Eddy current testing is one of the most widely used methods in non-destructivetesting for the inspection of conductive materials. Numerical modelling of eddy current testing has emerged as an important approach alongside experimental studies. This paper investigates an application of numerical modelling and experimental study as a means of the quantitativenon-destructive evaluation (QNDE) of defects in conductive samples. There are two methods of measuring eddy current response, more commonly by measuring the change in impedance of the eddy current probe coil, or as used in this work, by measuring the change in magnetic field directly using magnetic field sensors such as superconducting quantum interference devices, giant magneto resistance, or as in this case Hall sensors. Specifically,...
The newly developed techniques by the Hot Laboratory (JMTR HL) have provided for us the key information on behavior of specimens due to mechanical / physical / chemical / synergistic effects of radiation, stress and water for fission and fusion reactor environment. These techniques are focused on several topics as follows; (1) miniaturized specimen test for the development of fusion reactor materials, (2) slow strain rate tensile testing (SSRT) and crack propagation measuring tests for the study of Irradiation Assisted Stress Corrosion Cracking (IASCC) of core internals of LWR, (3) handling technique on specimens including tritium for the research and development of tritium breeders and neutron multiplier as fusion blanket materials, (4) joining method using the Tungsten Inert Gas (TIG) welding technique for re-assembling of capsule and re-fabrication of specimen and (5) nondestructive evaluation using ...
The design and material characteristics of garter spring were summarized and Nondestructive detection techniques of garter spring were also described. In particular, Eddy current testing of loose type garter spring was used in Wolsung unit 1 and was described in detail. The inspection technique of tight type garter spring has not been established and all candidated techniques were investigated in order to choose the possible detection technique. Candidated nondestructive techniques including RFEC, PEC, Magnetic technique using GMR sensor, AE, Guided Wave technique, and high frequency ultrasonic technique, are summarized for evaluating the detectability of tight garter spring.
The use of nondestructive evaluation (NDE) methods is proposed for characterization of transuranic (TRU) waste stored at the Radioactive Waste Management Complex. These NDE methods include real-time x-ray radiography, real-time neutron radiography, x-ray and neutron computed tomography, thermal imaging, container weighing, visual examination, and acoustic measurements. An integrated NDE system is proposed for characterization and certification of TRU waste destined for eventual shipment to the Waste Isolation Pilot Plant in New Mexico. Methods for automating both the classification waste and control of a complete nondestructive evaluation/nondestructive assay system are presented. Feasibility testing of the different NDE methods, including real-time x-ray radiography, and development of automated waste classification techniques are covered as part of a five year effort designed to yield a production ...
Even though the currently intensive research efforts on high- temperature superconducting materials have not yet converged on a well specified practical material, the indications are that such a material may be quite brittle, anisotropic, and may contain many flaws such as microcracks and voids at grain boundaries. Consequently, practical applications of high temperature superconducting materials will require a very careful strength analysis based on fracture mechanics considerations. Because of the high sensitivity of the strength of such materials to the presence of defects, methods of quantitativenon-destructive evaluation may be expected to play an important role in strength determinations. This proposal is concerned with the use of ultrasonic methods to detect and characterize isolated cracks, clusters of microcracks and microcracks distributed throughout the material. Particular attention has been, and will continue to be devoted to ...
The repeated use and limited lifetime of a composite tiring vessel compel a need to survey techniques for monitoring the structural integrity of the vessel in order to determine when it should be retired. Various nondestructive techniques were researched and evaluated based on their applicability to the vessel. The methods were visual inspection, liquid penetrant testing, magnetic particle testing, surface mounted strain gauges, thermal inspection, acoustic emission, ultrasonic testing, radiography, eddy current testing, and embedded fiber optic sensors. It was determined that embedded fiber optic sensor is the most promising technique due to their ability to be embedded within layers of composites and their immunity to electromagnetic interference.
The final product of the radwaste conditioning process must satisfy certain requirments and physico-chemical properties in order to assure its safe long-term behaviour. Of course, the foreseen quality assurance and quality control should be conducted by means of non-destructive techniques. This work presents an over-view of various applicable non-destructive methods of analysis, showing their fields of investigation in testing waste packages, together with some arising practical problems. The most promising methods, such as eddy current testing, ultrasonic testing, #gamma#-scanning, #gamma#-spectroscopy, neutron counting and computerized tomography, are treated more deeply and some applications are presented. Particular attention is devoted to the development of a device based on computerized tomography; its essential components are reported and some design problems are also ...
The report describes the studies carried out to design a non-destructive system for the radiological characterization of packages containing LLW and MLW. This technique is applied for quantitative and qualitative gamma emitters determination in packages with homogeneous and heterogeneous matrices as well as the development of a maximum activity points location system. Development involves also the automatization for its industrial use.
This annex provides a description of the sensor schemes and the non-destructivetesting (NDT) methods that have been investigated in this project. Acoustic emission and fibre optic sensors are described in some detail whereas only the key features of well-established NDT methods are presented. Estimates of the cost of different sensor systems are given and the advantages and disadvantages of the different schemes is discussed. (au)
Many mechanical parts are subjected to stresses and strains that may eventually lead to their failure. In order to prevent the costly delays associated with equipment down-time, many parts have to be tested for weaknesses and defects when machinery is constructed or dismantled for maintenance. These procedures are known as Non-DestructiveTesting (NDT) methods. Five types of non-destructivetesting methods routinely used are radiographic testing, ultrasonic testing, magnetic particle inspection, liquid penetrant testing and eddy current testing. Out of these five techniques industrial radiography plays an important role in non-destructivetesting to reveal interior defects in materials. In radiography almost two-thirds of the radiation reaching the film is ...
A single radial hemolysis test was developed for quantitation of specific antibody to non-hemagglutinating viruses. With the human coronaviruses as models, this test utilizes the binding properties...Full Text Available
Heat transfer tubes of a primary pressurized water cooled (PPWC) in the high temperature engineering test reactor (HTTR) form the reactor pressure boundary of the primary coolant, therefore are important from the viewpoint of safety. To establish inspection techniques for the heat transfer tubes of the PPWC, an automatic inspection system was developed. The system employs a bobbin coil probe, a rotating probe for eddy current testing (ECT) and a rotating probe for ultrasonic testing (UT). Nondestructivetest of a half of the heat transfer tubes of the PPWC was carried out by the automatic inspection system during reactor shutdown period of the HTTR (about 55% in the maximum reactor power in this paper). The nondestructivetest results showed that the maximum signal-to-noise ratio was 1.8 in ECT. Pattern and phase of Lissajous wave, which ...
This review of methods and designs of transducers for nondestructive determination of the magnitude and nature of the anisotropy of magnetic properties (permeability, induction, coercive force, energy loss due to magnetization reversal) in local portions of ferromagnetic sheet and, in some cases, in individual parts of products. The need to measure the anisotropy is considered for two angles: for the case when the anisotropy is due to the crystallographic texture and determines the main operating characteristics of widely used sheet such as electrical steel and automobile body sheet, and for crystallographically isotropic materials, in which the anisotropy of magnetic properties as a result of mechanical stresses is a measure for determining the internal stresses.
Correlation characteristics of quantum noise on the shadow radiation image (RI) of the object under nondestructivetesting are studied. Mathematical model of RI occasional distortions is derived. The model takes into account the parameters of object under testing and of radiation beam by radiation quanta flux density. The results obtained can be used as a component in the process of investigation of various radiation testing systems
We have exploited ``progeny testing'' to map quantitative trait loci (QTL) underlying the genetic variation of milk production in a selected dairy cattle population. A total of 1,518 sires, with progeny...Full Text Available
Today`s nuclear power plants are marked by increasing needs for non-destructive inspection techniques in preventive maintenance programs. Additionally, it is becoming more important to evaluate residual stress which may be a key parameter for crack propagations in welded pipings. The authors have developed an ultrasonic velocity measurement method which obtains ultrasonic velocity changes by residual stress with a high accuracy. The ultrasonic velocity measurement is composed of three procedures. They are as follows. (1) Highly accurate propagation time measurements; (2) Pipe thickness correction; (3) Residual stress evaluation. The ultrasonic velocity measurements have been applied to the residual stress evaluation of carbon steel welded pipings. Destructive testing using stress strain gauges was done after the ultrasonic non-destructive evaluation of the residual stress. The experimental results verified that residual ...
The principle is described of X-ray fluorescence analysis and the manner of detecting the emitted characteristic radiation. The advantages are presented of radionuclide X-ray fluorescence analysis which consist primarily in the possibility of conducting a totally non-destructive analysis, and of accurate and relatively narrow localization of the analyzed area, the simultaneous qualitative and quantitative determinations of a large number of elements in the order of concentrations 10"1 to 10"-"4%, stability of excitation radiation flux, simple design and relatively low capital costs. The so-called matrix effect is pointed to. A number of examples is given of the use of the cited method, including its use in the analysis of art objects. (J.B.).
Dimethyl methylphosphonate (DMMP), a chemical simulant of the nerve gas GB, was decontaminated with a nonthermal atmospheric pressure plasma. The decontamination efficiency was measured qualitatively by means of Fourier transform spectroscopy and quantitatively by means of gas chromatography. With helium gas only, 10g/m2 of DMMP on an aluminum surface was 99.9% decontaminated in 2min, furthermore, with the addition of 5% of oxygen gas, it was 99.99% decontaminated in 10min. Given the low input power (<100W) and temperature (<75degreeC), this plasma is eligible for nondestructive decontamination of almost all material surfaces.
Eddy current testing (ECT) method is widely used as the non-destructive evaluation (NDE) of the various kinds of material degradation occurring in nuclear power plants (NPPs) components including steam generator (SG) tubes. Detection of any defects or flaws in the steam generator tubes in the early stage is very important in maintenance of NPP for its primary role as the pressure boundary with thin wall thickness. Although the ECT technique provides lots of information for a SG management, it has a generic problem in its reliability due to a low ability in detect of small defects and some difficulty in a signal analysis. For the improvement of these shortcomings in conventional ECT, profile-MRPC (motorized rotating pancake coil) ECT technology was developed in KAERI. The key of this new technology is the development of new eddy current probes, designated as a diagnostic probe (D-probe). The D-probe is furnished with a simultaneous dual function ...
Eddy current testing (ECT) method is widely used as the non-destructive evaluation (NDE) of the various kinds of material degradation occurring in nuclear power plants (NPPs) components including steam generator (SG) tubes. Detection of any defects or flaws in the steam generator tubes in the early stage is very important in maintenance of NPP for its primary role as the pressure boundary with thin wall thickness. Although the ECT technique provides lots of information for a SG management, it has a generic problem in its reliability due to a low ability in detect of small defects and some difficulty in a signal analysis. For the improvement of these shortcomings in conventional ECT, profile-MRPC (motorized rotating pancake coil) ECT technology was developed in KAERI. The key of this new technology is the development of new eddy current probes, designated as a diagnostic probe (D-probe). The D-probe is furnished with a simultaneous dual function ...
The meeting featured seven sessions with 18 papers abstracted/indexed therein as follows: keynote address: tailings dams safety - implications for the dam safety community; 1 - design and performance: performance monitoring of dams: are we doing what we should be doing?; tailings dams from the perspective of conventional dam engineering; and design overview of Syncrude's Mildred Lake east toe berm; 2 - design and modelling: use of a 2D model for a dam break study on the ALCAN hydroelectric complex in Quebec; and spillway design implications resulting from changes in rainfall extremes; 3 - risk and dam safety I: closing the gaps in the dam safety guidelines; the reality of life safety consequence classification; and surveillance practices for the next millenium; 4 - risk and dam safety II: quantitative risk-assessment using the capacity-demand analysis; and new guidelines for dam safety classification; 5 - millenium issues: expectations of immortality, dam ...
The results show that the SQUID device eddy current testing system is a suitable tool for NDE. Due to the high low-frequency sensitivity of the SQUID sensor, the SQUID device eddy current testing system permits lower examination frequencies than the conventional eddy current probe system. The SQUID system enhances fault detection in even deeper materials layers. (orig./MM).
Neutron radiography (NR) is a useful non-destructive method for determination of hydrogen content in various building and technical materials. Monitoring of transport processes of moisture and hydrogenous liquids in porous building materials is enabled by fast, quasi-real-time NR methods based on novel imaging plate neutron detectors (IP-NDs). Hydrogen content in the samples is determined by quantitative analysis of measured profiles of neutron attenuation in the samples. Detailed description of quantitative NR method is presented by the authors in another accompanying contribution at this conference. Deterioration of building materials is originated by different processes that all require presence of water therefore it is essential to limit or prevent the transport of water through the porous material. In this presentation, results of a study of clay brick impregnation by silicone based hydrophobic agents will be ...
Methods of automated control of 18-10-type steel inclination to IGC are developed and a corresponding automated testing complex (ATS) is created. 08Kh18N10T steel samples had two variants of thermal treatment: 1) 1200 deg (5 h), 600 deg (50 h); 2) 1200 deg (5 h). Methods of non-destructive automated control of 18-10-type steel inclination to IGC are developed on the basis of potentiodynamic reactivation (PR) principle. Automated testing complex is developed, which has undergone experimental running and demonstrated a high confidence of results, reliability and easy operation.
Preliminary results of studies into penetrant testing at high surface temperature (up to 200 deg.C), are presented. Tests were performed to assess the effectiveness of red dye penetrants using Al and NiCr samples containing artificial as well as natural discontinuities. The test results will be used in due course to formulate a specification for non-destructivetesting procedure qualification at non-standard (i.e. outside 16-52 deg.C) temperatures.
The principle is described of a method using low-activity emitters as the primary radiation source for analysis. The selection of the radiation source and the detection methods including the assessment of the applicability of various radiation detectors are discussed. The benefits and the constraints of the method are considered. Practical examples are presented showing the application possibilities of the method for testing the thickness of bearing layers, piston ring coats, lead layers, etc. The possibility is shown of applying the rapid test for the composition of tungsten and chromium alloyed metal materials in testing complex systems. (J.K.).
Nondestructive inspection of carbon fibre-reinforced plastics (CRFP) using eddy current methods is based not only on the conductivity of the fibres. High frequencies (up to 10 MHz) give access to capacitive effects reflecting properties of the matrix. The paper presents a method using rotating eddy current probes to measure the anisotropic electrical properties. Potential applications of this method are the structural identification of laminates and the estimating of its degradation. (orig.)
In this study the development of a methodology to detect illicit drugs and plastic explosives is described with the objective of being applied in the realm of public security. For this end, non-destructive assay with neutrons was used and the technique applied was the real time neutron radiography together with computerized tomography. The system is endowed with automatic responses based upon the application of an artificial intelligence technique. In previous tests using real samples, the system proved capable of identifying 97% of the inspected materials.
BackgroundSeveral fractal and non-fractal parameters have been considered for the quantitative assessment of the vascular architecture, using a variety of test specimens and of computational...Full Text Available
In principle four different methods (ultrasound, microwaves, {gamma}-radiation and x-rays) are available for the non-destructivetesting of refractories. Three of these methods, i.e. ultrasound, microwaves and {gamma}-radiation, are in use by different producers of AZS materials to carry out the quality control of their products. This paper will compare the three methods on the basis of the physical properties, present the existing devices, and show the advantages as well as the limits of the different methods. {gamma}-radiography, the oldest method in use, has one main disadvantage, which is the requirement of protection against radioactive radiation. Furthermore, while cracks and cavities can be detected with this method, structural changes can not be monitored. Therefore, the ultrasonic method was developed that allows to detect variations of porosity and grain size as well as cracks and voids when the ultrasonic parameters are tuned as well ...
The Fast Flux Test Facility (FFTF) reactor, which started operating in 1982, is a 400 MWt sodium-cooled fast neutron reactor located in Hanford, Washington State, and operated by Westinghouse Hanford Co. under contract with U.S. Department of Energy. The reactor has a wide variety of functions for irradiation tests and special tests, and its major purpose is the irradiation of fuel and material for liquid metal reactor, nuclear reactor and space reactor projects. The review first describes major technical specifications and current conditions of the FFTF reactor. Then the plan for irradiation testing is outlined focusing on general features, fuel pin/assembly irradiation tests, and absorber irradiation tests. Assemblies for special tests include the material open test assembly (MOTA), fuel open test ...
The Fast Flux Test Facility (FFTF) reactor, which started operating in 1982, is a 400 MWt sodium-cooled fast neutron reactor located in Hanford, Washington State, and operated by Westinghouse Hanford Co. under contract with U.S. Department of Energy. The reactor has a wide variety of functions for irradiation tests and special tests, and its major purpose is the irradiation of fuel and material for liquid metal reactor, nuclear reactor and space reactor projects. The review first describes major technical specifications and current conditions of the FFTF reactor. Then the plan for irradiation testing is outlined focusing on general features, fuel pin/assembly irradiation tests, and absorber irradiation tests. Assemblies for special tests include the material open test assembly (MOTA), fuel open test ...
This paper addresses known limitations and constraints in eddy current nondestructivetesting. Incomplete appreciation for eddy current limitations is believed to have contributed to both under-utilization and misapplication of the technique. Neither situation need arise if known limitations are recognized. Some, such as the skin depth effect, are inherent to electromagnetic test methods and define the role of eddy current testing. Others can be overcome with available technology such as surface probes to find circumferential cracks in tubes and magnetic saturation of ferromagnetic alloys to eliminate permeability effects. The variables responsible for limitations in eddy current testing are discussed and where alternative approaches exist, these are presented. Areas with potential for further research and development are also identified.
Non-destructivetesting (NDT) is a dynamic technology and progresses with time. Since the issuance of IAEA-TECDOC-628 in 1991, the technology has experienced numerous changes. Advancements in knowledge about the behaviour of materials have led to changes in the applicable NDT codes, standards and specifications. In addition, over the last ten years, as a result of extensive research and development activities worldwide, new NDT techniques and equipment have been developed which are accepted by engineering community. To accommodate the latest developments, modifications are required to training materials. The present publication is an updated version of IAEA-TECDOC-628. The modifications were made during an Advisory Group Meeting, held in Vienna from 25-29 June 2001. The content of the first edition of IAEA-TECDOC-628 has been revised based on the experience of the experts, as well as comments of the end-user industries. The time allotment for ...
The paper reports the progress made by the ITER Home Teams in the development of robust carbon and tungsten armoured plasma facing components for the ITER divertor. The activities on the development and study of armour materials, joining technologies, non-destructive evaluation techniques, high heat flux testing of manufactured components and neutron irradiation resistance studies are presented. The results of these activities confirm the feasibility of the main divertor components. Examples of the fruitful collaboration between Parties and future R and D needs are also described. (author)
Real-time neutron radiography (RTNR) is rapidly becoming a valuable tool for nondestructivetesting and basic research with a wide variety of applications. The Phoenix Memorial Laboratory (PML) at the University of Michigan has developed an RTNR facility and has been using this facility to study several phenomena of interest to researchers in many areas. These phenomena include imaging of the internal fluid flow in gas turbine engine nozzles and coking and debris deposition in several gas turbine nozzles. This paper presents a summary of the technique and facilities involved in these applications.
Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A "2"3"8Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed. (author).
The paper provides a brief description of the fuel characterization for Fast Breeder Test Reactor (FBTR) and Prototype Fast Breeder Reactor (PFBR). The development and characterization of mechanical properties of Alloy D9 clad and wrapper tubes are discussed. The problems associated with fusion welding of Alloy D9 are outlined. Non-destructive characterization of cladding tubes by optimum encircling eddy current probes, on-line and off-line neural network methods is presented. Both the on-line and off-line neural network methods could readily detect and size defects specified by the designers
The purpose of this study was to use high-resolution magnetic resonance (MR) imaging combined with image analysis to investigate the three-dimensional (3D) trabecular structure, anisotropy, and connectivity of human vertebral, femoral, and calcaneal specimens. The goal was to determine whether: (a) MR-derived measures depict known skeletal-site-specific differences in architecture and orientation of trabeculae; (b) 3D architectural parameters combined with bone mineral density (BMD) improve the prediction of the elastic modulus using a fabric tensor formulation; (c) MR-derived 3D architectural parameters combined with BMD improve the prediction of strength using a multiple regression model, and whether these results corresponded to the results obtained using higher resolution depictions of trabecular architecture. A total of 94 specimens (12 x 12 x 12 mm cubes) consisting of trabecular bone only were obtained, of which there were 7 from the calcaneus, 15 from distal femur, 47 from the ...
The main LHC superconducting magnets (dipoles and quadrupoles) use Rutherford type cables, stabilized electrically and thermally with copper profiles. The portions of cables are connected to each other by a soft soldering technique (Sn96Ag4) with an overlapping length corresponding to one pitch of the superconducting strands. The splice constitutes a "composite" structure with the interchanging layers of Sn96Ag4 and NbTi superconductor, located inside a Cu cage. In order to ensure a high level of reliability (failure probability not exceeding 10-8) for some 10000 connections in the LHC, a non-destructive technique to check the quantity of solder in the joint is foreseen. The technique is based on a gamma ray source (241Am) and the detection is position-sensitive in the transmission mode. Scintillating detectors of gamma rays are used and their accumulated length corresponds to the length of the radioactive source (120 mm). The method can be used in-situ, the ...
Bobbin-coil-type eddy current probes, which are conventionally used for nondestructive inspection of steam generator tubes in pressurized-water-type nuclear power plants, have poor detectability for circumferential flaws. Hence a new type of eddy current probe was proposed to detect effectively the magnetic flux component disturbed by a flaw and thus to eliminate the flaw direction dependency on the flaw detectability. In the course of development of the proposed method, structures of the probe were investigated based on the measurement of magnetic fields induced by exciting flat coils with several shapes. The new type of probe proposed here consists of differential pick-up coils detecting magnetic flux and exciting coils having a parallelogrammic shape, and its structure was fabricated experimentally in order to detect flaws independently of their directions. Nondestructive flaw detection tests was then conducted by using ...
A quantitative description is presented of the non-linear current-voltage response in superconducting niobium cavities for accelerator application. It is based on a fit for a large sample of data from cavity tests of different kind. Trial functions for the surface resistance describing this non-linear relation are established by a least square data fit. Those trial functions yielding the best fit are quantitatively explained by basic physics.
The overall objective of this project is to produce antibodies to unique modified DNA bases and develop immunochemical assays to quantitate these lesions in damaged DNA. During this past year we have developed an antibody and chemical test to quantitate a basic sites in DNA and produced antibodies to the 8-oxopurines. This report discusses the detection of a basic sites in DNA and the preparation of antibodies to 8-hydroxyadenine and 8-hydroxyguanine.
Abstract Background: Aution Max AX-4030, a test strip analyzer recently introduced to the market, represents an upgrade of the Aution Max AX-4280 widely employed for urinalysis. This new instrument model can allocate two different test strips at the same time. In the present study the two instruments have been compared together with the usage of Uriflet 9UB and the recently produced Aution Sticks 10PA urine strips, the latter presenting an additional test area for the measurement of urinary creatinine. Methods: Imprecision and correlation between instruments and strips have been evaluated for chemical-physical parameters. Accuracy was evaluated for protein, glucose and creatinine by comparing the semi-quantitative results to those obtained by quantitative methods. The well-known interference effect of high ascorbic acid levels on urine glucose test strip ...
The Pacific Northwest National Laboratory (PNNL) has nearly a 40 year history of research and development in the field of nondestructive evaluation (NDE). One area of NDE expertise at PNNL is electromagnetic testing which includes a field of eddy current testing (ET). One benefit is that ET can typically be performed at high speeds, and as a result has found many applications in process monitoring and poduction lines. ET has been used in the nuclear, aerospace, and automotive industries for many years. Et technology lends itself well to the detection of near-surface or surface breaking defects such as surface scratches. This paper provides an overview of theory regarding the usage of ET, selected application studies performed by PNNL, a safety analysis, and a wrtie up pertaining to the operations of ET to detect surface scratches.
Corrosion of steam generator heat transfer tubes (SGHTT) is one of the important problems which affect safety operation of nuclear power plants (NPP), and the hazard of pitting corrosion of heat transfer tubes is the most serious. With an acoustic emission device, the signals during a corrosion test on SGHTT were collected and analyzed, and the corrosion points in the tubes were located accurately. The results show that pitting corrosion of heat transfer tubes has passed through three periods in its development: expansion phase, stationary phase and rapid developing phase. The corrosion damage of HTT can be found earlier with acoustic emission than any other non-destructivetesting methods. Acoustic emission can be used for on-line and real-time monitoring of the safety and operation of the steam generator and has therefore a great significance. (orig.)
The Materials and Components Technology Division (MCT) provides a research and development capability for the design, fabrication, and testing of high-reliability materials, components, and instrumentation. Current divisional programs related to nuclear energy support the development of the Integral Fast Reactor (IFR): life extension and accident analyses for light water reactors (LWRs); fuels development for research and test reactors; fusion reactor first-wall and blanket technology; and safe shipment of hazardous materials. MCT Conservation and Renewables programs include major efforts in high-temperature superconductivity, tribology, nondestructive evaluation (NDE), and thermal sciences. Fossil Energy Programs in MCT include materials development, NDE technology, and Instrumentation design. The division also has a complementary instrumentation effort in support of Arms Control Technology. Individual abstracts have been ...
This paper introduces the application of independent component analysis mixture modelling (ICAMM) in non-destructivetesting (NDT). The application consists of discriminating patterns for material quality control from homogeneous and defective materials inspected by impact-echo testing. This problem is modelled as a mixture of independent component analysis (ICA) models, representing a class of defective or homogeneous material by an ICA model whose parameters are learned from the impact-echo signal spectrum. These parameters define a kind of particular signature for the different defects. The proposed procedure is intended to exploit to the maximum the information obtained with the cost efficiency of only a single impact. To illustrate this capability, four levels of classification detail...
The IGC Highlights briefly outlines some of the the significant progresses made by Indira Gandhi Centre for Atomic Research, Kalpakkam during the period 1996-1997. The Fast Breeder Test Reactor (FBTR) was operated at the maximum power level possible with the available partial core. The first generation of electricity from FBTR and its synchronization with the grid in 1997 marked a significant step in the nuclear programme of the Centre. Another important event was the commissioning of the "2"3"3U - fuelled Kamini reactor.The mission-oriented programmes in fast reactor technology was supported by a host of research and development programmes, in closely related areas namely materials technology, welding metallurgy, sodium technology, manufacturing technology, non-destructivetesting, quality engineering, in-service inspection, electronics and instrumentation and safety research. The Highlights also contains the organisation ...
The formaldehyde surface emission monitor (FSEM) has been developed for passive non-destructive measurement of formaldehyde (CH/sub 2/O) emission rates from CH/sub 2/O resin-containing materials. It is envisaged as a potential quality control and in-situ monitoring technique. For quality control applications to pressed-wood products, strong correlations between the results of the FSEM and environmentally controlled (small scale) chamber tests were observed. The FSEM is used to measure the cumulative CH/sub 2/O emission from a finite area of pressed-wood product during a fixed test period. The final result is reported as an average CH/sub 2/O emission rate (mg CH/sub 2/O/m/sup 2/h).
After a brief review of the degradations occurring on tubes of Inconel 600 in steam generators of PWR power stations emphasis is put on the conditioning of the secondary water and more particularly on the condensate treatment in the units of Doel which work on heavily polluted brackish water. The important role of non-destructivetesting and eddy-current testing is also pointed out, method developed by Laborelec. The operational experience shows that Belgian stations are nearly not concerned by the degradations mostly found in power stations in other countries which shows the efficiency of the conditioning of the secondary water. On the other hand, other problems have occurred, resulting from: damage caused by foreign objects; fouling of tube before commissioning, cracking of bends and at the limit of the dudgeoning and leaking plugs. (AF).
A quantitative trait locus (QTL) analysis designed for a multi-parent population was carried out and tested in oil palm (Elaeis guineensis Jacq.), which is a diploid cross-fertilising...Full Text Available
The purpose of the work was to quantitatively characterize temperature effects on the bacterial leaching of sulfide ore material containing several sulfide minerals. The leaching was tested at eight...Full Text Available
BackgroundQuantitative sensory testing (QST) is applied to evaluate somatosensory nerve fiber function in the spinal system. This study uses QST in patients with sensory dysfunctions...Full Text Available
The aim of this work is to investigate the acoustic wave generation by pulsed and periodically modulated ion beams in different solid materials depending on the beam parameters and to demonstrate the possibility to apply an intensity modulated focused ion beam (FIB) for acoustic emission and for nondestructive investigation of the internal structure of materials on a microscopic scale. The combination of a FIB and an ultrasound microscope in one device can provide the opportunity of nondestructive investigation, production and modification of micro- and nanostructures simultaneously. This work consists of the two main experimental parts. In the first part the process of elastic wave generation during the irradiation of metallic samples by a pulsed beam of energetic ions was investigated in an energy range from 1.5 to 10 MeV and pulse durations of 0.5-5 #mu#s, applying ions with different masses, e.g. oxygen, silicon and gold, in charge states ...
A novel method for non-destructive intramuscular fat (IMF) estimation via spectral ultrasound backscatter analysis of signals obtained from pig carcasses early post mortem is described. A commercial hand-held ultrasound device (center frequency: 2.7MHz) was modified to focus the sound beam to the longissimus muscle at the 2nd/3rd last rib. Time-resolved ultrasound backscatter signals of loin muscle were recorded 45minp.m. on 82 pig carcass sides. Backfat width (d"B"F=18.9+/-3.8mm) and muscle attenuation (@a"m"u"s"c"l"e=.77+/-.15dBMHz^-^1cm^-^1) were assessed from the measured pulse echo data. Other propagation properties of skin, backfat and muscle tissue obtained in a previous investigation were incorporated into the signal pre-processing to minimize parameter estimation artifacts. Spectr...
Geological clay formations are investigated for use as final underground deposit for heat producing nuclear waste. Special kinds of clay (e.g. bentonite) can also be used for the construction of geotechnical barriers. For the long time safety prognosis of the nuclear waste repositories the development of geochemical transport models is indispensable. The transport of aqueous solutions in clay is a complex process. The three-layer-minerals bentonite and illite swell by the adsorption of water, if the volume is restricted a high swelling pressure develops. The excellent barrier effect of natural clay formations and geotechnical clay barriers is based on the high swelling pressure and the high adsorption capacity for radionuclides and other pollutants. The two-layer-mineral kaolinite has no swelling capacity. In contrast to sandy layers a special geochemical transport potential exists in clay besides the well known matrix potential which influences essentially the transport process. ...
A clinical laboratory evaluation was conducted on the Clinitek Auto 2000, the Super Aution Analyzer and the Urotron RL9 for the determination of glucose, protein, pH, blood, ketone-bodies and bilirubin.Precision of the systems was tested using three commercial control urine materials, and reported as the percentage of times the instrument repeats a certain value. Good repeatability was obtained with all the instruments.Accuracy of the systems was evaluated by comparison with quantitative procedures, and to check agreement between methods yielding semi-quantitative and quantitative results, ranges of acceptability were defined, based on the criteria reported in a previous paper [2]. It was then found that 87.5 to 98.9% of results from the Urotron RL9 and the Clinitek Auto 2000 were acceptable. With the Super Aution Analyzer the level of agreement was apparently lower because of the higher number of ...
Boat sampling technique (BST) is a surface sampling technique, which has been developed for obtaining, in-situ, metal samples from the surface of an operating component without affecting its operating service life. The BST is non-destructive in nature and the sample is obtained without plastic deformation or without thermal degradation of the parent material. The shape and size of the sample depends upon the shape of the cutter and the surface geometry of the parent material. Miniature test specimens are generated from the sample and the specimens are subjected to various tests, viz. Metallurgical Evaluation, Metallographic Evaluation, Micro-hardness Evaluation, sensitisation test, small punch test etc. to confirm the integrity and assessment of safe operating life of the component. This paper highlights design objective of boat sampling technique, description of sampling module, ...
The United States Air Force School of Aerospace Medicine (USAFSAM) tests the quantitative fit of masks which are worn by military personnel during nuclear, biological, and chemical warfare. Subjects are placed in a Dynatech-Frontier Fit Testing Chamber, salt air is fed into the chamber, and samples of air are drawn from the mask and the chamber. The ratio of salt air outside the mask to salt air inside the mask is called the quantitative fit factor. A motion-time study was conducted to evaluate the efficiency of the layout and work method presently used in the laboratory. A link analysis was done to determine equipment priorities, and the link data and design guidelines were used to develop three proposed laboratory designs. The proposals were evaluated by projecting the time and motion efficiency, and the energy expended working in each design. Also evaluated were the lengths of the equipment links for ...
Radionuclide X-ray fluorescence analysis (RXRFA), as a non-destructive method, relatively simple and allowing measurements to be carried out in situ, is an excellent tool in research on various objects of art. A range of artefacts have been investigated by our laboratory, in part for the purposes of history of art and in part as a basis for restoration works - medieval frescoes in some Czech castles and churches, metal sculptures and objects of applied art, paints and inks of old manuscripts, paintings. Some of these are among the most valuable monuments in the Czech cultural heritage. The contribution of the results of the tests to the investigation of their 'life story' and, in some cases, to their conservation, is not negligible. Later additions and repairs can be recognised, and materials and technologies that are close to their historic counterparts can be used in restoration work.
Radionuclide X-ray fluorescence analysis (RXRFA), as a non-destructive method, relatively simple and allowing measurements to be carried out in situ, is an excellent tool in research on various objects of art. A range of artefacts have been investigated by our laboratory, in part for the purposes of history of art and in part as a basis for restoration works - medieval frescoes in some Czech castles and churches, metal sculptures and objects of applied art, paints and inks of old manuscripts, paintings. Some of these are among the most valuable monuments in the Czech cultural heritage. The contribution of the results of the tests to the investigation of their 'life story' and, in some cases, to their conservation, is not negligible. Later additions and repairs can be recognised, and materials and technologies that are close to their historic counterparts can be used in restoration work.
Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A /sup 238/Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed.
The objective of the inspection qualification is to ensure that applied non-destructive methods (NDT) have the required performance. The approach of the qualification process is systematic and carefully documented and therefore some new requirements can be seen concerning the composition of the documentation. There are also new document types, that only application of the inspection qualification requires. The most important of these is the technical justification, that includes the documented evidences concerning the performance of the inspection system. This publication includes two reports: 'Compilation of the inspection procedure' and 'Essential/influential parameters in NDT qualification'. The former of these discusses the issues to be considered in an inspection procedure especially from the point of view of the mechanised ultrasonic testing. The later report explains the parameters formulated to ...
The renovation programme of the Phenix nuclear power plant (fast neutrons reactor situated at Marcoule) has for objective to ensure the reactor operation lengthening. In this frame, expertise and monitoring operation in situ of materials have been started. The presence of sodium and a temperature at the cold breakdown of the primary circuit between 150 and 180 degrees (Celsius) imply, for fast reactors, very special conditions. In this context, Framatome has realised three intervening in the area of nondestructivetesting: the inspection of the cone-shaped support ring, the monitoring of the upper part of the primary vessel and the monitoring of the intermediary exchanger equipment. (N.C.)
Corrosion failures in circuits of foreign NPPs are considered. According to American statistics there are more corrosion failures in two-circuit NPPs than in NPPs with one circuit. Steam generators mostly suffer from ''corrosion denting''. Lately pitting corrosion becomes a potentially serious problem. Steam generator vertical tubes are mainly subjected to this corrosion type. Attention is drawn to intercrystalline corrosion. The causes of corrosion are described. The problem of optimization of structural materials is discussed to reduce corrosion failures as well as other methods of decreasing corrosion failures. Organization of nondestructivetesting, increased requirements to water and steam purity are of great importance.
Turbine sets are inspected at their overhaul intervals throughout their operating lives. Using three examples, the present article describes the procedure in the inspection and assessment of steam turbines during overhauls and also deals with rehabilitation measures. In addition to the usual non-destructivetests and the recording of findings, computational life assessments are also considered. (orig.) [Deutsch] Turbosaetze werden waehrend ihrer Betriebszeit anlaesslich von Revisionen ueberprueft. Anhand von drei Beispielen wird in diesem Beitrag die Vorgehensweise bei der Pruefung und Bewertung von Dampfturbinen bei Revisionen und fuer Rehabilitationsmassnahmen dargestellt. Neben ueblichen zerstoerungsfreien Pruefungen und Befundaufnahmen erfolgten in Verbindung damit auch rechnerische Lebensdauerbewertungen. (orig.)
Laboratory testing at Combustion Engineering has indicated promise in controlling simulated steam generator tube denting through chemical neutralization. Testing was limited to on-line treatment, and two neutralizers have been evaluated: calcium hydroxide and boric acid. On-line treatment with calcium hydroxide successfully halted active denting whenever the bulk calcium concentration (in ppm) equaled or exceeded the bulk chloride concentration (in ppm). Calcium hydroxide also was effective as an alternative to ammonia as a pH controlling agent in two tests conducted without ingress of chloride. On-line treatment with boric acid consisted of a four-day soak at simulated low (approximately 30 percent) power with 50 ppm B followed by one month full-power operation with 10 ppm B. This treatment also halted denting. Nondestructive and destructive examination of test boilers gave no ...
The first fully-documented study into the quantitative impact of errors in operational spreadsheets identified an interesting anomaly. One of the five participating organisations involved in the study contributed a set of five spreadsheets of such quality that they set the organisation apart in a statistical sense. This virtuoso performance gave rise to a simple sampling test - The Clean Sheet Test - which can be used to objectively evaluate if an organisation is in control of the spreadsheets it is using in important processes such as financial reporting.
To ensure safe and reliable power production nuclear power plants must be operated at high level. Non destructive in-service inspections are inseparable part of the effort. Non destructive in-service inspections are essential on the ground of degradation mechanisms existence in nuclear power components. Degradation processes are constituent of operation of each industrial installation including nuclear power plants. Mission of non-destructivetesting is degradation detection, closer characterization of its parameters (dimensions) and to supply as much information as possible to nuclear power plant operator. Eddy current testing method can be assigned to surface - volumetric methods. Method enables inspection of electrically conductive materials. It is particularly suitable for inspection of non-ferromagnetic materials like austenitic stainless steel and brass. The method is used for detection of stress corrosion cracking, ...
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm{sup -3} or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the end application itself ...
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm"-"3 or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the end application itself set ...
A multi-centre evaluation of the test strip analyser, Rapimat, was performed by four laboratories following the ECCLS 2nd draft guidelines for the evaluation of analysers in clinical chemistry. Using the Rapignost urine test strip with the test fields for bilirubin, urobilinogen, acetoacetate, ascorbic acid, glucose, protein, nitrite, pH and haemoglobin, the Rapimat was found to be analytically reliable in comparison with other, in most cases quantitative procedures. During the observation period of about 6 months no breakdown occurred in any laboratory. Interferences and sensitivity as discussed for the bilirubin and urobilinogen test field are more related to the test strip than to the instrument. Several improvements for further developments are suggested. This multi-centre study has shown that the ECCLS protocol is applicable to analytical procedures leading ...
In this paper we present the results of time series analysis for a coal mining region based on partial unmixing. We test the method also known as mixture tuned matched filtering on an eight image Landsat 5 TM and Landsat 7 ETM+ time series covering the period from 1987 to 2003. Common change detection methods often include the comparison of two interactively generated classification results, such as derived from Maximum Likelihood classification. These approaches often yield highly accurate results. However, disadvantages include a strong analyst bias and hardly repeatable results. For a quantitative monitoring of a single surface class' development over time they are often not recommendable. Our goal was to test an unbiased quantitative way to assess the development of coal surfaces, such...
In this paper, the state-of-the-art ultrasonic and magnetic measuring techniques developed at Kawasaki Steel and used in the production process of steel sheets are described. Representative examples shown here are as follows: (1) Magnetic flux leakage testing system for the detection of nonmetallic inclusions, (2) Nondestructive orientation measurement for secondary re-crystallized grains in grain-oriented electrical steel by ultrasonic interferometry, (3) Immersion testing method for the detection of nonmetallic inclusions, (4) Surface wave probe for the detection of surface flaws in rolls used in rolling mills. Developments of these techniques and their applications to actual steel sheets production processes have contributed to advance in technologies for quality assurance and control. With the help of these techniques, steel sheet products with advanced and uniform properties are being continuously produced to meet ...
Analyses of the roles of cement-based barriers in radioactive waste isolation show that models used to estimate their characteristics during the lifetime of the repository must consider the alteration of material properties with time due to degradation processes. Reinforced concrete barriers at repositories shall be designed in such manner that they fulfil besides isolative capabilities also the required functions of mechanical resistance and stability. Key elements of safety evaluation are mainly the correct selection of materials for mineral composites with cement binder (cements, aggregates, mineral additives and chemical admixtures) and their design, execution of construction works and production of precast concrete containers (continuous casting of concrete - no cold joints, limited number of construction joints, proper placing and consolidation, finishing and curing), strict control of used materials and inspection of works, as well as investigation after the construction (visual ...
Helically coiled tubes of steam generators (SG) in FBR are boundaries between sodium and water/steam. Therefore, to assure the integrity of tubes, it is necessary to inspect the tubes nondestructively for in service or after a sodium-water reaction accident. In order to make it possible to conduct in-service inspection of SG tubes, we have studied on eddy current probes and probe inserting methods. As for the probe inserting method, IHI designed a fluid driving type which consists of a model probe and signal cable with float balls and driven by air pressure force. Presented in this paper is the authors' report, which describes the fluid driving type as an effective method to insert an eddy current probe into helically coiled tubes. The outline of the test results is as follows: 1. It was possible to insert the probe into 65 meter length helically coiled tubes. 2. We could detected, as anticipated, a defect (outer circumferential wall thinning ...
During the phases of separation, treatment, conditioning and storage of radioactive waste, destructive and nondestructive methods for their characterization are needed. In order to satisfy this necessity, in the frame of the National Program of Research and Development, the 'Laboratory for characterization of spent nuclear fuel and high/medium level radioactive waste- LABORAD' was created. The purpose of the project was to accredit the analysis methods available in the laboratory, and also to develop new methods for the characterization of the radioactive waste. A special attention was paid to the high-level radioactive waste and spent nuclear fuel characterization that require special facilities for handling. These facilities (e.g. hot cells, remote handlers, transport container) are already available in our institute. Experimental results and performances obtained during validation of the methods are presented in this paper. The laboratory (LABORAD) is notified ...
Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only a small fraction of the neutrons incident on the object are scattered to the neutron camera, a new neutron beamport facility, with a larger neutron flux (7.3 x 10[sup 7] n/cm[sup 2]/s) than the previous ...
A considerable fraction of radioactivity entering the environment from different nuclear events is associated with particles. The impact of these events can only be fully assessed where there is some knowledge about the mobility of particle bound radionuclides entering the environment. The behavior of particulate radionuclides is dependent on several factors, including the physical, chemical and redox state of the environment, the characteristics of the particles (e.g., the chemical composition, crystallinity and particle size) and on the oxidative state of radionuclides contained in the particles. Six plutonium-containing particles stemming from Runit Island soil (Marshall Islands) were characterized using non-destructive analytical and microanalytical methods. By determining the activity of {sup 239,240}Pu and {sup 241}Am isotopes from their gamma peaks structural information related to Pu matrix was obtained, and the source term was revealed. Composition and ...
The alloy type 'alloy 800' with its different variants is used for numerous components in high-temperature reactor (HTR) plants, e.g. for hot-gas conductors, the high-pressure part of steam generators, superheaters, steam collecting vessels and live steam conductors. This study deals with the evaluation of creep rupture tests on 28 welded joints of alloy 800 with an accumulated test duration of 410 years, with the objective to obtain quantitative information on a possible loss of strength in comparison with the unwelded material. The longest test period of an individual test amounted to 98,000 h and the analyzed test temperature range lay between 550"0 and 1000"0C. (orig./MM).
Methods currently being used or developed for the elemental analysis of materials are chemical analysis, non-destructive inspection and calorimetry. The chemical analysis, which removes high-level radioactive elements through chemical treatments and then performs the quantitative analysis using the ICP-MS(Inductively Coupled Plasma - Mass Spectrometer) or the ID-MS(Isotope Dilution Mass Spectrometer), is recognized the most accurate. However, it requires a long, complex pre-treatment process in which a mass spectrometer could be contaminated. To solve this problem, a new method, which can be performed with high-level radioactivity and at high temperature, was desired. Such a method should also have the same accuracy as the chemical analysis, with a less possibility for instruments to be contaminated. In addition, as interests in the environment and the life quality are increased, a detailed analysis on the environmental impacts is also ...
Initial major applications of neutron radiography (NR) to nuclear engineering were nondestructive inspections of nuclear fuel, control rods, reactor materials and some other components. Increase in the available neutron flux over 10{sup 8} n/cm{sup 2}s at the JRR-3M thermal neutron radiography facility (TNRF) in 1991 has expanded the application field to the dynamic but clear imaging of moving objects and fluid phenomena. The JRR-3M TNRF is facilitated with three major imaging systems, being characterized by spatial and/or temporal resolutions: 1. Static neutron radiography (SNR), 2. real-time neutron radiography (RNR) with an imaging rate of 30 frames/s and 3. High-frame-rate neutron radiography (HFRNR). SNR has been used for three-dimensional visualization of air-water two-phase flows in a simulated rod bundle. Three-dimensional computed tomography clearly illustrated average void fraction distributions around tie spacers. RNR has been used for visualization and ...
Gamma scanning measurements are used to determine the radioactive nuclides from an irradiated fuel rod in a hot cell which is a routine task in the Irradiated Materials Examination Facility (IMEF) of the Korea Atomic Energy Research Institute (KAERI), Total gamma spectra of radioactive nuclides and the atomic ratio of {sup 134}Cs to {sup 137}Cs in a few segments of a single fuel rod are measured by the present gamma scanning system. For the purpose of determining the radioactive nuclide's distribution in detail within a fuel rod quantitatively, we attempt to upgrade the present gamma scanning system in this paper, therefore, an investigation of the feasibility of the tomographic gamma scanning (TGS) technique, which is one of the promising nondestructive assay (NDA) methods is proposed. The TGS technique is an efficient method and it has an accurate precision for the characterization of several fuel parameters. In this paper, a ...
Effects of the rapid early-in-life expansion of metal fuel were measured in an irradiation experiment in the Fast Flux Test Facility (FFTF). This important performance/design information was obtainable through the unique combination of a dimensionally stable FFTF oxide core and the calibrated proximity instrumentation associated with the test. These results delineate the time dependence of metal-fuel swelling and provide quantitative estimates of the magnitude of axial fuel swelling in full-length metal-fuel assemblies. Final posttest examination results will define actual fuel column growth levels.
As a basic research to consider aging deterioration of the operating nuclear power plant to seismic fragility analysis, aging deteriorations occurring safety related equipment of both Kori unit 1 and Wolsung unit 1, are investigated in this study. First of all, 378 and 152 safety related equipment are selected at Kori unit 1 and Wolsung unit 1 respectively. Seismic review team including seismic capability engineer, is organized and seismic walkdown is carried out using the nondestructivetests. As a results of seismic walkdown, crack is a typical aging deterioration which can reduce the seismic safety of safety related equipment and the other aging deteriorations such as concrete compressive strength, corrosion, and tightness of anchor bolt, have a much smaller influence than crack. In order to manage the aging deterioration data collected through the seismic walkdown in effective and systematic, EDS(Evaluation of Deteriorated System) DB is ...
As a basic research to consider aging deterioration of the operating nuclear power plant to seismic fragility analysis, aging deteriorations occurring safety related equipment of both Kori unit 1 and Wolsung unit 1, are investigated in this study. First of all, 378 and 152 safety related equipment are selected at Kori unit 1 and Wolsung unit 1 respectively. Seismic review team including seismic capability engineer, is organized and seismic walkdown is carried out using the nondestructivetests. As a results of seismic walkdown, crack is a typical aging deterioration which can reduce the seismic safety of safety related equipment and the other aging deteriorations such as concrete compressive strength, corrosion, and tightness of anchor bolt, have a much smaller influence than crack. In order to manage the aging deterioration data collected through the seismic walkdown in effective and systematic, EDS(Evaluation of Deteriorated System) DB is ...
Non-destructive methods of diagnosis for detecting cable degradation by aging are being studied recently for improvement of electric wires and cables. This study examines degradation behaviors of cable sheath and insulation by combined accelerated aging tests applying thermal and radiation stresses simultaneously using a typical low voltage cable. According to experiments, elongation of cross-linked polyethylene insulation deteriorated at a faster rate than PVC sheath did under low doses below 50 Gy/h. Therefore, measurements using a time domain dielectric spectrometer (TDS) were carried out for the purpose of developing a method of degradation diagnosis of insulation. It was found that values of tan#delta# measured at very low frequencies below 0.1 Hz increase in pace with degradation of insulation reflecting the level of degradation more effectively than those measured at frequencies around the commercial frequency. In order to consider ...
The cold-worked Zr-2.5%Nb alloy is used as material for the pressure tubes in CANDU nuclear reactors. During the service life in reactor, diffusion of hydrogen and/or deuterium in the pressure tubes wall occur. Below a certain temperature, a stable hydride of zirconium is formed, as a brittle phase which can lead to catastrophic failures. For this reason, it is very important to be able to investigate the hydrogen effect on the micro structural properties of zirconium alloys. In the present paper a non-destructivetesting technique is used, known as ultrasonic spectral analysis. When an ultrasonic signal traverses a medium, the frequency components associated with the input signal are altered. By frequency analysing the reflected signals, it is possible to study and compare the material properties. The two major parameters measured in ultrasonic spectroscopy are the attenuation and the velocity of the waves. Attenuation is determined by the ...
Neutron radiography is a non-destructivetest method to examine a material by using the dependency of neutron attenuation on the nuclear characteristics of the atoms composing the object material. There are two categories of neutron radiography; static neutron radiography and dynamic neutron radiography. The static neutron radiography is a technique to observe a standing object by using a camera or a film cassette. The dynamic neutron radiography(DNR) is a technique to observe a moving object usually by using a camera. Depending on the camera frame rate, the dynamic neutron radiography is categorized into the real time neutron radiography(RTNR) and the high speed neutron radiography(HSNR). The frame rate for RTNR is 30 frames/s and that for HSNR is usually more that 500 frames/sec. Thus, RTNR is good for observing time-averaged phenomena and HSNR is good for observing instantaneous phenomena. DNR is a powerful tool for fluid visualization as ...
Neutron radiography is a non-destructivetest method to examine a material by using the dependency of neutron attenuation on the nuclear characteristics of the atoms composing the object material. There are two categories of neutron radiography; static neutron radiography and dynamic neutron radiography. The static neutron radiography is a technique to observe a standing object by using a camera or a film cassette. The dynamic neutron radiography(DNR) is a technique to observe a moving object usually by using a camera. Depending on the camera frame rate, the dynamic neutron radiography is categorized into the real time neutron radiography(RTNR) and the high speed neutron radiography(HSNR). The frame rate for RTNR is 30 frames/s and that for HSNR is usually more that 500 frames/sec. Thus, RTNR is good for observing time-averaged phenomena and HSNR is good for observing instantaneous phenomena. DNR is a powerful tool for fluid visualization as ...
This report compares the performance characteristics of /sup 10/B-lined and fission-neutron detectors in gamma-ray fluxes typical of the fields to be encountered during nondestructivetesting of irradiated light-water fuel assemblies stored in water. Using the optimum time constants for each of the /sup 10/B-lined detectors, the 0.25-in.-dia detector had a 5% loss in neutron count sensitivity at 7000 rad/h. Similarly, the 0.5-in.-dia detector had a 7% loss at 13,000 rad/h and the 1-in.-dia detector had a 5% loss in sensitivity at 1000 rad/h. Uranium-235 fission chambers were operated successfully in fields above 100,000 rad/h with no loss in neutron counting sensitivity. Shielding calculations were done to determine the appropriate shield thickness needed for a /sup 10/B-lined neutron detector to operate in a 50,000 rad/h field, typical of light-water-reactor spent-fuel assemblies stored in water. 7 refs., 4 figs., 9 tabs.
Eddy current inspection methods are widely used for the nondestructive evaluation (NDE) of tubular products. Specifically, the sensors and instrumentation are designed to detect and characterize changes in a material's electrical and magnetic properties produced by the presence of discontinuities. A recent major enhancement in eddy current inspection technology has been the development of computer interfacing for data collection, analysis, and display. This breakthrough has led to multiple-frequency testing, eddy current imaging, and automated data interpretation systems that significantly enhance both capabilities and reliability of the eddy current inspection. In addition to the clear advantages in data processing, computer interfacing also permits the design and creation of unique sensors that further enhance eddy current inspection capabilities. Perhaps the most promising area of computer interactive probe design is multiple ...
Faulting the feedwater for a 19-tube, model steam generator with 10 ppM of caustic once a week produced widespread shallow 25 to 75 micrometers (1 to 3 mils) intergranular attack (IGA) on alloy 600 tubes and an axial tube rupture at the steam-water interface after 4.8 years. An extensive investigation of the IGA damage found little correlation with major test variables beyond the indication that mill-annealed tubing was more susceptible to attack than stress-relieved tubing. The most likely cause of the tube rupture was caustic that concentrated to high levels in a porous scale on the tube at the liquid-vapor interface where there was a high available superheat. Nondestructive examination (NDE) eddy current probes underestimated the depth of IGA and were not sensitive to circumferential cracks less than 152 micrometers (6 mils) deep that were above and below the roll transition zones of tubes in the tubesheet.
The {sup 252}Cf-source-driven frequency analysis method can be used for measuring the subcritical neutron multiplication factor of arrays of LWR fuel and as little as a single PWR fuel assembly. These measurements can be used to verify the criticality safety margins of spent LWR fuel configurations and thus could be a means of obtaining the information to justify burnup credit for spent LWR transportation/storage casks. In addition, the data can be used to validate calculational methods for criticality safety. These measurements provide parameters that have a higher sensitivity to changes in fissile mass than neutron multiplication factor and thus serve as a better test of calculational methods. The analysis have also shown that measurement of the cross power spectral density (CPSD) between detectors on one side of a single fuel assembly and an internal or external {sup 252}Cf source driving the fission chain multiplication process can be used for ...
The DYMAC Communications System is part of a nuclear safeguards system called DYMAC - short for DYnamic Materials ACcountability - that gathers accountability information at the Los Alamos Scientific Laboratory (LASL) Plutonium Processing Facility. The communications system handles transmissions between data-entry terminals and nondestructive assay (NDA) instruments located in the facility, and a computer located in an adjacent building. System design emphasizes reliability rather than high speed to ensure the integrity of data transmissions. This manual is directed toward the person responsible for maintaining the DYMAC Communication System. It describes the components that make up the communications network, explains how they operate, and gives detailed information about all of the connections. Many of the system components are commercially available; some have been modified at LASL for DYMAC purposes; others were designed and fabricated at LASL. This manual ...
The procedure and operation-by-operation methods of the quality control of structural and fuel materials, mixed fuel pellets of UO_2-PuO_2, fuel element cans made of the AISI-316 steel and ready fuel elements are described as well as spacer wires (steel AISI-316), cases of fuel assemblies (FA) and completed FAs. The methods are used in manifacturing fuel elements and FAs for the FFTF reactor. The RDT standards that regulate the structure and functioning of the system of fuel element and FA production management are outlined. Destructive analytical methods characterized by sufficient accuracy but low productivity are noted to represent a considerable share of operations. Some specialized means of nondestructivetesting are developed, such as the gauge to measure the total plutonium content in a fuel element, neutron radiography deVice and a laser gauge to measure the FA dimensions. The experience gained served as a basis for designing the ...
The procedure and operation-by-operation methods of the quality control of structural and fuel materials, mixed fuel pellets of UO/sub 2/-PuO/sub 2/, fuel element cans made of the AISI-316 steel and ready fuel elements are described as well as spacer wires (steel AISI-316), cases of fuel assemblies (FA) and completed FAs. The methods are used in manifacturing fuel elements and FAs for the FFTF reactor. The RDT standards that regulate the structure and functioning of the system of fuel element and FA production management are outlined. Destructive analytical methods characterized by sufficient accuracy but low productivity are noted to represent a considerable share of operations. Some specialized means of nondestructivetesting are developed, such as the gauge to measure the total plutonium content in a fuel element, neutron radiography deVice and a laser gauge to measure the FA dimensions. The experience gained served as a basis for designing ...
This paper describes Fuji computed radiography (FCR) of Fuji Film for NDT (non-destructivetesting). Imaging plate (IP) is a two-dimensional detector of X-ray, and shows higher photographic sensitivity than X-ray film. The output emission of IP provides a good linear relationship to X-ray intensity in a wide intensity range. When this emission can be digitized, the X-ray intensity can be also digitized. IP is applied to NDT as an inspection using X-ray. FCR provides higher photographic sensitivity than the conventional X-ray film method, which results in one-fifth to one-twentieth of irradiation time. Images with stable density can be obtained independent of the intensity. Since IP has a wide dynamic range, the variation of X-ray intensity of 1:500 can be expressed in a single image by single shot. High density record including 1000 images can be done using a 5.25 inch optical disk through the digital image processing and the electrical ...
Neutron radiography and neutron radioscopy are rapidly becoming the valuable tools for nondestructivetesting and basic research. The Phoenix Memorial Laboratory has developed a neutron facility capable of both film neutron radiography and real time neutron radioscopy, and has used this facility to study several phenomena of interest to the researchers in many areas. Neutrons can be used for imaging the phenomena that X-ray cannot image, such as the presence, absence or movement of hydrogenous materials inside metals such as aluminum or steel. There are three basic methods for obtaining images using neutrons: high resolution film neutron radiography, real-time neutron radioscopy and transfer film neutron radiography. The neutron radiography facility at Phoenix Memorial Laboratory, the neutron radioscopic imaging systems, the neutron radiographic detectors, lubrication studies, spray imaging, flow in porous media, three-dimensional ...
Purpose: To evaluate a simple method for quantification of focal activity in bone scintigraphy (BS). Material and methods: The gamma camera was calibrated using a phantom. Quantitative bone scintigraphy (QBS) was performed on 11 men recently diagnosed with prostate cancer (PCa), for whom routine BS showed involvement of the skeleton. Following endocrine therapy for 4 to 8 months, a second QBS was performed. Changes in QBS values were then compared to changes in serum levels of prostate-specific antigen (PSA). Results: PSA response indicating regression of PCa was accompanied by a decrease in the QBS value in 8 of the 11 patients. The overall mean error of the QBS values was 15%. conclusion: QBS according to this method is a relatively simple procedure that might contribute to objective evaluation of therapeutic effects in skeletal metastases, although its validity must be tested in a larger clinical material.
Purpose: To evaluate a simple method for quantification of focal activity in bone scintigraphy (BS). Material and methods: The gamma camera was calibrated using a phantom. Quantitative bone scintigraphy (QBS) was performed on 11 men recently diagnosed with prostate cancer (PCa), for whom routine BS showed involvement of the skeleton. Following endocrine therapy for 4 to 8 months, a second QBS was performed. Changes in QBS values were then compared to changes in serum levels of prostate-specific antigen (PSA). Results: PSA response indicating regression of PCa was accompanied by a decrease in the QBS value in 8 of the 11 patients. The overall mean error of the QBS values was 15%. conclusion: QBS according to this method is a relatively simple procedure that might contribute to objective evaluation of therapeutic effects in skeletal metastases, although its validity must be tested in a larger clinical material
The purpose of this study was to investigate the feasibility of a simple deformable phantom as a QA tool for testing and validation of deformable image registration algorithms. A diagnostic thoracic imaging phantom with a deformable foam insert was used in this study. Small plastic markers were distributed through the foam to create a lattice with a measurable deformation as the ground truth data for all comparisons. The foam was compressed in the superior-inferior direction using a one-dimensional drive stage pushing a flat 'diaphragm' to create deformations similar to those from inhale and exhale states. Images were acquired at different compressions of the foam and the location of every marker was manually identified on each image volume to establish a known deformation field with a known accuracy. The markers were removed digitally from corresponding images prior to registration. Different image registration algorithms were tested using ...
We have exploited {open_quotes}progeny testing{close_quotes} to map quantitative trait loci (QTL) underlying the genetic variation of milk production in a selected dairy cattle population. A total of 1,518 sires, with progeny tests based on the milking performances of >150,000 daughters jointly, was genotyped for 159 autosomal microsatellites bracketing 1645 centimorgan or approximately two thirds of the bovine genome. Using a maximum likelihood multilocus linkage analysis accounting for variance heterogeneity of the phenotypes, we identified five chromosomes giving very strong evidence (LOD score {ge} 3) for the presence of a QTL controlling milk production: chromosomes 1, 6, 9, 10 and 20. These findings demonstrate that loci with considerable effects on milk production are still segregating in highly selected populations and pave the way toward marker-assisted selection in dairy cattle breeding. 44 refs., 4 figs., 3 ...
Improvements in electric submersible pumping systems have resulted in a demonstrated downhole running life of one year for low horsepower units operating in 180 C brine. The implementation of a prototype pressurized lubrication system to prevent brine intrusion and loss of lubricating oil from the motor and protector sections has been successfully tested. Second generation pressurized lubrication systems have been designed and fabricated and will be utilized in downhole production pumping tests during FY84. Pumping system lifetime is currently limited by available power cable designs that are degraded by high-temperature brine. A prototype metal-sheathed power cable has been designed and fabricated and is currently undergoing destructive and nondestructive laboratory testing. This cable design has the potential for eliminating brine intrusion into the power delivery system through the use of a ...
Conventional radiography has been the accepted nondestructivetesting (NDT) method used for many years to either ''accent'' or ''reject'' a field weld in the pipeline industry. However, conventional radiography requires the expense of film, developing chemicals, and manpower for film development. It also normally has a delay of 2 hours or more between when the weld was radiographed and when the radiographic film of the weld is available for interpretation. Over the last few years, a newer approach to performing radiographic testing, called ''realtime'' radiography, has been used in several different types of field inspection operations. The realtime radiography system forms the image with optical imaging in lieu of photographic film. Objectives of this project were: (Task 1) Integration of realtime x-ray system ...
A technique for quantitative determination of cephalothin and desacetylcephalothin in serum using a method based on high-pressure liquid chromatography is described. Both compounds were quantitatively...Full Text Available
Quantitative digital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitative image data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial dynamic range, signal-to-noise ratio and spatial resolution in the imaging system as well as developing ...
A graphic approach, terms a Genetic Activity Profile (GAP), was developed to display a matrix of data on the genetic and related effects of selected chemical agents. The profiles provide a visual overview of the quantitative (doses) and qualitative (test results) data for each chemical. Either the lowest effective dose or highest ineffective dose is recorded for each agent and bioassay. Up to 200 different test systems are represented across the GAP. Bioassay systems are organized according to the phylogeny of the test organisms and the end points of genetic activity. The methodology for producing and evaluating genetic activity profile was developed in collaboration with the International Agency for Research on Cancer (IARC). Data on individual chemicals were compiles by IARC and by the US Environmental Protection Agency (EPA). Data are available on 343 compounds selected from volumes 1-53 of the IARC ...
Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).
Non-destructive methods for measuring the remaining anticorrosive or antioxidative ability of coatings are investigated. For anticorrosive chromium coatings the increasing ferromagnetism caused by loss of chromium is measured by a permeability probe. Measured values on blades after operation are correlated with the progress of corrosion as determined by metallographic methods. For antioxidative aluminum coatings the diminishing layer thickness is taken as indication for the exhaustion of their protection ability. The layer thickness is measured eddy current probes, especially developed for this application.
Damage survey of protective coats of modern gas turbine blade shows that most damages are not due to classic wear mechanisms such as oxydation or high-temperature corrosion but caused by foreign bodies, poor coating during manufacturing, or operation-caused cracks. Mere visual inspection of cracks is often not sufficient to tell whether cracks are superficial or whether they have already progressed into the base material. Non-destructive methods such as ultrasonic inspection or eddy-current testing are helpful tools but there is not yet a fully matured testing concept at hand. Metallographical tests can give important information about crack mechanisms and thermal, chemical and mechanical stresses.(orig.) [German] Die Schadenerfahrung mit Schutzschichten moderner Gasturbinenschaufeln zeigt, dass die meisten Schaeden nicht auf die klassischen Verbrauchsmechanismen wie Oxydation und ...
Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more ...
Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. Measurement of the ...
The study of randomness in low-dimensional quantum antiferromagnets is at the forefront of research in the field of strongly correlated electron systems, yet there have been relatively few experimental model systems. Complementary neutron scattering and numerical experiments demonstrate that the spin-diluted Heisenberg antiferromagnet La2Cu(1-z)(Zn,Mg)zO4 is an excellent model material for square-lattice site percolation in the extreme quantum limit of spin one-half. Measurements of the ordered moment and spin correlations provide important quantitative information for tests of theories for this complex quantum-impurity problem.
An apparatus was designed and built for the purpose of exposing samples of solid polymers to varying temperatures, atmospheres and stress levels while quantitatively recording the resulting chemiluminescence. Preliminary data were acquired with this apparatus that show a correlation between an enhanced chemiluminescence signal at a low level of applied stress and a decrease in tensile strength for the most commonly used epoxy resin in high performance fiber composites, TGMDA DDS. The studies with cellular silicone cushions (which are used to accommodate thermal expansion and contraction) have defined the temperature regimes in which accelerated aging tests are valid for extrapolation to ambient temperature. Preliminary data on Kevlar fibers is also discussed.
Light microscopy was used to analyze the effects of added catalyst at different conditions (temperature and reaction times) in liquefaction testing of a low pyritic sulfur bituminous coal. Quantitative changes in vitrinite/vitroplast reflectance of coal and liquefaction residues were shown to be useful markers in analyzing and understanding the role of catalyst during the initial stage of coal particle hydrogenation. Lower reflectance values corresponded to increased conversions up to about the 60 min and 375{degrees}C experimental conditions. Microscopical observation of liquefaction residues also revealed the presence of `wall scales` of varying width.
Indirect evaporative air coolers that use air-to-air plate-type heat exchangers show good promise (compared with compression air-conditioning systems) of extending the energy savings from arid, low-humidity areas to more widespread climatic conditions. However, no systematic experiment had been done concerning the effect of the wettability of aluminum plates on the effectiveness of the indirect evaporative cooling system. In this study, a testing apparatus was built where only one secondary channel and two primary channels were used so that different surfaces could be easily tested to determine the system`s effectiveness and the heat transfer coefficient. The advantage of this experimental apparatus is that plates of the heat exchanger can be easily changed in the test section instead of fabricating a complete heat exchanger for each test. A dynamic contact analyzer was used to ...
The Four years of the IMPACT, 'Integrated Modular Plant Analysis and Computing Technology', project Phase 1 have been completed. The verification study of Severe Accident Analysis Code SAMPSON prototype developed in Phase 1 was conducted in two steps. First, each analysis module was run independently and analysis results were compared and verified against separate-effect test data with good results. Second, with the Simulation Supervisory System, up to 11 analysis modules were executed concurrently in the parallel environment (currently, NUPEC uses IBM-SP2 with 72 process elements), to demonstrate the code capability and integrity. The target plant was Surry as a typical PWR and the initiation events were a 10-inch cold leg failure. The analysis is divided to two cases; one is in-vessel retention analysis when the gap cooling is effective (In-vessel scenario test), the other is analysis of phenomena event is extended to ex-vessel due to the ...
Results from a heavily fouled 19 tube C-E model boiler test to investigate the potential for egg crate corrosion in aggressively fouled AVT chemistry are reported. Substantial support plate and egg crate corrosion was produced in this test. Carbon steel drilled support plates exhibited extensive denting which resulted in flow hole ligament cracking. Corrosion of the carbon steel egg crate, through-wall at areas of tube contact, resulted in denting of the Alloy 600 heat transfer tubes. Corrosion performance of the 409 stainless steel egg crate was improved compared to the carbon steel egg crate although localized through-wall corrosion was noted. The results from the above test and previously reported tests were compared based on the following simplifying assumptions: maximum dent size and/or corrosion penetrations utilized, average bulk water chloride concentrations, pilling bedworth ratios, pot and ...
For a reliable design against fatigue failure of high-temperature components of different types of the heat resistant material Alloy 800, verified parameters of the low-cycle fatigue (LCF) behaviour are required. These parameters were obtained by a scatterband evaluation of the results of low-cycle fatigue tests, using a computerized data bank which includes all available actual data sets. The results of the evaluation are presented as mean fatigue curves with the upper and lower boundary limits of the scatterbands. For the type Alloy 800 in the recrystallization annealed condition, the results cover a temperature range from 20 to 750deg C; for the solution annealed types they cover a temperature range from 20 to 950deg C. Specimens tested in HTR helium at high temperatures had longer lives than specimens tested in air. This effect was represented quantitatively by the ratio of the total strain ranges ...
Laser-Induced Breakdown Spectroscopy was selected by NASA as part of the ChemCam instrument package for the Mars Science Laboratory rover to be launched in 2009. ChemCam's Laser-Induced Breakdown Spectroscopy instrument will ablate surface coatings from materials and measure the elemental composition of underlying rocks and soils at distances from 1 up to 10 m. The purpose of our studies is to develop an analytical methodology enabling identification and quantitative analysis of these geological materials in the context of the ChemCam's Laser-Induced Breakdown Spectroscopy instrument performance. The study presented here focuses on several terrestrial rock samples which were analyzed by Laser-Induced Breakdown Spectroscopy at an intermediate stand-off distance (3 m) and in an atmosphere similar to the Martian one (9 mbar CO{sub 2}). The experimental results highlight the matrix effects and the measurement inaccuracies due to the noise accumulated ...
Laser-Induced Breakdown Spectroscopy was selected by NASA as part of the ChemCam instrument package for the Mars Science Laboratory rover to be launched in 2009. ChemCam's Laser-Induced Breakdown Spectroscopy instrument will ablate surface coatings from materials and measure the elemental composition of underlying rocks and soils at distances from 1 up to 10 m. The purpose of our studies is to develop an analytical methodology enabling identification and quantitative analysis of these geological materials in the context of the ChemCam's Laser-Induced Breakdown Spectroscopy instrument performance. The study presented here focuses on several terrestrial rock samples which were analyzed by Laser-Induced Breakdown Spectroscopy at an intermediate stand-off distance (3 m) and in an atmosphere similar to the Martian one (9 mbar CO2). The experimental results highlight the matrix effects and the measurement inaccuracies due to the noise accumulated when low signals are ...
Advances in the theory and practice of stress corrosion cracking (SCC) are reviewed for the period 1965-1990. The proceedings of two landmark conferences are used as a basis for discussion: Ohio State University (1967) and Kohler, WI (1988). The discussion is developed around the following topics: metal-environment combinations, testing, fractography, metallurgical aspects, electrochemical aspects and crack chemistry, mechanisms, and prediction and mitigation. It is concluded that the main developments since 1967 are the recognition of the lack of specificity of SCC environments, the use of slow strain rate and fracture mechanics testing, quantitative SEM fractography, studies of grain boundary structure and compositions, transient electrochemistry of bare metal surfaces, measurement and modelling of crack chemistry, elaboration of several SCC models, including slip-dissolution and film induced cleavage, and mitigation by ...
The authors have performed I-123 IMP single- photon emission CT (SPECT) brain imaging on seven mildly demented patients with acquired immunodeficiency syndrome (AIDS) and on seven normal subjects. Pixel-intensity histograms have been analyzed for the fraction of pixels in the lowest quartile of the intensity range. This fraction (F) averaged 17.7% (standard deviation [SD] = 4.3) in the AIDS group and 12.6 (SD = 4.7) in the normal group (P <.05). Regression analysis of neuropsychological testing (NPT) scores vs F yielded a correlation coefficient of.71. The presence or degree of atrophy did not correlate with F or NPT scores.
The purpose of this study is to investigate on the experimental verification analysis for the pipe whip problems and to obtain the quantitative evaluation technologies for the design technique of pipe whip restraints. These will contribute to the advance of nuclear regulatory technologies and enhance nuclear power plant safety. This study presents the experimental and transient analytical results of pipe whip tests using the 4', 6' diameter pipe and U-shaped restraints. In the tests, the effects of the overhang length, clearance, impact height on the pipe whip behavior of the pipe-restraints were investigated. The transient impact analysis of the pipe-restraint system was conducted by the finite element program ABAQUS. The applicability of the ABAQUS program to the pipe whip analysis is made clear through this analysis.
The diffusion characteristics of water in polymer materials have been studied for a few decades. Several methods have been developed to provide water diffusion characteristics as a function of time, temperature, pressure, or thickness of polymer. Unfortunately, most of these methods give the amount of water absorbed as a function of weight versus time at given environmental conditions. Concentration profiles of the water diffusion through the polymer have been unobtainable by these established methods. Neutron radiography is a method of non-destructivetesting that has grown rapidly over the past ten years and is capable of giving these concentration profiles. Epoxy is one of the most commonly used polymers for which water diffusion information is important. In the automotive industry, epoxy is used both as a sealant and a bonder to prevent water from getting inside structures and causing corrosion. To prevent this corrosion, it is important to ...
Studies conducted at the Pacific Northwest National Laboratory (PNNL) in Richland, Washington have focused on developing and evaluating the reliability of nondestructivetesting (NDT) approaches for coarse-grained stainless steel reactor components. The objective of this work is to provide information to the United States Nuclear Regulatory Commission (NRC) on the utility, effectiveness and limitation of NDT techniques as related to inservice testing of primary system piping components in pressurized water reactors. We examined cast stainless steel pipe specimens containing thermal and mechanical fatigue cracks located close to the weld roots and having inner and outer diameter surface geometrical conditions that simulate several water reactor primary piping configurations. In addition, segments of vintage centrifugally cast piping were examined to characterize the inherent acoustic noise and scattering caused by grain ...
To establish test specific normal limits for quantitative analysis of uptake and washout of /sup 201/Tl after dipyridamole infusion combined with low level exercise, 20 healthy volunteers were studied with low likelihood of coronary artery disease (CAD) assessed by a stepwise probability analysis based on age, sex, symptoms, resting electrocardiogram, and exercise electrocardiography. Likelihood of CAD in these volunteers was calculated as less than or equal to 1%. After dipyridamole infusion combined with low level exercise, one volunteer complained of headache; no other side effects were observed. There were no chest pain complaints. Maximal hemodynamic changes were achieved during the 6th and 7th min of the test. No ST segment depression was recorded. Visual analysis of the /sup 201/Tl scintigrams was normal in all volunteers. Mean regional washout at 4 h was 44.37%+-2.11%. The regional washout in the 70/sup 0/ LAO view ...
Under Section 5 of the Toxic Substances Control Act (TSCA), manufacturers must notify the US Environmental Protection Agency (EPA) 90 days before manufacturing, processing, or importing a new chemical substance. This is referred to as a premanufacture notice (PMN). The PMN must contain certain information including chemical identity, production volume, proposed uses, estimates of exposure and release, and any health or environmental test data that are available to the submitter. Because there is no explicit statutory authority that requires testing of new chemicals prior to their entry into the market, most PMNs are submitted with little or no data. As a result, EPA has developed special techniques for hazard assessment of PMN chemicals. These include (1) evaluation of available data on the chemical itself, (2) evaluation of data on analogues of the PMN, or evaluation of data on metabolites or analogues of metabolites of the PMN, (3) use of ...
Investigations were made on the biodegradability and bacterial toxicity of chemicals. The intention was to obtain data necessary for estimating and judging the behaviour of these chemicals during aerobic biological waste water treatment. The course of biodegradation and toxicity with time and concentration could be measured, quantified and described. As test procedure, the respirometric dilution method was used. This method is based on a die away test with continuous measuring of the oxygen used for biochemical oxidation processes. The course of the oxygen demand with time and concentration shows the biodegradation and toxicity patterns of the tested chemical. A variety of household and industrial chemicals were investigated. One group of substances were microbiocides, some of which showed toxic effects at concentrations less than 20 mg/l while others were biodegradable even at concentrations of 200 mg/l. Another group of ...
A series of 27 reflood experiments has been carried out in a full-length electrically heated rod bundle facility. The primary objective of these tests was to study the effects of a simultaneous upper plenum and downcomer coolant injection and to provide data for the verification of computer codes. The experimental results indicate that an upper plenum injection alone cools the test rods slowly, a simultaneous coolant injection to the downcomer improves cooling significantly, and a downcomer injection alone cools the test rod bundle best if the total value of the coolant flow rate is the same in these three different cases. If the coolant injected to the upper plenum increases the total flow rate, the quench time of the test rods decreases at all elevations. Quenching time and clad temperature histories calculated with the computer codes NORCOOL-I and FLOOD4 are in a reasonable ...
Skin sensitization is the most commonly reported occupational illness, causing much suffering to a wide range of people. Identification and labeling of environmental allergens is urgently required to protect people from skin sensitization. The guinea pig maximization test (GPMT) and murine local lymph node assay (LLNA) are the two most important in vivo models for identification of skin sensitizers. In order to reduce the number of animal tests, quantitative structure-activity relationships (QSARs) are strongly encouraged in the assessment of skin sensitization of chemicals. This paper has investigated the skin sensitization potential of 162 compounds with LLNA results and 92 compounds with GPMT results using a support vector machine. A particle swarm optimization algorithm was implemented for feature selection from a large number of molecular descriptors calculated by Dragon. For the LLNA data set, the classification ...
A prototype trumpet type nonimaging secondary concentrator was designed and fabricated for use with the Cummins Power Generation (CPG) 7.5 kW{sub e} dish-Stirling system. A set of operational tests was carried out with a high temperature heat pipe receiver and gas-gap calorimeter. These tests have successfully alleviated any operational concerns about the effectiveness of active water cooling for such devices. The authors obtained over two full days of testing with the cavity receiver operating at its design temperature of 660 C while the trumpet throat temperature remained {approx_equal} or less than 100 C. In addition, these tests have shown that the thermal isolation of the trumpet from the hot receiver is very effective. Highly variable insolation, instabilities in the temperature controller on the calorimeter, and a poor match between the optical quality of the primary and the design of the trumpet ...
Genetic analysis of resistance of plant introduction (PI) 438489B to soybean cyst nematode (SCN) have shown that this PI is highly resistant to many SCN HG types. However, validation of the previously detected quantitative trait loci (QTL) has not been done. In this study, 250 F2:3 progeny of a Magellan (susceptible)??PI 438489B (resistant) cross were used for primary genetic mapping to detect putative QTL for resistance to five SCN HG types. QTL confirmation study was subsequently conducted using F6:7 recombinant inbred lines (RILs) derived from the same cross. Simple sequence repeat (SSR) and single nucleotide polymorphism (SNP) markers were employed for molecular genotyping. Interval mapping (IM), permutation tests, cofactor selection, and composite interval mapping (CIM) were performe...
Quantitative bone scintigraphy was performed on 23 white females with post-menopausal osteoporosis and vertebral compression fractures. These patients were then entered into a randomized, double-blind clinical trial or sodium fluoride therapy (NaF=14, placebo=9) which included repeat bone scintigraphy every six months. Scintigraphic images were acquired for 500K counts per image over the total body with computer acquisition over the posterior thoracic and lumbar spine. Images were obtained on a wide field-of-view gamma camera two hours after injecting 15 mCi of Tc-99m MDP. Data analysis showed a significant reduction in the activity ratio of abnormal vertebral body to normal vertebral body in those patients treated with sodium fluoride (paired t-test p=0.0095). No significant change was observed in the control group of (p=0.142). These results suggest that sodium fluoride therapy promotes more rapid healing of osteoporotic vertebral fractures. ...
Since August 2000, the stock market in the USA as well as most other western markets have depreciated almost in synchrony according to complex patterns of drops and local rebounds. In (Quantitative Finance 2 (2002) 468), we have proposed to describe this phenomenon using the concept of a log-periodic power law antibubble, characterizing behavioral herding between investors leading to a competition between positive and negative feedbacks in the pricing process. A monthly prediction for the future evolution of the US S&P 500 index has been issued, monitored and updated in (http://www.ess.ucla.edu/faculty/sornette/prediction/index.asp#prediction), which is still running as the article goes to press. Here, we test the possible existence of a regime switching in the US S&P 500 antibubble. First, we find some evidence that the antibubble has exhibited a transition in log-periodicity described by a so-called second-order log-periodicity. ...
This volume contains 5 appendices. Title listing are: technologies for recovery of transuranics; nondestructive assay of TRU contaminated wastes; miscellaneous waste characteristics; acceptance criteria for TRU waste; and TRU waste treatment technologies.
Terminal-differential algorithm for identification of local nonhomogeneities in items under control is developed on the basis of measurements of X-ray or gamma-radiation weakening. The algorithm may be applied by developing radiation schemes of nondestructive control, identifying inadmissible inclusions in the object under study
Papers are presented in the areas of: Medical Technologies; Non-Destructive Evaluation; Applications of Signal/Image Processing; Laser Guide Star and Adaptive Optics; Computational Electromagnetic, Acoustics and Optics; Micro-Impulse Radar Processing; Optical Applications; TANGO Space Shuttle.
Optimum conditions for the rapid, efficient, nondestructive determination of rubber producing potential in guayule (Parthenium argentatum) were established. The rubber producing potential...Full Text Available
To analyse the binding of sugar chains to proteins, viruses and cells, the surface plasmon resonance (SPR) technique is very convenient and effective because it is a real-time, non-destructive detection...Full Text Available
The U.S. Department of Energy (DOE) has been developing a nuclear waste disposal facility, the Waste Isolation Pilot Plant (WIPP), located approximately 42 km east of Carlsbad, New Mexico. The WIPP is designed to demonstrate the safe disposal of transuranic wastes produced by the defense nuclear-weapons program. Pefiormance assessment analyses (U.S. DOE, 1996) indicate that human intrusion by inadvertent and intermittent drilling for resources provide the only credible mechanisms for significant releases of radionuclides horn the disposal system. These releases may occur by five mechanisms: (1) cuttings, (2) cavings, (3) spallings, (4) direct brine releases, and (5) long- term brine releases. The first four mechanisms could result in immediate release of contaminant to the accessible environment. For the last mechanisq migration pathways through the permeable layers of rock above the Salado are important, and major emphasis is placed on the Culebra Member of the Rustler Formation ...
This is the Fiscal Year 1995 Annual Report for the Advanced Manufacturing Science and Technology (AMST) sector of Los Alamos Tactical Goal 6, Industrial Partnering. During this past fiscal year, the AMST project leader formed a committee whose members represented the divisions and program offices with a manufacturing interest to examine the Laboratory`s expertise and needs in manufacturing. From a list of about two hundred interest areas, the committee selected nineteen of the most pressing needs for weapon manufacturing. Based upon Los Alamos mission requirements and the needs of the weapon manufacturing (Advanced Design and Production Technologies (ADaPT)) program plan and the other tactical goals, the committee selected four of the nineteen areas for strategic planning and possible industrial partnering. The areas selected were Casting Technology, Constitutive Modeling, Non-DestructiveTesting and Evaluation, and Polymer Aging and Lifetime ...
An eddy current inspection has been applied for a pre-service and in-service examination of a steam generator in nuclear power plants. The experience from the inspection of steam generators showed that many plants had an excessive number of tubes with eddy current noise signals over several hundreds, which originated from manufacturing anomalies. The plants in U.S suffered significant downstream inspection costs, history reviews, and diagnostic testing because some signals resembled flaws and others masked a flaw. These lessens learned resulted in issuing the guidelines for steam generator tubing specifications and repair, in order to reduce the number of anomalous signals in the tubes and also to provide the requirement of a signal to noise ratio by applying a field type examination with bobbin coil eddy current probes at a manufacturing process. Besides the noise signals of a bobbin coil eddy current probe from manufacturing anomalies, the excessive background ...
This report is a summary of the Steam Generator Group Project progress for 1985. Statistical analyses are presented of data from nondestructive examination (NDE) round robin tests that were performed on the Surry generator in 1984. In the first round robin, teams acquired and analyzed their own data on a selected 10% subset of tubes. In the second round robin, analysts from each participating team analyzed identical sets of data which were provided to them by the Project. Results from several examinations utilizing advanced/alternate NDE technologies including alternate eddy current probes and techniques, ultrasonics, and profilometry are also reported. Criteria are listed for selecting tube specimens that will be removed from the generator. A sampling plan based on these criteria is detailed graphically in the report. The initial steps that have been taken to carry out the plan are described; tooling fabricated for the sample removals is ...
This report is a summary of the Steam Generator Group Project progress for 1985. Statistical analyses are presented of data from nondestructive examination (NDE) round robin tests that were performed on the Surry generator in 1984. In the first round robin, teams acquired and analyzed their own data on a selected 10% subset of tubes. In the second round robin, analysts from each participating team analyzed identical sets of data which were provided to them by the Project. Results from several examinations utilizing advanced/alternate NDE technologies including alternate eddy current probes and techniques, ultrasonics, and profilometry are also reported. Criteria are listed for selecting tube specimens that will be removed from the generator. A sampling plan based on these criteria is detailed graphically in the report. The initial steps that have been taken to carry out the plan are described; tooling fabricated for the sample removals is ...
Many electric power utilities are currently employing machine condition monitoring technologies as a means of reducing forced outages and controlling repair costs. These condition monitoring technologies are a set of {open_quotes}tools{close_quotes} to help maintenance and operations personnel identify and repair machinery problems before catastrophic failure occurs. In this way, the analysis of this data becomes a vital link in the daily operation of the plant. Machinery vibration analysis, machinery balancing and alignment, motor current testing, periodic thermography surveys, analysis of lubrication oil samples, performance monitoring, chemistry monitoring, ultrasonic leak detection surveys, and non-destructive inspections are some of the technologies available to perform this condition monitoring. However, even for a small or medium size plant, the sheer volume of data provided by applying all or some of these technologies can be ...
A new eddy current array probe has been implemented as a straightforward and promising technique for detection of outer diameter (OD) surface-breaking cracks on the extrados of feeder bends. The design is based on previous work performed at AECL, which had demonstrated that eddy current probes with laterally displaced transmit-receive coils can overcome some of the limitations of inspecting ferritic steel components for surface-breaking cracks. The Feeder Integrity Joint Program-CANDU Owners Group Inc. (FIJP-COG) Non-Destructive Evaluation (NDE) Team members commissioned AECL to work in collaboration with the probe manufacturer ZETEC, to develop a field usable eddy current array probe. The objective was to acquire a technique with the following capabilities: fast scanning non-contact inspection technique for surface breaking discontinuities; full inspection of the bend extrados OD surface in a single scan; ability to inspect first and second bends with similar ...
A new eddy current array probe has been implemented as a straightforward and promising technique for detection of outer diameter (OD) surface-breaking cracks on the extrados of feeder bends. The design is based on previous work performed at AECL, which had demonstrated that eddy current probes with laterally displaced transmit-receive coils can overcome some of the limitations of inspecting ferritic steel components for surface-breaking cracks. The Feeder Integrity Joint Program-CANDU Owners Group Inc. (FIJP-COG) Non-Destructive Evaluation (NDE) Team members commissioned AECL to work in collaboration with the probe manufacturer ZETEC, to develop a field usable eddy current array probe. The objective was to acquire a technique with the following capabilities: fast scanning non-contact inspection technique for surface breaking discontinuities; full inspection of the bend extrados OD surface in a single scan; ability to inspect first and second bends with similar ...
US Department of Energy methods used for characterization of contact-handled transuranic (CH-TRU) waste prior to shipment to the Waste Isolation Pilot Plant (WIPP) are described and listed by contractor site. The methods described are part of the certification process. All CH-TRU waste must be assayed for determination of fissile material content and decay heat values prior to shipment and prior to storage on-site. Both nondestructive assay (NDA) and destructive assay methods are discussed, and new NDA developments such as passive-action neutron (PAN) crate counter improvements and neutron imaging are detailed. Specifically addressed are assay method physics; applicability to CH-TRU wastes; calibration standards and implementation; operator training requirements and practices; assay procedures; assay precision, bias, and limit of detection; and assay limitation. While PAN is a new technique and does not yet have established American Society for ...
US Department of Energy methods used for characterization of contact-handled transuranic (CH-TRU) waste prior to shipment to the Waste Isolation Pilot Plant (WIPP) are described and listed by contractor site. The methods described are part of the certification process. All CH-TRU waste must be assayed for determination of fissile material content and decay heat values prior to shipment and prior to storage on-site. Both nondestructive assay (NDA) and destructive assay methods are discussed, and new NDA developments such as passive-action neutron (PAN) crate counter improvements and neutron imaging are detailed. Specifically addressed are assay method physics; applicability to CH-TRU wastes; calibration standards and implementation; operator training requirements and practices; assay procedures; assay precision, bias, and limit of detection; and assay limitation. While PAN is a new technique and does not yet have established American Society for ...
Non-destructive Evaluation (NDE) plays a major role in ensuring the safe and reliable operation of PHWRs which are the mainstay of India's nuclear power programme. An important in-service inspection (ISI) requirement in these reactors is carried out through Eddy Current Testing (ECT) of the pressure tube (PT)/calandria tube (CT) assemblies. The material of construction of these assemblies is zircaloy-2. The two main objectives of this ISI are the detection of garter spring between CT and PT and the profiling of gap between CT and PT. The paper discusses the work carried out at the authors' laboratory on the development of ECT probes for ISI of PT/CT assemblies. Emphasis has been given on the work done on the design and optimisation of the probes using computer modeling. A 2-D finite element code has been developed for this purpose. The code is developed around a diffusion equation which can be derived from Maxwell's equations governing the ...
Lappeenranta University of Technology (LTKK) and VTT Energy carried out a series of preliminary tests in 1999 to study the behavior of noncondensable (NC) gases in VVER geometry. The tests aimed at studying the effect of NC gases on system thermal-hydraulics and on heat transfer in a horizontal steam generator (HSG). The system behavior can be affected by hydrogen produced in the core in case of a severe accident, by nitrogen from hydro-accumulators released into the primary circuit in case of a loss-of-coolant accident (LOCA) and more generally by any NC gas in all cases where cooling is ensured by natural circulation. A secondary objective of the tests - the first series of tests ever performed with NC gas with PACTEL - was to find out, if the instrumentation of PACTEL was adequate for this type of tests and if it was functioning properly. This paper presents the measured and ...
Thermo-hygro-rheology of wood-adhesive systems plays an important role during the hot pressing process of wood based composites. The principal objective of this research is to quantitatively study the thermo-hygro rheological characteristics of wood-adhesive systems used in such composites. This is with a view to providing material characteristics which may be used in simulation models of industrial hot-pressing operations. For this purpose, a specially designed miniature hot press system mounted on a servo-hydraulic testing machine was used to compress pre-formed fiber networks. The environment for each test was maintained uniform throughout the specimen by pre-treating it inside the system until the desired conditions of temperature and moisture were achieved. Experiments were conducted under a range of test conditions of load (1 to 6 MPa), temperature (25 to 150C) and moisture content (0 to 16%). A ...
A multicentre evaluation of the urine test strip analyser Super Aution-4220 was carried out in six laboratories. The analytical performance of the instrument with regard to imprecision, linearity, detection limit, drift, carry-over and method comparison was studied. Using the Aution stick 8 test strip the pH, glucose, protein, ketones, bilirubin, blood, urobilinogen and leukocyte esterase were analysed. Specific gravity measurements were performed by refractive index method. Within-run and between-run imprecision determined at three levels of analyte were good. No carry-over was observed. Obtained results were linear through all the described analytical range. No significant drift was detected. Method comparison with some quantitative methods was performed and showed a good correlation with most of the analytes. The study of interferences showed minor interferences by common therapeutic drugs with the measurement of some ...
As the first step for development of the corrosion resistant superheater tube materials of 500 C, 100 ata used in high efficient waste-to-energy plants, field corrosion tests of six conventional alloys were carried out at metal temperatures of 450 C and 550 C for 700 and 3,000 hours in four typical Japanese waste incineration plants. The test results indicate that austenitic alloys containing approximately 80 wt% [Cr+Ni] show excellent corrosion resistance. When the corrosive environment is severe, intergranular corrosion of 40{approximately}200 {micro}m depth occurs in stainless steel and high alloyed materials. It is confirmed quantitatively that corrosion behavior is influenced by environmental corrosion factors such as Cl concentration and thickness of deposits on tube surface, metal temperature, and flue gas temperature. The excellent corrosion resistance of high [Cr+Ni+Mo] alloys such as Alloy 625 is explained by the ...
As the first step for development of the corrosion resistant superheater tube materials of 500 C, 100 ata used in high efficient waste-to-energy plants, field corrosion tests of six conventional alloys were carried out at metal temperatures of 450 C and 550 C for 700 and 3,000 hours in four typical Japanese waste incineration plants. The test results indicate that austenitic alloys containing approximately 80 wt% [Cr+Ni] show excellent corrosion resistance. When the corrosive environment is severe, intergranular corrosion of 40#approx#200 microm depth occurs in stainless steel and high alloyed materials. It is confirmed quantitatively that corrosion behavior is influenced by environmental corrosion factors such as Cl concentration and thickness of deposits on tube surface, metal temperature, and flue gas temperature. The excellent corrosion resistance of high [Cr+Ni+Mo] alloys such as Alloy 625 is explained by the stability ...
We have recently introduced several important improvements in the measurement of distillation curves for complex fluids. The modifications include a composition-explicit data channel for each distillate fraction (for both qualitative and quantitative analysis) and corrosivity assessment of each distillate fraction. The composition-explicit information is achieved with a new sampling approach that allows precise qualitative as well as quantitative analyses of each fraction, on the fly. We have applied the new method to a variety of fluids, including simple n-alkanes, rocket propellant, gasoline, jet fuels, and a hydrocarbon fluid made corrosive with dissolved hydrogen sulfide. In the current contribution, we present the application of the advanced distillation curve method to two samples of crude oil. A primary motivation behind the work is to precisely measure the distillation curves of these oils using our advanced distillation apparatus; ...
Biomarkers are biometric measurements that provide critical quantitative information about the biological condition of the animal or individual being tested. In drug safety studies, established toxicity biomarkers are used along with other conventional study data to determine dose-limiting organ toxicity, and to define species sensitivity for new chemical entities intended for possible use as human medicines. A continuing goal of drug safety scientists in the pharmaceutical industry is to discover and develop better trans-species biomarkers that can be used to determine target organ toxicities for preclinical species in short-term studies at dose levels that are some multiple of the intended human dose and again later in full development for monitoring clinical trials at lower therapeutic ...
Quantitative, experimentally based assessments of the biases of the methods used to develop the neutronics design of the FTR are presented together with brief descriptions of the design methods. Uncertainties in biases have been established that are sufficiently small to allow a high degree of confidence in the nuclear design. Experimental data for these assessments have been developed in full-scale zero-power mockups of the final design of the reactor, except for Doppler data from SEFOR. Temperature, power coefficient, and stability methods evaluations are necessarily deferred to acceptance testing during initial startup of the FTR. Sodium voiding and small sample worths continue to be the technical areas of greatest complexity with least experiment-theory correlation. Critical mass, Doppler effects, control rod worth, and spatial power distribution have generally good experiment-theory correlations.
In order to improve the reliability of PWR steam generators, we have performed research to improve the tubing material and tube-support-plate configuration, based on our wide operating experience, and have developed and verified Alloy TT690 as the optimum tubing material and the BEC (Broached Egg Crate) type tube-support design. In the research, we have studied the metallurgical mechanism of the alloy to improve its corrosion resistance, evaluated corrosion susceptible region quantitatively, estimated the actual environment in a steam generator and confirmed the reliability by a model boiler test over a long period. It has been verified that the steam generator with the latest design has higher reliability with respect to the corrosion resistance of tubes. (author).
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain quantitative information on the object being imaged.
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain quantitative information on the object being imaged. (orig.).
The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.
Real-time neutron radiography was demonstrated to be a viable and useful tool in studying water flow in unsaturated media. The experiment was designed to test the method for following water flow. The wetting front advance, water-flow patterns, and neutron attenuation density were observed in a 7.7-cm diameter sand column. The advance was fit with a simple i = A t/sup B/ equation yielding an excellent correlation. Theoretical calculations presented estimate the minimum and maximum detectable water content in various sizes of columns. The ability of real-time neutron radiography to allow both qualitative and quantitative spatial and time measurements to be made in an nonintrusive manner was demonstrated.
Real-time neutron radiography was demonstrated to be a viable and useful tool in studying water flow in unsaturated media. The experiment was designed to test the method for following water flow. The wetting front advance, water-flow patterns, and neutron attenuation density were observed in a 7.7-cm diameter sand column. The advance was fit with a simple i = A t/sup B/ equation yielding an excellent correlation. Theoretical calculations presented estimate the minimum and maximum detectable water content in various sizes of columns. The ability of real-time neutron radiography to allow both qualitative and quantitative spatial and time measurements to be made in an nonintrusive manner was demonstrated.
Through the dedicated collaborative efforts of many individuals interested in supporting local education, computer laboratories were established at two urban high schools. The purchasing and implementation of the project was handled by the Alliance for Education, a local non-profit education advocate. Funds were supplied by the Air Force as part of a 3-year research activity utilizing artificial intelligence technology to tutor 9th grade students. NCR (now AT7T Global Information Solutions) corporate leaders provided the computers and network equipment at a considerable savings to the project. Each lab is a state-of-the-art facility with air-conditioning, carpeting, special computer tables, computer projection screens, and on-site technical support. Student and teacher enthusiasm toward the project has been gratifying and quantitative results are currently being evaluated for both attitude, skills, and state proficiency tests.
The purpose of this study was to validate through natural exposure a cut-off level of varicella zoster IgG as protective against infection with varicella zoster virus (VZV). Laboratory testing to determine VZV immune status of pregnant women exposed to varicella is recommended. Quantitative assays are now available which are sensitive and specific. More than 200 consecutive requests for screening in pregnant patients with recent varicella contacts were followed-up by questionnaire. DiaSorin LIAISON and VZV time resolved fluorescence immuno assay (VZV TRFIA) were used to measure VZV antibody level. One hundred fifty out of 209 (72%) questionnaires were returned; 14 patients developed varicella, 129 did not and seven were not known. Patients who had been given VZIG and developed varicella on...
The flame retardancy of polybutylene terephthalate (PBT) was studied focusing on the effect of various oxides. Thermo-gravimetric analysis, pyrolysis/gas chromatography/mass spectrometry, and elemental analysis (EA) were used to analyze the flame retardancy, which were observed through the UL-test and a cone calorimeter. Many oxides influenced the flame retardancy and some of them could suppress the flammability of PBT. In particular, the blended-PBTs with ZnO and V2O5 accelerated the degradation and the edges of oxygen consumption were shorter than neat-PBT although the flammability became poorer. The quantitative analysis of the scission products and the results of EA showed that hydrolysis, successive dehydration, and other various reactions changed the scission route to generate less f...
The previous decade has brought a remarkable increase of the interest in applications that deal with querying and mining of time series data. Many of the research efforts in this context have focused on introducing new representation methods for dimensionality reduction or novel similarity measures for the underlying data. In the vast majority of cases, each individual work introducing a particular method has made specific claims and, aside from the occasional theoretical justifications, provided quantitative experimental observations. However, for the most part, the comparative aspects of these experiments were too narrowly focused on demonstrating the benefits of the proposed methods over some of the previously introduced ones. In order to provide a comprehensive validation, we conducted an extensive experimental study re-implementing eight different time series representations and nine similarity measures and their variants, and testing ...
The nucleation of microdamage under dynamic loading was investigated through planar impact experiments accomplished with a light gas gun. The microscopic observation of recovered and sectioned specimens showed that microcracks were nucleated only by cracking of brittle particles inside material. However, for comparison the in situ static tensile tests on the same material conducted with a scanning electron microscope showed that the microcracks were nucleated by many forms those were fracture of ductile matrix, debonding particles from matrix and cracking of brittle particles. The quantitative metallographic observations of the specimens subjected to impact loading showed that most of the cracked particles were situated on grain boundaries of the aluminum matrix. These facts suggested the concept of critical size and incubation time of submicroscopic cavities in the dynamic case and the mechanism of embryo-damage induced nucleation by fracture ...
Quantitative Real-Time PCR (qRT-PCR) is a widely used tool to study host responses against parasites. A crucial step in the gene quantification process is the normalization of the expression data against stable housekeeping genes (HKGs). However, in recent years, several reports have showed that the transcriptional levels of such HKGs can change dramatically, especially when cellular changes appear in the tissues investigated. The aim of the current study was to assess the variability of 11 putative HKGs in bovine abomasal tissue during an infection with the parasitic nematode Ostertagia ostertagi. Gene transcription levels of selected potential HKGs were measured by qRT-PCR and the expression stabilities evaluated using geNorm, NormFinder, and The Mann-Whitney-U test. The analysis showed ...
Osteoporosis is accompanied by predominantly metaphyseal fractures with a delayed and qualitatively reduced healing process. This study addressed the question of whether fracture healing in the context of osteoporosis prophylaxis is improved with estrogen (E) or alendronate (ALN). Thirty-six ovariectomized and 12 sham-operated 12-week-old rats received soy-free (osteoporotic C, sham), E-, or ALN- supplemented diets. After 10?weeks, a metaphyseal tibia osteotomy and standardized T-plate fixation were performed. After a 5-week healing process, the fracture callus was evaluated qualitatively by biomechanical bending test and quantitatively in microradiographic sections. The time course of callus formation was examined using fluorochrome-labeled histological sections. Administration of E impro...
Abstract The healing of predominantly metaphyseal fractures in postmenopausal osteoporosis is delayed and comparatively poor. Due to the potential side effects of HRT, natural alternatives are appealing. The aim of this study was to determine whether Cimicifuga racemosa extract BNO 1055 improves metaphyseal fracture healing in severe osteopenic bone in rats. Thirty three 12 week old female rats developed severe osteopenia during 10 weeks after ovariectomy. After metaphyseal tibial osteotomy and standardized T plate osteosynthesis, the healing periods in ovariectomized rats (C), 17 estradiol (E) and Cimicifuga racemosa (CR) supplemented diets were assessed for 35 days. Changes in callus morphology were evaluated qualitatively by biomechanical testing and quantitatively in microradiographies...
The evaluation of biological markers is recognized as necessary to the future of toxicology, epidemiology, and quantitative risk assessment. For biological markers to become widely accepted, their validity...Full Text Available
Quantitative microscopy has been extensively used in biomedical research and has provided significant insights into structure and dynamics at the cell and tissue level. The entire procedure...Full Text Available
The convolution/superposition algorithm for computing dose from photon beams in radiation therapy planning requires knowledge of the energy spectrum. The algorithm can compute the dose for a polyenergetic beam as the weighted sum of the individual dose contributions from monoenergetic beams. In this study we exploit interface effects apparent in the dose distributions to discriminate among spectra of high energy photon beams. We have studied the sensitivity of the depth dose distribution to the energy components using a hypothetical beam for various field sizes and depths in water and water-lung-water media. Six theoretical spectra were simulated. We compared depth dose data from these spectra using three quantitative measures which are inherently free of normalization ambiguities: for homogeneous water, the ratio D_2_0/D_1_0 and a logarithmic derivative in the buildup region LD_b_u_i_l_d_-_u_p and for inhomogeneous lung/water, the lung correction factor (CF). It ...
We propose to investigate the spontaneous emission of radiation arising out of the interaction of a relativistic electron beam with a metallic grating (the Smith-Purcell effect). The work will concentrate, primarily, in the 50-120 #mu#m part of the infrared spectrum and will be an extension of the work begun by the Oxford-Dartmouth-Essex collaboration; one of the early objectives of the project will be to develop a quantitative understanding of the power spectrum of the emitted radiation over a wide range of emission angles. In particular, the limits of relativistic peaking of forward directed emission will be investigated. The electron beam will be produced by laser irradiation of a metallic cathode in the terminal of a small Van de Graff accelerator located in the Technische Universitaet, Muenchen. Beam energies will be in the range of 2 - 4 MeV. Initial tests on photoproduction of electrons have yielded 10 mA pulses with a width of about 20 ...
Biodiesel made from vegetable oil is among the most desirable of renewable energy sources because it can be a substitute for diesel oil. However, biodiesel from soybean or corn can be confronted with a food crisis. Microalgae is a new biodiesel source which contains high oil lipids with a high growth rate, and which also offers value-added products from the residue, such as cosmetics, health functional food or pharmaceuticals. Microalgae are best cultivated in photo-bioreactors (PBRs) where light, nutrients, carbon dioxide and temperature can be controlled. Despite the current availability of PBRs, only a few can be practically used for mass production. Computational fluid dynamics (CFD) was used in this study to design an optimum bubble-column PBR for mass production of microalgae. Multi-phase models including bubble movement, meshes and time step independent tests were considered to develop the 3-dimensional CFD model. Particle Image Velocimetry (PIV) ...
In order to clarify the alkali-resistance of fibers to be utilized as reinforcing materials for concrete, such as glass fiber, Aramid fiber, and carbon fiber, accelerated aging tests in alkaline solution were conducted. In detail, the degree of degradation of the fracture strength and Young's modulus were investigated through static tensile strength tests after soaking in alkaline solution of these fibers and then the mechanism of degradation was examined by observation using a scanning electron microscope. The conclusion obtained was as follows. Glass fiber was easily degraded in the alkaline solution and the progress of degradation was simulated quantitatively by the method proposed in this paper, which was based on a diffusion theory. Both Aramid fiber and carbon fiber showed a significant alkali-resistance without degrading. The reaction of glass fiber with alkaline solution proceeded uniformly from the surface ...
When the foundations of the building are designed and worked, the prediction calculation of immediate settlement of the building exercised practically is to calculate assuming the earth is a linear elastic body, but the actual stress-strain relationship of the earth is nonlinear and rigidity of the earth becomes lower as strain (or stress) increases. Hence in order to grasp the actual settling behavior of the earth, it is necessary to elucidate the nonlinear relationship between stress and strain. In this article, a prediction method of building settlement is introduced which uses an analytical technique of the multi-layered earth by the linear elasticity theory and takes into consideration strain dependency of rigidity of the earth. Part of the conclusion is as follows which has been obtained by studying the settling behaviors observed in examples of vertical loading tests of the pile foundations and the elasto-plastic settlement analytical method of the pile ...
Surface structure analysis, i.e. metallographic analysis of component surfaces with the aid of replicas, is an established method of component monitoring and the only reliable non-destructive method for detecting and analyzing beginning creep damage in the form of creep pores. Creep pore development provides a basis for component condition analysis. It must be noted, however, that the modern martensitic 9-12 % Cr steels - like the established steels 10CrMo9-10 (P22) und X20CrMoV12-1 - have comparatively high creep fracture deformation rates in fatigue tests. This raises the question if these steels can be judged on the basis of data for established steels. The results so far suggest that even with low pore densities (single pores), a higher degree of damage and a shorter time until failure must be assumed. [German] Eine bewaehrte Methode der Bauteilueberwachung stellt die Oberflaechengefuegeuntersuchung, d. h. die metallografische Untersuchung ...
A system and a related method for non-destructive evaluation of the surface characteristics of a magnetic material. The sample is excited by an alternating magnetic field. The field frequency, amplitude and offset are controlled according to a predetermined protocol. The Barkhausen response of the sample is detected for the various fields and offsets and is analyzed. The system produces information relating to the frequency content, the amplitude content, the average or RMS energy content, as well as count rate information, for each of the Barkhausen responses at each of the excitation levels applied during the protocol. That information provides a contiguous body of data, heretofore unavailable, which can be analyzed to deduce information about the surface characteristics of the material at various depths below the surface.
The properties of individual radioactive particles present in a sample, such as a swipe, are more interesting than bulk properties of the sample. The present work focuses on instrumentation that provides position-sensitive spectral information non-destructively from the sample. The experimental part of the work was realized using a device called PANDA (Particles And Non-Destructive Analysis). The detector setup used in the study contains a broad-energy HPGe gamma-ray detector and a position-sensitive alpha detector. Both detectors are connected to a time-stamping event-mode data acquisition system. The method is shown to locate particles with sub-millimetre accuracy and distinguish the interesting particles from non-interesting ones. (author)
Radiation damage is considered to be the major problem that still prevents imaging an individual biological molecule for structural analysis. So far, all known mapping techniques using sufficient short wave-length radiation, be it X-rays or high energy electrons, circumvent this problem by averaging over many molecules. Averaging, however, leaves conformational details uncovered. Even the anticipated use of ultra-short but extremely bright X-ray bursts of a Free Electron Laser shall afford averaging over 10^6 molecules to arrive at atomic resolution. Here we present direct experimental evidence for non-destructive imaging of individual DNA molecules. In fact, we show that DNA withstands coherent low energy electron radiation with deBroglie wavelength in the Angstrom regime despite a vast dose of 10^8 electrons/nm^2 accumulated over more than one hour.
Many nondestructive beam position monitors are known. However, these devices can not be used for DC particle beam diagnostics. We investigated a method of beam diagnostics applicable for the operative control of DC high power e-beam inside closed waveguide. A design of the detector for determination of{open_quote} center of mass {close_quote} position of DC particle beam was developed. It was shown that the monitor can be used as a nondestructive method for the beam position control in resonators. Magnetic field of the particle beam outside a resonator is used. The detector consists of the steel yokes and magnetic field sensors. The sensors measure magnetic fluxes in the steel yokes fixed outside the resonator. When the particle beam changes its position, these magnetic fluxes also change. Beam displacement sensitivity of the monitor depends on the steel yoke dimensions. The detector sensitivity is equal to 1 Gauss/mm for the conditions ...
A systematic study of the effects of environmental factors on nylon 66 and Kevlar 29 strength degradation in parachute components is being conducted at Sandia National Laboratories. It includes: (1) accelerated aging studies in air, inert environments, humidity, ozone, and smog; (2) a 25-year surveillance program of parachutes in a variety of natural climatic environments; (3) moisture absorption as a function of humidity; (4) effects of surface coatings normally applied to parachutes; and (5) development of nondestructive evaluation techniques which can be used to map mechanical properties over the entire parachute surface. The accelerated aging and moisture absorption studies show that air, humidity, and smog contribute to degradation. Chemiluminescence, gas chromatographic pyrograms, and uv spectroscopy show promise as nondestructive evaluation techniques.
In January 1994, a 6.7 magnitude earthquake in southern California ruptured a pipeline releasing approximately 4,200 barrels of blended San Joaquin Valley crude oil. A smaller volume entered the Santa Clara River and flowed 25 km downstream to an emergency containment dam. Ruptured water mains and chlorinated discharges from a damaged sewage treatment plant also affected water quality in the river. Quantitative injury assessment studies were initiated within days of the spill and included water/sediment chemistry, benthic macroinvertebrate community analyses and aquatic toxicity tests. Water quality values for TPH, BTEX, and chlorine ranged from nondetectable to 78 mg/l (TPH), nondetectable to 5.4 microg/l (total BTEX constituents) and nondetectable to 600 microg/l (residual chlorine) within 72 hours of the spill. Ammonia concentrations ranged from nondetectable to 12.1 mg/l within 10 days of the spill. Hydrocarbon concentrations in sediments ...
A necessary condition for crevice corrosion is that a crevice former create a sufficiently tight, restricted geometry on the metal surface to support the development of critical crevice chemistry. Crevice corrosion is affected by the crevice geometry (tightness) and the properties of the crevice former. The objective of this study is to determine the effect of the crevice former material on the evolution of localized corrosion-damage. A standard crevice corrosion test method is modified by (a) the use of ceramic, metal or polymer materials as the crevice former and (b) the variation of size and shape of the crevice. This study focuses on the post initiation stage of crevice corrosion and addresses factors that may limit the initiation of localized corrosion and also slow or stop the continued propagation of corrosion. Controlled crevice corrosion tests are performed under aggressive, accelerated conditions on Ni-Cr-Mo alloy C-22 and other ...
The aim of this study was to evaluate the automated urine test strip analyzer Aution Max AX 4280 which uses strips able to measure 12 urinary parameters. For precision study, we considered glucose, protein, blood, leukocytes, nitrite, and pH and the four first were compared with usual methods: chemical measurement or microscopic examination. Reproducibility of the semi quantitative results was determined as the proportion of results falling into the same concentration range. Within-run reproducibility assessed using urine specimens were between 83% and 96%. Between day on quality controlled materials, it was higher (96%), and leukocytes were shared between two classes 250 and 500 cells/microL. For glucose and proteins, linearity was good and comparison with quantitative methods yielded high correlation. The false negative fraction was low and there was no false positive results. For blood, fraction of false positive was ...
Twenty-two landrace-derived inbred lines from the Spanish Barley Core Collection (SBCC) were found to display high levels of resistance to a panel of 27 isolates of the fungus Blumeria graminis that exhibit a wide variety of virulences. Among these lines, SBCC145 showed high overall resistance and a distinctive spectrum of resistance compared with the other lines. Against this background, the main goal of the present work was to investigate the genetic basis underlying such resistance using a doubled haploid population derived from a cross between SBCC145 and the elite spring cultivar Beatrix. The population was genotyped with the 1,536-SNP Illumina GoldenGate Oligonucleotide Pool Assay (Barley OPA-1 or BOPA1 for short), whereas phenotypic analysis was performed using two B. graminis isolates. A major quantitative trait locus (QTL) for resistance to both isolates was identified on the long arm of chromosome 6H (6HL) and accounted for ca. 60% of the phenotypic ...
The authors compared unenhanced and contrast-enhanced fast MRI and Computerized Tomography in the detection of liver metastases. Eleven patients with single or multiple hepatic lesions (42 in all) were submitted to V and magnetic resonance studies; T1- and T2- weighted TSE, T2-weighted TSE with fat suppression, unenhanced breath-hold TFE and early or delayed enhanced breath-hold TFE images were acquired with a 1.5 T superconductive magnet (Philips NT). The quantitative analysis of all magnetic resonance images was performed for contrast/noise ratio (CNR) and number of detected lesions; magnetic resonance and Computerized Tomography images were also compared qualitatively for lesion conspicuity, anatomical structure identification and artifacts. The results were compared with Student's test. Early enhanced breath-hold TFE was statistically superior to T1-weighted TSE (p = .0009), T2-weighted TSE (p = .01) and Computerized Tomography ( p = .0004) ...
We have recently introduced several important improvements in the measurement of distillation curves for complex fluids. This new method is a significant improvement over current approaches, with features including a composition-explicit data channel for each distillate fraction (for both qualitative and quantitative analysis), trace chemical analysis of each distillate fraction, and a corrosivity assessment of each distillate fraction. In the present contribution, we present the application of the advanced distillation curve method to a bio-derived crude oil prepared from swine manure. One motivation behind the work was to precisely measure the distillation curve of the oil derived from swine manure with our advanced distillation apparatus and compare the bio-derived oil to traditional petroleum crude oils. Then, the information content of the bio-derived oil distillation was extended further with the composition-explicit data channel: gas chromatography-mass ...
The project is devoted to the development of novel insoluble anodes for copper electrowinning and electrolytic manganese dioxide (EMD) production. The anodes are made of titanium-lead composite material produced by techniques of powder metallurgy, compaction of titanium powder, sintering and subsequent lead infiltration. The titanium-lead anode combines beneficial electrochemical behavior of a lead anode with high mechanical properties and corrosion resistance of a titanium anode. In the titanium-lead anode, the titanium stabilizes the lead, preventing it from spalling, and the lead sheathes the titanium, protecting it from passivation. Interconnections between manufacturing process, structure, composition and properties of the titanium-lead composite material were investigated. The material containing 20-30 vol.% of lead had optimal combination of mechanical and electrochemical properties. Optimal process parameters to manufacture the anodes were identified. Prototypes having ...
The radionuclide X-ray fluorescence and particle induced X-ray emission methods were used for rapid and nondestructive analysis of metallic glasses. The methods were compared for accuracy and precision with the atomic absorption method. Some results of the analyses of Fe_xNi_8_0_-_xB_2_0 materials are briefly reviewed. The distribution of elements along the width as well as the length and a qualitative analysis of the composition of material surfaces are considered. (author).
Radionuclide X-ray fluorescence and particle induced X-ray emission methods were used for a rapid and nondestructive analysis of metallic glasses. The methods are compared in accuracy and precision with the atomic absorption method. Some results of analyses of Fe_xNi_8_0_-_xB_2_0 materials are briefly reviewed. The distribution of elements along the width and length, and a qualitative analysis of the composition of material surfaces are considered. (author) 3 refs.
This Conference paper is for submission to the 7th International Conference on NDE in Relation to Structural Integrity for Nuclear and Pressurized Components, in Yokohama, Japan Specifically, this paper is being presented at this Conference on May 12-14, 2009.
This document contains 59 extended synopses of the presentations delivered at the conference during oral and poster sessions. The four oral sessions were devoted to: The role of nuclear forensics in combating illicit trafficking and nuclear terrorism; Current capabilities and past experiences; Analytical techniques; and Challenges and alternative approaches. Each of the synopses was indexed separately
This document provides data on aerosol concentrations in tank headspaces, total mass of aerosols in the tank headspace, and mass of aerosols sent to the exhauster during rotary mode core sampling from November 1994 through June 1999. A decontamination factor for the RMCS exhauster filter housing is calculated based upon operational data and non-destructive assay.
A program to modernize existing computer control and data analysis in a precision gamma-scanning system is described. This involves interfacing a new computer-based multichannel analyzer to existing equipment through a CAMAC system with an intelligent crate controller and writing software for scan control and data reduction. Both hardware and software requirements are discussed. 6 figures.
The influence of high temperature thermal ageing treatments on the development of intercrystalline creep damage in two variants of Alloy 800 has been investigated. Ageing up to 3000 h and creep testing were carried out at 800 and 900 C. The high temperature behaviour of the 800HT variant is discussed with reference to the effect of heat treatments on the microstructure. The metallographic methods by which the creep damage was quantitatively determined are described. The growth rate of intercrystalline microcracks was described using a statistical model and the dependence of crack growth rate on the thermal history for both 800HT and 800H was determined. The carbide precipitation and growth processes were determined as functions of the exposure temperature and duration. The results showed the three characteristic stages, precipitation, growth and coarsening (Ostwald ripening). The largest increase in the intergranular creep damage was found in ...
For quantitative acquisition of the influence of surface decarburizing phenomena on the failure of construction parts under cyclic stress different surface decarburization stages were generated in the steels 42CrMo4 and 100Cr6. After construction part-specific thermal treatment the generated states of residual stress were then determined and life span-oriented fatigue tests were conducted. The studies showed that already a small decarburization in martensitic material conditions of the steels 42CrMo4 and 100Cr6 led to a reduction of the alternating bending strength. The decrease of alternate strength can be associated with the micro-notch effects caused by the internal oxides formed by surface oxidation and/or the residual tension stress developed during the hardening in sub-surface sample areas. Decarburization degrees of more than 50% cause a noticeable decrease of surface stability, an increase of residual tension stresses close to the ...
We describe a stochastic inversion method for mapping subsurface regions where the electrical resistivity is changing. The technique combines prior information, electrical resistance data and forward models to produce subsurface resistivity models that are most consistent with all available data. Bayesian inference and a Metropolis simulation algorithm form the basis for this approach. Attractive features include its ability to: (1) provide quantitative measures of the uncertainty of a generated estimate and, (2) allow alternative model estimates to be identified, compared and ranked. Methods that monitor convergence and summarize important trends of the posterior distribution are introduced. Results from a physical model test and a field experiment were used to assess performance. The stochastic inversions presented provide useful estimates of the most probable location, shape, and volume of the changing region, and the most likely resistivity ...
The ultimate compressive strength and modulus of elasticity of femoral cortical bone from adult geese (Anser anser), were determined by sex and by quadrant by compressing small right circular cylinders which were 2.4 mm in height and 0.8 mm in diameter. The average ultimate compressive strength was 183 +/- 29 MPa. The average modulus of elasticity was 13.2 +/- 3.4 GPa. The bending strength and bending modulus of elasticity were determined by a three point bend test on rectangular prisms which had the approximate dimensions 0.75 mm X 0.75 mm X 25 mm. The average bending strength was 263 +/- 44 MPa while the average bending modulus was 19.6 +/- 3.1 GPa. The calcium content was determined by atomic absorption spectrophotometry and no correlation was found with the mechanical properties. The histology of the cortical bone was examined both quantitatively and qualitatively. A unique type of Haversian bone is described. Goose bone was found to be ...
This report describes the sampling and chemical analyses of smoke gas components for combustion performed in the SP Industry Calorimeter, where continuous measurements of oxygen, carbon dioxide and carbon monoxide are an integrated part of the Calorimeter system. On-line measurements of nitrogen oxides and total amounts of unburnt hydrocarbons were performed. Hydrogen cyanide, hydrogen chloride and ammonia in the smoke were sampled and absorbed in impinger bottles and subsequently analyzed using wet chemical techniques. An adsorbent sampling system was designed to allow the identification and quantitative analysis of individual organic compounds in the smoke. Gas chromatography was utilized with a mass spectrometric detector for the identification and a FID for quantification of the total amounts as well as individual components. A procedure for cleaning the smoke gas duct in between the combustion experiments was designed and found to be effective. The materials ...
Human beings are confronted with another grievous disaster - coal fire. The monitoring on underground coal bed combustion relied on drilling supervising in the past, but this method is not good. By taking the coal fire of Gulaben mine in Inner Mongolia Autonomous Region as an example, the monitoring methods of underground coal bed combustion were explored based on the hyperspectra and high-resolution remote sensing technology. By employing the OMIS imaging apparatus developed by Shanghai Institute of Technical Physics of Chinese Academy of Sciences, the airborne hyperspectral images and the characteristic spectra of different types were obtained and the temperature was measured synchronously on the ground. Then according to the correlation of DN value of the thermal infrared band and surface temperature, the image information was processed, the spectral features were analyzed, and the surface temperature retrieval model was built. Finally, by hyperspectral imagery radiation temperature ...
A comprehensive experimental program on pullout tests of steel fibers from cement based matrices is described. A specially designed single fiber pullout apparatus was used to provide a quantitative determination of interfacial properties that are relevant to toughening brittle materials through fiber reinforcement. The parameters investigated included a specially designed high strength cement based matrix called Densified Small Particles system (DSP), a conventional mortar matrix, fiber embedment length, and the fiber volume fraction. The mediums from which the fiber was pulled included a control mortar mix without fibers, a mortar mix with 3, and 6 percent fibers by volume. The results indicate that: (1) the dense DSP matrix has significantly improved interfacial properties as compared to the conventional mortar matrix. (2) Increasing the fiber embedment length and the fiber volume fraction in the cement matrix increase the peak pullout load ...
The decays of charmed mesons into two body nonleptonic final states are investigated. Weak interaction amplitudes of interest in these decays are extracted from lattice four-point correlation functions using a effective weak Hamiltonian including effects to order G{sub f} in the weak interactions yet containing effects to all orders in the strong interactions. The lattice calculation allows a quantitative examination of non-spectator processes in charm decays helping to elucidate the role of effects such as color coherence, final state interactions and the importance of the so called weak annihilation process. For D {yields} K{pi}, we find that the non-spectator weak annihilation diagram is not small, and we interpret this as evidence for large final state interactions. Moreover, there is indications of a resonance in the isospin {1/2} channel to which the weak annihilation process contributes exclusively. Findings from the lattice calculation are compared to ...
In this work trailing edge noise levels of a research aerofoil have been computed and compared to aeroacoustic measurements using two different approaches. On the other hand, aerodynamic and aeroacoustic calculations were performed with the full Navier-Stokes CFD code Fluent [Fluent Inc 2005 Fluent 6.2 Users Guide, Lebanon, NH, USA] on the basis of a steady RANS simulation. Aerodynamic characteristics were computed by the aid of various turbulence models. By the combined usage of implemented broadband noise source models, it was tried to isolate and determine the trailing edge noise level. Throughout this work two methods of different computational cost have been tested and quantitative and qualitative results obtained. On the one hand, the semi-empirical noise prediction tool NAFNoise [Moriarty P 2005 NAFNoise User's Guide. Golden, Colorado, July. http://wind.nrel.gov/designcodes/ simulators/NAFNoise] was used to directly predict trailing edge ...
Previous research utilizing the AcB/BcA recombinant congenic strains (RCS) of mice mapped provisional quantitative trait loci (QTLs) for the psychostimulant effects of nicotine to multiple regions on chromosomes 7, 11, 12, 14, 16, and 17. The current study was designed to confirm these QTLs in an A/J (A)??C57Bl/6J (B6) F2 cross and a panel of B6.A chromosome substitution strains (CSS). The panel of B6.A CSS consists of 21 strains, each carrying a different A/J chromosome on a B6 background. The A??B6 F2, CSS, A, and B6 mice were tested for sensitivity to the effects of nicotine on locomotor activity using a computerized open-field apparatus. In A??B6 F2 mice two QTLs were identified which confirm those previously observed in the AcB/BcA RCS. Significant differences in the expression of ...
In order to evaluate the effects of radioactivity on active vegetal substances, samples of Fennel (Foeniculum vulgare Miller., fructus), Guarana (Paulinia cupana, Kunth, semen), Gingko (gingko biloba, L., folium), and Kawa-Kawa (Piper methysticum G. Forst, rhizoma), were treated with scaling doses (0 to 25 KGy) of gamma radiation (Co{sup 60}). The 'blind test' methodology was used. The active substances from each sample were analysed by qualitative and quantitative methods after radiation. There were no significant differences seen between the control sample (0 KGy) and the irradiated samples. Microbe contamination was significantly reduced, about 10000 CFU/g, with the initial 5 KGy dose. It was concluded that gamma radiation can be used as an alternative procedure to reduce microbiologic contamination in medicinal plants. Before this procedure can be extended to other medicinal plants, more specific analytical methods are ...
Two different methods for streamlined life cycle assessment (LCA) are described: the MECO-method and SLCA. Both methods are tested on an already made case-study on cars fuelled with petrol or ethanol, and electric cars with electricity produced from hydro power or coal. The report also contains some background information on LCA and streamlined LCA, and a deschption of the case study used. The evaluation of the MECO and SLCA-methods are based on a comparison of the results from the case study as well as practical aspects. One conclusion is that the SLCA-method has some limitations. Among the limitations are that the whole life-cycle is not covered, it requires quite a lot of information and there is room for arbitrariness. It is not very flexible instead it difficult to develop further. We are therefore not recommending the SLCA-method. The MECO-method does in comparison show several attractive features. It is also interesting to note that the MECO-method produces ...
Target vessel materials used in spallation neutron source will be exposed to proton and neutron irradiation and mercury immersion environments. In order to evaluate the surface degradation of the vessel candidate materials due to such environment, the triple-ion beam irradiation taking the spallation reaction into account and mercury immersion tests were carried out. Mechanical properties of the gradient surface layer were evaluated by the inverse analysis with multi-layer model that considers distribution of surface characteristic was applied to the load and depth curves measured by using the instrumented indentation machine. Transmission electron microscopic observations were performed to evaluate the changes of microstructure in irradiated surface layer using focused ion-beam cut micro-specimen. The mechanical properties distributions in the surface layer were evaluated quantitatively and the changes in microstructures were correspondent to ...
A rapid extraction procedure has been developed for speciation of arsenic in chicken tissue. Water, methanol-water (1:1), and methanol-chloroform (1:1) were tested as extraction media. Individual use of an ultrasonic bath, a microwave oven, or an ultrasonic probe was not sufficient for quantitative recovery of As(III), dimethylarsinate, monomethylarsonate, As(V), and arsenobetaine in spiked samples of chicken tissue. A new extraction procedure using a methanol-water mixture and a microwave oven then an ultrasonic probe enabled extraction of the arsenic species in 7 min with efficiencies ranging from 80 to 100%. HPLC-UV-HG-AFS was used for the determinations. The extraction procedure was 100% efficient when applied to real samples of chicken tissue. AsB (48{+-}5 {mu}g As kg {sup -1}) and one containing-arsenic feed additive, Nitarsone (227{+-}5 {mu}g As kg {sup -1}) were detected. (orig.)
A quantitative transmission electron microscopy (TEM) study on the depth profile of extended defects, formed after Si implantation, has been carried out. Two different Si{sup +} implant conditions have been considered. TEM analysis for the highest energy/dose shows that {l_brace}1 1 3{r_brace} defects evolve into dislocation loops whilst the defect depth distribution remains unchanged as a function of annealing time. For the lowest energy/dose, {l_brace}1 1 3{r_brace} defects grow and dissolve while the defect band shrinks preferentially on the surface side. At the same time, extraction of boron transient enhanced diffusion (TED) as a function of depth shows a decrease of the supersaturation towards the surface, starting at the location of the defect band. The study clearly shows that in these systems the silicon surface is the principal sink for interstitials. The results provide a critical test of the ability of physical models to simulate ...
A quantitative transmission electron microscopy (TEM) study on the depth profile of extended defects, formed after Si implantation, has been carried out. Two different Si"+ implant conditions have been considered. TEM analysis for the highest energy/dose shows that #left brace#1 1 3#right brace# defects evolve into dislocation loops whilst the defect depth distribution remains unchanged as a function of annealing time. For the lowest energy/dose, #left brace#1 1 3#right brace# defects grow and dissolve while the defect band shrinks preferentially on the surface side. At the same time, extraction of boron transient enhanced diffusion (TED) as a function of depth shows a decrease of the supersaturation towards the surface, starting at the location of the defect band. The study clearly shows that in these systems the silicon surface is the principal sink for interstitials. The results provide a critical test of the ability of physical models to ...
We report on the contents and results for 360 students of a mathematics assessment administered at the start of the second-semester introductory chemistry course required for science and engineering majors at the University of Minnesota. This calculator-free, 20-question, 30-minute, multiple-choice, diagnostic quiz includes questions selected specifically for their relevance to this course, concerning logarithms, scientific notation, graphs, and algebra. For the 325 students in degree-granting programs, significant correlations are reported between their mathematics assessment scores and success in this course, as measured by performance on exams (for which scientific calculators were permitted) and course grades. These observations suggest that responses to the simple questions on this unannounced quiz have some predictive utility as signatures of underlying thinking and learning patterns that are associated with success in this course. In addition, we argue that these results ...
The present paper deals with the fouling process of calcium sulfate dehydrate on heat-transfer surfaces. The crystallization of calcium sulfate showed typical asymptotic fouling curves, the asymptotic value of which was greatly influenced by the surface temperature and fluid velocity. The fouling mechanism was discussed with a generalized fouling model and proved to be surface process controlled, where the activation energy was 6.2 {times} 10{sup 4} J/mol. The availability of mechanical cleaning against the formed scale was quantitatively evaluated by applying the particle abrasion method. The removal test verified that the removing rate per unit particle concentration decreased in an inverse proportion to the overall particle load, to the power of 0.8, and that it was affected by the fluid velocity. The observed final residual fouling resistance decreased asymptotically with an increase in particle concentration. The suitable concentration of ...
Molecular genetic markers can be used to identify quantitative trait loci (QTL) for thermal resistance and this has allowed characterization of a major QTL for knockdown resistance to high temperature in Drosophila melanogaster. The QTL showed trade-off associations with cold resistance under laboratory conditions. However, assays of thermal tolerance conducted in the laboratory may not necessarily reflect performance at varying temperatures in the field. Here we tested if lines with different genotypes in this QTL show different thermal performance under high and low temperatures in the field using a release recapture assay. We found that lines carrying the QTL genotype for high thermal tolerance were significantly better at locating resources in the field releases under hot temperatures while the QTL line carrying the contrasting genotype were superior at cold temperatures. Further, we studied copulatory success between the different QTL ...
Liquid high-level nuclear waste will be immobilized at the Savannah River Site (SRS) by vitrification in borosilicate glass. The glass will be produced and poured into stainless steel canisters in the Defense Waste Processing Facility (DWPF). Eventually these canistered waste forms will be sent to a geologic repository for final disposal. In order to assure acceptability by the repository, the Department of Energy has defined requirements which DWPF canistered waste forms must meet. These requirements are the Waste Acceptance Preliminary Specifications (WAPS). The WAPS require DWPF to identify the crystalline phases expected to be present in the final glass product. Knowledge of the thermal history of the borosilicate glass during filling and cooldown of the canister is necessary to determine the amount and type of crystalline phases present in the final glass product. Glass samples of seven projected DWPF compositions were cooled following the same temperature profile as that of glass ...
Background The objective of this study was to confirm provisional quantitative trait loci (QTL) for cocaine-induced locomotor activation, on chromosomes 1, 5, 6, 9, 12, 15, 16, 17, and 18, previously identified in the AXB/BXA recombinant inbred (RI) and AcB/BcA recombinant congenic (RC) strains of mice derived from A/J (A) and C57BL/6J (B6) progenitors. This was accomplished through a genetic analysis of cocaine-induced activity in an AxB6 F2 cross and a phenotypic survey across a panel of B6.A chromosome substitution strains (CSS) mice. Mice were tested for cocaine-induced activity, following administration of saline and cocaine (20?mg/kg), utilizing an open-field procedure. Results Among AxB6 F2 mice, differences in cocaine-induced activity were associated with loci on chromosome 1 (D1Mi...
OBJECTIVETo assess the new quantitative bone scan parameters as markers of Charcot neuroosteoarthropathy (CNO) activity.RESEARCH DESIGN AND METHODSForty-two...Full Text Available
Emphasis was put on the comparative quantitative structure-activity approaches to the exploration of action mechanisms of structurally different classes of compounds showing the same type of activity...Full Text Available
Effective small interfering RNA (siRNA)–mediated therapeutics require the siRNA to be delivered into the cellular RNA-induced silencing complex (RISC). Quantitative information of this essential...Full Text Available
Gene expression data has been used in lieu of phenotype in both classical and quantitative genetic settings. These two disciplines have separate approaches to measuring and interpreting epistasis, which...Full Text Available
Deficits in prepulse inhibition (PPI) are a biological marker for schizophrenia. To unravel the mechanisms that control PPI, we performed quantitative trait loci (QTL) analysis on 1,010 F2 mice derived...Full Text Available
The Electronic REference To access In vivo Concentrations (ERETIC) method was applied to 1H HR-MAS spectroscopy. The accuracy, precision, and stability of ERETIC as a quantitative...Full Text Available
The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.
In Japan, the development of next-generation Light Water Reactor has been launched since April 2008. The development program will be completed in 2015. The purpose of development is to cope with the replacement for existing nuclear power plants after 2030 in Japan and the expanding demand for nuclear power in the world; 'Nuclear Renaissance.' The reactor also aims to be global standard at around 2030. The requirements for global standard and domestic users have been investigated through the feasibility study of past 2 years, 2006-2007, and six innovative features or 'Core-Concepts' were established as follows. A) Reactor core system with uranium enrichment above 5% for significant decrease of spent fuel discharge and prominent higher availability B) Long-life materials and innovative water chemistry technologies for 80 years plant lifetime and significant reduction of occupational dose C) Seismic isolation technologies to standardize plant design independent from site conditions D) ...
A simple and specific method has been developed for the simultaneous determination of the four major Cinchona alkaloids and their dihydroderivatives and pyridoxine hydrochloride (Vitamin B_6) by high-performance liquid chromatography (HPLC) with fluorescence detection (#lambda#_e_m=420 nm with #lambda#_e_x=330 nm). The chromatographic separation was performed on a Phenomenex Prodigy ODS column (5 #mu#m, 250 mmx3.2 mm i.d.), recommended for basic compounds, under isocratic reversed-phase conditions. The method allowed a good peak shape and an effective resolution of the tested compounds. The extraction of alkaloids from the Cinchona succirubra bark was carried out in mild and fast conditions (ambient temperature, 20 min) by ultrasonication. The procedure showed to be advantageous respect to a reference method, which involved Soxhlet extraction. The results were compared statistically by means of the Student's t-test and the variance ratio ...
This report forms part of an independent review of the specifications, execution and results of Task 6 of the Aespoe Task Force on Modelling of Groundwater Flow and Transport of Solutes, which is seeking to provide a bridge between site characterization (SC) and performance assessment (PA) approaches to solute transport in fractured rock. The present report is concerned solely with Task 6C, which relates to the construction and parametrisation of a block-scale hydrostructural model of the TRUE Block Scale region of the Aespoe Hard Rock laboratory. The task objectives, specifications and outcome are summarised and reviewed. Also, consideration is given to how the hydrostructural model might affect the outcomes of Task 6D and 6E. The main conclusions of this review are summarised below: The Task 6C hydrostructural model is a more comprehensive approach to quantitatively describing a volume of fractured rock than has been achieved hitherto. The idea of including ...
The development and improvement of materials plays a key role in energy technology, particularly in power plant technology, because materials are crucial to plant performance and power availability. This becomes particularly clear when one considers that modern power plants generate temperatures of up to 600 C and pressures of up to 230 bar in order to increase process efficiency, conserve resources and reduce CO{sub 2} emissions. Modern heat-resistant materials for power plant technology are customised materials which have been developed to meet the specific requirements of special applications. After the requirement profile has been determined the material is developed or optimised on the basis of previous experiences gained with materials in power plant technology. Basic heat-resistant materials are ferritic materials containing 9 to 12% Cr as well as additions of Mo, V, Nb and W, amongst other elements. Together with the thermomechanical processing, the last-named elements play an ...
Purpose/Objective: At present, treatment verification between portal and reference images is performed based on manually-identified features by radiation oncologist, which is both time-consuming and potentially error-prone. There is a demand for the computerized verification procedure in clinical application. The purpose of this study is to develop a computerized portal verification scheme for pelvic treatment fields. Materials/Methods: The automated verification system involves image acquisition, image feature extraction, feature matching between reference and portal images and quantitative evaluation of patient setup. Electronic portal images with a matrix size of 256 x 256 and 12 bit gray levels were acquired using a liquid matrix electronic portal imaging device. Simulation images were acquired by digitizing simulation films using a TV camera into images with 256 x 256 matrix and 8 bit gray levels. Initially a Canny edge detector is applied to identify the ...
CT is the most accurate method to detect pulmonary emphysema in vivo. They compared prospectively two different methods for emphysema quantitation in 5 normal volunteers and 20 consecutive patients with chronic obstructive pulmonary disease (COPD). All subjects were submitted to function tests and HRCT; three scans were acquired at preselected levels during inspiration. The type and extent of pulmonary emphysema were defined by two independent observers under blind conditions. Disagreements were subsequently settled by consent. All subjects were also examined with expiratory spiral CT using a density mask program, at two different cut-off levels (-850,-900 HU). Visual score and expiratory spiral density mask values (-850 HU) were significantly correlated (r = 0.86), but the visual extent of emphysema was always higher than shown by expiratory spiral CT. The emphysema extent assessed with both CT methods correlated with the function result of ...
CT is the most accurate method to detect pulmonary emphysema in vivo. They compared prospectively two different methods for emphysema quantitation in 5 normal volunteers and 20 consecutive patients with chronic obstructive pulmonary disease (COPD). All subjects were submitted to function tests and HRCT; three scans were acquired at preselected levels during inspiration. The type and extent of pulmonary emphysema were defined by two independent observers under blind conditions. Disagreements were subsequently settled by consent. All subjects were also examined with expiratory spiral CT using a density mask program, at two different cut-off levels (-850,-900 HU). Visual score and expiratory spiral density mask values (-850 HU) were significantly correlated (r = 0.86), but the visual extent of emphysema was always higher than shown by expiratory spiral CT. The emphysema extent assessed with both CT methods correlated with the function result of ...
Swimming endurance of whiteleg shrimp, Litopenaeus vannamei exposed to various temperatures (15, 20, and 25 degrees C) and salinities (15, 32, and 40 per thousand) was determined in a swimming channel against one of five flow velocities (5.41, 6.78, 8.21, 10.11, and 11.47 cm s(-1)) for up to 9000 s. No shrimp swam the full 9000 s throughout the experiment. The swimming endurance decreased as swimming speed was increased at any of the temperatures and salinities tested and was significantly affected by temperature and salinity (Ppower model (nu x t(b) = a) showed a better fit to the relationship between swimming endurance (t, in s) and swimming speed (nu, in cm s(-1)) at any of the temperatures and salinities tested. The swimming ability index (SAI), defined as SAI = integral(0)(9000) vdt x 10(-4) (cm), was found to be temperature- and salinity-dependent in L. vannamei. The optimum temperature and salinity and corresponding maximum SAI were Topt ...
To achieve sufficient thermodynamic efficiency, space nuclear power systems must operate above 1000"0C. A quantitative evaluation of the existing mechanical properties data for the refractory alloys relevant to space nuclear power systems design lifetimes up to seven years at temperatures up to 1400"0C is being conducted. The most important properties for space nuclear power systems are long-term high-temperature (>1000"0C) creep strength and ductility, low-temperature (<400"0C) fracture toughness [including ductile-to-brittle transition temperature, (DBTT)], and ductility at high strain rates; of special concern are the above properties for weldments of refractory alloys, composition, applied stress, test temperature, test environment (e.g., vacuum, lithium), and thermomechanical treatment (TMT) history. Currently being evaluated are, in order of ascending mp, selected alloys of niobium (e.g., Nb-1% Zr, Nb-1% Zr-0.1% ...
To achieve sufficient thermodynamic efficiency, space nuclear power systems must operate above 1000/sup 0/C. A quantitative evaluation of the existing mechanical properties data for the refractory alloys relevant to space nuclear power systems design lifetimes up to seven years at temperatures up to 1400/sup 0/C is being conducted. The most important properties for space nuclear power systems are long-term high-temperature (>1000/sup 0/C) creep strength and ductility, low-temperature (<400/sup 0/C) fracture toughness (including ductile-to-brittle transition temperature, (DBTT)), and ductility at high strain rates; of special concern are the above properties for weldments of refractory alloys, composition, applied stress, test temperature, test environment (e.g., vacuum, lithium), and thermomechanical treatment (TMT) history. Currently being evaluated are, in order of ascending mp, selected alloys of niobium (e.g., ...
Martin Marietta Energy Systems, Inc. (Energy Systems) manages a closed hazardous waste disposal unit, Chestnut Ridge Security Pits (CRSP), in the form of two trenches and several auger-holes, located on top of the eastern portion of Chestnut Ridge at the Department of Energy (DOE) Oak Ridge Y-12 Plant in Tennessee. The groundwater monitoring system for the unit presently consists of a network of upgradient and downgradient monitor wells. To investigate the discharge of groundwater to springs and streams. An initial dye-tracer study was conducted during the driest part of 1990. The dye was detected at some of the monitoring sites, but verification was necessary due to the proximity of some sites to extraneous dye sources. A second dye-tracer was conducted during the wet weather season. The actual test commenced during the first week of February 1992 with a 4-week baseline monitoring period to determine the inherent variability of the emission spectra within the ...
The Soldier Information Requirements Technology Demonstration (SIREQ TD) project is an experimentation program to identify technologies that significantly enhance the performance of our future soldiers. One of the study series involved a 2 x 2 factorial comparison of the benefits of digital maps over paper maps, and the use of radios vs. no radios. Thirty-two Canadian regular force infantry soldiers performed force-on-force tactical assault missions in wooded terrain, with each soldier participating in all four test conditions. The radios were configured to operate in 4 subnets: 1 channel for each of the 2 Assault Groups (4 soldiers on a channel); a Section Commander/2IC channel; and an all-users channel. Note that in the no-radio conditions soldiers still operated the press-to-talk switch to allow recording of communications, but the speaker volume was set to zero. All communications were date/time stamped, identified as to the user and channel, and the audio was ...
Purpose: To evaluate micro computed tomography (micro-CT) for the assessment of osteochondritis dissecans in comparison with histology. Material and Methods: Osteochondritis dissecans lesions of 3 patients were evaluated using micro-CT (0.125 mA, 40 keV, 60 m slice thickness, 60 m isotropic resolution, entire sample) and light microscopy (toluidine blue, 3-5 m slice thickness). The methods were compared regarding preparation time, detectability of tissue types and morphologic features of bone and cartilage. Results: Non-destructive micro-CT imaging of the entire sample was faster than histologic preparation of a single slice for light microscopy. Morphologic features of bone and cartilage could be imaged in a comparable way to histology. It was not possible to image cells or different tissue types of bone and cartilage with micro-CT. Conclusion: Micro-CT is a fast, non-destructive tool that may be a supplement or, if detailed histologic ...
Purpose: To evaluate micro computed tomography (micro-CT) for the assessment of osteochondritis dissecans in comparison with histology. Material and Methods: Osteochondritis dissecans lesions of 3 patients were evaluated using micro-CT (0.125 mA, 40 keV, 60 m slice thickness, 60 m isotropic resolution, entire sample) and light microscopy (toluidine blue, 3-5 m slice thickness). The methods were compared regarding preparation time, detectability of tissue types and morphologic features of bone and cartilage. Results: Non-destructive micro-CT imaging of the entire sample was faster than histologic preparation of a single slice for light microscopy. Morphologic features of bone and cartilage could be imaged in a comparable way to histology. It was not possible to image cells or different tissue types of bone and cartilage with micro-CT. Conclusion: Micro-CT is a fast, non-destructive tool that may be a supplement or, if detailed histologic ...
The electromagnetic properties that present hydrogen and other nucleus of agro-alimentary products, have allowed widely use of magnetic resonance (MR) to study the composition and internal structure of these biological materials in a micro and macroscopic scale, in a nondestructive way. In this paper the physical principles, basic equipment to measure the MR signals and the MR imaging of any biological sample, are explained. It is also shown a review of the main agro-alimentary applications, emphasizing in the use of this principle to examine the internal quality of fruits and vegetables. In these products, the MR has been used to detect and follow the evolution of different factors that determine the internal quality after harvesting, during storage and after post harvesting processes. The main studies that have been conducted with MR in harvested products are about physiological disorders that take place during storage and conservation of fruits in controlled and ...
Summaries are presented for those research contracts which expired between December 31, 1960 and December 31, 1981. Topics covered include: factors controlling distribution of fission products in biosphere, non-destructive methods of evaluating the U/sup 235/ and Pu content of irradiated fuel elements, studies of contamination in local marine resources, tracer studies of anemia, non-destructive analysis of irradiated fuel elements using a flux integrating monitor, mechanism of proteolysis of I/sup 131/-labeled fibrinogen, radiosensitivity of spermatogonia of Drosophila melel elements by gamma scanning, uptake and loss of radioactive material by marine bacteria, factors which influence the movement of radioactive strontium from soils to plants, biological concentration of fission products in mollusks from water, decay scheme of Tl/sup 210/, calcium balance in metabolic bone disease, development of radioactive drugs ...
The following are reported: colorimetric determination of Ti in Cr, decontamination of metals by anodic dissolution, computer code for x-ray peak identification, gel-permeation chromatography of CoRezyn 1664 polyester resin, infrared monitoring of gases and vapors, particle size analysis of dusts, nondestructive analysis of Oralloy for removable alpha contamination, dissolution (digestion) of high-fired oxides, assay of U in a Pu-U alloy, measurement of oxide thickness on Pu metal by x-ray diffraction, analysis of precipitated Pu peroxide, differentiation of Dowex SBR and 11 resins, and determination of Pu solubility in simulated lung fluid.
Original investigations of ablation of minerals, fullerene-like compounds, polymers and complicated biological macromolecules under the action of submillimeter radiation of the free-electron laser (FEL) developed and built at Budker Institute of Nuclear Physics [V.P. Bolotin et al., First experiments on high-power Novosibirsk terahertz free-electron laser, Budker INP, 2005, p. 37 [1
Direct determination of "2"3"2U and its decay products in animal tissues appears to be feasible using an intrinsic Ge(Li) diode detector (for energies of 5-100 keV) and a NaI(Tl) anticoincidence-shielded Ge(Li) diode for higher-energy gamma photons. The detection sensitivity for "2"3"2U and "2"2"8Th is 0.03 and 0.01 nCi, respectively, using a 300-min counting time.
ObjectivesObjectives Not AvailableDescriptionTo determine the effects of water penetration on the burst strength of filament wound composite pipes which have been damaged by impact and then subjected to long term pressurisation with sea water. ~%~ To monitor and characterise the damage and effects of sea water penetration using ultrasonic NDT. To determine the burst strength of bonded composite pipe joints with and without defects and to see whether the defects can be detected using ultrasonic NDT. [continued...
AFFF has fabricated the (U, Pu)O_2 mixed oxide fuels for PHWRs, BWRs, PFBRs and FBTRs. The quantitative dissolution of the fuel samples are required within time for accurate determination of uranium-plutonium in chemical quality control laboratory. This paper describes the use of microwave heating technique in quantitative dissolution of (U, Pu)O_2 MOX (from 0.4% to 44% PuO_2). (author)
Magnetite nanoparticles with high self-heating capacity and low toxicity characteristics are a promising candidate for cancer hyperthermia treatment. In order to achieve minimum dosage to a patient, magnetic nanoparticles with high heating capacity are needed. In addition, the influence of physiological factors on the heat capacity of a material should be investigated in order to determine the feasibility. In this study, magnetite nanoparticles coated with lauric acid were prepared by co-precipitation of Fe{sup 3+}:Fe{sup 2+} in a ratio of 2:1, 5:3, 3:2, and 4:3, and the pH was controlled using NaOH. Structural and magnetization characterization by means of X-ray diffractometry (XRD) and a superconducting quantum interference device (SQUID) revealed that the main species was Fe{sub 3}O{sub 4} and further showed that most of the nanoparticles exhibited superparamagnetic properties. All of the magnetic nanoparticles showed a specific absorption rate (SAR) increase that was linear with ...
Automatic segmentation of anatomical structures in medical images is a valuable tool for efficient computer-aided radiotherapy and surgery planning and an enabling technology for dynamic adaptive radiotherapy. This paper presents the design, algorithms and validation of new software for the automatic segmentation of CT images used for radiotherapy treatment planning. A coarse to fine approach is followed that consists of presegmentation, anatomic orientation and structure segmentation. No user input or a priori information about the image content is required. In presegmentation, the body outline, the bones and lung equivalent tissue are detected. Anatomic orientation recognizes the patient's position, orientation and gender and creates an elastic mapping of the slice positions to a reference scale. Structure segmentation is divided into localization, outlining and refinement, performed by procedures with implicit anatomic knowledge using standard image processing operations. ...
... These assumptions are quantitatively investigated by calculating tie icldti\\e inportance of ... A modified lon-shore current model is used to study the ...
BackgroundDiscrepancies between the conclusions of different meta-analyses (quantitative syntheses of systematic reviews) are often ascribed to methodological differences. The objective...Full Text Available
A specific application of single photon emission tomography to the relative quantitation of the pituitary region is described together with the results obtained in 19 patients with pituitary adenoma...Full Text Available
Motivation: Automatic recognition of cell identities is critical for quantitative measurement, targeting and manipulation of cells of model animals at single-cell resolution. It has been...Full Text Available
Typing Workshop": [Introductions] [Intro, DNA Basics, and Historical Perspective] [DNA Extraction] [Validation and QA/QC] [DNA Quantitation] [PCR Amplification] [STR Loci and Kits]...
BACKGROUND: An approach to the study of the pharmacokinetics of drugs in the lung is to measure their concentrations in bronchial biopsy specimens. The main criticism of this technique is that bronchial...Full Text Available
This laboratory exercise demonstrates some basic principles in parasitology by using experimental studies of the relationship of Hymenolepis diminuta with its rodent host.
Abstract: The current financial crisis has now led most major central banks to rely on quantitative easing. The unique Japanese experience of quantitative easing is the only experience which enables us to judge this therapy's effectiveness and the timing of the exit strategy. In this paper, we provide a new empirical framework to examine the effectiveness of Japanese monetary policy during the ''lost'' decade and quantify the effect of quantitative easing on Japan's activity and prices. We combine advantages of Markov-switching VAR methodology with those of factor analysis to establish two major findings. First, we show that the decisive change in regime occurred in two steps: it crept out from late 1995 and established itself durably in February 1999. Second, we show for the first time th...
Absolute measurements of cerebral blood flow (CBF) are an important endpoint in studies of cerebral pathophysiology. Currently no accepted method exists for in vivo longitudinal...Full Text Available
... and high-quality photospheric-phase Type II SN spectra to constrain core- collapse SN explosions, massive star evolution, and distances in the Universe ...
OBJECTIVEEvaluate the qualitative and quantitative differences between moderated and unmoderated on-line social support groups focused on asthma.DESIGNA...Full Text Available
Computer-Aided Prediction of Chemical Ecotoxicity on the basis of Quantitative Structure-Activity Relationships with the Use of Physico-Chemical Descriptors, Including H-bond Parameters
AIM: To investigate the effects of gallbladder stones on motor functions of the gallbladder and the dynamics of bile flow in asymptomatic gallstone disease.METHODS: Quantitative hepatobiliary...Full Text Available
OBJECTIVE AND DESIGNThis study used qualitative and quantitative methods to examine the reasons primary care physicians and nurses offered for their inability to initiate guideline-concordant...Full Text Available
The concentration of apolipoproteins was measured by quantitative immunoelectrophoresis in rat serum, in the lipoprotein-free ultracentrifugal fraction (density greater than 1.21) of serum, and in renal...Full Text Available
In this model, without dark matter, the flat rotation curves of galaxies and the mass-to-light ratios of clusters of galaxies are described quantitatively. The hypothesis is that the agent of gravitational...Full Text Available
On-orbit spectral calibration of hyperspectral imaging data is a key step for quantitatively analyzing them. Like the atmospheric correction, accurate spectral calibration is very necessary for improved studies of land or ocean surface properties. Based on the previous literatures, a new method which coupled an optimization algorithm was developed to simultaneously retrieve the central wavelength and the full width at half maximum (FWHM) of the hyperspectral sensor without needing the in situ reflectance spectra. Firstly, the Hyperion data set simulated using MODTRAN4 with the Hyperion spectral specification was used to test the new method, and the results indicated that the maximum error was less than 0.1 and 0.7 nm for central wavelength and FWHM respectively when the spectral shift is 5 nm. Then the algorithm was applied to the Hyperion data acquired on May 20, 2008 over Heihe River Basin and it was iteratively performed for each detector of ...
The primary objectives of this study were to test two utility analysis models, the Cascio-Ramos Estimate of Performance in Dollars (CREPID) model and Godkewitsch financial utility analysis model and to determine their appropriateness as tools for evaluating training. This study was conducted in conjunction with Philadelphia Electric Company's Nuclear Training Group. Job performance of nuclear maintenance workers was assessed to document the impact of the training program. Assessment of job performance covered six job performance themes. Additionally, front-line nuclear maintenance supervisors were interviewed to determine their perceptions of the nuclear maintenance training. A comparison of supervisor's perceptions and outcomes of the utility analysis models was made to determine the appropriateness of utility analysis as quantitative tools for evaluating the nuclear maintenance training program. Application of the CREPID ...
Three copper-based alloys, CDA 102 (oxygen-free, high-purity copper), CDA 613 (aluminum bronze), and CDA 715 (Cu-30Ni), are candidates for the fabrication of high-level radioactive-waste disposal containers. Waste will include spent fuel assemblies from reactors as well as borosilicate glass, and will be sent to the prospective repository site at Yucca Mountain in Nye County, Nevada. The decay of radionuclides will result in the generation of substantial heat and in fluxes of gamma radiation outside the containers. In this environment, container materials might degrade by atmospheric oxidation, general aqueous phase corrosion, localized corrosion (LC), and stress corrosion cracking (SCC). This volume is a critical survey of available data on pitting and crevice corrosion of the copper-based candidates. Pitting and crevice corrosion are two of the most common forms of LC of these materials. Data on the SCC of these alloys is surveyed in Volume 4. Pitting usually occurs in water that ...
As part of the Wisconsin road weather safety initiative, the objective of this study is to assess the effects of rainfall on the severity of single-vehicle crashes on Wisconsin interstate highways utilizing polychotomous response models. Weather-related factors considered in this study include estimated rainfall intensity for 15 min prior to a crash occurrence, water film depth, temperature, wind speed/direction, stopping sight distance and deficiency of car-following distance at the crash moment. For locations with unknown weather information, data were interpolated using the inverse squared distance method. Non-weather factors such as road geometrics, traffic conditions, collision types, vehicle types, and driver and temporal attributes were also considered. Two types of polychotomous response models were compared: ordinal logistic and sequential logistic regressions. The sequential logistic regression was tested with forward and backward formats. Comparative ...
Objectives: To minimize movement artifacts during tracer imaging studies, the animals are generally sedated. Although many reports describe the effect of barbiturates on brain function, less is published about the general impact on the extracerebral metabolism and tracer biodistribution. This report describes the influence of pentobarbital on tumor uptake of ["1"2"3I]-2-iodo-L-phenylalanine (["1"2"3I]-2I-L-PA) using dissection and nuclear imaging. Methods: R1M tumor-bearing athymic mice were divided into two populations: untreated and pentobarbital-treated. Each group was subjected to dynamic and static planar imaging and organ dissection after ["1"2"3I]-2I-L-PA injection. Two-compartment blood modeling was performed. Analysis of variance (ANOVA), t test and clustered boxplot analyses were used to compare the results between the treatment groups and between the data acquisition methods. Results: Two-compartment blood modeling demonstrated that pentobarbital ...
Nitric acid leaching from the weak base anion (WBA) exchanger had been evaluated and based on this a 5% mixture of nitric acid loaded weak base anion exchanger with fresh weak base anion exchanger (NLWBA) at the bottom of the ion exchange column has been devised to maintain an outlet pH in the range of 5.0 to 5.5 during Gd removal from the moderator system of TAPP - 3 and 4. A three layered bed had been constituted wherein strong acid cation (SAC) exchanger is placed as the top layer while a mixed bed of SAC and WBA or pure WBA is used as the middle layer and the 5% NLWBA was used as the bottom most layer. This bed configuration would result in an iso-pH regime in the moderator system during the Gd removal along with quantitative removal of Gd. Two three-layer bed columns were prepared at TAPS - 3 and 4 in July 07. The resin was loaded in batches and after preparing the column, the column was deuterated with heavy water (> 99.75 % w/w) at a steady flow rate of ...
With an objective to know coal condensation structure which has influence on coal conversion reaction, an attempt was made on quantitative evaluation of hydrogen bonding in coal. Using as test samples the VDC made from Taiheiyo coal swollen by tetralin and vacuum-dried, and its pyrolyzed char, DSC measurement and Fourier transform infrared spectroscopy (FT) were performed. An FT spectrum comparison revealed that the VDC swollen at 220{degree}C has the hydrogen bonding relaxed partly from the original coal. However, since the change is in a huge coal molecular structure restraining space, it has stopped at relaxation of the bonding energy without causing separation as far as free radicals. On the other hand, the DSC curve shows that the VDC has slower endothermic velocity than the original coal. In other words, the difference in heat absorption amounts in both materials is equivalent to the difference of enthalpy ({Delta} H) of both materials, ...
Ground source heat pumps (GSHPs), often referred to as geothermal heat pumps (GHPs), offer an attractive option for heating and cooling residential and commercial buildings owing to their higher energy efficiency compared with conventional systems. GSHPs have been used for four years in the Turkish market, although they have been in use for more years in developed countries. The purpose of this study is to present an energy and exergy analysis of a GSHP system with a 50 m vertical 1.25 in. nominal diameter U-bend ground heat exchanger. This system was applied to a 65 m"2 room in the Solar Energy Institute, Ege University, Izmir, for the first time at the university level in Turkey. The Institute, built in 1986, has a livable floor area of 3000 m"2 and uses passive solar techniques. The heating and cooling loads of the room studied were 3.8 and 4.2 kW at design conditions, respectively. The system was commissioned in May 2000, and performance tests have been ...
Quantitative ecological risk assessment (ERA) is a means whereby the risk posed by a toxicant in any system can be evaluated by comparing the distribution of its measured or modelled concentrations (water quality data (WQD)) with available information on the range of concentrations that are known to adversely affect biota within that, or similar, habitats (dose-response data (DRD)). Initially, the WQD are compared with regulatory criteria (e.g. ANZECC and ARMCANZ, 2000). If they fail this test, then, on the assumption that both data sets comprise subsets of the entire range of concentrations, probability density functions are derived assuming a standard distribution form a typically log-normal. In this paper, AQUARISK has been used to estimate the risk posed by copper in effluent from the Rum Jungle mine site, pre- and post-remediation, and the proportion of taxa likely to be affected in the East Branch (EB) of the Finniss River downstream of ...
Immobilization of a model liquid organic pollutant, i.e. the 2-chloroaniline (2-CA), into a cement matrix using organoclays as pre-sorbent agents was investigated. Five cement-clay pastes were prepared with different nominal water-to-cement ratios (w/c=0.40, 0.25 and 0.15 wt/wt) and various amounts of waste (waste-to-cement o/c=0.20, 0.60 and 1.00 wt/wt); for comparison, a neat cement paste was also prepared. Dynamic leach tests were performed on solidified monoliths in order to assess the successful immobilization of the 2-CA. In monoliths at constant w/c ratio (0.40) the total amount of pollutant released increases with its initial content, and ranges from 15 to 35% with respect to it. By lowering w/c from 0.40 to 0.15 at constant o/c, the performances improved (<25% released). The microstructure of the hardened cement-clay pastes was characterized by quantitative X-ray diffraction (QXRD) and electronic microscopy (SEM-EDS) techniques; ...
Described herein are the results of the FY1994 research program for analysis and evaluation for thin film solar cells. The study on quantitative analysis of hydrogen atoms in a plasma determines quantity of hydrogen atoms in the plasma of monosilane diluted with hydrogen. It is found, contrary to expectation, that quantity of hydrogen atoms in the plasma decreases as it is more diluted with hydrogen. The study on light-induced degradation of the thin chlorine-base amorphous silicon films confirms that the plasma CVD method with 20% of dichlorosilane gas added to monosilane gas produces the thin amorphous silicon film 3 times faster than the conventional method. The thin film has essentially the same defect density as the one prepared by the conventional method, showing good photoelectric characteristics. The thin film of chlorinated amorphous silicon has a 1 digit lower defect density than the conventional one of amorphous silicon, as revealed by the accelerated ...
The relative potencies of 20 polychlorinated biphenyls (PCBs) were studied in a chicken embryo hepatocyte system. The 20 congeners were selected according to a full 2{sup 4}-factorial design based on the principal properties of all 154 tetra- through heptachlorinated PCBs. The principal properties were obtained using principal component analysis (PCA) on a multitude of different physico-chemical properties of the PCBs. Toxic equivalency factors (TEFs) were determined for seven out of the twenty PCB congeners, viz. PCB{number_sign}41, PCB{number_sign}60, PCB{number_sign}78, PCB{number_sign}126, PCB{number_sign}169, PCB{number_sign}190, and PCB{number_sign}193, which elicit measurable catalytic ethoxyresorufin-O-deethylase (EROD) activity in the chicken hepatocytes. A multivariate quantitative structure-activity relationship (QSAR) was developed by using partial least-squares to latent variables (PLS) in order to model the relationship between the set of ...
We present a sample preparation method for measuring magnesium in individual whole lymphocytes by electron probe X-ray microanalysis. We use Burkitt's lymphoma cells in culture as the test sample and compare X-ray microanalysis of individual cells with atomic absorption analysis of pooled cell populations. We determine the magnesium peak-to-local continuum X-ray intensity ratio by electron probe X-ray microanalysis and calculate a mean cell magnesium concentration of 39 +/- 19 mmol/kg dry weight from analysis of 100 cells. We determine a mean cell magnesium concentration of 34 +/- 4 mmol/kg dry weight by atomic absorption analysis of pooled cells in three cell cultures. The mean cell magnesium concentrations determined by the two methods are not significantly different. We find a 10% coefficient of variation for both methods of analysis and a 30% coefficient of variation in magnesium concentration among individual cells by electron probe X-ray microanalysis. We ...
We present a sample preparation method for measuring magnesium in individual whole lymphocytes by electron probe X-ray microanalysis. We use Burkitt's lymphoma cells in culture as the test sample and compare X-ray microanalysis of individual cells with atomic absorption analysis of pooled cell populations. We determine the magnesium peak-to-local continuum X-ray intensity ratio by electron probe X-ray microanalysis and calculate a mean cell magnesium concentration of 39 +- 19 mmol/kg dry weight from analysis of 100 cells. We determine a mean cell magnesium concentration of 34 +- 4 mmol/kg dry weight by atomic absorption analysis of pooled cells in three cell cultures. The mean cell magnesium concentrations determined by the two methods are not significantly different. We find a 10% coefficient of variation for both methods of analysis and a 30% coefficient of variation in magnesium concentration among individual cells by electron probe X-ray microanalysis. ...
A review of current daylighting design tools indicates that over 30 tools are now available, including nomographs, protractors, overlays, and programs for micro-, mini-, and mainframe computers. Computer-based tools allow testing and analyzing of more design alternatives under a wider variety of conditions than was previously practical with slower techniques, but they have not fundamentally changed the information available to the design professional. These tools are applicable to certain limited functions of the design process and do not address the varying information needs of the designer at various points in the design process. We describe a concept for a computer-based building envelope design tool that is structured to overcome many of the limitations of the existing tools. The tool would address daylighting design in the context of the overall building envelope design, covering a range of environmental quality issues in addition to ...
Quantitative evaluation of CRT and CR observations in indentification of malignancy using phantom and clinical data. A breast phantom and a total of 40 patients were imaged by Fuji computed radiography (FCR). The images were interpreted twice by six radiologists both on CR film (2510 x 2000 pixels x 10 bits, 0.1 mm spatial resolution) and on a CRT monitor (1568 x 1152 pixels x 10 bits, 0.1 mm pixel size with double expansion) with image processing parameters of a toutine (RN 1.0, RE 0.2), for a calcification (RN 9.0, RE 4.0) and for a mass (RN 7.0, RE 2.0). The forty clinical cases included breast diseases with calcifications, masses, and normal breasts. Two-tailed t-test was performed to analyze interpretation of simulated microcalcifications and masses in the phantom. The receiver operating characteristic (ROC) analysis was performed to evaluate clinical cases. In all interpretation studies using both breast phantom and clinical cases, there ...
We characterized the absorption and short-term translocation of cadmium (Cd) in rice (Oryza sativa ‘Nipponbare’) quantitatively using serial images observed with a positron-emitting...Full Text Available
A method for the quantitative determination of atmospheric hydroperoxyl radical comprising: (a) contacting a liquid phase atmospheric sample with a chemiluminescent compound which luminesces on contact with hydroperoxyl radical; (b) determining luminescence intensity from the liquid phase atmospheric sample; and (c) comparing said luminescence intensity from the liquid phase atmospheric sample to a standard luminescence intensity for hydroperoxyl radical. An apparatus for automating the method is also included.
Gas chromatography-selected ion monitoring-mass spectral analysis using [13C6]indole-3-acetic acid (IAA) as an internal standard provides an effective means for quantitation of...Full Text Available
A quantitative description is proposed for the depletion-induced slip thickness and velocity profile of a polymer solution near the wall-fluid interface in simple shear flow. The inhomogeneous polymer density profile at a flat wall is inserted into the equations of motion for the flow of a polymer solution near the flat wall. The theory is in quantitative agreement with simulation results. (letter to the editor)
An (Awassi × Merino) × Merino backcross family of 172 ewes was used to map quantitative trait loci (QTL) for different milk production traits on a framework map of 200 loci across all...Full Text Available
Studies have been performed with an anti-osteogenic sarcoma monoclonal antibody 791T/36 and human tumour xenografts to examine some of the quantitative and kinetic aspects of tumour localization. The influence of variations in tumour size and site and antibody dose on the extent and rate of specific antibody localization have been examined, together with the site of intratumoural deposition of the antibody. (UK).
In the context of safety assessment of radioactive waste repositories, complex radionuclide transport models covering key safety-relevant processes play a major role. In recent Swiss safety assessments, such as Kristallin-I, an important drawback was the limitation in geosphere modelling capability to account for geosphere heterogeneities. In marked contrast to this limitation in modelling capabilities, great effort has been put into investigating the heterogeneity of the geosphere as it impacts on hydrology. Structural geological methods have been used to look at the geometry of the flow paths on a small scale and the diffusion and sorption properties of different rock materials have been investigated. This huge amount of information could however be only partially applied in geosphere transport modelling. To make use of these investigations the 'PICNIC project' was established as a joint cooperation of PSI/Nagra and QuantiSci to provide a new geosphere transport ...
The need for noninvasive sensitive techniques for the diagnosis and follow-up of metabolic bone disease in dialysis patients has stimulated the author's interest in the efficacy of more detailed quantitative bone scintigraphy. Using hemodialysis to reduce elevated soft-tissue activity at scintigraphy, an attempt was made to assess the diagnostic sensitivity of quantitative bone scintigraphy as compared to qualitative bone scintigraphic, biochemical, radiographic and bone histologic studies. The second aim of these studies was to determine if one of the two major components of renal osteodystrophy is a major determinant for skeletal radiotracer uptake. The clinical observations on the efficacy and possible specificity of quantitative bone scintigraphy in the diagnosis and follow-up during treatment of renal osteodystrophy are presented briefly in this chapter. Thus, the use of scintigraphy for the routine detection and ...
The CASTOC project addresses environmentally assisted cracking (EAC) phenomena in low alloy steels used for pressure boundary components in both Western type boiling water reactors (BWR) and Russian type pressurised water reactors (VVER). It comprises the four work packages (WP): inter-laboratory comparison test (WP1); EAC behaviour under static load (WP2), EAC behaviour under cyclic load and load transients (WP3); evaluation of the results with regard to their relevance for components in practice (WP4). The use of sophisticated test facilities and measurement techniques for the on-line detection of crack advances have provided a more detailed understanding of the mechanisms of environmentally assisted cracking and provided quantitative data of crack growth rates as a function of loading events and time, respectively. The effect of several major parameters controlling EAC was investigated with particular emphasis on the ...
We consider the case of a test sphere (ball) of radius a{sub 1} rotating at constant angular velocity {omega} in an otherwise quiescent unbounded suspension of uniformly sized spheres of radii a{sub 2} dispersed in a Newtonian fluid of viscosity {mu}. To the first order in the volume fraction c of suspended spheres it is shown that when the ball is small compared with the suspended spheres the suspension does not behave as regards the hydrodynamic torque L exerted on the ball like a homogeneous Newtonian fluid characterized by the usual Einstein viscosity coefficient {mu}{sub s}={mu}(1+5/2c). Explicitly, the torque on the rotating sphere does not obey Kirchoff{close_quote}s law, L=8{pi}{mu}{sub s}a{sub 1}{sup 3}{omega} for no slip. Rather, a modified form of Kirchoff{close_quote}s law is obtained in which the Einstein coefficient of 5/2 is multiplied by a coefficient which is less than unity in magnitude and is functionally dependent only upon the ...
IntroductionBreast cancer is the most diagnosed and second leading cause of cancer deaths in the U.S. female population. An estimated 5 to 10 percent of all breast cancers are inherited, caused by mutations in the breast cancer susceptibility genes (BRCA1/2). As many as 90% of all mutations are nonsense mutations, causing a truncated polypeptide product. A popular and low cost method of mutation detection has been the protein truncation test (PTT), where target regions of BRCA1/2 are PCR amplified, transcribed/translated in a cell-free protein synthesis system and analyzed for truncated polypeptides by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) and autoradiography. We previously reported a novel High Throughput Solid-Phase PTT (HTS-PTT) based on an enzyme-linked immunosorbent assay (ELISA) format that eliminates the need for radioactivity, SDS-PAGE and subjective interpretation of the results. Here, we report the next generation HTS-PTT ...
Transmission nuclear resonance fluorescence measurements were made on targets consisting of Pb and depleted U with total areal densities near 86g/cm"2. The "2"3"8U content in the targets varied from 0% to 8.5% (atom fraction). The experiment demonstrates the capability of using transmission measurements as a non-destructive technique to identify and quantify the presence of an isotope in samples with thicknesses comparable to the average thickness of a nuclear fuel assembly. The experimental data also appear to demonstrate the process of notch refilling with a predictable intensity. Comparison of measured spectra to previous backscatter "2"3"8U measurements indicates general agreement in observed excited states. Evidence of two new "2"3"8U excited states and possibly a third state have also been observed.
A new implementation of a shear-force microscope is described that uses a shear-force detection system to perform topographical imaging of large areas (#approx#1x1 mm"2). This implementation finds very interesting application in the study of archeological or artistic samples. Three dc motors are used to move a sample during a scan, allowing the probe tip to follow the surface and to face height differences of several tens of micrometers. This large-area topographical imaging mode exploits new subroutines that were added to the existing homemade software; these subroutines were created in Microsoft VISUAL BASIC 6.0 programming language. With this new feature our shear-force microscope can be used to study topographical details over large areas of archaeological samples in a nondestructive way. We show results detecting worn reliefs over a coin.
An x-ray diffraction technique for determining thin-film thickness is presented which should prove to be a valuable alternative to the array of spectroscopies (Rutherford backscattering spectrometry, Auger electron spectroscopy, etc.) currently favored for these measurements. Some of the virtues of this x-ray diffraction approach are its nondestructive nature, fast data acquisition rate (enabling in situ observations), thickness resolution better than 5 nm, and conventional equipment requirements. Results are shown for Pd/sub 2/Si thin films grown during isothermal annealing of Pd coatings (100 nm) on Si at 200 /sup 0/C for various amounts of time. A comparison of these x-ray measurements with Rutherford backscattering spectrometry data taken from the same specimens is used to demonstrate the validity of the x-ray technique.
The excitation functions of the reactions "9"8Mo(d,p)"9"9Mo and "1"0"0Mo(d,p)"1"0"1Mo have been determined by irradiation of stacked foils with deuterons of energies less than 13 MeV and non-destructive determination of the absolute activity of the Mo radioisotopes by semiconductor #gamma#-ray spectrometry. From the excitation functions, the thick-target yields and the saturation production rates of "9"9Mo and "1"0"1Mo for deuteron energies of 13.0 MeV and 11.7 MeV have been calculated. Implications for the production of "9"9Mo for generators of sup(99m)Tc are discussed. (author).
X-ray diffraction offers a unique combination of advantages for kinetic study which include the non-destructive nature of the measurement, the use of bulk crystals, and the convenience of the experimental arrangements. These attributes and the availability of position-sensitive detectors and high-flux synchrotron radiation sources make this technique most useful for in situ, dynamical investigations. When using diffraction techniques to determine a diffusion coefficient, the principle of analysis entails a scattering theory and a kinetic model. The former allows the kinetic parameter(s) to be extracted from measured intensity, while the latter relates the kinetic parameter(s) to the diffusion coefficient(s). Three examples are demonstrated: (1) Palladium Silicide (Pd{sub 2}Si) Layer Growth on Silicon, (2) Decomposition of an Ni-12.5at%Si Superalloy, and (3) Short-range Ordering in Cu-Au Solid Solutions.
The detection and characterization of deeply buried fatigue damage in thick, multi-layer airframe components pose significant technical challenges to the aviation safety community. Currently, no nondestructive evaluation technique is available to reliably detect such potential damage from the exterior of the airframe, which is highly desirable in light of inspection cost as well as avoidance of structure damage. Recent technological advances in high-sensitivity magnetic sensors, i.e., spin-dependent tunneling (SDT) sensors, make it feasible to employ electromagnetic inspection techniques for deep fatigue crack inspection. In this work, we report on the development and fabrication of a low frequency eddy current probe based on a magnetically shielded SDT pickup sensor concentrically located...
This paper aimed to the evaluation of different kinds of sorbent material preparation and to the evaluation of their characteristics at different pH conditions by X-ray fluorescence analysis. This method is suitable for identification and determination of elements in samples of different character, state and origin because it is a polycomponent, non-destructive, fast and simple analytical method. Moreover, it allows timeadvantageous and reliable measurements. This paper studies problems concerning the determination of some selected elements (Mn, Fe, Ni, Cu, Zn, Pb) in pharmaceutical samples of sodium chloride in the solid state as well as in its solution by sorption on chelating extraction membrane 3M Empore"T"M and on the strongly acidic ion-exchanger Dowex 50Wx8. Conditions for the most effective sorption of determined elements are also interpreted. (author)
This paper aimed to the evaluation of different kinds of sorbent material preparation and to the evaluation of their characteristics at different pH conditions by X-ray fluorescence analysis. This method is suitable for identification and determination of elements in samples of different character, state and origin because it is a polycomponent, non-destructive, fast and simple analytical method. Moreover, it allows time-advantageous and reliable measurements. This paper studies problems concerning the determination of some selected elements (Mn, Fe, Ni, Cu, Zn, Pb) in pharmaceutical samples of sodium chloride in the solid state as well as in its solution by sorption on chelating extraction membrane 3M Empore? and on the strongly acidic ion-exchanger Dowex 50Wx8. Conditions for the most ef...
This study assesses the current state of undergraduate instruction in empirical research methods in communication and offers recommendations for enhancing such instruction. Responses to an online questionnaire were received from 149 communication-related programs at four-year colleges and universities. Just over 85% of responding programs offered an empirical methods course. Although the course often covered both qualitative and quantitative methods, instruction was heavily slanted toward quantitative methods and topics common to both qualitative and quantitative inquiry. The empirical methods course was usually required for graduation, but it was typically not well integrated with the rest of the curriculum and taken late in students' undergraduate careers. Additional analyses examined st...
Fifteen quantitative bone scintigraphies were performed in an adolescent girl during the follow-up of a femoral osteogenic sarcoma treated by chemotherapy and massive allograft. Three hours after injection of the radiopharmaceutical (7.4 MBq/kg of 99mTc-MDP) bone activity was measured in the inferior limbs at several regions of interest centered on the hips, femurs (proximal, middle, distal) and proximal tibias. The variations of relative bone activities A/S (ratio of corresponding counting rates between two homologous regions in the affected A and in the healthy S limb) and of absolute bone activities (expressed in counts/pixel-second) are interpreted as a function of times during treatment. The quantitative results are discussed with regard to main phenomena influencing bone activity in this particular clinical case: bone growth, chemotherapy and neo-osteogenesis in allograft.
The Pacific white shrimp, Litopenaeus vannamei, is the most important shrimp species in volume in world aquaculture. However, in recent decades, outbreaks of diseases, especially viral diseases, have led to significant economic losses, threatening the sustainability of shrimp farming worldwide. In 2004, Brazilian shrimp farming was seriously affected by a new disease caused by the Infectious myonecrosis virus (IMNV). Thus, disease control based on rapid and sensitive pathogen detection methods has become a priority. In this study, a specific quantitation method for IMNV was developed using real-time PCR with SYBR Green chemistry and viral load of the principal target tissues of chronically infected animals was quantified. The quantitative analysis revealed that mean viral load ranged from ...
During the past three years the program has undergone a substantial revitalization. There has been no significant change in the scientific direction of this grant, in which emphasis continues to be placed on developing new or improved methods of obtaining quantitative data from radiotracer imaging studies. However, considerable scientific progress has been made in the three areas of interest: Radiochemistry, Quantitative Methodologies, and Experimental Methods and Feasibility Studies, resulting in a sharper focus of perspective and improved integration of the overall scientific effort. Changes in Faculty and staff, including development of new collaborations, have contributed to this, as has acquisition of additional and new equipment and renovations and expansion of the core facilities. 121 refs., 30 figs., 2 tabs.
To more accurately measure fluorescent signals from microarrays, we calibrated our acquisition and analysis systems by using groundtruth samples comprised of known quantities of red and green gene-specific DNA probes hybridized to cDNA targets. We imaged the slides with a full-field, white light CCD imager and analyzed them with our custom analysis software. Here we compare, for multiple genes, results obtained with and without preprocessing (alignment, color crosstalk compensation, dark field subtraction, and integration time). We also evaluate the accuracy of various image processing and analysis techniques (background subtraction, segmentation, quantitation and normalization). This methodology calibrates and validates our system for accurate quantitative measurement of microarrays. Specifically, we show that preprocessing the images produces results significantly closer to the known ground-truth for these samples.
Abstract Rationale, aims and objectives- Finding ways to incorporate disparate types of evidence into research syntheses has the potential to build a better evidence base for clinical practice and policy. Yet conducting such mixed research synthesis studies is challenging. Researchers have to determine whether and how to use adjusted and unadjusted quantitative findings in combination with each other and with qualitative findings. Methods- Among quantitative findings, adjustment for confounding, either via study design or statistical analysis, can be a considerable source of heterogeneity. Yet there is no consensus about the best way to synthesize findings resulting from different methods for addressing confounding. When synthesizing qualitative and quantitative findings, additional consid...
The procedure describes the procedures to be used in evaluating consumable and combustible cartridge cases. Included are ballistic tests, environmental tests, adverse condition tests, fungus resistance tests, drop tests and safety tests. (Author)
A method for detecting electrons emitted as secondary particles by photon incidence to a specimen, as well as a method of using the photons emitted by electron incidence as detecting particles are explained. Pd-Si(100)2{times}1 system is adopted for a case study of using photo-electron spectroscopy where synchrotron emitted light in soft X-ray region is used as the incident light. Pd atoms are deposited little by little on clean Si surface to investigate the electron structure of the surface, and the interface electron structure after bonded formation of Pd(thin film)-Si(substrate) is estimated. Radiation soft X-ray spectroscopy is employed to observe the real state of the bonded interface of Pd(thin film)-Si(substrate) prepared by depositing Pd film in a short period of time. In the case of radiation soft X-ray spectroscopy with electron beam excitation, bonded system of thin film and substrate can be investigated by nondestructive analysis even when the film ...
The population doses and risks of stochastic effects from occupational exposures in Japan in 1978 were estimated on the basis of a nation-wide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 82,500 workers other than the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the offitial publication of the Japan Nuclear Safety Commission. The total number of workers except for nuclear power stations was estimated to be about 170,000 persons. Radiation works were subdivided as follows: medical works including dental; nondestructive inspectional; non-atomic energy industrial; research and educational; atomic energy industrial and nuclear power industrial. The annual collective dose equivalents were estimated to be about 6,000 man rem for medical workers, 450 man rem for non-destructive inspectional, 450 man rem for ...
BackgroundA common approach to understanding the genetic basis of complex traits is through identification of associated quantitative trait loci (QTL). Fine mapping QTLs requires...Full Text Available
In proteomics, one-dimensional (1D) SDS-PAGE is widely used for protein fractionation prior to mass spectrometric analysis to enhance dynamic range of analysis and to improve identification...Full Text Available
A comparative and quantitative study of the tissue distribution of brain-thymus shared antigens was carried out using rabbit antisera to rat, dog and human brain homogenates, assayed on rat, dog and...Full Text Available
SummaryIn vivo tumor cell migration through integrin-dependent pathways is key to the metastatic behavior of malignant cells. Using quantitative in vivo...Full Text Available
Neuroblasts born in the adult subventricular zone (SVZ) migrate long distances in the rostral migratory stream (RMS) to the olfactory bulbs where they integrate into circuitry as functional interneurons....Full Text Available
In order to maintain a safe operation and availability of generating facilities, qualitative and quantitative assessment of piping vibration was performed vibration sources and damages of piping support was identified on the second piping system of Wolsun...
The quantitative experimental uncertainty in the structure of fully hydrated, biologically relevant, fluid (Lα) phase lipid bilayers has been too large to...Full Text Available
An antigen-antibody system of polystyrene tubes coated with immunoglobulin antibody was used for quantitating immunoglobulins. A similar radioimmunoassay method was adapted for a viral antigen-antibody...Full Text Available
French ... Orig. Title Scintigraphie osseuse quantifiee chez l'enfant et l'adolescent - repartition selon l'age des taux de fixation de diverses pieces osseuses normales.
Thirty-four patients with prostatic carcinoma were studied with quantitative bone scintigraphy and whole-body counting (WBC) 1 and 24 h after injection of [sup 99m]Tc-MDP before as well as two weeks and two months after orchiectomy. Thirteen of the patients had normal bone scintigrams and WBR at the three different investigations; 21 had skeletal metastases. The latter showed throughout the study higher local gamma camera count rates as well as WBR values than the patiens with normal scintigrams. In these patients a ''flare phenomenon'', with an increase in count rate two weeks after orchiectomy followed by a decrease two months post-operatively, was seen with quantitative bone scintigraphy but not with WBC. However, WBC may be a valuable method indicating the total extent of skeletal metastases in the body, while quantitative bone scintigraphy is more accurate in the interpretation of ...
Thirty-four patients with prostatic carcinoma were studied with quantitative bone scintigraphy and whole-body counting (WBC) 1 and 24 h after injection of "9"9"mTc-MDP before as well as two weeks and two months after orchiectomy. Thirteen of the patients had normal bone scintigrams and WBR at the three different investigations; 21 had skeletal metastases. The latter showed throughout the study higher local gamma camera count rates as well as WBR values than the patiens with normal scintigrams. In these patients a ''flare phenomenon'', with an increase in count rate two weeks after orchiectomy followed by a decrease two months post-operatively, was seen with quantitative bone scintigraphy but not with WBC. However, WBC may be a valuable method indicating the total extent of skeletal metastases in the body, while quantitative bone scintigraphy is more accurate in the interpretation of individual skeletal metastases. (orig.).
Background In May 2000, AstraZeneca launched a Web service for asthma patients and health-care providers called LinkMedica, which includes an asthma diary for...Full Text Available
1. A combined pharmacokinetic-pharmacodynamic model has been used to analyse the relationship between QT prolongation and changes in plasma concentration which occurred after disopyramide was given...Full Text Available
Forty-six patients with end-stage renal failure were subjected to iliac crest biopsy before the initiation of a dialysis programme and regardless of the presence of skeletal symptoms....Full Text Available
Striped bass (Morone saxatilis) in the Chesapeake Bay are currently experiencing a very high prevalence of mycobacteriosis associated with newly described Mycobacterium...Full Text Available
Binding of epidermal growth factor (EGF) to the EGF receptor (EGFR) initiates signal transduction, ultimately leading to altered gene expression. Ligand-activated EGFR is also rapidly internalized...Full Text Available
In a Swedish community-based program for the treatment of dental phobic patients, a clinical trial was performed among 99 severely phobic individuals with long-standing avoidance of dental treatment....Full Text Available
We report the first quantitative assessment of electrosprayed droplet/ion focusing enabled by the use of a voltage-assisted air amplifier between an electrospray ionization emitter and a hybrid...Full Text Available
How transcription factors interpret the cis-regulatory logic encoded within enhancers to mediate quantitative changes in spatiotemporally restricted expression patterns during animal...Full Text Available
Dissecting the genes involved in complex traits can be confounded by multiple factors, including extensive epistatic interactions among genes, the involvement of epigenetic regulators, and the variable...Full Text Available
The A(..pi../sup +/,/sup 3/He)B reaction near threshold is studied in a model where the pion is absorbed by an /sup 4/He constituent of the target nucleus. The predictions of this model using harmonic oscillator cluster wave functions agree semi-quantitatively with the experimental data on the inverse reaction.
This study investigated weathering effects on polyvinyl chloride (PVC) based wood plastic composites (WPC), with a focus on the color and structure that is attributed to the material composition. It is directed towards quantifying the main chemical modifi...
Recent experiments have provided new quantitative measurements of the rippling phenomenon in fields of developing myxobacteria cells. These measurements have enabled us to develop a mathematical model...Full Text Available
Aims:To Study the religious and ideological views and practice of Palliative Care physician towards Euthanasia.Materials and Methods:An...Full Text Available
Skeletal radiotracer (sup(99m)Tc-HEDP) uptake was quantitated with and without the aid of a computer in 30 chronic dialysis patients with histologic evidence of renal osteodystrophy. Before scintigraphy, elevated soft-tissue activity due to the absence of renal radiotracer excretion was reduced by hemodialysis. The results were compared with those of a normal group and with the results of the biochemical and the bone morphometric studies of these patients. In all patients the radiotracer uptake was elevated, often markedly. In several patients with minimal histologic bone disease, however, soft-tissue activity could not be normalized by hemodialysis although its influence on the quantitative data could be further reduced (but not excluded) by computer evaluation of skeletal radiotracer uptake. Since the latter technique clearly distinguished the majority of the patients from the normals, it appears that computerized ...
Skeletal radiotracer (sup(99m)Tc-HEDP) uptake was quantitated with and without the aid of a computer in 30 chronic dialysis patients with histologic evidence of renal osteodystrophy. Before scintigraphy, elevated soft-tissue activity due to the absence of renal radiotracer excretion was reduced by hemodialysis. The results were compared with those of a normal group and with the results of the biochemical and the bone morphometric studies of these patients. In all patients the radiotracer uptake was elevated, often markedly. In several patients with minimal histologic bone disease, however, soft-tissue activity could not be normalized by hemodialysis although its influence on the quantitative data could be further reduced (but not excluded) by computer evaluation of skeletal radiotracer uptake. Since the latter technique clearly distinguished the majority of the patients from the normals, it appears that computerized ...
Based on a generalized theory of perturbations and on non-linear programming an approach to the quantitative determination of necessary accuracies for nuclear data is described. It is used to calculate transactinide isotope build-up in reactors.
BackgroundPlant biologists have long speculated about the mechanisms that guide pollen tubes to ovules. Although there is now evidence that ovules emit a diffusible attractant, little...Full Text Available
BackgroundArtemisinin-based combination therapy, currently considered the therapy of choice for uncomplicated Plasmodium falciparum malaria in endemic countries,...Full Text Available
The localization of gold in the synovial membrane of rheumatoid arthritis patients treated with sodium aurothiomalate was examined and quantitative analysis of epon-embedded sections was carried out...Full Text Available
A fluid-phase immunoradiometric assay has been developed which identifies an antigen on the Factor VIII (antihemophilic factor) procoagulant protein. This sensitive and quantitative assay is not influenced...Full Text Available
Purpose: Understanding the kinetics of tumor growth∕shrinkage represents a critical step in quantitative assessment of therapeutics and realization of adaptive radiation therapy....Full Text Available
A novel, quantitative method for detecting poly-3-hydroxybutyrate (PHB) amounts in viable cells was developed to allow for high-throughput screening of mutant libraries. The staining technique was demonstrated...Full Text Available
Our increasing capabilities for quantitative hormone analysis and automated high resolution growth studies have allowed a reassessment of the classical Cholodny-Went hypothesis of gravitropism. According...Full Text Available
BackgroundThe decline noticed in several fertility traits of dairy cattle over the past few decades is of major concern. Understanding of the genomic factors underlying fertility,...Full Text Available
Quantitative probing of heterogeneous regions in muscle is feasible with phosphorus-31 magnetic resonance spectroscopy because of the differentiation of metabolic patterns of glycolytic and oxidative...Full Text Available
The changes in conjugated indole-3-acetic acid (IAA) levels compared to the levels of free IAA have been analyzed during the development of bean (Phaseolus vulgaris L.) seed using quantitative...Full Text Available
Studies were conducted to quantitate the evolution of nitrogen oxides (NO(x)) from soybean [Glycine max (L.) Merr.] leaves during in vivo nitrate reductase...Full Text Available
Pseudomonas mandelii liquid cultures were studied to determine the effect of pH and temperature on denitrification gene expression, which was quantified by quantitative reverse transcription-PCR....Full Text Available
A liquid chromatography/tandem mass spectrometric (LC/MS/MS) assay was developed for the quantitative determination of salirasib (S-trans, trans-farnesylthiosalicylic acid,...Full Text Available
Experimental and imaging studies in monkeys have outlined various long association fiber bundles within the temporoparietal region. In the present study the trajectory of the middle longitudinal fascicle...Full Text Available
Qualitative and quantitative aspects of the mechanisms involved in the regulation of cytoplasmic pH during an acid-load have been studied in Acer pseudoplatanus cells. Two main processes,...Full Text Available
Motivation: Cell tracking is an important method to quantitatively analyze time-lapse microscopy data. While numerous methods and tools exist for tracking cells in 2D time-lapse images,...Full Text Available
Quantitative metallography is often used to confirm the proper processing of aerospace metallic materials. A microstructural feature of great importance for titanium alloys processed in the alpha-beta phase field is the volume fraction of primary alpha. S...
Activatable or “smart” magnetic resonance contrast agents have relaxivities that depend on environmental factors such as pH or enzymatic activity, but the MR signal depends on...Full Text Available
A bedload trap in the riverbed provided direct quantitative measurement of debris-transport rate in the East Fork River, Wyoming, a basin of 466 km2 drainage area. Traction load moves only...Full Text Available
BackgroundKinematic and kinetic measurements used in laboratory settings can quantify upper extremity movement impairment following stroke, but their relationship...Full Text Available
We used tryptophan auxotrophs of the dicot Arabidopsis thaliana (wall cress) to determine whether tryptophan has the capacity to serve as a precursor to the auxin, indole-3-acetic acid (IAA). Quantitative...Full Text Available
In nuclear fuel with a burn-up of 33 kg/t U and 52 kg/t U 15 transuranium nuclides /sup 237/Np to /sup 246/Cm have been determined by alpha and gamma spectroscopy after radiochemical separation.
Arbuscular mycorrhizal fungi (AMF) are obligate biotrophs, known to play an important role in ecological processes. Conventional light microscopy is the most common method used to detect their presence...Full Text Available
Numbers of non-indigenous species--species introduced from elsewhere - are increasing rapidly worldwide, causing both environmental and economic damage. Rigorous quantitative risk-analysis frameworks,...Full Text Available
The 52 papers discuss the following subjects: 1. Preparation and structural development; 2. Structural constitution; 3. Structural formation and phase transition; 4. Structure and mechanical properties; 5. Structural formation of metallic and nonmetallic materials; 6. Quantitative metallography, and 7. Quality assurance.
DNA antoantibodies in serum will bind to antigen-coated polystyrene tubes and can be detected by radiolabelled anti-immunoglobulin. The method is quantitative, gives information on the antibody class...Full Text Available
BackgroundCerebral malaria (CM) is a neurological syndrome that includes coma and seizures following malaria parasite infection. The pathophysiology is not fully understood and cannot...Full Text Available
A control group of geese (Anser anser) on a normal calcium diet for egg laying poultry was compared to egg laying geese on a calcium deficient diet. The ultimate compressive strength and modulus of elasticity of femoral cortical bone from each group were determined by compressing right circular cylinders which were 2.4 mm in height and 0.8 mm in diameter. The bending strength and bending modulus of elasticity of tibial cortical bone were determined by three point bend tests on rectangular prisms which were approximately 25 mm by 0.8 mm by 0.8 mm. Bone calcium content and eggshell calcium content were determined by atomic absorption spectrophotometry. Blood samples were analyzed for free calcium ion concentration. Histological observations included studies of cross-sectional microradiographs, examinations of cross sections stained by a modified Masson's technique, and a determination of fractional area of voids by quantitative microscopy. The ...
A probabilistic precursor study provides a complement to the 'root cause' analysis approach by focusing on how an event might have developed adversely, and implies the mapping of an operational event on a probabilistic risk model of the plant in order to obtain a quantitative assessment of the safety significance of the event. In order to benefit from state-of-the-art PSA features but also to assure repeatability of the analysis, a comprehensive set of PSAEA guidelines was developed. This PSAEA procedure was established in 1996-1998 by Enconet Consulting in the framework of an international project on behalf of - and involving - the nuclear regulatory bodies from 6 countries: AECB (Canada), AVN (Belgium), CSN (Spain), HSK (Switzerland), NII (United Kingdom) and SKI (Sweden). The PSAEA procedure defines preliminary requirements for the PSA model and code, and identifies input requirements such as information on plant status, event sequence chronology and causes. The ...
The aim of this paper was to describe ability to intercalation of laboratory prepared carbon composites and their constituents. In work the following materials were tested; pinch-based fibres of P-120 and K-1100 manufacturer's designations, carbon matrix and resulting composites. To prepare a matrix of composites, phenol-formaldehyde resin (Z) and pinch-based precursor (PAK) were used. After initial carbonization, the carbon matrix was heated to 2150 "oC i to improve ability to the future intercalation. Three kinds of composites (P/Z, K/Z and K/PAK), with two directional reinforcement (2D), were prepared. All carbon samples were intercalated with copper chloride(II). To study the structure of all materials, before and after intercalation, X-ray diffraction method was used. It enabled to measure microstructure parameters (L_c and L_a), interplanar distance (d_0_0_2) thickness of an intercalation layer (d_i). Before intercalation, graphite fibers are characterized by ...
There has been increased theoretical and experimental research interest in autonomous mobile robots exhibiting cooperative behaviour. This paper provides consistent quantitative measures of organizational degree of a two-dimensional environment. We proved, by the way of numerical simulations, that the theoretically derived values of the feature are reliable measures of aggregation degree. The slope of the feature's dependence on memory radius leads to an optimization criterion for stochastic functional self-organization. We also described the intellectual heritages that have guided our research, as well as possible future developments. (author)
An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.
An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.
A technique for quantitative analysis of growth plates in varus or valgus deformity about the knee has been developed. Computer-generated regions of interest are placed on magnification scintigraphs to divide distal femoral and proximal tibial physes into four equal segments. The ratio of counts in the medial half to counts in the lateral half was studied in 31 children (22 normal, 9 with angular deformity). Normal ratios were 0.74 to 0.98 for femora and 0.98 to 1.20 for tibias. In eight of nine patients with deformity, the ratio was abnormal; in two patients the ratio returned to normal when the deformity ceased to progress.
The authors experimentally study the separate stages of the determination of iodine in thyroidin by the combustion method in a flask with oxygen. The monotypic, conventional procedures and the procedure of Kolii and Pakhomov were studied. With addition of potassium iodide, a sixfold amount (compared with the initial) of iodine is liberated. Further, the liberated iodine is titrated by sodium thiosulfate. The authors find the degree of influence of a high nitrogen content on the determination of iodine in organic compounds. The procedure developed for the quantitative determination of the iodine in thyroidin by the combustion method is simple, fairly rapid, and can be used for the reliable control of the quality of thyroidin preparations and its starting raw material.
The ultimate compressive strength of 36 thoracolumbar vertebrae was determined experimentally. In addition, the trabecular bone mineral content was measured by single energy quantitative computed tomography. The areas of fractured endplates were also determined by computed tomography. The results show that a linear relationship exists between the compressive strength and the product of bone density and endplate area. These data allow an in vivo prediction of vertebral body strength using a noninvasive method with a standard error of estimate amounting to less than 0.95 kN. PMID:3212488
The investigation of the petroleum contamination in marine organisms requires the trace level quantitative determination of indicative substances to be identified by a fingerprint of petroleum. Polymethylnaphthalene (PMN) and polymethylphenanthrene (PMP) were chosen because of their simple separation from a crude oil by means of an activated charcoal chromatography, their relatively high existence in aromatic compounds, and their persistence relative to other petroleum components in the tissue of oil contaminated marine organisms. The purpose of this paper is to present an activated charcoal chromatographic separation procedure of PMN and PMP in a crude oil and a trace level quantitative analytical method of them in marine organisms by mass fragmentography (MF).
This paper is aimed to present a fuzzy decision making approach to deal with the performance measurement in supply chain systems. In the manufacturing environment, performance measurement is based on different quantitative and qualitative factors. Some of these factors may have a larger effect on the performance measure than others. Units of measure of the quantitative factors are different such as time, money, percentage, ratio, and counts. Thus, this paper presents a performance measurement approach based on fuzzy set theory and the pair-wise comparison of Analytical Hierarchy Process (AHP), which ensures the consistency of the designer's assignments of importance of one factor over another to find the weight of each of the manufacturing activity in the departmental organization. In the ...
Sixteen patients with PAGET's disease of bone underwent quantitative bone scintigraphy with "9"9"mTc-MDP before and after a long-term treatment with carbocalcitonin, a synthetic analogue of eel calcitonin. The radionuclide study consisted in the blood pool and bone uptake measurement and in the bone avidity calculation (bone uptake - blood pool ratio). In our patients, a significant decrease in bone uptake and bone avidity was found, whereas the blood pool remained statistically unchanged. This behaviour could be accounted for the shift of the compact bone to a lamellar pattern. (orig.).
Sixteen patients with PAGET's disease of bone underwent quantitative bone scintigraphy with /sup 99m/Tc-MDP before and after a long-term treatment with carbocalcitonin, a synthetic analogue of eel calcitonin. The radionuclide study consisted in the blood pool and bone uptake measurement and in the bone avidity calculation (bone uptake - blood pool ratio). In our patients, a significant decrease in bone uptake and bone avidity was found, whereas the blood pool remained statistically unchanged. This behaviour could be accounted for the shift of the compact bone to a lamellar pattern.
The objective of Configuration Risk Management Program(CRMP) is to maintain the safety level by assuring the defense-in-depth of nuclear power plant while the configurations are changed during plant operations, especially for the LP/SD. Such a safety purpose can be achieved by establishing the risk monitoring programs with both quantitative and qualitative features. Generally, the quantitative risk evaluation models, i.e., PRA models are used for the risk evaluation during full power operation, and the qualitative risk evaluation models such as safety function assessment trees are used. Through this study, safety function assessment trees were developed.
NO{sub x} compounds, specifically NO and NO{sub 2}, are pollutants and potent greenhouse gases. Compact and inexpensive NO{sub x} sensors are necessary in the next generation of diesel (CIDI) automobiles to meet government emission requirements and enable the more rapid introduction of more efficient, higher fuel economy CIDI vehicles. Because the need for a NO{sub x} sensor is recent and the performance requirements are extremely challenging, most are still in the development phase. Currently, there is only one type of NO{sub x} sensor that is sold commercially, and it seems unlikely to meet more stringent future emission requirements. Automotive exhaust sensor development has focused on solid-state electrochemical technology, which has proven to be robust for in-situ operation in harsh, high-temperature environments (e.g., the oxygen stoichiometric sensor). Solid-state sensors typically rely on yttria-stabilized zirconia (YSZ) as the oxygen-ion conducting electrolyte and then target ...
Austenitic stainless steel (18% Cr, 12% Ni, Mo gradation between 0,06 to 3,6%) had been solution nitrided. By step-by-step removing, the samples could be prepared with various surface contents of nitrogen from 0.04 to 0.42%. In two test series the influence of nitrogen had been determined. The susceptibility against pitting corrosion of these samples had been tested by the chronopotentiostatical method. For the investigated steel composition and the used corrosion system there is no influence of molybdenum on the effectiveness of nitrogen. The effectiveness of nitrogen can be described by the factor 25 in the PRE. By the investigation of the surfaces with the XPS analysis, it could be shown that the passivation and the pit nucleation is influenced by nitrogen. In these ranges NO{sub x}, NH{sub x}, and NH{sub z}-spectra have been detected. Bound Mo was found in steels containing molybdenum. It is assumed that the repassivation mechanisms of N ...
Radionuclide X-ray fluorescence analysis is a method, which has many advantages for analysing various historic artefacts, as it is relatively cheap, sensitive and non-destructive, and it allows measurements in-situ. However, this analysis has also certain limitations especially concerning sensitivity to chemical elements only, irrespective of the compounds or chemical forms in which these elements have been bonded. In addition, light elements emitting very soft X-rays cannot be measured, and in order to detect a wide range of elements, it is necessary to carry out repeated measurements with different radiation sources. Despite these limitations, valuable information can be obtained about the composition of historic materials and data about the origin and age of these artefacts can be derived. Analyses of wall paintings, ancient metal sculptures or other objects of art provide the basis for historic considerations documented in our results for some objects belonging ...
Radionuclide X-ray fluorescence analysis is a method, which has many advantages for analysing various historic artefacts, as it is relatively cheap, sensitive and non-destructive, and it allows measurements in-situ. However, this analysis has also certain limitations especially concerning sensitivity to chemical elements only, irrespective of the compounds or chemical forms in which these elements have been bonded. In addition, light elements emitting very soft X-rays cannot be measured, and in order to detect a wide range of elements, it is necessary to carry out repeated measurements with different radiation sources. Despite these limitations, valuable information can be obtained about the composition of historic materials and data about the origin and age of these artefacts can be derived. Analyses of wall paintings, ancient metal sculptures or other objects of art provide the basis for historic considerations documented in our results for some objects belonging ...
High-spatial-resolution microfocus-based X-ray imaging technology, both real-time and film, has been used to study the thickness variation that occurs in the oxide core of silver-sheathed BSCCO ribbons produced by the powder-in-tube method. This thickness variation (also called ``sausaging``) occurs during incremental rolling and degrades the critical current densities of the ribbons. Using X-ray image data the authors determined the onset and severity of sausaging. Onset occurred at a ribbon thickness of 203 {micro}m, and the severity increased with subsequent rolling reductions. Scanning electron microscopy was used to confirm the X-ray image data. X-ray imaging provides several advantages over more traditional methods for characterizing the superconductors such as optical or scanning electron microscopy. The X-ray imaging provides nondestructive information about the entire width of the ribbon, with far greater speed, lower cost, and more flexibility than the ...
Nanoimprinting is a fast-growing technique for nanoscale patterning. One of the remaining issues in nanoimprinting is the removal of the residual layer after nanoimprinting. Traditionally the residual layer is removed by an oxygen reactive-ion etching (RIE) step. The need for a vacuum environment and dedicated equipment in this step lowers the throughput and increases the cost of the nanoimprinting process. It also prevents the possibility of patterning isolated functional polymers because oxygen RIE destroys the functional materials. In this work, novel nanoimprinting schemes are developed to nondestructively remove the residual layer in thermal nanoimprinting by solvent developing and dewetting. Combined with a transfer-bonding technique, three-dimensional polymer scaffolds are achieved. The techniques developed here eliminate the RIE step in thermal nanoimprinting and are compatible with roller nanoimprinting for large-scale patterning of polymer micro- or ...
The presence of residual stresses in engineering components can significantly affect their load carrying capacity and resistance to fracture. In order to quantify their effect it is necessary to know their magnitude and distribution. Neutron diffraction is the most suitable method of obtaining these stresses non-destructively in the interior of components. In this paper the principles of the technique are described. A monochromatic beam of neutrons, or time of flight measurements, can be employed. In each case, components of strain are determined directly from changes in the lattice spacings between crystals. Residual stresses can then be calculated from these strains. The experimental procedures for making the measurements are described and precautions for achieving reliable results discussed. These include choice of crystal planes on which to make measurements, extent of masking needed to identify a suitable sampling volume, type of detector and alignment ...
The Micro-strip Metal Foil Detectors (MMFD) designed and used for the Beam Profile Monitoring (BPM) are discussed. The results obtained for the MMFDs produced by different technologies are presented. The MMFD deposited onto the 20 {mu}m thick Si-wafer has been used for the BPM of the 32 MeV alpha-particle beam at the MPIfK (Heidelberg) Tandem generator. Another MMFD with totally removed Si-wafer at the working area has been applied for the on-line X-ray BPM at the HASYLAB (DESY). One may conclude that the developed technology of the micro-strip metal detector manufacturing allows to provide non-destructive measurement of X-ray intensity distribution over area of up to 50 mm{sup 2} with an accuracy of 10-20 {mu}m with a possibility of its improvement by a factor 5. A sub-micron position resolution is expected by applying electron lithography for the strip pattern production.
An x-ray fluorescence spectrometer was designed and fabricated which nondestructively determines the thickness of aluminum cladding at small suspected thin spots in the inner or outer surface of actinide reactor tubes. The analysis method is based on the difference in absorption of actinide L/sub #alpha#/ and L/sub #beta#/ fluorescent x-rays in passing through the cladding. Calibration plots of the logarithm of the L/sub #beta#//L/sub #alpha#/ x-ray intensity ratio versus cladding thickness are linear to at least 40 mils for U-Al, U_3O_8-Al, and PuO_2-Al substrates. Accuracy and precision of the experimentally determined cladding thickness and evaluated for both uranium and plutonium substrates. Experimental thickness data are reported for 618 quality assurance analyses on six Mark 41 PuO_2-Al target tubes. An x-ray fluorescence cladding thickness monitor operated with a computer-controlled fluoroscope holds considerable promise for quality assurance because (1) a ...
In the execution of disposal of low and intermediate level radioactive wastes, it is important to evaluate accurately the kind and quantity of each radionuclide in the wastes. For such an evaluation, correlation of non-gamma-emitting nuclides based on gamma-emitting nuclides is recommended and regarded as a partial method. This method necessitates a completion of a highly accurate and reliable nondestructive assay system of gamma-emitting nuclides for partical use. In 1992, in support of the new waste disposal program in Hungary, Paks NPP initiated a waste characterization program to determine the radiological properties of its rad wastes. A segmented gamma scanning system has been set up to measure the gamma-emitting nuclides in 2000 litre low level drums following in-drum compaction. In the framework of the program a radiochemical analysis sub-program was stated to determine the long-lived non-gamma emitting radionuclides, mainly those listed in US regulatory ...
A knowledge of surface film growth kinetics can be quite useful in the production of materials for uses ranging from protective coatings to microelectronic devices. A technique for determining the kinetics of film growth is presented which should prove to be a valuable alternative to the array of spectroscopies (AES, RBS, etc.) currently favored for these measurements. Some of the virtues of this X-ray diffraction approach are its non-destructive nature, thickness resolution better than 50 {angstrom} and conventional equipment requirements. Results obtained for the growth of Pd{sub 2}Si films during thermal annealing of Pd coatings on Si, indicate parabolic growth over a temperature range of 160-222 C. The rate constant was found to be k{prime} = 7 {times} 10{sup {minus}4} exp ({minus}1.06 eV/kT) cm{sup 2}/sec, where (film thickness){sup 2} = k{prime} x time. This activation energy is in agreement with results obtained by other techniques. A comparison of this ...
This research focuses on the development and application of high order statistical analyses applied to measurements performed with subcritical fissile systems driven by an introduced neutron source. The signatures presented are derived from counting statistics of the introduced source and radiation detectors that observe the response of the fissile system. It is demonstrated that successively higher order counting statistics possess progressively higher sensitivity to reactivity. Consequently, these signatures are more sensitive to changes in the composition, fissile mass, and configuration of the fissile assembly. Furthermore, it is shown that these techniques are capable of distinguishing the response of the fissile system to the introduced source from its response to any internal or inherent sources. This ability combined with the enhanced sensitivity of higher order signatures indicates that these techniques will be of significant utility in a variety of applications. Potential ...
Neutron radiography has been put to practical use in foreign countries as one of nondestructive inspection technologies, but in Japan, its application to other scientific fields is mainly researched. The reason is, the neutron radiography apparatuses installed in Japan are hard to be industrially utilized for a number of reasons, but also the characteristics of neutron radiography are not clearly established, and it is not standardized. The part from a collimator through an object to a detector is called ``upstream``, the part of an image detector is called ``midstream``, and the part of image processing is called ``downstream``. The nonparallel property of beam, image distortion and the lack of sharpness, beam quality and the interaction of neutron beam with an object are discussed about the upstream. The intensity of neutron beam, the energy spectra, the effective total macroscopic cross section, the effective energy, the evaluation of scattered beam and ...
During the present study concentration of nine elements (K, Ca, Mn, Fe, Cu, Zn, Se, Br and Pb) in different tissues of mud crab Scylla serrata from Mahanadi estuary, India were determined by the external PIXE set up at Institute of Physics, Bhubaneswar, India. The study demonstrates the effectiveness of the technique in analyzing both soft and hard tissue samples from marine organisms and opens the door for non-destructive, multi-elemental analysis of tissue samples with a very little sample preparation by direct irradiation. This technique can be well utilized for analyzing the tissue samples for environmental, toxicological and nutritional purposes. The study also demonstrates the elemental concentrations from tissue samples of any crustaceans from Mahanadi estuary for the first time. Sex based difference in the elemental concentration of the mud crabs were marked, which may be related to the growth rate and other biological activities. No significant difference ...
After October 1993, Swedish BWR power plant operators will be required to present an inspection concept which will facilitate the nondestructive examination of recirculation system piping. According to the pertinent Swedish codes and standards, such inspections will be required to focus on internal pipe surfaces. Since it is impossible for external inspections to cover all essential areas with the necessary degree of sensitivity (geometry, beam attenuation), Siemens-KWU was commissioned to develop an inspection system which combines ultrasonic search units and eddy current probes to produce the required degree of examination sensitivity. A pipe crawler was developed to transport the inspection unit. This device can be used for the inspection of circumferential and longitudinal pipe welds, nozzle-to-pipe welds and RPV nozzle-to-shell welds. Special probes designed to fulfill inspection and manipulation requirements were developed for the inspection of the 30 welds ...
CEA-Valduc produces some radioactive waste (mainly alpha emitters). Legislation requires producers to sort their waste by activity and type of isotopes, and to package them in order to forward them to the appropriate reprocessing or storage facility. Our lab LMDE (laboratory for measurements on nuclear wastes and valuation) is in charge of the characterization of the majority of waste produced by CEA-Valduc. Among non-destructive methods to characterize a radioactive object, gamma-spectroscopy is one of the most efficient. We present to this conference the method we use to characterize nuclear waste and the system we developed to characterize our germanium detectors. The goal of this system is to obtain reliable numerical models of our detectors and calculate their efficiency curves. Measurements are necessary to checks models and improve them. These measurements are made on a bench using pinpoint sources ("1"3"3Ba, "1"5"2Eu) from 60 keV to 1500 keV, with distances ...
As part of the Nondestructive Evaluation Reliability Program sponsored by the US Nuclear Regulatory Commission, the Pacific Northwest Laboratory is developing a method that uses risk-based approaches to establish in-service inspection plans for nuclear power plant components. This method uses probabilistic risk assessment (PRA) results and Failure Modes and Effects Analysis (FEMA) techniques to identify and prioritize the most risk-important systems and components for inspection. The Surry Nuclear Power Station Unit 1 was selected for pilot applications of this method. The specific systems addressed in this report are the reactor pressure vessel, the reactor coolant, the low-pressure injection, and the auxiliary feedwater. The results provide a risk-based ranking of components within these systems and relate the target risk to target failure probability values for individual components. These results will be used to guide the development of improved inspection ...
The author describes the results of post-test analyses of PANDA transient (M-series) tests M2 and M3. The purpose of the PANDA post-test analysis activity is to demonstrate that TRACG is applicable for the calculation of long-term SBWR containment response to a LOCA. Comparisons between TRACG predictions and test measurements are presented and discussed in the dual context of what the test results show and the capability of TRACG to predict their key features
The results of tests performed on the FMC Fresnel-Belt Solar Collector at the Midtemperature Solar Systems Test Facility are summarized. Tests were conducted over a temperature range from 100 to 250/sup 0/C. Test objectives are defined, test procedures are described, and test results and conclusions are given.
Two accelerated aging test procedures are proposed for use on solid dielectric extruded distribution cables under wet conditions. One test method is a fixed time duration test in which the degree of cable specimen aging is assessed in terms of breakdown tests, while the other test method is a time to breakdown test in which the cable specimens are voltage stressed until failure ensues.
The foils of various materials were irradiated with "6"0Co with an activity of 11,538 TBq. The minimum radiation dose was 25 kGy. Changes in chemico-physical properties were evaluated by infrared spectroscopy and were not detected after irradiation with 25 kGy. Packing foils were subjected to the following tests: mechanical tests, tests of weld strength, tests of impact resistance, free fall tests, permeability tests for water vapour and microbiological tests. The results of all tests were tabulated. The tests showed that the foils are impermeable for microorganisms and provided the welds are airtight the packed products remain sterile. (J.P.).
Performance testing and ...Performance testing and commissioning In either an Authority-owned or a dedicated MRF, the Contracting Authority should ...Performance testing is done to demonstrate that the contractor is able to meet the guarantees given
Task, Psychomotor Vigilance Test (PVT) Transition to Operations ... Related Tasks (36). Task, Psychomotor Vigilance Test (PVT) on ISS. Common Item(s) ...
... Construction, Geology, and Aquifer Testing of the Maalo ... 8-98) Prescribed by ANSI Std Z39-18 Page 3. Construction, Geology, and Aquifer Testing ...
Two hazard risk assessment matrices for the ranking of occupational health risks are described. The qualitative matrix uses qualitative measures of probability and consequence to determine risk assessment codes for hazard-disease combinations. A walk-through survey of an underground metalliferous mine and concentrator is used to demonstrate how the qualitative matrix can be applied to determine priorities for the control of occupational health hazards. The semi-quantitative matrix uses attributable risk as a quantitative measure of probability and uses qualitative measures of consequence. A practical application of this matrix is the determination of occupational health priorities using existing epidemiological studies. Calculated attributable risks from epidemiological studies of hazard-disease combinations in mining and minerals processing are used as examples. These historic response data do not reflect the risks associated with current ...
Quantitative bone scans were evaluated in 16 patients with osteoporosis and in a control group of 7 healthy subjects. Along with a detailed biochemical analysis of calcium-phosphorus metabolism and standartized reongenographs, a quantitative dynamic bone scintigraphy was performed according to the method proposed by the authors. The bone-accumulating factor K_b was determined on the base of mathematical analysis of the graph reflecting activity changes in bone tissue unit during the investigation, the blood-elimination factor K_h and kidney-elimination factor K_k. In addition the accumulation index AI (in %) was calculated as a relation between the activity in bone tissue unit, registered in 20 min interval, and the activity in soft tissues for the same time. Whereas the static gamma camera scintigraphy, made 3-4 hrs after injecting of the osteotrope radiopharmaceuticals, showed no specific changes in the patients examined, the method proposed ...
The effect of various forms of treatment of renal osteodystrophy was evaluated in 25 dialysis patients by quantitative bone scintigraphy, using 99m-Tc-HEDP. The results were compared with those of biochemical and bone morphometric studies. The total skeletal activity (TSA) decreased in 5 patients after transplantation, in 11 after parathyroidectomy and in 6 out of 9 treated conservatively, but did not normalize in any of the patients. Bone morphometric evaluation of treatment, which could be performed in 19 of the 20 patients who did not receive a transplant, demonstrated a reduction in the degree of hyperparathyroidism in 17 patients (89 percent). Osteoid excess was reduced in 13 patients (68 percent) but an evident reduction of osteomalacic osteoid, i.e. improvement of osteomalacia, occurred in only 4 patients (21 percent). Changes in the TSA correlated significantly with the changes in the biochemical and histological parameters of hyperparathyroidism, but not ...
The effect of various forms of treatment of renal osteodystrophy was evaluated in 25 dialysis patients by quantitative bone scintigraphy, using 99m-Tc-HEDP. The results were compared with those of biochemical and bone morphometric studies. The total skeletal activity (TSA) decreased in 5 patients after transplantation, in 11 after parathyroidectomy and in 6 out of 9 treated conservatively, but did not normalize in any of the patients. Bone morphometric evaluation of treatment, which could be performed in 19 of the 20 patients who did not receive a transplant, demonstrated a reduction in the degree of hyperparathyroidism in 17 patients (89 per cent). Osteoid excess was reduced in 13 patients (68 per cent) but an evident reduction of osteomalacic osteoid, i.e. improvement of osteomalacia, occurred in only 4 patients (21 per cent). Changes in the TSA correlated significantly with the changes in the biochemical and histological parameters of hyperparathyroidism, but ...
The diffusion of ion beam injected self-interstitials (I) and their interaction with impurities in crystalline Si has been investigated and modeled. In particular, the I-substitutional carbon (C) interactions have been studied, using a molecular-beam-epitaxy grown Si{sub 1-y}C{sub y} layer interposed between the shallow I-source and a deeper B-spike (marker for I-concentration). Substitutional C atoms are shown to trap I's, to be removed from their substitutional sites, and to form stable precipitates into the C-rich region. The I-trapping mechanism was quantitatively studied by a simulation code. The reactions causing trapping and deactivation are described. In addition, the boron markers approach was extended to the two dimensional (2D) diffusion. High resolution scanning capacitance microscopy was used for quantitative measurements of the 2D boron transient enhanced diffusion induced on a boron delta array by the I's ion ...
The diffusion of ion beam injected self-interstitials (I) and their interaction with impurities in crystalline Si has been investigated and modeled. In particular, the I-substitutional carbon (C) interactions have been studied, using a molecular-beam-epitaxy grown Si_1_-_yC_y layer interposed between the shallow I-source and a deeper B-spike (marker for I-concentration). Substitutional C atoms are shown to trap I's, to be removed from their substitutional sites, and to form stable precipitates into the C-rich region. The I-trapping mechanism was quantitatively studied by a simulation code. The reactions causing trapping and deactivation are described. In addition, the boron markers approach was extended to the two dimensional (2D) diffusion. High resolution scanning capacitance microscopy was used for quantitative measurements of the 2D boron transient enhanced diffusion induced on a boron delta array by the I's ion beam injected through a ...
In 576 patients quantitative scintigraphy of the sacroiliac joints and the spinal cord with "9"9"mTc-pyrophosphate was performed. 328 were patients with proven ankylosing spondylitis according to the New York criteria. 120 were patients with a clinically and roentgenologically suspected ankylosing spondylitis and 128 persons formed a healthy control group. The count rate in small regions of interest (ROI) in the sacroiliac joints, the spinal cord and the os sacrum were compared on the basis of indexes. The scintigraphic data of patients with ankylosing spondylitis were compared with the healthy control group and with the radiographic findings and radiologic staging of the disease. In a longitudinal follow-up study during 1 to 6 years these investigations were continued together with clinical and roentgenological checks. Quantitative bone scintigraphy provides characteristic indexes for ankylosing spondylitis, indicating the increased mineral ...
In 620 patients quantitative bone scintigraphy with "9"9"mTc pyrophosphate of the sacroiliac joints and of the spine was performed: 365 patients with confirmed ankylosing spondylitis, 125 patients with clinical radiological suspicion for ankylosing spondylitis (probable Bechterev) and control group of 130 healthy individuals. By comparison of the activity in zones of interest of the sacroiliac joints, the spine and sacrum, the following indices were determined: sacroiliac (separately for the left and right sacroiliac joints), index D_1_0/sacrum, index L_4/sacrum and index C_7/sacrum. The scintigraphic finding was compared to the X-ray one and to the radiological stage of the disease. A long-term follow-up of the patients was carried out during 1-6 years with scintigraphic, X-ray and clinical investigations. Emphasis was laid upon the posibilities for quantitative scintigraphy for early diagnostics of ankylosing spondylitis. The combination of ...
Quantitative hepatic scintiangiography was previously used for evaluating the relative contribution of hepatic arterial and portal venous blood flows to the hepatic circulation. The present study compares 3 different procedures (automatic and manual integration, and slope fitting methods) for analyzing the hepatic time activity curves obtained after bolus i.v. injection of 370 MBq /sup 99m/Tc-diethylentriaminopentacetic acid. Twenty five subjects were studied: Five controls, ten cirrhotics, and ten portal hypertensive patients previously submitted to side to side portacaval anastomosis. The correspondence between results given by the different methods was satisfactory only in shunted patients, and the reproducibility of computed parameters was quite poor for all procedures. Accordingly, none of the methods can be considered as supporting reliable quantitative pathophysiological evaluations. However, the hepatic arterial/portal venous flow ratio ...
Purpose: Cardiomyopathy is one of the major complications of {beta} thalassaemia major as a result of transfusion iron overload. The aim of our study is to evaluate with MR if there is any difference of iron deposition signal intensity (SI) or distribution between non-cardiopatic and cardiopatic thalassaemic patients in order to establish if there is a relationship between cardiopathy and iron deposition. Materials and methods: We studied 20 patients affected by {beta} thalassaemia major, of whom 10 cardiopatic and 10 non-cardiopatic, and 10 healthy volunteers as control group. Serum ferritin and left ventricular ejection fraction were calculated in thalassaemic patients. All patients were examinated using a 1.5 MR unit with ECG-gated GE cine-MR T2*-weighted, SE T1-weighted and GE T2*-weighted sequences. In all cases, using an adequate ROI, the myocardial and skeletal muscle signal intensity (SI), the myocardial/skeletal muscle signal intensity radio (SIR) and the SI average of the ...
Iodized oil has been used as a contrast agent in lymphangiography. One of the commercially available compounds is Lipidol Ultra-fluid(LUF) which contains 38% iodine by weight. Nakakuma et al(1979) reported that LUF was selectively retained in the hypervascular hepatocellular carcinoma when injected directly into the ligated hepatic artery. Since that time, it has been widely utilized in the detection as well as the therapeutic attempts of hepatocellular carcinoma, where it has been mixed with chemotherapeutic agents or labeled with radioactive I-131. Like all significant advances, the mechanism of lipid retention within the hepatocellular carcinoma is not clearly understood, and also there is a lack of information about the biodistribution and kinetics of I-131 Lipiodol. The apparent safety of this technique require confirmation. The present study was aimed to assess the biodistribution and kinetics of intraarterially injected I-131 Lipiodol and the histologic changes in canine livers. ...
This report describes the results made in fulfillment of contract DE-FG26-02NT15451, ''Multicomponent Seismic Analysis and Calibration to Improve Recovery from Algal Mounds: Application to the Roadrunner/Towaoc Area of the Paradox Basin, Ute Mountain Ute Reservation, Colorado''. Optimizing development of highly heterogeneous reservoirs where porosity and permeability vary in unpredictable ways due to facies variations can be challenging. An important example of this is in the algal mounds of the Lower and Upper Ismay reservoirs of the Paradox Basin in Utah and Colorado. It is nearly impossible to develop a forward predictive model to delineate regions of better reservoir development, and so enhanced recovery processes must be selected and designed based upon data that can quantitatively or qualitatively distinguish regions of good or bad reservoir permeability and porosity between existing well control. Recent advances in seismic ...
Full text: A semiempirical algorithm for absorbed dose calculation at off-axis points in irregular beams was implemented. It is well known that semiempirical methods are very useful because of their easy implementation and its helpfulness in dose calculation in the clinic. These methods can be used as independent tools for dosimetric calculation in many applications of quality assurance. However, the applicability of such methods has some limitations, even in homogeneous media, specially at off axis points, near beam fringes or outside the beam. Only methods derived from tissue-air-ratio (TAR) or scatter-maximum-ratio (SMR) have been devised for those situations, many years ago. Despite there have been improvements for these manual methods, like the Sc-Sp ones, no attempt has been made to extend their usage at off axis points. In this work, a semiempirical formalism was introduced, based on the works of Venselaar et al. (1999) and Sanz et al. (2004), aimed to the Sc-Sp separation. This ...
This report describes work carried out in the context of TurboTech Interim for the development of a system for monitoring stationary gas turbines for approaching the stability limit of the compressor. The requirements for the system components were defined and the suitability of different types and positions of pressure sensors were examined and evaluated. It was found very early in the work that, due to the complexity of the object being monitored, one would not succeed in finding a simple criterion for monitoring the pump limit. Rather, apart from the selection of suitable sensors and optimum positions, one must analyse the present signals in different ways and create a decision matrix from this. Existing work on this subject is mostly concerned with the phenomena in the context of experiments on experimental compressors or is not suitable for the requirements of stationary industrial gas turbines. The project is being carried out in the context of TurboTech II with the main aims of: ...
In order to understand not only the mechanisms of earthquakes, but also the origin of diverse behavior of faults and plate boundaries, one must integrate (1) field studies on faults to understand deep intrafault processes, (2) laboratory work to reproduce those processes and determine mechanical and transport properties of fault zones, (3) theoretical and numerical studies analyzing fault motion, including earthquake generation processes, based on the constitutive properties determined by laboratory studies, and (4) seismological and geodetic studies revealing dynamic fault motion during earthquakes and diverse aseismic fault behavior. Ideally, such integrated studies should be carried out for a selected fault that produced an earthquake with good seismic/geodetic records so the prediction from (1) to (3) can be fully tested with (4), rather than selecting favorite data in the literature. Present session is organized to promote such integrated fault and earthquake ...
We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.
Methods for the synthesis and quantitation of the novel choline analogues, telluronium choline and acetyltelluronium choline, are described. An assay procedure utilizing pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS) with cold trapping was developed with [2H4]telluronium choline and [2H4]acetyltelluronium choline as internal standards. The telluronium compounds were ion-pair extracted from tissue with dipicrylamine, washed with 2-butanone, and pyrolyzed prior to GC-MS analysis. The compounds were monitored using selected ion monitoring at m/z 232 and m/z 190 for acetyltelluronium and telluronium choline, respectively, and at m/z 236 and m/z 194 for the analogous deuterated internal standards. The assay was linear over a range of 20 pmol-20 nmol of compound taken through the assay. PMID:8130881
Sustainable development of geothermal resources is the key to prolong the commercial life of geothermal fields. This paper uses two well-known geothermal fields in China, with long histories of production, to demonstrate how sustainability can be quantitatively evaluated, and to highlight the essential differences between sustainable and non-sustainable development schemes. After examining the complex nature of sustainability evaluation, fuzzy synthetic evaluation is applied as a tool for the quantitative sustainability rating of geothermal reservoirs. The evaluation procedures include systemic criteria selection, weighing, individual criterion evaluation and finally final multi-criterion decision analysis evaluation. The sustainability of a limestone reservoir in the urban sector of Tianj...
Quantitative determination of Broensted acid site concentrations in calcined H-mordenite and H-ZSM-5 by means of conductometric titration and infrared spectroscopy reveals that the concentration of Broensted acid sites present is lower than would be expected on the basis of the aluminum content. This discrepancy is attributed to dealumination and dehydroxylation processes occurring during calcination. A model is proposed according to which the degree of these processes strongly depends on the concentration of vicinal aluminum T sites in the zeolite: Broensted acid sites associated with these T sites are lost, and the remaining Broensted acidity is related to the concentration of the (remaining) isolated aluminum T sites. This model quantitatively correlates the experimentally determined concentration of Broensted acid sites with the concentration of isolated aluminum T sites. 33 refs., 4 figs., 2 tabs.
The Structural Aging (SAG) Program is carried out by the Oak Ridge National Laboratory (ORNL) under sponsorship of the United States Nuclear Regulatory Commission (USNRC). The Program has evolved from preliminary studies conducted to evaluate the long-term environmental challenges to light-water reactor safety-related concrete civil structures. An important conclusion of these studies was that a damage methodology, which can provide a quantitative measure of a concrete structure's durability with respect to potential future requirements, needs to be developed. Under the SAG Program, this issue is being addressed through: establishment of a structural materials information center, evaluation of structural component assessment and repair technologies, and development of a quantitative methodology for structural aging determinations. Progress to date of each of these activities is presented as well as future plans. 7 refs., 5 figs.
In situ X-Ray microtomography offers new opportunities for analysing sintering mechanisms since it allows 3D observation of the microstructural evolution of the powder all along a sintering cycle. With synchrotron radiation at ESRF, a 3D image with a resolution of 2 {mu}m can be obtained in about one minute. In addition to the visual examination of the images, relevant microstructural parameters can be measured through quantitative image analysis using recently developed tools. In this paper the results obtained with two materials, loose copper powder and compacted steel powder, are resumed. For copper powder, the dispersion of local parameters such as particle co-ordination number and porosity is investigated. Concerning steel compacts, data about pore morphology evolution and on local strains provides clues for understanding the anisotropic shrinkage of such compacts. (authors)
A Quantitative Computed Tomography (QCT) method, simplifying the well-known technique proposed by Genant (1982) and applied to a standard third generation whole body CT scanner is described. This technique was applied in the measurement of the trabecular bone which has high sensitivity for metabolic changes. The BMC (Bone Mineral Content) measured in different groups of subjects (healthy postmenopausal patients versus women with postmenopausal osteoporosis) showed a highly significant difference (p<0.001). The precision of repositioning (coefficient of variation 1.8% to 2.3%, obtained in healty male patients) and the good, linear relationship computed from the phantom values, minimize measurement errors. Since this method is quickly applied and involves low-dose radiation-exposure, it could be introduced in the clinical study of metabolic bone diseases.
We summarize recent developments in x-ray microscopy of polymers by focusing on the characterization of organic electronic devices. The quantitative compositions of model polymer blends have been mapped at a resolution of {approx}35 nm. Since it could be inferred that these devices have structures smaller than 35 nm, quantitative compositional mapping at length scales below the present resolution limit of x-ray microscopy is required. Organic devices thus serve to both highlight the success of NEXAFS microscopy to date, but to also outline the very real need for higher spatial resolution. New approaches to create improved optics or different acquisition modalities are required if x-ray microscopy is to make sustained contributions to such an important area of research as organic devices.
In this paper, a robust water level control system for the horizontal steam generator (SG) using the quantitative feedback theory (QFT) method is presented. To design a robust QFT controller for the nonlinear uncertain SG, control oriented linear models are identified. Then, the nonlinear system is modeled as an uncertain linear time invariant (LTI) system. The robust designed controller is applied to the nonlinear plant model. This nonlinear model is based on a locally linear neuro-fuzzy (LLNF) model. This model is trained using the locally linear model tree (LOLIMOT) algorithm. Finally, simulation results are employed to show the effectiveness of the designed QFT level controller. It is shown that it will ensure the entire designer's water level closed loop specifications.
In the process of backward Raman amplification (BRA), the leading layers of the seed laser pulse can shadow the rear layers, thus weakening the effective seeding power and affecting parameters of output pulses in BRA. We study this effect numerically and also analytically by approximating the pumped pulse by the ''*-pulse'' manifold of self-similar solutions. We determine how the pumped pulse projection moves within the *-pulse manifold, and describe quantitatively the effective seeding power evolution. Our results extend the quantitative theory of BRA to regimes where the effective seeding power varies substantially during the amplification. These results might be of broader interest, since the basic equations, are general equations for resonant 3-wave interactions.
To define the quantitative and qualitative effects of gossypol (GP) on deer (Cervus elaphus) semen, the animals were fed cottonseed (CS). Adult stags each received 350?g of CS for 109?days. Animals received 15?mg of gossypol per kilogram body weight per day. Quantitative and qualitative parameters of experimental ejaculates (n?=?182) were compared to ejaculates (n?=?571) of control animals (n?=?5) collected during three previous natural reproductive seasons. Ejaculate fractions were evaluated by classical methods used in domestic animals. In this paper, we show that mature male deer fed CS exhibited morphological changes and decreased motility of spermatozoa and abnormalities in spermatogenesis. Radioimmunoassay measured concentrations of various steroid hormones (T-testosterone, A4-andros...
We discuss some methods to quantitatively investigate the properties of correlation matrices. Correlation matrices play an important role in portfolio optimization and in several other quantitative descriptions of asset price dynamics in financial markets. Specifically, we discuss how to define and obtain hierarchical trees, correlation based trees and networks from a correlation matrix. The hierarchical clustering and other procedures performed on the correlation matrix to detect statistically reliable aspects of the correlation matrix are seen as filtering procedures of the correlation matrix. We also discuss a method to associate a hierarchically nested factor model to a hierarchical tree obtained from a correlation matrix. The information retained in filtering procedures and its stability with respect to statistical fluctuations is quantified by using the Kullback-Leibler distance.
Mechanobiological theories have been introduced to illustrate the interaction between biology and the local mechanical environment during bone healing. Although several theories have been proposed, a quantitative validation using histomorphometric data is still missing. In this study, in vivo histological data based on an ovine animal experiment was quantified and used to validate bone healing simulations focussing on the endochondral ossification process. The bone formation at different callus regions (periosteal and endosteal bone at the medial and lateral side) was analyzed from in vivo data and quantitatively compared with in silico results. A histomorphometric difference was found in medial and lateral hard callus formation 3 weeks after osteotomy. However, the same amount of new bone...
The author presents a detailed and quantitative description of all of the programs, systems, sensors and experiments associated with the next 30 years of space endeavors by the National Aeronautics and Space Administration. Derived from the fifth issue of the NASA Space Systems Technology Model, the missions and payloads are categorized by applications area: solar system exploration, astrophysics, earth sciences, communications, space transportation and utilization of the space environment. Far-term missions are described as opportunity missions and landmark missions, for the distant future. Technology requirements are collected by discipline: power, propulsion, materials, structures, information systems, navigation, guidance and control. Payload technology requirements are organized by instrument sensing range. This information defines in quantitative terms, the opportunities and limits for future civilian space system capabilities.
Calcaneus quantitative ultrasound (QUS) assessment is a safe and reliable method for evaluating skeletal status. Until now, considerable data have been accumulated on the distribution of QUS in Caucasian populations, whereas such data are still insufficient in Asian populations, especially in Chinese mainland. The present study aimed to obtain the distribution characteristic of calcaneus QUS in healthy Chinese women, and to further investigate the distribution of low bone mass by QUS stiffness index (SI). This study included 2,498 healthy Chinese females aged 10-87 yr. The QUS exhibited a characteristic mild rise and then fall pattern with increasing age. Age, body height, and weight were significant influencing factors on SI, especially age and weight. The prevalence of osteoporosis detec...
We have recently introduced several important improvements in the measurement of distillation curves for complex fluids. The modifications include a composition-explicit data channel for each distillate fraction (for both qualitative and quantitative analysis) and corrosivity assessment of each distillate fraction. The composition-explicit information is achieved with a new sampling approach that allows precise qualitative as well as quantitative analyses of each fraction, on the fly. We have applied the new method to a variety of fluids, including simple n-alkanes, rocket propellant, gasoline, jet fuels, and a hydrocarbon fluid made corrosive with dissolved hydrogen sulfide. In the current contribution, we present the application of the advanced distillation curve method to two samples of...
Ab initio lattice dynamics based on linear response method are performed for high pressure phase of yttrium to describe electron-phonon coupling and subsequent superconducting behavior. The critical temperature Tc in fcc-Y increases monotonically with pressure up to 9.25 K at 31 GPa, which is quantitatively in excellent agreement with two quasihydrostatic experiments and is qualitatively compatible with recent experiments. The excellent agreement with experiments gives us a better understanding of the effective pseudopotential ?* as well as spectral function ?2(?)F(?) in yttrium. These results demonstrate that there exists strong electron-phonon coupling in Y within the studied pressure regime, and for lower pressure electron correlation becomes stronger. Generally, it is found that superconductivity in yttrium under pressure can be described quantitatively within standard theory of phonon-mediated superconductivity.
Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experi...
Nowadays there are many sun-protection cosmetics incorporating organic or inorganic UV filters as active ingredients. Chemically stable inorganic sunscreen agents, usually metal oxides, are widely employed in high-SPF (sun protection factor) products. Titanium dioxide is one of the most frequently used inorganic UV filters. It has been used as a pigment for a long period of cosmetic history. With the development of micronization techniques, it has become possible to incorporate titanium dioxide in sunscreen formulations without the previous whitening effect, and hence its use in cosmetics has become an important research topic. However, there are very few works related to quantitation of titanium dioxide in sunscreen products. In this research, we analysed the amounts of titanium dioxide i...
This paper describes a radiation shield verification survey of a large hot cell at the Fast Flux Test Facility (FFTF). The following aspects of the shield test are discussed: description of the FFTF; description of the hot cell; the test procedures; radiation protection, and the test results.
The object of the test was to develop a method to field test the Exploding Bridgewire (EBW) System for proper functioning prior to use. Two basic designs were conceived and tested. The first design using a two element spark gap and a calibrated fuse link ...
IntroductionChest pain with ST-segment elevation is a rare clinical problem during dobutamine stress testing. Although beta-agonists treatment prior to dobutamine stress testing...Full Text Available
... Search Help? Coping with Test Pain, Discomfort, and Anxiety Introduction | Be Prepared | Know Your Tests | Relax | Conclusion ... though they may feel some embarrassment, discomfort, or anxiety at the outset. If undergoing medical tests makes ...
This Test Plan outlines the testing to be done on the Special Protective Coating (SPC) Polyurea which includes: Tank Waste Compatibility, Decontamination Factor Testing, and Adhesion Strength Testing after a sample has been exposed to Radiation.
... Risk (Adverse) for Endangered Species: Risk to aquatic species if anticipated pesticide residue levels equal one-fifth of LD10 or one-tenth of LC50; risk to ...terrestrial species if anticipated pesticide residue levels equal one-fifth of LC10 or one-tenth of LC50. Risk Assessment: Qualitative and quantitative evaluation of the ... Risk for Non-Endangered Species: Risk to species if anticipated pesticide residue levels are equal to or greater than LC50. Risk Management: The process ...
Grain yield is a major goal for the improvement of durum wheat, particularly in drought-prone areas. In this study, the genetic basis of grain yield (GY), heading date (HD), and plant height (PH) was...Full Text Available
We compute the potential for localized closed string tachyons in bosonic string theory on the orbifold C/Z{sub 4} using level-truncated closed string field theory. The critical points of the potential exhibit features which agree with their conjectured identification as lower-order orbifolds. However this case also raises some questions regarding the quantitative predictions associated with these conjectures. (author)
Based on a literature study an actual summary of the risk-utility problems in X-ray diagnosis is outlined due to the Recommendations of the International Commission for Radiation Protection (ICRP publication 26/1977). Papers demonstrating quantitative assessment of the somatic and genetical risk in X-ray examination are preferably cited and evaluated. It is concluded that the somatic and genetical risk is low in diagnostic ratiology. However, it must not be neglected and has always to be compared to the utility of an examination as well as to other risks of the examination. (author).
DescriptionRemote sensing of the sea surface from satellites in near-polar orbits has contributed greatly to our understanding of the links between physical and biological processes in marine systems. However most of this progress has been made in open oceanic waters or major upwelling areas, and many unresolved problems are encountered in coastal regions and shelf seas. In these optically complex waters, quantitative remote sensing requires a more sophisticated interpretation strategy than that implemente [continued...