A magnetically levitated electrode ionization chamber of the noncontact measurement type
Energy Technology Data Exchange (ETDEWEB)
A new type of ionization chamber with levitated electrode has been developed. In this ionization chamber, an ion-collection electrode levitates in the air without getting any physical support from the insulator. The electrode is charged by an electrostatic charger without physical contact. The charge of the electrode is read out at a Faraday cage periodically at a given time interval without physical contact. Because its electrode levitates, the ionization chamber produces no background current caused by leaks or piezo current. In addition, as the charging of its electrode and the read-out of its charge are carried out without physical contact, no irregular charge or contact potential difference due to the chattering between electrode and contact point occurs. Through experiments, it was found that this ionization ...
2002-04-01
Energy Technology Data Exchange (ETDEWEB)
A custom-built graphite-coated transmission ionization chamber is compared to the VacuDAP 2001 (VacuTec, Dresden, Germany), which has transparent conductive electrodes. A study was made of the dependence of response on x-ray tube potential for both types of chamber under identical conditions of exposure using over-table and under-table x-ray tubes. Since the calibration factor is the dose-area product of the radiation incident on the patient per chamber reading, it depends on the intrinsic response of the chamber as well as the effect of material in the beam between the x-ray tube and patient. Differences of about 20% were measured between the intrinsic and the over-table calibration factors and between the over-table and the under-table calibration factors for both chambers. The VacuDAP display is specifically calibrated for the over-table condition and would ...
2000-03-01
A Fast Ionization Chamber for Fission Cross-Section Measurements at n(_)TOF
International Nuclear Information System (INIS)
An ionization chamber with fast timing properties was built at CERN for measuring fission cross-sections of minor actinides at the n(_)TOF neutron beam. The design of this new chamber and of the front-end electronics was optimized to match the innovative features of the n(_)TOF facility, in particular the high instantaneous neutron flux and low background. For the most radioactive isotopes, a special version of the chamber, designed according to the ISO2919 standards, was built in order to comply with the radioprotection requirements at CERN. The detector and front-end electronics are here described, together with the simulated and measured response to fission fragments and #alpha#-particles. The performances of the chamber during the first measurement campaign at n(_)TOF are presented, focusing in particular on the fast time response, the good background rejection capability, ...
2008-09-01
Energy Technology Data Exchange (ETDEWEB)
A new method named 'Bragg curve spectroscopy', based on the Bragg curve of the heavy ion being stopped in a gaseous ionization chamber, has been developed for identifying the particle and measuring its energy. The design of such a chamber and the experience obtained with chamber using various kinds of fast heavy ions are described. In conclusion, several problems to be solved in this method are pointed out.
1982-05-01
International Nuclear Information System (INIS)
A new method named 'Bragg curve spectroscopy', based on the Bragg curve of the heavy ion being stopped in a gaseous ionization chamber, has been developed for identifying the particle and measuring its energy. The design of such a chamber and the experience obtained with chamber using various kinds of fast heavy ions are described. In conclusion, several problems to be solved in this method are pointed out. (orig.).
Results from a Bragg Curve Spectrometer
Energy Technology Data Exchange (ETDEWEB)
The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. We have constructed and tested several versions of the BCS. The results are described.
1984-01-01
Results from a Bragg Curve Spectrometer
International Nuclear Information System (INIS)
The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. We have constructed and tested several versions of the BCS. The results are described.
1984-10-22
Bragg-curve spectroscopy detector
Energy Technology Data Exchange (ETDEWEB)
In an ionization chamber with the electric field parallel to the particle trajectories, the time dependence of the anode signal contains all the information about the energy and the nuclear charge of the ionizing particle. By proper pulse shaping with a long and a short time constant the total ionization charge and the ionization charge integrated around the Bragg maximum, respectively, can be obtained. The former signal is proportional to the total energy, whereas the latter allows the nuclear charge to be deduced directly. An energy resolution of 0.4% and a Z resolution ..delta..Z/Z = 1/82 was achieved for 130 MeV /sup 32/S ions and argon-methane as the stopping medium.
1982-02-01
Development of ambient sampling chemi/chemical ion source with dielectric barrier discharge
British Library Electronic Table of Contents (United Kingdom)
The development of a new configuration of chemical ionization (CI)-based ion source is presented. The ambient air containing the gaseous sample is sniffed into an enclosed ionization chamber which is of sub-ambient pressure, and is subsequently mixed with metastable species in front of the ion inlet of the mass spectrometer. Metastable helium atoms (He*) are used in this study as the primary ionizing agents and are generated from a dielectric barrier discharge (DBD) source. The DBD is powered by an AC high-voltage supply and the configuration of the electrodes is in such a way that the generated plasma is confined within the discharge tube and is not extended into the ionization chamber. The construction of the ion source is simple, and volatile compounds released from the bulky sample can...
2010-01-01
International Nuclear Information System (INIS)
When exposure-calibrated ionization chambers are used to calibrate megavoltage X-ray and electron beam therapy machines, the calibration factor can be divided into a chamber-dependent and a chamber-independent component. Until recently, only the chamber-independent part, which has been derived theoretically, has been used; the chamber-dependent component has been ignored. Recent experimental and theoretical considerations, however, have indicated that the dependent component must be taken into account and can affect the calibration by as much as 4%. The calibration can change due to (i) the thickness of the chamber wall, (ii) the chamber wall composition, i.e. whether the chamber is constructed of air-equivalent material, or tissue- or water-equivalent material, and (iii) the size of the ...
MAGIC - Multi Anode Gas Ionization Chamber
Energy Technology Data Exchange (ETDEWEB)
A novel approach to the Bragg curve spectroscopy is utilized to construct a charged particle detector which makes fragment elemental identification and energy measurement possible. The advantage of the construction includes good timing and spectroscopic properties with a very low energy threshold. ((orig.))
1994-12-01
Bragg curves of fission fragments in gases
Energy Technology Data Exchange (ETDEWEB)
An unexpectedly high probability of collisions between the fission particles and the atoms in an ionization chamber along the entire particle track causes a strong fluctuation of the shapes of the Bragg curves. This fluctuation imposes an upper limit of the charge resolution ..delta..Z/Z which can be achieved.
1986-03-01
Energy Technology Data Exchange (ETDEWEB)
A detector head for in situ inspection of irradiated nuclear fuel assemblies submerged in a water-filled nuclear fuel storage pond. The detector head includes two parallel arms which extend from a housing and which are spaced apart so as to be positionable on opposite sides of a submerged fuel assembly. Each arm includes an ionization chamber and two fission chambers. One fission chamber in each arm is enclosed in a cadmium shield and the other fission chamber is unshielded. The ratio of the outputs of the shielded and unshielded fission chambers is used to determine the boron content of the pond water. Correcting for the boron content, the neutron flux and gamma ray intensity are then used to verify the declared exposure, cooling time and fissile material content of the irradiated fuel assembly.
1985-04-09
Results from a Bragg Curve Spectrometer
International Nuclear Information System (INIS)
The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is proportional to the specific ionization along the track. The preamp output is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. Several versions of the BCS have been constructed and tested. Test results, detector characteristics and some design problems are discussed.
1984-10-01
The high-sensitive magnetic levitated electrode ionization chamber of the noncontacting type
Energy Technology Data Exchange (ETDEWEB)
There are two types of ionization chamber using magnetically levitated electrode: one is that by Tanaka et al. and the other, by authors'. The latter lacks the sensitivity relative to the former and thereby to solve the problem, authors made an improvement so that the electrode charge could be readout by noncontact after the leviated electrode was electrified by noncontact for an interval. This new type ionization chamber made it possible to measure the quite low dose radiation with stability and high sensitivity. Actually, the electrode was suspended by the teflon thread fixed on the steel cup levitated magnetically in the ionization chamber of which wall was covered by Al and equipped with an electrostatic charger for the electrode by noncontact. After measurement, the electrode was moved in the Faraday cage placed under the ...
1999-09-01
Energy Technology Data Exchange (ETDEWEB)
An alternative utilization is presented for the gaseous ionization chamber in the detection of energetic heavy ions, which is called Bragg Curve Spectroscopy (BCS). Conceptually, BCS involves using the maximum data available from the Bragg curve of the stopping heavy ion (HI) for purposes of identifying the particle and measuring its energy. A detector has been designed that measures the Bragg curve with high precision. From the Bragg curve the range from the length of the track, the total energy from the integral of the specific ionization over the track, the dE/dx from the specific ionization at the beginning of the track, and the Bragg peak from the maximum of the specific ionization of the HI are determined. This last signal measures the atomic number, Z, of the HI unambiguously.
1981-05-01
Position sensitive and Bragg curve spectroscopy detector system for heavy ion reaction studies
International Nuclear Information System (INIS)
A complete heavy ion identification system in heavy ion reaction studies consists, in general, of: 1) a position sensitive avalanche counter, and 2) ionization chamber to obtain total energy as well as a heavy ion identifier signal (such as the E#DELTA#E signal from a E-#DELTA#E type detector or the height of the Bragg peak that scales as Z of the heavy ion in a Bragg curve ionization chamber). In addition, a time-of-flight information may be needed to resolve the masses of the ions. With this motivation in mind, a composite detector system consisting of a Bragg curve spectroscopy ionization chamber (BCS-IC) and a one dimensional position sensitive parallel grid avalanche counter (XPS-PGAC) has been developed and used successfully at the BARC-TIFR pelletron accelerator facility. The design and performance of this gas detector system are reported. (author). 4 ...
Energy Technology Data Exchange (ETDEWEB)
The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration certificate and data sheets are presented. (author)
1999-07-01
The mass dependence of the signal peak height of a Bragg-curve ionization chamber
International Nuclear Information System (INIS)
The Bragg-curve detector of the parallel plate ionization chamber type generates a signal that is a distorted replica of the original Bragg-curve. In result of this distortion, the signal peak height is not only a function of the atomic number of the heavy ion, as it is often stated, but also of the particle mass. This mass effect was studied with the aid of computer simulation, and it was found to be dependent on the Frisch grid to anode gap width and on the detector gas. The charge resolution of the detector is affected very significantly by this mass dependence of the signal peak height. Therefore, a careful selection of the detector gas and the grid to anode gap width is necessary, if good charge resolution over a wide range of heavy ions is required. (orig.).
Mass dependence of the signal peak height of a Bragg-curve ionization chamber
Energy Technology Data Exchange (ETDEWEB)
The Bragg-curve detector of the parallel plate ionization chamber type generates a signal that is a distorted replica of the original Bragg-curve. In result of this distortion, the signal peak height is not only a function of the atomic number of the heavy ion, as it is often stated, but also of the particle mass. This mass effect was studied with the aid of computer simulation, and it was found to be dependent on the Frisch grid to anode gap width and on the detector gas. The charge resolution of the detector is affected very significantly by this mass dependence of the signal peak height. Therefore, a careful selection of the detector gas and the grid to anode gap width is necessary, if good charge resolution over a wide range of heavy ions is required.
1985-01-01
New focal plane detector system for the broad range spectrometer
Energy Technology Data Exchange (ETDEWEB)
A focal plane detector system consisting of a vertical drift chamber, parallel plate avalanche counters, and an ionization chamber with segmented anodes has been installed in the Broad Range Spectrometer at the Holifield Facility at Oak Ridge. The system, which has been designed for use with light-heavy ions with energies ranging from 10 to 25 MeV/amu, has a position resolution of approx. 0.1 mm, a scattering angle resolution of approx. 3 mrad, and a mass resolution of approx. 1/60.
1984-01-01
Secondary electron yield measurements from thin surface coatings for NLC electron cloud reduction
In the beam pipe of the positron damping ring of the Next Linear Collider, electrons will be created by beam interaction with the surrounding vacuum chamber wall and give rise to an electron cloud. Several solutions are possible for avoiding the electron cloud, without changing the bunch structure or the diameter of the vacuum chamber. Some of the currently available solutions for preventing this spurious electron load include reducing residual gas ionization by the beam, minimizing beam photon-induced electron production, and lowering the secondary electron yield (SEY) of the chamber wall. We will report on recent SEY measurements performed at SLAC on TiN coatings and TiZrV non-evaporable getter thin films.
2004-01-01
Particle identification through the measurement of the Bragg curve centroid
Energy Technology Data Exchange (ETDEWEB)
A new method of particle identification of heavy ions through the measurement of the Bragg curve centroid and particle energy has been developed using a gas ionization chamber with a resistive anode layer. Z-resolutions comparable to the conventional ..delta..E-E counter telescope could be rather easily attained.
1983-07-01
Particle identification through the measurement of the Bragg curve centroid
International Nuclear Information System (INIS)
A new method of particle identification of heavy ions through the measurement of the Bragg curve centroid and particle energy has been developed using a gas ionization chamber with a resistive anode layer. Z-resolutions comparable to the conventional #DELTA#E-E counter telescope could be rather easily attained. (orig.).
Particle identification by modified Bragg-curve centroid detection
Energy Technology Data Exchange (ETDEWEB)
A new article identification method based on the measurement of Bragg-curve centroids using a gas-filled ionization chamber has been improved for detection of low-energy particles around 1 MeV per nucleon by introducing a nonuniform distribution of resistance on the anode electrode. Almost the same quality of Z-resolutions as in the conventional ..delta..E-E method could be obtained up to Z=19.
1987-03-01
Nitrogen isotope identification by Bragg-curve spectroscopy
Energy Technology Data Exchange (ETDEWEB)
Projectilelike fragments following the 80 MeV /sup 16/O+/sup 27/Al reaction have been detected using a Bragg-curve spectroscopy ionization chamber (BCS-IC). The atomic number is deduced from the Bragg-peak amplitude. Nitrogen isotopes are clearly resolved using either range or energy loss data. This is the first application of the BCS method for complete ion identification in a heavy-ion-induced reaction.
1984-07-14
Nitrogen isotope identification by Bragg-curve spectroscopy
International Nuclear Information System (INIS)
Projectilelike fragments following the 80 MeV "1"6O+"2"7Al reaction have been detected using a Bragg-curve spectroscopy ionization chamber (BCS-IC). The atomic number is deduced from the Bragg-peak amplitude. Nitrogen isotopes are clearly resolved using either range or energy loss data. This is the first application of the BCS method for complete ion identification in a heavy-ion-induced reaction.
Bragg-curve spectroscopy at high rates
Energy Technology Data Exchange (ETDEWEB)
The performance of a Bragg ionization chamber has been investigated as a function of the counting rate with approx.= 5 MeV/amu /sup 32/S beams: up to approx.= 20 kHz the energy resolution is below 0.9% and the Z resolving power is more than 50. (orig.).
1986-03-01
Analyses of superficial and depth doses in intraoral radiology
Energy Technology Data Exchange (ETDEWEB)
In this work dosimetric analysis using thermoluminescence technique to study the beams characteristics of x-rays employed in dental radiology has been carried out. The obtained results with CaSO{sub 4}:Dy thermoluminescent dosimeters (TLD) were compared to the doses obtained with parallel-plates ionization chamber. Dosimetric evaluations were also done using radiographic films of large dimensions. The x-rays equipments analyzed were installed in the radiological services of Odontology Department of Sergipe Federal University (U.F.S.). Depending on the anatomical region to be examined the proper exposure time was select, for a fix voltage of 70 kV. The results with TLD and ionization chamber have been determined to female and male individuals. The intraoral regions analysed were the peri apical of the incisors, molar and pre-molar teeth and the occlusive region. These regions were simulated using acrylic ...
2006-07-01
Absolute fission rates in the FFTF
Energy Technology Data Exchange (ETDEWEB)
The part of the FFTF Reactor Characterization Program reported in this paper is a measurement of absolute fission rates of eight major fuel isotopes at two different positions within the reactor. The instruments employed in these tests were fission ionization chambers for which the absolute efficiency and fissionable deposit mass assay have been rigorously established.
1981-06-01
Clinical application of dosimetry in electron beam therapy
International Nuclear Information System (INIS)
In everyday radiotherapy we must carry out the determination of absorbed dose measurement according to JARP's protocol. We explained an outline of JARP's 1974 and 1986 protocol in electron beam therapy, and mentioned it about the matter that should examined. To use it easily in clinic, a simplified procedure based on precisely to JARP's 1986 protocol is practical, the character of this procedure settles briefly the determination of mean incident energy of electron beams and get ready to table of ionization to absorbed dose conversion factor for various ionization chamber. Also, this procedure almost not influence on the accuracy of determination. We described systematically practical procedure for requisite absorbed dose calculation in a patient in electron beam therapy. (author).
Position sensitive and Bragg curve spectroscopy detector system
Energy Technology Data Exchange (ETDEWEB)
A heavy ion gas detector system consisting of a Bragg-curve spectroscopy ionization chamber for particle identification and a multiwire proportional chamber as position sensitive fast trigger device is described. The Bragg IC has been tested with several beams up to Z=36 to investigate some aspects of the BCS method. Results are reported on energy resolution and linearity, Z resolving power and mass sensitivity. The energy resolution is well below 1%. The Bragg-peak amplitude is fairly independent of the energy in a wide energy range and single elements are identified up to Z=38 with a resolving power Z/..delta..Zproportional50-80. Isotope identification by range measurement is limited by the straggling in the ionization process and the mass resolving power is M/..delta..Mproportional20-26 for S and Si isotopes. The MWPC allows subnanosecond time resolution and position identification along the in-plane ...
1984-08-01
Position sensitive and Bragg curve spectroscopy detector system
International Nuclear Information System (INIS)
A heavy ion gas detector system consisting of a Bragg-curve spectroscopy ionization chamber for particle identification and a multiwire proportional chamber as position sensitive fast trigger device is described. The Bragg IC has been tested with several beams up to Z=36 to investigate some aspects of the BCS method. Results are reported on energy resolution and linearity, Z resolving power and mass sensitivity. The energy resolution is well below 1%. The Bragg-peak amplitude is fairly independent of the energy in a wide energy range and single elements are identified up to Z=38 with a resolving power Z/#DELTA#Zproportional50-80. Isotope identification by range measurement is limited by the straggling in the ionization process and the mass resolving power is M/#DELTA#Mproportional20-26 for S and Si isotopes. The MWPC allows subnanosecond time resolution and position identification along the in-plane ...
Detection system characteristics using sup 252 Cf ionization chambers
Energy Technology Data Exchange (ETDEWEB)
Because the number of neutrons and gamma rays and the energy spectrum of particles from spontaneous fission are well characterized for {sup 252}Cf, it can be used as a timed source of fission neutrons and gamma rays. The first such usage incorporated a {sup 252}Cf source into gas scintillators. This paper describes a timed source of neutrons and gamma rays made by depositing {sup 252}Cf on one electrode of a parallel plate ionization chamber that can then be used for determining detection-system characteristics. The emission time of neutrons from spontaneous fission has also been determined by recording the emission time of prompt gamma rays from a {sup 252}Cf source (not incorporated into a detector) adjacent to the surface of a solid or liquid scintillator. This well characterized source of neutrons can thus be used as a randomly pulsed source for a variety of applications. This paper illustrates the use of this type of source to determine ...
1990-01-01
Energy Technology Data Exchange (ETDEWEB)
This digest paper presents the theoretical project of a fission engine for space ship as imagined by Y. Ronen from the Ben-Gourion Univ. (Israel). In this engine, the combustion chamber is covered with metastable {sup 242}Am thin sheets. The fission reaction is triggered with a bombardment of neutrons and the fission fragments ionize a gas (hydrogen, for instance) which is overheated and ejected through the engine nozzle. (J.S.)
2002-01-01
Application of the digital waveform analysis to Bragg curve spectrometer
International Nuclear Information System (INIS)
Energy and angular double-differential cross-section (DDX) data of fragment production reactions by neutrons or protons are very scarce due to experimental difficulties of fragment detection. We adopted a Bragg curve spectrometer (BCS), which is a gridded-ionization chamber that can identify fragments on the basis of the Bragg peak value. We have been developing the BCS for neutron and proton-induced reactions applying the digital waveform analysis technique to obtain better ability of particle discrimination than the analog electronic circuit. (T. Tanaka)
2004-11-01
A multiple sampling proportional counter for particle identification of relativistic heavy ions
Energy Technology Data Exchange (ETDEWEB)
A multiple sampling dE/dx counter using a multiwire proportional chamber equipped with catbode pads was constructed for the multiple detection of dE/dx values along a particle trajectory. For low-energy particles this counter was proved to be useful as a Bragg-curve detector. At relativistic energies around E=14.6 GeV/nucleon good particle identification was obtained by cathode pad signals as well as anode signals for the range of projectile fragments from Z=1 (minimum ionization) up to a beam charge of Z=14. (orig.).
1990-11-15
A new method, near-infrared laser desorption/ionization aerosol mass spectrometry (NIR-LDI-AMS), is described for the real time analysis of organic aerosols at atmospherically relevant mass loadings. Use of a single NIR laser pulse to vaporize and ionize particle components deposited on an aluminum probe results in minimal fragmentation to produce exclusively intact pseudomolecular anions at [M-H](-). Limits of detection (total particulate mass sampled) for oxidized compounds of relevance to atmospheric primary and secondary organic aerosol range from 89 fg for pinic acid to 8.8 pg for cholesterol. NIR-LDI-AMS was used in conjunction with the University of Vermont Environmental Chamber to study secondary organic aerosol (SOA) formation from ozonolysis of limonene at total aerosol mass loadings ranging from 3.2 to 25.0 ?g m(-3) and with a time resolution of several minutes. NIR-LDI-AMS permitted direct delineation between ...
2010-10-01
Energy Technology Data Exchange (ETDEWEB)
Energy and angular double differential cross-section data of fragments by tens of MeV neutron or proton are important to evaluate dosimetry and radiation effect in devices or instruments, since fragments cause a large local ionization. Up to now, experimental data of the fragment production are very scarce due to experimental difficulties of fragment detection. A bragg curve spectrometer (BCS) for fragment measurement is a gridded-ionization chamber that identify fragments on the basis of the difference of Bragg peak value. The BCS was fabricated to adopt for fragment measurement in neutron-induced reactions and tested with a charged-particle beam and then applied to a neutron field successfully. The structure of BCS is a cylindrical gridded ionization chamber, and filled with a Ar + 10% CH{sub 4} gas at a pressure of 2.7 x 10{sup 4} Pa. To confirm the performance of BCS, the ...
2002-09-01
Measurement of the /SUP 242m/ Am neutron fission cross section
Energy Technology Data Exchange (ETDEWEB)
The fission cross section of /SUP 242m/ Am has been measured from 0.005 eV to 20 MeV using time-of-flight techniques at the Oak Ridge Electron Linear Accelerator. A hemispherical plate fission ionization chamber with five pairs of plates contained three deposits totaling 507 ..mu..g of /SUP 242m/ Am, one deposit of 168 ..mu..g /sup 235/U, and a ''weightless'' deposit of /sup 252/Cf, which served as a monitor of chamber performance. The fission of /sup 235/U, served as the cross-section standard for energies above 101 keV while /sup 6/Li(n,..cap alpha..), normalized to /sup 235/U fission in the 7.8- to 11.0-eV interval, served as a shape standard below 101 keV. Approximately 360 h of data were obtained at a flight path distance of 9.1 m, primarily with 40-ns bursts. Particular attention was paid to correction of backgrounds, especially inscattered-neutron-induced events. The fission ...
1983-05-01
Measurement of the /SUP 242m/ Am neutron fission cross section
International Nuclear Information System (INIS)
The fission cross section of /SUP 242m/ Am has been measured from 0.005 eV to 20 MeV using time-of-flight techniques at the Oak Ridge Electron Linear Accelerator. A hemispherical plate fission ionization chamber with five pairs of plates contained three deposits totaling 507 #mu#g of /SUP 242m/ Am, one deposit of 168 #mu#g "2"3"5U, and a ''weightless'' deposit of "2"5"2Cf, which served as a monitor of chamber performance. The fission of "2"3"5U, served as the cross-section standard for energies above 101 keV while "6Li(n,#alpha#), normalized to "2"3"5U fission in the 7.8- to 11.0-eV interval, served as a shape standard below 101 keV. Approximately 360 h of data were obtained at a flight path distance of 9.1 m, primarily with 40-ns bursts. Particular attention was paid to correction of backgrounds, especially inscattered-neutron-induced events. The fission resonance integral was found to be 1800 + or - 65 b.
X-ray exposure in the teaching of science at junior and senior high schools
Energy Technology Data Exchange (ETDEWEB)
A significant amount of X-rays were detected as a leakage from some of the Crooke`s tubes which were used in the teaching of science at junior and senior high schools in Japan. We measured the leaked dose of X-rays from the Crooke`s tubes with ionizing chambers, film badges and TLDs. The maximum leaked dose at 5cm distance from those tubes was estimated 143mSv/h. The effective energy of leaked X-rays was 19.3keV. The maximum dose of students exposed during the teaching of science were estimated 0.15mSv per experiment, which exceeded the value recommended in the ICRP publication 36. (author)
1995-10-01
The propagation of relativistic heavy ions in multielement beam lines.
We describe calculations of the energy loss, range, stopping power, multiple scattering, and other related properties of a high-energy heavy-ion beam at any one of a set of beam line elements. A beam line element (e.g., any beam modification, detection, or control device) is characterized by its thickness, areal density, aperture, and function. The loss of multiply scattered particles to any finite-aperture detector is calculated in the small-angle approximation, and the position of the Bragg peak, as given by particles stopping in the second of two ionization chambers used for Bragg curve measurements, is estimated. A general purpose computer program, PROPAGATE, has been written to allow addition, deletion, and modification of the beam line elements used in the calculation and to provide a convenient means of repeating such calculations for arbitrary beam lines. Calculations and experimental measurements are compared and found to be in ...
Physical and mathematical description of Nuclear Weapons Identification System (NWIS) signatures
Energy Technology Data Exchange (ETDEWEB)
This report describes all time and frequency analysis parameters measured with the new Nuclear Weapons Identification System (NWIS) processor with three input channels: (1) the {sup 252}Cf source ionization chamber; (2) a detection channel; and (3) a second detection channel for active measurements. An intuitive and physical description of the various functions is given as well as a brief mathematical description and a brief description of how the data are acquired. If the full five channel capability is used, the number of functions increases in number but not in type. The parameters provided by this new NWIS processor can be divided into two general classes: time analysis signatures including multiplicities and frequency analysis signatures. Data from measurements with an 18.75 kg highly enriched uranium (93.2 wt%, {sup 235}U) metal casting for storage are presented to illustrate the various time and frequency analysis parameters.
1997-09-26
Physical and Mathematical Description of Nuclear Weapons Identification System (NWIS) Signatures
Energy Technology Data Exchange (ETDEWEB)
This report describes all time and frequency analysis parameters measured with the new Nuclear Weapons Identification System (NWIS) processor with three input channels: (1) the 252Cf source ionization chamber (2) a detection channel; and (3) a second detection channel for active measurements. An intuitive and physical description of the various functions is given as well as a brief mathematical description and a brief description of how the data are acquired. If the fill five channel capability is used, the number of functions increases in number but not in type. The parameters provided by this new NWIS processor can be divided into two general classes: time analysis signatures including multiplicities and frequency analysis signatures. Data from measurements with an 18.75 kg highly enriched uranium (93.2 wt 0/0, 235U) metai casting for storage are presented to illustrate the various time and frequency analysis parameters.
1997-09-26
Performance of a Bragg curve detector for heavy ion identification
Energy Technology Data Exchange (ETDEWEB)
By using Bragg curve spectroscopy, one can measure atomic number and energy of high energy heavy ions stopping in a gas-filled ionization chamber with longitudinal electric field. In this paper, we report on the results obtained with an isobutane filled detector. An energy resolution of 0.8% fwhm and a Z resolution of 2.7% fwhm were achieved for elastically scattered 300 MeV /sup 40/Ar ions. We study the Bragg peak amplitude dependence on the energy of the incoming ions, a dependence presumably due to the Frisch grid screening inefficiency. The corrected Bragg peak spectrum of inelastically scattered 300 MeV /sup 40/Ar ions exhibits a satisfactory Z separation around Z = 18.
1982-12-15
Performance of a Bragg curve detector for heavy ion identification
International Nuclear Information System (INIS)
By using Bragg curve spectroscopy, one can measure atomic number and energy of high energy heavy ions stopping in a gas-filled ionization chamber with longitudinal electric field. In this paper, we report on the results obtained with an isobutane filled detector. An energy resolution of 0.8% fwhm and a Z resolution of 2.7% fwhm were achieved for elastically scattered 300 MeV "4"0Ar ions. We study the Bragg peak amplitude dependence on the energy of the incoming ions, a dependence presumably due to the Frisch grid screening inefficiency. The corrected Bragg peak spectrum of inelastically scattered 300 MeV "4"0Ar ions exhibits a satisfactory Z separation around Z = 18. (orig.).
Particle identification for heavy ions in a time-of-flight spectrometer
Energy Technology Data Exchange (ETDEWEB)
A time-of-flight (TOF) spectrometer has been constructed at the JAERI 20 MV tandem accelerator facility. A position-sensitive start detector, which consists of a thin carbon foil, microchannel plates and a resistive plate, was developed for the TOF measurements through the spectrometer. The time and position resolutions obtained were 120 ps and 0.3 mm for ..cap alpha.. particles from /sup 241/Am, respectively. A two-dimensional position-sensitive detector was also developed to measure the solid angle of the spectrometer and the maximum solid angle obtained was 9.5 msr. As a particle detector a Bragg curve ionization chamber was developed. From the Bragg curves of heavy ions in the detector, energies, ranges and Bragg curve peaks were measured and used for particle identification. The resolving power Z/..delta..Z of the atomic number was about 50.
1982-05-01
Neutron-induced fission cross-section of {sup 233}U in the energy range 0.5<E{sub n}< 20 MeV
Energy Technology Data Exchange (ETDEWEB)
The neutron-induced fission cross-section of {sup 233}U has been measured at the CERN n-TOF facility relative to the standard fission cross-section of {sup 235}U between 0.5 and 20MeV. The experiment was performed with a fast ionization chamber for the detection of the fission fragments and to discriminate against {alpha} -particles from the natural radioactivity of the samples. The high instantaneous flux and the low background of the n-TOF facility result in data with uncertainties of {approx} 3%, which were found in good agreement with previous experiments. The high quality of the present results allows to improve the evaluation of the {sup 233}U (n,f) cross-section and, consequently, the design of energy systems based on the Th/U cycle. (orig.)
2011-01-15
International Nuclear Information System (INIS)
Relative doses of 75 MeV/u "1"2C ion beam after passing through different thickness of degraders were measured with the double ionization chamber method. The degrader's thickness equalized to penetration depth of the beam in water and its Bragg curve were obtained. The measured Bragg curve is compared with that calculated based on a model set up by the authors. Meanwhile, the inactivation effect of the ion beam passing through different thickness of degraders on melanoma (B_1_6) cells was measured, and the corresponding survival fraction data for B_1_6 cells were acquired
1998-08-01
IAEA RESEARCH CONTRACTS FIRST ANNUAL REPORT. Technical reports Series No. 4
Summaries are included of research contracts which expired prior to Dec. 31, 1960. The contracts were concerned with investigations of: electrophysiological responses of biological systems in nerve cells to irradiation with small doses of ionizing radiations; the mode of the protective action of certain sulfhydryl compounds against radiation effects on the synthesis of deoxyribonucleic acid, using tritium-labeled thymidine; development of a bubble chamber method of monitoring and dosimetry for Low fast neutron fluxes; effects of incorporated radioisotopes on the stability of genetic materials; interrelation of root and leaf absorption of radioisotopes in herbaceous plants; uptake of radioactive wastes by lowland rice from soils contaminated by irrigation water, and decontamination of the rice; and comparison between mutation rates induced by acute and chronic gamma irradiations. (B.O.G.)
1961-01-01
Estimated fetal radiation dose from multislice CT studies
International Nuclear Information System (INIS)
It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.
British Library Electronic Table of Contents (United Kingdom)
Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle3 treatment planning system, and the dose was calculated in a water phantom. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as w...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
The /sup 252/Cf-source-driven noise analysis method determines the subcriticality of a system containing fissionable material from the ratio of cross power spectral densities between the detectors that detect particles from the fission process and between these detectors and an ionization chamber containing a spontaneously fissioning neutron source which provides neutrons to induce fission in the system. This method has two advantages: (1) a calibration is not required and thus subcriticality can be determined from measurements only on the subcritical system of interest, and (2) the subcriticality is independent of the type of detector or its efficiency. These properties of this technique are illustrated by measurements.
1984-01-01
International Nuclear Information System (INIS)
The widespread use of building materials with relatively high radium concentrations may increase population exposure. A method is presented for measuring effective diffusion coefficients and exhalation rates of radon from such materials. Equations for use in the experimental determination of these values are obtained theoretically. The experimental set-up consists of a container which is hermetically sealed to a slab of the building material. Nitrogen is blown through the container and then through an ionization chamber which is connected to an electrometer and X-Y plotter, and the radon concentration is measured continuously. Exhalation rates of radon from some major building materials measured by this method will be used as reference levels. The method can also be used to determine other properties such as porosity. (author).
Tritium release from lithium orthosilicate pebbles deposited with palladium
International Nuclear Information System (INIS)
Full text of publication follows: Slightly over-stoichiometric lithium orthosilicate pebbles have been selected as one optional breeder material for the European Helium Cooled Pebble Bed (HCPB) blanket. This material has been developed in collaboration of Research Center Karlsruhe and the Schott Glass, Mainz. The lithium orthosilicate pebbles are fabricated from lithium hydroxide and silica by a melting and spraying method in a semi-industrial scale facility. Lithium hydroxide was selected as the precursor since enriched lithium hydroxide is commercially available. The lithium orthosilicate pebbles produced by the process contains oxide phases besides orthosilicate, but it was also found that the oxide phases can be decomposed by annealing at high temperatures. The lithium orthosilicate pebbles produced in this way possesses satisfactory pebble characteristics. Therefore, the authors performed out-of-pile annealing tests using the lithium orthosilicate pebbles irradiated in a research ...
2007-12-10
International Nuclear Information System (INIS)
The purpose of this study is to evaluate the accuracy of dose calculations by three algorithms. Depth dose, OPF (Output Factor) and dose profiles were measured in a heterogeneous phantom. These values were also calculated by three algorithms of the Batho power law (BPL), Equivalent-Tissue Air Ratio (ETAR) and Convolution superposition (CS). The data were obtained for 4, 6 and 10 MV photon beams with a linear accelerator (Varian 21EX). Field size ranged from 3 x 3 cm"2 to 10 x 10 cm"2. Dose profiles of beam penumbra were also measured by a 0.125 ml ionization chamber at the point of 8, 13 and 18 cm from the surface of the phantom at intervals of 1 mm. Differences between measured and calculated depth doses were within 2% in BPL and CS, but depth doses were overestimated in ETAR. OPFs were also overestimated with the error of more than 4% in ETAR. Absorbed dose calculated by CS were in agreement with the values measured by the ...
2004-12-01
Study on dose distribution of therapeutic proton beams with prompt gamma measurement
Energy Technology Data Exchange (ETDEWEB)
The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma distribution was compared to the dose distribution measured by an ionization chamber at three different ...
2007-03-15
Wire chamber degradation at the Argonne ZGS
International Nuclear Information System (INIS)
Experience with multiwire proportional chambers at high rates at the Argonne Zero Gradient Synchrotron is described. A buildup of silicon on the sense wires was observed where the beam passed through the chamber. Analysis of the chamber gas indicated that the density of silicon was probably less than 10 ppM.
1986-01-16
Wire chamber degradation at the Argonne ZGS
Energy Technology Data Exchange (ETDEWEB)
Experience with multiwire proportional chambers at high rates at the Argonne Zero Gradient Synchrotron is described. A buildup of silicon on the sense wires was observed where the beam passed through the chamber. Analysis of the chamber gas indicated that the density of silicon was probably less than 10 ppM.
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
As part of a U.S. multi-regional pilot study conducted by the six Centers for Radiological Physics, 12-mm-diameter by 0.4-mm-thick CaSO/sub 4/:Dy Teflon-embedded discs were evaluated and used to measure patient entrance exposure on 60 average patients at 12 clinical centers. The discs were found to have adequate sensitivity, reproducibility and linearity up to 69.7 microC kg-1 (270 mR). The minimum measurable exposure was estimated as 0.4 microC kg-1 (1.5 mR). All responses were corrected for energy dependence, which varied +/- 20% from 1.7 to 6.5 mm Al half-value layer. Patient entrance exposure values ranged from 1.3 to 28 microC kg-1 (5 to 110 mR), with a median value of 5.2 microC kg-1 (20 mR). This value agreed with exposure measurements made on the chest radiography equipment using an ionization chamber and a phantom which simulated an average patient, and with published Nationwide Evaluation of X-Ray Trends (NEXT) data for the same ...
1987-12-01
The DITE (Divertor Injection Tokamak Experiment) program has been undertaken to demonstrate the feasibility of impurity control by the use of a diverter in an injection-heated toroidal plasma configuration. Rather than behaving in accordance with neoclassical toroidal containment theory, the plasma is subject to various instabilities, particularly the resistive fluid MHD types, follows the empirical scaling of energy confinement time with plasma parameters observed in other plasma devices. DITE experiments have, however, extended the range of current and density. Impurities arising from plasma interactions with the vacuum vessel surface are controlled by the bundle divertor, which diverts a portion of plasma and power in the plasma scrape-off layer into a separate target chamber where impurities can be removed. Auxiliary plasma heating is provided by the injection of powerful beams of neutral hydrogen atoms produced by multi-aperture ion sources and hydrogen gas ...
1981-04-01
Subcritical measurements using the /sup 252/Cf source-driven neutron noise analysis method
Energy Technology Data Exchange (ETDEWEB)
This paper describes recent measurements of the subcritical neutron multiplication factor using the /sup 252/Cf source-driven neutron noise analysis method. This work was supported by a program of collaboration between the United States Department of Energy and the Power Reactor and Nuclear Fuel Development Corporation of Japan related to the development of fast breeder technology. The experiment reported consists of a configuration of two interacting tanks of uranyl nitrate aqueous solution with different uranium concentrations in each tank. The /sup 252/Cf-source-driven neutron noise analysis method obtains the subcriticality from the signals of three detectors: the first, a parallel plate ionization chamber with /sup 252/Cf electroplated on one of its plates that is located in or near the system containing the fissile material, and produces an electrical pulse for every spontaneous fission that occurs and thereby serves as a timed source of ...
1985-01-01
High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics was used to characterize the pulse rise time of deposited gamma ...
2000-01-01
Energy Technology Data Exchange (ETDEWEB)
A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL sheet was suggested to provide a convenient means of measuring the dose distribution around {sup 60}Co ...
1991-06-01
Measurement of "2"3"3U(n,f) cross-section at n_TOF facility. Statistical analysis
International Nuclear Information System (INIS)
The "2"3"3U(n, f) cross-section has been measured at n_TOF in a wide energy range with a dedicated fission ionization chamber. We report here the results from 0.30 meV to 1 MeV neutron energy. The "2"3"3U(n, f) cross-section has been determined relative to a reference sample of "2"3"5U(n, f) measured simultaneously with the same detector. The very high instantaneous neutron flux and the intrinsically low background of the n TOF installation result in an accuracy around 3% in the whole energy range, while the energy resolution of the neutron beam allows for an accurate description of the fission cross-section by means of R-matrix analysis over a wide energy range. The present data provide the basis for a more precise evaluation of the "2"3"3U fission cross-section, and for improving the reliability of databases needed for the design of new energy systems based on the Th/U cycle. (Author)
2009-02-01
BEATRIX-II: In situ tritium test
Energy Technology Data Exchange (ETDEWEB)
The BEATRIX-II irradiation experiment is an in-situ tritium release experiment being carried out in the Fast Flux Test Facility (FFTF) reactor to evaluate the tritium release characteristics of fusion solid breeder materials. A sophisticated tritium gas handling system has been developed to continuously monitor the tritium recovery from the specimens and facilitate tritium removal from the experiment's sweep gas flow stream. The in-situ recovery experiment accommodates two different in-reactor specimen canisters with individual gas streams and temperature monitoring/control. Ionization chambers have been specifically designed to respond to the rapid changes in the tritium release rate at the anticipated tritium concentrations. Two ceramic electrolysis cells have proved effective in reducing the moisture in the gas streams to hydrogen/tritium. A tritium getter system, capable of reducing the tritium level by a factor greater than 4000, ...
1990-01-01
Automatic system for measuring dose-area product (DAP) in ROI fluoroscopy
Energy Technology Data Exchange (ETDEWEB)
A computerized system for monitoring dose-area product (DAP) has been developed for region of interest (ROI) fluoroscopy in which patient exposure is reduced using an x-ray attenuating filter with an aperture. The system includes an IBM compatible computer which is connected through an IEEE-488 interface to an electrometer which measures the charge from a DAP ionization chamber. A digital input/output board connects the computer to the filter placement device to determine whether the filter is in or out of the beam, and to the x-ray generator to determine when the exposure is due to spot filming. The computer logs the DAP from conventional fluoroscopy, ROI fluoroscopy and spot filming separately, applying the appropriate calibration factor for each. Measured DAPs, fluoroscopic DAP rates and exposure times are displayed in real-time. The system has been installed in a GI fluoroscopic room so that the dose-reduction potential of ROI imaging can ...
1997-04-01
Energy Technology Data Exchange (ETDEWEB)
The aim of this work was to study acute alterations of the enterohepatic recirculation (EHR) of bile acids 3 days after an 8-Gy radiation exposure in vivo in the rat by a washout technique. Using this technique in association with HPLC analysis, the EHR of the major individual bile acids was determined in control and irradiated animals. Ex vivo ileal taurocholate absorption was also studied in Ussing chambers. Major hepatic enzyme activities involved in bile acid synthesis were also measured. Measurements of bile acid intestinal content and intestinal absorption efficiency calculation from washout showed reduced intestinal absorption with significant differences from one bile acid to another: absorption of taurocholate and tauromuricholate was decreased, whereas absorption of the more hydrophobic taurochenodeoxycholate was increased, suggesting that intestinal passive diffusion was enhanced, whereas ileal active transport might be reduced. Basal hepatic secretion ...
2004-02-01
International Nuclear Information System (INIS)
An aerial radiological survey was performed from 11 to 20 March 1982 over a 260-square-kilometer area centered on the Grand Gulf Nuclear Station at Port Gibson, Mississippi (the station was not yet in operation at the time of the survey). All gamma ray data were collected by flying east-west lines spaced 152 meters apart at an altitude 91 meters above ground level. Processed data showed that all gamma rays detected within the survey area were those expected from naturally occurring terrestrial background emitters. Count rates obtained from the aerial platform were converted to exposure rates at 1 meter above the ground and are presented in the form of an isoradiation contour map. The observed exposure rates were between 5 and 13 microroentgens per hour (#mu#R/h), with most of the area ranging from 9 to 10 #mu#R/h. These values include an estimated cosmic ray contribution of 3.6 #mu#R/h. The exposure rate obtained from soil samples and ionization ...
APMP/TCRI key comparison report of measurement of air kerma for medium-energy x-rays (APMP.RI(I)-K3)
Energy Technology Data Exchange (ETDEWEB)
The APMP/TCRI Dosimetry Working Group performed the APMP.RI(I)-K3 key comparison of measurement of air kerma for medium-energy x-rays (100 kV to 250 kV) between 2000 and 2003. In total, 11 institutes took part in the comparison, among which 8 were APMP member laboratories. Two commercial cavity ionization chambers were used as transfer instruments and circulated among the participants. All the participants established the 100 kV, 135 kV, 180 kV and 250 kV x-ray beam qualities equivalent to those of the BIPM. The results showed that the maximum difference between the participants and the BIPM in the medium-energy x-ray range, evaluated using the comparison data of the linking laboratories ARPANSA and PTB, is less than 1.4%. The degrees of equivalence between the participants are presented and this comparison confirms the calibration capabilities of the participating laboratories. (authors)
2008-10-15
/sup 252/Cf-source-driven neutron noise analysis measurements for coupled uranium metal cylinders
Energy Technology Data Exchange (ETDEWEB)
The /sup 252/Cf-source-driven neutron noise analysis method for obtaining the subcriticality of an assembly of fissile material from cross-power spectral densities (CPSDs) was developed to avoid some difficulties inherent in other measurement methods. This method requires measurement of frequency-dependent CPSD between a pair of detectors in or near the fissile assembly and CPSDs between these detectors and a source of correlated neutron noise from an ionization chamber containing /sup 252/Cf, also in or near the fissile assembly. Also, the auto-power spectral density of the source is required. The ratio of spectral densities is then formed and is related to the subcriticality. To date various measurements have been performed which demonstrate the usefulness of the method including measurements with single uranium metal cylinders. The experiments described here, which used coupled uranium (93.15 wt % /sup 235/U) metal cylinders separated by ...
1985-01-01
International Nuclear Information System (INIS)
An extensive set of benchmark measurement of PDDs and beam profiles was performed in a heterogeneous layer phantom, including a lung equivalent heterogeneity, by means of several detectors and compared against the predicted dose values by different calculation algorithms in two treatment planning systems. PDDs were measured with TLDs, plane parallel and cylindrical ionization chambers and beam profiles with films. Additionally, Monte Carlo simulations by meansof the PENELOPE code were performed. Four different field sizes (10x10, 5x5, 2x2, and1x1 cm"2) and two lung equivalent materials (CIRS, #rho#_e"w=0.195 and St. Bartholomew Hospital, London, #rho#_e"w=0.244-0.322) were studied. The performance of four correction-based algorithms and one based on convolution-superposition was analyzed. The correction-based algorithms were the Batho, the Modified Batho, and the Equivalent TAR implemented in the Cadplan (Varian) treatment planning system and ...
2004-10-01
International Nuclear Information System (INIS)
Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle"3 treatment planning system, and the dose was calculated in a water phantom. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as well as its spatial dosimetric characteristics. Results: Agreement within 5.0% was observed between the Pinnacle"3 predicted dose distributions and the ...
2009-10-01
Electron-beam-plasma ion source as source of negative fluorine
Energy Technology Data Exchange (ETDEWEB)
Radioactive ion beams (RIBs) of short-lived isotopes of fluorine are in demand for investigating astrophysical phenomena related to the hot CNO cycle and rp processes responsible for stellar nucleosynthesis. Since negative ion beams are required for injection into tandem electrostatic accelerators, such as the 25 MV tandem accelerator used for post acceleration of RIBs for the Holifield Radioactive Ion Beam Facility (HRIBF) research program at the Oak Ridge National Laboratory (ORNL), efficient, direct-formation F{sup -} ion sources are highly desirable for RIB applications involving this type of post-accelerator. We have conceived and evaluated a direct extraction F{sup -} source for potential RIB applications which is predicated on the reverse polarity operation of a positive electron-beam-plasma target/ion source (EBPTIS) while simultaneously feeding fluorine rich compounds and Cs vapor into the source. The source is found to operate in two separately distinct temperature regimes ...
1997-11-01
Apparatus for measuring the decontamination factor of a multiple filter air-cleaning system
Energy Technology Data Exchange (ETDEWEB)
An apparatus is described for measuring the overall decontamination factor of first and second filters, the first and second filters being located in a plenum having an upstream chamber, an intermediate chamber, and a downstream chamber. The first filter is located between the upstream and intermediate chambers and the second filter is located between the intermediate and downstream chambers. The apparatus comprises a. an aerosol generator for producing a challenge aerosol composed of individual particles, the aerosol generator being in fluid communication with the upstream chamber; b. an upstream collector for collecting the challenge aerosol before the challenge aerosol enters the first filter, the upstream collector being disposed in the upstream chamber; c. an intermediate collector for collecting the challenge aerosol that passes ...
1986-10-28
Constraints on target chamber first wall and target designs that will enable NIF debris shields to survive
1999-01-01
The Ames infrared spectral database of isolated, neutral and ionized polycyclic aromatic
1999-01-01
Modified Helium microwave-induced plasma discharge chamber
International Nuclear Information System (INIS)
... Mohamed, MM Medical Research Institute (Egypt) Ghatass, ZF Institute of
1999-04-01
Ignition Phenomena in Developmental, Stick Propellant ...
... TEMPERATURE, PRESSURE MEASUREMENT, GUN CHAMBERS, COMPACTING, COMBUSTIBLE CARTRIDGE CASES, FLASH RADIOGRAPHY ...
1984-07-01
Energy Technology Data Exchange (ETDEWEB)
A fuel injector comprises first and second housing parts, the first housing part being located within a bore or recess formed in the second housing part, the housing parts defining therebetween an inlet chamber, a delivery chamber axially spaced from the inlet chamber, and a filtration flow path interconnecting the inlet and delivery chambers to remove particulate contaminants from the flow of fuel therebetween.
2001-02-27
Cylindrical drift chamber with three-dimensional data readout
International Nuclear Information System (INIS)
A multiwire cylindrical drift chamber is the main detector of the AMPIR 4#pi#-spectrometer for studying pion-nucleon reactions. The chamber has possibility to measure three coordinates by the electron drift time and by the charge division method. Chamber design and geometry, test bench, readout electronics and also results of calculations, simulation and tests are described.
Cylinder drift chamber with three-dimensional data output
A cylindrical multiwire drift chamber is the central detector of the AMPIR spectrometer. It has 4{pi} acceptance angle and was designed to study pion-nucleon reactions. The chamber can determine the three coordinates through the electron drift time and charge division ration. The paper describes the layout and design of the chamber, the test bench, the data output circuit, the design parameters, and the results of computer simulations and tests.
1995-03-01
Cylinder drift chamber with three-dimensional data output
International Nuclear Information System (INIS)
A cylindrical multiwire drift chamber is the central detector of the AMPIR spectrometer. It has 4#pi# acceptance angle and was designed to study pion-nucleon reactions. The chamber can determine the three coordinates through the electron drift time and charge division ration. The paper describes the layout and design of the chamber, the test bench, the data output circuit, the design parameters, and the results of computer simulations and tests.
Stochastic risk estimation from medical x-ray diagnostic examinations, 2
International Nuclear Information System (INIS)
The risks of genetic, leukemia and malignant diseases from medical X-ray diagnostic examinations were estimated using the frequency of radiographic and fluoroscopic exposures per diagnostic examination, child expectancy, leukemia and malignancy significant factors, and using a weighting factor determined on the basis of data concerning the cancer mortality among atomic bomb survivors in Nagasaki and of a recommendation of International Commission of Radiological Protection. The organ or tissue doses with respect to the stochastic risks were determined with ionization chambers and thermoluminescent dosimeters placed at the positions of the organs or tissues in a RANDO woman phantom which was exposed to diagnostic X-rays according to technical factors of typical radiographic and fluoroscopic examinations obtained from a nationwide survey. The resultant risks by age-group and type of radiographic and fluoroscopic examination are tabulated in terms ...
1981-01-01
Radon exhalation from and diffusion in concrete
International Nuclear Information System (INIS)
Cylindrical test pieces of concrete are used for measurements of "2"2"2Rn exhalation rates. Except one flat end surface of a test piece, other parts of its exteriority are covered with sealant. Radon atoms can escape only through its end surface from the interior into the outside air. This treatment makes the radon transport in the concrete one dimensional phenomena. The piece is put in an airtight container. Time variations of radon concentrations in the air of the container are measured with a plane multiwire-electrode ionization chamber. From this result, the radon areal exhalation rate is deduced for the piece. Exhalation rates are measured for four pieces with different length. Then, the diffusion coefficient is obtained for radon in the concrete as (5.0 #+-# 1.0) x 10"-"8m"2s"-"1 (a one-block method). A two-block method has been invented to obtain simultaneously values of three parameters: diffusion coefficient, porosity of concrete, and ...
1990-12-01
Quality control in medical radiology using T.L.D
Energy Technology Data Exchange (ETDEWEB)
In this work tests of quality control in beams of X rays have been carried out, at diagnostic level, of two radiological services equipments of Brazilian hospitals (Aracaju, SE). We obtained the air kerma and kerma rate values, the beams efficiency, the coherence between the luminous fields and the referring fields of irradiation and half-value layer to each equipment and set of parameters. The measures of direct form have been obtained using two ionization chambers, one cylindrical and another one with parallel plates. An optional method for accomplishment some of the tests were carried out with CaSO{sub 4}:Dy + Teflon thermoluminescent dosimeters. The values of air kerma were evaluated for three tube voltage, 40, 60 and 81 kV at 1.0 m from the focus of the equipments. For each one of the voltages three distinct current values were chosen besides a fixed value of exposition time. The results showed that the values of air kerma varied between ...
2006-07-01
Population doses from beam-therapy in Japan, 1978, 3
International Nuclear Information System (INIS)
As a series of estimations of population doses and of risk estimates from medical exposures in Japan, the malignancy significant dose (MSD) and the fatal malignant risk from beam therapy were estimated based on a nationwide survey of radiotherapeutic treatments, using a malignancy significant factor and a weighting factor determined from the data on the cancer mortality among the atomic bomb survivors in Nagasaki. The effective dose was defined as a sum of the product of the weighting factor and the organ or tissue doses with respect to the malignant diseases. The organ or tissue doses were determined with ionization chambers placed at the positions of their center in a MixDp-phantom simulated lung tissues by a block of cork, using a telecobalt unit, a conventional X-ray unit and a medical linear accelerator. The organ or tissue doses were categorized into three dose components; namely 1) dose from useful beams; 2) scattered radiation dose from ...
1981-01-01
Energy Technology Data Exchange (ETDEWEB)
'Improvement in understanding of the deposition of ambient dust particles on ECAM (Environmental Continuous Air Monitor) filters, reduction of the alpha-particle interference of radon progeny and other radioactive aerosols in different particle size ranges on filters, and development of ECAM''s with increased sensitivity under dusty outdoor conditions. As of May 1, 1998 (1/2 year into the project) the research-prototype 30-cm pulsed ionization chamber (PIC) is assembled and operational with an alpha particle energy resolution of better than 45 keV for 5-MeV alpha particles. Measurements of spectral resolution for alpha particles from radon decay products have been made as a function of filter type and dust loading conditions. So far, a study of ten filter types has found that the best combination of resolution and throughput is obtained with 3.0 \\265m Millipore fluoropore and 1.0 \\265m Corning FNMB filters. ...
1998-06-01
International Nuclear Information System (INIS)
The "2"3"3U(n,f) cross section has been measured at the white neutron source n_TOF in a wide energy range with a dedicated fission ionization chamber. We report here the results from #approx#30 meV to 1 MeV neutron energy. The "2"3"3U(n,f) cross section has been determined relative to a reference sample of "2"3"5U(n,f) measured simultaneously with the same detector. The very high instantaneous neutron flux and the intrinsically low background of the n_TOF installation result in an accuracy around 3% in the whole energy range, while the energy resolution of the neutron beam allows for an accurate description of the fission cross section by means of R-matrix analysis over a wide energy range. The results are, in general, in good agreement with the most recent high-accuracy measurement of this fission cross section, over the more limited range of the previous measurements, and indicated that even the latest evaluations underestimate the cross ...
2009-10-01
Low emissions compression ignited engine technology
Energy Technology Data Exchange (ETDEWEB)
A method and apparatus for operating a compression ignition engine having a cylinder wall, a piston, and a head defining a combustion chamber. The method and apparatus includes delivering fuel substantially uniformly into the combustion chamber, the fuel being dispersed throughout the combustion chamber and spaced from the cylinder wall, delivering an oxidant into the combustion chamber sufficient to support combustion at a first predetermined combustion duration, and delivering a diluent into the combustion chamber sufficient to change the first predetermined combustion duration to a second predetermined combustion duration different from the first predetermined combustion duration.
2007-04-03
Radiation chloration sulfochloration and sulfooxidation of organic compounds
International Nuclear Information System (INIS)
... halogenation ionizing radiations kinetics radiations reaction kinetics
Energy Technology Data Exchange (ETDEWEB)
Presently, most charge state distributions produced with highly charged ion sources are predicted with models that approximate the ionization process with the Lotz formula. The Lotz ionization cross sections decrease approximately geometrically with increasing charge state except for ions with very few vacancies, for ions with very few electrons, and for electron impact energies which barely exceed the ionization energy. The geometrical decrease causes these models to predict a maximum abundance for most of the charge states, which is only weakly dependent on the charge state. Experimental results, however, yield much higher abundances for ions with an empty M shell than ions with a partly filled M shell. This difference is explained with indirect ionization processes that are neglected by the Lotz approximation, and normally can be neglected for the ionization of the L shell, but ...
2000-02-01
Energy Technology Data Exchange (ETDEWEB)
A burner system particularly useful for downhole deployment includes a tubular combustion chamber unit housed within a tubular coolant jacket assembly. The combustion chamber unit includes a monolithic tube of refractory material whose inner surface defines the combustion zone. A metal reinforcing sleeve surrounds and extends the length of the refractory tube. The inner surface of the coolant jacket assembly and outer surface of the combustion chamber unit are dimensioned so that those surfaces are close to one another in standby condition so that the combustion chamber unit has limited freedom to expand with that expansion being stabilized by the coolant jacket assembly so that compression forces in the refractory tube do not exceed about one-half the safe compressive stress of the material; and the materials of the combustion chamber unit are selected to establish thermal gradient ...
1984-07-10
Target area chamber system design for the National Ignition Facility
International Nuclear Information System (INIS)
The National Ignition Facility (NIF) is a proposed Department of Energy facility which will contribute to the resolution of important Defense Program and inertial fusion energy issues for energy production in the future. The NIF will consist of a laser system with 192 independent beamlets transported to a target chamber. The target chamber is a multi-purpose structure that provides the interface between the target and the laser optics. The chamber must be capable of achieving moderate vacuum levels in reasonable times; it must remain dimensionally stable within micron tolerances, provide support for the optics, diagnostics, and target positioner; it must minimize the debris from the x-ray and laser light environments; and it must be capable of supporting external neutron shielding. The chamber must also be fabricated from a low neutron activation material. The fusion reaction in the target gives off ...
1994-06-19
UK PubMed Central (United Kingdom)
We performed a prospective study evaluating the 2-year success rate of extracapsular cataract surgery and posterior chamber IOL insertion performed in 610 eyes by an experienced surgeon in the Nepal...Full Text Available
1991-01-01
HPA - Radon Calibration Facilities
... Radon gas concentrations are measured using instruments with calibrations traceable to the UK National Physical Laboratory and PTB, Germany. The primary facility is a 43 m3 walk-in chamber accessed by an airlock. Radon gas is maintained at a level in this chamber that is ...
Foam Filled Muzzle Blast Reducing Device.
A device for reducing the muzzle blast and flash from large caliber guns is disclosed. A container having a plurality of internal chambers and baffle plates filled with an aqueous foam is mounted to the muzzle of the gun barrel. The foam and chambers co-o...
1982-01-01
UK PubMed Central (United Kingdom)
Purpose:To investigate the clinical usage of dose verification of Helical Tomotherapy plans by using 2D-array ion chambers, and to develop an efficient way to validate the dose delivered...Full Text Available
Chamberless residential warm air furnace design
Energy Technology Data Exchange (ETDEWEB)
This brief paper is an introduction to the concept of designing residential warm air furnaces without combustion chambers. This is possible since some small burners do not require the thermal support of a combustion chamber to complete the combustion process.
1996-07-01
THE RADIO JET INTERACTION IN NGC 5929: DIRECT DETECTION OF SHOCKED GAS
International Nuclear Information System (INIS)
We report on the discovery of kinematic shock signatures associated with a localized radio jet interaction in the merging Seyfert galaxy NGC 5929. We explore the velocity-dependent ionization structure of the gas and find that low-ionization gas at the interaction site is significantly more disturbed than high-ionization gas, which we attribute to a local enhancement of shock ionization due to the influence of the jet. The characteristic width of the broad low-ionization emission is consistent with shock velocities predicted from the ionization conditions of the gas. We interpret the relative prominence of shocks to the high density of gas in the nuclear environment of the galaxy and place some constraints of their importance as feedback mechanisms in Seyferts.
2010-03-10
Metal ion complexation by ionizable crown ethers
Energy Technology Data Exchange (ETDEWEB)
Research conducted since the last progress report includes the synthesis and characterization of twenty three novel proton-ionizable crown ether compounds. Metal ion complexation behavior of new and previously-synthesized proton-ionizable crown ether compounds has been probed by solvent extraction and transport across polymer-supported liquid membranes. The behavior of neutral polyether and proton-ionizable polyether ligands in polymeric membrane electrodes has been assessed. Studies of the use of proton-ionizable crown ethers for separation of lithium isotopes were initiated. Also, the thermodynamics of interactions between alkali metal cations and ionized crown ethers have been probed by titration calorimetry. 10 refs., 1 tab.
1989-09-01
Response of Baldwin-Farmer chamber at mammography energy
International Nuclear Information System (INIS)
(Dec 1977). United Kingdom Paliwal, BR Wochos, JF Wisconsin Univ., Madison
Multizone Modular Artillery Propelling Charge Studies.
... GUN PROPELLANTS, GUN CHAMBERS, PROPELLANT GRAINS, HOWITZERS, COMBUSTIBLE CARTRIDGE CASES, ZONE CHARGES. ...
1985-02-01
Conceptual design of the ATLAS EM muon chamber support structures
The conceptual design of the support structures of the EM muon chambers is presented. On each side of the detector the EM chambers are arranged in four layers: one layer of MDTs and the three layers of TGCs. The chambers are mounted on four individual wheel structures per side. The four wheels are inclined by 1.23% and suspended from two longitudinal beams parallel to the beam axis. In order to allow for the opening of the ATLAS detector the wheels can be displaced longitudinally over a distance of 6 m. In addition individual wheels can be separated from each other by up to 1 m for maintenance purposes.
1998-01-01
Combustible Metallic Igniter Casing for Tank Guns
... TANK GUNS, GUNS, CHAMBERS, IGNITERS, INTERIOR BALLISTICS, INTERNAL PRESSURE, COMBUSTIBLE CARTRIDGE CASES, METALS. ...
1991-11-01
Analog Gun (Selection of Consumable Cartridge Materials).
... Descriptors : *Combustible cartridge cases, *Polymers, *Test equipment, *Patents, Combustion chambers, Breech mechanisms, Gas generating ...
1975-09-02
Study of flows in a cyclone chamber
British Library Electronic Table of Contents (United Kingdom)
Parameters of the vortex air flow in an isothermal model of the cyclone chamber are studied. The effect of the air velocity in nozzles on the values and character of the distribution of pressure and tangential and longitudinal velocities of air in the chamber is determined. Numerical modeling of the flow is performed, and it is shown that numerical calculation by the k-w turbulence model is in agreement with experimental data.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The neutron detector is cased in a metal envelop and has one detector with a very sensitive fission chamber and a second detector with a fission chamber less sensitive that the first one and a boron coated ionisation chamber for reducing gamma radiation detection.
1992-06-12
Development of a retrofit coal combustor for industrial applications
Energy Technology Data Exchange (ETDEWEB)
In this first quarterly technical report for DOE Contract No. DE-AC22-87PC79654, a description of the background, technology, and application is provided. The design and fabrication of advanced combustion chambers were completed during this period. Initial testing on both the bare metal and refractory lined advanced chambers were initiated. The units were tested initially with gas but primarily with coal. A Pittsburgh No. 8 pulverized coal was used for these test activities. Both advanced chambers pulsed well.
1987-01-01
Combustion chamber layout for modern Otto engines
Energy Technology Data Exchange (ETDEWEB)
Since the most efficient way to improve fuel economy in the part-load range is to increase the compression ratio, emphasis is placed on combustion chambers allowing high compression ratios combined with low octane requirements. According to Porsche experience, many demands can be met in the simplest manner by locating the combustion chamber in the piston crown. This configuration offers various advantages over its counterpart installed in the cylinder head. 24 refs.
1981-10-01
Dosimetry limitations and a dose correction methodology for step-and-shoot IMRT
Energy Technology Data Exchange (ETDEWEB)
For the step-and-shoot intensity-modulated radiation therapy (IMRT) technique, the combination of high dose rate, multiple beam segments and low dose per segment can lead to significant differences between the planned dose and the dose delivered to the patient. In this technique, a dose delivery inaccuracy known as the 'overshoot' effect is caused by the dose servo control system. This typically occurs in the first and last beam segments and causes an over- and underdose, respectively. Some dose positional error in the segment sequence is also possible there. Commercial ionization chambers (RK-type) and radiographic Kodak films were used for the measurements. The reported results were obtained using the Pinnacle{sup 3}-V6.2 treatment planning system and a Varian Clinac 21 EX linear accelerator equipped with a 120-leaf Millennium MLC. The dose inaccuracy measurements were based on the comparison of the dose and profiles for ...
2006-02-07
International Nuclear Information System (INIS)
The goal of this work is to present a systematic Monte Carlo validation study on the clinical implementation of the enhanced dynamic wedges (EDWs) into the Pinnacle"3 (Philips Medical Systems, Fitchburg, WI) treatment planning system (TPS) and QA procedures for patient plan verification treated with EDWs. Modeling of EDW beams in the Pinnacle"3 TPS, which employs a collapsed-cone convolution superposition (CCCS) dose model, was based on a combination of measured open-beam data and the 'Golden Segmented Treatment Table' (GSTT) provided by Varian for each photon beam energy. To validate EDW models, dose profiles of 6 and 10 MV photon beams from a Clinac 2100 C/D were measured in virtual water at depths from near-surface to 30 cm for a wide range of field sizes and wedge angles using the Profiler 2 (Sun Nuclear Corporation, Melbourne, FL) diode array system. The EDW output factors (EDWOFs) for square fields from 4 to 20 cm wide were measured in virtual water using a small-volume ...
2009-01-21
Effects of small doses of ionizing radiation on human health
Energy Technology Data Exchange (ETDEWEB)
The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).
1997-12-01
Effects of small doses of ionizing radiation on human health
International Nuclear Information System (INIS)
The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).
1997-01-01
UK PubMed Central (United Kingdom)
Although skin is usually exposed during human exposures to ionizing radiation, there have been no thorough examinations of the transcriptional response of skin fibroblasts and keratinocytes...Full Text Available
2009-07-01
Untitled - NASA Technical Report Server (NTRS)
is 10 seconds for P-type silicon material,. TO ,. In ordkr to determine the effects of unbalanced ionization between the two ...
British Library Electronic Table of Contents (United Kingdom)
Abstract Ionizing radiation is a ubiquitous feature of the Cosmos, from exogenous cosmic rays (CR) to the intrinsic mineral radioactivity of a habitable world, and its influences on the emergence and persistence of life are wide-ranging and profound. Much attention has already been focused on the deleterious effects of ionizing radiation on organisms and the complex molecules of life, but ionizing radiation also performs many crucial functions in the generation of habitable planetary environments and the origins of life. This review surveys the role of CR and mineral radioactivity in star formation, generation of biogenic elements, and the synthesis of organic molecules and driving of prebiotic chemistry. Another major theme is the multiple layers of shielding of planetary surfaces from th...
2011-01-01
Ionization and recombination rates in non-Maxwellian plasmas
The ionization, excitation, and radiative recombination rates for highly stripped ions are cal- culated with Maxwellian and non-Maxwellian electron distribution functions of the type Cmexp(-vm/wm) (2<=m<=5) as encountered in laser-heated plasmas and certain types of turbulent plasmas. The direct-radiative-recombination rates are found to decrease by at most 30% as m is increased from 2 to 5. On the other hand, the ionization and excitation rates are found to be strongly reduced if the transition energy ? exceeds twice the local temperature kBTe. The effect of this on the distribution of energy levels and degrees of ionization in laser-produced plasmas could be important.
1986-08-01
The CDF II eXtremely Fast Tracker Upgrade
International Nuclear Information System (INIS)
The CDF II eXtremely Fast Tracker (XFT) is the trigger processor which reconstructs charged particle tracks in the CDF II central outer tracking chamber. The XFT tracks are also extrapolated to the electromagnetic calorimeter and muon chambers and are associated to electromagnetic clusters and muon stubs to generate trigger electron and muon candidates. The steady increase of the Tevatron instantaneous luminosity and the resulting higher occupancy of the chamber demanded an upgrade of the original system, which performed tracking only in the transverse plane of the chamber and was consequently affected by a significant level of fake tracks. In the upgraded XFT, tracking is reinforced by using additional data from the stereo layers of the chamber to reduce the level of fake tracks and to perform three-dimensional track reconstruction. A review of this upgrade is presented.
2007-10-21
Standards and guidances for limiting ionizing radiation exposure
Energy Technology Data Exchange (ETDEWEB)
This chapter is concerned with standards and guidances for limiting radiation exposures. It is divided into three sections, each of which has several parts. Section 1: Ionizing Radiation -- Standards and Guidances Applicable to the Public: Part A, Radiation Protection Standards; Part B, Environmental Radiation Standards; Part C, Exempt Levels of Radioactivity; Part D, Protective Action Guides for Accidents. Section 2: Ionizing Radiation -- Standards Applicable to the Workplace. Section 3: Medical and Other Standards.
1992-12-31
International Nuclear Information System (INIS)
Effect of single and chronic irradiation on factors of hamsters natural immunity such as complement, lysozyme and antibodies in norm and in the cestode invasion has been investigated. Significant phase changes in the complement activity level, lysozyme content and specific antibodies tite have been shown to occur in hamster blood under the influence of ionizing radiation. Cestode invasion in irradiated host organism increases the negative effect of ionizing radiation on the hamster immyne system.
1994-01-01
A simple, high efficiency, negative surface ionization source
Energy Technology Data Exchange (ETDEWEB)
A spherical-geometry, self-extraction negative ion source has been designed and fabricated. The source utilizes direct surface ionization to form negative ion beams resulting from interactions between high electron affinity gaseous elemental or molecular materials and a negatively biased, spherical-sector LaB{sub 6} surface ionizer maintained at {similar to}1300 K. The design features of this source and principles upon which the source is based are discussed in this report.
1992-04-01
Powder collection apparatus/method
Energy Technology Data Exchange (ETDEWEB)
Device for separating and collecting ultrafine atomized powder from the gas stream of a gas atomizing apparatus comprises a housing having an interior wall oriented at an angle relative to horizontal so as to form a downwardly converging, conical expansion chamber, an inlet conduit communicated to the expansion chamber proximate an upper region thereof for receiving the gas stream, and an outlet proximate a lower region of the expansion chamber. The inlet conduit is oriented at a compound inclined angle (with respect to horizontal) selected to promote separation and collection of powder from the gas stream in the expansion chamber. The compound angle comprises a first entrance angle that is greater than the angle of repose of the powder on the housing interior wall such that any powder accumulation in the inlet conduit tends to flow down the wall toward the outlet. The second angle is selected generally ...
1994-01-11
Energy Technology Data Exchange (ETDEWEB)
Operation safety and reliability are major guidelines in the design of city-gate units. Conventional natural gas heaters operate by a indirect mechanism, where liquid water is used to transfer heat by natural convection between the combustion chamber and the natural gas coil. In this work, the concept of vapor chamber is evaluated as an indirect gas heater. In a vapor chamber, liquid water is in contact with the heat source, and vaporizes. The vapor condenses in contact with the heat sink. A reduced scale model was built and tested in order to compare these two heating concepts where the combustion chamber was replaced by electrical cartridge heaters. This engineering model can operate either as a conventional heater or as a vapor chamber. The comparison between the concepts was done by inducing a controlled power to the cartridges and by measuring the resulting temperature ...
2005-07-01
Challenges in fabrication of 180deg magnet chamber
International Nuclear Information System (INIS)
180 deg magnet chamber is used in Folded Tandem Ion Accelerator for passage and 180 deg bending of ion beam. The chamber is placed between 180 deg terminal magnet (Electro-magnet), which is used for bending, and analysing the beams. Magnet with a particular magnetic field strength bends ions of only specified mass energy product through a precise path. There is also a space limitation in the direction of magnetic field. Both of them require the magnet chamber to be of a close tolerance. Accuracy of center distance between inlet and outlet port of the magnet chamber has to be at par with the concentricity of high energy and low energy beam line. To achieve this we started the fabrication of magnet chamber by following two methods: a) Circular rolling and bending of rectangular tube for 180 deg sector of magnet chamber b) Machining 180 deg sector in two half and ...
2006-11-01
Plasma chemistry in wire chambers
Energy Technology Data Exchange (ETDEWEB)
The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an {sup 55}Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For ...
1990-05-01
Energy Technology Data Exchange (ETDEWEB)
Simultaneous reduction of NO{sub x} and particulate emissions in a direct-injection diesel engine has been realized experimentally with a high squish combustion chamber. The purpose of this study is to investigate the effects of high squish combustion chamber on combustion process in detail. Engine CFD code FREC was used for the analysis. The results show the followings. (1) Compared with standard toroidal chamber, high squish chamber generates high turbulence due to strong squish and large expansion flow is caused in the cavity. (2) Rich and high-turbulence combustion, which forms ring area in the cavity under squish lip, continues during the combustion. (3) The high squish combustion chamber keeps fuel long in the cavity and less hid spreads out to the cold clearance volume. (4) For the condition of retarded injection timing, the effect of high squish is mainly observed at initial ...
1999-08-25
Influence of the humidity on leakage current under accelerated aging of polymer insulating materials
Energy Technology Data Exchange (ETDEWEB)
This paper describes the experimental results of accelerated aging tests conducted on three different types of polymer materials. Salt fog chamber tests were used to study the surface degradation modes for all materials. The work presented here was performed using a newly constructed fog chamber system that was able to control both chamber humidity and UV radiation. The changes in the surface morphology, material structure and leakage current were examined to study the influence of environmental humidity.
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
In this first quarterly technical report for DOE Contract No. DE-AC22-87PC79654, a description of the background, technology, and application is provided. The design and fabrication of advanced combustion chambers were completed during this period. Initial testing on both the bare metal and refractory lined advanced chambers were initiated. The units were tested initially with gas but primarily with coal. A Pittsburgh No. 8 pulverized coal was used for these test activities. Both advanced chambers pulsed well.
1987-12-31
True and measured outgassing rates of a vacuum chamber with a reversibly adsorbed phase
Energy Technology Data Exchange (ETDEWEB)
A pump down model for a vacuum chamber with a reversibly adsorbed phase is presented. The outgassing equation which predicts the variation of coverage at the wall surface of a vacuum chamber with time is derived. Then the measured and the true outgassing rates are defined. The theoretical measured outgassing rate shows only a very weak dependence for pumping speed. This prediction is opposite to the experimental result that the measured outgassing rate depends significantly on pumping speed. It is discussed that the experimental measured outgassing rate must be described as the product of the effective pumping speed and the measured pressure in the pumped chamber, in which the measured pressure is equivalent to the equilibrium pressure of the wall surface described by the equilibrium adsorption isotherm as a function of the shifted surface coverage {theta}-{delta}{theta} by a small coverage {delta}{theta} from the coverage ...
2000-03-01
Root Cause Analysis, Tank Fire Problem, M1A1 Main Battle ...
... ammunition is stored. Combustible cartridge cases could absorb moisture, swell, and not chamber properly. Additionally, moisture ...
1989-02-01
Energy Technology Data Exchange (ETDEWEB)
In order to realize simultaneous reduction of NO{sub x} and Particulate emissions, effects of combustion chamber geometry were investigated in a high speed direct-injection diesel engine. The reentrant combustion chambers with different throat diameter were compared in terms of engine performance, combustion characteristics and emissions such as NO{sub x}, particulate and THC. The phenomena of combustion process were also observed with endoscopic high speed photography. The results showed that when the throat diameter of a reentrant combustion chamber was reduced to an extent, NO{sub x} and particulate decreased simultaneously due to retarded injection timing and the intensified squish. (author)
1999-10-25
Microfluidic local perfusion chambers for the visualization and manipulation of synapses
UK PubMed Central (United Kingdom)
SummaryThe polarized nature of neurons as well as the size and density of synapses complicates the manipulation and visualization of cell biological processes that control synaptic...Full Text Available
2010-04-15
Some non-human animals may possess the ability to recall the "what", "where", and "when" of a single past event. We tested the hypothesis that male meadow voles possess the capacity to recall the "what", "where", and "when" of a single past event associated with mate selection in two experiments. Briefly, male voles were allowed to explore an apparatus that contained two chambers. One chamber contained a day-20 pregnant female (24 h prepartum). The other chamber contained a sexually mature female that was neither pregnant nor lactating (REF female). Twenty-four hour after the exposure, the males were placed in the same apparatus, which was empty and clean. At this time, the pregnant female would have entered postpartum estrus (PPE), a period of heightened sexual receptivity. Males initially chose and spent significantly more time investigating the chamber that originally housed the pregnant female (now ...
2007-07-26
Flame Temperatures and Internal Pressures of Pyrotechnic ...
... K. E. T,-us, "Clo:ei Chamber Burning Characteristics of Selected Liquid Monopropellants," 14th JANAP Combustion Meeting, CPIA Publication No. ...
1982-03-01
Chamber technology concepts for inertial fusion energy: Three recent examples
Energy Technology Data Exchange (ETDEWEB)
The most serious challenges in the design of chambers for inertial fusion energy (IFE) are 1) protecting the first wall from fusion energy pulses on the order of several hundred megajoules released in the form of x rays, target debris, and high energy neutrons, and 2) operating the chamber at a pulse repetition rate of 5-10 Hz (i.e., re-establishing, the wall protection and chamber conditions needed for beam propagation to the target between pulses). In meeting these challenges, designers have capitalized on the ability to separate the fusion burn physics from the geometry and environment of the fusion chamber. Most recent conceptual designs use gases or flowing liquids inside the chamber. Thin liquid layers of molten salt or metal and low pressure, high-Z gases can protect the first wall from x rays and target debris, while thick liquid layers have the added benefit of protecting ...
1997-02-27
Energy Technology Data Exchange (ETDEWEB)
A design is proposed for forming the rear screen of a chamber firebox at the point of aerodynamic projection and a design for attaching the pipes of the aerodynamic projection using girders linked with the screen by hinges and movable connections.
1982-01-01
Environmental trace gas analysis by proton-transfer-reaction mass spectrometry (PTR-MS)
International Nuclear Information System (INIS)
The work presented here demonstrates the ability of proton-transfer-reaction mass spectrometry (PTR-MS) to perform fast-response measurements of volatile organic compounds (VOCs) (including methanol, acetonitrile, acetaldehyde, acetone, PAN-type compounds, alpha- and beta-pinene, nopinone and pinonaldehyde) at the pptv level and its versatile applicability in the field of environmental trace gas analysis. Laboratory and field experiments including various calibration techniques and intercomparisons with other measurement techniques such as gas chromatography, atmospheric pressure chemical ionization and Fourier transformation infrared spectroscopy were performed providing a first characterization of the PTR-MS instrument performance (sensitivity, detection limit, precision, accuracy). Typically a detection limit (S/N=2) of 50 pptv for a 10 s signal integration time, a precision of 5 % and an accuracy in the range between 10 and 25 % were observed. Due to its ...
Energy Technology Data Exchange (ETDEWEB)
We have measured the K-shell ionization probability across the 6.06-MeV resonance in /sup 88/Sr(p,p/sub 0/) where the resonance width is large compared to the energy transferred to the electron. The results are found to agree quantitatively with the theory developed by Blair and Anholt. The effect of the time delay on the ionization probability, introduced by the nuclear scattering at the resonance energy, is discussed.
1982-09-01
A measurement of the cross section for electron impact ionization of Ar"2"+, Kr"2"+ and Xe"2"+
International Nuclear Information System (INIS)
The crossed electron-ion beams technique was used to measure absolute cross sections for single ionization of Ar"2"+, Kr"2"+ and Xe"2"+ ions at electron energies ranging from threshold to 2000 eV. In contrast to some previous measurements, the metastable contents of the ion beams were small even in the case of Xe"2"+. All measured cross section curves show significant contributions from excitation-autoionization and possibly direct ionization of inner-shell electrons. There is evidence for resonance-excitation-double-autoionization in the case of Xe"2"+. (author).
Toward a theory of the initiation of cancer by ionizing radiation: the twin doublet pair model
Models are proposed which explain the mechanism of action on a molecular level for the initiation of cancer by electrons or alpha particles. (ACR)
1980-01-01
International Nuclear Information System (INIS)
Portuguese Sep-Oct 1996 p. 571 Brazil Campos, Patricia Sao Paulo
Photoelectron resonance capture ionization (PERCI) is a soft and sensitive ionization method, based on the attachment of low-energy (<1 eV) photoelectrons to organic analyte molecules. PERCI has been developed in our laboratory for the real-time analysis of organic particles by mass spectrometry, and is employed here to monitor the heterogeneous reaction of ozone with oleic acid. Simplified identification of the reaction products is possible as a result of the soft nature of PERCI, giving predominantly the [M--H](-) ions. The major particle-phase products are identified as: 1-nonanal, nonanoic acid, 9-oxononanoic acid, and azelaic acid, consistent with proposed mechanisms. New insight into this well-studied heterogeneous reaction is gained as additional minor particle-phase products, consistent with the Criegee mechanism, are readily detected. PMID:15468105
2004-01-01
... that are hosts of tephritids (Diptera) and sweetpotatoes, Ipomea batatas (L.) Lam, at risk of carrying three ... ...
Extreme resistance of bdelloid rotifers to ionizing radiation
UK PubMed Central (United Kingdom)
Rotifers of class Bdelloidea are common invertebrate animals with highly unusual characteristics, including apparently obligate asexuality, the ability to resume reproduction after desiccation at any...Full Text Available
2008-04-01
Are There Enough Ionizing Photons to Reionize the Universe by z=6?
An estimate for the number of ionizing photons per baryon as a function of redshift is computed based on the plausible extrapolation of the observed galaxy UV luminosity function and the latest results on the properties of the escape fraction of ionizing radiation. It is found that, if the escape fraction for low mass galaxies (Mtot<10^{11}Msun) is assumed to be negligibly small, as indicated by numerical simulations, then there are not enough ionizing photons to reionize the universe by z=6 for the cosmology favored by the WMAP 3rd year results, while the WMAP 1st year cosmology is marginally consistent with the reionization requirement. The escape fraction as a function of galaxy mass would have to be constant to within a factor of two for the whole mass range of galaxies for reionization to be possible within the WMAP 3rd year cosmology.
2007-01-01
The central tracking detectors for D/O/
Energy Technology Data Exchange (ETDEWEB)
Three types of drift chambers are being constructed for the Fermilab D/O/ experiment. The construction and readout of these chambers stress good spatial resolution, good two hit separation, and dE/dx. A 106 MHz FADC system with hardware zero suppression is being constructed to readout this system. 8 refs., 12 figs., 1 tab.
1988-01-01
Phenomenological combustion model for a quiescent chamber diesel engine
Energy Technology Data Exchange (ETDEWEB)
A phenomenological model is presented for prediction of the combustion characteristics of a quiescent chamber diesel engine. Predictions with the model have shown acceptable agreement with a range of experimental data. The major physical processes controlling combustion have been characterized, and the dominant role of air entrainment and turbulent mixing confirmed quantitatively. 45 refs.
1981-10-01
Device for additional compaction of crushed coal loaded into a coke oven
Energy Technology Data Exchange (ETDEWEB)
This is a patent for a device to increase compaction of the loaded batch in a coking chamber that assures a balanced compaction of the batch from the upper to the bottom layer. The leveling rod has a device on the external end that causes the rod to shift vertically and bring pressure on the material and the pressing attachment. Opposite the loading hoppers of the coking chambers there are guides that ensure the rod will be sunk perpendicularly into the loaded material.
1980-03-26
Cooling device for rotors of multistage axial steam turbines
International Nuclear Information System (INIS)
The invention concerns an improvement of a cooling device for rotors of multistage axial steam turbines by providing in the first stage of each group of turbine stages a circulation loop connecting the wheel chamber on the inlet side of the rotor disc of the first stage with the wheel chamber on its outlet side. This is to cause the cooling effect not to be hampered by gap widths of the seal in the bottom range of the rotor blades changing during operation. Design particulars are described in detail. (UWI).
Combined gas/steam turbine process. Kombinierter Gas/Dampfturbinen-Prozess
Energy Technology Data Exchange (ETDEWEB)
A combined gas/steam turbine process includes a high-pressure furnace and a high pressure gasification unit with a mounted upstream of a combustion chamber there is a gas turbine with a waste heat system. Combustion heat which is not needed to heat the flue gas to combustion temperature is released from the furnace and transferred to ths combustion air going into the combustion chamber.
1991-01-31
Electrical breakdown at low pressure in the presence of a weak magnetic field
Energy Technology Data Exchange (ETDEWEB)
Electron trapping in crossed electric and magnetic fields is an important mechanism by which electrical discharges can develop in low pressure gases. The authors report observations of discharges produced by this mechanism around a spherical anode in two space simulation chambers, namely the Space Plasma Interaction Experiment (SPIE) at the University of Maryland, and the NASA-Lewis B-2 chamber. They have identified two types of discharges in these experiments. In the B-2 chamber, the breakdown takes the form of a runaway dischage with spherical topology, limited only by the ability of the power supply to provide the current. In the SPIE chamber this type of discharge also occurs, in addition to a low current toroidal discharge which is observed at higher magnetic fields. They present measurements of both types of discharge and show how the trapping effect of the magnetic field together with secondary ...
1990-05-01
Energy Technology Data Exchange (ETDEWEB)
This study tried to reduce NO{sub x} and particulate emissions simultaneously in a high speed direct-injection diesel engine. Fuel-rich combustion was used to reduce NO{sub x} emission at initial combustion stage and high turbulence combustion was used to reduce particulate emission at diffusion combustion stage. Experiments were carried out to investigate the effects of high squish combustion chambers with small throat on combustion process and exhaust emissions. Results showed that in the high squish combustion chamber, both NO{sub x} and particulate emissions reduced with retarded injection timing. Endoscopic high speed photography was employed to analyze experimental results. In the original combustion chamber at the early combustion stage, the high luminosity flame tended to spread out of the cavity. Fuel-rich mixture burned slowly over the piston crown. In the high squish combustion chamber, flame ...
1999-09-25
miR-9 and let-7g enhance the sensitivity to ionizing radiation by suppression of NF?B1
UK PubMed Central (United Kingdom)
The activation of nuclear factor-kappa B1 (NFκB1) in cancer cells may confer resistance to ionizing radiation (IR). To enhance the therapeutic efficiency of IR in lung cancer, we screened for...Full Text Available
2011-05-31
International Nuclear Information System (INIS)
The cross section database for electron impact excitation and electron impact ionization for hydrogen beam kinetic energies greater than 100 eV was considered, giving for each particular process a reference to a recommended publication of cross sections, as well as the accuracy or estimated accuracy. The work is motivated by the application of neutral beam injection in magnetic confinement devices, such as large tokamaks. 9 refs, 2 figs.
1989-07-01
Tumorigenic and tumoricidal actions of ionizing radiations
Energy Technology Data Exchange (ETDEWEB)
The book is divided into two approximately equal parts. The first four chapters are relatively lengthy and cover the basic principles of radiation biology, carcinogenesis and therapy, along with a brief introduction to radiological physics to orient the reader without background in this specialized related discipline. The remainder consists of twenty-four relatively brief chapters, each covering the radiation biology of a specific organ, tissue, or systems tissues, with emphasis on the tumorigenic and tumoricidal action of ionizing radiations.
1983-01-01
Theoretical transition energies, lifetimes and fluorescence yields of multiply ionized silicon
Energy Technology Data Exchange (ETDEWEB)
Theoretical x-ray transition energies, lifetimes and partial multiplet fluorescence yields are presented for all spectroscopic terms of electron configurations with a single K-shell vacancy and varying number of electrons in the L-shell and M/sub 1/-subshell for multiply-ionized silicon. 9 tables.
1982-01-01
The semiclassical approximation for L- and M-shell Coulomb ionization by heavy charged particles
International Nuclear Information System (INIS)
The semiclassical approximation with straight-line trajectories is applied to the Coulomb ionization of K, L and M shells by heavy charged particles. The calculational aspects are discussed in detail. Scaling relations for the experimentally relevant quantities are derived. The theoretical predictions are compared with experiment. The relation of the present work to the earlier results of the semiclassical approximation and partial-wave Born approximation is discussed in detail. (author).
Radioanalytical chemistry. Vol. 2
International Nuclear Information System (INIS)
This volume of the monograph covers the following topics: activation analysis, non-activation interaction analysis (elastic scattering of charged particles, absorption and backscattering of beta radiation and photons, radionuclide X-ray fluorescence analysis, thermalization, scattering and absorption of neutrons, use of ionization caused by nuclear radiation, use of ionization by alpha or beta radiation for the measurement of pressure, density and flow rate of gases), and automation in radioanalytical chemistry. (P.A.).
1989-01-01
Mechanisms of EBW HE initiation
Exploding bridgewire (EBW) initiation of high explosives (HE) has been used for many years without a clear understanding of the mechanisms involved. Evidence indicates that the shock pressures produced by the EBW may be insufficient for direct initiation and that the electric field about the wire at the time of burst ionizes the surface of the HE. We hypothesize that the ionization pre-sensitizes the HE so that a weak shock can then initiate a detonation wave. 13 refs., 7 figs.
1991-05-15
Organic molecules are a significant and highly varied component of atmospheric aerosols. Measurement of aerosol composition and improvements in our understanding of the complex chemistry involved in their formation and aging are being aided by innovations in soft ionization aerosol MS. (To listen to a podcast about this feature, please go to the Analytical Chemistry multimedia page at pubs.acs.org/page/ancham/audio/index.html.). PMID:21275431
2011-01-24
International Nuclear Information System (INIS)
A patent is claimed for the invention of a hardening (ionizing radiation resistance) process for MOS type components and CMOS or bipolar type components. The ionizing radiation effect on those systems is the electron-hole pair production, which induces interference phenomena. The MOS main structure is successively composed of a silicon substrate layer, a layer of an irradiation resistant material and a layer of partially monocrystalline silicon.
1988-12-09
Experimental research of spontaneous evolution from ultracold rydberg atoms to plasma
International Nuclear Information System (INIS)
The spontaneous evolution from ultracold Rydberg atoms to plasma is investigated in a caesium MOT by using the method of field ionization. The plasma transferred from atoms in different Rydberg states (n=22-32) are obtained experimentally. Dependence of the threshold time of evolving to plasma and the threshold number of initial Rydberg atoms on the principal quantum number of initial Rydberg states is studied. The experimental results are in agreement with hot-cold Rydberg-Rydberg atom collision ionization theory. (authors)
2008-04-01
Continuous control of ionization wave chaos by spatially derived feedback signals
In the positive column of a neon glow discharge, two different types of ionization waves occur simultaneously. The low-dimensional chaos arising from the nonlinear interaction between the two waves is controlled by a continuous feedback technique. The control strategy is derived from the time-delayed autosynchronization method. Two spatially displaced points of observation are used to obtain the control information, using the propagation characteristics of the chaotic wave.
1997-01-01
Cesium ion desorption ionization with Fourier transform mass spectrometry
International Nuclear Information System (INIS)
Cesium ions (Cs"+) are used for the production of the feed ions necessary to obtain Fourier transform mass spectra (FTMS). The molecule chosen for the initial study of this Cs"+ desorption ionization (DI-FTMS) was vitamin B-12 because of its nonvolatile, thermally labile character. 21 references.
Energy Technology Data Exchange (ETDEWEB)
A physical explanation is given for the positive differential voltage-current characteristic seen at low current in weakly ionized, low-pressure positive column discharges in argon/mercury gas mixtures. {copyright} {ital 1996 The American Physical Society.}
1996-07-01
Parametric Resonance Ionization Cooling and Reverse Emittance Exchange for Muon Collider
Energy Technology Data Exchange (ETDEWEB)
Two methods to cool muon beams deeply below the limit conventionally established for the ionization cooling are proposed. In Phase Ionization Cooling (PIC), the beam is focused at wedge absorber plates each half of particle oscillation period by imposing a weak parametric resonance along the beam path. The resonance growth of particle amplitude is surmounted by the ionization cooling. At optimum, such arrangement results in reduction of each of two transverse emittances by an order of value in addition to the preceding 6D ionization cooling. Next, resonance focusing and transverse cooling can be continued in the regime of a fast Reverse Emittance Exchange (REMEX). Here, the sign of the absorber wedge is opposite to PIC while the dispersion increased. REMEX to be accompanied by the bunch lengthening and acceleration in order to maintain the relative energy spread at an appropriate level. The limitations ...
2005-09-18
British Library Electronic Table of Contents (United Kingdom)
The photoelectron resonance capture ionization (PERCI) of cysteine (Cys) and small gas-phase neutral peptides that contain the Cys residue (Cys-Gly, g-Glu-Cys, and glutathione (g-Glu-Cys-Gly)) is reported. At an ionization energy less than 1eV two types of dissociative electron attachment ionization were observed for Cys: hydrogen atom loss, resulting in formation of the ion [Cys-H]-, and dissociation of the CH2-SH bond, resulting in formation of the ion [SH]-. The presence of these ions suggests that both the p*(-CO2H) and *(C-S) orbitals can act as low energy electrophores on Cys. This ionization trend was observed for the dipeptides Cys-Gly and g-Glu-Cys as well as glutathione, with evidence that dissociation of the CH2-SH bond in these peptides can also result in ions of the form [M-SH...
2009-01-01
We compare the predictions of four different algorithms for the distribution of ionized gas during the Epoch of Reionization. These algorithms are all used to run a 100 Mpc/h simulation of reionization with the same initial conditions. Two of the algorithms are state-of-the-art ray-tracing radiative transfer codes that use disparate methods to calculate the ionization history. The other two algorithms are fast but more approximate schemes based on iterative application of a smoothing filter to the underlying source and density fields. We compare these algorithms' resulting ionization and 21 cm fields using several different statistical measures. The two radiative transfer schemes are in excellent agreement with each other (with the cross-correlation coefficient of the ionization fields >0.8 for k 0.6 for k < 1 h/Mpc). When used to predict the 21cm power spectrum at different times during ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
The experimental survey about the heat transfer between the working fluid and the combustion chamber wall with a direct injection diesel engine has shown the production of a soot layer with increasing loads on the combustion chamber wall. Because the combustion process of methanol occurs without the formation of wall deposits, the same engine spark ignitioned with methanol at the same conditions has shown a higher heat transfer coefficient. Because the heat losses do not only depend on the heat transfer coefficient but also on the driving temperature difference between the working fluid and the combustion chamber wall, the methanol engine with corresponding process management showed lower heat losses than the diesel engine at nearly the same load. (orig./HW)
1994-04-01
Energy Technology Data Exchange (ETDEWEB)
Based on the CFD-code FLUENT trademark, theoretical studies were conducted of the influences of incineration chamber geometry (direct, countercurrent and center flow) on the combustion process. The boundary conditions, e.g., the thermal input and the waste grate, were kept constant. Close attention was paid to the distribution of flow, spe-cies, and temperatures. In addition, the influence of a dis-placement body at the end of the combustion chamber was tested. The variation of different wall materials and the prediction of problem areas concerning corrosion, slagging, and contamination completed the studies. Close to the chamber walls, high CO-concentrations may indi-cate corrosion; particle flow may indicate where contami-nation, slagging or erosion could occur. (orig.)
2001-01-01
Stability and disturbance of large dc superconducting magnets
Energy Technology Data Exchange (ETDEWEB)
This paper addresses the stability aspects of several successful dc superconducting magnets such as large bubble chamber magnets, and magnets for the Mirror Fusion Test Facility and MHD Research Facility. Specifically, it will cover Argonne National Laboratory 12-Foot Bubble Chamber magnets, the 15-foot Bubble Chamber magnets at Fermi National Laboratory, the MFTF-B Magnet System at Lawrence Livermore National Laboratory, the U-25B Bypass MHD Magnet, and the CFFF Superconducting MHD magnet built by Argonne National Laboratory. All of these magnets are cooled in pool-boiling mode. Magnet design is briefly reviewed. Discussed in detail are the adopted stability critera, analyses of stability and disturbance, stability simulation, and the final results of magnet performance and the observed coil disturbances.
1981-11-11
Radiation streaming analysis of horizontal penetrations in calandria vault of TAPP-3, 4
International Nuclear Information System (INIS)
This paper consists the radiation streaming analysis of Horizontal penetrations in Calandria Vault of 540 MWe PHWR. There are total 19 penetrations, penetrating east and west walls of calandria vault of 540 MWe PHWR. These penetrations are provided to accommodate ion chambers. HFUs and SDS - 2. Penetrations described here are not present in 220 MWe units except for ion chamber penetrations. As these penetrations are in accessible area, a detailed analysis has been carried out to find out the neutron and gamma dose rates around these penetrations when reactor is operating. Analysis has been carried out using computer code DOT-III and MCNP. Predictions by this method compare well with the measurements at ion chamber locations at KGS-1,2. (author)
2006-11-13
Intake system for direct fuel injection diesel engine
Energy Technology Data Exchange (ETDEWEB)
An intake system is described for a direct fuel injection diesel engine having a cylinder block, at least one cylinder in the cylinder block, a piston in the cylinder having a recess on a top surface thereof, a cylinder head mounted on the cylinder block on top of the cylinder, a fuel injector adapted to directly inject fuel into a combustion chamber formed between the lower side of the cylinder head and the recess on the top surface of the piston, and below the injector, and a single exhaust passage opening to the combustion chamber at a location near the injector, the intake system comprising first and second intake passages in the cylinder head, the first and second intake passages are independent of each other and adapted to introduce air into the combustion chamber. The controller means are coupled to the second intake passage for controlling the flow of air therethrough.
1987-08-25
British Library Electronic Table of Contents (United Kingdom)
Flame propagating through zirconium particle cloud in a small-scale vertical rectangle chamber was investigated experimentally. In the experiments, the zirconium quoted 99% purity was used and the diameter of particles was distributed 1?22 ?m. The zirconium dust was dispersed into the chamber by air flow and ignited by an electrode spark. A high-speed video camera was used to record the images of the propagating flame. Micro-thermocouples, schlieren optical system and microscopic lens were used to obtain temperature profiles and flame structure, respectively. Based on the experimental results, flame propagation characteristics and flame structure of zirconium particle cloud were analyzed. The propagation velocity of the flame is quite slow in the initial 14 ms and then accelerates to maxim...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
An apparatus for non-invasively inspecting an object, such as an item of luggage, for explosives material is described. It comprises a multi-channel thermal neutron inspection system having a plurality of neutron irradiation chambers. Simultaneous operation of several channels increases the maximum system throughput several times. Each chamber has a lithium neutron source which is stimulated to neutron production by a proton beam. Beam switching magnets are energised by pulsing to divert a common proton beam to each source in turn. The initial beam is generated by a radio frequency quadrupole accelerator. The advantages of this system are very low residual source activity and controllable neutron production thereby minimising safety hazards. The irradiation chamber may contain several different gamma ray detectors to identify the elements present in explosives material. In addition, a neutron radiography imaging means may ...
1991-10-02
Energy Technology Data Exchange (ETDEWEB)
The unburned HC in a direct-injection diesel engine is a cause of exhaust odor and SOF emission. Reduction of HC by changing the injection nozzle specifications was attempted in previous studies. In this study, some experiments in which the mixture formation was varied by using different hole diameters in a multihole nozzle and spray angles to the combustion chamber wall have been conducted. When the diameter of injection holes, which influences the fuel adhering to on the cylinder head walls and the combustion chamber wall, becomes smaller, the HC emission in the idling condition, HC deviation from cylinder to cylinder and HC increase with long idling time are decreased. The same effects were obtained by decreasing the diameter of all holes and by injecting the spray downward to the combustion chamber. 13 refs., 13 figs., 1 tab.
1996-02-25
Bongs - a new fertilizer plant
Energy Technology Data Exchange (ETDEWEB)
In an attempt to overcome inadequacies perceived in the approach to providing energy to village communities using the conventional Khadi and Village Industries Commission biogas plant as well as the Janata model, a biogas digester has been developed suitable for a farmer having only one hectare of land. The information on gas yields and other data from a variety of substrates in a laboratory digester are presented. The digester itself consists of a chamber underground into which the influent flows through a channel. Gas is collected in a dome which constitutes the upper part of the digestion chamber and is maintained under pressure by water. The dome can be made of any suitable material such as plastic, ferrocement and brick and mortar. The upper part of the chamber itself is exposed to sun light which enhances microbial growth. Water which surrounds the dome ensures a minimum of temperature variation. 3 references.
1981-01-01
Energy Technology Data Exchange (ETDEWEB)
Several proposals have been made on the method of calculating generation of formaldehyde released from plywood. In calculating generation per hour of a volatile organic compound of adhesives or coatings using a chamber method, such models are frequently used that the generation is largest when the specimen is exposed in the chamber and that the generation attenuates with lapse of time. In the meantime, a number of studies for calculating formaldehyde generation from construction materials are often those determining a specific quantity of generation in a stationary state, while few studies are the observation of time series variation from immediately after the exposure into the chamber. Accordingly, the subject studies used lauan plywood as the samples and examined the method of calculating the change with lapse of time of the formaldehyde generation. (translated by NEDO)
2000-01-05
Wire pad chamber for LHCb muon system
2000-003 Wire pad chambers (WPC) have been proposed for the outer Region 4 of the LHCb Muon System. These are double gap MWPCs with small wire spacing allowing to obtain 99% detection efficiency in a 20 ns time window. The chambers have a rectangular shape with the vertical dimension from 20 cm in Station 1 to 30 cm in Station 5. The horizontal dimensions will be different with the maximal size of 3 meters in Station 5. The wires are in the vertical direction. The short wire length allows to use small wire spacing needed for high time resolution. Also, this helps to obtain the uniform gas gain over the whole chamber area. The WPC has one row of the wire pads formed by grouping wires in separate readout channels. Four WPC prototypes have been built at PNPI and tested in the PS beam at CERN. Here we report on the results from these tests. Also, the results of simulation of the WPC performance are presented.
2000-01-01
Energy Technology Data Exchange (ETDEWEB)
Simplifying hypotheses are required when combustion and aerodynamic phenomena are considered simultaneously. In this paper, a turbulent combustion model is proposed, in which the combustion chemistry is reduced to a single reaction. In this way, only two variables are needed to describe the problem and combustion can be characterized by the consumption of one of the two reactive species. In a first step, the instantaneous consumption rate is obtained using the Lagrangian form of the mass fraction equation of the species under consideration, and by considering the equilibrium state only. This state is determined in order to preserve the consistency with results that should be obtained using a complete kinetics scheme. In a second step, the average rate is determined using the instantaneous consumption term and a probabilistic density function. This model was tested on various configurations and in particular on an experimental main chamber and on a reheating ...
1996-12-31
Ozone produced by chemonuclear generation
International Nuclear Information System (INIS)
Processes and apparatus are disclosed for generation of radioisotope contaminant fission fragment free ozone from oxygen containing streams by chemonuclear irradiation accomplished by passing the stream past high energy radiation sources placed in sealed chambers.
UK PubMed Central (United Kingdom)
Mouse models for the study of autistic-like behaviors are increasingly needed to test hypotheses about the causes of autism, and to evaluate potential treatments. Both the automated 3-chambered...Full Text Available
2008-11-21
Investigation of Residue and Coating Stoichiometry on 120-mm Combustible Cartridge Cases.
An investigation was conducted to determine the cause of coating residue found in the test gun chambers during qualification firing of 120-mm combustible cartridge case (CCC) ammunition for the MlAl/A2 main battle tank. The CCC is coated with a clear epox...
2000-01-01
Energy Technology Data Exchange (ETDEWEB)
To carry out studies on the radon behavior under controlled and stable conditions it was designed and constructed a system that consists of two parts: a container of mineral rich in Uranium and an experimentation chamber with radon united one to the other one by a step valve. The container of uranium mineral approximately contains 800 gr of uranium with a law of 0.28%; the radon gas emanated by the mineral is contained tightly by the container. When the valve opens up the radon gas it spreads to the radon experimental chamber; this contains 3 accesses that allow to install different types of detectors. The versatility of the system is exemplified with two experiments: 1. With the radon experimental chamber and an associated spectroscopic system, the radon and two of its decay products are identified. 2. The design of the system allows to couple the mineral container to other experimental geometries to demonstrate this fact ...
1991-10-15
UK PubMed Central (United Kingdom)
BackgroundWith the phasing out of ozone-depleting substances in accordance with the United Nations Montreal Protocol, phosphine remains as the only economically viable fumigant for...Full Text Available
Combustion system for dual fuel engine
Energy Technology Data Exchange (ETDEWEB)
This patent describes in an dual gas-liquid fuel four cycle engine having cylinders and wherein each cylinder is operatively connected thereto and each cylinder has a piston, two inlet valves, two exhaust valves and a first liquid fuel injector. It comprises: at least one fuel torch cell operatively connected to at least one cylinder, the torch cell having a torch cell nozzle at one end thereof and the other end having appropriate means to connect the torch cell to a fuel supply, a second fuel injector mounted in the torch cell at a predetermined angle to an axis of the torch cell, the torch cell defining an auto-ignition chamber, the second fuel injector being in operative communication with the auto-ignition chamber by an injector nozzle passageway, the injector nozzle passageway entering the auto-ignition chamber at a predetermined angle relative to the axis, and a torch nozzle passage connecting the auto-ignition ...
1990-10-30
A numerical investigation of the aerodynamics of a furnace with a movable block burner
Scientific Electronic Library Online (English)
Abstract in english In this work the air flow in a furnace was computationally investigated. The furnace, for which experimental test data are available, is composed of a movable block burner connected to a cylindrical combustion chamber by a conical quarl. The apertures between the movable and the fixed blocks of the burner determine the ratio of the tangential to the radial air streams supplied to the furnace. Three different positions of the movable blocks were studied at this time. A thr (more) ee-dimensional investigation was performed by means of the finite volume method. The numerical grid was developed by the multiblock technique. The turbulence phenomenon was addressed by the RNG k-epsilon model. Profiles of the axial, tangential and radial velocities in the combustion chamber were outlined. The map of the predicted axial velocity in the combustion chamber was compared with a map of the experimental axial velocity. ...
2007-06-01
British Library Electronic Table of Contents (United Kingdom)
We have demonstrated that, with simple pH adjustment, volatile drugs such as methamphetamine, amphetamine, 3,4-methylenedioxymethamphetamine (MDMA), ketamine, and valproic acid could be analyzed rapidly from raw biofluid samples (e.g. urine and serum) without dilution, or extraction, using atmospheric pressure ionization. The ion source was a variant type of atmospheric pressure chemical ionization (APCI) that used a dielectric barrier discharge (DBD) to generate the metastable helium gas and reagent ions. The sample solution was loaded in a disposable glass pipette, and the volatile compounds were purged by nitrogen gas to be reacted with the metastable helium gas. The electrodes of the DBD were arranged in such a way that the generated glow discharge was confined within the discharge tub...
2009-01-01
International Nuclear Information System (INIS)
A high-precision Li isotope analysis was developed for determining the Li"+ ion emitted from lithium phosphate as an ion source material by a Re double-filament ionization method in the thermal ionization mass spectrometry. In this method, Li isotopic fractionation is distinctly less sensitive to the filament temperature than those in the previous methods, and stable and high ion beam intensity of more than 8 x 10"-"1"1 A for "7Li is obtained. These advantages in determining the "7Li/"6Li ratio result in the analytical reproducibility of 0.26 per mille (1#sigma#). Furthermore, the sample preparation is simple and the low temperature (850degC) required by this method ensures the analysis of the isotopic composition of small amounts of Li with less influence of Li contamination to the sample, compared with the previous methods. (author).
Photoelectron resonance capture ionization mass spectrometry of fatty acids in olive oil
British Library Electronic Table of Contents (United Kingdom)
Photoelectron resonance capture ionization (PERCI) mass spectrometry has been developed for the direct online analysis of organics, including lipids. Analysis is conducted without the need for sample preparation or chemical derivatization such as methylation, foregoing the use of harmful or toxic chemicals. PERCI is currently being adapted towards the analysis of edible oils. Herein, as a proof of principle of the simplicity and potential utility of this method towards the analysis of edible oils, we present the analysis of the prevalent fatty acids (FA) in Tuscan extra-virgin olive oil along with triolein and linolenic acid (LNA) standards. Ionization of olive oil results in little fragmentation of the prevalent FA, which are measured as their molecular ions, [FA-H]-. The relative concent...
2006-01-01
Measurement of electron-impact single-ionization cross sections of Ar"8"+
International Nuclear Information System (INIS)
A crossed-electron-ion-beam experiment was used to measure the total ionization cross section for Ar"8"+ in the energy range from 50 to 600 eV. The present results are roughly in agreement with the previous measurements of Defrance et al. [Nucl. Instrum. Methods Phys. Res. B 23, 256 (1987)] above 450 eV. However, the present measurements show a significant contribution below the threshold for direct ionization. The present measurements agree with the distorted-wave calculations of Pindzola et al. [Phys. Rev. A 41, 1375 (1990)] when 3% of the incident ion beam is assumed to be in metastable states and excitation autoionization from metastable states is included.
British Library Electronic Table of Contents (United Kingdom)
Abstract We use Smoothed Particle Hydrodynamics to simulate the formation of a massive (106-M-) stellar cluster system formed from the gravitational collapse of a turbulent molecular cloud. We investigate the hierarchical clustering properties of our model system and we study the influence of the photoionizing radiation produced by the system's multiple O-type stars on the evolution of the protocluster. We find that dense gas near the ionizing sources prevents the radiation from eroding the filaments in which most of the star formation occurs and that instead, ionized gas fills pre-existing voids and bubbles originally created by the turbulent velocity field.
2011-01-01
Ion-induced M X-ray emission from heavy lanthanides
International Nuclear Information System (INIS)
Thick targets of several heavy lanthanide (Ho-Lu) compounds were bombarded by protons and "3He ions of 3 MeV/amu, and M_#alpha# and M_#beta# X-rays were measured with a crystal spectrometer. Ionization probabilities of the N-shell for zero impact parameter were obtained from the X-ray intensity ratio for proton and "3He ion impacts. A shell dependence of the ionization probability was found in a scaling plot. X-ray spectra of lanthanide compounds were compared and no chemical effect was observed. This result is considered to be due to the fact that the main component of M_#alpha# and M_#beta# lines is for radiative transition after the refilling of the 4f orbit (3d"-"14f"n"+"1 #-># 4f"n) where n denotes the number of 4f electrons of the target atom before ionization. (orig.).
1987-12-01
British Library Electronic Table of Contents (United Kingdom)
High molecular weight products of the ozonolysis reaction of particle-phase 9-octadecenoic acid (oleic acid) have been studied by photoelectron resonance capture ionization (PERCI) mass spectrometry (MS). Oleic acid particles ( Formula Not Shown , Formula Not Shown ) were reacted with ozone (1.8x10-4atm) in a flow reactor at reaction times of 8 and 23s. Particles were sampled on-line with a differentially pumped particle inlet and chemically analyzed by PERCI-MS. PERCI is a soft ionization method that permits the direct measurement of relatively high molecular weight compounds, facilitating molecular identification. In addition to cyclic oxygenates, such as secondary ozonides and geminal diperoxides that were reported previously, we demonstrate the formation of polymers at the particle sur...
2006-01-01
Energy Technology Data Exchange (ETDEWEB)
The proton and deuteron spectra following resonant multiphoton ionization of H{sub 2} and HD at 193 nm through the {ital E},{ital F} state have been studied at power densities of 10{sup 10} W/cm{sup 2}. Our results show that the intermediate state induces competition between 3(2+1)-photon ionization, dissociation, and dissociative ionization channels. We find that the competition depends on the specific vibrational and rotational levels excited in the intermediate state. At the same time, the mere presence of this bound intermediate state renders these three-photon fragmentation channels so efficient that higher-order fragmentation processes, such as Coulomb explosions requiring many more photons, are not observed.
1991-04-01
Active hydrogen by chemical ionization mass spectrometry.
A means of determination of a ctive hydrogen of hydroxyl, carboxyl, sulfhydryl, amino, amido and sulfonamido groups by chemical ionization mass spectrometry using ammonia and trideuterioammonia as reagent gases is described. The method is based on exchange of active hydrogen for deuterium occurring during the chemical ionization process using trideuterioammonia, with comparison of m/z for ammonium adduct [M + NH1]+ and trideuterioammonium adduct [M--nH + nD + ND4]+, or of protonated molecular ion [M + H]+ and deuteronated molecular ion [M--nH + nD + D]+ yielding the number of active hydrogens. Applications have been made to several classes of biologically important compounds. PMID:427257
1979-01-01
Selective mining of bedded uranium deposits using high-pressure waterjet equipment
International Nuclear Information System (INIS)
High-pressure waterjet equipment is now technically and economically viable and commercially available for the following mining and construction applications: (1) drilling soft to medium-hard rock; (2) slotting, discing, chambering, and reaming in all types of rock. However, additional field experience is needed to prepare detailed economic evaluations. Extensive development of new explosives techniques and blasting methods will be required to take full advantage of the unique waterjet hole slotting, discing, and chambering capabilities.
1981-12-04
Pneumatic forms for construction of underground structures
Energy Technology Data Exchange (ETDEWEB)
Discusses design of unconventional pneumatic forms for construction of monolithic liners in mine roadways driven by drilling and blasting. The forms were developed for construction of the municipal subway in Leningrad. They were successfully tested in the Pavlogradugol' mines for construction of chambers situated at shaft bottom at depths of 420 m. The chambers were situated in unstable rock strata. A set of pneumatic forms consisted of 4 to 7 units, each 0.4 m thick and 1.2-2.2 m long. Air pressure was 0.03 MPa, installation time was about 20 min. Service life of pneumatic forms ranged from 3 to 4 years.
1991-08-01
Energy Technology Data Exchange (ETDEWEB)
Objective: Optimization and testing of a high temperature combustion chamber for burning coal gas and conventional fuels natural gas or fuel oil. Coal gas is not available in such quantity for testing a full scaled combustion chamber. Therefore the design of the combustion chamber is based of experimental results from model tests and numerical solution procedures. Working program: (1) Analytical model for burning coal gas implemented in an existing computational fluid dynamics (CFD) code. (2) Three-dimensional calculations of a full scaled combustion chamber with a CFD code for flows accompanied by combustion and chemical reaction. (3) Improvement of measuring method for determination of flame temperature and concentration. (4) Temperature and concentration profil measuring in a full scaled combustion chamber by operating with natural gas or fuel oil. Results: An analytical model ...
1994-03-01
Method of combustion for dual fuel engine
Energy Technology Data Exchange (ETDEWEB)
Apparatus and a method of introducing a primary fuel, which may be a coal water slurry, and a high combustion auxiliary fuel, which may be a conventional diesel oil, into an internal combustion diesel engine comprises detecting the load conditions of the engine, determining the amount of time prior to the top dead center position of the piston to inject the main fuel into the combustion chamber, and determining the relationship of the timing of the injection of the auxiliary fuel into the combustion chamber to achieve a predetermined specific fuel consumption, a predetermined combustion efficiency, and a predetermined peak cylinder firing pressure. 19 figures.
1993-12-21
LPP combustion control for IC engine with abnormal combustion
Energy Technology Data Exchange (ETDEWEB)
An LPP ignition timing control is described for an internal combustion engine including a combustion chamber, means effective to ignite a combustible charge within the combustion chamber and power output apparatus including a rotating crankshaft driven in response to the expansion of the combustible charge following the ignition thereof and having a predefined TDC rotational reference position, the engine being of the type having a normal combustion mode characterized by combustion pressure peaks compatible with closed loop LPP ignition timing control and an abnormal combustion mode which may not be so compatible.
1986-06-24
FFTF (Fast Flux Test Facility) Reactor Characterization Program: Absolute Fission-rate Measurements
Energy Technology Data Exchange (ETDEWEB)
Absolute fission rate measurements using modified National Bureau of Standards fission chambers were performed in the Fast Flux Test Facility at two core locations for isotopic deposits of {sup 232}Th, {sup 233}U, {sup 235}U, {sup 238}U, {sup 237}Np, {sup 239}Pu, {sup 240}Pu, and {sup 241}Pu. Monitor chamber results at a third location were analyzed to support other experiments involving passive dosimeter fission rate determinations.
1981-05-01
FFTF (FAST FLUX TEST FACILITY) REACTOR CHARACTERIZATION PROGRAM ABSOLUTE FISSION RATE MEASUREMENTS
Energy Technology Data Exchange (ETDEWEB)
Absolute fission rate measurements using modified National Bureau of Standards fission chambers were performed in the Fast Flux Test Facility at two core locations for isotopic deposits of {sup 232}Th, {sup 233}U, {sup 235}U, {sup 238}U, {sup 237}Np, {sup 239}Pu, {sup 240}Pu, and {sup 241}Pu. Monitor chamber results at a third location were analyzed to support other experiments involving passive dosimeter fission rate determinations.
1981-05-01
A high-sensitivity scintillation chamber for radon in gas
Energy Technology Data Exchange (ETDEWEB)
A large scintillation chamber of 6.7 l volume for direct radon concentration measurements in gas is presented. With two 5 in. photomultipliers on opposite sides, working in coincidence, a concentration as low as about 0.5 mBq/l is detectable with 10% standard deviation after 1000 min measuring time. With the achieved background count rate of 0.42 counts/min and the counting efficiency of 0.607 for [sup 222]Rn and its progenies the absolute minimal detectable specific activity is reached with 0.17 mBq/l at about 12 000 min. The method to determine this minimum detectable activity is outlined. ((orig.))
1994-06-15
DoseWatchers - A computer based X ray dose monitoring project in paediatric radiology
International Nuclear Information System (INIS)
Full text: Introduction. Children, especially premature infants and neonates, are at a much higher risk to obtain an X ray induced disturbance of life - particularly cancer. On the one hand this is due to their longer life expectancy and on the other hand it is due to their higher cell proliferation rate. The paediatric radiology unit of the Inselspital Bern recently installed some of the most advanced X ray equipment nowadays available. It is based on the two latest digital technologies: double read computed radiography (CR) and direct digital radiography (DR). Only the implementation of these digital radiography systems permits the digital acquisition and additionally the analysis of acquired data. The systematic analysis of large amounts of biometric data and exposition data is the basis for further dose reduction and a systematic quality control (QC). Patients are increasingly critical concerning radiation exposure - especially parents regarding their children. Besides an ...
2006-11-13
Energy Technology Data Exchange (ETDEWEB)
Various characteristics of F stars are described. The spectra of F stars are analyzed, and it is determined that the spectral types are based on ionization levels. The CNO cycle and rotation speeds of the stars are examined. The period-luminosity relation of pulsators is studied, and specific examples of unstable pulsators are presented.
1987-02-01
Targeted nanoparticles that deliver a sustained, specific release of paclitaxel to irradiated tumors
UK PubMed Central (United Kingdom)
To capitalize on the response of tumor cells to ionizing radiation, we developed a controlled-release nanoparticle drug delivery system using a targeting peptide that recognizes a radiation-induced...Full Text Available
2010-06-01
UK PubMed Central (United Kingdom)
A fast and sensitive LC-ESI-MS method is described for the comparative quantification of 16 estrogen metabolites based on the derivatization of estrogens with a novel derivatizing reagent, N-methyl-nicotinic...Full Text Available
2008-07-15
Spectrophotometry of H II regions in the spiral galaxy M101
Energy Technology Data Exchange (ETDEWEB)
Spectral line intensity data are presented for ionized hydrogen regions in the giant spiral galaxy M101. The influence of interstellar extinction is assessed and electron temperatures of the gas clouds are derived.
1981-04-01
Numerical simulations predict that a large number of baryons reside in intergalactic space at temperatures between 10^5-10^7 K. Highly-ionized metals, such as O VII and O VIII, are good tracers of this ``warm-hot intergalactic medium'', or WHIM. For collisionally-ionized gas, the ionization fraction of each ion peaks at some particular temperature (``peak temperatures''), so different ions can therefore trace the IGM at different temperatures. We performed a hydrodynamic simulation to study the metal distributions in the IGM. We then draw random lines-of-sight across the simulated region and synthesize resonance absorption line spectra in a similar way to simulating the Ly-alpha forest. By studying the distribution functions of H- and He-like O, Si and Fe in a collisionally-ionized IGM and comparing with semi-analytic results based on the Press-Schechter formalism, we find: (1) ions with higher peak ...
2001-01-01
UK PubMed Central (United Kingdom)
AbstractBackgroundIonizing radiation (IR) initiates intracellular oxidative stress through enhanced formation of reactive oxygen species (ROS) that attack DNA leading...Full Text Available
2010-05-01
Probing the Mechanisms of an Air Amplifier using a LTQ-FT-ICR-MS and Fluorescence Spectroscopy
UK PubMed Central (United Kingdom)
We report the first quantitative assessment of electrosprayed droplet/ion focusing enabled by the use of a voltage-assisted air amplifier between an electrospray ionization emitter and a hybrid...Full Text Available
2007-11-01
Motion management with phase-adapted 4D-optimization
UK PubMed Central (United Kingdom)
Cancer treatment with ionizing radiation is often compromised by organ motion, in particular for lung cases. Motion uncertainties can significantly degrade an otherwise optimized treatment plan....Full Text Available
2010-09-07
UK PubMed Central (United Kingdom)
Our goal was to determine whether chlorpyrifos oxon, dichlorvos, diisopropylfluorophosphate (DFP), and sarin covalently bind to human albumin. Human albumin or plasma was treated with organophosphorus...Full Text Available
2007-02-15
K-shell ionization of Al, V, Fe, Cu, Y, Mo, Ag, and Sn by 1-5-MeV alpha-particle bombardment
International Nuclear Information System (INIS)
(Jan 1974). United States McKnight, RH Thornton, ST Karlowicz, RR
Identification of novel DNA repair proteins via primary sequence, secondary structure, and homology
UK PubMed Central (United Kingdom)
BackgroundDNA repair is the general term for the collection of critical mechanisms which repair many forms of DNA damage such as methylation or ionizing radiation. DNA repair has...Full Text Available
Evidence for a lack of DNA double-strand break repair in human cells exposed to very low x-ray doses
UK PubMed Central (United Kingdom)
DNA double-strand breaks (DSBs) are generally accepted to be the most biologically significant lesion by which ionizing radiation causes cancer and hereditary disease. However, no information on the...Full Text Available
2003-04-29
DNA sequencing using biotinylated dideoxynucleotides and mass spectrometry
UK PubMed Central (United Kingdom)
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MS) has been explored widely for DNA sequencing. The major requirement for this method is that the DNA sequencing fragments...Full Text Available
2001-11-01
UK PubMed Central (United Kingdom)
A compensatory response, viz. in vivo recovery from radiation damage to mitochondria, occurs in preclimacteric pear fruits (Pyrus communis L.) treated with ionizing...Full Text Available
1968-07-01
Biological Research for Radiation Protection
International Nuclear Information System (INIS)
The work scope of 'Biological Research for the Radiation Protection' had contained the research about ornithine decarboxylase and its controlling proteins, thioredoxin, peroxiredoxin, S-adenosymethionine decarboxylase, and glutamate decarboxylase 67KD effect on the cell death triggered ionizing radiation and H_2O_2(toxic agents). In this study, to elucidate the role of these proteins in the ionizing radiation (or H_2O_2)-induced apoptotic cell death, we utilized sensesed (or antisensed) cells, which overexpress (or down-regulate) RNAs associated with these proteins biosynthesis, and investigated the effects of these genes on the cytotoxicity caused by ionizing radiation and H_2O_2(or paraquat). We also investigated whether genisteine(or thiamine) may enhance the cytotoxic efficacy of tumor cells caused by ionizing radiation (may enhance the preventing effect radiation or paraquat-induced damage) because ...
Advanced MRI Methods for Assessment of Chronic Liver Disease
UK PubMed Central (United Kingdom)
MRI plays an increasingly important role for assessment of patients with chronic liver disease. MRI has numerous advantages, including lack of ionizing radiation and the possibility of performing...Full Text Available
2009-07-01
The medical exposures to ionizing radiations, it is a world priority in radiation protection
International Nuclear Information System (INIS)
The document published under A/63:46 and titled report of the scientific committee of United Nations for the study of ionizing radiations effects, gives the situation of the fifty sixth session of the committee that stood at Vienna from the 10. to 18. july 2008. In the chapter 3 of this report the writers summarize the strategic planning and the working program of the scientific committee for the period 2009-2013. They note that the committee worry about the inadequate means, particularly in personnel. The priorities for the given period will be the medical exposure of patients, the radiation levels and the effects of energy production, the exposure to natural radiation sources and the improvement of the understanding of the effects of the low doses radiation exposure. (N.C.)
Study of total ionizing dose radiation effects on nitride/oxide stack gate MOS capacitor
International Nuclear Information System (INIS)
The aim of this paper is to investigate the total ionizing dose (TID) radiation effects on MOS capacitor with nitride/oxide stack gate. The stack gate MOS capacitors are fabricated with 20 nm oxide, 40 nm nitride or 110 nm nitride respectively. Through the analysis of CV curve of the irradiation capacitors, it is found that the degradation of the CV curve is due to a significant increase of interface traps and somewhat smaller oxide charge. It is also shown that the thicker of the nitride, more interface traps and oxide charge will be occurred. (authors)
2008-07-01
Radiation-induced chemical modification of wood
International Nuclear Information System (INIS)
The results of theoretical and experimental investigations, describing the effect of ionizing radiation on wood and its main components and methods for production of wood-plastic composites by means of radiation-induced chemical modification are generalized. Domestic and foreign experience in their production is systematized; physico-mechanical characteristics of new material, simulation and calculation of irradiating devices, as well as calculation and experimental study of #gamma#-radiation attenuation both by wood material and by wood of different species are given. Gamma sources ("6"0Co isotope, a hot loop of a nuclear reactor) as well as electron accelerators are considered as ionizing radiation sources.
1985-01-01
New techniques for electron-ion collision studies
International Nuclear Information System (INIS)
We have constructed an apparatus to study electron impact ionization of ions which should provide additional insight into the mechanisms involved. Using multiparameter coincidence techniques, we will detect both outgoing electrons from ionization process and will be able to analyze the momenta of both particles simultaneously. Coupled with a high resolution electron gun, this information should have broad application to the difficult problem of three bodies interacting via the long range Coulomb force. If sufficient accuracy can be achieved, information regarding the relative phase of the outgoing electron wavefunctions can be obtained.
Magnetic braking in weakly ionized media
International Nuclear Information System (INIS)
The combined magnetic braking-ambipolar diffusion problem in weakly ionized, rigidly rotating disks is studied. An analytical solution is presented for a disk whose angular velocity and magnetic yield vectors are aligned with the symmetry axis, illustrating the effects of the relative azimuthal drift of neutrals and ions. The effects of radial drift are added, commenting on the ratio of the characteristic ambipolar diffusion and magnetic braking time scales in high-mass and low-mass disks. A numerical calculation is used to show the combined action of these two processes. 31 references.
Ionizing radiation hardening procedure of CCD's
International Nuclear Information System (INIS)
The procedure of charge-coupled devices (CCD) are investigated by using MOS capacitors for enhancing their ionizing radiation tolerance. Authors have found that the gate oxidation temperature, thickness of SiO_2 gate insulator and high temperature processes after gate oxidation are crucial for determining the radiation tolerance of the devices, and proposed to decrease the thickness of gate insulator, perform gate oxidation at 1000 deg C by means of dry oxidation and minimize the number of high temperature procedure steps after gate oxidation. All stated above is a necessary preparation for priducing radiation hardened charge-coupled devices.
Health effects[1997 Scientific Report of the Belgian Nuclear Research Centre
Energy Technology Data Exchange (ETDEWEB)
The objectives of the research in the field of epidemiology , performed at the Belgian Nuclear Research Centre SCK-CEN are (1) to study cancer mortality and morbidity in nuclear workers in Belgium; (2) to document the feasibility of retrospective cohort studies in Belgium; (3) to participate in the IARC study. For radiobiology, the main objectives are: (1) to elucidate the mechanisms of the effects of ionizing radiation on the mammalian embryo during the early phase of its development, (2) to assess the genetic risks of maternal exposure to ionizing radiation, (3) to elucidate the mechanisms by which damage to the brain and mental retardation are caused in man after prenatal irradiation. The main achievements in these domains for 1997 are presented.
1998-07-01
International Nuclear Information System (INIS)
Hitherto in this laboratory, ionization coefficients alpha and attachment coefficients #eta# have been determined from Townsend's discharge experiments by a curve-fitting method. However, the method proved to be laborious, Formulae have been derived in this paper to give value of alpha and #eta# as a function of Isubo, Isub1 and Isub2 where Isubo is the photoelectric current at a gap setting d and Isub2 the current at another gap setting 2 d. The values of alpha and #eta# obtained give currents in agreement to within 3% in the best cases with the observed currents.
Energy Technology Data Exchange (ETDEWEB)
Neutral atom beams with energies above 200 keV may be required for various purposes in magnetic fusion devices following TFTR, JET and MFTF-B. These beams can be produced much more efficiently by electron detachment from negative ion beams than by electron capture by positive ions. We have investigated the efficiency with which such neutral atoms can be produced by electron detachment in partially ionized hydrogen plasma neutralizers.
1980-09-01
Effects of relativity and wave functions on atomic L- and M-shell ionization by protons
Energy Technology Data Exchange (ETDEWEB)
Atomic L- and M-shell ionization cross sections by protons have been calculated in the plane-wave Born approximation for /sub 79/Au and /sub 92/U with incident energy from 0.1 to 3 MeV with use of relativistic and nonrelativistic Hartree-Slater wave functions. These results are compared with those from the screened hydrogenic model to study the effects of relativity and wave functions. The relativistic and wave-function effects are found to operate in opposite directions. For M/sub 1,2,3/-subshell cross sections, severe cancellations occur between these two factors.
1984-10-01
Discharging-ionization of tellurium in nitric acid electrolytes in the presence of tartrate ions
The authors investigated the influence of tartaric acid, which possesses complex-forming properties. In order to establish the optimum system of possible refinement of tellurium, the authors study the kinetics of both the cathodic and the anodic processes. The investigation of processes of discharging-ionization of tellurium from nitric acid electrolytes in the presence of tartrate ions showed the possibility of preparing a nitric-tartaric acid electrolyte which can be used for commercial purposes and from which a high-purity raffinate was obtained from technical tellurium.
1986-03-20
Energy Technology Data Exchange (ETDEWEB)
This work presents a study of the {sup 1}P{sup 0} excited states of He that can be reached by absorption of a single photon carrying an energy close to the double ionization threshold (DIT) (79 eV). Above the DIT, these states are the double continuum states; below, they are the double excited states. These two types of states are tightly coupled to the single continuum states with or without excitation of the residual ion He{sup +}, owing to their degeneracy in energy. In a one-photon process, these states can only be formed owing to the electronic correlations in the system which must be well described to obtain quantitative good results. Our study is a part of the work which aims at a united description of all these doubly excited, ionized-excited, and double continuum states. We use the Hyperspherical R-Matrix with Semiclassical Outgoing Waves (HRM-SOW) method, initially dedicated to double photoionization studies. We extend it to extract ...
2007-04-15
High-pressure gas quenching in cold chambers for increased cooling capacity
Energy Technology Data Exchange (ETDEWEB)
Gas quenching for the hardening of steel parts is a lower-pollution alternative to quenching in quenchants such as oil or salt. As the surfaces of the cooled parts remain clean after gas quenching, there is no need to wash them after heat treatment, which reduces the consumption of oils and detergents. The fire risk and ventilation requirements of oil quenching are eliminated. In addition, some trials have shown that gas quenching has a positive effect on distortion, representing a saving in finishing work and thus a reduction in costs. Today, gas quenching is used almost solely in vacuum furnaces. Quenching is normally performed in the same chamber as heating, which means that besides quenching the batch, the quenching system must also remove heat from the heating elements and insulation of the furnace. Previous trials performed by IVF have shown that gas quenching with helium of ball bearing and carburizing steels (and other steels) in sizes up to 25 mm at ...
1996-12-31
Turbulent mixing in the foot piece of a HPLWR fuel assembly
International Nuclear Information System (INIS)
A homogeneous turbulent mixing of coolant flows with different temperatures at the fuel assembly inlets is an important requirement to minimize hot spots in a fuel assembly of a High Performance Light Water Reactor (HPLWR). Therefore, the mixing chamber between lower core plate, flow adjuster and the mixing chamber within the cluster foot piece diffuser have been investigated using the Computational Fluid Dynamics (CFD)-code Fluent 6.1 and its implemented k-#epsilon# model. The previously presented 3D-CAD-geometry has been simplified using Gambit 2.1.2 and consists of various inlet and outlet tubes or channels in the foot piece bottom plate, the lower core plate and the flow adjuster establishing the boundaries of two consecutive mixing chambers. The temperature distribution at the inlet of the sub-channels of the cluster fuel assemblies is presented. It reveals temperature variations at the coolant inlet of the nine fuel ...
2005-10-09
The performance of jet fuel with an oxidant mixture containing 70 percent liquid fluorine and 30 percent liquid oxygen by weight was investigated in a 500-pound-thrust engine operating at a chamber pressure of 300 pounds per square inch absolute. A one-oxidant-on-one-fuel skewed-hole impinging-jet injector was evaluated in a chamber of characteristic length equal to 50 inches. A maximum experimental specific impulse of 268 pound-seconds per pound was obtained at 25 percent fuel, which corresponds to 96 percent of the maximum theoretical specific impulse based on frozen composition expansion. The maximum characteristic velocity obtained was 6050 feet per second at 23 percent fuel, or 94 percent of the theoretical maximum. The average thrust coefficient was 1.38 for the 500-pound thrust combustion-chamber nozzle used, which was 99 percent of the theoretical (frozen) maximum. Mixtures of fluorine and oxygen were found to be ...
1954-01-01
Parametric study of radiative cooling of solid antihydrogen. Master's thesis
Energy Technology Data Exchange (ETDEWEB)
A computer model of cryogenic system for storing solid antimatter is used to explore the radiative cooling-power requirements for long-term antimatter storage. If vacuum-chamber pressures as low as 10 to -18th power torr can be reached, and the rest of the large set of assumptions is valid, milligram quantities of solid antimatter could be stored indefinitely at 1.5 K using cooling powers of less than a microwatt. Many of the assumptions made are problematic and need verification, as they could potentially change the results greatly. The system modeled is a sphere of solid anti-parahydrogen at 1.5 K or below levitated in a spherical cryogenic vacuum chamber. The free matter gas in the chamber is assumed to be molecular hydrogen, and sublimation of both matter and antimatter is assumed to be negligible. The antihydrogen is assumed to be in thermal equilibrium, although annihilation-energy deposition is localized and ...
1989-03-01
New facility design and work method for the quantitative fit testing laboratory. Master's thesis
Energy Technology Data Exchange (ETDEWEB)
The United States Air Force School of Aerospace Medicine (USAFSAM) tests the quantitative fit of masks which are worn by military personnel during nuclear, biological, and chemical warfare. Subjects are placed in a Dynatech-Frontier Fit Testing Chamber, salt air is fed into the chamber, and samples of air are drawn from the mask and the chamber. The ratio of salt air outside the mask to salt air inside the mask is called the quantitative fit factor. A motion-time study was conducted to evaluate the efficiency of the layout and work method presently used in the laboratory. A link analysis was done to determine equipment priorities, and the link data and design guidelines were used to develop three proposed laboratory designs. The proposals were evaluated by projecting the time and motion efficiency, and the energy expended working in each design. Also evaluated were the lengths of the equipment links for each proposal, and ...
1989-05-01
Methodological study of hemodynamic analysis of lung mass by contrast enhanced dynamic CT
Energy Technology Data Exchange (ETDEWEB)
We investigated a method of analyzing the hemodynamics of the lung mass by contrast enhanced dynamic computed tomography (dynamic CT) to determine the difference in vascular supply between the pulmonary artery and bronchial artery using an experimental model. Our experimental model consisted of two injectors connected to two tubes, representing the pulmonary artery and bronchial artery, which were further connected to a chamber representing the lung mass. Following infusion of contrast medium into each tube with some delay time, dynamic CT scans were performed to obtain time density curves of the two tubes and the chamber. Using the time-density curve of contrast passage, flow rates from the two tubes into the chamber were calculated by the curve fitting method. Calculated values correlated well with the adopted flow rates of fluid from the injectors (r=0.893) in the experiment. The results indicate our method of ...
1996-06-01
Methodological study of hemodynamic analysis of lung mass by contrast enhanced dynamic CT
International Nuclear Information System (INIS)
We investigated a method of analyzing the hemodynamics of the lung mass by contrast enhanced dynamic computed tomography (dynamic CT) to determine the difference in vascular supply between the pulmonary artery and bronchial artery using an experimental model. Our experimental model consisted of two injectors connected to two tubes, representing the pulmonary artery and bronchial artery, which were further connected to a chamber representing the lung mass. Following infusion of contrast medium into each tube with some delay time, dynamic CT scans were performed to obtain time density curves of the two tubes and the chamber. Using the time-density curve of contrast passage, flow rates from the two tubes into the chamber were calculated by the curve fitting method. Calculated values correlated well with the adopted flow rates of fluid from the injectors (r=0.893) in the experiment. The results indicate our method of ...
Energy Technology Data Exchange (ETDEWEB)
Causes of variation of hydrocarbon (HC) concentration in cylinder to cylinder at idling condition in a direct injection diesel engine were studied. The ratio of l/d=6 gives larger HC variation in cylinder to cylinder than the l/d=2, where l means the nozzle hole length and d means the nozzle hole diameter. This is because the condition of l/d=6 can result in the large spray penetration and increase the fuel on the combustion chamber. The spray structure changes between nozzles and also changes between nozzle holes. This is not caused by the shape of nozzle hole but is affected by the pressure change near the inlet of nozzle hole when the needle valve is lifted. The change of spray structure can change the injection volume between nozzle holes. The injection volume is less for a nozzle hole where the curved angle becomes sharp to the nozzle central angle, and is more at the opposite side. When the injection volume of the nozzle hole near the ...
1992-07-01
Granular flow considerations in the design of a cascade solid breeder reaction chamber
International Nuclear Information System (INIS)
Both horizontally and vertically oriented rotating chambers with granular material held on the inner surface by centrifugal action are examined. Modifications to the condition for controlled quasi-static flow on an incline plane, phi/sub w/ < #alpha# < phi/sub r/, where phi/sub w/ is the wall friction angle, #alpha# is the angle of inclination of the plane, and phi/sub r/ is the drained angle of repose of the material are examined for the case of horizontal and vertical surfaces of revolution. Allowed included half angles for horizontally oriented chambers are likely to be in the range of 30"0 +- 10"0 for ceramic particles and metal surfaces. For vertical orientations the maximum half-angle of the top cone is slightly less than the wall friction angle phi/sub w/ while the lower portion can have a half angle as large as (90"0 - phi/sub w). Percolation of fines through shearing granular solids is briefly discussed and recommended ...
1970-05-01
Electrochemical power generation apparatus and methods
Energy Technology Data Exchange (ETDEWEB)
Apparatus and methods are described for generating heat and electricity from the consumption of a variety of aluminum products. The method consists of (A) a reaction chamber containing an aqueous electrolyte solution and adapted for introduction therein of aluminum pieces of various shapes and sizes up to a certain maximum predetermined size and for effecting a chemical reaction between said aqueous electrolyte and said aluminum pieces yielding aluminum hydroxide and an intermediate reactant; (B) means for feeding said aluminum pieces into said reaction chamber in small quantities upon demand; (C) means for removing the heat generated in said chamber as a result of said reaction; (D) means for removing said aluminum hydroxide reaction product; and (E) means for oxidizing said intermediate reactant in an electrochemical cell, thereby generating electrical energy. The intermediate reactant is preferably hydrogen or zinc. The ...
1981-03-03
Electrochemical power generation
Energy Technology Data Exchange (ETDEWEB)
Apparatus and methods for generating heat and electricity from the consumption of a variety of aluminum products comprise: (A) a reaction chamber containing an aqueous electrolyte solution and adapted for introduction therein of aluminum pieces of various shapes and sizes up to a certain maximum predetermined size and for effecting a chemical reaction between said aqueous electrolyte and said aluminum pieces yielding aluminum hydroxide and an intermediate reactant; (B) means for feeding said aluminum pieces into said reaction chamber in small quantities upon demand; (C) means for removing the heat generated in said chamber as a result of said reaction; (D) means for removing said aluminum hydroxide reaction product; and (E) means for oxidizing said intermediate reactant in an electrochemical cell, thereby generating electrical energy. The intermediate reactant is preferably hydrogen or zinc. The latter may be used in a ...
1983-01-18
Anode Front-End Electronics for the Cathode Strip Chambers of the CMS Endcap Muon Detector
The front-end electronics system for the anode signals of the CMS Endcap Muon cathode strip chambers has about 183000 channels. The purposes of the anode front-end electronics are to acquire precise muon timing information for bunch crossing number identification at the Level-1 muon trigger system and to provide a coarse radial position of the muon track. Each anode channel consists of an input protection network, amplifier, shaper, constant-fraction discriminator, and a programmable delay. The essential parts of the electronics include a 16-channel amplifier-shaper-discriminator ASIC CMP16 and a 16-channel ASIC D16G providing programmable time delay. The ASIC CMP16 was optimized for the large cathode chamber size (up to 3 x 2.5 m2) and for the large input capacitance (up to 200 pf). The ASIC combines low power consumption (30 mW/channel) with good time resolution (2 - 3 ns). The del ay ASIC D16G makes possible the alignment of signals with an ...
2005-01-01
Energy Technology Data Exchange (ETDEWEB)
The results of an experimental investigation of the performance of a small bore engine with a swirl chamber when operating as a dual fuel engine with commercial methane as the gaseous fuel were presented in this paper. The experiment involved using a 3-dimensional computational fluid dynamics model to predict the performance of the engine. A detailed chemical kinetics for the gaseous fuel component, consisting primarily of methane and a reduced detailed chemical kinetics for the diesel fuel while considering the turbulent combustion processes an associated performance of a dual fuel engine with a swirl chamber were incorporated in the simulation. The study experimentally and numerically investigated the effects of changes in the quantities of the liquid fuel pilot and gaseous fuels on the combustion processes, engine performance, cyclic variations, and emissions. The paper discussed the experimental approach and results. It also discussed the ...
2007-07-01
A tool for the LHCb MWPC production monitoring the LNF on-line database
The LHCb Muon detector system is made of several (1368) Multi Wire Proportional Chambers (MWPCs). Those chambers differ in size, readout and constructing materials and are built in various countries: their assembly takes place in different sites and foresee many steps. To ensure the production quality and keep track of panels/chambers production an on-line database has been set up. This web based tool allows an easy sharing of the information: the database update is made possible trough a web interface. The update is easy and reliable. The interface helps the information sharing in different sites and helps optimizing the production rate by allowing feedback on production needs and quality between sites contributing to the production chain. The planning is made using the information on the material availability. Quality tests and crosschecks are made easier, as well as the overall production monitoring. The tool has been ...
2006-01-01
International Nuclear Information System (INIS)
The use of primary electron counting techniques as an alternative to the more usual parallel plate avalanche chamber that has been employed in soft x-ray scattering experiments is being investigated at the National Synchrotron Light Source. The theoretical aspects of primary electron counting and motivation behind building a primary electron counting detector are described, as well as characteristics and future improvements of the device constructed at the NSLS. The detector consists of a low electric field drift region and a low pressure multistep avalanche region which can be operated with two or three stages of electron multiplication. The device has worked well in extensive tests as a simple parallel plate avalanche chamber, providing energy resolutions of 58% and 43% at 277 and 500 eV, respectively. Operated as a primary electron counter, preliminary results show an energy resolution of 38% at 500 eV.
We formulate a complete theory of Edge Radiation based on a novel method relying on Fourier Optics techniques. Similar types of radiation like Transition Undulator Radiation are addressed in the framework of the same formalism. Special attention is payed in discussing the validity of approximations upon which the theory is built. Our study makes consistent use of both similarity techniques and comparisons with numerical results from simulation. We discuss both near and far zone. Physical understanding of many asymptotes is discussed. Based on the solution of the field equation with a tensor Green's function technique, we also discuss an analytical model to describe the presence of a vacuum chamber. In particular, explicit calculations for a circular vacuum chamber are reported. Finally, we consider the use of Edge Radiation as a tool for electron beam diagnostics. We discuss Coherent Edge Radiation, Extraction of Edge Radiation by a mirror, and ...
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
The isothermal flow field for the axial cyclone has been experimentally determined. The velocity fields are used for determination particle paths (particle removal and suspended state), and inter alia of heat and mass transfer processes in the axial cyclone combustion chamber. The results are extremely significant as input value approximations for mathematical modelling, since experimentally obtained results are indispensable for complex flows and geometries. (orig.) [Deutsch] Es ist fuer den Axialzyklon experimentell das isotherme Stroemungsfeld ermittelt. Die Geschwindigkeitsfelder dienen zur Ermittlung der Partikelbahnen (Partikelabscheidung, Schwebebedingung), der Waerme- und Stoffuebertragungsprozesse u.a. in der Axialzyklonbrennkammer. Die Ergebnisse sind als Startwertnaeherung bei einer mathematischen Modellierung sehr wichtig, da bei komplexen Stroemungen und Geometrien versuchstechnische Ergebnisse unumgaenglich sind. (orig.)
1994-12-31
Modeling of a self-excited pulse combustor and stability analysis
British Library Electronic Table of Contents (United Kingdom)
The major bottleneck for popularization and utilization of the conventional mechanical valve pulse combustors is the self-priming mode of gas supply. An aerodynamic valve (as against mechanical valve) self-excited pulse combustor of the Helmholtz-type with continuous supply of gas and air was designed and a mathematical model was established in this paper. The theoretical model employed well-stirred reactor model and a single step Arrhenius chemistry, and took those factors which might affect the combustion stability into account. The factors include the variation of the mass rate of the reactants affected by the pressure in the combustion chamber, the convective and radiation heat loss in the combustion chamber, and the heat transfer and wall friction in the tailpipe. The effect of wall t...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
A method for determining the mobility of hydrogen as a function of temperature in superconducting niobium cavities comprising: 1) heating a cavity under test to remove free hydrogen; 2) introducing hydrogen-3 gas into the cavity; 3) cooling the cavity to allow absorption of hydrogen-3; and 4) measuring the amount of hydrogen-3 by: a) cooling the cavity to about 4.degree. K while flowing a known and regulated amount of inert carrier gas such as argon or helium into the cavity; b) allowing the cavity to warm at a stable rate from 4.degree. K to room temperature as it leaves the chamber; and c) directing the exit gas to an ion chamber radiation detector.
2008-03-11
Membrane barriers for radon gas flow restrictions
International Nuclear Information System (INIS)
Research was performed to assess the feasibility of barrier membrane substances, for use within mining or associated high risk environments, in restricting the diffusion transport of radon gas quantities. Specific tests were conducted to determine permeability parameters of a variety of membrane materials with reference to radon flow capabilities. Tests were conducted both within laboratory and in-situ emanation environments where concentrations and diffusion flows of radon gas were known to exist. Equilibrium radon gas concentrations were monitored in initially radon-free chambers adjacent to gas sources, but separated by specified membrane substances. Membrane barrier effectiveness was demonstrated to result in reduced emanation concentrations of radon gas within the sampling chamber atmosphere. Minimum gas concentrations were evidenced where the barrier membrane material was shown to exhibit lowest radon permeability characteristics.
Low emission fuel engine and method of operating same
Energy Technology Data Exchange (ETDEWEB)
This patent describes a low emission duel fuel engine system. It comprises: a dual fuel engine having a combustion chamber; a fuel oil supply connected to the engine; a fuel gas supply connected to the engine; and means connected between the fuel oil supply and the engine for injecting fuel oil into the engine. The means connected between the engine and fuel oil supply limiting the injection of fuel oil to the combustion chamber to pilot ignition quantities only, wherein the limiting means includes means for limiting the injection of fuel oil such that the exhaust emission of NO{sub x} is at an emission rate of less than 1 GM/PH-HR, whereby the exhaust emission performance of the dual fuel engine is enhanced.
1990-09-11
Energy Technology Data Exchange (ETDEWEB)
The light gain due to S/sub 2/ molecules in a supersonically cooled gas mixture is calculated. The S/sub 2/ molecules formed due to the recombination of the sulfur atoms, and the combustion gas mixture was preheated in a precombustion chamber. Optimal gas flow and nozzle parameters are found which correspond to the highest possible light gain using Cs/sub 2/-Ar and S/sub 2/-Ar gas mixtures. The steady state gas flow in the nozzle was calculated, taking into account the chemical reactions in the one-dimensional approximation. It is shown that the maximum gain values vary in the 0.0001-0.002 range for gas pressures in the precombustion chamber in the range 10-100 atm. The optimal initial relative concentration of Cs/sub 2/ molecules and S/sub 2/ molecules are given. 32 references.
1985-08-01
Energy Technology Data Exchange (ETDEWEB)
A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a {sup 241}Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).
1991-01-01
International Nuclear Information System (INIS)
A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a "2"4"1Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).
Hydrogen production in a 5 kW Diesel Oxidative Steam Reformer
Energy Technology Data Exchange (ETDEWEB)
This paper presents a reformer prototype for the production of the necessary H{sub 2} to supply a 5 kW PEMFC and its first results. The fuel processor consists of an OSR and a WGS and a PROX reactors. The design of the system was carried out with a one-dimensional model. The mixture chamber was specially studied with a CFD code (Fluent), taking into account the effect of fuel evaporation and the cool flame process. The aim of the designed facility is to be able of characterising each component and controlling each working parameter. Eventually, using diesel as fuel, results from the mixture chamber, OSR, WGS and PROX reactors are presented. It also includes conclusions and future works. (authors)
2006-07-01
Fuel injection control for diesel engine
Energy Technology Data Exchange (ETDEWEB)
A method is described for controlling fuel injection in a diesel engine having a fuel injection nozzle, comprising the steps of: detecting an idling state of the diesel engine and pressure in a combustion chamber; obtaining a pressure increment rate from the pressure detected by the detecting step; selecting a valve opening pressure of the fuel injection nozzle at a relatively low level when the idling state is detected by the detecting step, thereby setting a two peaks characteristics of a fuel injection rate; and controlling the fuel injection nozzle in response to the pressure increment rate so that the pressure increment rate in the combustion chamber is maintained within a predetermined value by changing a fuel injection quantity of a pilot injection from the fuel injection nozzle.
1987-11-10
British Library Electronic Table of Contents (United Kingdom)
In order to replace copper fungicides in organic potato production, 53 copper-free preparations (CFPs) based on natural compounds, including plant extracts and microorganisms, and five copper preparations were evaluated for their potential to control Phytophthora infestans, the pathogen that causes late blight of potatoes. In in vitro assays, 30% of the CFPs inhibited indirect germination of sporangia, 26% mycelial growth and in growth chamber experiments, 21% efficiently reduced foliar blight of tomato plants. In micro-plot field trials with applications twice a week, the copper preparations were the most effective and reduced foliar blight by 99%. Of the CFPs tested, Oekofluid P, Mycosin and other sulphuric clays, and C-2000 reduced late blight the most, from 63% to 37%. In small-plot tr...
2007-01-01
Apparatus for measuring the decontamination factor of a multiple filter air-cleaning system
Energy Technology Data Exchange (ETDEWEB)
An apparatus for measuring the overall decontamination factors of first and second filters located in a plenum. The first filter separates the plenum's upstream and intermediate chambers. The second filter separates the plenum's intermediate and downstream chambers. The apparatus comprises an aerosol generator that generates a challenge aerosol. An upstream collector collects unfiltered aerosol which is piped to first and second dilution stages and then to a laser aerosol spectrometer. An intermediate collector collects challenge aerosol that penetrates the first filter. The filtered aerosol is piped to the first dilution stage, diluted, and then piped to the laser aerosol spectrometer which detects single particles. A downstream collector collects challenge aerosol that penetrates both filters. The twice-filtered aerosol is piped to the aerosol spectrometer. A pump and several valves control the movement of aerosol within the ...
1985-07-03
Aging measurements of a TMAE-based photon detector for the HERA-B RICH
We report on aging measurements of a photon detector candidate for the HERA-B RICH. The prototype, a proportional wire chamber operated with TMAE, was mounted on an argon filled test-beam RICH and was aged by UV light at rates we expect in HERA-B. We monitored gain and current continuously, and checked the chamber with Cherenkov photons at regular intervals. The number of detected photons/track (projected to 2.75 m C sub 4 F sub 1 sub 0 in HERA-B) dropped from 26 to 11 after two days of aging - well below the 20 required for pi/K separation. Based on these results, HERA-B decided to use multi-anode PMTs as photon detectors in the RICH.
1999-01-01
Activation analysis of target debris in the national ignition facility
International Nuclear Information System (INIS)
The modeling methods used to compute the neutron-induced activation of target and near-target materials in the NIF facility are presented. A detailed space and energy description of the neutron environment in the different materials is provided. A new capability has been developed to treat in a general way the activation of debris produced in an operational regime of yield and no-yield experiments. First calculations are addressed to analyze the activity of the debris into the target chamber. The contribution of the different components to activity, interior dose rates, and waste disposal rating (WDR) is determined. The importance of the activation coming from primary irradiation in the target, and from secondary irradiation in debris deposited onto the first wall is assessed. Finally, waste hazards of the activated debris when removed out of the chamber and stored are analyzed. (authors)
1999-09-12
Study on the energy distribution of ion beams extracted from the sputter-type negative-ion source
International Nuclear Information System (INIS)
The energy distribution of ion beams is important especially for low energy ion beam applications. The energy distributions of negative-ion beams produced through secondary ion emission by sputtering were measured and compared with theoretically estimated distributions by use of four different negative-ion production probability equations (modified surface ionization model, exponential velocity dependence model, and our modified exponential velocity dependence models (modified decaying factor model and combination model of velocity dependence and surface ionization)). In the measurements, the energy distributions of C"- and Ag"- beams had a peak at a few to several eV and the full width at half maximum were 15 eV and 11 eV, respectively. These results could be well explained by the estimated distributions by virtue of our combination model or the modified surface ionization model. copyright 1996 American Institute of ...
1995-10-23
Somatic and genetic effects of small doses of ionizing radiations in man
International Nuclear Information System (INIS)
Estimations on the somatic and genetic effects of small doses of ionizing radiations in Man have been proposed by the Advisory Committee on the Biological Effects of Ionizing Radiation, set up by the U.S. National Academy of Sciences. They have been published in an important report, issued in 1972, from which we briefly analyze here the Chapter dealing with the somatic effects. Small doses of raditions are expected to promote only carcinogenic effects. After a rapid survey of the human experience on which the estimations are based, as regards the latent period of cancers, the plateau region (period of high risk) and the absolute and relative risk expressed per rem, per 10"6 persons, per year, for leukaemia (having the highest risk) and for the ''other cancers''. These estimations were obtained by linear extrapolation to the 1 rem level from observations made after irradiation at relatively high dose levels and much higher dose-rates. This ...
1976-01-01
Salmonella radicidation of poultry carcasses
International Nuclear Information System (INIS)
This thesis reports investigations using gamma-radiation to decontaminate poultry carcasses. The application to foods of doses of ionizing radiation sufficient to reduce the number of viable specific non-sporeforming pathogenic microorganisms so that none is detectable in the treated food by any standard method is termed radicidation. The doses used in this study were at such a level that no undesirable or unfavourable side-effects occurred. The effects of these doses were studied on salmonellae and other microorganisms present in, or associated with poultry carcasses and in liquid and on solid culture media as well. Decimal reduction (D_1_0) values were estimated. These represent the dose (kGy) required to achieve a reduction in initial colony count from N_0 to 0.1 N_0. Together with the estimation of the numbers of Salmonella present per carcass the data were used to predict the effect of an ionizing radiation treatment of poultry. Data on ...
2005-09-22
Risks and safety aspects related to PET/MR examinations
International Nuclear Information System (INIS)
The introduction of positron emission tomography (PET)/magnetic resonance (MR) systems into medical practice in the foreseeable future may not only lead to a gain in clinical diagnosis compared to PET/computed tomography (CT) imaging due to the superior soft-tissue contrast of the MR technology but can also substantially reduce exposure of patients to ionizing radiation. On the other hand, there are also risks and health effects associated with the use of diagnostic MR devices that have to be considered carefully. This review article summarizes biophysical and biological aspects, which are of relevance for the assessment of health effects related to the exposure of patients to both ionizing radiation in PET and magnetic and electromagnetic fields in MR. On this basis, some considerations concerning the justification and optimization of PET/MR examinations are presented - as far as this is possible at this very early stage. Current safety ...
2009-03-01
Resonance ionization spectroscopy at {sup 240f,242f}Am fission isomers
Energy Technology Data Exchange (ETDEWEB)
Optical Isotope shift measurements have been performed for the {sup 240f,242f}Am fission isomers to test the stability of nuclear deformation as function of the neutron number. The method is based on resonance ionization spectroscopy (RIS) in a buffer gas cell with fission detection of the ionization process. The {sup 240f,242f}Am fission isomers have been produced by {sup 242}Pu(p, 3n), {sup 242}Pu(d, 2n) reactions, respectively. Relative isotope shift ratios X{sub exp}{sup 242f}(500 nm)=IS{sup 242f,241}/IS{sup 243,241}=41.4(8) and X{sub exp}{sup 240f}(500 nm)=IS{sup 240f,241}/IS{sup 243,241}=39.2(8) were measured. From these ratios a small difference {delta}{beta}{sub 2}{sup 242f,240f}=0.0076(14) of the deformation parameter {beta}{sub 2} can be deduced assuming that the isotope shift between the reference isotopes {sup 241,243}Am is caused by a pure volume change. (orig.)
1997-10-01
Oxygen O18 method and the search for the ionization mechanism in sputtering of oxygenated surfaces
International Nuclear Information System (INIS)
Recently developed oxygen O18 method [K. Franzreb, J. Lorincik, P. Williams, Surf. Sci. 573 (2004) 291; R.C. Sobers, K. Franzreb, P. Williams, Appl. Surf. Sci. 231-232 (2004) 729; P. Williams, R.C. Sobers Jr., K. Franzreb, J. Lorincik, Appl. Surf. Sci. 252 (2006) 6429] is able to quantitatively determine the flux ratio of oxygen to matrix species at dynamical SIMS sputtering. This flux ratio can be directly related to the surface oxygen concentration at dynamical sputtering - an important parameter controlling the ionization yield of emitted species. It is argued that the oxygen O18 method is a worthy step forward in gathering relevant experimental data that might eventually lead to the understanding of oxygen enhancement mechanism in SIMS. A current status of understanding of the ionization processes in SIMS is briefly discussed in terms of non-adiabatic strongly velocity dependent processes represented by the electron tunneling and ...
2008-12-15
Matrix-assisted laser desorption fourier transform mass spectrometry for biological compounds
The recent development of matrix-assisted UV laser desorption (LD) mass spectrometry has made possible the ionization and detection of extremely large molecules (with molecular weights exceeding 100,000 Daltons). This technique has generated enormous interest in the biological community for the direct examination of large peptides and oligonucleotides. Although this matrix-assisted ionization method has been developed and used almost exclusively with time-of-flight (TOF) mass spectrometers, research is currently in progress to demonstrate this technique with trapped ion mass spectrometers, such as Fourier transform ion cyclotron resonance mass spectrometry (FTMS). The potential capabilities of FTMS for wide mass range, high resolution measurement, and ion trapping experiments suggest that this instrumental technique should be useful for the detailed structural characterization of large ions generated by the matrix-assisted technique. We have ...
1990-01-01
Locally Optimally-emitting Clouds and the Narrow Emission Lines in Seyfert Galaxies
The narrow emission line spectra of active galactic nuclei are not accurately described by simple photoionization models of single clouds. Recent Hubble Space Telescope images of Seyfert 2 galaxies show that these objects are rich with ionization cones, knots, filaments, and strands of ionized gas. Here we extend to the narrow line region the ``locally optimally emitting cloud'' (LOC) model, in which the observed spectra are predominantly determined by powerful selection effects. We present a large grid of photoionization models covering a wide range of physical conditions and show the optimal conditions for producing many of the strongest emission lines. We show that the integrated narrow line spectrum can be predicted by an integration of an ensemble of clouds, and we present these results in the form of diagnostic line ratio diagrams making comparisons with observations. We also predict key diagnostic line ratios as a function of distance ...
1997-01-01
K beta X-ray transition energies of M-shell-ionized ions of Ti through Ni in a plasma
Energy Technology Data Exchange (ETDEWEB)
K beta X-ray lines from partially M-shell-ionized ions of titanium through nickel which are produced in vacuum-spark plasmas have been observed systematically for the first time, using a high-resolution curved-crystal spectrometer. Each K beta line is clearly separated into its corresponding charge state. As a result, it is possible to measure the K beta-type transition energies of the M-shell-ionized ions. The transition energies accurately determined are compared with those calculated for iron ions, and the agreement is excellent except for ions having some additional 3d outer-shell electrons or 3s inner-shell vacancies. The square root of the K beta transition frequency is expressed as a linear function of the nuclear charge for isoelectronic sequences. The effective nuclear charges have been also determined for each K beta transition. The 3p electrons do not affect the effective nuclear charges. 10 references.
1985-05-01
Ion-induced M X-ray emission from heavy lanthanides
Energy Technology Data Exchange (ETDEWEB)
Thick targets of several heavy lanthanide (Ho-Lu) compounds were bombarded by protons and /sup 3/He ions of 3 MeV/amu, and M/sub ..cap alpha../ and M/sub ..beta../ X-rays were measured with a crystal spectrometer. Ionization probabilities of the N-shell for zero impact parameter were obtained from the X-ray intensity ratio for proton and /sup 3/He ion impacts. A shell dependence of the ionization probability was found in a scaling plot. X-ray spectra of lanthanide compounds were compared and no chemical effect was observed. This result is considered to be due to the fact that the main component of M/sub ..cap alpha../ and M/sub ..beta../ lines is for radiative transition after the refilling of the 4f orbit (3d/sup -1/4f/sup n+1/ -> 4f/sup n/) where n denotes the number of 4f electrons of the target atom before ionization.
1987-12-01
How to overestimate risks of ionizing radiations
International Nuclear Information System (INIS)
Ignoring the numerous, known and mainly unknown, interactions between chemicals and ionizing radiations, causes strong controversy about the risks of ionizing radiations. Yet the best known interactions between chemicals and radiations is that between radon and tobacco smoke. Although it is and it will be always impossible to derive quite quantitative laws for this interaction, it has been possible to derive some semi-quantitative relationships based on reasonable assumptions and statistics on lung cancer deaths in developed countries. They show that ignoring the dangers of tobacco smoking as we did still long after we had recognised the dangers of radiations, could asses to radiations thirty or forty times more risks than reality. As present world is flown by tens of thousands chemicals, little or not present in a natural environment, and as it would be very surprising that some hundreds of these do not behave like those contained in tobacco ...
High Angular Resolution Imaging Spectroscopy of the Galactic Ultra-Compact HII Region K3-50A
Gemini North adaptive optics imaging spectroscopy is presented for the Galactic ultra-compact HII (UCHII) region K3-50A. Data were obtained in the K-band using the Near-infrared Integral Field Spectrograph (NIFS) behind the facility adaptive optics module ALTAIR in natural guide star mode. The NIFS data cube reveals a complex spatial morphology across the 0.1 pc scale of the 3'' UCHII region. Comparison of the nebular emission to Cloudy ionization models shows that the central source must have an effective temperature between about 37000 K and 45000 K with preferred values near 40000 K. Evidence is presented for sharp density variations in the nebula which are interpreted as a clearing of material nearest the central source. High excitation lines of FeIII and SeIV show that the ionization of the nebula clearly changes with distance from the central source. A double lobed kinematic signature (+/- 25 kms) is evident in the Br gamma line map which ...
2009-01-01
Enhanced MALDI-TOF MS Analysis of Phosphopeptides Using an Optimized DHAP/DAHC Matrix
Selecting an appropriate matrix solution is one of the most effective means of increasing the ionization efficiency of phosphopeptides in matrix-assisted laser-desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). In this study, we systematically assessed matrix combinations of 2, 6-dihydroxyacetophenone (DHAP) and diammonium hydrogen citrate (DAHC), and demonstrated that the low ratio DHAP/DAHC matrix was more effective in enhancing the ionization of phosphopeptides. Low femtomole level of phosphopeptides from the tryptic digests of ?-casein and ?-casein was readily detected by MALDI-TOF-MS in both positive and negative ion mode without desalination or phosphopeptide enrichment. Compared with the DHB/PA matrix, the optimized DHAP/DAHC matrix yielded superior sample homogeneity and higher phosphopeptide measurement sensitivity, particularly when multiple phosphorylated peptides were assessed. Finally, the ...
2010-01-01
DEFF Research Database (Denmark)
The aim of the present study was to test a mathematical model of the biochemical processes in the parathyroid glands responsible for the secretion of parathyroid hormone resulting from extracellular calcium reduction. A double exponential curve described the parathyroid hormone secretion induced by rapid lowering of blood-ionized calcium in humans with normal as well as abnormal parathyroid tissue. Our data show that it was possible to establish a simple mathematical model of the parathyroid hormone response to blood-ionized calcium lowering, sufficient to fit experimental data obtained from patients with abnormal and normal parathyroid tissue. The fitted parameters showed no significant differences between patients with insulin-dependent diabetes mellitus and controls. In primary hyperparathyroidism, the parathyroid hormone production and steady-state transport across the cell membrane were increased, probably due to the larger amount of ...
1997-01-01
Disposal of De-ionizer Vessels Highly Contaminated with 14Carbon at SRS
International Nuclear Information System (INIS)
At the Savannah River Site (SRS), nuclear production reactors used de-ionizers to control the chemistry of the reactor moderator during their operation to produce nuclear materials primarily for the weapons program. These de-ionizers were removed from the reactors and stored as a legacy waste with no path to disposal due to the relatively high 14C contamination (i.e., on the order of 20 curies per de-ionizer for 48-50 de-ionizers) and the low disposal limit of 4.2 Ci previously established for the Intermediate Level Vault (ILV). The ILV is considered most appropriate facility within which to dispose these items due to the method of solidifying waste items with cementitious material inside concrete vaults. In previous analyses the 14C ILV disposal limit was established at 4.2 Ci resulting from the use of a very conservative method to analyze the dose received from atmospheric releases of gaseous 14C. ...
2008-01-01
Use of radiosensitivity to identify irradiated fresh poultry products
International Nuclear Information System (INIS)
Microbiological comparison between irradiated and non-irradiated foodstuff has been studied for a long time as a way to detect whether a foodstuff has been irradiated or not. Generally, the proposed methods are based on the fact that ionization select species of bacteria which are recognized to be radioresistant. So reduction or elimination of known radiation sensitive microbes from the normal endogenous microflora could give an indication that the foodstuff has been irradiated, predominance of known radioresistant bacteria should be another indication. In the present work, we try to develop a test based on the radiosensitivity of the bacteria independently of their place. These first experiments show that the determination of radiosensitivity of strains isolated from a product or even of global radioresistance of mesophilic microflora could indicate if this product has been previously submitted to ionizing radiations. (4 tabs).
1990-02-14
The effect of neutrals on the performance of plasma opening switches
Energy Technology Data Exchange (ETDEWEB)
The authors address the question of the limitations on voltage and current transfer to loads in magnetic storage systems utilizing microsecond conduction time plasma opening switches. They propose that the limitation of performance results from neutral atoms that are not entrained into the ionized material that is driven by the magnetic field of the rising generator current. Evidence in support of this proposition is gathered from experiments performed on the Ace-4 and Hawk generators. They set forth a theory to describe the effect of neutrals on the electrical performance of plasma opening switches. The neutral gas is assumed to be present in the region between the moving plasma mass and the generator, primarily in the region in which the plasma is injected initially. The essential elements of the theory are a weak photoionization source to seed the gas with a low concentration of electrons, and joule heating accompanied by further ionization ...
1996-12-31
Retention of ring structure in cyclopentane and alkylcyclopentane molecular cations
Energy Technology Data Exchange (ETDEWEB)
All measurements were made with the NBS high-pressure photoionization mass spectrometer. The fractional of C/sub 5/H/sub 10//sup +/ions in a cyclopentane-cyclohexane mixture were determined as a function of pressure in order to define the fraction of the ions which did charge exchange with cyclohexane; i.e. the fraction which remained cyclic after ionization. The data for mixtures of various compositions (2.5 to 10% cyclohexane) are summarized for measurements performed at 10.62 eV: (a) 292K, > 96% cyclic; 347 K, greater than or equal to 94% cyclic; 386 K, 84 +- 4% cyclic; and 412 K, 78 +- 6% cyclic; entropy, enthalpy, and activation energy were determined; 10.49 eV was obtained as the ionization potential of cyclopentane. 1 figure.
1980-01-01
Energy Technology Data Exchange (ETDEWEB)
Long before possible organic effects, exposure to ionizing radiations can provoke anxiety. In front of invisibility, the imagination quickly ignites. The terrorists have perfectly understood it. They are ready to use ionizing radiations as a weapon to remind traumatic images deeply rooted in people's memory. These images induce anxiety with all the clinical expressions connected to it. These symptoms require to be treated because of a possible anarchic development. For that purpose, plans have been elaborated to coordinate the different professional's actions. The coherence of medical management and communication aims to allow the most implicated people to find the way to face the events. When it is not possible, medico-psychological cells permit a specialized care. (author)
2006-08-15
International Nuclear Information System (INIS)
Recent research findings of epidemiologist Alice Stewart suggest that nuclear workers may be at risk of contracting cancer even though their measured occupational doses fall within current safety standards. It is argued that these standards are inappropriate as they are based on extrapolations of studies on survivors of the Hiroshima and Nagasaki explosions. These individuals received single doses of radiation, whereas today's nuclear industry personnel are exposed to low-level ionizing radiation over the length of their working lives. Stewart's team linked low dose occupational exposure to ionizing radiation with an increased risk of cancer in respiratory, digestive and blood-forming tissues. The nuclear industry and United States government agencies hotly contest these assertion with their potentially damaging political and economic consequences. (UK).
1993-05-01
Energy Technology Data Exchange (ETDEWEB)
Recent research findings of epidemiologist Alice Stewart suggest that nuclear workers may be at risk of contracting cancer even though their measured occupational doses fall within current safety standards. It is argued that these standards are inappropriate as they are based on extrapolations of studies on survivors of the Hiroshima and Nagasaki explosions. These individuals received single doses of radiation, whereas today's nuclear industry personnel are exposed to low-level ionizing radiation over the length of their working lives. Stewart's team linked low dose occupational exposure to ionizing radiation with an increased risk of cancer in respiratory, digestive and blood-forming tissues. The nuclear industry and United States government agencies hotly contest these assertion with their potentially damaging political and economic consequences. (UK).
1993-05-15
International Nuclear Information System (INIS)
The book presents a very good account of all aspects of protection from ionizing radiation. The quantities and units are given and defined used in nuclear physics and dosimetry. The effects of ionizing radiation on cells and on man are described. The principles are presented of radiation protection including limits and valid regulations and decrees. Also discussed is internal irradiation and its modelling. A great part of the book is devoted to aspects of monitoring persons, the living and working environment and to the determination of internal contamination. The system of radiation protection in Czechoslovakia is described and some practical questions are discussed of protection during radiodiagnosis and radiotherapy, in the nuclear fuel cycle, in the operation of nuclear power installations and in crack detection. In conclusion a survey is given of the population exposure from various natural and artificial sources. (M.D.). 57 figs., 34 ...
1988-01-01
Energy Technology Data Exchange (ETDEWEB)
An investigation was made of the accumulation of laser damage to transparent polymers irradiated with nanosecond pulses from neodymium and ruby lasers. The damage was investigated by the method of scattering and luminescence in the visible and near ultraviolet parts of the spectrum. It was established that there were two stages in laser damage by repeated irradiation with pulses of intensity below the single-shot damage threshold. An absorbing defect evolved during the first stage in such a way as to create a thermal instability in the surrounding matrix. During the second stage this thermal instability caused spatial growth of laser damage because of propagation of an ionization-inducing absorption wave with a front traveling at the rate governed by the electron component of the thermal conductivity.
1984-04-01
Mammary carcinogenesis in the rat after low-dose irradiation
International Nuclear Information System (INIS)
Carcinogenesis is now generally recognized to be an important detrimental effect in man after low dose irradiation. The carcinogenic action of ionizing radiation is clearly demonstrated after exposure to relatively high doses (in excess of 0.5 Gy) but for lower dose levels reliable direct observations are not available. With the introduction of special protocols for the performance of large scale screening programs by mammography the average absorbed dose in glandular tissue in the average breast can be restricted to a value of 3 mGy per mammogram. The risk for tumor induction after exposure to these low doses can never be established from human epidemiology. In order to investigate the risk of repeated exposure to small dose of ionizing radiation the induction of mammary tumors has been investigated in rats of the WAG/Rij strain after single and fractionated irradiations with gamma-rays. (author). 8 refs., 3 figs.
1992-07-12
Ionizing radiation is a potent inducer of mitotic recombination in mouse embryonic stem cells
British Library Electronic Table of Contents (United Kingdom)
Maintenance of genomic integrity in embryonic cells is pivotal to proper embryogenesis, organogenesis and to the continuity of species. Cultured mouse embryonic stem cells (mESCs), a model for early embryonic cells, differ from cultured somatic cells in their capacity to remodel chromatin, in their repertoire of DNA repair enzymes, and in the regulation of cell cycle checkpoints. Using 129XC3HF1 mESCs heterozygous for Aprt, we characterized loss of Aprt heterozygosity after exposure to ionizing radiation. We report here that the frequency of loss of heterozygosity mutants in mESCs can be induced several hundred-fold by exposure to 5-10Gy of X-rays. This induction is 50-100-fold higher than the induction reported for mouse adult or embryonic fibroblasts. The primary mechanism underlying the...
2011-01-01
Ionized gas and radio emission in the barred Seyfert galaxy NGC 5728
International Nuclear Information System (INIS)
This paper reports extensive new optical and radio observations of NGC 5728, emphasizing the central regions. Deep photographs revealing detail in the faint spiral arms are briefly discussed. Broad-band UBV CCD images obtained to examine the colors of the stellar populations that comprise the bar and central ring are presented. The velocity field and emission maps obtained from imaging spectroscopic measurements in the H-alpha emission line are discussed. Conventional long-slit spectra covering the ionized gas in the nuclear region are described. Detailed maps of the radio emission in the central regions of NGC 5728 are presented. These combined data provide considerable evidence for the inflow of gas into the nuclear region, in response to the nonaxisymmetric gravitational potential of the bar. The possible relation of this phenomenon to the Seyfert nature of NGC 5728 is also considered. 48 references.
International Nuclear Information System (INIS)
The main objectives of research in the field of health effects at the Belgian Nuclear Research Centre SCK-CEN are: (1) to study cancer mortality and morbidity in nuclear workers in Belgium; (2) to document the feasibility of retrospective cohort studies in Belgium; (3) to participate in the IARC study; (4) to elucidate the mechanisms of the effects of ionizing radiation on the mammalian embryo during the early phases of its development; (5) to assess the genetic risks of material exposure to ionizing radiation; (6) to elucidate the cellular mechanisms leading to brain damage after prenatal irradiation; (7) to advise authorities and to provide the general population with adequate information concerning the health risk arising from radiation exposure. Progress and major achievements in these topical areas for 1997 are reported.
Effect of ionizing radiation on the properties of PLA packaging materials
International Nuclear Information System (INIS)
Poly(lactic acid) (PLA) is attractive as a substitute for classical polymer packaging material due to its biodegradability and sufficient mechanical and barrier properties. Presented research was focused on the changes of basic mechanical parameters after ionizing irradiation performed with doses in the range of 2.5-25 kGy, commonly used in radiation sterilization and preservation of foods. Two commercial available PLA packaging films were tested. The influence of radiation dose on the mechanical properties - tensile strength and elongation were determined using standardized methods. Radiation resistance of PLA is sufficient for packaging applications. The investigations of gas products of radiolysis of PLA have been made by gas chromatography after electron beam (EB) irradiations. (authors)
Detection of irradiated chicken by ESR spectroscopy of bone
Energy Technology Data Exchange (ETDEWEB)
Ionizing radiation has been used to treat poultry to remove harmful microorganisms, mainly Salmonella, which contaminates chicken, goose and other fresh and frozen poultry. This microorganism is sensitive to low dose radiation. Thus, irradiating these foods with doses between 1 to 7 kGy results in a large reduction of bacteria. Since it is necessary to determine whether irradiation has occurred and to what extend, this work studied the signal produced by ionizing radiation within the hard crystalline matrix of chicken`s bone to establish a control method. Chicken`s drumsticks were irradiated and bones separated from flesh were lyophilized and milled. ESR spectrum was then obtained. The ESR signal increased linearly with dose over the range 0.25 to 8.0 kGy. Free radicals evaluated during 30 days after irradiation showed stable in this period. (Author).
1995-10-01
British Library Electronic Table of Contents (United Kingdom)
Photoelectron resonance capture ionization aerosol mass spectrometry (PERCI-AMS) has been applied to the analysis of proxies for marine aerosols with and without ozone; proxies used were mixed oleic acid-amino acid particles. The mechanism of ion formation for serine (104 m/z), glutamic acid (146 m/z), and phenylalanine (164 m/z) was dissociative electron attachment. This corresponds to loss of the hydrogen atom only, allowing for straightforward identification of the free amino acids. No ozonolysis products for the free amino acids were observed, even at high concentrations of ozone (500 ppm for 19 s). The direct detection of a novel gas-phase hydrated anion, [serine + H2O-H]-, is described. These preliminary results suggest that PERCI-AMS may provide an effective, simple and direct onlin...
2008-01-01
Correlation effects in partially ionized mass asymmetric electron-hole plasmas
The effects of strong Coulomb correlations in dense three-dimensional electron-hole plasmas are studied by means of unbiased direct path integral Monte Carlo simulations. The formation and dissociation of bound states, such as excitons and bi-excitons is analyzed and the density-temperature region of their appearance is identified. At high density, the Mott transition to the fully ionized metallic state (electron-hole liquid) is detected. Particular attention is paid to the influence of the hole to electron mass ratio $M$ on the properties of the plasma. Above a critical value of about M=80 formation of a hole Coulomb crystal was recently verified [Phys. Rev. Lett. {\\bf 95}, 235006 (2005)] which is supported by additional results. Results are related to the excitonic phase diagram of intermediate valent Tm[Se,Te], where large values of $M$ have been observed experimentally.
2007-01-01
Comparative evolution of various CCD image sensors hardening techniques with ionizing radiation
International Nuclear Information System (INIS)
This paper reviews various techniques to harden Charged Coupled Device (CCD) sensors and the results after irradiation of three Thomson n buried channel CCDs having a different degree of hardening. It describes the major irradiation effects on CCD performances and it makes a comparison of the results between the different hardening levels. It shows good results on dark voltage after ionizing radiation for TH 7863M device hardened both by design and by operating conditions (MPP mode) with respect to the standard device TH 7863A. The irradiations were performed with "6"0Co or X-ray (10 keV) sources on devices in operating mode. (author). 3 refs., 8 figs.
Atomic processes in high temperature plasmas
International Nuclear Information System (INIS)
Much theoretical and experimental efforts have been expended in recent years to study those atomic processes which are specially relevant to understanding high temperature laboratory plasmas. For magnetically confined fusion plasmas, the temperature range of interest spans from the hundreds of eV at plasma edges to 10 keV at the center of the plasma, where most of the impurity ions are nearly fully ionized. These highly stripped ions interact strongly with electrons in the plasma, leading to further excitation and ionization of the ions, as well as electron capture. Radiations are emitted during these processes, which easily escape to plasma container walls, thus cooling the plasma. One of the dominant modes of radiation emission has been identified with dielectronic recombination. This paper reviews this work.
1990-01-01
The method and results of measurements of "2"2"2Rn emanation from building materials
International Nuclear Information System (INIS)
The method and results are presented of measurements of the coefficients of "2"2"2Rn emanation from samples of fly- ashes and slag and other commonly used building materials. A chamber was used for electrostatic collection of "2"2"2Rn decay products. The coefficients of emanation ranged from 0.2% (fly- ashes) to 21.3% (phosphogipsum from phosphorit). (author).
1979-01-01
The adiabatic engine:Global developments
Energy Technology Data Exchange (ETDEWEB)
This book presents papers on internal combustion engines. Topics considered include the influence of partial suppression of heat rejection on performance and emissions, duothermic combustion, turbochargers made of sintered silicon nitrides, heat flux, low heat rejection engines, exhaust energy recovery, combustion chamber insulation, computerized simulation, heat transfer, friction, hoop stress effects, and bonding ceramics and metals.
1986-01-01
Radon measurements in the interior of the great pyramid
Energy Technology Data Exchange (ETDEWEB)
Radon concentration measurements were made in the interior of the great pyramid of ''Cheops'' at Giza. Measurements were carried out using CR-39 as a solid state nuclear track detector. The CR-39 sheets were placed inside the Queen's and King's chambers and along the ascending corridor leading to them. An evaluation of the radon concentration is presented and discussed. (author).
1991-01-01
Radon measurements in the interior of the great pyramid
International Nuclear Information System (INIS)
Radon concentration measurements were made in the interior of the great pyramid of ''Cheops'' at Giza. Measurements were carried out using CR-39 as a solid state nuclear track detector. The CR-39 sheets were placed inside the Queen's and King's chambers and along the ascending corridor leading to them. An evaluation of the radon concentration is presented and discussed. (author).
Radon concentration measurements in the soil
International Nuclear Information System (INIS)
Radon concentration measurement in the ground can be used for the prospecting for uranium and earthquake prediction. Some results of radon concentration measurement in the soil are presented here. The moisture condensation at the detector surface can affect on the detection efficiency. Due to this problem we tested a few filter papers on water permeability. The ratio of track densities on solid state nuclear track detector (SSNTD) in the open and the closed diffusion chamber is also determined. (author)
Radiation doses and somatic risk to patients during cardiac radiological procedures
International Nuclear Information System (INIS)
The radiation dose to a series of adult and paediatric patients undergoing cardiac catheterisations and adults having percutaneous transluminal coronary angioplasty has been measured/determined directly using lithium fluoride thermoluminescent dosemeters and indirectly using an air ionisation chamber which indicated exposure-area product. Somatic and genetic risks are estimated from the dosimetry results. It is suggested that the magnitude of the radiation hazard is negligible compared with other clinical hazards associated with these procedures. (author).
1986-01-01
Prototype exposure chamber of radon for animal experiments
Energy Technology Data Exchange (ETDEWEB)
To evaluate a dose conversion factor from the `Working Level of Month` (WLM) of radon to the absorbed dose (mGy), the quality of radon and its progeny was assessed, and exposures controlled for each deposition region were planed as follows: 1) exposure of radon gas to the entire respiratory tract, 2) exposure of `unattached` fractions to the upper respiratory tract, 3) exposure of `attached` fractions onto ultrafine particles to the deep lung, 4) exposure of `attached` fractions onto fine particles to the lower respiratory tract, 5) exposure of `attached` fractions onto coarse particles to the upper respiratory tract. In this preliminary study, a prototype exposure system of radon and its progeny for small rodents was designed. A whole body exposure chamber with a volume of about 0.5 m{sup 3} was used, which it held 20 rats. The aging and mixing chamber separated by the exposure chamber had a volume of about 1 m{sup 3}. As ...
1998-12-31
Proceedings of the meeting on the technical study at KEK
International Nuclear Information System (INIS)
Technical studies on constructing the J-PARC (Japan Proton Accelerator Research Complex) are presented by five authors: (1) on the wiring for electromagnets of the 50 GeV synchrotron, (2) on the fast beam-extraction from the 50 GeV synchrotron into two opposite directions, (3) on the target chamber system for the generation of muons, (4) on the design of large aperture electromagnets, and (5) on the maintenance and control of the electromagnet power supplies. (K.Y.)
2006-11-28
Photosynthesis and Growth of Water Hyacinth under CO2 Enrichment 1
UK PubMed Central (United Kingdom)
Water hyacinth (Eichhornia crassipes [Mart.] Solms) plants were grown in environmental chambers at ambient and enriched CO2 levels (330 and 600 microliters CO2...Full Text Available
1986-10-01
PIV measurements of flow structures in a spray dryer
DEFF Research Database (Denmark)
Stereoscopic Particle Image Velocimetry (PIV) measurements are made in horizontal planes in a simplified scale model of a spray dryer using water as fluid. The sample rate was sufficient to resolve phenomena at lower frequencies. Data reveal asymmetric velocity fields in both mean fields and dynamics. Data were analysed using Proper Orthogonal Decomposition (POD). An important periodic event is an elongation of the jet core cross section that results in a downstream displacement of the jet towards the chamber wall.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
MPFDs are a new class of detectors that utilize properties from existing radiation detector designs. A majority of these characteristics come from fission chamber designs. These include radiation hardness, gamma-ray background insensitivity, and large signal output.
2006-06-12
Modelling of the wall jet in a direct injection diesel engine
Energy Technology Data Exchange (ETDEWEB)
As a part of a phenomenological model, a method for simulating the wall/jet interaction in a direct injection diesel engine is proposed. The method is based on the application of the momentum conservation equation in the different directions in which the wall jet is spread, and takes into account both the interaction with the combustion chamber geometry and with swirl. It takes as initial conditions the results of calculating the free jet, which is divided into packages. The predictions provide good agreement with those by other researchers. (author).
1992-01-01
Medical explorations by radioisotopes in Lebanon
International Nuclear Information System (INIS)
This study mainly concerns medical explorations by radioisotopes. Detectors with medical exams and applications are described. Ionisation chambers, semiconductor detectors and scintillation counters are also presented. Uses of radioisotopes in medicine in vivo and in vitro techniques are explained. Examples of scintiscanning are given like: angiography, nuclear cardiography and thyroid scintiscanning. The importance of the study is to present a panorama of nuclear medicine laboratories -at the time- in hospitals in Lebanon.
Core power distribution measurement and data processing in Daya Bay Nuclear Power Station
International Nuclear Information System (INIS)
For the first time in China, Daya Bay Nuclear Power Station applied the advanced technology of worldwide commercial pressurized reactors to the in-core detectors, the leading excore six-chamber instrumentation for precise axial power distribution, and the related data processing. Described in this article are the neutron flux measurement in Daya Bay Nuclear Power Station, and the detailed data processing.
Transformation of the ATOMKI-ECRIS into a Plasma Device
International Nuclear Information System (INIS)
Complete text of publication follows. In order to extend the capabilities of the electron cyclotron resonance (ECR) ion source (ECRIS) of ATOMKI it has been transformed into a special plasma facility [1,2]. The transformation is reversible and was simply done by changing several main components of the ion source by new ones, namely: the hexapole magnet, the plasma chamber and the microwave source. The basic requirements of the transformation were: (1) most parts of the present ECRIS should be used in the new assembly in the same way and (2) the transformation time between the two operation modes should not be more than 2-3 days (in both directions). The following sub-systems are used identically in both configurations: solenoid coils, vacuum system, gas dosing system, ovens, probes. The extraction optics and beam transport system can also be used in the new configuration to check the components and charge-state of the plasma. A new, large, but unusually thin ...
2006-01-01
UK PubMed Central (United Kingdom)
The titers of several preparations of kuru. Creutzfeldt-Jacob disease, and scrapie viruses were reduced by only 1/10th or less by high doses of gamma radiation of 50 kGy and by only 1/10th-1/1000th...Full Text Available
1978-12-01
Total dose hardening of SIMOX buried oxides for fully depleted devices in rad-tolerant applications
International Nuclear Information System (INIS)
A total dose hardening treatment is applied to SIMOX buried oxides. Total ionizing dose radiation testing is performed on fully-depleted transistors fabricated on both hardened and non-hardened substrates. At 200 krads x-ray dose, the front gate shift is reduced from -0.7 to -0.2 V for FETs built on the hardened wafers.
1996-07-15
Spontaneous radiation decay of weakly bound system in externa field
International Nuclear Information System (INIS)
A new channel of nonlinear ionization of quantum system in a strong laser field is discussed. The probability of spontaneous radiation decay from the ground state in a short-range potential to the final Volkov wave function, is calculated by the first order of the perturbation theory. It is shown that this process at high intensities of the laser field will be comparable with the high harmonic generation. (orig.)
2001-02-01
Sources of X-rays in school; Zrodla promieniowania rentgenowskiego w szkole
Energy Technology Data Exchange (ETDEWEB)
Exposure of teachers of physics to X-radiation emitted by instruments which are used for demonstrating rarefied gas discharges during physics lessons at secondary schools is discussed. The measurements performed provide an explicit evidence that an effective, annual exposure dose under the most unfavorable conditions does not exceed admissible levels according to Polish regulations pertaining to persons non-occupationally exposed to ionizing radiation. (author). 3 refs,1 fig.
1996-12-31
Self-simulating motion of an ionized gas expelled by a magnetic piston
Energy Technology Data Exchange (ETDEWEB)
The paper deals with a model in which the motion of a gas in plasma accerators and high-curent discharges in the present of a skin effect is treated as expulsion by a 'magnetic piston' under the action of surface current flow. Specifically examined is the situation where the initial gas pressure is negligible in comparison with the magnetic pressure, and the motion of the gas may be treated as a self-simulating one. A system of hydrodynamic equations of the problem is derived and integrated by Adam's method. Results are plotted and discussed.
1980-01-01
Searches for Fast Radio Transients
We discuss optimal detection of fast radio transients from astrophysical objects while taking into account the effects of propagation through intervening ionized media, including dispersion, scattering and scintillation.Our analysis applies to the giant-pulse phenomenon exhibited by some pulsars, for which we show examples, and to radio pulses from other astrophysical sources, such as prompt radio emission from gamma-ray burst sources and modulated signals from extra-terrestrial civilizations.
2003-01-01
Room air quality. Raumluftqualitaet
Energy Technology Data Exchange (ETDEWEB)
Room air quality and thus thermal comfort for the occupiers in closed spaces depend on several factors: temperature and humidity of the air, temperature of the surrounding surfaces, content of foreign matter of the air, acoustical perceptions, electric fields and ions as well as colours and light. Air humidification, cleaning and ionization largely contributes to improved room air quality. The article goes into problems of too dry and polluted air as well as into measures with which these problems can be solved. (BWI).
1990-12-01
Energy Technology Data Exchange (ETDEWEB)
It may be necessary to reduce microbiological contamination of crude drugs (medicinal plants or their parts like roots, leaves, flowers). This can be done by treating the drugs with ionizing radiation. Meethods for detection of such an irradiation were developed. It could be pointed out that measurements of luminescence, viscosity and electron spin resonance were suitable for specific drugs, but not for all drugs. (orig.).
1992-09-01
Radiation higienization possibility and perspectives
International Nuclear Information System (INIS)
Food irradiation is the process of exposing food to an ionizing energy to kill harmful bacteria and other organisms and extend shelf-life. It is a safe process and has been approved by some 50 countries worldwide and applied commercially in the USA, Japan, China and several European countries for many years. Trends law regulations and new applications in Europe and another countries has been described. (author)
2005-09-07
Radiation hazards from medical applications
International Nuclear Information System (INIS)
An introduction is presented on the radiation hazards connected with biomedical radiography and nuclear medicine. The frequency of radiodiagnostic efforts was rather high in the Netherlands. This was reduced considerably by abolishing the thorax screening of the population. About diagnostic nuclear medicine less can be said because far fewer numerical data are available. An exposition of genetically and somatically significant doses and how to compute them is given. The drawing up of a profit versus risk evaluation for medical applications of ionizing radiations is recommended. (Auth.).
1980-05-31
Physics of thermal gaseous nebulae
Energy Technology Data Exchange (ETDEWEB)
Much of the material presented in this book derived originally from the series ''Physical Processes in Gaseous Nebulae'' initiated at the Harvard College Observatory in the 1930's. The subject of gaseous nebulae, which offers opportunities for studies of stellar evolution, should be of interest to atomic physicists, spectroscopists, plasma experts, and to observers and theoreticians alike for the study of attenuated ionized gases.
1984-01-01
Normal and abnormal neuronal migration during brain development
International Nuclear Information System (INIS)
Conceptual and factual advances in understanding neuronal migration in the past two decades have provided new insight into the pathogenesis of brain malformations at the cellular, molecular, and functional levels. Some of these results may have direct implications in understanding the consequences of ionizing radiation on the fetal central nervous system in utero. (orig.).
Molecular events involved in ionizing radiation induced skin carcinogenesis
International Nuclear Information System (INIS)
The process of mouse skin tumor formation is subdivided into three operational stages. These stages include initiation, promotion and progression. Ionizing radiation has been found to be a weak initiating agent in the production of malignant squamous cell carcinomas, a complete carcinogen and an agent effective in causing tumor progression. Four skin tumor histologies have been seen with ionizing radiation: benign papillomas, squamous (SCC) and basal (BCC) cell carcinomas and fibrosarcomas. Distinct non-ras transforming genes have been detected in radiation initiated SCCs. A benign papilloma cell line (308) was used as a model system to study ionizing radiation induced progression. A variant 308 cell line (308 10 Gy 5) derived by irradiation of the parental 308 cell has been characterized. The 308 10 Gy 5 cells unlike the parental 308 cells from malignant tumors in athymic nude mice upon subcutaneous injection. The variant ...
Lamp system for uniform semiconductor wafer heating
Energy Technology Data Exchange (ETDEWEB)
A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.
2001-01-01
Highly efficient ion source for analysis of transuranium elements
Energy Technology Data Exchange (ETDEWEB)
Results are described of the study of the analytical applicability of a highly efficient ion source developed for a mass spectrometer. Its ionizer is in the form of a partially closed cavity with a small aperture for leading out ions, heated to a high temperature. The new ion source increases the sensitivity of the apparatus in operations with transuranium elements by almost two orders of magnitude. It is possible to perform isotopic analyses with a high salt content in the sample, and to study the characteristics of nuclear fuel, even without chemical separation of the sample elements.
1987-01-01
Efficient higher-order derivatives of the hypergeometric function.
Energy Technology Data Exchange (ETDEWEB)
Various physics applications involve the computation of the standard hypergeometric function {sub 2}F{sub 1} and its derivatives. Because it is not an intrinsic in the common programming languages, automatic differentiation tools will either differentiate through the code that computes {sub 2}F{sub 1} if that code is available or require the user to provide a hand-written derivative code. We present options for the derivative computation in the context of an ionization problem and compare the approach implemented in the Diamant library to standard methods.
2008-01-01
International Nuclear Information System (INIS)
The decree refers to conditions of irradiation of food and its components for radappertization and radurization using gamma radiation from cobalt 60 or cesium 137, X radiation or electron beam up to maximum total medium absorbed dose 10 kGy.
2003-03-04
Bragg curve spectroscopy in a 4? geometry
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4? geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon.
1991-02-01
Bragg curve spectroscopy in a 4. pi. geometry
Energy Technology Data Exchange (ETDEWEB)
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4{pi} geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).
1991-02-01
Bragg curve spectroscopy in a 4#pi# geometry
International Nuclear Information System (INIS)
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4#pi# geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).
Biological effects and health risks following to the exposition to ionizing radiation
International Nuclear Information System (INIS)
Late somatic and genetic radiation effects are imperfectly understood, particularly in the human species. However the available information is sufficient to draw reasonably precise risk estimates in man for many types of damage by means of scientifically justifiable procedures and with the necessary caution. This overall absolute risk of major somatic and genetic damage may be set at around 10"-"4/rad of chronic whole-body doses.
1976-01-01
Adiabatic theory of Wannier threshold laws and ionization cross sections
Energy Technology Data Exchange (ETDEWEB)
The Wannier threshold law for three-particle fragmentation is reviewed. By integrating the Schroedinger equation along a path where the reaction coordinate R is complex, anharmonic corrections to the simple power law are obtained. These corrections are found to be non-analytic in the energy E, in contrast to the expected analytic dependence upon E.
1994-12-31
Adiabatic angular wave functions in the atomic ionization proplem
Energy Technology Data Exchange (ETDEWEB)
Angular wave functions are investigated which describe the motion of two electrons in the field of a nucleus at fixed equal distances from electrons to the nucleus. Calculation methods are considered that include matching of power series and expansion in series of Legendre polynomials. Asymptotic properties of solutions at small large distances are determined.
1984-01-01
Energy Technology Data Exchange (ETDEWEB)
A simple and continuous model for the on-state current of polysilicon thin-film transistors, suitable for implementation in circuit simulators, is presented. The model includes the potential barrier at the grain boundaries, the channel length modulation and the excess current due to impact ionization. Comparison between measured output characteristics and the model shows excellent agreement over wide range of bias voltages and for devices with different gate lengths.
2005-01-01
Low temperature partly ionized plasma in magnetic fusion devices: Present status and prospects
Energy Technology Data Exchange (ETDEWEB)
The most striking achievement in magnetic fusion experiments during last few years was the discovery of plasma detachment from material targets, a much needed effect for plasmas with high power fusion parameters. Due to the very low heat loads on the targets observed in these regimes and potentially low erosion of the targets, detached regimes look attractive from the International Thermonuclear Experimental Reactor (ITER) design point of view. Thus the author has experimental proof for the possibility for a co-existence of fusion relevant hot plasma in the core and a low temperature partly ionized plasma at the edge of magnetic fusion device. Although somewhat similar behavior of edge plasma was considered theoretically even before plasma detachment was found experimentally, it was not clear in the beginning how these theoretical and experimental findings would fit together. Now, after a few years of intensive additional experimental and theoretical studies, a ...
1998-12-31
Energy Technology Data Exchange (ETDEWEB)
Discussions were given on the characteristics of a diesel engine to emit unburned hydrocarbon (HC) created in a long idling operation. The engine tested in the experiment is a direct injection diesel engine with six water-cooled were investigated varying the jet hole diameter and length of the jet nozzle. In the initial operation period, the HC showed high values. This is thought because part of the injected fuel has deposited on the wall because of low combustion chamber wall temperature, and the fuel deposit that did not evaporate during combustion evaporated during expansion process and emitted unburned. The head was dismantled to investigate the carbon flowers deposited on the nozzle and the relationship between the carbon and the HC deposited on the head face and the combustion chamber wall. It was clarified that the HC increase was phenomenal compared with that of the carbon. This is because the injected fuel was adsorbed into the carbon, ...
1992-04-01
Energy Technology Data Exchange (ETDEWEB)
Today, as a result of increase in oil prices, limited fossil fuel resources, environmental consideration and global warming, the methyl ester fuels have been focused on alternative fuels. Methyl ester fuels can be used more efficiently in low heat rejection engines (LHR), in which the temperature of combustion chamber is increased by creating a thermal barrier. In this study, the piston, cylinder head, exhaust and inlet valves of a diesel engine were coated with the ceramic material Al{sub 2}O{sub 3}-TiO{sub 2} by the plasma spray method. Thus, a thermal barrier was provided for the parts of the combustion chamber with these coatings. The effects of corn oil methyl ester that produced by the transesterification method, and No. D2 fuels' performance and exhaust emissions' rate were studied by using equal in every respect coated and uncoated engines. Tests were performed on the uncoated engine, and then repeated on the coated ...
2010-10-15
Studies on the interaction of lidocaine with plasma proteins
Energy Technology Data Exchange (ETDEWEB)
This study sought to quantitate lidocaine's interaction with alpha-1-acid glycoprotein (AAG), human serum albumin (HSA), and AAG in the presence of HSA, and to determine the extent of displacement of lidocaine from its binding site(s) by selected cardiovascular drugs (dipyridamole, disopyramide and quinidine). Since the limited experimental work reported in this area has involved the use of a single lidocaine concentration, this study involved the evaluation of a range of lidocaine concentrations. Lidocaine interaction with plasma proteins (AAG and HSA) was studied at 37/sup 0/C using an isothermal equilibrium dialysis system and /sup 14/C-lidocaine HCl. A dialysis membrane (M.W. cutoff 12,000 to 14,000) separated the two chambers of each dialysis cell. The extent of /sup 14/C-lidocaine dialysis was studied with respect to both drug and protein concentrations. Aliquots of each chamber of each of the cells were subjected to liquid ...
1985-01-01
Spray evaporation in direct-injection diesel engine
Energy Technology Data Exchange (ETDEWEB)
A theoretical model for spray evaporation in a direct-injection diesel engine is developed taking into consideration the unsteady evaporation period. For this purpose, the liquid droplets temperatures, masses and velocities are studied. Solving the conservation of energy and mass equations together with the equation of state, a set of ordinary differential equations is achieved. These equations are solved using a special numerical technique. This technique, based on a fourth-order Runge-Kutta integration method is described. Calculated results are compared with experimental data and were found to be in good agreement. Analysis of the obtained results shows that for the combustion-chamber constituents, temperature is a dominant factor in the spray-evaporation process and in shaping the temperature history of the evaporating droplets. The combustion-chamber pressure and the spray volume play a secondary role in the evaporation process. Also, it ...
1987-01-01
Roof slab cooling device in a FBR type reactor
International Nuclear Information System (INIS)
Purpose: To obtain a roof slab cooling device capable of retaining cooling performance even in a case of electric power supply stop or failure and effective from economical point of view. Constitution: Atmospheric air is introduced into the cooling chamber of a proof slab and spontaneously passed to a exit pipeway connected to a stack thereby cooling the roof slab. Specifically, atmospheric air entered from the inlet pipeway is introduced to the cooling chamber and absorbs heat generate from the inside of the reactor container. Warmed air is sucked from the exit pipeway and then released into the atmosphere passing through the stack. The air cools the roof slab during circulation due to spontaneous passage and keeps the slab at a low temperature. Since the air is passed spontaneously, no power such as for a blower is required at all and, if the electric power supply should be lost, the cooling power can be maintained as it is to provide a high ...
1986-05-16
Remodeling of the free electron laser with the L-band linac at Osaka University
International Nuclear Information System (INIS)
The far infrared free electron laser (FEL) has been being developed since 1990 using the L-band electron linac at the Institute of Scientific and Industrial Research, Osaka University. The first lasing was obtained in 1994 at wavelengths from 32 to 40 #mu#m. The FEL is now being modified suitable for user experiments. The wiggler with a fixed magnet gap used in the original FEL has been remodeled to make the magnet gap variable. In order to optimize the variable range of the gap, the gain and the diffraction loss were calculated. The peak gain is calculated to be 270% and the diffraction loss to be 22% at 150 #mu#m. The wavelength is expected to be variable from 25 up to at least 150 #mu#m. The two bending magnets in the optical resonator have been remodeled and the vacuum chambers with larger vertical sizes for them have been newly made so that the diffraction loss in these parts becomes smaller than that in the vacuum chamber of the wiggler. ...
1997-02-28
Reduction of combustion emissions using hydrogen peroxide in a pilot scale combustion chamber
Energy Technology Data Exchange (ETDEWEB)
A hydrogen peroxide injection system was designed and installed in the stack of a 5,274 million J/hr industrial pilot plant scale combustion chamber using natural gas as fuel. The concentration of peroxide in the gas stream was precisely controlled by continuous injection using an electromagnetic dosage pump, the liquid 50% peroxide solution was finely dispersed into the gases by a water cooled custom designed delivery system with a spray nozzle at the tip. Residence times between 0.1 and 1.8 seconds and concentrations of H{sub 2}O{sub 2} between 280 ppm and 4,000 ppm were used during the test runs. CEMS for total hydrocarbons, carbon monoxide, nitrogen oxides, as well as an ultrasonic gas flow monitor were used to measure the effect of hydrogen peroxide in reducing the emissions of these pollutants. Destruction removal efficiencies between 25% and 100% were observed for hydrocarbons, and concentrations of CO, as well as NO{sub x}. were reduced about 50%. The ...
1997-12-31
Recent development in Mitsui B and W type gas injection diesel engine
Energy Technology Data Exchange (ETDEWEB)
A gas injection diesel engine was developed as an approaching measure to the diversification of fuel. Contrary to the usual low pressure gas application engine, this engine applies a so-called diffuse combustion method, in which high pressure (24.7Mpa) gas fuel is injected directly in the cylinder and is ignited and combusted by a little pilot fuel injected almost at the same time. The engine have following features. As a principle, it can attain the same heat efficiency and output rate as a diesel engine in any load range. It is excellent in responsibility to load fluctuation. There is no internal leakage of gas fuel to the scavenging chamber (the crank chamber) in the compression stroke. Not only a wide range of mixed combustion of gas fuel and heavy oil fuel, but also single combustion of heavy oil is possible. It is, therefore, drawing attention as an engine for an LNG ship and also for a power generation plant with the recent increasing ...
1988-12-01
Energy Technology Data Exchange (ETDEWEB)
Plasma nitriding of a Ti substrate is carried out under a low ambient pressure below 3kPa, and a plasma torch is prepared on a trial basis which is provided with a supersonic expansion nozzle considered to expand plasma jet optimally and to be effective for suppressing the occurrence of shock wave. The system used for the study is provided with a specimen holder having the function of adjusting the distance between the nozzle outlet and the substrate inside the vacuum chamber which is provided with a plasma torch in the flange member. The plasma torch is so structured that a supersonic expansion nozzle can be installed at the tip of the plasma torch. In this process wherein plasma jet is employed, hard nitrided layer can be formed by plasma irradiation for a short time even under such low pressure as less than 3kPa by setting adequate experimental conditions. It is made clear that the use of a supersonic nozzle corresponding to the internal pressure of the ...
1997-07-01
International Nuclear Information System (INIS)
The performance of the gas-jet transport system coupled to the RIKEN gas-filled recoil ion separator GARIS was investigated using 255No produced in the 238U(22Ne, 5n)255No reaction. Alpha particles of 255No separated with GARIS and transported by the gas-jet system were measured with a rotating wheel apparatus for ? spectrometry under low background condition. The high gas-jet efficiencies of about 75% were independent of the recoil ranges of 255No in the gas-jet chamber. The present results suggest that the GARIS/gas-jet system is a promising tool for the next-generation superheavy element chemistry: (1) the background radioactivities of unwanted reaction products are strongly suppressed, (2) the intense beam is absent in the gas-jet chamber and hence the high gas-jet efficiency is achieved, and (3) the beam-free condition also allows for investigations of new chemical systems. (author)
2008-08-01
Energy Technology Data Exchange (ETDEWEB)
This paper reports on the generator condition monitor (GCM) developed in an attempt to detect overheating inside large turbine generators. As part of a broader study on rotating machinery diagnostics, generator condition monitors were evaluated under field conditions in a 550 MW turbogenerator. Small 100 W resistors coated with insulating paints and varnishes were mounted inside the generator to simulate insulation overheating. The GCM responded very rapidly to an overheating event, typically within two minutes, even for hot spots as small s 10 cm{sup 2}. Similarly the aerosols produced on overheating were found extremely short lived, decaying within two to three minutes after overheating was discontinued. Use of heated ion chambers was found to desensitize the GCM regardless of the nature of the overheated insulation and in some cases would altogether prevent the GCM from reaching the 50% pre-set alarm level commonly used on GCMs.
1990-06-01
Energy Technology Data Exchange (ETDEWEB)
This report compares the performance characteristics of /sup 10/B-lined and fission-neutron detectors in gamma-ray fluxes typical of the fields to be encountered during nondestructive testing of irradiated light-water fuel assemblies stored in water. Using the optimum time constants for each of the /sup 10/B-lined detectors, the 0.25-in.-dia detector had a 5% loss in neutron count sensitivity at 7000 rad/h. Similarly, the 0.5-in.-dia detector had a 7% loss at 13,000 rad/h and the 1-in.-dia detector had a 5% loss in sensitivity at 1000 rad/h. Uranium-235 fission chambers were operated successfully in fields above 100,000 rad/h with no loss in neutron counting sensitivity. Shielding calculations were done to determine the appropriate shield thickness needed for a /sup 10/B-lined neutron detector to operate in a 50,000 rad/h field, typical of light-water-reactor spent-fuel assemblies stored in water. 7 refs., 4 figs., 9 tabs.
1985-03-01
Measuring characteristics on emissivity using infrared thermometer for RCCS
International Nuclear Information System (INIS)
In VHTGR (Very High Temperature Gas-cooled Reactor), the radiation plays an important role in heat transfer through the cavity in RCCS (Reactor Cavity Cooling System). We performed the series of experiments to measure the emissivity using the infrared thermometer with wavelength range of 8#approx#14 #mu#m. As the first step, the transmittance of Zinc Selenide (ZnSe) window was measured to estimate the emissivity that can compensate the attenuation effect of window. The kind of gas with various concentrations in the cavity will be released during postulated accidents to the coolant type, so it is essential to estimate the effects of gas on the measurement of emissivity. In this manner we measured the emissivity with the air, the helium and the steam inside chamber. The results represent that the concentration of the air and the helium do not affect the emissivity significantly while the steam decreases the measured emissivity relatively. It means that the air and ...
2004-12-01
Measurement of the "1"0"9Cd half-life
International Nuclear Information System (INIS)
The half-life of "1"0"9Cd was measured by following the decay of sources from a radiochemically pure solution with two different measuring systems: an ionisation chamber and a high-purity germanium (HPGe) detector. The measurements were performed over a period of 3.6 years, i.e. about 2.8 half-lives of "1"0"9Cd. The resulting half-life values and detailed uncertainty budgets (k=1) are presented for both systems. The result obtained with the ionisation chamber, 462.36 (33) days, and the one obtained with the HPGe detector, 461.92 (76) days, are mutually consistent. The weighted mean of our measured values, T_1_/_2("1"0"9Cd)=462.29 (30) days, is consistent with the currently recommended values of 461.4 (12) days and 462.0 (3) days. From a set of selected experimental values published after 1970, a 'partially weighted mean' of T_1_/_2("1"0"9Cd)=462.36 (39) days was calculated. More measurements are needed to resolve the discrepancies among ...
2011-05-01
Energy Technology Data Exchange (ETDEWEB)
Swirling flow in a direct injection diesel engine was measured by a laser doppler velocimeter. Piston cavity diameter and top clearance volume were changed as factors affecting swirling flow to study the distribution of swirling flow speed. When using the same intake port and changing the opening ratio of piston cavity, the distribution of swirling flow speed was different by the cavity during intake process but these agree just after opening intake valve and then become again different by cavity. When increasing top clearance and decreasing compression ratio, the axial symmetry of flow during commpression process increases. When changing piston cavity, and also when changing intake port, the mean swirling ratio in inside and outside areas of combustion chamber has common tendency to increase and decrease respectively. The mean swirling flow in the combustion chamber may be capable to be predicted by devising a model which can describe this ...
1989-05-31
Energy Technology Data Exchange (ETDEWEB)
The effectiveness of Noveko's antimicrobial filter was evaluated after 16 months of exposure to commercial swine production. The experiment involved the use of a scaled model of a commercial swine facility consisting of 2 small chambers connected by a duct containing the filters. A 5 kg naive pig was placed in the reception chamber for a period of 6 hours after aerosolization with porcine reproductive and respiratory syndrome virus (PRRSV). Blood samples from pigs were collected before and after aerosolization to test for the presence of PRRSV RNA. Only blood samples were tested for PRRSV antibodies by IDEXX 2XR ELISA. None of the 9 pigs tested were found to be infected. The study showed that the technology used to integrate the antimicrobial agent into the filter fibers allows the filter combination to withstand extreme weather and endure commercial swine production for at least 16 months, and can maintain its effectiveness to avoid ...
2010-07-01
Development status of a small, direct-injection diesel engine at Isuzu
Energy Technology Data Exchange (ETDEWEB)
Development status of small direct injection diesel engine at Isuzu Motors Ltd. is reviewed. There is much difficulty in combustion optimization of small DI engines, due to small combustion chamber volume, large surface to volume ratio, wide engine speed range and so on. Novel ideas in the area of injection system, combustion chamber and induction swirl were tried to solve these problems and their effects are presented here. Our prototype DI engines which adopted some of these ideas has turned out to have better fuel economy by about 15 percent, 2 - 3 dB(A) higher noise level than IDI and almost the same power output performance as IDI. As to exhaust emissions, they have a possibility to conform to '86 California emission standards, in inertia weight classes up to 2625 LBS. The remaining problem areas are noise emission, durability of injection pump and cabin heater performance. These problems must be solved by further innovation, ...
1985-01-01
Energy Technology Data Exchange (ETDEWEB)
Problems with the refractory liners of incinerator combustion chambers have accompanied incinerators from the very beginning. They increased during the past decade, owing to higher combustion temperatures required by law (17. BImSchV), the higher calorific values of the waste to be combusted, and the higher or changed pollutant concentrations in the waste materials. This caused the providers and the materials and the producers of incinerators to develop new refractory products and new design concepts, with a great variety of processes and cost levels. [German] Seit Beginn der Abfallverbrennung, insbesondere aber mit zunehmender Tendenz in den vergangenen 10 Jahren, wird ueber Probleme mit der Feuerfestauskleidung in den Brennkammern von Abfallverbrennungsanlagen geklagt. Als Gruende fuer die zunehmenden Korrosionsprobleme werden die hoeheren gesetzlich geforderten Verbrennungstemperaturen (17. BImSchV), die hoeheren Heizwerte der verbrannten Abfaelle und die ...
2000-07-01
DEFF Research Database (Denmark)
The objectives of this study were to characterize the changes of VOC material emission profiles over time and develop a method to account for such changes in order to enhance a source identification technique that is based on the measurements of mixed air samples and the emission signatures of individual building materials determined by PTRMS. Source models, including powerlaw model, doubleexponential decay model and mechanistic diffusion model, were employed to track the change of individual material emission signatures by PTRMS over a ninemonth period. Samples of nine typical building materials were tested individually for nine months and later in combination to obtain actual mixture emissions. VOC emissions from each material were measured in a 50liter smallscale chamber. Chamber air was sampled by PTRMS over a 28day period to determine their emission rate decay characteristics as well as to establish the initial profile of emission ...
2011-01-01
Cheng cycle cogeneration system; Cheng cycle system cogeneration setsubi
Energy Technology Data Exchange (ETDEWEB)
This paper presents the Cheng cycle system featured by variable heating/generation ratio for effective operation of cogeneration systems (CGS). In this system, a superheater and reheating burner are added to an exhaust heat recovery (EHR) boiler for conventional gas turbine CGSs, while additional injection steam piping is attached to a gas turbine. Steam is injected through manifolds mounted on the periphery of a combustion chamber, and hot gas mixture of steam and air in a combustion chamber is expanded in a turbine and converted to motive power. This technology thus can improve efficiency and output power, and can operate variably CGSs corresponding to heating and generation demands. This technology has been promoted by introducing the technology of middle class Cheng cycle CGS with 4MW class gas turbine from IPT Co., U.S.A. The first system of 6400 kW is now under production for start of operation in 1996. Its EHR boiler is featured by ...
1996-03-29
Apparatus for producing blast furnace coal
A method of producing blast furnace coke from bituminous coals, particularly coals having poor coking capacities in which the coal to be carbonized is ground, predried or preheated, mixed with binders, compressed or formed into briquets having small mechanical resistances and charged into oven chambers, is characterized by fine coals or fine coal mixtures having a swelling index in mixture according to DIN 51741, smaller than 7, and preferably, below 6, and comprising more than 50% of poorly or non-baking coal having a content of volatile matter in excess of 30% or less than 20% which coals or coal mixtures are ground up to attain a surface per unit mass, according to DIN 66145, of from 400 cm/sup 2/ to 1200 cm/sup 2/ per gram, with from 3% to 8% by weight of organic binders, compressing the mixture to form it into a briquet at a temperature range of from 70/sup 0/C to 300/sup 0/C and charging the compressed briquet into the oven chambers ...
1979-06-19
Air conditioner for radioactive material handling facility
Energy Technology Data Exchange (ETDEWEB)
An air conditioner intakes open-air from an open-air intake port to remove sands and sea salt particles by air filters. Then, natural and artificial radioactive particles of less than 1 {mu}m are removed by high performance particulate filters. After controlling the temperature by an air heater or an air cooler, air is sent to each of chambers in a facility under pressure elevation by a blower. In this case, glass fibers are used as the filter material for the high performance particulate filter, which has a performance of more than 99.97% for the particles of 0.3 {mu}m grain size. Since this can sufficiently remove the natural radioactive materials intruded from the outside, a detection limit value in each of the chambers of the facility can be set 10{sup -13} to 10{sup -14} {mu}ci/cm{sup 3} in respect of radiation control. Accordingly, radiation control can be conducted smoothly and appropriately. (I.N.).
1991-04-26
Energy Technology Data Exchange (ETDEWEB)
Sodium-dependent high-affinity choline uptake was measured in the striatum, frontal cortex, hippocampus, and hypothalamus of rats after acute exposure (45 min) to pulsed (2 microseconds, 500 pps) or continuous-wave 2,450-MHz microwaves in cylindrical waveguides or miniature anechoic chambers. In all exposure conditions, the average whole-body specific absorption rate was at 0.6 W/kg. Decrease in choline uptake was observed in the frontal cortex after microwave exposure in all of the above irradiation conditions. Regardless of the exposure system used, hippocampal choline uptake was decreased after exposure to pulsed but not continuous-wave microwaves. Striatal choline uptake was decreased after exposure to either pulsed or continuous-wave microwaves in the miniature anechoic chamber. No significant change in hypothalamic choline uptake was observed under any of the exposure conditions studied. We conclude that depending on the parameters of the ...
1988-01-01
AMTEC thermo-electric conversion. Final report; AMTEC termo-elektrisk konvertering. Slutrapport
Energy Technology Data Exchange (ETDEWEB)
The aim was to gain experience on how to produce Alkali Metal Thermo-Electric-Converter (AMTEC) cells, for the demonstration of their principles and potentials, as a basis for future commercialization. These cells should be able to present an efficient and direct conversion of thermal energy to electric energy. The system is based on an electro-chemical concentration cell built around a {beta}`` aluminium oxide membrane that separates the two chambers. This material is a good conductor of sodium and a bad conductor of electrons, and it is this property which is taken advantage of. In the two chambers of the cell is found saturated sodium vapour at two temperatures. The motive power is the expansion over the membrane where the sodium ions are transported through it whilst the electrons are forced through the outer cycle. This concept is described in detail in addition to the choice of materials, performance testing and results. It was found ...
1994-10-15
A preliminary stage configuration for a low pressure nuclear thermal rocket (LPNTR)
Energy Technology Data Exchange (ETDEWEB)
A low pressure nuclear thermal rocket (LPNTR) is configured to meet the requirements of a nuclear stage for manned Mars exploration. Safety, reliability and performance are given equal consideration in selecting the stage configuration. Preliminary trade studies are conducted to size the engine thrust and determine the thrust chamber pressure. A weight breakdown and mechanical configuration for the selected LPNTR concept are defined. A seven engine stage configuration is selected which gives a two engine out capability and eliminates the need for engine gimbaling. The stage can be ground assembled and launched as a unit including tankage for trans Earth injection and Earth orbital capture. The tankage is configured to eliminate the need for an inert shield. The small engine will be cheaper to develop than a single engine providing full thrust, and will be compatible with stages for Earth orbital, Lunar and deep space missions. Mission analyses are presented with ...
1990-01-01
Environmental Research Database
DescriptionChamber studies have shown that biogenic organic compounds, including isoprene, are capable of producing secondary organic aerosol in significant quantities. This is surprising as isoprene and its photo-oxidation products have relatively high vapour pressures. However, it is very important as isoprene has the largest global emissions flux of any biogenic hydrocarbon, most of which is in the tropics. Despite this, secondary organic aerosol has been poorly studied in tropical regions with only [continued...
The ArgoNeuT LAr-TPC: A dedicated experiment for neutrino cross section measurement at FNAL
British Library Electronic Table of Contents (United Kingdom)
ArgoNeuT, a Liquid Argon Time Projection Chamber (LAr-TPC), has recently collected thousands of neutrino and anti-neutrino events between 0.1 and 10 GeV in the NuMI beamline at Fermilab (FNAL). Among other issues, the experiment will measure the cross section of the neutrino and anti-neutrino Charged Current Quasi-Elastic (CCQE) interaction on Ar target and analyze the vertex activity associated with such events. Outcomes from the reconstruction of the events provide the main subject of this paper.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
In the year 1996 the spheres of competence of several DLR-Institutes working in the areas of fluid dynamics, reaction kinetics, combustion, numerical methods and laser measuring techniques have been brought together while contributing to the internal DLR project 'combustion chamber modelling (BKM)', in order to proceed with the computational simulation of combustion processes in combustion chambers of gas turbines. The main issue was the development of a research code for numerical simulation of fluid flow in real combustion chambers. Here the development of computational models of physical and chemical processes was emphasized, among other processes the formation of soot was treated. Moreover, a worldwide outstanding database of measured data for the purpose of code validation has been created within the framework of the BKM project using the laboratory facilities of the DLR, which are in Germany unique ...
2002-07-01
Radon measurements in dwellings using activated charcoal
Energy Technology Data Exchange (ETDEWEB)
In Sweden there is a demand for a method of measuring radon in dwellings with high accuracy and at a low cost. A method of determining radon concentration (Bq.m/sup -3/) in dwellings has been developed at the Swedish National Testing Institute. A plastic canister containing activated charcoal has been tested in a radon chamber (volume 20 m/sup 3/) to determine the effects of relative humidity, temperature and exposure time. The activated charcoal in the canister adsorbs radon from the air surrounding the canister. The radon concentration is determined by counting the gamma rays from the decay of radon and daughters. The theory and preliminary results from calibrations and field measurements are reported.
1984-01-01
International Nuclear Information System (INIS)
The textbook is primarily intended for radiologic staff and radiologic safety officers and gives information on the current regulatory provisions of the German X-ray Ordinance, applications of X-rays, quality assurance, organisational aspects of film processing and quality requirements of X-rays. An annex lists the guidelines of the Bundesaerztekammer (German National Chamber of Physicians) relating to quality assurance aspects, and further useful information on commercially available film-screen systems, the various associations of physicians in Germany, and requirements and performance of radiation surveys. (vhe).
Scientific Electronic Library Online (English)
Abstract in english Odontopus brevirostris (Hustache, 1936) feeding on Annona squamosa L., A. cherimola Mill., A. glabra L., and A. muricata L. was observed. The last three host plants are recorded for the first time. The endophitic oviposition occurs in the veins of the ventral surface of the young leaves. The larvae, leaf miners, eat the parenchyma and the adults make small holes in the leaves. The pupation occurs in spherical cocoons protected by a sort of nest (pupation chamber) between the two epidermal layers.
2002-01-01
International Nuclear Information System (INIS)
The global effect of activation cross-section uncertainties on calculated radiological quantities is investigated for the first time using a methodology based on Monte Carlo random sampling. The method is applied to the calculation of the uncertainty in the contact dose rate from the gunite shielding of the National Ignition Facility chamber after 30 yr of pulsed irradiation. Some critical cross section contributing significantly to the overall uncertainty are identified. By a reasonable reduction of the uncertainty in those cross sections, the accuracy in the calculated total contact dose rate is greatly improved.
2003-05-01
Energy Technology Data Exchange (ETDEWEB)
The uranium target of a gas jet transport system for fission products has been modified by the addition of an aluminum cover foil. The new modification allows fission fragments of low mass to enter a continuous chemistry system while heavier fragments are stopped in the aluminum. The elimination of the heavier homologues allows development of simpler and faster chemical separation procedures. In addition, since the lighter fragments are slowed down by the cover foil a smaller target chamber can be used. This leads to a reduction in system holdup time.
1987-04-15
International Nuclear Information System (INIS)
The uranium target of a gas jet transport system for fission products has been modified by the addition of an aluminum cover foil. The new modification allows fission fragments of low mass to enter a continuous chemistry system while heavier fragments are stopped in the aluminum. The elimination of the heavier homologues allows development of simpler and faster chemical separation procedures. In addition, since the lighter fragments are slowed down by the cover foil a smaller target chamber can be used. This leads to a reduction in system holdup time. (orig.).
International Nuclear Information System (INIS)
The method of syndrome coding for data compression read out from multiwire proportional chambers that has been previously proposed is generalized in case of its application to registration of the coordinates of events detected. The questions of execution of arithmetic and algebraic operations on the Galois field elements and their hardware implementation are considered. The method of computation is presented of a specialized processor for parallel computing the coordinates of three sparks. The estimate of its speed is equal to 185 ns. Data compression, data selection and coordinate calculations are performed without use of memory elements and timing pulses.
Method and apparatus for operation of a dual fuel compression ignition combustion engine
Energy Technology Data Exchange (ETDEWEB)
A dual fuel engine control system for controlling the power output of a dual fuel compression ignition engine. The engine includes mixing means for combining an oxidizer and a primary fuel at a substantially constant ratio of oxidizer to primary fuel. The power output of the engine is controlled through the use of a throttle valve controlling the quantity of combustible mixture delivered to the combustion chamber. The fuel control system minimizes the quantity of ignition fuel required by controlling the quantity of combustible mixture rather than the fuel of air ratio. (author) figs.
1994-03-03
Isolated laevocardia and corrected transposition of the great vessels with total situs inversus
International Nuclear Information System (INIS)
Isolated laevocardia combined with corrected transposition of the great arteries and complete situs inversus is rare. Due to discordant interrelationships between atria and ventricles and between ventricles and great arteries, both anomalies result in a normal circulation. In the presented case no associated cardiac malformations were present and the 55-year-old woman remained symptom-free for a long time until she developed an acquired valve disease. A systematic approach to chamber localisation in complex morphologic lesions of the heart is reviewed, and the value of CT, which can be applied successfully in older children and adults is demonstrated. (orig.).
Energy Technology Data Exchange (ETDEWEB)
In order to promote the use of natural gas air-conditioning systems in the tertiary sector, Gaz de France (the French gas utility) in association with Electricite de France (EdF) and the French chamber of council engineers (CICF) have created the Acerclim organization which aims at certifying the quality of the design, realization and exploitation of air processing and air-conditioning installations according to the ISO 9001 criteria. This article describes this quality procedure named 'CHSB Air'. (J.S.)
2002-07-01
Improvement of assessment methodology for fluid flow characteristics of passive flow control device
International Nuclear Information System (INIS)
The objective of this study is to establish evaluation and verification guideline for the APR 1400 and to investigate the thermal-hydraulic characteristics for fluidic device is analyzed using FLUENT. The scope and major results of research are flow characteristics for fluidic device. In this study, three-dimensional numerical model for fluidic device is developed adequately for, and results are compared with experimental data performed by VAPER (VAlve Performance Evaluation test Rig) in KAERI with an aim to verify numerical simulation. In addition, the parametric study has also carried out to investigate the effect of major parameters such as velocity and pressure inside FD chamber.
2002-10-01
Hot-air turbine plant at Voelklingen model power plant
Energy Technology Data Exchange (ETDEWEB)
The integration of a gas turbine into a new type of coal-fired combined cycle power plant necessitates a multiplicity of far-reaching changes compared with a normal design. The extremely high pre-heating temperature of the air emanating from the heat exchanger of the fluidized bed for the gas turbine combustion chamber has necessitated extensive development work and associated combustion trials. It was possible for these results to influence the design of the burners whereas the manufacture of other components which was on the critical path was already far advanced.
1984-06-01
International Nuclear Information System (INIS)
The authors describe measurements of emittance made on samples of solar cell coverglasses incorporating new coatings both on C-7940 fused silica and on CMX ceria doped microsheet. Samples of a conventional, MgF_2 coating on the same two types of coverglass substrates were included in the measurements as controls. Measurements were made by the calorimetric method of total hemispherical emittance within a cooled chamber as well as by the more common infrared reflectance method. Emittance enhancements from 1 to 4% were measured for the new coatings.
1988-09-26
Dispersion Interferometer Based on CO2 Laser
International Nuclear Information System (INIS)
A dispersion interferometer based on CO2 laser for measurements of plasma line density in the gas dynamic trap (GDT) experiment has been developed with sensitivity el>min ? 1.1013 cm-2, temporal resolution ?50 ns. The main advantages of the interferometer are compactness and low sensitivity to vibrations. The interferometer does not require specific vibration isolation structure and can be mounted directly on the working chamber of the plasma device. The above mentioned advantages have been successfully demonstrated in the Gas Dynamic Trap experiments.
2005-01-01
Determining top dead center in fired internal combustion engines by microwaves
Energy Technology Data Exchange (ETDEWEB)
For the determination of top dead center (TDC) of a running engine a measuring system using microwaves was developed by AEG and Volkswagen AG. The measuring method utilizes the Doppler shift of the microwaves, which were reflected at the up and down moving piston, and the varying resonance properties of the combustion chamber. The system works with a frequency of 61.4 GHz and can be used as well for spark ignition as form compression ignition engines, particularly for direct injection engines. The output signal is symmetrical to TDC. For data acquisition and data processing, i.e. the calculation of the point of symmetry, the computer system FARES is used in a special assembly.
1986-01-01
Detailed kinetic modeling of autoignition chemistry
Energy Technology Data Exchange (ETDEWEB)
The development of detailed chemical kinetic reaction mechanisms for analysis of autoignition and knocking of hydrocarbon fuels is described. In particular, kinetic processes of concern for the oxidation of complex hydrocarbon fuel molecules are emphasized. The wide ranges of temperature and pressure which are encountered by end gases in automobile engine combustion chambers result in extreme demands on reaction mechanisms which are intended to describe knocking conditions and predict rates of combustion and ignition. The reactions and chemical species which are most important in each temperature and pressure regime are discussed, and the validation of these reaction mechanisms through comparison with idealized experimental results is described. 53 refs., 8 figs., 5 tabs.
1987-07-22
Energy Technology Data Exchange (ETDEWEB)
This is the final report covering work performed on research into methods of attaining clean ferrous castings. In this program methods were developed to minimize the formation of inclusions in steel castings by using a variety of techniques which decreased the tendency for inclusions to form during melting, casting and solidification. In a second project, a reaction chamber was built to remove inclusions from molten steel using electromagnetic force. Finally, a thorough investigation of the causes of sand penetration defects in iron castings was completed, and a program developed which predicts the probability of penetration formation and indicates methods for avoiding it.
1996-01-31
A study of aging effects in gas proportional detectors at the BAC calorimeter of the ZEUS experiment
Energy Technology Data Exchange (ETDEWEB)
The multicell proportional chambers at the backing calorimeter of the ZEUS experiment at the storage ring HERA are supplied with a gas mixture of Ar/CO[sub 2] by an open gas system. Flow proportional counters with the build-up [sup 55]Fe sources are used as gas system monitoring detectors. The ZEUS experiment is planned to collect data for about 10 years. Therefore, the lifetime of the Ar/CO[sub 2] mixture should be known. In this paper, the results of laboratory tests and preliminary measurements of the aging effects for monitoring counters are presented. ((orig.))
1994-09-01
A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection
Energy Technology Data Exchange (ETDEWEB)
A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).
1991-05-01
A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection
International Nuclear Information System (INIS)
A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).
Small scale wood chip fuel harvesting and processing
Energy Technology Data Exchange (ETDEWEB)
The objectives of the project were to demonstrate and evaluate several small-scale methods of harvesting small (200 mm or less) trees and chipping them for fuel, as well as a method of processing such chips for use in dry chip-fired heating appliances. Nine field trials were conducted using various combinations of equipment. The trials consisted of 2 slash reclamation tests, 2 thinning tests, and 5 clear-cutting tests. The tests were conducted on various sites ranging from 0.2 to 1.8 hectares in area. The trees harvested were small; their average stem diameter was 70 mm. Every site was measured before harvest to predict the amount of biomass present. The amount of material obtained from the sites varied from 50% to 80% of the biomass present. Harvesting consisted of chain-saw felling and delimbing, skidding to roadside using winch, and then chipping into a 30 m{sup 3} portable bin. At the processing facility, the chips were weighed and dumped, reclaimed, metered, screened and delivered ...
1985-02-01
Energy Technology Data Exchange (ETDEWEB)
Late plagiogranite bodies in the Semail ophiolite have been previously suggested to represent late stage fractionates within an episodic spreading center magma chamber or the roots of seamount chains. Field and lab observations suggest that these late silicic magma chambers represent zones of repeated injection by dikes of intermediate to mafic composition. Multiple generations of intrusion, partial resorption and reintrusion are preserved in the plagiogranite as 1) relict phantom xenoliths, 2) angular xenoliths with quartz-rich margins, 3) deformed fine-grained dikes with distinct chilled margins, and 4) planes of rectangular blocks with cuspate margins or ellipsoids of similar fine grained mafic materials. The blocks and ellipsoids are actually dismembered mafic dikes that chilled by intruding a cooler silicic liquid and were either thermally fractured or pinched out. All of the dikes are hydrothermally altered to assemblages including amph., ...
1985-01-01
Energy Technology Data Exchange (ETDEWEB)
ABSTRACT-Here we identify release of annexin A2 into the culture medium in response to low dose X-ray radiation exposure and establish functional linkages to an established paracrine factor-mediated anchorage-independent growth response. Using a standard bicameral coculture model, we observe that annexin A2 levels associated with non-irradiated neighboring cells seeded in the lower chamber (annexin A2 silenced [shRNA] JB6 cells) are increased upon coculture with irradiated (10-50 cGy) JB6 cells seeded in the upper chamber, relative to coculture with sham exposed JB6 cells seeded in the upper chamber, suggesting that annexin A2 released into the medium is capable of communicating in a paracrine fashion. Using a previously established coculture model, we observed that the paracrine factor-mediated anchorage-independent growth response to low dose X-ray radiation is markedly reduced when irradiated annexin A2 silenced (shRNA) ...
2009-07-13
Energy Technology Data Exchange (ETDEWEB)
A high power (200KV), intense current density, low emittance (71mmmrad), high brightness (8x10{sup 10}A/m rad) electron beam was generated in the 10cm long, high-voltage-resistive multi-gap hollow cathode pseudospark chamber filled with 15pa nitrogen and driven by an improved pulse line accelerator. The beam was ejected with the 1mm diameter, the 2.2KA beam current, and the 400ns pulse length, and could propagated 20cm in the drift tube. At a distance of 5cm from the anode it penetrated consecutively an acid-sensitive discoloring film and a 0.05mm-thick copper foil both stuck closely, left 0.6mm and 0.3mm holes on them, respectively. That 10 shots on an acid-sensitive film produced a hole of 1.6mm at 7cm downstream of anode showed its good repeatability. After 60 shots the pseudospark discharge chamber was disassembled and observed that almost no destructive damage traces left on the surfaces of its various electrodes and insulators. But on ...
1995-12-31
Analysis of log rate noise in Ontario's CANDU reactors
Energy Technology Data Exchange (ETDEWEB)
In the fall of 2003, the operators noticed that in the recently-refurbished Bruce A Shutdown System no. 1 (SDS1) the noise level in Log Rate signals were much larger than before. At the request of the Canadian Nuclear Safety Commission (CNSC), all Canadian CANDU reactors took action to characterize their Log Rate noise. Staff of the Inspection and Maintenance Services division of Ontario Power Generation (OPG) has collected high-speed high-accuracy noise data from nearly all 16 Ontario reactors, either as part of routine measurements before planned outages or as a dedicated noise recording. This paper gives the results of examining a suitable subset of this data, with respect to the characteristics and possible causes of Log Rate noise. The reactor and instrumentation design is different at each station: the locations of the moderator injection nozzles, the location of the ion chambers for each system, and the design of the Log Rate amplifiers. It was found that ...
2007-07-01
VUV efficiency and radiant emittance characterization of xenon positive column discharges
Energy Technology Data Exchange (ETDEWEB)
The pure xenon dc positive column discharge has been characterized for various xenon pressures, currents, and discharge tube radii. The absolute output at the 147 nm resonance transition has been measured using two independent techniques to yield the radiant emittance at 147 nm (power per unit surface area). The efficiency of 147 nm production is obtained by combining the measured radiant emittance with the measured electrical power per unit length deposited in the gas. The radiant emittance and the efficiency are the two principle figures of merit for characterizing the discharge as a source of VUV radiation. It is observed that the trends in efficiency and radiant emittance change substantially when the discharge transitions from two-step electron impact excitation/ionization at higher pressures to single-step electron impact ionization at lower pressures. Modeling of the xenon positive column discharge yields radiant emittance and efficiency ...
1996-12-31
Unification of Luminous Type 1 Quasars through CIV Emission
Using a sample of 30,000 quasars from SDSS-DR7, we explore the range of properties exhibited by high-ionization, broad emission lines, such as CIV 1549. Specifically we investigate the anti-correlation between L_UV and emission line EQW (the Baldwin Effect) and the "blueshifting" of high-ionization emission lines. The blueshift of the CIV emission line is nearly ubiquitous, with a mean shift of 810 km/s for radio-quiet (RQ) quasars and 360 km/s for radio-loud (RL) quasars, and the Baldwin Effect is present in both RQ and RL samples. Composite spectra are constructed as a function of CIV emission line properties in attempt to reveal empirical relationships between different line species and the SED. Within a two-component disk+wind model of the broad emission line region (BELR), where the wind filters the continuum seen by the disk component, we find that RL quasars are consistent with being dominated by the disk component, while BALQSOs are ...
2010-01-01
The Development of a Neutral Particle Detector for Observations of the Thermosphere
One of the least understood regions of the upper atmosphere is the thermosphere, principally due to the difficulty of making observations. The neutral atmosphere is known to be highly variable, and its composition and density varies by several orders of magnitude due to solar activity, diurnal cycles, latitude, geomagnetic activity, and gravity waves. In the past, most in-situ measurements of the neutral atmosphere have utilized detectors that are dependent on arrival angle and energy accommodation of incoming species, so that information related to nascent velocity distribution and reactive species abundances is often masked. This paper will review design concepts and laboratory tests related to the development of a novel open-ionizer, neutral particle detector for space environment measurements which can overcome these limitations. The sensor features a very large field-of-view suitable for sounding rocket missions. This time-of-flight instrument uses ...
2006-12-01
Energy Technology Data Exchange (ETDEWEB)
Food irradiation is the processing of food products by ionizing radiation in order, among other things, to control food borne pathogens, reduce microbial load and insect infestation, inhibit the germination of root crops, and extend the durable life of perishable products. Irradiation of dried food ingredients, particularly herbs and spices, has a great application potential, and has already been implemented in many countries. Spice irradiation is performed to increase the hygienic quality and used as decontamination processes instead of fumigation methods. European Community approves irradiation processing as an effective residue-free alternative. The present paper evaluates the effect of ionizing radiation on sensorial properties of cinnamon (Laurus cinnamomum) and nut meg (Myristica fragans). The samples have been irradiated in multipurpose irradiator of {sup 60}Co in the doses: 0, 5, 10, 15, 20 e 25 kGy. (author)
2007-07-01
Predicted UV properties of very metal-poor starburst
We study the expected properties of starbursts in order to provide the point of reference for interpretation of high-z galaxy surveys and of very metal-poor galaxies. We concentrate mainly on the UV characteristics such as the ionizing spectra, the UV continuum, the Ly alpha and HeII 1640 A line and two-photon continuum emission. We use evolutionary synthesis models covering metallicities from Pop III to solar and a wide range of IMFs. We also combine the synthetic SEDs with the CLOUDY photoionization code for more accurate predictions of nebular emission, and to study possible departures from case B assumed in the synthesis models. The ionizing fluxes, UV continuum properties, and predicted Ly alpha and HeII 1640 A line strengths are presented for synthesis models covering a wider range of parameter space than our earlier calculations. Strong departures from case B predictions are obtained for Ly alpha and two-photon continuum at low ...
2010-01-01
International Nuclear Information System (INIS)
In this paper, results on ozone production by atmospheric pulsed discharge, are reported. In the research, two types of ozonizer (Type I and Type II) have been used to investigate improvements of ozone concentration and production efficiency. The ozonizer has plane-to-plane metal electrodes structure, and pre-ionization electrodes are placed on the high voltage electrodes (Type I). In Type II, the surface of grounded electrode with 20 mm of width is covered partly by dielectric (thin rubber) with 11 mm of width, while the geometry of both metal electrodes is same to Type I. In the case of Type I, maximum concentration of about 100 ppm and maximum yield of 70 g/kWh were obtained at input power of 0.3 W. On the other hands, in the case of Type II, 800 ppm and 100 g/kWh were obtained at input power of 1.5 W. It was found that the ozone concentration and production yield were improved by using electrode covered by dielectric. (author)
2002-07-21
Multipass laser mass spectrometer with extreme jet-cooled pulsed gas
International Nuclear Information System (INIS)
We have developed a photon accumulated laser mass spectrometer that enables us to identify isomers of polychlorinated dibenzo-p-dioxin and polychlorinated dibenzofuran. This system is comprised of a high temperature (230 deg. C) pulsed gas injector (PGI), multimirror multipath system (MMS), and the conventional time-of-flight mass spectrometer. The PGI induces the formation of a choked supersonic jet gas pulse that cools down to a temperature to restrain fragmentation and reduces vibrational and rotational thermal noises. The results suggest that the excited lifetime numbers and fragment dynamics of these species change completely with jet cooling of molecules. The MMS enhances the soft ionization efficiency (by a factor of 1000 over a single path system) through photon accumulation by extending the irradiation duration (to about 40 ns) and volume, and it further minimizes fragmentation by carefully controlling the laser intensity distribution within the ...
2006-09-01
Isotope shift measurements at the {sup 242{ital f}}Am fission isomer
Energy Technology Data Exchange (ETDEWEB)
Isotope shift measurements have been performed for the {sup 242{ital f}}Am fission isomer with target production rates of only a few per second. The method is based on resonance ionization spectroscopy (RIS) in a buffer gas cell with radioactive decay detection of the ionization process (RADRIS). A relative isotope shift ratio X{sub {ital exp}}=IS{sup 242{ital f},241}/IS{sup 243,241}=41.7{plus_minus}0.9 has been measured for the 500.02 nm transition corresponding to a nuclear parameter A{sup 242{ital f},241}=(5.4{plus_minus}0.3) fm{sup 2}. A preliminary analysis of the quadrupole moment based on the deformed Fermi model of the nuclear charge distribution results in Q{sub 20}=35.9{plus_minus}1.1({sup +0.3}{sub {minus}0.7}) {sub model} eb. {copyright} 1995 {ital American} {ital Institute} {ital of} {ital Physics}
1995-04-01
Ion sources for initial use at the Holifield radioactive ion beam facility
Energy Technology Data Exchange (ETDEWEB)
The Holifield Radioactive Ion Beam Facility (HRIBF) now under construction at the Oak Ridge National Laboratory will use the 25-MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility; the choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. A high-temperature version of the CERN-ISOLDE positive ion source has been selected and a modified version of the source designed and fabricated for initial use at the HRIBF because of its low emittance, relatively high ionization efficiencies and species versatility, and because it has been engineered for remote ...
1994-12-31
Ion sources for initial use at the Holifield Radioactive Ion Beam Facility
Energy Technology Data Exchange (ETDEWEB)
The Holifield Radioactive Ion Beam Facility (HRIBF) now under construction at the Oak Ridge National Laboratory will use the 25-MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility; the choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. A high-temperature version of the CERN-ISOLDE positive ion source has been selected and a modified version of the source designed and fabricated for initial use at the HRIBF because of its low emittance, relatively high ionization efficiencies and species versatility, and because it has been engineered for remote ...
1994-05-01
Energy Technology Data Exchange (ETDEWEB)
The interference of hyperthermia and ionizing radiation, respectively, with the effects of capric (10:0), lauric (12:0), myristic (14:0), oleic (cis-18:1) and elaidic (trans-18:1) acids on the osmotic resistance of human erythrocytes was investigated. The results are summarized as follows: (A) not only at 37 degrees, but also at 42 and 47{degrees}C lauric acid (12:0) represents the minimum chain length for the biphasic behaviour of protecting against hypotonic hemolysis at a certain lower concentration range and hemolysis promotion at subsequent higher concentrations; (B) with increasing temperatures the protecting as well as the hemolytic effects occur at lower concentrations of the fatty acids; (C) the increase of temperature promotes the extent of hemolysis and reduces the extent of protection against hypotonic hemolysis; (D) Gamma-irradiation of erythrocytes selectively affects the concentration of oleic acid at which maximum protection against hypotonic ...
1990-04-01
Integral Field Unit Observations of NGC 4302: Kinematics of the Diffuse Ionized Gas Halo
We present moderate resolution spectroscopy of extraplanar diffuse ionized gas (EDIG) emission in the edge-on spiral galaxy NGC 4302. The spectra were obtained with the SparsePak integral field unit (IFU) at the WIYN Observatory. The spectra are used to construct position-velocity (PV) diagrams at several ranges of heights above the midplane. Azimuthal velocities are directly extracted from the PV diagrams using the envelope tracing method, and indicate an extremely steep dropoff in rotational velocity with increasing height, with magnitude ~30 km/s/kpc. We find evidence for a radial variation in the velocity gradient on the receding side. We have also performed artificial observations of galaxy models in an attempt to match the PV diagrams. The results of a statistical analysis also favor a gradient of ~30 km/s/kpc. We compare these results with an entirely ballistic model of disk-halo flow, and find a strong dichotomy between the observed kinematics and those ...
2007-01-01
International Nuclear Information System (INIS)
The inelastic energy losses for single collisions of Xe"+ ions with Xe targets have been measured for incident ion energies from 0.3 to 1.2 MeV and for scattering angles from 3"0 to 20"0. The energy losses were found to range from 1 to 11 keV with distinct steps at distances of closest approach of 0.22 and 0.12 A. By comparing these data with earlier ionization data by the same authors these steps are shown to be caused by M-shell excitation. Other excitations observed in the ionization data may be attributed to N-shell excitation. The distances of closest approach at which these excitations occur agree well with calculations by Eichler and Wille and co-workers, giving further evidence of the usefulness of Fano and Lichten's one-electron molecular model and these calculations.
IR double-resonance spectroscopy applied to the 4-aminophenol(H{sub 2}O){sub 1} cluster
Energy Technology Data Exchange (ETDEWEB)
The IR double-resonance techniques IR/R2PI (infrared/resonant 2-photon ionization), IR/PIRI (infrared-photo-induced Rydberg ionization) and IR-photodissociation spectroscopy are valuable tools to investigate structure, vibrations, and dynamical processes of neutral and ionic hydrogen-bonded clusters containing aromatic molecules. In this paper we report on the application of the IR double-resonance techniques to determine the NH and OH stretching vibrations of 4-aminophenol and 4-aminophenol(H{sub 2}O){sub 1}, both in the neutral (S{sub 0}) and ionic (D{sub 0}) ground state. All vibrational frequencies obtained for 4-aminophenol and the cluster are compared with the values obtained from ab initio and DFT calculations. In the S{sub 0} state, a trans-linear arrangement of 4-aminophenol(H{sub 2}O){sub 1} is obtained containing an O-H. O hydrogen bond. In the D{sub 0} state an overlay of two spectra can be observed resulting from the trans-linear ...
2001-03-01
Hyaluronic acid production by irradiated human synovial fibroblasts
International Nuclear Information System (INIS)
Radioactive particles as well as x irradiation from an external source has been used in the treatment of rheumatoid arthritis, osteoarthritis, and ankylosing spondylitis. In order to clarify effects of ionizing irradiation on synovial cells, radioactive gold ("1"9"8Au) and yttrium ("9"0Y) were added to fibroblast cultures derived from human synovial membranes. Other cultures were irradiated by a Picker x-ray machine. Fibroblast growth and hyaluronic acid production were measured. Radioactive gold and yttrium particles induced a significant increase of hyaluronic acid synthesis rate (pg/cell/day) and inhibited fibroblast growth. Fibroblasts continued to overproduce hyaluronic acid and to show growth inhibition 3 weeks after irradiation with radioactive gold. Hydrocortisone inhibited hyaluronic acid overproduction induced by radioactive gold. Overproduction of hyaluronic acid induced by the x-ray machine was inhibited by hydrocortisone, actinomycin-D, and ...
1977-01-01
International Nuclear Information System (INIS)
The genetically significant dose (GSD) is an index variable which exclusively allows to describe the genetic risk in the progeny of a population due to the application of ionizing radiation and radioactive substances in one part of this population. It may result in wrong interpretation of population exposure at increasing incidence of examinations in a population involving ionizing radiation and radioactive drugs at simultaneously increasing application of alternative methods in children and adolescents owing to the fact that it indicates a downward trend although somatic exposure of this population has increased. Therefore, it is recommended to state both the GSD and the level of somatic radiation exposure of the population taken from the individual sources for the comparison and assessment of radiation exposure from various sources in future. Although the somatically significant dose constitutes the suitable variable complementary to GSD in ...
1984-06-01
Deposition of Cu film on SiO_2 using a partially ionized beam
International Nuclear Information System (INIS)
Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO_2 substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio I(111)/I(200) reaches its maximum value indicating a strong left-angle 111 right-angle texture, while the impurity concentration and resisitivity are minimum. The correlation between the structural, compositional and electrical properties are discussed in the ...
1990-01-01
Deposition of Cu film on SiO sub 2 using a partially ionized beam
Energy Technology Data Exchange (ETDEWEB)
Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO{sub 2} substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio {ital I}(111)/{ital I}(200) reaches its maximum value indicating a strong {l angle}111{r angle} texture, while the impurity concentration and resisitivity are minimum. The correlation between the structural, compositional and electrical properties are ...
1990-05-01
Deposition of Cu film on SiO sub 2 using a partially ionized beam
Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO{sub 2} substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio {ital I}(111)/{ital I}(200) reaches its maximum value indicating a strong {l angle}111{r angle} texture, while the impurity concentration and resisitivity are minimum. The correlation between the structural, compositional and electrical properties are ...
1990-05-01
International Nuclear Information System (INIS)
The dependences of kinetic energies and peak profiles of multicharged ions of I "q"+ (q = 2-3) and C"2"+ on the laser intensity have been studied in detail by time-of-flight mass spectrometry, those multicharged ions are produced by irradiation of methyl iodide cluster beam with a nanosecond 532 nm Nd-YAG laser. Our experiments show that the kinetic energies released of multicharged ions increase linearly with the laser intensity in the range of 3 x 10"9-2 x 10"1"1 W/cm"2. The peaks of multicharged ions are split to forward ions and backward ions, and the ratio of the backward ions to forward ions decreases exponentially with laser intensity. The decreasing of backward ions is probably due to Coulomb scattering by the heavier I"+ ions when they turn around through the laser focus point. The linear dependence of kinetic energy of multicharged ions on laser intensity is interpreted by the ionization mechanism, in which the laser induced inverse bremsstrahlung heating ...
2006-03-20
Can photo-ionization explain the decreasing fraction of X-ray obscured AGN with luminosity?
Chandra and XMM surveys show that the fraction of obscured AGN decreases rapidly with increasing luminosity. Although this is usually explained by assuming that the covering factor of the central engine is much smaller at luminous QSOs, the exact origin of this effect remains unknown. We perform toy simulations to test whether photo-ionisation of the obscuring screen in the presence of a strong radiation field can reproduce this effect. In particular, we create X-ray spectral simulations using a warm absorber model assuming a range of input column densities and ionization parameters. We fit instead the simulated spectra with a simple cold absorption power-law model that is the standard practice in X-ray surveys. We find that the fraction of absorbed AGN should fall with luminosity as $L^{-0.16\\pm0.03}$ in rough agreement with the observations. Furthermore, this apparent decrease in the obscuring material is consistent with the dependence of the FeK$\\alpha$ ...
2008-01-01
Animal models of ionizing-radiation damage. Technical report, 18 May 88-18 May 91
Energy Technology Data Exchange (ETDEWEB)
This report is a survey of the English language literature of radiation biology between 1947 and 1987, for the purpose of compiling a literature base on the effects of radiation on animals, which have yielded results that can expand our knowledge about similar radiation effects on human beings. Articles were sought that reported exposure of adult mammals to external sources of ionizing radiation, having endpoints that included effects on the brain, the spinal cord, and behavior of the gastrointestinal, endocrine, and cardiovascular systems and the hematopoietic and immune systems. Effects of interest were those that occurred within the first 12 months after exposure. The survey does not include articles reporting chronic or long term delayed effects of radiation unless they provided insight into mechanisms of morphological and/or functional derangement. Information presented in the report is divided into subtopics (i.e., Brain-Morphological Changes). The brief ...
1992-01-01
British Library Electronic Table of Contents (United Kingdom)
A comprehensive and highly selective method for detecting in bacterial supernatants a modified sulfur nucleoside, S-adenosyl-L-methionine (SAM), and its metabolites, i.e., S-adenosylhomocysteine (SAH), adenosine (Ado), 5prime-deoxy-5prime-methylthioadenosine (MTA), adenine (Ade), S-adenosyl-methioninamine (dcSAM), homocysteine (Hcy) and methionine (Met), was developed. The method is based on reversed-phase liquid chromatography with positive electrospray ionization (ESI+) coupled to a hybrid linear quadrupole ion trap (LTQ) and 7-T Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS). A gradient elution was employed with a binary solvent of 0.05 M ammonium formate at pH 4 and acetonitrile. The assay involves a simultaneous cleanup of cell-free bacterial broths by solid-pha...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
This report describes the work performed during FY 1995 by Pacific Northwest Laboratory in developing and optimizing analysis techniques for identifying organics present in Hanford waste tanks. The main focus was to provide a means for rapidly obtaining the most useful information concerning the organics present in tank waste, with minimal sample handling and with minimal waste generation. One major focus has been to optimize analytical methods for organic speciation. Select methods, such as atmospheric pressure chemical ionization mass spectrometry and matrix-assisted laser desorption/ionization mass spectrometry, were developed to increase the speciation capabilities, while minimizing sample handling. A capillary electrophoresis method was developed to improve separation capabilities while minimizing additional waste generation. In addition, considerable emphasis has been placed on developing a rapid screening tool, based on Raman and ...
1995-09-01
Additive effects common to radiation grafting and wood plastic composite formation
Energy Technology Data Exchange (ETDEWEB)
A range of additives has been developed for enhancing grafting yields in a variety of systems initiated by ionizing radiation. Cellulose has been adopted as the predominant naturally occurring model backbone polymer in these studies because of its structural relationship to wood which is the reference substrate for the work reported in the related second part of this paper concerning composites. Some experiments have been performed with the other major naturally occurring polymer, wool. For comparison purposes with synthetic materials, some studies have also been performed with polypropylene as trunk polymer. Styrene has been used as a predominant monomer in grafting with some experiments utilizing the acrulates like methyl methacrylate. The role of solvent in grafting has been evaluated. UV has been used as initiator to replace ionizing radiation for certain experiments. The additives used were mineral acids, lithium salts, multifunctional ...
1996-08-01
TIGER integral-field spectrography and HST/WFPC2 imaging of the E3 galaxy NGC 2974 are used to derive the kinematics of the stellar and ionized gas components in its central 500 pc. We derive a numerical two-integral distribution function from a MGE mass model using the HQ formalism. The TIGER as well as published long-slit stellar kinematics are well fitted with this self-consistent model, requiring neither the addition of a significant mass contribution from a hidden disc structure, nor the presence of a central dark mass. The data reveal the presence of a striking, highly contrasted, two-arm gaseous spiral structure within a radius of ~200 pc, corresponding to a total mass of 6.8x10^4 Msun of ionized gas. We use a deconvolved TIGER datacube to probe its kinematics at a resolution of about 0.35 arcsec. Strong departures from circular motions are observed, as well as high velocity dispersion values on the inner side of the arms. We interpret ...
2003-01-01
The General Spectral Modeling (GSM) code employs the quasi-static approximation, a standard, low-density methodology that assumes the ionization balance is separable from a determination of the excited-state populations that give rise to the spectra. GSM also allows for some states to be treated only as contributions to effective rates. While these two approximations are known to be valid at low densities, this work investigates using such methods to model high-density, non-LTE emission spectra and determines at what point the approximations break down by comparing to spectra produced by the LANL code ATOMIC which makes no such approximations. As both approximations are used by other astrophysical and low-density modeling codes, the results should be of broad interest. He-like K$\\alpha$ emission spectra are presented for Ni, Fe, and Ca, in order to gauge the effect of both approximations employed in GSM. This work confirms that at and above the temperature of ...
2007-01-01
Transverse glow discharges in supersonic air and methane flows
British Library Electronic Table of Contents (United Kingdom)
Transverse glow discharges in supersonic air and methane flows are studied both experimentally and theoretically. The experiments show that a diffuse volume discharge filling the whole cross section of the flow can easily be initiated in air, whereas a diffuse discharge in a methane flow shows a tendency to transition into a constricted mode. The electron transport coefficients (mobility and drift velocity) and the kinetic coefficients (such as collisional excitation rates of the vibrational levels of a methane molecule, as well as dissociation and ionization rates) are calculated by numerically solving the Boltzmann equation for the electron energy distribution function. The calculated coefficients are used to estimate the parameters of the plasma and the electric field in the positive co...
2006-01-01
The pharmacological activity of medical herbs after microbiological decontamination by irradiation
Energy Technology Data Exchange (ETDEWEB)
In the Institute of Nuclear Chemistry and Technology research on microbiological decontamination of medicinal herbs by irradiation has been carried out since 1996. It was shown that using ionizing radiation (a dose of 10 kGy) can obtain satisfactory results of microbiological decontamination of these products. The content of essential biologically active substances such as essential oils, flavonoids, glycosides, anthocyans, antra-compounds, poliphenoloacids, triterpene saponins, oleanosides and plants mucus did not change significantly after irradiation. Pharmacological activity of medicinal herbs has been found satisfactory after microbiological decontamination by irradiation.
2000-03-01
The advancement of stem cells in radiation medicine
International Nuclear Information System (INIS)
It may result in acute radiation syndrome after body is exposed to ionizing radiation. The one of long-term effects of irradiation injury is leukemia. The bone marrow cells (BMC) transplantation including stem cells is the only effective therapy for acute radiation syndrome patients. Recently, with the advancement of stem cell research that the stem cells have multipotential and can convert each other, it may supply the new stem source for the irradiation injury patients. At the same time with the further research of radioprotective reagents, the hematopoietic stem cells proliferation after irradiation injury is promoted
2003-02-01
Study of somatic radiation effects in environment
International Nuclear Information System (INIS)
A survey is presented of the consequences of the irradiation of the population with ionizing radiation. There is an increased incidence of leukemia in irradiated population groups. Among the inhabitants of Hiroshima and Nagasaki maximum death of leukemia was observed in the years 1951 to 1952. The results are summed up of the observation of carcinoma of the breast, lungs and bronchi, bones, and carcinoma of the thyroid. The effect of radiation on experimental animals is described. It was found that the scatter of the dependence of the incidence of various types of cancer on the dose equivalent apparently reflects differences in the biological mechanism of this incidence and that a proportional relationship cannot be expected between the primary damage of cells during irradiation and the actual manifestation of the disease. (E.S.).
Robotics and Automation Activities at the Savannah River Site: A Site Report for SUBWOG 39F
Energy Technology Data Exchange (ETDEWEB)
The Savannah River Site has successfully used robots, teleoperators, and remote video to reduce exposure to ionizing radiation, improve worker safety, and improve the quality of operations. Previous reports have described the use of mobile teleoperators in coping with a high level liquid waste spill, the removal of highly contaminated equipment, and the inspection of nuclear reactor vessels. This report will cover recent applications at the Savannah River, as well as systems which SRS has delivered to other DOE site customers.
1995-09-28
Results of a search for monopoles and tachyons in horizontal cosmic ray flux
International Nuclear Information System (INIS)
A search for monopoles and tachyons at ground level was carried out using an arrangement consisting of an ionization calorimeter and two hodoscope detectors. No clear evidence for these particles was obtained. The flux of monopoles with velocities beta approximately 0.01 is found to be less than 5.1 x 10 to the minus 13th power square centimeters s(-1) sr(-1) (95% cl.). The upper limit on the tachyon flux density is set as a 6 x 10 the minus 9th power particle/square centimeter event.
1985-08-01
Recycling of PTFE by means of ionizing rays
International Nuclear Information System (INIS)
By treatment with beta or gamma rays, PTFE waste is converted to high-grade PTFE fine powder. High-molecular weight PTFE is degraded to low-molecular weight PTFE. Due to this the density, the degree of crystallinity, and the melt flow index are increased, which enhances the brittleness of the material. Irradiation of PTFE thus facilitates milling and makes the material pourable and free-flowing. Milled PTFE fine powder, lie PTFE plastic, combines temperature resistance, weather fastness, and chemical stability with good slip behaviour and antiadhesive properties. Areas of application for fine powder include additives for plastics, printing inks, nonstick coatings, and antifriction lacquers. (orig.).
1994-01-01
Energy Technology Data Exchange (ETDEWEB)
Current information on the use of ionizing radiation for improving the storage of subtropical fruits like citrus, grapes, and avocados is reviewed. The feasibility of applying radiation either alone or in combination with other physical or chemical treatments for the control of postharvest fungal diseases is considered. Irradiation effects on the physiology of the fruits as related to respiration, ethylene evolution, changes in major chemical constituents, and quality are discussed. The recent trends in the possible use of irradiation as an alternative treatment to chemical fumigants for disinfestation of citrus and avocados and the prospects for the future application of irradiation for preservation of some of these fruits are outlined. 128 references.
1986-01-01
Radiation hardening of semiconductor parts
International Nuclear Information System (INIS)
This chapter is an overview of total-ionizing-dose and single-event hardening techniques and should be used as a guide to a range of research publications. It should be stressed that there is no clear and simple route to a radiation-tolerant silicon integrated circuit. What works for one fabrication process may not work for another, and there are many complex interactions within individual processes and designs. The authors have attempted to highlight the most important factors and those process changes which should bring improved hardness. The main point is that radiation-hardening as a procedure must be approached in a methodical fashion and with a good understanding of the response mechanisms involved.
Radiation hardening characterization of a VDMOS developed at CAS institute of microelectronics
International Nuclear Information System (INIS)
Total dose irradiation effects on a VDMOS developed at Institute of Microelectronics, CAS were investigated, particularly the electric parameter changes under different bias conditions. It was found that the breakdown voltage degradation by the irradiation depended mainly on the drain bias, whereas the threshold voltage degradation depended mainly on the gate bias. Thus, an innovative and effective method to domestic VDMOS total dose ionization characterization is that threshold voltage radiation hardening characterization should be tested on gate bias condition, and the breakdown voltage radiation hardening characterization, be tested on the drain bias. (authors)
2008-08-01
International Nuclear Information System (INIS)
The paper discusses some of the assumptions and methods employed for the control of ionizing radiation in the specifications for the civil construction of a planned free electron laser facility based on a 200 MeV, 5 mA superconducting recirculation electron accelerator. Consideration is given firstly to the way in which the underlying building configuration and siting aspects were optimized on the basis of the early assumptions of beam loss and radiation goals. The various design requirements for radiation protection are then considered, and how they were folded into an aesthetically pleasing and functional building. copyright 1997 American Institute of Physics.
1996-11-06
Preparation of wood-polymer composites by using ionizing radiation
International Nuclear Information System (INIS)
Radiation-initiated polymerization of styrene and acrylic acid in poplar wood were investigated for the preparation of wood-polymer composites. The direct irradiation method was applied to the monomer adsorbed poplar wood specimens. 8000 Ci "6"0Co source at a dose rate of about 0.4 Mrad/h was used. Furthermore the effects of carbon tetrachloride, methanol, dioxane and acrylonitrile on styrene polymerization were investigated and the reaction rates were calculated for each case. The influence of CCl_4 (10%) on acrylic acid polymerization in poplar wood was also determined. (author).
1982-05-01
Optimum plasma conditions for the efficient high-order harmonic generation in platinum plasma
International Nuclear Information System (INIS)
We studied the optimum plasma conditions that are required for efficient high-order harmonic generation in platinum plume. Harmonics up to the 49th order (?=16.32 nm) are analyzed under various conditions of laser-plasma interaction. Time-resolved ultraviolet spectra of platinum plasma at both optimum and nonoptimum conditions of harmonic generation are presented. We calculated the ionization states of the plasma, free electron density, and singly charged ion density at different prepulse intensities and compared them with experimental results.
2007-06-01
Microscopic model for the higher-order nonlinearity in optical filaments
Using an exactly soluble one-dimensional atomic model we explore the idea that the recently observed high-order nonlinearity in optical filaments is due to virtual transitions involving the continuum states. We show that the model's behavior is qualitatively comparable with the experimentally observed cross-over from self-focusing to de-focusing at high intensities, and only occurs at intensities which result in significant ionization. Based on these observations, we conjecture that this continuum electron nonlinear refraction exhibits strong memory effects, and most importantly, the change of its sign is effectively masked by the de-focusing due to free electrons.
2010-01-01
Mechanical variations of diffused plasma parameters in a double plasma device
International Nuclear Information System (INIS)
Experimentally it is shown that a movable grounded metallic plate placed inside a multi-dipole magnetic cage can vary the diffused plasma parameters such as density, plasma potential and electron temperature. Plasma is solely produced in the source section of a double plasma device by a dc hot filament discharge and a low-density plasma is produced in the target section by local ionization of neutral gas by the high energetic electrons coming from the source section. A grounded movable stainless steel plate is inserted in the target section of the device. The floating potential of the plate also changes depending on the position of the plate inside the magnetic cage.
2007-06-21
Ionization and fragmentation of DNA, RNA bases induced by proton impact
Energy Technology Data Exchange (ETDEWEB)
We present recent results obtained in the Toulouse's group that deal with proton to base and nucleoside interactions. We stress the weakness of the sugar part in the nucleoside, i.e. the uridine molecule under scrutiny. Since some parts of the fragmentation spectrum correspond to the fragmentation of a 'pure' uracil molecule, i.e. the RNA base, an 'additivity rule' seems to prevail for the nucleoside, something that still has to be confirmed. Moreover, some results that deal with the secondary electronic emission from uracil are also displayed.
2008-02-01
International trends in radiation protection
International Nuclear Information System (INIS)
The great uranium debate throughout the industrialised world has intensified awareness of the biological hazards from ionizing radiation. It is therefore appropriate to use this awareness to draw attention to medical X-Radiation which today represents the most significant risk to future generations. There is ample legislation to control proliferation of nuclear development but in diagnostic radiology proliferation is unlimited; most international surveys indicate an unchecked annual growth rate of 15%. The article looks at risk hypotheses, dose measurements and the responsibilities of practising radiographers, and also reviews the international situation as reported at the 1977 world congress of radiation protection.
International Nuclear Information System (INIS)
The additional error in measurement of the thickness of Kh18N10T steel for possible changes in composition with an energy of the photons of ionizing radiation of 10-80 keV was evaluated. The desirability of use of a type REIS-I x-ray emitter in measurement of the thickness of steel up to 1 mm is shown. The instrument provides measurement of the thickness of steel in the 0.1-1.0 mm range with a reproducibility of the results with an error not exceeding 0.5-1.0%. The measurement error with corrugations characteristic of bellows does not exceed 5%.
International Nuclear Information System (INIS)
This article considers the application of simple trial wave functions to calculate the ground state energy of a hydrogen-like center near the interface of two media. Calculations have been performed taking into account the image potential. It has been shown that different kinds of wave functions are optimal at different distances from the interface. A relatively simple wave function has been suggested to represent main features of the dependence of the ground state energy on the distance to the interface. (authors)
2009-01-01
International Nuclear Information System (INIS)
The document represents a guide for the external decontamination of persons accidentally radio contaminated due to the use, production or transport of radioactive materials. The general conditions, from the medical point of view, to be kept in mind, in the event of accidental overexposures as decontamination treatment and the handling of samples are detailed throughout report. The external contamination without injury in skin or with wound its considered. The distribution of measures and responsibilities for the therapy of the irradiated patients with radioactive materials are enumerated. The preparations of decontaminate solutions are detailed in this work. Moreover, forms for the reception, physical evaluation of the patient and external contamination are presented. (author)
Free radicals and their transformations in irradiated proteins
International Nuclear Information System (INIS)
Experimental investigation data are systematized of free radical states and processes in irradiated proteins. The investigation is performed by the radiospectral methods. Results are discussed in detail of the study of free radicals electronic structure of amino acids, peptides and proteins formed by the action of ionizing radiation. The specificity is stressed of the study of monocrystalls of these compounds by the method of electronic paramagnetic resonance. The nature is also studied of primary centres formed under the effect of radiation on biologically important compounds and their subsequent reactions in solid and liquid solutions. Ion-radical states of different functional groups of the protein molecule are studied. Prospects of the study and the role of anion-radicals in biological processes are discusses.
Formation of charge and energy distribution of heavy ions in substance according to diffusion model
International Nuclear Information System (INIS)
The formation of the ions charge and energy distributions of the ions slowed down or randomly changing their charge in the collisions with the medium particles are studied. The effect of the ions dispersion by the charge on the Bragg curve form is investigated. The proposed diffusion approximation for the heavy ions kinetic equation makes it possible to determine simply the parameters of the ions distribution by charge and energy on the whole way of the ions motion. The relation between the ions charge distribution characteristics and the cross sections of the ionization-recombination processes is indicated. The ions distributions, calculated in the proposed analytical model, are compared with the results of the numerical calculations. Good agreement between the analytical, numerical and experimental results is obtained
2003-11-01
Energy Levels of Phosphorus, P I through P XV
Energy level data are given for the atom and all positive ions of phosphorus (Z = 15). These data have been critically compiled, mainly from published and unpublished material on measurements and analyses of the optical spectra. We have derived or recalculated the levels for a number of the ions. In addition to the level values in cm/sup -1/ and the parity, the J value and the configuration and term assignments are listed if known. Leading percentages from the calculated eigenvectors are tabulated or quoted wherever available. Ionization energies are given for all spectra.
1985-07-01
Emittance characteristics of negative ion beams generated by the sputter technique
Energy Technology Data Exchange (ETDEWEB)
Average emittance data for ion beams extracted from cesium-sputter negative ion sources equipped with spherical, ellipsoidal, and cylindrical geometry cesium-surface ionizers are presented. The attributes of the respective source geometries are described in terms of their cesium ion optical properties. The results of recent measurement of the emittances of momentum-analyzed beams extracted from the ellipsoidal geometry source are also presented. These measurements indicate the presence of a species-dependent effect. The effect is believed to be attributable to differences in the energy spreads of the respective negative ion beams introduced by the sputter generation process.
1990-01-01
Emittance characteristics of negative ion beams generated by the sputter technique
Energy Technology Data Exchange (ETDEWEB)
Average emittance data for ion beams extracted from cesium-sputter negative ion sources equipped with spherical, ellipsoidal, and cylindrical geometry cesium-surface ionizers are presented. The attributes of the respective source geometries are described in terms of their cesium ion optical properties. The results of recent measurement of the emittances of momentum-analyzed beams extracted from the ellipsoidal geometry source are also presented. These measurements indicate the presence of a species-dependent effect. The effect is believed to be attributable to differences in the energy spreads of the respective negative ion beams introduced by the sputter generation process. 11 refs., 8 figs.
1989-01-01
International Nuclear Information System (INIS)
Mass spectrometry was instrumental in the discovery of the fullerenes and the characterization of their special structure (truncated icosahedron). High resolution and high sensitivity mass spectrometry in combination with a crossed molecular beam/electron beam ion source is used here to study a further, very unique property of singly and multiply charged fullerene ions (up to Z=7), i.e. their strong resilience towards decomposition via sequential C_2 evaporation and via Coulomb explosion, respectively. (author).
1994-03-20
Electron Beam and Gamma Radiolysis of Solid-State Metoclopramide
British Library Electronic Table of Contents (United Kingdom)
Purpose Study the radiolysis of solid-state metoclopramide hydrochloride at various absorbed doses. Elucidate the structure of the degradation products to gain information on the radiolysis mechanisms. Methods Solid-state metoclopramide samples were irradiated at several doses with gamma rays and high-energy electrons to evaluate the influence of the dose rate. High-performance liquid chromatography with a diode array detector was used to measure the chemical potency as a function of the absorbed dose and to quantify the degradation products. The characterization of degradation products was performed by liquid chromatography/atmospheric pressure chemical ionization/tandem mass spectrometry. Results The degradation of solid-state metoclopramide after irradiation was negligible. No qualitati...
2006-01-01
Energy Technology Data Exchange (ETDEWEB)
A study is made of plant sensitivity to mutagens during the processing of seeds. An examination is made of problems concerned with modification mutability, the nature of plant restoration following irradiation. Particular attention is given to mutation changes. A presentation is made of several features of mutant changes initially selected by separate indicators. An examination is made of the possible study of mutant indicator genetics. General data on the forms and varieties produced by the mutagenesis method are given. The book is designed for breeding specialists and geneticists engaged in the study of mutagenesis. 439 references, 27 figures, 66 table.
1981-01-01
ESR spectra of radicals of gamma-irradiated wood and cellulose
International Nuclear Information System (INIS)
Spectra of e.p.r. radicals in cellulose and timber gamma-irradiated at 77 and 300 K have been measured. Radiation yields and the kinetics of radicals accumulation have been studied. The effect of ionizing radiation on cellulose is the appearance of radicals resulting from rupture of C-H bonds in positions 1 and 4. Timber, additionally, forms ''lignin'' radicals. A mechanism of cellulose and timber radiolysis is suggested. ''Lignin''-type compounds present in timber protect polysaccharides from radiation-induced destruction.
Determination of the cell and mucous distribution in the airways of the lung
International Nuclear Information System (INIS)
Models of the human airways have played a major role in evaluating the health effects of inhaled radionuclides. While models such as those of Weibel (1963) provide data necessary for characterizing deposition of aerosol, they have not characterized the cells at risks in the airspaces. Given the advancements in techniques and study of cell cultures exposed to ionizing radiation there is a need to extrapolate between the simple structures of cell culture systems and the complex architecture of the human airways. The preliminary data in this paper provide a complete characterization of the size and number of cells in the airways and represents a significant advance in our study of the health consequences of exposure to inhaled radionuclides. 26 refs., 2 figs., 4 tabs.
1991-01-01
International Nuclear Information System (INIS)
Remote-controlled handling systems are required for work to be done in the decommissioning and dismantling of nuclear facilities. These systems are equipped with electronic devices suitable for use in working environments affected by ionizing radiation. The publication explains the step-wise progress achieved for improving the radiation resistance of electronic devices with the example of a four-quadrant controlling device for the motors of a manipulator. The radiation resistance of the device could be enhanced to radiation energies of 5.500 Gy. This means that a manipulator vehicle equipped with this controlling device can take up to approx. 15 kGy all in all, taking into account its own shielding properties. (DG).
Characterization of nuclear fuels by ICP mass-spectrometric techniques
British Library Electronic Table of Contents (United Kingdom)
Isotopic analyses of radioactive materials such as irradiated nuclear fuel are of major importance for the optimization of the nuclear fuel cycle and for safeguard aspects. Among the mass-spectrometric techniques available, inductively coupled plasma mass spectrometry (ICP-MS) and thermal ionization mass spectrometry are the most frequently applied methods for nuclear applications. Because of the low detection limits, the ability to analyze the isotopic composition of the elements and the applicability of the techniques for measuring stable as well as radioactive nuclides with similar sensitivity, both mass-spectrometric techniques are an excellent amendment to classical radioactivity counting methods. The paper describes selected applications of multicollector ICP-MS in combination with c...
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
Long-Range Alpha Detector (LRAD) systems are designed to monitor alpha contamination by measuring the number of ions in the air. Alpha particles are a form of ionizing radiation and a typical 5-MeV alpha particle will create about 150,000 ion pairs in air. Field tests at various DOE sites have shown that LRAD Surface Soil Monitors (SSM), Sample Monitors, and Object Monitors are faster and more sensitive than traditional alpha detectors for measuring alpha contamination. This paper discusses the various applications of LRAD technology to low-level radioactive waste management.
1993-12-01
M-shell x-ray production by 0.6--4.0-MeV protons in ten elements from hafnium to thorium
International Nuclear Information System (INIS)
M-shell x-ray production cross sections for selected heavy elements, namely, _7_2Hf, _7_3Ta, _7_4W, _7_5Re, _7_6Os, _7_7Ir, _7_8Pt, _7_9Au, _8_3Bi, and _9_0Th, were measured for protons of energy 0.6--4.0 MeV. The experimental results are compared with the predictions of the first Born and semiclassical approximations for M-shell ionization; these data are also compared with the theory that accounts for the projectile's energy loss and Coulomb deflection as well as for the target's M-shell electron perturbed stationary state and relativistic nature (ECPSSR). Generally, fair agreement between the data and the ECPSSR theory is found. Some systematical discrepancies observed for the lightest elements (Hf, Ta, and W) are explained as possible ambiguities in the M-shell Coster-Kronig factors and fluorescence yields, which were used to convert theoretical M-subshell ionization cross sections to the total M-x-ray production cross sections. The ...
Ionizing radiation-induced mutation of human cells with different DNA repair capacities
Energy Technology Data Exchange (ETDEWEB)
We have observed significant differences in the response to ionizing radiation of two closely related human cell lines, and now compare the effects on these lines of both low and intermediate LET radiation. Compared to TK6, WTK1 has an enhanced X-ray survival, and is also more resistant to cell killing by {alpha}-particles. The hprt locus is more mutable in WTK1 than in TK6 by both X-rays and {alpha}-particles. WTK1 is also more mutable by {alpha}-particles than by X-rays at the hprt locus. X-ray-induced mutation at the heterozygous tk locus in WTK1 is about 25 fold higher than in TK6, while {alpha}-particle-induced mutation is nearly 50 fold higher at this locus. Also, the slowly growing tk- mutants, which comprise the majority of spontaneous and X-ray-induced tk- mutants of TK6, were not induced significantly by {alpha}-particles. Previously, we showed that TK6 has a reduced capacity for recombination compared with WTK1, and therefore, these results indicate that ...
1994-12-31
Energy Technology Data Exchange (ETDEWEB)
The diminishing clean oil reserve is driving the search for new or improved ways to reduce the level of NSO-containing species found in high abundance in heavy crude oils. Hydrotreatment is the currently preferred technique to remove those polar species. Unfortunately, nitrogen-containing compounds cause coke formation on the surface of the hydrotreatment catalyst, leading to partial or complete deactivation. Here, positive- and negative-ion electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI FT-ICR MS) identify those nitrogen compounds that resist hydrotreatment. ESI preferentially ionizes polar (e.g., heteroatom-containing) species: basic molecules are detected as positive ions and acidic/neutral molecules as negative ions. FT-ICR MS resolves thousands of species in a single mass spectrum, allowing for unambiguous determination of elemental composition, C{sub c}H{sub h}N{sub n}O{sub o}S{sub s}, for ...
2006-10-15
High frequency breakdown voltage
Energy Technology Data Exchange (ETDEWEB)
This report contains information about the effect of frequency on the breakdown voltage of an air gap at standard pressure and temperature, 76 mm Hg and O{degrees}C, respectively. The frequencies of interest are 47 MHz and 60 MHz. Additionally, the breakdown in vacuum is briefly considered. The breakdown mechanism is explained on the basis of collision and ionization. The presence of the positive ions produced by ionization enhances the field in the gap, and thus determines the breakdown. When a low-frequency voltage is applied across the gap, the breakdown mechanism is the same as that caused by the DC or static voltage. However, when the frequency exceeds the first critical value f{sub c}, the positive ions are trapped in the gap, increasing the field considerably. This makes the breakdown occur earlier; in other words, the breakdown voltage is lowered. As the frequency increases two decades or more, the second critical frequency, f{sub ce}, ...
1992-03-01
Energy Technology Data Exchange (ETDEWEB)
Acidic constituents in crude oil are associated with the formation of stable emulsions during production and present a challenge for efficient oil recovery and processing. Acid molecules, including naphthenic acids and acidic sulfur in crude oil cause corrosion in refineries and pipelines. Naphthenic acids are also significant because of their surface activity and marginal water solubility, so that they may leach to wastewaters and cause adverse environmental effects. Acidic components of oil are not limited to carboxylic acids but also molecules that contain sulfur and nitrogen. As such, an improved understanding of the chemistry and physics of petroleum at the molecular level is needed in order to understand the range of problems associated with acidic oil components and to design better solutions. The applications of negative-ion electrospray ionization (ESI) Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) for speciation of acidic oil ...
2008-07-01
Energy Technology Data Exchange (ETDEWEB)
In technical combustors, flow and combustion processes inside the combustion chamber determine the design and also the safety of the plant. A modelling technique was developed at TU Dresden which comprises both numerical simulations and experimental data and thus achieves a high degree of transparency in its visualisation of the processes inside the combustion chambers under investigation. With the experience gained, numerical models of commercial simulation software (FLUENT, CFX) can be validated by measured values, and potential applications of the programs can be investigated. The first stage of experimental modelling consisted in isothermal (cold) modelling in consideration of flow-relevant similarity characteristics. In the reactive, non-isothermal models, the fuel/air ratio and temperature conditions inside the original combustion chamber were modelled as well. In order to obtain detailed data on the combustion ...
1998-05-26
[The contribution of the Military Medical Academy to space exploration].
The article examines the contribution of the Military Medical Academy as an educational, research and medical institutions in the establishment and development of the national Russian manned spaceflight. Lists the names of the Academy's scientists, working in laboratories and in the Cosmonaut Training Center. In 1958 the academy was formed Department of Aviation Medicine from the research laboratories of aviation medicine, psychophysiology, and encephalography, a division of pressure chambers and furnaces. Direct contribution to the preparation of the first manned space flight made by graduates of the academy, E.A. Karpov (the first chief of Cosmonauts Training Center. Yuri Gagarin) and I.A. Kolosov. Over the half century history of the Russian Space Military Medical Academy, prepared and sent to the CPC Gagarin more than 110 of its graduates. PMID:21770320
2011-04-01
[Study of body composition by potassium-40 measurement in patients with breast and uterine cancer].
Total potassium was assayed in 150 normal weight and obese females (cervical carcinoma-52, endometrial carcinoma-25 and breast cancer-73) by measurements of 40K spontaneous radiation in a low-background chamber. Control group included 30 healthy and 25 obese females. Computations of body cell and extracellular mass and fat were carried out on the basis of the said measurements. Extracellular fluid volume was measured in 38 patients by X-ray fluorescence method using sodium bromide. The results pointed to a body cell mass deficit matched by increased extracellular mass due to a higher fat level in patients with breast, endometrial and cervical carcinoma. The said correlation was particularly pronounced in obese patients. The beneficial effect of treatment was more often observed in patients with normal body weight. PMID:3739295
1986-01-01
Total cross sections of ultracold neutron interactions with some gases
Energy Technology Data Exchange (ETDEWEB)
Measurement results of total interaction cross sections averaged by the spectrum of ultracold neutrons (UCN) within the rate range from 3.2 to 5.7 m/s at the temperatures of 80 and 300 K for the following gases: hydrogen, parahydrogen, helium-4, nitrogen, neon, argon, xenon are presented. The experiment has been conducted conducted in the facility for UCN extraction, mounted in the radial channel of the WWR-K reactor. Experimental dependences of UCN counting rate on pressure of the investigated gases in the chamber varying from 0 to 1.5x10/sup 3/ torr are presented graphically. The measured total cross sections mainly satisfactorily agree with calculations, divergences are observed only for hydrogen and xenon.
1981-11-01
Studies of basic parameters of electron-counting detection
International Nuclear Information System (INIS)
Measurements have been made of certain parameters relevant to the operation of electron-counting detectors. An experimental chamber consisting of a uniform-field drift tube and a coaxial proportional counter thas been employed to obtain data, at very low drift fields (E/p<0.02 V/cm Torr), on electron mobility and lifetimes in a range of gas mixtures. These mixtures included argon, methane, nitrogen and carbon dioxide. Measurements of single-electron spectra showed that, unexpectedly for the standard gas mixtures employed, useful departure from an exponential spectrum was not possible without the production of cathode secondaries. Although the present studies employed only the counter electrical signal the information obtained should be directly relevant to the operation of practical light-pulse systems. Examples of electron-counting spectra for soft X-rays are shown. (orig.).
1990-05-21
British Library Electronic Table of Contents (United Kingdom)
This work reports the development of an automatic methodology based on the use of 1-anilinonaphthalene-8-sulfonate (ANS) as an interfacial fluorescent probe for detecting the hydrophobic environment shift around the probe, caused by the hydrolytic action of PLA2 on the liposomes. The implementation of this reaction in a sequential injection analysis (SIA) system along with the use of the mixing chambers permitted the evaluation of PLA2 activity and assessment of the inhibitory effect of the non-steroidal anti-inflammatory drugs (NSAIDs) on PLA2 activity. Several studies were performed with the aim of establishing the appropriate flow system configuration: the liposome substrate; PLA2 and ANS optimum concentrations and incubation times before and after the enzyme addition. Based on these st...
2009-01-01
International Nuclear Information System (INIS)
A comprehensive assessment on the eligibility of reduced activation (RA) steels as structural chamber material in Inertial Fusion Energy thick-liquid concepts is performed. As far as alloying elements, it is shown that the activation of tungsten is a question to discuss. Regarding impurity elements, it is analyzed if they could question the possibility of obtaining real RA steels for shallow land burial (SLB). The effect of the thickness of the liquid wall on the SLB response of alloying and impurity elements is computed. It seems that a reasonable liquid thickness of about 80 cm is allowable to obtain SLB acceptability of real RA steels. And above all, we have estimated the impact of cross section uncertainties when addressing the former questions, and we identify those to be improved. The necessary improvement of some tungsten and niobium cross sections is justified. (authors)
2006-06-01
Safety testing of 18650-style Li-Ion cells
Energy Technology Data Exchange (ETDEWEB)
To address lithium-ion cell safety issues in demanding power applications, electrical and thermal abuse tests were performed on 18650 sized cells. Video and electrically monitored abuse tests in air included short circuit, forced overcharge, forced reversal, and controlled overheating (thermal) modes. Controlled overheating tests to 200 C were performed in a sealed chamber under a helium atmosphere and the gases released from the cell during thermal runaway were analyzed at regular intervals using gas chromatography and mass spectrometry. In addition to alkane and alkene solvent breakdown fragments, significant H{sub 2} was detected and evidence that HF was evolved was also found.
2000-06-08
Quantifying the thermal flowering rates of eighteen species of annual bedding plants
British Library Electronic Table of Contents (United Kingdom)
The effect of mean daily air temperature (MDT) on flowering rate (the reciprocal of days to flower) was quantified for 18 species of annual bedding plants. Plants were grown in environmental growth chambers at constant air temperature set points of 5, 7.5, 10, 15, 25, or 30^oC and under an irradiance of 160-180mmolm^-^2s^-^1, with a 16-h photoperiod. Nonlinear mathematical equations were developed to predict the effect of MDT on flowering rate and to estimate the base, optimum, and maximum temperatures (Tmin, Topt, and Tmax), which are the temperatures at which flowering rates are zero (low temperature), maximal, and zero once again (high temperature), respectively. The estimated Tmin varied among species and ranged from 1.1^oC in French marigold (Tagetes patula L.) to 9.9^oC in angelonia ...
2011-01-01
Partial natural-gas firing of a cupola furnace. Delvis naturgasfyring af kupolovne; Litteraturstudie
Energy Technology Data Exchange (ETDEWEB)
A survey was undertaken of literature on the conversion of coke-fired cupola furnaces so that they can be fuelled, either wholly or partially, with natural gas. The aim was to determine the most suitable method for a specific furnace. Substitution with natural gas can result in speedier adjustment and control of the smelting process and in addition operational costs are reduced as natural gas is a cheaper fuel. The payback period would be one year. Pollutive emissions would be reduced. It was concluded that the most satisfactory solution would be that 3-4 gas burners should be placed immediately above the smelting zone in the furnace. Each burner should be placed in a separate combustion box in which the complete combustion process could take place. The burners should be placed symmetrically about the furnace, pointing at a small degree downwards. In this way the combustion chamber will not be filled with materials from the furnace and the burners will not be ...
1992-12-01
Numerical analysis of methane-air combustion considering radiation effect
Energy Technology Data Exchange (ETDEWEB)
Turbulent premixed methane-air combustion in a cylindrical chamber is numerically simulated considering radiation effect. Reaction rates are considered as minimum rates between Arrhenius rates and eddy break up rates. A five step reduced mechanism is used. Turbulent modeling is done via standard k-{epsilon} model imposed by empirical inlet boundary conditions. Source terms of energy equation consist of reaction rates and radiation effects. The discrete ordinate method (DOM) is employed to solve the radiative transfer equation (RTE) and the weighted sum of gray gas model (WSGGM) is imposed to consider radiation effect of non-gray gases. The results indicate that in the case of turbulent combusting flows, the effect of radiation of gases can affect the temperature and species concentrations. The numerical results obtained considering radiation effect are closer to the experimental data than that of the case without radiation effect. (author)
2008-12-15
Numerical analysis of methane-air combustion considering radiation effect
International Nuclear Information System (INIS)
Turbulent premixed methane-air combustion in a cylindrical chamber is numerically simulated considering radiation effect. Reaction rates are considered as minimum rates between Arrhenius rates and eddy break up rates. A five step reduced mechanism is used. Turbulent modeling is done via standard k-? model imposed by empirical inlet boundary conditions. Source terms of energy equation consist of reaction rates and radiation effects. The discrete ordinate method (DOM) is employed to solve the radiative transfer equation (RTE) and the weighted sum of gray gas model (WSGGM) is imposed to consider radiation effect of non-gray gases. The results indicate that in the case of turbulent combusting flows, the effect of radiation of gases can affect the temperature and species concentrations. The numerical results obtained considering radiation effect are closer to the experimental data than that of the case without radiation effect.
2008-12-01
Modeling of Valveless Micropumps
British Library Electronic Table of Contents (United Kingdom)
There are two difficulties encountered in modeling valveless micropumps using lumped-element methods. The pressure loss coefficient for fluidic diodes used in valveless pumps to rectify flow depends on the flow direction. A problem arises in choosing the proper loss correlation because the flow direction is not known a priori. Another problem is the quadratic form of the equation for the flow through the fluidic diodes, which brings about multiple solutions. The above problems become even more serious in multi-chamber cases. They are overcome in this study by suitably formulating the flow resistance. In addition, the flow inertia is accounted for in the unsteady model. The steady and unsteady models are evaluated by comparing with CFD simulations, which also serve to illustrate the flow fi...
2009-01-01
Investigation on corrosion resistance of amorphous films prepared by ion beam mixing
International Nuclear Information System (INIS)
Fe-Cr amorphous films have been formed by both in situ evaporation of multilayered films and ion beam mixing in a target chamber of a 200 keV implanter. The effects of Cr content and ion irradiation on the amorphization of films were examined by transmission electron microscope (TEM). Corrosion of film was investigated by means of a potential dynamic polarization. Corrosion resistance of amorphous film in 0.5 mol H-2SO-4 solution is considerably increased than that of pure iron. Using X ray photoelectron spectroscopy (XPS) corrosion resistance in atmosphere of amorphous Fe-Cr passive films formed by P"+ mixing was studied. Results show that the richness of Cr and P exist at the surface of Fe-Cr film.
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
An experiment lasting a number of hours was carried out with 6 men under standardised climate chamber conditions to find out to what extent wallpaper that reflects about 65-75% in the infra-red range by comparison with normal wallpaper that reflect only 3-5% of heat, has measurable positive effects on the thermoregulation of the human body and the human sensation of temperature. The measurements of skin temperature and heat flow intensity in the deeper areas of the body and the periphery, and metabolic heat conversion measurements (indirect calorimetry) confirm that infra-red reflection of the heat irradiated from the body lead to a measurable heat recovery on the body surface with a reduction of metabolic conversion. It was proved that it is possible to reduce the average room temperature by up to 4 K whilst maintaining the same degree of thermal comfort, which corresponds to a 20% saving in heating energy. (orig./BWI).
1985-06-01
High-specific-output diesel engines
Energy Technology Data Exchange (ETDEWEB)
The diesel engine is the most efficient device for converting chemical energy stored in liquid hydrocarbon fuels into useful work. Up to 50% of the energy in the fuel is converted into output shaft work. The modern diesel engine is twice as efficient as the early diesel engines and produces as much as sixty times as much power for a given cylinder size. These developments have, in recent years, been accompanied by a substantial reduction in the noxious elements in the exhaust gas so that engines are now, relatively speaking, ecologically clean. The developments have centred around exhaust gas turbocharging and improved fuel injection systems, but recent work on low-heat-rejection engines has resulted in significant advances in structural ceramics and in high-temperature lubricating oil, as well as an enhanced understanding of heat transfer in high-temperature combustion chambers. (author).
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
The Bureau of Mines has investigated the hazards of military explosives dispersed as dust clouds in a 20-L test chamber. For purposes of personnel safety, the spark ignitability of the explosives in the form of unconfined dust layers was also studied. The 20-L data show that most of the explosives dusts were capable of sustaining explosions as dust clouds dispersed in air and some dusts were even capable of sustaining explosions when dispersed in nitrogen. The finest sizes of explosives dusts were less reactive than the larger sizes; this is opposite to the particle size effect observed previously for the pure fuel dusts. The data for the explosives dusts were compared to those for pure fuel dusts. 27 refs., 47 figs.
1989-01-01
GPM on The High Capapcity Centrifuge
National Aeronautics and Space Administration (NASA)
GPM moves from the clean room to the test chamber on a dolly without wheels. Compressed air is pumped out under airpads that float the Spacecraft on a bed of air. nThe wind generated when the centrifuge moves at its maximum speed are more than 200 mph - that's tornado speed. But since they move with the centrifuge the satellites tested only feel 20 mph winds. nLeaning outward at 45 degrees for one test orientation, GPM comes within 28 inches of the wall. When lifted onto the platform it cleared the ceiling by only five inches. nNatural audio only. nVideo Credit: Brooke Harris n
2011-10-19
Fractality in high energy cosmic rays
Energy Technology Data Exchange (ETDEWEB)
Using EAS data from the EAS-EXC group (EAS plus hadronic calorimeter and nuclear emulsion-X chamber hybrid experiment) on Mount Chacaltaya during the 1990's the fractal properties of the energetic cosmic ray fluxes was investigated. A discrimination in the hadron content of the energetic primaries furnishes two different data samples, the total EAS fluxes and the hadron-less fluxes. The sidereal diurnal variation of the hadron-less EAS time variation shows values of 0.5% with a phase at about 2.29 hr sidereal time. With the help of the Crassberger Procaccia algorithm the fractal dimensions have been investigated of, on the one hand, the differences in arrival times of the hadron-less showers and on the other hand the EAS fluxes time series with an integration time of five min. The obtained fractal dimensions show inconclusive evidence of continuous chaotic component in the data samples investigated.
2003-07-01
International Nuclear Information System (INIS)
Purpose: To obtain stabilized operation by preventing over heat in emergency cooling pumps upon accidents of flow regulators. Constitution: A pressure suppression chamber pool and a pressure vessel are communicated to each other with a pipeway and the water in the suppression pool is charged by a charging pump to the pipeway. The pipeway is interposed with an emergency cooling pump so as to feed water in the pipeway to the pressure vessel and a water source and the emergency cooling pumps are connected by way of a closed pipeway. Further, the closed pipeway and the pipeway interposed with the charging pump are communicated to each other by way of a connecting pipeway, to which are interposed an instrument for detecting the increase in the temperature of the emergency cooling pumps due to abnormality in the closed pipe (such as troubles in flow regulators) and outputting control signals and an electrically actuated valve controlled by a control device. (Furukawa, ...
Effects of continuous exposure to carbon monoxide on auditory vigilance in man
Energy Technology Data Exchange (ETDEWEB)
Six different groups of non-smoking young male subjects were studied separately for 18 consecutive days each in a closed controlled-environmental human exposure chamber. Each group was subjected to a 5-day control period in fresh air followed successively by an 8-day period of continuous exposure to 50 ppm, 15 ppm or 0 ppm (control) by volume of carbon monoxide (CO) in air, and a 5-day recovery period in fresh air. The subjects performed a 1-h auditory vigilance task every day at the same time of day in a fixed qualitative, quantitative, and temporal relationship with food intake, consumption of stimulating beverages, physical activity, and sleep. It was concluded that such CO exposure, involving the continuous carriage of carboxyhaemoglobin loads up to 7%, was without significant effect on auditory vigilance.
1981-01-01
Chemical and physical conversion in cold atmosphere and the effect of radiation
Energy Technology Data Exchange (ETDEWEB)
The project is focusing on the formation and growth mechanisms of atmospheric aerosol and cloud droplets. Both aerosol particles and cloud droplets affect strongly on the atmospheric radiation fluxes by scattering and absorption. The droplet formation results from physical and chemical processes occurring simultaneously. The studies concerning the tropospheric cloud droplet formation, laboratory experiments with a cloud chamber and stratospheric cloud formation are summarized. The recent studies summarized in this presentation indicate that both aerosol particles and cloud droplets have a significant role in climatic change and ozone depletion problems. The anthropogenic emissions of gaseous and particulate pollutants change the properties of atmospheric aerosols and cloud droplets. The research in this field will be continued and more quantitative understanding based both experimental and theoretical studies is required
1996-12-31
Characterization of the combustion of biomass producer gas in a constant volume combustion bomb
British Library Electronic Table of Contents (United Kingdom)
In this article a methodology is presented for studying the influence of the biomass moisture content and the biomass/air ratio on the producer gas composition and on the chemiluminescent emissions during the combustion process. Firstly, a mathematical model based on the thermo-chemical processes inside the gasifier is used to predict the composition of the producer gas as a mixture of CO, CO2, H2, N2, CH4 and H2O gases. Secondly, the predicted composition is introduced into a constant volume combustion bomb (CVCB), which simulates the typical conditions inside the combustion chamber of an internal combustion engine, in order to characterize its combustion under gasoline-type conditions through the instantaneous pressure and the detection of the spontaneous luminous radiation (chemilumines...
2010-01-01
Barriers for radon in uranium mines. Report of investigations 1977
International Nuclear Information System (INIS)
Water-based epoxy sealants were examined during a 2-year period to determine their effectiveness as barriers to radon release in uranium mines. Radon emanation rates from uranium ore samples were monitored for extended periods in the laboratory before and after sealant application. Reduction of radon flux due to the coating of lab samples was approximately 80 percent. Test chambers in a dormant uranium mine were monitored to determine both short and long-term barrier effectiveness. These field studies of the sealants indicated reductions greater than 50 percent relatively soon after application and nearly 75 percent more than 1 year later. An unexpected complication to early monitoring in the form of a large radon emanation increase, believed due to added moisture, is discussed.
Anderson introduces a new biomass baler
Energy Technology Data Exchange (ETDEWEB)
Canadian-based Anderson Group Company has developed an innovative round baler for harvesting a large variety of woody biomass. The baler was initially developed in 2005 in collaboration with the University Laval and Agriculture and Agri-Food Canada. The third generation BIOBALER{sup TM} is currently built, engineered and commercialized by Anderson. It can produce up to 40 bales/hr in short rotations woody crops such as willow and hybrid poplar. The unit can harvest brushes up to 125 mm in diameter. A standard tractor can pull the BIOBALER in fallow or abandoned land, under power transmission lines, and between planted trees. The patented BIOBALER includes a mulcher head attachment, a choice of long or short swivel tongue, a fixed chamber and an undercarriage frame.
2010-07-01
A semi-micro combustion assembly for the determination of carbon and hydrogen in actinide compounds
International Nuclear Information System (INIS)
A rapid combustion unit (Baird and Tatlock) incorporating a combustion chamber provided with baffle plates for complete combustion of the sample without the use of a catalyst has been assembled in a glove box for the determination of carbon and hydrogen in actinide complexes. The unit has been modified employing a movable electric furnace and a proportional temperature controller, for decomposition of the sample at desired heating rates. The set-up was standardised employing various reference materials such as benzoic acid, acetanilide, sulphanilamide and 1-chloro 2:4 dinitrobenzene and the standard deviation in the measurements evaluated. It has also been used successfully for the determination of carbon in uranium carbide and carbon and hydrogen in some uranyl-#beta#-diketone-amine N-oxide complexes and in plutonium(IV) oxalate. (auth.).
1982-09-01
Website Policies and Important Links Comments