Objective: To evaluate the quality and usefulness of direct digitalradiography system in roentgenogram of chest in clinical practice. Methods: 1000 cases of chest roentgenograms with digitalradiography and high kV conventional radiography were selected for analysis by 3 senior radiologists. Results: 1. With digitalradiography system, the quality of chest film was assessed as grade A in 50.6%, grade B in 38.5%, grade C in 10.9%, and no waste film. 2. With conventional high kV radiography, the quality of chest film was assessed as grade A in 41.1%, grade B in 44.1%, grade C in 13.3%, and waste film in 1.5%. The direct digitalradiography was statistically superior to the conventional high kV radiography. 3. The fine structure of the lungs could be revealed ...
Digital imaging techniques such as Digital Image Intensifier Radiography and Digital Storage Phosphor (Selenium) Radiography are replacing conventional film-screen radiography more and more. The aim of this development is the extension of diagnostic capabilities and the reduction of side effects such as radiation dose. Conventional film-screen radiography and digitalradiography are very different ways of imaging. For digitalradiography specific post-processing is the link between imaging conditions and film documentation. Optimisation of the images includes new possibilities of post-processing and a broad range for variation of the dose. Especially in fluoroscopy, dose can be reduced significantly by new technical features like pulsed fluoroscopy. For ...
Digital imaging techniques such as Digital Image Intensifier Radiography and Digital Storage Phosphor (Selenium) Radiography are replacing conventional film-screen radiography more and more. The aim of this development is the extension of diagnostic capabilities and the reduction of side effects such as radiation dose. Conventional film-screen radiography and digitalradiography are very different ways of imaging. For digitalradiography specific post-processing is the link between imaging conditions and film documentation. Optimisation of the images includes new possibilities of post-processing and a broad range for variation of the dose. Especially in fluoroscopy, dose can be reduced significantly by new technical features like pulsed fluoroscopy. For ...
Computed radiography (CR) systems use a photostimulable phosphor plate enclosed in a cassette. In CR, image acquisition is a two-stage process wherein image capture and image read out are done separately. Direct digitalradiography (DR) systems, on the other hand, use detectors that have a combined image capture and image read out capability. DR systems are also called as DDR or ddR systems by some vendors. This article focuses on DR systems
Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. ...
Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. Measurement of the MTF, NPS and DQE can ...
Digitalradiography for diagnosis of chest diseases using Fuji Computed Radiography (FCR) was evaluated. The results were as follows; 1. Compared to the conventional chest X-ray films, various types of image enhancement could be made by manipulation of the digital information such as tone conversion, spatial frequency modification etc. 2. Digitalradiography lessens the X-ray exposure dose and will ultimately permit speedy transmission of image data from outlying clinics to central processing hospitals. 3. Digital radiographic images are useful in chest X-ray diagnosis especially in mass surveys for lung cancer and in primary care medicine because of its full imaging capability. (author).
The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digitalradiography were used. For the direct digitalradiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver ...
The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digitalradiography were used. For the direct digitalradiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver ...
Wall thickness measurement of pipe is very important of the structural integrity of the industrial plant. However, the radiography method has an advantage because the ability of penetrating the insulated pipe. This will have economic benefit for industry. Moreover, the era of digitalradiography has more advantages because the speed of radiographic work, less exposure time and no chemical used for film development. Either the conventional radiography or digital radiology, the wall thickness measurement is using the tangential radiography technique (TRT). In case, of a large diameter, pipe (more than inches) the determination maximum penetration wall thickness must be taken into the consideration. This paper is revisited the mathematical derivation of the determination of wall thickness measurement based on tangential radiography technique ...
Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management.
Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management. (orig.).
A method for the determination of stereotaxic coordinates in radiography, e.g. angiography, pneumoencephalography or digital vascular radiography, is described. A special localization frame containing radiopaque structures and scales defines a diagnostic coordinate system. This frame is fixed to the X-ray-table prior to the radiographic procedure and two projections are obtained at arbitrary angles to each other. The focus-film distances do not have to be fixed. The target coordinates are then determined either by a simple graphical procedure or with the use of a digitizing x-y-table, by a computer. With the computer method the films are placed on the digitizing table and the target and a few reference points are marked using a cursor. From the relative positions the computer calculates the coordinates. With the special head fixation system, coordinates of structures visualized in ...
In dual-energy projection radiography with double exposures, rapid energy switching is mandatory to eliminate motion artifacts, but it is costly for use in a clinical environment. We developed a system with practical exposure intervals at reasonable cost by modifying a condenser-type X-ray generator. A commercially available system for digitalradiography (Fuji Computed Radiography, FCR) was used to subtract images. This report dealt with technical factors to obtain adequate kV and mAs settings in this technique.
In dual-energy projection radiography with double exposures, rapid energy switching is mandatory to eliminate motion artifacts, but it is costly for use in a clinical environment. We developed a system with practical exposure intervals at reasonable cost by modifying a condenser-type X-ray generator. A commercially available system for digitalradiography (Fuji Computed Radiography, FCR) was used to subtract images. This report dealt with technical factors to obtain adequate kV and mAs settings in this technique. (author).
To evaluate the usefulness of portable chest radiographs by Fuji computed radiography (FCR) in ICU, FCR radiographs of 56 patients who were admitted to General Intensive Care Unit of Keio University Hospital were compared with the conventional portable images. Because FCR could show two differently processed images in one film and allowed a wide range of image reproduction, visualization of the trachea, bone soft tissues and catheters by FCR was easier than that by the conventional radiography. Repeated radiographs by FCR had similar optical densities and limited exposure errors. Furthermore, radiation was reduced than that of the conventional radiography. In conclusion, FCR is thought to be a useful technique for portable chest radiography in ICU patients. (author).
To evaluate the usefulness of portable chest radiographs by Fuji computed radiography (FCR) in ICU, FCR radiographs of 56 patients who were admitted to General Intensive Care Unit of Keio University Hospital were compared with the conventional portable images. Because FCR could show two differently processed images in one film and allowed a wide range of image reproduction, visualization of the trachea, bone soft tissues and catheters by FCR was easier than that by the conventional radiography. Repeated radiographs by FCR had similar optical densities and limited exposure errors. Furthermore, radiation was reduced than that of the conventional radiography. In conclusion, FCR is thought to be a useful technique for portable chest radiography in ICU patients. (author).
Present day mammography has not been able to make use of the advantages of digital luminescence radiography because of the limited spatial resolution. The recent development of electromagnetic focusing X-ray tube with effective focal spot sizes from 0.04 to 0.12 mm allows radiographic direct magnification with less geometric blur. It is now possible to combine direct magnification mammography with digital luminescence radiography. By combining high quality storage phosphor screens with an HQ-workstation a spatial resolution of 8 lp/mm is possible for 1.7-fold magnification. For 4-fold spot magnification views spatial resolution can be theoretically increased to approx. 20 lp/mm. One important advantage of digitalradiography is the possibility of image-postprocessing. This article presents two sets of standard parameters and three sets of image dependent ...
The image quality of digital luminescent radiography (DLR) is sufficient for routine biplane chest radiography and for follow-up studies of heart size, pulmonary congestion, coin lesions, infiltrations, atelectasis, pleural effusions, and mediastinal and hilar lymph node enlargement. Chest radiography in the intensive care unit may in most cases be performed using the DLR technique. there is no need for repeat shots because of incorrect exposure, and the position of catheters, tubes, pacemakers, drains and artificial heart valves, the mediastinum, and the retrocardiac areas of the left lung are more confidently assessed on the edge-enhanced DLR films than on conventional films. Nevertheless, DLR is somewhat inferior to conventional film-screen radiography of the chest as it can demonstrate or rule out subtle pulmonary interstitial disease less confidently. There is no reduction of ...
An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.
An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.
The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)
AIM: To define the value of digitalradiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image ...
AIM: To define the value of digitalradiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image ...
In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).
27 cases including 7 outpatients, underwent intraarterial DSA using 4-F nylon catheter, by transbrachial arterial approach. Much of DSAs were performed in Fuji Computed Radiography (FCR), which has high spatial resolution. In all cases, image quality satisfied clinical demands. No major complication occured in this series. Transbrachial arterial digital subtraction angiography is excellent and safe method for screening of vascular disease. (author).
We have investigated the detection performance of GaAs detectors made with different thickness and contact geometries. A comparison is made between these detection capabilities and the imaging requirements for the following medical applications: digital mammography, digital chest radiography and nuclear medicine. Experimental results and preliminary images are presented and discussed. (author)
Fuji Computed Radiography (FCR) is a new system of digitalradiography that is based on the latest computer technologies. We applied this FCR system to the X-ray diagnosis of the laryngeal disease. Twenty patients with various laryngeal diseases were evaluated by both FCR frontal tomography and conventional screen-film frontal tomography under the same exposure condition. Both tomograms were then compared on the subject of the clarity of delineation of laryngeal structures. As the result, FCR tomograms revealed the feature of the laryngeal lumen and cartilages more clearly than conventional tomograms. In addition, energy subtraction method, which is one of FCR image processing systems, was presented as a new technical procedure to extinguish cervical spine shadows in plain anteroposterior laryngeal X-photograph. We stress that FCR system is the suitable procedure for X-ray analysis of laryngeal diseases, especially in the ...
Visualization of a liquid metal flow and image processing methods to measure the vector field are carried out by real-time neutron radiography. The JRR-3M real-time thermal neutron radiography facility in the Japan Atomic Energy Research Institute was used. Lead-bismuth eutectic was used as a working fluid. Particles made from a gold-cadmium intermetallic compound (AuCd{sub 3}) were used as the tracer for the visualization. The flow vector field was obtained by image processing methods. It was shown that the liquid metal flow vector field was obtainable by real-time neutron radiography when the attenuation of neutron rays due to the liquid metal was less than l/e and the particle size of the tracer was larger than one image element size digitized for the image processing. (orig.).
Visualization of a liquid metal flow and image processing methods to measure the vector field are carried out by real-time neutron radiography. The JRR-3M real-time thermal neutron radiography facility in the Japan Atomic Energy Research Institute was used. Lead-bismuth eutectic was used as a working fluid. Particles made from a gold-cadmium intermetallic compound (AuCd_3) were used as the tracer for the visualization. The flow vector field was obtained by image processing methods. It was shown that the liquid metal flow vector field was obtainable by real-time neutron radiography when the attenuation of neutron rays due to the liquid metal was less than l/e and the particle size of the tracer was larger than one image element size digitized for the image processing. (orig.).
In neutron radiography, as in other forms of NDE, it is sometimes desirable to observe dynamic events. This need has generated increased interest in real-time neutron radiography systems. As in other forms of radiography, a standard method for measuring the image forming capability of real-time systems is necessary in order to compare the various methods and systems used. A technique which has been used extensively in general photography and has been applied in the characterization of several screen-film combinations used in conventional neutron radiography is to determine the imaging system's modulation transfer function (MTF). This gives a graphical representation of the system's spatial resolution capabilities and was therefore chosen as the method for evaluation of the real-time neutron radiography facility at the University of Missouri Research Reactor (MURR). The method used ...
A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digitalradiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above mentioned image processings are adopted, ...
A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digitalradiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above mentioned image processings are adopted, ...
Objective: To investigate the relationship between exposure dose and image quality for a direct digitalradiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly different. Conclusion: The image quality of direct digitalradiography system is improved as ...
Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the cervicothoracic region, where it is usually difficult to obtain clear cervicothoracic films in conventional ...
Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digital image processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images. (author).
As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness.
As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness. (author).
The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)
Objective: To discuss the clinical application value of dual energy subtraction (DES) in direct digitalradiography of chest. Methods: 83 cases of chest digitalradiography(DR) using double-energy subtraction (DES) were randomly selected, and three posterior-anterior (PA) chest films (standard image, bone image and soft tissue image) were obtained in each case, which is so called 'bone and soft tissue separated' technology. Results: With the aid of double energy subtraction (DES), the bony chest was subtracted, the sensitivity and specificity of pulmonary calcification were improved, and sensitivity of pulmonary nodes was also improved, enhancing the distinction between pulmonary benign or malignant lesions, enlightening the diagnosis of chest cage lesions, and showing a clear superiority in the detection of pulmonary nodes comparing to common chest films. The double energy subtraction (DES) films ...
Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical conditions were determined. (author).
Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical conditions were determined. (author).
Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction technique, and so on. For the real-time application a contouring operation and an averaging approach can also be utilized effectively.
Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction technique, and so on. For the real-time application a contouring operation and an averaging approach can also be utilized effectively. (orig.).
A real-time neutron radiography system was installed at the neutron radiography facility of Sumitomo Heavy Industries where a sub-compact cyclotron is used as a neutron generator and nominal neutron flux was observed as 1.1 x 10"6 n/cm"2/sec. Preliminary tests were made for various kinds of such components as collimators, scintillators, cameras and lenses and the system was chosen to give the highest quality images. Especially for the scintillator screen, screening tests were carried out for compounds of LiF/ZnS(Ag) and Gd_2O_3/ZnS(Ag) by radiographic film method. The neutron radiography image was converted to fluorescent images by means of the converter and observed by a SIT type TV camera. The video signal was directly displayed on a CRT or after processed with digital image processing devices. The characteristics of this system as for the resultant resolution are presented together with some actual ...
The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of gray scale and resolved to 240 x 256 picture elements (pixels) on a monochrome CRT, ...
The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of gray scale and resolved to 240 x 256 picture elements (pixels) on a monochrome CRT, ...
The refrigerant two-phase flows in a distributor and a simulated plate heat exchanger with a single passage used in a compression-type refrigerator were visualized by real-time neutron radiography. For a distributor, the liquid fraction in the each tube was measured by some image processing method. On the other hand, for a plate heat exchanger, the two-dimensional distribution of void fraction was measured quantitatively by the umbra method. As a result, it was shown that the dynamic behaviors of refrigerant at the inlet of the section strongly affected on the performance, that is, a distribution performance of a distributor and a liquid distribution in a plate heat exchanger. (author)
Several neutron radiography systems designed to view transient processes on a real-time basis have been developed. With the advent of these different real-time systems comes the necessity to develop a means to quantitatively evaluate and compare these systems. A suitable method for measuring the resolution capabilities of the image-forming system is the determination of the modulation transfer function (MTF). The MTF is a measure of an imaging system's ability to reproduce the spatial frequencies present in an image. The system in use at the University of Missouri Research Reactor is described. (Auth.).
Real-time neutron radiography was demonstrated to be a viable and useful tool in studying water flow in unsaturated media. The experiment was designed to test the method for following water flow. The wetting front advance, water-flow patterns, and neutron attenuation density were observed in a 7.7-cm diameter sand column. The advance was fit with a simple i = A t/sup B/ equation yielding an excellent correlation. Theoretical calculations presented estimate the minimum and maximum detectable water content in various sizes of columns. The ability of real-time neutron radiography to allow both qualitative and quantitative spatial and time measurements to be made in an nonintrusive manner was demonstrated.
Real-time neutron radiography was demonstrated to be a viable and useful tool in studying water flow in unsaturated media. The experiment was designed to test the method for following water flow. The wetting front advance, water-flow patterns, and neutron attenuation density were observed in a 7.7-cm diameter sand column. The advance was fit with a simple i = A t/sup B/ equation yielding an excellent correlation. Theoretical calculations presented estimate the minimum and maximum detectable water content in various sizes of columns. The ability of real-time neutron radiography to allow both qualitative and quantitative spatial and time measurements to be made in an nonintrusive manner was demonstrated.
Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was evaluated by 19 radiologists, using ROC ...
Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was evaluated by 19 radiologists, using ROC ...
Neutron radiography (NR) is a useful non-destructive method for determination of hydrogen content in various building and technical materials. Monitoring of transport processes of moisture and hydrogenous liquids in porous building materials is enabled by fast, quasi-real-time NR methods based on novel imaging plate neutron detectors (IP-NDs). Hydrogen content in the samples is determined by quantitative analysis of measured profiles of neutron attenuation in the samples. Detailed description of quantitative NR method is presented by the authors in another accompanying contribution at this conference. Deterioration of building materials is originated by different processes that all require presence of water therefore it is essential to limit or prevent the transport of water through the porous material. In this presentation, results of a study of clay brick impregnation by silicone based hydrophobic agents will be ...
Results of ongoing research project at the McMaster Nuclear Reactor Facility on real-time neutron radiography for the visualization of interfacial geometry, movements and phase distributions in gas-liquid and gas-liquid-metal multi-phase flows are presented. Experiments were conducted with bubble column tubes with boiling liquid nitrogen, air-water and air-mercury mixtures. Discussions are also focused on air-water flowing within a tube containing a CANDU type 37 rod fuel bundle assembly positioned both horizontally and vertically. Computer processing using a digital image format to enhance the real-time images was used. Imaging techniques include frame averaging, background substraction, edge enhancement (spatial filtering), contrast enhancement and video densitometry. (orig.).
Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digital image processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images.
The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose of developing a system with higher sensitivity, consideration of neutron statistics ...
The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose of developing a system with higher sensitivity, consideration of neutron statistics ...
Objective: To compare the efficiency of dual energy subtraction and conventional direct digitalradiography in signal detecting ability. Methods: 200 plastic balls which were 4 mm in diameter were taken as signals and were placed on a 10 cm thick plastic board and the right upper thorax of a healthy volunteer. The signals were examined by DES and CDR separately and were estimated by 3 radiologists with 5-value-differentiation method. ROC curve analysis was made by ROC kit software. Results: when signals on plastic board were detected by CDR and DES, ROC curve analysis indicated that there was no significant difference (P=0.4851 > 0.05, two-tailed) between the area under the ROC curves of the two methods (Az=0.9931 for CDR and Az=0.9879 for DES). The difference was significant (P=0.0002 <0.01, two-tailed) between the area under the ROC curves of CDR and DES (Az=0.7276 for CDR and Az=0.8561 for DES), when the signals on the right upper ...
Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and displayed four images ...
Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR ...
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain quantitative information on the object being imaged.
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain quantitative information on the object being imaged. (orig.).
Initial major applications of neutron radiography (NR) to nuclear engineering were nondestructive inspections of nuclear fuel, control rods, reactor materials and some other components. Increase in the available neutron flux over 10{sup 8} n/cm{sup 2}s at the JRR-3M thermal neutron radiography facility (TNRF) in 1991 has expanded the application field to the dynamic but clear imaging of moving objects and fluid phenomena. The JRR-3M TNRF is facilitated with three major imaging systems, being characterized by spatial and/or temporal resolutions: 1. Static neutron radiography (SNR), 2. real-time neutron radiography (RNR) with an imaging rate of 30 frames/s and 3. High-frame-rate neutron radiography (HFRNR). SNR has been used for three-dimensional visualization of air-water two-phase flows in a simulated rod bundle. Three-dimensional computed tomography clearly illustrated average void ...
Present day mammography has not been able to make use of the advantages of digital luminescence radiography because of the limited spatial resolution. The recent development of electromagnetic focusing X-ray tube with effective focal spot sizes from 0.04 to 0.12 mm allows radiographic direct magnification with less geometric blur. It is now possible to combine direct magnification mammography with digital luminescence radiography. By combining high quality storage phosphor screens with an HQ-workstation a spatial resolution of 8 lp/mm is possible for 1.7-fold magnification. For 4-fold spot magnification views spatial resolution can be theoretically increased to approx. 20 lp/mm. One important advantage of digitalradiography is the possibility of image-postprocessing. This article presents two sets of standard parameters and three sets of image dependent ...
This paper describes Fuji computed radiography (FCR) of Fuji Film for NDT (non-destructive testing). Imaging plate (IP) is a two-dimensional detector of X-ray, and shows higher photographic sensitivity than X-ray film. The output emission of IP provides a good linear relationship to X-ray intensity in a wide intensity range. When this emission can be digitized, the X-ray intensity can be also digitized. IP is applied to NDT as an inspection using X-ray. FCR provides higher photographic sensitivity than the conventional X-ray film method, which results in one-fifth to one-twentieth of irradiation time. Images with stable density can be obtained independent of the intensity. Since IP has a wide dynamic range, the variation of X-ray intensity of 1:500 can be expressed in a single image by single shot. High density record including 1000 images can be done using a 5.25 inch optical disk through the digital ...
Objective: An evaluation of the application of DR in thoracic spine and a comparative study of the DR with the conventional radiography. Methods: DR images and the conventional radiogram of 89 cases respectively were evaluated by 3 vice-consultant doctors and 2 chief technicians. Statistics was processed with 2 categories: (1) images were classified into grade A, B, C and condemned according to the image quality; and (2) thoracic spine are divided into upper, middle and lower portions, in which the rate of successful imaging were compared respectively. Results: The image quality of DR: 74. 1% images in grade A, 20.2% in grade B, 5.7% in grade C, and no image condemned. Conventional radiogram: 45% images in grade A, 41.6% in grade B, 11.2% in grade C, and 2.2% images condemned. The successful imaging rate in each portion: DR films 87.6% in upper thoracic spine, 100% in middle portion, and 76.4% in lower portion with DR. While the rate was 15.3% in upper portion, ...
A recent study reported the results of an exploratory study of alterations of the quantitative sleep profile due to the effects of a digital mobile radio telephone. Rapid eye movement (REM) was suppressed, and the spectral power density in the 8--13 Hz frequency range during REM sleep was altered. The aim of the present study was to illuminate the influence of digital mobile radio telephone on the awake electroencephalogram (EEG) of healthy subjects. For this purpose, the authors investigated 34 male subjects in a single-blind cross-over design experiment by measuring spontaneous EEGs under closed-eyes condition from scalp positions C{sub 3} and C{sub 4} and comparing the effects of an active and an inactive digital mobile radio telephone (GSM) system. During exposure of nearly 3.5 min to the 900 MHz electromagnetic field pulsed at a frequency of 217 Hz and with a pulse width of 580 {micro}s, the ...
We performed a comparative study of digitally and conventionally acquired images in gastrointestinal examinations. Radiation dose and spatial resolution were determined in a water phantom. In 676 examinations with either conventional or digital imaging (system: Diagnost 76, DSI) the number of images and the duration of the fluoroscopy time were compared. 101 examinations with digital as well as conventional documentation were evaluated by using 5 criteria describing the diagnostic performance. The entrance dose of the DSI is 12% to 36% of the film/screen system and the spatial resolution of the DSI may be better than that of a film/screen system with a speed of 200. The fluoroscopy time shows no significant difference between DSI and the film/screen technique. In 2 of 4 examination modes significantly more images were produced by the DSI. With exception of the criterion of edge sharpness, DSI yields a significantly inferior ...
A new microdensitometry method for quantitative assessment of bone mineral content using Fuji computed radiography (FCR) was developed and the results were compared with those obtained by the conventional film-screen method. Using both methods, X-ray pictures of the 2nd metacarpal bone were taken with a reference aluminum step wedge in nine normal subjects and nine parameters representing the width and density of bone marrow and cortex were calculated in middle of the bone shaft. Interobserver reproducibility assessed for three parameters was significantly higher in the FCR method than the conventional one. The value of {Sigma}GS computed by the FCR method, that is equivalent to the net bone density of the transverse section of the shaft, showed higher correlation with the one obtained by computed tomography in comparison with the conventional method. In our FCR method, moreover, interobserver reproducibility and accuracy was improved by ...
A new microdensitometry method for quantitative assessment of bone mineral content using Fuji computed radiography (FCR) was developed and the results were compared with those obtained by the conventional film-screen method. Using both methods, X-ray pictures of the 2nd metacarpal bone were taken with a reference aluminum step wedge in nine normal subjects and nine parameters representing the width and density of bone marrow and cortex were calculated in middle of the bone shaft. Interobserver reproducibility assessed for three parameters was significantly higher in the FCR method than the conventional one. The value of #SIGMA#GS computed by the FCR method, that is equivalent to the net bone density of the transverse section of the shaft, showed higher correlation with the one obtained by computed tomography in comparison with the conventional method. In our FCR method, moreover, interobserver reproducibility and accuracy was improved by ...
The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the {gamma}-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10{sup 6}n/cm{sup 2}s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/{gamma} ratio {approx} 10{sup 6}n/cm{sup 2}mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame ...
The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the #gamma#-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10"6n/cm"2s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/#gamma# ratio #approx# 10"6n/cm"2mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame grabber and a ...
Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and displayed four images ...
An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.
... Science, Computer Vision, Digital Government, Digital Libraries, Digital Society and Technologies ... for Robust Intelligence, Digital Government, and Digital Libraries and Archives. In subsequent years ...
The radionuclide X-ray fluorescence analyzer consists of a source changer and a sample changer. "5"5Fe, "1"0"9Cd and "2"4"1Am are used as excitation sources. The radiation is detected with a semiconductor Si(Li) detector. The complete assembly of the apparatus consists of an imagine unit, a keyboard, a floppy disc drive, a printer, a console and a rack with analog and digital electronics. Its multichannel amplitude analyzer consists of power supplies, a high voltage supply, a linear amplifier, an analog-to-digital converter and a computer. The technical specifications are given. The control and data processing system is controlled with an MHB 8080A microprocessor. Software for semiconductor gamma spectrometry and for quantitative gamma spectrometry will be supplied with the equipment. (E.S.). 3 figs., 4 refs.
A device for detecting neutrons includes a semi-insulated bulk semiconductor substrate having opposed polished surfaces. A blocking Schottky contact comprised of a series of metals such as Ti, Pt, Au, Ge, Pd, and Ni is formed on a first polished surface of the semiconductor substrate, while a low resistivity ("ohmic") contact comprised of metals such as Au, Ge, and Ni is formed on a second, opposed polished surface of the substrate. In one embodiment, n-type low resistivity pinout contacts comprised of an Au/Ge based eutectic alloy or multi-layered Pd/Ge/Ti/Au are also formed on the opposed polished surfaces and in contact with the Schottky and ohmic contacts. Disposed on the Schottky contact is a neutron reactive film, or coating, for detecting neutrons. The coating is comprised of a hydrogen rich polymer, such as a polyolefin or paraffin; lithium or lithium fluoride; or a heavy metal fissionable material. By varying the coating thickness and electrical settings, neutrons at specific ...
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In computed radiography, image processing (tone scale modification and edge enhancement) is possible, and is advantageous portal ...
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In computed radiography, image processing (tone scale modification and edge enhancement) is possible, and is advantageous portal ...
Computed tomography (CT) has been incorporated in an industrial Diode-Array DigitalRadiography (DADR) system. An input data size of 512 pixel points x 400 projections yielded a 400x400 output image matrix. Reconstruction algorithms used are the filtered backprojection (FBP) and the direct Fourier reconstruction (DFR). Various filters were used in the FBP reconstruction process and their effects on image quality were evaluated. A spatial resolution of 100 {mu}m was measured with a block of plates and a minimum detectable feature size in the range of 10-100 {mu}m was measured using thin wires. Industrial specimens imaged have included ceramic samples, ball bearings and integrated circuits. A number of engineering problems have been solved, such as adjustment of the X-ray source, centering of the rotator spindle in the view field and beam-hardening corrections. (orig.).
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the reconstructed image. The image quality could be satisfactory to ...
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the reconstructed image. The image quality could be satisfactory to ...
Currently daily quality control (QC) tests for mammography systems are generally evaluated by using visual analysis phantoms, which of course means subjective measurement. In our study, however, we evaluated a novel digital phantom, the 1Shot Phantom M plus (1Shot Phantom), together with automatic analysis software dedicated for mammography systems using Fuji computed radiography (FCR). The digital phantom enables objective evaluation by providing for actual physical measurement rather than subjective visual assessment. We measured contrast to noise ratio (CNR), image receptor homogeneity, missed tissue at chest wall side, modulation transfer function (MTF), and geometric distortion utilizing the 1Shot Phantom. We then compared the values obtained using the 1Shot Phantom with values obtained from the European guidelines and International Electrotechnical Commission (IEC) standards. In addition, we evaluated the convenience ...
Fuji Computed Radiography (FCR) utilizes imaging plates of scanning lazer stimulated luminescence. FCR can be used for intravenous digital subtraction angiography (IVDSA) and for intraarterial studies because of tis high contrast and spatial resolution. Pixel size of the imaging plates for angiography is 0.2 mm. Experimentally, it could demonstrate a vessel 1 mm in diameter with a contrast of 0.1, when opacified with a contrast medium of 3 % iodine concentration, and could image a vessel 3 mm in diameter with contrast of 0.1, when opacified with 1 % contrast medium. A 20 % stenosed portion of a vessel 3 mm in diameter was identified when opacified with 3 % contrast medium, and a 20 % stenosed portion of a vessel 2 mm in diameter was identified when opacified with 10 % contrast medium. In 105 IVDSA examinations of 75 patients, FCR was superior to Digital Fluorography (DF) in spatial resolution, size of examination field, ...
We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curve, modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ)) for Cannon's flat-panel detector (FPD), Fuji computed radiography (FCR) and screen-film (S/F) systems, respectively. First, the digital and overall characteristic curves of FPD and FCR systems were more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of FPD system were better than those of FCR system a little at lower spatial frequencies than 0.8 mm"-"1, but the overall MTF of FPD and FCR systems were worse than that of S/F system a little at all spatial frequencies. Third, the digital and overall WS of FPD system were similar or better than those of FCR system, but the overall WS of FPD and FCR systems were worse than that of S/F system. Fourth, the pre-sampling and overall ...
We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curve, modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ)) for Cannon's flat-panel detector (FPD), Fuji computed radiography (FCR) and screen-film (S/F) systems, respectively. First, the digital and overall characteristic curves of FPD and FCR systems were more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of FPD system were better than those of FCR system a little at lower spatial frequencies than 0.8 mm{sup -1}, but the overall MTF of FPD and FCR systems were worse than that of S/F system a little at all spatial frequencies. Third, the digital and overall WS of FPD system were similar or better than those of FCR system, but the overall WS of FPD and FCR systems were worse than that of S/F system. Fourth, the pre-sampling ...
Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point source results in a phase contrast too narrow for detection with CR. In addition to phase contrast improving image quality, a re-scaling effect ...
In 576 patients quantitative scintigraphy of the sacroiliac joints and the spinal cord with "9"9"mTc-pyrophosphate was performed. 328 were patients with proven ankylosing spondylitis according to the New York criteria. 120 were patients with a clinically and roentgenologically suspected ankylosing spondylitis and 128 persons formed a healthy control group. The count rate in small regions of interest (ROI) in the sacroiliac joints, the spinal cord and the os sacrum were compared on the basis of indexes. The scintigraphic data of patients with ankylosing spondylitis were compared with the healthy control group and with the radiographic findings and radiologic staging of the disease. In a longitudinal follow-up study during 1 to 6 years these investigations were continued together with clinical and roentgenological checks. Quantitative bone scintigraphy provides characteristic indexes for ankylosing spondylitis, indicating the increased mineral ...
In 620 patients quantitative bone scintigraphy with "9"9"mTc pyrophosphate of the sacroiliac joints and of the spine was performed: 365 patients with confirmed ankylosing spondylitis, 125 patients with clinical radiological suspicion for ankylosing spondylitis (probable Bechterev) and control group of 130 healthy individuals. By comparison of the activity in zones of interest of the sacroiliac joints, the spine and sacrum, the following indices were determined: sacroiliac (separately for the left and right sacroiliac joints), index D_1_0/sacrum, index L_4/sacrum and index C_7/sacrum. The scintigraphic finding was compared to the X-ray one and to the radiological stage of the disease. A long-term follow-up of the patients was carried out during 1-6 years with scintigraphic, X-ray and clinical investigations. Emphasis was laid upon the posibilities for quantitative scintigraphy for early diagnostics of ankylosing spondylitis. The combination of ...
The purpose of this study was to clarify the benefits of digital lateral chest radiogram. In the basic study, the modulation transfer factor (MTF) and the wiener spectra (WS) of conventional screen film (CSF) and Fuji computed radiography (FCR) were measured. The visibility of the simulated nodules on FCR using 3 human bodies was subjectively compared with that on CSF by 13 observers. In the clinical study, the visibility of the normal structures on FCR was subjectively compared with that on CSF using 50 lateral chest radiograms by 10 observers. The diagnostic performance to detect pulmonary nodules on FCR was also compared with that on CSF using each 30 positive and negative cases by 8 observers. In the basic study, the MTF of FCR was superior to that of CSF, and the WS of FCR displayed in half size was superior to that of CSF. In all exposure conditions, the visibility of the nodules on FCR in the pulmonary apex was inferior to that on CSF, ...
The purpose of this study was to clarify the benefits of digital lateral chest radiogram. In the basic study, the modulation transfer factor (MTF) and the wiener spectra (WS) of conventional screen film (CSF) and Fuji computed radiography (FCR) were measured. The visibility of the simulated nodules on FCR using 3 human bodies was subjectively compared with that on CSF by 13 observers. In the clinical study, the visibility of the normal structures on FCR was subjectively compared with that on CSF using 50 lateral chest radiograms by 10 observers. The diagnostic performance to detect pulmonary nodules on FCR was also compared with that on CSF using each 30 positive and negative cases by 8 observers. In the basic study, the MTF of FCR was superior to that of CSF, and the WS of FCR displayed in half size was superior to that of CSF. In all exposure conditions, the visibility of the nodules on FCR in the pulmonary apex was inferior to that on CSF, ...
To evaluate the diagnostic performance of commercially available CRT monitors used in a teleradiology system by determining the rate of detection of simulated lung nodules. Three types of CRT monitors were tested in the observation study. They had matrix sizes of 1024 x 768 (16 inches, color), 1024 x 768 (20 inches, color) and 1600 x 1125 (24 inches, black and white). Twenty chest radiographs were obtained by Fuji computed radiography (FCR) of an anthropomorphic chest phantom with ten simulated nodules on its surface. These FCR films were digitized by a film digitizer with 125 DPI (1024 x 1024 matrix sizes) and 12 bit gray scales, and the image data were transferred from Shinshu University Hospital to other hospitals where interpretation was carried out by the radiologists. Ten radiologists of three hospitals were asked to interpret independently both the original FCR films and the images shown on the CRT monitors and to ...
A vessel phantom suitable for evaluation of spatial and contrast resolution of FCRDSA (Fuji Computed Radiography, digital subtraction angiography) has been developed and used for determining resolution. The effects of iodine concentration, low dose exposure, and acryl thickness on the resolution were evaluated in FCRDSA, and FCRDSA images were compared with film substraction with use of this phantom. It has been proven that limitation of resolution of FCRDSA was 5 % 1 mm and about 1/4 dose exposure compared with conventional film exposure was clinically acceptable. Dye dilution method was useful to determine a program of IVDSA with imaging plate. It has been proven that time to appearance and time to peak of time-concentration curve of dye dilution method closely correlate to time to appropriate image of DSA in the neck, the chest, and the abdomen. 106 cases of IVDSA and 130 cases of IADSA using FCR in Tohoku University Hospital from January ...
digital libraries, which was identified as a national challenge in the Information ... The linkages between the many digital libraries and information services are ...
This research aims at elucidating thermal hydraulic phenomena by carrying out their visualization and measurement which are difficult by conventional method, utilizing the excellent properties of real time neutron radiography and showing the usefulness of neutron radiography. The experiments were carried out on the visualization and measurement of liquid metal flow and mixed phase flow and the visualization and diagnosis of mixed phase flow equipment. As the achievement in this fiscal year, the image-processing method for visualizing quantitatively the distribution of void fraction in gas-liquid two-phase flow has been devised, therefore, its method and results are reported. For the analysis of multi-dimensional two-phase flow, in order to prepare the model and determine the constitution equation, the data on the multi-dimensional distribution of void fraction are required. Void fraction is defined. The method of image ...
Full text: Introduction. Children, especially premature infants and neonates, are at a much higher risk to obtain an X ray induced disturbance of life - particularly cancer. On the one hand this is due to their longer life expectancy and on the other hand it is due to their higher cell proliferation rate. The paediatric radiology unit of the Inselspital Bern recently installed some of the most advanced X ray equipment nowadays available. It is based on the two latest digital technologies: double read computed radiography (CR) and direct digitalradiography (DR). Only the implementation of these digitalradiography systems permits the digital acquisition and additionally the analysis of acquired data. The systematic analysis of large amounts of biometric data and exposition data is the basis for further dose reduction and a systematic quality ...
Detailed three dimensional wing kinematics and aerodynamic characteristics are experimentally presented for the free flight of a beetle, Allomyrina dichotoma, which has a pair of elytra (fore wings) and hind wings. The kinematic parameters of the wing motion, such as the wing tip trajectory, angle of attack, torsion angle, and camber deformation, are obtained from a 3D reconstruction technique that involves the use of two or three synchronized high-speed cameras to digitize various points marked on the wings. Our data show outstanding characteristics of wing deformation and flexibility in the free flight of the beetle. To find out the mechanism of aerodynamic force, the leading edge vortex (LEV) and trailing edge vortex (TEV) on both elytron and hind wing were observed by using smoke wire visualization and digital particle image velocimetry (DPIV) technique. Qualitative smoke lines in the region of the most intent vortex shedding demonstrate ...
Mammography has emerged as a reliable non-invasive technique for the early detection of breast cancer--the second leading cause of cancer-related mortality among American women. The radiographic appearance of the female breast consists of radiolucent (dark) regions due to fat and radiodense (light) regions due to connective and epithelial tissue. The amount of radiodense tissue can be used as a marker for predicting breast cancer risk. This paper presents the development of an algorithm for estimating the percentage of radiodense tissue in a digitized mammogram. The technique involves determining a dynamic threshold for segmenting radiodense indications in mammograms. Both the mammographic image and the threshold are modeled as Gaussian random variables. This work is intended to support a concurrent study at the Fox Chase Cancer Center (FCCC) exploring the association between dietary patterns and breast cancer risk. Mammograms have been obtained from an existing ...
Terrain attributes derived from digital elevation models have been used widely for mapping soil organic matter (SOM). Among these attributes, the topographic wetness index (TWI), an index for quantitatively indicating the balance between water accumulation and drainage conditions at the local scale, has been shown to correlate with SOM. However, TWIs used in most studies are calculated using a single-flow-direction (SFD) algorithm, which assumes that all water from a grid cell flows into only one neighboring cell. This assumption is not always valid, especially in areas with low relief where movement of water may be divergent. To overcome this SFD limitation, a multiple-flow-direction (MFD) algorithm has been developed, which distributes flow from a grid cell to several downslope neighbors...
The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion from being reached. The fact that all images were of diagnostic quality, however, suggested that the use of the anti-scatter grid was unnecessary. ...
The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion from being reached. The fact that all images were of diagnostic quality, however, suggested that the use of the anti-scatter grid was unnecessary. ...
In order to improve the image quality of linear tomography performed with the Fuji Computed Radiography (FCR) system, we have examined one-dimensional unsharp mask filtering to reduce blur formed in the direction of tomographic swing. We determined a mask size and a weighting factor of the image processing suitable to obtain a quality tomogram. The mask size of 41 x 1 pixels for a 14 x 14'' imaging plate, which modifies the original image date and results in demonstrating a peak frequency at 0.2 cycles/mm for spatial frequency spectrum, is superior in showing fine vessel structures and morphological features of pathology in the lung fields. An additional spatial frequency filtration in the direction perpendicular to the tomographic movement reduces the blur and clearly demonstrates object contours running parallel to the tube movement. However, the additional filtration increases the appearance of noise on the processed image and offsets the ...
The purpose of this study was to investigate the feasibility of a simple deformable phantom as a QA tool for testing and validation of deformable image registration algorithms. A diagnostic thoracic imaging phantom with a deformable foam insert was used in this study. Small plastic markers were distributed through the foam to create a lattice with a measurable deformation as the ground truth data for all comparisons. The foam was compressed in the superior-inferior direction using a one-dimensional drive stage pushing a flat 'diaphragm' to create deformations similar to those from inhale and exhale states. Images were acquired at different compressions of the foam and the location of every marker was manually identified on each image volume to establish a known deformation field with a known accuracy. The markers were removed digitally from corresponding images prior to registration. Different image registration algorithms were tested using this method. Repeat ...
Background: In an effort to standardise radiological practices in the Republic of Ireland, current legislation states that 'written protocols for every type of standard radiological practice shall be established'. In order to fulfil this requirement the Irish Medical Council recommends the protocols issued by the Commission of European Communitees (CEC) for adoption in the country. Whilst this document does provide good guidance with regard to various radiographic factors, patient shielding instructions are notably ambiguous. The aim of this study was to remove some of this ambiguity by defining the optimal method of positioning patient shielding in antero-posterior (AP) and lateral lumbar spine radiographic examinations. These projections were chosen on the basis of their area of coverage being in close to and in some cases including the reproductive organs. They also represent the highest source of collective population dose of any conventional radiographic ...
Background: In an effort to standardise radiological practices in the Republic of Ireland, current legislation states that 'written protocols for every type of standard radiological practice shall be established'. In order to fulfil this requirement the Irish Medical Council recommends the protocols issued by the Commission of European Communitees (CEC) for adoption in the country. Whilst this document does provide good guidance with regard to various radiographic factors, patient shielding instructions are notably ambiguous. The aim of this study was to remove some of this ambiguity by defining the optimal method of positioning patient shielding in antero-posterior (AP) and lateral lumbar spine radiographic examinations. These projections were chosen on the basis of their area of coverage being in close to and in some cases including the reproductive organs. They also represent the highest source of collective population dose of any conventional radiographic examination carried out in ...
A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are used in place of the SIT camera. The computer digitizes the TV ...
A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are used in place of the SIT camera. The computer digitizes the TV ...
The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film arteriogram even with a half concentration of ...
The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film arteriogram even with a half concentration of ...
(USGS Text) Digital line graph (DLG) data are digital representations of cartographic information. DLGs of map features are converted to digital form from ... ...
Quantitativedigital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitative image data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial dynamic range, signal-to-noise ratio and spatial resolution in the imaging system as ...
Objective: To explore the feasibility of real-time monitoring exposure dose and image quality by using the data stored in the DICOM image archive of direct digitalradiography system. Methods: Model TO. 16 was exposed, the current increased gradually from 0.5 to 125 mAs. The displayed number of model A( diameter 11.1 mm), D (diameter 4.0 mm) and J( diameter 0.7 mm) were recorded, and the detect factors (H_T) was also calculated. Images were sent to workstation before the end of DR examination. An automatic procedure was implemented to extract dose data and exposure parameters from the DICOM header file. Maximum, minimum and 3rd quartile values were preinstalled. Mean values exceeding the threshold trigger alarm signal to guide radiologist to explore the cause. Results: When the current of point A was less than 10 mAs and the current of point D and J were less than 16 mAs, the detect factor (H_T) increased with the rise of current. While point A ...
The Neutron Radiography Reactor (NRAD) operated by Argonne National Laboratory is described in this paper. NRAD was designed to allow radiography of highly absorbing reactor fuel assemblies in the vertical position on the routine basis. 7 figs.
Initial clinical experience in gastrointestinal radiography using Fuji Computed Radiography(FCR) system was reported. Image quality of conventional film/screen radiography and FCR system on upper GI series and barium enema was compared. Reflecting wide dynamic range of the system, improved image quality was confirmed, particularity in visibility of fine mucosal pattern(area gastricae), folds and overall contour. High sensor sensitivity of the system could reduce radiation dose requirement significantly. Diagnostically acceptable images were obtained with approximately 1/5 of routine dose for conventional radiography except in cases of lateral view of the rectum. (author).
Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two detectors, respectively and the imaging quality of phantoms. Preliminary results showed that the system is ...
Anti-carcinoembryonic antigen monclonal antibody (MAb) CEA 102 was produced by immunization with purified CEA and the specific accumulation of radiolabeled CEA 102 in colorectal cancers was investigated by autoradiography of sugical specimens using Fuji Computed Radiography (FCR). Five patients with colorectal cancer were injected intravenously with {sup 131}I-labeled intact CEA 102 or its F(ab'){sub 2}. Primary tumor and liver metastases were successfully detected by external scanning with a gamma camera in 4 cases. Autoradiographic study of the surgical specimens using FCR showed predominant localization of {sup 131}I-labeled CEA 102 in primary tumors and liver metastases in all cases. Even a small liver metastasis (0.5 cm) was clearly visualized in the autoradiogram by FCR. The pixel distribution curves of the density of the respective tissues in the autoradiograms by FCR showed the heterogeneity of the distribution of administreted radiolabeled MAb in ...
Anti-carcinoembryonic antigen monclonal antibody (MAb) CEA 102 was produced by immunization with purified CEA and the specific accumulation of radiolabeled CEA 102 in colorectal cancers was investigated by autoradiography of sugical specimens using Fuji Computed Radiography (FCR). Five patients with colorectal cancer were injected intravenously with "1"3"1I-labeled intact CEA 102 or its F(ab')_2. Primary tumor and liver metastases were successfully detected by external scanning with a gamma camera in 4 cases. Autoradiographic study of the surgical specimens using FCR showed predominant localization of "1"3"1I-labeled CEA 102 in primary tumors and liver metastases in all cases. Even a small liver metastasis (0.5 cm) was clearly visualized in the autoradiogram by FCR. The pixel distribution curves of the density of the respective tissues in the autoradiograms by FCR showed the heterogeneity of the distribution of administreted radiolabeled MAb in individual tumors, ...
Quantitative evaluation of CRT and CR observations in indentification of malignancy using phantom and clinical data. A breast phantom and a total of 40 patients were imaged by Fuji computed radiography (FCR). The images were interpreted twice by six radiologists both on CR film (2510 x 2000 pixels x 10 bits, 0.1 mm spatial resolution) and on a CRT monitor (1568 x 1152 pixels x 10 bits, 0.1 mm pixel size with double expansion) with image processing parameters of a toutine (RN 1.0, RE 0.2), for a calcification (RN 9.0, RE 4.0) and for a mass (RN 7.0, RE 2.0). The forty clinical cases included breast diseases with calcifications, masses, and normal breasts. Two-tailed t-test was performed to analyze interpretation of simulated microcalcifications and masses in the phantom. The receiver operating characteristic (ROC) analysis was performed to evaluate clinical cases. In all interpretation studies using both breast phantom and clinical cases, there ...
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere.
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere
The neutron radiography facility was installed at the tangential beam port of the 3 MW TRIGA MARK-II research reactor. In the facility only direct film neutron radiography method is being used. The project involves development of electronic imaging system for real time neutron radiography in the existing facility with the aim of utilizing it for research and industrial applications. In establishing the electronic imaging system for real time neutron radiography the improvements of existing facility were almost done during this period. In parallel, the former facility was used for the research: (a) A study of wood and wood plastic composites with and without additive by using film neutron radiography and (b) A study of jute reinforced polymer composites by using film neutron radiography technique. (author)
Neutron radiography is a non-destructive test method to examine a material by using the dependency of neutron attenuation on the nuclear characteristics of the atoms composing the object material. There are two categories of neutron radiography; static neutron radiography and dynamic neutron radiography. The static neutron radiography is a technique to observe a standing object by using a camera or a film cassette. The dynamic neutron radiography(DNR) is a technique to observe a moving object usually by using a camera. Depending on the camera frame rate, the dynamic neutron radiography is categorized into the real time neutron radiography(RTNR) and the high speed neutron radiography(HSNR). The frame rate for RTNR is 30 frames/s and that for HSNR is usually more that 500 frames/sec. Thus, RTNR is good ...
Neutron radiography is a non-destructive test method to examine a material by using the dependency of neutron attenuation on the nuclear characteristics of the atoms composing the object material. There are two categories of neutron radiography; static neutron radiography and dynamic neutron radiography. The static neutron radiography is a technique to observe a standing object by using a camera or a film cassette. The dynamic neutron radiography(DNR) is a technique to observe a moving object usually by using a camera. Depending on the camera frame rate, the dynamic neutron radiography is categorized into the real time neutron radiography(RTNR) and the high speed neutron radiography(HSNR). The frame rate for RTNR is 30 frames/s and that for HSNR is usually more that 500 frames/sec. Thus, RTNR is good ...
Digital audio sampling is explained, and some of its implications in digital sound applications are discussed. Digital sound equipment is rapidly replacing analog recording devices as the state-of-the-art in audio technology. The philosophy of digital recording involves doing away with the continuously variable analog waveforms and turning the patterns into numbers. A digital recording device rapidly samples the incoming sounds, quantifying the signal into a series of numerical values (binary codes). Although digital sound eliminates many of the traditional analog problems, digital signal processing presents key problems in sampling rates and synchronization. Careful control is necessary to check signals through each step in the audio chain. The advantages of digital audio processing include increased signal-to-noise ...
This paper discusses the stationary neutron radiography system (SNRS) with respect to the component positioning systems (CPSs) and the rationale behind their design. As design work is on-going at science Applications International Corporation, this report gives a current update of progress. The SNRS has four separate radiography bays, Bays 1 through 4. The first three bays have automated positioning systems for real-time and near real-time neutron radiography of aircraft components. Bay 4 has been designed to accommodate components from the solid rocket booster, but will be used first for film radiography of pyrotechnic components.
We present the results of an isophotal shape analysis of three samples of galaxies in the Coma cluster. Quantitative morphology, together with structural and photometric parameters, is given for each galaxy. Special emphasis has been placed on the detailed classification of early-type galaxies. The three samples are: i) a sample of 97 early-type galaxies brighter than m_B = 17.00 falling within one degree from the center of the Coma cluster; these galaxies were observed with CCD cameras, mostly in good to excellent resolution conditions; ii) a magnitude complete sample of 107 galaxies of all morphological types down to m_B = 17.00 falling in a circular region of 50 arcmin diameter, slightly offcentered to the North-West of the cluster center; the images for this and the next sample come from digitized photographic plates; iii) a complete comparison sample of 26 galaxies of all morphological types down to m_R = 16.05 (or m_B \\simeq 17.5), also ...
A Digital X-ray imaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS method): A simple ...
The Soldier Information Requirements Technology Demonstration (SIREQ TD) project is an experimentation program to identify technologies that significantly enhance the performance of our future soldiers. One of the study series involved a 2 x 2 factorial comparison of the benefits of digital maps over paper maps, and the use of radios vs. no radios. Thirty-two Canadian regular force infantry soldiers performed force-on-force tactical assault missions in wooded terrain, with each soldier participating in all four test conditions. The radios were configured to operate in 4 subnets: 1 channel for each of the 2 Assault Groups (4 soldiers on a channel); a Section Commander/2IC channel; and an all-users channel. Note that in the no-radio conditions soldiers still operated the press-to-talk switch to allow recording of communications, but the speaker volume was set to zero. All communications were date/time stamped, identified as to the user and channel, and the audio was ...
The aim of this study was to assess the possibility of digital image analysis of pit-and-fissure discoloration in order to diagnose caries. Digital images showing pit-and-fissure discoloration in 100...Full Text Available
Tutorial on digital libraries. Site also contains links to other reference materials on digital libraries as well as links to courses on the subject. Keywords: Information Systems - Information Systems Applications, Information Storage and Retrieval, Database Management, multimedia
Objective: The paper describes and evaluates the use of Clinical Digital Libraries Project (CDLP) digital library collections in terms of their facilitation of timely clinical information...Full Text Available
A form for the clinical evaluation of bovine digital disease was developed. In this article, each section of the resulting Digit Evaluation Form is discussed and justified. By following the...Full Text Available
The digital AVR must have the level of redundancy and control functions that conform to the configuration of the excitation control system and to the importance of a particular generator for the user. The digital AVR is not simply a digital version of the analog AVR, but can realize sophisticated control functions that were difficult to achieve with analog circuits, thus making it possible to enhance the stability of power system by PSS (power system stabilizer). This paper describes the test results of the digital AVRs applied to power plants, their system configuration and functions, as well as the outline of an auto-tuning PSS or AT-PSS planned to be incorporated in the digital AVR in the future.
In the past, the need for high quality images, i.e., very sharp and clear images, in mammography have prevented mammography equipment from being digitalized; however, recent advances in detection technology such as development of a high resolution digital X-ray detector have produced improvements in digital mammography. Digital mammography is expected to replace conventional film-screen mammography. We have developed a digital mammography system, named ''SEPIO NUANCE DT'', which is equipped with a direct conversion flat panel detector. The present paper describes the high basic performance and user-friendly functions of the system. (author)
Objective:This paper describes the Lamar Soutter Library's process and costs associated with digitizing 300 doctoral dissertations for a newly implemented institutional repository...Full Text Available
A technique for quantitative determination of cephalothin and desacetylcephalothin in serum using a method based on high-pressure liquid chromatography is described. Both compounds were quantitatively...Full Text Available
This paper discusses the stationary neutron radiography system (SNRS) with respect to the component positioning systems (CPSs) and the rationale behind their design. As design work is on-going at Science Applications International Corporation, this report gives a current update of progress. The SNRS has four separate radiography bays, Bays 1 through 4. The first three bays have automated positioning systems for real-time and near real-time neutron radiography of aircraft components. Bay 4 has been designed to accommodate components from the solid rocket booster, but will be used first for film radiography of pyrotechnic components.
Digital libraries continue to flourish. At the same time, the principles of user-centered design and the practice of usability testing have been growing in popularity, spreading their influence into the library sphere. This article explores the confluence of these two trends by surveying the current literature on usability studies of digital libraries. This article focuses on the methodology of studies of multimedia digital libraries. (Contains 1 table and 45 notes.)
In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).
In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).
SummaryThis paper evaluates the status of digitization in 30 Nigerian university libraries with a view to identifying the status, progress, prospects and challenges to digitize library materials and form the basis of providing a roadmap to successful execution of digitization projects. The study assessed the status of digitization of past question papers, theses and dissertations in Nigerian university libraries from May to September 2006 through a self-administered questionnaire, site visits and interviews. It was found that, though there are automation services in those universities, there is no digitization of these materials mentioned in the surveyed institutions. The major obstacles militating against digitizing in the university libraries include lack of funds, lack of appropriate fa...
Purpose - The purpose of this paper is to describe the processes and procedures utilized by Jacksonville State University's Houston Cole Library to digitize an oral history collection and provide access to it through the Library's catalog, web presence, and the state-wide digital repository initiative, Alabama Mosaic (see www.alabamamosaic.org). Design/methodology/approach - The paper is based on the Library's experiences in acquiring, digitizing, creating metadata for and making accessible a collection of oral histories. Findings - The paper describes the obstacles overcome, issues encountered, procedures established, and ramifications of the project. Practical implications - Many institutions are currently digitizing unique collections as part of repository initiatives, both institutiona...
Surgical resection is the only curative treatment strategy for intrahepatic cholangiocarcinoma (CC). Therefore, accurate staging is essential for appropriate management of patients with CC. We assessed the usefulness of 2-["1"8F]fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) in the staging of CC. We undertook a retrospective review of FDG PET images in 21 patients (10 female, 11 male; mean age 57 years) diagnosed with CC. Ten patients had hilar CC and 11, peripheral CC. Patients underwent abdominal magnetic resonance imaging (MRI) (n=20) and computed tomography (CT) (n=12) for the evaluation of primary tumours, and chest radiography and whole-body bone scintigraphy for work-up of distant metastases. For semi-quantitative analysis, the maximum voxel standardised uptake value (SUV_m_a_x) was obtained from the primary tumour. All peripheral CCs showed intensely increased FDG uptake, and some demonstrated ring-shaped uptake ...
Industrial radiography accounts for approximately half of all the reported accidents for the nuclear related industry, in both developed and developing countries. This Safety Report is the result of a review made of a large selection of accidents in industrial radiography reported by regulatory authorities, professional associations and scientific journals. A small, representative selection of 43 accident descriptions has been used to illustrate the primary causes of radiography accidents, and a set of measures provided to prevent the recurrence of such accidents or to mitigate the consequences of those that do occur. These accident descriptions were categorized by primary causes as follows: inadequate regulatory control; failure to follow operational procedures; inadequate training; inadequate maintenance; human error; equipment malfunction or defect; design flaws; and wilful violation. The information in this Safety ...
This paper describes an electronic imaging system for producing real time neutron radiography from a low power research reactor, which will allow inspections of samples with high efficiency, in terms of measuring time and result analysis. This system has been implanted because of its potential use in various scientific and industrial areas where neutron radiography with photographic film could not be applied. This real time system is installed in neutron radiography facility of Argonauta nuclear research reactor, at the Instituto de Engenharia Nuclear of the Comissao Nacional de Energia Nuclear, in Brazil. It is adequate to perform real time neutron radiography of static and dynamic events of samples.
This paper describes an electronic imaging system for producing real time neutron radiography from a low power research reactor, which will allow inspections of samples with high efficiency, in terms of measuring time and result analysis. This system has been implanted because of its potential use in various scientific and industrial areas where neutron radiography with photographic film could not be applied. This real time system is installed in neutron radiography facility of Argonauta nuclear research reactor, at the Instituto de Engenharia Nuclear of the Comissao Nacional de Energia Nuclear, in Brazil. It is adequate to perform real time neutron radiography of static and dynamic events of samples.
In Niigata University Hospital, most of conventional radiography were changed to Fuji computed Radiography (FCR) from July 1988. To evaluate its clinical utility, questionnaires relating to FCR image were distributed to all physicians including non-radiologists in the hospital after three months. The ratio of the physicians evaluated FCR image to be better than conventional image was 75% in chest radiography, 64% in abdominal radiography. FCR tomography of bone, joint, cranium and chest was also evaluated to be better than conventional by most of the physicians. Reduced size of the film and difficulty in detecting interstitial shadows of the lung were mentioned to be the fault of FCR. (author).
In Niigata University Hospital, most of conventional radiography were changed to Fuji computed Radiography (FCR) from July 1988. To evaluate its clinical utility, questionnaires relating to FCR image were distributed to all physicians including non-radiologists in the hospital after three months. The ratio of the physicians evaluated FCR image to be better than conventional image was 75% in chest radiography, 64% in abdominal radiography. FCR tomography of bone, joint, cranium and chest was also evaluated to be better than conventional by most of the physicians. Reduced size of the film and difficulty in detecting interstitial shadows of the lung were mentioned to be the fault of FCR. (author).
The usefulness and clinical applicability of computed radiography(FCR) in X-ray examination of the stomach were evaluated in comparison with film-screen (FS) radiography by both phantom experiments and clinical studies. Receiver operating characteristic (ROC) curve analysis consisting of 25 normal and 25 artificially created simulated lesions on an orginally created Styrofoam phantom showed no difference in lesion detectability between FCR and FS radiography. Both were also equal in evaluation of the internal structure and margin of the 25 lesions by visual ranking. ROC curve analysis of clinical cases was performed in 30 cases, 20 normal and 10 abnormal, while evaluation by visual ranking was performed on 18 lesions. There was no significant difference between FCR and FS radiography either with ROC curve analysis or visual ranking, although the variations were somewhat greater in the clinical cases ...
The usefulness and clinical applicability of computed radiography(FCR) in X-ray examination of the stomach were evaluated in comparison with film-screen (FS) radiography by both phantom experiments and clinical studies. Receiver operating characteristic (ROC) curve analysis consisting of 25 normal and 25 artificially created simulated lesions on an orginally created Styrofoam phantom showed no difference in lesion detectability between FCR and FS radiography. Both were also equal in evaluation of the internal structure and margin of the 25 lesions by visual ranking. ROC curve analysis of clinical cases was performed in 30 cases, 20 normal and 10 abnormal, while evaluation by visual ranking was performed on 18 lesions. There was no significant difference between FCR and FS radiography either with ROC curve analysis or visual ranking, although the variations were somewhat greater in the clinical cases ...
WELLOG is a system of programs developed at the Earth Science Laboratory to be used to digitize well logs and perform some analysis and plotting of the data. Multiple logs can be plotted side by side for correlation analysis and up to three logs can be plotted in a cross plot. Data entry and editing functions are also provided by the programs. This system of well log interpretation programs is presently operating on the University of Utah UNIVAC 1108 computer. Digitizing of well logs is accomplished by an old model CALMA (off-line) digitizer. Those parts of WELLOG that handle the digitized data tapes are extremely machine dependent. The parts of WELLOG that produce the plots and handle the data beyond the digitized data tape are more portable.
Low resolution visual polarimetric photographic imagery of the Galveston Bay oil spill from a tanker accident on July 28, 1990 was obtained and analyzed. The low resolution imagery (30 to 100 meters) was obtained concurrently with high resolution (1 meter), and is representative of what would be seen by a polarimetric satellite. Orthogonal red-green-blue (RGB) polarimetric images obtained with color photography were digitized by KODALUX on to a CD ROM. These polarimetric images were then used to calculate the percent polarization. The positive and negative percent polarized radiation scattered by each of the sea surface waves is seen individually in high resolution imagery. (Percent polarization is defined as positive when the dominant radiation is perpendicular to the plane of incidence and negative when it is parallel). The analysis of low resolution polarimetry is approached in a different manner than high resolution; in high resolution, individual waves are ...
The use and application of remote sensing data for monitoring the environmental impacts of open cast lignite mining in Eastern Germany is described. This investigation is based on the digital analysis of several Landsat-TM and ERS-1 data sets acquired from 1989 to 1994. The characteristics of the imagery enable quantitative analysis of different open cast mine features, such as waste, water bodies, change of land use, reclamation processes and estimation of vegetation cover in the affected areas. On the basis of the Maximum Likelihood Classification of Landsat Thematic Mapper (TM) data the open cast mining areas were separated into bare open cast areas and areas of less and dense vegetation. The bare open cast areas were classified with respect to type of different sediments and the vegetation was seperated into different classes according to the age of the vegetation and the density cover. Apart from these, water bodies within the mining areas ...
In Japan, the development of next-generation Light Water Reactor has been launched since April 2008. The development program will be completed in 2015. The purpose of development is to cope with the replacement for existing nuclear power plants after 2030 in Japan and the expanding demand for nuclear power in the world; 'Nuclear Renaissance.' The reactor also aims to be global standard at around 2030. The requirements for global standard and domestic users have been investigated through the feasibility study of past 2 years, 2006-2007, and six innovative features or 'Core-Concepts' were established as follows. A) Reactor core system with uranium enrichment above 5% for significant decrease of spent fuel discharge and prominent higher availability B) Long-life materials and innovative water chemistry technologies for 80 years plant lifetime and significant reduction of occupational dose C) Seismic isolation technologies to standardize plant design independent from site conditions D) ...
Described herein are the results of the FY1994 research program for analysis and evaluation for thin film solar cells. The study on quantitative analysis of hydrogen atoms in a plasma determines quantity of hydrogen atoms in the plasma of monosilane diluted with hydrogen. It is found, contrary to expectation, that quantity of hydrogen atoms in the plasma decreases as it is more diluted with hydrogen. The study on light-induced degradation of the thin chlorine-base amorphous silicon films confirms that the plasma CVD method with 20% of dichlorosilane gas added to monosilane gas produces the thin amorphous silicon film 3 times faster than the conventional method. The thin film has essentially the same defect density as the one prepared by the conventional method, showing good photoelectric characteristics. The thin film of chlorinated amorphous silicon has a 1 digit lower defect density than the conventional one of amorphous silicon, as revealed ...
Purpose/Objective: At present, treatment verification between portal and reference images is performed based on manually-identified features by radiation oncologist, which is both time-consuming and potentially error-prone. There is a demand for the computerized verification procedure in clinical application. The purpose of this study is to develop a computerized portal verification scheme for pelvic treatment fields. Materials/Methods: The automated verification system involves image acquisition, image feature extraction, feature matching between reference and portal images and quantitative evaluation of patient setup. Electronic portal images with a matrix size of 256 x 256 and 12 bit gray levels were acquired using a liquid matrix electronic portal imaging device. Simulation images were acquired by digitizing simulation films using a TV camera into images with 256 x 256 matrix and 8 bit gray levels. Initially a Canny edge detector is applied ...
BackgroundThe purpose of our investigation was to compare a digital templating system to conventional templating techniques when preoperatively planning for total hip arthroplasty.MethodsWe...Full Text Available
The use of digital wound images would allow remote consultation between patients, physicians, or other caregivers over the Internet. To evaluate the efficacy and validity of digital images for assessment...Full Text Available
In summer 2000, the Cushing/Whitney Medical Library at Yale University began a demonstration project to digitize classic articles in neurosurgery from the late 1800s and early 1900s. The objective of...Full Text Available
This study used a PCR-based approach targeting 16S rRNA gene fragments to determine the occurrence and association of the three bovine digital dermatitis (BDD) treponeme phylogroups within lesions found...Full Text Available
Several efforts have been made to completely automate cephalometric analysis by automatic landmark search. However, accuracy obtained was worse than manual identification in every study. The analogue-to-digital...Full Text Available
Several widely recognized sources of nomenclature regarding the bovine external digit were reviewed, compared, and utilized in a clinical survey of bovine digital disease. During this process, some...Full Text Available
BackgroundThis in vitro study was conducted to compare the accuracy of two digital image receptors in identifying the location of tip of a fine endodontic file and radiographic apex...Full Text Available
Neutron radiography and neutron radioscopy are rapidly becoming the valuable tools for nondestructive testing and basic research. The Phoenix Memorial Laboratory has developed a neutron facility capable of both film neutron radiography and real time neutron radioscopy, and has used this facility to study several phenomena of interest to the researchers in many areas. Neutrons can be used for imaging the phenomena that X-ray cannot image, such as the presence, absence or movement of hydrogenous materials inside metals such as aluminum or steel. There are three basic methods for obtaining images using neutrons: high resolution film neutron radiography, real-time neutron radioscopy and transfer film neutron radiography. The neutron radiography facility at Phoenix Memorial Laboratory, the neutron radioscopic imaging systems, the neutron radiographic detectors, lubrication studies, spray ...
sharing data and computational resources, and accessing information in digital libraries." Bill Wulf (1989) In a Collaboratory, the presentation/meeting concept embodied...
... program incorporates the proven concepts of advanced distributed learning, modeling and simulation, and electronic digital libraries (Figure 1) to ...
The Digital Raster Graphic (DRG) is a raster image of a scanned USGS topographic map including the collar information, georeferenced to the UTM grid....
Radiology departments often underestimate the importance of protecting medical data during transmission, including the precautions taken to ensure data protection. In teleradiology, transmitted as well as stored patient data have to be signed digitally according to the currently valid regulation (Roentgenverordnung, RoeV). The DICOM standard facilitates a digital signature. So far, medical image manufacturers only announced to support this security feature. We introduce a solution that extends the feature of digital signing to older modalities. (orig.)
02.10.10 - NASA and Texas Instruments are using the theme of human space exploration to develop digital libraries of math and science problems for high ...
The McMaster Neutron Radiography Facility (MNRF) is fortunate to own the only Real-Time Neutron Radiography system in Canada. Current research at the MNRF involves the visualization of gas-liquid and gas-solid two-phase flow in complex channels, such as nuclear fuel channels, using light water, heavy water, freon-134A, slurries, and other fluids. Other research at the MNRF has examined single-phase flow, material purity, film deposition, turbine blades, and automotive parts.
In the Wajima lung cancer screening program conducted under the auspices of Kanazawa University Hospital, Fuji Computed Radiography (FCR) was utilized in a new chest radiography trial. The results of the screening program are that the necessity of repeat examinations due to poor image quality are less common and the method enables detection of small pulmonary nodular shadows which are possibly candidates for surgery. Oblique chest X-ray with FCR is remarkably effective for the detection and the identification of small lesions. However, the disadvantage of slow processing and high cost must be fully satisfied if FCR is to become a new imaging modality for mass screening.
In the Wajima lung cancer screening program conducted under the auspices of Kanazawa University Hospital, Fuji Computed Radiography (FCR) was utilized in a new chest radiography trial. The results of the screening program are that the necessity of repeat examinations due to poor image quality are less common and the method enables detection of small pulmonary nodular shadows which are possibly candidates for surgery. Oblique chest X-ray with FCR is remarkably effective for the detection and the identification of small lesions. However, the disadvantage of slow processing and high cost must be fully satisfied if FCR is to become a new imaging modality for mass screening. (author).
Chest radiograms obtained by using Fuji Computed Radiography (FCR) system were compared to conventional film/screen radiograms. The FCR images showed better image quality in diagnostic information than the conventional chest images. In FCR, the radiation exposure to patient for chest examination could be reduced up to one tenths of conventional chest examination. The main advantages or FCR were considered to depend on the contrast processing and frequency processing properties. The use of FCR in clinical work may improve both diagnostic quality and radiation exposure.
A diagnosis of the refrigerant flows in a refrigerator was carried out by real-time neutron radiography. The thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute and the real-time image processing system developed by Musashi Institute of Technology were used. Freon evaporating flows in the evaporator, condensing flows in the condenser, flashing flows in the capillary tube and flows in the accumulator were visualized and the dynamic behaviors under practical conditions were clarified. In the case of the capillary tube of 0.8 mm i.d., a cooled-CCD camera was utilized. (orig.).
An important goal for digital libraries is to enable researchers to more easily explore related work. While citation data is often used as an indicator of relatedness, in this paper we demonstrate that digital access records (e.g. http-server logs) can be used as indicators as well. In particular, we show that measures based on co-access provide better coverage than co-citation, that they are available much sooner, and that they are more accurate for recent papers.
The paper represents the result of research in the field of digital libraries functionalities in the context of new Grid infrastructure support. It is defined a new vector of knowledge society, informational vector - content vector. It presents a Grid European project which includes Romanian partners, and it defines on this base a digital library model which can be applied for the libraries in Romania.
A real-time two-dimensional void fraction distribution measurement of gas-liquid two-phase flow was carried out by real-time neutron radiography and real-time image processing. The JRR-3M real-time thermal neutron radiography system and a Musashi dynamic image processing system were used. Image processing methods to calculate two-dimensional and cross-sectional void fraction distributions were proposed. The void fraction distribution was calculated by non-linear processing of the neutron radiography image and displayed by pseudo-color in real-time. A simple gas-liquid two-phase flow induced by injecting gas through needles at the bottom of water pool in a rectangular vessel was tested. (orig.).
For the application of dynamic neutron radiography to the two-phase flow research using HANARO, several experimental items to which the radiography technique is beneficial were identified through the review of the outputs from the related researches and the discussions with experts. Also, the investigation of the equipments including the beam port, camera and converter was made and a hardware and a software for image processing were equipped. It was confirmed that the calibration curve for the attenuation of neutron beam in fluid which is required for the two-phase flow experiment could be obtained by the computer code calculation. Based on the investigation results on the equipment and the results from the measurement of BNCT beam characteristics, a high speed camera and an image intensifier will be purchased. Then, the high speed dynamic neutron radiography facility for two-phase flow experiments will be fully equipped.
Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor
Thermal hydraulics of a liquid metal is important to design the blanket of a magnetic confined fusion reactor. Since a liquid metal has high thermal and electrical conductivity, the flow characteristics are often different from those of an ordinary liquid like water especially in thermal convection and under a magnetic field. It is difficult to simulate such flows in a liquid metal cooled blanket by water. Flow visualization is a popular method to study thermal hydraulics. Since most of metals are visible by neutron rays, neutron radiography is available to the flow visualization of a liquid metal. The purpose of this study is to develop a visualization technique of the flow in a liquid metal by real-time neutron radiography using the tracer and the dye injection methods. A real-time thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute was used for the visualization test.
Thermal hydraulics of a liquid metal is important to design the blanket of a magnetic confined fusion reactor. Since a liquid metal has high thermal and electrical conductivity, the flow characteristics are often different from those of an ordinary liquid like water especially in thermal convection and under a magnetic field. It is difficult to simulate such flows in a liquid metal cooled blanket by water. Flow visualization is a popular method to study thermal hydraulics. Since most of metals are visible by neutron rays, neutron radiography is available to the flow visualization of a liquid metal. The purpose of this study is to develop a visualization technique of the flow in a liquid metal by real-time neutron radiography using the tracer and the dye injection methods. A real-time thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute was used for the visualization test.
Fuji Computed Radiography (FCR) was evaluated for detection of intracardiac calcification as compared with conventional radiography in 77 patients. Intracardiac calcification was found in 37 patients (left coronary artery: 31, right coronary artery: 11, valve: 9) on cine-fluorography. The sensitivity for detecting these calcified foci with FCR was higher than conventional screen-film method. Especially, sensitivity for detecting left coronary artery calcification with FCR was significantly higher than conventional method (71 %, 32 %) (p < 0.01), Fine anatomical details of calcification were well shown on FCR. Chest radiography using FCR is of great use for detection of intracardiac calcification. (author).
The evaluation of biological markers is recognized as necessary to the future of toxicology, epidemiology, and quantitative risk assessment. For biological markers to become widely accepted, their validity...Full Text Available
Quantitative microscopy has been extensively used in biomedical research and has provided significant insights into structure and dynamics at the cell and tissue level. The entire procedure...Full Text Available
The incidence of columnar cell lesions in breast core needle biopsies since full-field digital mammography in comparison with screen-filmed mammography was analyzed. As tiny microcalcifications characterize columnar cell lesions at mammography, we hypothesized that more columnar cell lesions are diagnosed since full-field digital mammography due to its higher sensitivity for microcalcifications. In all, 3437 breast core needle biopsies performed in three hospitals and resulting from in total 55?159 mammographies were revised: 1424 taken in the screen-filmed mammography and 2013 in the full-field digital mammography period. Between the screen-filmed mammography and full-field digital mammography periods, we compared the proportion of mammographies that led to core needle biopsies, the...
The study was performed for evaluating the risk effect of digital systems on the total plant. Based on risk monitor, a fault tree model for the Korean Standard Nuclear Power Plants (KSNPP), we integrate the fault-tree models for Digital Plant Protection System (DPPS) and Digital Engineered SaFety Actuation System (DESFAS) which are the most important safety-critical I and C systems in the KSNPP. In this study, however, three important factors (the probabilities of manual actuation failure, the software failure probability, and the watchdog timer fault coverage) are treated as the variables of the sensitivity study because quantification methodologies for these factors are not developed yet. Not only the unavailability of digital safety-critical system itself, but also the risk effect of digital systems on the total plant should be assessed to prove the safety of ...
This work describes a combinatorial model for estimating the reliability of the embedded digital system by means of multi-state function. This model includes a coverage model for fault-handling techniques implemented in digital systems. The fault-handling techniques make it difficult for many types of components in digital system to be treated as binary state, good or bad. The multi-state function provides a complete analysis of multi-state systems as which the digital systems can be regarded. Through adaptation of software operational profile flow to multi-state function, the HW/SW interaction is also considered for estimation of the reliability of digital system. Using this model, we evaluate the reliability of one board controller in a digital system, Interposing Logic System (ILS), which is installed in YGN nuclear power units 3 and 4. Since the proposed ...
The Linac Coherent Light Source (LCLS) is required to deliver a high quality electron beam for producing coherent X-rays. As a result, high resolution beam position monitoring is required. The Beam Position Monitor (BPM) digitizer acquires analog signals from the beam line and digitizes them to obtain beam position data. Although Matlab is currently being used to test the BPM digitizer?s functions and capability, the Controls Department at SLAC prefers to use Experimental Physics and Industrial Control Systems (EPICS). This paper discusses the transition of providing similar as well as enhanced functionalities, than those offered by Matlab, to test the digitizer. Altogether, the improved test stand development system can perform mathematical and statistical calculations with the waveform signals acquired from the digitizer and compute the fast Fourier transform (FFT) of the signals. ...
A series of real-time, neutron radiography, experiments are ongoing at the Texas A and M Nuclear Science Center Reactor (NSCR). These tests determine the resolving capabilities for radiographic imaging of two phase water and air flow regimes through small diameter flow channels. Though both film and video radiographic imaging is available, the real-time video imaging was selected to capture the dynamic flow patterns with results that continue to improve. (author)
The characteristics of real-time neutron radiography are described briefly in this paper, and the acquirement of neutron flux, the selection of convertor and the structure of the twilight imaging system and the image-sampling and image-processing system in SPRR-300 reactor are also analyzed detailedly. The experimental result of real-time neutron radiograph is too analyzed in this paper
The image processing system for the dynamic neutron radiography has been developed. It is based on the hardware subset, composed by the method of the pipe-line and use of algorithm of local statistics. The processing speed per one pixel is shorter than 100 n sec and video-rate processing can be executed on it. Some image processes for improving the quality of the real-time neutron image, noise reduction and contrast stretching would be attempted by the use of this system. (author).
An analyzer-based X-ray phase-contrast imaging (ABI) setup has been mounted at the Brazilian Synchrotron Light Laboratory (LNLS) for multiple imaging radiography (MIR) purposes. The algorithm employed for treating the MIR data collected at LNLS is described, and its reliability in extracting the distinct types of contrast that can be obtained with MIR is demonstrated by analyzing a test sample (thin polyamide wire). As a practical application, the possibility of studying ophthalmic tissues, corneal sequestra in this case, via MIR is investigated.
The study compares the doses absorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations.
The diagnostic value of the portable chest radiography obtained with Fuji computed radiography (FCR) was evaluated in comparison with conventional images in 23 patients who were admitted to ICU in Yokohama City University Hospital. On the whole , FCR produced more exellent images than conventional screen-film radiographs. Especially the evaluation for the demonstration of the catheters, the endotracheal tubes and the tracheal shadows obtained high score. We discuss the clinically utility of FCR for the portable chest radiographs in ICU. (author).
The diagnostic value of the portable chest radiography obtained with Fuji computed radiography (FCR) was evaluated in comparison with conventional images in 23 patients who were admitted to ICU in Yokohama City University Hospital. On the whole , FCR produced more exellent images than conventional screen-film radiographs. Especially the evaluation for the demonstration of the catheters, the endotracheal tubes and the tracheal shadows obtained high score. We discuss the clinically utility of FCR for the portable chest radiographs in ICU. (author).
Controls of welds by radiographies are an efficient non destructive technique but it can be dangerous if not managed following a strict set of rules. EDF acts to avoid risks via several ways (adapted tools, best practices) and seeks for an integration of the radiographies with respect to the other maintenance operations, in order to raise the ratio of availability of the electricity production unit. This study explores an original analysis of industrial radiography: the influence of the representations of the workplace and its utilizations. This document supports the utilization of some space constraints as explanations of difficulties in the industrial radiography activity. The document proposes innovative points of view coming for on-site observations and from a theoretical background 'cognitive sciences' completed by technical propositions. (author)
In neutron radiography, as in other forms of NDE, it is sometimes desirable to observe dynamic events. This need has generated increased interest in the development of real-time neutron radiography systems and neutron-to-light converter screens optimized for real-time application. Two screens currently available at MURR are: (1) a 0.041-cm-thick Gd_2O_2S screen manufactured by 3M Company and (2) a "6KiF-ZnS(Ag) screen (NE 426) manufactured by Nuclear Enterprises. These screens are presently used in conventional film neutron radiography and represent two of the commercially available screens that have demonstrated the greatest resolution and sensitivity. Unfortunately, these screens have severe limitations when used for real-time neutron radiography. In order to isolate and minimize the factors contributing to these limitations, several neutron absorbers and phosphorus were studied at MURR. The screen ...
Neutron radiography has been put to practical use in foreign countries as one of nondestructive inspection technologies, but in Japan, its application to other scientific fields is mainly researched. The reason is, the neutron radiography apparatuses installed in Japan are hard to be industrially utilized for a number of reasons, but also the characteristics of neutron radiography are not clearly established, and it is not standardized. The part from a collimator through an object to a detector is called ``upstream``, the part of an image detector is called ``midstream``, and the part of image processing is called ``downstream``. The nonparallel property of beam, image distortion and the lack of sharpness, beam quality and the interaction of neutron beam with an object are discussed about the upstream. The intensity of neutron beam, the energy spectra, the effective total macroscopic cross section, the effective energy, the ...
A previous paper introduced the use of wave digital filters as a basic building block for power system simulation, particularly suitable for real-time applications. This paper stresses the simulation of non-linear and switching elements, emphasizing the advantages of the wave filters implementation. The digital structure is maintained even when non-linear components change their characteristics or power electronic devices switch their states. As a very important by-product, the suppression of numerical oscillations related to the trapezoidal rule is achieved in a rather simple way, with no effects on simulation results.
An algorithm for pose and motion estimation using corresponding features in images and a digital terrain map is proposed. Using a Digital Terrain (or Digital Elevation) Map (DTM/DEM) as a global reference enables recovering the absolute position and orientation of the camera. In order to do this, the DTM is used to formulate a constraint between corresponding features in two consecutive frames. The utilization of data is shown to improve the robustness and accuracy of the inertial navigation algorithm. Extended Kalman filter was used to combine results of inertial navigation algorithm and proposed vision-based navigation algorithm. The feasibility of this algorithms is established through numerical simulations.
and Vendors on the Web Bartleby.com "Great books online." Electronic Texts & Digital Libraries Links to the full text of books and other texts on the Web. Law and Politics...
Purpose - This paper aims to discuss the procedures and methods developed at Washington State University to digitize and make accessible historic moving images. Design/methodology/approach - The paper describes the selection and the use of low-cost technologies to transfer analog film to digital formats. Issues related to the conversion, description, and online hosting of digital films are also addressed. Findings - Though the steps involved in digitizing film are not trivial, the benefits of access both for the public and archives staff outweigh the expense and labor involved. The procedures described in this paper involve low upfront costs and are sustained through cost recovery fees. Research limitations/implications - The focus of this paper is on managing, describing, and providing on...
of the digital hearing aid technology that led to the cochlear implant. Former. Marshall Space Flight Center engineers. John Richardson and Joseph Howard ...
Apr 9, 2003 ... Adam Kissiah Jr., a retired KSC engineer, will be honored for his development of the digital hearing aid technology that led to the cochlear ...
evaluation, novelty detection, resource discovery, interfaces and visualization, digital libraries, computational social science, and cross-lingual information retrieval. The CIIR...
The refrigerant two-phase flows in a capillary tube and a distributor used in a compression-type refrigerator were visualized by real-time neutron radiography. The thermal neutron radiography system of JRR-3M at the Japan Atomic Energy Research Institute was used. In the visualization experiments of the two-phase flow in the capillary tube of 2 mm I.D., a cooled CCD camera was used, and the axial one-dimensional distributions of void fraction were measured. For the distributor, a high sensitivity video camera with a silicone intensified target tube was used. From the visualized images, the refrigerant behaviors in the distributor were clearly shown, and the liquid fraction in each tube was measured. As a result, it was shown that the refrigerant behaviors in the distributor effected the distributing performance of the refrigerant flow.
An explanation is given of what a loop heat pipe (LHP) is, and how it works. It is then shown that neutron imaging (both real time neutron radioscopy and single exposure neutron radiography) is an effective experimental tool for the study of LHPs. Specifically, neutron imaging has helped to identify and correct a cooling water distribution problem in the condenser, and has enabled visualization of two-phase flow (liquid and vapor) in various components of the LHP. In addition, partial wick dry-out, a phenomenon of great importance in the effective operation of LHPs, is potentially identifiable with neutron imaging. It is anticipated that neutron radioscopy and radiography will greatly contribute to our understanding of LHP operation, and will lead to improvement of LHP modeling and design. PMID:15246420
An explanation is given of what a loop heat pipe (LHP) is, and how it works. It is then shown that neutron imaging (both real time neutron radioscopy and single exposure neutron radiography) is an effective experimental tool for the study of LHPs. Specifically, neutron imaging has helped to identify and correct a cooling water distribution problem in the condenser, and has enabled visualization of two-phase flow (liquid and vapor) in various components of the LHP. In addition, partial wick dry-out, a phenomenon of great importance in the effective operation of LHPs, is potentially identifiable with neutron imaging. It is anticipated that neutron radioscopy and radiography will greatly contribute to our understanding of LHP operation, and will lead to improvement of LHP modeling and design.
An explanation is given of what a loop heat pipe (LHP) is, and how it works. It is then shown that neutron imaging (both real time neutron radioscopy and single exposure neutron radiography) is an effective experimental tool for the study of LHPs. Specifically, neutron imaging has helped to identify and correct a cooling water distribution problem in the condenser, and has enabled visualization of two-phase flow (liquid and vapor) in various components of the LHP. In addition, partial wick dry-out, a phenomenon of great importance in the effective operation of LHPs, has been identified with neutron imaging. It is anticipated that neutron radioscopy and radiography will greatly contribute to our understanding of LHP operation, and will lead to improvement of LHP modeling and design.
Real-time neutron radiography (RTNR) is now proving to be a valuable research tool in the study of hydrogenous fluid flow. One of the most significant advantages of neutron radiography is the ability to image hydrogenous substances (such as lubricants, coolants, and fuels) inside metallic materials such as aluminum and titanium engines. By using RTNR, one can then study dynamic events such as the movement of liquids inside these solids. The Phoenix Memorial Laboratory (PML) at the University of Michigan has recently developed and installed a facility dedicated to RTNR. The work at PML has shown that RTNR of dynamic events can provide information enabling the researcher to follow dynamic events that were previously impossible or impractical. This paper will show the variety of uses of RTNR presently being pursued at PML.
Real-time neutron radiography (RTNR) is now proving to be a valuable research tool in the study of hydrogenous fluid flow. One of the most significant advantages of neutron radiography is the ability to image hydrogenous substances (such as lubricants, coolants, and fuels) inside metallic materials such as aluminum and titanium engines. By using RTNR, one can then study dynamic events such as the movement of liquids inside these solids. The Phoenix Memorial Laboratory (PML) at the University of Michigan has recently developed and installed a facility dedicated to RTNR. The work at PML has shown that RTNR of dynamic events can provide information enabling the researcher to follow dynamic events that were previously impossible or impractical. This paper will show the variety of uses of RTNR presently being pursued at PML.
For neutron radiography (NR), photographic techniques have been mainly used for many years. To observe a dynamic event and to test many samples, the real-time neutron radiography (i.e. neutron television - NTV) system has been introduced at the E-2 experimental tube of the Kyoto University Research Reactor (KUR). The NTV system has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuel, to investigation of moving objects and to neutron computed tomography (NCT). New approaches using some advanced neutron converters, a high sensitive and resolution TV camera and a high performance image processing system are being undertaken for standard indicators, visualization on air-water two-phase flow, NCT and so on. (author).
The use of nondestructive evaluation (NDE) methods is proposed for characterization of transuranic (TRU) waste stored at the Radioactive Waste Management Complex. These NDE methods include real-time x-ray radiography, real-time neutron radiography, x-ray and neutron computed tomography, thermal imaging, container weighing, visual examination, and acoustic measurements. An integrated NDE system is proposed for characterization and certification of TRU waste destined for eventual shipment to the Waste Isolation Pilot Plant in New Mexico. Methods for automating both the classification waste and control of a complete nondestructive evaluation/nondestructive assay system are presented. Feasibility testing of the different NDE methods, including real-time x-ray radiography, and development of automated waste classification techniques are covered as part of a five year effort designed to yield a production waste characterization ...
Experimental investigations have been conducted to determine two-phase natural circulation interfacial parameters by real-time neutron radiography. The natural circulation loop used in the present experiments consists of a vertical two-phase section, a gas liquid separator, and a gas injection/heating section. Experiments were performed in a neutron beam for visualization using realtime neutron radiography system. The natural circulation was initiated by injection of known gas flow rate in the heated section. Two-phase flow interfacial parameters including interfacial geometry and phase velocities etc. for bubbly flow and slug flow patterns observed in the experiments will be given in detail. The results indicate that while the natural circulation is largely as expected and that steady stable flows are possible, there are some local phenomena that introduce instabilities due to the interfacial phenomena between the liquid and the gas.
Experimental investigations have been conducted to determine two-phase natural circulation interfacial parameters by real-time neutron radiography. The natural circulation loop used in the present experiments consists of a vertical two-phase section, a gas liquid separator, and a gas injection/heating section. Experiments were performed in a neutron beam for visualization using realtime neutron radiography system. The natural circulation was initiated by injection of known gas flow rate in the heated section. Two-phase flow interfacial parameters including interfacial geometry and phase velocities etc. for bubbly flow and slug flow patterns observed in the experiments will be given in detail. The results indicate that while the natural circulation is largely as expected and that steady stable flows are possible, there are some local phenomena that introduce instabilities due to the interfacial phenomena between the liquid and the gas.
Concerning the transient phenomenon of solid-gas two-phase flow, an attempt was made to visualize and measure a flow phenomenon in which three-dimensional bubbles occurred, grew and collapsed in the vicinity of a gas injection nozzle while solid particles were circulating. Such a phenomenon could not or hardly be visualized and measured by conventional methods. Such two-phase flow was visualized using neutron radiography, its characteristics measured and the usefulness of the visualization by neutron radiography confirmed. For this purpose, three-dimensional fluidized bed vessels, rectangular or cylindrical-shaped, made of steel or aluminum sheet, were prepared. Polyethylene or glass beads were used as solid particles and activated carbon particles as the tracer. In the experiment, nitrogen gas was blown into the vessel from one nozzle and distributors provided at the bottom of the vessel and exhausted from the top via the exhaust valve, by ...
This paper describes radiography as one of the most efficient and cost effective methods for inspecting electric cabls. Details of one project in particular, i.e., the inspection of high-pressure, oil-filled, pipe-type cables (HPOF) are given. 2 refs.
In the design of LWRs, the forecast of critical heat flux (CHF) is important. The existing CHF correlation equations include the arbitrary constants based on experimental data, therefore, their range of application is limited. For advancing the research and development of high conversion LWRs or passive safety reactors, the development of more general CHF forecasting technique has been demanded. In order to elucidate the mechanism of CHF occurrence and construct the general forecasting model based on physical phenomena, the detailed observation of flow phenomena near a heat generation surface is indispensable. The experiment of observing boiling two-phase flow and CHF phenomena by applying neutron radiography technique was carried out. The utilization of neutron radiography in the field of heat-transferring flow is explained. The experimental setup and the experimental method, the experimental conditions, and the results of the observations of ...
A technique was developed that permits fluid flow to be visualized even where the flow is completely shrouded by metal. The technique employs real-time neutron radiography, which is similar to x-ray radiography except a collimated beam of neutrons is used. Various combinations of neutron-opaque tracer materials were tested with neutron-transparent fluid. Neutron opaque tracers, such as solid particles, fluid droplets, and streaklines were imaged through metal walls as they convected in neutron-transparent ambient fluid. Visualization of bubbles/voids were evaluated for possible future applications. Surface-flow patterns were also imaged by using neutron-opaque tufts. These techniques were evaluated for image contrast, resolution, and the ability to accurately track fluid flow fields. The techniques were also modeled to optimize contrast in various flow configurations. Imaging techniques such as real-time video, high speed video, and ...
A technique was developed that permits fluid flow to be visualized even where the flow is completely shrouded by metal. The technique employs real-time neutron radiography, which is similar to x-ray radiography except a collimated beam of neutrons is used. Various combinations of neutron-opaque tracer materials were tested with neutron-transparent fluid. Neutron opaque tracers, such as solid particles, fluid droplets, and streaklines were imaged through metal walls as they convected in neutron-transparent ambient fluid. Visualization of bubbles/voids were evaluated for possible future applications. Surface-flow patterns were also imaged by using neutron-opaque tufts. These techniques were evaluated for image contrast, resolution, and the ability to accurately track fluid flow fields. The techniques were also modeled to optimize contrast in various flow configurations. Imaging techniques such as real-time video, high speed video, and ...
New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey meter. The results obtained were as follows: 1) By using FCR system the radiation ...
New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey meter. The results obtained were as follows: 1) By using FCR system the radiation ...
Selective alveolo-bronchography (SAB) has been routinely used to evaluate anatomical changes in the bronchiole and its distal air spaces. A narrowing of the bronchiole and abnormal pooling of contrast medium in the destroyed air space are the prime findings. Since the object of radiography is extremely thin, direct magnification radiography is mandatory to obtain radiologic details. However, the problem with this technique is that radiographic quality varies depending upon the size of the patient and the concentration of contrast medium to be introduced in the lung. This study had two goals. One was to improve the image quality of SAB by Fuji Computed Radiography (FCR). FCR provides radiographs with a good contrast and stable density throughout a wide range of exposure factors which occur in the use of SAB. The other goal was to separately evaluate morphological abnormalities in the outer and inner zones of the lung using ...
A demonstration of the first mobile 'on-off' neutron radiography system, developed by Vought Corporation Advanced Technology Center, has been conducted at McClellan Air Force Base. On-site neutron radiography operations with the engineering model were carried out to demonstrate the potential of such a system for in situ detection of hidden moisture and corrosion in aircraft structures, and to assess the performance of the unique hardware system in a depot environment. Inspections were performed on F-111 and F-106 aircraft, and several structures removed from T-39 and A-10 aircraft were also inspected. The effectiveness of the new N-ray system for imaging moisture and corrosion was confirmed after subsequent removal of skins from some of the F-111 structures. Excellent correlation of radiographic images with actual moisture and corrosion damage was attained. Both film and real time/near real time neutron imaging were ...
In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in the retrocardiac and subdiaphragmatic regions, respectively. ...
To assess the diagnostic capability Fuji computed radiography (FCR) using a dual side reading system was compared to the conventional radiography using a film-screen system. Twenty-eight patients with lung cancer were examined with a new FCR system (FCR 5501D) and a conventional screen-film system concurrently. FCR utilizes a reading system that detects emissions from dual sides of imaging plate. Chest X-rays were obtained with same exposure factors in both systems. Image qualities of both systems were compared by two radiologists using a five-level score. There were no lesion that FCR images were inferior to film-screen images. The frequency of score +1 or +2 that FCR images were superior to film-screen images was 31% in large nodular shadows, 40% in accompanying shadows with a nodule, 67% of small nodular shadows, and 43% of the lymph node swelling in the hilum of the lung or mediastinum. In large nodular shadows which were the most frequent ...
In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in the retrocardiac and subdiaphragmatic regions, respectively. ...
Characteristics relevant to cardiovascular disease, including anthropometry, arterial blood pressure, serum cholesterol levels, chest radiography and electrocardiography, were investigated in a survey...Full Text Available
The study of the dynamics of lubricants and mechanical components encased in metal enclosures is important to many industries. Of particular importance is the flow characteristics of oils or similar lubricants within the metal enclosure during operation of the device. The purpose of this summary is to report on the design and successful application of a real-time neutron radiography system to study the lubrication and design of the piston and seal of a gas spring. In addition, the application of this technique to a wider range of similar problems using the pulse capability of the TRIGA reactor is described.
The study of the dynamics of lubricants and mechanical components encased in metal enclosures is important to many industries. Of particular importance is the flow characteristics of oils or similar lubricants within the metal enclosure during operation of the device. The purpose of this summary is to report on the design and successful application of a real-time neutron radiography system to study the lubrication and design of the piston and seal of a gas spring. In addition, the application of this technique to a wider range of similar problems using the pulse capability of the TRIGA reactor is described.
The paper presents information in the form of data, tables and diagrams compiled to a broad but very up-to-date survey of required radiation for the various most frequently performed X-ray examinations of patients. The required dose is discussed from the point of view of radiation protection, defining the inevitably administered dose to the skin, the frequency of examinations, and the diagnostic image quality as the main three factors to be observed, as these determine the radiation dose to the patient and to the personnel. The somatic risks of radiography examinations are a point of main interest. (DG).
Real-time neutron radiography (RTNR) is rapidly becoming a valuable tool for nondestructive testing and basic research with a wide variety of applications. The Phoenix Memorial Laboratory (PML) at the University of Michigan has developed an RTNR facility and has been using this facility to study several phenomena of interest to researchers in many areas. These phenomena include imaging of the internal fluid flow in gas turbine engine nozzles and coking and debris deposition in several gas turbine nozzles. This paper presents a summary of the technique and facilities involved in these applications.
A neutron collimator system is being designed as part of a neutron imaging facility for computed tomography and real-time neutron radiography research at the through beam port of the University of Texas TRIGA reactor. Lack of sufficient information about collimator systems in a through port from the literature necessitated the use of Monte Carlo calculations using the MCNP code 3 to search for optimal design configuration and materials that maximize the thermal neutron intensity at the image plane while minimizing the fast neutrons and gamma radiation.
Visualizations by real-time neutron radiography are demonstrated of various flow patterns of nitrogen gas-water two-phase flow in a stainless-steel tube, water inverted annular flow in a stainless-steel tube, flashing flow in an aluminium nozzle and fluidized bed in aluminium tube and vessels. Photographs every 1/60 s are presented by an image processing method to show the dynamic behaviours of the various flow patterns. It is shown that this visualization method can be applied efficiently to multiphase flow researches and will be applicable to multiphase flows in industrial machines. (author).
Visualizations by real-time neutron radiography are demonstrated of various flow patterns of nitrogen gas-water two-phase flow in a stainless-steel tube, water inverted annular flow in a stainless-steel tube, flashing flow in an aluminium nozzle and fluidized bed in aluminium tube and vessels. Photographs every 1/60 s are presented by an image processing method to show the dynamic behaviours of the various flow patterns. It is shown that this visualization method can be applied efficiently to multiphase flow researches and will be applicable to multiphase flows in industrial machines. (author).
Widespread use of audio in computer-based training (CBT) occurred with the advent of the interactive videodisc technology. This paper discusses the alternative of digital audio, which, unlike videodisc audio, enables one to rapidly revise the audio used in the CBT and which may be used in nonvideo CBT applications as well. We also discuss techniques used in audio script writing, editing, and production. Results from evaluations indicate a high degree of user satisfaction. 4 refs.
This document contains papers which were presented at the First ACM International Conference on Digital Libraries. Topics processed for this document included information retrieval and index structures for structured documents. Individual papers have been processed separately for the United States Department of Energy databases.
Breast cancer represents today more than 30% of all cancers and is responsible for about 20% of deaths due to cancer. The potentialities of mammography have increased in recent years through improvements in equipment and methodologies. In this paper the conventional mammography using film and image intensifiers is compared with digital mammography. Digital mammography presents clear advantages in storage and handling of information. Also its higher sensitivity will lead to an earlier detection of anomalies and a decrease in the number of invasive exams and surgeries
From nuclear science symposium; San Francisco, California, USA (14 Nov 1973). A digital Fourier analyzer was programmed to perform reactor neutron noise analysis measurements and on-line processing of the data to obtain the steady-state reactivity. The system is suitable for recovering cross spectral density with low correlatedsignal component and for repetitive measurements with efficient use of reactor time. (auth)
Stabilization of the particle beam position with respect to the focusing optics in the third generation synchrotron light sources is crucial to achieving low emittance and high brightness. For this purpose, global and local beam orbit correction feedbacks will be implemented in the APS storage ring. In this article, the authors discuss application of digital signal processing to particle/photon beam position feedback using the PID (proportional, integral, and derivative) control algorithm.
Digital optical processing (DOP) was conceived to encompass the advantages of both electronic and optical processors, which are parallelism, flexibility, and high accuracy. The authors discuss the concept of parallelism, how it applies to DOP differently than to electronic parallel processing, and other potential advantages in using DOP. A PLZT memory device is described which can perform a series of logic or memory operations. From several of these PLZT devices a DOP is constructed to illustrate some of its programmability features.
We present an approach to automatically generate interfaces supporting personalized interaction with digital libraries; these interfaces augment the user-DL dialog by empowering the user to (optionally) supply out-of-turn information during an interaction, flatten or restructure the dialog, and enquire about dialog options. Interfaces generated using this approach for CITIDEL are described.
The design characteristic of the autocontrol technique of the combined centrifuge is introduced. Digital technique, vary structure control and interface technique, graphical display techniques, digital communication technique as well as electronic technique are applied in the course of research. Automation in the operation of large scale combined centrifuges and the course of combined test has been realized and it can coordinate with other systems of status monitoring, data collecting and centrifugal force-aerodynamic force matched load automatically
A new era for the field of Galactic structure is about to be opened with the advent of wide-area digital sky surveys. In this article, the author reviews the status and prospects for research for 3 new ground-based surveys: the Sloan Digital Sky Survey (SDSS), the Deep Near-Infrared Survey of the Southern Sky (DENIS) and the Two Micron AU Sky Survey (2MASS). These surveys will permit detailed studies of Galactic structure and stellar populations in the Galaxy with unprecedented detail. Extracting the information, however, will be challenging.
The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (I.D.: 4.08 mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification of the images taken by the neutron radiography, the scattered ...
The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (inner diameter; 4.08mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3 M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification of the images taken by the neutron radiography, the ...
The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (I.D.: 4.08 mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification of the images taken by the neutron radiography, the scattered ...
OBJECTIVETo assess the new quantitative bone scan parameters as markers of Charcot neuroosteoarthropathy (CNO) activity.RESEARCH DESIGN AND METHODSForty-two...Full Text Available
Emphasis was put on the comparative quantitative structure-activity approaches to the exploration of action mechanisms of structurally different classes of compounds showing the same type of activity...Full Text Available
Effective small interfering RNA (siRNA)–mediated therapeutics require the siRNA to be delivered into the cellular RNA-induced silencing complex (RISC). Quantitative information of this essential...Full Text Available
A single radial hemolysis test was developed for quantitation of specific antibody to non-hemagglutinating viruses. With the human coronaviruses as models, this test utilizes the binding properties...Full Text Available
We have exploited ``progeny testing'' to map quantitative trait loci (QTL) underlying the genetic variation of milk production in a selected dairy cattle population. A total of 1,518 sires, with progeny...Full Text Available
Gene expression data has been used in lieu of phenotype in both classical and quantitative genetic settings. These two disciplines have separate approaches to measuring and interpreting epistasis, which...Full Text Available
Deficits in prepulse inhibition (PPI) are a biological marker for schizophrenia. To unravel the mechanisms that control PPI, we performed quantitative trait loci (QTL) analysis on 1,010 F2 mice derived...Full Text Available
The Electronic REference To access In vivo Concentrations (ERETIC) method was applied to 1H HR-MAS spectroscopy. The accuracy, precision, and stability of ERETIC as a quantitative...Full Text Available
In this paper we argue that the set of wireless, mobile devices (e.g., portable telephones, tablet PCs, GPS navigators, media players) commonly used by human users enables the construction of what we term a digital ecosystem, i.e., an ecosystem constructed out of so-called digital organisms (see below), that can foster the development of novel distributed services. In this context, a human user equipped with his/her own mobile devices, can be though of as a digital organism (DO), a subsystem characterized by a set of peculiar features and resources it can offer to the rest of the ecosystem for use from its peer DOs. The internal organization of the DO must address issues of management of its own resources, including power consumption. Inside the DO and among DOs, peer-to-peer interaction mechanisms can be conveniently deployed to favor resource sharing and data dissemination. Throughout this paper, we show that most of the ...
The field of digital libraries (DLs) coalesced in 1994: the first digital library conferences were held that year, awareness of the World Wide Web was accelerating, and the National Science Foundation awarded $24 Million (U.S.) for the Digital Library Initiative (DLI). In this paper we examine the state of the DL domain after a decade of activity by applying social network analysis to the co-authorship network of the past ACM, IEEE, and joint ACM/IEEE digital library conferences. We base our analysis on a common binary undirectional network model to represent the co-authorship network, and from it we extract several established network measures. We also introduce a weighted directional network model to represent the co-authorship network, for which we define $AuthorRank$ as an indicator of the impact of an individual author in the network. The results are validated against conference program committee ...
Digital libraries play a crucial role in distance learning. Nowadays, they are one of the fundamental information sources for the students enrolled in this learning system. These libraries contain huge amount of instructional data (text, audio and video) offered by the distance learning program. Organization of the digital libraries is therefore very important for easy and fast access to the desired information. Improper categorization of data may mislead the students searching the library. Since manual categorization of huge amount of data might be challenging, an automatic and reliable method is needed. In this sense, this paper proposes an automated categorization scheme for digital libraries in distance learning. The categorization scheme is designed and developed by a pattern recognition approach. Effectiveness of the proposed scheme is evaluated on widely used Reuters database. The results of the ...
The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.
Over three years ago, the Core Integration team of the National Science Digital Library (NSDL) implemented a digital library based on metadata aggregation using Dublin Core and OAI-PMH. The initial expectation was that such low-barrier technologies would be relatively easy to automate and administer. While this architectural choice permitted rapid deployment of a production NSDL, our three years of experience have contradicted our original expectations of easy automation and low people cost. We have learned that alleged "low-barrier" standards are often harder to deploy than expected. In this paper we report on this experience and comment on the general cost, the functionality, and the ultimate effectiveness of this architecture.
Landscapes are both a synthesis and an expression of national, regional and local cultural heritages. It is therefore very important to develop techniques aimed at cataloguing and archiving their forms. This paper discusses the LDL (Landscape Digital Library) project, a Web accessible database that can present the landscapes of a territory with documentary evidence in a new format and from a new perspective. The method was tested in a case study area of the river Po valley (Northern Italy). The LDL is based on a collection of photographs taken following a systematic grid of survey points identified through topographic cartography; the camera level is that of the human eye. This methodology leads to an innovative landscape archive that differs from surveys carried out through aerial photographs or campaigns aimed at selecting "relevant" points of interest. Further developments and possible uses of the LDL are also discussed.
The field of a digital-image processing has experienced dramatic growth and increasingly widespread applicability in recent years. Fortunately, advances in computer technology have kept pace with the rapid growth in volume of image data in these and other applications. Digital image processing has become economical in many fields of research and in industrial and military applications. While each application has requirements unique from the others, all are concerned with faster, cheaper, more accurate, and more extensive computation. The trend is toward real-time and interactive operations, where the user of the system obtains preliminary results within a short enough time that the next decision can be made by the human processor without loss of concentration on the task at hand. An example of this is the obtaining of two-dimensional (2-D) computer-aided tomography (CAT) images. A medical decision might be made while the patient is still under ...
Explicitly defining virtual collections in a digital library can benefit both users and contributors. This paper outlines the costs and benefits for defining virtual collections and describes an implementation of collection-level metadata in two digital libraries. Our work suggests that component repositories of NSDL would profit by describing their collection, and sub-collections, using a schema such as the one we implemented. This would enable NSDL to provide a rich, cross-linked hierarchy of virtual collections. By sharing collection-level, rather than item-level, metadata, collections would provide detailed resource information, presumably keeping most of their viewership, while NSDL would provide a broad description of resources.
Digital topographic models are the foundation of more advanced modeling applications and ultimately inform planning and decision making in many fields. Despite this, the error associated with these models and derived attributes is commonly overlooked. Little attention has been given in the scientific literature to the benefits gained from having less error in a model or to the corresponding cost associated with reducing model error by choosing one product over another. To address these gaps in knowledge we evaluated the error associated with five digital elevation models (DEMs) and derived attributes of slope and aspect relative to the same attributes derived from LiDAR data. We also estimated the acquisition and processing costs per square kilometer of the five test models and the LiDAR m...
Purpose - The purpose of this paper is to encourage other libraries to provide access to their own original content via the web. By way of case study, the process of identifying materials, scanning them and creating web access to original content will be explored. Design/methodology/approach - To implement a book digitization project, three major things need to be present. The library must own material that was published prior to 1923, making them safely out of copyright in the USA; the library needs access to server space on the web and the library needs to own scanning equipment. Findings - This project demonstrated that a library does not necessarily need to obtain grant funding to begin an effective and successful digitization program. It also revealed a few things that would improve t...
Conventional radiography has been the accepted nondestructive testing (NDT) method used for many years to either ''accent'' or ''reject'' a field weld in the pipeline industry. However, conventional radiography requires the expense of film, developing chemicals, and manpower for film development. It also normally has a delay of 2 hours or more between when the weld was radiographed and when the radiographic film of the weld is available for interpretation. Over the last few years, a newer approach to performing radiographic testing, called ''realtime'' radiography, has been used in several different types of field inspection operations. The realtime radiography system forms the image with optical imaging in lieu of photographic film. Objectives of this project were: (Task 1) Integration of ...
In this two chapter report, instrumentation used to collect seismic data is described. This data acquisition system has two parts: (1) portable anolog seismic recorders and related ``hand-held-testers`` (HHT) and (2) portable digitizing units. During the anolog recording process, ground motion is sensed by a 2-Hz vertical-component seismometer. The voltage output from the seismometer is split without amplification and sent to three parallel amplifier circuit boards. Each circuit board amplifiers the seismic signal in three stages and then frequency modulates the signal. Amplification at the last two stages can be set by the user. An internal precision clock signal is also frequency modulated. The three data carrier frequencies, the clock carrier frequency, and a tape-speed compensation carrier frequency are summed and recorded on a recorded on a cassette tape. During the digitizing process, the cassette tapes are played back and the signals are ...
Apr 20, 2009 ... "YY" is the 2-digit filter identifier .... In our example you can see a point- like optical/UV source in each of the filters at the ... The "sigma" paramter gives the detection threshold in terms of Gaussian sigma. ...
Destress blasting is commonly used as a stress control technique at the Galena Mine, Wallace, Idaho, where the U.S. Bureau of Mines maintains a cooperative research program with the mine operators (ASARCO). A digital seismic array and an array of borehole...
In addition, for breast cancer, a fifth field, Reconstruction--First Course is recorded. V.02.E Reconstruction--First Course (breast only) 1 digit These codes for these fields are included as Appendix C of this manual.
Digital information flow within the intensive care unit (ICU) continues to grow, with advances in technology and computational biology. Recent developments in the integration and archiving of these...Full Text Available
This article reviews briefly a range of the latest monitoring and controlling equipment for use in coal mines. This includes pressure transmitters, shale/coal discriminator, nucleonic bunker level indicator, automatic steering and monitoring system, oscilloscope/multimeter, and microprocessor based digital display controllers. 1 fig.
Purpose: The present research aims to identify the difficulties and obstacles for developing digital libraries in the seven regional branches of Islamic Azad University (IAU), Iran, and to study the status of librarians' skills and education programmes at these institutions. Design/methodology/approach: The 40 individuals working in the regional branch libraries of IAU were surveyed by a questionnaire consisting of 34 questions, and the collected data were analysed using SPSS software (version 16). Findings: It was found that the most important difficulties are the lack of suitable equipment and untrained personnel (i.e. a lack of sufficient training programmes). Research limitations/implications: Because of the small number of participants, it is suggested that a larger scale study is carried out. It is also proposed that the suggestions made by the participants will be considered and implemented, based on the digital library (DL) developments ...
Abstract: Data currently available in the Ontario Timber Inventory include Canada ... Download 1:250 000 scale Ontario Timber Inventory data in Arc Export ...
This flyover of the Hawaiian island of Oahu was made by draping Jan. 13, 2010, image data from the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) instrument on NASA's Terra spacecraft over new ASTER Version 2 digital elevation data.
BackgroundMany three-dimensional (3D) images are routinely collected in biomedical research and a number of digital atlases with associated anatomical and other information have...Full Text Available
The behavior of a small power system consisting of two interconnected generators is simulated in real-time by a prototype Digital Transient Network Analyzer (TNA). The prototype Digital TNA consists of two Computational Modules and one I/O Module. The Modules communicate with each other through ribbon cables. Each Computational Module simulates one Turbo-Generator, its Transformer, its Governor, Exciter, and Power System Stabilizer Systems. The numerical integration is shared by two TMS320C30 DSPs at a step-size of 100 microseconds in real-time. The I/O module post-processes the state variables and presents selected information for analog display. The paper presents oscillograms from a test program which includes symmetry checks and behavioral checks against well known waveforms of hunting oscillations, synchronization out-of-phase torques, and subsynchronous resonance phenomena. The success of the Digital TNA depends on: ...
This paper describes Image Engine, an object-oriented, microcomputer-based, multimedia database designed to facilitate the storage and retrieval of digitized biomedical still images, video, and text...Full Text Available
This talk sketches out the main parameters (technology, circuit design) that have an influence on the hardening of digital CMOS integrated circuits. For each technology the more common defects are mentioned. General design rules are proposed to prevent or limit those defects. (D.L.). 2 refs., 2 figs.
Ever-changing audio technology requires that National Library Service NLS always be aware of developments and prepare carefully for any systematic changes that may be desired or required. Usefulness, cost effectiveness, thoughtful stewardship, and educate...
We describe a decision support system to distinguish among hematology cases directly from microscopic specimens. The system uses an image database containing digitized specimens from normal...Full Text Available
1. Digital imaging and photometry were used in conjunction with the fluorescent Ca2+ indicator, Fura-2, to examine intracellular Ca2+ signals produced by depolarization of single adrenal chromaffin...Full Text Available
A new method for removing periodic background patterns from pictures is presented. The basic spatial frequency composition of the pattern is determined from an estimate of the power spectrum of the picture. A digital restoration filter is then created from a modified version of the power spectrum. The method is extremely effective and can be automated.
Acceptance testing of mammographic imaging systems technical is the first approach in order to guarantee that mammograms will be achieved with the minimum radiation dose compatible with an image quality suitable for diagnose purposes. The aim of this study is to assess the practical applicability of different protocols in acceptance test of digital mammographic systems. This study has been carried out on the results of the acceptance tests of five flat panel digital mammographic systems. Parameters established in the systems technical specifications and those evaluated in the consulted protocols were tested. Due to the fact that the legislation in our country does not demand to consider a specific protocol, the results obtained were also compared considering different existing protocols. Results show discrepancies between manufacturers limiting values and those established in the protocols. Some parameters, such as the automatic exposure ...
A high-speed fiber-based network for the transmission and display of digitized full-motion cardiac images has been developed. Based on Asynchronous Transfer Mode (ATM), the network is scaleable, meaning...Full Text Available
When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated through contrast manipulation to be equal to that obtained by grid use. ...
When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated through contrast manipulation to be equal to that obtained by grid use. Further, optimal ...
A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is considered to be one of the routine examinations, in view of low exposure doses. The need of conventional ...
A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is considered to be one of the routine examinations, in view of low exposure doses. The need of conventional ...
A LIXI (Light Intensifier X-ray Image) device has been employed in a real-time neutron radiography system. The LIXI is coupled to a video camera and the real-time images can be observed in a TV monitor, and processed in a computer. In order to get the real-time system operational, the neutron radiography facility installed at the IEA-R1 m nuclear research reactor of the IPEN-CNEN/S P has been optimized. The most important improvements were the neutron/gamma ratio, the effective energy of the neutron beam, decrease of the scattered radiation at the irradiation position, and the additional shielding of the video camera. Several one-frame as well as computer processed images are presented. The overall Modulation Transfer Function for the real-time system was obtained from the resolution parameter p = 0:44 +- 0:04 mm; the system sensitivity, evaluated for a Perspex step wedge, was determined and the average value is 0:70 +- 0:09 mm. (author)
This paper shows the efficacy of computed radiography for major airway in pediatrics. For this purpose, we examined 40 children (range 2 weeks to 14 years; mean 2.3 years) using Fuji Computed Radiography (FCR) and radiation dose using pediatric phantom under FCR and conventional film and screen system. In comparison study with FCR and conventional film and screen system, FCR images are superior to conventional system in all cases. Scorings were done for the quality of the image of the pharynx, the trachea, and both main bronchi. In phantom study to check radiation dose, radiation dose could be reduced 1/6 of the value using high speed film and screen and 1/15 of the value using conventional speed film and screen. FCR also showed clear airway images in all cases but technical failure to evaluate the clinical lesion. These results suggest that FCR is the adequate imaging modality to evaluate the major airway in children. (author).
Since the PWR plants in Japan have been operated more than 30 years, main instrumentation control equipment of analog systems has been renewed to digital control systems. Renewal works had to be done in short period within periodical inspection term and for several facilities. The Mitsubishi LTD group had been provided with these market needs by its digital control system (MELTAC-NplusR 3) applicable to main instrumentation control equipment for primary and secondary systems and had already finished the renewal for practical plants. (T. Tanaka)
Information glut is one of the primary characteristics of the electronic age. Managing such large volumes of information (e.g., keeping track of the types, where they are, their relationships, who controls them, etc.) can be done efficiently with an intelligent, user-oriented information management system. The purpose of this paper is to describe a concept for managing information resources based on an intelligent information technology system developed by the Argonne National Laboratory for managing digital libraries. The Argonne system, Intelligent Query (IQ), enables users to query digital libraries and view the holdings that match the query from different perspectives.
The design of High-Voltage, Direct-Current transmission cables insulated with oil-impregnated cellulose paper is constrained by the maximum temperature and the maximum steady-state and transient stresses (voltage gradients) that the cable insulation can reliably withstand over the desired operating lifetime. Because the electrical stresses in the insulation are related in a very complex fashion to temperature, applied voltage and cable geometry, iterative techniques are required to compute the values of these stresses. Digital computers are ideally suited for these iterative techniques. This paper presents the principal equations and logic needed to develop suitable computer programs.
A typical incident response pits technicians against networks that aren't prepared forensically. [1, 2] If practitioners do consider collecting network forensic data, they face a choice between expending extraordinary effort (time and money) collecting forensically sound data, or simply restoring the network as quickly as possible. In this context, the concept of organizational network forensic readiness has emerged. This paper proposes a methodology for "operationalizing" organizational network forensic readiness. The methodology, and the theoretical analysis that led to its development, are offered as a conceptual framework for thinking about more efficient, proactive approaches to digital forensics on networks.
A register transfer language is used to present the basic concepts of computer hardware architecture. Material needed for understanding computer organisation, design, and programming is included. The various functional units of digital computers (central processor, microprogram control; arithmetic algorithms; input-output; and memory organisation), are examined. A basic computer is developed to demonstrate the components of computer hardware and software architecture. Parallel processing and multiprocessor systems are discussed. Numerous MSI and LSI digital functions are introduced with explanations of their characteristics. Cache memory and the hardware requirements for a memory management unit are covered.
Use of a broadband Local Area Network (LAN) for transmission of classified and secure unclassified information requires monitoring capabilities which are sensitive to discrete segments of the network frequency spectrum. A viable monitoring system must be capable of detecting possible intrusion attempts or network malfunctions and alerting operating and security personnel. This report documents the results of an evaluation of the Magnavox CATV Systems Inc. Digital System Sentry software for network monitoring. Recommendations are made on its possible future role in broadband LAN security monitoring throughout the Nuclear Weapons Complex.
Energy and angular double-differential cross-section (DDX) data of fragment production reactions by neutrons or protons are very scarce due to experimental difficulties of fragment detection. We adopted a Bragg curve spectrometer (BCS), which is a gridded-ionization chamber that can identify fragments on the basis of the Bragg peak value. We have been developing the BCS for neutron and proton-induced reactions applying the digital waveform analysis technique to obtain better ability of particle discrimination than the analog electronic circuit. (T. Tanaka)
Real-time neutron radiography has been used to study the dynamic behavior of two-phase flow and measure vapor fractions in a steam-water duct at atmospheric pressure. This unique experimental technique offers one the opportunity to observe and record on videotape now Patterns and transient behavior of two-phase flow inside opaque containers without perturbing the environment. The neutron radiographic technique is non-intrusive and requires no special transparent window region. Data are recorded simultaneously over a large area of interest. Image processing of the video data can be employed to measure bubble velocities and time-averaged and Instantaneous vapor fractions.
Twenty patients with lesions in the trachea or bronchus underwent energy subtraction Fuji computed radiography (FCR). Images obtained were compared with those from conventional FCR (plain FCR). ''Very clear'' images (in which the contour of the trachea and bronchus could be clearly defined) were obtained in 12/22 (55 %) by energy subtraction FCR and in 3/22 (14 %) by plain FCR; ''clear'' images (in which the contour could be defined) in 9/22 (41 %) by energy subtraction FCR and in 18/22 (82 %) by plain FCR; and ''unclear'' images (in which the contour could not be defined) in 1/22 (5 %) by both methods. Energy subtraction FCR, as well as plain FCR, yielded high image quality for the trachea. Energy subtraction FCR was superior to plain films when tumors existed within the trachea. (Namekawa, K.).
The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).
The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).
Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy electron beam therapy. (author)
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed at the University of Texas TRIGA reactor. Extensive Monte Carlo design calculations were used to determine optimal design parameters of the neutron collimator system to avoid costly trial and error. Thermal neutron flux determined by gold foil activation is 5 {times} 10{sup 6} n/cm{sup 2}{center_dot}s at the primary imaging location with beam size of 22.5 cm in diameter. The collimation ratio can be varied from 125 to 235. The neutron-to-gamma ratio is 7.8 {times} 10{sup 6} n/cm{sup 2}{center_dot}mR. The facility has been tested for radiography and tomography applications and is now fully operational.
A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.
An all solid-state kicker pulser for a proton radiography system has been designed. Multiple solid-state modulators stacked in an inductive-adder configuration are utilized in this kicker pulser design. Each modulator is comprised of multiple metal-oxide-semiconductor field-effect transistors (MOSFETs) which quickly switch the energy storage capacitors across a magnetic induction core. Metglas is used as the core material to minimize loss. Voltage from each modulator is inductively added by a voltage summing stalk. A circuit model of a prototype inductive adder kicker pulser modulator has been developed to predict the performance of the pulser modulator. The modeling results are compared with experimental data.
Consultant and advanced practice are relatively new concepts in radiography. There is evidence to show that as the career progression framework is being adopted the numbers of consultant and advanced practitioners in radiography are growing with the latter growing at a faster rate. The article considers the concept of advanced and consultant practice and the education requirements to support development. Preparation for an advanced practice role begins at the practitioner stage. Masters' level programmes are available to support the development of advanced practice. Education needs to be flexible as new advanced practice roles emerge. It is necessary to take practitioners beyond a defined modality to include leadership and people skills. These are essential for those aspiring to become consultants. Consultants require a high level of clinical knowledge for expert practice but also strategic vision and interpersonal intelligence to ...
Neutron radiography systems are being used for real-time visualization of the dynamic behavior as well as time-averaged measurements of spatial vapor fraction distributions for two phase fluids. The data in the form of video images are typically recorded on videotape at 30 frames per second. Image analysis of he video pictures is used to extract time-dependent or time-averaged data. The determination of the average vapor fraction requires averaging of the logarithm of time-dependent intensity measurements of the neutron beam (gray scale distribution of the image) that passes through the fluid. This could be significantly different than averaging the intensity of the transmitted beam and then taking the logarithm of that term. This difference is termed the dynamic error (error in the time-averaged vapor fractions due to the inherent time-dependence of the measured data) and is separate from the static error (statistical sampling uncertainty). Detailed analyses of ...
Twenty one examinations of chest FCR were performed in 15 malignancies with pulmonary metastases. The rate for demonstrating, less than 5, from 5 to 15, and more than 15 mm pulmonary nodules using with FCR was retrospectively evaluated on the basis of the lesions detected with CT. The demonstrating rate for pulmonary nodules less than 5 mm in diameter was only 8 % ; for 5 - 15 mm nodules, about 87 %. However, several 5 - 15 mm nodules were not demonstrated due to overlap of the pulmonary vessels and bony structures. All nodules more than 15 mm were demonstrable. Chest FCR may demonstrate more pulmonary nodules than conventional radiography. However, the further studies should be required for the improvement of detectability of them with FCR. (author).
Intra-arterial subtraction angiography(IADSA) using Fuji computed radiography(FCR) was performed on 130 patients with cervical, pelvic, peripheral and abdominal diseases. It was compared with conventional angiography(radiographs produced by combining photographic film with an intensifying screen) performed on same patients. Radiographs produced by FCR were better than conventional radiographs in cervical, pelvic and peripheral angiography. In the abdominal angiography using FCR, there was misregistration artifact in some cases, but in hepatic angiography, the new radiographs under the injection of small amount of contrast medium(about 10ml) and the short exposure duration(about 10 seconds) were excellent. It was as valuable as conventional angiography (infusion hepatic angiography) for diagnosing hepatic neoplasms. (author).
A Real-Time Neutron Radiography (RTNR) system is developed to determine two-phase flow parameters for a vertical co-current two-phase flow channel with a hexagonal finned bundle. Image processing techniques are applied to visualize the two-phase flow, and procedures for measuring flow regime, cross-sectional averaged void fraction, time averaged void fraction, and void distribution for this complex geometry are discussed. The results show that the experimental flow regime map agrees well with an existing flow regime model for a hexagonal fined bundle. The hexagonal finned bundle is observed to significantly affect the void fraction, void migration, and void fluctuation along the axial flow channel.
A number of diagnostic X-ray units in Poland were subjected to analysis. The air kerma on X-ray tables was measured for the X-ray parameters used routinely during lumbo-sacral spine radiography of standard adult patient. Measurements of air kerma were performed using TLD made of lithium-fluoride. The doses received by patients in different X-ray departments can differ more than two orders of magnitude (from 0.42 mGy up to 72.11 mGy), for the same X-ray examination. The dose can be significantly reduced if fluorescent screens made from components of rare earth are used. (author). 10 refs, 1 fig., 2 tabs.
AFFF has fabricated the (U, Pu)O_2 mixed oxide fuels for PHWRs, BWRs, PFBRs and FBTRs. The quantitative dissolution of the fuel samples are required within time for accurate determination of uranium-plutonium in chemical quality control laboratory. This paper describes the use of microwave heating technique in quantitative dissolution of (U, Pu)O_2 MOX (from 0.4% to 44% PuO_2). (author)
... These assumptions are quantitatively investigated by calculating tie icldti\\e inportance of ... A modified lon-shore current model is used to study the ...
BackgroundDiscrepancies between the conclusions of different meta-analyses (quantitative syntheses of systematic reviews) are often ascribed to methodological differences. The objective...Full Text Available
A specific application of single photon emission tomography to the relative quantitation of the pituitary region is described together with the results obtained in 19 patients with pituitary adenoma...Full Text Available
Motivation: Automatic recognition of cell identities is critical for quantitative measurement, targeting and manipulation of cells of model animals at single-cell resolution. It has been...Full Text Available
Typing Workshop": [Introductions] [Intro, DNA Basics, and Historical Perspective] [DNA Extraction] [Validation and QA/QC] [DNA Quantitation] [PCR Amplification] [STR Loci and Kits]...
BACKGROUND: An approach to the study of the pharmacokinetics of drugs in the lung is to measure their concentrations in bronchial biopsy specimens. The main criticism of this technique is that bronchial...Full Text Available
This laboratory exercise demonstrates some basic principles in parasitology by using experimental studies of the relationship of Hymenolepis diminuta with its rodent host.
Abstract: The current financial crisis has now led most major central banks to rely on quantitative easing. The unique Japanese experience of quantitative easing is the only experience which enables us to judge this therapy's effectiveness and the timing of the exit strategy. In this paper, we provide a new empirical framework to examine the effectiveness of Japanese monetary policy during the ''lost'' decade and quantify the effect of quantitative easing on Japan's activity and prices. We combine advantages of Markov-switching VAR methodology with those of factor analysis to establish two major findings. First, we show that the decisive change in regime occurred in two steps: it crept out from late 1995 and established itself durably in February 1999. Second, we show for the first time th...
Absolute measurements of cerebral blood flow (CBF) are an important endpoint in studies of cerebral pathophysiology. Currently no accepted method exists for in vivo longitudinal...Full Text Available
... and high-quality photospheric-phase Type II SN spectra to constrain core- collapse SN explosions, massive star evolution, and distances in the Universe ...
OBJECTIVEEvaluate the qualitative and quantitative differences between moderated and unmoderated on-line social support groups focused on asthma.DESIGNA...Full Text Available
Computer-Aided Prediction of Chemical Ecotoxicity on the basis of Quantitative Structure-Activity Relationships with the Use of Physico-Chemical Descriptors, Including H-bond Parameters
AIM: To investigate the effects of gallbladder stones on motor functions of the gallbladder and the dynamics of bile flow in asymptomatic gallstone disease.METHODS: Quantitative hepatobiliary...Full Text Available
BackgroundSeveral fractal and non-fractal parameters have been considered for the quantitative assessment of the vascular architecture, using a variety of test specimens and of computational...Full Text Available
OBJECTIVE AND DESIGNThis study used qualitative and quantitative methods to examine the reasons primary care physicians and nurses offered for their inability to initiate guideline-concordant...Full Text Available
The concentration of apolipoproteins was measured by quantitative immunoelectrophoresis in rat serum, in the lipoprotein-free ultracentrifugal fraction (density greater than 1.21) of serum, and in renal...Full Text Available
In this model, without dark matter, the flat rotation curves of galaxies and the mass-to-light ratios of clusters of galaxies are described quantitatively. The hypothesis is that the agent of gravitational...Full Text Available
From the numbers of radiographs of the different examinations and the total amount of radiological diagnostics in the GDR their possible modification by new imaging techniques is discussed under the aspects of costs and radiation burden. Film-screen-systems are of special importance, because they also will be most frequently used image recording system in future. The importance of their various properties and parameters, methods of determining these parameters as well as future developments are analyzed from the standpoint of practical requirements.
From the numbers of radiographs of the different examinations and the total amount of radiological diagnostics in the GDR their possible modification by new imaging techniques is discussed under the aspects of costs and radiation burden. Film-screen-systems are of special importance, because they also will be most frequently used image recording system in future. The importance of their various properties and parameters, methods of determining these parameters as well as future developments are analyzed from the standpoint of practical requirements. (author).
An introduction is presented on the radiation hazards connected with biomedical radiography and nuclear medicine. The frequency of radiodiagnostic efforts was rather high in the Netherlands. This was reduced considerably by abolishing the thorax screening of the population. About diagnostic nuclear medicine less can be said because far fewer numerical data are available. An exposition of genetically and somatically significant doses and how to compute them is given. The drawing up of a profit versus risk evaluation for medical applications of ionizing radiations is recommended. (Auth.).
The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.
A thermal neutron imaging facility for computed tomography and real-time neutron radiography is being developed at the University of Texas at Austin. The TRIGA reactor is a graphite-reflected Mark It pool-type research reactor. The neutron imaging facility will use beam port, which is at one end of a through part. Monte Carlo calculations were used to design the neutron collimator for this facility.
Magnetic resonance imaging can be used in the trauma setting to detect fractures and associated soft tissue injuries of the musculoskeletal system. Magnetic resonance imaging complements plain radiography and CT for evaluating cancellous bone, cartilage and growth-plate injuries, and intra- and extraarticular supporting soft tissue structures. This review outlines typical applications and imaging consideration for injuries of the pelvis and lower extremity. (orig.) With 12 figs., 78 refs.
Accidents from three main practices: medical applications, industrial radiography and industrial irradiators are used to illustrate some common causes of accidents and the main lessons to be learned. A brief description of some of these accidents is given. Lessons learned from the described accidents are approached by subjects covering: safety culture, quality assurance, human factors, good engineering practice, defence in depth, security of sources, safety assessment and monitoring and verification compliance. (author)
Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: (1) conventional radiography (CXR), (2) low kV conventional radiography (Low), (3) Fuji computed radiography (FCR), (4) bone images with conventional singles exposure energy subtraction (ES) and (5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, images of 42 lung nodules (21 calcified lung ...
Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: 1) conventional radiography (CXR), 2) low kV conventional radiography (Low), 3) Fuji computed radiography (FCR), 4) bone images with conventional singles exposure energy subtraction (ES) and 5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, images of 42 lung nodules (21 calcified lung ...
This book provides an analysis of pathophysiologic concepts of trauma and reviews the effectiveness of the available imaging modalities in acute trauma of various organ system. Topics covered are chest injuries; abdominal trauma; fractures of long bones; the foot and ankle; the knee; hand and wrist; the elbow; the shoulder; the pelvis hips; the spine; the skull and facial trauma and the clinical assessment of multiple injuries patients. Comparative evaluation of diagnostic techniques of radiography is discussed. Normal anatomy and bone fractures along with soft-tissue injuries are described.
In this study the development of a methodology to detect illicit drugs and plastic explosives is described with the objective of being applied in the realm of public security. For this end, non-destructive assay with neutrons was used and the technique applied was the real time neutron radiography together with computerized tomography. The system is endowed with automatic responses based upon the application of an artificial intelligence technique. In previous tests using real samples, the system proved capable of identifying 97% of the inspected materials.
We characterized the absorption and short-term translocation of cadmium (Cd) in rice (Oryza sativa ‘Nipponbare’) quantitatively using serial images observed with a positron-emitting...Full Text Available
A method for the quantitative determination of atmospheric hydroperoxyl radical comprising: (a) contacting a liquid phase atmospheric sample with a chemiluminescent compound which luminesces on contact with hydroperoxyl radical; (b) determining luminescence intensity from the liquid phase atmospheric sample; and (c) comparing said luminescence intensity from the liquid phase atmospheric sample to a standard luminescence intensity for hydroperoxyl radical. An apparatus for automating the method is also included.
Gas chromatography-selected ion monitoring-mass spectral analysis using [13C6]indole-3-acetic acid (IAA) as an internal standard provides an effective means for quantitation of...Full Text Available
A quantitative description is proposed for the depletion-induced slip thickness and velocity profile of a polymer solution near the wall-fluid interface in simple shear flow. The inhomogeneous polymer density profile at a flat wall is inserted into the equations of motion for the flow of a polymer solution near the flat wall. The theory is in quantitative agreement with simulation results. (letter to the editor)
A quantitative description is presented of the non-linear current-voltage response in superconducting niobium cavities for accelerator application. It is based on a fit for a large sample of data from cavity tests of different kind. Trial functions for the surface resistance describing this non-linear relation are established by a least square data fit. Those trial functions yielding the best fit are quantitatively explained by basic physics.
An (Awassi × Merino) × Merino backcross family of 172 ewes was used to map quantitative trait loci (QTL) for different milk production traits on a framework map of 200 loci across all...Full Text Available
Studies have been performed with an anti-osteogenic sarcoma monoclonal antibody 791T/36 and human tumour xenografts to examine some of the quantitative and kinetic aspects of tumour localization. The influence of variations in tumour size and site and antibody dose on the extent and rate of specific antibody localization have been examined, together with the site of intratumoural deposition of the antibody. (UK).
The overall objective of this project is to produce antibodies to unique modified DNA bases and develop immunochemical assays to quantitate these lesions in damaged DNA. During this past year we have developed an antibody and chemical test to quantitate a basic sites in DNA and produced antibodies to the 8-oxopurines. This report discusses the detection of a basic sites in DNA and the preparation of antibodies to 8-hydroxyadenine and 8-hydroxyguanine.
The need for noninvasive sensitive techniques for the diagnosis and follow-up of metabolic bone disease in dialysis patients has stimulated the author's interest in the efficacy of more detailed quantitative bone scintigraphy. Using hemodialysis to reduce elevated soft-tissue activity at scintigraphy, an attempt was made to assess the diagnostic sensitivity of quantitative bone scintigraphy as compared to qualitative bone scintigraphic, biochemical, radiographic and bone histologic studies. The second aim of these studies was to determine if one of the two major components of renal osteodystrophy is a major determinant for skeletal radiotracer uptake. The clinical observations on the efficacy and possible specificity of quantitative bone scintigraphy in the diagnosis and follow-up during treatment of renal osteodystrophy are presented briefly in this chapter. Thus, the use of scintigraphy for the routine detection and ...
Process control transmitters that incorporate digital signal processing could be used advantageously in nuclear power plants; however, because such transmitters are too sensitive to radiation, they are not used. The Electric Power Research Institute sponsored work at Sandia National Laboratories under EPRI contract RP2614-58 to determine why SMART transmitters fail when exposed to radiation and to design and demonstrate SMART transmitter circuits that could tolerate radiation. The term ''SMART'' denotes transmitters that contain digital logic. Tests showed that transmitter failure was caused by failure of the complementary metal oxide semiconductors (CMOS)-integrated circuits which are used extensively in commercial transmitters. Radiation-hardened replacements were not available for the radiation-sensitive CMOS circuits. A conceptual design showed that a radiation-tolerant transmitter could be constructed. A prototype for an ...
The purpose of this study is to investigate the possibility of verifying depleted uranium (DU), natural uranium (NU), low enriched uranium (LEU) and high enriched uranium (HEU) by a developed digital gamma-gamma coincidence spectroscopy. The spectroscopy consists of two NaI(Tl) scintillators and XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The results demonstrate that the spectroscopy provides an effective method of "2"3"5U and "2"3"8U quantification based on the count rate of their gamma-gamma coincidence counting signatures. The main advantages of this approach over the conventional gamma spectrometry include the facts of low background continuum near coincident signatures of "2"3"5U and "2"3"8U, less interference from other radionuclides by the gamma-gamma coincidence counting, and region-of-interest (ROI) imagine analysis for uranium enrichment determination. Compared to conventional gamma spectrometry, the method ...
The hurried development of multimedia and internet allows for wide distribution of digital media data. It becomes much easier to edit, modify and duplicate digital information. In additional, digital document is also easy to copy and distribute, therefore it may face many threats. It became necessary to find an appropriate protection due to the significance, accuracy and sensitivity of the information. Furthermore, there is no formal method to be followed to discover a hidden data. In this paper, a new information hiding framework is presented.The proposed framework aim is implementation of framework computation between advance encryption standard (AES) and distortion technique (DT) which embeds information in image page within executable file (EXE file) to find a secure solution to cover file without change the size of cover file. The framework includes two main functions; first is the hiding of the information in the ...
This report describes development of an electronic system designed to reduce vibration generated by a cryocooler. The diminished vibration makes it practical to use the active cooler to extract heat from a portable gamma ray detector instrument. The system was developed for a Sunpower cryocooler with an integrated counterbalance mass. The overall momentum cancellation approach is also applicable to other similar cryocoolers. The cancellation system is an assembly of several components tailored to accomplish the required vibration reduction with minimum power consumption and volume. It is designed to be powered by a 18--32 Volt battery. Up to ten harmonics of the 58.65 Hz drive frequency are controlled. In addition to the vibration cancellation, the electronic system produces the drive signal for the cryocooler and regulates the cooler temperature. The system employs a sinusoidal drive to reduce the amount of higher harmonic vibration. A digital signal processor ...
Verification and validation issues have been perceived as important factors in the large scale deployment of knowledge-based digital systems for plant transient diagnostics and management. Research and development (R&D) is being performed on the IGENPRO package to resolve knowledge base issues. The IGENPRO approach is to structure the knowledge bases on generic thermal-hydraulic (T-H) first principles and not use the conventional event-basis structure. This allows for generic comprehensive knowledge, relatively small knowledge bases and above all the possibility of T-H system/plant independence. To demonstrate concept feasibility the knowledge structure has been implemented in the diagnostic module PRODIAG. Promising laboratory testing results have been obtained using data from the full scope Braidwood PWR operator training simulator. This knowledge structure is now being implemented in the transient management module PROMANA to treat unanticipated events and ...
In the present investigation the performance of digital data acquisition (DA) and analogue data acquisition (AA) systems are compared in neutron-induced fission experiments. The DA results are practically identical to the AA results in terms of angular-, energy- and mass-resolution, and both compare very well with literature data. However, major advantages were found with the digital techniques. DA allows for a very efficient #alpha#-particle pile-up correction. This is important when considering the accurate measurement of fission-fragment characteristics of highly #alpha#-active actinide isotopes relevant for the safe operation of Generation IV reactors and the successful reduction of long-lived radioactive nuclear waste. In case of a strong #alpha#-emitter, when applying the #alpha#-particle pile-up correction, the peak-to-valley ratio of the energy distribution was significantly improved. In addition, DA offers a very flexible expanded ...
This paper reports on the detection of optical novae in our neighbour galaxy M31 based on digitized historical Tautenburg Schmidt plates. The accurate positions of the detected novae lead to a much larger database for searches for recurrent novae in M31. We conducted a systematic search for novae on 306 digitized Tautenburg Schmidt plates covering a time span of 36 years from 1960 to 1996. From the database of both ~ 300 000 light curves and about one million detections on only one plate per colour band, nova candidates were efficiently selected by automated algorithms and subsequently individually inspected by eye. We report the detection of 84 nova candidates. In detail we found 55 nova candidates from the automated analysis of the light curves. Among these, 22 were previously unknown, 12 were known but have not been identified on Tautenburg Schmidt plates before and 21 novae have been discovered on Tautenburg plates previously. An additional ...
Acute thoracic aortic injuries account for up to 10-20% of fatalities in high-speed deceleration road accidents and have an estimated immediate fatality rate of 80-90%. Untreated survivors to acute trauma (10-20%) have a dismal prognosis: 30% of them die within 6 hours, 40-50% die within 24 hours, and 90% within 4 months. It was investigated the diagnostic accuracy of Helical Computed Tomography (Helical CT) in acute traumatic injuries of the thoracic aorta, and the role of this technique in the diagnostic management of trauma patients with a strong suspicion of aortic rupture. It was compared retrospectively the chest Helical CT findings of 256 trauma patients examined June 1995 through August 1999. Chest Helical CT examinations were performed according to trauma score, to associated traumatic lesions and to plain chest radiographic findings. All the examinations were performed with no intravenous contrast agent administration and the pitch 2 technique. After a previous baseline ...
A Real-Time Operating System(RTOS) is an Operating System(OS) intended for real-time applications. Benchmarking is a point of reference by which something can be measured. The QNX is a Real Time Operating System(RTOS) developed by QSSL(QNX Software Systems Ltd.) in Canada. The ELMSYS is the brand name of commercially available Personal Computer(PC) for applications such as Cabinet Operator Module(COM) of Digital Plant Protection System(DPPS) and COM of Digital Engineered Safety Features Actuation System(DESFAS). The ELMSYS PC Hardware is being qualified by KTL(Korea Testing Lab.) for use as a Cabinet Operator Module(COM). The QNX RTOS is being dedicated by Korea Atomic Energy Research Institute (KAERI). This paper describes the outline and benchmarking test results on Context Switching, Message Passing, Synchronization and Deadline Violation of QNX RTOS under the ELMSYS PC platform
The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation doses absorbed within the critical organs - red bone marrow, lung, thyroid gland and female breast - and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. projection, the use of an abdominal compression device and careful caudal shielding of the field are advocated. (orig.).
An analysis is made of the basic principles and methods of construction of integrated optical circuits (IOC) for data processing, which are optical waveguide processors in the integrated form. A classification is provided of IOC in accordance with the nature of the input connections to optical components and in accordance with their intended function. An analysis is made of the current status of research and development of analog IOC for handling analog and digital signals, IOC for computing technology, and switching IOC. A detailed analysis is made of IOC with different functions in data processing: spectrum analyzers and correlators, analog-digital converters, circuits for identification of data sets and for encoding of signals, threshold and multistable circuits, logic and arithmetic units, and switching arrays. Descriptions are given of IOC for optically controlled data handling: bistable purely optical logic circuits, multivibrators, ...
Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)
A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.
We present a new modular traffic signs recognition system, successfully applied to both American and European speed limit signs. Our sign detection step is based only on shape-detection (rectangles or circles). This enables it to work on grayscale images, contrary to most European competitors, which eases robustness to illumination conditions (notably night operation). Speed sign candidates are classified (or rejected) by segmenting potential digits inside them (which is rather original and has several advantages), and then applying a neural digit recognition. The global detection rate is ~90% for both (standard) U.S. and E.U. speed signs, with a misclassification rate 150 minutes of video. The system processes in real-time ~20 frames/s on a standard high-end laptop.
In this work, a pre-cracked semi-circular shaped explosive simulant was loaded using a split Hopkinson pressure bar (SHPB). A high-speed camera was used to capture the deformation and fracture process of the specimen in situ. The digital images were processed using the digital image correlation (DIC) method. Next, full displacement and strain fields were obtained. The displacement vector field shows that the specimen fractured under tensile stress action. The strain field can be used to predict the crack propagation. Results show that the method of combined DIC and SHPB is effective to study the dynamic deformation and fracture behavior of explosive simulants. In addition, the specimen was loaded using a drop weight. The fracture toughness of the specimen was preliminary measured.
Considers fundamental problems involved in the precise location of faults on high-voltage transmission lines. The influence of pre-fault load on the distance-to-fault measurement problem is analysed and a new method of accounting for load effects is presented. Two of the algorithms considered are precise, containing no simplifyng assumptions and their overall accuracy is limited only by the accuracy of digital impedance relays at both ends of the protected circuit. A third algorithm presents a new approach to the fault location problem, which requires digital impedance relays at one end only of a transmission line. The procedures described are applicable to any system arrangement and are suitable for a wide range of fault resistance values.
The authors propose a method for determining the risk of femoral neck fracture in osteoporotic patients that is not based on densitometric techniques. The method is based on a structural analysis performed by a computer on data taken from a single digital anteroposterior projection of the hip. From the image, the effective cross-sectional area and cross-sectional moment of inertia are computed from attenuation principles. Together with other geometric measurements, these data are used in an engineering analysis to compute the yield strength of the proximal femur, under stress applied through the acetabulum in a one-legged stance. An index of fracture risk based on the ratio of estimated yield strength to body weight is proposed. Ultimately it is expected that this work will allow the clinician to estimate hip fracture risk in osteoporotic patient using widely available existing technology, a goal which has eluded bone density-based methods.
Digital libraries need more than just a retrieval based on keywords, which can be inefficient for some applications. Thus, a document retrieval based on content of the digitized image version of the document can be a more appropriated approach. This paper discusses the retrieval of document images by means of identifying a variety of elements present in the document's image body. We propose a new strategy to identify and combine features extracted from a document image. We also consider the task of constructing an optimized feature set to improve the retrieval performance and to validate our experiments on an assorted database. Experimental results show that the proposed segmentation together with a wisely feature combination increase the overall retrieval performance. Moreover the retrieved images demonstrate the generality and effectiveness of our approach for an efficient segmentation and classification of document images.
Graphical Business Process Modelling Languages (BPML) like Role Activity Diagrams (RAD) provide ease and flexibility for modelling business behaviour. However, these languages show limited applicability in terms of enactment over distributed systems paradigms like Service Oriented Architecture (SOA) based grid computing. This paper investigates RAD modelling of a Scientific Publishing Process (SPP) for Digital Libraries (DL) and tries to determine the suitability of Pi-Calculus based formal approaches to enact SOA based grid computing. In order to achieve this purpose, the Pi-Calculus based formal transformation from a RAD model of SPP for DL draws attention towards a number of challenging issues including issues that require particular design considerations for appropriate enactment in a SOA based grid system.
ABSTRACT Purpose: There is a consensus in the community of dental research that the selection of undersized artificial maxillary anterior teeth offers an unnatural appearance to the denture. Several methods to select the adequate width of these teeth are of questionable validity, and many dentures have an obviously artificial appearance. This article assessed the relationship between the individual and the combined width of maxillary anterior teeth. Materials and Methods: Impressions were made of the anterior dentition of 69 dentate undergraduate students with rubber impression silicon, and casts were formed. The individual widths of the maxillary anterior teeth were measured by using a digital caliper (SC-6 digital caliper, Mitutoyo Corporation, Tokyo, Japan), and the combined width was r...
A consideration is given to the problem of selecting optimized methods of radionuclide radiation registration during the control of the objects with essential changes in thickness. Adequate model of information signal formation is developed and analyzed for the case of the existence of an inertial link of the system with the dead time of a noncontinued type. The boundary values of radiation thickness and radiation flux intensity that divide the priority of using either digital or analog registration modes are revealed. The method is found for the full correction of a systematic error of flux intensity measurement because of the dead time of the apparatus. To control the objects with essential variation of thickness the method of selective measurement of radiation intensity is proposed
This document is furnished as part of the effort to develop NRC Class 1E Digital Computer Systems Guidelines which is Task 8 of USAF Rome Laboratories Contract F30602-89-D-0100. The report addresses four major topics, namely, computer programming languages, software design and development, software testing and fault tolerance and fault avoidance. The topics are intended as stepping stones leading to a Draft Regulatory Guide document. As part of this task a small scale survey of software fault avoidance and fault tolerance practices was conducted among vendors of nuclear safety related systems and among agencies that develop software for other applications demanding very high reliability. The findings of the present report are in part based on the survey and in part on review of software literature relating to nuclear and other critical installations, as well as on the authors' experience in these areas.
A Pulsed Radiation Dosimetry System designed to measure radiation produced by particle accelerators is described. The problems associated with total-dose measurement of irregular shaped pulses of ionizing radiation have been simplified. The system responds to extremely narrow pulses of charged particles or X-rays using a pin diode as the detector. Direct readout of dose in rads (Si) is displayed on a 3-1/2 digitdigital panel meter. The system will operate in either the multiple-pulse or single-pulse mode. The multiple-pulse mode would be useful in monitoring or tuning a linear accelerator. In the single-pulse mode the system will automatically display total dose of a transient event in real time and hold that measurement indefinitely or until the next measurement is made. The system features an automatic reset in either mode.
Research in the field of river hydrology has been mainly concerned with the investigation of the rainfall-runoff phenomenon through the analysis of hydrological factors such as meteorology and geography, with the focus being on each river basin. Recently, various forms of digital information such as GIS (Geographic Information System) and RS (Remote Sensing) data have been made available in worldwide digital map format. Therefore, there has been a shift in focus from lumped-parameter models to distributed runoff models, as the latter can consider temporal and spatial variations in water quantity. Distributed runoff models have made possible the comparison of runoff field and rainfall-runoff characteristics considering spatial distribution. Hydrological conditions are differently distribute...
Abstract Background: Aution Max AX-4030, a test strip analyzer recently introduced to the market, represents an upgrade of the Aution Max AX-4280 widely employed for urinalysis. This new instrument model can allocate two different test strips at the same time. In the present study the two instruments have been compared together with the usage of Uriflet 9UB and the recently produced Aution Sticks 10PA urine strips, the latter presenting an additional test area for the measurement of urinary creatinine. Methods: Imprecision and correlation between instruments and strips have been evaluated for chemical-physical parameters. Accuracy was evaluated for protein, glucose and creatinine by comparing the semi-quantitative results to those obtained by quantitative methods. The well-known interference effect of high ascorbic acid levels on urine glucose test strip determination was evaluated, ascorbic acid influence was also evaluated on protein and ...
This study assesses the current state of undergraduate instruction in empirical research methods in communication and offers recommendations for enhancing such instruction. Responses to an online questionnaire were received from 149 communication-related programs at four-year colleges and universities. Just over 85% of responding programs offered an empirical methods course. Although the course often covered both qualitative and quantitative methods, instruction was heavily slanted toward quantitative methods and topics common to both qualitative and quantitative inquiry. The empirical methods course was usually required for graduation, but it was typically not well integrated with the rest of the curriculum and taken late in students' undergraduate careers. Additional analyses examined st...
Fifteen quantitative bone scintigraphies were performed in an adolescent girl during the follow-up of a femoral osteogenic sarcoma treated by chemotherapy and massive allograft. Three hours after injection of the radiopharmaceutical (7.4 MBq/kg of 99mTc-MDP) bone activity was measured in the inferior limbs at several regions of interest centered on the hips, femurs (proximal, middle, distal) and proximal tibias. The variations of relative bone activities A/S (ratio of corresponding counting rates between two homologous regions in the affected A and in the healthy S limb) and of absolute bone activities (expressed in counts/pixel-second) are interpreted as a function of times during treatment. The quantitative results are discussed with regard to main phenomena influencing bone activity in this particular clinical case: bone growth, chemotherapy and neo-osteogenesis in allograft.
The Pacific white shrimp, Litopenaeus vannamei, is the most important shrimp species in volume in world aquaculture. However, in recent decades, outbreaks of diseases, especially viral diseases, have led to significant economic losses, threatening the sustainability of shrimp farming worldwide. In 2004, Brazilian shrimp farming was seriously affected by a new disease caused by the Infectious myonecrosis virus (IMNV). Thus, disease control based on rapid and sensitive pathogen detection methods has become a priority. In this study, a specific quantitation method for IMNV was developed using real-time PCR with SYBR Green chemistry and viral load of the principal target tissues of chronically infected animals was quantified. The quantitative analysis revealed that mean viral load ranged from ...
During the past three years the program has undergone a substantial revitalization. There has been no significant change in the scientific direction of this grant, in which emphasis continues to be placed on developing new or improved methods of obtaining quantitative data from radiotracer imaging studies. However, considerable scientific progress has been made in the three areas of interest: Radiochemistry, Quantitative Methodologies, and Experimental Methods and Feasibility Studies, resulting in a sharper focus of perspective and improved integration of the overall scientific effort. Changes in Faculty and staff, including development of new collaborations, have contributed to this, as has acquisition of additional and new equipment and renovations and expansion of the core facilities. 121 refs., 30 figs., 2 tabs.
To more accurately measure fluorescent signals from microarrays, we calibrated our acquisition and analysis systems by using groundtruth samples comprised of known quantities of red and green gene-specific DNA probes hybridized to cDNA targets. We imaged the slides with a full-field, white light CCD imager and analyzed them with our custom analysis software. Here we compare, for multiple genes, results obtained with and without preprocessing (alignment, color crosstalk compensation, dark field subtraction, and integration time). We also evaluate the accuracy of various image processing and analysis techniques (background subtraction, segmentation, quantitation and normalization). This methodology calibrates and validates our system for accurate quantitative measurement of microarrays. Specifically, we show that preprocessing the images produces results significantly closer to the known ground-truth for these samples.
Abstract Rationale, aims and objectives- Finding ways to incorporate disparate types of evidence into research syntheses has the potential to build a better evidence base for clinical practice and policy. Yet conducting such mixed research synthesis studies is challenging. Researchers have to determine whether and how to use adjusted and unadjusted quantitative findings in combination with each other and with qualitative findings. Methods- Among quantitative findings, adjustment for confounding, either via study design or statistical analysis, can be a considerable source of heterogeneity. Yet there is no consensus about the best way to synthesize findings resulting from different methods for addressing confounding. When synthesizing qualitative and quantitative findings, additional consid...
A clinical laboratory evaluation was conducted on the Clinitek Auto 2000, the Super Aution Analyzer and the Urotron RL9 for the determination of glucose, protein, pH, blood, ketone-bodies and bilirubin.Precision of the systems was tested using three commercial control urine materials, and reported as the percentage of times the instrument repeats a certain value. Good repeatability was obtained with all the instruments.Accuracy of the systems was evaluated by comparison with quantitative procedures, and to check agreement between methods yielding semi-quantitative and quantitative results, ranges of acceptability were defined, based on the criteria reported in a previous paper [2]. It was then found that 87.5 to 98.9% of results from the Urotron RL9 and the Clinitek Auto 2000 were acceptable. With the Super Aution Analyzer the level of agreement was apparently lower because of the higher number of concentration steps used ...
Secondary ischemic necrosis of femoral head due to loss of blood supply following to femoral neck fracture is well known. The regional distribution of bone-seeking radiopharmaceuricals in the skeleton can depend on a number of factors, but bone blood flow is a major physiological determinant of regional skeletal uptake of Tc-99m polyphosphate and bone imaging may thus be used for the evaluation of vascularity of the femoral head. The authors made a comparative study of scintigraphic findings and operative findings of 28 cases of femoral neck fracture treated at Kyung Hee University Hospital from April 1980 to May 1984. The results were as follows: 1. In 16 cases of proven avascular necorsis of femoral head, scintigraphy showed absent or decreased activity in 14 cases (87.5%), while radiography showed increased density in 10 cases (62.5%). 2. In 12 cases of proven vital femoral head, scintigraphy showed increased activity in 9 cases (75%) and ...
Xeroradiography (XR) was retrospectively compared with a newly developed computed radiography (FCR) for diagnostic availability for breast cancer. FCR provides with the image processed by a computer. Subjects were 65 breast cancer patients for XR and 51 for FCR. Both methods were performed preoperatively. No significant difference was observed in distribution of age between the two groups but the average tumor size in XR group was larger than that in FCR group. Tumor shadow appeared in 44 of 65 xeromammograms (67.7%) and in 34 of 51 computed radiograms (66.7%). Microcalcification was detected in 27 of 65 xeromammograms (41.5%) and in 21 of 51 computed radiograms (41.2%). Consequently, diagnosis of breast cancer could be achieved in 47 of 65 patients (72.3%, established: 39, suspective: 8) through XR and in 41 of 51 (80.4%, established: 33, suspected: 8) through FCR. Thus FCR is thought to be more useful for breast cancer because it not only offers good diagnostic ...
Xeroradiography (XR) was retrospectively compared with a newly developed computed radiography (FCR) for diagnostic availability for breast cancer. FCR provides with the image processed by a computer. Subjects were 65 breast cancer patients for XR and 51 for FCR. Both methods were performed preoperatively. No significant difference was observed in distribution of age between the two groups but the average tumor size in XR group was larger than that in FCR group. Tumor shadow appeared in 44 of 65 xeromammograms (67.7%) and in 34 of 51 computed radiograms (66.7%). Microcalcification was detected in 27 of 65 xeromammograms (41.5%) and in 21 of 51 computed radiograms (41.2%). Consequently, diagnosis of breast cancer could be achieved in 47 of 65 patients (72.3%, established: 39, suspective: 8) through XR and in 41 of 51 (80.4%, established: 33, suspected: 8) through FCR. Thus FCR is thought to be more useful for breast cancer because it not only offers good diagnostic ...
We have been developing an innovative Steam Generator concept of Fast Breeder Reactors by using liquid-liquid direct contact heat transfer. In this concept, the SG shell is filled with a molten alloys, which is heated by primary sodium. Water is fed into the high temperature molten alloy, and evaporates by direct contact heating. In order to obtain the fundamental information to discuss the heat transfer mechanisms of the direct contact between the water and the alloy, this phenomenon was visualized by real-time neutron radiography. JRR-3M real-time thermal neutron radiography in Japan Atomic Energy Research Institute was used. Followings are main results. (1) The vigorous evaporation occurs in the molten alloy. This phenomena is different from the known phenomenon such as the evaporation of refrigerant R-113 in the water. (2) The evaporation in the bubble has finished in a moment due to high heat transfer performance between the liquid and ...
In a breeder-type nuclear power plant, liquid metal is used as a coolant due to the high heat capacity factor. Also, some proposals for fusion reactor blanket design include liquid metal as a possible coolant. In both cases the understanding of natural circulation of liquid-metal flow behavior is an integral part of the thermal hydraulic analysis, especially under two-phase flow conditions. Experimental investigations have been conducted to study a liquid metal two-phase natural circulation flow system. A lead-bismuth (PbBi) eutectic mixture is used as a working fluid in a heated metal walled natural circulation loop. Gas injection induces natural circulation through the gas-lift mechanism. A real-time neutron radiography system is used to visualize the two-phase mixture, specifically the interface and the flow regime. Measurements of void fraction, void fluctuation and bubble propagation are performed.
In a breeder-type nuclear power plant, liquid metal is used as a coolant due to the high heat capacity factor. Also, some proposals for fusion reactor blanket design include liquid metal as a possible coolant. In both cases the understanding of natural circulation of liquid-metal flow behavior is an integral part of the thermal hydraulic analysis, especially under two-phase flow conditions. Experimental investigations have been conducted to study a liquid metal two-phase natural circulation flow system. A lead-bismuth (PbBi) eutectic mixture is used as a working fluid in a heated metal walled natural circulation loop. Gas injection induces natural circulation through the gas-lift mechanism. A real-time neutron radiography system is used to visualize the two-phase mixture, specifically the interface and the flow regime. Measurements of void fraction, void fluctuation and bubble propagation are performed.
As part of a U.S. multi-regional pilot study conducted by the six Centers for Radiological Physics, 12-mm-diameter by 0.4-mm-thick CaSO/sub 4/:Dy Teflon-embedded discs were evaluated and used to measure patient entrance exposure on 60 average patients at 12 clinical centers. The discs were found to have adequate sensitivity, reproducibility and linearity up to 69.7 microC kg-1 (270 mR). The minimum measurable exposure was estimated as 0.4 microC kg-1 (1.5 mR). All responses were corrected for energy dependence, which varied +/- 20% from 1.7 to 6.5 mm Al half-value layer. Patient entrance exposure values ranged from 1.3 to 28 microC kg-1 (5 to 110 mR), with a median value of 5.2 microC kg-1 (20 mR). This value agreed with exposure measurements made on the chest radiography equipment using an ionization chamber and a phantom which simulated an average patient, and with published Nationwide Evaluation of X-Ray Trends (NEXT) data for the same period.
Previous flow regime studies have been for horizontal, vertical, and inclined pipe flow. As such, only a few studies have been performed on bundle geometries. The present paper examines the flow regimes for a vertical hexagonal flow channel with and without a finned fuel bundle. This type of a 36 finned rod hexagonal fuel bundle in parallel hexagonal flow channels is used in a MAPLE (Multi- purpose Applied Physics Lattice Experimental) type nuclear reactor. An experiment apparatus was designed consisting of the flow channel, inlet plenum and an air-water separator. The inlet plenum is used to provide a uniform mixture of air and water before entering the hexagonal flow channel. A turbine flow meter is used to determine the water flow rate. The turbine flow meter is calibrated for a low flow range and limits the measurable flow to 50 l/min. Flow pattern observation is determined by a SONY video camera, Real-Time Neutron Radiography, pressure transducer and ...
A system for real-time neutron radiography of moving objects is described. It comprise a source adapted to generate a continuous uninterrupted series of neutron pulses. Each pulse has a predetermined peak power and duration compatible with the framing times of a real-time video imaging system. A transporter moves an object to be examined to bring sequentially position selected portions of the object in the path of the pulses. Where the object itself has moving components, pulses are sequentially incident on the object. According to any dissimilarities, the object will alter the intensity of the neutrons passing therethrough. In order to record separately the changes in the neutron intensity, for each pulse, an imager is positioned to receive the neutron beam pulses which have been altered by their passage through the object and produce images indicating intensity alterations. A refrigerated beryllium filter can be used to effectively eliminate thermal neutrons from ...
A system for real-time neutron radiography of moving objects is described. It comprise a source adapted to generate a continuous uninterrupted series of neutron pulses. Each pulse has a predetermined peak power and duration compatible with the framing times of a real-time video imaging system. A transporter moves an object to be examined to bring sequentially position selected portions of the object in the path of the pulses. Where the object itself has moving components, pulses are sequentially incident on the object. According to any dissimilarities, the object will alter the intensity of the neutrons passing therethrough. In order to record separately the changes in the neutron intensity, for each pulse, an imager is positioned to receive the neutron beam pulses which have been altered by their passage through the object and produce images indicating intensity alterations. A refrigerated beryllium filter can be used to effectively eliminate thermal neutrons from ...
In the Institute for Atomic Energy, Rikkyo University, just after the TRIGA-2 research reactor of 100 kW has attained the criticality, the cylindrical box for neutron radiography (NR) irradiation was made in the attached pool, and the research on NR was started in 1961. Thereafter in 1985, the vertical irradiation pipe was installed in the reactor tank, and the experiment for collecting the basic data was begun. In 1986, based on the obtained data, the NR irradiation facility on full scale was installed in No. 2 tangential horizontal experimental hole. As the main NR irradiation facilities, the vertical neutron irradiation pipe, the use of which is stopped now, the NR facility using the horizontal experimental hole (RUR/N2), the irradiation facility and ancillary facilities such as beam shutter, beam catcher and hoist are described. As the main equipments for NR, the imaging apparatuses of cooled type CCD, SIT and superhigh sensitivity, the image processors of ...
The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of monitoring any changes in the real-time system, including both the neutron ...
The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of monitoring any changes in the real-time system, including both the neutron beam and the electronic components. This paper ...
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray CT technique. (orig.).
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray CT technique. (orig.).
This works evaluates by punctuation the performance in conventional Brazilian industries radiation protection area which make use of small industrial gauges and industrial radiography. It proposes, procedures for industry self-evaluation, besides a new radiation protection plans pattern for the small industrial gauges area. The data source where inspection reports of Dosimetry Radiation Protection Institute/Nuclear Energy Commission conventional Brazilian industries' radiation protection plans, beyond visitation to the inspection place. The performance evaluation has been realized both in the administrative and operational aspects of the industries. About of 60% of the industries have a satisfactory register control which does not happen to the operational control. The performance evaluation advantage is that industries may self-evaluate, foreseeing Dosimetry Radiation Protection Institute's regulation inspections, correcting its irregularities, ...
The objective of this work is the measurement of two-phase flow parameters to support development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR). A single element finned Fuel Element Simulator was used with R134a Freon flow. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distributions were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly limits any significant vibration and the local void distribution ...
The objective of this work is the measurement of two-phase flow parameters to support development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR). A single element finned Fuel Element Simulator was used with R134a Freon flow. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distributions were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly limits any significant vibration and the local void distribution ...
The fast breeder test reactor at Kalpakkam has completed nearly 25 years of operation and is now operating at 18 MWt capacity with 46 fuel subassemblies (FSA) in the core consisting of 27 Mark-I (70% PuC + 30% UC), 13 Mark-II (55% PuC + 45% UC) and 6 MOX (44% PuO_2 + 56% UO_2) and one test PFBR FSA. Post Irradiation Examination (PIE) campaigns on FSAs at different burnup levels has provided valuable information about the irradiation behavior of the carbide fuel. This paper gives a summary of the irradiation performance of the carbide fuel evaluated through some of the investigations such as neutron radiography, x-radiography, gamma scanning, fission gas analysis and ceramography. Burnup of the carbide fuel could be enhanced from the initial design burnup limit of 50 GWd/t to 165 GWd/through systematic PIE. (author)
A Real-Time Neutron Radiography (RTNR) system is used to determine two-phase flow parameters for a horizontal co-current two-phase flow channel with a CANDU-type 37 rod bundle. Image processing techniques are applied to visualize the two-phase flow, and to determine flow regime, cross-sectional averaged void fraction, time averaged void fraction, and void distribution. The experimentally determined flow regime map disagrees with existing flow regime models developed for the CANDU-type rod bundles. A new flow regime is observed and designated Large Amplitude Stratified Wavy flow. The results show that the LASW flow regime may be due to a combination of undeveloped flow phenomena, boundary conditions, and circumferential cross flow occurring in the bundle. The rods in the bundle may act as a dampener to the vertical flow and hinders the development of the wave into plug or slug flow by changing the momentum of the fluid in the circumferential direction. The effect of ...
A real-time neutron radiography (RTNR) system is used to determine two-phase flow parameters for a horizontal co-current two-phase flow channel with a cylindrical 37 rod bundle. Image processing techniques are applied to visualize the two-phase flow, and to determine flow regime, cross-sectional averaged void fraction, time averaged void fraction, and void distribution. The experimentally determined flow regime map disagrees with existing flow regime models developed for the cylindrical rod bundles. A new flow regime is observed and designated large amplitude stratified wavy (LASW) flow. The results show that the LASW flow regime may be due to a combination of undeveloped flow phenomena, boundary conditions, and circumferential cross flow occuring in the bundle. The rods in the bundle may act as a dampener to the vertical flow component and hinders the development of the wave into plug or slug flow by changing the momentum of the fluid in the circumferential ...
A Real-Time Neutron Radiography (RTNR) system is used to determine two-phase flow parameters for a horizontal co-current two-phase flow channel with a CANDU-type 37 rod bundle. Image processing techniques are applied to visualize the two-phase flow, and to determine flow regime, cross-sectional averaged void fraction, time averaged void fraction, and void distribution. The experimentally determined flow regime map disagrees with existing flow regime models developed for the CANDU-type rod bundles. A new flow regime is observed and designated Large Amplitude Stratified Wavy flow. The results show that the LASW flow regime may be due to a combination of undeveloped flow phenomena, boundary conditions, and circumferential cross flow occurring in the bundle. The rods in the bundle may act as a dampener to the vertical flow and hinders the development of the wave into plug or slug flow by changing the momentum of the fluid in the circumferential direction. The effect of ...
The measurement of two-phase flow parameters and development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR) is discussed in this paper. A single element finned Fuel Element Simulator (FES) was used with R134a Freon as the working fluid. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distribution were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly limits any significant vibration and the local void ...
The measurement of two-phase flow parameters for development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR) is discussed in this paper. A single element finned Fuel Element Simulator (FES) was used with Freon 134a as the working fluid. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer present. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distribution were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly limits any significant vibration and the local ...
The study compares the doses absorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations. [Italian] Questo lavoro intende confrontare le dosi assorbite nel distretto dento-mascellare, con le due principali tecniche utilizzate in questo campo: TC spirale e ortopantomografia. Emerge come l'esame panoramico delle arcate dentarie eseguito con l'ortopantomografo comporti la'ssorbimento di dosi inferiori rispetto a quelle dell'esame TC spirale con programma Dentascan. Questi dati, pur essendo soggetti a variabilita' dovuta alla ...
Radiographic images generated by the real-time neutron radiography system (RTNR) are analyzed by customized image processing software of the determination of instantaneous void fraction distribution. The cross-sectional averaged axial void fraction profiles and the two-dimensional void fraction profiles are determined simultaneously for each image. Various flow regimes are generated to determine if the RTNR system can accurately predict the void distribution in the radial, axial, and temporal coordinates. The results show the RTNR system correctly determines the void fraction distribution for each flow regime; however, accuracy decreases with decreasing void fraction. For net water thicknesses > 1.0 cm, the accuracy decreases with increasing water thickness due to the extreme sensitivity of thermal neutron interactions with light water. Heavy water is a more suitable fluid than light water for void fraction measurements in large-diameter flow systems.
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,{theta}) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,#theta#) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.
The relationship between serum PG I, PG II levels and extent of atrophic gastritis was examined. The subjects were 64 patients (male: 32, female: 32, 51.9 years old on average) with established diagnosis of either atrophic gastritis or normal. In the X-ray gastric examination, Fuji Computed Radiography (FCR) was used to obtain clear-cut images of the gastric area. Concerning the serum PG I level, patients in the group with atrophic gastritis showed lower levels than those of the people in the group with no atrophic change, but the variation was wide, and no definite tendency was seen in the relationship between the atrophic change and the serum PG I levels. Concerning the serum PG II level, as the atrophic change progresses, the serum PG II level tended to increase gradually. A significant reduction in the PG I/II ratio was seen in the group with atrophic changes (p<0.01) in comparison with the group with no atrophic changes, and the PG I/II value tended to ...
The relationship between serum PG I, PG II levels and extent of atrophic gastritis was examined. The subjects were 64 patients (male: 32, female: 32, 51.9 years old on average) with established diagnosis of either atrophic gastritis or normal. In the X-ray gastric examination, Fuji Computed Radiography (FCR) was used to obtain clear-cut images of the gastric area. Concerning the serum PG I level, patients in the group with atrophic gastritis showed lower levels than those of the people in the group with no atrophic change, but the variation was wide, and no definite tendency was seen in the relationship between the atrophic change and the serum PG I levels. Concerning the serum PG II level, as the atrophic change progresses, the serum PG II level tended to increase gradually. A significant reduction in the PG I/II ratio was seen in the group with atrophic changes (p<0.01) in comparison with the group with no atrophic changes, and the PG I/II value tended to ...
To evaluate the diagnostic accuracy of Fuji computed radiography (FCR) in the detection of interstitial pulmonary infiltrates, FCR life-size images at a pixel size of 0.1 mm were compared with conventional radiographs taken on the same day. Seventeen radiologists assessed the radiographs and FCR images of 56 cases, including 39 cases of various interstitial lung diseases such as interstitial pneumonia, pulmonary abnormalities associated with collagen disease, sarcoidosis, multiple pulmonary metastases, diffuse panbronchiolitis and pulmonary emphysema, and 17 normal controls. All of the pulmonary abnormalities were confirmed by high resolution CT. Observer performance tests were carried out using receiver operating characteristic analysis. In 21 cases of increased pulmonary density revealed by high resolution CT, FCR was significantly superior to conventional radiographs in the detection of reticular or linear shadows. In 11 cases of subtle interstitial ...
To evaluate the diagnostic accuracy of Fuji computed radiography (FCR) in the detection of interstitial pulmonary infiltrates, FCR life-size images at a pixel size of 0.1 mm were compared with conventional radiographs taken on the same day. Seventeen radiologists assessed the radiographs and FCR images of 56 cases, including 39 cases of various interstitial lung diseases such as interstitial pneumonia, pulmonary abnormalities associated with collagen disease, sarcoidosis, multiple pulmonary metastases, diffuse panbronchiolitis and pulmonary emphysema, and 17 normal controls. All of the pulmonary abnormalities were confirmed by high resolution CT. Observer performance tests were carried out using receiver operating characteristic analysis. In 21 cases of increased pulmonary density revealed by high resolution CT, FCR was significantly superior to conventional radiographs in the detection of reticular or linear shadows. In 11 cases of subtle interstitial ...
Many mechanical parts are subjected to stresses and strains that may eventually lead to their failure. In order to prevent the costly delays associated with equipment down-time, many parts have to be tested for weaknesses and defects when machinery is constructed or dismantled for maintenance. These procedures are known as Non-Destructive Testing (NDT) methods. Five types of non-destructive testing methods routinely used are radiographic testing, ultrasonic testing, magnetic particle inspection, liquid penetrant testing and eddy current testing. Out of these five techniques industrial radiography plays an important role in non-destructive testing to reveal interior defects in materials. In radiography almost two-thirds of the radiation reaching the film is scattered radiation which does not form the image of defects. Scattered radiation generated inside and outside a material has a very large effect on sensitivity of flaw detection since it ...
Bubbly and slug flows have been analyzed using the afore-mentioned techniques. An image series of bubbly-slug flow is shown. The image separation time is 17 ms, and the total flow length is {approx} 10 cm. A circular eddy pattern that follows the slug can be readily seen and tracked, although reliability is low due to motion in the transverse direction. This motion also adds considerable error to the velocity measurements using image recognition technique. This will increase the reliability and accuracy of the tracking method.
We report a case of stress fracture of the clavicle associated with sternocostoclavicular hyperostosis. A 60-year-old man sustained a stress fracture of the right clavicle with no history of trauma. On radiography, hyperostosis of the anterior chest wall and ankylosis of the sternoclavicular joint were evident in addition to the fracture. Fracture healing was uneventful after 2.5 months. Ankylosis of the sternoclavicular joint may have caused increased stress at the midshaft of the clavicle by daily activity or minor trauma. Such a fracture is a rare complication of sternocostoclavicular hyperostosis. (orig.)
The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.
The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).
Periosteal Ewing's sarcoma is an uncommon, but well documented origin of this malignant condition with radiography signs, different from intramedullary growing tumours. Imaging modalities like CT or MRI supply proof of macroscopically intact endosteal cortical surface and free medullary cavity in long bones affected by this periosteal type of malignancy. Definite confirmation is valid after a careful microscopic investigation of the resected specimen. The prognosis of this type of Ewing's sarcoma may be favourable than that of the central type. Early diagnosis and therapy are thus essential. A clinical survey of six observations is given. (orig.).
The repeated use and limited lifetime of a composite tiring vessel compel a need to survey techniques for monitoring the structural integrity of the vessel in order to determine when it should be retired. Various nondestructive techniques were researched and evaluated based on their applicability to the vessel. The methods were visual inspection, liquid penetrant testing, magnetic particle testing, surface mounted strain gauges, thermal inspection, acoustic emission, ultrasonic testing, radiography, eddy current testing, and embedded fiber optic sensors. It was determined that embedded fiber optic sensor is the most promising technique due to their ability to be embedded within layers of composites and their immunity to electromagnetic interference.
To improve the detection rate of lung cancer, we have introduced low-dose CT and CR technique into a population-based annual mass screening. From December 1999, 3868 and 12618 individuals participated in this screening program with CT and with CR, respectively. Primary lung cancer was detected in 15 (0.39%) by CT and 8 (0.06%) by CR. This results show high detection rate of primary lung cancer as had been previously reported. (author)
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has been developed at the University of Texas reactor. The facility produced good-quality radiographs and two-dimensional tomograms. Further developments have been recently accomplished. A computer software has been developed to automate and expedite the data acquisition and reconstruction processes. Volume tomographic visualization using Interactive Data Language (IDL) software has been demonstrated and will be further developed. Volume tomography provides the additional flexibility of producing slices of the object using software and thus avoids redoing the measurements.
A 1.5-year-old male Belgian Malinosis Military Working Dog presented with a 1-month history of intermittent hematuria. Diagnostic ultrasound and contrast radiography demonstrated large blood clots in the urinary bladder and a filling defect in the right renal pelvis. At surgery, clotted blood was present in the right ureter and bladder. Following right nephrectomy, the dog returned to training. One month later, elevations in urea nitrogen and creatinine were noted. Hematuria recurred at 3 months and the dog was found dead in its kennel. Necropsy showed a blood-filled left renal pelvis and ureter. PMID:1454185
Thermal neutron beam from the TNRF of JRR-3M was utilized for detection of mice lung cancer in vivo. Both the static and real-time neutron imaging were tried. Very strong thermal neutron beam is necessary to detect lung cancers because small changes are hidden by the very large attenuation of thermal neutron beam by the hydrogens in the tissues. The detection was successfully performed. Especially, the Super Eye of Hamamatsu Photonics contributed very effectively. Bone marrows and cartilages were also shown clearly. If an efficient and compact neutron source will become available in future, this method will grow up as a powerful tool for biomedical application. (author).
The goal of this research program has been to add to our understanding of the breakup of molten fuel jets penetrating reactor coolant. Easily handled working fluids are used to simulate fuel jet breakup, so that detailed observations may be obtained from a relatively large number of experiments. The tools used for observing this behavior are high speed notion picture photography, Flash X-radiography, and X-ray cine. Jet breakup lengths are determined from motion pictures; the mechanisms by which the jets are fragmented may be inferred from radiographs.
Eighty-seven subtraction images of FCR were compared with subtraction images of conventional angiography. Although FCR images with reduced exposure dose (25 % of regular dose) and with diluted contrast material (150 mgI/ml, 50 % of usual concentration) were slightly inferior to the images of conventional angiography, most clinically important vessels were adequately visualized. As FCR has wider dynamic range and higher contrast resolution than conventional angiography, FCR may take over conventional angiography. (author).
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter.
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).
Supplementing the collection of artificial neural network methodologies devised for monitoring energy producing installations, a general regression artificial neural network is proposed for the identification of the two-phase flow that occurs in the coolant channels of boiling water reactors. The utilization of a limited number of image features derived from radiography images affords the proposed approach with efficiency and non-invasiveness. Additionally, the application of counter-clustering to the input patterns prior to training accomplishes an 80% reduction in network size as well as in training and test time. Cross-validation tests confirm accurate on-line flow regime identification.
Supplementing the collection of artificial neural network methodologies devised for monitoring energy producing installations, a general regression artificial neural network is proposed for the identification of the two-phase flow that occurs in the coolant channels of boiling water reactors. The utilization of a limited number of image features derived from radiography images affords the proposed approach with efficiency and non-invasiveness. Additionally, the application of counter-clustering to the input patterns prior to training accomplishes an 80% reduction in network size as well as in training and test time. Cross-validation tests confirm accurate on-line flow regime identification.
With iWork '09: The Missing Manual, you'll quickly learn everything you need to know about Apple's incredible productivity programs, including the Pages word-processor, the Numbers spreadsheet, and the Keynote presentation program that Al Gore and Steve Jobs made famous. This book gives you crystal-clear and jargon-free explanations of iWork's capabilities, advantages, and limitations to help you produce stunning documents and cinema-quality digital presentations in no time.
An automatic data-smoothing algorithm for data from digital oscilloscopes is described. The algorithm adjusts the bandwidth of the filtering as a function of time to provide minimum mean squared error at each time. It produces an estimate of the root-mean-square error as a function of time and does so without any statistical assumptions about the unknown signal. The algorithm is based on least-squares fitting to the data of cubic spline functions.
This paper describes the implementations of a fuzzy logic based self-tuned controller to improve the stability of electric power systems. The stabilizing signal is computed using the standard fuzzy membership function depending on the speed/acceleration state of the generator in the phase plane. The performance of the proposed stabilizer is demonstrated by practical implementation using a digital signal processor mounted on a PC-AT. Results of the experimental tests on a physical model of a power system are presented.
Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computer tomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained
The basic function of a Power System Stabilizer (PSS) is to add damping to the generator rotor oscillations by controlling its excitation using auxiliary stabilizing signals. To provide damping, the stabilizer must produce a component of electrical torque in phase with the rotor speed deviations. This paper introduces the hardware specifications and various functions of microprocessor (TMS320C32)-based digital PSS to provide the damping torque. (author). 3 refs., 6 figs.