Some aspects of molecular mechanisms common to radiation and chemical carcinogenesis are discussed, particularly the DNA damage done by these agents. Emphasis is placed on epidemiological considerations and on dose-response models used in risk assessment to extrapolate from experimental data obtained at high doses to the effects from long-term, low-level exposures. 3 references, 6 figures. (ACR)
Conference abstract book contains seven sections: Plenary-4 abstracts; Chemical-9 abstracts; Radiation-7 abstracts; Ultra Low Doses and Medicine-6 abstracts; Biomedical-11 abstracts; Risk Assessment-5 abstracts and Poster Sessions-25 abstracts. Each abstract was provided by the author/presenter participating in the conference.
The aim of this work is to determine and compare the dosimetric properties of NaCl and KCl samples using infrared-stimulated luminescence (IRSL) technique. For a material to be used as dosimeter, both the IRSL temperature dependence and the radiationdoseresponse have critical importance. In this work the IRSL characteristics from NaCl and KCl samples were experimentally investigated as a function of temperature and laboratory radiation doses. Dosimetric properties of NaCl and KCl samples were found significantly different. The IRSL signals displayed by NaCl were found to be more stable, reliable and agreeable than those of KCl.
The analysis described demonstrates the use of benefit/cost sensitivity analysis in examining the wide range of potential damages and savings associated with converting oil-fired electric utility boilers to burn coal in Florida. This model, for the first time incorporates, in quantitative terms, environmental economic externalities into a benefit/cost ratio sensitivity analysis framework. Five different dose-response estimates of morbidity and mortality costs, property devaluation, and willing-to-pay estimates are used in combination with four acid rain dose-response models to estimate the net present worth of externality costs. The model estimates the net present worth of benefits by incorporating into a dynamic framework all relevant construction, O + M, and fuel costs of converting an electrical generation facility from using oil to coal. These benefits of fuel savings are then weighted against various combinations of ...
The rate was studied of radiation destruction of phenol aqueous solutions at a concentration range of 1 to 100 ppm. Irradiated were model solutions containing additions of some organic and inorganic substances typical of the petrochemical industry. In view of the fact that the radiation destruction kinetics is determined by the amount of dissolved oxygen in the sample and by the phenol concentration, relatively low doses were used. Thus, a sufficient amount of oxygen in the sample and therefore the oxidation mechanism of radiolysis were ensured. The dose-response relationships for phenol destruction were studied using doses of 50, 100, 200 and 400 J.kg"-"1; the limit dose was 500 J.kg"-"1. From the results obtained, a kinetic model was constructed of radiation phenol oxidation in aqueous solutions in the presence of various organic and inorganic additions. (B.S.).
A brain weight deficit of about 70 mg was induced at doses of approximately 75-mGy and a deficit of 60 mg was induced at 100 mGy. This confirms the effects projected and observed by Wanner and Edwards. Although the data do not demonstrate a clear dose-response relationship between the 75-mGy and 100-mGy groups, the data are statistically consistent with a dose-response effect because of the overlapping confidence intervals. The lack of a statistically significant observation is most likely related to the small difference in doses and the limited numbers of animals examined. There are several factors that can influence the brain weight of guinea pig pups, such as caging and housing conditions, the sex of the animal, and litter size. These should be taken into account for accurate analysis. Dam weight did not appear to have a significant effect. The confirmation of a micrencephalic effect induced x rays at doses of 75-mGy during this late ...
Estimations on the somatic and genetic effects of small doses of ionizing radiations in Man have been proposed by the Advisory Committee on the Biological Effects of Ionizing Radiation, set up by the U.S. National Academy of Sciences. They have been published in an important report, issued in 1972, from which we briefly analyze here the Chapter dealing with the somatic effects. Small doses of raditions are expected to promote only carcinogenic effects. After a rapid survey of the human experience on which the estimations are based, as regards the latent period of cancers, the plateau region (period of high risk) and the absolute and relative risk expressed per rem, per 10"6 persons, per year, for leukaemia (having the highest risk) and for the ''other cancers''. These estimations were obtained by linear extrapolation to the 1 rem level from observations made after irradiation at relatively high dose levels and much higher dose-rates. This ...
Shadow effect was used for investigating damage of uranium dioxide monocrystal. The dependence of shadow minimum parameters on fluence of "2"2Ne ions with 172 MeV energy was followed when detecting fission fragments. Ion doseresponsible for sufficient microdamage of lattice structure, included into the classification of heavy ion damage effect on monocrystals was determined. The problem of radiation intensity effect on the character of occurred damages was studied. It was established that macroscopic sample failure, caused by generation of considerable mechanical stresses in monocrystal under beam effect could be observed along with microdamages of lattice structure at ion flux density >10"1"2 cm"-"2Xs"-"1.
There is a continuing need to understand dose-response relationships for ionizing radiation in order to protect the health of the public and nuclear workers from undue exposures. However, relatively few human populations have been exposed to doses of radiation high enough to cause observable, long-term health effects from which to derive dose-response relationships. This is particularly true for internally deposited radionuclides, although much effort has been devoted to epidemiological studies of the few types of exposures available, including lung cancers in uranium miners form the inhalation of the radioactive decay products of Ra, liver cancers in patients injected with Thorotrast X-ray contrast medium containing Th, bone cancers in radium dial painters who ingested Ra, and bone cancers in patients who received therapeutic doses of Ra. These four types of exposures to internally deposited ...
This randomized, placebo-controlled, double blind, parallel dose-response study investigated the impact of 4-week commercial yoghurt consumption supplemented with Bifidobacterium animalis subsp. lactis (BB-12) and Lactobacillus acidophilus (LA-5) on fecal bacterial counts of healthy adults. Fifty-eight volunteers were randomly assigned to three different groups: 1. placebo (no probiotic, no starter and no green tea extract); 2. Yoptimal (10^9cfu/100g of BB-12 and LA-5 and 40mg of green tea extract) and 3. Yoptimal-10 (10^1^0cfu/100g of BB-12, 10^9cfu/100g of LA-5 and 40mg of green tea extract). These yoghurt products also contained Lactobacillus delbrueckii subsp. bulgaricus (10^7cfu/100g) and Streptococcus thermophilus (10^1^0cfu/100g). The quantitative PCR (qPCR) results showed that ther...
A human cholangiocarcinoma, Ch-1, serially transplanted to nude mice was used for experimental chemotherapy, radiotherapy, and conbination chemoradiotherapy. In the group of chemotherapy with single drug, Mitomycin C (MMC) revealed greater effectiveness than Adriamycin in terms of tumor regression, histological findings, and minor side effects. MMC and radiotherapy by Linac X-ray showed exponential linear doseresponse curve against tumor weight. Their effects were equivalent at doses of MMC 1 mg/kg and radiation 1,000 rads/mouse in the changes of tumor weight and of histological findings which were similar to each other. Combination chemoradiotherapy showed the synergistic action when the radiation (500 rads/mouse) was performed before MMC (0.5 mg/kg) administration, whereas only the additive effect was observed when the sequence was reversed. The cell kinetic analysis was performed by the impulse ...
Purpose: Understanding the kinetics of tumor growth∕shrinkage represents a critical step in quantitative assessment of therapeutics and realization of adaptive radiation therapy....Full Text Available
Mitotic delay is described as a classical response to radiation; however, circadian rhythmicity in cell division in vivo has not been considered by many authors. The present study investigated the relation between fluctuations reported as mitotic delay and recovery in vivo and circadian oscillations in mitotic index in mouse corneal epithelium. One aspect involved single doses (approximately 600 rad) given to mice at different circadian stages. The normal circadian rhythm in cell division was never obliterated. Inhibition of mitosis was evident but unpredictable, ranging from 6 to 15 hr after irradiation. Recovery was evident only during the daily increase in mitotic index of controls. The classical interpretation of recovery from mitotic delay may be in an in vitro phenomenon not reflecting in vivo responses, which are apparently strongly circadian stage dependent. The second portion of the study demonstrated a dose-response effect on length ...
The book examines current experimental and clinical knowledge concerning the biological and biophysical effects of electromagnetic radiation, particularly that in the microwave range. The biophysical bases of the interaction of electromagnetic radiation with matter are reviewed with emphasis on biological systems, and the effects of radiation on critical biological systems, including the nervous, reproductive, visual and blood-forming systems are compared. Data concerning the lethal effects of nonionizing radiation is presented and characteristics of the effects of electromagnetic radiation on the whole mammalian organisms are examined. Various reactions of the neuroendocrine system to electromagnetic radiation are described, with particular attention given to the adrenal system, and the combined effects of ionizing and microwave radiation ...
In recent years it has become evident from epidemiological and experimental data that a large number of environmental factors, including diet, play a role in modifying the incidence of cancer. Cell culture systems in which oncogenic transformation serves as an end point are powerful tools for evaluating these questions. Using such systems it has been shown recently that pyrolysis products from charred surfaces of broiled meat and fish can transform hamster embryo cells in vitro as well as produce tumors in the animal. Our studies in vitro have demonstrated the oncogenic potential of ionizing radiation in both hamster and human cells and have established in hamster cells the doseresponse relationship at doses ranging from 1 to 600 rad for x-rays and 0.1 to 150 rad for neutrons. The present work was aimed at evaluating whether there exists a cocarcinogenic interaction between a pyrolysis product and x-rays in their ability ...
We studied the dose-response effects of #gamma#-irradiation on the weight gains of the body and the brain in ICR mice exposed to various doses of "6"0Co #gamma#-irradiation ranging from 0 to 1.5 Gy on day 13 of pregnancy (E13). We found that 0.5 Gy #gamma#-irradiation caused a significant reduction in brain weight but not in body weight among 6-week-old mice. Higher doses (1.0, 1.5 Gy) seriously inhibited body and brain development, resulting in significantly low weights at 6 weeks of age. A significantly lower brain weight among fetuses exposed to 1.5 Gy was found as early as 24 hours after exposure, while significant reductions in the body weight of these same fetuses appeared 3 days after exposure. The effects of radiation on brain and body development were similar for both males and females. (author).
Methylisothiazolinone (MI) used alone is a new preservative causing a high prevalence of contact allergy. The eliciting threshold of MI is unknown. The combination of MI and phenoxyethanol enhances the antimicrobial efficacy of MI.
Full text: An adaptive response is a decreased biological effect induced by a priming radiation dose given prior to a challenge dose. Adaptive responses contradict the linear-nothreshold model of risk estimation. The pKZ1 mouse chromosomal inversion assay is an extremely sensitive assay for studying the mutagenic effect of low dose radiation. A non-linear doseresponse for chromosomal inversion has been observed in pKZ1 spleen and prostate after a single whole body irradiation with doses between 1?Gy and 10mGy. Doses between 5-10?Gy resulted in an induction in inversions and doses between 1-10mGy resulted in a reduction below endogenous inversion frequency. These results suggest that doses in the 1-10 mGy range cause host responses which overcompensate by not only preventing inversions that would normally occur as a result of the low doses of radiation but also by preventing some of ...
A Task Group of the International Commission on Radiological Protection (ICRP) has finished a report Biological Effects after Prenatal Irradiation (Embryo and Fetus) which has been approved by the Main Commission and Will be Published. Some new important scientific data shall be discussed in this contribution. During the preimplantation period lethality of the mammalian embryo is the dominating radiation effect. However, in mouse strains with genetic predispositions it has been shown that also malformations can be caused. This effect is genetically determined and its mechanisms is different from the induction of malformations during major organogenesis. Radiation exposures during this prenatal period leads ato an increase of genomic instability of cells in the normal appearing fetuses. These radiation effects can be transmitted to the next generation. A renewed analysis of individuals with severe mental retardation after ...
In areas where radiation dose monitoring has not been performed, it is essential to use material available in the environment be able to rapidly assess doses to individuals for immediate emergency medical care or for general estimation of the radiological consequences. It was shown that certain types of telephone cards containing microchips have the potential to be used as individual radiation dosimeters in emergency situations to detect doses over 250 mGy by luminescence measurements. In order to understand the dosimetric properties of chip cards, the components obtained from INFINIEON Company at various stages of production were used for luminescence measurements. It is found that the protecting layer used above the chips so called 'globe top' is the main source of radiation induced signal in chip cards. The globe top produced by INFINIEON at that stage is found to contain SiO2 and Epoxy. In order to improve the ...
The linear/supralinear behaviour of the TL doseresponse in LiF:Mg,Ti (TLD-100) and its dependence on ionisation density is a fairly unique phenomenon which cannot be explained by conventional atomic 'conduction band/valence band' kinetic models. The Track Interaction Model (TIM) provides the microscopic framework which, when coupled with other appropriate physical mechanisms (spatial localisation of traps and recombination centres, competing centres, variations in the capture cross sections with temperature, etc.) can be used to describe all the dominant features of the TL supralinearity of LiF:Mg,Ti and similar TL systems. The unique feature of the TIM applied to alpha particles is that it is an integral approach with only one free parameter, the average charge carrier migration distance in the luminescence recombination stage. Although the TIM provides a comprehensive description of the mechanisms underlying supralinearity ...
Ignoring the numerous, known and mainly unknown, interactions between chemicals and ionizing radiations, causes strong controversy about the risks of ionizing radiations. Yet the best known interactions between chemicals and radiations is that between radon and tobacco smoke. Although it is and it will be always impossible to derive quite quantitative laws for this interaction, it has been possible to derive some semi-quantitative relationships based on reasonable assumptions and statistics on lung cancer deaths in developed countries. They show that ignoring the dangers of tobacco smoking as we did still long after we had recognised the dangers of radiations, could asses to radiations thirty or forty times more risks than reality. As present world is flown by tens of thousands chemicals, little or not present in a natural environment, and ...
Quantitative ecological risk assessment (ERA) is a means whereby the risk posed by a toxicant in any system can be evaluated by comparing the distribution of its measured or modelled concentrations (water quality data (WQD)) with available information on the range of concentrations that are known to adversely affect biota within that, or similar, habitats (dose-response data (DRD)). Initially, the WQD are compared with regulatory criteria (e.g. ANZECC and ARMCANZ, 2000). If they fail this test, then, on the assumption that both data sets comprise subsets of the entire range of concentrations, probability density functions are derived assuming a standard distribution form a typically log-normal. In this paper, AQUARISK has been used to estimate the risk posed by copper in effluent from the Rum Jungle mine site, pre- and post-remediation, and the proportion of taxa likely to be affected in the East Branch (EB) of the Finniss River downstream of ...
Consensus principles from radiation biology were used to describe a generic set of nonlinear, first-order differential equations for modeling of toxicity-induced compensatory cell kinetics in terms of sublethal injury, repair, direct killing, killing of cells with unrepaired sublethal injury, and repopulation. This cellular model was linked to a probit model of hematopoietic mortality that describes death from infection and/or hemorrhage between {approximately} 5 and 30 days. Mortality data from 27 experiments with 851 doseresponse groups, in which doses were protracted by rate and/or fractionation, were used to simultaneously estimate all rate constants by maximum-likelihood methods. Data used represented 18,940 test animals distributed according to: (mice, 12,827); (rats, 2,925); (sheep, 1,676); (swine, 829); (dogs, 479); and (burros, 204). Although a long-term, repopulating hematopoietic stem cell is ancestral to all lineages needed to restore normal ...
In defining criteria for good protection against ionizing radiation, it is important to assess quantitatively the likely risk of any radiation exposure. The 'somatic' risks to the individual result mainly from induction of cancer in the organs irradiated, and these risks can now be estimated on the basis of numerous detailed epidemiological surveys of exposed human populations. Estimates of the risk of hereditary effects, from genetic changes induced in germ cells, are based largely on the frequency with which such effects are induced in other species. In both cases the risk at very low dose can be inferred using knowledge of the way in which radiation damage is caused in tissues. Coherent systems of radiation protection are based on a restriction of doses to the whole body and to individual organs, such that the induction of cancer and genetic harm is infrequent, and the threshold ...
There is increasing evidence that receptor-mediated events impact one or more stages responsible for tumor development in experimental animals and humans. Although many chemicals and endogenous hormones...Full Text Available
1. The effect of three single doses of nifedipine on exercise-induced asthma has been examined in 11 asthmatic subjects. 2. On four separate days patients undertook 6 min of exercise on a treadmill...Full Text Available
Experiments were conducted to determine the doseresponse of rat bladder urothelium to a range of different single and fractionated intravesicular doses of the carcinogen, N-methyl-N-nitrosourea (MNU)....Full Text Available
Although humans vary in their response to chemicals, comprehensive measures of susceptibility have generally not been incorporated into human risk assessment. The U.S. EPA dose-response-based risk assessments...Full Text Available
Alternatives for developing chronic exposure limits for noncancer effects of trichloroethylene (TCE) were evaluated. These alternatives were organized within a framework for dose-response assessment--exposure:dosimetry...Full Text Available
The dielectrophoretic (DEP) crossover method has been applied to the detection of cell responses to toxicants. Time and doseresponses of the human cultured leukemia (HL-60) line were measured...Full Text Available
The principle is described of X-ray fluorescence analysis and the manner of detecting the emitted characteristic radiation. The advantages are presented of radionuclide X-ray fluorescence analysis which consist primarily in the possibility of conducting a totally non-destructive analysis, and of accurate and relatively narrow localization of the analyzed area, the simultaneous qualitative and quantitative determinations of a large number of elements in the order of concentrations 10"1 to 10"-"4%, stability of excitation radiation flux, simple design and relatively low capital costs. The so-called matrix effect is pointed to. A number of examples is given of the use of the cited method, including its use in the analysis of art objects. (J.B.).
The long-term survival of certain patients after treatment with radiation or chemotherapeutic agents has allowed the realization that agents that effectively control cancer in the human subject may also possess an oncogenic potential, resulting in secondary malignancies in a significant proportion of surviving patients. A quantitative assessment of the oncogenic effects of these agents at a cellular level is important, as is information on conditions and agents that may effectively alter the development of the neoplastic state. Cell culture systems where the neoplastic transformation of cells can be scored after exposure to carcinogens offer powerful tools for evaluating the oncogenic potential of radiation and chemotherapeutic agents.
The hot uniform aluminium plasma was produced by irradiating thin aluminium dotted foil smoothly with the 9th 0.53 ?m laser on Shenguang II laser facility. The emitted spectrum was measured from the front and tangential direction of the target with two crystal spectrometers, and the quantitative spectrum from the front of the target was obtained. The state of laser- produced plasma was simulated with the radiation hydrodynamics code MULTI-1D, and the emitted spectrum was calculated with the spectrum code of Collision-Radiation model under the simulated plasma state. The experimental spectrum accords with the simulated one. (authors)
Geostatistical techniques make it possible to qualitatively and quantitatively analyze spatiotemporal inherent characteristics of environmental radiation or radioactivity. Spatial patterns and trend analysis of environmental radioactivity, e.g., {sup 137}Cs and {sup 40}K, in soil around nuclear facilities (Kori, Wolsung, Yeonggwang, Uljin, and Daejeon) will be investigated and discussed.
This paper identifies some of the issues which arise in the consideration of the derivation of new limits on exposure to internal emitters. Basic and secondary radiation protection limits are discussed. Terms are defined and applied to the limitation of risk from stochastic effects. Non-stochastic data for specific internal emitters (/sup 131/I and the radium isotopes) are presented. Emphasis is placed on the quantitative aspects of the limit setting problem. 65 references, 2 figures, 12 tables.
Based on a literature study an actual summary of the risk-utility problems in X-ray diagnosis is outlined due to the Recommendations of the International Commission for Radiation Protection (ICRP publication 26/1977). Papers demonstrating quantitative assessment of the somatic and genetical risk in X-ray examination are preferably cited and evaluated. It is concluded that the somatic and genetical risk is low in diagnostic ratiology. However, it must not be neglected and has always to be compared to the utility of an examination as well as to other risks of the examination. (author).
The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional ...
The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional ...
The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional ...
In situ X-Ray microtomography offers new opportunities for analysing sintering mechanisms since it allows 3D observation of the microstructural evolution of the powder all along a sintering cycle. With synchrotron radiation at ESRF, a 3D image with a resolution of 2 {mu}m can be obtained in about one minute. In addition to the visual examination of the images, relevant microstructural parameters can be measured through quantitative image analysis using recently developed tools. In this paper the results obtained with two materials, loose copper powder and compacted steel powder, are resumed. For copper powder, the dispersion of local parameters such as particle co-ordination number and porosity is investigated. Concerning steel compacts, data about pore morphology evolution and on local strains provides clues for understanding the anisotropic shrinkage of such compacts. (authors)
A Quantitative Computed Tomography (QCT) method, simplifying the well-known technique proposed by Genant (1982) and applied to a standard third generation whole body CT scanner is described. This technique was applied in the measurement of the trabecular bone which has high sensitivity for metabolic changes. The BMC (Bone Mineral Content) measured in different groups of subjects (healthy postmenopausal patients versus women with postmenopausal osteoporosis) showed a highly significant difference (p<0.001). The precision of repositioning (coefficient of variation 1.8% to 2.3%, obtained in healty male patients) and the good, linear relationship computed from the phantom values, minimize measurement errors. Since this method is quickly applied and involves low-dose radiation-exposure, it could be introduced in the clinical study of metabolic bone diseases.
Endothelial dysfunction and increased platelet aggregation may be involved in the pathogenesis of normal tissue radiation toxicity. This study assessed clopidogrel, an inhibitor of ADP-induced platelet aggregation, as a modulator of intestinal radiation injury (radiation enteropathy). Rat small intestine was exposed to 21 Gy X-radiation. Clopidogrel (20 mg/kg/day) or vehicle was administered from 2 days before to 10 days after irradiation. Structural radiation injury, neutrophil infiltration, smooth muscle cell proliferation, collagen content, and TGF-beta1 expression were assessed 2 weeks (early phase) and 26 weeks (delayed phase) after irradiation, using quantitative histology and immunohistochemistry, morphometry, and real-time fluorogenic probe RT-PCR. Irradiated intestine exhibited significant histopathologic injury, reduced mucosal surface area, vascular ...
In view of no satisfactory mathematical model is presently available for the dose-response curve of immunoradiometric assay, a three parameter model based on single binding site mass action law has been derived. A curve fitting method based on similar principle of linear robust regression was designed and a software was prepared for use on IBM personal computers. Experiments revealed that the model is applicable to a variety of IRMA systems as well as to time-resolved immunofluorometric assay of hAFP. When there was outlier(s) of the calibration curve, the average bias of unknown samples obtained with this method is significantly smaller than methods using four parameter logistic model or four parameter single site mass action model.
Endothelial dysfunction is involved in radiation responses in many normal tissues, including intestine. Endothelium-directed interventions ameliorate intestinal radiation injury (radiation enteropathy) in animal models, and anecdotal reports also suggest a beneficial effect of heparin. This study assessed low molecular weight heparin as an intestinal radiation response modifier. Rats underwent localized small bowel irradiation. Groups of rats were treated with saline, nadroparin (3 mg/kg/d), or a non-anticoagulant heparin (SR80258, 3 mg/kg/d), from 3 days before to 2 weeks after irradiation. The intestinal radiation response was assessed 2 weeks and 6 weeks after irradiation using quantitative histology; morphometry, and cellular and molecular end-points. Compared to vehicle-treated controls, nadroparin significantly exacerbated structural ...
Leachability of neutron irradiated fly ash is investigated as a method for studying element leaching properties of this material with various leaching media. Quantitative aspects of radiation damage are shown to be minor. Therefore, the technique should be applicable for this purpose. It is further shown that this technique affords significant advantages over the conventional post-leaching analysis with respect to utilization of natural solutions for the investigation of fly ash leachability. However, for a few elements such as Pb, Bi, V, and Al, the various nuclear parameters involved invalidate applicability of the present technique.
Leachability of neutron irradiated fly ash is investigated as a method for studying element leaching properties of this material with various leaching media. Quantitative aspects of radiation damage are shown to be minor. Therefore, the technique should be applicable for this purpose. It is further shown that this technique affords significant advantages over the conventional post-leaching analysis with respect to utilization of natural solutions for the investigation of fly ash leachability. However, for a few elements such as Pb, Bi, V, and Al, the various nuclear parameters involved invalidate applicability of the present technique.
This paper analyses the errors caused by interpolation from existing cases for assessing indoor air flow, air quality and thermal comfort in an office. A sensitivity study is then provided to determine the influence of several boundary conditions on indoor air diffusion. The research is conducted numerically by using a low-Reynolds-number k-{epsilon} model. It can be concluded that the interpolation errors caused by the variations of solar radiation, window size, heat source location due to lighting, and the surface temperatures of interior walls are small and can be quantitatively determined. But it is difficult to estimate the errors introduced by the variations of furniture location and size. (author).
There are clearly identified scientific requirements for continuous profiling of atmospheric water vapor at the Department of Energy, Atmospheric Radiation Measurement program, Southern Great Plains CART (Cloud and Radiation Testbed) site in northern Oklahoma. Research conducted at several laboratories has demonstrated the suitability of Raman lidar for providing measurements that are an excellent match to those requirements. We have developed and installed a ruggedized Raman lidar system that resides permanently at the CART site, and that is computer automated to eliminate the requirements for operator interaction. In addition to the design goal of profiling water vapor through most of the troposphere during nighttime and through the boundary layer during daytime, the lidar provides quantitative characterizations of aerosols and clouds, including depolarization measurements for particle phase studies.
The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.
The activity of tyrosine aminotransferase (TAT) in the liver of mice subjected simultaneously to ionizing radiation and to local inflammatory process showed in the first 24 hours of the experiment statistically significant changes resulting from summation of the harmful effects of both factors. In the second 24-hour period an evident tendency was observed for return of a normal circadian rhythm of the enzyme. This points to presence of an endogenous mechanism of suppression of the manifestations of significant desynchronization of the circadian rhythm. The paper contains also a trial of mathematical analysis of changes in TAT activity in the circadian rhythm, a description and analysis or the suppression process, qualitative and quantitative determination of the phenomenon of cumulation of the effects of powerful stress factors acting on the animal organism. The obtained results were compared with the results of investigations of TAT activity ...
The project is focusing on the formation and growth mechanisms of atmospheric aerosol and cloud droplets. Both aerosol particles and cloud droplets affect strongly on the atmospheric radiation fluxes by scattering and absorption. The droplet formation results from physical and chemical processes occurring simultaneously. The studies concerning the tropospheric cloud droplet formation, laboratory experiments with a cloud chamber and stratospheric cloud formation are summarized. The recent studies summarized in this presentation indicate that both aerosol particles and cloud droplets have a significant role in climatic change and ozone depletion problems. The anthropogenic emissions of gaseous and particulate pollutants change the properties of atmospheric aerosols and cloud droplets. The research in this field will be continued and more quantitative understanding based both experimental and theoretical studies is required
The dose distribution in a Rando phantom has been measured for typical EMI 5005 CT scans of the head, chest, abdomen and pelvis. These dose distributions have been used to generate quantitative estimates of the somatic and genetic radiation risks associated with these CT examinations and also to measure the total energy imparted during each scan. A comparison has been made between the radiation risk estimates and the energy imparted measurements. The energy imparted measurements are not a good indicator of the somatic and/or genetic risks when one type of CT scan is compared with another. However, for a given type of scan, the energy imparted may be a reasonable indicator of the relative somatic risks associated with different CT examinations. Considerable care should be taken when interpreting and using any measured value of energy imparted in a radiological examination since published values of the risk per unit energy ...
In order to evaluate the effects of radioactivity on active vegetal substances, samples of Fennel (Foeniculum vulgare Miller., fructus), Guarana (Paulinia cupana, Kunth, semen), Gingko (gingko biloba, L., folium), and Kawa-Kawa (Piper methysticum G. Forst, rhizoma), were treated with scaling doses (0 to 25 KGy) of gamma radiation (Co{sup 60}). The 'blind test' methodology was used. The active substances from each sample were analysed by qualitative and quantitative methods after radiation. There were no significant differences seen between the control sample (0 KGy) and the irradiated samples. Microbe contamination was significantly reduced, about 10000 CFU/g, with the initial 5 KGy dose. It was concluded that gamma radiation can be used as an alternative procedure to reduce microbiologic contamination in medicinal plants. Before this procedure can be extended to other medicinal ...
Analytical expressions for thermoluminescence (TL) dating based on the modified Zimmerman model were derived. The non-linear behaviour of TL sensitivity is reexamined and is found to be due to electron capturing competitions in both test-dose excitation and the readout stages. A curve fitting method is proposed to determine the paleodose for the additive dose dating method. The multiple activation technique is also investigated, from which the paleodose should be regarded as an upper limit.
Analytical expressions for thermoluminescence (TL) dating based on the modified Zimmerman model were derived. The non-linear behaviour of TL sensitivity is reexamined and is found to be due to electron capturing competitions in both test-dose excitation and the readout stages. A curve fitting method is proposed to determine the paleodose for the additive dose dating method. The multiple activation technique is also investigated, from which the paleodose should be regarded as an upper limit.
A technique for quantitative determination of cephalothin and desacetylcephalothin in serum using a method based on high-pressure liquid chromatography is described. Both compounds were quantitatively...Full Text Available
A 'Laboratory of Quantitative Methods in Monument Research' is being built at the CTU Prague. Its primary orientation is the investigation of historic architecture, although other objects of art can also be investigated. In the first phase, two radiation methods are being established, but it is set up in such a way, that various other methods can readily be added in its future development. The radiation methods chosen for the initial development of the laboratory are: thermoluminescence dating and X-ray fluorescence analysis. The design of the automated TL-reader, built in our laboratories, is adjusted for the purpose of dating of historic brick architecture (which, of course, does not exclude applications for ceramics and other materials). The investigation of renaissance architecture in southern Bohemia and Moravia is under preparation as the first large campaign of this kind in the Czech Republic. ...
A 'Laboratory of Quantitative Methods in Monument Research' is being built at the CTU Prague. Its primary orientation is the investigation of historic architecture, although other objects of art can also be investigated. In the first phase, two radiation methods are being established, but it is set up in such a way, that various other methods can readily be added in its future development. The radiation methods chosen for the initial development of the laboratory are: thermoluminescence dating and X-ray fluorescence analysis. The design of the automated TL-reader, built in our laboratories, is adjusted for the purpose of dating of historic brick architecture (which, of course, does not exclude applications for ceramics and other materials). The investigation of renaissance architecture in southern Bohemia and Moravia is under preparation as the first large campaign of this kind in the Czech Republic. Radionuclide X-ray ...
Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two detectors, respectively and the imaging quality of phantoms. ...
Plutonium metal is produced by reducing PuF{sub 4} prepared from PuO{sub 2} by fluorination. Both fluorination and reduction are batch processes at the Los Alamos Plutonium Facility. The conversion of plutonium oxide to fluoride greatly increases the neutron yield, a result of the high cross section for alpha-neutron ({alpha},n) reactions on fluorine targets compared to the (more than 100 times) smaller {alpha},n yield on oxygen targets. Because of the increase, total neutron counting can be used to monitor the conversion process. This monitoring ability can lead to an improved metal product, reduced scrap for recycle, waste reduction, minimized reagent usage, and reduce personnel radiation exposures. A new stirred-bed fluorination process has been developed simultaneously with a recent evaluation of an automated neutron-counting instrument for quantitative process monitoring. Neutrons are counted with polyethylene-moderated {sup 3}He-gas ...
The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal equilibrium, homogeneous ...
The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal equilibrium, homogeneous ...
The overall objective of this project has been to develop immunochemical methods to quantitate unique DNA base damages in order to facilitate studies on radiation-induced damage production and repair. Specifically, we have been using antibodies raised to damaged bases to quantitate unique lesions in model systems in order to evaluate their potential biological consequences. Our approach has been to synthesize modified nucleotides or nucleosides, conjugate them to protein carriers, and use the conjugates as immunogens in rabbits or to prepare monoclonal antibodies. We have been studying damages that are stable radiolysis products found in X-irradiated DNA and thus of potential biological consequence. Our aim is to build an in vitro and in vivo data base on the interactions between model DNA lesions and such cellular enzymes as DNA polymerases and repair endonucleases. Initial studies have focused on pyrimidine ring ...
The overall objective of this project has been to develop immunochemical methods to quantitate unique DNA base damages in order to facilitate studies on radiation-induced damage production and repair. Specifically, we have been using antibodies raised to damaged bases to quantitate unique lesions in model systems in order to evaluate their potential biological consequences. Our approach has been to synthesize modified nucleotides or nucleosides, conjugate them to protein carriers, and use the conjugates as immunogens in rabbits or to prepare monoclonal antibodies. We have been studying damages that are stable radiolysis products found in X-irradiated DNA and thus of potential biological consequence. Our aim is to build an in vitro and in vivo data base on the interactions between model DNA lesions and such cellular enzymes as DNA polymerases and repair endonucleases. Initial studies have focused on pyrimidine ring ...
Purpose/Objective: The role of programmed cell death (apoptosis) as a cellular response to cancer therapy such as radiation or chemotherapy is the subject of much study, and manipulation of the apoptotic response in tumor cells may be valuable in the treatment of a variety of cancers. Both p53 dependent and independent apoptotic pathways have been identified; p53 is mutated in at least 50 % of human cancers and a majority of radiation resistant tumors contain p53 mutations. This study is designed to examine the induction of programmed cell death in a human colon carcinoma cell line that possesses two mutated p53 alleles. Ionizing radiation alone, or in combination with the chemotherapeutic drug 5-fluorouracil (5-FU), were used to elicit the apoptotic response. This study will focus on whether these treatments can induce a significant apoptotic response in cells that have mutated p53 alleles. Materials and Methods: HT-29 ...
The suggestion has often been made that an additional radiation exposure imposed on humanity as a result of some important activity such as electricity generation would be acceptable if the exposure was 'small' compared to the natural background. In order to make this concept quantitative and objective, we propose that 'small compared with the natural background' be interpreted as the standard deviation (weighted with the exposed population) of the natural background. We believe that this use of the variation in natural background radiation is less arbitrary and requires fewer unfounded assumptions than some current approaches to standard-setting. The standard deviation is an easily calculated statistic that is small compared with the mean value for natural exposures of populations. It is an objectively determined quantity and its significance is generally understood. Its determination does not omit any of the pertinent ...
Low resolution visual polarimetric photographic imagery of the Galveston Bay oil spill from a tanker accident on July 28, 1990 was obtained and analyzed. The low resolution imagery (30 to 100 meters) was obtained concurrently with high resolution (1 meter), and is representative of what would be seen by a polarimetric satellite. Orthogonal red-green-blue (RGB) polarimetric images obtained with color photography were digitized by KODALUX on to a CD ROM. These polarimetric images were then used to calculate the percent polarization. The positive and negative percent polarized radiation scattered by each of the sea surface waves is seen individually in high resolution imagery. (Percent polarization is defined as positive when the dominant radiation is perpendicular to the plane of incidence and negative when it is parallel). The analysis of low resolution polarimetry is approached in a different manner than high resolution; in high resolution, ...
The most important factor in assessing radiologic risk is ensuring scientific means for evaluation of the radioactive release impact upon humans and organisms. To evaluate quantitatively this impact not only knowledge of radioactivity distribution in these dynamical systems is necessary but also understanding the transfer mechanisms between ecosystem components is needed. Thus a complete radioecologic study appear to be very complex and needs defining the source term, dynamic description of radionuclides behavior in the ecosystem, estimation of radiation doses in the major components of the ecosystem and finally the effects of radiation doses upon different parts of the systems. A diagram of the steps implied in evaluation of the effects due to radioactive effluent release in the environment is presented and discussed. The following steps are described: - identification of radioactive sources, as well as their input rate. ...
An attempt was made for early quantitative assessment of the severety of an injury, using the nuclear acids (NA) content as a biochemical indicator. Sexually mature male rats with body mass 160-180 g were irradiated with doses 0.5, 1, 2, 4 and 8 Gy of "1"3"7Cs source. Uneven irradiation was achieved by shielding the abdominal-lumbar area with lead rings, measuring 2,5/50 mm. A 28-30% fall of the dose beneath the shielded zone was thus provided. Dose-dependent quantitative changes in Na content were determined on hours 24 and 72 within the range from 0.5 to 8 Gy and followed up until day 30 after irradiation with nonlethal (2 Gy) and lethal (8 Gy) doses. The total NA content in the leucocytes was determined by the method of Kritski and Aleksandrov. The uneven irradiation of rats within the 0,5-8 Gy range induced early dose-dependent changes in NA content. The nature of their post-irradiation dynamics also depended on the ...
Laboratory dose-response experiments with organophosphate and pyrethroid pesticides, and dose-response experiments with increasing particle loads were used to determine which of these stressors were likely responsible for the toxicity and macroinvertebrate impacts previously observed in the Salinas River. Experiments were conducted with the amphipod Hyalella azteca, the baetid mayfly Procloeon sp., and the midge Chironomus dilutus (Shobanov, formerly Chironomus tentans). The results indicate the primary stressor impacting H. azteca was pesticides, including chlorpyrifos and permethrin. The mayfly Procloeon sp. was sensitive to chlorpyrifos and permethrin within the range of concentrations of these pesticides measured in the river. Chironomus dilutus were sensitive to chlorpyrifos within the ranges of concentrations measured in the river. None of the species tested were affected by turbidity as high as 1000 NTUs. The current study shows that ...
Anomalous fading of the feldspar infrared stimulated luminescence (IRSL) signal hampers possibilities of using feldspar IRSL to obtain burial ages for sediments beyond the dating range of quartz optically stimulated luminescence. Here, we propose a new approach to quantify anomalous fading of the feldspar IRSL signal over geological burial times based on laboratory fading experiments. The approach builds on the description of the quantum mechanical tunnelling process recently proposed by Huntley [2006. An explanation of the power-law decay of luminescence. J. Phys. Condensed Matter 18, 1359-1365]. We show that our methods allow the construction of un-faded and natural IRSL dose-response curves as well as anomalous fading rates in field saturation. The predicted level of field saturation closely approximates the measured saturation level for five samples from fluvial deposits (Lower Rhine) known to be older than 1 Ma. The modelled anomalous fading rate in field ...
This study is an attempt to measure the quantities of elements in a composite by irradiating that composite with #gamma#-rays of various energies and detecting the transmitted radiation through the composite. A previous knowledge of the number of the elements and their attenuation coefficients is required. The quantities are calculated by solving the matrix of a linear system of equations. A computer program was developed to select the best combinations of the available energies. Five criteria were established to determine these energy combinations: (i) the determinant of the attenuation coefficient matrix; (ii) the condition number, (iii) the number of times the solution of the matrix leads to acceptable results; (iv) the indicator, (a new concept); (v) the standard deviations of the results. The intended application of this technique in medicine is to measure the bone mineral content of the skeleton. An examination of the error propagation, the application of ...
As thin films become increasingly popular (for solar cells, LEDs, microelectronics, batteries), quantitative morphological information is needed to predict and optimize the film's electronic, optical and mechanical properties. This quantification can be obtained quickly and easily with X-ray diffraction using an area detector and synchrotron radiation in two simple geometries. In this paper, we describe a methodology for constructing complete pole figures for thin films with fiber texture (isotropic in-plane orientation). We demonstrate this technique on semicrystalline polymer films, self-assembled nanoparticle semiconductor films, and randomly-packed metallic nanoparticle films. This method can be immediately implemented to help understand the relationship between film processing and microstructure, enabling the development of better and less expensive electronic and optoelectronic devices.
The radionuclide X-ray fluorescence analyzer consists of a source changer and a sample changer. "5"5Fe, "1"0"9Cd and "2"4"1Am are used as excitation sources. The radiation is detected with a semiconductor Si(Li) detector. The complete assembly of the apparatus consists of an imagine unit, a keyboard, a floppy disc drive, a printer, a console and a rack with analog and digital electronics. Its multichannel amplitude analyzer consists of power supplies, a high voltage supply, a linear amplifier, an analog-to-digital converter and a computer. The technical specifications are given. The control and data processing system is controlled with an MHB 8080A microprocessor. Software for semiconductor gamma spectrometry and for quantitative gamma spectrometry will be supplied with the equipment. (E.S.). 3 figs., 4 refs.
Depletion of stratospheric ozone increases irradiance of terrestrial ultraviolet (UV) radiation at short wavelengths, which may be harmful to the human health. To understand quantitatively the risks caused by increasing UV radiation to the Finnish population, the actual UV exposure of the population has to be assessed. It was shown that the snow reflection increases the UV exposure to the face and eyes particularly in the northern Finland. In 1993 exceptionally low ozone levels persisted up to the end of May, which resulted in a theoretical increase in the annual UV dose ranging from 8 % to 13 % in Finland. The maximal increase in the measured erythemally effective dose rate was 34 % on 23 April, when compared with the theoretical normal value. During this study exposure models have been developed. The models have been combined them with Green`s radiation transfer model to estimate annual facial UV ...
We propose to investigate the spontaneous emission of radiation arising out of the interaction of a relativistic electron beam with a metallic grating (the Smith-Purcell effect). The work will concentrate, primarily, in the 50-120 #mu#m part of the infrared spectrum and will be an extension of the work begun by the Oxford-Dartmouth-Essex collaboration; one of the early objectives of the project will be to develop a quantitative understanding of the power spectrum of the emitted radiation over a wide range of emission angles. In particular, the limits of relativistic peaking of forward directed emission will be investigated. The electron beam will be produced by laser irradiation of a metallic cathode in the terminal of a small Van de Graff accelerator located in the Technische Universitaet, Muenchen. Beam energies will be in the range of 2 - 4 MeV. Initial tests on photoproduction of electrons have yielded 10 mA pulses with ...
E-35 reported the specific air flow analysis program using a CFSV model (including a human body model) to develop a high-accuracy evaluation simulator for heterogeneous thermal environment based on human thermal physiological conditions. E-36 reported development of the radiation heat transfer analysis module by using a numerical integral method to calculate shape factors. Radiation heat transfer characteristics every body part were clarified quantitatively by this module. E-37 reported the results on continuous measurement of physiological conditions and thermal environment factors every monitor under controlled indoor thermal environment, to collect measurement data necessary for improving the accuracy of a prediction program for human body temperatures. E-38 reported the study result on physiological reaction and subjective evaluation through an examinee experiment in a blood controlled region, to collect basic data for ...
The devised radionuclide analyzer for the determination of total sulfur in coal includes two radionuclide sources with different energies, which are accommodated in collimators fitted with adjustable diaphramgs. The sample compartment is located between the two sources. Moreover, an X-ray fluorescence standard can be slid into the sample compartment. A proportional detector for X-ray fluorescence and scattered gamma radiation is located off the sample compartment. The input of the proportional detector is interfaced to the output of a high-voltage supply, the output, to the information input of a control-and-evaluation unit. One of the control outputs of the control-and-evaluation unit is connected to the input of the sliding mechanism for the X-ray fluorescence standard. This arrangement enables automatic energy calibration of the analyzer. The analyzer can measure not only total sulfur in coal by radionuclide X-ray fluorescence analysis but also ash in coal by ...
The three mammalian transforming growth factor (TGF)-? isoforms (TGF-?1, TGF-?2, and TGF-?3) differ in their putative roles in radiation-induced fibrosis in intestine and other organs. Furthermore, tissue specificity of TGF-? action may result from temporal or spatial changes in production and/or activation. The present study examined shifts in the cell types expressing TGF-? mRNA relative to TGF-? immunoreactivity and histopathological injury during radiation enteropathy development. A 4-cm loop of rat small intestine was locally exposed to 0, 12, or 21-Gy single doses of x-irradiation. Sham-irradiated and irradiated intestine were procured 2 and 26 weeks after irradiation. Cells expressing the TGF-?1, TGF-?2, or TGF-?3 transcripts were identified by in situ hybridization with digoxigenin-labeled riboprobes. Intestinal wall TGF-? immunoreactivity was measured using computerized image analysis, and structural radiation ...
The purified integral membrane protein, band 3, from human erythrocytes was inserted into egg lecithin liposomes. The insertion of band 3 was determined from thermal transition data from the analysis of the C-H stretching region bands recorded at temperatures from 25 to -22[sup o]C. Raman spectra show that band 3 considerably broadens and lowers the thermal transition of egg lecithin liposomes, suggesting the insertion of band 3. The band 3-inserted liposomes were irradiated with gamma-rays (40 Gy) and the radiation target groups were determined by the analysis of the structural sensitive Raman bands in the 1600-1700 cm[sup -1] (amide I), 1200-1300 cm[sup -1] (amide III) and 550-1030 cm[sup -1] (side chain amino groups) regions. The radiation-sensitive groups as identified from Raman spectra in the region 550-1030 cm[sup -1] are tyrosines and cysteines. The radiation-induced changes in the secondary structure were ...
The purified integral membrane protein, band 3, from human erythrocytes was inserted into egg lecithin liposomes. The insertion of band 3 was determined from thermal transition data from the analysis of the C-H stretching region bands recorded at temperatures from 25 to -22"oC. Raman spectra show that band 3 considerably broadens and lowers the thermal transition of egg lecithin liposomes, suggesting the insertion of band 3. The band 3-inserted liposomes were irradiated with gamma-rays (40 Gy) and the radiation target groups were determined by the analysis of the structural sensitive Raman bands in the 1600-1700 cm"-"1 (amide I), 1200-1300 cm"-"1 (amide III) and 550-1030 cm"-"1 (side chain amino groups) regions. The radiation-sensitive groups as identified from Raman spectra in the region 550-1030 cm"-"1 are tyrosines and cysteines. The radiation-induced changes in the secondary structure were determined from amide I and ...
The evaluation of biological markers is recognized as necessary to the future of toxicology, epidemiology, and quantitative risk assessment. For biological markers to become widely accepted, their validity...Full Text Available
Quantitative microscopy has been extensively used in biomedical research and has provided significant insights into structure and dynamics at the cell and tissue level. The entire procedure...Full Text Available
Purpose/Objective: At present, treatment verification between portal and reference images is performed based on manually-identified features by radiation oncologist, which is both time-consuming and potentially error-prone. There is a demand for the computerized verification procedure in clinical application. The purpose of this study is to develop a computerized portal verification scheme for pelvic treatment fields. Materials/Methods: The automated verification system involves image acquisition, image feature extraction, feature matching between reference and portal images and quantitative evaluation of patient setup. Electronic portal images with a matrix size of 256 x 256 and 12 bit gray levels were acquired using a liquid matrix electronic portal imaging device. Simulation images were acquired by digitizing simulation films using a TV camera into images with 256 x 256 matrix and 8 bit gray levels. Initially a Canny edge detector is applied ...
Radiation exposure of members of the public can be increased appreciably by the use of building materials containing above-normal levels of natural radioactivity. This phenomenon has attracted attention in recent years, and in this review, an attempt is made to the quantify exposures incurred under various circumstances. The second section of the review is a general survey of those building materials, mostly industrial wastes, that have aroused interest in Member countries. The probability that environmental pressures may cause such wastes to be used more and more by building industries may lead to similar situations in the future. Other review material of a relevant nature is described in the third section. Primordial radionuclides only are considered here. They are: potassium-40 (K-40); radium-226 (Ra-226) and its decay products; the series headed by thorium-232 (Th-232). The important radiological consequences of the natural radioactivity in building materials ...
An assessment was undertaken of the risk of liver cancer in the USA associated with aflatoxin ingestion from peanuts. Both laboratory-animal data and epidemiological data collected from the scientific literature and several prominent mathematical extrapolation techniques were used. Risk estimates differed by a factor of greater than 1000 when the extrapolated results of three selected animal studies were analysed. Dose-response data for the male Fischer rat, the most sensitive mammalian species studied, produced an estimate of 158 cases of liver cancer per year in the USA at current levels of aflatoxin exposure. An estimate of 58 annual cases was predicted on the basis of epidemiological data of populations in Africa and Thailand.
The production of retrograde amnesia (RA) upon electron-beam exposure was investigated. RA production was evaluated using a single-trial avoidance task for 10, 1, and 0.1 microsecond pulsed exposures. The dose-response curve obtained at each pulse duration showed significant RA production. The most effective dose range was 0.1-10 rad at a dose rate of 1,000,000 rad/sec. By employing a 10 rad (1,000,000 rad/s) pulse, a memory loss of the events occurring in the previous 4 sec was demonstrated. The conclusion was that the RA effect might be due to sensory system activation which provided a novel stimulus that masked previous stimuli.
Coumarin (1,2-benzopyrone) is occurring in food, and is also used in cosmetics. In order to perform a risk assessment for both oral and dermal exposure, we applied a physiologically based approach to model kinetics in humans by simulating both routes of exposure. The concentration-time profile in liver revealed a higher peak concentration (Cmax-hep) for the oral when compared to the dermal route. The area under the concentration-time curve in the liver (AUChep) was found the same for both routes if the same extent of absorption is assumed. Doseresponse information from published rat studies were used to identify the metric relevant for liver toxicity. Liver exposure levels resulting from doses and durations as outlined in the studies were simulated in a rat model. We obtained 31 data pair...
To test whether the dose addition and independent action models can predict the combined toxicity of the mixtures of phenol and aniline derivatives, six phenolic and two aniline derivatives were selected as the test components. The inhibition toxicity of the derivatives and their mixtures to Vibrio qinghaiensis sp.-Q67 indicated that all dose?response relationships could be effectively described by the Weibull function with correlation coefficients greater than 0.99. The combined toxicity of two equivalent-effect concentration ratio mixtures and eight uniform design concentration ratio mixtures could be predicted successfully by the dose addition model within 95% confidence intervals. However, it was also well predicted by the independent action model, especially at lower concentrations.
Aims The aim of this study is to examine the dose?response relationships between age, ?lifestyle factors?? (body mass index, tobacco smoking, sports), and symptomatic knee osteoarthritis in a population-based case?control study. Additionally, the study aims to investigate the mode of interaction between body mass index (BMI) and physical workload (occupational kneeling/squatting and lifting/carrying of loads) with respect to the risk of symptomatic knee osteoarthritis. Methods In five orthopedic clinics and five practices, 295 male patients aged 25?70 with radiographically confirmed knee osteoarthritis associated with chronic complaints were recruited. The control group comprised 327 male control subjects. In a structured personal interview, body weight at different ages, body height, cumu...
Alpha continuous air monitors (CAMs) will be used at the Waste Isolation Pilot Plant (WIPP) to measure airborne transuranic radioactivity that might be present in air exhaust or in work-place areas. WIPP CAMs are important to health and safety because they are used to alert workers to airborne radioactivity, to actuate air-effluent filtration systems, and to detect airborne radioactivity so that the radioactivity can be confined in a limited area. In 1993, the Environmental Evaluation Group (EEG) reported that CAM operational performance was affected by salt aerosol, and subsequently, the WIPP CAM design and usage were modified. In this report, operational data and current theories on aerosol collection were reviewed to determine CAM quantitative performance limitations. Since 1993, the overall CAM performance appears to have improved, but anomalous alpha spectra are present when sampling-filter salt deposits are at normal to high levels. This report shows that ...
Human beings are confronted with another grievous disaster - coal fire. The monitoring on underground coal bed combustion relied on drilling supervising in the past, but this method is not good. By taking the coal fire of Gulaben mine in Inner Mongolia Autonomous Region as an example, the monitoring methods of underground coal bed combustion were explored based on the hyperspectra and high-resolution remote sensing technology. By employing the OMIS imaging apparatus developed by Shanghai Institute of Technical Physics of Chinese Academy of Sciences, the airborne hyperspectral images and the characteristic spectra of different types were obtained and the temperature was measured synchronously on the ground. Then according to the correlation of DN value of the thermal infrared band and surface temperature, the image information was processed, the spectral features were analyzed, and the surface temperature retrieval model was built. Finally, by hyperspectral imagery ...
Geological, geophysical, thermal, petrophysical and hydrological data available for the East Mesa hydrothermal system that are pertinent to the construction of a computer model of the natural flow of heat and fluid mass within the system are assembled and correlated. A conceptual model of the full system is developed and a subregion selected for quantitative modeling. By invoking the Boussinesq approximation, valid for describing the natural flow of heat and mass in a liquid hydrothermal system, it is found practical to carry computer simulations far enough in time to ensure that steady-state conditions are obtained. Initial calculations for an axisymmetric model approximating the system demonstrate that the vertical formation permeability of the deep East Mesa system must be very low (k/sub v/ approx. 0.25 to 0.5 md). Since subsurface temperature and surface heat flow data exhibit major deviations from the axisymmetric approximation, exploratory three-dimensional ...
The newly developed techniques by the Hot Laboratory (JMTR HL) have provided for us the key information on behavior of specimens due to mechanical / physical / chemical / synergistic effects of radiation, stress and water for fission and fusion reactor environment. These techniques are focused on several topics as follows; (1) miniaturized specimen test for the development of fusion reactor materials, (2) slow strain rate tensile testing (SSRT) and crack propagation measuring tests for the study of Irradiation Assisted Stress Corrosion Cracking (IASCC) of core internals of LWR, (3) handling technique on specimens including tritium for the research and development of tritium breeders and neutron multiplier as fusion blanket materials, (4) joining method using the Tungsten Inert Gas (TIG) welding technique for re-assembling of capsule and re-fabrication of specimen and (5) nondestructive evaluation using ultrasonic wave and infrared thermography for the ...
Dose-response studies of the radiosensitivity of spermatogonial stem cells in various epithelial stages after irradiation with graded doses of fission neutrons of 1 MeV mean energy were carried out in the Cpb-N mouse. These studies on the stem cell population in stages IX-XI yielded simple exponential lines characterized by an average D0 value of 0.76 +/- 0.02 Gy. In the subsequent epithelial stages XII-III, a significantly lower D0 value of 0.55 +/- 0.02 Gy was found. In contrast to the curves obtained for stem cells in stages IX-III, the curves obtained in stages IV-VIII indicated the presence of a mixture of radioresistant and radiosensitive stem cells. In stage VII, almost no radioresistant stem cells appeared to be present and a D0 value for the radiosensitive stem cells of 0.22 +/- 0.01 Gy was derived. Previously, data were obtained on the size of colonies (in number of spermatogonia) derived from surviving stem cells. Combining these data with data from the ...
The regional impacts of ozone on corn, wheat, soybean, and peanut crops are estimated by using dose-response functions to relate ambient maximum 7 h/d seasonal ozone concentrations to crop productivity data. Linear dose-response functions were developed from open-top field chamber studies. It was assumed that the limited number of cultivars and growing conditions available for the analysis were representative of major agricultural regions. Hourly ozone data were selected to represent rural concentrations and used to calculate maximum 7-h/d average values. Seasonal ozone averages for counties were extrapolated from approximately 300 monitoring sites. Results must be interpreted with knowledge of these assumptions and sources of uncertainty. Impacts are calculated for county units for the conterminous United States with maps showing patterns and tables summarizing the potential magnitude of ozone effects on selected crop yields. The assessment ...
The purpose was to develop a simplified and reliable method of separating free from antibody-bound ligand using a precipitating antibody linked to a cellulose derivative. Dose-response curves and control sera were set up in parallel for various pituitary and placental polypeptides, steroid hormones, insulin, glucagon, triiodothyronine, thyroxine, angiotensin I, calcitonin, gastrin, cyclic AMP, and digoxin. After first-antibody reactions had reached equilibrium, free and bound ligand were separated using a double-antibody solid-phase system in parallel with conventional methods, including dextran-coated charcoal, double-antibody precipitation, single-antibody solid phase, organic solvents, salt precipitation, and anion-exchange resins. The effect of variations in temperature, incubation time, protein content, pH, and amount of separating material added were studied. The results showed that separation was complete within 1 hr for small ligand molecules and within 2 ...
The purpose was to develop a simplified and reliable method of separating free from antibody-bound ligand using a precipitating antibody linked to a cellulose derivative. Dose-response curves and control sera were set up in parallel for various pituitary and placental polypeptides, steroid hormones, insulin, glucagon, triiodothyronine, thyroxine, angiotensin I, calcitonin, gastrin, cyclic AMP, and digoxin. After first-antibody reactions had reached equilibrium, free and bound ligand were separated using a double-antibody solid-phase system in parallel with conventional methods, including dextran-coated charcoal, double-antibody precipitation, single-antibody solid phase, organic solvents, salt precipitation, and anion-exchange resins. The effect of variations in temperature, incubation time, protein content, pH, and amount of separating material added were studied. The results showed that separation was complete within 1 hr for small ligand molecules and within 2 ...
The patients studied were referred for routine abscess localization with indium-111 labelled autologous leukocytes. One series (n=15) was studied at 1 day after reinjection of labelled cells and a second series (n=9) was studied between 4 hours and 4 days after reinjection of labelled cells. The leukocytes were isolated by a gravity sedimentation method and labelled with In-111 oxinate according to Roevekamp and co-workers. The labelled cell suspension administered to the patient contained between 11 and 15 MegaBq (300-400 microCi). The indium-111 concentration in the liver and spleen was quantitated using a scintillation camera and an on-line computer system. Phantom studies were carried out to obtain conversion factors from geometric mean counts to MegaBq of activity for both liver and spleen. Once determined, the amount of activity in liver and spleen was corrected for physical decay of In-111 and expressed as a percentage of the administered activity. ...
The space environment consists of a varying field of radiation particles including high-energy ions, with spacecraft shielding material providing the only major protection to astronauts from harmful exposure. Unlike low-linear energy transfer (LET) {gamma} or X-rays, the presence of shielding does not always reduce the radiation risks for energetic charged particle exposure, since the dose delivered by the charged particle increases sharply as the particle approaches the end of its range, a position known as the Bragg peak. The Bragg curve does not necessarily represent the biological damage along the particle traversal, and the 'biological Bragg curve' is dependent on the energy and the type of the primary particle, and may vary for different biological endpoints. Here we used a unique irradiation geometry to measure the biological response across the Bragg curve in human fibroblasts exposed to 577MeV/nucleon incident Fe ions ...
Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available
... radiation during clinical therapy and exposures due to radiation accidents or attacks, in which the doses are uncontrolled ... only be used off-label in victims of radiation accidents or attacks. The idea...
OBJECTIVETo assess the new quantitative bone scan parameters as markers of Charcot neuroosteoarthropathy (CNO) activity.RESEARCH DESIGN AND METHODSForty-two...Full Text Available
Emphasis was put on the comparative quantitative structure-activity approaches to the exploration of action mechanisms of structurally different classes of compounds showing the same type of activity...Full Text Available
Effective small interfering RNA (siRNA)–mediated therapeutics require the siRNA to be delivered into the cellular RNA-induced silencing complex (RISC). Quantitative information of this essential...Full Text Available
A single radial hemolysis test was developed for quantitation of specific antibody to non-hemagglutinating viruses. With the human coronaviruses as models, this test utilizes the binding properties...Full Text Available
We have exploited ``progeny testing'' to map quantitative trait loci (QTL) underlying the genetic variation of milk production in a selected dairy cattle population. A total of 1,518 sires, with progeny...Full Text Available
Gene expression data has been used in lieu of phenotype in both classical and quantitative genetic settings. These two disciplines have separate approaches to measuring and interpreting epistasis, which...Full Text Available
Deficits in prepulse inhibition (PPI) are a biological marker for schizophrenia. To unravel the mechanisms that control PPI, we performed quantitative trait loci (QTL) analysis on 1,010 F2 mice derived...Full Text Available
The Electronic REference To access In vivo Concentrations (ERETIC) method was applied to 1H HR-MAS spectroscopy. The accuracy, precision, and stability of ERETIC as a quantitative...Full Text Available
The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.
The case of spontaneous radiation of channeled ultrarelativistic particles is considered when the dipolarity condition is not satisfied. The change of the particle longitudinal velocity affecting the maximum radiation frequency is included. The angular and frequency characteristics of the radiation for superhigh energies are studied for the first time. It is shown that there is an optimum energy at which the radiation density is maximum. The influence of the angle at which electrons enter a crystal and of the beam divergence on the radiation is investigated. The problem of quasichanneled particle radiation and also the radiation in axis-plane transitions are considered. (author).
The two-compartment radioassay for microbial kinetics based on continuous measurement of the {sup 14}CO{sub 2} released by bacterial metabolism of 14C-labeled substrate offers a valuable approach to testing the potency of antimicrobial drugs. By using a previously validated radioassay with gram-positive and gram-negative bacteria, a group of protein synthesis inhibitors was evaluated for their effect on microbial growth kinetics. All tested drugs induced changes in both the slopes and intercepts of the growth curves. An exponential growth model was applied to quantify the drug effect on the processes of bacterial {sup 14}CO{sub 2} liberation and cell generation. The response was measured in terms of a generation rate constant. A linear dependence of the generation rate constant on the dose of spectinomycin was observed with Escherichia coli. Sigmoidal-shaped curves were found in the assays of chloramphenicol and tetracycline. The implications of dose-response ...
The study investigated the luminescence behaviour of natural olivine to discuss the potential for Cenozoic (quaternary) dating. The UV-blue thermoluminescence (TL) glow curves of irradiated olivines have a resolved peak at 190 deg. C and other peaks at higher temperature at lower dose levels, and broad signals around 275-310 and 375-400 deg. C at higher dose levels. The UV-blue TL increases with additional laboratory dose to {approx}1.6kGy within a plateau temperature region, suggesting the possibility of dosimetry and Cenozoic dating. Both infrared stimulated luminescence (IRSL) and blue light stimulated luminescence (BLSL) were detected from laboratory-irradiated olivines although the BLSL was weaker than the IRSL. Furthermore, post-BL IRSL was detected but post-IR BLSL was not observed. Therefore, IR stimulation is recommended for optically stimulated luminescence measurements with natural olivine. The growth of the IRSL signal component with doses less than several tens of Gy are ...
Reference is made to Cheng and Leblond (Amer. J. Anat.; 141:537 (1974)) who used tritiated thymidine to kill cells synthesising DNA in the crypts of the small intestine. Amongst their findings was that very low doses caused measurable cell killing and that the killing was not random throughout the crypt but occurred selectively at the crypt base where stem cells are presumably located. It is here reported that the presence of hypersensitive cells at the base of the crypts can be demonstrated after whole-body X- or gamma-irradiation, and the time sequence for the production and loss of the killed cells is described together with their dose-response relationship. The studies were conducted on mice. The data were expressed as surviving rather than killed cells, and it was established that the crypt are amongst the most sensitive of mammalian cells. The mechanism by which these sensitive cells are killed is not known, but DNA damage can be detected. The vital stem ...
The purpose of this study was to determine whether low doses of carbon monoxide (CO) exacerbate myocardial ischemia during a progressive exercise test. The effect of CO exposure was evaluated using the objective measure of time to development of electrocardiographic changes indicative of ischemia and the subjective measure of time to onset of angina. Sixty-three male subjects (41-75 years) with well-documented coronary artery disease, who had exertional angina pectoris and ischemic ST-segment changes in their electrocardiograms, were studied. Results from three randomized, double-blind test visits (room air, low and high CO) were compared. The effect of CO exposure was determined from the percent difference in the end points obtained on exercise tests performed before and after a 1-hr exposure to room air or CO. A significant dose-response relationship was found for the individual differences in the time to ST end point and angina for the pre-versus postexposure ...
Changes in contents of the two kinds of neuropeptides have been measured in the brains of postnatal G57BL/6J strain mice that received accumulative doses of 0, 0.05, 0.10 or 0.30 Gy respectively in utero from tritium #beta#-irradiation during the mother mice's pregnancy from the 12.5th day of gestation to the day of delivery. Doseresponse relationship for alteration in somatostatin content due to exposure to 0.10 Gy or above was observed, and it was also noted that 0.30 Gy could cause decrease in arginine vasopressin in hypothalamus. These results were consistent with findings in research on brain development and reflex behavior in the literature. 0.10 Gy exposure may represent a threshold for exposure to tritiated water within the range from day 12.5 of gestation to the day of delivery using change in content of somatostatin in hypophysis as a parameter.
Pregnant rats in 11d and 16d of their pregnancy were given one-off whole body exposure by "1"3"7Cs #gamma# rays to 0.2, 0.4, 0.9 and 2.0 Gy, respectively. Changes were observed in conditioned drinking response and cerebrum hippocampi cone cell number of the baby rats exposed to the #gamma# rays in different periods of their embryo development. As a result, that pregnant rats exposed to "1"3"7Cs #gamma# rays in different pregnant periods may induce significant decrease in cerebrum hippocampi cone cell number and achieving rate of conditioned drinking response of the babies. The dose-response relationship can be described by Y=a-b log_1_0D. The achieving rate of conditioned drinking response were significantly correlated to cerebrum hippocampi cone cell number in the babies, and the achieving rate of conditioned drinking response of the babies exposed at pregnant 11d was lower than others exposed at pregnant 16d
Systematics of neutron capture radiative width were studied in the target element range from Th to Cm. Reduced radiative widths were analyzed with a simple radiative width formula based on E1 transition. Average radiative width is presented with the standard deviation of 15%. (author)
Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)
The central benzodiazepine receptor tracer [N-methyl-"1"1C]iomazenil (Ro 16-0154) was synthesized by alkylation of the desmethyl precursor noriomazenil with ["1"1C]methyl iodide. The ["1"1C]CH_3I (prepared by reduction of ["1"1C]CO_2 with LiAlH_4 followed by reaction with HI) was reacted with noriomazenil inN,N -dimethylformamide and Bu_4N"+OH"- for 1 min at 80 deg. C and purified by HPLC (C_1_8, 34% CH_3CN/H_2O, 7 mL/min). The product was obtained with synthesis time 35 #+-# 5 min (mean #+-# SD, n = 7), radiochemical yield (EOB) 36 #+-# 16%, radiochemical purity 99 #+-# 1%, and specific activity 5100 #+-# 2800 mCi/#mu#mol. Absorbed radiation doses were calculated from previously acquired human biodistribution data. The urinary bladder wall received the highest dose (0.099 mGy/MBq) for 4.8 h voiding interval and the effective dose equivalent was 0.015 mSv/MBq. After i.v. injection of ["1"1C]iomazenil in an adult baboon or healthy human volunteer, radioactivity ...
Three copper-based alloys, CDA 102 (oxygen-free, high-purity copper), CDA 613 (aluminum bronze), and CDA 715 (Cu-30Ni), are candidates for the fabrication of high-level radioactive-waste disposal containers. Waste will include spent fuel assemblies from reactors as well as borosilicate glass, and will be sent to the prospective repository site at Yucca Mountain in Nye County, Nevada. The decay of radionuclides will result in the generation of substantial heat and in fluxes of gamma radiation outside the containers. In this environment, container materials might degrade by atmospheric oxidation, general aqueous phase corrosion, localized corrosion (LC), and stress corrosion cracking (SCC). This volume is a critical survey of available data on pitting and crevice corrosion of the copper-based candidates. Pitting and crevice corrosion are two of the most common forms of LC of these materials. Data on the SCC of these alloys is surveyed in Volume 4. Pitting usually ...
Since the Scientific Assessment of Ozone Depletion: 1998, numerous laboratory investigations, atmospheric observations, and theoretical and modeling studies have produced new key findings and have strengthened overall understanding of the ozone layer and its effect on ultraviolet (UV) radiation. These advances are highlighted in the following summary of the current understanding of the impact of human activities and natural phenomena on the ozone layer and the coupling of the ozone layer and the climate system. In the troposphere (i.e., lower atmosphere), observations show that the total combined effective abundance of ozone-depleting compounds continues to decline slowly from the peak that occurred in 1992-1994. Total chlorine is declining, while bromine from industrial halons is still increasing, albeit at a slower rate than was occurring previously (and as reported in the 1998 Assessment). Analyses of air trapped in snow since the late 19th century have ...
Optimal design of the hyperfractionated radiotherapy requires basic radiobiological data such as the critical dose per fraction, number of fractions per day and total equivalent dose, to name a few. As a prelude to in vivo hyperfractionated irradiation, the authors carried out experiments to determine quantitative changes in the proliferation and cell kinetic parameters of multicellular spheroids after hyperfractionated irradiation. Experiments were carried out with HeLa S-3 spheroid growing in MEM culture media. Hyperfractionated irradiation schedules were 1.5 Gy/f, 2f/day and 1.0 Gy/f, 3 f/day. At intervals after irradiation, cell numbers, growth delays and cell cycle distribution of spheroids were determined. The kinetic data were obtained by the use of flow cytometry. The most pronounced changes in cell kinetic parameters were early G/sub 2/M block, proportional to single radiation dose up to 4.0 Gy. There was a corresponding depletion of ...
The convolution/superposition algorithm for computing dose from photon beams in radiation therapy planning requires knowledge of the energy spectrum. The algorithm can compute the dose for a polyenergetic beam as the weighted sum of the individual dose contributions from monoenergetic beams. In this study we exploit interface effects apparent in the dose distributions to discriminate among spectra of high energy photon beams. We have studied the sensitivity of the depth dose distribution to the energy components using a hypothetical beam for various field sizes and depths in water and water-lung-water media. Six theoretical spectra were simulated. We compared depth dose data from these spectra using three quantitative measures which are inherently free of normalization ambiguities: for homogeneous water, the ratio D_2_0/D_1_0 and a logarithmic derivative in the buildup region LD_b_u_i_l_d_-_u_p and for inhomogeneous lung/water, the lung ...
High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions can be quantitatively evaluated thermoluminescent dosimeter (TLD) chips with a dimension of 1/8 and film dosimetry with a spatial resolution of <1 mm used to measure the radiation ...
We describe the development of a fully coupled climate model configuration where the Community Climate System Model (CCSM) has been coupled with the VERDE (Visualizing Energy Resources Dynamically on the Earth) analysis modules that compute the response of the electric grid to temperature drivers. The VERDE model includes datasets characterizing the 26,500 sub-stations and 6,000 power generation stations fuel mix, efficiency, service areas, and future performance and these have been geo-located on a 1.4 degree latitude by 1.4 degree longitude CCSM grid (T85). The total electric customers have been computed using conversions derived from economic structure and population data. The carbon emissions per customer and the power generation in megawatts electric (MWe) have also been placed on reconciled 1 km, 4 km and the T85 climate model grid. The CCSM temperature for the present and future have been extracted from the climate model output and placed on the same grid as the VERDE substation ...
Recent advances in self-amplified spontaneous emission (SASE) experiments stimulate interest in quantitative comparison of measurements with theory. In this paper we show that the widely used simulation code TDA3D, developed by Tran and Wurtele [Comput. Phys. Commun. 54, 263 (1989)] even though a single frequency code, can be used to determine the output power in the SASE process with excellent approximation in the exponential growth regime. The method applies when the gain is not very high, which is a special advantage, because when the gain is not very high, the analytical calculation is particularly difficult since the exponential growing term does not dominate. The analysis utilizes a scaling relation between the output power and the number of simulation particles in the code TDA3D: left-angle P right-angle=N_#lambda#"'/N_#lambda# left-angle P"'right-angle, where left-angle P right-angle is the output power and N_#lambda# is the line density of the electrons, ...
German translation of the publication 'The evaluation of risks from radiation' published in 1965 by the International Commission on Radiological Protection. In a survey, genetic and somatic risks from radiation are presented and explained. (HP).
This book gives an overview of the entire field of radiation protection with the subject areas radioactivity, X-rays, UV radiation, laser beams and high-frequency electromagnetic fields. It deals graphically with the most important physical notions, the incidence, origin, properties and biological effects of types of radiation, administrative and practical protection measures and the code of rules governing them. Apart from fundamentals of radiation protection the emphasis on the following: natural radiation exposure, radiation exposure to radon, disaster relief plans in the environment of nuclear plant, the precautionary radiation protection system evolved after Chernobyl, radiation exposure through UV radiation devices, radio, RF communication, radar, microwave ovens and high-voltage transmission ...
Iodized oil has been used as a contrast agent in lymphangiography. One of the commercially available compounds is Lipidol Ultra-fluid(LUF) which contains 38% iodine by weight. Nakakuma et al(1979) reported that LUF was selectively retained in the hypervascular hepatocellular carcinoma when injected directly into the ligated hepatic artery. Since that time, it has been widely utilized in the detection as well as the therapeutic attempts of hepatocellular carcinoma, where it has been mixed with chemotherapeutic agents or labeled with radioactive I-131. Like all significant advances, the mechanism of lipid retention within the hepatocellular carcinoma is not clearly understood, and also there is a lack of information about the biodistribution and kinetics of I-131 Lipiodol. The apparent safety of this technique require confirmation. The present study was aimed to assess the biodistribution and kinetics of intraarterially injected I-131 Lipiodol and the histologic changes in canine livers. ...
Subject to the provisions of the Radiation Protection Act, the Authority, on the advice of ...(f) in collaboration with the Radiation Protection Board, conduct an ionising radiation monitoring programme and ...or document kept under the control of the Radiation Protection Board.
Described and discussed in this paper are radiation processes and their advantages over the conventional techniques. Radiation sterilization of medical products, food irradiation, wood plastic composites, and radiation treatment of sewage and waste waters are presented. The Philippine experience in using these technologies, its problems and barriers are also given. (ELC).
AFFF has fabricated the (U, Pu)O_2 mixed oxide fuels for PHWRs, BWRs, PFBRs and FBTRs. The quantitative dissolution of the fuel samples are required within time for accurate determination of uranium-plutonium in chemical quality control laboratory. This paper describes the use of microwave heating technique in quantitative dissolution of (U, Pu)O_2 MOX (from 0.4% to 44% PuO_2). (author)
This text-book (electronic book - multi-media CD-ROM) constitutes a course-book - author's collection of lectures. It consists of 13 lectures in which the reader acquaints with the basis of radiobiology: Introduction to radiobiology; Physical fundamentals of radiobiology; Radiation of cells; Modification of radiation damage of cells; Reparation of radiation damage of cells; Radiation syndromes and their modification; Radiation injury; Radiation damage of tissues; Effect of radiation on embryo and fetus; Biological effects of incorporated radionuclides; Therapy of acute irradiation sickness; Delayed consequences of irradiation; Radiation oncology and radiotherapy. This course-book may be interesting for students, post-graduate students of chemistry, biology, physics, medicine as well as for teachers, scientific workers ...
... Radiation Protection Products and Equipment Find and compare a variety of radiation protection products and equipment on the world's largest environmental industry portal. View product ...
... These assumptions are quantitatively investigated by calculating tie icldti\\e inportance of ... A modified lon-shore current model is used to study the ...
BackgroundDiscrepancies between the conclusions of different meta-analyses (quantitative syntheses of systematic reviews) are often ascribed to methodological differences. The objective...Full Text Available
A specific application of single photon emission tomography to the relative quantitation of the pituitary region is described together with the results obtained in 19 patients with pituitary adenoma...Full Text Available
Motivation: Automatic recognition of cell identities is critical for quantitative measurement, targeting and manipulation of cells of model animals at single-cell resolution. It has been...Full Text Available
Typing Workshop": [Introductions] [Intro, DNA Basics, and Historical Perspective] [DNA Extraction] [Validation and QA/QC] [DNA Quantitation] [PCR Amplification] [STR Loci and Kits]...
BACKGROUND: An approach to the study of the pharmacokinetics of drugs in the lung is to measure their concentrations in bronchial biopsy specimens. The main criticism of this technique is that bronchial...Full Text Available
This laboratory exercise demonstrates some basic principles in parasitology by using experimental studies of the relationship of Hymenolepis diminuta with its rodent host.
Abstract: The current financial crisis has now led most major central banks to rely on quantitative easing. The unique Japanese experience of quantitative easing is the only experience which enables us to judge this therapy's effectiveness and the timing of the exit strategy. In this paper, we provide a new empirical framework to examine the effectiveness of Japanese monetary policy during the ''lost'' decade and quantify the effect of quantitative easing on Japan's activity and prices. We combine advantages of Markov-switching VAR methodology with those of factor analysis to establish two major findings. First, we show that the decisive change in regime occurred in two steps: it crept out from late 1995 and established itself durably in February 1999. Second, we show for the first time th...
Absolute measurements of cerebral blood flow (CBF) are an important endpoint in studies of cerebral pathophysiology. Currently no accepted method exists for in vivo longitudinal...Full Text Available
... and high-quality photospheric-phase Type II SN spectra to constrain core- collapse SN explosions, massive star evolution, and distances in the Universe ...
OBJECTIVEEvaluate the qualitative and quantitative differences between moderated and unmoderated on-line social support groups focused on asthma.DESIGNA...Full Text Available
Computer-Aided Prediction of Chemical Ecotoxicity on the basis of Quantitative Structure-Activity Relationships with the Use of Physico-Chemical Descriptors, Including H-bond Parameters
AIM: To investigate the effects of gallbladder stones on motor functions of the gallbladder and the dynamics of bile flow in asymptomatic gallstone disease.METHODS: Quantitative hepatobiliary...Full Text Available
BackgroundSeveral fractal and non-fractal parameters have been considered for the quantitative assessment of the vascular architecture, using a variety of test specimens and of computational...Full Text Available
OBJECTIVE AND DESIGNThis study used qualitative and quantitative methods to examine the reasons primary care physicians and nurses offered for their inability to initiate guideline-concordant...Full Text Available
The concentration of apolipoproteins was measured by quantitative immunoelectrophoresis in rat serum, in the lipoprotein-free ultracentrifugal fraction (density greater than 1.21) of serum, and in renal...Full Text Available
In this model, without dark matter, the flat rotation curves of galaxies and the mass-to-light ratios of clusters of galaxies are described quantitatively. The hypothesis is that the agent of gravitational...Full Text Available
This chapter is concerned with standards and guidances for limiting radiation exposures. It is divided into three sections, each of which has several parts. Section 1: Ionizing Radiation -- Standards and Guidances Applicable to the Public: Part A, Radiation Protection Standards; Part B, Environmental Radiation Standards; Part C, Exempt Levels of Radioactivity; Part D, Protective Action Guides for Accidents. Section 2: Ionizing Radiation -- Standards Applicable to the Workplace. Section 3: Medical and Other Standards.
On the basis of legally provided area dose measurements and time records of fluoroscopic examinations during the operation, radiation doses to medical personnel and patients are evaluated. Adequate radiation protection measures and a careful behaviour in the operating room keep the radiation exposure to the personnel below the maximum permissible exposure. Taking into account the continuous personnel radiation monitoring and medical supervision, radiation hazards in the operating room can be considered low.
The current state and need for radiation protection training in Finland have been surveyed by the Radiation and Nuclear Safety Authority STUK. The survey sought to determine whether the current requirements for radiation protection training had been met, and to promote radiation protection training. Details of the scope and quality of present radiation protection training were requested from all educational institutes and organizations providing radiation protection training. The survey covered both basic and further training, special training of radiation safety officers, and supplementary training. The questionnaire was sent to 77 educational organization units, 66 per cent of which responded. Radiation workers and radiation safety officers were asked about radiation protection ...
We characterized the absorption and short-term translocation of cadmium (Cd) in rice (Oryza sativa ‘Nipponbare’) quantitatively using serial images observed with a positron-emitting...Full Text Available
A method for the quantitative determination of atmospheric hydroperoxyl radical comprising: (a) contacting a liquid phase atmospheric sample with a chemiluminescent compound which luminesces on contact with hydroperoxyl radical; (b) determining luminescence intensity from the liquid phase atmospheric sample; and (c) comparing said luminescence intensity from the liquid phase atmospheric sample to a standard luminescence intensity for hydroperoxyl radical. An apparatus for automating the method is also included.
Gas chromatography-selected ion monitoring-mass spectral analysis using [13C6]indole-3-acetic acid (IAA) as an internal standard provides an effective means for quantitation of...Full Text Available
A quantitative description is proposed for the depletion-induced slip thickness and velocity profile of a polymer solution near the wall-fluid interface in simple shear flow. The inhomogeneous polymer density profile at a flat wall is inserted into the equations of motion for the flow of a polymer solution near the flat wall. The theory is in quantitative agreement with simulation results. (letter to the editor)
A quantitative description is presented of the non-linear current-voltage response in superconducting niobium cavities for accelerator application. It is based on a fit for a large sample of data from cavity tests of different kind. Trial functions for the surface resistance describing this non-linear relation are established by a least square data fit. Those trial functions yielding the best fit are quantitatively explained by basic physics.
An (Awassi × Merino) × Merino backcross family of 172 ewes was used to map quantitative trait loci (QTL) for different milk production traits on a framework map of 200 loci across all...Full Text Available
Studies have been performed with an anti-osteogenic sarcoma monoclonal antibody 791T/36 and human tumour xenografts to examine some of the quantitative and kinetic aspects of tumour localization. The influence of variations in tumour size and site and antibody dose on the extent and rate of specific antibody localization have been examined, together with the site of intratumoural deposition of the antibody. (UK).
The overall objective of this project is to produce antibodies to unique modified DNA bases and develop immunochemical assays to quantitate these lesions in damaged DNA. During this past year we have developed an antibody and chemical test to quantitate a basic sites in DNA and produced antibodies to the 8-oxopurines. This report discusses the detection of a basic sites in DNA and the preparation of antibodies to 8-hydroxyadenine and 8-hydroxyguanine.
The assumed linear relationship between exposure to radiation and cancer incidence is questioned in this article. The current research data on radiation effects at the cellular level is reviewed, as are epidemiological studies of background radiation effects and health effects of populations exposed to low levels of radiation exposure via employment or medical treatments. Statistics reveal that threshold levels currently in force need to be reviewed. Some evidence of beneficial effects of low level radiation exposure effects of low level radiation exposure is also presented, and so regulations should be reviewed at an international level. (UK).
The most propagated mechanisms of stimulated radiation of electron beam such as Cherenkov one-particle and collective effects, ondulator and magnetic bremsshrahlung radiations, Doppler anomalous effect, Thompson and Raman scattering and radiation are discussed. Relation of spontaneous radiation mechanisms of individual electron and stimulated radiation effects in electron beams has been elucidated, grounds of linear electrodynamics of radiative beam instabilities are stated, and main mechanisms of their nonlinear stabilization are elucidated as well. Various simulated processes in electron beams are considered from the unique point of view using a simple mathematical apparatus and such physical laws as conservation and Newton laws.
The need for noninvasive sensitive techniques for the diagnosis and follow-up of metabolic bone disease in dialysis patients has stimulated the author's interest in the efficacy of more detailed quantitative bone scintigraphy. Using hemodialysis to reduce elevated soft-tissue activity at scintigraphy, an attempt was made to assess the diagnostic sensitivity of quantitative bone scintigraphy as compared to qualitative bone scintigraphic, biochemical, radiographic and bone histologic studies. The second aim of these studies was to determine if one of the two major components of renal osteodystrophy is a major determinant for skeletal radiotracer uptake. The clinical observations on the efficacy and possible specificity of quantitative bone scintigraphy in the diagnosis and follow-up during treatment of renal osteodystrophy are presented briefly in this chapter. Thus, the use of scintigraphy for the routine detection and ...
Sesame varieties/genotypes showed a good response to radiation with gamma rays and treatments with EMS. In M_1 both gamma rays and EMS influenced germination, seedling height, survival of plants and pollen fertility/sterility, producing deleterious effects on these characters. Compared to black seeded genotypes, white seeded ones are more susceptible to radiation. Both gamma rays and EMS produced various types of morphological variations in M_2 generation. These were dwarf plant mutants, mottled and fleshy leaved mutants (sterile), fasciated stem, flower colour, altered phyllotaxy, early, uniculm, capsule size variations, multiple capsule/leaf axil, seed coat colour variations, indehiscent and semi-indehiscent type mutants. Moreover, studies on quantitative characters including seed yield revealed the induction of mutants in both positive and negative directions for such traits which made a good scope of selection of ...
This manual was written for individuals who wish to become qualified in radiation protection as an adjunct to working with sources of ionizing radiation or using radionuclides in the field of medicine. It provides the radiation user with information needed to protect himself and others and to understand and comply with governmental and institutional regulations regarding the use of radionuclides and radiation machines. It is designed for a wide spectrum of users, including physicians, research scientists, engineers, and technicians. It should be useful also to radiation safety officers, members of radiation safety committees, and others who are responsible for the proper use of radiation sources, although they may not be working with the sources directly. The presentation in this manual is designed to obviate the need for reviews of atomic ...
Abstract Satellite measurements and numerical forecast model reanalysis data are used to compute an updated estimate of the cloud radiative effect on the global multi-annual mean radiative energy budget of the atmosphere and surface. The cloud radiative cooling effect through reflection of short wave radiation dominates over the long wave heating effect, resulting in a net cooling of the climate system of - 21 Wm-2. The short wave radiative effect of cloud is primarily manifest as a reduction in the solar radiation absorbed at the surface of - 53 Wm-2. Clouds impact long wave radiation by heating the moist tropical atmosphere (up to around 40 Wm-2 for global annual means) while enhancing the radiative cooling of the atmosphere over other regions, in particular higher latitudes and sub-trop...
In the present study, the immunomodulatory effect of {beta}-endorphin ({beta}-E) and shorter pro-opiomelancortin (POMC) fragments was evaluated by assessing their influence on respiratory burst in human polymorphonuclear leukocytes (PMN). The effect of the peptides on phorbol myristate acetate (PMA)-stimulated production of reactive oxygen metabolites was measured in a lucigenin-enhanced chemiluminescence (CL) assay. Both POMC peptides with opiate-like activity and their non-opioid derivatives were tested. With the exception of {alpha}-E, PMA-stimulated respiratory burst was suppressed by all POMC fragments tested. A U-shaped dose-response relation was observed. Doses lower than 10{sup {minus}17}M and higher than 10{sup {minus}8}M were without effect. {beta}-E and dT{beta}E both suppressed PMA-induced oxidative burst in human PMN at physiological concentrations. {gamma}-E and dT{gamma}E proved to be less potent inhibitors, reaching maximal effect at higher ...
A comparison of the concentration-response effects of inhaled ozone (O/sub 3/) in different species of laboratory animals was made in order to better understand the influence of the choice of species in inhalation studies of this gas. The effect of 4-hour exposure to ozone (O/sub 3/) at concentrations of 0.0, 0.2, 0.5, 1.0, and 2.0 ppm was determined in rabbits, guinea pigs, rats, hamsters and mice. Lavage fluid protein (LFP) accumulation 18 hr after exposure was used as the indicator of O/sub 3/-induced pulmonary edema. All species had similar basal levels of LFP (250-350 ug/ml) when a volume of saline which approximated the total lung capacity was used for lavage of the collapsed lungs. Exponential dose-response curves were seen in all species except guinea pigs, which showed significant increases in LFP at low O/sub 3/ concentrations (0.2 ppm) and a leveling off of response at the higher O/sub 3/ levels. Other species usually showed significant elevations in LFP ...
Numerous laboratory investigations have shown that sulfur dioxide (SO/sub 2/) induces bronchoconstriction and respiratory symptoms in exercising asthmatics. These effects appear to depend on dose rate (the product of exposure concentration and ventilation rate), and may occur at dose rates attainable during outdoor exercise in SO/sub 2/-polluted communities. Effects are rapid in onset, requiring no more than 5 min of exercise during exposure. Thus they may be induced by transient elevations of SO/sub 2/ levels, which may occur near large pollution sources even when longer-term average concentrations meet existing air quality standards. Even very mild asthmatics typically are far more sensitive to SO/sub 2/ than healthy volunteers. The authors discuss an investigation designed to expand and improve the dose-response information on SO/sub 2/. In comparison to earlier work it employed a larger, clinically more diverse population of volunteer subjects. Comparatively ...
Pulsatile hormone secretion is observed in almost every hormonal system. The frequency of episodic hormone release ranges from approximately 10 to 100 pulses in 24 hours. This temporal mode of secretion is an important feature of intercellular information transfer in addition to a dose-response dependent regulation. It has been demonstrated in a number of experiments that changes in the temporal pattern of pulsatile hormone secretion specifically regulate cellular and organ function and structure. Recent evidence links osteoporosis, a disease characterized by loss of bone mass and structure, to changes in the dynamics of pulsatile parathyroid hormone (PTH) secretion. In our study we applied nonlinear and linear time series prediction to characterize the secretory dynamics of PTH in both healthy human subjects and patients with osteoporosis. Osteoporotic patients appear to lack periods of high predictability found in normal humans. In contrast to patients with ...
Background: In the German CESS-studies, Ewing's sarcoma patients with pulmonary metastases at diagnosis were considered as candidates for additional bilateral lung irradiation. We have retrospectively analyzed the impact of radiotherapy on survival. Material and methods: Out of 42 patients presenting with pulmonary metastases of Ewing's sarcoma between 1981 and June 1992, 30 were evaluable. One patient died of progressive disease prior to lung irradiation. The other patients had a complete radiographic remission either after chemotherapy (n=25) or chemotherapy plus resection of lung metastases (n=4). 22 patients received bilateral lung irradiation with doses of 12 to 21 Gy (once daily 1.5 Gy or twice daily 1.25 Gy), six had no further treatment and one had bone marrow transplantation for consolidation. Results: Ten patients are in complete remission, nine of them had received lung irradiation and one had a complete resection of three lung metastases. Two patients are alive with ...
Spontaneous mutation has been discovered and utilized in domestication of narrow-leafed lupin (Lupinus angustifolius L.). As the result of the domestication, lupin has become a dominant grain legume crop in Western Australia. Facing the new challenge of developing herbicide tolerance cultivars, chemical mutagenesis has been used to create new tolerance to herbicide. This paper reports the characterization of two lupin mutants (Tanjil-AZ-33 and Tanjil-AZ-55) that are highly tolerant to metribuzin herbicide. A doseresponse study over 8 doses revealed that Tanjil-AZ-33 was 6 times more tolerant to metribuzin than the original parental cultivar Tanjil by measure of LD50. This mutant Tanjil-AZ-33 is the most tolerant germplasm in narrow-leafed lupin. Both mutants also maintain the high resistance to the disease anthracnose as cv Tanjil. Seed yield based on small field plots (3.6 m"2) under irrigation was 4.2 t/ha for Tanjil-AZ-33 and 1.9 t/ha for ...
The receptor occupancy-biological effect relationship for muscarinic receptors in guinea pig ileal smooth muscle has been studied by comparison of radioligand binding and contractile response. Muscarinic receptors in homogenates of ileal smooth muscle were labeled with (/sub 3/H)-1-Quinuclidinyl benzilate. Treatment with propylbenzilylcholine mustard (PrBCM), to inactivate irreversibly muscarinic receptors, caused a large dose dependent rightward shift of the dose-response curve to three agonistic furtrethonium derivatives with a concomitant decrease in maximal response. Using those data, the fraction of receptors remaining unoccupied (q-values) and true affinity constants (-log K/sub A/-values) were calculated. Exposure to 20 or 60 nM PrBCM for 15 minutes resulted in a 39% and a 61% reduction in specific (/sup 3/H)-1-Quinuclidinyl benzilate binding sites respectively to be compared with a 62% and a 85% decrease expected from calculated q-values. K/sub A/-values ...
The hypothesis that intracellular Ca/sup 2 +/ is an essential component of the intracellular mechanism of insulin action in the adipocyte was evaluated. Cells were loaded with the Ca/sup 2 +/ chelator quin-2, by preincubating them with quin-2 AM, the tetrakis(acetoxymethyl) ester of quin-2. Quin-2 loading inhibited insulin-stimulated glucose transport without affecting basal activity. The ability of insulin to stimulate glucose uptake in quin-2-loaded cells could be partially restored by preincubating cells with buffer supplemented with 1.2 mM CaCl/sub 2/ and the Ca/sup 2 +/ ionophore A23187. These conditions had no effect on basal activity and omission of CaCl/sub 2/ from the buffer prevented the restoration of insulin-stimulated glucose uptake by A23187. Quin-2 loading also inhibited insulin-stimulated glucose oxidation and the ability of insulin to inhibit cAMP-stimulated lipolysis without affecting their basal activities. Incubation of cells with 100 ..mu..M quin-2 or quin-2 AM had ...
The hypothesis that intracellular Ca"2"+ is an essential component of the intracellular mechanism of insulin action in the adipocyte was evaluated. Cells were loaded with the Ca"2"+ chelator quin-2, by preincubating them with quin-2 AM, the tetrakis(acetoxymethyl) ester of quin-2. Quin-2 loading inhibited insulin-stimulated glucose transport without affecting basal activity. The ability of insulin to stimulate glucose uptake in quin-2-loaded cells could be partially restored by preincubating cells with buffer supplemented with 1.2 mM CaCl_2 and the Ca"2"+ ionophore A23187. These conditions had no effect on basal activity and omission of CaCl_2 from the buffer prevented the restoration of insulin-stimulated glucose uptake by A23187. Quin-2 loading also inhibited insulin-stimulated glucose oxidation and the ability of insulin to inhibit cAMP-stimulated lipolysis without affecting their basal activities. Incubation of cells with 100 #mu#M quin-2 or quin-2 AM had no effect on intracellular ...
The biological age (BA) of the majority of the liquidators of the consequences of the radiation accidents in the Navy and of the liquidators of the Chernobyl' APS accident exceeds the medium standard and the DBA (due BA). The index of the BA can be a characteristic of the influence of the social-hygienic factors on the health condition of the Special Risk Subunit--the liquidators of the consequences of the radiation accidents. It was established, that the radiation influence concerns to the factors dramatically increasing the BA and the rate of senescence of the liquidators of the consequences of the radiation accidents. PMID:21809627
The experimental device for generation of undulator radiation in terahertz wavelength region by use of undulator with ferromagnets is created. The device is based on a beam of a microtron with the energy 7.5 MeV. The radiation wavelength is 200 mu. Registered spontaneous radiation has a power 10{sup -6} W at a current of a beam 2 mA in a pulse. With the optical resonator, in a mode, the amplification of 6% is received, that in sometimes is more than the expected value. This effect is explained as a result of partial coherence of radiation.
The emission of Cerenkov radiation by tachyons has been examined by using the reduced expansions of superluminal electromagnetic fields in terms of standard helicity representation of Poincare group. It has been shown that the tachyons emit Cerenkov radiation through their coupling only with subluminal electromagnetic fields and that a charged tachyon can emit Cerenkov radiation only in the media in which it travels with a velocity lower than that of light while in the usual medium in which its velocity is more than that of light, it will never emit Cerenkov radiation.
Characteristics of the Ukrainian NSA NRI radiation facility for scientific researches and developments of industrial radiation technology are performed. Parts of the facility, design peculiarities of technical tools are described. Biological protection of the facility and radiation protection system, transport line, systems of technical provision and radiation measurements are discussed
The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.
High energy muon colliders, such as the TeV-scale conceptual designs now being considered, are found to produce enough high energy neutrinos to constitute a potentially serious off-site radiation hazard in the neighbourhood of the accelerator site. A general characterization of this radiation hazard is given, followed by an order-of-magnitude calculation for the off-site annual radiation dose and a discussion of accelerator design and site selection strategies to minimize the radiation hazard.
Correlation characteristics of quantum noise on the shadow radiation image (RI) of the object under nondestructive testing are studied. Mathematical model of RI occasional distortions is derived. The model takes into account the parameters of object under testing and of radiation beam by radiation quanta flux density. The results obtained can be used as a component in the process of investigation of various radiation testing systems
Coherent oscillator radiation is considered. A comparison is made with classical particle radiation with gauss distribution. Decay probability for coherent state in spontaneous radiation is estimated. The method suggested for describing harmonic oscillator allows to separate the effect of classical field radiation from quantum description of particle state within the framework of a self-consistent quantum mechanical problem.
Abstract Background: Aution Max AX-4030, a test strip analyzer recently introduced to the market, represents an upgrade of the Aution Max AX-4280 widely employed for urinalysis. This new instrument model can allocate two different test strips at the same time. In the present study the two instruments have been compared together with the usage of Uriflet 9UB and the recently produced Aution Sticks 10PA urine strips, the latter presenting an additional test area for the measurement of urinary creatinine. Methods: Imprecision and correlation between instruments and strips have been evaluated for chemical-physical parameters. Accuracy was evaluated for protein, glucose and creatinine by comparing the semi-quantitative results to those obtained by quantitative methods. The well-known interference effect of high ascorbic acid levels on urine glucose test strip determination was evaluated, ascorbic acid influence was also evaluated on protein and ...
A new type of radiation which occurs when particles are accelerated in the field of a longitudinal wave and in a transverse magnetic field is studied. The characteristics of such spontaneous radiation are obtained, and the influence of collective effects on the radiation is analyzed. The application of the findings to the theory of free electron lasers is discussed. 8 references.
Objectives To provide direct estimates of risk of cancer after protracted low doses of ionising radiation and to strengthen the scientific basis of radiation protection standards for environmental,...Full Text Available
Forty-four patients with histologically proven Hodgkin's disease underwent initial treatment with extended-field radiation therapy. Nineteen of these patients also received combination chemotherapy....Full Text Available
Exact anatomic knowledge about the location of the gonads and the application of corresponding measures of radiation protection are the preconditions for an efficient reduction of the danger of a possible genetic damage as a result of radiation exposition during X-ray examination of the hip joint of newborns. (VJ).
Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available
Analytical method of theoretical simulation of collective hydrodynamic instabilities of intensive flows of discrete radiators, interacting with each other only through the coherent fields of their spontaneous radiation in corresponding media was suggested...
... Top of page Testing Radiation coming from granite countertops results from natural radioactive material in the granite. Identifying the presence and concentration of radioactive elements in granite requires expensive and sophisticated portable instruments or laboratory equipment. These instruments and equipment require proper calibration, and interpretation of ...
The different radiation loads caused by natural and artificial radionuclides are compared in this paper. This examples will serve to illustrate that the problem of population exposure to radiation can only be solved in consideration of all components and to show which effects of the radiation from natural sources are of special importance in this connexion. (orig./AK).
The problem of optimizing a horn radiator of electromagnetic waves for the reflection coefficient and the coefficient of transformation of the fundamental mode into higher order modes is solved. Optimization is performed by means of selecting a combined shape of the radiator generatrices.
An optical klystron is built in the 800 MeV electron storage ring at University of Science and Technology of China for harmonic super-radiation generation. In single bunch operation mode the repetition rate of the spontaneous radiation pulses is about 4.533 MHz, and the repetition rate of the seed laser pulses is about 3 Hz, while the radiation pulse duration is 300 ps. For measuring harmonic radiation a high on/off ratio ICCD is used as an optical switch to reject spontaneous radiation pulses of high repetition rate
The document published under A/63:46 and titled report of the scientific committee of United Nations for the study of ionizing radiations effects, gives the situation of the fifty sixth session of the committee that stood at Vienna from the 10. to 18. july 2008. In the chapter 3 of this report the writers summarize the strategic planning and the working program of the scientific committee for the period 2009-2013. They note that the committee worry about the inadequate means, particularly in personnel. The priorities for the given period will be the medical exposure of patients, the radiation levels and the effects of energy production, the exposure to natural radiation sources and the improvement of the understanding of the effects of the low doses radiation exposure. (N.C.)
This study assesses the current state of undergraduate instruction in empirical research methods in communication and offers recommendations for enhancing such instruction. Responses to an online questionnaire were received from 149 communication-related programs at four-year colleges and universities. Just over 85% of responding programs offered an empirical methods course. Although the course often covered both qualitative and quantitative methods, instruction was heavily slanted toward quantitative methods and topics common to both qualitative and quantitative inquiry. The empirical methods course was usually required for graduation, but it was typically not well integrated with the rest of the curriculum and taken late in students' undergraduate careers. Additional analyses examined st...
Fifteen quantitative bone scintigraphies were performed in an adolescent girl during the follow-up of a femoral osteogenic sarcoma treated by chemotherapy and massive allograft. Three hours after injection of the radiopharmaceutical (7.4 MBq/kg of 99mTc-MDP) bone activity was measured in the inferior limbs at several regions of interest centered on the hips, femurs (proximal, middle, distal) and proximal tibias. The variations of relative bone activities A/S (ratio of corresponding counting rates between two homologous regions in the affected A and in the healthy S limb) and of absolute bone activities (expressed in counts/pixel-second) are interpreted as a function of times during treatment. The quantitative results are discussed with regard to main phenomena influencing bone activity in this particular clinical case: bone growth, chemotherapy and neo-osteogenesis in allograft.
The Pacific white shrimp, Litopenaeus vannamei, is the most important shrimp species in volume in world aquaculture. However, in recent decades, outbreaks of diseases, especially viral diseases, have led to significant economic losses, threatening the sustainability of shrimp farming worldwide. In 2004, Brazilian shrimp farming was seriously affected by a new disease caused by the Infectious myonecrosis virus (IMNV). Thus, disease control based on rapid and sensitive pathogen detection methods has become a priority. In this study, a specific quantitation method for IMNV was developed using real-time PCR with SYBR Green chemistry and viral load of the principal target tissues of chronically infected animals was quantified. The quantitative analysis revealed that mean viral load ranged from ...
During the past three years the program has undergone a substantial revitalization. There has been no significant change in the scientific direction of this grant, in which emphasis continues to be placed on developing new or improved methods of obtaining quantitative data from radiotracer imaging studies. However, considerable scientific progress has been made in the three areas of interest: Radiochemistry, Quantitative Methodologies, and Experimental Methods and Feasibility Studies, resulting in a sharper focus of perspective and improved integration of the overall scientific effort. Changes in Faculty and staff, including development of new collaborations, have contributed to this, as has acquisition of additional and new equipment and renovations and expansion of the core facilities. 121 refs., 30 figs., 2 tabs.
To more accurately measure fluorescent signals from microarrays, we calibrated our acquisition and analysis systems by using groundtruth samples comprised of known quantities of red and green gene-specific DNA probes hybridized to cDNA targets. We imaged the slides with a full-field, white light CCD imager and analyzed them with our custom analysis software. Here we compare, for multiple genes, results obtained with and without preprocessing (alignment, color crosstalk compensation, dark field subtraction, and integration time). We also evaluate the accuracy of various image processing and analysis techniques (background subtraction, segmentation, quantitation and normalization). This methodology calibrates and validates our system for accurate quantitative measurement of microarrays. Specifically, we show that preprocessing the images produces results significantly closer to the known ground-truth for these samples.
Abstract Rationale, aims and objectives- Finding ways to incorporate disparate types of evidence into research syntheses has the potential to build a better evidence base for clinical practice and policy. Yet conducting such mixed research synthesis studies is challenging. Researchers have to determine whether and how to use adjusted and unadjusted quantitative findings in combination with each other and with qualitative findings. Methods- Among quantitative findings, adjustment for confounding, either via study design or statistical analysis, can be a considerable source of heterogeneity. Yet there is no consensus about the best way to synthesize findings resulting from different methods for addressing confounding. When synthesizing qualitative and quantitative findings, additional consid...
A clinical laboratory evaluation was conducted on the Clinitek Auto 2000, the Super Aution Analyzer and the Urotron RL9 for the determination of glucose, protein, pH, blood, ketone-bodies and bilirubin.Precision of the systems was tested using three commercial control urine materials, and reported as the percentage of times the instrument repeats a certain value. Good repeatability was obtained with all the instruments.Accuracy of the systems was evaluated by comparison with quantitative procedures, and to check agreement between methods yielding semi-quantitative and quantitative results, ranges of acceptability were defined, based on the criteria reported in a previous paper [2]. It was then found that 87.5 to 98.9% of results from the Urotron RL9 and the Clinitek Auto 2000 were acceptable. With the Super Aution Analyzer the level of agreement was apparently lower because of the higher number of concentration steps used ...
Nov 8, 2010 ... Ihring Mission 11, the radiation dosimetry measurement system functioned normally and provided data on the Earth's trapped radiation belts ...
Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available
By proposing the four-dimensional, reciprocity transformations the appropriate condition for superluminal electromagnetic Cerenkov radiation is obtained by introducing the hypothesis that tachyons possess vector energy and scalar momentum.
drical Enclosures Using a Numerical Ray Tracing Technique. NASA. TM-I02527, 1990 . Buckley, H.: Radiation from the Interior of a Reflecting Cylinder. Philos. ...
...References | Radiation Protection | US EPA This page provides links to the reference material on EPA's Radiation Protection Web site. U.S. EPA/...OAR/ORIA/Radiation Protection Division Jump to main content. Radiation Protection Contact Us Search: All EPA This Area You are here: EPA Home ... Radiation Protection References PageName Technical Users General Public Reporters Librarians Students/Teachers PROGRAMS TOPICS REFERENCES References The Reference Section provides general material that support the ...other sections of EPA's Radiation Protection Web site. You will find links within the information to related pages throughout the Radiation Protection , EPA ...
The fundamental product of tetracycline hydrochlorine gamma radiolysis was separated in its solid state. From the results of spectroscopic studies it has been established that it is des-N,N-dimethylaminotetracycline.
Turbulent premixed methane-air combustion in a cylindrical chamber is numerically simulated considering radiation effect. Reaction rates are considered as minimum rates between Arrhenius rates and eddy break up rates. A five step reduced mechanism is used. Turbulent modeling is done via standard k-{epsilon} model imposed by empirical inlet boundary conditions. Source terms of energy equation consist of reaction rates and radiation effects. The discrete ordinate method (DOM) is employed to solve the radiative transfer equation (RTE) and the weighted sum of gray gas model (WSGGM) is imposed to consider radiation effect of non-gray gases. The results indicate that in the case of turbulent combusting flows, the effect of radiation of gases can affect the temperature and species concentrations. The numerical results obtained considering radiation effect are closer to ...
Turbulent premixed methane-air combustion in a cylindrical chamber is numerically simulated considering radiation effect. Reaction rates are considered as minimum rates between Arrhenius rates and eddy break up rates. A five step reduced mechanism is used. Turbulent modeling is done via standard k-? model imposed by empirical inlet boundary conditions. Source terms of energy equation consist of reaction rates and radiation effects. The discrete ordinate method (DOM) is employed to solve the radiative transfer equation (RTE) and the weighted sum of gray gas model (WSGGM) is imposed to consider radiation effect of non-gray gases. The results indicate that in the case of turbulent combusting flows, the effect of radiation of gases can affect the temperature and species concentrations. The numerical results obtained considering radiation effect are closer to the ...
... iFfficiency-en- enhanced spontaneous radiation at the free-electron- ... as enhanced spontaneous radiation at the free-electron-laser wavelength. ...
The introduction of tolerance to radiation (''radiation-hardness'') into large electronic systems is one of the major tasks to which this Handbook will be put. The practices recommended here for inculcating radiation-tolerance in equipment require advanced physical modeling techniques, precise engineering procedures, and firm assurance procedures. The degree to which these procedures should be used in an equipment project can be measured by the severity of the raw radiation environment, the desired reliability of the system, and the requirement of that project for radiation-sensitive technologies. The balance of device/circuit design versus shielding will depend on whether the radiation is highly penetrating -- as in isotope handling or military environments -- or readily attenuated, as in space. In this chapter the authors have attempted to summarize the ...
When energetic bunches of electrons traverse an undulator field, they can spontaneously emit radiation both coherently and incoherently. Although it has generally been assumed that undulator radiation is incoherent at wavelengths short compared to the longitudinal size of the electron bunch, several recent observations have proved this assumption false. Furthermore, the appearance of coherent radiation is often accompanied by a significant increase in radiated power. Here we report observations of strongly enhanced coherent spontaneous radiation together with direct measurements, using transition radiation techniques, of the electron distributions responsible for the coherent emission. We also report demonstrated enhancements in the predicted spontaneous radiated power by as much as 6x10"4 using electron bunch compression. copyright 1996 ...
... Except for isolated radiation accidents over the ensuing years, little practical experience has been gained in the treatment of thermal injuries ...
... spontaneous radiation of amplifiers within a relatively w~de range of ... pulse widths are 20-30ns, while amplified spontaneous radiation pulse ...
BackgroundA common approach to understanding the genetic basis of complex traits is through identification of associated quantitative trait loci (QTL). Fine mapping QTLs requires...Full Text Available
In proteomics, one-dimensional (1D) SDS-PAGE is widely used for protein fractionation prior to mass spectrometric analysis to enhance dynamic range of analysis and to improve identification...Full Text Available
A comparative and quantitative study of the tissue distribution of brain-thymus shared antigens was carried out using rabbit antisera to rat, dog and human brain homogenates, assayed on rat, dog and...Full Text Available
SummaryIn vivo tumor cell migration through integrin-dependent pathways is key to the metastatic behavior of malignant cells. Using quantitative in vivo...Full Text Available
Neuroblasts born in the adult subventricular zone (SVZ) migrate long distances in the rostral migratory stream (RMS) to the olfactory bulbs where they integrate into circuitry as functional interneurons....Full Text Available
In order to maintain a safe operation and availability of generating facilities, qualitative and quantitative assessment of piping vibration was performed vibration sources and damages of piping support was identified on the second piping system of Wolsun...
Neutron radiography (NR) is a useful non-destructive method for determination of hydrogen content in various building and technical materials. Monitoring of transport processes of moisture and hydrogenous liquids in porous building materials is enabled by fast, quasi-real-time NR methods based on novel imaging plate neutron detectors (IP-NDs). Hydrogen content in the samples is determined by quantitative analysis of measured profiles of neutron attenuation in the samples. Detailed description of quantitative NR method is presented by the authors in another accompanying contribution at this conference. Deterioration of building materials is originated by different processes that all require presence of water therefore it is essential to limit or prevent the transport of water through the porous material. In this presentation, results of a study of clay brick impregnation by silicone based hydrophobic agents will be presented. ...
The quantitative experimental uncertainty in the structure of fully hydrated, biologically relevant, fluid (Lα) phase lipid bilayers has been too large to...Full Text Available
An antigen-antibody system of polystyrene tubes coated with immunoglobulin antibody was used for quantitating immunoglobulins. A similar radioimmunoassay method was adapted for a viral antigen-antibody...Full Text Available
French ... Orig. Title Scintigraphie osseuse quantifiee chez l'enfant et l'adolescent - repartition selon l'age des taux de fixation de diverses pieces osseuses normales.
Thirty-four patients with prostatic carcinoma were studied with quantitative bone scintigraphy and whole-body counting (WBC) 1 and 24 h after injection of [sup 99m]Tc-MDP before as well as two weeks and two months after orchiectomy. Thirteen of the patients had normal bone scintigrams and WBR at the three different investigations; 21 had skeletal metastases. The latter showed throughout the study higher local gamma camera count rates as well as WBR values than the patiens with normal scintigrams. In these patients a ''flare phenomenon'', with an increase in count rate two weeks after orchiectomy followed by a decrease two months post-operatively, was seen with quantitative bone scintigraphy but not with WBC. However, WBC may be a valuable method indicating the total extent of skeletal metastases in the body, while quantitative bone scintigraphy is more accurate in the interpretation of ...
Thirty-four patients with prostatic carcinoma were studied with quantitative bone scintigraphy and whole-body counting (WBC) 1 and 24 h after injection of "9"9"mTc-MDP before as well as two weeks and two months after orchiectomy. Thirteen of the patients had normal bone scintigrams and WBR at the three different investigations; 21 had skeletal metastases. The latter showed throughout the study higher local gamma camera count rates as well as WBR values than the patiens with normal scintigrams. In these patients a ''flare phenomenon'', with an increase in count rate two weeks after orchiectomy followed by a decrease two months post-operatively, was seen with quantitative bone scintigraphy but not with WBC. However, WBC may be a valuable method indicating the total extent of skeletal metastases in the body, while quantitative bone scintigraphy is more accurate in the interpretation of individual skeletal metastases. (orig.).
Background In May 2000, AstraZeneca launched a Web service for asthma patients and health-care providers called LinkMedica, which includes an asthma diary for...Full Text Available
1. A combined pharmacokinetic-pharmacodynamic model has been used to analyse the relationship between QT prolongation and changes in plasma concentration which occurred after disopyramide was given...Full Text Available
Forty-six patients with end-stage renal failure were subjected to iliac crest biopsy before the initiation of a dialysis programme and regardless of the presence of skeletal symptoms....Full Text Available
Striped bass (Morone saxatilis) in the Chesapeake Bay are currently experiencing a very high prevalence of mycobacteriosis associated with newly described Mycobacterium...Full Text Available
Binding of epidermal growth factor (EGF) to the EGF receptor (EGFR) initiates signal transduction, ultimately leading to altered gene expression. Ligand-activated EGFR is also rapidly internalized...Full Text Available
In a Swedish community-based program for the treatment of dental phobic patients, a clinical trial was performed among 99 severely phobic individuals with long-standing avoidance of dental treatment....Full Text Available
A quantitative trait locus (QTL) analysis designed for a multi-parent population was carried out and tested in oil palm (Elaeis guineensis Jacq.), which is a diploid cross-fertilising...Full Text Available
We report the first quantitative assessment of electrosprayed droplet/ion focusing enabled by the use of a voltage-assisted air amplifier between an electrospray ionization emitter and a hybrid...Full Text Available
How transcription factors interpret the cis-regulatory logic encoded within enhancers to mediate quantitative changes in spatiotemporally restricted expression patterns during animal...Full Text Available
Dissecting the genes involved in complex traits can be confounded by multiple factors, including extensive epistatic interactions among genes, the involvement of epigenetic regulators, and the variable...Full Text Available
The A(..pi../sup +/,/sup 3/He)B reaction near threshold is studied in a model where the pion is absorbed by an /sup 4/He constituent of the target nucleus. The predictions of this model using harmonic oscillator cluster wave functions agree semi-quantitatively with the experimental data on the inverse reaction.
This study investigated weathering effects on polyvinyl chloride (PVC) based wood plastic composites (WPC), with a focus on the color and structure that is attributed to the material composition. It is directed towards quantifying the main chemical modifi...
Recent experiments have provided new quantitative measurements of the rippling phenomenon in fields of developing myxobacteria cells. These measurements have enabled us to develop a mathematical model...Full Text Available
Aims:To Study the religious and ideological views and practice of Palliative Care physician towards Euthanasia.Materials and Methods:An...Full Text Available
Skeletal radiotracer (sup(99m)Tc-HEDP) uptake was quantitated with and without the aid of a computer in 30 chronic dialysis patients with histologic evidence of renal osteodystrophy. Before scintigraphy, elevated soft-tissue activity due to the absence of renal radiotracer excretion was reduced by hemodialysis. The results were compared with those of a normal group and with the results of the biochemical and the bone morphometric studies of these patients. In all patients the radiotracer uptake was elevated, often markedly. In several patients with minimal histologic bone disease, however, soft-tissue activity could not be normalized by hemodialysis although its influence on the quantitative data could be further reduced (but not excluded) by computer evaluation of skeletal radiotracer uptake. Since the latter technique clearly distinguished the majority of the patients from the normals, it appears that computerized ...
Skeletal radiotracer (sup(99m)Tc-HEDP) uptake was quantitated with and without the aid of a computer in 30 chronic dialysis patients with histologic evidence of renal osteodystrophy. Before scintigraphy, elevated soft-tissue activity due to the absence of renal radiotracer excretion was reduced by hemodialysis. The results were compared with those of a normal group and with the results of the biochemical and the bone morphometric studies of these patients. In all patients the radiotracer uptake was elevated, often markedly. In several patients with minimal histologic bone disease, however, soft-tissue activity could not be normalized by hemodialysis although its influence on the quantitative data could be further reduced (but not excluded) by computer evaluation of skeletal radiotracer uptake. Since the latter technique clearly distinguished the majority of the patients from the normals, it appears that computerized ...
Based on a generalized theory of perturbations and on non-linear programming an approach to the quantitative determination of necessary accuracies for nuclear data is described. It is used to calculate transactinide isotope build-up in reactors.
BackgroundPlant biologists have long speculated about the mechanisms that guide pollen tubes to ovules. Although there is now evidence that ovules emit a diffusible attractant, little...Full Text Available
BackgroundArtemisinin-based combination therapy, currently considered the therapy of choice for uncomplicated Plasmodium falciparum malaria in endemic countries,...Full Text Available
The localization of gold in the synovial membrane of rheumatoid arthritis patients treated with sodium aurothiomalate was examined and quantitative analysis of epon-embedded sections was carried out...Full Text Available
A fluid-phase immunoradiometric assay has been developed which identifies an antigen on the Factor VIII (antihemophilic factor) procoagulant protein. This sensitive and quantitative assay is not influenced...Full Text Available
A novel, quantitative method for detecting poly-3-hydroxybutyrate (PHB) amounts in viable cells was developed to allow for high-throughput screening of mutant libraries. The staining technique was demonstrated...Full Text Available
Our increasing capabilities for quantitative hormone analysis and automated high resolution growth studies have allowed a reassessment of the classical Cholodny-Went hypothesis of gravitropism. According...Full Text Available
BackgroundThe decline noticed in several fertility traits of dairy cattle over the past few decades is of major concern. Understanding of the genomic factors underlying fertility,...Full Text Available
Quantitative probing of heterogeneous regions in muscle is feasible with phosphorus-31 magnetic resonance spectroscopy because of the differentiation of metabolic patterns of glycolytic and oxidative...Full Text Available
The changes in conjugated indole-3-acetic acid (IAA) levels compared to the levels of free IAA have been analyzed during the development of bean (Phaseolus vulgaris L.) seed using quantitative...Full Text Available
Studies were conducted to quantitate the evolution of nitrogen oxides (NO(x)) from soybean [Glycine max (L.) Merr.] leaves during in vivo nitrate reductase...Full Text Available
Pseudomonas mandelii liquid cultures were studied to determine the effect of pH and temperature on denitrification gene expression, which was quantified by quantitative reverse transcription-PCR....Full Text Available
A liquid chromatography/tandem mass spectrometric (LC/MS/MS) assay was developed for the quantitative determination of salirasib (S-trans, trans-farnesylthiosalicylic acid,...Full Text Available
Experimental and imaging studies in monkeys have outlined various long association fiber bundles within the temporoparietal region. In the present study the trajectory of the middle longitudinal fascicle...Full Text Available
Qualitative and quantitative aspects of the mechanisms involved in the regulation of cytoplasmic pH during an acid-load have been studied in Acer pseudoplatanus cells. Two main processes,...Full Text Available
Motivation: Cell tracking is an important method to quantitatively analyze time-lapse microscopy data. While numerous methods and tools exist for tracking cells in 2D time-lapse images,...Full Text Available
Quantitative metallography is often used to confirm the proper processing of aerospace metallic materials. A microstructural feature of great importance for titanium alloys processed in the alpha-beta phase field is the volume fraction of primary alpha. S...
Activatable or “smart” magnetic resonance contrast agents have relaxivities that depend on environmental factors such as pH or enzymatic activity, but the MR signal depends on...Full Text Available
A bedload trap in the riverbed provided direct quantitative measurement of debris-transport rate in the East Fork River, Wyoming, a basin of 466 km2 drainage area. Traction load moves only...Full Text Available
The purpose of the work was to quantitatively characterize temperature effects on the bacterial leaching of sulfide ore material containing several sulfide minerals. The leaching was tested at eight...Full Text Available
BackgroundKinematic and kinetic measurements used in laboratory settings can quantify upper extremity movement impairment following stroke, but their relationship...Full Text Available
We used tryptophan auxotrophs of the dicot Arabidopsis thaliana (wall cress) to determine whether tryptophan has the capacity to serve as a precursor to the auxin, indole-3-acetic acid (IAA). Quantitative...Full Text Available
In nuclear fuel with a burn-up of 33 kg/t U and 52 kg/t U 15 transuranium nuclides /sup 237/Np to /sup 246/Cm have been determined by alpha and gamma spectroscopy after radiochemical separation.
BackgroundQuantitative sensory testing (QST) is applied to evaluate somatosensory nerve fiber function in the spinal system. This study uses QST in patients with sensory dysfunctions...Full Text Available
Arbuscular mycorrhizal fungi (AMF) are obligate biotrophs, known to play an important role in ecological processes. Conventional light microscopy is the most common method used to detect their presence...Full Text Available
Numbers of non-indigenous species--species introduced from elsewhere - are increasing rapidly worldwide, causing both environmental and economic damage. Rigorous quantitative risk-analysis frameworks,...Full Text Available
The 52 papers discuss the following subjects: 1. Preparation and structural development; 2. Structural constitution; 3. Structural formation and phase transition; 4. Structure and mechanical properties; 5. Structural formation of metallic and nonmetallic materials; 6. Quantitative metallography, and 7. Quality assurance.
DNA antoantibodies in serum will bind to antigen-coated polystyrene tubes and can be detected by radiolabelled anti-immunoglobulin. The method is quantitative, gives information on the antibody class...Full Text Available
BackgroundCerebral malaria (CM) is a neurological syndrome that includes coma and seizures following malaria parasite infection. The pathophysiology is not fully understood and cannot...Full Text Available
There has been increased theoretical and experimental research interest in autonomous mobile robots exhibiting cooperative behaviour. This paper provides consistent quantitative measures of organizational degree of a two-dimensional environment. We proved, by the way of numerical simulations, that the theoretically derived values of the feature are reliable measures of aggregation degree. The slope of the feature's dependence on memory radius leads to an optimization criterion for stochastic functional self-organization. We also described the intellectual heritages that have guided our research, as well as possible future developments. (author)
An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.
An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.
A technique for quantitative analysis of growth plates in varus or valgus deformity about the knee has been developed. Computer-generated regions of interest are placed on magnification scintigraphs to divide distal femoral and proximal tibial physes into four equal segments. The ratio of counts in the medial half to counts in the lateral half was studied in 31 children (22 normal, 9 with angular deformity). Normal ratios were 0.74 to 0.98 for femora and 0.98 to 1.20 for tibias. In eight of nine patients with deformity, the ratio was abnormal; in two patients the ratio returned to normal when the deformity ceased to progress.
The authors experimentally study the separate stages of the determination of iodine in thyroidin by the combustion method in a flask with oxygen. The monotypic, conventional procedures and the procedure of Kolii and Pakhomov were studied. With addition of potassium iodide, a sixfold amount (compared with the initial) of iodine is liberated. Further, the liberated iodine is titrated by sodium thiosulfate. The authors find the degree of influence of a high nitrogen content on the determination of iodine in organic compounds. The procedure developed for the quantitative determination of the iodine in thyroidin by the combustion method is simple, fairly rapid, and can be used for the reliable control of the quality of thyroidin preparations and its starting raw material.
The ultimate compressive strength of 36 thoracolumbar vertebrae was determined experimentally. In addition, the trabecular bone mineral content was measured by single energy quantitative computed tomography. The areas of fractured endplates were also determined by computed tomography. The results show that a linear relationship exists between the compressive strength and the product of bone density and endplate area. These data allow an in vivo prediction of vertebral body strength using a noninvasive method with a standard error of estimate amounting to less than 0.95 kN. PMID:3212488
The investigation of the petroleum contamination in marine organisms requires the trace level quantitative determination of indicative substances to be identified by a fingerprint of petroleum. Polymethylnaphthalene (PMN) and polymethylphenanthrene (PMP) were chosen because of their simple separation from a crude oil by means of an activated charcoal chromatography, their relatively high existence in aromatic compounds, and their persistence relative to other petroleum components in the tissue of oil contaminated marine organisms. The purpose of this paper is to present an activated charcoal chromatographic separation procedure of PMN and PMP in a crude oil and a trace level quantitative analytical method of them in marine organisms by mass fragmentography (MF).
This paper is aimed to present a fuzzy decision making approach to deal with the performance measurement in supply chain systems. In the manufacturing environment, performance measurement is based on different quantitative and qualitative factors. Some of these factors may have a larger effect on the performance measure than others. Units of measure of the quantitative factors are different such as time, money, percentage, ratio, and counts. Thus, this paper presents a performance measurement approach based on fuzzy set theory and the pair-wise comparison of Analytical Hierarchy Process (AHP), which ensures the consistency of the designer's assignments of importance of one factor over another to find the weight of each of the manufacturing activity in the departmental organization. In the ...
Sixteen patients with PAGET's disease of bone underwent quantitative bone scintigraphy with "9"9"mTc-MDP before and after a long-term treatment with carbocalcitonin, a synthetic analogue of eel calcitonin. The radionuclide study consisted in the blood pool and bone uptake measurement and in the bone avidity calculation (bone uptake - blood pool ratio). In our patients, a significant decrease in bone uptake and bone avidity was found, whereas the blood pool remained statistically unchanged. This behaviour could be accounted for the shift of the compact bone to a lamellar pattern. (orig.).
Sixteen patients with PAGET's disease of bone underwent quantitative bone scintigraphy with /sup 99m/Tc-MDP before and after a long-term treatment with carbocalcitonin, a synthetic analogue of eel calcitonin. The radionuclide study consisted in the blood pool and bone uptake measurement and in the bone avidity calculation (bone uptake - blood pool ratio). In our patients, a significant decrease in bone uptake and bone avidity was found, whereas the blood pool remained statistically unchanged. This behaviour could be accounted for the shift of the compact bone to a lamellar pattern.
The objective of Configuration Risk Management Program(CRMP) is to maintain the safety level by assuring the defense-in-depth of nuclear power plant while the configurations are changed during plant operations, especially for the LP/SD. Such a safety purpose can be achieved by establishing the risk monitoring programs with both quantitative and qualitative features. Generally, the quantitative risk evaluation models, i.e., PRA models are used for the risk evaluation during full power operation, and the qualitative risk evaluation models such as safety function assessment trees are used. Through this study, safety function assessment trees were developed.
The following topics are discussed: insertion of incorrect bases in DNA; ability of DNA polymerase to copy uv-irradiated DNA; role of enzymes in repair of DNA; effects of uv radiation on molecular weight of DNA; photoreactivation; repair of DNA in Escherichia coli and xp cells following uv radiation; and synchrotron radiation studies on DNA repair. (HLW)
The book is divided into two approximately equal parts. The first four chapters are relatively lengthy and cover the basic principles of radiation biology, carcinogenesis and therapy, along with a brief introduction to radiological physics to orient the reader without background in this specialized related discipline. The remainder consists of twenty-four relatively brief chapters, each covering the radiation biology of a specific organ, tissue, or systems tissues, with emphasis on the tumorigenic and tumoricidal action of ionizing radiations.
The present state of knowledge on the influence of stray radiation on image quality and its physical description and quantification is summarized. Experimental results on the influence of physical parameters on the fraction of scattered radiation and the effect of scatter reduction by air gap technique and secondary radiation grids are committed. Open theoretical and practical problems and the limitations of common methods of scatter reduction are pointed out. (author).
Disclosed herein is a radiation detector providing for the in situ automatic sampling of fluids containing substances emitting radiation, especially Cerenkov radiation. The detector permits sampling within well casings and is self-purging such that no additional provisions must be established for the storage and disposal of contaminated fluids.
A study is made of the mechanical properties of vanadium irradiated with fast neutrons up to dose 8.6.10"-"4 dpa, as a function of the temperature of post-radiation annealing. The radiation-annealing hardening (RAH) effect is observed at 300"oC, in agreement with previous studies. It is established for the first time that RAH is accompanied by fall in ductility. A phenomenological model is described which explains the dependence of RAH on radiation dose and temperature, as well as on the content of chemically active alloying impurities. (author).
A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.
A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.
A formula is obtained which describes the kinetics of low-temperature radiation hardening caused by creation of dislocation loops of interstitial type during irradiation. The radiation hardening of aluminum and vanadium is estimated using this formula and results of experiments on studying processes of nucleation and growth of interstitial dislocation loops in these materials by transparent electron microscopy. It is shown that the proposed formula is valid for description of the kinetics of low-temperature radiation hardening.
In scattering of channeled particles by point defects and in emission of gamma rays in the spontaneous-radiation spectral region conditions are attained where the momentum transferred to the defect is taken up by the crystal as a whole. This leads to coherent and interference effects in the radiation from the crystal defects. When the longitudinal momentum transferred is zero, an induced radiation effect appears in the transitions between the states of transverse motion.
External radiation dose exceeded 5,000 rad in three cases, and intravaginal radiation dose was 5,000 rad in one case. Radiation damage including perforation was seen in the end of ileus in one case, in the sigmoid and rectum in two cases, and in the end of ileus, sigmoid and rectum in the last case. Satisfactory results were obtained by the removal of the ileocecum in the case of the damage in the end of the ileus. However, only colostomy was performed for the damage in the sigmoid and rectum.
Due to the intensity and vast number of subjects, this Bremen experts' discussion, too, could discuss only part of the problem of the possibilitiy to quantify the radiation hazard. One preliminary result is that there is no scientific proof of the harmlessness of radiation exposure during normal operation of a nuclear power plant, either within the plant or in its vicinity. Other results are that some important questions can not be answered yet, and that there are important hints on the dangers even of low radiation doses. (GL).
In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)
In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)
The total radiation rate, angular distribution of the emitted energy and photon correlations of the cooperative spontaneous radiation from two atoms with different resonance frequencies and spontaneous decay rates are calculated. Contrary to the case of two identical atoms oscillations appear in the total radiation rate and the spatial distribution of the total number of emitted photons differs from the single-atom radiation pattern. The effect of the dipole-dipole near-field interaction on the time evolution of the atomic system is discussed. (author).
BackgroundTo compare two strategies of dynamic intensity modulated radiation therapy (dIMRT) with 3-dimensional conformal radiation therapy (3DCRT) in the setting of hypofractionated...Full Text Available
Results on defect structure study and degree of molybdenum radiation hardening irradiated by fission neutrons and medium energy alpha-particles are presented. It is shown that molybdenum irradiation by alpha-particles and neutrons leads to different degree of material hardening for the same damage level. It is established that molybdenum radiation hardening is mainly defined by radiation defect clusters visible in electron microscope whose coefficient of rigidity depends on their size. 5 refs.; 6 figs.; 2 tabs. (author).
We formulate a complete theory of Edge Radiation based on a novel method relying on Fourier Optics techniques. Similar types of radiation like Transition Undulator Radiation are addressed in the framework of the same formalism. Special attention is payed in discussing the validity of approximations upon which the theory is built. Our study makes consistent use of both similarity techniques and comparisons with numerical results from simulation. We discuss both near and far zone. Physical understanding of many asymptotes is discussed. Based on the solution of the field equation with a tensor Green's function technique, we also discuss an analytical model to describe the presence of a vacuum chamber. In particular, explicit calculations for a circular vacuum chamber are reported. Finally, we consider the use of Edge Radiation as a tool for electron beam diagnostics. We discuss Coherent Edge ...
The influence of a periodic electromagnetic field on the radiative corrections to the atomic energy levels is studied for the case of ''strong fields'' for which the interaction between the atom and field is of the order or greater than the radiative effects. The analysis is carried out on the basis of the Schwinger-Dirac equation for the propagation function of a bound electron in the field and on the basis of the density matrix in the Furry representation. It is shown that in the strong field approximation the radiative shifts and widths are manifest as radiative corrections to the quasi-energies. In super-high resolution experiments intensity effects in the radiative corrections to the atomic levels are obtained in the case of single-photon resonance. Some multiphoton processes are condidered by taking into account the effect of the field on ...
The stages of processes leading to radiation damage are studied, as well as, the direct and indirect mechanics of its production. The radiation effects on nucleic acid and protein macro moleculas are treated. The physical and chemical factors that modify radiosensibility are analysed, in particular the oxygen effects, the sensibilization by analogues of nitrogen bases, post-effects, chemical protection and inherent cell factors. Consideration is given to restoration processes by excision of injured fragments, the bloching of the excision restoration processes, the restoration of lesions caused by ionizing radiations and to the restoration by genetic recombination. Referring to somatic effects of radiation, the early ones and the acute syndrome of radiation are discussed. The difference of radiosensibility observed in mammalian cells and main observable alterations in tissues and ...
The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. ...
The atomic explosions in Hiroshima and Nagasaki made the name radiation itself become a nightmare. Notwithstanding this, radiation continued to serve the mankind specially in diagnosis of several human diseases and in the treatment of intractable malignancies. With their latest research tools biologists have now shown a significant shift in the earlier paradigm; even the concept that radiation initiates cancer appears to be no longer tenable. On the contrary, selective radiation doses inhibit growth of cancer cells and radiation in combination with many chemotherapeutic drugs, radiosensitizing chemicals and/or hyperthermia, is emerging as a new modality for cancer treatment which offers high therapeutic advantages. In addition, the deleterious effects of radiation can now be strategically counter poised by the use of many drugs and chemicals. This has been ...
Background: The difficulty of directly measuring cellular dose is a significant obstacle to application of target tissue dosimetry for nanoparticle and microparticle toxicity assessment. As a consequence, the target tissue paradigm for dosimetry and hazard assessment of nanoparticles has largely been ignored in favor of using metrics of exposure (e.g. ?g particle/mL culture medium, particle surface area/mL, particle number/mL). We have developed a computational model of solution particokinetics (sedimentation, diffusion) and dosimetry for non-interacting spherical particles and their agglomerates in monolayer cell culture systems. Particle transport to cells is calculated by simultaneous solution of Stokes Law (sedimentation) and the Stokes-Einstein equation (diffusion). Results: The In vitro Sedimentation, Diffusion and Dosimetry model (ISDD) was tested against measured transport rates or cellular doses for multiple sizes of polystyrene spheres (20-1100 nm), 35 nm amorphous silica, ...
Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).
Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).
The emission of Cerenkov radiation by tachyons has been examined by using the reduced expansions of superluminal electromagnetic fields in terms of standard helicity representation of Poincare group. It has been shown that the tachyons emit Cerenkov radiation through their coupling only with subluminal electromagnetic fields and that a charged tachyon can emit Cerenkov radiation only in the media in which it travels with a velocity lower than that of light while in the usual medium in which its velocity is more than that of light, it will never emit Cerenkov radiation. (author).
Standard radiation monitoring has been conducted at Sendai nuclear power station for the purpose of estimation of 'source activity' during refueling outage and evaluation of countermeasures to reduce dose rate. Selected objects of the monitoring are radiation dose rate at maintenance area, radiation field at each equipment and piping, coolant chemistry and plant operation condition. Monitored data indicates that 'source activity' variation can be estimated to some extent using influential factors, and that evaluation of change of loose crud activity, which is presumed to be represented by the dose rate at letdown heat exchanger, is necessary to further explain change in radiation field at main work area. (author).
The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.
The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).
The diffusion coefficient of particles in radioactive gases has been calculated with account of random wandering of aerosols (occurrence of local fields affecting the particles; recoils accompanying radiation emitted by particles, etc.). To determine the diffusion coefficient, the method of Fokker-Planck equation derivation was used. A formula is presented for calculating the radiation-stimulated diffusion coefficient. A linear growth of the diffusion coefficient with radioactivity is noted according to the formula, the diffusion coefficient is mainly determined by the field in the radiation damage region. The aerosol radioactivity may result in a more rapid deposition of aerosols in the pipelines and aerosol purification systems. The diffusion rate grows not only in the presence of intrinsic radioactivity but in case of external radiation exposure as well.
The results of theoretical and experimental investigations, describing the effect of ionizing radiation on wood and its main components and methods for production of wood-plastic composites by means of radiation-induced chemical modification are generalized. Domestic and foreign experience in their production is systematized; physico-mechanical characteristics of new material, simulation and calculation of irradiating devices, as well as calculation and experimental study of #gamma#-radiation attenuation both by wood material and by wood of different species are given. Gamma sources ("6"0Co isotope, a hot loop of a nuclear reactor) as well as electron accelerators are considered as ionizing radiation sources.
RADSOLVER is a computer program which calculates the radiation energy transport in cavity type receivers having an arbitrary number of apertures through which collimated beams of solar radiation enter. In contrast to the common assumption of gray (or semi-gray) surfaces used in the modeling of radiation transport, RADSOLVER accounts for the wavelength-dependence of emission, absorption and reflection with a band model of the radiative properties. It is intended that this report serve both as an instruction manual for the use of the RADSOLVER code and a vehicle for presenting the underlying theory. Illustrative examples along with input and output are presented.
Outage is a specific period of time for radiation protection in a nuclear power plant, in which the radiation risk and collective dose are both at the highest level. In this article, the practice and experience of occupational exposure control in the outages of Daya Bay Nuclear Power Plant are introduced through following aspects: early involvement in outage preparation by radiation protection service, control of source term, radiation protection and safety management in the outage implementation processes, the effectiveness of the plant's safety management network and overall involvement of all staffs of the plant, experience feedback and continuous improvement in radiation protection management, etc
In radiation risk assessment it must be differentiated between somatic and genetic effect on the one hand as well as between stochastic and non-stochastic effect on the other. According to definitions of the ICRP report 26 the limit for the dose equivalent of all tissues prevents non-stochastic radiation effects. With stochastic radiation effects probably exist no threshold doses; therefore the ALARA principle must be applied concerning radiation protection. The individual risk by stochastic radiation effects in its linear, linear-quadratic and quadratic extrapolations, respectively, is discussed in detail. The effective stochastic dose equivalent (H/sub eff/) as well as collective dose and collective damage are outlined.
In Korea, the Proton Engineering Frontier Project (PEFP) is building a proton linear accelerator facility with energy up to 100MeV and a beam current of 20mA. In this study, a radiation field after shutdown in the accelerator facility of the PEFP was evaluated for the purpose of the radiation shielding by using MCNPX code. A facility modeling was performed for the accelerator tunnel building, accelerator chain, target rooms and beam experiment hall. And radiation source terms were evaluated in the facility. With this facility, model and radiation source terms, the concentration of 41Ar was evaluated and the cooling time satisfying regulation in Korea was calculated.
Delayed cerebral necroses after irradiation are to be divided into hemispheric and midline lesions, as they differ from each other in several aspects. Apart from the symptoms, they are differing in the duration of latency, in the course and prognosis, and also with regard to morphology. Though there is no doubt that radiation tolerance of cerebral midline structures is relatively limited, on biological grounds, evidence of a difference between the tolerated doses could not be given from the existent inhomogeneous radiation data, with the help of the NSD-concept. Radiation planning for the region of the head, nevertheless, carefully should avoid in every case to involve the structures of the cerebral midline.
Remote-controlled handling systems are required for work to be done in the decommissioning and dismantling of nuclear facilities. These systems are equipped with electronic devices suitable for use in working environments affected by ionizing radiation. The publication explains the step-wise progress achieved for improving the radiation resistance of electronic devices with the example of a four-quadrant controlling device for the motors of a manipulator. The radiation resistance of the device could be enhanced to radiation energies of 5.500 Gy. This means that a manipulator vehicle equipped with this controlling device can take up to approx. 15 kGy all in all, taking into account its own shielding properties. (DG).
Investigations were carried out of radiation level around Daya Bay for three times since the construction and operation Daya bay Nuclear Power Station and Lingao Nuclear Power Station in Guangdong province in the period of 1988 to 2000. As shown by the investigation, the radiation levels both in the field and indoors remains unchanged by and large but slightly higher than before on the roads. Also this paper gives the analysis of variations in radiation levels form site to site and from time to time. It was shown that, for environmental ? radiation levels measurements, typical measuring sites have significant impact on the meaning results. (authors)
The work scope of 'Biological Research for the Radiation Protection' had contained the research about ornithine decarboxylase and its controlling proteins, thioredoxin, peroxiredoxin, S-adenosymethionine decarboxylase, and glutamate decarboxylase 67KD effect on the cell death triggered ionizing radiation and H_2O_2(toxic agents). In this study, to elucidate the role of these proteins in the ionizing radiation (or H_2O_2)-induced apoptotic cell death, we utilized sensesed (or antisensed) cells, which overexpress (or down-regulate) RNAs associated with these proteins biosynthesis, and investigated the effects of these genes on the cytotoxicity caused by ionizing radiation and H_2O_2(or paraquat). We also investigated whether genisteine(or thiamine) may enhance the cytotoxic efficacy of tumor cells caused by ionizing radiation (may enhance the preventing effect ...
Spontaneous radiation emitted from relativistic electrons undergoing betatron motion in a plasma-focusing channel is analyzed, and applications to plasma wake-field accelerator experiments and to the ion-channel laser (ICL) are discussed. Important similarities and differences between a free electron laser (FEL) and an ICL are delineated. It is shown that the frequency of spontaneous radiation is a strong function of the betatron strength parameter a(beta), which plays a role similar to that of the wiggler strength parameter in a conventional FEL. For a(beta) > or approximately 1, radiation is emitted in numerous harmonics. Furthermore, a(beta) is proportional to the amplitude of the betatron orbit, which varies for every electron in the beam. The radiation spectrum emitted from an electron beam is calculated by averaging the single-electron spectrum over the electron distribution. This leads to a ...
The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation doses absorbed within the critical organs - red bone marrow, lung, thyroid gland and female breast - and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. projection, the use of an abdominal compression device and ...
The incidence of hilar cholangiocarcinoma is very rare worldwide. Radical resection is the only prognostic factor for long survival in patients with hilar cholangiocarcinoma. Postoperative radiation therapy can improve local control and survival rates for patients with palliative resection, but it remains controversial in patients with radical resection. Biliary drainage can effectively release bile duct obstruction for the majority of patients with locally advanced disease, and may even prolong survival when combined with radiation therapy. Radiation therapy includes extrernal beam therapy alone, external beam therapy with intraluminal brachytheapy and new radiation technique, such as three dimentional conformal therapy and intensity modulated radiation therapy. The propective randomized clinical study is needed for further investigation in the role of combined modality therapy ...
The purpose of the invention is to improve a radiation receiver, consisting of a hollow body with an opening for the entry of radiation and a ceramic absorber situated in the hollow body, which absorbs the radiation energy entering through the opening, and emits it as thermal radiation to a heat medium, so that a higher efficiency can be achieved. According to the invention, the problem is solved by the fact that the absorber consists of ceramic material on the side towards the solar radiation, which has a low emission value and a high absorption value, and that the side of the absorber towards the heat medium has ceramic material of high emission value and low absorption value. This ensures that reradiation is prevented near the opening of the hollow body, and that the solar energy entering is largely absorbed in the hollow body.
Microprocessor based ''smart'' pressure, level, and flow transmitters were tested to determine the radiation hardness of this class of electronic instrumentation for use in reactor building applications. Commercial grade Complementary Metal Oxide Semiconductor (CMOS) integrated circuits used in these transmitters were found to fail at total gamma dose levels between 2500 and 10,000 rad. This results in an unacceptably short lifetime in many reactor building radiation environments. Radiation hardened integrated circuits can, in general, provide satisfactory service life for normal reactor operations when not restricted to the extremely low power budget imposed by standard 4--20 mA two-wire instrument loops. The design of these circuits will require attention to vendor radiation hardness specifications, dose rates, process control with respect to radiation hardness factors, and ...
The invention refers a procedure of radiation dose control in irradiated tissues during electron-beam therapy. It aims at meeting the planned radiation dose for diseased tissues and taking care of the healthy ones. Therefore, the dose distribution required is determined before irradiation in consideration of such factors as energy-dependence of detector sensitivity, self-absorption within the tissue, and relative biological effectiveness. Furthermore, the expected intensity distribution of secondary quantum radiation excited in the irradiated tissue is calculated. A radiation detector for local resolution is used for registration. During irradiation the calculated intensity distribution is compared with the measured one. The invention is applicable in radiation therapy with monoenergetic electron beams.
Presented are the investigation results of electrophysical and physico-mechanical properties of KLF-20, Viksint U-4-21, Viksint KT-73, UF-7-21, KG-184, KL-4, KL-16SE-305, VIAT-1 and PPK-21 sealants, irradiated with sources of continuous and pulse #gamma#-radiation, as well as pulse #gamma#-neutron radiation. It is shown that electrophysical and physico-mechanical properties of sealants after irradiation by continuous #gamma#-radiation up to 10"6 doses and pulse gamma-neutron radiation with neutron fluence of 10"1"3 neutron/cm"2 and #gamma#-radiation dose of 10"4R do not practically change. Electric conductivity and tangent of the angle of dielectric losses increase in the process of irradiation. Electric conductivity depends on irradiation type, is proportional to dose rate and does not depend on temperature and pulse duration.
A consideration is given to the problem of selecting optimized methods of radionuclide radiation registration during the control of the objects with essential changes in thickness. Adequate model of information signal formation is developed and analyzed for the case of the existence of an inertial link of the system with the dead time of a noncontinued type. The boundary values of radiation thickness and radiation flux intensity that divide the priority of using either digital or analog registration modes are revealed. The method is found for the full correction of a systematic error of flux intensity measurement because of the dead time of the apparatus. To control the objects with essential variation of thickness the method of selective measurement of radiation intensity is proposed
Four general topics are covered in respect to the natural space radiation environment: (1) particles trapped by the earth`s magnetic field, (2) cosmic rays, (3) radiation environment inside a spacecraft, (4) laboratory radiation sources. The interaction of radiation with materials is described by ionization effects and displacement effects. Total-dose effects on MOS devices is discussed with respect to: measurement techniques, electron-hole yield, hole transport, oxide traps, interface traps, border traps, device properties, case studies and special concerns for commercial devices. Other device types considered for total-dose effects are SOI devices and nitrided oxide devices. Lastly, single event phenomena are discussed with respect to charge collection mechanisms and hard errors. (GHH)
Metal oxide semiconductor (MOS) integrated circuits, with the benefits of low power consumption, represent the state of the art technology for implantable medical devices. Three significant sources of radiation are classified as having the ability to damage or alter the behavior of implantable electronics; Secondary neutron cosmic radiation, alpha particle radiation from the device packaging and therapeutic doses(up to 70 G{gamma}) of high energy radiation used in radiation oncology. The effects of alpha particle radiation from the packaging may be eliminated by the use of polyimide or silicone rubber die coatings. The relatively low incidence of therapeutic radiation incident on an implantable device and the use of die coating leaves cosmic radiation induced secondary neutron single event upset (SEU) as the main ...
In radiation processing of food, the product often has to be prepackaged to prevent microbial recontamination during and after irradiation. The packaging material is exposed to radiation during radiation processing and radiation stability is a key consideration in the selection of packaging materials. The effects of ionizing radiation on many food packaging materials at the dose levels recommended for food precessing can be minimized by selecting appropriate radiation resistant materials. It is important to select materials in which chemicals formed as a result of the radiation treatment do not migrate and interact with the food, affecting its organoleptic and toxicological aspects. It is also important to select materials in which the physical properties are not altered to the extent they cannot resist damage during commercial production, ...
A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the detector as rays parallel to the detector axis of the detector. The collimator may be a hollow cylinder ...
Two hazard risk assessment matrices for the ranking of occupational health risks are described. The qualitative matrix uses qualitative measures of probability and consequence to determine risk assessment codes for hazard-disease combinations. A walk-through survey of an underground metalliferous mine and concentrator is used to demonstrate how the qualitative matrix can be applied to determine priorities for the control of occupational health hazards. The semi-quantitative matrix uses attributable risk as a quantitative measure of probability and uses qualitative measures of consequence. A practical application of this matrix is the determination of occupational health priorities using existing epidemiological studies. Calculated attributable risks from epidemiological studies of hazard-disease combinations in mining and minerals processing are used as examples. These historic response data do not reflect the risks associated with current ...
Quantitative bone scans were evaluated in 16 patients with osteoporosis and in a control group of 7 healthy subjects. Along with a detailed biochemical analysis of calcium-phosphorus metabolism and standartized reongenographs, a quantitative dynamic bone scintigraphy was performed according to the method proposed by the authors. The bone-accumulating factor K_b was determined on the base of mathematical analysis of the graph reflecting activity changes in bone tissue unit during the investigation, the blood-elimination factor K_h and kidney-elimination factor K_k. In addition the accumulation index AI (in %) was calculated as a relation between the activity in bone tissue unit, registered in 20 min interval, and the activity in soft tissues for the same time. Whereas the static gamma camera scintigraphy, made 3-4 hrs after injecting of the osteotrope radiopharmaceuticals, showed no specific changes in the patients examined, the method proposed ...
The effect of various forms of treatment of renal osteodystrophy was evaluated in 25 dialysis patients by quantitative bone scintigraphy, using 99m-Tc-HEDP. The results were compared with those of biochemical and bone morphometric studies. The total skeletal activity (TSA) decreased in 5 patients after transplantation, in 11 after parathyroidectomy and in 6 out of 9 treated conservatively, but did not normalize in any of the patients. Bone morphometric evaluation of treatment, which could be performed in 19 of the 20 patients who did not receive a transplant, demonstrated a reduction in the degree of hyperparathyroidism in 17 patients (89 percent). Osteoid excess was reduced in 13 patients (68 percent) but an evident reduction of osteomalacic osteoid, i.e. improvement of osteomalacia, occurred in only 4 patients (21 percent). Changes in the TSA correlated significantly with the changes in the biochemical and histological parameters of hyperparathyroidism, but not ...
The effect of various forms of treatment of renal osteodystrophy was evaluated in 25 dialysis patients by quantitative bone scintigraphy, using 99m-Tc-HEDP. The results were compared with those of biochemical and bone morphometric studies. The total skeletal activity (TSA) decreased in 5 patients after transplantation, in 11 after parathyroidectomy and in 6 out of 9 treated conservatively, but did not normalize in any of the patients. Bone morphometric evaluation of treatment, which could be performed in 19 of the 20 patients who did not receive a transplant, demonstrated a reduction in the degree of hyperparathyroidism in 17 patients (89 per cent). Osteoid excess was reduced in 13 patients (68 per cent) but an evident reduction of osteomalacic osteoid, i.e. improvement of osteomalacia, occurred in only 4 patients (21 per cent). Changes in the TSA correlated significantly with the changes in the biochemical and histological parameters of hyperparathyroidism, but ...
The diffusion of ion beam injected self-interstitials (I) and their interaction with impurities in crystalline Si has been investigated and modeled. In particular, the I-substitutional carbon (C) interactions have been studied, using a molecular-beam-epitaxy grown Si{sub 1-y}C{sub y} layer interposed between the shallow I-source and a deeper B-spike (marker for I-concentration). Substitutional C atoms are shown to trap I's, to be removed from their substitutional sites, and to form stable precipitates into the C-rich region. The I-trapping mechanism was quantitatively studied by a simulation code. The reactions causing trapping and deactivation are described. In addition, the boron markers approach was extended to the two dimensional (2D) diffusion. High resolution scanning capacitance microscopy was used for quantitative measurements of the 2D boron transient enhanced diffusion induced on a boron delta array by the I's ion ...
The diffusion of ion beam injected self-interstitials (I) and their interaction with impurities in crystalline Si has been investigated and modeled. In particular, the I-substitutional carbon (C) interactions have been studied, using a molecular-beam-epitaxy grown Si_1_-_yC_y layer interposed between the shallow I-source and a deeper B-spike (marker for I-concentration). Substitutional C atoms are shown to trap I's, to be removed from their substitutional sites, and to form stable precipitates into the C-rich region. The I-trapping mechanism was quantitatively studied by a simulation code. The reactions causing trapping and deactivation are described. In addition, the boron markers approach was extended to the two dimensional (2D) diffusion. High resolution scanning capacitance microscopy was used for quantitative measurements of the 2D boron transient enhanced diffusion induced on a boron delta array by the I's ion beam injected through a ...
The United States Air Force School of Aerospace Medicine (USAFSAM) tests the quantitative fit of masks which are worn by military personnel during nuclear, biological, and chemical warfare. Subjects are placed in a Dynatech-Frontier Fit Testing Chamber, salt air is fed into the chamber, and samples of air are drawn from the mask and the chamber. The ratio of salt air outside the mask to salt air inside the mask is called the quantitative fit factor. A motion-time study was conducted to evaluate the efficiency of the layout and work method presently used in the laboratory. A link analysis was done to determine equipment priorities, and the link data and design guidelines were used to develop three proposed laboratory designs. The proposals were evaluated by projecting the time and motion efficiency, and the energy expended working in each design. Also evaluated were the lengths of the equipment links for each proposal, and each ...
In 576 patients quantitative scintigraphy of the sacroiliac joints and the spinal cord with "9"9"mTc-pyrophosphate was performed. 328 were patients with proven ankylosing spondylitis according to the New York criteria. 120 were patients with a clinically and roentgenologically suspected ankylosing spondylitis and 128 persons formed a healthy control group. The count rate in small regions of interest (ROI) in the sacroiliac joints, the spinal cord and the os sacrum were compared on the basis of indexes. The scintigraphic data of patients with ankylosing spondylitis were compared with the healthy control group and with the radiographic findings and radiologic staging of the disease. In a longitudinal follow-up study during 1 to 6 years these investigations were continued together with clinical and roentgenological checks. Quantitative bone scintigraphy provides characteristic indexes for ankylosing spondylitis, indicating the increased mineral ...
In 620 patients quantitative bone scintigraphy with "9"9"mTc pyrophosphate of the sacroiliac joints and of the spine was performed: 365 patients with confirmed ankylosing spondylitis, 125 patients with clinical radiological suspicion for ankylosing spondylitis (probable Bechterev) and control group of 130 healthy individuals. By comparison of the activity in zones of interest of the sacroiliac joints, the spine and sacrum, the following indices were determined: sacroiliac (separately for the left and right sacroiliac joints), index D_1_0/sacrum, index L_4/sacrum and index C_7/sacrum. The scintigraphic finding was compared to the X-ray one and to the radiological stage of the disease. A long-term follow-up of the patients was carried out during 1-6 years with scintigraphic, X-ray and clinical investigations. Emphasis was laid upon the posibilities for quantitative scintigraphy for early diagnostics of ankylosing spondylitis. The combination of ...
Quantitative hepatic scintiangiography was previously used for evaluating the relative contribution of hepatic arterial and portal venous blood flows to the hepatic circulation. The present study compares 3 different procedures (automatic and manual integration, and slope fitting methods) for analyzing the hepatic time activity curves obtained after bolus i.v. injection of 370 MBq /sup 99m/Tc-diethylentriaminopentacetic acid. Twenty five subjects were studied: Five controls, ten cirrhotics, and ten portal hypertensive patients previously submitted to side to side portacaval anastomosis. The correspondence between results given by the different methods was satisfactory only in shunted patients, and the reproducibility of computed parameters was quite poor for all procedures. Accordingly, none of the methods can be considered as supporting reliable quantitative pathophysiological evaluations. However, the hepatic arterial/portal venous flow ratio ...
The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other x-ray examinations, especially computerised tomography. PMID:7134769
A brief overview if provided of selected reports presented at the International Symposium on Molecular Mechanisms of Radiation- and Chemical Carcinogen-Induced Cell Transformation held at Mackinac Island, Michigan on September 19-23, 1993.
A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.
PurposeWe conducted a comparative study of Clinical Target Volume (CTV) definition of pelvic lymph nodes by multiple GU radiation oncologists looking at the levels...Full Text Available
We show that, in addition to radiation travelling at the speed of light, QED theory predicts a second type of radiation with an infinite velocity. We also show that charge, as it appears in the Dirac equation, may have a triune nature.
Terminal-differential algorithm for identification of local nonhomogeneities in items under control is developed on the basis of measurements of X-ray or gamma-radiation weakening. The algorithm may be applied by developing radiation schemes of nondestructive control, identifying inadmissible inclusions in the object under study
To capitalize on the response of tumor cells to ionizing radiation, we developed a controlled-release nanoparticle drug delivery system using a targeting peptide that recognizes a radiation-induced...Full Text Available
The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography.
The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography. (orig.).
BackgroundMicrovascular injury plays a key role in normal tissue radiation responses. Statins, in addition to their lipid-lowering effects, have vasculoprotective...Full Text Available
This paper describes a radiation shield verification survey of a large hot cell at the Fast Flux Test Facility (FFTF). The following aspects of the shield test are discussed: description of the FFTF; description of the hot cell; the test procedures; radiation protection, and the test results.
A possible receiver configuration is a cavity in which a falling sheet of solid particles is directly irradiated by the concentrated solar flux passing through the aperture. Regardless of the particular geometry, the radiative transfer within the falling particle curtain must be studied in order to determine the net radiative heating rate for the particles. A discrete ordinate radiative transfer model has been developed to predict the radiative coupling within the falling particle curtain. The model determines how much energy is absorbed by the particles, how much is transmitted to the rear wall of the receiver, and determines the effects of particle scattering and thermal emission on the net radiation absorbed by the particles. The model accounts for the directional nature of the radiation field, particle scattering, and the wavelength dependence of the optical ...
The effect of adriamycin in combination with radiation on the skin reactions of mouse feet has been examined under a variety of experimental conditions including: (a) hyperthermic treatment of the foot immediately following adriamycin administration, with the former given either just before or just after x irradiation, and (b) fractionated treatments of drug and radiation in a variety of sequences over an 18-day period. In the case of the most severe hyperthermic treatment, no increased radiation reactions were observed in the presence of adriamycin. However, in the case of the less severe hyperthermic treatment a small but significant increase in skin reactions was observed. In the study of fractionated drug and radiation treatments, an enhancement of reaction in those animals receiving combined modality treatment over those receiving radiation alone was seen in those groups where ...
The achievements made in the field of radiation protection over the past 20 years are outlined. Risk analysis as applied to medicine is considered and genetic significant doses, genetic risks, somatic effective doses and somatic risks are discussed. (C.F.).
The in situ assembly states of the glucose transport carrier protein in the plasma membrane and in the intracellular (microsomal) storage pool of rat adipocytes were assessed by studying radiation-induced inactivation of the D-glucose-sensitive cytochalasin B binding activities. High energy radiation inactivated the glucose-sensitive cytochalasin B binding of each of these membrane preparations by reducing the total number of the binding sites without affecting the dissociation constant. The reduction in total number of binding sites was analyzed as a function of radiation dose based on target theory, from which a radiation-sensitive mass (target size) was calculated. When the plasma membranes of insulin-treated adipocytes were used, a target size of approximately 58,000 daltons was obtained. For adipocyte microsomal membranes, we obtained target sizes of approximately 112,000 and 109,000 daltons prior ...
Radiation decontamination of dry ingredients, herbs and enzyme preparations is a technically feasible, economically viable and safe physical process. The procedure is direct, simple, requires no additives and is highly efficient. Its dose requirement is moderate. Radiation doses of 3-10 kGy (0.3-1 mrad) have proved sufficient to reduce the viable counts to a satisfactory level. Ionising radiations do not cause any significant rise in temperature. The flavour, texture or other important technological or sensory properties of most ingredients are not influenced at radiation doses necessary for satisfactory decontamination, and radiation obviates the chemical residue problem. The microflora surviving radiation decontamination of dry ingredients are more susceptible to subsequent antimicrobial treatments. Recontamination can be prevented as the product can be ...
PurposeRadiation-induced heart disease (RIHD) is a severe side effect of thoracic radiotherapy. This study examined the effects of PTX and α-tocopherol on...Full Text Available
Inhibition of photosynthesis by ultraviolet-A radiation (UV-A, 315-380 nanometers) was examined in three marine angiosperms: Halophila engelmannii Aschers, Halodule wrightii...Full Text Available
Adaptive radiation is the rapid origination of multiple species from a single ancestor as the result of concurrent adaptation to disparate environments. This fundamental evolutionary process is considered...Full Text Available
An ex-employee's claims that inadequate enforcement of radiation safety regulations allowed excess radiation exposure thereby causing his deteriorating health was not substantiated by a thorough investigation.
Spontaneous radiation by an atom in a Rydberg state is inhibited by use of parallel conducting planes to eliminate the vacuum modes at the transition frequency. Spontaneous radiation emission is observed to turn off abruptly at the cutoff frequency of the waveguidelike structure, and the natural lifetime is measured to increase by a factor of at least 20.
Somatic radiation doses are recognized to be possible factors of carcinogenesis. In correctly performed mammography, however, even as screening test, the radiation dose does not reach such an order of magnitude that the benefit of the procedure as to prevention of breast cancer is called into question.
In the synthesis of the peptidyl-polymer corresponding to the sequence (57-100) of the ..beta.. chain of human hemoglobin on Teflon with radiationally grafted polystyrene a comparative study was made of different methods of fragment condensation. It was shown that the most effective methods are azide condensation and condensation with the use of complex F.
In the synthesis of the peptidyl-polymer corresponding to the sequence (57-100) of the #beta# chain of human hemoglobin on Teflon with radiationally grafted polystyrene a comparative study was made of different methods of fragment condensation. It was shown that the most effective methods are azide condensation and condensation with the use of complex F.
A method for recycling laser flashlamp radiation in selected wavelength ranges to decrease thermal loading of the solid state laser matrix while substantially maintaining the pumping efficiency of the flashlamp.
Electron spin resonance spectroscopy can provide a powerful approach to the study of radiation effects in biological materials. This memorandum gives an overview of current and future research. (author).
The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).
The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).
By using EPR measurements of radiation-induced radicals it is possible to utilize human fingernails to estimate radiation dose after-the-fact. One of the potentially limiting factors in this...Full Text Available
Although skin is usually exposed during human exposures to ionizing radiation, there have been no thorough examinations of the transcriptional response of skin fibroblasts and keratinocytes...Full Text Available
A compensatory response, viz. in vivo recovery from radiation damage to mitochondria, occurs in preclimacteric pear fruits (Pyrus communis L.) treated with ionizing...Full Text Available
This guidebook organizes the profusion of rules and regulations surrounding radiation protection into a single-volume reference. Employee and public protection, accident prevention, and emergency preparedness are included in this comprehensive coverage. Whenever possible, information is presented in convenient checklists, tables, or outlines that enable you to locate information quickly.
The annealing behavior of the radiation damage in epitaxial Pd_2Si and NiSi_2 films on Si, due to the implantation of 100 keV Ar ions, is investigated by using the channeling technique with "4He ions. (U.K.).
Many mechanical parts are subjected to stresses and strains that may eventually lead to their failure. In order to prevent the costly delays associated with equipment down-time, many parts have to be tested for weaknesses and defects when machinery is constructed or dismantled for maintenance. These procedures are known as Non-Destructive Testing (NDT) methods. Five types of non-destructive testing methods routinely used are radiographic testing, ultrasonic testing, magnetic particle inspection, liquid penetrant testing and eddy current testing. Out of these five techniques industrial radiography plays an important role in non-destructive testing to reveal interior defects in materials. In radiography almost two-thirds of the radiation reaching the film is scattered radiation which does not form the image of defects. Scattered radiation generated inside and outside a material has a very large effect on sensitivity of flaw ...
In many radiotherapy clinics, geometric uncertainties in the delivery of 3D conformal radiation therapy and intensity modulated radiation therapy of the prostate are reduced by aligning the...Full Text Available
The mission includes a reflected solar instrument retrieving at-sensor .... incoming solar radiation. This direct aerosol radiative forcing (DARF) ... examining the behavior of geosynchronous rocket bodies and non-stabilized payloads as ...
The chapter presents the nuclear energy development in 20th century and the most important radiation accidents happened from the point of view of technological risk and high impact consequences: Three Mile Island and Chernobyl.