WorldWideScience
1

High-Sensitivity Analysis of Naturally Occurring Sugar Chains, Using a Novel Fluorescent Linker Molecule  

UK PubMed Central (United Kingdom)

To analyse the binding of sugar chains to proteins, viruses and cells, the surface plasmon resonance (SPR) technique is very convenient and effective because it is a real-time, non-destructive detection...Full Text Available

2009-07-01

2

2. Nuclear analytical methods and environmental protection  

International Nuclear Information System (INIS)

The first step in the protection of the environment is the control of pollutant level in the components of the environment. The application is compared of radionuclide X-ray fluorescence analysis (RXFA) used for this purpose with polarographic and nuclear analytical techniques. The advantage of RXFA is its high sensitivity and selectivity, its low time and cost exactingness. The origins and development of RXFA are described. (Ha).

1983-12-01

3

Immunological detection and quantification of DNA components structurally modified by alkylating carcinogens, mutagens and chemotherapeutic agents  

International Nuclear Information System (INIS)

The detection and quantification of defined reaction products of chemical mutagens and carcinogens (and of many cancer chemotherapeutic agents) with DNA require highly sensitive analytical techniques. The exceptional capability of immunoglobulins to recognize subtle alterations of molecular structure (especially when monoclonal antibodies are used to maximize specificity), outstanding sensitivity of immunoanalysis by high-affinity antibodies, and the fact that radioactively-labelled agents are not required suggest the utility of a radioimmunoassay to recognize and quantitate alkylated DNA products. We have recently developed a set of high-affinity monoclonal antibodies (secreted by mouse x mouse as well as by rat x rat hybridomas; antibody affinity constants, 10"9 to > 10"1"0 lmol) specifically directed against several DNA alkylation products with possible relevance in relation to both mutagenesis and malignant ...

1983-09-01

4

A dual-emissive-materials design concept enables tumour hypoxia imaging  

British Library Electronic Table of Contents (United Kingdom)

Luminescent materials are widely used for imaging and sensing owing to their high sensitivity, rapid response and facile detection by many optical technologies. Typically materials must be chemically tailored to achieve intense, photostable fluorescence, oxygen-sensitive phosphorescence or dual emission for ratiometric sensing, often by blending two dyes in a matrix. Dual-emissive materials combining all of these features in one easily tunable molecular platform are desirable, but when fluorescence and phosphorescence originate from the same dye, it can be challenging to vary relative fluorescence/phosphorescence intensities for practical sensing applications. Heavy-atom substitution alone increases phosphorescence by a given, not variable amount. Here, we report a strategy for modulating ...

2009-01-01

5

Development of time-resolved laser fluorescence spectrometry for on-line uranium checking in solutions of the Purex reprocessing process; Developpement de la spectrofluorimetrie laser a resolution temporelle pour le controle en ligne de l`uranium dans les solutions du procede de retraitement purex  

Energy Technology Data Exchange (ETDEWEB)

The Purex process and the fluorescence spectrometry are first recalled, then uranyl fluorescence is studied in a pure nitric medium without other elements to establish a theoretical model, allowing the description of uranium fluorescence signal with a general equation. The influence of different parameters (temperature, inhibitors, dynamic quenching of iron and cerium) is investigated to develop the model. A quantitative analysis method without addition of reagents is proposed to validate the model.

1992-02-25

6

Probing the Mechanisms of an Air Amplifier using a LTQ-FT-ICR-MS and Fluorescence Spectroscopy  

UK PubMed Central (United Kingdom)

We report the first quantitative assessment of electrosprayed droplet/ion focusing enabled by the use of a voltage-assisted air amplifier between an electrospray ionization emitter and a hybrid...Full Text Available

2007-11-01

7

X-ray fluorescence analysis as auxiliary method of restorers  

International Nuclear Information System (INIS)

The principle is described of X-ray fluorescence analysis and the manner of detecting the emitted characteristic radiation. The advantages are presented of radionuclide X-ray fluorescence analysis which consist primarily in the possibility of conducting a totally non-destructive analysis, and of accurate and relatively narrow localization of the analyzed area, the simultaneous qualitative and quantitative determinations of a large number of elements in the order of concentrations 10"1 to 10"-"4%, stability of excitation radiation flux, simple design and relatively low capital costs. The so-called matrix effect is pointed to. A number of examples is given of the use of the cited method, including its use in the analysis of art objects. (J.B.).

1987-09-07

8

Determination of Mn, Fe, Ni, Cu, Zn and Pb contents in samples of apple trees by radionuclide X-ray fluorescence analysis  

Energy Technology Data Exchange (ETDEWEB)

The applicability of the radionuclide X-ray fluorescence analysis (RXFA) for qualitative and quantitative evaluation of environmental plant samples is discussed and examples of determination of Mn, Fe, Ni, Cu, Zn, Pb in samples of apple trees are given. The instrumentation, the standard and sample preparation are also presented.

1982-12-01

9

Groundtruth approach to accurate quantitation of fluorescence microarrays  

Energy Technology Data Exchange (ETDEWEB)

To more accurately measure fluorescent signals from microarrays, we calibrated our acquisition and analysis systems by using groundtruth samples comprised of known quantities of red and green gene-specific DNA probes hybridized to cDNA targets. We imaged the slides with a full-field, white light CCD imager and analyzed them with our custom analysis software. Here we compare, for multiple genes, results obtained with and without preprocessing (alignment, color crosstalk compensation, dark field subtraction, and integration time). We also evaluate the accuracy of various image processing and analysis techniques (background subtraction, segmentation, quantitation and normalization). This methodology calibrates and validates our system for accurate quantitative measurement of microarrays. Specifically, we show that preprocessing the images produces results significantly closer to the known ground-truth for these samples.

2000-12-01

10

Quantitative non-destructive evaluation of high-temperature superconducting materials  

Energy Technology Data Exchange (ETDEWEB)

Even though the currently intensive research efforts on high- temperature superconducting materials have not yet converged on a well specified practical material, the indications are that such a material may be quite brittle, anisotropic, and may contain many flaws such as microcracks and voids at grain boundaries. Consequently, practical applications of high temperature superconducting materials will require a very careful strength analysis based on fracture mechanics considerations. Because of the high sensitivity of the strength of such materials to the presence of defects, methods of quantitative non-destructive evaluation may be expected to play an important role in strength determinations. This proposal is concerned with the use of ultrasonic methods to detect and characterize isolated cracks, clusters of microcracks and microcracks distributed throughout the material. Particular attention has been, and will continue ...

1991-06-14

11

Quantitative Computed Tomography (QCT) of vertebral spongiosa. Evaluation of a possible method for managment of postmenopausal osteoporosis (PMO)  

International Nuclear Information System (INIS)

A Quantitative Computed Tomography (QCT) method, simplifying the well-known technique proposed by Genant (1982) and applied to a standard third generation whole body CT scanner is described. This technique was applied in the measurement of the trabecular bone which has high sensitivity for metabolic changes. The BMC (Bone Mineral Content) measured in different groups of subjects (healthy postmenopausal patients versus women with postmenopausal osteoporosis) showed a highly significant difference (p<0.001). The precision of repositioning (coefficient of variation 1.8% to 2.3%, obtained in healty male patients) and the good, linear relationship computed from the phantom values, minimize measurement errors. Since this method is quickly applied and involves low-dose radiation-exposure, it could be introduced in the clinical study of metabolic bone diseases.

1987-01-01

12

A radionuclide analyzer of total sulfur in coal  

International Nuclear Information System (INIS)

The devised radionuclide analyzer for the determination of total sulfur in coal includes two radionuclide sources with different energies, which are accommodated in collimators fitted with adjustable diaphramgs. The sample compartment is located between the two sources. Moreover, an X-ray fluorescence standard can be slid into the sample compartment. A proportional detector for X-ray fluorescence and scattered gamma radiation is located off the sample compartment. The input of the proportional detector is interfaced to the output of a high-voltage supply, the output, to the information input of a control-and-evaluation unit. One of the control outputs of the control-and-evaluation unit is connected to the input of the sliding mechanism for the X-ray fluorescence standard. This arrangement enables automatic energy calibration of the analyzer. The analyzer can measure not only total sulfur in coal by radionuclide X-ray ...

1987-05-13

13

X-ray spectral microanalysis of component redistribution in finely dispersed two-phase alloys  

International Nuclear Information System (INIS)

It is shown that it is necessary to take into account locality of the analysis and to introduce additional corrections for partial capture of matrix and fluorescent subexcitation by matrix during quantitative X-ray spectral microanalysis of finely dispersed materials. Cast two-phase (#alpha#+#beta#) titanium alloy VT3-1 is chosen as an investigation object.

14

The VOISE Algorithm: a Versatile Tool for Automatic Segmentation of Astronomical Images  

CERN Document Server

The auroras on Jupiter and Saturn can be studied with a high sensitivity and resolution by the Hubble Space Telescope (HST) ultraviolet (UV) and far-ultraviolet (FUV) Space Telescope spectrograph (STIS) and Advanced Camera for Surveys (ACS) instruments. We present results of automatic detection and segmentation of Jupiter's auroral emissions as observed by HST ACS instrument with VOronoi Image SEgmentation (VOISE). VOISE is a dynamic algorithm for partitioning the underlying pixel grid of an image into regions according to a prescribed homogeneity criterion. The algorithm consists of an iterative procedure that dynamically constructs a tessellation of the image plane based on a Voronoi Diagram, until the intensity of the underlying image within each region is classified as homogeneous. The computed tessellations allow the extraction of quantitative information about the auroral features such as mean intensity, latitudinal ...

2009-01-01

15

Depth profile analysis on the nanometer scale by a combination of electron probe microanalysis (EPMA) and focused ion beam specimen preparation (FIB)  

International Nuclear Information System (INIS)

Electron probe microanalysis (EPMA) offers high sensitivity and high accuracy in quantitative measurements of chemical compositions and mass coverages. Owing to the low detection limits of the wavelength-dispersive technique, monolayers with mass coverages of about 0.05 pg cm z can be detected. Assuming a density of 5 g cm--3 this corresponds to a thickness of 0.1 nm. With these advantages in mind, EPMA was extended to depth profile analysis in the sub-micron range using a surface removal technique. The present paper shows how depth profile analysis can be improved by combining EPMA and the focused ion beam (FIB) technique. The focused ion beam system uses a Ga+ ion beam. The ion beam allows the milling of defined geometries on the nanometer scale, so that very shallow bevels with exactly defined angles in relation to the surface can be obtained. Low surface damage is expected due to low sputtering effects. Calibrated WDX ...

16

Instruments for X-ray fluorescence analysis and spectrometry  

International Nuclear Information System (INIS)

The radionuclide X-ray fluorescence analyzer consists of a source changer and a sample changer. "5"5Fe, "1"0"9Cd and "2"4"1Am are used as excitation sources. The radiation is detected with a semiconductor Si(Li) detector. The complete assembly of the apparatus consists of an imagine unit, a keyboard, a floppy disc drive, a printer, a console and a rack with analog and digital electronics. Its multichannel amplitude analyzer consists of power supplies, a high voltage supply, a linear amplifier, an analog-to-digital converter and a computer. The technical specifications are given. The control and data processing system is controlled with an MHB 8080A microprocessor. Software for semiconductor gamma spectrometry and for quantitative gamma spectrometry will be supplied with the equipment. (E.S.). 3 figs., 4 refs.

17

Radioanalytical methods of rare earth element determination  

International Nuclear Information System (INIS)

Instrumental neutron activation analysis (INAA) and radionuclide X-ray fluorescence analysis (RXFA) were used for the determination of rare earth elements. For INAA, solution obtained by sample decomposition was dripped onto filter paper, enclosed and sealed into a polyethylene foil. The sample was activated in reactor WWR-S over a period of 4 to 6 hours with a neutron fluence of 10"1"3cm"-"2. Gamma radiation measurement was carried out with a planar and a coaxial HP-Ge detector in three decay periods. La, Ce, Nd, Sm, Eu, Gd, Tb, Ho, Tm, Yb and Lu were determined. The advantage of the method is its accuracy and high sensitivity, the disadvantage is the time-consuming analysis. The RXFA method was used as a rapid and operative method for the analysis of loose ore samples, aqueous and organic solutions of rare earth elements. For exciting X-ray radiation, "2"4"1Am was used and the radiation of K-lines was detected with a ...

1989-06-01

18

High sensitivity detection and characterization of the chemical state of trace element contamination on silicon wafers  

CERN Document Server

Increasing the speed and complexity of semiconductor integrated circuits requires advanced processes that put extreme constraints on the level of metal contamination allowed on the surfaces of silicon wafers. Such contamination degrades the performance of the ultrathin SiO sub 2 gate dielectrics that form the heart of the individual transistors. Ultimately, reliability and yield are reduced to levels that must be improved before new processes can be put into production. It should be noted that much of this metal contamination occurs during the wet chemical etching and rinsing steps required for the manufacture of integrated circuits and industry is actively developing new processes that have already brought the metal contamination to levels beyond the measurement capabilities of conventional analytical techniques. The measurement of these extremely low contamination levels has required the use of synchrotron radiation total reflection X-ray fluorescence (SR-TXRF) ...

2003-01-01

19

Enzyme-linked immunosorbent assays for alpha-synuclein with species and multimeric state specificities.  

Science.gov (United States)

Abnormal intracellular deposition of aggregated ?-synuclein is the characteristic feature of a number of neurological disorders, including Parkinson's disease (PD). Although ?-synuclein is typically known as a cytosolic protein, a small amount is secreted by exocytosis in both monomeric and aggregated forms. The extracellular forms of ?-synuclein in human body fluids, such as cerebrospinal fluid (CSF) and blood plasma, might be a diagnostic target for PD and related diseases. Here, we characterized a new set of monoclonal antibodies against ?-synuclein, and using different combinations of antibodies, we established ELISA systems to specifically detect human ?-synuclein, mouse and human ?-synuclein together, and multimeric forms of ?-synuclein in biological samples. By employing the Tyramide signal amplification method, the sensitivity of the assay was significantly improved to detect a concentration as low as ?12.5 pg/ml. These assays might be useful tools for ...

2011-05-31

20

Ultrasensitive fluorescence detection of DNA  

Science.gov (United States)

Progress on Ultrasensitive fluorescence detection of DNA is briefly described. (CBS)

1991-01-01

21

Radionuclide X-ray fluorescence analysis. 3: Examples of application in practice  

Science.gov (United States)

Examples are given of the applicability and importance of radionuclide fluorescence analysis as a

1973-01-01

22

Fluorescent Silicate Materials for the Detection of Paraoxon  

Science.gov (United States)

... significantly lower limits of detection. The complex fluorescence spectra of these constructs indicated that only a portion ...

2010-03-19

23

ASE FILE  

Science.gov (United States)

radionuclide X-ray fluorescence analysis: the resolving power of the ... The radiation detectors used in radionuclide X-ray fluorescence ...

24

Rapid laser fluorometric method for the determination of uranium in soil, ultrabasic rock, plant ash, coal fly ash and red mud samples  

International Nuclear Information System (INIS)

A simple and rapid laser fluorometric determination of trace and ultra trace level of uranium in a wide variety of low uranium content materials like soil, basic and ultra basic rocks, plant ash, coal fly ash and red mud samples is described. Interference studies of some common major, minor and trace elements likely to be present in different geological materials on uranium fluorescence are studied using different fluorescence enhancing reagents like sodium pyrophosphate, orthophosphoric acid, penta sodium tri-polyphosphate and sodium hexametaphosphate. The accurate determination of very low uranium content samples which are rich in iron, manganese and calcium, is possible only after the selective separation of uranium. Conditions suitable for the quantitative single step extraction of 25 ng to 20 #mu#g uranium with tri-n-octylphosphine oxide and single step quantitative stripping with dilute neutral ...

1999-10-01

25

Low grade inflammation, as evidenced by basal high sensitivity CRP, is not correlated to outcome measures in IVF  

UK PubMed Central (United Kingdom)

PurposeTo assess the relationship between low-grade inflammation, measured as basal high sensitivity (hs)-CRP, and IVF outcome.MethodsWe recruited...Full Text Available

2008-08-01

26

Radiation methods in research of ancient monuments  

Energy Technology Data Exchange (ETDEWEB)

A 'Laboratory of Quantitative Methods in Monument Research' is being built at the CTU Prague. Its primary orientation is the investigation of historic architecture, although other objects of art can also be investigated. In the first phase, two radiation methods are being established, but it is set up in such a way, that various other methods can readily be added in its future development. The radiation methods chosen for the initial development of the laboratory are: thermoluminescence dating and X-ray fluorescence analysis. The design of the automated TL-reader, built in our laboratories, is adjusted for the purpose of dating of historic brick architecture (which, of course, does not exclude applications for ceramics and other materials). The investigation of renaissance architecture in southern Bohemia and Moravia is under preparation as the first large campaign of this kind in the Czech Republic. Radionuclide X-ray ...

2000-11-15

27

Radiation methods in research of ancient monuments  

International Nuclear Information System (INIS)

A 'Laboratory of Quantitative Methods in Monument Research' is being built at the CTU Prague. Its primary orientation is the investigation of historic architecture, although other objects of art can also be investigated. In the first phase, two radiation methods are being established, but it is set up in such a way, that various other methods can readily be added in its future development. The radiation methods chosen for the initial development of the laboratory are: thermoluminescence dating and X-ray fluorescence analysis. The design of the automated TL-reader, built in our laboratories, is adjusted for the purpose of dating of historic brick architecture (which, of course, does not exclude applications for ceramics and other materials). The investigation of renaissance architecture in southern Bohemia and Moravia is under preparation as the first large campaign of this kind in the Czech Republic. Radionuclide X-ray ...

2000-11-15

28

Quantitation of Cellular Dynamics in Growing Arabidopsis Roots with Light Sheet Microscopy  

CERN Document Server

To understand dynamic developmental processes, living tissues must be imaged frequently and for extended periods of time. Root development is extensively studied at cellular resolution to understand basic mechanisms underlying pattern formation and maintenance in plants. Unfortunately, ensuring continuous specimen access, while preserving physiological conditions and preventing photo-damage, poses major barriers to measurements of cellular dynamics in indeterminately growing organs such as plant roots. We present a system that integrates optical sectioning through light sheet fluorescence microscopy with hydroponic culture that enables us to image at cellular resolution a vertically growing Arabidopsis root every few minutes and for several consecutive days. We describe novel automated routines to track the root tip as it grows, track cellular nuclei and identify cell divisions. We demonstrate the system's capabilities by collecting data on divisions and nuclear ...

2011-01-01

29

Follow-up of pregnant women exposed to chicken pox: an audit of relationship between level of antibody and development of chicken pox  

British Library Electronic Table of Contents (United Kingdom)

The purpose of this study was to validate through natural exposure a cut-off level of varicella zoster IgG as protective against infection with varicella zoster virus (VZV). Laboratory testing to determine VZV immune status of pregnant women exposed to varicella is recommended. Quantitative assays are now available which are sensitive and specific. More than 200 consecutive requests for screening in pregnant patients with recent varicella contacts were followed-up by questionnaire. DiaSorin LIAISON and VZV time resolved fluorescence immuno assay (VZV TRFIA) were used to measure VZV antibody level. One hundred fifty out of 209 (72%) questionnaires were returned; 14 patients developed varicella, 129 did not and seven were not known. Patients who had been given VZIG and developed varicella on...

2011-01-01

30

Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation  

Science.gov (United States)

This investigation describes the technique for the detection of the X-ray fluorescent radiation

1972-01-01

31

Silencing of SARS-CoV spike gene by small interfering RNA in HEK 293T cells  

International Nuclear Information System (INIS)

Two candidate small interfering RNAs (siRNAs) corresponding to severe acute respiratory syndrome-associated coronavirus (SARS-CoV) spike gene were designed and in vitro transcribed to explore the possibility of silencing SARS-CoV S gene. The plasmid pEGFP-optS, which contains the codon-optimized SARS-CoV S gene and expresses spike-EGFP fusion protein (S-EGFP) as silencing target and expressing reporter, was transfected with siRNAs into HEK 293T cells. At various time points of posttransfection, the levels of S-EGFP expression and amounts of spike mRNA transcript were detected by fluorescence microscopy, flow cytometry, Western blot, and real-time quantitative PCR, respectively. The results showed that the cells transfected with pEGFP-optS expressed S-EGFP fusion protein at a higher level compared with those transfected with pEGFP-S, which contains wildtype SARS-CoV spike gene sequence. The green fluorescence, mean ...

2004-11-26

32

Determination of Cinchona alkaloids and Vitamin B_6 by high-performance liquid chromatography with fluorescence detection  

International Nuclear Information System (INIS)

A simple and specific method has been developed for the simultaneous determination of the four major Cinchona alkaloids and their dihydroderivatives and pyridoxine hydrochloride (Vitamin B_6) by high-performance liquid chromatography (HPLC) with fluorescence detection (#lambda#_e_m=420 nm with #lambda#_e_x=330 nm). The chromatographic separation was performed on a Phenomenex Prodigy ODS column (5 #mu#m, 250 mmx3.2 mm i.d.), recommended for basic compounds, under isocratic reversed-phase conditions. The method allowed a good peak shape and an effective resolution of the tested compounds. The extraction of alkaloids from the Cinchona succirubra bark was carried out in mild and fast conditions (ambient temperature, 20 min) by ultrasonication. The procedure showed to be advantageous respect to a reference method, which involved Soxhlet extraction. The results were compared statistically by means of the Student's t-test and the variance ratio F-test; no significant ...

2004-06-04

34

The fluorescence properties and NMR analysis of protopine and allocryptopine  

International Nuclear Information System (INIS)

The fluorescence properties of protopine and allocryptopine in aqueous and organic environments are described for the first time. The fluorescence of alkaloids and their pH-dependent interconversion to cationic forms (transannular interaction) were studied using steady-state and time-resolved fluorescence techniques. For the analysis of tricyclic base and cis/trans tetracyclic cations of the alkaloids, NMR and X-ray crystallography were used. - Highlights: ? We describe fundamental fluorescence characteristics of alkaloids protopine and allocryptopine. ? We analyzed the pH-dependent transitions and cis/trans isomerization. ? These two alkaloids can be better distinguished by their fluorescence decay characteristics. ? The fluorescence parameters are related to the NMR and crystallographic structural data.

2011-07-01

36

Valence electronic structure of Ni in Ni-Si alloys from relative K X-ray intensity studies  

Energy Technology Data Exchange (ETDEWEB)

The K{beta}-to-K{alpha} X-ray intensity ratio of Ni in Ni{sub 3}Si, Ni{sub 2}Si and NiSi has been determined by energy dispersive X-ray fluorescence technique. It is found that the intensity ratio of Ni decreases from pure Ni to Ni{sub 2}Si and then increases from Ni{sub 2}Si to NiSi, in good agreement with the electronic structure calculations cited in the literature. We have also performed band structure calculations for pure Ni in various atomic configurations by means of linear muffin-tin orbital method and used this data with the normalized theoretical intensity ratios cited in the literature to estimate the 3d-occupation numbers of Ni in Ni-Si alloys. It is emphasized that investigation of alloying effect in terms of X-ray intensity ratios should be carried out for the stoichiometric alloys in order to make reliable and quantitative comparisons between theory and experiment in transition metal alloys.

2007-02-15

37

Noninvasive analysis of skin iron and zinc levels in beta-thalassemia major and intermedia  

Energy Technology Data Exchange (ETDEWEB)

Diagnostic x-ray spectrometry, a method based on x-ray fluorescence analysis, was used for noninvasive determination of iron and zinc in two distinct skin areas, representing predominantly dermal and epidermal tissues, in 56 patients with beta-thalassemia major and intermedia. The mean iron levels in the skin of patients with beta-thalassemia major and intermedia were elevated by greater than 200% and greater than 50%, respectively, compared with control values. The zinc levels of both skin areas examined were within the normal range. The data indicate that the rate and number of blood transfusions, which correlated well with serum ferritin levels (r . 0.8), are not the only factors that determine the amount of iron deposition in the skin (r less than 0.6). Other sources of iron intake contribute to the total iron load in the tissues, particularly in patients who are not given multiple transfusions. The noninvasive quantitation of skin levels ...

1985-01-01

38

Interaction of bovine serum albumin with some novel PEG-containing diblock copolymers  

British Library Electronic Table of Contents (United Kingdom)

A comparative study on the interaction of different PEG-containing diblock copolymers including SA400, SA600, SA1500 and OA1500 (stearyl and oleyl esters of polyethylene glycol with 400, 600 and 1500 molecular weights, respectively) with bovine serum albumin (BSA) was carried out using isothermal titration calorimetry (ITC), attenuated total reflectance Fourier transform infrared (ATR-FTIR), circular dichroism (CD), and fluorescence spectroscopies. ITC data show that SA400, SA600, SA1500 and OA1500 bind to BSA, with association constants of (14.5, 3.16, 50.7 and 17.6)x103M-1, respectively. Results also show that the binding is enthalpically driven, disfavored by conformational entropy. Quantitative analysis of the FTIR absorbance spectra at amide Iprime (1600-1700cm-1) as well as far UV ci...

2008-01-01

39

Detection and Analysis of Tumor Fluorescence Using a Two-Photon Optical Fiber Probe  

UK PubMed Central (United Kingdom)

The utility of a two-photon optical fiber fluorescence probe (TPOFF) for sensing and quantifying tumor fluorescent signals was tested in vivo. Xenograft tumors were developed in athymic mice using MCA207...Full Text Available

2004-06-01

40

x - NASA Technical Reports Server  

Science.gov (United States)

Mar 1, 2011 ... Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation ...

41

Radionuclide X-ray fluorescence analysis. 1: Excitation of X-ray fluorescense radiation by nuclear radiation  

Science.gov (United States)

The principles of radionuclide excitation of X-ray fluorescence radiation and its application in

1972-01-01

42

Observation of Fluorescence for some lanthanides in LiCl-KCl molten salt media at high temperature  

Energy Technology Data Exchange (ETDEWEB)

To our knowledge, the fluorescence studies of lanthanides in LiCl-KCl eutectic molten salt at a high temperature are not reported yet. The fluorescence of the lanthanide-ions was generally decreased when the temperature was increased. Moreover, the fluorescence of the lanthanides was strong when the sample was solidified to or from the melt. The temperature, where the fluorescence was decreased, was identified to be different depending on the species of the lanthanides and the substrates was considered to possibly be from quenching of the fluorescence due to either the collisions of melted samples induced by high temperature media or the re-absorption of fluorescence by the samples. Several comparison experiments were performed to explain and understand this phenomenon and improve the fluorescence. In this way, an on-line monitoring of ...

2008-08-15

43

NASA Technical Reports Server - Radionuclide X-ray fluorescence ...  

Science.gov (United States)

Aug 1, 1972 ... The principles of radionuclide excitation of X-ray fluorescence radiation and its application in analytic chemistry are discussed.

45

A high sensitivity two-color interferometer for pulsed power plasmas  

International Nuclear Information System (INIS)

A high sensitivity, high bandwidth, two-color interferometer (1064 and 532 nm) has been tested on the Hawk pulsed power generator at the Naval Research Laboratory. The phase resolution is 10"-"5 waves with a rise time of 3 ns, a new capability for diagnosing plasmas, and neutrals in pulsed power experiments. The two-color feature is used to distinguish phase shifts from free (plasma) electrons and bound (neutral and ion) electrons. Simultaneous electron and neutral density measurements were demonstrated in a plasma opening switch (POS) experiment. The ability to measure small phase shifts with fast rise time were demonstrated in a plasma filled diode experiment. The high sensitivity and vibration isolation enable neutral gas distribution measurements from supersonic nozzles used in plasma radiation source experiments. Examples of these measurements and future applications are described. copyright 1997 ...

49

Radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Slovak 1973. 164 p. Czechoslovakia Havranek, E. Bumbalova, A. Svitel,

1973-01-01

50

Preparation and Characterization of Fe3O4/CdTe Magnetic/Fluorescent Nanocomposites and their Applications in Immuno-labeling and Fluorescent Imaging of Cancer Cells  

UK PubMed Central (United Kingdom)

The synthesis of a new kind of magnetic, fluorescent multifunctional nanoparticles (~30 nm in diameter) was demonstrated, where multiple fluorescent CdTe quantum dots (QDs) are covalently linked...Full Text Available

2010-01-19

51

NONDESTRUCTIVE DETERMINATION OF AIRBORNE LEAD ...  

Science.gov (United States)

... NONDESTRUCTIVE DETERMINATION OF AIRBORNE LEAD PARTICULATES BY THE RADIONUCLIDE X-RAY FLUORESCENCE ANALYSIS. ...

53

Lidar techniques for search and rescue  

Energy Technology Data Exchange (ETDEWEB)

Four techniques for using LIDAR in Search and Rescue Operations will be discussed. The topic will include laser retroreflection, laser-induced fluorescence in the visible, laser-induced fluorescence during daylight hours, and laser-induced fluorescence in the uv. These techniques use high-repetition rate lasers at a variety of frequencies to induce either fluorescence in dye markers or retroreflection from plastic corner cubes on life preservers and other emergency markers.

1985-01-01

58

Retrieval of chlorophyll a concentration from a fluorescence enveloped area using hyperspectral data  

British Library Electronic Table of Contents (United Kingdom)

It is acknowledged that fluorescence line height (FLH) algorithms are still hampered by the uncertainty of fluorescence peak position. The fluorescence peak moves to longer wavelengths with the increase of chlorophyll a concentration. In this article, the fluorescence enveloped area (FEA), which integrates the fluorescence height and the fluorescence peak position, was used to estimate the chlorophyll a concentration in the coastal waters of the Pearl River Estuary. The FEA algorithm was developed from in situ data of chlorophyll a concentration, total suspended matter (TSM) concentration and above-water remote sensing reflectance, which were collected at 37 sampling stations in the Pearl River Estuary during two cruises. The results showed that the FEA algorithm made a better estimation o...

2011-01-01

59

Quantitation of Antibiotics by High-Pressure Liquid Chromatography: Cephalothin  

UK PubMed Central (United Kingdom)

A technique for quantitative determination of cephalothin and desacetylcephalothin in serum using a method based on high-pressure liquid chromatography is described. Both compounds were quantitatively...Full Text Available

1978-02-01

60

Human papillomavirus infection and anal carcinoma. Retrospective analysis by in situ hybridization and the polymerase chain reaction.  

UK PubMed Central (United Kingdom)

To examine the association of human papillomavirus (HPV) infection with anal squamous cell carcinoma, the authors applied the highly sensitive polymerase chain reaction (PCR) and in situ hybridization...Full Text Available

1992-06-01

61

Cluster analysis of behavioural and event-related potentials during a contingent negative variation paradigm in remitting-relapsing and benign forms of multiple sclerosis  

UK PubMed Central (United Kingdom)

BackgroundEvent-related potentials (ERPs) may be used as a highly sensitive way of detecting subtle degrees of cognitive dysfunction. On the other hand, impairment of cognitive skills...Full Text Available

62

A spectrophotometric method for the direct determination of cysteine in the presence of other naturally occurring amino acids  

UK PubMed Central (United Kingdom)

1. An acid ninhydrin reagent was found to react specifically in forming a pink product (Emax. 560mμ) with cysteine. 2. The method was highly sensitive for the determination...Full Text Available

1967-08-01

63

A Simple, Versatile and Sensitive Cell-Based Assay for Prions from Various Species  

UK PubMed Central (United Kingdom)

Detection and quantification of prion infectivity is a crucial step for various fundamental and applied aspects of prion research. Identification of cell lines highly sensitive to prion infection led...Full Text Available

64

Radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The author's achievements in the title field are summarized and discussed. The following topics are dealt with: (i) principles of radionuclide X-ray fluorescence analysis; (ii) mathematical methods in X-ray fluorescence analysis; (iii) Ross differential filters; (iv) application of radionuclide X-ray fluorescence analysis in the coal industry (with emphasis on the determination of the ash content, sulfur content, and arsenic content of coal); and (v) evaluation of the X-ray fluorescence analyzer from the radiological safety point of view. (P.A.).

1994-01-01

65

Analytic description of X-ray fluorescence intensity as a function of the particle size in powder samples and pulp upon X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Analytic expression is derived for X-ray fluorescence dependence on the particle size of powder and slurry media. The expression is obtained for a model of powder medium containing particles of different size and random distribution in the bulk of the sample. Limiting cases of homogeneous and slurry-like media are considered and expressions for calculation of the fluorescence intensity are derived. The results reasonably match the experiment for binary powder mixtures and thus provide evaluation of the powder particle size on the fluorescence intensity for multicomponent polydisperse powder medium

2007-11-01

66

Intrinsic fluorescence of the amniotic fluid  

International Nuclear Information System (INIS)

The intrinsic fluorescence of clear amniotic fluid from third-trimester pregnancy is reported. The fluorescence intensity peaked at 405 nm when excited by ultraviolet light in the range of 310 to 360 nm. All of the 33 samples tested fluoresced, and their emission spectrum had the same shape, varying only in magnitude. Changing sample temperature (20 to 50 C) and sample pH (7.2 to 7.7) had little effect on the emission spectrum. The same fluorescence, with higher intensity, was observed when some newborn urine was tested. The fluorescence of amniotic fluid may provide a new tool to determine fetal age, fetal organ maturation, and fetal distress. (author).

1981-01-01

67

The efflux of a fluorescent probe is catalyzed by an ATP-driven extrusion system in Lactococcus lactis.  

UK PubMed Central (United Kingdom)

Many bacteria, both gram positive and gram negative, extrude in an energy-dependent manner the fluorescent pH indicator 2',7'-bis-(2-carboxyethyl)-5[and -6]-carboxyfluorescein (BCECF) (D. Molenaar,...Full Text Available

1992-05-01

68

Six orders of magnitude dynamic range in capillary electrophoresis with ultrasensitive laser-induced fluorescence detection  

UK PubMed Central (United Kingdom)

An ultrasensitive laser-induced fluorescence detector was used with capillary electrophoresis for the study of 5-carboxy-tetramethylrhodamine. The raw signal from the detector provided roughly...Full Text Available

2009-12-15

69

Real-Time Assessment of Cardiac Perfusion, Coronary Angiography, and Acute Intravascular Thrombi Using Dual-Channel Near-Infrared Fluorescence Imaging  

UK PubMed Central (United Kingdom)

ObjectivesWe have developed an image-guided surgery system based on invisible near-infrared (NIR) fluorescent light. Presently, the only clinically-available NIR...Full Text Available

2009-07-01

70

Rate of allosteric change in hemoglobin measured by modulated excitation using fluorescence detection.  

UK PubMed Central (United Kingdom)

We have measured the forward and reverse rates of the allosteric transition of hemoglobin A with three CO molecules bound by using modulated excitation coupled with fluorescence quenching of the DPG...Full Text Available

1989-10-01

71

Radionuclide X-ray fluorescence analysis of waste water from the production of citric acid  

Energy Technology Data Exchange (ETDEWEB)

Radionuclide X-ray fluorescence analysis was used for the determination of iron, calcium, potassium, copper, manganese and zinc in waste water from the production process of citric acid.

1982-02-18

72

Radionuclide X-ray fluorescence analysis of waste water from the production of citric acid  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis was used for the determination of iron, calcium, potassium, copper, manganese and zinc in waste water from the production process of citric acid. (author).

1982-02-01

73

Photophysics and optical switching in green fluorescent protein mutants  

UK PubMed Central (United Kingdom)

We demonstrate by using low-temperature high-resolution spectroscopy that red-shifted mutants of green fluorescent protein are photo-interconverted among three conformations and are, therefore, not...Full Text Available

2000-03-28

74

Near Infrared-Fluorescent and Magnetic Resonance Imaging Molecular Probe with High T1 Relaxivity for In Vivo Multimodal Imaging  

UK PubMed Central (United Kingdom)

A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.

2010-06-07

75

Improved DNA Sequencing Accuracy and Detection of Heterozygous Alleles Using Manganese Citrate and Different Fluorescent Dye Terminators  

UK PubMed Central (United Kingdom)

The use of dideoxynucleotide triphosphates labeled with different fluorescent dyes (dye terminators) is the most versatile method for automated DNA sequencing. However, variation in peak heights reduces...Full Text Available

1999-06-01

76

Electron Transport-Dependent Chlorophyll-a Fluorescence Quenching by O2 in Various Algae and Higher Plants  

UK PubMed Central (United Kingdom)

A comparison of chlorophyll-a fluorescence in brown algae (Macrocystis integrifolia, Fucus vesiculosis), green algae (Scenedesmus obliquus, Ulva sp.)...Full Text Available

1983-12-01

77

Early Detection of Bronchial Lesions Using Lung Imaging Fluorescence Endoscope  

UK PubMed Central (United Kingdom)

The performance of the Lung Imaging Fluorescence Endoscope (LIFE) system was compared with conventional bronchoscopy in 158 patients: 68 patients with invasive cancer, 42 patients with abnormal sputum...Full Text Available

1999-01-01

78

Coupling of Pressure-Induced Structural Shifts to Spectral Changes in a Yellow Fluorescent Protein  

UK PubMed Central (United Kingdom)

AbstractX-ray diffraction analysis of pressure-induced structural changes in the Aequorea yellow fluorescent protein Citrine reveals the structural basis for the continuous...Full Text Available

2009-09-16

79

Contribution to the radionuclide x-ray fluorescence analysis of human blood and plasma  

International Nuclear Information System (INIS)

A photon-induced x-ray fluorescence method allowing the simultaneous determination of iron, copper, zinc, bromine and rubidium in human blood and blood plasma samples is described. The method is reliable and has a good sensitivity for a wide range of elements. (author).

1986-04-01

80

Binding of a Fluorescent Lipid Amphiphile to Albumin and its Transfer to Lipid Bilayer Membranes  

UK PubMed Central (United Kingdom)

Kinetics and thermodynamics of the binding of a fluorescent lipid amphiphile, Rhodamine Green™-tetradecylamide (RG-C14:0), to bovine serum albumin were characterized in an equilibrium...Full Text Available

2003-01-01

81

A novel fluorescent pH probe for expression in plants  

UK PubMed Central (United Kingdom)

BackgroundThe pH is an important parameter controlling many metabolic and signalling pathways in living cells. Recombinant fluorescent pH indicators (pHluorins) have come into vogue...Full Text Available

82

8. Application of radionuclide X-ray fluorescence analysis in other fields of science and technology  

International Nuclear Information System (INIS)

Certain applications are described of radionuclide X-ray fluorescence analysis in the ore dressing industry, in the manufacture of building materials, in metallurgy, pharmacy, in the chemical, photographic and paper industries, in space exploration, in archeology and for measuring the thicknesses of thin layers of coatings. (ES).

1983-12-01

83

In vitro H2AX phosphorylation and micronuclei induction in human fibroblasts across the Bragg curve of a 577MeV/nucleon Fe incident beam  

Energy Technology Data Exchange (ETDEWEB)

The space environment consists of a varying field of radiation particles including high-energy ions, with spacecraft shielding material providing the only major protection to astronauts from harmful exposure. Unlike low-linear energy transfer (LET) {gamma} or X-rays, the presence of shielding does not always reduce the radiation risks for energetic charged particle exposure, since the dose delivered by the charged particle increases sharply as the particle approaches the end of its range, a position known as the Bragg peak. The Bragg curve does not necessarily represent the biological damage along the particle traversal, and the 'biological Bragg curve' is dependent on the energy and the type of the primary particle, and may vary for different biological endpoints. Here we used a unique irradiation geometry to measure the biological response across the Bragg curve in human fibroblasts exposed to 577MeV/nucleon incident Fe ions in vitro. Polyethylene shielding was used ...

2006-10-15

84

Final report of the second dye-tracer test at the Chestnut Ridge Security Pits, Y-12 Plant, Oak Ridge, Tennessee  

Energy Technology Data Exchange (ETDEWEB)

Martin Marietta Energy Systems, Inc. (Energy Systems) manages a closed hazardous waste disposal unit, Chestnut Ridge Security Pits (CRSP), in the form of two trenches and several auger-holes, located on top of the eastern portion of Chestnut Ridge at the Department of Energy (DOE) Oak Ridge Y-12 Plant in Tennessee. The groundwater monitoring system for the unit presently consists of a network of upgradient and downgradient monitor wells. To investigate the discharge of groundwater to springs and streams. An initial dye-tracer study was conducted during the driest part of 1990. The dye was detected at some of the monitoring sites, but verification was necessary due to the proximity of some sites to extraneous dye sources. A second dye-tracer was conducted during the wet weather season. The actual test commenced during the first week of February 1992 with a 4-week baseline monitoring period to determine the inherent variability of the emission spectra within the wavelength range ...

1992-11-01

85

Synthesis of histidine-stabilized cadmium sulfide quantum dots: Study of their fluorescence behaviour in the presence of adenine and guanine  

British Library Electronic Table of Contents (United Kingdom)

Cadmium sulfide particles have been synthesized in the aqueous medium using the amino acid histidine as a stabilizing agent. These particles demonstrate the phenomenon of size quantization effect. The fluorescence of histidine-stabilized CdS was found to be enhanced and quenched by the addition of DNA bases adenine and guanine, respectively. The fluorescence enhancement of CdS in the presence of adenine has been explained on the basis of interaction between the quantum dot stabilizer and the amino group of adenine. Quenching of CdS fluorescence by guanine occurs due to interaction of the substrate with the quantum dot surface.

2010-01-01

86

Radionuclide X-ray fluorescence analysis using semiconductor detectors  

International Nuclear Information System (INIS)

Czech May 1979. p. 32-33. Czechoslovakia Benada, J. Spacek, B. Ustav

1979-05-01

87
88

Microcomputers in radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Czech Apr 1986. p. 51. Czechoslovakia Cechak, T. Kluson, J. Ceske

1986-04-01

89

Ion Transport Measurements in a Multi-Dipole Argon Plasma by Broadband Laser Induced Fluorescence  

International Nuclear Information System (INIS)

Argon ion laser induced fluorescence measurements were carried out in a multipolar filament discharge with a broadband diode laser centered on 668 nm, which stimulated a transition from the metastable state in Ar(II) 3d4F7/2 to 4p4D05/2. The intensity of the induced fluorescence at 442 nm was maximized by the optimization of the discharge parameters and the laser power. From the recovery of the background fluorescence after the laser was turned off, the ion diffusion coefficient was deduced and compared with the result inferred from the experiments of ion acoustic wave (IAW) damping.

2009-06-01

90

Determination of ash content in coal by means of backscattered X-ray radiation and X-ray fluorescence analysis, and devices manufactured by the PAR company  

Energy Technology Data Exchange (ETDEWEB)

Discusses methods for determining ash content in coal using backscattering in X-ray fluorescence. The following aspects are evaluated: principle of ash content determination, energy sources, factors that influence measurement accuracy, reliability. Types of X-ray fluorescence analyzers developed in Czechoslovakia and manufactured in the Czech Republic are comparatively evaluated. Operation of the RPM 113.1 radionuclide X-ray fluorescence analyzer developed by the PAR company and used for measuring ash content in coal and coal calorific value is discussed. 7 refs.

1993-09-01

91

3. Physical foundations and methodology of radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The physical foundations are described of radionuclide X-ray fluorescence analysis (RXFA) and the table shows the values of K- and L-absorption thresholds and the K- and L-line energies of elements. The calculation of the intensity of characteristic radiation during RXFA proceeds from relations derived for conventional X-ray fluorescence analysis. The choice of the radionuclide source is ruled by the nature of the analysed substance and the used detection technique. The diagram shows the areas of radionuclide sources and the energy of the fluorescence radiation of elements. The table shows the spectra of radionuclide sources suitable for the purposes of RXFA measured by semiconductor Si(Li) and Ge(Li) detectors. (ES).

1983-12-01

92

NOx Sensor Development  

Energy Technology Data Exchange (ETDEWEB)

NO{sub x} compounds, specifically NO and NO{sub 2}, are pollutants and potent greenhouse gases. Compact and inexpensive NO{sub x} sensors are necessary in the next generation of diesel (CIDI) automobiles to meet government emission requirements and enable the more rapid introduction of more efficient, higher fuel economy CIDI vehicles. Because the need for a NO{sub x} sensor is recent and the performance requirements are extremely challenging, most are still in the development phase. Currently, there is only one type of NO{sub x} sensor that is sold commercially, and it seems unlikely to meet more stringent future emission requirements. Automotive exhaust sensor development has focused on solid-state electrochemical technology, which has proven to be robust for in-situ operation in harsh, high-temperature environments (e.g., the oxygen stoichiometric sensor). Solid-state sensors typically rely on yttria-stabilized zirconia (YSZ) as the oxygen-ion conducting electrolyte and then target ...

2010-11-01

93

Utilization of Fluorescent Microspheres and a Green Fluorescent Protein-Marked Strain for Assessment of Microbiological Contamination of Permafrost and Ground Ice Core Samples from the Canadian High Arctic  

UK PubMed Central (United Kingdom)

Fluorescent microspheres were applied in a novel fashion during subsurface drilling of permafrost and ground ice in the Canadian High Arctic to monitor the exogenous microbiological contamination of...Full Text Available

2005-02-01

94

Radionuclide X-ray fluorescence determination of Mn, Fe, Cu, Zn and Pb in wastewaters and sludges from wastewater treatment plants in Bratislava (SR)  

International Nuclear Information System (INIS)

Radiometric X-ray fluorescence analysis was used for the determination of Mn, Fe, Cu, Zn and Pb in wastewater and sludges from three wastewater treatment plants in Bratislava (SR). Metals were determined in wastewaters after preconcentration by 8-hydroxyquinoline and in sludges by drying and pressing to pellets. "2"3"8Pu and "1"0"9Cd was used for excitation of fluorescence radiation. (author).

1997-01-01

95

Radionuclide X-ray fluorescence analysis of components of the environment  

International Nuclear Information System (INIS)

The physical foundations and methodology are described of radionuclide X-ray fluorescence analysis. The sources are listed of air, water and soil pollution, and the transfer of impurities into biological materials is described. A detailed description is presented of the sampling of air, soil and biological materials and their preparation for analysis. Greatest attention is devoted to radionuclide X-ray fluorescence analysis of the components of the environment. (ES).

1983-01-01

96

Present state of radionuclide X-ray fluorescence analysis in coal mining  

International Nuclear Information System (INIS)

Applications of X-ray fluorescence analysis in coal mining and geology are briefly described based on results published in Czechoslovakia as well as abroad over the past 3 years. Particular attention is paid to the rapid determination of the ash content of coal using portable radionuclide X-ray fluorescence analyzers that are being developed in Czechoslovakia. (author).

1990-01-01

97

Pharmaceutics | Special Issue: Molecular Imaging  

Wastenet

...) Abstract: Fluorescence microscopic imaging is widely used in biomedical research to study molecular and cellular processes in cell culture or tissue samples. This is motivated by the high inherent sensitivity of fluorescence techniques, the spatial resolution that compares favorably with cellular dimensions, the stability of the fluorescent labels used and the sophisticated strategies that have been developed for selectively labeling target molecules. More recently, two and ...

98

Laser induced fluorescence measurements of the mixing of fuel oil with air  

Energy Technology Data Exchange (ETDEWEB)

We report on measurements of the mixing of fuel oil with air at atmospheric pressure in an industrial premixed gas turbine burner. The concentration of the vaporized fuel oil was measured with laser induced fluorescence. We reason that the fuel oil concentration can be considered with good accuracy as proportional to the fluorescence intensity. (author) 6 fig., 3 refs.

1999-08-01

99

Contribution to the in vitro multielement X-ray fluorescence analysis of human soft tissues  

International Nuclear Information System (INIS)

Determination of Mn, Fe, Ni, Cu, Zn, and Pb in human soft tissues by radionuclide X-ray fluorescence analysis (using "2"3"8Pu and "1"0"9Cd sources) is described. The results of multielement XRS analysis of selected human tissues are tabulated. They are in good agreement with the literature data. It is concluded that X-ray fluorescence technique is a suitable method for trace element determination. (author).

1986-11-01

100

Barrier filter for fluorescence microscopy of strongly autofluorescent plant tissues. Application to actin cables in Chara.  

Science.gov (United States)

A liquid barrier filter for use in fluorescence microscopy of strongly autofluorescent plant tissues is described. The filter consists of a methanol solution of cupric chloride and ferric chloride and isolates fluorescein fluorescence from the strong red autofluorescence of photosynthetic plant tissues. Subcortical actin cables in the giant alga Chara are being visualized through use of this filter together with heavy meromyosin labeling. PMID:90068

1979-05-01

101

Ultrafast fluorescence dynamics of Sybr Green I/DNA complexes  

British Library Electronic Table of Contents (United Kingdom)

The ultrafast dynamics of the DNA fluorescent dye Sybr Green I (SG) has been studied in buffer, single-stranded (ssDNA), double-stranded (dsDNA) and triple-stranded DNA (tsDNA). The fluorescence quantum yield of SG increases dramatically when bound to DNA (including tsDNA). The fluorescence dynamics of the free SG has shown two decay components with 0.15-0.4ps and 1.3-2.1ps time constants, depending on the fluorescence wavelength. Upon binding to DNA, the dynamics becomes slower exhibiting four decay components. This is mainly due to the restriction of the internal motions of the dye caused by the relatively rigid environment of the dye complexed with DNA.

2010-01-01

102

Spatial fluorescence cross correlation spectroscopy by means of a spatial light modulator  

CERN Document Server

Spatial Fluorescence Cross Correlation Spectroscopy is a rarely investigated version of Fluorescence Correlation Spectroscopy, in which the fluorescence signals from differ-ent observation volumes are cross-correlated. In the reported experiments, two observation volumes, typically shifted by a few $\\mu$m, are produced, with a Spatial Light Modulator and two adjustable pinholes. We illustrated the feasibility and potentiality of this technique by: i) measuring molecular flows, in the range 0.2 - 1.5 $\\mu$m/ms, of solutions seeded with fluorescent nanobeads or rhodamine molecules (simulating active transport phenomenons); ii) investigating the perme-ability of phospholipidic membrane of Giant Unilamellar Vesicles versus hydrophilic or hydrophobic molecules (in that case the laser spots were set on both sides of the mem-brane). Theoretical descriptions are proposed together with a discussion about FCS ...

2008-01-01

103

Highly-sensitive ion selective electrode based on molecularly imprinted polymer particles for determination of tetracycline in aqueous samples  

British Library Electronic Table of Contents (United Kingdom)

In this work, a highly-sensitive polymeric membrane ion selective electrode for determination of tetracycline was constructed by using molecularly imprinted polymer (MIP) particles as quasi-ionophore. The water-compatible MIP particles targeting tetracycline were synthesized with tetracycline as a template molecule, methacrylic acid as a functional monomer, ethylene glycol dimethacrylate as a cross-linker, 2,2?-azobisisobutyronitrile as an initiator and lanthanum ion as a mediator. Benefited from the distinctive performance of the quasi-ionophore and the optimized composition of the membrane and the inner filling solution, the lower detection limit of the electrode was decreased to about 1 ? 10?8 mol/l. It exhibited a good electrode slope 59.8 mV/decade near the theoretical Nernstian one, ...

2011-01-01

104

Development of the high sensitivity real-time neutron radiography for low-flux neutron sources  

Energy Technology Data Exchange (ETDEWEB)

The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose of developing a system with higher sensitivity, consideration of neutron statistics would be important. ...

1994-08-01

105

Development of the high sensitivity real-time neutron radiography for low-flux neutron sources  

International Nuclear Information System (INIS)

The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose of developing a system with higher sensitivity, consideration of neutron statistics would be important. ...

1994-01-01

106

Validation of biological markers for quantitative risk assessment.  

UK PubMed Central (United Kingdom)

The evaluation of biological markers is recognized as necessary to the future of toxicology, epidemiology, and quantitative risk assessment. For biological markers to become widely accepted, their validity...Full Text Available

1991-01-01

107

From Quantitative Microscopy to Automated Image Understanding  

UK PubMed Central (United Kingdom)

Quantitative microscopy has been extensively used in biomedical research and has provided significant insights into structure and dynamics at the cell and tissue level. The entire procedure...Full Text Available

2004-01-01

108

Right-sided invasive metastatic thymoma of the heart  

British Library Electronic Table of Contents (United Kingdom)

Cardiac tumours may display diverse symptoms through potential involvement of any structure of the heart. We describe a case of a highly malignant thymoma with involvement of different cardiac structures with important haemodynamic compromise. With the high sensitivity of transthoracic echocardiography for detection of intracardiac masses, computed tomography and magnetic resonance add essential structural preoperative information on the tumour and surrounding tissue as vessels, pleura, lung and mediastinum.

2011-01-01

109

Differences in sensitivity of Schistosoma mansoni schistosomula, Dirofilaria immitis microfilariae, and Nematospiroides dubius third-stage larvae to damage by the polyamine oxidase-polyamine system.  

UK PubMed Central (United Kingdom)

The effect of the polyamine oxidase (PAO)-polyamine system on some helminths was examined in vitro. Both Schistosoma mansoni schistosomula and Dirofilaria immitis microfilariae were highly sensitive...Full Text Available

1986-09-01

110

Development of techniques for joining of high-sensitivity solar cells. Final report; Entwicklung von Verbindungstechniken fuer hoch empfindliche Solarzellen. Abschlussbericht  

Energy Technology Data Exchange (ETDEWEB)

The report investigates a number of joining techniques, i.e. isothermal solidification, ultrasonic welding, thermocompression, and glueing. (HW) [Deutsch] In diesem Vorhaben wurden verschiedene Verbindungstechniken untersucht: Isotherme Erstarrung; Ultraschall-Schweissen; Thermokompression; Leitkleben. (HW)

1992-09-01

111

An ADP proposal to study the formation and evolution of dust-embedded clusters. Final report  

International Nuclear Information System (INIS)

Using high resolution and high sensitivity IRAS data at 12 and 25 microns low mass stars were studied which have recently formed in the Ophiuchus, Corona Australis, and IC1396 dark clouds. The successful application of these techniques to the Rho Ophiuchi infrared cluster is briefly described. The status of research performed is also presented.

112

Ambient water-quality criteria for ammonia (salt water)-1989  

Energy Technology Data Exchange (ETDEWEB)

Ammonia is a common and highly toxic pollutant which, in sufficient quantities, will adversely affect aquatic organisms. This ammonia criteria document for salt water will allow establishment of regulatory standards for ammonia discharge into estuaries, near coastal zones and oceans. Possible adverse impacts in highly sensitive and abundant ecosystems such as estuaries make regulation particularly important.

1989-04-01

113

A high-sensitivity small animal SPECT system  

International Nuclear Information System (INIS)

Medical imaging using single gamma-ray-emitting radionuclides typically makes use of parallel hole collimators or pinholes in order to achieve good spatial resolution. However, a tradeoff in sensitivity is inherent in the use of a collimator, and modern preclinical single photon emission computed tomography (SPECT) systems detect a very small fraction of emitted gamma rays, often less than 0.1%. A system for small animal SPECT imaging which uses no collimators could potentially achieve very high sensitivity-several tens of percent-with reasonably sized detectors. This would allow two significant improvements in preclinical studies: images could be obtained more rapidly, allowing higher throughput for screening applications, or for dynamic processes to be observed with very good time resolution; and images could be obtained with less radioactive tracer, making possible the in vivo imaging of low-capacity receptor systems, aiding research into ...

2009-03-07

114

Detection of constitutive heterodimerization of the integrin Mac-1 subunits by fluorescence resonance energy transfer in living cells  

International Nuclear Information System (INIS)

Macrophage differentiation antigen associated with complement three receptor function (Mac-1) belongs to #beta#_2 subfamily of integrins that mediate important cell-cell and cell-extracellular matrix interactions. Biochemical studies have indicated that Mac-1 is a constitutive heterodimer in vitro. Here, we detected the heterodimerization of Mac-1 subunits in living cells by means of two fluorescence resonance energy transfer (FRET) techniques (fluorescence microscopy and fluorescence spectroscopy) and our results demonstrated that there is constitutive heterodimerization of the Mac-1 subunits and this constitutive heterodimerization of the Mac-1 subunits is cell-type independent. Through FRET imaging, we found that heterodimers of Mac-1 mainly localized in plasma membrane, perinuclear, and Golgi area in living cells. Furthermore, through analysis of the estimated physical distances between cyan ...

2006-08-04

121
122

State analysis of sulfur in coal and coal fly ash by double-crystal X-ray fluorescence spectrometry  

Energy Technology Data Exchange (ETDEWEB)

Double-crystal high-resolution x-ray fluorescence spectrometry was applied to the state analysis of sulfur in coal and related fly ash. For total sulfur, a proportional relationship exists between fluorescence intensities and the analytical values obtained by the oxygen-combustion method. Two oxidation states of sulfur were identified by a least square curve fitting method, by assuming that the spectrum profile is identical for each sulfur state but the intensity and position are different. The chemical state of sulfur in coal and remaining in fly ash is discussed.

1983-01-01

123

X-Ray Fluorescence Analysis of Composite Propellants for ...  

Science.gov (United States)

... The constancy of the X-ray intensity ratio for each element in Table 8 as the X-ray tube settings were changed shows the excellent compensating ...

1977-06-03

125

Stress Tolerance of Photosystem II in Vivo  

UK PubMed Central (United Kingdom)

The in vivo photochemical activity of photosystem II was inferred from modulated chlorophyll fluorescence and photoacoustic measurements in intact leaves of several plant species (Lycopersicon...Full Text Available

1992-09-01

126

SHORT PULSE LASERS  

Science.gov (United States)

... main in this state only for 10-8 secs., after which they decay to the meta- stable state (fluorescent level) because of spontaneous radiation or other ...

1962-10-01

129

Photophysical properties of new psoralen derivatives: psoralens linked to adenine through polymethylene chains  

International Nuclear Information System (INIS)

The model compounds, 8-methoxypsoralen-CH_2O(CH_2)_n-adenine (MOPCH_2OC_nAd, n=2,3,5,6,8, and 10) in which 5 position of 8-methoxypsoralen (8-MOP) is linked by various lengths of polymethylene bridge to N"9 of adenine. UV absorption spectra are identical with the sum of MOPCH_2OC3 and adenine absorption spectra. Solvent effect on the UV absorption and fluorescence emission spectra indicate that the lowest excited singlet state is the (#pi##->##pi#"*) state. The spectral characteristics of the fluorescence of MOPCH_2OC_nAd are strongly dependent upon the nature of the solvents. The fluorescence emission spectra in aprotic solvents are broad and structrueless due to the excimer formation through the folded conformation accelerated by hydrophobic #pi#-#pi# stacking interaction. Increasing polarity of the protic solvents leads to higher population of unfolded conformation stabilized through favorable solvation and H-bonding, ...

2002-10-01

130

Phase-Sensitive Fluorescence Study of Mono-L-Aspartyl ...  

Science.gov (United States)

... of perylene were measured with the Shimadzu UV-2500 UV-VIS spectrophotometer (Kyoto, Japan) to determine their molar extinction coefficients. ...

2001-10-25

131

PRICES SUBJECT To CHq.G - NASA Technical Report Server (NTRS)  

Science.gov (United States)

by the radionuclide X-ray fluorescence analysis into several groups according to the atomic number of the determined element. Table I documents this. ...

132

N94- 31026 - NASA Technical Report Server (NTRS)  

Science.gov (United States)

in early 1992 from Lord Corporation, were also found. For both the reflective and absorptive polyurethanes, the fresh paint fluoresces significantly ...

134

Color Fluorescence Ratio for Detection of Bronchial Dysplasia and Carcinoma In situ  

UK PubMed Central (United Kingdom)

BackgroundAutofluorescence bronchoscopy is more sensitive than conventional bronchoscopy for detecting early airway mucosal lesions. Decreased specificity can lead...Full Text Available

2009-07-15

136

Application of laser fluorimetry for determining the influence of a single amino-acid substitution on the individual photophysical parameters of a fluorescent form of a fluorescent protein mRFP1  

International Nuclear Information System (INIS)

Individual photophysical parameters of the chromophore of a fluorescent protein mRFP1 and its two mutants (amino-acid substitution at position 66 - mRFP1/ Q66C and mRFP1/Q66S proteins) are determined. For this purpose, apart from conventional methods of fluorimetry and spectrophotometry, nonlinear laser fluorimetry is used. It is shown that the individual extinction coefficients of the chromophore of proteins correlate (correlation coefficient above 0.9) with the volume of the substituted amino-acid residue at position 66 (similar to the positions of the absorption, fluorescence excitation and emission maxima). (laser biology and medicine)

2009-03-31

137
138

 

UK PubMed Central (United Kingdom)

Enteropathogenic E. coli were sought routinely by the fluorescent antibody technique, using monovalent and polyvalent conjugates (rhodamine sulfonyl· chloride, fluorescein and rhodamine isothiocyanate)....Full Text Available

1962-11-03

139

Time-resolved confocal fluorescence spectroscopy reveals the structure and metabolic state of epithelial tissue  

Science.gov (United States)

Autofluorescence spectroscopy has been a widely explored technique for in vivo and noninvasive diagnosis of pre-cancer lesions in epithelium where 90% cancers originate. For extracting more accurate fluorescence information for cancer diagnosis, depth-resolved fluorescence measurements are crucial to assess NADH and FAD in non-keratinized epithelial layer and collagen in stromal layer, respectively. In this study, we achieved the depth-resolved fluorescence spectral measurements of squamous epithelial tissue based on confocal technique. We found that in non-keratinized epithelial layer the fluorescence signals excited at 405 nm were the combination of NADH and FAD fluorescence and could be used for evaluating the redox ratio. Moreover, we found that confocal time-resolved autofluorescence measurements of epithelial tissue with 405 nm excitations could provide the information on the ...

2007-03-01

140

Theoretical transition energies, lifetimes and fluorescence yields of multiply ionized silicon  

Energy Technology Data Exchange (ETDEWEB)

Theoretical x-ray transition energies, lifetimes and partial multiplet fluorescence yields are presented for all spectroscopic terms of electron configurations with a single K-shell vacancy and varying number of electrons in the L-shell and M/sub 1/-subshell for multiply-ionized silicon. 9 tables.

1982-01-01

141

The fatty acid analogue 11-(dansylamino)undecanoic acid is a fluorescent probe for the bilirubin-binding sites of albumin and not for the high-affinity fatty acid-binding sites.  

UK PubMed Central (United Kingdom)

1. The fluorescent fatty acid probe 11-(dansylamino)undecanoic acid (DAUDA) binds with high affinity to bovine and human serum albumin (BSA and HSA) at three sites. 2. The Kd of the primary binding...Full Text Available

1990-08-15

142

Structural basis of binding of fluorescent, site-specific dansylated amino acids to human serum albumin  

UK PubMed Central (United Kingdom)

Human serum albumin (HSA) has two primary binding sites for drug molecules. These sites selectively bind different dansylated amino acid compounds, which—due to their intrinsic fluorescence—have...Full Text Available

2011-04-01

143

Rubidium 5"2P fine-structure transitions induced by collisions with potassium and caesium atoms  

International Nuclear Information System (INIS)

A diode-laser fluorescence experiment was performed in order to study fine-structure transitions between 5"2P states of rubidium atoms colliding with ground-state potassium or caesium atoms. The Rb(5"2P_3_/_2) state was optically excited and the intensity ratio of sensitized to direct fluorescence was measured. (author).

144

Radionuclide X-ray fluorescence determination of Cr, Fe, Cu, Zn,and Pb in industrial wastewaters after preconcentration of determined elements  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis was used for the determination of Cr, Fe, Cu, Zn and Ph in industrial wastewaters (from surface treatment of metals and glasses) after precipitation of determined elements by 8-hydroxyquinoline. (author).

1997-01-01

145

Radionuclide X-ray fluorescence analysis of solid aerosol particles on Synpor 4 collection filters  

International Nuclear Information System (INIS)

The feasibility was studied of the application of radionuclide X-ray fluorescence analysis to the identification and determination of chemical elements in the air. A description of the method is presented, the main stages of the analysis are discussed (sample preparation and standards, selection of radioactive radiation sources, geometry of measurement and evaluation of results). The method is illustrated on the determination of elements Fe, Cu, Zn, Br, and Pb in air samples taken in the city of Prague. (author) 2 tabs., 2 figs., 14 refs.

1992-01-01

146

Nondestructive determination of airborne lead particulates by the radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).

1980-01-01

147

Heavy metals in industrial wastewater determined by radionuclide x-ray fluorescence analysis and their effects on Allium cepa root tip cells  

International Nuclear Information System (INIS)

Radionuclide x-ray fluorescence method was used in the determination of Cr, Ni and other heavy metals content in wastewater of an engineering plant taken both before and after chemical treatment. Toxic effects of the wastewaters using Allium cepa root tip cells were tested. (author) 8 refs.; 2 tabs.

1994-05-01

148

Heavy metals and some other elements in medicinal plants. Determined by X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Determination of Mn, Fe, Cu, Zn, Hg, Pb, Br, Se, Rb, Sr and Cd in the medicinal plants by radionuclide X-ray fluorescence analysis (using "2"3"8Pu, "2"4"1Am/Ag and "1"2"5I) is described. (author). 12 refs., 2 tabs.

1995-01-01

149

Heavy element contamination of surface waters in the region Banska Stiavnica (SR) measured by radionuclide X/ray fluorescence analysis  

International Nuclear Information System (INIS)

Heavy metals (Pb, Cd, Mn, Cu, Zn, Fe) were determined in surface waters in the surroundings of the depositories of the mining shrubs in the region of Banska Stiavnica (SR) by radionuclide X-ray fluorescence analysis. Allowed concentrations of the determined metals are exceeded numerously (multiplicity in some cases was 10"3-10"6). (author).

1997-01-01

150

Evaluation of adhesive plasters by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

A radiometric method was elaborated for surface density determinations of the adhesive layer of plasters by radionuclide X-ray fluorescence using the 17.47 keV bremsstrahlung of "1"4"7Pm/Mo. The bremsstrahlung line excites the 8.63 keV characteristic K#alpha# line of Zn contained in the adhesive layer of the plaster as a filling material in the form of ZnO. In homogeneous adhesive layers the Zn content is proportional to surface density. (author).

1976-01-01

151

Determination of cesium and selenium in cultivated mushrooms using radionuclide X-ray fluorescence technique  

International Nuclear Information System (INIS)

Cesium and selenium intake of cultivated mushrooms (Agaricus bisporus), with these elements previously added to culture medium, has been examined from the viewpoint of health- and environmental protection. The process of measuring has been carried out by the radionuclide X-ray fluorescence technique. Treatments of the elementary substance with Se salt appears to influence the Se content of the mushrooms to a significant extent. Cs intake is of considerable importance, as this element is accumulated by mushrooms. (author)

2000-09-01

152

Determination of ash in coal by X-ray backscattering and X-ray fluorescence analysis and apparatus by the PAR company  

International Nuclear Information System (INIS)

The basic principles of determination of the ash content of coal by the title methods are outlined. A brief technical characteristic of the ash meters and radionuclide X-ray fluorescence analyzers manufactured by the PAR company is presented. (Z.S.). 4 figs., 7 refs.

1993-01-01

153

Determination of Y, Ba and Cu in superconductor films by x-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide x-ray fluorescence analysis was used for the determination of Y, Ba and Cu in thin high-temperature superconducting films. Atomic emission ICP spectrometry was used to estimate the precision and accuracy of analytical results. Reasonable agreement between both methods was obtained when a polynomial calibration curve was applied. (author) 4 refs.; 4 tabs.

1994-06-01

154

Determination of Fe and Zn in healing plants by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence method was used for the determination of Fe and Zn in healing plants (Sage, Peppermint, Stinging, Common Agrimony, Milfoil, Ribwort, Tansy, White Dead-Nettle). "2"3"8Pu exciting source and Si/Li semiconductor detector were used for the determination. (author)

1999-06-01

155

Determination of Fe and Zn in agricultural plants with special cultivation by radionuclide x-ray fluorescence analysis  

International Nuclear Information System (INIS)

Fe and Zn were determined in various parts of maize (Zea mays) in dependence on quantity of organic substrate EKOFERT as organic fertilizer in soil, using radionuclide X-ray fluorescence analysis. The increase of quantity of organic substrate EKOFERT in soil causes a decrease of heavy metal concentrations in certain parts of the plant. (author). 4 refs., 1 tab.

1996-01-01

156

Determination of Cu, Ni, Zn and Pb contents in taraxacum officinale near the highway D-61 Bratislava-Trnava (SR) by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence method with Si/Li semiconductor detector and "2"3"8Pu exciting source was used for the determination of Cu, Ni, Zn and Pb in plant samples (Taraxacum officinale) from various localities near the highway D-61 Bratislava-Trnava (SR). (author) 2 refs.; 1 fig.; 1 tab.

1993-12-01

157

Determination of Cu, Ni, Zn and Pb contents in soil near the D-61 Bratislava-Trnava Highway by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence method with Si/Li semiconductor detector and "2"3"8Pu exciting source was used for the determination of Cu, Ni, Pb, and Zn in soil samples from various localities near the D-61 Bratislava-Trnava highway (CSFR). (author) 1 ref.; 1 tab.

1993-01-01

158

Analysis of high-temperature superconducting films by x-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis was used for the determination of Cu, Y and Ba in very thin high-temperature superconducting films. The precision of the method is better than 3% for about 1 #mu#m thick films. The atomic emission ICP spectrometry was used to testify results of XRF analysis. An acceptable agreement of both methods was obtained. (author) 4 refs.; 2 tabs.

1991-09-01

159

7. Overview of radionuclide X-ray fluorescence analysis of components of the environment  

International Nuclear Information System (INIS)

A survey is presented of studies dealing with radionuclide X-ray fluorescence analysis (RXFA) of impurities in the air, water, soil, sediments and biological materials, mainly blood, urine, hair, soft tissues and bones. Tabulated are lists of published works on RXFA of the air, water and biological materials. (ES).

1983-12-01

160

Which differential circuit breaker in tomorrows accommodation?; Quel disjoncteur differentiel dans l'habitat de demain?  

Energy Technology Data Exchange (ETDEWEB)

Since several years, several manufacturers of circuit breakers from various countries (South Africa, UK, The Netherlands, USA..) try to impose in accommodations a highly sensitive electronic-type of differential circuit-breaker initially devoted to industrial installations where qualified and experienced professionals are present. This technical paper presents first the principles of the classical electromechanical circuit breakers and of the electronic circuit breaker, and then compares their relative efficiency and level of safety in residential use conditions (grounding schemes, voltage drops, rupture of the neutral conductor, rupture of the phase conductor, overvoltages). (J.S.)

2000-04-01

161

Using focused ion beam damage patterns to photoelectrochemically etch features in III-V materials  

Energy Technology Data Exchange (ETDEWEB)

A method of patterning n-type GaAs, InP, InGaAs, and InGaAsP by photoelectrochemical (PEC) etching in conjunction with a submicron focused ion beam (FIB) at low dose is described. The ion beam is used to produce damage in a desired pattern in the material. Subsequent PEC etching of the material reveals the ion induced features in relief. The procedure is highly sensitive, requiring a dose of only 5 x 10/sup 9/ ions/cm/sup 2/ for the differential etch to become apparent. The sensitivity allows rapid pattern generation in our FIB system.

1986-03-10

162

Towards Antihydrogen Trapping and Spectroscopy at ALPHA  

CERN Document Server

Spectroscopy of antihydrogen has the potential to yield high-precision tests of the CPT theorem and shed light on the matter-antimatter imbalance in the Universe. The ALPHA antihydrogen trap at CERN's Antiproton Decelerator aims to prepare a sample of antihydrogen atoms confined in an octupole-based Ioffe trap and to measure the frequency of several atomic transitions. We describe our techniques to directly measure the antiproton temperature and a new technique to cool them to below 10 K. We also show how our unique position-sensitive annihilation detector provides us with a highly sensitive method of identifying antiproton annihilations and effectively rejecting the cosmic-ray background.

2011-01-01

163

Sudbury neutrino detector  

International Nuclear Information System (INIS)

The proposed Sudbury Neutrino Observatory is based on a Cherenkov detector which has a total of 1000 tonne of heavy water and 1800 tonne of light water for its sensitive volume. The detector is optimized for the measurement of extra-terrestrial low energy electron neutrinos and electron antineutrinos spectra as well as the total neutrino flux independent of neutrino flavours. It will delineate the Standard Solar Model and neutrino propagation aspects of the solar neutrino problem, provide detailed information on the dynamics of stellar collapse and measure neutrino masses and oscillation parameters with high sensitivity.

164

Shot-noise-limited measurement of sub-parts-per-trillion birefringence phase shift in a high-finesse cavity  

International Nuclear Information System (INIS)

We report on a promising approach to high-sensitivity anisotropy measurements using a high-finesse cavity locked by optical feedback to a diode laser. We provide a simple and effective way to decouple the weak anisotropy of interest from the inherent mirror's birefringence whose drift may be identified as the key limiting parameter in cavity-based techniques. We demonstrate a shot-noise-limited phase shift resolution previously inaccessible in an optical cavity, readily achieving the state-of-the-art level of 3x10"-"1"3 rad.

2010-09-01

165

Low cost, low power, high sensitivity, real time neutron detection microsystem  

International Nuclear Information System (INIS)

A Si array neutron detector is proposed based on commercial CCD and CMOS sensor technology coupled with a thin film neutron conversion coating. System sensitivity is estimated for a baseline device containing a single array and various schemes to increase detection probability by simple area scaling and stacking are discussed. Some possible use scenarios are discussed involving static and moving sources. Likely neutron source fluxes for weapons grade and commercial grade nuclear material are estimated along with expected intensities of cosmic background neutrons which would establish a noise floor to detection limits.

2002-10-10

166

Electron impact ionization of C_6_0 and C_7_0 and decay of the singly and multiply charged (up to z=7) ions produced  

International Nuclear Information System (INIS)

Mass spectrometry was instrumental in the discovery of the fullerenes and the characterization of their special structure (truncated icosahedron). High resolution and high sensitivity mass spectrometry in combination with a crossed molecular beam/electron beam ion source is used here to study a further, very unique property of singly and multiply charged fullerene ions (up to Z=7), i.e. their strong resilience towards decomposition via sequential C_2 evaporation and via Coulomb explosion, respectively. (author).

1994-03-20

167

A high-sensitivity scintillation chamber for radon in gas  

Energy Technology Data Exchange (ETDEWEB)

A large scintillation chamber of 6.7 l volume for direct radon concentration measurements in gas is presented. With two 5 in. photomultipliers on opposite sides, working in coincidence, a concentration as low as about 0.5 mBq/l is detectable with 10% standard deviation after 1000 min measuring time. With the achieved background count rate of 0.42 counts/min and the counting efficiency of 0.607 for [sup 222]Rn and its progenies the absolute minimal detectable specific activity is reached with 0.17 mBq/l at about 12 000 min. The method to determine this minimum detectable activity is outlined. ((orig.))

1994-06-15

168

Role of Quantitative Bone Scanning in the Assessment of Bone Turnover in Patients With Charcot Foot  

UK PubMed Central (United Kingdom)

OBJECTIVETo assess the new quantitative bone scan parameters as markers of Charcot neuroosteoarthropathy (CNO) activity.RESEARCH DESIGN AND METHODSForty-two...Full Text Available

2010-02-01

169

Quantitative structure-activity relationships of insecticides and plant growth regulators: comparative studies toward understanding the molecular mechanism of action.  

UK PubMed Central (United Kingdom)

Emphasis was put on the comparative quantitative structure-activity approaches to the exploration of action mechanisms of structurally different classes of compounds showing the same type of activity...Full Text Available

1985-09-01

170

Quantitative evaluation of siRNA delivery in vivo  

UK PubMed Central (United Kingdom)

Effective small interfering RNA (siRNA)–mediated therapeutics require the siRNA to be delivered into the cellular RNA-induced silencing complex (RISC). Quantitative information of this essential...Full Text Available

2010-12-01

171

Quantitation of Antibody to Non-Hemagglutinating Viruses by Single Radial Hemolysis: Serological Test for Human Coronaviruses  

UK PubMed Central (United Kingdom)

A single radial hemolysis test was developed for quantitation of specific antibody to non-hemagglutinating viruses. With the human coronaviruses as models, this test utilizes the binding properties...Full Text Available

1977-06-01

172

Mapping Quantitative Trait Loci Controlling Milk Production in Dairy Cattle by Exploiting Progeny Testing  

UK PubMed Central (United Kingdom)

We have exploited ``progeny testing'' to map quantitative trait loci (QTL) underlying the genetic variation of milk production in a selected dairy cattle population. A total of 1,518 sires, with progeny...Full Text Available

1995-02-01

173

From Classical Genetics to Quantitative Genetics to Systems Biology: Modeling Epistasis  

UK PubMed Central (United Kingdom)

Gene expression data has been used in lieu of phenotype in both classical and quantitative genetic settings. These two disciplines have separate approaches to measuring and interpreting epistasis, which...Full Text Available

2008-03-01

174

Fabp7 Maps to a Quantitative Trait Locus for a Schizophrenia Endophenotype  

UK PubMed Central (United Kingdom)

Deficits in prepulse inhibition (PPI) are a biological marker for schizophrenia. To unravel the mechanisms that control PPI, we performed quantitative trait loci (QTL) analysis on 1,010 F2 mice derived...Full Text Available

2007-11-01

175

Evaluation of the ERETIC Method as an Improved Quantitative Reference for 1H HR-MAS Spectroscopy of Prostate Tissue  

UK PubMed Central (United Kingdom)

The Electronic REference To access In vivo Concentrations (ERETIC) method was applied to 1H HR-MAS spectroscopy. The accuracy, precision, and stability of ERETIC as a quantitative...Full Text Available

2009-03-01

176

SIMV: An Application of Mathematical Modeling in Ventilator Management  

UK PubMed Central (United Kingdom)

SIMV (simulation and modeling of ventilation) is a quantitative system for the mathematical modeling and simulation of pulmonary...Full Text Available

1989-11-08

178

Interest of quantitative bone scintigraphy  

International Nuclear Information System (INIS)

French 1979. p. 4.35-4.48. France Granier, R. Bittoun, J. Doury, P. Pattin,

182

Quantitative phase imaging using hard x-rays  

International Nuclear Information System (INIS)

The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.

2009-02-01

183

State analysis of sulfur in coal and coal fly ash by double-crystal X-ray fluorescence spectrometry  

Energy Technology Data Exchange (ETDEWEB)

Double-crystal high-resolution X-ray fluorescence spectrometry was applied to the state analysis of sulfur in coal and related fly ash. For total sulfur, a proportional relationship exists between fluorescence intensities and the analytical values obtained by the oxygen-combustion method. Two oxidation states of sulfur were identified by a least square curve fitting method, by assuming that the spectrum profile is identical for each sulfur state but the intensity and the position are different. Sulfur in coal mainly consists of S/sup 2 -/, whereas that in coal fly ash mainly consists of S/sup 6 +/. As much as 0.04-0.08% of S/sup 2 -/ remains in fly ash.

1983-01-01

184

Research on improving utilization efficiency of photoelectric cell by using fluorescence material  

Energy Technology Data Exchange (ETDEWEB)

This paper proves that it is practicable to build a new power model which can work efficiently at night by using a type of fluorescence material. The utilization efficiency of photovoltaic cell is improved by prolonging the actual working hours of the cell within 24 hours. Both theoretical analysis and experiment on this model are carried out, and base on which the current-time curve (I-t curve) is depicted. It shows that the model which applies the fluorescence material to photovoltaic system is available. According to the analysis and comparison between the attenuating curve of the material and I-t curve of the power system, we can conclude that the weak illumination and the mismatch on wavelength are primary reasons for the low current. Finally, several improved measures of this power model for practical application are given, and it is expected to provide a new thought for photovoltaic study. (orig.)

2008-07-01

185

PKH26 as a fluorescent label for live human umbilical mesenchymal stem cells  

British Library Electronic Table of Contents (United Kingdom)

To determine whether PKH26 labeling affects the morphologies, phenotypes, proliferation, and secretion abilities of human umbilical mesenchymal stromal cells (HUMSCs) were investigated. Isolated HUMSCs were labeled with PKH26, and cell morphology was observed under microscope. Cell cycle, apoptotic cell death, expression of PKH26, and the proliferation rate were evaluated. Additionally, fluorescence intensity of PKH26 labeling at different passage times was quantified. There were no detectable differences in cell morphology, cell growth, and proliferation rate after PKH26 labeling. In addition, fluorescence intensity of PKH26 labeling was gradually reduced with increase of the passage times. The PKH26 labeling disappeared after passage six times. In summary, PKH26 labeling is a safe and ef...

2011-01-01

186

Multielement analysis of air samples. Determination of iron, zinc, lead, and bromine content by the radionuclide X-ray fluorescence analysis  

Energy Technology Data Exchange (ETDEWEB)

Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A /sup 238/Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed.

1981-01-01

187

Mitochondrial sequestration of BCECF after ester loading in the giant alga Chara australis  

British Library Electronic Table of Contents (United Kingdom)

Summary. Ratiometric fluorescent dyes are often used to monitor free ion concentrations in vivo, especially in cells that are recalcitrant to transformation with genetically encoded fluorescent markers. Although intracellular dye distributions are often found to be cytosolic, dye localisation has often not been examined in detail. We began exploring the use of BCECF (2?,7?-bis(2-carboxyethyl)-5(6)-carboxyfluorescein) to monitor pH in the giant alga Chara australis and discovered that younger leaf cells could be loaded using the acetoxymethyl ester of BCECF. However, we were puzzled to find in microphotometric measurements that the fluorescence ratio appeared insensitive to manipulations affecting cytosolic pH. Confocal imaging of C. australis cells loaded with BCECF showed an accumulation ...

2007-01-01

188

Micro-patterning of chemical functionality of anthracene-bis-resorcinol film using focused ion beam  

International Nuclear Information System (INIS)

Anthracene-bis-resorcinol is an interesting molecule as it forms a hydrogen-bonded network when guest molecules with weak polarity are included. Focused ion beam (FIB) was irradiated on a part of its amorphous film with low dose, and the film was exposed to the vapor of guest molecules. From fluorescence and AFM analyses of this film, it was found that no inclusion compound was formed in FIB irradiated area, i.e. FIB irradiation suppresses the ability to form the inclusion compounds. By utilizing this phenomenon, we succeeded in a microfabrication of relief structures consisting of inclusion compounds which has different fluorescence from its surrounding. Morphology, fluorescence, and IR absorption analyses indicated that hydroxyl or resorcin groups are damaged by ion beams, and consequently a formation of hydrogen-bonded networks, which play a role of a lattice caging guest molecules, becomes impossible.

2005-12-15

189

Influence of alloying effect on X-ray fluorescence parameters of Co and Cu in CoCuAg alloy films  

British Library Electronic Table of Contents (United Kingdom)

In this study, Kb/Ka X-ray intensity ratios, Formula Not Shown , Formula Not Shown production cross-sections and K fluorescence yields of Co and Cu and Lb/La X-ray intensity ratios, Formula Not Shown , Formula Not Shown production cross-sections and Formula Not Shown average fluorescence yields of Ag in pure metals and in different alloy compositions were measured. In this study, alloying effects on the Formula Not Shown production cross-sections of Co and Cu were investigated and changes interpreted according to the rearrangement of valance state electrons and the charge transfer process between the 3d elements (Co and Cu) and Ag.

2009-01-01

190

Exciplex processes involving trans naphthylethylenes. Implications of ground-state conformeric equilibria  

Energy Technology Data Exchange (ETDEWEB)

Five arylethylenes with 1-naphthyl, 2-naphthyl, and phenyl groups in 1,2-positions have been studied for singlet-mediated charge-transfer interactions with several amines and paraquat dication. 1-Phenyl-2-(2-naphthyl)ethylene and 1,2-di(2-naphthyl)ethylene exhibit distinct dependence of exciplex emission maxima and lifetimes, and fluorescence quenching constants, on excitation and/or monitoring wavelengths; this is in conformity with the existence of ground-state rotamers for these systems, wtih distinguishable absorption-emission spectra and fluorescence lifetimes. The fluorescence quenching by aromatic amines and paraquat dication occurs with rate constants in the limit of diffusion control and is accompanied by the formation of radical ions in polar solvents (acetonitrile). The transient spectra and kinetics associated with the radical ions, observed by 337.1- and 355-nm laser flash photolysis, are also reported. 10 ...

1983-05-12

191

Detection of Fluorescence for Lanthanides in LiCl-KCl Molten Salt Medium  

Energy Technology Data Exchange (ETDEWEB)

In the electrorefining step of the pyrochemical process, actinide ions dissolved in the LiCl-KCl eutectic salt are recovered as pure actinide metals at a cathode for a re-use as a nuclear fuel from the aspect of its nonproliferation of the nuclear fuel cycles. The lanthanide species dissolved in the LiCl-KCl eutectic salt play an important role in an effective metal purification during the electrorefining step, so it is necessary to understand the chemical and physical behaviors of lanthanides in molten salt. The in situ spectroscopic measurement system and studies according to temperature changes are essential for better understandable information. To our knowledge, the absorption studies of lanthanides at high temperatures have been reported before, but the fluorescence studies of those at high temperature are not reported yet. We will discuss here the fluorescence behaviors of lanthanides in LiCl-KCl molten salt medium according to a ...

2007-10-15

192

Detection of Fluorescence for Lanthanides in LiCl-KCl Molten Salt Medium  

International Nuclear Information System (INIS)

In the electrorefining step of the pyrochemical process, actinide ions dissolved in the LiCl-KCl eutectic salt are recovered as pure actinide metals at a cathode for a re-use as a nuclear fuel from the aspect of its nonproliferation of the nuclear fuel cycles. The lanthanide species dissolved in the LiCl-KCl eutectic salt play an important role in an effective metal purification during the electrorefining step, so it is necessary to understand the chemical and physical behaviors of lanthanides in molten salt. The in situ spectroscopic measurement system and studies according to temperature changes are essential for better understandable information. To our knowledge, the absorption studies of lanthanides at high temperatures have been reported before, but the fluorescence studies of those at high temperature are not reported yet. We will discuss here the fluorescence behaviors of lanthanides in LiCl-KCl molten salt medium according to a ...

2007-10-01

193

Width of the 1.836-MeV level in "8"8Sr  

International Nuclear Information System (INIS)

Using bremsstrahlung, the resonance fluorescence yield has been measured for the 1.836-MeV 2"+_1 level in "8"8Sr. The observed yield corresponds to a level width GAMMA = 2.94 +- 0.15 meV.

194

Understanding Enzyme Activity Using Single Molecule Tracking (Poster)  

Energy Technology Data Exchange (ETDEWEB)

This poster describes single-molecule tracking and total internal reflection fluorescence microscopy. It discusses whether the carbohydrate-binding module (CBM) moves on cellulose, how the CBM binds to cellulose, and the mechanism of cellulosome assembly.

2009-06-01

195

The Arabidopsis ref2 Mutant Is Defective in the Gene Encoding CYP83A1 and Shows Both Phenylpropanoid and Glucosinolate Phenotypes  

UK PubMed Central (United Kingdom)

The Arabidopsis ref2 mutant was identified in a screen for plants having altered fluorescence under UV light. Characterization of the ref2 mutants showed that they...Full Text Available

2003-01-01

196

Site-specific modification of albumin by free radicals. Reaction with copper(II) and ascorbate.  

UK PubMed Central (United Kingdom)

Exposure of albumin to Cu(II) (10-100 microM) and ascorbate (0.1-2 mM) results in extensive molecular modifications, indicated by decreased fluorescence and chain breaks. The rate of utilization of...Full Text Available

1986-06-01

197

STS-83 - Johnson Space Center - NASA  

Science.gov (United States)

Radiation Measurement in Crew Compartment. DTO 805: .... spacecraft and aircraft propulsion, and hazardous waste disposal. ...... combustion reactions in a turbulent chemical kinetic flow reactor using laser induced fluorescence and ...

198

Role of Methoxypolyethylene Glycol on the Hydration, Activity, Conformation and Dynamic Properties of a Lipase in a Dry Film  

UK PubMed Central (United Kingdom)

A combined approach based on the use of ATR-FT/IR and steady-state fluorescence spectroscopy allowed to shed light on the effects of the additive methoxypolyethylene glycol (MePEG) on the hydration,...Full Text Available

2008-10-01

199

Ring opening reaction dynamics of a photochromic diarylethene derivative dye  

International Nuclear Information System (INIS)

Ring opening dynamics of diarylethene derivative (BTF6) in n-hexane are studied by femtosecond transient absorption and time resolved spontaneous fluorescence techniques. Cyclo-reversion time constant is obtained.

2001-11-01

200

Phagocytic response of bovine polymorphonuclear leukocytes to different incubation conditions and following exposure to some effectors of phagocytosis and different anticoagulants in vitro.  

UK PubMed Central (United Kingdom)

The ability of bovine polymorphonuclear leukocytes (PMN) to phagocytose fluorescent beads in vitro was studied using flow cytometry. The effects of varying laboratory conditions (bead:PMN ratio, length...Full Text Available

2001-01-01

201

Nitric Oxide-Mediated Tumoricidal Activity of Murine Microglial Cells12  

UK PubMed Central (United Kingdom)

Experimental metastases in the brain of mice are infiltrated by microglia, and parabiosis experiments of green fluorescent protein (GFP+) and GFP- mice revealed that these microglia...Full Text Available

202

Measurements and elimination of Cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry  

International Nuclear Information System (INIS)

In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component of a fiber-optic ...

2007-08-21

203

Measurement of reactor tube cladding thickness by x-ray fluorescence spectrometry  

International Nuclear Information System (INIS)

An x-ray fluorescence spectrometer was designed and fabricated which nondestructively determines the thickness of aluminum cladding at small suspected thin spots in the inner or outer surface of actinide reactor tubes. The analysis method is based on the difference in absorption of actinide L/sub #alpha#/ and L/sub #beta#/ fluorescent x-rays in passing through the cladding. Calibration plots of the logarithm of the L/sub #beta#//L/sub #alpha#/ x-ray intensity ratio versus cladding thickness are linear to at least 40 mils for U-Al, U_3O_8-Al, and PuO_2-Al substrates. Accuracy and precision of the experimentally determined cladding thickness and evaluated for both uranium and plutonium substrates. Experimental thickness data are reported for 618 quality assurance analyses on six Mark 41 PuO_2-Al target tubes. An x-ray fluorescence cladding thickness monitor operated with a computer-controlled fluoroscope holds considerable ...

1978-01-01

204

Mapping the Spatiotemporal Dynamics of Calcium Signaling in Cellular Neural Networks Using Optical Flow  

UK PubMed Central (United Kingdom)

An optical flow gradient algorithm was applied to spontaneously forming networks of neurons and glia in culture imaged by fluorescence optical microscopy in order to map functional calcium signaling...Full Text Available

2010-08-01

205

Lysozyme dimer formation on lysozyme oxidation with B./2 as studied by fluorescence evolution  

International Nuclear Information System (INIS)

Lysozyme dimers produced on oxidation of lysozyme with Br_2anion radicals in aqueous solutions exhibit a fluorescence spectrum (lambdasub(max) = 400 nm) closely similar to that of bi-tyrosine. This suggests that the dimer is likely to have a tyrosine-tyrosine bond resulting from the combination of tyrosine phenoxy radicals of two lysozyme molecules. Kinetic studies on dimer formation were made by measuring time-dependent fluorescence after pulsed-electron irradiation over wide pH range. The results lead to the following conclusions. The second-order growth of the dimer fluorescence observed at pH 10.7-12.5 reflects the combination process of the lysozyme radicals, which is rate-determining in the pH range. On the other hand, the first-order growth observed at pH 6.8-10.2 is attributable to the enolization of the keto-form of the dimer. A tentative reaction scheme is proposed for the dimer formation. (author).

206

Imaging of calcium transients in skeletal muscle fibers.  

UK PubMed Central (United Kingdom)

Epifluorescence images of Ca2+ transients elicited by electrical stimulation of single skeletal muscle fibers were studied with fast imaging techniques that take advantage of the large fluorescence...Full Text Available

1991-01-01

207

Images of photoreceptors in living primate eyes using adaptive optics two-photon ophthalmoscopy  

UK PubMed Central (United Kingdom)

In vivo two-photon imaging through the pupil of the primate eye has the potential to become a useful tool for functional imaging of the retina. Two-photon excited fluorescence images...Full Text Available

208

Identification and In Vivo Characterization of NvFP-7R, a Developmentally Regulated Red Fluorescent Protein of Nematostella vectensis  

UK PubMed Central (United Kingdom)

BackgroundIn recent years, the sea anemone Nematostella vectensis has emerged as a critical model organism for comparative genomics and developmental biology. Although...Full Text Available

209

Human Lymphatic Architecture and Dynamic Transport Imaged Using Near-infrared Fluorescence12  

UK PubMed Central (United Kingdom)

BACKGROUND: Although the importance of lymphatic function is well recognized, the lack of real-time imaging modalities limits our understanding of its role in many diseases. In a phase...Full Text Available

210

Fluorimetric study of the interaction between nicotinamide adenine dinucleotide phosphate and tetracycline-europium complex and its application  

Energy Technology Data Exchange (ETDEWEB)

A new spectrofluorimetric method was developed for the determination of trace amount of nicotinamide adenine dinucleotide phosphate (NADP). Using europium (Eu{sup 3+})-tetracycline (TC) complex as a fluorescent probe, in the buffer solution of pH 7.60. NADP can remarkably enhance the fluorescence intensity of the Eu{sup 3+}-TC complex at {lambda} = 612 nm and the enhanced fluorescence intensity of Eu{sup 3+} ion is in proportion to the concentration of NADP. Optimum conditions for the determination of NADP were also investigated. The dynamic range for the determination of NADP is 4.4 x 10{sup -7} to 2.2 x 10{sup -6} mol l{sup -1} with detection limit of 6.9 x 10{sup -8} mol l{sup -1}. This method is simple, practical and relatively free interference from coexisting substances and can be successfully applied to determination of NADP in synthetic water samples and in serum samples. Moreover, the enhancement mechanisms of the ...

2005-09-06

211

Fluorescence amplified fragment length polymorphism for subtyping of genotypes of Acanthamoeba isolated from patients with keratitis  

UK PubMed Central (United Kingdom)

Background & objectives:Acanthamoeba keratitis (AK) is a painful and vision-threatening ocular infection. The differentiation of Acanthamoeba...Full Text Available

2011-01-01

212

Evaluation of Multiplexed Fluorescent Microsphere Immunoassay for Detection of Autoantibodies to Nuclear Antigens  

UK PubMed Central (United Kingdom)

Antibodies to extractable nuclear antigens (ENA) are found in a variety of collagen vascular diseases. Determining the individual specificities of these antibodies is extremely useful in establishing...Full Text Available

2004-11-01

213

Enantioselective Fluorescent Recognition of Chiral Acids by Cyclohexane-1,2-diamine-Based Bisbinaphthyl Molecules  

UK PubMed Central (United Kingdom)

The cyclohexane-1,2-diamine-based bisbinaphthyl macrocycles (S)-/(R)-5 and their cyclic and acyclic analogs are synthesized. The interactions of...Full Text Available

2007-06-22

214

Electronic absorption and emission spectra of Alq3 in solution with special attention to a delayed fluorescence  

International Nuclear Information System (INIS)

Tris(8-quinolinolato)aluminum(III) (Alq3) shows electronic absorption bands at 378, 360 (in a 1:1 mixed solvent of methanol and ethanol (ME) at 77 K), 334, 316, 300, 263, 255.8, and 233 nm in ethanol at room temperature. According to the polarized fluorescence excitation spectrum together with MO calculations, for instance, the 360 nm band is assigned to an LL CT transition (an intramolecular charge transfer transition between two ligands), and the 378 nm band to an LM/ML CT one (an intramolecular charge transfer transition between ligand and metal). Alq3 shows a broad fluorescence band peaking at around 478 nm in the ME matrix at 77 K. The emission spectrum measured with a phosphoroscope has two emission bands at 567 and 478 nm. The 567 nm band accompanies vibronic bands at 578 and 605 nm, being safely assigned to a phosphorescence of Alq3. The lifetimes of the 478 and 567 nm bands are both 5.4 ms. The lifetime of the 478 nm band together with ...

2008-08-01

215

Dual-channel imaging system for singlet oxygen and photosensitizer for PDT  

UK PubMed Central (United Kingdom)

A two-channel optical system has been developed to provide spatially resolved simultaneous imaging of singlet molecular oxygen (1O2) phosphorescence and photosensitizer (PS) fluorescence...Full Text Available

216

Drug-binding properties of human alpha-foetoprotein.  

UK PubMed Central (United Kingdom)

The drug-binding properties of human alpha-foetoprotein (alpha FP) were investigated by a fluorescence-spectral method. Human alpha FP was shown to bind to albumin's site I marker (warfarin, phenylbutazone),...Full Text Available

1985-10-01

217

Distance-dependent interactions between gold nanoparticles and fluorescent molecules with DNA as tunable spacers  

International Nuclear Information System (INIS)

Using stoichiometrically controlled 1:1 functionalization of gold nanoparticles with fluorescent dye molecules in which the dye molecule is held away from the particle surface by a rigid DNA spacer allows precise determination of the distance-dependent effect of the metal nanoparticles on fluorescence intensity. Two dyes were studied, Cy3 and Cy5, with two sizes of nanoparticles, 5 and 10 nm. The larger the particle, the more quenching of the photoluminescence (PL) intensity, due to increased overlap of the dye's emission spectrum with the Au surface plasmon resonance. Fluorescence is quenched significantly for distances somewhat larger than the particle diameter, in good agreement with the predictions of an electrodynamics model based on interacting dipoles. The distance dependence of surface energy transfer behavior, i.e. quenching efficiency, is proportional to 1/d4, which involves no consideration of the size of the ...

2009-12-02

218

Determination of trace elements in Syrian medicinal plants and their infusions by energy dispersive X-ray fluorescence and total reflection X-ray fluorescence spectrometry  

Energy Technology Data Exchange (ETDEWEB)

X-ray fluorescence (XRF) and total-reflection X-ray fluorescence (TXRF) techniques suited well for a multi-element determination of K, Ca, Mn, Fe, Cu, Zn, Rb, and Sr in some Syrian medicinal plant species. The accuracy and the precision of both techniques were verified by analyzing the Standard Reference Materials (SRM) peach-1547 and apple leaves-1515. A good agreement between the measured concentrations of the previously mentioned elements and the certified values were obtained with errors less than 10.7% for TXRF and 15.8% for XRF. The determination of Br was acceptable only by XRF with an error less than 24%. Furthermore, the XRF method showed a very good applicability for the determination of K, Ca, Mn, Fe, Cu, Zn, Rb, Sr, and Br in infusions of different Syrian medicinal plant species, namely anise (Anisum vulgare), licorice root (Glycyrrhiza glabra), and white wormwood (Artemisia herba-alba)

2009-07-15

220

Determination of heptacaine hydrochloride in solution using nuclear analytical methods  

Energy Technology Data Exchange (ETDEWEB)

The applicability of two nuclear analytical methods: radionuclide X-ray fluorescence analysis and radiometric titrations based on precipitate formations was studied in order to determine the heptacaine hydrochloride in solutions. The applied methods were evaluated based on the obtained sensitivity values.

1984-01-20

221

Determination of heptacaine hydrochloride in solution using nuclear analytical methods  

International Nuclear Information System (INIS)

The applicability of two nuclear analytical methods: radionuclide X-ray fluorescence analysis and radiometric titrations based on precipitate formations was studied in order to determine the heptacaine hydrochloride in solutions. The applied methods were evaluated based on the obtained sensitivity values. (author).

1984-01-01

222

Comprehensive molecular cytogenetic analysis of sorghum genome architecture: distribution of euchromatin, ...  

Science.gov (United States)

Cyteogenetic maps of sorghum chromosomes 3-7, 9, and 10 were constructed on the basis of the fluorescence in situ hybridization (FISH) of ~ ... regions of heterchromatin were delimited for all 10 sorghum chrom...

223

Compact Image Slicing Spectrometer (ISS) for hyperspectral fluorescence microscopy  

UK PubMed Central (United Kingdom)

An image slicing spectrometer (ISS) for microscopy applications is presented. Its principle is based on the redirecting of image zones by specially organized thin mirrors within a custom fabricated...Full Text Available

2009-07-20

224

Calcium gradients and buffers in bovine chromaffin cells.  

UK PubMed Central (United Kingdom)

1. Digital imaging and photometry were used in conjunction with the fluorescent Ca2+ indicator, Fura-2, to examine intracellular Ca2+ signals produced by depolarization of single adrenal chromaffin...Full Text Available

1992-05-01

225

Analyzing the Light Energy Distribution in the Photosynthetic Apparatus of C4 Plants Using Highly Purified Mesophyll and Bundle-Sheath Thylakoids.  

UK PubMed Central (United Kingdom)

The chlorophyll fluorescence characteristics of mesophyll and bundle-sheath thylakoids from plant species with the C4 dicarboxylic acid pathway of photosynthesis were investigated using flow cytometry....Full Text Available

1996-11-01

226

A post-labeling method for multiplexed and multicolored genotyping analysis of SSR, indel and SNP markers in single tube with bar-coded split tag (BStag)  

UK PubMed Central (United Kingdom)

BackgroundGenotyping analysis using capillary DNA sequencing with fluorescently labeled primer pairs obtained by polymerase chain reaction (PCR) is widely used, but is expensive....Full Text Available

227

A Software System for Data Analysis in Automated DNA?Sequencing  

UK PubMed Central (United Kingdom)

Software for gel image analysis and base-calling in fluorescence-based sequencing consisting of two primary programs, BaseFinder and GelImager, is described. BaseFinder is a framework for trace processing,...Full Text Available

1998-06-01

228

Zinc determination in medicinal powders by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

X-ray fluorescence analysis was used to determine the zinc content of the ''Perilacin'' powder and the ZnO content of the ''Epiderman-pix'' powder. The characteristic Ksub(#alpha#) line of zinc was excited using a "1"4"7Pm/Mo source (10"7 s"-"1) and the molybdenum Ksub(#alpha#) line (17.47 keV). 4 to 5% Zn and 45 to 49% ZnO were determined with a NaI(Tl) scintillation detector. The radiation intensity was found to decrease with particle size. (M.K.).

1977-01-01

229

Use of X-ray fluorescence analysis in the study of archeological samples  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis (XFA) was used in the determination of the contents of metal residues in dosing plates for coin minting. XFA was also used for the determination of the strontium/calcium ratio in bone samples of different animals with the aim to obtain information on the food composition of these animals. It was found that bones of different animals can be distinguished based on the Sr/Ca ratio. No significant differences in the Sr/Ca ratio were observed in human bones of individuals from different social groups. (author). 1 fig., 5 tabs., 4 refs.

1988-09-26

230

The use of x-ray fluorescence in the detection of inorganic elements in medicines drugs  

International Nuclear Information System (INIS)

Based on the instrumental wavelength dispersive X-ray fluorescence technique of analysis (W D-X R F), the inorganic elements in four samples of commercial medicines drugs were analyzed. The samples were used without any chemical separation of the elements or chemical pre-treatment. Eleven elements could be identified, namely Si, P, S, Cl, K, Ca, Ti, Mn, Fe, Cu and Zn. However, Si, Ti and Mn have not been mentioned in the printed instructions for the use of the medicines drugs by the producers. (author)

231

Plasma-edge studies in ISX-B and EBT-S using surface probes and laser-induced fluorescence  

Energy Technology Data Exchange (ETDEWEB)

Surface probe and laser-induced fluorescence measurements in ISX-B and EBT-S have made significant contributions to the understanding of plasma edge characteristics and plasma-surface interactions in these devices. Where comparison is possible, these techniques have led to results which are consistent with plasma diagnostics. Charge-exchange neutral sputtering and self-ion sputtering have been identified as the dominent heavy impurity release mechanisms in ISX-B and EBT-S, respectively.

1982-08-01

232

Multielement analysis of air samples  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A "2"3"8Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed. (author).

1981-01-01

233

Measurement of M shell X-ray production cross sections and fluorescence yields for the elements in the atomic range 70#<=#Z#<=#92 at 5.96 keV  

International Nuclear Information System (INIS)

Total M X-ray cross sections for 12 elements in atomic range 70#<=#Z#<=#92 were measured at 5.96 keV Mn K X-ray photon energy. The average M shell fluorescence yields (anti #omega#_M) of these elements have also been observed using the presently measured cross section values and the theoretical M shell photoionisation cross section values. (orig.).

234

Inner-shell excitation of intrinsic luminescence and resonantly excited X-ray fluorescence at Be 1s edge in oriented BeO crystals  

International Nuclear Information System (INIS)

The results of studies of the time-resolved luminescence of self-trapped excitons (STE) with different multiplicity as well as the X-ray emission in oriented BeO crystals under excitation in the vicinity of the 1 s Be photoabsorption edge are presented. The branching of the electronic excitations relaxation depends strongly on the crystal orientation after the inner-shell excitation. The common features between the processes of the STE luminescence and resonantly excited X-ray fluorescence have been discussed.

2007-05-21

235

Identification of elements in plant drugs and their water infusion using X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The present work gives preliminary results of analysis of drug mixtures (NEPHROSAL tea bag) and its water infusion. In a sample of dried drugs the elements K, Ca, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, Pb were identified, whereas in their water infusion only Ca, Mn, Zn and Sr were found. The method applied was radionuclide X-ray fluorescence analysis using a radionuclide source "1"0"9Cd, a Si/Li semiconductor detector and a multichannel analyzer Canberra 8100. (author) 6 refs.; 3 figs.

8100-01-01

236

Fluorescence resonance energy transfer using lanthanide-ion doped oxide nanoparticles as donors  

Science.gov (United States)

We have demonstrated fluorescence resonance energy transfer (FRET) between lanthanide-ion doped oxide nanoparticles acting as donors and organic acceptor molecules (Cy5). Due to the long nanoparticle lifetime and the large Stokes shift between nanoparticle absorption and emission, unambiguous and precise FRET measurements can be performed despite the presence of large free acceptor oncentrations. We determined FRET efficiencies as a function of Cy5 concentration which are in very good agreement with a multiple acceptor-multiple donor calculation.

2006-03-01

237

Diagnosing hepatocellular carcinoma with the intensity and the lifetime of two-photon red autofluorescences  

Science.gov (United States)

We demonstrated that the intensity levels and lifetimes of two-photon autofluorescences (2PAF) in human liver tissues can be exploited to diagnose hepatocellular carcinoma (HCC). Excited by an infrared femtosecond laser, we suppressed the two-photon autofluorescences of most endogenous fluorophores and made red autofluorescences more specific to particular molecules in the cryo-sectioned human livers. Using such fluorescence contrast, we found HCC tissues have reduced levels of 2PAF and longer fluorescence lifetime.

2011-02-01

238

Determination of concentration distribution of admixtures by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

A theoretical analysis is presented for the method of determining the concentration distribution of admixtures in zone melting and in the study of diffusion in melts. Continuous mode X-ray fluorescence analysis is considered. The convolution integral interpreting the analog output of the ratemeter was solved applying the mathematical apparatus of Z transformation. The feasibility of the method is tested on an example of the determination of tin distribution in tungsten. With respect to the statistical error (#delta#<1.5%), the maximum integration constant (100 s) and a very slow sample feed (0.025 mm/s) were used. The calculated transfer function reflects the total transfer function of the ratemeter and the recorder used. (M.D.).

1985-01-01

239

Determination of Mn, Fe, Cu, Zn, and Pb in particulate matter, raw and final materials of a brick factory by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence method with a Si/Li semiconductor detector and "2"3"8Pu exciting source was used in the study of Mn, Fe, Cu, Zn, and Pb content of solid emissions, raw and final materials of a brick factory. From the point of view of metal content, the working environment if the brick factory is safe for workers. (author) 2 refs.; 2 figs.; 1 tab.

1994-01-01

240

Visualization and measurement of refrigerant flow in compression-type refrigerator by neutron radiography  

International Nuclear Information System (INIS)

The refrigerant two-phase flows in a capillary tube and a distributor used in a compression-type refrigerator were visualized by real-time neutron radiography. The thermal neutron radiography system of JRR-3M at the Japan Atomic Energy Research Institute was used. In the visualization experiments of the two-phase flow in the capillary tube of 2 mm I.D., a cooled CCD camera was used, and the axial one-dimensional distributions of void fraction were measured. For the distributor, a high sensitivity video camera with a silicone intensified target tube was used. From the visualized images, the refrigerant behaviors in the distributor were clearly shown, and the liquid fraction in each tube was measured. As a result, it was shown that the refrigerant behaviors in the distributor effected the distributing performance of the refrigerant flow.

1999-11-03

241

Two dimensional NMR and NMR relaxation studies of coal structure  

Energy Technology Data Exchange (ETDEWEB)

This report covers the progress made on the title project for the project period. Four major areas of inquiry are being pursued. Advanced solid state NMR methods are being developed to assay the distribution of the various important functional groups that determine the reactivity of coals. Special attention is being paid to methods that are compatible with the very high magic angle sample spinning rates needed for operation at the high magnetic field strengths available today. Polarization inversion methods utilizing the difference in heat capacities of small groups of spins are particularly promising. Methods combining proton-proton spin diffusion with [sup 13]C CPMAS readout are being developed to determine the connectivity of functional groups in coals in a high sensitivity relay type of experiment. Additional work is aimed at delineating the role of methyl group rotation in the proton NMR relaxation behavior of coals.

1992-11-25

242

Tris(2,2prime-bipyridyl)ruthenium(II) electrogenerated chemiluminescence sensor based on carbon nantube dispersed in sol-gel-derived titania-Nafion composite films  

British Library Electronic Table of Contents (United Kingdom)

A highly sensitive and stable tris(2,2prime-bipyridyl)ruthenium(II) (Ru(bpy)32+) electrogenerated chemiluminescence (ECL) sensor was developed based on carbon nanotube (CNT) dispersed in mesoporous composite films of sol-gel titania and perfluorosulfonated ionomer (Nafion). Single-wall (SWCNT) and multi-wall carbon nanotubes (MWCNT) can be easily dispersed in the titania-Nafion composite solution. The hydrophobic CNT in the titania-Nafion composite films coated on a glassy carbon electrode certainly increased the amount of Ru(bpy)32+ immobilized in the ECL sensor by adsorption of Ru(bpy)32+ onto CNT surface, the electrocatalytic activity towards the oxidation of hydrophobic analytes, and the electronic conductivity of the composite films. Therefore, the present ECL sensor based on the CNT-...

2006-01-01

243

The influence of heating rate on the response and trapping parameters of {alpha}-Al{sub 2}O{sub 3}:C  

Energy Technology Data Exchange (ETDEWEB)

The effects of the heating rate from 0.6 up to 50{sup o}C.s{sup -1} on the thermoluminescence of {alpha}-Al{sub 2}O{sub 3}:C are very intensive. The material rapidly loses its high sensitivity as the heating rate increases. The peak shape characteristics, peak maximum and full width at half maximum agree only qualitatively with those theoretically predicted. The trapping parameters calculated by the curve fitting method, the peak shape method, the variable heating rate method and the initial rise method, were found to decrease as the heating rate increases. The validity of the results are discussed in the framework of the kinetic models. (author).

1994-12-31

244

The influence of heating rate on the response and trapping parameters of #alpha#-Al_2O_3:C  

International Nuclear Information System (INIS)

The effects of the heating rate from 0.6 up to 50"oC.s"-"1 on the thermoluminescence of #alpha#-Al_2O_3:C are very intensive. The material rapidly loses its high sensitivity as the heating rate increases. The peak shape characteristics, peak maximum and full width at half maximum agree only qualitatively with those theoretically predicted. The trapping parameters calculated by the curve fitting method, the peak shape method, the variable heating rate method and the initial rise method, were found to decrease as the heating rate increases. The validity of the results are discussed in the framework of the kinetic models. (author).

245

Spike-train bifurcation scaling in two coupled chaotic neurons  

Energy Technology Data Exchange (ETDEWEB)

We investigate the variation of the out-of-phase periodic rhythm produced by two chaotic neurons {bold (}Hindmarsh-Rose neurons [J. L. Hindmarsh and R. M. Rose, Proc. R. Soc. London B {bold 221}, 87 (1984)]{bold )} coupled by electrical and reciprocally synaptic connections. The exploration of a two-parametric bifurcation diagram, as a function of the strength of the electrical and inhibitory coupling, reveals that the periodic rhythms associated to the limit cycles bounded by saddle-node bifurcations, undergo a strong variation as a function of small changes of electrical coupling. We found that there is a scaling law for the bifurcations of the limit cycles as a function of the strength of both couplings. From the functional point of view of this mixed typed of coupling, the small variation of electrical coupling provides a high sensitivity for period regulation inside the regime of out-of-phase synchronization. {copyright} {ital 1997} {ital ...

1997-03-01

246

Somatic radiation risk in different mammography techniques  

International Nuclear Information System (INIS)

By measuring organ doses with TLD at an Alderson-Rando-phantom it was tested to evaluate the somatic risk for mammographies. Similarly as the genetic risk can be expressed by the genetic significant dose, the somatic risk can be expressed by the somatic significant dose index. The measurement results of the mammography show a large deviation of almost one power of ten with dependence of the chosen technique. In conventional xeroradiography and recording technique with foilless film the somatic radiation risk is the highest. By using amplifying foils in combination with high-sensitive films it is relatively small. Unfortunately the magnitude of the somatic risk in the different mammography techniques is in the ratio reciprocal to the corresponding image quality. At the time being the most favourable technique is mammography with a soft rastering method, although the xeromammography with additional high aluminium-filtering is a further alternative with respect to ...

1981-01-01

247

Real-time imaging for neutron radiography at KURRI  

International Nuclear Information System (INIS)

For neutron radiography (NR), photographic techniques have been mainly used for many years. To observe a dynamic event and to test many samples, the real-time neutron radiography (i.e. neutron television - NTV) system has been introduced at the E-2 experimental tube of the Kyoto University Research Reactor (KUR). The NTV system has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuel, to investigation of moving objects and to neutron computed tomography (NCT). New approaches using some advanced neutron converters, a high sensitive and resolution TV camera and a high performance image processing system are being undertaken for standard indicators, visualization on air-water two-phase flow, NCT and so on. (author).

1987-07-01

248

Photodynamic therapy against cyanobacteria  

British Library Electronic Table of Contents (United Kingdom)

This study explores the use of photosensitizers and reactive oxygen species (ROS) to limit growth of cyanobacteria. We chose 12 phthalocyanines, tetraphenol porphyrine, and methylene blue as compounds producing singlet oxygen. Hydrogen peroxide was chosen as another source of ROS. These compounds were tested using algal toxicity tests in microplates on three cultures of green algae (Pseudokirchneriella subcapitata, Scenedesmus quadricauda, and Chlorella kessleri) and on three cultures of cyanobacteria (Synechococcus nidulans, Microcystis incerta, and Anabaena sp.). Results indicate that photosensitizers and singlet oxygen could be highly toxic for some selected phytoplankton species. Green alga Scenedesmus quadricauda was highly sensitive (EC50 = 0.07 mg/L) to compounds producing singlet o...

2007-01-01

249

PET and MRI in cardiac imaging: from validation studies to integrated applications  

International Nuclear Information System (INIS)

Positron emission tomography (PET) is the gold standard for non-invasive assessment of myocardial viability and allows accurate detection of coronary artery disease by assessment of myocardial perfusion. Magnetic resonance imaging (MRI) provides high resolution anatomical images that allow accurate evaluation of ventricular structure and function together with detection of myocardial infarction. Potential hybrid PET/MR tomography may potentially facilitate the combination of information from these imaging modalities in cardiology. Furthermore, the combination of anatomical MRI images with the high sensitivity of PET for detecting molecular targets may extent the application of these modalities to the characterization of atherosclerotic plaques and to the evaluation of angiogenetic or stem cell therapies, for example. This article reviews studies using MRI and PET in parallel to compare their performance in cardiac applications together with the ...

2009-03-01

250

Oil-filled cable surveillance system using newly developed optical fiber gas sensor  

Energy Technology Data Exchange (ETDEWEB)

A new surveillance system for Oil-Filled cable, which can provide continuous monitoring, using a newly developed optical gas sensor that can detect the concentration of the gas dissolved in the oil with extremely high sensitivity has been developed. It was proved that the degree of deterioration of the insulating oil can be detected by measuring C{sub 2}H{sub 2} and CH{sub 4} by investigating the relation between the degree of deterioration and amount of combustible gas generated. In order to detect extremely small amounts of gas, a new gas detecting method using absorption line of the gas using a frequency modulated technique has been developed. The gas detection ability was also confirmed by examination using a 66 kV of cable and the possibility of detection at an early stage is expected.

1996-04-01

251

NURE aerial gamma-ray and magnetic reconnaissance survey: southeastern area-Alaska Quadrangles. Volume I. Narrative report  

International Nuclear Information System (INIS)

A rotary-wing, reconnaissance high sensitivity radiometric and magnetic survey covering the Alaska portion of twenty-nine 1:250,000 UTMS quadrangles. A total of 21,409 line miles (34,455 line kilometers) of data were collected during the 1976 and 1977 flying seasons. This report covers only the Southeastern area comprised of the Skagway, Atlin, Mt. Fairweather, Juneau, Taku River, Sitka, Port Alexander, Sumdum, Petersburg, Bradfield Canal, Craig, Dixon Entrance, Ketchikan, and Prince Rupert NTMS 1:250,000 scale quadrangles which were flown during the 1976 and 1977 seasons. The radiometric data were normalized to 400 feet terrain clearance. The data are presented in the form of computer listings on microfiche and as stacked profile plots. A geologic interpretation of the radiometric and magnetic data is included in this volume.

252

Layer-by-layer assembly of functional silica and Au nanoparticles for fabricating electrogenerated chemiluminescence sensor  

Energy Technology Data Exchange (ETDEWEB)

We described the use of silica nanoparticles as building blocks for the immobilization of electrogenerated chemiluminescence (ECL) reagent Ru(bpy){sub 3}{sup 2+} and the fabrication of layer-by-layer assembly film by alternating the deposition of the Ru(bpy){sub 3}{sup 2+}-doped silica nanoparticles and Au nanoparticles. UV-vis absorption spectroscopy, scanning electron microscopy (SEM), cyclic voltammetry and ECL were used to characterize the uniform growth of the multilayer film. Since Ru(bpy){sub 3}{sup 2+} could still maintain its ECL property when doped into the silica nanoparticles, the as-prepared multilayer film could be used as an effective ECL sensor, and the sensor showed high sensitivity and good stability.

2008-09-20

253

Layer-by-layer assembly of functional silica and Au nanoparticles for fabricating electrogenerated chemiluminescence sensor  

International Nuclear Information System (INIS)

We described the use of silica nanoparticles as building blocks for the immobilization of electrogenerated chemiluminescence (ECL) reagent Ru(bpy)_3"2"+ and the fabrication of layer-by-layer assembly film by alternating the deposition of the Ru(bpy)_3"2"+-doped silica nanoparticles and Au nanoparticles. UV-vis absorption spectroscopy, scanning electron microscopy (SEM), cyclic voltammetry and ECL were used to characterize the uniform growth of the multilayer film. Since Ru(bpy)_3"2"+ could still maintain its ECL property when doped into the silica nanoparticles, the as-prepared multilayer film could be used as an effective ECL sensor, and the sensor showed high sensitivity and good stability.

2008-09-20

254

Layer-by-layer assembly of functional silica and Au nanoparticles for fabricating electrogenerated chemiluminescence sensor  

British Library Electronic Table of Contents (United Kingdom)

We described the use of silica nanoparticles as building blocks for the immobilization of electrogenerated chemiluminescence (ECL) reagent Ru(bpy)32+ and the fabrication of layer-by-layer assembly film by alternating the deposition of the Ru(bpy)32+-doped silica nanoparticles and Au nanoparticles. UV-vis absorption spectroscopy, scanning electron microscopy (SEM), cyclic voltammetry and ECL were used to characterize the uniform growth of the multilayer film. Since Ru(bpy)32+ could still maintain its ECL property when doped into the silica nanoparticles, the as-prepared multilayer film could be used as an effective ECL sensor, and the sensor showed high sensitivity and good stability.

2008-01-01

255

Large scintillation cells for high sensitivity radon concentration measurements  

Energy Technology Data Exchange (ETDEWEB)

Methods for improving the sensitivity of scintillation cells for radon concentration measurements were studied with emphasis on improving light collection efficiency. This allows the length and hence the volume of the cell to be increased. Variables studied were choice of scintillator material, its method of application and thickness, length of cell, cell material, type and configuration of reflectors, choice of photomultipliers, and factors affecting background. Response from various areas of the cell surface was studied with an alpha source and with radon filling. Coating the window with phosphor was found to be counter-productive. The optimum results obtained were with the inside of the cell (other than the window) covered with a thick layer of ZnS(Ag), or with a thick layer of reflective material coated with a thin layer of phosphor. With it, a 10 cm diameter plexiglass cell can be extended to at least 50 cm length without difficulty from insufficient pulse height.

1983-07-01

256

Large scintillation cells for high sensitivity radon concentration measurements  

International Nuclear Information System (INIS)

Methods for improving the sensitivity of scintillation cells for radon concentration measurements were studied with emphasis on improving light collection efficiency. This allows the length and hence the volume of the cell to be increased. Variables studied were choice of scintillator material, its method of application and thickness, length of cell, cell material, type and configuration of reflectors, choice of photomultipliers, and factors affecting background. Response from various areas of the cell surface was studied with an alphy source and with radon filling. Coating the window with phosphor was found to be counter-productive. The optimum results obtained were with the inside of the cell (other than the window) covered with a thick layer of ZnS(Ag), or with a thick layer of reflective material coated with a thin layer of phosphor. With it, a 10 cm diameter plexiglass cell can be extended to at least 50 cm length without difficulty from insufficient pulse height. (orig.).

257

Integrated knowledge management in networks; Integriertes Wissensmanagement in Netzwerken  

Energy Technology Data Exchange (ETDEWEB)

Knowledge is a success factor for globally acting company networks as a. o. the aim-oriented knowledge transfer between partners is an essential condition for a successful cooperation. Several network specific problems impede however an efficient and effective knowledge management; e.g. the transfer of competition relevant data is a high sensitive theme. The authors describe how a relevant method can be selected, adapted and implemented to the application-specific boundary conditions. They integrate existing attempts processes and methods to establish an effective knowledge development and an efficient knowledge transfer in the network and take into account ''hard'' (IT-technical-oriented solution approaches) as also ''soft'' factors (e.g. cultural and personal aspects). So the authors present unified instruments for an integrated knowledge management in networks. (GL)

2007-07-01

258

Imaging of gastrinomas by nuclear medicine methods  

International Nuclear Information System (INIS)

Somatostatin receptor scintigraphy (SRS) is a valuable method for the detection of somatostatin receptor-positive lesions. Most gastrinomas (over-)express the somatostatin receptor subtype 2 which can be targeted by In-111 labeled Octreotide. Different studies show a high sensitivity of SRS for the localization and staging of gastrinomas. SRS seems to be superior to other non-invasive imaging modalities and has been proven to significantly contribute to patient management. However, the sensitivity depends on the size and exact localization of the tumors. Smaller lesions and lesions located in the duodenum show a significantly lower sensitivity. In any case, SRS belongs to the routine imaging procedure for gastrinomas for localization and staging and can also be used for evaluation of the tumor progression. (author)

259

High temperature structural silicides  

Energy Technology Data Exchange (ETDEWEB)

Structural silicides have important high temperature applications in oxidizing and aggressive environments. Most prominent are MoSi{sub 2}-based materials, which are borderline ceramic-intermetallic compounds. MoSi{sub 2} single crystals exhibit macroscopic compressive ductility at temperatures below room temperature in some orientations. Polycrystalline MoSi{sub 2} possesses elevated temperature creep behavior which is highly sensitive to grain size. MoSi{sub 2}-Si{sub 3}N{sub 4} composites show an important combination of oxidation resistance, creep resistance, and low temperature fracture toughness. Current potential applications of MoSi{sub 2}-based materials include furnace heating elements, molten metal lances, industrial gas burners, aerospace turbine engine components, diesel engine glow plugs, and materials for glass processing.

1997-03-01

260

High sensitivity and specificity of the C6-peptide ELISA on cerebrospinal fluid in Lyme neuroborreliosis patients  

British Library Electronic Table of Contents (United Kingdom)

Abstract Lyme neuroborreliosis (LNB) is a serious but treatable disease. The diagnosis of LNB poses a challenge to clinicians, and improved tests are needed. The C6-peptide ELISA is frequently used on serum but not on cerebrospinal fluid (CSF). Data on the sensitivity of the C6-peptide ELISA in CSF in patients suffering from LNB have been conflicting. Serum-CSF pairs from 59 LNB patients, 36 Lyme non-neuroborreliosis cases, 69 infectious meningitis/encephalitis controls and 74 neurological controls were tested in a C6-peptide ELISA. With the optimal cut-off of 1.1, the sensitivity of the C6-peptide ELISA for LNB patients in CSF was 95%, and the specificity was 83% in the Lyme non-neuroborreliosis patients, 96% in the infectious controls, and 97% in the neurological controls. These results ...

2011-01-01

261

Glucose Biosensor Based on the Fabrication of Glucose Oxidase in the Bio-Inspired Polydopamine-Gold Nanoparticle Composite Film  

British Library Electronic Table of Contents (United Kingdom)

Abstract A highly efficient enzyme immobilization method has been developed for electrochemical biosensors using polydopamine films with gold nanoparticles (AuNPs) embedded. This simple enzyme fabrication method can be performed in very mild conditions and stored in a long time with high bioactivity. The fabricated amperometric glucose biosensor exhibited a high and reproducible sensitivity, wide linear dynamic range and low limit of detection (LOD) (0.1 molL-1). A low value of 1.5 mmolL-1 for the apparent Michaelis-Menten constant KappM was obtained. The high sensitivity, wide linear range, good reproducibility and stability make this biosensor a promising candidate for portable amperometric glucose biosensor.

2010-01-01

262

Electrogenerated Chemiluminescence Sensor Based on Tris(2,2prime-bipyridine)ruthenium(II)-Immobilized Natural Clay and Ionic Liquid  

British Library Electronic Table of Contents (United Kingdom)

A novel electrogenerated chemiluminescence (ECL) sensor based on natural clay and ionic liquid was fabricated. Tris(2,2prime-bipyridine)ruthenium(II) (Ru(bpy)32+) was immobilized on natural clay surface through simple adsorption. An ECL sensor was prepared by mixing Ru(bpy)32+-incorporated clay, graphite powder and an ionic liquid (1-butyl-3-methylimidazolium hexafluorophosphate) as the binder. The electrochemical behavior and ECL of the immobilized Ru(bpy)32+ was investigated. It was observed that the ECL of immobilized Ru(bpy)32+ was activated by the ionic liquid. The proposed ECL sensor showed high sensitivity to tri-n-propylamine (TPrA) and the detection limit was found to be 20 pM. In addition, the ECL sensor displayed good stability for TPrA detection and long-term storage stability.

2010-01-01

263

Dissection of the thoracic aorta - role of CT and MRT following aortic replacement  

International Nuclear Information System (INIS)

Dynamic CT and MRT were performed in 21 patients who had undergone prosthetic replacement of the aorta because of dissection of the thoracic aorta. There is no difference between MRI and dynamic CT in the demonstration of a persistent intimal flap, the formation of a thrombus and the assessment of the aortic diameter in patients who underwent surgery for thoraco-abdominal aortic dissection. MRI, however, is superior in the identification of the true and false lumen and the demonstration of the distal anastomotic site. The major advantages of MRI are that there is no need for intravenous contrast agents, that it is high sensitive to flow phenomena, and that it can demonstrate the aortic arch and the ascending aorta on sagittal oblique sections. The major disadvantages of MRI are the limited access to the patient during the procedure, and the inability to examine patients fitted with pacemakers or who are on assisted ventilation. Today, MRI is ...

264

Development of SDT sensor based eddy current probe for detection of deep fatigue cracks in multi-layer structure  

British Library Electronic Table of Contents (United Kingdom)

The detection and characterization of deeply buried fatigue damage in thick, multi-layer airframe components pose significant technical challenges to the aviation safety community. Currently, no nondestructive evaluation technique is available to reliably detect such potential damage from the exterior of the airframe, which is highly desirable in light of inspection cost as well as avoidance of structure damage. Recent technological advances in high-sensitivity magnetic sensors, i.e., spin-dependent tunneling (SDT) sensors, make it feasible to employ electromagnetic inspection techniques for deep fatigue crack inspection. In this work, we report on the development and fabrication of a low frequency eddy current probe based on a magnetically shielded SDT pickup sensor concentrically located...

2010-01-01

265

Correlation of myocardial TC-99m-MIBI perfusion SPECT with coronary angiography in Namazi hospital  

International Nuclear Information System (INIS)

Coronary heart disease is the leading cause of death specially among elderly. Coronary angiography is the best diagnostic method in the patients, but is unfortunately an invasive procedure with its inherent risks. Myocardial perfusion scan is a noninvasive and sensitive method for evaluation of Coronary artery disease and is suggested by many investigators in recent years. In this study, 64 patients who had a Tc99m-MIBI SPECT myocardial perfusion study at our department, underwent coronary angiography within 4 months. Correlation of the methods revealed that SPECT Tc99m -MIBI had a high sensitivity and specificity in our hand, which is comparable with international findings.

2004-04-27

266

Changing patterns of neuropsychological functioning in children living at high altitude above and below 4000-m: a report from the Bolivian Children Living at Altitude (BoCLA) study  

British Library Electronic Table of Contents (United Kingdom)

Abstract The brain is highly sensitive to environmental hypoxia. Little is known, however, about the neuropsychological effects of high altitude residence in the developing brain. We recently described only minor changes in processing speed in native Bolivian children and adolescents living at approximately 3700-m. However, evidence for loss of cerebral autoregulation above this altitude (4000-m) suggests a potential threshold of hypoxia severity over which neuropsychological functioning may be compromised. We conducted physiological and neuropsychological assessments in 62 Bolivian children and adolescents living at La Paz (-3700-m) and El Alto (-4100-m) in order to address this issue. Groups were equivalent in terms of age, gender, social class, schooling, parental education and genetic ...

2011-01-01

267

Automated bead-positioning system for measuring impedances of R-F cavity modes  

Energy Technology Data Exchange (ETDEWEB)

We describe a fully automated bead puller system which uses stepping motors to position the bead, and an HP-8510 network analyzer to measure the resulting frequency shifts, both devices being under computer control. Longitudinal motion of the bead is used for measurement of cavity shunt impedance. In addition, azimuthal scans at fixed longitudinal position aid in determining the multipole character of higher-order modes. High sensitivity/accuracy is made possible by measuring phase shifts at the unperturbed resonant frequencies (rather than frequency shifts themselves), thereby permitting averaging factors of > 500 with only modest increases in data acquisition time. Sample measurements will be presented. A comprehensive analysis of the experimental results is presented in an accompanying paper.

1993-05-01

268

Application of CaSO4:Dy (TLD-900) to diagnostic x-ray exposures  

International Nuclear Information System (INIS)

The properties of a new commercial thermoluminescent dosimeter, CaSO4:Dy without a LiF binder (TLD-900) was studied for low-exposure measurements in diagnostic radiology. The former TLD-900 had a LiF binder (herein referred to as ''TLD-900/LiF''). The principle features of this dosimeter are its high sensitivity to low-energy radiation and its relatively low fading which permits measurements down to less than 2.6 X 10(-8) C kg (0.1 mR) with an accuracy better than 20%. The characteristics, annealing procedures, light sensitivity, energy response, reproducibility, and fading, of TLD-900 are discussed and compared with TLD-900/LiF. When the precautions presented in this paper are used, the dosimeters can be used for the measurement of x-ray exposures.

269

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

International Nuclear Information System (INIS)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. (authors)

2008-05-01

270

Uranium isotopic assay instrument  

International Nuclear Information System (INIS)

Full text: The isotopic assay instrument under development at Pacific Northwest National Laboratory (PNNL) is capable of rapid prescreening to detect small and rare particles containing high concentrations of uranium in a heterogeneous sample. The isotopic measurement concept is based on laser vaporization of solid samples followed by sensitive isotope-specific detection using either uranium atomic fluorescence emission or uranium atomic absorbance. Both isotopes are measured concurrently, following a single ablation laser pulse using two external-cavity violet diode lasers. The simultaneous measurement of both isotopes enables the correlation of the fluorescence and absorbance signals on a shot-to-shot basis. This measurement approach demonstrated negligible channel crosstalk between isotopes. Scanning the heterogeneous samples provides high-resolution imagery of sample isotopic fluorescence and absorbance. Isotopically ...

2006-10-16

271

Quantitative dissolution of (U, Pu)O_2 MOX (0.4% to 44% PuO_2) using microwave heating technique  

International Nuclear Information System (INIS)

AFFF has fabricated the (U, Pu)O_2 mixed oxide fuels for PHWRs, BWRs, PFBRs and FBTRs. The quantitative dissolution of the fuel samples are required within time for accurate determination of uranium-plutonium in chemical quality control laboratory. This paper describes the use of microwave heating technique in quantitative dissolution of (U, Pu)O_2 MOX (from 0.4% to 44% PuO_2). (author)

2011-02-22

272

Wind and Wave Forcing of Longshore Currents Across a ...  

Science.gov (United States)

... These assumptions are quantitatively investigated by calculating tie icldti\\e inportance of ... A modified lon-shore current model is used to study the ...

1988-06-01

273

The interpretation of systematic reviews with meta-analyses: an objective or subjective process?  

UK PubMed Central (United Kingdom)

BackgroundDiscrepancies between the conclusions of different meta-analyses (quantitative syntheses of systematic reviews) are often ascribed to methodological differences. The objective...Full Text Available

274

Single photon emission tomography of the pituitary: preliminary communication.  

UK PubMed Central (United Kingdom)

A specific application of single photon emission tomography to the relative quantitation of the pituitary region is described together with the results obtained in 19 patients with pituitary adenoma...Full Text Available

1981-09-01

275

Simultaneous recognition and segmentation of cells: application in C.elegans  

UK PubMed Central (United Kingdom)

Motivation: Automatic recognition of cell identities is critical for quantitative measurement, targeting and manipulation of cells of model animals at single-cell resolution. It has been...Full Text Available

2011-10-15

276

STR Training Materials  

Science.gov (United States)

Typing Workshop": [Introductions] [Intro, DNA Basics, and Historical Perspective] [DNA Extraction] [Validation and QA/QC] [DNA Quantitation] [PCR Amplification] [STR Loci and Kits]...

2011-04-29

277

Quantitative morphology and water distribution of bronchial biopsy samples.  

UK PubMed Central (United Kingdom)

BACKGROUND: An approach to the study of the pharmacokinetics of drugs in the lung is to measure their concentrations in bronchial biopsy specimens. The main criticism of this technique is that bronchial...Full Text Available

1992-07-01

278

Quantitative investigation of the crowding effect of Hymenolepis diminuta in Rattus norvegicus  

Science.gov (United States)

This laboratory exercise demonstrates some basic principles in parasitology by using experimental studies of the relationship of Hymenolepis diminuta with its rodent host.

2000-01-01

279

Quantitative easing works: Lessons from the unique experience in Japan 2001-2006  

British Library Electronic Table of Contents (United Kingdom)

Abstract: The current financial crisis has now led most major central banks to rely on quantitative easing. The unique Japanese experience of quantitative easing is the only experience which enables us to judge this therapy's effectiveness and the timing of the exit strategy. In this paper, we provide a new empirical framework to examine the effectiveness of Japanese monetary policy during the ''lost'' decade and quantify the effect of quantitative easing on Japan's activity and prices. We combine advantages of Markov-switching VAR methodology with those of factor analysis to establish two major findings. First, we show that the decisive change in regime occurred in two steps: it crept out from late 1995 and established itself durably in February 1999. Second, we show for the first time th...

2011-01-01

280

Quantitative cerebral blood flow with Optical Coherence Tomography  

UK PubMed Central (United Kingdom)

Absolute measurements of cerebral blood flow (CBF) are an important endpoint in studies of cerebral pathophysiology. Currently no accepted method exists for in vivo longitudinal...Full Text Available

2010-02-01

281

Quantitative Spectroscopy of Photospheric-Phase Type II SN  

Science.gov (United States)

... and high-quality photospheric-phase Type II SN spectra to constrain core- collapse SN explosions, massive star evolution, and distances in the Universe ...

282

Preliminary exploration of online social support among adults with asthma  

UK PubMed Central (United Kingdom)

OBJECTIVEEvaluate the qualitative and quantitative differences between moderated and unmoderated on-line social support groups focused on asthma.DESIGNA...Full Text Available

2003-01-01

283

Prediction of Chemicals Ecotoxicity  

International Science & Technology Center (ISTC)

Computer-Aided Prediction of Chemical Ecotoxicity on the basis of Quantitative Structure-Activity Relationships with the Use of Physico-Chemical Descriptors, Including H-bond Parameters

285

Gallbladder function and dynamics of bile flow in asymptomatic gallstone disease  

UK PubMed Central (United Kingdom)

AIM: To investigate the effects of gallbladder stones on motor functions of the gallbladder and the dynamics of bile flow in asymptomatic gallstone disease.METHODS: Quantitative hepatobiliary...Full Text Available

2009-06-14

286

Fractal parameters and vascular networks: facts & artifacts  

UK PubMed Central (United Kingdom)

BackgroundSeveral fractal and non-fractal parameters have been considered for the quantitative assessment of the vascular architecture, using a variety of test specimens and of computational...Full Text Available

287

Condition Monitoring of Aircraft by Quantitative Filter Debris ...  

Science.gov (United States)

... 15- Two Sigma from Mean S..... I ..... 2 ... only a small number of engine filter debris samples ... comprehensive, but it does point out that ...

1996-04-01

288

Barriers to Initiating Depression Treatment in Primary Care Practice  

UK PubMed Central (United Kingdom)

OBJECTIVE AND DESIGNThis study used qualitative and quantitative methods to examine the reasons primary care physicians and nurses offered for their inability to initiate guideline-concordant...Full Text Available

2002-02-01

289

Apolipoproteins in rat serum and renal lymph.  

UK PubMed Central (United Kingdom)

The concentration of apolipoproteins was measured by quantitative immunoelectrophoresis in rat serum, in the lipoprotein-free ultracentrifugal fraction (density greater than 1.21) of serum, and in renal...Full Text Available

1976-05-01

290

A gravitational diffusion model without dark matter  

UK PubMed Central (United Kingdom)

In this model, without dark matter, the flat rotation curves of galaxies and the mass-to-light ratios of clusters of galaxies are described quantitatively. The hypothesis is that the agent of gravitational...Full Text Available

1998-03-31

291

{sup 252}Cf-source-driven noise analysis measurements for characterization of concrete highly enriched uranium (HEU) storage vaults  

Energy Technology Data Exchange (ETDEWEB)

The {sup 252}Cf-source-driven noise analysis method has been used in measurements for subcritical configurations of fissile systems for a variety of applications. Measurements of 25 fissile systems have been performed with a wide variety of materials and configurations. This method has been applied to measurements for (1) initial fuel loading of reactors, (2) quality assurance of reactor fuel elements, (3) fuel preparation facilities, (4) fuel processing facilities, (5) fuel storage facilities, (6) zero-power testing of reactors, and (7) verification of calculational methods for assemblies with the neutron k < l. These previous measurements, performed with a wide variety of multiplying systems, demonstrated the usefulness of the method. The high sensitivity of noise-measured parameters to small changes in fissile systems has been observed in several measurements. This high sensitivity has been ...

1993-10-01

292

[Effects of 50 to 60 Hz and of 20 to 50 kHz magnetic fields on the operation of implanted cardiac pacemakers].  

Science.gov (United States)

The effect of 50 Hz and 60 Hz (frequencies of current distribution) and 20 kHz to 50 kHz (frequencies of induction cooktop) magnetic interference on implanted pacemakers have been assessed with the present generation of device technology. Sixty patients implanted in 1998 and 1999 with dual chamber pacemakers from 9 different manufacturers were monitored with telemetry while passing through, and standing between a system of two coils. They generated a 50 Hz or a 60 Hz magnetic field at 50 microT. Then, patients used a cooktop at different power. The recordings were made with the standard setting of "medically correct" sensing parameters chosen for the patients. Then pacemakers were reprogrammed to the unipolar mode, with the highest atrial (A) and ventricular (V) sensitivity that did not induce muscular inhibition while moving. Between each exposure (50 Hz, 60 Hz or 20 kHz to 50 kHz), the pacemaker programmation was controlled. At the end of the tests, pacemakers will be reprogrammed ...

2003-04-01

293

The high-sensitive magnetic levitated electrode ionization chamber of the noncontacting type  

Energy Technology Data Exchange (ETDEWEB)

There are two types of ionization chamber using magnetically levitated electrode: one is that by Tanaka et al. and the other, by authors'. The latter lacks the sensitivity relative to the former and thereby to solve the problem, authors made an improvement so that the electrode charge could be readout by noncontact after the leviated electrode was electrified by noncontact for an interval. This new type ionization chamber made it possible to measure the quite low dose radiation with stability and high sensitivity. Actually, the electrode was suspended by the teflon thread fixed on the steel cup levitated magnetically in the ionization chamber of which wall was covered by Al and equipped with an electrostatic charger for the electrode by noncontact. After measurement, the electrode was moved in the Faraday cage placed under the chamber to readout the voltage. For operation conditions of the apparatus, observation was done on the ...

1999-09-01

294

Experimental and clinical studies on the usefulness and assessment of the angiographic images processed by a digital radiography system (FCR: Fuji Computed Tomography)  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram ...

1989-06-01

295

Experimental and clinical studies on the usefulness and assessment of the angiographic images processed by a digital radiography system (FCR: Fuji Computed Tomography)  

International Nuclear Information System (INIS)

The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram ...

1989-01-01

296

Depth Profiling of N and C in Ion Implanted ZnO and Si Using Deuterium Induced Nuclear Reaction Analysis  

International Nuclear Information System (INIS)

Nuclear Reaction Analysis (NRA) with deuteron ion beams has been used to probe for ion implanted nitrogen and carbon with high sensitivity in zinc oxide and silicon single crystals. The ion implanted N was measured using 1.4 MeV deuteron ion beams and was found to be in agreement with calculated values. The limit of detection for N in ZnO is 8x1014 ions cm-2. Raman measurements of the ion implanted samples showed three additional modes at 275, 504, and 644 cm-1 compared to the un-implanted ZnO crystals. The NRA and Raman results provided information on the N concentration, depth distribution, and structural changes that occur in dependence on the nitrogen ion fluences. The deuterium induced 12C(d,p)13C reaction was used to measure the carbon impurity/dose in ion implanted silicon. It was found that the use of a large cold shield (liquid nitrogen trap) in the ion implanter chamber greatly reduces the amount of carbon impurity on the surface of ...

2008-11-03

297

Comparison of CT and MRI in patients with tibial plateau fracture: can CT findings predict ligament tear or meniscal injury?  

Energy Technology Data Exchange (ETDEWEB)

(1) To determine the accuracy of computed tomography (CT) in the evaluation of ligament tear and avulsion in patients with tibial plateau fracture. (2) To evaluate whether the presence or severity of fracture gap and articular depression can predict meniscal injury. A fellowship-trained musculoskeletal radiologist retrospectively reviewed knee CT and MRI examinations of 41 consecutive patients presenting to a level 1 trauma center with tibial plateau fractures. Fracture gap, articular depression, ligament tear and footprint avulsions were assessed on CT examinations. The MRI studies were examined for osseous and soft tissue injuries, including meniscal tear, meniscal displacement, ligament tear, and ligament avulsion. CT demonstrated torn ligaments with 80% sensitivity and 98% specificity. Only 2% of ligaments deemed intact on careful CT evaluation had partial or complete tears on MRI. Although the degree of fracture gap and articular depression was significantly greater in patients ...

2007-02-15

298

Photovoltaic lighting for outdoor telephone booth  

Energy Technology Data Exchange (ETDEWEB)

A free standing outdoor telephone booth is provided with a photovoltaic (PV) array, one or more rechargeable storage batteries and electrical control circuit which includes a temperature compensated control for limiting the supply of electrical energy from the PV array to the rechargeable battery to avoid over charging the battery, an ambient light (solar insolation) sensing circuit for controlling the electrical lamp load, to turn the lamp ON during dark ambient and OFF during light ambient conditions. In addition, the total discharge limit of the storage battery is controlled to a safe operating limit and a means is disclosed to power a fluorescent lamp at energy conserving intensities with energy derived from the rechargeable storage battery. The lamp control circuitry is preferably constituted by a high frequency power inverter with regulated output power to energize a low wattage fluorescent lamp and to dim the ...

1984-04-03

299

Measurements of K-shell x-ray production cross sections and K to L and M-shell radiative vacancy transfer probabilities for Nd, Eu, Gd, Dy and Ho at excitation with 59.5 keV photons in an external magnetic field  

International Nuclear Information System (INIS)

The effect of the #+-# 0.75 T external magnetic field on the K_#alpha#_1, K_#alpha#_2, K_#beta#_'_1 and K_#beta#_'_2 x-ray production cross sections and radiative vacancy transfer probabilities from K-shell to L2 and L3 subshells and M-shell for ferromagnetic Nd, Gd and Dy and paramagnetic Eu and Ho have been investigated, using the 59.5 keV incident photons. K-shell fluorescence yields and K x-ray intensity ratios for these elements have been determined in the external magnetic field also. The K x-rays from different targets were detected using a high-resolution Si(Li) semiconductor detector. For B = 0, the present experimental results were compared with the experimental and theoretical data in the literature. The results show that K-shell fluorescence parameters such as photoionization cross section, fluorescence yield, radiation rates, vacancy transfer probabilities and spectral linewidth can change owing to the applied ...

2006-06-19

300

Fluorescence quantum yields and cascade-free lifetimes of state selected CO_2"+, COS"+, CS_2"+ and N_2O"+ determined by photoelectron-photon coincidence spectroccopy  

International Nuclear Information System (INIS)

The details and principles of an apparatus built for measurements of fluorescence quantum yields and cascade-free lifetimes of open-shell cations are reported. These rely on the detection of coincidences between energy selected photo-electrons and undispersed photons. The results of such measurements for CO"+_2,COS"+,CS"+_2 and N_2O"+ in selected vibrational levels of their excited states are presented. Non-unity fluorescence quantum yields are found for some vibronic levels of CO"+_2(B), COS"+(A), N_2O"+(A) and a non-exponential decay is observed for CS"+_2(B). The data yield the following values for the radiative lifetimes: CO"+_2(A) 124 +- 6 ns,CO"+_2(B) 140 +- 7 ns, COS"+(A) 550 +- 50 ns and N_2O"+(A) 240 +- 12 ns. (orig.).

1980-10-01

301

Fluorescence based molecular in vivo imaging; Fluoreszenzgestuetzte molekulare Bildgebung in vivo  

Energy Technology Data Exchange (ETDEWEB)

Molecular imaging represents a modern research area that allows the in vivo study of molecular biological process kinetics using appropriate probes and visualization methods. This methodology may be defined- apart from the contrast media injection - as non-abrasive. In order to reach an in vivo molecular process imaging as accurate as possible the effects of the used probes on the biological should not be too large. The contrast media as important part of the molecular imaging can significantly contribute to the understanding of molecular processes and to the development of tailored diagnostics and therapy. Since more than 15 years PTB is developing optic imaging systems that may be used for fluorescence based visualization of tissue phantoms, small animal models and the localization of tumors and their predecessors, and for the early recognition of inflammatory processes in clinical trials. Cellular changes occur during many diseases, thus the molecular imaging ...

2008-12-15

302

A fluorescent aminolipid from a green photosynthetic bacterium  

Energy Technology Data Exchange (ETDEWEB)

A preliminary chemical characterization is presented of phosphate-free aminolipids isolation from Chlorobium limicola f. thiosulfatophilum. The lipid contains no phosphorus, glycerol, sugar, ornithine, or lysine. Ultraviolet absorption and fluorescence spectra indicate that the amino moiety of the lipid is an aromatic heterocyclic compound. Infrared spectra indicate that the lipid is a secondary or tertiary amide, and gas chromatograhic analysis of the hydrolyzed lipid shows that for each 1100 g of lipid, 1 mol of myristic acid (C/sub 14:0/) is linked in an amide bond. Acid hydrolysis of the lipid yields two fluorescent substances, A (ninhydrine positive) and B (negative), in addition to myristic acid. Proton nuclear magnetic resonance (NMR) studies indicate that substance A contains a butyl groups attached to a conjugated ring carbon, two equivalent ethyl groups attached to one or two nitrogen atoms, and two downfield protons (8.4 ppm), ...

1983-04-12

303

Tracing Cadmium from Culture to Spikelet: Noninvasive Imaging and Quantitative Characterization of Absorption, Transport, and Accumulation of Cadmium in an Intact Rice Plant1[W][OA]  

UK PubMed Central (United Kingdom)

We characterized the absorption and short-term translocation of cadmium (Cd) in rice (Oryza sativa ‘Nipponbare’) quantitatively using serial images observed with a positron-emitting...Full Text Available

2010-04-01

304

Quantitative determination of atmospheric hydroperoxyl radical  

Energy Technology Data Exchange (ETDEWEB)

A method for the quantitative determination of atmospheric hydroperoxyl radical comprising: (a) contacting a liquid phase atmospheric sample with a chemiluminescent compound which luminesces on contact with hydroperoxyl radical; (b) determining luminescence intensity from the liquid phase atmospheric sample; and (c) comparing said luminescence intensity from the liquid phase atmospheric sample to a standard luminescence intensity for hydroperoxyl radical. An apparatus for automating the method is also included.

2007-10-23

305

Quantitation of Indoleacetic Acid Conjugates in Bean Seeds by Direct Tissue Hydrolysis 1  

UK PubMed Central (United Kingdom)

Gas chromatography-selected ion monitoring-mass spectral analysis using [13C6]indole-3-acetic acid (IAA) as an internal standard provides an effective means for quantitation of...Full Text Available

1989-06-01

306

Polymer depletion-induced slip near an interface  

Energy Technology Data Exchange (ETDEWEB)

A quantitative description is proposed for the depletion-induced slip thickness and velocity profile of a polymer solution near the wall-fluid interface in simple shear flow. The inhomogeneous polymer density profile at a flat wall is inserted into the equations of motion for the flow of a polymer solution near the flat wall. The theory is in quantitative agreement with simulation results. (letter to the editor)

2005-01-19

307

On the Field Dependent Surface Resistance Observed in Superconducting Niobium Cavities  

CERN Document Server

A quantitative description is presented of the non-linear current-voltage response in superconducting niobium cavities for accelerator application. It is based on a fit for a large sample of data from cavity tests of different kind. Trial functions for the surface resistance describing this non-linear relation are established by a least square data fit. Those trial functions yielding the best fit are quantitatively explained by basic physics.

2009-01-01

308

Mapping quantitative trait loci (QTL) in sheep. II. Meta-assembly and identification of novel QTL for milk production traits in sheep  

UK PubMed Central (United Kingdom)

An (Awassi × Merino) × Merino backcross family of 172 ewes was used to map quantitative trait loci (QTL) for different milk production traits on a framework map of 200 loci across all...Full Text Available

309

Localization of an anti-tumour monoclonal antibody in human tumour xenografts: kinetic and quantitative studies with the 791T/36 antibody  

International Nuclear Information System (INIS)

Studies have been performed with an anti-osteogenic sarcoma monoclonal antibody 791T/36 and human tumour xenografts to examine some of the quantitative and kinetic aspects of tumour localization. The influence of variations in tumour size and site and antibody dose on the extent and rate of specific antibody localization have been examined, together with the site of intratumoural deposition of the antibody. (UK).

310

An immunochemical approach to the study of DNA damage and repair  

Energy Technology Data Exchange (ETDEWEB)

The overall objective of this project is to produce antibodies to unique modified DNA bases and develop immunochemical assays to quantitate these lesions in damaged DNA. During this past year we have developed an antibody and chemical test to quantitate a basic sites in DNA and produced antibodies to the 8-oxopurines. This report discusses the detection of a basic sites in DNA and the preparation of antibodies to 8-hydroxyadenine and 8-hydroxyguanine.

1990-11-14

311

Quantitative bone scintigraphy in renal osteodystrophy  

International Nuclear Information System (INIS)

The need for noninvasive sensitive techniques for the diagnosis and follow-up of metabolic bone disease in dialysis patients has stimulated the author's interest in the efficacy of more detailed quantitative bone scintigraphy. Using hemodialysis to reduce elevated soft-tissue activity at scintigraphy, an attempt was made to assess the diagnostic sensitivity of quantitative bone scintigraphy as compared to qualitative bone scintigraphic, biochemical, radiographic and bone histologic studies. The second aim of these studies was to determine if one of the two major components of renal osteodystrophy is a major determinant for skeletal radiotracer uptake. The clinical observations on the efficacy and possible specificity of quantitative bone scintigraphy in the diagnosis and follow-up during treatment of renal osteodystrophy are presented briefly in this chapter. Thus, the use of scintigraphy for the routine detection and ...

312

X-ray fluorescence in research on Czech cultural monuments  

Energy Technology Data Exchange (ETDEWEB)

Radionuclide X-ray fluorescence analysis (RXRFA), as a non-destructive method, relatively simple and allowing measurements to be carried out in situ, is an excellent tool in research on various objects of art. A range of artefacts have been investigated by our laboratory, in part for the purposes of history of art and in part as a basis for restoration works - medieval frescoes in some Czech castles and churches, metal sculptures and objects of applied art, paints and inks of old manuscripts, paintings. Some of these are among the most valuable monuments in the Czech cultural heritage. The contribution of the results of the tests to the investigation of their 'life story' and, in some cases, to their conservation, is not negligible. Later additions and repairs can be recognised, and materials and technologies that are close to their historic counterparts can be used in restoration work.

2004-01-01

313

X-ray fluorescence in research on Czech cultural monuments  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis (RXRFA), as a non-destructive method, relatively simple and allowing measurements to be carried out in situ, is an excellent tool in research on various objects of art. A range of artefacts have been investigated by our laboratory, in part for the purposes of history of art and in part as a basis for restoration works - medieval frescoes in some Czech castles and churches, metal sculptures and objects of applied art, paints and inks of old manuscripts, paintings. Some of these are among the most valuable monuments in the Czech cultural heritage. The contribution of the results of the tests to the investigation of their 'life story' and, in some cases, to their conservation, is not negligible. Later additions and repairs can be recognised, and materials and technologies that are close to their historic counterparts can be used in restoration work.

2004-01-01

314

Unfolding analysis of the mature and unprocessed forms of Bacillus licheniformis ?-glutamyltranspeptidase  

British Library Electronic Table of Contents (United Kingdom)

Bacillus licheniformis ?-glutamyltranspeptidase (BlGGT) undergoes an autocatalytic process to generate 44.9 and 21.7?kDa subunits; however, a mutant protein (T399A) loses completely the processing ability and mainly exists as a precursor. For a comprehensive understanding of their structural features, the biophysical properties of these two proteins were investigated by circular dichroism and fluorescence spectroscopy. Tryptophan fluorescence and circular dichroism spectra were nearly identical for BlGGT and T399A, but unfolding analyses revealed that these two proteins had a different sensitivity towards temperature- and guanidine hydrochloride (GdnHCl)-induced denaturation. BlGGT and the unprocessed T399A displayed T m values of 61.4?C and 68.1?C, respectively, and thermal unfolding of b...

2011-01-01

315

Transmission nuclear resonance fluorescence measurements of "2"3"8U in thick targets  

International Nuclear Information System (INIS)

Transmission nuclear resonance fluorescence measurements were made on targets consisting of Pb and depleted U with total areal densities near 86g/cm"2. The "2"3"8U content in the targets varied from 0% to 8.5% (atom fraction). The experiment demonstrates the capability of using transmission measurements as a non-destructive technique to identify and quantify the presence of an isotope in samples with thicknesses comparable to the average thickness of a nuclear fuel assembly. The experimental data also appear to demonstrate the process of notch refilling with a predictable intensity. Comparison of measured spectra to previous backscatter "2"3"8U measurements indicates general agreement in observed excited states. Evidence of two new "2"3"8U excited states and possibly a third state have also been observed.

2011-05-15

316

Total M shell X-ray production cross sections and average fluorescence yields in 11 elements from Tm to U at photon energy of 5.96 keV  

International Nuclear Information System (INIS)

Total M shell X-ray production cross section for 11 elements with 69 #<=# Z #<=# 92 have been measured using an incident photon energy of 5.96 keV. Measurements have been performed using an "5"5Fe annular source and a Si(Li) detector. Average M shell fluorescence yield at each incident photon energy has been deduced, using the experimental total M X-ray production cross section and theoretical M shell photoionization cross section. Present experimental results are compared with other experimental and theoretical values. Reasonable agreement (to within 0.3-28%) is typically obtained between present and other experimental and theoretical values.

2005-04-01

317

The investigations on K and L X-ray fluorescence parameters of gold compounds  

British Library Electronic Table of Contents (United Kingdom)

The study aimed to determine the chemical effects on the K and L X-ray intensity ratios and the K and L X-ray production cross sections for gold compounds. The K shell fluorescence yields and L shell average yields were also investigated. The samples were excited by 59.5keV ?-rays from an 241Am annular radioactive source and 123.6keV ?-rays from a 57Co annular radioactive source. K and L X-rays emitted from samples were counted by an Ultra-LEGe detector with a resolution of 0.150keV at 5.9keV. The experimental values were compared with theoretical, the semi-empirical and other experimental values.

2010-01-01

318

Synthesis of reversible fluorescent organogel containing 2-(2prime-hydroxyphenyl)benzoxazole: fluorescence enhancement upon gelation and detecting property for nerve gas simulant  

British Library Electronic Table of Contents (United Kingdom)

A new low molecular mass organogelator 1 containing 2-(2prime-hydroxyphenyl)benzoxazole (HPB) group with long alkyl chain was synthesized by the reaction with 5-amino-2-(2prime-hydroxy-4prime-methylphenyl)benzoxazole and dodecyl isocyanate in THF at room temperature. The reversible gelation ability of 1 was investigated using a heating-cooling method in various organic solvents. The stable organogel was formed from carbon tetrachloride or from cyclohexane at the concentration as low as 0.9%. The self-assembled supramolecular gel structure formed by non-covalent bonding was confirmed with field emission-scanning electron microscope (FE-SEM) exhibiting fibril- or ribbon-shaped structure depending on the solvent used. Regarding the aggregation-induced emission enhancement (AIEE) phenomenon, t...

2010-01-01

319

Structural characterization of liposomes made of diether archaeal lipids and dipalmitoyl-L-a-phosphatidylcholine  

British Library Electronic Table of Contents (United Kingdom)

The physicochemical properties of binary lipid mixtures of diether C25,25 lipids and dipalmitoyl-L-a-phosphatidylcholine (DPPC) were studied using photon correlation, fluorescence and electron paramagnetic resonance spectroscopy, and transmission electron microscopy. These two types of lipids can be mixed at all molar ratios to form unilamellar and multilamellar liposomes. Fluorescence anisotropy of 1,6-diphenyl-1,3,5-hexatrien in mixed liposomes indicates that the abrupt changes in order parameter in the hydrophobic part of bilayer membranes made of DPPC lipids disappears with increasing mol%C25,25 lipids. Electron paramagnetic resonance spectroscopy shows that at temperatures below 50^oC, the interfacial regions of membrane bilayer of mixed liposomes is more fluid than for pure DPPC lipo...

2011-01-01

320

Spatial distribution of arsenic and heavy metals in willow roots from a contaminated floodplain soil measured by X-ray fluorescence spectroscopy  

British Library Electronic Table of Contents (United Kingdom)

Under changing redox conditions some plants create plaques at their root surface, which may affect the mobility and uptake of As and heavy metals but it is unknown to what extent this also holds true for willows in contaminated floodplain soils. Therefore, willow roots were sampled from a phytoremediation trial in the contaminated floodplain of the river Elbe (Germany), cryofixed, freeze-dried, and cross sections were mapped for the distribution of As, Ca, Cu, Fe, K, Mn, Ni, S and Zn by synchrotron based X-ray fluorescence spectroscopy. The elements Ca, Cu, Ni, S and Zn were concentrated in the aerenchymatic tissue, and not associated with Fe and Mn. Mixed Fe-Mn plaques covered the surface of the willow roots and As was accumulated in these plaques. The observed association pattern between...

2011-01-01

321

Solution state hybridization detection using time-resolved fluorescence anisotropy of quantum dot-DNA bioconjugates  

British Library Electronic Table of Contents (United Kingdom)

In this Letter, we demonstrate the application of time-resolved fluorescence anisotropy measurements to detect solution state hybridization of streptavidin conjugate (CdSe)ZnS quantum dots (QD). The study was performed on samples containing 10nM QD incubated with 800nM DNA. We show that the rotational correlation time of QD-DNA constructs increases significantly upon hybridization with values of 330ns (QD-ssDNA) and 1.3ms (QD-dsDNA), corresponding to a diameter of 14nm and 23nm respectively. The present study opens a new modality for hybridization detection using quantum dots.

2010-01-01

322

Sequential injection system for phospholipase A2 activity evaluation: Studies on liposomes using an environment-sensitive fluorescent probe  

British Library Electronic Table of Contents (United Kingdom)

This work reports the development of an automatic methodology based on the use of 1-anilinonaphthalene-8-sulfonate (ANS) as an interfacial fluorescent probe for detecting the hydrophobic environment shift around the probe, caused by the hydrolytic action of PLA2 on the liposomes. The implementation of this reaction in a sequential injection analysis (SIA) system along with the use of the mixing chambers permitted the evaluation of PLA2 activity and assessment of the inhibitory effect of the non-steroidal anti-inflammatory drugs (NSAIDs) on PLA2 activity. Several studies were performed with the aim of establishing the appropriate flow system configuration: the liposome substrate; PLA2 and ANS optimum concentrations and incubation times before and after the enzyme addition. Based on these st...

2009-01-01

323

Programmable radionuclide X-ray fluorescence multi-channel spectrometric analyzer, type 123-1  

International Nuclear Information System (INIS)

The whole equipment consists of three separate portable parts: a detector case, a microprocessor and a graphic TV monitor. Magnetic tape memory and an x-y recorder can be connected for recording the measured spectra. The analyzer contains two built-in exchangeable excitation radionuclides. Fluorescence and scattered radiation is detected using a proportional detector. The detected pulses are analyzed by a 256-channel analyzer and the results are shown on the display. The device may be used in mining laboratories, coal and ore dressing plant control rooms or in mining fields of open cast mines for quick detection of the quality of mined or dressed raw materials. (E.S.). 1 fig.

1988-01-01

324

Laser-fluorescence determination of trace uranium in hot spring water, geothermal water and tap water in Xi'an Lishan region  

International Nuclear Information System (INIS)

Using the Laser-Fluorescence technique, an investigation was made, adopting the standard mix method, on trace uranium concentrations in hot spring water and geothermal water from Lishan region, and in tap water from some major cities in Shanxi province. Totally 40 samples from 27 sites were investigated. Measurement showed that the tap water contains around 10"-"6 g/L of uranium, whose concentrations in both hot spring water and geothermal water are 10"-"5 g/L. Most of samples are at normal radioactive background level, some higher contents were determined in a few samples

2002-03-01

325

Interaction of insulin with a triblock copolymer of PEG-(fumaric-sebacic acids)-PEG: Thermodynamic and spectroscopic studies  

British Library Electronic Table of Contents (United Kingdom)

A comparative study on the interaction of (PEG-co-P(FA/SC)-co-PEG) triblock copolymer with bovine and human insulins was carried out using isothermal titration calorimetry (ITC), circular dichroism (CD), and fluorescence spectroscopy. ITC data show that the copolymer has a low affinity for both proteins, with an association constant of about 7?9?103?M ?1. Results also show that binding is enthalpically driven, and disfavored by conformational entropy. CD spectroscopy studies reveal a small increase in the helical content and a decrease in ?-structure as well as random coil in both proteins. Acrylamide quenching experiments display reduced accessibility of tyrosines, while intrinsic fluorescence spectra show lower tyrosine emission. Furthermore, thermal unfolding experiments, studied by far...

2007-01-01

326

Identification of a functional nuclear export signal in the green fluorescent protein asFP499  

International Nuclear Information System (INIS)

The green fluorescent protein (GFP) asFP499 from Anemonia sulcata is a distant homologue of the GFP from Aequorea victoria. We cloned the asFP499 gene into a mammalian expression vector and showed that this protein was expressed in the human lymphoblast cell line Ramos RA1 and in the embryonic kidney 293T cell line (HEK 293T). In HEK 293T cells, asFP499 was localized mainly in the cytoplasm, suggesting that the protein was excluded from the nucleus. We identified _1_9_4LRMEKLNI_2_0_1 as a candidate nuclear export signal in asFP499 and mutated the isoleucine at position 201 to an alanine. Unlike the wildtype form, the mutant protein was distributed throughout the cytoplasm and nucleus. This is First report of a GFP that contains a functional NES.

2006-04-21

327

Human cDNA mapping using fluorescence in situ hybridization  

Energy Technology Data Exchange (ETDEWEB)

Genetic mapping is approached using the techniques of high resolution fluorescence in situ hybridization (FISH). This technology and the results of its application are designed to rapidly generate whole genome as tool box of expressed sequence to speed the identification of human disease genes. The results of this study are intended to dovetail with and to link the results of existing technologies for creating backbone YAC and genetic maps. In the first eight months, this approach generated 60--80% of the expressed sequence map, the remainder expected to be derived through more long-term, labor-intensive, regional chromosomal gene searches or sequencing. The laboratory has made significant progress in the set-up phase, in mapping fetal and adult brain and other cDNAs, in testing a model system for directly linking genetic and physical maps using FISH with small fragments, in setting up a database, and in establishing the validity and throughput of the system.

1993-03-04

328

Determination of selected elements by radionuclide X-ray fluorescence analysis after the separation on different kinds of sorption materials  

International Nuclear Information System (INIS)

This paper aimed to the evaluation of different kinds of sorbent material preparation and to the evaluation of their characteristics at different pH conditions by X-ray fluorescence analysis. This method is suitable for identification and determination of elements in samples of different character, state and origin because it is a polycomponent, non-destructive, fast and simple analytical method. Moreover, it allows timeadvantageous and reliable measurements. This paper studies problems concerning the determination of some selected elements (Mn, Fe, Ni, Cu, Zn, Pb) in pharmaceutical samples of sodium chloride in the solid state as well as in its solution by sorption on chelating extraction membrane 3M Empore"T"M and on the strongly acidic ion-exchanger Dowex 50Wx8. Conditions for the most effective sorption of determined elements are also interpreted. (author)

2008-03-01

329

Determination of selected elements by radionuclide X-ray fluorescence analysis after the separation on different kinds of sorption materials  

British Library Electronic Table of Contents (United Kingdom)

This paper aimed to the evaluation of different kinds of sorbent material preparation and to the evaluation of their characteristics at different pH conditions by X-ray fluorescence analysis. This method is suitable for identification and determination of elements in samples of different character, state and origin because it is a polycomponent, non-destructive, fast and simple analytical method. Moreover, it allows time-advantageous and reliable measurements. This paper studies problems concerning the determination of some selected elements (Mn, Fe, Ni, Cu, Zn, Pb) in pharmaceutical samples of sodium chloride in the solid state as well as in its solution by sorption on chelating extraction membrane 3M Empore? and on the strongly acidic ion-exchanger Dowex 50Wx8. Conditions for the most ef...

2008-01-01

330

Comparison of fluorescence in situ hybridisation using peptide nucleic acid probes, Gram stain/acridine orange leukocyte cytospin and differential time to positivity methods for detection of catheter related bloodstream infection in patients after haematopoietic stem cell transplantation  

British Library Electronic Table of Contents (United Kingdom)

Abstract In 46 febrile neutropenic patients who had undergone haematopoietic stem cell transplantation, the fluorescence in situ hybridisation using peptide nucleic acid probes (PNA FISH), Gram stain/acridine orange leukocyte cytospin (Gram/AOLC), and differential time to positivity (DTP) methods were performed for detection of catheter related bloodstream infections (CRBSIs). As compared with the DTP method (which detected 11 patients with CRBSI), the PNA FISH and the Gram/AOLC methods detected ten of 11 CRBSI patients, resulting in a sensitivity, specificity, negative predictive value and positive predictive value of 91%, 100%, 97% and 100%, respectively, for the PNA FISH method as well as for the Gram/AOLC method.

2010-01-01

331

Amyloid oligomers: spectroscopic characterization of amyloidogenic protein states  

British Library Electronic Table of Contents (United Kingdom)

It is assumed that protein fibrils manifested in amyloidosis result from an aggregation reaction involving small misfolded protein sequences being in an `oligomeric' or `prefibrillar' state. This review covers recent optical spectroscopic studies of amyloid protein misfolding, oligomerization and amyloid fibril growth. Although amyloid fibrils have been studied using established protein-characterization techniques throughout the years, their oligomeric precursor states require sensitive detection in real-time. Here, fluorescent staining is commonly performed using thioflavin T and other small fluorescent molecules such as 4-(dicyanovinyl)- julolidine and 1-amino-8-naphtalene sulphonate that have high affinity to hydrophobic patches. Thus, populated oligomeric intermediates and related `pre...

2010-01-01

332

Temperature-dependent properties of semiconductor quantum dots in coherent regime; Temperaturabhaengige Eigenschaften einzelner Halbleiter-Quantenpunkte im Kohaerenten Regime  

Energy Technology Data Exchange (ETDEWEB)

Recently, the public has become aware of keywords like ''Quantum computer'' or ''Quantum cryptography''. Regarding their potential application in solid state based quantum information processing and their overall benefit in fundamental research quantum dots have gained more and more public interest. In this context, quantum dots are often referred to as ''artificial atoms'', a term subsuming their physical properties quite nicely and emphasizing the huge potential for further investigations. The basic mechanism to be considered is the theoretical model of a two-level system. A quantum dot itself represents this kind of system quite nicely, provided that only the presence or absence of a single exciton in the ground state of that structure is regarded. This concept can also be expanded to the presence of two excitons (bi-exciton). Transitions between the relevant levels can be ...

2009-10-15

333

Evaluation of Aution Max AX-4030 and 9UB Uriflet, 10PA Aution Sticks urine dipsticks in the automated urine test strip analysis.  

Science.gov (United States)

Abstract Background: Aution Max AX-4030, a test strip analyzer recently introduced to the market, represents an upgrade of the Aution Max AX-4280 widely employed for urinalysis. This new instrument model can allocate two different test strips at the same time. In the present study the two instruments have been compared together with the usage of Uriflet 9UB and the recently produced Aution Sticks 10PA urine strips, the latter presenting an additional test area for the measurement of urinary creatinine. Methods: Imprecision and correlation between instruments and strips have been evaluated for chemical-physical parameters. Accuracy was evaluated for protein, glucose and creatinine by comparing the semi-quantitative results to those obtained by quantitative methods. The well-known interference effect of high ascorbic acid levels on urine glucose test strip determination was evaluated, ascorbic acid influence was also evaluated on protein and ...

2011-09-26

334

XRF and PIXE method as trols for the element analysis of metallic glasses  

International Nuclear Information System (INIS)

The radionuclide X-ray fluorescence and particle induced X-ray emission methods were used for rapid and nondestructive analysis of metallic glasses. The methods were compared for accuracy and precision with the atomic absorption method. Some results of the analyses of Fe_xNi_8_0_-_xB_2_0 materials are briefly reviewed. The distribution of elements along the width as well as the length and a qualitative analysis of the composition of material surfaces are considered. (author).

1986-01-01

335

XRF and PIXE analysis of metallic glasses  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence and particle induced X-ray emission methods were used for a rapid and nondestructive analysis of metallic glasses. The methods are compared in accuracy and precision with the atomic absorption method. Some results of analyses of Fe_xNi_8_0_-_xB_2_0 materials are briefly reviewed. The distribution of elements along the width and length, and a qualitative analysis of the composition of material surfaces are considered. (author) 3 refs.

1987-05-01

336

Width of the 1. 836-MeV level in /sup 88/Sr  

Science.gov (United States)

Using bremsstrahlung, the resonance fluorescence yield has been measured for the 1.836-MeV 2/sup +//sub 1/ level in /sup 88/Sr. The observed yield corresponds to a level width GAMMA = 2.94 +- 0.15 meV.

1977-06-01

337

Unique Properties of Thermally Tailored Copper: Magnetically Active Regions and Anomalous X-ray Fluorescence Emissions  

UK PubMed Central (United Kingdom)

When high-purity copper (≥99.98%wt) is melted, held in its liquid state for a few hours with iterative thermal cycling, then allowed to resolidify, the ingot surface is found to have...Full Text Available

2009-12-24

338

The Effects of Surface Chemistry on the Properties of Proteins Confined in Nano-porous Materials  

Energy Technology Data Exchange (ETDEWEB)

The entrapment of proteins using the sol-gel route provides a means to retain its native properties and artificially reproduce the molecular crowding and confinement experienced by proteins in the cell allowing investigation of the physico-chemical and structural properties of biomolecules at the biotic/abiotic interface. The biomolecules are spatially separated and 'caged' in the gel structure but solutes can freely permeate the matrix. Thus, properties such as the folding of ensembles of individual molecules can be examined in the absence of aggregation effects that can occur in solution studies. Green fluorescent protein from Aequorea coerulescens was used as a model protein to examine the unfolding/re-folding properties of protein in silica gels. The recombinant protein was isolated and purified from Escherichia coli extracts by cell lysis, three-phase partitioning, dialysis, and anion exchange chromatography. The purity of the protein was ...

2007-09-01

339

Standard deviation of measurement results in x-ray fluorescence spectrometry  

International Nuclear Information System (INIS)

The standard deviation of measurement results of a given element in XRF spectrometry depends on three factors: concentration and concentration region, atomic number and matrix. The effects of these factors were investigated by an XRF instrument type ARL 72.000 for aluminium metal, bauxite-red mud and aluminium using computerized data processing. A comparison of linear and nonlinear relation between concentration and the result of XRF analysis was made for the determination of standard deviation. (R.P.).

1984-11-13

340

Spectroscopic studies of the Sm_3Ga_5O_1_2 monocrystals  

International Nuclear Information System (INIS)

The fluorescence, absorption, infrared and Raman spectra of Sm_3Ga_5O_1_2 have been investigated. The energy-level schemes in the energy range 3000-16000 cm"-"1 have been determined. The number and symmetries of the Sm_3Ga_5O_1_2 crystal normal mode have been obtained by the molecular site group analysis and their comparison with the experiment has been made.

341

Some relationships between ultraviolet light and heme-protein-induced peroxidative lipid breakdown in liposomes, as reflected by fluorescence changes: the effect of negative surface charge  

International Nuclear Information System (INIS)

The water soluble, photolabile nitrene precursor, azidonaphthalene-2,7-disulfonic acid (ANDS) was encapsulated in small unilamellar, isoelectric (egg PC) or negatively charged (egg PC + dihexadecylphosphate) liposomes. The individual and combined effects of heme-proteins and UV irradiation on the fluorescence of these vesicles under aerobic conditions were studied. Consistent with the catalytic action of heme-proteins on lipid peroxidation and peroxide decomposition, addition of cytochrome c (positively charged) or catalase (negatively charged) to the vesicles elicited immediate formation of a fluorescence band at 470 nm, characteristic of Schiff bases that form from aldehyde byproducts of decomposing hydroperoxides. Ultraviolet irradiation of liposomes caused no significant changes in the fluorescence spectrum, in spite of the radiolysis of ANDS inside the vesicles with consequent formation of nitrene radicals. When ...

342

Some optimization measurements and parameters of a radionuclide X-ray fluorescence spectrometer  

International Nuclear Information System (INIS)

An irradiation head with sample holders is described and measurement geometry is reported. Measurements were made for optimizing the distance between the source and the sample and for optimizing the sample diameter. The optimal distance between the source and the sample does not depend on the collimator diameter. The sample diameter should not exceed 30 - 35 mm. Sensitivity and detection limits were determined for Zn, Pb and Br and calibration curves were plotted. (M.D.) 6 figs., 2 tabs., 4 refs.

1986-01-01

343

Remote measurement of methane in coal mines: a review  

Energy Technology Data Exchange (ETDEWEB)

The authors identify a need for a device which can remotely measure methane in coal mines. Similar techniques which have been used to measure atmospheric pollutants are discussed. These techniques include adsorption, Raman scattering and fluorescence. While differential adsorption and Raman scattering techniques have potential there are a number of problems to be resolved before they could be applied effectively. It is felt that an area which may provide suitable technology sometime in the future is in the field of laser sources. 6 refs., 4 tabs.

1987-02-01

344

Radionuclide X-ray fluorescence analysis of drinking water using preconcentration of trace metals on chelating cellulose exchanger ostsorb-oxin  

International Nuclear Information System (INIS)

Determination of Cr, Fe, Cu, Zn and Pb in drinking water preconcentrated on a chelating ion exchanger of Czechoslovak production is described. The analytical system consisted of a radionuclide source "2"3"8Pu, a Si/Li semiconductor detector and a multichannel analyzer. Results are compared with trehshold limit values recommended for drinking water. (author) 9 refs.; 2 figs.

1992-04-01

345

Radioanalytical chemistry. Vol. 2  

International Nuclear Information System (INIS)

This volume of the monograph covers the following topics: activation analysis, non-activation interaction analysis (elastic scattering of charged particles, absorption and backscattering of beta radiation and photons, radionuclide X-ray fluorescence analysis, thermalization, scattering and absorption of neutrons, use of ionization caused by nuclear radiation, use of ionization by alpha or beta radiation for the measurement of pressure, density and flow rate of gases), and automation in radioanalytical chemistry. (P.A.).

1989-01-01

346

Photoexcitation and optical pumping in a barium atomic beam  

International Nuclear Information System (INIS)

An apparatus allowing the photoexcitation of barium atomic beam over its whole surface is described. This photoexcitation is achieved by another barium spectrum emitted up steam of the beam by a cathodic out-flow produced at the exit oven. The fluorescence spectrum is studied in detail as well as the influence of different parameters, such as oven temperature, current intensity of the outflow, and excitation depth. A calculation shows how to determine Einstein coefficient, oscillator strengths and atomic lifetimes from our experimental measurements.

347

Near-Infrared Fluorescence Labeled Anti-TAG-72 Monoclonal Antibodies for Tumor Imaging in Colorectal Cancer Xenograft Mice  

UK PubMed Central (United Kingdom)

Anti-TAG-72 monoclonal antibodies target the tumor-associated glycoprotein (TAG)-72 in various solid tumors. This study evaluated the use of anti-TAG-72 monoclonal antibodies, both murine CC49...Full Text Available

2009-01-01

348

Measurement of time of travel in streams by dye tracing  

Energy Technology Data Exchange (ETDEWEB)

The US Geological survey is active in measuring time of travel in streams using dye tracers. This manual describes methods of measuring time of travel of water and waterborne solutes by dye tracing. The fluorescent dyes, measuring equipment used, and field and laboratory procedures are also described. Methods of analysis and presentation to illustrate time of travel of streams are provided.

1989-01-01

349

Measurement of K x-ray intensity ratio of tin, gadolinium and dysprosium  

International Nuclear Information System (INIS)

Full text: Measurement of K_#beta# to K_#alpha# x-ray intensity ratios are important not only in the field of atomic physics, radiation physics and medical physics, but also to test the validity of assumptions made in the theoretical prediction. The intensity ratios can also give information on the effect of physical and chemical environment of the element in the compound. Many investigators have adopted a single and double reflection geometries to measure the K_#beta# to K_#alpha# x ray intensity ratios to understand the effect of physical and chemical environment on x-ray fluorescence. The targets are excited by a radioactive source of having activity of the order 100 MBq. in order to carry out accurate measurement K_#beta# to K_#alpha# x-ray intensity ratios, we have develop 2#pi# geometrical configuration method : placing a target right on the surface of the detector facing the target to measure the K shell fluorescence parameters such as ...

2003-11-01

350

Laser-induced fluorescence measurement of sup(6,7)lithium isotope shift  

Energy Technology Data Exchange (ETDEWEB)

Values of frequency splittings in the lithium isotopes have been determined with the aid of laser-induced fluorescene in a supersonic beam, perpendicularly irradiated by a CW ring dye laser. The residual 2s-2p isotope shift has been found to bw 4721.8 +- 2.0 MHz, leading to a specific mass shift for the 2p level of -3610.8 +- 5 MHz.

1986-07-01

351

Identification and determination of elements in Taraxacum officinale plant from different Bratislava localities  

Energy Technology Data Exchange (ETDEWEB)

Elements Ti, Mn, Fe, Ni, Cu, Zn, Pb, Br, Rb and Sr were determined by the method of radionuclide X-ray fluorescence analysis with semiconductor detection in samples of Taraxacum officinale from various localities of Bratislava. The dependence of their content on the source and the degree of the air pollution was found out.

1983-01-01

352

Identification and determination of elements in Taraxacum officinale plant from different Bratislava localities  

International Nuclear Information System (INIS)

Elements Ti, Mn, Fe, Ni, Cu, Zn, Pb, Br, Rb and Sr were determined by the method of radionuclide X-ray fluorescence analysis with semiconductor detection in samples of Taraxacum officinale from various localities of Bratislava. The dependence of their content on the source and the degree of the air pollution was found out. (author).

1983-01-01

353

Heavy metals in welding fumes  

Energy Technology Data Exchange (ETDEWEB)

Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A /sup 241/Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer.

1984-10-01

354

Heavy metals in welding fumes  

International Nuclear Information System (INIS)

Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A "2"4"1Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer. (E.S.).

1984-01-01

355

Fusion of GFP to the M.EcoKI DNA methyltransferase produces a new probe of Type I DNA restriction and modification enzymes  

UK PubMed Central (United Kingdom)

AbstractWe describe the fusion of enhanced green fluorescent protein to the C-terminus of the HsdS DNA sequence-specificity subunit of the Type I DNA modification methyltransferase M.EcoKI....Full Text Available

2010-07-23

356

Effect of Elicitation and Changes in Extracellular pH on the Cytoplasmic and Vacuolar pH of Suspension-Cultured Soybean Cells 1  

UK PubMed Central (United Kingdom)

We have employed both 31P nuclear magnetic resonance spectroscopy and two intracellular fluorescent pH indicator dyes to monitor the pH of the vacuole and cytoplasm of suspension-cultured...Full Text Available

1992-02-01

357

Determination of the Sr/Ca ratio in bones by XRFA  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis was used for the determination of Sr/Ca ratio in bones to test the influence of a diet on this ratio. Significant differences were observed for Sr/Ca ratio in bones of various animals. Only small differences in the Ca/Sr ratio were observed for the samples of various prehistoric human bones. (author) 4 refs.; 4 tabs.

1989-11-01

358

Determination of heavy metals in welders' working environment using nuclear analytical methods  

International Nuclear Information System (INIS)

Technological processes of welding are significant sources of pollution in the working area. Evaluation of chemical quality of working area was made by means of radionuclide x-ray fluorescence analysis and activation analysis with fast neutrons. Welding aerosols were sampled by filtration method on Synpor 4 membrane ultra-filters. For selected types of welding filter metals, determination of heavy metals in aerosols was performed. (author).

1985-01-01

359

Determination of heavy metals in welders' working environment using nuclear analytical methods  

Energy Technology Data Exchange (ETDEWEB)

Technological processes of welding are significant sources of pollution in the working area. Evaluation of chemical quality of working area was made by means of radionuclide x-ray fluorescence analysis and activation analysis with fast neutrons. Welding aerosols were sampled by filtration method on Synpor 4 membrane ultra-filters. For selected types of welding filter metals, determination of heavy metals in aerosols was performed.

1985-01-03

360

Determination of heavy metals in industrial wastewaters and their influence on activated sludge biocenose  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence method with a Si/Li semiconductor detector and "2"3"8Pu exciting source was used in the determination of Cr, Fe, Ni, Cu, and Zn content in industrial wastewaters. Simultaneously, the effects of the wastewaters on activated sludge biocenose were evaluated. (author) 6 refs.; 1 fig.; 1 tab.

1994-03-01

361

Determination of Mg, Al, Si, Cl and K in some medicinal plants by NAA and REA methods  

Energy Technology Data Exchange (ETDEWEB)

Trace elements have been determined in biological samples including pepperwort, thyme, plantain, blessed thistle and common comfrey as well as cabbage leaves and milk powder. Concentrations of Al, Si, and Cl have been determined by fast neutron activation analysis while, in the case of Mg-, K, and Cl the X-ray fluorescence method was used.

1982-07-26

362

Detection device for high explosives  

Energy Technology Data Exchange (ETDEWEB)

A portable fiber optic detector that senses the presence of specific target chemicals by electrostatically attracting the target chemical to an aromatic compound coating on an optical fiber. Attaching the target chemical to the coated fiber reduces the fluorescence so that a photon sensing detector records the reduced light level and activates an appropriate alarm or indicator.

1992-01-01

364

Contribution to the sample preparation in the radionuclide X-ray fluorescence analysis of hair  

International Nuclear Information System (INIS)

Methods of sample treatment in XRF analysis of hair are studied in view of the effect on analytical results. A new method is proposed based on the incomplete ashing of hair followed by pellet preparation. Its suitability is estimated on the XRF analysis of real hair samples collected from 4 healthy adults. (author) 12 refs.; 4 figs.; 1 tab.

1989-03-01

365

Application of isotope-excitation x-ray fluorescence (XRF) analysis for aluminium production  

International Nuclear Information System (INIS)

An energy sensitive Si(Li) detector XRF analyzer built by ATOMKI, Hungary, has been applied for various analytical purposes in alumina production at the Almasfuezitoe Alumina Company, Hungary. Specifically, the CaO content in red mud was determined by the new XRF technique using isotope excitation sources. The analysis of other components is under way. (R.P.).

366

Analysis of titanium and zirconium in red mud with energy dispersive x-ray spectrometry  

Energy Technology Data Exchange (ETDEWEB)

An energy dispersive x-ray fluorescence technique was used for the determination of Titanium (Ti) and Zirconium (Zr) in red mud by using a standard addition method. An annular {sup 241}Am source is employed for excitation of K shells of elements. 13 refs., 2 figs., 1 tab.

1996-11-01

367

A study of the interactions of some polypyridylruthenium (II) complexes with DNA using fluorescence spectroscopy, topoisomerisation and thermal denaturation.  

UK PubMed Central (United Kingdom)

The nature of binding of Ru(phen) 2+ (I), Ru(bipy) 2+ (II), Ru(terpy) 2+ (III) (phen = 1,10-phenanthroline, bipy 3 = 2,2'-bipyridyl, 3 terpy = 2,2'2," - 2 terpyridyl) to DNA, poly[d(G-C)] and poly[d(A-T)]...Full Text Available

1985-09-11

368

A simple system of instruments for radionuclide X-ray fluorescence analysis in nonferrous metallurgy  

International Nuclear Information System (INIS)

Proceeding from commercially available instruments, a simple measuring system has been established, which renders possible fast and simple discontinuous analysis of individual elements. This measuring system is described, giving some examples of utilization in nonferrous metallurgy (mining, ore dressing, metallurgical treatment), and specific details, such as error of measurement, ranges of measurement and limits of utilization. (author).

1979-01-01

369

Undergraduate Instruction in Empirical Research Methods in Communication: Assessment and Recommendations  

British Library Electronic Table of Contents (United Kingdom)

This study assesses the current state of undergraduate instruction in empirical research methods in communication and offers recommendations for enhancing such instruction. Responses to an online questionnaire were received from 149 communication-related programs at four-year colleges and universities. Just over 85% of responding programs offered an empirical methods course. Although the course often covered both qualitative and quantitative methods, instruction was heavily slanted toward quantitative methods and topics common to both qualitative and quantitative inquiry. The empirical methods course was usually required for graduation, but it was typically not well integrated with the rest of the curriculum and taken late in students' undergraduate careers. Additional analyses examined st...

2011-01-01

370

Quantitative bone scintigraphy: follow-up of a femoral osteogenic sarcoma in an adolescent girl treated by chemotherapy and by massive allograft  

International Nuclear Information System (INIS)

Fifteen quantitative bone scintigraphies were performed in an adolescent girl during the follow-up of a femoral osteogenic sarcoma treated by chemotherapy and massive allograft. Three hours after injection of the radiopharmaceutical (7.4 MBq/kg of 99mTc-MDP) bone activity was measured in the inferior limbs at several regions of interest centered on the hips, femurs (proximal, middle, distal) and proximal tibias. The variations of relative bone activities A/S (ratio of corresponding counting rates between two homologous regions in the affected A and in the healthy S limb) and of absolute bone activities (expressed in counts/pixel-second) are interpreted as a function of times during treatment. The quantitative results are discussed with regard to main phenomena influencing bone activity in this particular clinical case: bone growth, chemotherapy and neo-osteogenesis in allograft.

371

Quantitation of infectious myonecrosis virus in different tissues of naturally infected Pacific white shrimp, Litopenaeus vannamei, using real-time PCR with SYBR Green chemistry  

British Library Electronic Table of Contents (United Kingdom)

The Pacific white shrimp, Litopenaeus vannamei, is the most important shrimp species in volume in world aquaculture. However, in recent decades, outbreaks of diseases, especially viral diseases, have led to significant economic losses, threatening the sustainability of shrimp farming worldwide. In 2004, Brazilian shrimp farming was seriously affected by a new disease caused by the Infectious myonecrosis virus (IMNV). Thus, disease control based on rapid and sensitive pathogen detection methods has become a priority. In this study, a specific quantitation method for IMNV was developed using real-time PCR with SYBR Green chemistry and viral load of the principal target tissues of chronically infected animals was quantified. The quantitative analysis revealed that mean viral load ranged from ...

2011-01-01

372

Nuclear medicine and imaging research: Quantitative studies in radiopharmaceutical science  

Energy Technology Data Exchange (ETDEWEB)

During the past three years the program has undergone a substantial revitalization. There has been no significant change in the scientific direction of this grant, in which emphasis continues to be placed on developing new or improved methods of obtaining quantitative data from radiotracer imaging studies. However, considerable scientific progress has been made in the three areas of interest: Radiochemistry, Quantitative Methodologies, and Experimental Methods and Feasibility Studies, resulting in a sharper focus of perspective and improved integration of the overall scientific effort. Changes in Faculty and staff, including development of new collaborations, have contributed to this, as has acquisition of additional and new equipment and renovations and expansion of the core facilities. 121 refs., 30 figs., 2 tabs.

1991-06-01

373

Combining adjusted and unadjusted findings in mixed research synthesis  

British Library Electronic Table of Contents (United Kingdom)

Abstract Rationale, aims and objectives- Finding ways to incorporate disparate types of evidence into research syntheses has the potential to build a better evidence base for clinical practice and policy. Yet conducting such mixed research synthesis studies is challenging. Researchers have to determine whether and how to use adjusted and unadjusted quantitative findings in combination with each other and with qualitative findings. Methods- Among quantitative findings, adjustment for confounding, either via study design or statistical analysis, can be a considerable source of heterogeneity. Yet there is no consensus about the best way to synthesize findings resulting from different methods for addressing confounding. When synthesizing qualitative and quantitative findings, additional consid...

2011-01-01

374

Automation in urinalysis: evaluation of three urine test strip analysers.  

Science.gov (United States)

A clinical laboratory evaluation was conducted on the Clinitek Auto 2000, the Super Aution Analyzer and the Urotron RL9 for the determination of glucose, protein, pH, blood, ketone-bodies and bilirubin.Precision of the systems was tested using three commercial control urine materials, and reported as the percentage of times the instrument repeats a certain value. Good repeatability was obtained with all the instruments.Accuracy of the systems was evaluated by comparison with quantitative procedures, and to check agreement between methods yielding semi-quantitative and quantitative results, ranges of acceptability were defined, based on the criteria reported in a previous paper [2]. It was then found that 87.5 to 98.9% of results from the Urotron RL9 and the Clinitek Auto 2000 were acceptable. With the Super Aution Analyzer the level of agreement was apparently lower because of the higher number of concentration steps used ...

1988-01-01

375

{sup 252}Cf-source-driven frequency analysis measurements with subcritical arrays of PWR fuel pins  

Energy Technology Data Exchange (ETDEWEB)

Experiments with fresh PWR fuel assemblies were performed to assess the {sup 252}Cf-source-driven frequency analysis method for measuring the subcriticality of spent fuel. The measurements at the Babcox and Wilcox Critical Experiments Facility mocked up between 17x17 fuel pins (single assembly) and a full array of 4961 fuel pins (about 17 fuel assemblies) in borated water with a fixed B concentration. For the full array, the B content of the water was varied from 1511 at delayed criticality to 4303 ppM. Measurements were done for various source-detector-fuel pin configurations; they showed high sensitivity of frequency analysis parameters to B content and fissile mass. Parameters such as auto and cross power spectral densities can be calculated directly by a more general model of the Monte Carlo code (MCNP-DSP). Calculation-measurement comparisons are presented. This model permits the validation of neutron and gamma ray transport calculational ...

1996-08-01

376

Two dimensional NMR and NMR relaxation studies of coal structure. Progress report, July 1, 1992--September 30, 1992  

Energy Technology Data Exchange (ETDEWEB)

This report covers the progress made on the title project for the project period. Four major areas of inquiry are being pursued. Advanced solid state NMR methods are being developed to assay the distribution of the various important functional groups that determine the reactivity of coals. Special attention is being paid to methods that are compatible with the very high magic angle sample spinning rates needed for operation at the high magnetic field strengths available today. Polarization inversion methods utilizing the difference in heat capacities of small groups of spins are particularly promising. Methods combining proton-proton spin diffusion with {sup 13}C CPMAS readout are being developed to determine the connectivity of functional groups in coals in a high sensitivity relay type of experiment. Additional work is aimed at delineating the role of methyl group rotation in the proton NMR relaxation behavior of coals.

1992-11-25

377

The optical emission nebulae in the vicinity of WR 48 (Theta Mus); True Wolf-Rayet ejecta or unconnected supernova remnant?  

CERN Document Server

During searches for new optical Galactic supernova remnants (SNRs) in the high resolution, high sensitivity Anglo-Australian Observatory/United Kingdom Schmidt Telescope (AAO/UKST) HAlpha survey of the southern Galactic plane, we uncovered a variety of filamentary and more diffuse, extensive nebular structures in the vicinity of Wolf-Rayet (WR) star 48 (Theta Muscae), only some of which were previously recognised. We used the double-beam spectrograph of the Mount Stromlo and Siding Spring Observatory (MSSSO) 2.3-m to obtain low and mid resolution spectra of selected new filaments and structures in this region. Despite spectral similarities between the optical spectra of WR star shells and SNRs, a careful assessment of the new spectral and morphological evidence from our deep HAlpha imagery suggests that the putative shell of Theta Mus is not a WR shell at all, as has been commonly accepted, but is rather part of a more complex area of ...

2009-01-01

378

The Schenberg spherical antenna: status report  

International Nuclear Information System (INIS)

Full text. Here we present a status report of the Schenberg antenna, which started commissioning runs in September 2006 under the full support of FAPESP. In its first commissioning runs we tested three preliminary parametric transducer systems, which did not achieve a high enough performance for placing the antenna sensitivity in the range of the calibrator capacitor. Instead of improving the calibrator, making it capable of introducing a larger input force, we decided to go to a radical upgrading operation: replacing the three transducers for a complete set of six transducers, with better sensitivity and arranged according to the truncated icosahedron configuration, plus two extra ones; starting to install the dilution refrigerator; installing wires, cables, and amplifiers for the complete set of transducer circuits; and a new suspension and vibration isolation system for the cabling and microstrip antennas. We also have been developing a new set of transducers, microwave oscillators, ...

2009-09-14

379

Superconducting gravity gradiometer for sensitive gravity measurements. I. Theory  

Energy Technology Data Exchange (ETDEWEB)

Because of the equivalence principle, a global measurement is necessary to distinguish gravity from acceleration of the reference frame. A gravity gradiometer is therefore an essential instrument needed for precision tests of gravity laws and for applications in gravity survey and inertial navigation. Superconductivity and SQUID (superconducting quantum interference device) technology can be used to obtain a gravity gradiometer with very high sensitivity and stability. A superconducting gravity gradiometer has been developed for a null test of the gravitational inverse-square law and space-borne geodesy. Here we present a complete theoretical model of this instrument. Starting from dynamical equations for the device, we derive transfer functions, a common mode rejection characteristic, and an error model of the superconducting instrument. Since a gradiometer must detect a very weak differential gravity signal in the midst of large platform ...

1987-06-15

380

Sensitive detection of endocrine disrupters using ionic liquid - Single walled carbon nanotubes modified screen-printed based biosensors.  

Science.gov (United States)

Simple and low cost biosensor based on screen-printed electrode for sensitive detection of some alkylphenols was developed, by entrapment of HRP in a nanocomposite gel based on single-walled carbon nanotubes (SWCNTs) and 1-butyl-3-methylimidazolium hexafluorophosphate ([BMIM][PF(6)]) ionic liquid. Raman and FTIR spectroscopy, CV and EIS studies demonstrate the interaction between SWCNTs and ionic liquid. The nanocomposite gel, SWCNT-[BMIM][PF(6)] provides to the modified sensor a considerable enhanced electrocatalytic activity toward hydrogen peroxide reduction. The HRP based biosensor exhibits high sensitivity and good stability, allowing a detection of the alkylphenols at an applied potential of -0.2V vs. Ag/AgCl, in linear range from 5.5 to 97.7?M for 4-t-octylphenol and respectively, between 5.5 and 140?M for 4-n-nonylphenol, with a response time of about 5s. The detection limit was 1.1?M for 4-t-octylphenol, and respectively 0.4?M for ...

2011-07-19

381

Role of accelerator mass spectrometry in biological dosimetry  

International Nuclear Information System (INIS)

Understanding risks from exposures to carcinogens and other chemicals depends upon measurement of their dose to target tissues and their reactivity with critical macromolecules. The authors have used AMS detection of radio-isotopes to assess doses and reactivities at low, environmentally relevant doses. Several biomedical investigations show the effectiveness of quantification of biologically important events at extremely high sensitivity with AMS. Specifically, they have measured the addition of environmental carcinogens such as 2-amino-3,8-dimethylimidazo[4,5-f]-quinoaxaline (MelQx), a chemical found in cooked food, to DNA at concentrations relevant to human exposure. Other low level detection problems in biology, such as immunoassay assessment of small environmental chemicals, is being developed with attomole sensitivity. AMS also aids the assessment of genotoxic risks from chemicals by quantifying the binding of labeled chemicals to DNA. ...

1992-04-05

382

Radioxenons: Their role in monitoring a Comprehensive Test Ban Treaty  

Energy Technology Data Exchange (ETDEWEB)

Monitoring for xenon radionuclides which are produced in a nuclear detonation can provide a strong deterrent to the violation of a Comprehensive nuclear Test Ban Treaty (CTBT). There are 18 known radioactive xenon isotopes produced in nuclear fission with half-lives ranging from less than one second to 11.9 days. However, only four of these remain in significant amounts more than a day after a detonation. In order for radioxenon monitoring to be practical, it was necessary to develop an automated measurement system which could operate unattended for periods of months, measure the entire spectrum of radioxenons, and provide hundreds of times better sensitivities than current laboratory procedures. This capability was developed at the US Department of Energy`s Pacific Northwest National Laboratory based on rapid separation of atmospheric xenon coupled with a unique high sensitivity measurement device for the radioxenons. A fieldable prototype ...

1996-06-01

383

Preparation, characterization and electrical properties of SnO{sub 2} based liquid petroleum gas sensor  

Energy Technology Data Exchange (ETDEWEB)

The present investigation deals with the fabrication of liquid petroleum gas (LPG) sensor based on semiconducting oxide SnO{sub 2}. The gas sensor elements have been prepared by conventional solid state route. Addition of noble metal sensitizer, palladium and grain growth inhibitor, aluminum silicate to the base material SnO{sub 2}, not only improved the sensitivity towards LPG but also the selectivity in the presence of CO and CH{sub 4} gases. Out of various sensor compositions, SnO{sub 2}:Al{sub 2}Si{sub 2}O{sub 7} (35 wt.%):Pd (1.5 wt.%) sintered at 800 C for 5 h has shown high sensitivity (0.97) towards LPG at an operating temperature of 350 C. Different characterization techniques have been employed, such as differential thermal analysis (DTA), surface area analyzer, X-ray diffraction (XRD), to study the formation of SnO{sub 2}, surface area and crystallite size, respectively. The results suggested the possibility of utilizing the sensor ...

1999-03-25

384

PIXE analysis of GaAs and ZnSe  

Energy Technology Data Exchange (ETDEWEB)

The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K{sub {alpha}} X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K{sub {alpha}} X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be satisfied in order that the X-ray intensity ratios are not strongly affected by X-ray absorption; and therefore, the ...

1990-01-01

385

PIXE analysis of GaAs and ZnSe  

International Nuclear Information System (INIS)

The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K_#alpha# X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K_#alpha# X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be satisfied in order that the X-ray intensity ratios are not strongly affected by X-ray absorption; and therefore, the ...

1989-06-01

386

Measuring the quark contribution to the proton spin through. nu. p yields. nu. p  

Energy Technology Data Exchange (ETDEWEB)

The LSND (Liquid Scintillator Neutrino Detector) experiment will be performed at LAMPF in the next several years. The main goal of the experiment is to search for {nu}{sub {mu}}-{nu}{sub e} oscillations with high sensitivity; however, an increasingly important by-product of this search is to measure {nu}p {yields} {nu}p elastic scattering and determine the strange quark contribution, {Delta}s, to the spin of the proton. With the 800-MeV proton energy of LAMPF, neutrinos are produced from pion decay-in-flight with an average energy of about 150 MeV. This energy is sufficiently high so that the {nu}p {yields} {nu}p cross section is large and is sufficiently low so that the low Q{sup 2} approximation (Q{sup 2} {much lt} m{sub p}{sup 2}) is valid and the cross section can be expressed in a simple form dependent upon {Delta}s as the only unknown. LAMPF with its 1-mA proton intensity is, therefore, an ideal accelerator to perform this measurement. 12 ...

1991-01-01

387

Magnetic resonance imaging in multiple sclerosis. Imagerie nouvelle par resonance magnetique nucleaire au cours de la sclerose en plaques  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) has rapidly attained a major position among the examinations used in the diagnostic approach of multiple sclerosis because it is highly sensitive in demonstrating lesions. However, these lesional images may have several meanings, and there is the problem of distinguishing between oedema, which is said to reflect recent lesions, and gliosis which is thought to betray old lesions. The intrinsic MRI parameters studied (i.e. relaxation times) are unable to make this distinction, whereas it is provided by paramagnetic contrast media such as gadolinium. There is no correlation between the changes observed at MRI and the severity of the disease. Another problem is the accuracy of lesion localization, since visualization is predominantly macroscopic. This raises several questions about the demonstration of correlations between clinical signs and site of the lesion(s). At the moment, several teams of neuroradiologists ...

1991-09-15

388

Lymph node staging in cervical carcinoma: Results of high resolution MRT with phased-array coil  

International Nuclear Information System (INIS)

Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T_2-weighted turbo-spin-echo (TSE) and T_1-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm"2. Lymph nodes with a diameter of #>=#8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes (#>=# 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR findings were true negative (specificity 92%). Diagnostic accuracy was 91%. Conclusion: High-resolution MR imaging with a c.p. ...

389

Highly specific antiserum for arginine vasopressin  

International Nuclear Information System (INIS)

A high sensitivity (titer 60-150,000) radioimmunoassay for arginine vasopressin (AVP) has been developed using synthetic AVP as antigen and standard. The specificity of the antiserum has been characterized in detail by measuring the relative binding affinities of 29 analogs and fragments of AVP. In general, single amino acid substitution or deletion in the AVP molecule caused a reduction in binding to the antiserum; binding was further impaired for analogs which had multiple substitutions. ''Ring'' and ''tail'' fragments of the neurohypophysial hormones did not bind to the antiserum, and the only analog which the antiserum could not differentiate from AVP was deamino-AVP. More specifically, the antiserum exhibited the following properties: position 1, no requirement for a position charge at "1/_2 Cys; positions 2 and 3, requirements for #pi#-#pi# interacting pair of aromatic side chains and for Tyr at position 2; position 4, requirement for Gln ...

390

Electron momentum spectroscopy of H_2 and D_2: Ionization to ground and excited final states  

International Nuclear Information System (INIS)

The symmetric noncoplanar (e,2e) cross sections (momentum profiles) of H_2 and D_2 for the transitions to the 2p#sigma#_u and 2s#sigma#_g excited ion states have been measured, relative to the ground-state ion transition, using a high-sensitivity multichannel momentum-dispersive electron momentum spectrometer (EMS) at an impact energy of 1200 eV. Newly calculated plane-wave impulse approximation (PWIA) cross sections, based on a full-configuration-interaction H_2 wave function, are compared to the experimental results. These calculations are in better agreement with the experimental results for the transition to the 2s#sigma#_g ion state than the earlier theoretical work of Liu and Smith, Jr. [Phys. Rev. A 31, 3003 (1985)] which has been found to be in error. Nevertheless, significant discrepancies between the relative experimental and theoretical cross sections are observed for the transitions to excited ion states, suggesting a failure of the PWIA description of ...

391

Direct electrochemistry of catalase at amine-functionalized graphene/gold nanoparticles composite film for hydrogen peroxide sensor  

International Nuclear Information System (INIS)

Direct electrochemistry and electrocatalysis of catalase (Cat) was studied based on a nano-composite film consisting of amine functionalized graphene and gold nanoparticles (AuNPs) modified glassy carbon electrode. Graphene was synthesized chemically by Hummers and Offeman method and then was functionalized with amino groups via chemical modification of carboxyl groups introduced on the graphene surface. The nano-composite film showed an obvious promotion of the direct electron transfer between Cat and the underlying electrode, which attributed to the synergistic effect of graphene-NH2 and AuNPs. The resultant bioelectrode retained its biocatalytic activity and offered fast and sensitive H2O2 quantification. Under the optimized experimental conditions, hydrogen peroxide was detected in the concentration range from 0.3 to 600 ?M with a detection limit of 50 nM at S/N = 3. The biosensor exhibited some advantages, such as short time respond (2 s), high ...

2011-02-28

392

Diagnostic Performance of Computed Tomography Colonography in Symptomatic Patients and in Patients with Increased Risk for Colorectal Disease  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate the diagnostic performance (colorectal lesions) of computed tomography (CT) colonography in 111 patients, a majority of whom were at high risk for colorectal neoplasia. Material and Methods: After bowel preparation, CT colonography was performed, immediately followed by conventional colonoscopy. The diagnostic performance of CT colonography was analyzed relative to lesion size, histological diagnosis, and diagnostic certainty. Results: The sensitivity of CT colonography increased with lesion size (P<0.001), and was 91% (21/23) for lesions > or = 10 mm. All 10 carcinomas and 86% (19/22) of adenomas > or = 5 mm were detected. Unconfirmed or false-positive CT findings were generally small and/or reported with low diagnostic certainty. The specificity of CT colonography would be 45% (30/66; 95% CI 34% to 57%) if patients with findings of any size and any diagnostic certainty were selected for follow-up, and 92% (85/92; 95% CI 85% to 96%) if only ...

2006-11-15

393

Development program for magnetically assisted chemical separation: Evaluation of cesium removal from Hanford tank supernatant  

International Nuclear Information System (INIS)

Magnetic particles (MAG*SEP"S"M) coated with various absorbents were evaluated for the separation and recovery of low concentrations of cesium from nuclear waste solutions. The MAG*SEP"S"M particles were coated with (1) clinoptilolite, (2) transylvanian volcanic tuff, (3) resorcinol formaldehyde, and (4) crystalline silico-titanate, and then were contacted with a Hanford supernatant simulant. Particles coated with the crystalline silico-titanate were identified by Bradtec as having the highest capacity for cesium removal under the conditions tested (variation of pH, ionic strength, cesium concentration, and absorbent/solution ratio). The MAG*SEP"S"M particles coated with resorcinol formaldehyde had high distribution ratios values and could also be used to remove cesium from Hanford supernant simulant. Gamma irradiation studies were performed on the MAG*SEP"S"M particles with a gamma dose equivalent to 100 cycles of use. This irradiation decreased the loading capacity and distribution ...

1994-05-09

394

Detection of pulmonary aspiration in infants and children with respiratory disease: concise communication  

Energy Technology Data Exchange (ETDEWEB)

Twenty children with respiratory disease ingested 500 ..mu..Ci of Tc-99m sulfur colloid orally, and scintigrams of the thorax were obtained to determine whether pulmonaryaspiration of gastric contents could be detected. The children ranged in age from 1 mo to 14 y; 13 were 8 months of age or younger. Children were studied at 5 min and 4 h after ingestion of Tc-99m sulfur colloid using a high-sensitivity computer oscilloscope to record 100K-count images. Additional images were obtained after the children had slept overnight. Five children (25%) showed definite pulmonary accumulation of activity; four of these also had a barium swallow and three showed either pulmonary aspiration of barium or moderately severe gastroesophageal reflux. Oral ingestion of Tc-99m sulfur colloid provides a noninvasive means for diagnosing pulmonary aspiration under physiologic conditions in infants and children.

1980-04-01

395

Carbon felt-based bioelectrocatalytic flow-through detectors: Highly sensitive amperometric determination of H2O2 based on a direct electrochemistry of covalently modified horseradish peroxidase using cyanuric chloride as a linking agent  

British Library Electronic Table of Contents (United Kingdom)

Horseradish peroxidase (HRP) was chemically modified using cyanuric chloride (CC) as a linking agent onto a carbon felt (CF), which is a microelectrode ensemble of micro carbon fiber (>7mm, diameter) with a random three-dimensional structure. The resulting HRP-modified CF (HRP-ccCF) exhibited well-defined redox waves based on the HRP heme Fe^I^I^I/Fe^I^I redox couple at -0.23V vs. Ag/AgCl (at pH 7.0), while the HRP-adsorbed CF (HRP-CF) showed no apparent redox couple in the same potential range, indicating that the chemical modification of HRP via CC facilitated the direct electron transfer (DET) between HRP and CF. The apparent heterogeneous electron transfer rate constant ks was estimated to be 35s^-^1. Cyclic voltammetry and electrochemical impedance spectroscopy revealed that the inter...

2011-01-01

396

Boron-Lined Neutron Detector Measurements  

Energy Technology Data Exchange (ETDEWEB)

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. Reported here are the results of tests of a newly designed boron-lined proportional counter option. ...

2009-11-02

397

Advanced nanoscale separations and mass spectrometry for sensitive high-throughput proteomics  

Energy Technology Data Exchange (ETDEWEB)

We review recent development in separations and mass spectrometric instrumentation for sensitive and high-throughput proteomic analyses. These efforts have been primarily focused on the development of high-efficiency (separation peak capacity of ~103) nanoscale liquid chromatography (nanoLC; e.g., flow rates extending down to ~20 nL/min at optimal separation linear velocities through narrow packed capillaries) in combination with advanced mass spectrometry (MS), including high sensitivity and high resolution Fourier transform ion cyclotron resonance (FTICR) MS. This technology enables MS analysis of low nanogram-level proteomic samples (i.e., nanoscale proteomics) with individual protein identification sensitivity at the low zeptomole-level. The resultant protein measurement dynamic range can reach 106 for nanogram-sized proteomic samples, while more abundant proteins can be detected from complex sub-picogram size proteome samples. The average ...

2005-06-01

398

Accumulation levels and characteristics of some pesticides in human adipose tissue samples from Southeast China  

British Library Electronic Table of Contents (United Kingdom)

This paper presents a comprehensive study of pesticide levels and bio-accumulation characteristics in human adipose tissues among residents of Southeast China. A large number of adipose samples (n=633) were selected for 58 pesticides and were analyzed by high sensitive Gas Chromatography-Tandem Mass Spectrometry (GC-MS/MS). The results showed that POPs pesticides were frequently detected, including 2,4prime-DDD, 2,4prime-DDE, 2,4prime-DDT, 4,4prime-DDD, 4,4prime-DDE, 4,4prime-DDT, a-HCH, b-HCH, g-HCH, d-HCH, hexachlorobenzene (HCB), and mirex. Other detected pesticide species were dicofol, methamidophos and chlordimeform, which have rarely been reported. Comparing to different countries, the concentrations of total DDT and HCH in these three Chinese southeastern sites were in the middle ra...

2011-01-01

399

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

Science.gov (United States)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. Supported by National Natural Science Foundation of China (10475112), Western Light ...

2008-05-01

400

ESR study of X-ray irradiated rare earth (Ln) ion-doped glaserite and Ln ion-doped langbeinite  

Energy Technology Data Exchange (ETDEWEB)

X-ray irradiation-induced paramagnetic radicals in rare earth (Ln) ion-doped glaserite and Ln ion-doped langbeinite were studied by means of ESR technique, aiming at developing the highly sensitive sensor for an ESR dosimetry. The samples were prepared by two kinds of procedures as follows. In one process, the glaserite (K{sub 3}Na(SO{sub 4}){sub 2}) matrix or the langbeinite (K{sub 2}Mg{sub 2}(SO{sub 4}){sub 3}) matrix were synthesized by heating the mixture of K{sub 2}SO{sub 4} and Na{sub 2}SO{sub 4} or the mixture of K{sub 2}SO{sub 4} and MgSO{sub 4} at 1023 K for 1 hour in He flow. The matrices obtained were mixed well with a fixed amount of Ln{sub 2}(SO{sub 4}){sub 3} (Ln=La, Eu, Gd, Lu) powder and heated at 1023 K for 1 hour in He flow. In the other process, the homogeneous mixture of a fixed amount of K{sub 2}SO{sub 4}, Na{sub 2}SO{sub 4} and Ln{sub 2}(SO{sub 4}){sub 3} powders or a fixed amount of K{sub 2}SO{sub 4}, MgSO{sub 4} and ...

1992-06-01

401

solQTL: a tool for QTL analysis, visualization and linking to genomes at SGN database  

UK PubMed Central (United Kingdom)

BackgroundA common approach to understanding the genetic basis of complex traits is through identification of associated quantitative trait loci (QTL). Fine mapping QTLs requires...Full Text Available

402

Use of DNA ladders for reproducible protein fractionation by SDS-PAGE for quantitative proteomics  

UK PubMed Central (United Kingdom)

In proteomics, one-dimensional (1D) SDS-PAGE is widely used for protein fractionation prior to mass spectrometric analysis to enhance dynamic range of analysis and to improve identification...Full Text Available

2008-02-01

403

Tissue distribution of brain-thymus shared antigens recognized by anti-brain xenosera in the rat, dog and man.  

UK PubMed Central (United Kingdom)

A comparative and quantitative study of the tissue distribution of brain-thymus shared antigens was carried out using rabbit antisera to rat, dog and human brain homogenates, assayed on rat, dog and...Full Text Available

1979-03-01

404

The inhibition of tumor cell intravasation and subsequent metastasis through the regulation of in vivo tumor cell motility by the tetraspanin CD151  

UK PubMed Central (United Kingdom)

SummaryIn vivo tumor cell migration through integrin-dependent pathways is key to the metastatic behavior of malignant cells. Using quantitative in vivo...Full Text Available

2008-03-01

405

Subventricular Zone Cell Migration: Lessons from Quantitative Two-Photon Microscopy  

UK PubMed Central (United Kingdom)

Neuroblasts born in the adult subventricular zone (SVZ) migrate long distances in the rostral migratory stream (RMS) to the olfactory bulbs where they integrate into circuitry as functional interneurons....Full Text Available

406

Study on the transient piping vibration of power plant. Secondary piping system of Wolsung 1 unit.  

Science.gov (United States)

In order to maintain a safe operation and availability of generating facilities, qualitative and quantitative assessment of piping vibration was performed vibration sources and damages of piping support was identified on the second piping system of Wolsun...

1996-01-01

407

Study of building materials impregnation processes by quasi-real-time neutron radiography  

International Nuclear Information System (INIS)

Neutron radiography (NR) is a useful non-destructive method for determination of hydrogen content in various building and technical materials. Monitoring of transport processes of moisture and hydrogenous liquids in porous building materials is enabled by fast, quasi-real-time NR methods based on novel imaging plate neutron detectors (IP-NDs). Hydrogen content in the samples is determined by quantitative analysis of measured profiles of neutron attenuation in the samples. Detailed description of quantitative NR method is presented by the authors in another accompanying contribution at this conference. Deterioration of building materials is originated by different processes that all require presence of water therefore it is essential to limit or prevent the transport of water through the porous material. In this presentation, results of a study of clay brick impregnation by silicone based hydrophobic agents will be presented. ...

1999-11-03

408

Structure of lipid bilayers  

UK PubMed Central (United Kingdom)

The quantitative experimental uncertainty in the structure of fully hydrated, biologically relevant, fluid (Lα) phase lipid bilayers has been too large to...Full Text Available

2000-11-10

409

Solid-Phase Radioimmunoassay of Total and Influenza-Specific Immunoglobulin G  

UK PubMed Central (United Kingdom)

An antigen-antibody system of polystyrene tubes coated with immunoglobulin antibody was used for quantitating immunoglobulins. A similar radioimmunoassay method was adapted for a viral antigen-antibody...Full Text Available

1972-02-01

410

Quantitative bone scintigraphy in children and adolescents. Age dependence of skeleton uptake  

International Nuclear Information System (INIS)

French ... Orig. Title Scintigraphie osseuse quantifiee chez l'enfant et l'adolescent - repartition selon l'age des taux de fixation de diverses pieces osseuses normales.

411

Quantitative bone scintigraphy and 24-hour whole-body counting of [sup 99m]Tc-methylene diphosphonate in patients with prostatic carcinoma  

Energy Technology Data Exchange (ETDEWEB)

Thirty-four patients with prostatic carcinoma were studied with quantitative bone scintigraphy and whole-body counting (WBC) 1 and 24 h after injection of [sup 99m]Tc-MDP before as well as two weeks and two months after orchiectomy. Thirteen of the patients had normal bone scintigrams and WBR at the three different investigations; 21 had skeletal metastases. The latter showed throughout the study higher local gamma camera count rates as well as WBR values than the patiens with normal scintigrams. In these patients a ''flare phenomenon'', with an increase in count rate two weeks after orchiectomy followed by a decrease two months post-operatively, was seen with quantitative bone scintigraphy but not with WBC. However, WBC may be a valuable method indicating the total extent of skeletal metastases in the body, while quantitative bone scintigraphy is more accurate in the interpretation of ...

1992-10-01

412

Quantitative bone scintigraphy and 24-hour whole-body counting of "9"9"mTc-methylene diphosphonate in patients with prostatic carcinoma  

International Nuclear Information System (INIS)

Thirty-four patients with prostatic carcinoma were studied with quantitative bone scintigraphy and whole-body counting (WBC) 1 and 24 h after injection of "9"9"mTc-MDP before as well as two weeks and two months after orchiectomy. Thirteen of the patients had normal bone scintigrams and WBR at the three different investigations; 21 had skeletal metastases. The latter showed throughout the study higher local gamma camera count rates as well as WBR values than the patiens with normal scintigrams. In these patients a ''flare phenomenon'', with an increase in count rate two weeks after orchiectomy followed by a decrease two months post-operatively, was seen with quantitative bone scintigraphy but not with WBC. However, WBC may be a valuable method indicating the total extent of skeletal metastases in the body, while quantitative bone scintigraphy is more accurate in the interpretation of individual skeletal metastases. (orig.).

413

Quantitative and Qualitative Usage Data of an Internet-Based Asthma Monitoring Tool  

UK PubMed Central (United Kingdom)

Background In May 2000, AstraZeneca launched a Web service for asthma patients and health-care providers called LinkMedica, which includes an asthma diary for...Full Text Available

414

Quantitative analysis of the disopyramide concentration-effect relationship.  

UK PubMed Central (United Kingdom)

1. A combined pharmacokinetic-pharmacodynamic model has been used to analyse the relationship between QT prolongation and changes in plasma concentration which occurred after disopyramide was given...Full Text Available

1980-01-01

415

Quantitative Skeletal Histology in Untreated End-stage Renal Failure  

UK PubMed Central (United Kingdom)

Forty-six patients with end-stage renal failure were subjected to iliac crest biopsy before the initiation of a dialysis programme and regardless of the presence of skeletal symptoms....Full Text Available

1973-06-30

416

Quantitative PCR Assay for Mycobacterium pseudoshottsii and Mycobacterium shottsii and Application to Environmental Samples and Fishes from the Chesapeake Bay?  

UK PubMed Central (United Kingdom)

Striped bass (Morone saxatilis) in the Chesapeake Bay are currently experiencing a very high prevalence of mycobacteriosis associated with newly described Mycobacterium...Full Text Available

2010-09-01

417

Quantitative Analysis of Endocytosis and Turnover of Epidermal Growth Factor (EGF) and EGF Receptor  

UK PubMed Central (United Kingdom)

Binding of epidermal growth factor (EGF) to the EGF receptor (EGFR) initiates signal transduction, ultimately leading to altered gene expression. Ligand-activated EGFR is also rapidly internalized...Full Text Available

2010-03-01

418

Qualitative and Quantitative Effects of Treatment for Dental Fear and Avoidance  

UK PubMed Central (United Kingdom)

In a Swedish community-based program for the treatment of dental phobic patients, a clinical trial was performed among 99 severely phobic individuals with long-standing avoidance of dental treatment....Full Text Available

1986-01-01

419

QTL detection by multi-parent linkage mapping in oil palm (Elaeis guineensis Jacq.)  

UK PubMed Central (United Kingdom)

A quantitative trait locus (QTL) analysis designed for a multi-parent population was carried out and tested in oil palm (Elaeis guineensis Jacq.), which is a diploid cross-fertilising...Full Text Available

2010-05-01

420

Precise temporal control of the eye regulatory gene Pax6 via enhancer-binding site affinity  

UK PubMed Central (United Kingdom)

How transcription factors interpret the cis-regulatory logic encoded within enhancers to mediate quantitative changes in spatiotemporally restricted expression patterns during animal...Full Text Available

2010-05-15

421

Practical Applications of the Bioinformatics Toolbox for Narrowing Quantitative Trait Loci  

UK PubMed Central (United Kingdom)

Dissecting the genes involved in complex traits can be confounded by multiple factors, including extensive epistatic interactions among genes, the involvement of epigenetic regulators, and the variable...Full Text Available

2008-12-01

422

Pion-induced fission  

Energy Technology Data Exchange (ETDEWEB)

The A(..pi../sup +/,/sup 3/He)B reaction near threshold is studied in a model where the pion is absorbed by an /sup 4/He constituent of the target nucleus. The predictions of this model using harmonic oscillator cluster wave functions agree semi-quantitatively with the experimental data on the inverse reaction.

1982-03-10

423

Physical Morphology and Quantitative Characterization of Chemical Changes of Weathered PVC/Pine Composites.  

Science.gov (United States)

This study investigated weathering effects on polyvinyl chloride (PVC) based wood plastic composites (WPC), with a focus on the color and structure that is attributed to the material composition. It is directed towards quantifying the main chemical modifi...

2009-01-01

424

Pattern formation and traveling waves in myxobacteria: Theory and modeling  

UK PubMed Central (United Kingdom)

Recent experiments have provided new quantitative measurements of the rippling phenomenon in fields of developing myxobacteria cells. These measurements have enabled us to develop a mathematical model...Full Text Available

2001-12-18

425

Palliative Care Physicians' Religious / World View and Attitude Towards Euthanasia: A Quantitative Study Among Flemish Palliative Care Physicians  

UK PubMed Central (United Kingdom)

Aims:To Study the religious and ideological views and practice of Palliative Care physician towards Euthanasia.Materials and Methods:An...Full Text Available

2009-01-01

426

Observations on computerized quantitative bone scintigraphy in renal osteodystrophy  

Energy Technology Data Exchange (ETDEWEB)

Skeletal radiotracer (sup(99m)Tc-HEDP) uptake was quantitated with and without the aid of a computer in 30 chronic dialysis patients with histologic evidence of renal osteodystrophy. Before scintigraphy, elevated soft-tissue activity due to the absence of renal radiotracer excretion was reduced by hemodialysis. The results were compared with those of a normal group and with the results of the biochemical and the bone morphometric studies of these patients. In all patients the radiotracer uptake was elevated, often markedly. In several patients with minimal histologic bone disease, however, soft-tissue activity could not be normalized by hemodialysis although its influence on the quantitative data could be further reduced (but not excluded) by computer evaluation of skeletal radiotracer uptake. Since the latter technique clearly distinguished the majority of the patients from the normals, it appears that computerized ...

1984-09-01

427

Observations on computerized quantitative bone scintigraphy in renal osteodystrophy  

International Nuclear Information System (INIS)

Skeletal radiotracer (sup(99m)Tc-HEDP) uptake was quantitated with and without the aid of a computer in 30 chronic dialysis patients with histologic evidence of renal osteodystrophy. Before scintigraphy, elevated soft-tissue activity due to the absence of renal radiotracer excretion was reduced by hemodialysis. The results were compared with those of a normal group and with the results of the biochemical and the bone morphometric studies of these patients. In all patients the radiotracer uptake was elevated, often markedly. In several patients with minimal histologic bone disease, however, soft-tissue activity could not be normalized by hemodialysis although its influence on the quantitative data could be further reduced (but not excluded) by computer evaluation of skeletal radiotracer uptake. Since the latter technique clearly distinguished the majority of the patients from the normals, it appears that computerized ...

428

Neutron data requirements for calculating transactinide isotope build-up in reactors  

International Nuclear Information System (INIS)

Based on a generalized theory of perturbations and on non-linear programming an approach to the quantitative determination of necessary accuracies for nuclear data is described. It is used to calculate transactinide isotope build-up in reactors.

1979-08-01

429

Mechanistic insights from a quantitative analysis of pollen tube guidance  

UK PubMed Central (United Kingdom)

BackgroundPlant biologists have long speculated about the mechanisms that guide pollen tubes to ovules. Although there is now evidence that ovules emit a diffusible attractant, little...Full Text Available

430

Measuring the efficacy of anti-malarial drugs in vivo: quantitative PCR measurement of parasite clearance  

UK PubMed Central (United Kingdom)

BackgroundArtemisinin-based combination therapy, currently considered the therapy of choice for uncomplicated Plasmodium falciparum malaria in endemic countries,...Full Text Available

431

Localization of gold in synovial membrane of rheumatoid arthritis treated with sodium aurothiomalate. Studies by electron microscope and electron probe x-ray microanalysis.  

UK PubMed Central (United Kingdom)

The localization of gold in the synovial membrane of rheumatoid arthritis patients treated with sodium aurothiomalate was examined and quantitative analysis of epon-embedded sections was carried out...Full Text Available

1977-06-01

432

Immunoradiometric measurement of the factor VIII procoagulant antigen.  

UK PubMed Central (United Kingdom)

A fluid-phase immunoradiometric assay has been developed which identifies an antigen on the Factor VIII (antihemophilic factor) procoagulant protein. This sensitive and quantitative assay is not influenced...Full Text Available

1978-11-01

433

Image-based modeling of tumor shrinkage in head and neck radiation therapy1  

UK PubMed Central (United Kingdom)

Purpose: Understanding the kinetics of tumor growth∕shrinkage represents a critical step in quantitative assessment of therapeutics and realization of adaptive radiation therapy....Full Text Available

2010-05-01

434

High-Throughput Screen for Poly-3-Hydroxybutyrate in Escherichia coli and Synechocystis sp. Strain PCC6803  

UK PubMed Central (United Kingdom)

A novel, quantitative method for detecting poly-3-hydroxybutyrate (PHB) amounts in viable cells was developed to allow for high-throughput screening of mutant libraries. The staining technique was demonstrated...Full Text Available

2006-05-01

435

Gravitropism: Interaction of Sensitivity Modulation and Effector Redistribution 1  

UK PubMed Central (United Kingdom)

Our increasing capabilities for quantitative hormone analysis and automated high resolution growth studies have allowed a reassessment of the classical Cholodny-Went hypothesis of gravitropism. According...Full Text Available

1991-01-01

436

Gene expression patterns in four brain areas associate with quantitative measure of estrous behavior in dairy cows  

UK PubMed Central (United Kingdom)

BackgroundThe decline noticed in several fertility traits of dairy cattle over the past few decades is of major concern. Understanding of the genomic factors underlying fertility,...Full Text Available

437

Functional pools of oxidative and glycolytic fibers in human muscle observed by 31P magnetic resonance spectroscopy during exercise.  

UK PubMed Central (United Kingdom)

Quantitative probing of heterogeneous regions in muscle is feasible with phosphorus-31 magnetic resonance spectroscopy because of the differentiation of metabolic patterns of glycolytic and oxidative...Full Text Available

1987-12-01

438

Free and Conjugated Indole-3-Acetic Acid in Developing Bean Seeds 1  

UK PubMed Central (United Kingdom)

The changes in conjugated indole-3-acetic acid (IAA) levels compared to the levels of free IAA have been analyzed during the development of bean (Phaseolus vulgaris L.) seed using quantitative...Full Text Available

1989-10-01

439

Evolution of Nitrogen Oxide(s) during In Vivo Nitrate Reductase Assay of Soybean Leaves  

UK PubMed Central (United Kingdom)

Studies were conducted to quantitate the evolution of nitrogen oxides (NO(x)) from soybean [Glycine max (L.) Merr.] leaves during in vivo nitrate reductase...Full Text Available

1981-12-01

440

Effect of pH and Temperature on Denitrification Gene Expression and Activity in Pseudomonas mandelii?  

UK PubMed Central (United Kingdom)

Pseudomonas mandelii liquid cultures were studied to determine the effect of pH and temperature on denitrification gene expression, which was quantified by quantitative reverse transcription-PCR....Full Text Available

2009-06-01

441

Determination of Salirasib (S-trans, trans-farnesylthiosalicylic acid) in human plasma using liquid chromatography-tandem mass spectrometry  

UK PubMed Central (United Kingdom)

A liquid chromatography/tandem mass spectrometric (LC/MS/MS) assay was developed for the quantitative determination of salirasib (S-trans, trans-farnesylthiosalicylic acid,...Full Text Available

2008-06-15

442

Delineation of the Middle Longitudinal Fascicle in Humans: A Quantitative, In Vivo, DT-MRI Study  

UK PubMed Central (United Kingdom)

Experimental and imaging studies in monkeys have outlined various long association fiber bundles within the temporoparietal region. In the present study the trajectory of the middle longitudinal fascicle...Full Text Available

2009-04-01

443

Cytoplasmic pH Regulation in Acer pseudoplatanus Cells  

UK PubMed Central (United Kingdom)

Qualitative and quantitative aspects of the mechanisms involved in the regulation of cytoplasmic pH during an acid-load have been studied in Acer pseudoplatanus cells. Two main processes,...Full Text Available

1986-11-01

444

Ct3d: tracking microglia motility in 3D using a novel cosegmentation approach  

UK PubMed Central (United Kingdom)

Motivation: Cell tracking is an important method to quantitatively analyze time-lapse microscopy data. While numerous methods and tools exist for tracking cells in 2D time-lapse images,...Full Text Available

2011-02-15

445

Comparison of Optical and SEM BSE Imaging Techniques for Quantifying Alpha-Beta Titanium Alloy Microstructures (Preprint).  

Science.gov (United States)

Quantitative metallography is often used to confirm the proper processing of aerospace metallic materials. A microstructural feature of great importance for titanium alloys processed in the alpha-beta phase field is the volume fraction of primary alpha. S...

2006-01-01

446

Bimodal MR-PET agent for quantitative pH imaging  

UK PubMed Central (United Kingdom)

Activatable or “smart” magnetic resonance contrast agents have relaxivities that depend on environmental factors such as pH or enzymatic activity, but the MR signal depends on...Full Text Available

2010-03-22

447

Bedload measurements, East Fork River, Wyoming  

UK PubMed Central (United Kingdom)

A bedload trap in the riverbed provided direct quantitative measurement of debris-transport rate in the East Fork River, Wyoming, a basin of 466 km2 drainage area. Traction load moves only...Full Text Available

1976-04-01

448

Bacterial Oxidation of Sulfide Minerals in Column Leaching Experiments at Suboptimal Temperatures  

UK PubMed Central (United Kingdom)

The purpose of the work was to quantitatively characterize temperature effects on the bacterial leaching of sulfide ore material containing several sulfide minerals. The leaching was tested at eight...Full Text Available

1992-02-01

449

Augmenting Clinical Evaluation of Hemiparetic Arm Movement With a Laboratory-Based Quantitative Measurement of Kinematics as a Function of Limb Loading  

UK PubMed Central (United Kingdom)

BackgroundKinematic and kinetic measurements used in laboratory settings can quantify upper extremity movement impairment following stroke, but their relationship...Full Text Available

2008-01-01

450

Arabidopsis thaliana auxotrophs reveal a tryptophan-independent biosynthetic pathway for indole-3-acetic acid.  

UK PubMed Central (United Kingdom)

We used tryptophan auxotrophs of the dicot Arabidopsis thaliana (wall cress) to determine whether tryptophan has the capacity to serve as a precursor to the auxin, indole-3-acetic acid (IAA). Quantitative...Full Text Available

1993-11-01

451

Application of alpha and gamma spectroscopy to the quantitative analysis of transuranium nuclides in nuclear fuel  

Energy Technology Data Exchange (ETDEWEB)

In nuclear fuel with a burn-up of 33 kg/t U and 52 kg/t U 15 transuranium nuclides /sup 237/Np to /sup 246/Cm have been determined by alpha and gamma spectroscopy after radiochemical separation.

1984-11-01

452

Analysis of trigeminal nerve disorders after oral and maxillofacial intervention  

UK PubMed Central (United Kingdom)

BackgroundQuantitative sensory testing (QST) is applied to evaluate somatosensory nerve fiber function in the spinal system. This study uses QST in patients with sensory dysfunctions...Full Text Available

453

Analysis of Quantitative Interactions between Two Species of Arbuscular Mycorrhizal Fungi, Glomus mosseae and G. intraradices, by Real-Time PCR  

UK PubMed Central (United Kingdom)

Arbuscular mycorrhizal fungi (AMF) are obligate biotrophs, known to play an important role in ecological processes. Conventional light microscopy is the most common method used to detect their presence...Full Text Available

2006-06-01

454

An ounce of prevention or a pound of cure: bioeconomic risk analysis of invasive species.  

UK PubMed Central (United Kingdom)

Numbers of non-indigenous species--species introduced from elsewhere - are increasing rapidly worldwide, causing both environmental and economic damage. Rigorous quantitative risk-analysis frameworks,...Full Text Available

2002-12-07

455

Advances in metallography. Fortschritte in der Metallographie  

Energy Technology Data Exchange (ETDEWEB)

The 52 papers discuss the following subjects: 1. Preparation and structural development; 2. Structural constitution; 3. Structural formation and phase transition; 4. Structure and mechanical properties; 5. Structural formation of metallic and nonmetallic materials; 6. Quantitative metallography, and 7. Quality assurance.

1983-01-01

456

A double antibody solid phase assay for DNA autoantibodies for clinical use.  

UK PubMed Central (United Kingdom)

DNA antoantibodies in serum will bind to antigen-coated polystyrene tubes and can be detected by radiolabelled anti-immunoglobulin. The method is quantitative, gives information on the antibody class...Full Text Available

1976-08-01

457

A Rapid Murine Coma and Behavior Scale for Quantitative Assessment of Murine Cerebral Malaria  

UK PubMed Central (United Kingdom)

BackgroundCerebral malaria (CM) is a neurological syndrome that includes coma and seizures following malaria parasite infection. The pathophysiology is not fully understood and cannot...Full Text Available

458

Theoretical approach on microscopic bases of stochastic functional self-organization: quantitative measures of the organizational degree of the environment  

International Nuclear Information System (INIS)

There has been increased theoretical and experimental research interest in autonomous mobile robots exhibiting cooperative behaviour. This paper provides consistent quantitative measures of organizational degree of a two-dimensional environment. We proved, by the way of numerical simulations, that the theoretically derived values of the feature are reliable measures of aggregation degree. The slope of the feature's dependence on memory radius leads to an optimization criterion for stochastic functional self-organization. We also described the intellectual heritages that have guided our research, as well as possible future developments. (author)

2001-11-30

459

Quantitative density measurements from a real-time neutron radiography system  

Energy Technology Data Exchange (ETDEWEB)

An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.

1986-01-01

460

Quantitative density measurements from a real-time neutron radiography system  

International Nuclear Information System (INIS)

An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.

1986-11-16

461

Quantitative bone scintigraphy in the evaluation of angular deformity of the lower extremity  

International Nuclear Information System (INIS)

A technique for quantitative analysis of growth plates in varus or valgus deformity about the knee has been developed. Computer-generated regions of interest are placed on magnification scintigraphs to divide distal femoral and proximal tibial physes into four equal segments. The ratio of counts in the medial half to counts in the lateral half was studied in 31 children (22 normal, 9 with angular deformity). Normal ratios were 0.74 to 0.98 for femora and 0.98 to 1.20 for tibias. In eight of nine patients with deformity, the ratio was abnormal; in two patients the ratio returned to normal when the deformity ceased to progress.

462

Quantitative analysis of iodine in thyroidin. II. Method of combustion in flask with oxygen  

Energy Technology Data Exchange (ETDEWEB)

The authors experimentally study the separate stages of the determination of iodine in thyroidin by the combustion method in a flask with oxygen. The monotypic, conventional procedures and the procedure of Kolii and Pakhomov were studied. With addition of potassium iodide, a sixfold amount (compared with the initial) of iodine is liberated. Further, the liberated iodine is titrated by sodium thiosulfate. The authors find the degree of influence of a high nitrogen content on the determination of iodine in organic compounds. The procedure developed for the quantitative determination of the iodine in thyroidin by the combustion method is simple, fairly rapid, and can be used for the reliable control of the quality of thyroidin preparations and its starting raw material.

1986-11-01

463

Prediction of the compressive strength of vertebral bodies of the lumbar spine by quantitative computed tomography.  

Science.gov (United States)

The ultimate compressive strength of 36 thoracolumbar vertebrae was determined experimentally. In addition, the trabecular bone mineral content was measured by single energy quantitative computed tomography. The areas of fractured endplates were also determined by computed tomography. The results show that a linear relationship exists between the compressive strength and the product of bone density and endplate area. These data allow an in vivo prediction of vertebral body strength using a noninvasive method with a standard error of estimate amounting to less than 0.95 kN. PMID:3212488

1988-01-01

464

Mass fragmentographic determination of polymethylnaphthalene and polymethylphenanthrene in a crude oil and in marine organisms  

Energy Technology Data Exchange (ETDEWEB)

The investigation of the petroleum contamination in marine organisms requires the trace level quantitative determination of indicative substances to be identified by a fingerprint of petroleum. Polymethylnaphthalene (PMN) and polymethylphenanthrene (PMP) were chosen because of their simple separation from a crude oil by means of an activated charcoal chromatography, their relatively high existence in aromatic compounds, and their persistence relative to other petroleum components in the tissue of oil contaminated marine organisms. The purpose of this paper is to present an activated charcoal chromatographic separation procedure of PMN and PMP in a crude oil and a trace level quantitative analytical method of them in marine organisms by mass fragmentography (MF).

1980-09-01

465

Fuzzy performance measurement of a supply chain in manufacturing companies  

British Library Electronic Table of Contents (United Kingdom)

This paper is aimed to present a fuzzy decision making approach to deal with the performance measurement in supply chain systems. In the manufacturing environment, performance measurement is based on different quantitative and qualitative factors. Some of these factors may have a larger effect on the performance measure than others. Units of measure of the quantitative factors are different such as time, money, percentage, ratio, and counts. Thus, this paper presents a performance measurement approach based on fuzzy set theory and the pair-wise comparison of Analytical Hierarchy Process (AHP), which ensures the consistency of the designer's assignments of importance of one factor over another to find the weight of each of the manufacturing activity in the departmental organization. In the ...

2011-01-01

466

Effects of carbocalcitonin treatment on PAGET's disease assessed by quantitative bone scintigraphy  

International Nuclear Information System (INIS)

Sixteen patients with PAGET's disease of bone underwent quantitative bone scintigraphy with "9"9"mTc-MDP before and after a long-term treatment with carbocalcitonin, a synthetic analogue of eel calcitonin. The radionuclide study consisted in the blood pool and bone uptake measurement and in the bone avidity calculation (bone uptake - blood pool ratio). In our patients, a significant decrease in bone uptake and bone avidity was found, whereas the blood pool remained statistically unchanged. This behaviour could be accounted for the shift of the compact bone to a lamellar pattern. (orig.).

467

Effects of carbocalcitonin treatment on PAGET's disease assessed by quantitative bone scintigraphy  

Energy Technology Data Exchange (ETDEWEB)

Sixteen patients with PAGET's disease of bone underwent quantitative bone scintigraphy with /sup 99m/Tc-MDP before and after a long-term treatment with carbocalcitonin, a synthetic analogue of eel calcitonin. The radionuclide study consisted in the blood pool and bone uptake measurement and in the bone avidity calculation (bone uptake - blood pool ratio). In our patients, a significant decrease in bone uptake and bone avidity was found, whereas the blood pool remained statistically unchanged. This behaviour could be accounted for the shift of the compact bone to a lamellar pattern.

1988-06-01

468

Development of safety function assessment trees for pressurized heavy water reactor LP/SD operations  

Energy Technology Data Exchange (ETDEWEB)

The objective of Configuration Risk Management Program(CRMP) is to maintain the safety level by assuring the defense-in-depth of nuclear power plant while the configurations are changed during plant operations, especially for the LP/SD. Such a safety purpose can be achieved by establishing the risk monitoring programs with both quantitative and qualitative features. Generally, the quantitative risk evaluation models, i.e., PRA models are used for the risk evaluation during full power operation, and the qualitative risk evaluation models such as safety function assessment trees are used. Through this study, safety function assessment trees were developed.

2003-10-01

469

X-Ray Fluorescence in Research on the Cultural Heritage  

Energy Technology Data Exchange (ETDEWEB)

Radionuclide X-ray fluorescence analysis is a method, which has many advantages for analysing various historic artefacts, as it is relatively cheap, sensitive and non-destructive, and it allows measurements in-situ. However, this analysis has also certain limitations especially concerning sensitivity to chemical elements only, irrespective of the compounds or chemical forms in which these elements have been bonded. In addition, light elements emitting very soft X-rays cannot be measured, and in order to detect a wide range of elements, it is necessary to carry out repeated measurements with different radiation sources. Despite these limitations, valuable information can be obtained about the composition of historic materials and data about the origin and age of these artefacts can be derived. Analyses of wall paintings, ancient metal sculptures or other objects of art provide the basis for historic considerations documented in our results for some objects belonging ...

2001-09-15

470

X-Ray Fluorescence in Research on the Cultural Heritage  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis is a method, which has many advantages for analysing various historic artefacts, as it is relatively cheap, sensitive and non-destructive, and it allows measurements in-situ. However, this analysis has also certain limitations especially concerning sensitivity to chemical elements only, irrespective of the compounds or chemical forms in which these elements have been bonded. In addition, light elements emitting very soft X-rays cannot be measured, and in order to detect a wide range of elements, it is necessary to carry out repeated measurements with different radiation sources. Despite these limitations, valuable information can be obtained about the composition of historic materials and data about the origin and age of these artefacts can be derived. Analyses of wall paintings, ancient metal sculptures or other objects of art provide the basis for historic considerations documented in our results for some objects belonging ...

2001-09-01

471

Theoretical modelling of X-ray fluorescence signals for different lunar compositions and dependence on solar activity  

British Library Electronic Table of Contents (United Kingdom)

We present a forward modelling technique for calculating the surface X-ray spectra for a variety of lunar terrains. Our calculations considered variations in solar fluxes from solar quiescent condition to large flare activity (M1 flare), and expected elemental concentrations in the target, as well as yield, instrumental, and viewing geometry parameters for X-ray induced fluorescence from the lunar surface. Additionally, we present estimates of anticipated XRF signals from prominent Ka lines observable by a collimated 14cm2 X-ray detector from a 100km lunar orbit with 20km spatial resolution. Our results show that Mg, Al and Si characteristic Ka lines can be observed for all solar conditions. The Ca Ka lines line can be differentiated from a fixed background during more energetic solar cond...

2010-01-01

472

The influence of treatment with thiotepa, thyroxine and D3 vitamin and the effect of fast neutron radiolysis on walker tumor chromatin  

International Nuclear Information System (INIS)

Anticancer drug thyotepa (10 mg/ kg) hormonal compound thyroxine (40 mg / kg) and D3 vitamin (30,000 IU / kg) have been administrated simply or associated to Wistar rats bearing Walker carcinosarcoma. The chromatin (the complex of DNA and proteins from nuclei) has been extracted from Walker tumor and submitted to fast neutron beams produced by deuterons (13 MeV) on thick Be target at an IPNE U-120 Cyclotron, in doses of 5-100 Gy. Thermal transition of chromatin fluorescence intensity of chromatin-ethidium bromide complexes and intrinsic fluorescence of chromatin have been analysed. Association of thiotepa with thyroxine and D3 vitamin produced a diminution of chromatin lesions induced by the cytostatic. Thus in the effects of fast neutrons radiolysis in chromatin significant differences occurred. These results could help to improve the methodology of associated chemotherapy-radiotherapy in clinical applications. (author).

1995-12-02

473

Radioanalytical determination of chromium in welding fumes  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis and fast neutron activation analysis were used for the determination of chromium. The excitation source for X-ray fluorescence analysis was a ring-shaped "2"4"1Am source with an activity of 18.5x10"9 Bq. SYNPOR filters of 35 mm in diameter were used for the measurement. The 5.414 keV Cr peak was measured with a Si(Li) detector. The sensitivity was 0.05 mg for a period of measurement of 1000 s. A neutron generator with an emission of 10"9 s"-"1 was used as the source of fast neutrons. "5"2V and "5"3V, the products of nuclear reaction with Cr, were measured gamma spectrometrically with a Ge(Li) detector. The sensitivity for Cr is 0.015 mg, in the presence of Mn which causes interference the sensitivity is a mere 0.075 mg. The mentioned methods were used to determine total Cr and Cr(VI) in welding aerosols. It was found that the most toxic form, i.e., Cr(VI), is released during manual arc welding of high ...

1985-01-01

474

Photophysical characteristics of 4,4'-bis(N-carbazolyl)tolan derivatives and their application in organic light emitting diodes  

International Nuclear Information System (INIS)

4,4'-bis(N-carbazolyl)tolan (BCT) and 4,4'-bis[N-(3,6-di-t-butyl)carbazolyl]tolan (BCT-t-Bu) were synthesized as ?-expanded analogs of 4,4'-bis(N-carbazolyl)biphenyl. Their photophysical characteristics both in solution and films were thoroughly investigated. Interestingly, the phosphorescence spectrum of BCT was significantly medium-dependent, and the emission maximum was red-shifted by 131 nm from 489 nm in solution at 77 K to 620 nm in a deposited film at 5 K, suggesting the presence of strong intermolecular interactions in the film. BCT and BCT-t-Bu were found to be useful as host materials for fluorescence-based organic light emitting diodes (OLEDs). However, their low triplet energy levels in films negated their potential to act as hosts in phosphorescence-based OLEDs. - Research highlights: ? We synthesized N-carbazolyl-tolan derivatives (BCT) as ?-expanded analogues of CBP. ? We found that BCT derivatives are useful as host materials for ...

2011-07-01

475

Photochemical reactivity of the homologous proteins. cap alpha. -lactalbumin and lysozyme  

Energy Technology Data Exchange (ETDEWEB)

The fluorescent behaviour and the photodynamic effect was studied in native and structurally modified lysozyme and ..cap alpha..-lactalbumin. The Tyr residues in lysozyme and ..cap alpha..-lactalbumin show different sensitivities to the photodynamic effect. The effect is zero in the case of Tyr from native lysozyme. In contrast, the Tyr residues in ..cap alpha..-lactalbumin are susceptible to photooxidation, which indicates a greater degree of exposure to the solvent. The three His residues of ..cap alpha..-lactalbumin have different degrees of exposure and show two different kinetics of photooxidation whereas the His residue of lysozyme is photooxidized with a single kinetic. Two photooxidation kinetics were obtained for the Trp residues of both native proteins, an indication that in both cases there are Trp residues that are differently exposed to the solvent. The wavelengths of maximum fluorescent emission of the Trp residues were different ...

1985-04-01

476

Mercury-free fluorescent lighting  

Energy Technology Data Exchange (ETDEWEB)

A brief comparative review of possible mercury free fluorescent lighting technologies is presented, including rare-gas positive column discharges, molecular discharges, and dielectric barrier discharges. Detailed experimental results on xenon positive column discharges will then be considered. In order to judge whether xenon-based discharges are a viable UV source it is necessary to measure the radiant emittance (power per unit area) for the vacuum ultraviolet (VUV) resonance xenon emission at 147 nm. Two techniques to determine the VUV radiant emittance have been developed and applied to xenon discharges. One method combines the measured resonance level density using absorption spectroscopy and a calculation of the trapped decay rate for the resonance radiation to arrive at the radiant emittance at 147 nm. A second method utilizes a direct measurement of the radiance (power per unit area per unit solid angle) at 147 nm using a calibrated VUV photodiode, and a ...

1996-05-01

477

Measuring head for radionuclide X-ray fluorescence analyzer  

International Nuclear Information System (INIS)

The design of a gaging head for a portable radionuclide X-ray fluorescence analyzer is described. The gaging head is designed as a construction unit system which enables the application of lateral reflexion geometry as well as of coaxial geometry. It is designed so that adjustment from one geometry to the other is labour and time saving. The selection of characteristic radiation is performed by a couple of Ross' differential filters. These filters are prepared by a novel technique developed by our laboratory. The filter exchange is effected by the longitudinal move of the couple of filters encapsulated in a holder. The shift of the filters is controlled by means of a triggering mechanism situated in the body of the gaging head handle. This design makes is possible to handle the gaging head during measurements with one hand. A simple interchange of the absorption filter for the transmissive filter allows the operator to avoid any unwanted shift of the head during ...

1976-05-21

478

Measurement of L X-ray fluorescence cross-sections for elements with 45 Z50 using synchrotron radiation at 8keV  

British Library Electronic Table of Contents (United Kingdom)

The L shell fluorescence cross-sections of the elements in range 45Z50 have been determined at 8keV using Synchrotron radiation. The individual L X-ray photons, Ll, La, LbI, LbII, LgI and LgII produced in the target were measured with high resolution Si(Li) detector. The experimental set-up provided a low background by using linearly polarized monoenergetic photon beam, improving the signal-to-noise ratio. The experimental cross-sections obtained in this work were compared with available experimental data from Scofield [1,2] Krause [3,4] and Scofield and Puri et al. [5,6]. These experimental values closely agree with the theoretical values calculated using Scofield and Krause data, except for the case of Lg, where values measured of this work are slighter higher.

2011-01-01

479

Luminescent determination of zirconium and hafnium with myricetin  

International Nuclear Information System (INIS)

Reaction of formation of 3, 5, 7, 3', 4', 5' - hexaoxiflavone - myricetin complexes with zirconium and hafnium ions has been the basis for development of luminescent method of determining these elements. Optimum conditions for complexing have been determined. For Hf they are : 8-9 HCl concentration, maximum fluorescence wave length (lambda fl.)of 520 nm, wave length of exciting light (lambda el) of 436 nm, for Zr lambda fl = 536nm, lambda el = 436 nm. Stable fluorescence establishes after 25 min. for Zr and after 15 min for Hf in the presence of 40% ethanol. Usage of various camouflage agents has permitted to attain high selectivity of the method. Possibility for determination of Zr with myricetin in the presence of a 10-time excess of Hf, Cr, Cu, 50-time excess of Mo and Ti is shown. Sensitivity of Zr determination is 2.0x10 #mu#g"-"2/ml, for Hf it is 9.0x10 #mu#g"-"3 and mineral waters.

480

Human cDNA mapping using fluorescence in situ hybridization. Progress report, April 1, 1992--December 31, 1992  

Energy Technology Data Exchange (ETDEWEB)

Genetic mapping is approached using the techniques of high resolution fluorescence in situ hybridization (FISH). This technology and the results of its application are designed to rapidly generate whole genome as tool box of expressed sequence to speed the identification of human disease genes. The results of this study are intended to dovetail with and to link the results of existing technologies for creating backbone YAC and genetic maps. In the first eight months, this approach generated 60--80% of the expressed sequence map, the remainder expected to be derived through more long-term, labor-intensive, regional chromosomal gene searches or sequencing. The laboratory has made significant progress in the set-up phase, in mapping fetal and adult brain and other cDNAs, in testing a model system for directly linking genetic and physical maps using FISH with small fragments, in setting up a database, and in establishing the validity and throughput of the system.

1993-03-04

481

High-efficiency RF suppression circuit for fluorescent lamp inverters using charge pump and partial smoothinf capacitors; Chagi ponpu shiki korikiritsu bubun heikatsu hoshiki wo mochiita keikoto inbatayo kochoha teigen kairo  

Energy Technology Data Exchange (ETDEWEB)

A highly efficiency partial smoothing method is proposed to be used for inverters for 40W class household fluorescent inverters. In this system, the input current from the commercial AC power source is accumulated in a capacitor with comparatively small capacity as the electric charge, and then the lamp circuit is driven by the inverter utilizing the charging voltage of the capacitor and the charging voltage of the separately prepared partial smoothing capacitor. By this method, the RF harmonic components in the supply current can be decreased to improve the power factor with no complicated feedback controlling device. In addition, comparatively small capacity coils and capacitors can be used. The structure of the circuit and the operation of this proposed method are described, and the operational characteristic of the prototype circuit and the result of analysis are shown. Furthermore, problems and improving method of the actual circuit are investigated by an ...

1997-06-20

482

Fabrication of single nanofluidic channels in poly(methylmethacrylate) films via focused-ion beam milling for use as molecular gates  

International Nuclear Information System (INIS)

Focused-ion beam (FIB) milling provides rapid fabrication of individual cylindrical submicrometer channels with reproducible dimensions (#+-#5% diameters) through 8-#mu#m thick poly(methylmethacrylate) (PMMA) films. PMMA films are spincast on sacrificial Si carriers and sputter-coated with Au before the 30-kV gallium FIB milling process. By adding a trace amount of poly(ethyleneoxide) and poly(dimethylsiloxane) to the PMMA solution before casting, the films can be released for subsequent mounting in microfluidic devices to create hybrid microfluidic-nanofluidic multilevel architectures. In situ FIB sectioning demonstrates the smooth cylindrical surface within the pore. Placing a milled film in contact with an aqueous fluorescein solution fills the channel by capillary action, as verified by confocal fluorescence microscopy. Confocal fluorescence of dyed films reveals that the pores span the thickness of the PMMA film. Small arrays of channels ...

2004-08-16

483

Development of lidar techniques for environmental studies  

Energy Technology Data Exchange (ETDEWEB)

The lidar group in Lund has performed many DIAL measurements with a mobile lidar system that was first described in 1987. The lidar system is based on a Nd:YAG-pumped dye laser. During the last few years the lidar group has focused on fluorescence imaging and mercury measurements in the troposphere. In 1994 we performed two campaigns: one fluorescence imaging measurement campaign outside Avignon, France and one unique lidar campaign at a mercury mine in Almaden, Spain. Both campaigns are described in this thesis. This thesis also describes how the mobile lidar system was updated with the graphical programming language LabVIEW to obtain a user friendly lidar system. The software controls the lidar system and analyses measured data. The measurement results are shown as maps of species concentration. All electronics and the major parts of the program are described. A new graphical technique to estimate wind speed from plumes is also discussed. ...

1996-09-01

484

Determination of small amounts of elements by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The determination of small amounts of elements by radionuclide X-ray fluorescence analysis is described. Samples containing 5x10"-"4 to 5x10"-"6 g of elements were fixed on a suitable carrier. For a coaxial configuration a low-energy source of the #gamma#/X type was used, namely an annular "2"4"1Am/Ag source with an activity of 7.4x10"8 s"-"1 (20 mCi), and for a configuration with side reflection source of the #beta#/X type was used, namely "1"4"7Pm/Sm with the activity of Pm(OH)_3 approximately 3.7x1O"1"0 s"-"1 (1 Ci). Cs, Ba, La, Pr, Nd, and Ag were determined by means of the Ksub(#alpha#) line and Hg, W, Er, and Pr by means of the Lsub(#alpha#) line. For all elements studied a detection limit of the order of 10"-"7 g was achieved. (author).

1975-01-01

485

Clinical and tomographic aspects of macular microholes; Aspectos clinicos e tomograficos dos microburacos maculares  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To describe the clinical aspects and evaluate optical coherence tomography of macular microholes. Methods: Seven patients were assessed (8 eyes) with microholes of the macula. All patients underwent complete eye examination, fundus photography, fluorescent angiography and OCT-3 imaging. Results: Ages ranged from 26 to 69 years. Six patients were female (85.7%) and five of them had microhole in the right eye. The presenting symptom was decrease in visual acuity (71.3%) and central scotoma in (14.3%). Five eyes (71.4%) had no defects shown by fluorescent angiography. A defect in the outer retina was demonstrated in all eyes on optical coherence tomography. The lesions were nonprogressive. Conclusion: Macular microholes are small lamellar defects in the outer retina. The condition is nonprogressive, generally unilateral and compatible with good visual acuity. Fundus biomicroscopy associated with an optical coherence tomography are the ...

2009-07-01

486

Behaviour of atomic oxygen in a pulsed dielectric barrier discharge measured by laser-induced fluorescence  

International Nuclear Information System (INIS)

Atomic oxygen is measured in a pulsed dielectric barrier discharge (DBD) using two-photon absorption laser-induced fluorescence (TALIF). The ground-level atomic oxygen is excited to the 3p "3P state by two-photon absorption at 226 nm. Negative (-40 kV) or positive (+30 kV) pulsed DBD occurs in an O_2-N_2 mixture at atmospheric pressure. The pulse width of the DBD current is approximately 50 ns. The TALIF experiment shows that the decay rate of atomic oxygen increases linearly with O_2 concentration. This result proves that atomic oxygen decays mainly by the third-body reaction, O + O_2 + M #-># O_3 + M. The rate coefficient of the third-body reaction is estimated to be 2.2 x 10"-"3"4 cm"6 s"-"1 in the negative DBD and 0.89 x 10"-"3"4 cm"6 s"-"1 in the positive DBD. It is shown that the decay rate of atomic oxygen increases linearly with humidity. This can explain the well-known fact that ozone production in DBD is suppressed by increasing humidity.

2005-08-21

487

Spectroscopic studies of the Sm/sub 3/Ga/sub 5/O/sub 12/ monocrystals  

Energy Technology Data Exchange (ETDEWEB)

The fluorescence, absorption, infrared and Raman spectra of Sm/sub 3/Ga/sub 5/O/sub 12/ have been investigated. The energy-level schemes in the energy range 3000-16000 cm/sup -1/ have been determined. The number and symmetries of the Sm/sub 3/Ga/sub 5/O/sub 12/ crystal normal mode have been obtained by the molecular site group analysis and their comparison with the experiment has been made.

1984-11-01

488

Quantum electrodynamic and semiclassical interference effects in spontaneous radiation  

International Nuclear Information System (INIS)

The theory of spontaneous decay is studied using both quantum electrodynamics (QED) and semiclassical theories of radiation. There are qualitative differences between the theories in the prediction of interference phenomena. In QED, systems which were excited with pulsed laser light do not exhibit quantum interference effects associated with lower state splittings. On the other hand, semiclassical treatments of spontaneous decay do indicate the existence of interference effects not present in QED. In addition to this, differences are found between the predictions of fluorescence intensity in the presence of lower-state level crossings under continuous excitation. (U.S.).

1975-01-01

489

Preparation and Properties of New Ester-Linked Cleavable Gemini Surfactants  

British Library Electronic Table of Contents (United Kingdom)

We have prepared a series of novel gemini surfactants having ester bonds in their structures. These surfactants possess two identical hydrophilic polyethylene glycol moieties, two hydrophobic alkyl group moieties, and an anionic spacer. The structures of these compounds were confirmed through infrared and nuclear magnetic resonance spectroscopic and elemental analyses. The novel gemini surfactants exhibit excellent surface activity in terms of their surface tension, low-foaming, wetting power, and fluorescence properties. The presence of the ester linkages made these structures cleavable surfactants.

2011-01-01

490

Nondestructive testing of metal coating thickness and control of chemical composition using radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The principle is described of a method using low-activity emitters as the primary radiation source for analysis. The selection of the radiation source and the detection methods including the assessment of the applicability of various radiation detectors are discussed. The benefits and the constraints of the method are considered. Practical examples are presented showing the application possibilities of the method for testing the thickness of bearing layers, piston ring coats, lead layers, etc. The possibility is shown of applying the rapid test for the composition of tungsten and chromium alloyed metal materials in testing complex systems. (J.K.).

1974-12-03

491

New coumarin-based sensor molecule for magnesium and calcium ions  

British Library Electronic Table of Contents (United Kingdom)

A new coumarin-based sensor molecule (L1) has been synthesized and this was found to bind calcium and magnesium ions more effectively as compared to other alkali/alkaline earth/lanthanide and certain transition metal ions. A significant enhancement in fluorescence intensity was observed on binding to Ca2+ and Mg2+ ions; while a minor quenching was observed for weakly bound Hg2+, Ni2+, Fe3+, and Co2+ ions. PET process, coupled with the ICT process, is proposed to explain the observed spectral response.

2009-01-01

492

Flow cytogenetics methodology and applications  

Energy Technology Data Exchange (ETDEWEB)

Flow cytogenetics is a rapidly developing technology which complements rather than supplants the traditional methods of cytogenetic analysis. As an adjunctive approach to chromosome classification, flow systems measurements of isolated chromosomes give new information relative to the enrichment of A-T or G-C base sequences on specific chromosomes. As a result, chromosomal fluorescence polymorphisms both within and among individuals that are not always associated with banding polymorphisms can be detected. Finally, flow sorting provides bulk quantities of highly purified chromosomes for use in biochemical studies. Methodology is detailed. (PSB)

1982-10-17

493

Estimation of X-rays dose in the crystals of final thickness  

International Nuclear Information System (INIS)

A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.

494

Elemental concentration analysis in some plant samples by EDXRF at Trabzon  

International Nuclear Information System (INIS)

The elemental analysis of some plant samples have been carried out in Trabzon region (Turkey) using energy-dispersive X-ray fluorescence (EDXRF) spectrometry. We have analyzed plant samples for nine stations using 1.85 GBq 55Fe radioactive sources. We have found that potassium and calcium within 0.3-1.4% and 0.3-2.8% were present in concentration in plants for every station, respectively. The concentration of Cl and Ti generally changed according to the plant species and the sampling station.

2006-12-01

495

Cutaneous leishmaniasis associated with jungle training.  

Science.gov (United States)

In November 1977, 627 soldiers belonging primarily to the First Battalion, 82nd Airborne Division, stationed at Fort Bragg, were sent to the Canal Zone, Panama, for jungle warfare training. A medical surveillance program incorporating pre- and post-evaluations over a 6-month period with dermatologic examinations, questionnaires, and serologic tests was established. Ten cases of cutaneous leishmaniasis (1.6/100 men) were diagnosed by positive Leishmania culture. The demonstrated lack of sensitivity and specificity of the indirect fluorescent antibody test and the direct agglutination test render these serological methods useless as diagnostic screening methods in the early stages of this disease. PMID:7406101

1980-07-01

496

Coincidence measurements of M-shell excitation in slow Xe-Xe collisions  

Energy Technology Data Exchange (ETDEWEB)

Ion-photon and ion-Auger-electron coincidence measurements have been performed to study the impact parameter dependence of Xe M-shell excitation in 1.05 MeV Xe/sup 3 +/-Xe collisions. The experimental results are found to be consistent with the prediction of the molecular orbital model of atomic collisions. The average fluorescence yield for the Xe M shell is found to be strongly dependent on the impact parameter. This is ascribed to the production of highly charged Xe ions in close collisions.

1982-07-14

497

Application of radionuclide X-ray fluorescence analysis in determining lanthanum content in tungsten and in iron by internal standard technique  

Energy Technology Data Exchange (ETDEWEB)

The use of the method is described on powder samples before and after sintering with a La content of up to 1%. For excitation of the K series of La a /sup 241/Am source with an activity of 1.11 GBq was used. The obtained results showed that the method is sufficiently accurate (error 7%) at a short period of measurement (100 s). It gives satisfactory results even in the comparison of the experimental relative count rate and the theoretically calculated value despite the fact that the analytical signal comes from the sample surface.

1983-05-01

498

Application of radionuclide X-ray fluorescence analysis in determining lanthanum content in tungsten and in iron by internal standard technique  

International Nuclear Information System (INIS)

The use of the method is described on powder samples before and after sintering with an La content of up to 1%. For excitation of the K series of La a _2_4_1Am source with an activity of 1.11 GBq was used. The obtained results showed that the method is sufficiently accurate (error 7%) at a short period of measurement (100 s). It gives satisfactory results even in the comparison of the experimental relative count rate and the theoretically calculated value despite the fact that the analytical signal comes from the sample surface. (Ha).

1983-01-01

499

Analysis of o-tyrosine as a method for the identification of irradiated chicken and the comparison with other methods (analysis of volatiles and ESR-spectroscopy)  

Energy Technology Data Exchange (ETDEWEB)

With the mentioned method to analyse O-tyrosine with HPLC/fluorescence-detection, the irradiation of chicken meat can be determined in a simple and fast way. The formation of o-tyrosine is proportional to the applied dose but because it is also depending on the applied dose rate and the temperature during the irradiation, it is not possible to control the irradiation dose. Since unirradiated chicken can contain little amounts of o-tyrosine and to confirm some results, a second method is needed. Together with one of the other mentioned methods (analysis of the volatiles or esr-spectroscopy) it is possible to recognize irradiated chicken with a high security. (author).

1990-01-01