen for binding characterization and pharmacological analysis: optic tectum, Edinger-Westphal nucleus, oculomotor nucleus, nucleus rotundus, ventral supraoptic decussation, ventrolateral geniculate nucleus, neostriatum, and ectostriatum. These regions showed no rostral-caudal gradient in 2-125I-iodomelatonin specific binding, and saturation analysis revealed a single class of high-affinity sites with KD values in the range of 33-48 pM and receptor site ...

1991-09-01

84

MHC-like molecules in some nonmammalian vertebrates can be detected by some cross-reactive xenoantisera.  

DEFF Research Database (Denmark)

Rabbit antisera raised to human and chicken MHC molecules were used to immunoprecipitate cross-reactive molecules from biosynthetically and cell surface-labeled spleen and/or blood cells of representative vertebrate species. Five major points emerged: 1) There were many nonspecific cross-reactions using these techniques, so various criteria were developed to distinguish these from true MHC-like molecules. 2) Only very small subpopulations of immunogen-specific antibodies cross-reacted with MHC-like molecules in other nonmammalian species. These subpopulations were different for each species and even within a species, sometimes being so limited as to behave like alloantisera. This led to a very scattered pattern of true cross-reactions that sometimes failed to reflect the properties of the bulk antibody population. 3) Antisera containing antibodies to class II beta- and class I alpha-chains cross-reacted better and more widely than those to B-G, class II alpha and, ...

1990-01-01

85

A single amino acid substitution (R441A) in the receptor-binding domain of SARS coronavirus spike protein disrupts the antigenic structure and binding activity  

International Nuclear Information System (INIS)

The spike (S) protein of severe acute respiratory syndrome coronavirus (SARS-CoV) has two major functions: interacting with the receptor to mediate virus entry and inducing protective immunity. Coincidently, the receptor-binding domain (RBD, residues 318-510) of SAR-CoV S protein is a major antigenic site to induce neutralizing antibodies. Here, we used RBD-Fc, a fusion protein containing the RBD and human IgG1 Fc, as a model in the studies and found that a single amino acid substitution in the RBD (R441A) could abolish the immunogenicity of RBD to induce neutralizing antibodies in immunized mice and rabbits. With a panel of anti-RBD mAbs as probes, we observed that R441A substitution was able to disrupt the majority of neutralizing epitopes in the RBD, suggesting that this residue is critical for the antigenic structure responsible for inducing protective immune responses. We also demonstrated that the RBD-Fc bearing R441A mutation could not bind to soluble and ...

2006-05-26

86

Non-destructive measurement of corrosion effects on high temperature coatings  

Energy Technology Data Exchange (ETDEWEB)

Non-destructive methods for measuring the remaining anticorrosive or antioxidative ability of coatings are investigated. For anticorrosive chromium coatings the increasing ferromagnetism caused by loss of chromium is measured by a permeability probe. Measured values on blades after operation are correlated with the progress of corrosion as determined by metallographic methods. For antioxidative aluminum coatings the diminishing layer thickness is taken as indication for the exhaustion of their protection ability. The layer thickness is measured eddy current probes, especially developed for this application.

1990-01-01

87

Method of Determining Hail Coverage with an Airborne Infrared Thermometer.  

Science.gov (United States)

The fraction of a given area of ground that is covered by hail can be determined by using an airborne infrared thermometer. If the ambient ground temperature and the hail-covered ground temperature are measured with the same thermometer, and the surface o...

1970-01-01

88

166Ho-HA evaluation as therapeutic agent for rheumatoid arthritis treatment  

International Nuclear Information System (INIS)

Aim: Rheumatoid arthritis is a limiting disease having, among its pathological features, the inflammation of synovial tissue with progressive and later destruction of the articulation. This leads to joint deformation and loss of its function, generating pain and reducing the mobility of the affected articulation. The aim was to evaluate "1"6"6Ho-Hydroxyapatite ("1"6"6 Ho-HA) as potential radiopharmaceutical for the symptomatic treatment of chronic and acute arthritis. Materials and Methods: Holmiun-166 was produced by irradiation of Ho_2O_3 at La Reina Research Reactor, Nuclear Chilean Energy Commission. Hydroxyapatite was in-house synthesized. Its labelling and quality controls follows the internationally accepted procedures. An antigen's arthritis was induced to eight New Zealand rabbits with the "1"6"6 Ho-HA radiochemical being administered thereafter in two dosage modalities (single and double). The compound therapeutic efficiency was evaluated based upon ...

2002-09-01

89

Radon measurements in dwellings using activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

In Sweden there is a demand for a method of measuring radon in dwellings with high accuracy and at a low cost. A method of determining radon concentration (Bq.m/sup -3/) in dwellings has been developed at the Swedish National Testing Institute. A plastic canister containing activated charcoal has been tested in a radon chamber (volume 20 m/sup 3/) to determine the effects of relative humidity, temperature and exposure time. The activated charcoal in the canister adsorbs radon from the air surrounding the canister. The radon concentration is determined by counting the gamma rays from the decay of radon and daughters. The theory and preliminary results from calibrations and field measurements are reported.

1984-01-01

90

Accurate determination of detection efficiency and self-absorption factors in measuring radon daughter  

International Nuclear Information System (INIS)

The detection efficiency of #alpha# particles of "2"1"4Po 7.69 MeV and "2"1"8Po 6.00 MeV in measuring radon daughters were determined through the data which were measured with long-lived #alpha# standard source and radon daughter standard source and with curve-fitting method of general formulation. The indeterminacy was #<=#2.5% and #<=#2.7% respectively. Their ranges in filter membrane were also determined, and the effect of the indeterminacy on the self-absorption factors was #<=#1.3%.

91

The effect of semantic set size on word learning by preschool children  

UK PubMed Central (United Kingdom)

PurposeThe purpose was to determine whether semantic set size, a measure of the number of semantic neighbors, influenced word learning, and whether the influence...Full Text Available

2009-04-01

92

Study of B --> pi l nu and B --> rho l nu decays and determination of |Vub| at BaBar  

CERN Document Server

We report a measurement of the branching fractions for $B^{0} \\rightarrow \\pi^- \\ell^+\

2010-01-01

93

Spatial Relationships between Drug Binding Sites on the ...  

Science.gov (United States)

... determination of the molar extinction coefficients, e, were measured by the Lowry method with native a-toxin as a standard. Binding Kinetics. ...

1987-10-15

94

Phase-Sensitive Fluorescence Study of Mono-L-Aspartyl ...  

Science.gov (United States)

... of perylene were measured with the Shimadzu UV-2500 UV-VIS spectrophotometer (Kyoto, Japan) to determine their molar extinction coefficients. ...

2001-10-25

95

Determination of radiation exposure and significance of its influential factors for X-rayed children in the GDR  

International Nuclear Information System (INIS)

After having discussed the peculiarities of children in X-ray diagnosis the application of the effective as well as the mean equivalent doses as to the determination of the radiation exposure in children is represented. In using computerized tomograms to determine position and extent of an organ the exposure by repeated X-raying was calculated referring to the entrance dose. Entrance dose measurements for all types of X-ray examination in hospitals and ascertainments of the frequency of radiograms in 20 X-ray departments were used to determine per capita and collective doses, resp., in several age groups. Alltogether, the per capita dose of children in the GDR amounts to 30% of that of adults. Conclusions were drawn as to taking measures to further reduction of radiation exposure: (1) Technical measures, such as positioning of patients, shielding of organs, ...

1988-01-01

96

Comparison of methods to determine accurate dose calibrator activity measurements  

UK PubMed Central (United Kingdom)

BackgroundIn nuclear medicine, liquid radiopharmaceuticals for diagnostic or therapeutic purposes are administered to patients by using various types of syringes with different volumes....Full Text Available

97

Measuring quality of care in psychiatric emergencies: construction and evaluation of a Bayesian index.  

UK PubMed Central (United Kingdom)

OBJECTIVE. This study was conducted to determine whether an index for measuring quality of care for psychiatric emergencies is reliable and valid. DATA SOURCES/STUDY SETTING. The study used primary...Full Text Available

1993-06-01

98

Interrater Reliability of Isokinetic Measures of Knee Flexion and Extension  

UK PubMed Central (United Kingdom)

The purpose of this investigation was to determine the interrater reliability of peak torque and total work values obtained with isokinetic measures of knee flexion and extension. Eight male and eight...Full Text Available

1995-06-01

99

Two and 8-azido photoaffinity probes. 1. Enzymatic synthesis, characterization, and biological properties of 2- and 8-azido photoprobes of 2-5A and photolabeling of 2-5A binding proteins  

International Nuclear Information System (INIS)

The 2- and 8-azido trimer 5'-triphosphate photoprobes of 2-5A have been enzymatically synthesized from [#gamma#-"3"2P]2-azidoATP and [#alpha#-"3"2P]8-azidoAPT by 2-5A synthetase from rabbit reticulocyte lysates. Identification and structural determination of the 2- and 8-azido adenylate trimer 5'-triphosphates were accomplished by enzymatic hydrolyses with T2 RNase, snake venom phosphodiesterase, and bacterial alkaline phosphatase. Hydrolysis products were identified by HPLC and PEI-cellulose TLC analyses. The 8-azido photoprobe of 2-5A displaces p_3A_4["3"2P]pCp from RNase L with affinity equivalent to p_3A_3. The 8-azido photoprobe also activates RNase L to hydrolyze poly(U)["3"2P]pCp 50% at 7 /times/ 10/sup /minus/9/ M in core-cellulose assays. The 2- and 8-azido photoprobes and authentic p_3A_3 activate RNase L to cleave 28S and 18S rRNA to specific cleavage products at 10/sup /minus/9/ M in rRNA cleavage assays. The nucleotide binding ...

100

Wear measurements at railway wheel treads and brake discs with the radiometric thin-layer difference method  

International Nuclear Information System (INIS)

The investigation of important wear processes in the railway technique, especially the differentiation of the parameters influencing the wear process, requires extensive test programmes and thus high resolving methods to determine the wear. Radiometric methods enable considerably greater measuring accuracy with the help of the activation of materials than an observation of measurement or measuring changes. (orig./LH).

1975-04-03

101

Absolute absorption of ozone in the midinfrared  

Energy Technology Data Exchange (ETDEWEB)

The absolute absorption of ozone in the midinfrared has been measured relative to 253.7-nm ultraviolet absorption to an accuracy of 1% using a Bruker Fourier transform spectrometer. These new results agree with previous measurements by diode laser measurements after the latter are corrected for more recent infrared calculations and ultraviolet cross sections. They also agree with a determination based on refractive index measurements in the infrared. 16 refs., 4 figs., 3 tabs.

1992-12-20

102

Gamma absorption determination of concentration in a three-component mixture  

International Nuclear Information System (INIS)

A method for the analysis of three-component mixtures is described. The method is used for contact-free determination of component concentration in the mixtures transported via a product duct. Formulae as an aid in choosing the gamma radiation source and estimating the efficiency of measurement are given. The errors of measurement by the method of formaline-water-carbamide mixture is 1-2 %. 9 refs.; 1 fig.

103

Determining the upper limit of Gamma_{ee} for the Y(4260)  

CERN Document Server

By fitting the R values between 3.7 and 5.0 GeV measured by the BES collaboration, the upper limit of the electron width of the newly discovered resonance Y(4260) is determined to be 240 eV at 90% C.L., together with the BABAR measurement on the product of Gamma_{ee} and BR(Y(4260) --> pi+pi- J/psi), this implies a large decay width of Y(4260) --> pi+pi- J/psi final states.

2006-01-01

104

Studies on localization of calcitonin gene-related peptide (CGRP) in the thyroid-parathyroid complex.  

Science.gov (United States)

Calcitonin gene-related peptide (CGRP) was localized by an immunocytochemical technique in the thyroid-parathyroid complexes of rat, guinea pig, rabbit, and in normal human thyroids and parathyroids. Human medullary carcinomas and parathyroid adenomas were also studied. In man and all animal species examined CGRP was present in the parafollicular cell, however, in guinea pigs only in small amounts. Except in rabbits, presence of CGRP was demonstrated in nerves of the thyroid and parathyroid capsule as well as in the nerve fibers of the capsular blood vessels. In the thyroid of guinea pigs CGRP was also noted in nerve fibers and in blood vessel walls between follicles. CGRP was also present in the parathyroid glands of rat and man, in nerve fibers localized between parathyroid cells. In rabbit the parafollicular cells between parathyroid cells also expressed CGRP immunoreactivity. No CGRP was noted in the parathyroids of the ...

1987-01-01

105

Purification and partial characterization of glycosaminoglycans and proteoglycans from cultured rabbit smooth muscle cells  

Energy Technology Data Exchange (ETDEWEB)

Glycosaminoglycans synthesized by cultured rabbit smooth muscle cells were isolated after incorporation of (/sup 3/H)-glucosamine into glycosaminoglycans in the presence or absence of 10% fetal bovine serum. Glycosaminoglycans were quantitated by two-dimensional electrophoresis after proteolytic digestion of the cell layers and media. The results show that the presence of serum has no effect on the chondroitin sulfate, heparan sulfate and dermatan sulfate content of the cell layers. The incorporation of (/sup 3/H)-glucosamine into hyaluronic acid of the cell layers was three times higher in the presence of serum. In the medium , the quantity of hyaluronic was two times higher in the presence of serum while the other glycosaminoglycans remained unchanged. The incorporation of (/sup 3/H)-glucosamine into hyaluronic acid was unaffected by the presence of serum. Specific proteoglycans were isolated from medium after with (/sup 35/S)-sulfate and (/sup 3/H)-serine by ...

1985-01-01

106

A Polyhydroxybutyrate Biodegradable Stent: Preliminary Experience in the Rabbit  

International Nuclear Information System (INIS)

Purpose: The lifelong persistence of foreign bodies within the arteries may contribute to restenosis. Thus,biodegradable devices might decrease recurrence rates. Methods: Eleven polyhydroxybutyrate biodegradable stents and 13 tantalum stents were implanted into the iliac arteries of New Zealand white rabbits for up to 30 weeks. After killing the animals,the specimens were harvested, fixed in formalin, processed in paraffin,and stained. Results: Polyhydroxybutyrate instigated intense inflammatory and proliferative reactions with an increase in collagen (2.4- to 8-fold vs native segments), thrombosis and in-stentlumen narrowing (375.5-606.6 mm vs 655.6 #+-# 268.8 mm in native segments). The elastic membranes were destroyed in all specimens. The tantalum stents increased the in-stent lumen progressively (769.7 #+-# 366.6 mm vs 1309.9 #+-# 695.3 mm),penetrated the external elastic membrane, and increased mural collagen content (6- to 8.6-fold vs native segments). ...

2002-03-01

107

Determination of reactivity from power spectral density measurements with /sup 252/Cf. [LMFBR  

Science.gov (United States)

The theory of a method of determination of reactivity from power spectral density measurements with /sup 252/Cf and the results of experiments with a critical assembly mockup of a liquid-metal fast breeder reactor (LMFBR) and with uranium (93.2 wt % /sup 235/U) metal cylinders and a sphere are presented. This method of reactivity determination has an advantage over existing methods in that it determines the reactivity only from properties of the reactor at the subcritical state of interest and thus does not require a calibration near delayed criticality. In these experiments, the reactivity was varied by changing the fissile loading or the amount of neutron absorber inserted; for the LMFBR mockup, the reactivity varied to approximately 75 dollars subcritical, and for the uranium metal assemblies to approximately 30 dollars subcritical. These experiments verified for the first time the predictions of ...

1978-04-01

108

Analytical method for determination of the decontamination factor of an evaporation plant for radioactive waste water  

International Nuclear Information System (INIS)

Two inactive tracer techniques for determination of the decontamination factor (DF) of evaporation plants for radioactive waste water are described. One method was used for determination of the DF of an one stage pilot plant. The elements Mg, Cd and Co were employed as tracers. The analyses were performed by atomic absorption spectroscopy. The measurements being fast and simple are especially advantageous with test series in pilot plants. In the second method activation analysis was used for measurement of the tracer to determine the DF of a two stage evaporation plant. Europium is added to the stock solution in a concentration of 70 ppm only. With this method a DF of up to 3 . 10"8 can still be determined. (Auth.).

109

Methods and instruments for nondestructive testing of the anisotropy of the magnetic properties of ferromagnetic sheet materials (review)  

Energy Technology Data Exchange (ETDEWEB)

This review of methods and designs of transducers for nondestructive determination of the magnitude and nature of the anisotropy of magnetic properties (permeability, induction, coercive force, energy loss due to magnetization reversal) in local portions of ferromagnetic sheet and, in some cases, in individual parts of products. The need to measure the anisotropy is considered for two angles: for the case when the anisotropy is due to the crystallographic texture and determines the main operating characteristics of widely used sheet such as electrical steel and automobile body sheet, and for crystallographically isotropic materials, in which the anisotropy of magnetic properties as a result of mechanical stresses is a measure for determining the internal stresses.

1995-04-01

110

Determination of ash content in coal by means of backscattered X-ray radiation and X-ray fluorescence analysis, and devices manufactured by the PAR company  

Energy Technology Data Exchange (ETDEWEB)

Discusses methods for determining ash content in coal using backscattering in X-ray fluorescence. The following aspects are evaluated: principle of ash content determination, energy sources, factors that influence measurement accuracy, reliability. Types of X-ray fluorescence analyzers developed in Czechoslovakia and manufactured in the Czech Republic are comparatively evaluated. Operation of the RPM 113.1 radionuclide X-ray fluorescence analyzer developed by the PAR company and used for measuring ash content in coal and coal calorific value is discussed. 7 refs.

1993-09-01

111

Ocular Burn: Rinsing and Healing with Ionic Marine Solutions and Vegetable Oils  

British Library Electronic Table of Contents (United Kingdom)

Abstract Purpose: We investigated the effects of various rinsing and healing protocols on corneal wound repair and inflammation following alkali burn in rabbits. Methods: We conducted in vitro, in vivo and ex vivo studies. First, different rinse solutions were tested in vitro after incubation of ocular cells with methanol or NaOH. Cell viability was then assessed using the neutral red test (cytofluorometry). Second, NaOH was applied to rabbit corneas and associations of rinse solutions (NaCl 0.9% or controlled ionization marine solutions) with N-acetylcysteine or vegetable oils (from Calophyllum inophyllum and Aleurites moluccana) were tested in vivo. The regeneration of the corneal epithelium and the infiltration of inflammatory cells were evaluated using in vivo confocal microscopy and e...

2009-01-01

112

Hydroxyapatite coating enhances polyethylene terephthalate artificial ligament graft osseointegration in the bone tunnel  

British Library Electronic Table of Contents (United Kingdom)

The purpose of this study was to investigate whether hydroxyapatite (HAp) coating could induce polyethylene terephthalate (PET) artificial ligament graft osseointegration in the bone tunnel. Twenty-four New Zealand white rabbits underwent artificial ligament graft transplantation in bilateral proximal tibia tunnels. One limb was implanted with HAp-coated PET graft, and the contralateral limb was implanted with non-HAp-coated PET graft as control. The rabbits were randomly sacrificed at four and eight?weeks after surgery. The loads to failure of the experimental group at eight?weeks were significantly higher than those of the control group (p?=?0.0057). Histologically, application of HAp coating induced new bone formation between graft and bone at eight?weeks compared with the controls. Rea...

2011-01-01

113

Redox potential measurement in the power station  

Energy Technology Data Exchange (ETDEWEB)

By its very nature redox potential measurement is suitable for determining the concentration ratio of a stable redox pair through its interaction with a chemically inert electrode surface but not the absolute concentration of a material. The measured redox potentials agree only rarely with those which are easily calculable theoretically. No individual defined stable redox pair is available in power station water. It is therefore not simply possible to measure definable mixed potentials more precisely. For these reasons redox potential measurement in the power station, as also with other types of water, can no longer be regarded as an indicator, by which it can be established whether oxidizing or reducing materials predominate in the water.

1983-01-01

114

Redox potential measurement in the power station  

International Nuclear Information System (INIS)

By its very nature redox potential measurement is suitable for determining the concentration ratio of a stable redox pair through its interaction with a chemically inert electrode surface but not the absolute concentration of a material. The measured redox potentials agree only rarely with those which are easily calculable theoretically. No individual defined stable redox pair is available in power station water. It is therefore not simply possible to measure definable mixed potentials more precisely. For these reasons redox potential measurement in the power station, as also with other types of water, can no longer be regarded as an indicator, by which it can be established whether oxidizing or reducing materials predominate in the water. (orig.).

115

The use of different techniques for determination of pitting corrosion potential of austenitic stainless steel  

International Nuclear Information System (INIS)

Three different techniques for pitting corrosion potential measurement on austenitic stainless steel (Fe18Cr10Ni) were compared: conventional polarization method, a new Avesta electrochemical corrosion measurement cell and a scratch technique. Special attention was paid to the effects of crevice corrosion during pitting corrosion potential measurement and to their elimination. Development of a rapid test technique for reliable pitting corrosion potential determination was aimed at and resulted from comparison of the different techniques.

1991-07-01

116

Power spectral density measurements with /sup 252/Cf for unreflected 17. 77-cm-dia uranium (93. 2 wt % /sup 235/U) metal cylinders  

Science.gov (United States)

The method of reactivity determination using noise analysis correlation measurements with /sup 252/Cf was used to determine the reactivity for subcritical 17.77-cm-dia uranium (93.2 wt percent /sup 235/U) metal cylinders with reactivities as low as 25 dollars. Far subcritical tests were performed with right circular cylinders of uranium metal for which the subcritical reactivity was known from other inverse kinetics and prompt neutron decay constant measurements.

1976-01-01

117

On the determination of the dose-area product during X-ray examinations  

International Nuclear Information System (INIS)

Despite its great usefulness in the performance of the recording procedures prescribed by the X-Ray Ordinance the dose-area product is much less frequently measured for X-ray exposures than during fluorscopic examinations. The great multitude of measuring units, mainly on account of different scales of the measuring equipments themselves, is a cause of uncertainty in clinical routine and should be eliminated as far as the circumstances would permit. As the determination of the organ dose is relevant only in very few cases and does not necessarily require previous measurements of the dose-area product, these are of limited practical value in the assessment of individual radiation exposures during radiographic examinations. The measurements may, however, be very helpful in determinations of the radiation dose to the total population, if the ...

118

Some optimization measurements and parameters of a radionuclide X-ray fluorescence spectrometer  

International Nuclear Information System (INIS)

An irradiation head with sample holders is described and measurement geometry is reported. Measurements were made for optimizing the distance between the source and the sample and for optimizing the sample diameter. The optimal distance between the source and the sample does not depend on the collimator diameter. The sample diameter should not exceed 30 - 35 mm. Sensitivity and detection limits were determined for Zn, Pb and Br and calibration curves were plotted. (M.D.) 6 figs., 2 tabs., 4 refs.

1986-01-01

119

Radon concentration measurements in the soil  

International Nuclear Information System (INIS)

Radon concentration measurement in the ground can be used for the prospecting for uranium and earthquake prediction. Some results of radon concentration measurement in the soil are presented here. The moisture condensation at the detector surface can affect on the detection efficiency. Due to this problem we tested a few filter papers on water permeability. The ratio of track densities on solid state nuclear track detector (SSNTD) in the open and the closed diffusion chamber is also determined. (author)

120

Characterization of polymers for microcellular foams  

Energy Technology Data Exchange (ETDEWEB)

We have measured, by {sup 1}H and {sup 13}C nuclear magnetic resonance (NMR), the percent deuteration, the tacticity and the purity of several polymers and one solvent used in the preparation of microcellular foams. The percent deuteration was measured for polystyrene, polyacrylonitrile and polyethylene. The tacticities of polystyrene and polyacrylonitrile were determined. The purity and degradation products of polyacrylonitrile and maleic anhydride were examined. This report documents the experimental procedures and results of these measurements.

1992-03-01

121

Nuclear magnetic moment measurements through hyperfine interactions in highly stripped ions  

International Nuclear Information System (INIS)

Time-differential magnetic moment measurements on the first-excited Isup(#pi#)=2"+ states in "2"0Ne and "2"4Mg with mean lives of 1.0 and 2.1 ps, respectively are described. The lifetime of the latter state was determined simultaneously. A special detection geometry was designed to improve the experimental #gamma#-ray anisotropy measured with finite-size detectors. For "2"0Ne also a time-integral measurement with charge-state separation was performed. The necessary electronics circuitry built to perform these complicated measurements and the plunger assembly with laser interferometer are also described. A magnetic moment measurement of "2"2Ne(2_1"+) with tau=5.0 ps and transient field measurements at low and high recoil velocities are reported. A discussion of possible extensions of the techniques are given. (Auth.).

1975-09-15

122

Uteroglobin gene expression in the rabbit uterus throughout gestation and in the fetal lung. Relationship between uteroglobin and eicosanoid levels in the developing fetal lung.  

UK PubMed Central (United Kingdom)

Uteroglobin (UG) gene encodes a cytokine-like, multifunctional, antiinflammatory protein, with potent phospholipase A2-inhibitory activity. It has been suggested that during implantation this protein...Full Text Available

1995-07-01

123

TED | Profile  

Wastenet

... The dawn of Bio-Mecha and a Biomechanical Revolution May 31 2011: Hi Julian, Yes, but i dont think we would ... The dawn of Bio-Mecha and a Biomechanical Revolution May 31 2011: A BBC Documentary: All Watched Over by Machines of Loving ... The dawn of Bio-Mecha and a Biomechanical Revolution May 17 2011: Ed Boyden: A light switch for neurons is an amazing ... The dawn of Bio-Mecha and a Biomechanical Revolution May 16 2011: Thank you Meher Like Spring Rabbit, its a great contribution....

124

Molecular Characterization of a Haemaphysalis longicornis Tick Salivary Gland-Associated 29-Kilodalton Protein and Its Effect as a Vaccine against Tick Infestation in Rabbits  

UK PubMed Central (United Kingdom)

The use of tick vaccines in mammalian hosts has been shown to be the most promising alternative tick control method to current use of acaricides, which suffers from a number of limitations. However,...Full Text Available

1999-04-01

125

Lytic HSV-1 infection induces the multifunctional transcription factor Early Growth Response-1 (EGR-1) in rabbit corneal cells  

UK PubMed Central (United Kingdom)

BackgroundHerpes simplex virus type-1 (HSV-1) infections can cause a number of diseases ranging from simple cold sores to dangerous keratitis and lethal encephalitis. The interaction...Full Text Available

126

Extended amino acid sequences around the active-site lysine residue of class-I fructose 1,6-bisphosphate aldolases from rabbit muscle, sturgeon muscle, trout muscle and ox liver.  

UK PubMed Central (United Kingdom)

1. Amino acid sequences covering the region between residues 173 and 248 [adopting the numbering system proposed by Lai, Nakai & Chang (1974) Science 183, 1204-1206] were derived for trout (Salmo...Full Text Available

1979-11-01

127

Sex determination using discriminant function analysis in children and adolescents: a lateral cephalometric study  

British Library Electronic Table of Contents (United Kingdom)

The objective of this study is to test the validity of sex determination in children and adolescents using lateral radiographic cephalometry and discriminant function analysis. Fifty male and 50 female cephalograms of Taiwanese children were used (males and females with mean age of 15.52???1.38 and 15.67???1.54?years, respectively). Twenty-two cephalometric measurements were performed using computerized cephalometry. Statistical analysis shows that all measurements were sexually dimorphic (p?measurements, statistically validated and clinically relevant, were used for discriminant function analysis. A stepwise discriminant procedure selected seven of the nine variables, producing 95% accuracy in sex determination. Resubstitution classification reveals the same discriminant rat...

2010-01-01

128

Precise measurement of a focused ion beam profile  

Energy Technology Data Exchange (ETDEWEB)

The profile of focused boron ion beam (FIB) from a liquid metal ion source was determined by MOS device characteristics and resist exposure experiments. A focused boron ion beam was line-scanned into the middle of the channel region along the source to drain direction of a MOSFET, and the effective channel width is determined from electrical measurements. PMMA resist was also exposed by a line-scanned boron FIB and the developed contour was observed by a SEM. The profile of the focused boron ion beam with a diameter of around 0.2 ..mu..m was determined by these two methods and it was found to have about a 1 ..mu..m wide tail at around three orders of magnitude below the peak current density region. The profile difference between the two measurements are attributed to the boron diffusion in silicon by subsequent heat-treatments during device fabrication.

1987-06-01

129

Measurement of liquid nitrogen level by radiation  

Energy Technology Data Exchange (ETDEWEB)

The measurement of level in the liquid nitrogen vessel has been carried out by the weight conversion method using weigher or by putting directly a stick in the vessel. On a large CE tank, the pressure difference was read by manometer. These methods can not be used when the vessel does not put on the weigher or the pipe for manometer is stopped. We noticed the interaction between radiation ({gamma}-ray) and substance and applied it to determine the liquid nitrogen level. The results proved it the easy method for measurement of the level in the large CE tank. Cesium 137 ({gamma}-ray energy: 662 keV) was used as the radiation source. {gamma}-ray transmission dose was determined by GM survey meter. The liquid nitrogen level could be determined by using the change of the transmission dose with amount of liquid nitrogen. (S.Y.)

1995-07-01

130

Inferring temperature uniformity from gas composition measurements in a hydrogen combustion-heated hypersonic flow stream  

Energy Technology Data Exchange (ETDEWEB)

The application of a method for determining the temperature of an oxygen-replenished air stream heated to 2600 K by a hydrogen burner is reviewed and discussed. The purpose of the measurements is to determine the spatial uniformity of the temperature in the core flow of a ramjet test facility. The technique involves sampling the product gases at the exit of the test section nozzle to infer the makeup of the reactant gases entering the burner. Knowing also the temperature of the inlet gases and assuming the flow is at chemical equilibrium, the adiabatic flame temperature is determined using an industry accepted chemical equilibrium computer code. Local temperature depressions are estimated from heat loss calculations. A description of the method, hardware and procedures is presented, along with local heat loss estimates and uncertainty assessments. The uncertainty of the method is estimated at {+-}31 K, ...

1995-08-01

131

Genetic algorithm approach for the determination of the electrical parameters of railway traction lines  

British Library Electronic Table of Contents (United Kingdom)

The problem of electrical parameters identification in complex systems, and in particular in electric railway traction systems, is considered. Parameters are determined by an indirect approach: only the terminal variables (voltages and currents and, impedance and admittance, which can be readily calculated) are measured and the per-unit-length electrical parameters are determined using a multiconductor transmission line model of the track section under test. It will be shown that some parameters cannot be measured directly, that they are not constant with frequency and that they may depend on other external conditions. An indirect method for parameters identification is proposed through an adaptive algorithm (AA), so that the calculated terminal variables match the measured ones. The AA is...

2008-01-01

132

A method for prospecting for gas deposits  

Energy Technology Data Exchange (ETDEWEB)

The method is related to hydrodynamic methods for studying wells and may be used in the prospecting and mapping of gas and gas condensate deposits and formations. The method consits of drilling exploratory wells and measurement of the physical parameters of the stratum liquid. The piezometric levels are periodically determined simultaneously in all the observation wells during a change in the atmospheric pressure, and the presence of a remoteness of the gas deposit from the well is judged from the size of the increments in the piezometric levels intime. The determinations of the piezometric levels in the wells are conducted during an abrupt change in atmospheric pressure, for instance, during the replacement of a cyclone by an anticyclone or the reverse. The atmospheric pressure is measured by a barograph, while the piezometric levels are measured by high precision level meters or ...

1980-12-30

133

Real-time neutron radiography system performance - Measurements and methods  

Energy Technology Data Exchange (ETDEWEB)

The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme ...

1988-09-01

134

Real-time neutron radiography system performance - Measurements and methods  

International Nuclear Information System (INIS)

The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of ...

1988-01-01

135

Reactor Neutrino Experiments  

CERN Document Server

Precisely measuring $\\theta_{13}$ is one of the highest priority in neutrino oscillation study. Reactor experiments can cleanly determine $\\theta_{13}$. Past reactor neutrino experiments are reviewed and status of next precision $\\theta_{13}$ experiments are presented. Daya Bay is designed to measure $\\sin^22\\theta_{13}$ to better than 0.01 and Double Chooz and RENO are designed to measure it to 0.02-0.03. All are heading to full operation in 2010. Recent improvements in neutrino moment measurement are also briefed.

2007-01-01

136

On-line partial discharge measurements and off-line dielectric spectroscopy measurements of six 115 kV XLPE cable systems  

Energy Technology Data Exchange (ETDEWEB)

This paper reported on a study in which partial discharge (PD) measurements were performed on 6 underground transmission cable circuits to determine the effectiveness of PD measurements on fluid fill cables. The cables were between 37 and 56 years old. PD activity was detected from the terminations of H11L and H3L Cable 2. However, for cables from H3L Basin TS to Mill Street junction, PD activity was detected originating from within the main cable insulation.

2009-07-01

137

Measurement of low-energy antiproton detection efficiency in BESS below 1 GeV  

Energy Technology Data Exchange (ETDEWEB)

An accelerator experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of BESS, a balloon-borne spectrometer with a superconducting solenoid. Measured efficiencies showed good agreement with calculated ones derived from the BESS Monte Carlo simulation based on GEANT/GHEISHA. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be {+-}5%, compared with the previous estimation of {+-}15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux.

2002-08-21

138

Revisited the mathematical derivation wall thickness measurement of pipe for radiography  

Energy Technology Data Exchange (ETDEWEB)

Wall thickness measurement of pipe is very important of the structural integrity of the industrial plant. However, the radiography method has an advantage because the ability of penetrating the insulated pipe. This will have economic benefit for industry. Moreover, the era of digital radiography has more advantages because the speed of radiographic work, less exposure time and no chemical used for film development. Either the conventional radiography or digital radiology, the wall thickness measurement is using the tangential radiography technique (TRT). In case, of a large diameter, pipe (more than inches) the determination maximum penetration wall thickness must be taken into the consideration. This paper is revisited the mathematical derivation of the determination of wall thickness measurement based on tangential radiography technique (TRT). The mathematical approach used in ...

2007-07-01

139

New Measurements of the Proton Electromagnetic Form Factor Ratio at Low Q{sup 2}  

Energy Technology Data Exchange (ETDEWEB)

Polarization measurements are allowing the electric to magnetic form factor ratio of the proton to be determined with unprecedented precision. Recent results indicate that there is a large deviation from unity in the proton form factor ratio around Q{sup 2}{approx_equal}0.35 GeV{sup 2}. Furthermore, the deviation from unity is attributed to a deviation of the electric form factor from standard fits and calculations. A new, partially completed, experiment will significantly improve the existing data and will determine the presence, if any, of a narrow structure in the form factor ratio. The new measurement, combined with the expected high precision cross section measurements, will allow the extraction of individual form factors with unprecedented accuracy at low Q{sup 2}.

2009-08-15

140

High-precision Absolute Distance and Vibration Measurement using Frequency Scanned Interferometry  

CERN Document Server

In this paper, we report high-precision absolute distance and vibration measurements performed simultaneously with frequency scanned interferometry using a pair of single mode optical fibers. Absolute distance was determined by counting the interference fringes produced while scanning the laser frequency. A high-finesse Fabry-Perot interferometer(F-P) was used to determine frequency changes during scanning. Two multi-distance-measurement analysis techniques were developed to improve distance precision and to extract the amplitude and frequency of vibrations. Under laboratory conditions, a precision of 40 nm was demonstrated for an absolute distance of approximately 0.45 meters using the first analysis technique. The second analysis technique has capability to measure vibration frequencies ranging from 0.1 Hz to 100 Hz with minimal amplitude on few nanometers order without a priori ...

2004-01-01

141

A simple method for measuring the radon diffusion coefficient and exhalation rate from building materials  

International Nuclear Information System (INIS)

The widespread use of building materials with relatively high radium concentrations may increase population exposure. A method is presented for measuring effective diffusion coefficients and exhalation rates of radon from such materials. Equations for use in the experimental determination of these values are obtained theoretically. The experimental set-up consists of a container which is hermetically sealed to a slab of the building material. Nitrogen is blown through the container and then through an ionization chamber which is connected to an electrometer and X-Y plotter, and the radon concentration is measured continuously. Exhalation rates of radon from some major building materials measured by this method will be used as reference levels. The method can also be used to determine other properties such as porosity. (author).

142

Development and implementation of methods for determination of the origin of nuclear materials  

International Nuclear Information System (INIS)

The determination of the origin of seized nuclear material is important for authorities in the context of the criminal investigation, in order to return the material to its last legal owner and to help preventing any further diversion of material from this source. Origin determination is based on a complex pattern of parameters obtained through analytical measurements. The information required to determine the origin of nuclear materials may be divided into two categories: endogenous information (e.g. age or mode of production of the material) which is self-explanatory; whereas exogenous information (e.g. dimensions, surface roughness, impurities) requires a database to which the parameters can be compared. The Institute for Transuranium Elements has developed methods to determine characteristic parameters like impurities, surface roughness, or microstructural information. ...

2001-10-01

143

Determination of plutonium metal origins  

Energy Technology Data Exchange (ETDEWEB)

Forensic signatures are present in any Pu sample that can determine the sample`s origin: isotopic ratio of Pu, progeny species that grow into the sample, and contaminant species left over from incomplete purification of the Pu in fuel reprocessing. In the context of intelligence information, this can result in attribution of responsibility for the product of clandestine proliferant operations or material smuggled from existing stockpiles. A list of signature elements and what can be determined from them have been developed. Work needs to be done in converting concentrations of signature species into a quantitative forensic analysis, particularly in regard to reactor performance, but this should require only a small effort. A radiochemical analysis scheme has been developed for measuring these nuclides; more work is needed, particularly for determining fission product concentrations. A sample of Pu metal ...

1995-02-01

144

Uranium oxides. Specific surface measurement by nitrogen adsorption  

International Nuclear Information System (INIS)

Determination of the specific surface of uranium oxides: UO_2 and U_3O_8 using a simplified equation derived from the Brunauer, Emmett and Teller theory. The method is suitable for samples having a surface between 6 to 50 m"2.

145

Study on the angular. gamma gamma. -correlations for nuclei of Sr even-even isotopes  

Energy Technology Data Exchange (ETDEWEB)

The angular ..gamma gamma..-correlations for nuclei of Sr even-even isotopes with A=82, 84, 86, 88 were measured. Multipole structurs of ..gamma..-transtion series and th coefficients multipole mixing were determined.

1984-05-01

146

Study on the angular #gamma##gamma#-correlations for nuclei of Sr even-even isotopes  

International Nuclear Information System (INIS)

The angular #gamma##gamma#-correlations for nuclei of Sr even-even isotopes with a=8 82, 84, 86, 88 were measured. Multipole structurs of #gamma#-transtion series and th coefficients multipole mixing were determined.

1983-04-01

147

Selection, Training, and Control Problems in the Use of the Military Working Dog.  

Science.gov (United States)

A report is made of operant conditoning procedures used in the determination of auditory, olfactory and visual acuity measures in the German Shepherd. An account is given of a procedure for semi-automatic training of dogs to search for, detect, and object...

1974-01-01

148

Prognostic determinants for survival after resection/ablation of a large hepatocellular carcinoma  

UK PubMed Central (United Kingdom)

Background:Liver resection of large hepatocellular carcinomas (HCC), measuring at least 10 cm remains a controversial debate. Multiple studies on HCCs treated with surgical resection...Full Text Available

2009-06-01

149

Prevalence and determinants of pain and pain-related disability in urban and rural settings in southeastern Ontario  

UK PubMed Central (United Kingdom)

BACKGROUND:Canadian chronic pain prevalence estimates range from 11% to 66%, are affected by sampling and measurement bias, and largely represent urban settings.OBJECTIVES:To...Full Text Available

2006-01-01

150

Online quasi-continuous measurement of organic acids in the atmosphere  

Energy Technology Data Exchange (ETDEWEB)

The concentration of some organic acids in the atmosphere was determined using a wet effluent diffusion denuder-aerosol collector coupled with Ion Chromatography. Three organic acids and four inorganic anions were identified and quantified in the air sample, taken from the backyard of PSI. (author)

2002-03-01

151

Multiple-Bond Kinetics from Single-Molecule Pulling Experiments: Evidence for Multiple NCAM Bonds  

UK PubMed Central (United Kingdom)

The kinetic parameters of single bonds between neural cell adhesion molecules were determined from atomic force microscope measurements of the forced dissociation of the homophilic protein-protein bonds....Full Text Available

2005-11-01

152

Mortality experience in relation to a measured arsenic trioxide exposure  

UK PubMed Central (United Kingdom)

This report examines the mortality experience of 527 men who retired from a copper smelter where they were exposed to airborne arsenic trioxide. Urinary arsenic values of all plant employees were determined...Full Text Available

1977-08-01

153

Minimal distensibility of pulmonary capillaries in avian lungs compared with mammalian lungs  

UK PubMed Central (United Kingdom)

Previous physiological studies suggest that avian pulmonary capillaries behave like almost rigid tubes. We made morphometric measurements to determine the diameter of the capillaries in chicken...Full Text Available

2008-02-01

154

Method for determining the temporal response of microbial phosphate transport affinity.  

UK PubMed Central (United Kingdom)

Nutrient transport affinities of nutrient-starved microbial populations were measured as initial slopes of plots of limiting-nutrient transport rates versus extracellular limiting-nutrient concentrations....Full Text Available

1986-03-01

155

Measurement of Sexual Functioning After Spinal Cord Injury: Preferred Instruments  

UK PubMed Central (United Kingdom)

Background/Objective:To determine the utility of certain instruments to assess sexuality and fertility after SCI, an expert panel identified key areas to study and evaluated...Full Text Available

2009-06-01

156

Macular and retinal nerve fiber layer thickness in Japanese measured by Stratus optical coherence tomography  

UK PubMed Central (United Kingdom)

The purpose of this study was to determine the thickness of the macula and the retinal nerve fiber layer (RNFL) in Japanese subjects by Stratus optical coherence tomography (OCT), and to compare the...Full Text Available

2007-06-01

157

Effects of pH, Temperature, and Nutrients on Propionate Degradation by a Methanogenic Enrichment Culture  

UK PubMed Central (United Kingdom)

Enrichment cultures were used to determine the conditions promoting fastest methanogenic propionate degradation and growth by adapting the cultures to various physical and chemical conditions and measuring...Full Text Available

1987-07-01

158

Effects of Age on Optical Coherence Tomography Measurements of Healthy Retinal Nerve Fiber Layer, Macula and Optic Nerve Head  

UK PubMed Central (United Kingdom)

PurposeTo determine the effects of age on global and sectoral peripapillary retinal nerve fiber layer (RNFL), macular thicknesses and optic nerve head (ONH) parameters...Full Text Available

2009-06-01

159

Determination of antibody response to influenza virus surface glycoproteins by kinetic enzyme-linked immunosorbent assay.  

UK PubMed Central (United Kingdom)

We modified an existing enzyme-linked immunosorbent assay (ELISA) to be able to use new spectrophotometers which can measure the rate of color development in microtiter wells. This new kinetic-based...Full Text Available

1988-10-01

160

Determination of Thermal Properties and Morphology of Eucalyptus Wood Residue Filled High Density Polyethylene Composites  

UK PubMed Central (United Kingdom)

Thermal behaviors of eucalyptus wood residue (EWR) filled recycled high density polyethylene (HDPE) composites have been measured applying the thermogravimetric analysis (TGA) and differential scanning...Full Text Available

161

Atmospheric corrosion in Gran Canaria specifically meteorological and pollution conditions.  

Science.gov (United States)

Carbon steel, copper, zinc and aluminium samples were exposed in different sizes with known ambient parameters in Gran Canaria Island and atmospheric corrosion was investigated. Weight-loss measurements used to determine corrosion damage were complemented...

1998-01-01

162

Plasma flow measurement using directional Langmuir probe under weakly ion-magnetized conditions  

Energy Technology Data Exchange (ETDEWEB)

It is both experimentally and theoretically demonstrated that ion flow velocity at an arbitrary angle with respect to the magnetic field can be measured with a directional Langmuir probe. Based on the symmetry argument, we show that the effect of magnetic field on directional probe current is exactly canceled in determining the ion flow velocity, and obtain the generalized relation between flow velocity and directional probe currents valid for any flowing direction. The absolute value of the flow velocity is determined by an in situ calibration method of the probe. The applicability limit of the present method to a strongly ion-magnetized plasma is experimentally examined. (author)

2000-07-01

163

In-beam spectroscopy of nuclei  

International Nuclear Information System (INIS)

The main features and advantages of a new low energy nuclear spectroscopic method, the in-beam spectroscopy are described. Results of in-beam spectroscopic experiments performed at the Institute of Nuclear Research (ATOMKI, Debrecen, Hungary) are summarized. Gamma spectra of in-beam produced odd-odd nuclei were measured, gamma-energies were determined. Measurement of gamma-gamma coincidences led to the construction of energy level schemes of the investigated nuclei. Internal conversion electron spectroscopy was used to determine the multipolarities of transitions. A few spectra and level schemes are presented to illustrate the review. Theoretical interpretation of experimental results are briefly summarized. (D.Gy.).

1982-01-01

164

Effect of substrate on the results of measuring coating thickness according to radiation scattered by substrate  

International Nuclear Information System (INIS)

The effect of a substrate on the results of measuring tantalum coating thickness in two-layer compositions according to gamma radiation scattered by the substrate is studied. It is shown that by means of an albedo-radiometer realizing the physical model absorber-scatterer one can determine the thickness (application uniformity) of tantalum coatings up to 150-300 #mu#m depending on the substrate material (plexiglas, aluminium, iron, copper). In case of testing coatings on substrates of alloys and high-alloy steels in order to ensure high accuracy of measrurement it is expedient with the above albedo-radiometer to determine the value of the backscattered radiation flux for the substrate before coating application.

165

Determining top dead center in fired internal combustion engines by microwaves  

Energy Technology Data Exchange (ETDEWEB)

For the determination of top dead center (TDC) of a running engine a measuring system using microwaves was developed by AEG and Volkswagen AG. The measuring method utilizes the Doppler shift of the microwaves, which were reflected at the up and down moving piston, and the varying resonance properties of the combustion chamber. The system works with a frequency of 61.4 GHz and can be used as well for spark ignition as form compression ignition engines, particularly for direct injection engines. The output signal is symmetrical to TDC. For data acquisition and data processing, i.e. the calculation of the point of symmetry, the computer system FARES is used in a special assembly.

1986-01-01

166

Determination of uranium and thorium concentrations in integrated circuit packaging materials  

International Nuclear Information System (INIS)

The purpose of the present research is to find a suitable technique to measure trace amounts of uranium and thorium and to determine the surface #alpha#-flux in silicon compound (SiO) used for fabrication of integrated circuit packaging materials. Among several commonly-used detecting techniques, it was found that neutron activation analysis (NAA) was most promising. The results from NAA show a large difference in uranium and thorium concentrations when cadmium and boron carbide shields are used, whereas #alpha#-flux measurements show a low #alpha#-activity, which corresponds to the trace amounts of uranium and thorium expected to be present in these materials. (author) 13 refs.; 6 figs.

167

Radiogauging to investigate two phase flow. Graduation report  

Energy Technology Data Exchange (ETDEWEB)

New measuring methods are developed and are tested with the small reactor simulator MIDAS (Mini Dodewaard ASsembly). The purpose of this work is to be able to measure accurately as many different properties of the flow as possible in the coming bigger simulator SIDAS (Simulated Dodewaard ASsembly). In SIDAS the flow around a fuel assembly of the Dutch Dodewaard reactor will be simulated. An extensive evaluation of the gamma detection system showed that the detection system could be simplified strongly. The simplified system is used to measure the radial and axial distribution of the void fraction in the core of MIDAS for three different operating conditions. Two new measuring methods have been developed and tested. A method to estimate the probability density of the void fraction in time. Due to the nonlinear relation between transmission and void fraction the determined average ...

1992-11-12

168

Reference neutron transport calculation note for Korea nuclear power plants with 3-loop PWR reactors  

Energy Technology Data Exchange (ETDEWEB)

Reactor pressure vessel (RPV) steels are subjected to neutron irradiation at a temperature of about 290 deg C. This radiation exposure alters the mechanical properties, leading to a shift of the brittle-to-ductile transition temperature toward higher temperatures and to a diminution of the rupture energy as determined by Charpy V-notch tests. This radiation embrittlement is one of the important aging factors of nuclear power plants. U.S. NRC recommended the basic requirements for the determination of the pressure vessel fluence by regulatory guide DG-1025 in order to reduce the uncertainty in the determination of neutron fluence calculation and measurements. The determination of the pressure vessel fluence is based on both calculations and measurements. The fluence prediction is made with a calculation and the measurements are used to ...

1997-05-01

169

Radionuclide X-ray fluorescence analysis of solid aerosol particles on Synpor 4 collection filters  

International Nuclear Information System (INIS)

The feasibility was studied of the application of radionuclide X-ray fluorescence analysis to the identification and determination of chemical elements in the air. A description of the method is presented, the main stages of the analysis are discussed (sample preparation and standards, selection of radioactive radiation sources, geometry of measurement and evaluation of results). The method is illustrated on the determination of elements Fe, Cu, Zn, Br, and Pb in air samples taken in the city of Prague. (author) 2 tabs., 2 figs., 14 refs.

1992-01-01

170

Patient doses from medical uses of x-rays  

International Nuclear Information System (INIS)

A survey to determine the annual genetically significant dose and mean bone-marrow dose to the Australian population from radiological procedures has been undertaken. For diagnostic radiology the following were carried out: determination of the frequency of a procedure; measurement of patient doses using TLD and processing of data and calculation of gonadal and bone-marrow doses.

1981-01-01

171

Nondestructive determination of airborne lead particulates by the radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).

1980-01-01

172

Microwave Oven for the Rapid Determination of Total Solids Content of Natural Rubber Latex  

British Library Electronic Table of Contents (United Kingdom)

The suitability of using the microwave oven for the rapid determination of total solids content (TSC) of natural rubber latex has been established over a broad range of dry rubber content (DRC). The total solids content values obtained by the microwave oven method are compared with the values obtained by heating in a conventional convection oven. Heating in a microwave oven is advantageous as the measurement time could be reduced considerably.

2008-01-01

173

Measurement of the half-life of "1"0"1Mo  

International Nuclear Information System (INIS)

"1"0"1Mo is an important radionuclide to determine the burn-up of nuclear fuels, but its half-life reference values had marked differences. It is described in detail the principles and processes of the position normalization method by two high purity germanium detectors to determinate the half-life of "1"0"1Mo. (authors)

2006-11-01

174

Heavy element contamination of surface waters in the region Banska Stiavnica (SR) measured by radionuclide X/ray fluorescence analysis  

International Nuclear Information System (INIS)

Heavy metals (Pb, Cd, Mn, Cu, Zn, Fe) were determined in surface waters in the surroundings of the depositories of the mining shrubs in the region of Banska Stiavnica (SR) by radionuclide X-ray fluorescence analysis. Allowed concentrations of the determined metals are exceeded numerously (multiplicity in some cases was 10"3-10"6). (author).

1997-01-01

175

Heat capacities and densities of electrolyte mixtures in aqueous solution - application to the determination of apparent molar heat capacities and volumes for potassium triiodide and dioxoneptunium(V) perchlorate  

Energy Technology Data Exchange (ETDEWEB)

Apparent molar heat capacities for KI[sub 3](aq) were determined from flow-microcalorimetric measurements of KI(aq) solutions containing dissolved iodine. From these, the conventional partial molar heat capacity C[sub p,2][sup [infinity

1993-05-01

176

Refractometry of organosilica microspheres  

CERN Document Server

The refractive index of novel organosilica (nano/micro)material is determined using two methods. The first method is based on analysis of optical extinction efficiency of organosilica beads versus wavelength, which is obtained by a standard laboratory spectrometer. The second method relies on the measurable trapping potential of these beads in the focused light beam (laser tweezers). Polystyrene beads were used to test these methods, and the determined dispersion curves of refractive index values have been found accurate. The refractive index of organosilica beads has been determined to range from 1.60-1.51 over the wavelength range of 300-1100 nm.

2007-01-01

177

Reactivity from power spectral density measurements with /sup 252/Cf. [LMFBR  

Science.gov (United States)

The theory of a method of determination of the reactivity from power spectral density measurements with /sup 252/Cf and the results of experiments with a critical assembly mock-up of a liquid-metal fast breeder reactor and with uranium (93.2 wt % /sup 235/U) metal cylinders and a sphere are presented. This method of reactivity determination has an advantage over existing methods in that it determines the reactivity only from properties of the reactor at the subcritical state of interest and thus does not require a calibration near delayed criticality. In these experiments the reactivity was varied by changing the fissile loading or the amount of neutron absorber inserted; for the LMFBR mock-up, the reactivity varied to approximately 75 dollars subcritical, and for the uranium metal assemblies, to approximately 30 dollars subcritical.

1977-08-01

178

Determining the porosity of rock in oil wells using compensated neutron logging  

Energy Technology Data Exchange (ETDEWEB)

The two-sonde neutron-logging device RKS-2 registers the ratios of the indications of two sondes and is scaled in units representing the total water content of pure limestone when saturated with fresh water. When analyzing the results of the measurements in real wells, it is necessary to calculate the effect of well- and strata conditions on the results of porosity determination. The results of simulated measurements are presented, on the basis of which correction factors are immediately determined for the calculation of the effect of the diameter of the well, and the effect of the mud cake on the well wall. A nomogram is constructed and substantiated; its purpose is the calculation of the effect of the following on the RKS-2 indication: the diameter of the well, the mud cake on the well wall, the density of the drilling solution, temperature, pressure in the well, and the lithology of the rock.

1982-01-01

179

Determination of radon and thoron permeability through some plastics by track technique  

Energy Technology Data Exchange (ETDEWEB)

Experiments have been performed to study the usefulness of several types of plastic foils as filter to separate radon and thoron. Time-integrated alpha-activity measurements have been carried out by using the so-called ''can-technique'' equipped with both LR-115 and CR-39 track detectors. The track density observed on the detectors, taken as a measure of radon activity concentration, has been determined as a function of the thickness of filter foils. The radon permeability and the thoron separation factors have been determined. It is shown that various plastic foils exhibit considerable differences in radon diffusion coefficient owing to their different chemical structures. Among the plastic foils investigated the polyethylene proved to have the highest gas diffusion coefficient.

1986-01-01

180

Surface probe measurements in ISX-B and EBT-S  

Energy Technology Data Exchange (ETDEWEB)

Surface deposition probe techniques have been shown to be an effective means of determining the characteristics of the plasma edge region of magnetic confinement devices. Experimental results on ISX-B and EBT-S have led to a consistent picture of the edge plasma and the dominant impurity introduction mechanisms. This picture is supported by numerous other measurements and emphasizes the importance of concentrating several techniques on the complex problems of plasma fusion.

1982-12-01

181

Standard deviation of measurement results in x-ray fluorescence spectrometry  

International Nuclear Information System (INIS)

The standard deviation of measurement results of a given element in XRF spectrometry depends on three factors: concentration and concentration region, atomic number and matrix. The effects of these factors were investigated by an XRF instrument type ARL 72.000 for aluminium metal, bauxite-red mud and aluminium using computerized data processing. A comparison of linear and nonlinear relation between concentration and the result of XRF analysis was made for the determination of standard deviation. (R.P.).

1984-11-13

182

Reconnaissance technique for radon risk classification of foundation soils  

Energy Technology Data Exchange (ETDEWEB)

Infiltration of radon from the ground is usually the primary source of indoor radon pollution. A uniform method for radon risk classification of foundation soils based on soil-gas radon concentration measurements and on the determination of soil porosity, permeability and structure was proposed in 1990. Results of assessment of some areas in Czechoslovakia, containing more than 5000 radon concentration measurements, demonstrate the utility of the technique and confirm the link between geology and radon potential of the soil. (author)

1992-07-01

183

Quantifying octahedral rotations in strained perovskite oxide films.  

Energy Technology Data Exchange (ETDEWEB)

We have measured the oxygen positions in LaNiO{sub 3} films to elucidate the coupling between epitaxial strain and oxygen octahedral rotations. The oxygen positions are determined by comparing the measured and calculated intensities of half-order Bragg peaks, arising from the octahedral rotations. Combining ab initio density-functional calculations with these experimental results, we show how strain systematically modifies both bond angles and lengths in this functional perovskite oxide.

2010-07-20

184

Measurement of radiative, Auger, and nonradiative currents in 1. 3-. mu. m InGaAsP buried heterostructure lasers  

Energy Technology Data Exchange (ETDEWEB)

Frequency response measurements are used to determine the carrier lifetime of 1.3-..mu..m InGaAsP buried heterostructure lasers between 1 mA and threshold. The data confirm previous results on the radiative and Auger recombination coefficients and reveal the presence of a nonradiative current which dominates at low currents and contributes 4 mA at threshold.

1987-02-09

185

Measurement of gas flow velocities by laser-induced gratings  

Energy Technology Data Exchange (ETDEWEB)

Time resolved light scattering from laser-induced electrostrictive gratings was used for the determination of flow velocities in air at room temperature. By measuring the velocity profile across the width of a slit nozzle we demonstrated the high spatial resolution (about 200 mm) of this novel technique. (author) 3 figs., 1 ref.

1999-08-01

186

Determination of the conversion factor for infrared measurements of carbon in silicon  

Energy Technology Data Exchange (ETDEWEB)

The carbon content of silicon single crystals and polycrystals has been measured by charged particle activation analysis (CPAA) and infrared absorption. The authors obtained a linear relationship between the absorption coefficient at 605 cm/sup -1/ and the carbon content obtained by CPAA. They obtained a conversion factor of (1.00 +- 0.03) 10/sup 17//cm/sup 2/ for a 100% substitutional carbon.

1986-10-01

187

Corrections for non-homogeneity of the sample in Moessbauer f-factor measurements  

Energy Technology Data Exchange (ETDEWEB)

We describe a procedure for correcting the systematic errors in the Moessbauer f-factor measurement due to non-homogeneous effective thickness of the sample. To be more precise, we show that, if the mass of the sample is determined by means of X- or {gamma}-ray absorption, it is possible to establish experimental conditions so that the error on f due to material non-homogeneity in the sample is minimized.

2002-06-01

188

Calculated fluence spectra at neutron therapy facilities  

International Nuclear Information System (INIS)

The Monte Carlo transport codes LAHET and MCNP were used to calculate energy fluence spectra at three neutron therapy facilities. The results compare very favourably with measured data. Kerma spectra and the ratio of ICRU muscle tissue kerma to A-150 kerma, along the carbon to oxygen kerma ratio, were determined. Absorbed dose rate calculations are in reasonable agreement with measured values. Use of these codes to study modifications to existing therapy beams is briefly discussed. (author).

1995-11-13

189

Vacuum ultraviolet radiometry of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two ...

1995-10-01

190

Impedance Noise Identification for State-of-Health Prognostics  

Energy Technology Data Exchange (ETDEWEB)

Impedance Noise Identification is an in-situ method of measuring battery impedance as a function of frequency using a random small signal noise excitation source. Through a series of auto- and cross-correlations and Fast Fourier Transforms, the battery complex impedance as a function of frequency can be determined. The results are similar to those measured under a lab-scale electrochemical impedance spectroscopy measurement. The lab-scale measurements have been shown to correlate well with resistance and power data that are typically used to ascertain the remaining life of a battery. To this end, the Impedance Noise Identification system is designed to acquire the same type of data as an on-board tool. A prototype system is now under development, and results are being compared to standardized measurement techniques such as electrochemical impedance spectroscopy. ...

2008-07-01

191

Automated bead-positioning system for measuring impedances of R-F cavity modes  

Energy Technology Data Exchange (ETDEWEB)

We describe a fully automated bead puller system which uses stepping motors to position the bead, and an HP-8510 network analyzer to measure the resulting frequency shifts, both devices being under computer control. Longitudinal motion of the bead is used for measurement of cavity shunt impedance. In addition, azimuthal scans at fixed longitudinal position aid in determining the multipole character of higher-order modes. High sensitivity/accuracy is made possible by measuring phase shifts at the unperturbed resonant frequencies (rather than frequency shifts themselves), thereby permitting averaging factors of > 500 with only modest increases in data acquisition time. Sample measurements will be presented. A comprehensive analysis of the experimental results is presented in an accompanying paper.

1993-05-01

192

The determination of optical conditions of Fuji computed radiography (FCR) in pelvimetry and the reduction of radiation dose to mother and fetus  

Energy Technology Data Exchange (ETDEWEB)

The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).

1991-05-01

193

The determination of optical conditions of Fuji computed radiography (FCR) in pelvimetry and the reduction of radiation dose to mother and fetus  

International Nuclear Information System (INIS)

The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).

1991-01-01

194

Quantitative measurement of elements in a composite, using multienergy gamma-rays  

International Nuclear Information System (INIS)

This study is an attempt to measure the quantities of elements in a composite by irradiating that composite with #gamma#-rays of various energies and detecting the transmitted radiation through the composite. A previous knowledge of the number of the elements and their attenuation coefficients is required. The quantities are calculated by solving the matrix of a linear system of equations. A computer program was developed to select the best combinations of the available energies. Five criteria were established to determine these energy combinations: (i) the determinant of the attenuation coefficient matrix; (ii) the condition number, (iii) the number of times the solution of the matrix leads to acceptable results; (iv) the indicator, (a new concept); (v) the standard deviations of the results. The intended application of this technique in medicine is to measure the bone mineral content of the skeleton. ...

195

Influence of pollution abatement measures on the evaluation of air pollution caused by heating systems with special regard to the costs involved. Einfluss von emissionsmindernden Massnahmen auf die Schadstoffbewertung der Heizsysteme unter Beruecksichtigung der damit verbundenen Kosten  

Energy Technology Data Exchange (ETDEWEB)

Apart from presenting the marginal legal conditions the research program contains a brief description of current pollution abatement measures, representative heating systems and individually suitable pollution abatement technologies and an account of the determination of the concentration of major pollutants. The comparative evaluation of heating systems assesses their environmental effects, i.e. air pollution caused by heating systems. The determination of the costs of available heat is followed by an overall evaluation of the results obtained with special regard to the costs involved by pollution abatement measures.

1986-01-01

196

Absolute subcriticality measurement without calibration and detection efficiency dependence by the /sup 252/Cf source-driven noise method  

Energy Technology Data Exchange (ETDEWEB)

The /sup 252/Cf-source-driven noise analysis method determines the subcriticality of a system containing fissionable material from the ratio of cross power spectral densities between the detectors that detect particles from the fission process and between these detectors and an ionization chamber containing a spontaneously fissioning neutron source which provides neutrons to induce fission in the system. This method has two advantages: (1) a calibration is not required and thus subcriticality can be determined from measurements only on the subcritical system of interest, and (2) the subcriticality is independent of the type of detector or its efficiency. These properties of this technique are illustrated by measurements.

1984-01-01

197

Single parameter analysis of hysteretic magnetic flux trapping in high T{sub c} superconductor ribbon  

Energy Technology Data Exchange (ETDEWEB)

This paper described the application of an AC surface probe, similar to presently used eddy current probes, to the measurement of DC transport critical currents and critical state dissipation in high {Tc} superconductors. It has been shown that the probe can provide quantitative measurement of the full field penetration in superconducting samples by measuring the response of AC induced screening currents for superconducting materials in the form of tapes with overlayers of silver. In this manner, the AC probe can be used to replace the contact DC probe for determining critical currents in a noncontacting and local manner suitable for scanning over or along the sample.

1992-10-01

198

Single parameter analysis of hysteretic magnetic flux trapping in high T_c superconductor ribbon  

International Nuclear Information System (INIS)

This paper described the application of an AC surface probe, similar to presently used eddy current probes, to the measurement of DC transport critical currents and critical state dissipation in high T_c superconductors. It has been shown that the probe can provide quantitative measurement of the full field penetration in superconducting samples by measuring the response of AC induced screening currents for superconducting materials in the form of tapes with overlayers of silver. In this manner, the AC probe can be used to replace the contact DC probe for determining critical currents in a noncontacting and local manner suitable for scanning over or along the sample.

1992-07-19

199

Single parameter analysis of hysteretic magnetic flux trapping in high T[sub c] superconductor ribbon  

Energy Technology Data Exchange (ETDEWEB)

This paper described the application of an AC surface probe, similar to presently used eddy current probes, to the measurement of DC transport critical currents and critical state dissipation in high [Tc] superconductors. It has been shown that the probe can provide quantitative measurement of the full field penetration in superconducting samples by measuring the response of AC induced screening currents for superconducting materials in the form of tapes with overlayers of silver. In this manner, the AC probe can be used to replace the contact DC probe for determining critical currents in a noncontacting and local manner suitable for scanning over or along the sample.

1992-01-01

200

Simulation of the transient eddy current measurement for the characterization of depth and conductivity of a plate  

International Nuclear Information System (INIS)

A transient eddy current measurement method is presented to determine the thickness and conductivity of a conductive plate. The conductive plate is induced by an air-cored coil, the magnetic flux density along the axial is measured and the various signals corresponding to plates with different thickness and conductivity are calculated using a 3D transient eddy current simulator. Characteristic features are obtained from the transient response. A similarity-based modeling method is utilized in this study to estimate the thickness and conductivity of the conductive plate. (author)

2008-07-01

201

Radon startup analysis at a Roosevelt Hot Springs, Utah geothermal well  

Energy Technology Data Exchange (ETDEWEB)

The evaluation of radon concentration measurements in newly developing geothermal reservoirs with the objective of determining the ability of measured changes in noncondensible gas components, such as radon, to predict changes in the thermodynamic properties of the reservoir is described. This ability would be especially useful in liquid-dominated resources, where changes in steam fraction are sensitive to changes in reservoir temperature and fluid enthalpy. Radon measurements were made in samples separated by phase at the outlets of a prototype rotary separator turbine. The data were examined in relation to the thermodynamic properties of the geofluids supplied by the test well.

1983-09-01

202

Quantitative density measurements from a real-time neutron radiography system  

Energy Technology Data Exchange (ETDEWEB)

An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.

1986-01-01

203

Quantitative density measurements from a real-time neutron radiography system  

International Nuclear Information System (INIS)

An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.

1986-11-16

204

Measurements for microamounts of SO_4"2"-, Br"-, I"- ions in the carnallite  

International Nuclear Information System (INIS)

The variations of measurements were estimated for microamounts SO_4"2"-, Br"-, I"- ions in samples of carnallite by ionchromatography method. The composition of carbonate eluent was verified. The investigated minima were about 0,004 %, 0,001 %, 0,01 % for SO_4"2"-, Br"-, I"- completively correspondingly. It was shown that the limit of ion-chromatography measurement would be decreased when Br"- and I"- ions were concentrated by extraction before. Besides the determination of I"- ion in carnallite was preformed by potentiometry with I"--ionselective electrode. 6 refs.; 3 tabs.

1995-01-01

205

Electron momentum density measurements by means of positron annihilation and Compton spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

The electron momentum density is measured applying positron annihilation and Compton spectroscopy in order to get information about electron wave functions. Compton spectroscopic measurements of Pd-Ag and Cu-Zn alloy systems are carried out taking into account crystal structure, mixability, and order state. Three-dimensional momentum densities of silicon are determined in order to get better information about its electronic structure. The momentum density and the spin density of ferromagnetic nickel are investigated using angular correlation curves.

1982-01-01

206

Determination of vapor pressures, enthalpies of sublimation, and enthalpies of fusion of benzenetriols  

Energy Technology Data Exchange (ETDEWEB)

Molar enthalpies of sublimation of 1,2,4-, 1,2,3-, and 1,3,5-tri-hydroxy-benzene, were obtained from the temperature dependence of the vapor pressure measured by the transpiration method. The molar enthalpies of fusion and molar heat capacities of these compounds were measured by DSC. The measured data sets of vaporization, sublimation and fusion enthalpies were checked for internal consistency. Strength of the inter- and intra-molecular hydrogen bonding in di- and tri-hydroxy-benzenes have been assessed.

2004-06-07

207

Damping measurements of the magnesium wrought alloys AZ31, AZ61 and AZ80 after indirect and hydrostatic extrusion  

Energy Technology Data Exchange (ETDEWEB)

Magnesium cast parts as well as indirectly and hydrostatically extruded profiles were used in order to investigate the influence of different microstructures on the damping behaviour of magnesium AZ-alloys. Especially, hydrostatic extrusion leads to a significant grain refinement in the extruded profile compared to indirect extrusion. Strain dependent damping measurements were carried out at room temperature using alloys AZ31, AZ61 and AZ80. Damping was determined as the logarithmic decrement of free bending beam vibrations. The results of these measurements after indirect and hydrostatic extrusion are shown and discussed. (orig.)

2005-07-01

208

Absolute calibration of the antiproton detection efficiency for BESS below 1 GeV  

Energy Technology Data Exchange (ETDEWEB)

An accelerator beam experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of the BESS detector. Measured and calculated efficiencies derived from the BESS Monte Carlo simulation based on GRANT/GHEISHA showed good agreement. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be {+-}5%, compared with the previous estimation of {+-}15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux. (author)

2001-12-01

209

Radioanalytical determination of chromium in welding fumes  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis and fast neutron activation analysis were used for the determination of chromium. The excitation source for X-ray fluorescence analysis was a ring-shaped "2"4"1Am source with an activity of 18.5x10"9 Bq. SYNPOR filters of 35 mm in diameter were used for the measurement. The 5.414 keV Cr peak was measured with a Si(Li) detector. The sensitivity was 0.05 mg for a period of measurement of 1000 s. A neutron generator with an emission of 10"9 s"-"1 was used as the source of fast neutrons. "5"2V and "5"3V, the products of nuclear reaction with Cr, were measured gamma spectrometrically with a Ge(Li) detector. The sensitivity for Cr is 0.015 mg, in the presence of Mn which causes interference the sensitivity is a mere 0.075 mg. The mentioned methods were used to determine total Cr and Cr(VI) in welding aerosols. It was found that ...

1985-01-01

210

Measuring instrument for radiometric monitoring of solids and heavy metals in water  

International Nuclear Information System (INIS)

A combination of measuring instruments, consisting of a Beta-Sedimeter and a radionuclide X-ray fluorescence instrument, is described. With the Beta-Sedimeter the C-14-radiation is measured. Through direct irradiation with photons of a Pu238-source in an ancillary irradiation chamber and energy dispersing measurement of the K- and L-radiation resp. of the excited heavy metals with the aid of a Si(Li)-semiconductor detector and a 4-channel analyzer the heavy metal concentrations of the heavy metals Zn, Cr, Ni and Pb are determined. For the determination of cadmium the indirect excitation with Am-241 and Dy-targets is described. The system produces records and operates fully automatically in a step-by-step mode with a testing cycle of 45 minutes. In connection with the process monitoring of the wastewater from a zinc plating plant during a period of 8 months the concentration of the ...

1979-01-01

211

Measurement of the Electron Affinities of Indium and Thallium  

Energy Technology Data Exchange (ETDEWEB)

The electron affinities of indium and thallium were measured in separate experiments using the laser-photodetachment electron spectroscopy technique. The measurements were performed at the University of Nevada, Reno. Negative ion beams of both indium and thallium were extracted from a cesium-sputter negative ion source, and mass analyzed using a 90{sup o} bending magnet. The negative ion beam of interest was then crossed at 90{sup o} with a photon beam from a cw 25-Watt Ar{sup +} laser. The resulting photoelectrons were energy analyzed with a 160{sup o} spherical-sector spectrometer. The electron affinity of In({sup 2}P{sub 1/2}) was determined to be 0.404 {+-} 0.009 eV and the electron affinity of thallium was determined to be 0.377 {+-} 0.013 eV. The fine-structure splittings in the ground states of the negative ions were also determined. The experimental ...

1999-03-20

212

Burnup determination of spent nuclear fuel in the pool  

Energy Technology Data Exchange (ETDEWEB)

A algorithm was developed to determine the characteristic parameters of PWR spent fuel, such as burnup, cooling time and initial enrichment of {sup 235}U by use of gamma-ray activity ratios of {sup 134}Cs/{sup 137}Cs, {sup 154}Eu/{sup 137}Cs and {sup 106}Ru/{sup 137}Cs from the high resolution gamma-ray spectroscopy and ORIGEN-S calculations. For the verification of the method developed, gamma-ray measurements of Kori-1 and Kori-2 nuclear fuel rods were carried out using HPGe gamma ray scanning system. As a results, it is revealed that the measured values are in a good agreement with the operator declared values within the about {+-} 5% errors. Besides, the under-water burnup measuring device has been designed to measure the gamma-ray from the PWR spent fuel assembly. This device will be set up in the pool of Post-Irradiation Examination Facility(PIEF), and used in ...

1998-06-01

213

Application od scaling technique for estimation of radionuclide inventory in radioactive waste  

International Nuclear Information System (INIS)

Safety studies related to the disposal of low- and intermediate waste indicate that the long term risk is determined by the presence of long-lived nuclides such as "1"4C, "5"9Ni, "6"3Ni, "9"9Tc, "1"2"9I and the transuranium elements. As most of these nuclides are difficult to measure, the correlation between these critical nuclides and some other easily measurable key nuclides such as "6"0Co and "1"3"7Cs has been investigated for typical waste streams of Paks Nuclear Power Plant (Hungary) and scaling factors have been proposed. An automated gamma-scanning monitor has been purchased and calibrated to determine the gamma-emitting radionuclides. Radiochemical methods have been developed to determine significant difficult-to-measure radionuclides. The radionuclides of interest have been "3H, "1"4C, "9"0Sr, "5"5Fe, "5"9Ni, "9"9Tc, "1"2"9I and TRUs. The ...

1996-09-16

214

Origin determination of plutonium material in nuclear forensics  

International Nuclear Information System (INIS)

Plutonium, seized from illicit trafficking in nuclear materials, can originate from several, distinct sources. The primary focus of nuclear-forensics investigations of confiscated Pu is to specify correctly its origin. Such specification is possible by means of accurate determination the Pu isotopic composition. Five Pu samples of different origins were analysed by thermal-ionisation mass spectrometry. The source (i.e., the type of production reactor) of each sample was determined by comparing the measured Pu isotopic composition with that calculated by one of two reactor-production computer codes, ORIGEN2 and SCALE. These results, in conjunction with the age determination of each sample, allow us to deduce the origin of each. (author)

2000-11-01

215

Determination of the biodegradation rate of asphalt for the Hanford grout vaults. Hanford Grout Technology Program  

Energy Technology Data Exchange (ETDEWEB)

Testing was initiated in March 1991 and completed in November 1992 to determine the rate at which asphalt is biodegraded by microorganisms native to the Hanford Site soils. The asphalt tested (AR-6000, US Oil, Tacoma, Washington) is to be used in the construction of a diffusion barrier for the Hanford grout vaults. Experiments to determine asphalt biodegradation rates were conducted using three separate test sets. These test sets were initiated in March 1991, January 1992, and June 1992 and ran for periods of 6 months, 11 months, and 6 months, respectively. The experimental method used was one originally developed by Bartha and Pramer (1965), and further refined by Bowerman et al. (1985), that determined the asphalt biodegradation rate through the measurement of carbon dioxide evolved.

1993-04-01

216

Determination of selected elements by radionuclide X-ray fluorescence analysis after the separation on different kinds of sorption materials  

International Nuclear Information System (INIS)

This paper aimed to the evaluation of different kinds of sorbent material preparation and to the evaluation of their characteristics at different pH conditions by X-ray fluorescence analysis. This method is suitable for identification and determination of elements in samples of different character, state and origin because it is a polycomponent, non-destructive, fast and simple analytical method. Moreover, it allows timeadvantageous and reliable measurements. This paper studies problems concerning the determination of some selected elements (Mn, Fe, Ni, Cu, Zn, Pb) in pharmaceutical samples of sodium chloride in the solid state as well as in its solution by sorption on chelating extraction membrane 3M Empore"T"M and on the strongly acidic ion-exchanger Dowex 50Wx8. Conditions for the most effective sorption of determined elements are also interpreted. (author)

2008-03-01

217

Effect of paraquat on microsomal lipid peroxidation in vitro and in vivo. [Rats, rabbits, man, mice  

Energy Technology Data Exchange (ETDEWEB)

Rat lung and liver microsomes did not undergo lipid peroxidation in the absence of iron when incubated with NADPH and concentrations of paraquat ranging from 10/sup -7/ to 10/sup -2/ M. Paraquat also did not stimulate rat liver and lung microsomal peroxidation induced by added iron and NADPH, and was inhibitory at concentrations above 10 ..mu..M. Similarly, no stimulation of peroxidation was produced by paraquat in rabbit or human lung microsomes; however, under similar conditions, paraquat enhanced NADPH/iron-dependent peroxidation in mouse lung and liver microsomes obtained from rats sacrificed at 12, 18, and 24 hr following a lethal dose of paraquat (50 mg/kg, ip), there was no loss of vitamin E or increase in susceptibility to in vitro peroxidation which would be expected if lipid peroxidation had occurred in vivo although extensive lung damage developed during this time period. These results indicate that paraquat does not cause pulmonary toxicity by ...

1980-01-01

218

Animal and human studies of a new /sup 99m/Tc labelled phosphine-isocyanide complex with possible applications to radionuclide ventriculography  

Energy Technology Data Exchange (ETDEWEB)

A new /sup 99m/Tc-phosphine-isocyanide complex with the general structure (/sup 99m/Tc (DEPE)/sub 2/(CNR)/sub 2/)/sup +/ has been synthesised and tested in animals and one human. In three animal species (rat, rabbit, dog), the complex is an efficient myocardial imaging agent, while in humans it remains in the blood pool. The complex is 100% protein bound in animals and humans, but whereas in humans it is attached to a 51.5 kdalton protein (probably prealbumin), in rabbits it appears to be bound to a larger macromolecule (M.W.>100 kdalton). The efficiency of the complex for blood pool labelling was tested in a human volunteer and compared with the standard in vivo red cell labelling technique with stannous pyrophosphate. A satisfactory radionuclide angiogram could be performed with less than 370 MBq of the complex. The count rate for the complex (cps/MBq) was 15% higher than that obtained with the labelled red cells and the absence of splenic ...

1987-04-01

219

Measuring properties of impulsive low frequency noise by different measuring set up. Shogekisei teishuhaon no keisokuki ni tsuite no kento  

Energy Technology Data Exchange (ETDEWEB)

Pollution abatement measures against impulsive low frequency noises including mine blasting noise require precise measurement of sound waveforms, but no instruments have been designed for that purpose, nor commercially available. This paper describes investigations on such instruments as noise level meters currently available commercially on their instrumental characteristics using indoor experiments and field measurements. The following matters were clarified: An instrument combining a microphone with an amplifier can not determine the response from the measuring system from the respective frequency characteristics alone, and requires a discussion on the overall response from the measuring system. A preferred noise level meter would be an instrument that has the lower limit for the frequency characteristics of the microphone extended to several hertz, and ...

1991-11-25

220

Crosscheck of different techniques for two dimensional power spectral density measurements of x-ray optics  

Energy Technology Data Exchange (ETDEWEB)

The consistency of different instruments and methods for measuring two-dimensional (2D) power spectral density (PSD) distributions are investigated. The instruments are an interferometric microscope, an atomic force microscope (AFM) and the X-ray Reflectivity and Scattering experimental facility, all available at Lawrence Berkeley National Laboratory. The measurements were performed with a gold-coated mirror with a highly polished stainless steel substrate. It was shown that these three techniques provide essentially consistent results. For the stainless steel mirror, an envelope over all measured PSD distributions can be described with an inverse power-law PSD function. It is also shown that the measurements can be corrected for the specific spatial frequency dependent systematic errors of the instruments. The AFM and the X-ray scattering measurements were used to ...

2005-07-12

221

Cross-check of different techniques for two-dimensional powerspectral density measurements of X-ray optics  

Energy Technology Data Exchange (ETDEWEB)

The consistency of different instruments and methods for measuring two-dimensional (2D) power spectral density (PSD) distributions are investigated. The instruments are an interferometric microscope, an atomic force microscope (AFM) and the X-ray Reflectivity and Scattering experimental facility, all available at Lawrence Berkeley National Laboratory. The measurements were performed with a gold-coated mirror with a highly polished stainless steel substrate. It was shown that these three techniques provide essentially consistent results. For the stainless steel mirror, an envelope over all measured PSD distributions can be described with an inverse power-law PSD function. It is also shown that the measurements can be corrected for the specific spatial frequency dependent systematic errors of the instruments. The AFM and the X-ray scattering measurements were used to ...

2005-04-17

222

Placental transfer of 14C-hexoprenaline  

International Nuclear Information System (INIS)

The placental transfer of a single intravenous injection of 14C-hexoprenaline was studied in eight pregnant New Zealand white rabbits. Maternal and fetal blood was sampled intermittently for 60 minutes after the injection. An initial rapid decrease in the levels of 14C-hexoprenaline in maternal blood was followed by a second slower phase, whereas fetal levels remained insignificant. The conclusion, therefore, is that the rapid improvement in fetal heart rate after the administration of a single maternal intravenous injection of hexoprenaline in the treatment of fetal distress is due to the action on the uterus and/or on maternal cardiovascular function, and not to direct stimulation of the fetus.

1982-02-01

223

Use of receptor affinity chromatography in purification of the growth hormone-like factor produced by plerocercoids of the tapeworm Spirometra mansonoides.  

Science.gov (United States)

The plerocercoid stage of the tapeworm Spirometra mansonoides produces a functional analog of human growth hormone (hGH). Among the similarities between plerocercoid growth factor (PGF) and hGH is competition for the same receptors on rabbit liver membranes. To take advantage of this characteristic in a purification scheme for PGF, rabbit liver microsomes were solubilized in Triton X-100 and the hGH receptors were purified over an hGH affinity column. The purified receptors from six rabbit livers were coupled to Affi-Gel-10 to create a receptor affinity column which was used to purify PGF. Chromatography of crude PGF over the receptor column resulted in a 1044 fold increase in specific activity. SDS-PAGE in the presence of 2-mercaptoethanol showed that the affinity-purified PGF contained three protein bands with apparent Mrs of 27.5 K, 22 K, and 16.7 K. Injections of the partially-purified PGF into hypophysectomized rats ...

1988-01-01

224

Study of proton therapy on malignant tumors. Effects in twenty-four hours after proton irradiation  

Energy Technology Data Exchange (ETDEWEB)

We irradiated proton beams on the ears of rabbits and the Harding-Passey mouse melanoma and observed their morphological change. We used 52 MeV proton beams from the INS-FM cyclotron. We adjusted the energy of the proton beams to be at the plateau part of the Bragg curve, at the half-way point of the Bragg peak, and at the Bragg peak. The amount of radiation was 5000rad in each case. The Harding-Passey mouse melanoma was transplanted into the subcutan of a three week old mouse. In this experiment, we used tumors, the diameter of which grew up to 1.5-2cm in 2-3 weeks after the transplantation. Using the jroscope, we observed both lightly and severely damaged cells. Using proton irradiation with the Bragg peak located at depth of 1mm in the rabbit's ears, we studied the change in the tissue. Irradiated epidermis fell off and was eroded because of radiation damage, but the rear surface of the rabbit's ears ...

1983-01-01

225

Transient radon diffusion through radon-proof membranes: A new technique for more precise determination of the radon diffusion coefficient  

Energy Technology Data Exchange (ETDEWEB)

The following paper is focused on the numerical modelling of the transient radon diffusion through radon-proof membranes during the measurement of their radon diffusion coefficient. The major aim of such numerical modelling is to increase the accuracy of radon diffusion coefficients derived from the measured data sets. The developed complex ''transient'' numerical model is able to calculate the radon diffusion coefficient with sufficient accuracy from almost any data set - even from a short-time measurement with a non-linear course of results. This numerical model can also be used for various analyses of transient radon transfer processes (e.g. for the calculation of radon distribution curves within the membrane). The following paper presents governing equations for the simulation model, together with a brief description of algorithms incorporated in the newly developed software package, ...

2009-06-15

226

DETERMINATION OF 237NP AND PU ISOTOPES IN LARGE SOIL SAMPLES BY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY  

Energy Technology Data Exchange (ETDEWEB)

A new method for the determination of {sup 237}Np and Pu isotopes in large soil samples has been developed that provides enhanced uranium removal to facilitate assay by inductively coupled plasma mass spectrometry (ICP-MS). This method allows rapid preconcentration and separation of plutonium and neptunium in large soil samples for the measurement of {sup 237}Np and Pu isotopes by ICP-MS. {sup 238}U can interfere with {sup 239}Pu measurement by ICP-MS as {sup 238}UH{sup +} mass overlap and {sup 237}Np via {sup 238}U peak tailing. The method provides enhanced removal of uranium by separating Pu and Np initially on TEVA Resin, then transferring Pu to DGA resin for additional purification. The decontamination factor for removal of uranium from plutonium for this method is greater than 1 x 10{sup 6}. Alpha spectrometry can also be applied so that the shorter-lived {sup 238}Pu isotope can be measured ...

2010-07-26

227

Bench-scale Kinetics Study of Mercury Reactions in FGD Liquors  

Energy Technology Data Exchange (ETDEWEB)

This document is the final report for Cooperative Agreement DE-FC26-04NT42314, 'Kinetics Study of Mercury Reactions in FGD Liquors'. The project was co-funded by the U.S. DOE National Energy Technology Laboratory and EPRI. The objective of the project has been to determine the mechanisms and kinetics of the aqueous reactions of mercury absorbed by wet flue gas desulfurization (FGD) systems, and develop a kinetics model to predict mercury reactions in wet FGD systems. The model may be used to determine optimum wet FGD design and operating conditions to maximize mercury capture in wet FGD systems. Initially, a series of bench-top, liquid-phase reactor tests were conducted and mercury species concentrations were measured by UV/visible light spectroscopy to determine reactant and byproduct concentrations over time. Other measurement methods, such as atomic absorption, ...

2008-03-31

228

Transient-diffusion measurements of radon. Practical interpretation of measured data  

International Nuclear Information System (INIS)

The mathematical calculation to obtain a radon diffusion coefficient from measured radon transient-diffusion data is usually done by fitting a difference equation to the data. The difference equation is obtained through transformation of the time-dependent diffusion equation based on Fick's law. But, actual measured transient-diffusion data often have much scatter. Therefore just fitting over the whole range of the measured data through the method of least squares may not always be valid, because the method offers mathematical interpretation rather than a physical one. Instead, the actual radon diffusion coefficients must be otherwise obtainable from measured radon transient data. Taking this viewpoint, the present paper claims that about a 90% leveling-off time is often easily discernible regardless of the shape of the radon transient curve obtained from the measured data and it ...

2007-07-01

229

Does adenine incorporation into nucleic acids measure total microbial production:: a response to comments by Fuhrman et al  

Science.gov (United States)

The uptake and incorporation of (/sup 3/H)adenine as a measure of total microbial (bacteria and unicellular algae) nucleic acid synthesis depends on the validity of several assumptions. A unique characteristic of the (/sup 3/H)adenine method is the ability to measure the specific radioactivity (nCi pmol/sup -1/) of the immediate precursor pool of the adenine incorporated into nucleic acids. This measurement permits correction for isotope dilution when the added radiotracer mixes with exogenous pools of structurally related compounds before uptake and with endogenous pools after transport into the cells. The immediate precursors to (/sup 3/H)adenine incorporation into cellular RNA and DNA are ATP and dATP. Since the intracellular dATP pool is in isotopic equilibrium with the ATP pool, one can determine the specific radioactivity of both precursor pools by measuring that of the ...

1986-11-01

230

Thermal radiation from hot surfaces measured by optical and calorimetric methods. Master's thesis  

Energy Technology Data Exchange (ETDEWEB)

The radiative heat loss from a surface is determined by its total hemispherical emittance, which consequently plays an important role in aerospace and solar applications. This study compares emittances measured calorimetrically with values derived from near normal incidence spectral reflectance measurements. This optical derivation is based on a number of assumptions which limit the accuracy if not sufficiency fulfilled. These assumptions include sample specularity, a straybody character beyond the range of measurement, only small variations of emittance with temperature, and a perfectly smooth sample surface. The comparison of calorimetrically and optically derived emittance performed in this study not only quantifies the errors introduced by insufficient fulfillment of the assumptions but also identifies which assumption causes the dominant error. The calorimetric emissometer, constructed for this ...

1982-01-01

231

Research on Actinides in Nuclear Fuel Cycles  

International Nuclear Information System (INIS)

The electrochemical/spectroscopic integrated measurement system was designed and set up for spectro-electrochemical measurements of lanthanide and actinide ions in high temperature molten salt media. A compact electrochemical cell and electrode system was also developed for the minimization of reactants, and consequently minimization of radioactive waste generation. By applying these equipment, oxidation and reduction behavior of lanthanide and actinide ions in molten salt media have been made. Also, thermodynamic parameter values are determined by interpreting the results obtained from electrochemical measurements. Several lanthanide ions exhibited fluorescence properties in molten salt. Also, UV-VIS measurement provided the detailed information regarding the oxidation states of lanthanide and actinide ions in high temperature molten salt media

2007-04-01

232

Radon Levels and Related Doses in a Prototype Jamaican House Constructed with Bauxite Waste Blocks  

Energy Technology Data Exchange (ETDEWEB)

Measurements are presented of indoor radon levels made in a prototype house constructed partly of bauxite waste (red mud) and partly of conventional materials. The mud used contains higher than the average amounts of {sup 226}Ra and {sup 232}Th found in local building materials. The rates of exhalation of radon from the material used in the construction of the house are measured and employed with measured air change rates to make estimates of the average contribution of the various materials to the measured radon levels indoors. There is fairly good agreement between the two. The increment of radon related dose equivalents above background are also estimated and these are combined with previously determined gamma dose equivalents and used as a basis for assessing the acceptability of the practice of using red mud as a building material. (author)

1999-07-01

233

Radon Levels and Related Doses in a Prototype Jamaican House Constructed with Bauxite Waste Blocks  

International Nuclear Information System (INIS)

Measurements are presented of indoor radon levels made in a prototype house constructed partly of bauxite waste (red mud) and partly of conventional materials. The mud used contains higher than the average amounts of "2"2"6Ra and "2"3"2Th found in local building materials. The rates of exhalation of radon from the material used in the construction of the house are measured and employed with measured air change rates to make estimates of the average contribution of the various materials to the measured radon levels indoors. There is fairly good agreement between the two. The increment of radon related dose equivalents above background are also estimated and these are combined with previously determined gamma dose equivalents and used as a basis for assessing the acceptability of the practice of using red mud as a building material. (author)

234

Proposed subcritical measurements for fresh and spent highly enriched plate type fuel assemblies  

Energy Technology Data Exchange (ETDEWEB)

A collaborative experimental research program has been established between industry and university partners to evaluate the subcritical behavior of fresh and spent highly enriched fuel assemblies at the University of Missouri Research Reactor (MURR). This proposed program will involve a series of subcritical measurements using the Oak Ridge National Laboratory (ORNL) developed {sup 252}Cf source-driven noise technique. Measurements evaluating the subcritical behavior of simple arrays of fresh MURR assemblies will be performed for evaluating the spectral effects of materials typically found in shipping casks such as lead, steel, aluminum, and boron. Also, measurements will be performed on spent assemblies to characterize physics parameters which may be useful in determining the subcritical behavior of fuels for reactivity credit of actinide burnup and fission product poisoning.

1997-09-01

235

Optimization of X-ray energy resolution from a horizontally focused single-crystal monochromator  

Energy Technology Data Exchange (ETDEWEB)

A method has been developed to optimize the energy resolution of a horizontally focusing monochromator. The method consists of determining the optimum radius of curvature of the cylindrically bent monochromator crystal by minimizing the total diffracted X-ray flux measured through an X-ray absorption foil. When measured at an absorption edge a global minimum can be identified, which corresponds to the minimum energy band accepted along the entire length of the crystal. Experimental verification of this method has been validated by comparing X-ray fluorescent scans taken for a series of crystal curvatures and by directly measuring the X-ray beam profiles at the corresponding points. The actual optical configuration and asymmetric-cut parameter of the focusing monochromator on beamline X4C at the National Synchrotron Light Source are modeled and ray tracing simulations of the optical system are compared ...

2009-02-11

236

Development and Preliminary Validation of a New Measure to Assess Shame: The Shame Inventory  

British Library Electronic Table of Contents (United Kingdom)

Research on the emotion of shame has increased significantly in recent years. However, there remains a need for more psychometrically sound measures of shame, including measures of shame in response to specific, idiographic experiences. The Shame Inventory was developed in order to assess both global feelings of shame as well as shame in response to specific life events or personal characteristics. Two studies were conducted to determine the preliminary psychometric properties of the Shame Inventory. Across both studies, results indicate that the inventory has high internal consistency, test-retest reliability, construct validity, and predictive validity. The Shame Inventory holds promise as a new measure designed to assess both global feelings of shame as well as specific shame-eliciting ...

2010-01-01

237

Design of sediment-control measures for small areas in surface coal mining. Draft report  

Energy Technology Data Exchange (ETDEWEB)

The manual provides design information for four groups of sediment control structures and treatments which are suitable for use on small areas in surface coal mining. A detailed design procedure is given for each group which will estimate the total amount of settleable solids from a small area with a sediment control structure or treatment for a specific design storm. A procedure is also given for estimating the mean annual sediment yield from a small area. Information on design, installation, maintenance and cost is given for each sediment control measure. Methods for determining the maximum allowable area for each sediment control measure and for design of combined sediment control systems are presented. The design procedures contain numerous nomographs, graphs, and worksheets to facilitate the use of the design procedure. The sediment control measures, design procedures, and materials in the manual ...

1982-04-01

238

Design of sediment-control measures for small areas in surface coal mining  

Energy Technology Data Exchange (ETDEWEB)

The manual provides design information for four groups of sediment control structures and treatments which are suitable for use on small areas in surface coal mining. A detailed design procedure is given for each group which will estimate the total amount of settleable solids from a small area with a sediment control structure or treatment for a specific design storm. A procedure is also given for estimating the mean annual sediment yield from a small area. Information on design, installation, maintenance and cost is given for each sediment control measure. Methods for determining the maximum allowable area for each sediment control measure and for design of combined sediment control systems are presented. The design procedures contain numerous nomographs, graphs, and worksheets to facilitate the use of the design procedure. The sediment control measures, design procedures, and materials in the manual ...

1982-08-01

239

Design of automatic monitoring network for the water quality management of river basin  

Energy Technology Data Exchange (ETDEWEB)

In designing automatic water quality monitoring networks for a river basin, determination of measurement locations and items is critical to the effectiveness of the total system. In this paper we studied how to decide these two design factors when a monitoring network is designed for the purpose of water quality surveillance and emergency alarm. For measurement locations, candidate sites are chosen based on the intake amount for water supply and the point sources of contamination. Then, detailed locations are decided according to the contaminant flow distance. As for measurement items, characteristics and the accident history of water pollution in the basin must be taken into account. Considering economic aspects, we proposed a two-stage measurement plan: basic components for all locations and selective ones variable for different locations. Proposed methodology is demonstrated ...

1996-04-30

240

Concentrations of radon and decay products in various underground mines in western Turkey and total effective dose equivalents  

Energy Technology Data Exchange (ETDEWEB)

Radon concentration measurements were performed for one year in 12 different boron, chromium and coal underground mines in Western Turkey. Lucas cells and nuclear track detectors were used for the measurements of radon and its decay products. The effects of parameters, such as type of mine, gallery depth and ventilation rate, on the radon concentration in mine air were examined. The radiation exposure doses of miners due to the inhalation of radon and radon daughters were determined. Gamma survey measurements were also realized together with radon measurements and the total effective dose equivalents in mSv y{sup -1} were estimated.

1998-01-01

241

Comparison of ecosystem water flux measured with the Eddy covariance- and the direct xylem sap flux method in a mountainous forest  

Energy Technology Data Exchange (ETDEWEB)

The Eddy covariance technique allows to measure different components of turbulent air fluxes, including the flow of water vapour. Sap flux measurements determine directly the water flow in tree stems. We compared the water flux just above the crowns of trees in a forest by the technique of Eddy covariance and the water flux by the xylem sap flux method. These two completely different approaches showed a good qualitative correspondence. The correlation coefficient is 0.8. With an estimation of the crown diameter of the measured tree we also find a very good quantitative agreement. (author) 3 figs., 5 refs.

1999-08-01

242

Absorption of carbonyl sulfide in aqueous methyldiethanolamine  

Energy Technology Data Exchange (ETDEWEB)

The absorption of carbonyl sulfide in aqueous methyldiethanolamine (MDEA) was studied over a range of temperatures and MDEA concentrations. MDEA is commonly used for selective absorption of hydrogen sulfide in the presence of carbon dioxide. However, sulfur in the form of COS may also be present and it is necessary that estimates of absorption rates of this compound be made. The objective of this study is to determine the physiochemical properties needed to predict COS absorption rates in aqueous MDEA. Free gas solubility and the diffusivity of COS in MDEA solutions were measured over the temperature range 15 to 40{sup 0}C for MDEA concentrations up to 30 weight per cent using the nitrous oxide analogy method. Solubilities were measured volumetrically in an equilibrium cell and diffusivities were measured using a laminar liquid jet absorber. The kinetics of the reaction between COS and MDEA were studied ...

1988-01-01

243

A concept for the experimental determination of the nucleon electric to magnetic form factor ratio at very low Q{sup 2}  

Energy Technology Data Exchange (ETDEWEB)

Stationary target measurements of the nucleon form factors have been performed with high precision down to Q{sup 2} of {approx} 0.01 GeV{sup 2} for protons (G{sub E}{sup p}) and down to {approx} 0.1 GeV{sup 2} for neutrons (G{sub M}{sup n}). Conventional extraction using cross section and polarization measurement cannot be extended to very low values of Q{sup 2} due to inherent experimental limitations. We present a proposal for a new approach to a measurement, using colliding beams, which will extend the range of possible measurement at low Q{sup 2} by several orders of magnitude over stationary target limits.

2009-05-15

244

A concept for the experimental determination of the nucleon electric to magnetic form factor ratio at very low Q2  

International Nuclear Information System (INIS)

Stationary target measurements of the nucleon form factors have been performed with high precision down to Q2 of ? 0.01 GeV2 for protons (GEp) and down to ? 0.1 GeV2 for neutrons (GMn). Conventional extraction using cross section and polarization measurement cannot be extended to very low values of Q2 due to inherent experimental limitations. We present a proposal for a new approach to a measurement, using colliding beams, which will extend the range of possible measurement at low Q2 by several orders of magnitude over stationary target limits.

2009-05-01

245

1991 ice jamming along the Saint John River: a case study  

Energy Technology Data Exchange (ETDEWEB)

Field investigations of major and damaging ice jamming on the Saint John River at Dickey, Maine , and at Sainte-Anne de-Madawaska, New Brunswick, in 1991, were described. The investigations included measurement of water surface profiles and shear wall heights at both sites. The measurements were supplemented by information from local observers and data collection agencies. Using a simplified equilibrium analysis, ice jam thickness and water level at the Dickey site was found to be generally in agreement with observed values. At Sainte-Anne-de-Madawaska sufficient data was obtained to construct and calibrate the numerical model RIVJAM which determined the configuration of the jam in nonequilibrium reaches. Use of the model enabled the successful reproduction of a measured water profile along the jam and the prediction of the approximate thickness of the jam, which was generally less than the ...

1996-04-01

246

Extraction-spectrophotometric determination of terbium in its mixture with lanthanum  

International Nuclear Information System (INIS)

A spectrophotometric study of the extraction with isobutanol of rare-earth elements in the form of complexes with quinoilizarin and N-benzene-N-phenylhydroxylamine has been made. The purpose of the study is to find out whether this reaction can be used in determining the concentration of elements in the presence of other rare-earth elements. In determining the relationship between the pH and light absorption the pH of the solution is measured after the extraction. The extraction of complexes begins at pH approximately 4 and reaches a maximum at pH7-8 (for La) and pH6-9 (for Er). The complexes underge decomposition when pH of the solution increased. The composition of complex compounds is determined by spectrophotometric methods for isomolar series, molar ratios and from the slope of logarithmic plots. Under optimal conditions (pH7.5) aAd at the measured ratio of the component for ...

1975-01-01

247

The design of hazard risk assessment matrices for ranking occupational health risks and their application in mining and minerals processing.  

Science.gov (United States)

Two hazard risk assessment matrices for the ranking of occupational health risks are described. The qualitative matrix uses qualitative measures of probability and consequence to determine risk assessment codes for hazard-disease combinations. A walk-through survey of an underground metalliferous mine and concentrator is used to demonstrate how the qualitative matrix can be applied to determine priorities for the control of occupational health hazards. The semi-quantitative matrix uses attributable risk as a quantitative measure of probability and uses qualitative measures of consequence. A practical application of this matrix is the determination of occupational health priorities using existing epidemiological studies. Calculated attributable risks from epidemiological studies of hazard-disease combinations in mining and minerals processing are used as ...

2001-03-01

248

Real-time cross-sectional averaged void fraction measurements in vertical annulus gas-liquid two-phase flow by neutron radiography and X-ray tomography techniques  

Energy Technology Data Exchange (ETDEWEB)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed ...

1995-03-11

249

Real-time cross-sectional averaged void fraction measurements in vertical annulus gas-liquid two-phase flow by neutron radiography and X-ray tomography techniques  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed ...

1995-03-01

250

Mercury-free fluorescent lighting  

Energy Technology Data Exchange (ETDEWEB)

A brief comparative review of possible mercury free fluorescent lighting technologies is presented, including rare-gas positive column discharges, molecular discharges, and dielectric barrier discharges. Detailed experimental results on xenon positive column discharges will then be considered. In order to judge whether xenon-based discharges are a viable UV source it is necessary to measure the radiant emittance (power per unit area) for the vacuum ultraviolet (VUV) resonance xenon emission at 147 nm. Two techniques to determine the VUV radiant emittance have been developed and applied to xenon discharges. One method combines the measured resonance level density using absorption spectroscopy and a calculation of the trapped decay rate for the resonance radiation to arrive at the radiant emittance at 147 nm. A second method utilizes a direct measurement of the radiance (power per unit area per unit solid ...

1996-05-01

251

Bidirectional reaction steps in metabolic networks: II. Flux estimation and statistical analysis.  

Science.gov (United States)

Metabolic carbon labelling experiments enable a large amount of extracellular fluxes and intracellular carbon isotope enrichments to be measured. Since the relation between the measured quantities and the unknown intracellular metabolic fluxes is given by bilinear balance equations, flux determination from this data set requires the numerical solution of a nonlinear inverse problem. To this end, a general algorithm for flux estimation from metabolic carbon labelling experiments based on the least squares approach is developed in this contribution and complemented by appropriate tools for statistical analysis. The linearization technique usually applied for the computation of nonlinear confidence regions is shown to be inappropriate in the case of large exchange fluxes. For this reason a sophisticated compactification transformation technique for nonlinear statistical analysis is developed. Statistical analysis is then ...

1997-07-01

252

Determination of two-phase flow parameters for nuclear fuel channels using a real-time neutron radiography method  

Energy Technology Data Exchange (ETDEWEB)

Multi-dimensional modelling of two-phase flow requires accurate constitutive relationships for interfacial parameters such as interfacial heat transfer, void fraction distribution, interfacial area, etc. However, existing diagnostic systems for measurement of two-phase flow parameters have difficulty measuring two or three-dimensional void distributions required for determination of interfacial parameters. In this work, a Real-Time Neutron Radiography (RTNR) system is developed for non-intrusive measurement of two-phase flow parameters in nuclear fuel channels at low thermal neutron fluxes (on the order of 10{sup 6}n/cm{sup 2}-s). This advanced radiation technique has the advantage of measuring two-phase flow in 3 1/2 dimensions (x,{integral}dy,t) where the 1/2 dimension refers to an integrated or averaged space dimension. Pipe flow channels, annulus flow channels, MAPLE-type ...

1995-07-01

253

Determination of two-phase flow parameters for nuclear fuel channels using a real-time neutron radiography method  

International Nuclear Information System (INIS)

Multi-dimensional modelling of two-phase flow requires accurate constitutive relationships for interfacial parameters such as interfacial heat transfer, void fraction distribution, interfacial area, etc. However, existing diagnostic systems for measurement of two-phase flow parameters have difficulty measuring two or three-dimensional void distributions required for determination of interfacial parameters. In this work, a Real-Time Neutron Radiography (RTNR) system is developed for non-intrusive measurement of two-phase flow parameters in nuclear fuel channels at low thermal neutron fluxes (on the order of 10"6n/cm"2-s). This advanced radiation technique has the advantage of measuring two-phase flow in 3 1/2 dimensions (x,#integral#dy,t) where the 1/2 dimension refers to an integrated or averaged space dimension. Pipe flow channels, annulus flow channels, MAPLE-type nuclear fuel ...

1346-01-01

254

Statistical comparison of the effect of relative and absolute humidity on fixed-bed carbon adsorption capacity. Report for January 1987-July 1988  

Energy Technology Data Exchange (ETDEWEB)

This paper describes statistical methods used to evaluate data for toluene (at several typical operating temperatures and humidity levels) and to determine which measure of humidity (relative or absolute) is more important in determining carbon adsorption efficiency. The water content of a solvent-laden stream is critical for its control via carbon adsorption, especially at relative humidities about 50-70%. (Relative humidity is the percent of saturation: absolute humidity is the total water content.)

1989-01-01

255

Quality engineering and control. Semiannual progress report, May-October 1979  

International Nuclear Information System (INIS)

The following are reported: colorimetric determination of Ti in Cr, decontamination of metals by anodic dissolution, computer code for x-ray peak identification, gel-permeation chromatography of CoRezyn 1664 polyester resin, infrared monitoring of gases and vapors, particle size analysis of dusts, nondestructive analysis of Oralloy for removable alpha contamination, dissolution (digestion) of high-fired oxides, assay of U in a Pu-U alloy, measurement of oxide thickness on Pu metal by x-ray diffraction, analysis of precipitated Pu peroxide, differentiation of Dowex SBR and 11 resins, and determination of Pu solubility in simulated lung fluid.

256

Prediction of the compressive strength of vertebral bodies of the lumbar spine by quantitative computed tomography.  

Science.gov (United States)

The ultimate compressive strength of 36 thoracolumbar vertebrae was determined experimentally. In addition, the trabecular bone mineral content was measured by single energy quantitative computed tomography. The areas of fractured endplates were also determined by computed tomography. The results show that a linear relationship exists between the compressive strength and the product of bone density and endplate area. These data allow an in vivo prediction of vertebral body strength using a noninvasive method with a standard error of estimate amounting to less than 0.95 kN. PMID:3212488

1988-01-01

257

New method for determining the energy gap of a superconductor using the maximum in differential conductance of the electron tunneling spectrum  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a new method for the determination of the energy gap of superconductors. The V/sub max//kT versus ..delta../kT curve was calculated from tunneling theory. The maximum voltage in differential conductance V/sub max/ was measured from the electron tunneling spectrum. From V/sub max//kT and the curve, one can easily calculate the energy gap value ..delta... This method is simple, and the accuracy almost approaches that of the curve-fitting method.

1986-07-01

258

New method for determining the energy gap of a superconductor using the maximum in differential conductance of the electron tunneling spectrum  

International Nuclear Information System (INIS)

This paper presents a new method for the determination of the energy gap of superconductors. The V/sub max//kT versus #DELTA#/kT curve was calculated from tunneling theory. The maximum voltage in differential conductance V/sub max/ was measured from the electron tunneling spectrum. From V/sub max//kT and the curve, one can easily calculate the energy gap value #DELTA#. This method is simple, and the accuracy almost approaches that of the curve-fitting method.

259

New method for determining the energy gap of a superconductor using the maximum in differential conductance of electron tunneling spectrum  

Energy Technology Data Exchange (ETDEWEB)

A new method for determining the energy gap of a superconductor using the maximum in the differential conductance curve of electron tunneling spectrum is given in this paper. The V/sub max//kT versus ..delta../kT curve was calculated from tunneling theory. V/sub max/, the voltage of the conductance maximum, can be measured from electron tunneling spectrum. ..delta../kT can be found from this curve, then the energy gap ..delta.. can be calculated. This method is simple, fast and accurate. The accuracy almost approaches that of the curve fitting method.

1986-02-01

260

Measurement of the Matrix Element for the Decay $\\eta^{\\prime} \\to \\eta \\pi^+\\pi^-$  

CERN Document Server

The Dalitz plot of $\\eta^{\\prime} \\to \\eta \\pi^+ \\pi^-$ decay is studied using $(225.2\\pm2.8)\\times 10^6$ $\\jpsi$ events collected with the BESIII detector at the BEPCII $e^+e^-$ collider. With the largest sample of $\\eta^{\\prime}$ decays to date, the parameters of the Dalitz plot are determined in a generalized and a linear representation. Also the branching fraction of $\\jpsi \\to \\gamma \\eta^{\\prime}$ is determined to be $(4.84\\pm0.03\\pm0.24)\\times 10^{-3}$, where the first error is statistical and the second systematic.

2010-01-01

261

Certified Reference Materials (CRM) for the quality control of metals chemical forms determinations in environment, in support to the European Union legislation; Materiaux de reference certifies pour le controle de qualite des determinations de formes chimiques des metaux dans l`environnement, en soutien a la legislation de l`Union Europeenne  

Energy Technology Data Exchange (ETDEWEB)

This work gives a global view of legislations in which are included metals chemical states, briefly recalls the conditions to be respected for the CRM (Certified Reference Materials), and describes the results of some current plans for the Norms, Measures and Tests program. (O.M.) 23 refs.

1997-03-01

262

Capability of the PAMELA Time-Of-Flight to identify light nuclei: results from a beam test calibration  

CERN Document Server

PAMELA is a space telescope orbiting around the Earth since June 2006. The scientific objectives addressed by the mission are the measurement of the antiprotons and positrons spectra in cosmic rays, the hunt for anti-nuclei as well as the determination of light nuclei fluxes from Hydrogen to Oxygen in a wide energy range and with very high statistics. In this paper the charge discrimination capabilities of the PAMELA Time-Of-Flight system for light nuclei, determined during a beam test calibration, will be presented.

2008-01-01

263

Atmospheric corrosion in Gran Canaria specifically meteorological and pollution conditions  

Energy Technology Data Exchange (ETDEWEB)

Carbon steel, copper, zinc and aluminium samples were exposed in different sizes with known ambient parameters in Gran Canaria Island and atmospheric corrosion was investigated. Weight-loss measurements used to determine corrosion damage were complemented with metallographic and XP S determination in order to characterize the structure and morphology of surface corrosion products. The ambient aggressiveness could be well evaluated from meteorological and pollution data. All atmospheric corrosion and environmental data were statistically processed for establishing general corrosion damage functions for carbon steel, copper, aluminium and zinc in terms of Gran Canaria extreme meteorological and pollution parameters. (Author)

1998-12-31

264

A Geometrical Model for Non-Zero $\\theta_{13}$  

CERN Document Server

Based on Friedberg and Lee's geometric picture by which the tribimaximal PMNS leptonic mixing matrix is constructed, namely corresponding mixing angles correspond to the geometric angles among the sides of a cube. We suggest that the three realistic mixing angles which slightly deviate from the values determined for the cube, are due to a viable deformation from the perfectly cubic shape. Taking the best fitted results of $\\theta_{12}$ and $\\theta_{23}$ as inputs, we determine the central value of $\\sin^22\\theta_{13}$ should be 0.0238 with a relatively large error tolerance, this value lies in the range of measurement precision of the Daya Bay experiment.

2011-01-01

265

Feasibility of /sup 252/Cf source driven neutron noise measurements in water moderated reactors  

Energy Technology Data Exchange (ETDEWEB)

Previous experiments in fast critical assemblies demonstrated a method of determining reactivity from power spectral density measurements with /sup 252/Cf. This method determines reactivity from properties of the reactor only at the subcritical state of interest, thus it does not require a calibration near delayed criticality. The interpretation of the measured data to obtain reactivity does not require knowledge of the relative or absolute values of the source intensity, knowledge of the detection efficiencies, or knowledge of the detection instrumentation frequency responses. An experiment was performed at the Pool Critical Assembly to evaluate the possibility of /sup 252/Cf source driven neutron noise spectral density measurements in light water moderated reactors. This experiment showed that using commercially available detectors, such measurements can be ...

1980-01-01

266

Using interpubic distance for sexing manakins in the field  

British Library Electronic Table of Contents (United Kingdom)

ABSTRACT. Field methods for determining the sex of birds are often limited due to morphometric overlap between sexes, intermediate plumages, seasonality, and reliance on subjective age classification. Interpubic distance, characterized in birds as the distance between the distal ends of the pubic bones, has not been formally tested as a method for determining the sex of birds, despite references among parrot breeders and the frequent use of analogous measurements in mammals. We developed a harmless and easily performed field method for measuring interpubic distance in studies involving bird capture, and compared the interpubic distances of known sex White-ruffed Manakins (Corapipo altera), Orange-collared Manakins (Manacus aurantiacus), and Blue-crowned Manakins (Lepidothrix coronata) to e...

2010-01-01

267

Use of portable HPGE detector and multichannel analyzer for in-situ gamma spectrometry of soil  

International Nuclear Information System (INIS)

Measurement of fission and activation products in the soil or over a plane grass land of a nuclear power station environment is required to find out the long term changes. The inventory of radionuclides in the soil is routinely determined by soil sampling, processing and gamma spectrometry in the laboratory. The method although is proven and accurate is time consuming and largely dependent on homogenous distribution. Therefore, an alternative and rapid method of in-situ gamma spectrometry using portable devices was standardized to determine the concentration of radionuclides in soil, for regular environmental monitoring as well as during emergency condition. The paper presents the methodology, ready to use factors and compares the results of a few measurements made in the environment of Tarapur Atomic Power Station by both in-situ and laboratory methods. (author)

2005-11-23

268

Thermal noise as a spectroscopic tool to determine transport properties  

British Library Electronic Table of Contents (United Kingdom)

The utilization of thermal fluctuations or Johnson/Nyquist noise as a spectroscopic method to determine transport properties in conductors or semiconductors is developed. The autocorrelation function is obtained from power spectral density measurements thus enabling electronic transport property calculation through the Green-Kubo formalism. This experimental approach is distinct from traditional numerical methods such as molecular dynamics simulations, which have been used to extract the autocorrelation function and directly related physics only. This work reports multi-transport property measurements consisting of the electronic relaxation time, resistivity, mobility, diffusion coefficient, electronic contribution to thermal conductivity and Lorenz number from experimental data. Double va...

2009-01-01

269

The determination of the tuning of a Power System Stabilizer (PSS). De bepaling van de instelling van een Power System Stabilizer  

Energy Technology Data Exchange (ETDEWEB)

By means of an analogous simulator, which can simulate a power supply system, a method to determine the transfer function of a Power System Stabilizer (PSS) is developed. The purpose of the PSS is to damp unwanted electro-mechanical oscillations. The method is very systematic and there is no need for specified values of the parameters used in the system. It is assumed that the power generator system is linear for small variations. The system can be considered to be a black box. Measurements executed by means of this method are completely controlled by the person who enforces the measurement. By applying this method carefully, irregularities are almost out of the question. The equipment necessary are a PC with two AD-ports and an adjustable sinus-generator. A comparison is made with a more traditional method, in which a spectrum analyzer is used. 4 figs., 7 refs.

1992-10-01

270

Temperature and time-dependence of the elastic moduli of Pu and Pu-Ga alloys  

International Nuclear Information System (INIS)

In previous work, on cooling from 300 K to 10 K the elastic moduli for both #alpha#- and #delta#-Pu dropped 30%. This large change may reflect effects of 5f-electron localization. In this work, the elastic moduli at ambient temperature of several Pu-Ga alloys were measured using resonant ultrasound spectroscopy (RUS). The strong temperature dependence of the bulk and shear modulus and the temperature independence of Poisson's ratio was confirmed and the upper temperature limit for #alpha#-Pu was extended to 360 K. Measurements of the time dependence of the shear moduli of Pu and Pu-2.36 at.% Ga were determined with high precision as a function of time and temperature. Using a model for time dependence of point defects, we determined the exponential time constant at ambient temperature for such variations. The low temperature results are consistent with Fluss .

2007-10-11

271

Retention of ring structure in cyclopentane and alkylcyclopentane molecular cations  

Energy Technology Data Exchange (ETDEWEB)

All measurements were made with the NBS high-pressure photoionization mass spectrometer. The fractional of C/sub 5/H/sub 10//sup +/ions in a cyclopentane-cyclohexane mixture were determined as a function of pressure in order to define the fraction of the ions which did charge exchange with cyclohexane; i.e. the fraction which remained cyclic after ionization. The data for mixtures of various compositions (2.5 to 10% cyclohexane) are summarized for measurements performed at 10.62 eV: (a) 292K, > 96% cyclic; 347 K, greater than or equal to 94% cyclic; 386 K, 84 +- 4% cyclic; and 412 K, 78 +- 6% cyclic; entropy, enthalpy, and activation energy were determined; 10.49 eV was obtained as the ionization potential of cyclopentane. 1 figure.

1980-01-01

272

Optimal detector deployment for the CANDU-600 pressurized heavy water reactor  

Science.gov (United States)

An optimal deployment pattern of flux mapping detectors for a Canada uranium-deuterium (CANDU)-600 pressurized heavy water reactor (PHWR) is determined by obtaining an optimal feedback relationship between flux measurements and zone controllers. The reactor core is modeled with a time-dependent two-group, two-dimensional diffusion equation, and flux perturbation are expressed by model expansions. The modal expansion coefficients are used as elements of the state vector representing the system dynamics. An optimal feedback matrix connecting the flux measurement vector to the control vector is derived by minimizing a quadratic performance index involving both the state and control vectors. We obtain the detector effectiveness in terms of the optimal feedback matrix and determine optimal detector locations for the Wolsung Unit 1 reactor in Korea. We have tested the methodology through evaluation of flux ...

1992-01-01

273

New pulse sequence for simultaneous T1, T2, and RHO determination in whole-body proton MR imaging  

International Nuclear Information System (INIS)

A newly developed method to support tissue characterization in routine MR imaging is presented. It represents a compromise between the practical requirements of clinical routine (short measurement time, multisection imaging) and the necessary accuracy of the relaxation parameter evaluation. The sequence employed is a modification of the PHAPS technique and works with two excitation pulses. It allows the simultaneous acquisition of all measurement data for the subsequent T1, T2, and rho evaluations. T1 is determined with a specially designed computation formula based on four signal ratios. A multiexponential T2 analysis is performed with use of 28 echoes. From these parameters, relative proton density can be computed.

274

Instrumental neutron activation analysis of copper-molybdenum ores for molybdenum content determination  

International Nuclear Information System (INIS)

An instrumental neutron activation technique of determining molybdenum in ores is based on measuring gamma-activity of the "9"9Mo isotope with the use of planar and coaxial semiconductor spectrometers. A lot consisting of 50 portions, 0.5 g each, is being irradiated for 10 hours by a flow of neutrons with the density of 10"1"2 n/cm"2xsec. On the lot being allowed to stay for 3-4 days, its activity is measured during 1-5 minutes. Monoethalons based upon phenol-formaldehyde resin are used as standards. The sensitivity of the technique is 10"-"4%, reproducibility error being not higher than 10%, efficiency up to 50 portions for a working shift.

275

Experimental determination of single and two-phase flow pressure drop across a PWR core degraded by accident  

International Nuclear Information System (INIS)

The present paper deals with the experimental determination of pressure drop across a four-cusped vertical channel. This geometry represents, ideally, the blockage condition in a typical pressurized water reactor with core degraded by accident. Experiments were performed for both single and two-phase flow. Water was utilized for the single-phase measurements whilst simultaneous flow of air and water simulated the steam-water flow. Observation of the prevailing two-phase flow regime was carried out, so that its mechanism could be fully understood. The averaged void fraction was also measured, by the gamma-ray attenuation technique. A wide range of water and air mass flow rates was covered, so that all flow conditions, possible to exist in a reactor with LOCA, could be investigated. New correlations for pressure drop are proposed. (Author).

1986-03-17

276

Autonomous multi-sensor micro-system for measurement of ocean water salinity  

British Library Electronic Table of Contents (United Kingdom)

This paper describes the design, fabrication and application of a micro-fabricated salinity sensor system. The theoretical electrochemical behaviour is described using electrical equivalent diagrams and simple scaling properties are investigated analytically and numerically using finite element method (FEM). The chip design and fabrication is described and measurement results of two different electrode designs are presented. The 4mm Formula Not Shown 4mm multi-sensor allows for salinity determination with an accuracy of Formula Not Shown 0.5psu through determination of the electrical conductivity, temperature and pressure with accuracies of Formula Not Shown 0.6mS, Formula Not Shown 0.065 Formula Not Shown C and Formula Not Shown 0.05bar, respectively.

2008-01-01

277

A method for measuring effective radon diffusion coefficients in radon barriers by using modified Lucas cells  

Energy Technology Data Exchange (ETDEWEB)

Radon proof barriers are used for lowering of radon transport from the soil into the house and the determination of the radon diffusion coefficient is an important parameter to be determined in order to design the minimal thickness of the radon proof insulation. A method has been developed in our laboratory by using modified Lucas cells connected to a radon source and tightly closed onto the top by the tested membranes whose radon diffusion coefficients are being measured. Solving the time-dependent differential equation for radon diffusion in the membrane for well-defined experimental conditions the effective radon diffusion coefficient of the insulating material can be evaluated by comparing the radon concentration decrease in the cell for the first hours with the well-known radioactive decay. First results obtained in several preliminary tests carried out with a parafilm M barrier and two polyethylene membranes are shown ...

2005-01-01

278

Use of neutron and gamma ray spectral measurements and calculations to obtain dosimetric information for DT neutrons  

Energy Technology Data Exchange (ETDEWEB)

Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, ...

1983-01-01

279

Use of neutron and gamma ray spectral measurements and calculations to obtain dosimetric information for DT neutrons  

International Nuclear Information System (INIS)

Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, ...

7871-01-01

280

Remote temperature inversion sensor  

International Nuclear Information System (INIS)

In conducting aircraft surveys for uranium, it is found that temperature inversions can give spurious results because they promote accumulation of radon gas in the atmosphere. The "2"1"4Bi (daughter product of radon) gamma-rays detected from the atmosphere-borne radon are difficult to separate from the "2"1"4Bi gamma-rays originating from the ground, and providing a signature for uranium deposits. The purpose of the present study was to examine the feasibility of making remote temperature soundings of the atmosphere below a low-flying aircraft (140 m or less above ground) by the inversion of radiance measurements taken in the 15-micron carbon dioxide absorption band. Such measurements would identify those temperature inversion conditions possibly leading to an unacceptably large background of gamma-rays from the atmospheric radon. Thus, the incidence of spurious aerial survey data could be greatly reduced. An atmospheric model was set up and ...

1977-01-01

281

Proton G{sub E}/G{sub M} from beam-target asymmetry  

Science.gov (United States)

The ratio of the proton's electric to magnetic form factor, G{sub E}/G{sub M}, can be extracted in elastic electron-proton scattering by measuring cross sections, beam-target asymmetry, or recoil polarization. Separate determinations of G{sub E}/G{sub M} by cross sections and recoil polarization observables disagree for Q{sup 2}>1 (GeV/c){sup 2}. Measurement by a third technique might uncover an unknown systematic error in either of the previous measurements. The beam-target asymmetry has been measured for elastic electron-proton scattering at Q{sup 2} = 1.51 (GeV/c){sup 2} for target spin orientation aligned perpendicular to the beam momentum direction. This is the largest Q{sup 2} at which G{sub E}/G{sub M} has been determined by a beam-target asymmetry experiment. The result, {mu}G{sub E}/G{sub M}=0.884{+-}0.027{+-}0.029, is compared to previous ...

2006-09-15

282

Physical properties of Ti/sub 50/Be/sub 40/Zr/sub 10/ glass  

Science.gov (United States)

Continuous metallic glass ribbons were produced by mejans of liquid-quenching at rates >10/sup 50/C/s. The ribbons, typically 30 ..mu..m thick and 1 to 2 mm wide, were determined to be glassy by X-ray diffraction (XRD) employing CuK..cap alpha.. and MoK..cap alpha.. radiation. Mechanical properties of the as-quenched product were determined by measurements of hardness, tensile strength and Young's modulus. The Vicker's diamond pyramid microhardness (H/sub V/) was measured on epoxy mounted samples using a Lietz Miniload instrument with a 100 g load. Tensile tests were conducted in an Instron machine using specimens which were hand-polished to produce smooth, parallel sides. Young's modulus (E) is given by the relationship rho V/sub E/sup 2//. V/sub E/, the velocity of extensional mode waves, was measured by the pulse-echo technique using a Panametrics ...

1977-09-01

283

Cross-sectional void fraction distribution measurements in a vertical annulus two-phase flow by high speed X-ray computed tomography and real-time neutron radiography techniques  

Energy Technology Data Exchange (ETDEWEB)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,{theta}) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.

1995-09-01

284

Cross-sectional void fraction distribution measurements in a vertical annulus two-phase flow by high speed X-ray computed tomography and real-time neutron radiography techniques  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,#theta#) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.

1995-09-01

285

Coupled neutron - #gamma#-ray diffraction: A method for accurate measurement of strains. Application to the study of the ferroelectric phase transition of KH_2PO_4  

International Nuclear Information System (INIS)

A method that employs simultaneous neutron and #gamma#-ray diffraction techniques is proposed for accurate measurements of strains with or without an applied electric field (0-100 kV m"-"1). Instead of an absolute determination of the position of the neutron Bragg peak, a relative measurement of the neutron and #gamma# peak positions is used and allows a determination of the lattice-parameter changes with an accuracy of within 2 x 10"-"6. This technique avoids systematic errors originating in sample rotations by taking advantage of a reference directly related to the crystal lattice. The method appears to be particularly important for crystals that exhibit structural phase transitions, as demonstrated by the measurement of the strain U_x_x in KH_2PO_4 crystals as a function of temperature and applied electric field. In this case the errors would amount to #+-#20%. The results ...

1987-12-01

286

State-of-the-art in permeability determination from well log data: Part 1-A comparative study, model development  

Energy Technology Data Exchange (ETDEWEB)

This study discusses and compares, from a practical point of view, three different approaches for permeability determination from logs. These are empirical, statistical, and the recently introduced virtual measurement methods. They respectively make use of empirically determined models, multiple variable regression, and artificial neural networks. All three methods are applied to well log data from a heterogeneous formation and the results are compared with core permeability, which is considered to be the standard. In this first part of the paper we present only the model development phase in which we are testing the capability of each method to match the presented data. Based on this, the best two methods are to be analyzed in terms of prediction performance in the second part of this paper.

1995-12-31

287

Effect of mass transport on the determination of corrosion rates from polarization measurements  

Energy Technology Data Exchange (ETDEWEB)

Many methods have been proposed for the determination of the corrosion current density from polarization curves; the two most commonly used ones are the three-point method and the curve-fitting method. The basis of these methods is a polarization equation that was derived for the complete absence of mass-transport effect or considers the cathodic partial reaction to be under complete mass-transport control. The mixed-control case has been much less investigated, even though this case may quite frequently reflect practical situations. A completely generalized polarization equation is proposed that can be used as a basis for curve-fitting data evaluation under any conditions. This equation was used to determine the error caused by the neglect of mass-transport effect in conventional data evaluation.

1986-10-01

288

Determination of selected elements by radionuclide X-ray fluorescence analysis after the separation on different kinds of sorption materials  

British Library Electronic Table of Contents (United Kingdom)

This paper aimed to the evaluation of different kinds of sorbent material preparation and to the evaluation of their characteristics at different pH conditions by X-ray fluorescence analysis. This method is suitable for identification and determination of elements in samples of different character, state and origin because it is a polycomponent, non-destructive, fast and simple analytical method. Moreover, it allows time-advantageous and reliable measurements. This paper studies problems concerning the determination of some selected elements (Mn, Fe, Ni, Cu, Zn, Pb) in pharmaceutical samples of sodium chloride in the solid state as well as in its solution by sorption on chelating extraction membrane 3M Empore? and on the strongly acidic ion-exchanger Dowex 50Wx8. Conditions for the most ef...

2008-01-01

289

Determination of band offsets and subband levels for a GaInP/AlGaInP quantum well by photoreflectance using a InGaP laser diode  

International Nuclear Information System (INIS)

The band offsets and subband levels in a double quantum well layer for a 660 nm-Ga_0_._4In_0_._6P/(Al_0_._5Ga_0_._5)_0_._5In_0_._5P quantum well laser are determined by photoreflectance using a 410 nm InGaN laser with current modulation at room temperature. The subband levels are analyzed by numerical calculation of the Schroedinger equation for the layer structure by varying the conduction band offset and compared with the measured photoreflectance spectra. The conduction band offset ratio is determined to be 0.5+0.03. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

2009-06-01

290

Clinical application of dosimetry in electron beam therapy  

International Nuclear Information System (INIS)

In everyday radiotherapy we must carry out the determination of absorbed dose measurement according to JARP's protocol. We explained an outline of JARP's 1974 and 1986 protocol in electron beam therapy, and mentioned it about the matter that should examined. To use it easily in clinic, a simplified procedure based on precisely to JARP's 1986 protocol is practical, the character of this procedure settles briefly the determination of mean incident energy of electron beams and get ready to table of ionization to absorbed dose conversion factor for various ionization chamber. Also, this procedure almost not influence on the accuracy of determination. We described systematically practical procedure for requisite absorbed dose calculation in a patient in electron beam therapy. (author).

291

CANDU 6 fuel behaviour in power ramp conditions  

International Nuclear Information System (INIS)

The facilities in the Institute for Nuclear Research at Pitesti allow the testing, handling and examination of nuclear fuel and irradiated materials. The most important facilities are the TRIGA Steady State Research and Material Test Reactor and the Post-Irradiation Examination Laboratory (PIEL). The purpose of this work is to determine by post-irradiation examination, the behavior of CANDU fuel, irradiated in 14 MW TRIGA reactor. The fuel was irradiated in power ramp conditions. The results of post-irradiation examination are: - Visual inspection and photography of the outer appearance of sheath; - Profilometry (diameter, bending, ovality) and length measuring; - Determination of axial and radial distribution of the fusion products activity by gamma scanning and tomography; - Microstructural characterization by metallographic and ceramographic analyzes; - Mechanical properties determination. The data ...

2009-10-12

292

Application of nuclear analytical methods in determining heavy metals in a welder's working environment  

International Nuclear Information System (INIS)

The problems are discussed of using radionuclide X-ray fluorescence analysis (the most frequently used source is "2"4"1Am) and neutron activation analysis for monitoring the chemical quality of the working environment of a welder. Elements determinable by these methods are listed and the advantages of the methods stated with regard to speed, simplicity and appropriate accuracy of measurement together with commercial availability of the instruments. Welding as a source of harmful substances is assessed by determination of the amount of chromium in aerosols generated by welding austenitic chromium-nickel steels. The described methods allow to obtain a complex image of the chemical nature of welding aerosols and to understand the mechanism of their impact on the human organism. (J.C.).

1986-01-01

293

A semi-micro combustion assembly for the determination of carbon and hydrogen in actinide compounds  

International Nuclear Information System (INIS)

A rapid combustion unit (Baird and Tatlock) incorporating a combustion chamber provided with baffle plates for complete combustion of the sample without the use of a catalyst has been assembled in a glove box for the determination of carbon and hydrogen in actinide complexes. The unit has been modified employing a movable electric furnace and a proportional temperature controller, for decomposition of the sample at desired heating rates. The set-up was standardised employing various reference materials such as benzoic acid, acetanilide, sulphanilamide and 1-chloro 2:4 dinitrobenzene and the standard deviation in the measurements evaluated. It has also been used successfully for the determination of carbon in uranium carbide and carbon and hydrogen in some uranyl-#beta#-diketone-amine N-oxide complexes and in plutonium(IV) oxalate. (auth.).

1982-09-01

294

A semi-micro combustion assembly for the determination of carbon and hydrogen in actinide compounds  

International Nuclear Information System (INIS)

A rapid combustion unit (Baird and Tatlock) incorporating a combustion chamber provided with baffle plates for complete combustion of the sample without the use of a catalyst has been assembled in a glove box for the determination of carbon and hydrogen in actinide complexes. The unit has been modified employing a movable electric furnace and a proportional temperature controller, for decomposition of the sample at desired heating rates. The set-up was standardised employing various reference materials such as benzoic acid, acetanilide, sulphanilamide and 1-chloro 2:4 dinitrobenzene and the standard deviation in the measurements evaluated. It has also been used successfully for the determination of carbon in uranium carbide and carbon and hydrogen in some uranyl-#beta#-diketone-amine N-oxide complexes and in plutonium(IV) oxalate. (auth.).

2006-09-18

295

Isolation and determination of "9"0Sr, "2"2"6Ra, "2"2"8Ra and "2"1"0Pb in food  

International Nuclear Information System (INIS)

A procedure is described for the isolation and determination of "9"0Sr, "2"2"6Ra, "2"2"8Ra and "2"1"0Pb in food. These nuclides are highly radiotoxic, above all for babies and children. Samples are dry ashed, alkali metals are removed as carbonates. Separation from other matrix ions and separation of Ra, Sr and Pb can be achieved with a column of Sr-Spec, an immobilized crown ether. For activity measurements membrane filters with SrSO_4, Ba(Ra)SO_4 and PbS are prepared. Ra is determined by gamma-spectrometry, "9"0Sr and "2"1"0Pb are determined by low-level-betacounting. The determination limits are 10 mBq/kg for "9"0Sr and "2"1"0Pb and 50 mBq/kg for "2"2"6Ra and "2"2"8Ra. The procedure is useful for all kinds of foodstuff. (orig.).

296

Epidemiologic studies of coronary heart disease and stroke in Japanese men living in Japan, Hawaii, and California: demographic, physical, dietary, and biochemical characteristics  

International Nuclear Information System (INIS)

These summary descriptive data of ethnically similar cohorts of indigenous and migrant Japanese males have shown similarities or slight differences in characteristics wholly or largely genetically determined, such as blood groups, stature, and skeletal size. Differences have been noted in characteristics largely environmental or behavioral, such as diet and cigarette smoking habit, as well as in characteristics determined by a varying mixture of genetic and environmental influences, such as weight, blood pressure, glucose tolerance, and serum lipid and uric acid levels. Detailed analyses of the distributions of laboratory variables, of dietary data obtained by different methods, and of correlations among laboratory, dietary, physical, and demographic variables are currently in progress. Also part of the study plan are determinations of disease prevalence from evaluation of examination, laboratory, and electrocardiographic ...

297

Determination of time-dependent void fraction distribution in bubbly two-phase flow by a real-time neutron radiography technique  

Energy Technology Data Exchange (ETDEWEB)

Radiographic images generated by the real-time neutron radiography system (RTNR) are analyzed by customized image processing software of the determination of instantaneous void fraction distribution. The cross-sectional averaged axial void fraction profiles and the two-dimensional void fraction profiles are determined simultaneously for each image. Various flow regimes are generated to determine if the RTNR system can accurately predict the void distribution in the radial, axial, and temporal coordinates. The results show the RTNR system correctly determines the void fraction distribution for each flow regime; however, accuracy decreases with decreasing void fraction. For net water thicknesses > 1.0 cm, the accuracy decreases with increasing water thickness due to the extreme sensitivity of thermal neutron interactions with light water. Heavy water is a more suitable fluid than light water for void ...

1995-01-01

298

Studies of a Poenitz-type black neutron detector as a neutron flux monitor  

Energy Technology Data Exchange (ETDEWEB)

A black neutron detector of novel design has been constructed and tested as a neutron flux monitor. The neutron time-of-flight (TOF) technique was used to measure the zero degree neutron spectrum from a subnanosecond pulsed proton beam on a thick metallic lithium target. We describe the detector, discuss the shielding arrangement and electronics, determine the low-energy cut-off. We calculate the efficiency, show spectra and compare measured zero degree differential cross-section of the {sup 7}Li(p, n{sub 0}){sup 7}Be reaction with recommended published cross-sections. (orig.).

1997-04-01

299

Some sources of error in property indices for coke-oven charge  

Science.gov (United States)

The author points out that errors in certain measurements are preventing improvements in coke: thermocouples (errors caused by the thermocouple installation and variations in the temperature of the cold junctions); dilatometers (errors caused by size of heating block and differences in starting temperature led to differences between two instruments); errors in measuring the bulk density of the coking charge. The elimination of these sources of error in determinations of the technological and physical properties of coke oven charge should assist in the study of other problems which are delaying improvements in blast furnace coke production.

1981-01-01

300

Solution of the orthopositronium lifetime puzzle  

CERN Document Server

The intrinsic decay rate of orthopositronium formed in SiO/sub 2/ powder is measured using the direct 2 gamma correction method such that the time dependence of the pick-off annihilation rate is precisely determined. The decay rate of orthopositronium is found to be 7.0396+or-0.0012(stat.)+or-0.0011(sys.)/ mu s/sup -1/, which is consistent with our previous measurements with about twice the accuracy. Results agree well with the O( alpha /sup 2/) QED prediction, and also with a result reported very recently using nanoporous film.

2004-01-01

301

Precise measurement of theta_13 at Daya Bay  

CERN Document Server

The Daya Bay Reactor Neutrino Experiment is designed to determine the yet unknown neutrino mixing angle theta_13 by measuring the disappearance of electron antineutrinos from several nuclear reactor cores, using multiple underground detectors at different baselines to minimize systematic errors and to suppress the cosmogenic background. The civil construction has begun since October 2007, enabling first commissioning data in 2009, and full data taking will begin in late 2010. The planned sensitivity in sin^2 (2theta_13) of better than 0.01 at 90% CL will be achieved in three years of data-taking. I will present an overview and current status of the experiment.

2008-01-01

302

Nuclear data activity at Atomic Energy Research Establishment, Savar, Dhaka  

Energy Technology Data Exchange (ETDEWEB)

The nuclear data activity at AERE, Savar is briefly presented in this paper. Major thrust is on the customization of cross section libraries for general purpose reactor and shielding calculations. The processing codes that are available are NJOY91.91, some AMPX-Modules and the modules in SCALE-PC. Recent measurements on cross section data over the energy range 13-15 MeV at the Institute of Nuclear science and Technology have been reviewed. Measurements and calculations are based on the determination of excitation functions of neutron induced reactions on the elements and isotopes of FRT-relevant structural materials. (author).

1995-03-01

303

Multi-frequency binary sequence testing at FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

The multi-frequency binary sequence experimental technique has been implemented at the Fast Flux Test Facility for routine surveillance activities. The frequency content of the standard rod-movement sequence has been shown to be sufficient to normalize the data at moderate frequencies. This obviates the need for auxiliary calibration measurements and provides the reactivity worth of the test control rod. Analyses of a series of tests conducted in 1986 illustrate that the rod worths inferred from the tests are consistent with zero-power measurements. Also, the dependence of the prompt feedback time constant on reactor conditions was determined.

1988-09-18

304

Magnetization reversal phenomena and domain wall behaviours in nanostructured magnetic systems  

International Nuclear Information System (INIS)

Several recent experiments on micro- (or nano-) structured samples of ferromagnetic materials are introduced. Magnetization reversal phenomena are investigated on submicron wire samples of trilayer structure using the giant magnetoresistance effect. Domain wall movements are sensitively monitored by resistivity measurements and the velocity of propagation is determined. The contribution of domain wall to the resistivity is argued from the results on artificially designed samples of a spring-magnet system. In circular dots of permalloy, the existence of vortex magnetization is confirmed and the reversal of the vortex core magnetization is studied from magnetic force microscopy measurements. (author)

2001-09-23

305

Magnetic structure of Ce(Ru_0_._9_6Pd_0_._0_4)_2Si_2  

International Nuclear Information System (INIS)

The magnetic structure of a tetragonal Ce(Ru_0_._9_6Pd_0_._0_4)_2Si_2 single crystal, determined by neutron diffraction measurements, is similar to that observed in Rh doped alloys. The magnetic moments are oriented and modulated along the c-axis. Here the wave vector is incommensurate: k=(0,0,0.38). At 1.5 K, the moment is estimated to about 0.3 #mu#_B. Magnetization, magnetoresistance and Hall effect measurements performed on this alloy are also reported. (orig.).

306

MTF analysis of the near-real time neutron radiography facility at MURR  

International Nuclear Information System (INIS)

Several neutron radiography systems designed to view transient processes on a real-time basis have been developed. With the advent of these different real-time systems comes the necessity to develop a means to quantitatively evaluate and compare these systems. A suitable method for measuring the resolution capabilities of the image-forming system is the determination of the modulation transfer function (MTF). The MTF is a measure of an imaging system's ability to reproduce the spatial frequencies present in an image. The system in use at the University of Missouri Research Reactor is described. (Auth.).

1981-12-01

307

MCNP-DSP calculations of the {sup 252}Cf-source-driven noise analysis measurements of highly enriched uranium metal cylinders  

Energy Technology Data Exchange (ETDEWEB)

This paper presents calculations of the {sup 252}Cf-source-driven noise analysis measurements for subcritical highly enriched uranium metal cylinders using the Monte Carlo code MCNP-DSP. This code directly calculates the noise analysis data from the {sup 252}Cf- source-driven noise analysis method for both neutron and gamma ray detectors. Direct calculation of experimental observables by the Monte Carlo method allows for the benchmarking of the calculational model and the cross sections and for determining the bias in the calculation.

1995-07-01

308

Intergranular corrosion in Alloy 800: intercomparison between the Strauss test, the EPR method, and magnetic permeability measurements  

Energy Technology Data Exchange (ETDEWEB)

The susceptibility to intergranular corrosion of different heats of Alloy 800 was evaluated by three different methods: the ASTM A 262 Practice E (or modified Strauss test), the Electrochemical Potentiokinetic Reactivation method, and by magnetic-susceptibility measurements. Reasonably good agreement was found between the sensitization areas as defined by the three methods in the TTS diagrams. In some cases the area defined by the Strauss test was slightly smaller than that determined by the other two tests. The differences might be explained by the fact that the methods present different sensitivities to the chromium concentration at the grain boundaries. 27 references, 11 figures, 3 tables.

1982-01-01

309

Fission-track study of the uranium bio-geochemistry in carbonates of Bikini and Enewetak Atolls. Progress report, July 1, 1974--December 31, 1975  

International Nuclear Information System (INIS)

Major contributions during this contract period have been in developing an analytical procedure for Pu measurement, and in applying the developed procedures to determining the plutonium concentration and distribution in coral from the Bikini Atoll. In conjunction with these contributions, measurements using the fission-track method have been made of the uranium distribution and concentrations in several carbonate samples from drill cores obtained from the Runit Island Enewetak Atoll. Petrographic studies on these drill core samples have been made to correlate the uranium data with the mineralogical data.

310

Fission-track study of the uranium bio-geochemistry in carbonates of Bikini and Enewetak Atolls. Progress report, July 1, 1974--December 31, 1975  

Science.gov (United States)

Major contributions during this contract period have been in developing an analytical procedure for Pu measurement, and in applying the developed procedures to determining the plutonium concentration and distribution in coral from the Bikini Atoll. In conjunction with these contributions, measurements using the fission-track method have been made of the uranium distribution and concentrations in several carbonate samples from drill cores obtained from the Runit Island Enewetak Atoll. Petrographic studies on these drill core samples have been made to correlate the uranium data with the mineralogical data. (auth)

1975-09-01

311

Fission rate assessments in FFTF using passive techniques  

Energy Technology Data Exchange (ETDEWEB)

Fission rate assessments are being made in FFTF to provide input for determination of power distribution, peak power, total power, fuel burnup distribution, conversion ration and neutron spectral information by the multiple foil reaction rate method. A goal of the initial FFTF Characterization Program is to measure isotopic fission rates to an accuracy of 2 to 5% throughout FFTF by radiometric techniques. To achieve this goal, measurements were made in the FFTF In-Reactor Thimble to reduce the uncertainties of key parameters needed for radiometric fission rate mapping of the FFTF core.

1981-10-01

312

FFTF (Fast Flux Test Facility) Reactor Characterization Program: Absolute Fission-rate Measurements  

Energy Technology Data Exchange (ETDEWEB)

Absolute fission rate measurements using modified National Bureau of Standards fission chambers were performed in the Fast Flux Test Facility at two core locations for isotopic deposits of {sup 232}Th, {sup 233}U, {sup 235}U, {sup 238}U, {sup 237}Np, {sup 239}Pu, {sup 240}Pu, and {sup 241}Pu. Monitor chamber results at a third location were analyzed to support other experiments involving passive dosimeter fission rate determinations.

1981-05-01

313

FFTF (FAST FLUX TEST FACILITY) REACTOR CHARACTERIZATION PROGRAM ABSOLUTE FISSION RATE MEASUREMENTS  

Energy Technology Data Exchange (ETDEWEB)

Absolute fission rate measurements using modified National Bureau of Standards fission chambers were performed in the Fast Flux Test Facility at two core locations for isotopic deposits of {sup 232}Th, {sup 233}U, {sup 235}U, {sup 238}U, {sup 237}Np, {sup 239}Pu, {sup 240}Pu, and {sup 241}Pu. Monitor chamber results at a third location were analyzed to support other experiments involving passive dosimeter fission rate determinations.

1981-05-01

314

Electron microscopy and X-ray diffraction study of AlN layers  

International Nuclear Information System (INIS)

AlN nanocrystalline layers and superstructures are used in the modern optoelectronic technology as reflecting mirrors in semiconductor layers. In the present work the properties of AlN films prepared by sputtering methods from an AlN target in reactive Ar + N plasma were investigated. The characterization was performed with HRTEM, SEM, glancing angle XRD and RBS methods. The present measurements confirmed the polycrystalline structure of AlN layers and enabled the evaluation of their grain size. The roughness and thickness of the layers were additionally determined by ellipsometric and profilometric measurements. (author)

2001-09-23

315

Determination of charge carrier mobility in poly(3hexylthiophene) with different current transient measurement techniques  

Energy Technology Data Exchange (ETDEWEB)

The carrier mobility in organic disordered materials, such as conjugated polymers, plays an important role in understanding the behaviour of organic electronic devices. We investigated the mobility of charge carriers in poly(3-hexylthiophene) (P3HT) using different current transient measurement methods. Besides the conventional transient photoconductivity experiment, time-of-flight (TOF), we used extraction current transient techniques, such as charge carrier extraction by linearly increasing voltage (CELIV), probing equilibrium carriers instead. The field and temperature dependence of the mobility are discussed in view of hopping transport in a Gaussian density of states distribution.

2007-07-01

316

Atmospheric carboxylic acids in southern California  

Energy Technology Data Exchange (ETDEWEB)

Intensive measurements of organic acids, inorganic acids, aldehydes and peroxyacetyl nitrate (PAN) in urban air were carried out at a Southern California smog receptor site, Glendora, CA, August 12-22, 1986. The objective of this project was to augment the data base regarding organic acids in urban air and to assess their role with emphasis on ambient levels, diurnal variations, phase distribution, emissions, in-situ formation and removal. The relative abundance of organic acids and inorganic acids was determined for the first time from simultaneous measurements carried out during this study.

1988-09-01

317

Application of a 3-beam #gamma# densitometer to two-phase flow regime and density measurements  

International Nuclear Information System (INIS)

A method of using gamma radiation to determine the density and phase distribution in two-phase flows in pipes is described. Three collimated beams of radiation that pass through a pipe cross-section at different radial positions are used. A theory and computer program used to relate the measured attenuation of these beams to a three-parameter model of the phase distribution and to the average density and void fraction are discussed. Data obtained during both static and dynamic verification experiments using Lucite inserts are presented, as well as the results of several tests done in high pressure, steam-water flows.

1976-08-11

318

Achievements in testing of the MGA and FRAM isotopic software codes under the DOE/NNSA-IRSN cooperation of gamma-ray isotopic measurement systems  

Energy Technology Data Exchange (ETDEWEB)

DOE/NNSA and IRSN collaborated on a study of gamma-ray instruments and analysis methods used to perform isotopic measurements of special nuclear materials. The two agencies agreed to collaborate on the project in response to inconsistencies that were found in the various versions of software and hardware used to determine the isotopic abundances of uranium and plutonium. IRSN used software developed internally to test the MGA and FRAM isotopic analysis codes for criteria used to stop data acquisition. The stop-criterion test revealed several unusual behaviors in both the MGA and FRAM software codes.

2009-01-01

319

A study on the anodic protection of titanium evaporators in Al[sub 2](SO[sub 4])[sub 3] solution  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of the anodic protection of titanium evaporators in Al[sub 2](SO[sub 4])[sub 3] solution was studied by the measurement of polarization curves, weight loss, solubility of passive film and AC impedance. The protection parameters and efficiency were determined. In addition, the practical technology of anodic protection was studied by screening reference electrodes and auxiliary cathodes. Throwing power was also measured. Four rows of tube-type evaporators of titanium have been anodically protected in situ. Field tests lasting more than one year shows satisfactory results. (orig.)

1993-07-01

320

A high-sensitivity scintillation chamber for radon in gas  

Energy Technology Data Exchange (ETDEWEB)

A large scintillation chamber of 6.7 l volume for direct radon concentration measurements in gas is presented. With two 5 in. photomultipliers on opposite sides, working in coincidence, a concentration as low as about 0.5 mBq/l is detectable with 10% standard deviation after 1000 min measuring time. With the achieved background count rate of 0.42 counts/min and the counting efficiency of 0.607 for [sup 222]Rn and its progenies the absolute minimal detectable specific activity is reached with 0.17 mBq/l at about 12 000 min. The method to determine this minimum detectable activity is outlined. ((orig.))

1994-06-15

321

Measurement of the mean energy of the off-axis incident electron without the beam guide. Using a scintillating fiber beam-energy monitor for electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

In the case of total skin electron therapy without the beam guide, the electron beam is scattered just outside the gantry exit, dose uniformity in the field is broken, and dose is spread outside the light field. The aims of this study were to measure the mean energy of the off-axis incident electron beam without the beam guide and to establish a reference for the clinical situation. For the measurement, a 4 MeV electron beam was selected among several energies from the linear accelerator. A scintillating fiber beam energy monitor measured the mean energy of the incident electron beam. This energy monitor is a small, light-weight piece of equipment composed of a wedge absorber, scintillation fiber, and photodiode. We found the relationship between electron energy and the indicated value of the energy monitor by means of the estimation of correction factors for five different kinds of electron energy. The preferable linear ...

2002-06-01

322

Cf-source-driven neutron-noise measurements of subcriticality for a 4. 95 wt% /sup 235/U-enriched uranyl fluoride solution cylinder  

Energy Technology Data Exchange (ETDEWEB)

A method for determining the reactivity of subcritical systems of fissile material, using neutron-noise power spectral density measurements in conjunction with a /sup 252/Cf source, has been tested in experiments with an aqueous solution containing uranium fluoride (4.95 wt% /sup 235/U). The kappasub(eff)-values obtained from the ratio of spectral densities G*/sub 12/G/sub 13//G/sub 11/G/sub 23/ agreed with those from break-frequency noise analysis and with bias-corrected transport theory calculations within the statistical uncertainty of the measurements. Corrections for the effects of spatial modes and source-detector locations appear to be well-understood, since measurements for a variety of source-detector positions resulted in essentially the same kappasub(eff)-values. Modal correction factors were such that ignoring them would result in higher values of kappasub(eff) than actually occur. The ...

1986-01-01

323

Beta and gamma decay heat measurements between 0.1s - 50,000s for neturon fission of {sup 235}U, {sup 238}U and {sup 239}Pu. Progress report, June 1, 1992--December 31, 1994  

Energy Technology Data Exchange (ETDEWEB)

In the investigations reported here, a helium-jet/tape-transport system was used for the rapid transfer of fission products to a low-background environment where their aggregate beta and gamma-ray spectra were measured as a function of delay time after neutron induced fission of {sup 235}U, {sup 238}U and {sup 239}Pu. Beta and gamma-ray energy distributions have been deduced for delay times as short as 0.2 s and extending out to 100,000s. Instrumentation development during the initial phase of the project included: (1) assembly and characterization of a NaI(Tl) spectrometer for determining aggregate gamma-ray energy distributions, (2) development and characterization of a beta spectrometer (having excellent gamma-ray rejection) for measuring aggregate beta-particle energy distributions, (3) assembly and characterization of a Compton-suppressed HPGe spectrometer for determining gamma-ray intensities of ...

1997-05-01

324

Experimental investigation of dose calibrator response for "1"2"5I brachytherapy solutions contained in 5 mL plastic syringes and 2 mL conical glass v-vials as a function of filling mass  

International Nuclear Information System (INIS)

The effect of measurement geometry on the determination of the activity of solutions containing "1"2"5I for use in brachytherapy applications has been investigated for 5 mL plastic syringes and 2 mL conical glass dose vials as a function of filling mass. New dial settings for the syringes over a filling mass range of 1 to 3 g have been determined to be 497#+-#8 and 469#+-#8 (expanded, k=2, uncertainties) for the NIST Capintec CRC-12 and Capintec CRC-35R, respectively, with any effect due to the filling mass lying within the uncertainty in the activity calibration. A filling mass effect was observed in the dose vials, causing a 10.5% reduction in the chamber response from a 2 g filling mass to 1 g. Dial settings at 2 g were experimentally found to be 143#+-#2 and 135#+-#2 (expanded uncertainties) for the NIST Capintec CRC-12 and Capintec CRC-35R, respectively. The appropriate dial settings for the same vials with a 1 g ...

2002-07-01

325

The in vivo measurement of radiocaesium activity in broiler chickens  

Energy Technology Data Exchange (ETDEWEB)

Contamination of certain areas of Europe with radiocaesium from the Chernobyl accident led to a higher {sup 137}Cs accumulation (i.e. 300-600 Bq kg{sup -1}) in grain and to potential post-accident contamination of broiler chickens. In future, such contamination may require a simple determination of the {sup 137}Cs activity concentration in broiler chicken meat which would lead to measures for preventing the recommended limits of radionuclide contamination of the meat for human consumption from being exceeded. This paper describes the development of a rapid method for the in vivo monitoring of the broiler chicken using a lead-shielded sodium iodide detector. The method enables simply fixed live chicken to be monitored, the results showing a good correlation (R{sup 2}=0.98) with measurements of meat from chicken previously monitored in vivo prior to slaughter.

2000-05-01

326

Testing measurements at horizontal channels of the MARIA reactor performed using neutron spectrometers; Pomiary testowe przy kanalach poziomych reaktora MARIA wykonane przy uzyciu spektrometrow neutronow  

Energy Technology Data Exchange (ETDEWEB)

By means of neutron diffraction, using the standard polycrystalline sample of Al{sub 2}O{sub 3}, measurements on three (of four spectrometers) already installed in the front of horizontal channels of MARIA reactor have been performed. Basing on these experiments as well as on activation measurements carried out earlier, the fluxes of monoenergetic neutrons have been estimated. These experiments allowed to determine (for a given geometry and kind of monochromators chosen) the resolution efficiency of instruments and high order contamination in the reflected beam. With the help of polycrystalline vanadium and TbBr{sub 3} sample, the possibility of studies using the inelastic scattering process have been tested. (author) 7 refs, 15 figs, 7 tabs

1997-12-31

327

Temperature measurement of 6He?+? ions confined in a transparent Paul trap  

British Library Electronic Table of Contents (United Kingdom)

The LPCTrap setup is a transparent Paul trap dedicated to the measurement of the ??? correlation coefficient a ?? in the ? decay of trapped radioactive nuclides. In a first experiment, the system has been used to record ?105 coincidences between the ? particles and recoiling ions emitted from the decay of 6He?+? ions. The analysis of the collected data has already shown that the size of the 6He?+? ion cloud confined in the Paul trap is a critical parameter, potentially limiting the accuracy on the a ?? measurement. We report here the precise determination of the trapped ion cloud temperature and size. This was performed by extracting the trapped ions toward a position sensitive micro channel plate detector at different phases of the RF driving field. We find a temperature T exp ?= 0.107(7)...

2011-01-01

328

Serum gamma-glutamyltransferase is associated with arterial stiffness in healthy individuals  

British Library Electronic Table of Contents (United Kingdom)

Summary Objective- Gamma-glutamyltransferase (GGT) has been reported to be useful in predicting cardiovascular disease. Arterial stiffness measured by brachial-ankle pulse wave velocity (baPWV) is not only a marker of vascular damage but a significant predictor of cardiovascular events. Gender difference has been reported in the association between GGT and baPWV. We assessed, therefore, the association between GGT and baPWV in a large population and determined whether there was gender difference. Design- This cross-sectional study was conducted at the Asan Medical Centre, Seoul, Republic of Korea. Subjects and measurements- Serum GGT, baPWV and conventional risk factors were measured in 10 988 apparently healthy subjects (7248 men, 3740 women) who participated in a routine health screening...

2011-01-01

329

Result analysis on the parameter test of radium specific activity calculation in the tailing of uranium mine No. 794  

International Nuclear Information System (INIS)

This paper first introduces the calculating method of radium specific activity to determine the radon emanation rate of tailing of uranium mine No. 794, the method needs two parameters: radon emanation coefficient and radon diffusion coefficient. According to the measured results of parameters and the contrast between radium specific activity of indoor chemical analysis of field sample and field gamma-ray spectra, the authors discuss the variation rules and characteristics of radon emanation coefficient and radon diffusion coefficient, and the best climate and seasons for measuring these parameters in northern China, and finally summarize the characteristics of this method through analyzing measured results. (authors)

2006-09-01

330

Rapid and precise measurement of flatband voltage  

Science.gov (United States)

The paper outlines the design, principles of operation, and calibration of a five-IC network intended to give a rapid, precise, and automatic determination of the flatband voltage of MOS capacitors. The basic principle of measurement is to compare the analog output voltage of a capacitance meter - which is directly proportional to the capacitance being measured - with a preset or dialed-in voltage proportional to the calculated flatband capacitance by means of a comparator circuit. The bias to the MOS capacitor supplied through the capacitance meter is provided by a ramp voltage going from a negative toward a positive voltage level and vice versa. The network employs two monostable multivibrators for reading and recording the flatband voltage and for resetting the initial conditions and restarting the ramp. The flatband voltage can be held and read on a digital voltmeter.

1976-05-01

331

Process of preparing metal parts to be heated by means of infrared radiance  

Energy Technology Data Exchange (ETDEWEB)

A method for preparing metal for heating by infrared radiance to enable uniform and consistent heating. The surface of one or more metal parts, such as aluminum or aluminum alloy parts, is treated to alter the surface finish to affect the reflectivity of the surface. The surface reflectivity is evaluated, such as by taking measurements at one or more points on the surface, to determine if a desired reflectivity has been achieved. The treating and measuring are performed until the measuring indicates that the desired reflectivity has been achieved. Once the treating has altered the surface finish to achieve the desired reflectivity, the metal part may then be exposed to infrared radiance to heat the metal part to a desired temperature, and that heating will be substantially consistent throughout by virtue of the desired reflectivity.

2009-06-09

332

Photocurrent and capacitance investigations into the nature of the passive films on austenitic stainless steels  

Energy Technology Data Exchange (ETDEWEB)

Photocurrent and capacitance measurements of semiconductor passive films formed on metals and alloys can be used to study the electronic properties and reveal indirect information about structure and composition. The current work used these techniques to investigate the electronic properties of the passive films formed on three austenitic stainless steels, types 304L, 316L and 254SMO, in borate. Evidence was found for the existence of a large number of localised mid bandgap states, consistent with amorphous oxides. However, the flat-band potentials of the austenitic stainless steel passive films were found to be independent of both composition and measuring frequency. The most credible explanation for the bandgap values determined from photocurrent measurements is that the passive films are formed as dual layers, iron oxide outer layer and chromium oxide inner layer. This model does not need to evoke ...

2008-01-15

333

Photocurrent and capacitance investigations into the nature of the passive films on austenitic stainless steels  

International Nuclear Information System (INIS)

Photocurrent and capacitance measurements of semiconductor passive films formed on metals and alloys can be used to study the electronic properties and reveal indirect information about structure and composition. The current work used these techniques to investigate the electronic properties of the passive films formed on three austenitic stainless steels, types 304L, 316L and 254SMO, in borate. Evidence was found for the existence of a large number of localised mid bandgap states, consistent with amorphous oxides. However, the flat-band potentials of the austenitic stainless steel passive films were found to be independent of both composition and measuring frequency. The most credible explanation for the bandgap values determined from photocurrent measurements is that the passive films are formed as dual layers, iron oxide outer layer and chromium oxide inner layer. This model does not need to evoke ...

2008-01-01

334

PVT-apparatus for measurements on gas/oil solutions up to 2000 bar and 440 K  

Energy Technology Data Exchange (ETDEWEB)

A high pressure piezometer is described with which pVT-measurements on solutions of gases in liquids like oils can be performed at pressures and temperatures up to 2000 bar and 440 K, respectively. The present investigations deal mainly with the system squalaneCO/sub 2/ at different mole fractions, but also with squalaneN/sub 2/. The high accuracy of the measurements reveals a pronounced structure of the pV-curves in dependence on temperature and mole fraction. At larger mole fractions is the unequivocal assignment of the phases ambiguous, and the representation of the experimental data in terms of an equation of state not possible for the whole pressure and temperature range. However, for solutions with lower mole fractions could be determined the saturation pressures and the isothermal compressibility in the unsaturated region. Furthermore, the molar excess volumes of the mixture have been calculated and the phase ...

1982-11-01

335

New neutron capture and total cross section measurements on {sup 88}Sr and their impact on s-process nucleosynthesis  

Energy Technology Data Exchange (ETDEWEB)

The authors have made new and improved measurements of the neutron capture and total cross sections of {sup 88}Sr at the Oak Ridge Electron Linear Accelerator (ORELA). Improvements over previous measurements include a wider incident neutron energy range, the use of metallic rather than carbonate samples, better background subtraction, reduced sensitivity to sample-dependent backgrounds, and better pulse-height weighting functions. Because of its small cross section, the {sup 88}Sr(n,{gamma}) reaction is an important bottleneck during the s-process nucleosynthesis. Hence, an accurate determination of this rate is needed to better constrain the neutron exposure in s-process models and to more fully exploit the recently discovered isotopic anomalies in certain meteorites. They describe the experimental procedures, compare the results to previous data, and discuss their astrophysical impact.

1998-11-01

336

Multiple ordered phases in the filled skutterudite compound PrOs4As12  

Energy Technology Data Exchange (ETDEWEB)

Magnetization, specific heat, and electrical resistivity measurements were made on single crystals of the filled skutterudite compound PrOs{sub 4}As{sub 12}. Specific heat measurements indicate an electronic specific heat coefficient {gamma} {approx} 50-200 mJ/mol K{sup 2} at temperatures 10 K {le} T {le} 18 K, and {approx} 1 J/mol K{sup 2} for t {le} 1.6 K. Magnetization, specific heat, and electrical resistivity measurements reveal the presence of two, or possibly three, ordered phases at temperatures below {approx} 2.3 K and in fields below {approx} 3 T. The low temperature phase displays antiferromagnetic characteristics, while the nature of the ordering in the other phase(s) has yet to be determined.

2006-03-20

337

Magnetically applied pressure-shear : a new technique for direct strength measurement at high pressure (final report for LDRD project 117856).  

Energy Technology Data Exchange (ETDEWEB)

A new experimental technique to measure material shear strength at high pressures has been developed for use on magneto-hydrodynamic (MHD) drive pulsed power platforms. By applying an external static magnetic field to the sample region, the MHD drive directly induces a shear stress wave in addition to the usual longitudinal stress wave. Strength is probed by passing this shear wave through a sample material where the transmissible shear stress is limited to the sample strength. The magnitude of the transmitted shear wave is measured via a transverse VISAR system from which the sample strength is determined.

2010-09-01

338

First measurement of ADS parameters using B- -> D0K- decays in hadron collisions  

CERN Document Server

Measurements of branching fractions and CP-asymmetries of B^{-} \\rightarrow D^{0}K^{-} modes allow a theoretically-clean extraction of the CKM angle \\gamma. The method proposed by Atwood, Dunietz and Soni (ADS) makes use of a decay chain where color and Cabibbo suppression interfere, which produces large CP-violating asymmetries. The CDF experiment reports the first measurement at a hadron collider of branching fractions and CP-asymmetries of suppressed B^{-} \\rightarrow D^{0}h^{-} signals, where h is \\pi or K. Using 5.0 fb^{-1} of data we found a combined significance exceeding 5\\sigma and we determined the ADS parameters with accuracy comparable with B-factories.

2011-01-01

339

Fault location observability analysis and optimal meter placement based on voltage measurements  

British Library Electronic Table of Contents (United Kingdom)

Various transmission line fault location algorithms have been proposed in the past depending on measurements available. These methods evince that if a sufficient number of meters are placed in a power network to record the fault measurements, then the fault location can be reliably estimated. A relevant question to ask may be: how many meters are sufficient in order to derive a reliable and unique fault location estimate for a given network? This paper addresses this question by defining and performing the fault location observability analysis. An optimal meter placement scheme is proposed for determining the optimal locations to place meters so as to make the system observable while minimizing the required number of meters to reduce costs. The proposed method is especially useful for powe...

2009-01-01

340

Dynamic and static error analyses of neutron radiography testing  

Energy Technology Data Exchange (ETDEWEB)

Neutron radiography systems are being used for real-time visualization of the dynamic behavior as well as time-averaged measurements of spatial vapor fraction distributions for two phase fluids. The data in the form of video images are typically recorded on videotape at 30 frames per second. Image analysis of he video pictures is used to extract time-dependent or time-averaged data. The determination of the average vapor fraction requires averaging of the logarithm of time-dependent intensity measurements of the neutron beam (gray scale distribution of the image) that passes through the fluid. This could be significantly different than averaging the intensity of the transmitted beam and then taking the logarithm of that term. This difference is termed the dynamic error (error in the time-averaged vapor fractions due to the inherent time-dependence of the measured data) and is separate from the static ...

1999-03-01

341

Development of a radon standard source  

Energy Technology Data Exchange (ETDEWEB)

The present paper describes the development of a radon standard source for use in establishing the traceability of radon concentration measurements in air. Previously, radon generated by bubbling air through a radium salt solution was widely used for calibration of radon measurement equipment; however, the handling of a solid-phase radon source is easier. In the present study, the radioactivity of radon released in a vapor phase was determined from the difference between the radioactivity of the radium and the residual radon progenies in the source. A germanium detector, calibrated using gamma reference sources, was used for these radioactivity measurements. Under equilibrium conditions the radioactivity of the radon released from the radium source was found to be 988 Bq. The source was sealed in a stainless-steel container having a nominal capacity of 6 l to produce a radon standard source of density ...

2005-06-11

342

Cobalt release from PCA steel during possible fusion reactor accidents  

Energy Technology Data Exchange (ETDEWEB)

Possible accident scenarios for a fusion reactor include breaches in the vacuum or cooling system. Intruding air or steam could react with structural or plasma facing materials, possibly mobilizing radioactive isotopes. Safety assessments must consider the early dose at the site boundary from the release of these activated materials. Previous calculations have indicated that cobalt isotopes dominate dose calculations for designs using stainless steel. Values used in these calculations, however, had been largely determined by the measurement limits of the chemical analysis methodology instead of measured releases. The purpose of the current study was to refine the analytical method to reduce the limit for detecting cobalt, and then test PCA steel in air and steam between 973 and 1473 K. Goals were to obtain more accurate measurements of cobalt mobilization in terms of g/m{sup 2}{center_dot}h and insight ...

1995-01-01

343

Characteristics of infrared-stimulated luminescence from a feldspar at low temperatures  

International Nuclear Information System (INIS)

The characteristics of infrared-stimulated luminescence (IRSL) from a sample of potassium feldspar at low temperatures are presented. These studies extend the previous work from this laboratory on the optical bleaching characteristics and emission spectra of feldspars at room temperature and recent measurements of the stimulated spectrum for a sample of potassium feldspar at room temperature. Stimulation spectra have been measured at 290, 160 and 145 K. By fitting Gaussian functions to the spectra, the peak position is shown to shift to higher photon energies at lower temperatures and the full-width half-maximum of the peak to reduce with decreasing temperature. The variation of IRSL intensity with temperature for several stimulating wavelengths has been determined and the form of the IRSL decay curve measured at 290 and 160 K. No substantial differences were observed in the form of the decay curves at ...

1993-07-01

344

Calibration of solid state nuclear track detector CR-39 for radon measurements  

Energy Technology Data Exchange (ETDEWEB)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

2007-07-01

345

Calibration of solid state nuclear track detector CR-39 for radon measurements  

International Nuclear Information System (INIS)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

346

Bragg Curve Spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

An alternative utilization is presented for the gaseous ionization chamber in the detection of energetic heavy ions, which is called Bragg Curve Spectroscopy (BCS). Conceptually, BCS involves using the maximum data available from the Bragg curve of the stopping heavy ion (HI) for purposes of identifying the particle and measuring its energy. A detector has been designed that measures the Bragg curve with high precision. From the Bragg curve the range from the length of the track, the total energy from the integral of the specific ionization over the track, the dE/dx from the specific ionization at the beginning of the track, and the Bragg peak from the maximum of the specific ionization of the HI are determined. This last signal measures the atomic number, Z, of the HI unambiguously.

1981-05-01

347

A measurement of the parity-violating gamma-ray asymmetry in the neutron-proton capture  

Energy Technology Data Exchange (ETDEWEB)

The {rvec n} + p {yields} d + {gamma} experiment under construction at LANSCE studies the weak interaction between neutrons and protons. The experiments will measure the directional dependence of the parity-violating {gamma}-ray asymmetry, A{sub {gamma}}, in the polarized cold neutron capture by para-hydrogen. The goal is to measure A{sub {gamma}} with uncertainty of 0.5 x 10{sup -8}, 10% of its predicted value. A{sub {gamma}} primarily isolates the {Delta}I = 1 component of the hadronic weak interaction and thus will determine the long-range weak pion-nucleon coupling constant H{sub {pi}}{sup 1}. The experiment is carefully designed for the LANSCE pulsed spallation neutron source to achieve the proposed statistical precision and to control systematic errors. We discuss the experiment and its status.

2002-01-01

348

Two-phase fluid flow measurements in small diameter channels using real-time neutron radiography  

International Nuclear Information System (INIS)

A series of real-time, neutron radiography, experiments are ongoing at the Texas A and M Nuclear Science Center Reactor (NSCR). These tests determine the resolving capabilities for radiographic imaging of two phase water and air flow regimes through small diameter flow channels. Though both film and video radiographic imaging is available, the real-time video imaging was selected to capture the dynamic flow patterns with results that continue to improve. (author)

1994-04-05

349

The analysis of coupled heat and particle transport in Tokamaks by means of Fourier transform  

Energy Technology Data Exchange (ETDEWEB)

A method to deduce the 2 x 2 transport matrix for coupled heat and particle transport in Tokamaks is proposed. The method applies to perturbative experiments, and is based on a Fourier transform of the measured signals of temperature and density. By analyzing different linear combinations of temperature and density, the eigenvectors and eigenvalues of the transport matrix are determined. The method is tested for a number of illustrative cases using simulated data, and the sensitivity to noise on the signals is evaluated. (author).

1992-04-01

350

Tests for mutagencity of free radicals formed in irradiated sugars and amino acids  

International Nuclear Information System (INIS)

Radicals formed in gamma-irradiated crystals of galactose and glycine were found, upon dissolution, to cause mutagenesis of Salmonella typhimurium strains TA-98 and TA-100. Although the reproducibility of the results has not been adequately determined, they suggest the possibility of developing a test to measure the mutagenic-carcinogenic potential of radiation-induced free radicals with a microbial system.

1977-05-01

351

Steam generator tube denting-criteria for tube plugging  

International Nuclear Information System (INIS)

When steam generator tube denting was identified, steps were taken to retard the rate of corrosion and to develop corrective measures if possible. Techniques were developed to determine the exact shapes of the tubes, and procedures were devised to analyze resulting strain and operating stresses. Tube plugging criteria were established, and in twelve years of operation, there has been only one instance of a forced outage due to a tube leak.

352

Spot size and Guoy phase invariant telescope for auto-alignment of resonant cavities  

International Nuclear Information System (INIS)

We present both the theory and an experimental method to accurately set up a Guoy phase telescope, where both the output spot size and orthogonality condition are invariant to distance from the cavity beam waist. We demonstrate that Gaussian spot size measurements can be used as a diagnostic to determine the desired locations of split area photodetectors. The Guoy phase invariance is verified using the tilt-locking technique.

2004-03-07

353

Report on the special program 78 satellite geodesy of the technical university of Munich  

Energy Technology Data Exchange (ETDEWEB)

Various topics include: (1) direction finding, (2) range finding, (3) Doppler measurements, (4) construction of a receiver for radio interferometry, (5) mobile laser range finding system, (6) figure-and field parameter determination/geopotential, (7) dynamics of the Earth-Moon system, and (8) kinematics of geodetic point fields.

1981-01-01

354

Real time neutron diffraction experiments using Bragg edges  

Energy Technology Data Exchange (ETDEWEB)

Time resolved phase transition and strain experiments have been performed on the millisecond time scale using a Bragg-edge transmission technique that has been developed at the Los Alamos National Laboratory. The precision with which lattice parameters can be determined from edge positions is sufficient to perform high-resolution strain measurements in uniaxial stress.

1995-12-31

355

Real time neutron diffraction experiments using Bragg edges  

International Nuclear Information System (INIS)

Time resolved phase transition and strain experiments have been performed on the millisecond time scale using a Bragg-edge transmission technique that has been developed at the Los Alamos National Laboratory. The precision with which lattice parameters can be determined from edge positions is sufficient to perform high-resolution strain measurements in uniaxial stress.

1994-12-02

356

Real time control of micro-machine system using micro-computer based fuzzy logic power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

A micro-computer based fuzzy logic power system stabilizer is applied to a micro-machine system to investigate its efficiency in real time control. The stabilizing signal is determined by using measured speed or real power signals at every sampling time to damp the system oscillations. The results show the proposed stabilizer improves the system damping effectively subject to various types of disturbances.

1994-12-01

357

Radiation doses and somatic risk to patients during cardiac radiological procedures  

International Nuclear Information System (INIS)

The radiation dose to a series of adult and paediatric patients undergoing cardiac catheterisations and adults having percutaneous transluminal coronary angioplasty has been measured/determined directly using lithium fluoride thermoluminescent dosemeters and indirectly using an air ionisation chamber which indicated exposure-area product. Somatic and genetic risks are estimated from the dosimetry results. It is suggested that the magnitude of the radiation hazard is negligible compared with other clinical hazards associated with these procedures. (author).

1986-01-01

358

Radial distribution of bonded fission gas in mixed carbide fuel pins  

International Nuclear Information System (INIS)

The fission gas xenon bonded in bubbles, in pore, and in the lattice of mixed carbide fuels is measured by electron-probe microanalysis. Radial xenon distribution and release curves are determined and are calibrated by gas chromatography of the bonded fission gas and by burnup analysis in the respective pin sections of the irradiation experiments FR2 6A and 6C, Mol 11/K 2, and DFR 330/1. The results are correlated to the microstructure of the fuel, bonding medium, temperature, and burnup. (Auth.).

1979-01-01

359

Pyrheliometry  

Energy Technology Data Exchange (ETDEWEB)

Pyrheliometric methods are described (particularly methods for measuring the solar constant), and theoretical and experimental studies in this field are surveyed and systematized. Particular attention is given to the analysis of instruments intended for pyrheliometers used as standards, reference instruments, and solar-constant meters is examined, and consideration is given to methods for determining the thermal-radiation properties of absorbing coatings and methods for calculating the absorption coefficients of cavity receivers.

1981-01-01

360

Photoexcitation and optical pumping in a barium atomic beam  

International Nuclear Information System (INIS)

An apparatus allowing the photoexcitation of barium atomic beam over its whole surface is described. This photoexcitation is achieved by another barium spectrum emitted up steam of the beam by a cathodic out-flow produced at the exit oven. The fluorescence spectrum is studied in detail as well as the influence of different parameters, such as oven temperature, current intensity of the outflow, and excitation depth. A calculation shows how to determine Einstein coefficient, oscillator strengths and atomic lifetimes from our experimental measurements.

361

Optimal Quantum State Estimation by No-Signaling Principle  

CERN Document Server

We obtain a simple derivation of the optimal quantum state estimation of a two-level system using the no-signaling principle. In particular, we show that the no-signaling principle determines the unique form of the guessing probability, independently to a given figure of merit such as the fidelity or the information gain. This proves that optimal measurements for a two-level quantum system is the same for almost all figures of merit.

2010-01-01

362

Measuring and Explaining Electricity Price Changes in Restructured States  

Energy Technology Data Exchange (ETDEWEB)

An effort to determine the effect of restructuring on prices finds that, on average, prices for industrial customers in restructured states were lower, relative to predicted prices, than prices for industrial customers in non-restructured states. This preliminary analysis also finds that these price changes are explained primarily by high pre-restructuring prices, not whether or not a state restructured. (author)

2006-06-15

363

Measurement and apportionment of radon source terms for modeling indoor environments  

Energy Technology Data Exchange (ETDEWEB)

This research has two main goals; (1) to quantify mechanisms for radon entry into homes of different types and to determine the fraction of indoor radon attributable to each source and (2) to model and calculate the dose (and therefore alpha particle fluence) to cells in the human and animal tracheobronchial tree that is pertinent to induction of bronchogenic carcinoma from inhaled radon daughters.

1990-01-01

364

Mass-energy spectra of fission fragments in the reaction {sup 242m}Am(n{sub th},f)  

Energy Technology Data Exchange (ETDEWEB)

The mass-energy spectra of the fragments of thermal fission of {sup 242m}Am are measured using the time-of-flight technique. The resulting mass-yield curve and peak-to-valley ratio agree with radiochemical data. The parameters of the kinetic energy distribution of the fragments are determined for the first time. Data on the fine structure of mass spectra in the region of cold fragmentation are presented. 15 refs., 4 figs.

1994-12-01

365

Magnetic diagnostic of beta poloidal and internal inductance of plasma in the TCA/BR tokamak  

Energy Technology Data Exchange (ETDEWEB)

This report continues the studies of simplified methods, of magnetic diagnostics in application to TCA/BR tokamak. Here we study the accuracy of known formula for {beta}{sub 1} + l{sub 1}/2 determination from the poloidal magnetic field asymmetry. Errors of the diamagnetic measurements due to vibrations of the vacuum vessel are also considered. (author). 3 refs., 1 fig., 1 tab.

1996-12-31

366

Local aspects of superselection rules. Pt. 2  

Energy Technology Data Exchange (ETDEWEB)

In a theory where the local observables are determined by local field algebras as the fixed points under a (a priori noncommutative) group of gauge transformations of the first kind, we show that, if the field algebras possess intermediate type I factors, we can construct observables having the meaning of local charge measurements, and local current algebras in the field algebras.

1983-03-01

367

Laser-induced fluorescence measurement of sup(6,7)lithium isotope shift  

Energy Technology Data Exchange (ETDEWEB)

Values of frequency splittings in the lithium isotopes have been determined with the aid of laser-induced fluorescene in a supersonic beam, perpendicularly irradiated by a CW ring dye laser. The residual 2s-2p isotope shift has been found to bw 4721.8 +- 2.0 MHz, leading to a specific mass shift for the 2p level of -3610.8 +- 5 MHz.

1986-07-01

368

In-plane resolved in-situ measurements of the membrane resistance in PEFCs  

Energy Technology Data Exchange (ETDEWEB)

The conductivity of the membrane is a limiting factor for the efficiency and power density of PEFCs. Because this conductivity is strongly dependent on the membrane hydration, water management is an important aspect of PEFC optimisation. Single cell model experiments were made in order to determine the in-plane hydration of a Nafion{sup R} membrane under fuel cell conditions as function of the gas humidities. (author) 4 fig., 3 refs.

1999-08-01

369

Impact of the ENDF/B-VI Cross Section on the RPV Fluence Determination  

Energy Technology Data Exchange (ETDEWEB)

The calculations with the broad-group cross-section library Bugle-96, and atom displacement (dpa) cross sections for iron, both derived from ENDF/B-VI data, result in higher calculated fast neutron fluxes, better agreement of calculations with radiometric dosimeter measurements, and significantly slower dpa rate attenuation through pressure vessel walls relative to the results with their predecessors: the Sailor library and ASTM iron dpa cross sections.

1999-09-12

370

High power model fabrication of disk-and -washer cavity  

International Nuclear Information System (INIS)

The high-power model of Disk-and Washer (DAW) cavity for electron acceleration is under fabrication. Basic Dimensions of the cavity were determined from aluminum model measurement and electromagnetic field calculation. We have fabricated model made of OFC (Oxygen Free Copper) five times in total. Some details are optimized and corrected, and then the final brazing are proceeding. These model results and present status are described. (author)

2000-07-12

371

Heat treatment effect on impact strength of 40Kh steel  

Energy Technology Data Exchange (ETDEWEB)

The paper presents results of studies on the effect of heat treatment on strength and pattern of 40Kh steel impact failure. Loading levels corresponding to macroscopic spalling microdamage initiation in the material are determined for three initial states. Metallographic study on the spalling failure pattern for 40Kh steel in different initial states and data on microhardness measurement are presented.

1984-01-01

372

Finding the best quadratic approximation of a function  

British Library Electronic Table of Contents (United Kingdom)

This article examines the question of finding the best quadratic function to approximate a given function on an interval. The prototypical function considered is f(x) = ex. Two approaches are considered, one based on Taylor polynomial approximations at various points in the interval under consideration, the other based on the fact that three non-collinear points determine a unique quadratic function. Three different techniques for measuring the error in the approximations are considered.

2011-01-01

373

Final Report: Planetary Instrument Definition and Design Program (PIDDP) Support Project  

Energy Technology Data Exchange (ETDEWEB)

The results of Sandia National Laboratories' participation in the NASA Planetary Definition and Design Program are summarized. Areas reported include the characterization of large area cadmium zinc telluride spectrometers and the application of simulation techniques to the prediction of device performance. Also investigated was the response of mercuric iodide devices in the region from 1 to 100 KeV. A literature study to determine the status or radiation damage measurements in room temperature semiconductor devices is also reported.

1999-03-01

374

Excess transit time as a function of burst current in an exploding bridgewire detonator  

Energy Technology Data Exchange (ETDEWEB)

Transit time, the time from bridgewire burst until breakout of detonation from the output pellet of an exploding bridgewire detonator, was measured as a function of burst current. From this data, in conjunction with known equations for run distance versus pressure, unreacted explosive Hugoniots, and detonation properties of the initial pressing pellet, the run distance in the initial pressing explosive pellet and shock pressure from the exploding bridgewire were determined, both as a function of burst current.

1990-01-01

375

Examination of compression and resilience characteristics of fibrous insulation blankets  

International Nuclear Information System (INIS)

Load-deflection characteristics of alumina and alumino-silicate fibrous blankets were experimentally determined. Load retention and springback capability of combinations of these materials were measured in a 10,000-hour test at surface temperatures of 650 to 1000"0C (1200 to 1832"0F). Experimental results are presented and future testing plans are discussed.

376

Electrical Circuit Tester  

Energy Technology Data Exchange (ETDEWEB)

An electrical circuit testing device is provided, comprising a case, a digital voltage level testing circuit with a display means, a switch to initiate measurement using the device, a non-shorting switching means for selecting pre-determined electrical wiring configurations to be tested in an outlet, a terminal block, a five-pole electrical plug mounted on the case surface and a set of adapters that can be used for various multiple-pronged electrical outlet configurations for voltages from 100 600 VAC from 50 100 Hz.

2006-04-18

377

Effects of electromagnetic pollution on human health discussed  

Energy Technology Data Exchange (ETDEWEB)

The harmful effects of high-intensity electric fields on human beings are discussed. Formulas for determining the field strength of high voltage transmission lines and track lines and experimental data of these effects on mice are given. Protective measures from these hazards are introduced. 18 references, 7 figures, 5 tables.

1982-01-01

378

Effect of aging on the pitting corrosion behavior in Al-Li alloys  

Energy Technology Data Exchange (ETDEWEB)

In the present work, electrochemical measurements and corrosion tests in NaCl solutions were carried out to study the effect of aging treatments on pitting corrosion behavior in a 8090 alloy and its high purity Al-Li binary alloy analogue. The pitting corrosion characteristics and corrosion resistance of the 8090 alloy have been determined in relation to precipitation microstructures. (orig.).

1990-06-01

379

ELECTRON MICROSCOPE PREPARATIONS OF RADIOACTIVELY LABELED AEROSOLS  

Science.gov (United States)

A method is described to smear extremely thin layers of nuclear emulsion on labeled electron microscope preparations and to measure the thicknesses of these layers, Without further separation, preparation and emulsion can be observed after exposure and development in an electron microscope. The source of the tracks formed in the emulsion can be exactly identified and the size and structure determined. This method finds applications in dust research and also in the analysis of medical and biological sections. Further information can be obtained about properties of different emulsions. (auth)

1963-04-01

380

Determination of habitual physical activity by means of a portable R-R interval distribution recorder  

UK PubMed Central (United Kingdom)

A new portable apparatus—the Interval Distribution Recorder (IDR)—has been developed by WHO for assessing habitual physical activity. It measures R-R intervals and records counts in...Full Text Available

1974-01-01

381

Determination of cesium and selenium in cultivated mushrooms using radionuclide X-ray fluorescence technique  

International Nuclear Information System (INIS)

Cesium and selenium intake of cultivated mushrooms (Agaricus bisporus), with these elements previously added to culture medium, has been examined from the viewpoint of health- and environmental protection. The process of measuring has been carried out by the radionuclide X-ray fluorescence technique. Treatments of the elementary substance with Se salt appears to influence the Se content of the mushrooms to a significant extent. Cs intake is of considerable importance, as this element is accumulated by mushrooms. (author)

2000-09-01

382

Determination by enzyme-linked immunosorbent assay of immunoglobulin G (IgG), IgM, and IgA to Brucella melitensis major outer membrane proteins and whole-cell heat-killed antigens in sera of patients with brucellosis.  

UK PubMed Central (United Kingdom)

An enzyme-linked immunosorbent assay was used to compare Brucella melitensis major outer membrane proteins (MOMP) and whole-cell heat-killed antigens (HK) in measuring antibrucella immunoglobulin G...Full Text Available

1989-08-01

383

Density changes in amorphous Pd{sub 80}Si{sub 20} during low temperature ion irradiation  

Energy Technology Data Exchange (ETDEWEB)

Density changes in amorphous Pd{sub 80}Si{sub 20} during ion irradiation below 100K were detected by in situ HVEM measurements of the changes in specimen length as a function of ion fluence. A decrease in mass density as a function of the ion fluence was observed. The saturation value of the change in mass density was determined to be approximately -1.2%.

1994-11-01

385

Computer simulation and radiation hardening of power devices to protect against failures induced by heavy ions  

International Nuclear Information System (INIS)

Power devices such as MOSFETSs and IGBTs, include parasitic structures that can give rise to destructive failures such as breakdown and latch-up. To determine a suitable strategy for device radiation hardening, simulation software like MEDICI-2D can be used to model the effects of technological modifications and device parameters that are difficult to measure experimentally. (authors).

386

Comparison of SAND-II and FERRET  

Science.gov (United States)

A comparison was made of the advantages and disadvantages of two codes, SAND-II and FERRET, for determining the neutron flux spectrum and uncertainty from experimental dosimeter measurements as anticipated in the FFTF Reactor Characterization Program. This comparison involved an examination of the methodology and the operational performance of each code. The merits of each code were identified with respect to theoretical basis, directness of method, solution uniqueness, subjective influences, and sensitivity to various input parameters.

387

Bounding ingestion stream-tube determination via a CO tracer  

Energy Technology Data Exchange (ETDEWEB)

A gas tracer technique based on carbon monoxide and a commercial automotive exhaust gas analyser has been applied to wind tunnel models of waterjet propulsion systems intakes. The post-processing and interpretation of the carbon monoxide concentration signals has yielded high resolution measurements of the bounding ingestion stream-tubes. (orig.) With 3 figs., 1 tab., 8 refs.

1998-05-01

388

Anomalous sputter yields due to cascade mixing  

Energy Technology Data Exchange (ETDEWEB)

Sputter-removal rates of overlayer and interfacial species on silicon are analyzed to determine sputtering yields for the species involved. Sputtering yields up to two orders of magnitude lower than those measured for silicon are found, and the results are interpreted in terms of a cascade mixing process which continually reburies much of the overlayer material beyond the escape depth of the sputtered atoms.

1980-05-01

389

Anomalous sputter yields due to cascade mixing  

International Nuclear Information System (INIS)

Sputter-removal rates of overlayer and interfacial species on silicon are analyzed to determine sputtering yields for the species involved. Sputtering yields up to two orders of magnitude lower than those measured for silicon are found, and the results are interpreted in terms of a cascade mixing process which continually reburies much of the overlayer material beyond the escape depth of the sputtered atoms.

390

Anomalous solvent extraction behavior of astatine  

International Nuclear Information System (INIS)

We studied the solvent extraction behavior of astatine and found the anomalous behavior of this element similar to radioiodine. Astatine was extracted into CS_2 from acidic solution over a wide range of carrier iodine concentration. The distribution ratios of astatine were determined by measuring the #gamma#-ray from 210 At with a NaI(Tl) detector. A drastic change was observed around at 10"-"4 mol/l as in the case of 131 l. This tendency is well explained by the kinematics of the chemical reactions concerned. (author).

391

An instrument for measuring spatial and time characteristics of sea agitation in coastal zones  

Energy Technology Data Exchange (ETDEWEB)

Resistive analogous meters for spatial and time characteristics in ocean agitation are most often used in practical oceanography in coastal zones but are based on bridge circuits determined to have shortcomings in their linearity range. This shortcoming is eliminated in the circuit of an instrument developed in an oceanographic laboratory (IMIO, Vana). Principle and block circuits are indicated, and static calibration curves are presented as are the correlative functions in the frequency spectrums obtained with the help of sea agitation recorded at a fixed point and at a depth of 6 meters.

1981-01-01

392

A tube inspection device. Dispositif de controle de tubes  

Energy Technology Data Exchange (ETDEWEB)

The device, aimed at non destructive control of the inner side of tubes such as steam generator tubes, is composed of a control sensor mounted on a support; the sensor head may rotate in the tube and a measuring system and signal processing allow for the exact determination of the angular position of the sensor head (application to ultrasonic or eddy current probes).

1993-05-07

393

A non-invasive approach for the determination of rumen pH  

Environmental Research Database

DescriptionAt present, measurement of rumen pH for differnt diets and feeding regimes is only possible through direct sampling of the rumen fluid. Such invasive procedures are not practical at the farm level and they have ethical implications for research programmes. This approach also has limitations to its reliability due to spatial variations in acidity within the rumen. Mathematical modelling offers a non-invasive real-time alternative for monitoring rumen pH, and the purpose of the research propose [continued...

2004-01-31

394

{sup 252}Cf-source-driven noise analysis measurements for characterization of concrete highly enriched uranium (HEU) storage vaults  

Energy Technology Data Exchange (ETDEWEB)

The {sup 252}Cf-source-driven noise analysis method has been used in measurements for subcritical configurations of fissile systems for a variety of applications. Measurements of 25 fissile systems have been performed with a wide variety of materials and configurations. This method has been applied to measurements for (1) initial fuel loading of reactors, (2) quality assurance of reactor fuel elements, (3) fuel preparation facilities, (4) fuel processing facilities, (5) fuel storage facilities, (6) zero-power testing of reactors, and (7) verification of calculational methods for assemblies with the neutron k < l. These previous measurements, performed with a wide variety of multiplying systems, demonstrated the usefulness of the method. The high sensitivity of noise-measured parameters to small changes in fissile systems has been observed in several ...

1993-10-01

395

Tetracycline treatment of periodontal disease in the beagle dog  

Energy Technology Data Exchange (ETDEWEB)

Bone-seeking radiopharmaceutical uptake (BSRU) was used to examine alveolar bone metabolism in a longitudinal study of tetracycline efficacy in beagle dogs. BSRU was measured in untreated control dogs and in beagles receiving either 250 mg or 500 mg oral tetracycline-HCl daily for 16 months. The rate of bone loss was determined for radiographs taken semiannually for a 6-month pretreatment period and for a 24-month treatment period. Measurements of BSRU obtained at month 16 of treatment were correlated with rates of bone loss determined radiographically in an attempt to determine whether BSRU was indicative of the subsequent rate of bone loss. A reduced rate of alveolar bone loss was found in the 500 mg tetracycline group at month 16 of the study relative to the untreated controls which was consistent with the decreased bone-seeking radiopharmaceutical uptake observed in this group. ...

1982-01-01

396

Neutron capture therapy beam on the LVR-15 reactor  

Energy Technology Data Exchange (ETDEWEB)

Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head ...

1992-01-01

397

Neutron capture therapy beam on the LVR-15 reactor  

International Nuclear Information System (INIS)

Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head ...

1991-10-01

398

Differential flux measurement of atmospheric pion, muon, electron and positron energy spectra at balloon altitudes  

Energy Technology Data Exchange (ETDEWEB)

The fluxes of atmospheric electrons, positrons, positive and negative muons and negative pions have been determined using the NMSU Wizard-MASS2 balloons-borne instrument. The instrument was launched from Fort Sumner, New Mexico, (geomagnetic cut-off about 4.5 GV/c) on september 23, 1991. The flight lasted 9.8 hours and remained above 100.000 ft. Muons and negative pions were observed and their momenta were determined. Since these particles are not a part of the primary component, the measurement of their fluxes provides information regarding production and propagation of secondary particles in the atmosphere. Similarly, observations of electrons and positrons well below the geomagnetic cut-off provides insight into electromagnetic cascade processes in the upper atmosphere. In addition, the determination of the energy spectra of rare particles such as positrons can be used for background subtraction for ...

1995-09-01

399

Corrosion of 304 stainless steel in molten-carbonate fuel cells  

Energy Technology Data Exchange (ETDEWEB)

The corrosion behavior of 304 stainless steel was characterized with cyclic voltammetry in a eutectic Li/K and Li/Na carbonate melt under anode and cathode gas of the molten-carbonate fuel cell (MCFC). The corrosion rate of 304 steel was determined in four different environments of the MCFC with electrochemical methods and from cross-sectional analysis of corrosion layers. These four environments were open-circuit and MCFC-load conditions both under anode and cathode gas. At open-circuit conditions corrosion was more severe under the oxidizing cathode gas then under the reducing anode gas. On the contrary, at load conditions corrosion was more severe under anode than under cathode gas. The anodic polarization under anode gas enhances corrosion, whereas the high anodic polarization under cathode gas leads to anodic protection. Corrosion currents were measured with chronoamperometry and determined with Tafel extrapolation ...

1999-07-01

400

Prompt fission neutron energy spectra induced by fast neutrons  

International Nuclear Information System (INIS)

Prompt fission neutron energy spectra for "2"3"5U and "2"3"9Pu have been measured for fission neutron energies greater than the energy of the incident neutrons inducing fission. The measurements were undertaken to investigate the shape dependence of the fission neutron spectra upon both the incident neutron energy and the mass of the nucleus undergoing fission. Measurements were made for both nuclides at incident neutron energies of 0.50, 1.50, 2.50 and 3.50 MeV. The data are presented either as relative yields or as ratios of measured spectra to that of "2"3"5U at 0.50 MeV. Incident neutrons were produced by the "7Li(p,n)"7Be reaction using a pulsed, bunched proton beam from the 5.5 MV Van de Graaff accelerator at the University of Massachusetts Lowell Radiation Laboratory. Fission neutrons were detected by a thin liquid scintillator with good time resolution capabilities. Neutron energies were ...

401

Incident angle modifiers for flat-plate solar collectors: analysis of measurement and calculation procedures  

Energy Technology Data Exchange (ETDEWEB)

Existing test procedures for measuring and rating thermal performance require the determination of the angular response of collectors in order to account for nonnormal incident beam irradiance. Angular response measurements for four different types of collectors, each type tested by three different laboratories, are presented and analyzed. Substantial differences, both within and between laboratories, are reported for the same type collectors. An analysis of the measurement procedure shows that experimentally determined angular response parameters are subject to relatively large uncertainties. The problem results to a large extent from measuring collector efficiencies at non-normal incident angles where measurement uncertainty is of the same order of magnitude as the efficiency reduction attributable to these off-normal angles. Other factors ...

1982-11-01

402

Measurements of water vapor adsorption on the Geysers rocks  

Energy Technology Data Exchange (ETDEWEB)

The ORNL high temperature isopiestic apparatus was adapted for adsorption measurements. The quantity of water retained by rock samples taken from three different wells of The Geysers was measured at 150 °C and at 200 °C as a function of pressure in the range 0.00 ≤ p/p0 ≤ 0.98, where p0 is the saturated water vapor pressure. The rocks were crushed and sieved into three fractions of different grain sizes (with different specific surface areas). Both adsorption (increasing pressure) and desorption (decreasing pressure) runs were made in order to investigate the nature and extent of the hysteresis. Additionally, BET surface area analyses were performed by Porous Materials Inc. on the same rock samples using nitrogen or krypton adsorption measurements at 77 K. Specific surface areas and pore volumes were determined. These parameters ...

1996-01-24

403

Thickness measurement of Sn-Ag hot dip coatings on Large Hadron Collider Superconducting strands by coulometry  

CERN Document Server

Amperostatic coulometry was applied for the thickness measurement of Sn-Ag hot dip coatings, which comprise an extended Sn-Cu interdiffusion layer. Complementary measurements, notably weight loss, X-ray photoelectron spectroscopy, energy-dispersive X-ray spectroscopy, X-ray fluorescence (XRF), and dynamic secondary ion mass spectroscopy were performed in order to obtain a better interpretation of the coulometry results. Based on the experimental results presented in this article, the three potential changes observed during coulometry measurements are ascribed to (i) the entire dissolution of pure Sn, (ii) the formation of a CuCl salt layer, and (iii) the surface passivation. The measurement of the pure Sn mass is well reproducible despite strong coating thickness variations detected by XRF. Several experimental problems, in particular, a coating undercutting, hamper the ...

2004-01-01

404

Plastic zone and pileup around large indentations  

International Nuclear Information System (INIS)

Mechanical properties of cold-worked molybdenum, grade 4 titanium, and an #alpha#-#beta# titanium alloy are measured with tensile tests and by indentations using conical indenters with 105, 120, and 137 deg included angles. The extent of plastic deformation and pileup around an indentation is measured using profilometry. Various models predicting the extent of plastic deformation and pileup are compared to the actual measured values. As inferred from indentation, the calculated yield strength of the material from the mean pressure does not correlate well to the yield strength measured by tensile testing. The plastic zone size surrounding an indentation can also be used to determine the yield strength of the material, and this does correlate to the yield strength measured by tensile tests. Furthermore, the extent of plastic deformation is relatively independent ...

405

Measurement of the concentration of coal slurry using microwave techniques; Maikuroha wo oyoshita konodo sekitan slurry no nodo sokutei ni tsuite  

Energy Technology Data Exchange (ETDEWEB)

The paper reported on an experiment on measurement of concentration of highly concentrated coal slurry using microwaves carried out at Miike coal preparation works. The purpose of the experiment was to investigate applicability of microwave moisture content measurement of slurry of a mixture of coal and coal particles and to use it to the control of process such as coal preparation and processing. In the experiment, a method for measuring the slurry concentration was adopted in which the container filled with highly concentrated coal slurry was irradiated with microwaves and the damping of strength of the penetrating microwaves was detected. As a result of the experiment, it was found out that there was a big correlation between the capacitive concentration of slurry and the damping ratio of microwaves. When irradiating slurry with microwaves of 1GHz frequency, a big correlation between the concentration and the damping ...

1996-09-30

406

First direct mass measurement of the proton rich nuclides {sup 85,86,87}Mo and {sup 87}Tc  

Energy Technology Data Exchange (ETDEWEB)

The masses of proton rich nuclides in the vicinity of N=Z=43 were measured with the Penning trap mass spectrometer SHIPTRAP at GSI. These nuclei were produced in the fusion-evaporation reaction {sup 36}Ar+{sup 54}Fe at energies of 5.0 and 5.9 MeV/u and separated at the velocity filter SHIP. The data are of astrophysical interest since these nuclei are believed to be a part of the rp and {nu}p process paths. The masses of {sup 85}Mo and {sup 87}Tc were measured for the first time. The masses of another two nuclides, {sup 86,87}Mo, were determined for the first time in a direct mass measurement. For these nuclides the mass excess deviates from values of the 2003 Atomic Mass Evaluation by up to 1.5 MeV, indicating a systematic shift of the mass surface in this region of the nuclear chart. Additionally, the masses of {sup 86}Zr and {sup 85}Nb were measured and found to be in agreement ...

2009-07-01

407

First direct mass measurement of the proton rich nuclides "8"5","8"6","8"7Mo and "8"7Tc  

International Nuclear Information System (INIS)

The masses of proton rich nuclides in the vicinity of N=Z=43 were measured with the Penning trap mass spectrometer SHIPTRAP at GSI. These nuclei were produced in the fusion-evaporation reaction "3"6Ar+"5"4Fe at energies of 5.0 and 5.9 MeV/u and separated at the velocity filter SHIP. The data are of astrophysical interest since these nuclei are believed to be a part of the rp and #nu#p process paths. The masses of "8"5Mo and "8"7Tc were measured for the first time. The masses of another two nuclides, "8"6","8"7Mo, were determined for the first time in a direct mass measurement. For these nuclides the mass excess deviates from values of the 2003 Atomic Mass Evaluation by up to 1.5 MeV, indicating a systematic shift of the mass surface in this region of the nuclear chart. Additionally, the masses of "8"6Zr and "8"5Nb were measured and found to be in agreement with the values obtained ...

2009-03-16

408

Application of passive and active methods parallel to the measurements of local climatic parameters for the assessment of Rn-222 behaviour in selected Swiss dwellings  

International Nuclear Information System (INIS)

Sources of radon and pathways in which radon can reach dwelling-rooms are shortly discussed. In continuation of the previous measurements of radon in Swiss dwellings with track detectors and working level monitors, a complementary passive method for radon concentration measurements indoors and radon exhalation rate measurements from walls and soil surfaces is introduced. Radon decay products concentrations, air temperature gradients and wind velocities were measured continuously in four Swiss dwellings during several weeks in autumn and winter of 1985/86. The Rn-222 concentrations indoors ranged from about 10 Bq/m"3 in two houses in the Eastern Jura up to more than 23,000 Bq/m"3 in two houses situated in the Central Alps. Indoor equilibrium factors between 0.1 up to 0.5 with distinct dependences on floor-levels have been found. The influence of the temperature gradient between the oudoor and indoor air ...

409

Nuclear charge radii of light isotopes based on frequency comb measurements  

Energy Technology Data Exchange (ETDEWEB)

Optical frequency comb technology has been used in this work for the first time to investigate the nuclear structure of light radioactive isotopes. Therefore, three laser systems were stabilized with different techniques to accurately known optical frequencies and used in two specialized experiments. Absolute transition frequency measurements of lithium and beryllium isotopes were performed with accuracy on the order of 10{sup -10}. Such a high accuracy is required for the light elements since the nuclear volume effect has only a 10{sup -9} contribution to the total transition frequency. For beryllium, the isotope shift was determined with an accuracy that is sufficient to extract information about the proton distribution inside the nucleus. A Doppler-free two-photon spectroscopy on the stable lithium isotopes {sup 6,7}Li was performed in order to determine the absolute frequency of the 2S {yields} 3S transition. The ...

2010-02-11

410

Studies on the chemical composition and possible mechanisms underlying the antispasmodic and bronchodilatory activities of the essential oil of Artemisia maritima L.  

British Library Electronic Table of Contents (United Kingdom)

This study describes the chemical composition of the essential oil of Artemisia maritima (Am.Oil) and the pharmacological basis for its medicinal use in gut and airways disorders. Twenty five compounds, composing 93.7% of the oil, were identified; among these, chrysanthenyl propionate and elixene were identified for the first time from any Artemisia species. The Am.Oil (0.3?1.0 mg/mL) suppressed spontaneous and high K+ (80 mM)-induced contractions in isolated rabbit jejunum, suggestive of an antispasmodic effect mediated possibly through calcium channel blockade. The calcium channel blockade activity was confirmed when pre-treatment of the tissue with Am.Oil (0.01?0.03 mg/mL) shifted the Ca++ concentration-response curves to the right, similar to verapamil and papaverine. In isolated trach...

2011-01-01

411

Electrophysiological mechanisms of sophocarpine as a potential antiarrhythmic agent  

British Library Electronic Table of Contents (United Kingdom)

Aim:To examine the electrophysiological effects of sophocarpine on action potentials (AP) and ionic currents of cardiac myocytes and to compare some of these effects with those of amiodarone.Methods:Langendorff perfusion set-up was used in isolated guinea pig heart, and responses to sophocarpine were monitored using electrocardiograph. Conventional microelectrode, voltage clamp technique and perforated patch were employed to record fast response AP (fAP), slow response AP (sAP) and ionic currents in guinea pig papillary muscle or rabbit sinus node cells.Results:Tachyarrhythmia produced by isoprenaline (15 ?mol/L) could be reversed by sophocarpine (300 ?mol/L). Sophocarpine (10 ?mol/L) decreased the amplitude by 4.0%, maximal depolarization velocity (Vmax) of the fAP by 24.4%...

2011-01-01

412

Characterization of the platelet-aggregating activity of tumor cells. [Mice  

Energy Technology Data Exchange (ETDEWEB)

Two lines of mouse tumor cells were shown to be capable of aggregating mouse and rabbit platelets in vitro. This process required higher Mg/sup 2 +/ concentrations than were needed by other commonly used platelet-aggregating agents. Platelet-aggregating activity was also found in tumor cell membrane fragments. This membrane-bound platelet-aggregating material contained protein, lipid, and carbohydrate moieties. The presence of all three appeared to be essential for stimulating platelet aggregation. Destruction of any component abolished its activity. Platelet aggregation induced by tumor cell membrane fragments was associated with a secretory release reaction. In this process, growth-promoting activity for tumor cells was also released from platelets. These results underline the importance of platelets in establishing tumor metastases.

1980-04-01

413

Annual report of JMTR, 1994. April 1, 1994 - March 31, 1995  

Energy Technology Data Exchange (ETDEWEB)

In FY1994, JMTR was in operation during 4 operation cycles with low enriched Uranium(LEU,20%) fuel for irradiation study of nuclear fuels and materials and for radioisotope production. Irradiation studies were carried out using capsules, Oarai Gas Loop-1(OGL-1), Oarai Shroud Facility(OSF-1) and hydraulic rabbits irradiation facilities in support of LWR, FBR, HTTR and thermonuclear reactor. Irradiation studies on blanket materials were intensively carried out. Power ramping tests were carried out and the future program is under consideration. For R and D works, neutron spectrum evaluation technology, re-instrumentation technique for irradiation fuel rod, remote controlled SEM apparatus and examination technique with miniaturized specimens were successfully developed. (author).

1996-03-01

414

Amino acid substitution: its use in detection and analysis of genetic variants  

International Nuclear Information System (INIS)

Techniques of chemical analysis, amino acid sequencing and autoradiography are being used to study the frequency of incorporation of normally noncoded amino acids into hemoglobins and seminal fluid proteins. We are studying, by the sequencing of radiolabeled proteins followed by the recovery of ["3H] isoleucine phenylthiohydantoin by high-performance liquid chromatography, the frequency at which normally noncoded isoleucine is incorporated into hemoglobin because of base-substitution mutations versus translational errors. Irradiation increases the isoleucine content of human hemoglobin and the frequency of substitution of isoleucine for specific amino acids in rabbit hemoglobin. Studies to date indicate that these techniques have been developed sufficiently for initial analysis of the potential of drugs and environmental pollutants to induce base-substitution mutations in mammalian somatic cells.

415

Aldehyde dehydrogenase (ALDH) 3A1 expression by the human keratocyte and its repair phenotypes  

British Library Electronic Table of Contents (United Kingdom)

Transparency is essential for normal corneal function. Recent studies suggest that corneal cells express high levels of so-called corneal crystallins, such as aldehyde dehydrogenase (ALDH) and transketolase (TKT) that contribute to maintaining cellular transparency. Stromal injury leads to the appearance of repair phenotype keratocytes, the corneal fibroblast and myofibroblast. Previous studies on keratocytes from species such as bovine and rabbit indicate that the transformation from the normal to repair phenotype is accompanied by a loss of corneal crystallin expression, which may be associated with loss of cellular transparency. Here we investigated if a similar loss occurs with human keratocyte repair phenotypes. Human corneal epithelial cells were collected by scraping and keratocytes...

2006-01-01

416

Thermal-neutron capture cross section and resonance integral of americium-241  

International Nuclear Information System (INIS)

The thermal-neutron capture cross section (#sigma#_0_,_g) and the resonance integral (I_0_,_g) leading to the ground state of "2"4"2Am were measured by an activation method for neutron capture by "2"4"1Am. A method with gadolinium, which was similar to the cadmium difference method, was used to measure the cross section #sigma#_0_,_g with attention to resonances of "2"4"1Am. Americium chloride samples containing "2"4"1Am radioisotope were irradiated for 68 h in the long-irradiation plug of the Kyoto University Research Reactor, KUR. Wires of Co/Al and Au/Al alloys were used as monitors to determine thermal-neutron fluxes and epithermal Westcott's indexes at the irradiation positions. An #alpha#-ray spectrometer was used to measure the activity ratios of "2"4"2Cm to "2"4"1Am. On the basis of Westcott's convention, the #sigma#_0_,_g and I_0_,_g values were determined as 628#+-#22 b ...

2007-12-01

417

The End of Amnesia: A New Method for Measuring the Metallicity of Type Ia Supernova Progenitors Using Manganese Lines in Supernova Remnants  

CERN Document Server

We propose a new method to measure the metallicity of Type Ia supernova progenitors using Mn and Cr lines in the X-ray spectra of young supernova remnants. We show that the Mn to Cr mass ratio in Type Ia supernova ejecta is tightly correlated with the initial metallicity of the progenitor, as determined by the neutron excess of the white dwarf material before thermonuclear runaway. We use this correlation, together with the flux of the Cr and Mn Kalpha X-ray lines in the Tycho supernova remnant recently detected by Suzaku (Tamagawa et al. 2008) to derive a metallicity of log(Z) = -1.32 (+0.67,-0.33) for the progenitor of this supernova, which corresponds to log(Z/Zsun)= 0.60 (+0.31,-0.60) according to the latest determination of the solar metallicity by Asplund et al. (2005). The uncertainty in the measurement is large, but metallicities much smaller than the solar value can be confidently discarded. We ...

2008-01-01

418

Photoconducting properties of ultraviolet detectors based on GaN and Al{sub 1{minus}x}Ga{sub x}N films grown by ECR-MBE  

Energy Technology Data Exchange (ETDEWEB)

GaN and Al{sub 1{minus}x}Ga{sub x}N films were grown by the method of ECR-MBE. Absorption constants as a function of wavelength were determined from transmission measurements. Photoconducting detectors were fabricated from these films and characterized in terms of their spectral response and photoconductive gain. Mobility-lifetime products were determined from the measurement of photoconductive gain. The resistivity and mobility-lifetime products of the films were varied from 10--10{sup 9} ohm-cm and 10{sup {minus}3}--10{sup {minus}8} cm{sup 2}/V respectively by changing the microwave power in the ECR discharge from 20--60 watts. The change in the mobility-lifetime product is attributed to change in the lifetimes of the photogenerated carriers. This assumption is supported by direct measurement of detector response times. Finally, the authors report for the first time, the detection ...

1997-12-31

419

Photoconducting properties of ultraviolet detectors based on GaN and Al_1_-_xGa_xN films grown by ECR-MBE  

International Nuclear Information System (INIS)

GaN and Al_1_-_xGa_xN films were grown by the method of ECR-MBE. Absorption constants as a function of wavelength were determined from transmission measurements. Photoconducting detectors were fabricated from these films and characterized in terms of their spectral response and photoconductive gain. Mobility-lifetime products were determined from the measurement of photoconductive gain. The resistivity and mobility-lifetime products of the films were varied from 10--10"9 ohm-cm and 10"-"3--10"-"8 cm"2/V respectively by changing the microwave power in the ECR discharge from 20--60 watts. The change in the mobility-lifetime product is attributed to change in the lifetimes of the photogenerated carriers. This assumption is supported by direct measurement of detector response times. Finally, the authors report for the first time, the detection of alpha particles using GaN detectors.

1996-12-02

420

Nuclear data implications for the reactor production of "1"8"8W  

International Nuclear Information System (INIS)

Calculations have been made to determine the production of "1"8"8W from "1"8"6W in several US fission reactor systems, e.g., Fast Flux Test Facility (FFTF), the High Flux Isotope Reactor (HFIR), and the Advanced Test Reactor (ATR). Important input to these calculations are the cross-section parameters for "1"8"6W, "1"8"7W, and "1"8"8W. Only two values have been measured for "1"8"7W and none for "1"8"8W. Consequently, results from integral measurements play a crucial role in determining the "1"8"7W and "1"8"8W values. This has been studied for irradiations in the FFTF and the Oregon State Univ. (OSU) research reactor. Short irradiation of enriched "1"8"6W in both the FFTF and the OSU reactors have produced #mu#Ci/g quantities of "1"8"8W/"1"8"8Re. Measurements were made of the "1"8"8W gamma ray emission. These results were incorporated with other available data to provide more ...

1992-08-23

421

Micro-hardness measurements to evaluate composition gradients in metal-based functionally graded materials  

Energy Technology Data Exchange (ETDEWEB)

Micro-Vickers hardness measurement has been used to determine the composition of functionally graded materials (FGMs). Materials used in the present study are Al-SiC, Al-Shirasu and Al-Al{sub 3}Ni FGMs, which are fabricated by a centrifugal method. The micro-hardness of the aluminum matrix for Al-SiC FGM markedly increases as the volume fraction of SiC particles increases. However, the tendency is not so clear in the cases of Al-Shirasu and Al-Al{sub 3}Ni FGMs. Plastic strain energy due to thermal misfits between the matrix and dipersed particles is calculated based on an elasto-plastic analysis by applying a shell theory after Lee et al. The hardness is correlated theoretically with the composition gradient through the mean plastic strain energy (responsible for dislocation density). It is concluded that the composition gradient of metal-based FGMs can be determined from micro-hardness measurements. ...

2001-01-01

422

Automatic system for measuring dose-area product (DAP) in ROI fluoroscopy  

Energy Technology Data Exchange (ETDEWEB)

A computerized system for monitoring dose-area product (DAP) has been developed for region of interest (ROI) fluoroscopy in which patient exposure is reduced using an x-ray attenuating filter with an aperture. The system includes an IBM compatible computer which is connected through an IEEE-488 interface to an electrometer which measures the charge from a DAP ionization chamber. A digital input/output board connects the computer to the filter placement device to determine whether the filter is in or out of the beam, and to the x-ray generator to determine when the exposure is due to spot filming. The computer logs the DAP from conventional fluoroscopy, ROI fluoroscopy and spot filming separately, applying the appropriate calibration factor for each. Measured DAPs, fluoroscopic DAP rates and exposure times are displayed in real-time. The system has been installed in a GI fluoroscopic room so that the ...

1997-04-01

423

Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel  

International Nuclear Information System (INIS)

In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning measurements on 31 spent PWR fuel assemblies performed ...

424

Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel  

Energy Technology Data Exchange (ETDEWEB)

In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning measurements on 31 spent PWR fuel assemblies performed ...

2007-03-15

425

A hydroxide mixture as working fluid for absorption heat pumps  

Energy Technology Data Exchange (ETDEWEB)

Basic experimental investigations were carried out with an aqueous solution of a mixture of KOH and NaOH for use as an absorbent in absorption heat pumps. Due to its thermophysical properties this mixture allows temperature lifts from evaporator to absorber of more than 75 K (135 F) in a single-stage absorption chiller. Thermophysical and hydrodynamical properties of the solution were measured. Vapor-liquid-equilibrium data and specific heat capacities were determined for concentrations ranging from 35% up to 75% and temperatures up to 200 C (392 F). From these data the enthalpy of the solution was calculated. Additionally the crystallization temperatures, the density, and the viscosity of the solution were determined. The experimental equipment is described. The data are presented as polynomials and diagrams including experimental accuracy. An apparatus was constructed to measure heat and mass transfer ...

1996-11-01

426

High-resolution magnetic resonance imaging: three-dimensional trabecular bone architecture and biomechanical properties.  

Science.gov (United States)

The purpose of this study was to use high-resolution magnetic resonance (MR) imaging combined with image analysis to investigate the three-dimensional (3D) trabecular structure, anisotropy, and connectivity of human vertebral, femoral, and calcaneal specimens. The goal was to determine whether: (a) MR-derived measures depict known skeletal-site-specific differences in architecture and orientation of trabeculae; (b) 3D architectural parameters combined with bone mineral density (BMD) improve the prediction of the elastic modulus using a fabric tensor formulation; (c) MR-derived 3D architectural parameters combined with BMD improve the prediction of strength using a multiple regression model, and whether these results corresponded to the results obtained using higher resolution depictions of trabecular architecture. A total of 94 specimens (12 x 12 x 12 mm cubes) consisting of trabecular bone only were obtained, of which there were 7 from the ...

1998-05-01

427

Thermogravimetric and specific heat determinations of a commercial reconcentrated sample of ulexite, between room temperature and 1,000 degree centigree; Determinaciones termogravimetricas y de calor especifico de un concentrado comercial de ulexita, entre temperature ambiente y 1.000 grados centigrados  

Energy Technology Data Exchange (ETDEWEB)

The important amount of hydration water in the ulexite (NaCaN{sub 5}O{sub 9}.8H{sub 2}O), allows using calcination methods to increase its B{sub 2}O{sub 3} content. This paper analyses the thermal decomposition reaction of a preconcentrated ulexite through weight loss measurements, which occur during the heating of samples until 1000 degree centigree, Determinations of heat content at each temperature were made using an isoperibol calorimeter. The mean specific heat was calculated from these values, and its dependence on temperature was determined. The maximum weight loss was about 32.5% and the specific heat obtained was 1,13 kJ/kg 0 C for solid samples and 1,38 kJ/kg''0 C for fluid samples. The results are useful for the design of the industrial process, in order to determine the thermal requirements for heating calcined ulexite, and to obtain smelted ulexite. (Author) 19 refs.

2006-07-01

428

Radioanalytical methods of rare earth element determination  

International Nuclear Information System (INIS)

Instrumental neutron activation analysis (INAA) and radionuclide X-ray fluorescence analysis (RXFA) were used for the determination of rare earth elements. For INAA, solution obtained by sample decomposition was dripped onto filter paper, enclosed and sealed into a polyethylene foil. The sample was activated in reactor WWR-S over a period of 4 to 6 hours with a neutron fluence of 10"1"3cm"-"2. Gamma radiation measurement was carried out with a planar and a coaxial HP-Ge detector in three decay periods. La, Ce, Nd, Sm, Eu, Gd, Tb, Ho, Tm, Yb and Lu were determined. The advantage of the method is its accuracy and high sensitivity, the disadvantage is the time-consuming analysis. The RXFA method was used as a rapid and operative method for the analysis of loose ore samples, aqueous and organic solutions of rare earth elements. For exciting X-ray radiation, "2"4"1Am was used and the radiation of K-lines was detected with a ...

1989-06-01

429

Determination of trace elements in Syrian medicinal plants and their infusions by energy dispersive X-ray fluorescence and total reflection X-ray fluorescence spectrometry  

Energy Technology Data Exchange (ETDEWEB)

X-ray fluorescence (XRF) and total-reflection X-ray fluorescence (TXRF) techniques suited well for a multi-element determination of K, Ca, Mn, Fe, Cu, Zn, Rb, and Sr in some Syrian medicinal plant species. The accuracy and the precision of both techniques were verified by analyzing the Standard Reference Materials (SRM) peach-1547 and apple leaves-1515. A good agreement between the measured concentrations of the previously mentioned elements and the certified values were obtained with errors less than 10.7% for TXRF and 15.8% for XRF. The determination of Br was acceptable only by XRF with an error less than 24%. Furthermore, the XRF method showed a very good applicability for the determination of K, Ca, Mn, Fe, Cu, Zn, Rb, Sr, and Br in infusions of different Syrian medicinal plant species, namely anise (Anisum vulgare), licorice root (Glycyrrhiza glabra), and white wormwood (Artemisia herba-alba)

2009-07-15

430

Automated method for determining location and magnitude of leaks inside a PWR containment  

Energy Technology Data Exchange (ETDEWEB)

Thermal-hydraulics analysis can be used to determine location and magnitude of leaks inside a pressurized water reactor (PWR) containment, as required by plant technical specifications. The major advantage of this detection method is that it minimizes radiation exposure of maintenance personnel because most of the leak detection process is performed from the control room outside the containment. In addition, such a program allows for the elimination of pipe whip restraints and jet impingement shields, eliminating costs for maintenance of these supports and shields in older plants and lowering construction costs for new plants. Previously, only simple single-node containment models were used for determining leakage magnitude. This paper presents a more sophisticated multinode approach for determining the magnitude and location. The resulting sensitivities to leak can be programmed into the plant's computer system. ...

1986-01-01

431

Measurement of magnetic fields in the Area Metropolitana  

International Nuclear Information System (INIS)

The operation and proper handling of equipment for measuring EMR-300 electromagnetic waves are studied and apply that knowledge to determine which areas of the metropolitan area are mostly affected by exposure to the emission of radiation. This team is able to measure magnetic field strength, electric field strength and power density, also can measure the most important parameters in a simple manner. International standards provide maximum values for these parameters that limit human exposure to such radiation. These standards are based on epidemiological several and laboratory that have been carried out in order to determine in which circumstances a biological entity is exposed to a level of radiation that can cause harm to their health. It focuses on measuring the level of radiation in certain areas of interest, which were chosen because are areas with high ...

432

Effect of Collimation Slit and Shield Thickness in a Prompt Gamma-based Proton Beam Range Measurement System  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has a unique advantage over the electron and photon beams in that it can give very high radiation dose to the tumor volume, while effectively sparing the neighboring healthy tissue and organs. For the clinical application of the proton beam, it is very important to confirm the location of the proton beam in the patient, preferentially during the treatment. It has been suggested that the range of the proton beam in the patient can be determined by measuring prompt gammas from the proton beam passage. Recently, a prototype prompt-gamma scanning system has been constructed and tested using experimental and therapeutic proton beams. The measurement results for the proton beams of 70 . 230 MeV showed that a clear correlation exists between the distribution of the prompt gammas and the proton beam range. The scanning method, however, is not suitable for the upcoming 'spot scanning' technique. The ...

2007-07-01

433

Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden  

Energy Technology Data Exchange (ETDEWEB)

The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of ...

2007-11-15

434

Measurement and analysis of neutron production cross sections and determination of some reaction rates for nuclear astrophysical calculations  

International Nuclear Information System (INIS)

The absolute cross sections of "2"3Na(p,n)"2"3Mg, "2"7Al(p,n)"2"7Si and "3"0Si(#alpha#,n)"3"3S reactions were measured in the incident energy range of 5.05 to 5.80, 5.80 to 6.25 and 3.975 to 6.235 MeV respectively using a spherically shaped 4#pi# neutron detector. In the energy range 5.80 to 7.80 and 6.235 to 11.30 MeV the absolute cross sections of "2"3Na(p,n)"2"3Mg and "3"0Si-(#alpha#,n)"3"3S reactions were determined by optical model calculations. The cross sections of the inverse reactions "2"3Mg(n,p)"2"3Na and "3"3S(n,#alpha#)"3"0Si were also calculated by the same method for the neutron energy range of 10 keV to 7.50 MeV for each reaction. The cross section of the latter reaction in the neutron energy range of 10 keV to 840 keV was also determined from its inverse reaction "3"0Si(#alpha#,n)"3"3S by the application of the detailed balance theorem. The reactions for which the cross sections were ...

435

Serine-324 of myosin's heavy chain is photoaffinity-labeled by 3 prime (2 prime )-O-(4-benzoylbenzoyl)adenosine triphosphate  

Energy Technology Data Exchange (ETDEWEB)

A portion of the active site of rabbit skeletal myosin near the ribose ring of ATP can be labeled by the photoaffinity analogue 3{prime}(2{prime})-O-(4-benzoylbenzoyl)adenosine triphosphate (Bz{sub 2}ATP). The specificity of the photolabeling was assured by first trapping ({sup 14}C)Bz{sub 2}ATP at the active site by use of thiol cross-linking agents. Five radioactive peptides were isolated by high-performance liquid chromatography after extensive trypsin and subtilisin digestion of photolabeled myosin subfragment 1. Four of these peptides were sequenced by Edman techniques, and all originated from a region with the sequence Gly-Glu-Ile-Thr-Val-Pro-Ser-Ile-Asp-Asp-Gln, which corresponds to rabbit myosin heavy chain residues 312-328. The fifth labeled peptide had an amino acid composition appropriate for residues 312-328. Amino acid composition, radiochemical analysis, and sequence data indicate that Ser-324 is the major amino acid residue ...

1989-05-02

436

Rapid inhibition of vasoconstriction in renal afferent arterioles by aldosterone  

DEFF Research Database (Denmark)

Aldosterone has been suggested to elicit vessel contraction via a nongenomic mechanism. We tested this proposal in microdissected, perfused rabbit renal afferent arterioles. Aldosterone had no effect on internal diameter in concentrations from 10(-10) to 10(-5) mol/L, but aldosterone abolished the ability of 100 mmol/L KCl to induce vascular contraction. The inhibitory effect of aldosterone was observed from 1 pmol/L. The inhibitory effect was significant after 5 minutes and maximal after 20 minutes and was fully reversible. Actinomycin D (10(-6) mol/L) prolonged the effect of aldosterone. The effect was abolished by the mineralocorticoid receptor antagonist spironolactone (10(-7) mol/L) but not by the glucocorticoid receptor antagonist mifepristone (10(-6) mol/L). The K+-mediated increase of intracellular calcium concentration in afferent arterioles was not affected by aldosterone. Mineralocorticoid receptor was detected by reverse transcription-polymerase chain ...

2003-01-01

437

Platelet receptor recognition domain on the. gamma. chain of human fibrinogen and its synthetic peptide analogues  

Energy Technology Data Exchange (ETDEWEB)

The authors have shown previously that the domain recognizing receptors on activated human platelets is located on the human fibrinogen {gamma} chain between residues 400 and 411. To study the correlation between the structure of this segment of the {gamma} chain and its reactivity toward receptors on ADP-activated human platelets, they designed a series of analogues containing replacements at 9 out of 12 positions. A double substitution of the normal His{sup 400}-His{sup 401} sequence by Ala-Ala reduced the inhibitory potency of the dodecapeptide 3-fold. When Lys{sup 406} was replaced by Arg, the inhibitory potency of the dodecapeptide decreased 15 times. On the other hand, substitution of Ala{sup 408} with Arg increased the inhibitory potency of the dodecapeptide 6-fold. A drastic decrease in the reactivity of the dodecapeptide toward platelet receptors was observed when Val{sup 411} was replaced by leucine or cysteine or tyrosine. A 3-fold decrease in reactivity was noted when ...

1989-04-04

438

Effects of holmium laser on dental structure in vivo: thermal evaluation and histological analysis on pulpal tissue; Efeitos in vivo do laser de holmio em estrutura dental: monitoracao termica e analise histologica do tecido pulpar  

Energy Technology Data Exchange (ETDEWEB)

Previous in vitro studies have demonstrated that Ho:YLF laser is capable of inducing physical and chemical changes on dental surfaces treated for caries prevention. The temperature in the pulp chamber was in vitro evaluated to as a function of the power and frequency of the laser irradiation. The purpose of this work is to verify the occurrence of pulp inflammation after Ho:YLF laser irradiation using different parameters in rabbits' teeth. The premolars and molars of ten rabbits (NZB) were divided in two groups according to the irradiation energy values of a Ho:YLF laser prototype operating at 2.065{mu}m wave length, frequency of O,5Hz and pulse length of 250{mu}s. An group A teeth were irradiated with using ten pulses of 334mJ/pulse of a Ho:YLF laser prototype operating at O.5Hz, and group B, with 512mJ/pulse. Animals were killed by transcardiac perfusion and the samples were prepared for histopathological analysis. The in vitro ...

2001-07-01

439

Cysteinyl peptides of rabbit muscle pyruvate kinase labeled by the affinity label 8-((4-bromo-2,3-dioxobutyl)thio)adenosine 5 prime -triphosphate  

Energy Technology Data Exchange (ETDEWEB)

The affinity label 8-((4-bromo-2,3-dioxobutyl)thio)adenosine 5{prime}-triphosphate (8-BDB-TA-5{prime}-TP) reacts covalently with rabbit muscle pyruvate kinase, incorporating 2 mol of reagent/mol of enzyme subunit upon complete inactivation. Protection against inactivation is provided by phosphoenolpyruvate, K{sup +}, and Mn{sup 2+} and only 1 mol of reagent/mol of subunit is incorporated. The authors have now identified the resultant modified residues. After reaction with 8-BDB-TA-5{prime}-TP at pH 7.0, modified enzyme was incubated with ({sup 3}H)NaBH{sub 4} to reduce the carbonyl groups of enzyme-bound 8-BDB-TA-5{prime}-TP and to introduce a radioactive tracer into the modified residues. Following carboxymethylation and digestion with trypsin, the radioactive peptides were separated on a phenylboronate agarose column followed by reverse-phase high-performance liquid chromatography in 0.1% trifluoroacetic acid with an acetonitrile gradient. Gas-phase sequencing ...

1990-03-13

440

Safe detection of Co-60. New perspectives in contamination and clearance measurements  

International Nuclear Information System (INIS)

Consistent application of a newly developed coincidence technique to determine activation products in the operation and demolition of nuclear facilities results in very new perspectives in contamination monitoring and clearance measurement of plant components. In particular, it is possible to avoid the critical spread of point-source Co-60 contamination, the so-called hot particles. The CCM (Cobalt Coincidence Measurement) technique includes the coincident detection of prompt-prompt gamma cascades with "6"0Co and other activation products ("1"1"0"mAg, "1"2"4Sb, "2"2Na) with low mass-specific limits for unrestricted clearance. Special features of the technique are the short measurement times, excellent signal-to-noise ratio, and focusing in space achieved. Compared to conventional integral gamma-measurements, the signal-to-background ratio can be improved by 1-2 orders of magnitude. ...

441

Analysis of delta-ferrite data from production stainless steel pipe welds  

Science.gov (United States)

An American Society of Mechanical Engineers task group on stainless steel weld materials was organized to determine the need for ferrite measurements of production welds required by the US Nuclear Regulatory Commission Regulatory Guide 1.31 (Rev. 1). The task group studied paired ferrite measurements (i.e., calculated and measured ferrite numbers (FNs) for the material qualifications versus measured ferrite numbers for corresponding production welds (PWs)). Our purpose was to compare delta-ferrite content as measured in the filler metal weld qualification pad with that in the resultant PW. Welds made predominantly by three common processes (submerged arc, shielded metal arc, and gas tungsten arc) were included in the study. Weld metals investigated included types 308, 308L, 316, and 316L stainless steel. An initial evaluation of the paired ferrite ...

1984-01-01

442

Use of measured time delays in gravitational lenses to determine the hubble constant  

Energy Technology Data Exchange (ETDEWEB)

Gravitational lenses are rare in the known samples of quasars, indicating that the conditions involved in their formation are unusual. In particular, the distribution of matter along the light rays from the observer through the deflector to the quasar may be very different from mean conditions. We show that reasonable deviations in the density of matter along the beams can significantly alter the relationship between time delays and the Hubble constant (H/sub 0/) and conclude that gravitational lenses are not promising estimators of H/sub 0/. However, should an independent, precise determination of H/sub 0/ become available, gravitational lenses could be used to probe long-range density fluctuations.

1985-04-15

443

Tracheal cross-sectional area in children: CT determination  

Energy Technology Data Exchange (ETDEWEB)

A computer method that calculates tracheal cross-sectional area by compensating for partial volume averaging was developed and validated in a study with phantoms. The program was then used to determine the tracheal cross-sectional area of 30 normal children who ranged in age from four months to 18 years. CT-derived cross sections were correlated with age, height, weight, and body-surface area, and they were compared with findings of published clinical and post-mortem studies. CT cross-sectional areas ranged from 20 to 275 mm/sup 2/, varied by as much as 22% at the three different tracheal levels studied, and appeared to correlate most closely with body height. CT-derived tracheal cross-sectional areas are quite similar to those in published reports of postmortem and clinical studies. Measurements of tracheal cross section by CT may prove useful in quantitating tracheal compromise by intrinsic or extrinsic causes.

1983-10-01

444

Time-series records of pCO{sub 2} and NO{sub 3} during the OMP Field Program: a final report for DOE Grant DE-FG03-96ER62224  

Energy Technology Data Exchange (ETDEWEB)

The specific goals of this research are to (1) determine daily and seasonal variability of seawater pCO{sub 2} partial pressure of CO{sub 2} and NO{sub 3} in Middle Atlantic Bight (MAB) waters; (2) estimate seasonal CO{sub 2} fluxes between the MAB shelf and the atmosphere; and (3) determine the primary controls of surface seawater pCO{sub 2} in this coastal system. During the first phase of the DOE-OMP (1992-1995) we developed the Submersible Autonomous Moored Instrument for CO{sub 2} (SAMI-CO{sub 2}) which is designed to measure seawater CO{sub 2} on ocean moorings for extended periods.

2000-04-01

445

The radial distribution of the neutron field in the core of Dalat reactor  

International Nuclear Information System (INIS)

Determining the radial distribution of the thermal neutron field in the core of the Dalat reactor was done by the Cu foil activation method. The measured data were fitted by the least square method to determine some physical parameters of the reactor, as follows: 1. Laplacian: B_r"2 = (84.6 +- 5.5)10_-_4/,cm"2. 2. The effective radius: R_e_f_f = (27.6 +- 1.0)cm. 3. The extrapolation distance: #lambda#_r = (8.7 +- 1.0)cm. 4. The unequal coefficient of the effective multiplication: k_r = 1.77 +- 0.11. (author). 3 refs., 4 figs., 1 tab.

1992-01-01

446

The discovery and development of proteomic safety biomarkers for the detection of drug-induced liver toxicity  

British Library Electronic Table of Contents (United Kingdom)

Biomarkers are biometric measurements that provide critical quantitative information about the biological condition of the animal or individual being tested. In drug safety studies, established toxicity biomarkers are used along with other conventional study data to determine dose-limiting organ toxicity, and to define species sensitivity for new chemical entities intended for possible use as human medicines. A continuing goal of drug safety scientists in the pharmaceutical industry is to discover and develop better trans-species biomarkers that can be used to determine target organ toxicities for preclinical species in short-term studies at dose levels that are some multiple of the intended human dose and again later in full development for monitoring clinical trials at lower therapeutic ...

2010-01-01

447

Stem growth habit affects leaf morphology and gas exchange traits in soybean  

British Library Electronic Table of Contents (United Kingdom)

Backgrounds and Aims The stem growth habit, determinate or indeterminate, of soybean, Glycine max, varieties affects various plant morphological and developmental traits. The objective of this study is to identify the effect of stem growth habit in soybean on the stomatal conductance of single leaves in relation to their leaf morphology in order to better understand the ecological and agronomic significance of this plant trait. Methods The stomatal conductance of leaves on the main stem was measured periodically under favourable field conditions to evaluate gmax, defined as the maximum stomatal conductance at full leaf expansion, for four varieties of soybean and their respective determinate or indeterminate near isogenic lines (NILs). Leaf morphological traits including stomatal density, ...

2009-01-01

448

NEW SLAG-BASED CONCRETES  

Environmental Research Database

ObjectivesTo determine the reaction rate of slag during curing and factors affecting reactivity.~%~~%~To measure the rates of chloride ingress into concrete and the extent of chloride binding.~%~~%~To determine conditions for pitting corrosion and the nature of corrosion products.~%~~%~To characterise the reactions in slag-calcium alumina cement hydration and the nature of the products.~%~DescriptionBlast-furnace slag has latent hydraulic properties, giving considerable potential for commercial use in addition to its widespread use as a partial replacement for Portland cement, notably in alkali-activated slag (AAS) and slag-calcium alumina cement (CAC) concretes. Use of AAS concretes is already well-established in China and the former USSR, but their further application is hindered by lack of research into setting, hydration and durability, Slag/CAC blends are new ...

1999-01-09

449

Multiple anthelmintic resistance and the possible contributory factors in Beetal goats in an irrigated area (Pakistan)  

British Library Electronic Table of Contents (United Kingdom)

This paper presents the first report of multiple anthelmintic resistance in the gastrointestinal nematodes of goats and its possible contributory factors in an irrigated area (Pakistan). A total of 18 privately owned Beetal goat flocks were selected in order to determine the anthelmintic resistance against commonly used anthelmintics. Forty to 48 animals from each flock were selected according to their weight and egg count. The three anthelmintics viz., oxfendazole, levamisole and ivermectin, were given to three groups at manufacturer's recommended dose while one group was kept as untreated control. Anthelmintic resistance was determined through faecal egg count reduction and egg hatch tests while assessment of the contributory factors of anthelmintic resistance was measured through the ru...

2010-01-01

450

Multielement analysis of air samples. Determination of iron, zinc, lead, and bromine content by the radionuclide X-ray fluorescence analysis  

Energy Technology Data Exchange (ETDEWEB)

Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A /sup 238/Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed.

1981-01-01

451

Monte Carlo simulations incorporating Mie calculations of light transport in tissue phantoms: Examination of photon sampling volumes for endoscopically compatible fiber optic probes  

Energy Technology Data Exchange (ETDEWEB)

Details of the interaction of photons with tissue phantoms are elucidated using Monte Carlo simulations. In particular, photon sampling volumes and photon pathlengths are determined for a variety of scattering and absorption parameters. The Monte Carlo simulations are specifically designed to model light delivery and collection geometries relevant to clinical applications of optical biopsy techniques. The Monte Carlo simulations assume that light is delivered and collected by two, nearly-adjacent optical fibers and take into account the numerical aperture of the fibers as well as reflectance and refraction at interfaces between different media. To determine the validity of the Monte Carlo simulations for modeling the interactions between the photons and the tissue phantom in these geometries, the simulations were compared to measurements of aqueous suspensions of polystyrene microspheres in the wavelength range 450-750 nm.

1996-04-01

452

Microstructure and fracture toughness of hot pressed zirconia-toughened sialon  

International Nuclear Information System (INIS)

Zirconia-toughened sialon composites have been fabricated using conventional hot-pressing techniques. The fracture toughness and microstructure were determined for CeO_2- and Y_2O_3-stabilized ZrO_2 additives and also as a function of volume percent ZrO_2. The Yttria system showed a linear increase in fracture toughness with increasing volume fraction zirconia content while the ceria-stabilized system exhibited a peak in fracture toughness at 20 vol% ZrO_2 content. The fracture toughness at 800 C was measured and correlated with the microstructure. High-temperature stability was determined and it was found that the deleterious nitride phases of zirconium could be precluded from the microstructure.

453

Method for determining hydrogen mobility as a function of temperature in superconducting niobium cavities  

Energy Technology Data Exchange (ETDEWEB)

A method for determining the mobility of hydrogen as a function of temperature in superconducting niobium cavities comprising: 1) heating a cavity under test to remove free hydrogen; 2) introducing hydrogen-3 gas into the cavity; 3) cooling the cavity to allow absorption of hydrogen-3; and 4) measuring the amount of hydrogen-3 by: a) cooling the cavity to about 4.degree. K while flowing a known and regulated amount of inert carrier gas such as argon or helium into the cavity; b) allowing the cavity to warm at a stable rate from 4.degree. K to room temperature as it leaves the chamber; and c) directing the exit gas to an ion chamber radiation detector.

2008-03-11

454

Mass transfer and sorptive properties of geological samples from the Drigg site  

Energy Technology Data Exchange (ETDEWEB)

This report presents the results of an experimental programme to determine the mass transfer and sorptive properties of selected glacial sand and clays from the Drigg Disposal Site operated by British Nuclear Fuels plc. The hydraulic conductivity of both the sand and clay has been determined and the sensitivity of this parameter to changing water chemistry investigated. The hydrodynamic dispersion properties of the glacial sand were measured in order to aid the interpretation of column sorption experiments. The sorption of strontium and uranium from groundwater onto clay and sand samples has been studied using through-diffusion, column and batch techniques. Employing the batch technique, the effect of a series of humic acid concentrations on distribution ratios for uranium and plutonium has also been investigated. Groundwater and trench leachate were used with both clay and sand. (author).

1990-02-01

455

Low-lying states of {sup 109}Sn from the {sup 106}Cd({alpha},n{gamma}) reaction  

Energy Technology Data Exchange (ETDEWEB)

Measurements of {gamma}-ray, {gamma}{gamma}-coincidence and internal conversion electron spectra from the {sup 106}Cd({alpha},n{gamma}){sup 109}Sn reaction were carried out at 15-20 MeV {alpha}-particle bombarding energies with Ge(HP) {gamma}-ray and superconducting magnetic lens plus Si(Li) electron spectrometers. The energies, relative intensities, internal conversion coefficients and coincidence relations of the {sup 109}Sn transitions were determined, and a more complete, consistent level scheme has been deduced. Spin and parity values have been determined from the internal conversion coefficients, the bombarding-energy dependence of the side-feeding intensities of the states and the available {gamma}-ray angular distribution data. The level scheme was interpreted in the framework of the quasi-particle shell model.

1999-02-01

456

Laser-fluorescence determination of trace uranium in hot spring water, geothermal water and tap water in Xi'an Lishan region  

International Nuclear Information System (INIS)

Using the Laser-Fluorescence technique, an investigation was made, adopting the standard mix method, on trace uranium concentrations in hot spring water and geothermal water from Lishan region, and in tap water from some major cities in Shanxi province. Totally 40 samples from 27 sites were investigated. Measurement showed that the tap water contains around 10"-"6 g/L of uranium, whose concentrations in both hot spring water and geothermal water are 10"-"5 g/L. Most of samples are at normal radioactive background level, some higher contents were determined in a few samples

2002-03-01

457

Kolmogoroff constants at the 1976 ITCE  

Energy Technology Data Exchange (ETDEWEB)

The high-frequency data from 12 sensors at the ITCE 1976 are analyzed to determine the Kolmogoroff constants for velocity, temperature and humidity fluctuations, ..cap alpha../sub u/, ..cap alpha../sub T/, and ..cap alpha../sub q/. The occurrence of aliasing in the spectral analysis in some cases together with the limited response of some sensors at the higher frequencies introduces some uncertainties into the analysis. The Soviet sonic anemometer, fine-wire thermometer and infrared hygrometer and the Australian infrared hygrometer provide the best information, namely that: ..cap alpha../sub u/ = 0.59 +/- 0.01, ..cap alpha../sub T/ = 0.68 +/- 0.02, ..cap alpha../sub q/ = 0.76 +/- 0.03, where the errors quoted refer solely to statistical errors. The other instruments provide general support to these values. The technique of using spectral density measurements to determine eddy fluxes is illustrated.

1982-01-01

458

Interpretation of gamma-scanning data from the ORR demonstration elements  

Energy Technology Data Exchange (ETDEWEB)

The HEU and LEU fuel elements used in the ORR whole-core demonstration were gamma-scanned to determine the axial distribution of the {sup 140}La and {sup 137}Cs activities. Analysis of this data is now complete. From the {sup 140}La activity distributions cycle-averaged powers were determined while the {sup 137}Cs data provided a measure of the final {sup 235}U burnup in the fuel elements. A method for calculating correction factors for activity gradients transverse to the fuel element axis is presented and is applied to the first mixed core used in the demonstration during the gradual transition to an all LEU core. Results based on the gamma-scanning of the LEU fuel followers are also presented. Improved burnup calculations against which the experimental results are to be compared are now in progress. 7 refs., 21 figs., 3 tabs.

1989-01-01

459

Heat loss from an open cavity  

Energy Technology Data Exchange (ETDEWEB)

Cavity type receivers are used extensively in concentrating solar thermal energy collecting systems. The Solar Total Energy Project (STEP) in Shenandoah, Georgia is a large scale field test for the collection of solar thermal energy. The STEP experiment consists of a large field array of solar collectors used to supplement the process steam, cooling and other electrical power requirements of an adjacent knitwear manufacturing facility. The purpose of the tests, conducted for this study, was to isolate and quantify the radiative, conductive, and convective components of total heat loss, and to determine the effects of operating temperature, receiver angle, and aperture size on cavity heat loss. An analytical model for radiative heat loss was developed and compared with two other methods used to determine radiative heat loss. A proposed convective heat loss correlation, including effects of aperture size, receiver operating temperature, and ...

1995-12-01

460

Fuel element powers, STVU masses, and burnups from gamma-scanning data: Preliminary analysis of irradiated ORR (Oak Ridge Research Reactor) LEU fuel elements  

Energy Technology Data Exchange (ETDEWEB)

Fuel elements used in the ORR whole-core LEU fuel demonstration have been gamma-scanned to determine axial distributions of UZLa and TXCs fission product activities. This data has been analyzed to determine cycle-averaged fuel element powers, residual STVU masses, and burnups of discharged fuel elements. Methods used to analyze the data are discussed and results are presented for the LEU fuel elements. Measured and calculates fuel element powers agree to within 5%, residual STVU masses to within 2%, and burnups to within 3%. These results are somewhat preliminary and await improved burnup calculations and independent calibration data to be based on the destructive analyses of a number of irradiated fuel elements. 4 refs., 7 figs., 3 tabs.

1988-01-01

461

Estimation of "1"3"7Cs body burden in Japanese, 2  

International Nuclear Information System (INIS)

The biological half-life of "1"3"7Cs in the total body of human subjects was determined in 23 individuals of Japanese male adult in their normal works by measuring amount of "1"3"7Cs in both their total body and daily urine in the same period. For the group, the value was determined by averaging the half-lives for individuals, by comparing the mean body burden and the mean daily urinary excretion, or by applying a curve fitting method to the body burden estimate. The biological half-life averaged 86 days, ranging from 50 to 161 days. The averages of the biological half-lives for the group were 83, 87 and 82 days in the different periods of observation. By the curve fitting method, 85 days was found for the group. The biological half-life for the individuals depended on both body weight and age, to a lesser extent, of the subjects. (author).

462

Diesel exhaust inhalation induces heat shock protein 70 expression in vivo  

British Library Electronic Table of Contents (United Kingdom)

Exposure to urban air pollution is an independent risk factor for increased cardiovascular diseases. Heat shock protein 70 (HSP70) has been implicated in the pathogenesis of vascular dysfunction and cardiovascular diseases. This study has been designed to determine whether inhalation of urban air induces HSP70 expression in the lung and blood as well as the association of HSP70 and air pollution-induced vascular dysfunction. Apolipoprotein E (Apo-E) deficient mice were exposed to diesel exhaust (DE) either acutely (3 days, 200 or 400 g/m3 for 6 h/day) or chronically (7 weeks, 200 or 400 g/m3 for 6 h/day). HSP70 was measured in the lung using immunohistochemistry, and in the plasma by ELISA. Abdominal aorta rings were used to determine vascular functional responses. Chronic DE-exposure incr...

2011-01-01

463

Determining concentration distribution of admixture from count ratemeter response in continuous analyses  

International Nuclear Information System (INIS)

A comparison is made of the response of a count ratemeter and a pulse counter using the mathematical tool of the Z transform. Transform Z is used for the solution of the convolution integral interpreting the analog output of the count ratemeter used for recording characteristic radiation, excited in the moving beam. The comparison of count rates obtained by the count ratemeter during continuous analysis and the pulse counter during discontinuous measurement gave the transfer function of the count ratemeter in the actual range of count rate. Also discussed is the use of the transfer function for localizing concentration changes in the sample. The use of the described method is demonstrated on the determination of the tin content in tungsten using continuous radionuclide X-ray fluorescence analysis. (B.S.).

1983-01-01

464

Determining a bisection bandwidth for a multi-node data communications network  

Energy Technology Data Exchange (ETDEWEB)

Methods, systems, and products are disclosed for determining a bisection bandwidth for a multi-node data communications network that include: partitioning nodes in the network into a first sub-network and a second sub-network in dependence upon a topology of the network; sending, by each node in the first sub-network to a destination node in the second sub-network, a first message having a predetermined message size; receiving, by each node in the first sub-network from a source node in the second sub-network, a second message; measuring, by each node in the first sub-network, the elapsed communications time between the sending of the first message and the receiving of the second message; selecting the longest elapsed communications time; and calculating the bisection bandwidth for the network in dependence upon the number of the nodes in the first sub-network, the predetermined message size of the first test message, and the longest elapsed ...

2010-01-26

465

Determination of the hydrogen content of a-Si films by infrared spectroscopy and 25 MeV #alpha#-particle elastic scattering  

International Nuclear Information System (INIS)

The simultaneous hydrogen and silicon atom densities in amorphous silicon, a-Si, films prepared by the glow discharge technique have been measured by 25 MeV #alpha#-particle elastic scattering. Integrated band intensities for the silicon-hydrogen stretching modes, #omega#_1sup(s) and #omega#_2sup(s) in the region 1800 to 2200 cm"-"1 were determined for the same freely supported films. A similar analysis has been carried out for the bands observed at 890, 840 and 640 cm"-_1. Effective oscillator strengths for the #omega#_1sup(s) and #omega#_2sup(s) modes in a-Si films have been estimated and compared with the current theories on the effect of the silicon matrix on the infrared absorption characteristics. (author).

466

Decay of very neutron-rich Mn nuclides and vanishing of the N=40 subshell closure in {sup 66}Fe  

Science.gov (United States)

The use of chemically selective laser ionization combined with beta-delayed neutron counting at ISOLDE has permitted identification and half-life measurements for {sup 61}Mn up through {sup 69}Mn. The 14(4)-ms half life for {sup 69}Mn is one of the shortest determined for any nuclide beyond the sd shell. Gamma-ray singles and coincidence spectra have been determined for the decays of {sup 64,66}Mn to levels of {sup 64,66}Fe, revealing strong deformation and vanishing of the N=40 subshell in the Fe isotopes. {copyright} {ital 1998 American Institute of Physics.}

1998-12-01

467

Decay of very neutron-rich Mn nuclides and vanishing of the N=40 subshell closure in "6"6Fe  

International Nuclear Information System (INIS)

The use of chemically selective laser ionization combined with beta-delayed neutron counting at ISOLDE has permitted identification and half-life measurements for "6"1Mn up through "6"9Mn. The 14(4)-ms half life for "6"9Mn is one of the shortest determined for any nuclide beyond the sd shell. Gamma-ray singles and coincidence spectra have been determined for the decays of "6"4","6"6Mn to levels of "6"4","6"6Fe, revealing strong deformation and vanishing of the N=40 subshell in the Fe isotopes.

1998-12-21

468

Crystal electric field in RAgSb_2 (R = Ho, Er, Tm) intermetallic compounds  

International Nuclear Information System (INIS)

The magnetic scattering spectra of RAgSb_2 (R = Ho, Er, Tm) intermetallic compounds are measured and their crystal electric field parameters are determined using inelastic neutron scattering. It is revealed that the ground state is a nonmagnetic singlet for the HoAgSb_2 compound, a Kramers doublet with a strongly anisotropic g factor for the ErAgSb_2 compound, and a quasi-doublet (random doublet) characterized by an extremely anisotropic g factor for the TmAgSb_2 compound. The exchange interaction is estimated in the molecular field approximation. The magnetic properties of the RAgSb_2 compounds are analyzed in terms of the energy level schemes and eigenfunctions determined in this study. The calculated anisotropic magnetic susceptibilities for all compounds are in good agreement with the experimental data obtained for single crystals.

2007-05-01

469

Cosmological Questions for the European Southern Observatory Very Large Telescope  

CERN Document Server

The next decade promises an observational revolution which will change cosmology forever. The precise measurement of the angular anisotropy of the cosmic microwave background should specify to a few percent all of the parameters of the cosmological model which effect astrophysics. The growth of structure will then be determined (but not yet observed) until gravitational collapse becomes highly non-linear and stars, galaxies and active galactic nuclei (AGN) form. These processes are hard to model with basic physics because they are complex and allow a rich variety of expression. Instead observations will determine when the first stars and quasars formed, and how and when galaxies assembled. If we can reconcile the numerous contradictions which characterize the subject today, cosmology will become a mature subject, founded on the agreement between detailed, inclusive and realistic models, which make precise predictions, and ...

1996-01-01

470

Application of photoelectrochemistry and impedance measurements to the study of passive films on AISI 304 stainless steel  

International Nuclear Information System (INIS)

In this work passive films formed in AISI 304 stainless steel were envisaged as semiconductors and studied by means of photoelectrochemistry and Mott-Schottky plots. The passive films were potentiostatically formed at different potentials (0.2-0.8V) in a basic borate/boric acid solution without and with addition of NaCl (0.5 and 1g/l) and at various temperatures in the range 8-60"oC. The influence of these parameters on the photocurrent, quantum efficiency, bandgap energy and density of charge carriers was determined. The results show that the experimental conditions at which the films are formed influence the semiconductive properties of the film, which seem to be related to the higher or lower stability of the film. An Arrhenius type of relationship was also found between the density of charge carriers and temperature, leading to the determination of an activation energy. (author) 13 refs., 7 figs.

1988-07-01

471

A TLD powder dosimetry measurement system for physical models of reference man  

International Nuclear Information System (INIS)

A tissue-equivalent dosimetry system has been developed for use in absorbed dose determinations with physical models of Reference Man. The dosimeter used was a thermo-luminescent dosimeter (TLD) powder which was mixed with a 'tissue-equivalent' material and modeled to closely approximate an organ's geometry and absorption properties. A separation procedure was developed by which the TLD powder was washed and the 'tissue-equivalent' material, a wax, was dissolved and extracted following the irradiation of the model. The procedure was tested to determine losses of powder, homogeneity of the powder's distribution throughout the wax, the effects of the separation procedure upon the powder and the statistical behavior of the procedure. The results of these tests established the feasibility of the procedure. A full-scale model of the pancreas was tested and the results supported the validity of the technique. (author)

1978-12-01

472

Tar protocol. Development of a standard method for the measurement of organic contaminants ('Tar') in biomass producer gases  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the history and objectives of the development of a standard method for the measurement of organic contaminants in biomass producer gases. Recently, a project with that title has started in the European 5{sup th} Framework Programme. The structure of this project with acronym 'Tar Protocol' is also described in this paper. The project is performed by 17 partners and continues earlier work initiated by IEA (International Energy Agency), DoE (Department of Energy) and EU (European Union) in 1998. The project aims to combine two draft Protocols that resulted from this earlier work. The Tar Protocol will be developed for accurate measurement of organic contaminants ('tars') over a large range of concentrations (1 mg/Nm{sup 3} to 100 g/Nm{sup 3}) and conditions (0 - 900 deg C; 0.9 - 60 bars). Besides, a particulate concentration will be determined too. Together with the ...

2000-06-01

473

Properly synchronized measurements of droplet sizes for high-pressure intermittent coal-water slurry fuel sprays  

Energy Technology Data Exchange (ETDEWEB)

Experiments were completed to study intermittent coal-water slurry (CWS) fuel sprays injected from an electronically-controlled accumulator injector system. A new synchronization technique was developed using the light extinction signal as a triggering source for the data taking initiation with a laser diffraction particle analyzing (LDPA) technique. This technique allowed measurement of SMDs near the spray tip where the light extinction was low and the data were free from the multiscattering bias. Coal-water slurry fuel with 50% coal loading in mass containing 5 {mu}m mass median diameter coal particulates was considered. A correlation of the SMD with the injection conditions was determined which should show a satisfactory agreement with the measured SMD data. The spray SMD showed an increase with the distance of the axial measurement location and with the ambient gas density, and showed a decrease ...

1993-12-31

474

Principles of the measurement of residual stress by neutron diffraction  

Energy Technology Data Exchange (ETDEWEB)

The presence of residual stresses in engineering components can significantly affect their load carrying capacity and resistance to fracture. In order to quantify their effect it is necessary to know their magnitude and distribution. Neutron diffraction is the most suitable method of obtaining these stresses non-destructively in the interior of components. In this paper the principles of the technique are described. A monochromatic beam of neutrons, or time of flight measurements, can be employed. In each case, components of strain are determined directly from changes in the lattice spacings between crystals. Residual stresses can then be calculated from these strains. The experimental procedures for making the measurements are described and precautions for achieving reliable results discussed. These include choice of crystal planes on which to make measurements, extent of masking needed to identify a ...

1996-11-01

475

Measurements of fluctuations in the flux of runaway electrons to the PLT limiter  

Energy Technology Data Exchange (ETDEWEB)

Fluctuations in the flux of runaway electrons to the limiter have been measured during many PLT discharges. Oscillations at 60, 120, and 720 Hz are driven by variations in the vertical magnetic field which moves the plasma major radius. Fluctuations are seen in the range of 2 ..-->.. 20 kHz due to MHD magnetic islands which extend to the plasma surface. A continuous spectrum of fluctuations is observed up to 200 kHz which correlates with drift-wave turbulence. The magnitude of the driven fluctuations can be used to measure transport properties of the runaway electrons. The amplitude of electron motion due to the MHD and drift-wave oscillations, and hence a measure of the radial size of the instability, can be determined as a function of frequency. The slope of the frequency power spectrum of the drift-wave-induced fluctuations steepens with increasing runaway electron drift orbit displacement during ...

1982-07-01

476

Measurement of in-situ stress in salt and rock using NQR techniques  

Energy Technology Data Exchange (ETDEWEB)

A discussion of how stress and strain affect the quantities which can be measured in an NQR experiment shows that, for stresses of the magnitude to be expected at depths up to about 10,000 feet, quadrupole coupling constants will fall in the range of 1 to 10 kHz for both the sodium and chloride ions in NaCl. The most promising system involves pulsed nuclear double resonance detection; and alterative is to observe the quadrupolar splitting of the NMR signal. Choices to be made in the measurement and mapping techniques are discussed. The well-known perturbation of the homogenous stress field in the neighborhood of a borehole is shown to be advantageous from the point of view of obtaining directional information on the stress. Construction and operation of a borehole stress sensor are considered. The NQR technique seems feasible for measuring the magnitude and direction of underground stress with a resolution of about 25 psi, ...

1980-12-01

477

Masses of Neutron Stars in High-Mass X-ray Binaries with Optical Astrometry  

CERN Document Server

Determining the type of matter that is inside a neutron star (NS) has been a long-standing goal of astrophysics. Despite this, most of the NS equations of state (EOS) that predict maximum masses in the range 1.4-2.8 solar masses are still viable. Most of the precise NS mass measurements that have been made to date show values close to 1.4 solar masses, but a reliable measurement of an over-massive NS would constrain the EOS possibilities. Here, we investigate how optical astrometry at the microarcsecond level can be used to map out the orbits of High-Mass X-ray Binaries (HMXBs), leading to tight constraints on NS masses. While previous studies by Unwin and co-workers and Tomsick and co-workers discuss the fact that the future Space Interferometry Mission should be capable of making such measurements, the current work describes detailed simulations for 6 HMXB systems, including predicted constraints on ...

2010-01-01

478

Los Alamos second-generation system for passive and active neutron assays of drum-size containers  

International Nuclear Information System (INIS)

We describe in a comprehensive fashion the Los Alamos second-generation system for passive and active neutron assays of drum-size containers. The developmental history of this 7-year project is presented with emphasis on the pulsed active neutron technique (differential dieaway), which has achieved milligram levels of assay sensitivity for both plutonium and uranium wastes. We describe in detail the matrix effects for both passive and active neutron assays. We present in a thorough fashion our novel approach to achieving comprehensive corrections for these matrix effects using measurements made during the assays. We develop a matrix correction formalism based on separate neutron absorption and moderator indices determined from these measurements. These are presented as a series of analytic functions fitted to the data. Absolute calibrations and calibration standards are discussed, as is a practical means (pink drum ...

1972-09-17

479

Influence of nutrition on ovulation rate and testicular growth of Merino sheep  

International Nuclear Information System (INIS)

The effect of nutrition on reproductive performance was studied in a series of experiments using two models. Increased supply of nutrients was based on feeding lupin grain as a supplement and measurements of testicular growth or ovulation rates were used to measure reproductive characteristics. Purified sources of protein and energy were provided to determine the macronutrient(s), supplied with lupin feeding, responsible for initiating increases in testicular growth and ovulation rate. Increases in both of these parameters were closely related to the supply of additional energy but not protein. The production of acetate and glucose resulting from supplementary feeding with 750 g lupins/d was measured using infusions of "1"4C tracers. Subsequently, infusions of glucose and acetate (individually and in combination) were found to produce similar increases in ovulation rate to those ...

1987-03-01

480

Electron flow in the SABRE linear induction adder in positive polarity  

International Nuclear Information System (INIS)

In a positive polarity induction adder each of the induction cavities is a cathode, which emits electrons at a unique potential. These broad spectrum electrons strongly affect Magnetically Insulated Transmission Line (MITL) behavior. Electron flow decreases the cavity-to-MITL coupling efficiency, and reduces the power transport efficiency along the system. Also, the operating impedance of the MITL is lowered, reducing the diode impedance required for good coupling and good total system power efficiency. It is therefore imperative to understand the details of MITL electron flow. In previous work, measurement of MITL electron flow for a twenty-stage linear induction adder (Hermes III), operated in positive polarity, was compared with simulations. There was qualitative agreement, but some differences were noted. For example, measured electron flow in the first cavities was greater than in the simulations. The authors have extended the work on this ...

1993-05-17

481

Comparison of methods to measure the rate of neutral free radical production by photo-deionization of negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Two measurement methods to determine the rate of neutral free radical production by the photo-deionization of negative ion beams (PDINIB) are introduced. These methods, namely, photoelectron-current measurement by low-frequency electro-modulation probe (PMMP) and measurement of decrease in the negative-ion beam current (DNIC) were employed to evaluate the production rate in a trial surface-processing apparatus developed in the author's laboratory utilizing a steady-flux refined beam of neutral free radicals (RBNR) produced by the PDINIB procedure. A {sup 63}Cu{sup -} negative ion beam of kinetic energy E{sub i} varied up to 15 keV was irradiated with a 514.5 nm visible light beam from a 25 W CW Ar{sup +} ion laser. The detection limit of the production rate by the PMMP setup was as high as 6 x 10{sup 9} s{sup -1} under the condition that E{sub i}=15 keV, the negative-ion beam current I{sub i}=4 ...

2003-05-01

482

A water calorimeter for high energy x-rays and electrons  

CERN Document Server

The current primary standards at NPL for the measurement of absorbed dose to water in high energy photon and electron beams are graphite calorimeters. However, the quantity of interest in radiation dosimetry is absorbed dose to water. Therefore, a new absorbed dose to water standard based on water calorimetry has been developed for use in high energy photon and electron beams. The calorimeter operates at 4 deg C, with temperature control being provided by liquid cooling. The sealed glass inner vessel of the calorimeter was designed to minimise the effect of non-water materials on the measurement of absorbed dose. The temperature sensing thermistor probes were designed and constructed so that glass is the only material in contact with high purity water inside the vessel. Initial measurements of absorbed dose to water made in 6, 10, and 19 MV photons, and 16 MeV electrons agreed, within the measurement ...

2000-01-01

483

Subcriticality measurements for two coupled uranyl nitrate solution tanks using /sup 252/Cf-source-driven neutron noise analysis methods  

Energy Technology Data Exchange (ETDEWEB)

The subcriticality of two interacting solution tanks was determined using /sup 252/Cf-source-driven neutron noise analysis methods. These experiments were the first test of this method for an interacting system with materials (in this case, uranyl nitrate) typical of nuclear materials in processing plants. The experiments were performed to test the conclusions from previous interaction experiments with uranium metal discs for a fissile system with moderation, and to provide data to test theoretical models for coupled systems. The uranium metal experiments showed that the subcritical neutron multiplication factor, k/sub eff/, could be determined using point kinetics without any correction for spatial effects from measurements with the source and detectors located adjacent to the same cylinder, whereas for source-detector configurations with either the source and/or detectors adjacent to different cylinders, a model which ...

1986-01-01

484

On the calculation of scattered fields by 3-D structure in the time-domain electromagnetic (TDEM) method; Jikan ryoiki denjiho ni okeru sanjigen kozo kara no sanranba no keisan ni tsuite  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the calculation method of 3-D underground structures in TDME method which measures only field components. Recently, FDTD method was developed as calculation method in time domain difference calculus, and the forward analysis accuracy of 3-D fields was rapidly improved. The survey results using a large-scale loop (600m{times}360m) were numerically analyzed by FDTD method. 16 measuring lines were prepared in both X and Y directions, and measuring points were prepared on intersection points of the measuring lines. Since signal current is staircase one, step and impulse responses of the ground were determined by calculating magnetic field and its time differentiation. The rectangular body (120m{times}120m{times}100m) of 0.2S/m in conductivity (5 ohm m in resistivity) was installed 160m under the ground as 3-D resistivity anomaly. The ground of 0.01S/m (100 ohm m) ...

1996-10-01

485

Evaluation of methods to measure surface level in waste storage tanks: Second test sequence  

Energy Technology Data Exchange (ETDEWEB)

This report describes the results of a program conducted at the Pacific Northwest Laboratory (PNL) and Westinghouse Hanford Company (WHC) to identify alternative methods to measure the surface level in the waste tanks. This program examined commercially available devices for measuring the distance to a target. This is a continuation of a program started in FY93. In the first test sequence, tests were performed.on five devices to determine their applicability to measure the surface level in the waste tanks. The devices were the Enraf-Nonius{trademark} Model 872 Radar Gauge, the Enraf-Nonius{trademark} Model 854 Advanced Technology Gauge (ATG), the Stanley Tool Laser Measuring Device, the Robertshaw Inven-Tel{reg_sign} Precision Level Gauge, and the Micro Switch Model 942 Acoustic Sensor. In addition, discussions were held with several manufacturer representatives regarding other ...

1993-09-01

486

Current Status on Stress Diagnostic Kit and Detection Technology  

Energy Technology Data Exchange (ETDEWEB)

The accurate measurement of a stress level is one of the most important issues in a stress diagnosis and its measurement could be of great value in clinical medicine. Stress has a potent effect on the spirit and physical condition of an individual. There are various methods available for its measurement. Some of the commonly used techniques for the diagnosis of a stress level include analysis of the body fluids, questionnaire assessments, psychophysiological evaluations and by determining heart rate variability (HRV) of subjects. However, the existing diagnostic methods have several defects like, a low sensitivity, inaccuracy and long of operation time. In this report, we present a diagnostic technology to detect a stress level which is the origin of various diseases. This method can be of great help in providing an early diagnosis through a biosensor and might play a vital role in preventing diseases ...

2008-06-15

487

Upper limb dysfunction following selective neck dissection: A retrospective questionnaire study  

British Library Electronic Table of Contents (United Kingdom)

Background. To determine total upper limb function following selective neck dissection over a mean follow-up of 1.6 years. Methods. A retrospective questionnaire study in a tertiary head and neck surgical unit. One hundred forty-eight patients who underwent selective neck dissection for head and neck cancer from January 2000 to December 2005 were invited to participate. The main outcome measure was ipsilateral upper limb dysfunction as measured by the Disability of Arm, Shoulder and Hand (DASH) questionnaire. Results. Sixty-five patients responded to the invitation to join the study from 148 invited. Despite accessory nerve conserving surgery for all the selective neck dissections studied, 23% reported no upper limb dysfunction, 54% reported mild upper limb dysfunction, 15% reported modera...

2009-01-01

488

Prognostic value of plasma B-type natriuretic peptide in patients with severe cardiotoxic drug poisoning  

British Library Electronic Table of Contents (United Kingdom)

Background/Objectives: Cardiotoxic drug poisoning can lead to severe cardiac shock (CS) and death. B-type natriuretic peptide (BNP) is a well-established diagnostic and prognostic marker in heart failure but has never been assessed in patients with cardiotoxic drug poisoning. The aim of the study was to determine whether BNP could be useful for early stratification of patients admitted to intensive care unit. Methods: 30 consecutive patients experiencing shock and cardiotoxic drug exposure were enrolled in a prospective monocentric study and underwent at least two BNP measurements within the first 24 h after admission. Results: While BNP values on admission were poorly informative, subsequent BNP measurements (11 +- 6 h after admission) were significantly increased in patients with CS comp...

2011-01-01

489

Problems of air pollution monitoring  

Energy Technology Data Exchange (ETDEWEB)

The development of the monitoring network for background measurements of air pollution in the USSR is noted. The use of paired stations, to aid in locating permanent sites as well as for determining the local component of background air pollution, is described. Thermoelectric actionometers with five glass filters are used to measure Shupp's turbidity coefficient for estimating extinction of solar radiation due to aerosols. Sampling and chemical analysis of precipitation uses methods developed during the International Geophysical Year. An intercomparison of meteorological instruments was carried out in the USSR in 1973 and 1978. The most stable actinometer was the Linke-Foisner device. Chemical analyses of precipitation made since 1958 in the USSR show increases in air pollution levels only in particular areas.

1980-01-01

490

Normalized noise power spectrum of full field digital mammography detector system  

International Nuclear Information System (INIS)

Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)

491

Normalized Noise Power Spectrum of Full Field Digital Mammography System  

International Nuclear Information System (INIS)

A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.

2010-01-05

492

Measurements of environmental policy for air pollution abatement. Umweltpolitische Massnahmen zur Luftreinhaltung; Kosten-Nutzen-Analyse  

Energy Technology Data Exchange (ETDEWEB)

The first part of the study goes into the determination of efficient strategies for the reduction of air pollutants. The developed method is not only derived theoretically but is tested with the concrete example of emissions sources of a German state. The second part goes into the question what the government can do in order to attain that air pollution abatement measures recognized as being efficient will be put into practice. As market economy mechanisms have advantages over central state planning in the allocation of economic resources the question arises if not also for environmental protection market economy tools may contribute to an improvement of the efficiency of air pollution abatement. Therefore the suitability of different tools of environmental policy for the realization of efficient air pollution abatement is investigated and evaluated. This is again not done abstractly but with existing emission sources. (orig./HSCH). 32 figs., ...

1993-01-01

493

Measurement of beta-decay half-lives of short-lived nuclei with Spectrum Multi-Scaler (SMS)  

Energy Technology Data Exchange (ETDEWEB)

The half-lives of short-lived nuclei produced by 14 MeV or thermal neutron bombardments were measured with a Ge detector, a Spectrum Multi-Scaler (Laboratory Equipment Corporation SMS-48) and a High-Rate Spectroscopy Amplifier (EG and G ORTEC Model 973) in the multi-scaling mode. The corrections for pile-up and dead-time losses were performed by applying source and pulser methods. The half-lives of {sup 91m}Mo, {sup 97m}Nb, {sup 138}Cs, {sup 139}Ba, {sup 174}Tm and {sup 203m}Pb were determined with accuracy of 0.22-0.6% and the accuracy has been much improved. (author)

1996-03-01

494

Market based pollution abatement measures and creation of internal environmental diseconomies  

Energy Technology Data Exchange (ETDEWEB)

New market based approaches are becoming increasingly important as instruments of environmental policy. The two main market approaches, i.e., transferable pollution permits (experimented in America), and 'green' energy surcharges (European philosophy), are described and discussed. An analysis of information on their state of implementation shows that, in the case of the former method, the greatest sources of difficulty arise in the determination of acceptable ceiling levels of emissions, in the distribution of permits among the various polluting firms, and in the legality of granting rights to pollute. Instead, the European experience has evidenced that energy surcharges motivated by environmental policy cannot have an appreciable positive impact on consumers or the economic system in general unless they are accompanied by well defined measures geared towards the promotion or creation of alternative solutions such as to ...

1991-09-01

495

GPS impact on geodesy  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to check up a GPS (global positioning system) impact on scientific research activities of the Geodetic Society of Japan. First, it is mentioned that the conventional geoid-based concept of 'gravity anomaly' should be changed to a new definition, according to the GPS-determined ellipsoidal height system. Secondly, the results of many experiments, which have been made to monitor ocean-plate motions relative to the Japanese island-arcs, demonstrate that GPS is a powerful tool for obtaining temporal changes in horizontal displacement induced by the plate motion. Therefore, it is suggested that terrestrial measurements, such as triangulation and long-range leveling, would be replaced by GPS measurements in near future. Moreover, it is pointed out that GPS geodesy should play an important role in monitoring secular sea level trend due to global warming of the atmosphere and ocean. 19 ...

1992-12-25

496

Estimation of plasma density by surface plasmons for surface-wave plasmas  

International Nuclear Information System (INIS)

An estimation method of plasma density based on surface plasmons theory for surface-wave plasmas is proposed. The number of standing-wave is obtained directly from the discharge image, and the propagation constant is calculated with the trim size of the apparatus in this methods, then plasma density can be determined with the value of 9.1 x 1017 m-3. Plasma density is measured using a Langmuir probe, the value is 8.1 x 1017 m-3 which is very close to the predicted value of surface plasmons theory. Numerical simulation is used to check the number of standing-wave by the finite-difference time-domain (FDTD) method also. All results are compatible both of theoretical analysis and experimental measurement. (authors)

2008-12-01

497

Circumsolar radiation telescope  

Energy Technology Data Exchange (ETDEWEB)

A circumsolar telescope for determining the flux of energy from the sun and from the circumsolar region as a function of angle, wavelength, and atmospheric conditions is presented. The telescope system consists of a specially designed scanning telescope, an electronic control and recording system and some auxiliary equipment. The detector is a pyroelectric crystal, a type of thermal detector, thus the fundamental measurement is relatively wavelength insensitive. The telescope is designed to provide data for all weather conditions during which a concentrating solar energy system would be operating. Analyses show that for a clear blue sky, the amount of radiation coming directly from the sun, while for a sky with thin clouds or haze, the circumsolar radiation is some 25% of the direct solar radiation. Under such conditions a measure of the circumsolar radiation is necessary for an accurate prediction of the performance of a ...

1980-01-01