Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitativeimage quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line ...
Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitativeimage quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more ...
Quantitativedigitalimaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitativeimage data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in ...
The purpose of this study was to investigate the feasibility of a simple deformable phantom as a QA tool for testing and validation of deformable image registration algorithms. A diagnostic thoracic imaging phantom with a deformable foam insert was used in this study. Small plastic markers were distributed through the foam to create a lattice with a measurable deformation as the ground truth data for all comparisons. The foam was compressed in the superior-inferior direction using a one-dimensional drive stage pushing a flat 'diaphragm' to create deformations similar to those from inhale and exhale states. Images were acquired at different compressions of the foam and the location of every marker was manually identified on each image volume to establish a known deformation field with a known accuracy. The markers were removed digitally from corresponding images ...
The aim of this study was to assess the possibility of digitalimage analysis of pit-and-fissure discoloration in order to diagnose caries. Digitalimages showing pit-and-fissure discoloration in 100...Full Text Available
The use of digital wound images would allow remote consultation between patients, physicians, or other caregivers over the Internet. To evaluate the efficacy and validity of digitalimages for assessment...Full Text Available
In the past, the need for high quality images, i.e., very sharp and clear images, in mammography have prevented mammography equipment from being digitalized; however, recent advances in detection technology such as development of a high resolution digital X-ray detector have produced improvements in digital mammography. Digital mammography is expected to replace conventional film-screen mammography. We have developed a digital mammography system, named ''SEPIO NUANCE DT'', which is equipped with a direct conversion flat panel detector. The present paper describes the high basic performance and user-friendly functions of the system. (author)
BackgroundThis in vitro study was conducted to compare the accuracy of two digitalimage receptors in identifying the location of tip of a fine endodontic file and radiographic apex...Full Text Available
The Digital Raster Graphic (DRG) is a raster image of a scanned USGS topographic map including the collar information, georeferenced to the UTM grid....
Computed radiography (CR) systems use a photostimulable phosphor plate enclosed in a cassette. In CR, image acquisition is a two-stage process wherein image capture and image read out are done separately. Direct digital radiography (DR) systems, on the other hand, use detectors that have a combined image capture and image read out capability. DR systems are also called as DDR or ddR systems by some vendors. This article focuses on DR systems
This paper describes Image Engine, an object-oriented, microcomputer-based, multimedia database designed to facilitate the storage and retrieval of digitized biomedical still images, video, and text...Full Text Available
Digitalimaging techniques such as DigitalImage Intensifier Radiography and Digital Storage Phosphor (Selenium) Radiography are replacing conventional film-screen radiography more and more. The aim of this development is the extension of diagnostic capabilities and the reduction of side effects such as radiation dose. Conventional film-screen radiography and digital radiography are very different ways of imaging. For digital radiography specific post-processing is the link between imaging conditions and film documentation. Optimisation of the images includes new possibilities of post-processing and a broad range for variation of the dose. Especially in fluoroscopy, dose can be reduced significantly by new technical features like pulsed fluoroscopy. For ...
Digitalimaging techniques such as DigitalImage Intensifier Radiography and Digital Storage Phosphor (Selenium) Radiography are replacing conventional film-screen radiography more and more. The aim of this development is the extension of diagnostic capabilities and the reduction of side effects such as radiation dose. Conventional film-screen radiography and digital radiography are very different ways of imaging. For digital radiography specific post-processing is the link between imaging conditions and film documentation. Optimisation of the images includes new possibilities of post-processing and a broad range for variation of the dose. Especially in fluoroscopy, dose can be reduced significantly by new technical features like pulsed fluoroscopy. For ...
Detailed three dimensional wing kinematics and aerodynamic characteristics are experimentally presented for the free flight of a beetle, Allomyrina dichotoma, which has a pair of elytra (fore wings) and hind wings. The kinematic parameters of the wing motion, such as the wing tip trajectory, angle of attack, torsion angle, and camber deformation, are obtained from a 3D reconstruction technique that involves the use of two or three synchronized high-speed cameras to digitize various points marked on the wings. Our data show outstanding characteristics of wing deformation and flexibility in the free flight of the beetle. To find out the mechanism of aerodynamic force, the leading edge vortex (LEV) and trailing edge vortex (TEV) on both elytron and hind wing were observed by using smoke wire visualization and digital particle image velocimetry (DPIV) technique. Qualitative smoke lines in the region of the most intent vortex ...
Mammography has emerged as a reliable non-invasive technique for the early detection of breast cancer--the second leading cause of cancer-related mortality among American women. The radiographic appearance of the female breast consists of radiolucent (dark) regions due to fat and radiodense (light) regions due to connective and epithelial tissue. The amount of radiodense tissue can be used as a marker for predicting breast cancer risk. This paper presents the development of an algorithm for estimating the percentage of radiodense tissue in a digitized mammogram. The technique involves determining a dynamic threshold for segmenting radiodense indications in mammograms. Both the mammographic image and the threshold are modeled as Gaussian random variables. This work is intended to support a concurrent study at the Fox Chase Cancer Center (FCCC) exploring the association between dietary patterns and breast cancer risk. Mammograms have been ...
Quantitative microscopy has been extensively used in biomedical research and has provided significant insights into structure and dynamics at the cell and tissue level. The entire procedure...Full Text Available
Digital radiography for diagnosis of chest diseases using Fuji Computed Radiography (FCR) was evaluated. The results were as follows; 1. Compared to the conventional chest X-ray films, various types of image enhancement could be made by manipulation of the digital information such as tone conversion, spatial frequency modification etc. 2. Digital radiography lessens the X-ray exposure dose and will ultimately permit speedy transmission of image data from outlying clinics to central processing hospitals. 3. Digital radiographic images are useful in chest X-ray diagnosis especially in mass surveys for lung cancer and in primary care medicine because of its full imaging capability. (author).
Purpose/Objective: At present, treatment verification between portal and reference images is performed based on manually-identified features by radiation oncologist, which is both time-consuming and potentially error-prone. There is a demand for the computerized verification procedure in clinical application. The purpose of this study is to develop a computerized portal verification scheme for pelvic treatment fields. Materials/Methods: The automated verification system involves image acquisition, image feature extraction, feature matching between reference and portal images and quantitative evaluation of patient setup. Electronic portal images with a matrix size of 256 x 256 and 12 bit gray levels were acquired using a liquid matrix electronic portal imaging device. Simulation images were acquired by ...
Several efforts have been made to completely automate cephalometric analysis by automatic landmark search. However, accuracy obtained was worse than manual identification in every study. The analogue-to-digital...Full Text Available
Radiology departments often underestimate the importance of protecting medical data during transmission, including the precautions taken to ensure data protection. In teleradiology, transmitted as well as stored patient data have to be signed digitally according to the currently valid regulation (Roentgenverordnung, RoeV). The DICOM standard facilitates a digital signature. So far, medical image manufacturers only announced to support this security feature. We introduce a solution that extends the feature of digital signing to older modalities. (orig.)
We have investigated the detection performance of GaAs detectors made with different thickness and contact geometries. A comparison is made between these detection capabilities and the imaging requirements for the following medical applications: digital mammography, digital chest radiography and nuclear medicine. Experimental results and preliminary images are presented and discussed. (author)
A diverse set of digitalimage-processing applications exists at the Lawrence Livermore National Laboratory. While many of these include some sort of image analysis or restoration, virtually all of them require image-enhancement procedures. In this paper we describe the principal image-processing facility at the Laboratory, followed by a discussion of several of the major image-processing application areas.
The quantitativeimaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.
The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digitalimages by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ...
The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digitalimages by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ...
BackgroundMany three-dimensional (3D) images are routinely collected in biomedical research and a number of digital atlases with associated anatomical and other information have...Full Text Available
A high-speed fiber-based network for the transmission and display of digitized full-motion cardiac images has been developed. Based on Asynchronous Transfer Mode (ATM), the network is scaleable, meaning...Full Text Available
The field of a digital-image processing has experienced dramatic growth and increasingly widespread applicability in recent years. Fortunately, advances in computer technology have kept pace with the rapid growth in volume of image data in these and other applications. Digitalimage processing has become economical in many fields of research and in industrial and military applications. While each application has requirements unique from the others, all are concerned with faster, cheaper, more accurate, and more extensive computation. The trend is toward real-time and interactive operations, where the user of the system obtains preliminary results within a short enough time that the next decision can be made by the human processor without loss of concentration on the task at hand. An example of this is the obtaining of two-dimensional (2-D) computer-aided tomography (CAT) images. A ...
The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)
Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...
Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...
We present the results of an isophotal shape analysis of three samples of galaxies in the Coma cluster. Quantitative morphology, together with structural and photometric parameters, is given for each galaxy. Special emphasis has been placed on the detailed classification of early-type galaxies. The three samples are: i) a sample of 97 early-type galaxies brighter than m_B = 17.00 falling within one degree from the center of the Coma cluster; these galaxies were observed with CCD cameras, mostly in good to excellent resolution conditions; ii) a magnitude complete sample of 107 galaxies of all morphological types down to m_B = 17.00 falling in a circular region of 50 arcmin diameter, slightly offcentered to the North-West of the cluster center; the images for this and the next sample come from digitized photographic plates; iii) a complete comparison sample of 26 galaxies of all morphological types down to m_R = 16.05 (or m_B ...
A Digital X-ray imaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS ...
Low resolution visual polarimetric photographic imagery of the Galveston Bay oil spill from a tanker accident on July 28, 1990 was obtained and analyzed. The low resolution imagery (30 to 100 meters) was obtained concurrently with high resolution (1 meter), and is representative of what would be seen by a polarimetric satellite. Orthogonal red-green-blue (RGB) polarimetric images obtained with color photography were digitized by KODALUX on to a CD ROM. These polarimetric images were then used to calculate the percent polarization. The positive and negative percent polarized radiation scattered by each of the sea surface waves is seen individually in high resolution imagery. (Percent polarization is defined as positive when the dominant radiation is perpendicular to the plane of incidence and negative when it is parallel). The analysis of low resolution polarimetry is approached in a different manner than high resolution; in ...
Digital libraries need more than just a retrieval based on keywords, which can be inefficient for some applications. Thus, a document retrieval based on content of the digitizedimage version of the document can be a more appropriated approach. This paper discusses the retrieval of document images by means of identifying a variety of elements present in the document's image body. We propose a new strategy to identify and combine features extracted from a document image. We also consider the task of constructing an optimized feature set to improve the retrieval performance and to validate our experiments on an assorted database. Experimental results show that the proposed segmentation together with a wisely feature combination increase the overall retrieval performance. Moreover the retrieved images demonstrate the generality and ...
Objective: To evaluate the quality and usefulness of direct digital radiography system in roentgenogram of chest in clinical practice. Methods: 1000 cases of chest roentgenograms with digital radiography and high kV conventional radiography were selected for analysis by 3 senior radiologists. Results: 1. With digital radiography system, the quality of chest film was assessed as grade A in 50.6%, grade B in 38.5%, grade C in 10.9%, and no waste film. 2. With conventional high kV radiography, the quality of chest film was assessed as grade A in 41.1%, grade B in 44.1%, grade C in 13.3%, and waste film in 1.5%. The direct digital radiography was statistically superior to the conventional high kV radiography. 3. The fine structure of the lungs could be revealed in 100.0% of chest roentgenogram with direct digital radiograph system, which was significantly higher than that acquired with ...
Present day mammography has not been able to make use of the advantages of digital luminescence radiography because of the limited spatial resolution. The recent development of electromagnetic focusing X-ray tube with effective focal spot sizes from 0.04 to 0.12 mm allows radiographic direct magnification with less geometric blur. It is now possible to combine direct magnification mammography with digital luminescence radiography. By combining high quality storage phosphor screens with an HQ-workstation a spatial resolution of 8 lp/mm is possible for 1.7-fold magnification. For 4-fold spot magnification views spatial resolution can be theoretically increased to approx. 20 lp/mm. One important advantage of digital radiography is the possibility of image-postprocessing. This article presents two sets of standard parameters and three sets of image dependent parameters for better ...
Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly different. Conclusion: The ...
The use and application of remote sensing data for monitoring the environmental impacts of open cast lignite mining in Eastern Germany is described. This investigation is based on the digital analysis of several Landsat-TM and ERS-1 data sets acquired from 1989 to 1994. The characteristics of the imagery enable quantitative analysis of different open cast mine features, such as waste, water bodies, change of land use, reclamation processes and estimation of vegetation cover in the affected areas. On the basis of the Maximum Likelihood Classification of Landsat Thematic Mapper (TM) data the open cast mining areas were separated into bare open cast areas and areas of less and dense vegetation. The bare open cast areas were classified with respect to type of different sediments and the vegetation was seperated into different classes according to the age of the vegetation and the density cover. Apart from these, water bodies within the mining areas ...
Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point source results in a phase contrast too narrow for detection with CR. ...
This paper describes Fuji computed radiography (FCR) of Fuji Film for NDT (non-destructive testing). Imaging plate (IP) is a two-dimensional detector of X-ray, and shows higher photographic sensitivity than X-ray film. The output emission of IP provides a good linear relationship to X-ray intensity in a wide intensity range. When this emission can be digitized, the X-ray intensity can be also digitized. IP is applied to NDT as an inspection using X-ray. FCR provides higher photographic sensitivity than the conventional X-ray film method, which results in one-fifth to one-twentieth of irradiation time. Images with stable density can be obtained independent of the intensity. Since IP has a wide dynamic range, the variation of X-ray intensity of 1:500 can be expressed in a single image by single shot. High density record including 1000 images can be done using a ...
An algorithm for pose and motion estimation using corresponding features in images and a digital terrain map is proposed. Using a Digital Terrain (or Digital Elevation) Map (DTM/DEM) as a global reference enables recovering the absolute position and orientation of the camera. In order to do this, the DTM is used to formulate a constraint between corresponding features in two consecutive frames. The utilization of data is shown to improve the robustness and accuracy of the inertial navigation algorithm. Extended Kalman filter was used to combine results of inertial navigation algorithm and proposed vision-based navigation algorithm. The feasibility of this algorithms is established through numerical simulations.
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...
27 cases including 7 outpatients, underwent intraarterial DSA using 4-F nylon catheter, by transbrachial arterial approach. Much of DSAs were performed in Fuji Computed Radiography (FCR), which has high spatial resolution. In all cases, image quality satisfied clinical demands. No major complication occured in this series. Transbrachial arterial digital subtraction angiography is excellent and safe method for screening of vascular disease. (author).
Breast cancer represents today more than 30% of all cancers and is responsible for about 20% of deaths due to cancer. The potentialities of mammography have increased in recent years through improvements in equipment and methodologies. In this paper the conventional mammography using film and image intensifiers is compared with digital mammography. Digital mammography presents clear advantages in storage and handling of information. Also its higher sensitivity will lead to an earlier detection of anomalies and a decrease in the number of invasive exams and surgeries
Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management.
Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management. (orig.).
This flyover of the Hawaiian island of Oahu was made by draping Jan. 13, 2010, image data from the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) instrument on NASA's Terra spacecraft over new ASTER Version 2 digital elevation data.
We describe a decision support system to distinguish among hematology cases directly from microscopic specimens. The system uses an image database containing digitized specimens from normal...Full Text Available
1. Digitalimaging and photometry were used in conjunction with the fluorescent Ca2+ indicator, Fura-2, to examine intracellular Ca2+ signals produced by depolarization of single adrenal chromaffin...Full Text Available
A method of increasing information content for content-based image retrieval (CBIR) systems includes the steps of providing a CBIR database, the database having an index for a plurality of stored digitalimages using a plurality of feature vectors, the feature vectors corresponding to distinct descriptive characteristics of the images. A visual similarity parameter value is calculated based on a degree of visual similarity between features vectors of an incoming image being considered for entry into the database and feature vectors associated with a most similar of the stored images. Based on said visual similarity parameter value it is determined whether to store or how long to store the feature vectors associated with the incoming image in the database.
A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above ...
Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only ...
Purpose - This paper aims to discuss the procedures and methods developed at Washington State University to digitize and make accessible historic moving images. Design/methodology/approach - The paper describes the selection and the use of low-cost technologies to transfer analog film to digital formats. Issues related to the conversion, description, and online hosting of digital films are also addressed. Findings - Though the steps involved in digitizing film are not trivial, the benefits of access both for the public and archives staff outweigh the expense and labor involved. The procedures described in this paper involve low upfront costs and are sustained through cost recovery fees. Research limitations/implications - The focus of this paper is on managing, describing, and providing on...
We characterized the absorption and short-term translocation of cadmium (Cd) in rice (Oryza sativa ‘Nipponbare’) quantitatively using serial images observed with a positron-emitting...Full Text Available
The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...
We performed a comparative study of digitally and conventionally acquired images in gastrointestinal examinations. Radiation dose and spatial resolution were determined in a water phantom. In 676 examinations with either conventional or digitalimaging (system: Diagnost 76, DSI) the number of images and the duration of the fluoroscopy time were compared. 101 examinations with digital as well as conventional documentation were evaluated by using 5 criteria describing the diagnostic performance. The entrance dose of the DSI is 12% to 36% of the film/screen system and the spatial resolution of the DSI may be better than that of a film/screen system with a speed of 200. The fluoroscopy time shows no significant difference between DSI and the film/screen technique. In 2 of 4 examination modes significantly more images were produced by the DSI. ...
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are ...
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are ...
We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.
To more accurately measure fluorescent signals from microarrays, we calibrated our acquisition and analysis systems by using groundtruth samples comprised of known quantities of red and green gene-specific DNA probes hybridized to cDNA targets. We imaged the slides with a full-field, white light CCD imager and analyzed them with our custom analysis software. Here we compare, for multiple genes, results obtained with and without preprocessing (alignment, color crosstalk compensation, dark field subtraction, and integration time). We also evaluate the accuracy of various image processing and analysis techniques (background subtraction, segmentation, quantitation and normalization). This methodology calibrates and validates our system for accurate quantitative measurement of microarrays. Specifically, we show that preprocessing the images produces results ...
A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above ...
The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...
The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of gray scale and ...
The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of gray scale and ...
Oct 24, 1995 ... The photos were made with a Nikon FE and a Sigma 400mm APO f/5.6 lens ... Note: The JPEG images to which the above links point contain subtle ... India on 1995 October 24 with a digital camera and Fe X 6374 ? filter, ...
Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best ...
Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical ...
The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digitalimage processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost ...
The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digitalimage processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost ...
Acceptance testing of mammographic imaging systems technical is the first approach in order to guarantee that mammograms will be achieved with the minimum radiation dose compatible with an image quality suitable for diagnose purposes. The aim of this study is to assess the practical applicability of different protocols in acceptance test of digital mammographic systems. This study has been carried out on the results of the acceptance tests of five flat panel digital mammographic systems. Parameters established in the systems technical specifications and those evaluated in the consulted protocols were tested. Due to the fact that the legislation in our country does not demand to consider a specific protocol, the results obtained were also compared considering different existing protocols. Results show discrepancies between manufacturers limiting values and those established in the protocols. Some ...
A recent study reported the results of an exploratory study of alterations of the quantitative sleep profile due to the effects of a digital mobile radio telephone. Rapid eye movement (REM) was suppressed, and the spectral power density in the 8--13 Hz frequency range during REM sleep was altered. The aim of the present study was to illuminate the influence of digital mobile radio telephone on the awake electroencephalogram (EEG) of healthy subjects. For this purpose, the authors investigated 34 male subjects in a single-blind cross-over design experiment by measuring spontaneous EEGs under closed-eyes condition from scalp positions C{sub 3} and C{sub 4} and comparing the effects of an active and an inactive digital mobile radio telephone (GSM) system. During exposure of nearly 3.5 min to the 900 MHz electromagnetic field pulsed at a frequency of 217 Hz and with a pulse width of 580 {micro}s, the ...
Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digitalimage processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images. (author).
Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided ...
Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided ...
Purpose: Understanding the kinetics of tumor growth∕shrinkage represents a critical step in quantitative assessment of therapeutics and realization of adaptive radiation therapy....Full Text Available
Experimental and imaging studies in monkeys have outlined various long association fiber bundles within the temporoparietal region. In the present study the trajectory of the middle longitudinal fascicle...Full Text Available
Motivation: Cell tracking is an important method to quantitatively analyze time-lapse microscopy data. While numerous methods and tools exist for tracking cells in 2D time-lapse images,...Full Text Available
Quantitative metallography is often used to confirm the proper processing of aerospace metallic materials. A microstructural feature of great importance for titanium alloys processed in the alpha-beta phase field is the volume fraction of primary alpha. S...
Activatable or “smart” magnetic resonance contrast agents have relaxivities that depend on environmental factors such as pH or enzymatic activity, but the MR signal depends on...Full Text Available
The hurried development of multimedia and internet allows for wide distribution of digital media data. It becomes much easier to edit, modify and duplicate digital information. In additional, digital document is also easy to copy and distribute, therefore it may face many threats. It became necessary to find an appropriate protection due to the significance, accuracy and sensitivity of the information. Furthermore, there is no formal method to be followed to discover a hidden data. In this paper, a new information hiding framework is presented.The proposed framework aim is implementation of framework computation between advance encryption standard (AES) and distortion technique (DT) which embeds information in image page within executable file (EXE file) to find a secure solution to cover file without change the size of cover file. The framework includes two main functions; first is the hiding of the ...
In situ X-Ray microtomography offers new opportunities for analysing sintering mechanisms since it allows 3D observation of the microstructural evolution of the powder all along a sintering cycle. With synchrotron radiation at ESRF, a 3D image with a resolution of 2 {mu}m can be obtained in about one minute. In addition to the visual examination of the images, relevant microstructural parameters can be measured through quantitativeimage analysis using recently developed tools. In this paper the results obtained with two materials, loose copper powder and compacted steel powder, are resumed. For copper powder, the dispersion of local parameters such as particle co-ordination number and porosity is investigated. Concerning steel compacts, data about pore morphology evolution and on local strains provides clues for understanding the anisotropic shrinkage of such compacts. (authors)
Objective: To discuss the clinical application value of dual energy subtraction (DES) in direct digital radiography of chest. Methods: 83 cases of chest digital radiography(DR) using double-energy subtraction (DES) were randomly selected, and three posterior-anterior (PA) chest films (standard image, bone image and soft tissue image) were obtained in each case, which is so called 'bone and soft tissue separated' technology. Results: With the aid of double energy subtraction (DES), the bony chest was subtracted, the sensitivity and specificity of pulmonary calcification were improved, and sensitivity of pulmonary nodes was also improved, enhancing the distinction between pulmonary benign or malignant lesions, enlightening the diagnosis of chest cage lesions, and showing a clear superiority in the detection of pulmonary nodes comparing to common chest films. The double energy ...
... Science, Computer Vision, Digital Government, Digital Libraries, Digital Society and Technologies ... for Robust Intelligence, Digital Government, and Digital Libraries and Archives. In subsequent years ...
Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the cervicothoracic region, where it is usually difficult ...
AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed ...
AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed ...
Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)
A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.
In this work, a pre-cracked semi-circular shaped explosive simulant was loaded using a split Hopkinson pressure bar (SHPB). A high-speed camera was used to capture the deformation and fracture process of the specimen in situ. The digitalimages were processed using the digitalimage correlation (DIC) method. Next, full displacement and strain fields were obtained. The displacement vector field shows that the specimen fractured under tensile stress action. The strain field can be used to predict the crack propagation. Results show that the method of combined DIC and SHPB is effective to study the dynamic deformation and fracture behavior of explosive simulants. In addition, the specimen was loaded using a drop weight. The fracture toughness of the specimen was preliminary measured.
The authors propose a method for determining the risk of femoral neck fracture in osteoporotic patients that is not based on densitometric techniques. The method is based on a structural analysis performed by a computer on data taken from a single digital anteroposterior projection of the hip. From the image, the effective cross-sectional area and cross-sectional moment of inertia are computed from attenuation principles. Together with other geometric measurements, these data are used in an engineering analysis to compute the yield strength of the proximal femur, under stress applied through the acetabulum in a one-legged stance. An index of fracture risk based on the ratio of estimated yield strength to body weight is proposed. Ultimately it is expected that this work will allow the clinician to estimate hip fracture risk in osteoporotic patient using widely available existing technology, a goal which has eluded bone density-based methods.
The radionuclide X-ray fluorescence analyzer consists of a source changer and a sample changer. "5"5Fe, "1"0"9Cd and "2"4"1Am are used as excitation sources. The radiation is detected with a semiconductor Si(Li) detector. The complete assembly of the apparatus consists of an imagine unit, a keyboard, a floppy disc drive, a printer, a console and a rack with analog and digital electronics. Its multichannel amplitude analyzer consists of power supplies, a high voltage supply, a linear amplifier, an analog-to-digital converter and a computer. The technical specifications are given. The control and data processing system is controlled with an MHB 8080A microprocessor. Software for semiconductor gamma spectrometry and for quantitative gamma spectrometry will be supplied with the equipment. (E.S.). 3 figs., 4 refs.
The high incidence and mortality rates of prostate cancer have stimulated research for prevention, early diagnosis and appropriate treatment. DNA ploidy status of tumour cells is an important parameter with diagnostic and prognostic significance. In the current study, DNA ploidy analysis was performed using image cytometry technique and digitalimage processing and analysis. Tissue samples from prostate patients were stained using the Feulgen method. Images were acquired using a digitalimaging microscopy system consisting of an Olympus BX-50 microscope equipped with a color CCD camera. Segmentation of such images is not a trivial problem because of the uneven background, intensity variations within the nuclei and cell clustering. In this study specific algorithms were developed in Matlab based on the most prominent ...
Fuji Computed Radiography (FCR) utilizes imaging plates of scanning lazer stimulated luminescence. FCR can be used for intravenous digital subtraction angiography (IVDSA) and for intraarterial studies because of tis high contrast and spatial resolution. Pixel size of the imaging plates for angiography is 0.2 mm. Experimentally, it could demonstrate a vessel 1 mm in diameter with a contrast of 0.1, when opacified with a contrast medium of 3 % iodine concentration, and could image a vessel 3 mm in diameter with contrast of 0.1, when opacified with 1 % contrast medium. A 20 % stenosed portion of a vessel 3 mm in diameter was identified when opacified with 3 % contrast medium, and a 20 % stenosed portion of a vessel 2 mm in diameter was identified when opacified with 10 % contrast medium. In 105 IVDSA examinations of 75 patients, FCR was superior to Digital Fluorography (DF) in spatial ...
Fetal MRI can be performed in the second and third trimesters. During this time, the fetal brain undergoes profound structural changes. Interpretation of appropriate development might require comparison with normal age-based models. Consultation of a hard-copy atlas is limited by the inability to compare multiple ages simultaneously. To provide images of normal fetal brains from weeks 18 through 37 in a digital format that can be reviewed interactively. This will facilitate recognition of abnormal brain development. T2-W images for the atlas were obtained from fetal MR studies of normal brains scanned for other indications from 2005 to 2007. Images were oriented in standard axial, coronal and sagittal projections, with laterality established by situs. Gestational age was determined by last menstrual period, earliest US measurements and sonogram performed on the same day as the MR. The software program ...
During the past three years the program has undergone a substantial revitalization. There has been no significant change in the scientific direction of this grant, in which emphasis continues to be placed on developing new or improved methods of obtaining quantitative data from radiotracer imaging studies. However, considerable scientific progress has been made in the three areas of interest: Radiochemistry, Quantitative Methodologies, and Experimental Methods and Feasibility Studies, resulting in a sharper focus of perspective and improved integration of the overall scientific effort. Changes in Faculty and staff, including development of new collaborations, have contributed to this, as has acquisition of additional and new equipment and renovations and expansion of the core facilities. 121 refs., 30 figs., 2 tabs.
The spray and combustion development in a single-cylinder, direct-injection diesel engine equipped with optical access was examined using a number of complementary techniques. A laser imaging system, based around a pulsed copper-vapour laser synchronised to an intensified CCD camera, was used to obtain images of the four fuel sprays prior to combustion, and to determine the tip penetration of each spray as a function of crankangle. The surface heat flux to the wall of the piston bowl was measured by placing a fast-response thermocouple at the impingement point of one of the sprays, and a two-colour imaging system was used to obtain digitalimages of the flame temperature and equivalent soot distribution in the cylinder. (author)
Visualization of a liquid metal flow and image processing methods to measure the vector field are carried out by real-time neutron radiography. The JRR-3M real-time thermal neutron radiography facility in the Japan Atomic Energy Research Institute was used. Lead-bismuth eutectic was used as a working fluid. Particles made from a gold-cadmium intermetallic compound (AuCd{sub 3}) were used as the tracer for the visualization. The flow vector field was obtained by image processing methods. It was shown that the liquid metal flow vector field was obtainable by real-time neutron radiography when the attenuation of neutron rays due to the liquid metal was less than l/e and the particle size of the tracer was larger than one image element size digitized for the image processing. (orig.).
Visualization of a liquid metal flow and image processing methods to measure the vector field are carried out by real-time neutron radiography. The JRR-3M real-time thermal neutron radiography facility in the Japan Atomic Energy Research Institute was used. Lead-bismuth eutectic was used as a working fluid. Particles made from a gold-cadmium intermetallic compound (AuCd_3) were used as the tracer for the visualization. The flow vector field was obtained by image processing methods. It was shown that the liquid metal flow vector field was obtainable by real-time neutron radiography when the attenuation of neutron rays due to the liquid metal was less than l/e and the particle size of the tracer was larger than one image element size digitized for the image processing. (orig.).
Ten patients with traumatic femoral neck fracture were studied with MR imaging (0.5 T, Magnetom, Siemens): unenhanced (multiecho, TR/TE = 1,600/30--240 [repetition time/echo time, msec]; gradient echo, TR/TE = 315/14, #theta# = 90 degrees) and Gd-DTPA enhanced (0.1 mM/kg body weight, Magnevist, Schering; gradient echo, TR/TE = 315/14, #theta# = 90 degrees). MR images were compared with clinical-radiographic findings. Digital subtraction angiography of the femoral head (FH) in five patients showed complete interruption of blood supply to the FH in three patients (signal intensity of FH did not increase on postcontrast images) and intact FH arteries in two patients (FH signal increased on postcontrast images, as did the healthy-side signal).
Bit Plane Complexity Segmentation (BPCS) digital picture steganography is a technique to hide data inside an image file. BPCS achieves high embedding rates with low distortion based on the theory that noise-like regions in an image's bit-planes can be replaced with noise-like secret data without significant loss in image quality. . In this framework we will propose a collaborate approach for select frame for Hiding Data within MPEG Video Using Bit Plane Complexity Segmentation. This approach will invent high secure data hidden using select frame form MPEG Video and furthermore we will assign the well-built of the approach; during this review the author will answer the question why they used select frame steganography. In additional to the security issues we will use the digital video as a cover to the data hidden. The reason behind opt the video cover in this approach is the huge ...
A Langmuir film is a molecularly thin film on the surface of a fluid; we study the evolution of a Langmuir film with two co-existing fluid phases driven by an inter-phase line tension and damped by the viscous drag of the underlying subfluid. Experimentally, we study an 8CB Langmuir film via digitally-imaged Brewster Angle Microscopy (BAM) in a four-roll mill setup which applies a transient strain and images the response. When a compact domain is stretched by the imposed strain, it first assumes a bola shape with two tear-drop shaped reservoirs connected by a thin tether which then slowly relaxes to a circular domain which minimizes the interfacial energy of the system. We process the digitalimages of the experiment to extract the domain shapes. We then use one of these shapes as an initial condition for the numerical solution of a boundary-integral model of the underlying hydrodynamics and compare the ...
As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness.
As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness. (author).
A semiautomatic system for measurements of nuclear tracks in nuclear emulsion is described. The microscopic image of a particle track is picked up by a video camera. The video picture is digitized in real time. The picture analysis is done via software. The microscope is equipped with a stepping motor driven stage which is also computer-controlled.
Methods of solving Navier-Stokes equations for turbulent channel flow are given. These numerical solutions utilize either Neumann or Dirichlet boundary conditions. Computer codes were written and tested and are discussed. Digitalimage processing of flow visualization video sequences, taken simultaneously with vorticity probe measurements in a turbulent boundary layer, were carried out. 4 figs. (GHH)
In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digitalimage in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).
We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curve, modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ)) for Cannon's flat-panel detector (FPD), Fuji computed radiography (FCR) and screen-film (S/F) systems, respectively. First, the digital and overall characteristic curves of FPD and FCR systems were more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of FPD system were better than those of FCR system a little at lower spatial frequencies than 0.8 mm"-"1, but the overall MTF of FPD and FCR systems were worse than that of S/F system a little at all spatial frequencies. Third, the digital and overall WS of FPD system were similar or better than those of FCR system, but the overall WS of FPD and FCR systems were worse than that of S/F system. Fourth, the pre-sampling and overall ...
We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curve, modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ)) for Cannon's flat-panel detector (FPD), Fuji computed radiography (FCR) and screen-film (S/F) systems, respectively. First, the digital and overall characteristic curves of FPD and FCR systems were more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of FPD system were better than those of FCR system a little at lower spatial frequencies than 0.8 mm{sup -1}, but the overall MTF of FPD and FCR systems were worse than that of S/F system a little at all spatial frequencies. Third, the digital and overall WS of FPD system were similar or better than those of FCR system, but the overall WS of FPD and FCR systems were worse than that of S/F system. Fourth, the pre-sampling ...
Internet bandwidth is in high demand, and one way that web sites lower the amount of bandwidth they use is by compressing their site's images. This lowers the amount of bandwidth used, and makes the site load much faster. There are of course many other useful applications for compressed images. Bit Plane Complexity Segmentation (BPCS) digital picture steganography is a technique to hide data inside an image file. BPCS achieves high embedding rates with low distortion based on the theory that noise-like regions in a bit-plane can be replaced with noise-like secret data without discernible loss in image quality. This is possible because the human eye, while very good at distinguishing anomalies in areas of homogenous texture, is bad at distinguishing anomalies in visually complex areas. However, BPCS is not a robust embedding scheme, and any lossy compression usually destroys the ...
Objective: An evaluation of the application of DR in thoracic spine and a comparative study of the DR with the conventional radiography. Methods: DR images and the conventional radiogram of 89 cases respectively were evaluated by 3 vice-consultant doctors and 2 chief technicians. Statistics was processed with 2 categories: (1) images were classified into grade A, B, C and condemned according to the image quality; and (2) thoracic spine are divided into upper, middle and lower portions, in which the rate of successful imaging were compared respectively. Results: The image quality of DR: 74. 1% images in grade A, 20.2% in grade B, 5.7% in grade C, and no image condemned. Conventional radiogram: 45% images in grade A, 41.6% in grade B, 11.2% in grade C, and 2.2% images condemned. The successful ...
Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two ...
Several neutron radiography systems designed to view transient processes on a real-time basis have been developed. With the advent of these different real-time systems comes the necessity to develop a means to quantitatively evaluate and compare these systems. A suitable method for measuring the resolution capabilities of the image-forming system is the determination of the modulation transfer function (MTF). The MTF is a measure of an imaging system's ability to reproduce the spatial frequencies present in an image. The system in use at the University of Missouri Research Reactor is described. (Auth.).
The auroras on Jupiter and Saturn can be studied with a high sensitivity and resolution by the Hubble Space Telescope (HST) ultraviolet (UV) and far-ultraviolet (FUV) Space Telescope spectrograph (STIS) and Advanced Camera for Surveys (ACS) instruments. We present results of automatic detection and segmentation of Jupiter's auroral emissions as observed by HST ACS instrument with VOronoi Image SEgmentation (VOISE). VOISE is a dynamic algorithm for partitioning the underlying pixel grid of an image into regions according to a prescribed homogeneity criterion. The algorithm consists of an iterative procedure that dynamically constructs a tessellation of the image plane based on a Voronoi Diagram, until the intensity of the underlying image within each region is classified as homogeneous. The computed tessellations allow the extraction of quantitative information about the auroral ...
digital libraries, which was identified as a national challenge in the Information ... The linkages between the many digital libraries and information services are ...
The Sloan Digital Sky Survey (SDSS) started a new phase in August 2008, with new instrumentation and new surveys focused on Galactic structure and chemical evolution, measurements of the baryon oscillation feature in the clustering of galaxies and the quasar Ly{alpha} forest, and a radial velocity search for planets around {approx}8000 stars. This paper describes the first data release of SDSS-III (and the eighth counting from the beginning of the SDSS). The release includes 5-band imaging of roughly 5200 deg{sup 2} in the Southern Galactic Cap, bringing the total footprint of the SDSS imaging to 14,555 deg{sup 2}, or over a third of the Celestial Sphere. All the imaging data have been reprocessed with an improved sky-subtraction algorithm and a final, self-consistent recalibration and flat-field determination. This release also includes all data from the second phase of the Sloan Extension for Galactic ...
The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion from being reached. The fact that all ...
The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion from being reached. The fact that all ...
In order to improve the image quality of linear tomography performed with the Fuji Computed Radiography (FCR) system, we have examined one-dimensional unsharp mask filtering to reduce blur formed in the direction of tomographic swing. We determined a mask size and a weighting factor of the image processing suitable to obtain a quality tomogram. The mask size of 41 x 1 pixels for a 14 x 14'' imaging plate, which modifies the original image date and results in demonstrating a peak frequency at 0.2 cycles/mm for spatial frequency spectrum, is superior in showing fine vessel structures and morphological features of pathology in the lung fields. An additional spatial frequency filtration in the direction perpendicular to the tomographic movement reduces the blur and clearly demonstrates object contours running parallel to the tube movement. However, the additional filtration increases the ...
Thallium-201 myocardial imaging was performed in 80 children with coronary arterial lesions due to Kawasaki disease in order to assess the value of serial and exercise myocardial imagings. In eight of these children, abnormalities of the image were noted. Twenty children had serial thallium studies with an interval of three to 18 months, and five of these showed changes in the image including appearance of a new perfusion defect in one patient and improvement of perfusion defects in four. These changes of the myocardial image were correlated well with coronary angiographic findings obtained within a few days of the isotope studies. It was noted that the changes of the myocardial image were more frequently observed at relatively recent period recovered from Kawasaki disease. Exercise myocardial imaging using a bicycle ergometer was performed ...
Neutron radiography (NR) is a useful non-destructive method for determination of hydrogen content in various building and technical materials. Monitoring of transport processes of moisture and hydrogenous liquids in porous building materials is enabled by fast, quasi-real-time NR methods based on novel imaging plate neutron detectors (IP-NDs). Hydrogen content in the samples is determined by quantitative analysis of measured profiles of neutron attenuation in the samples. Detailed description of quantitative NR method is presented by the authors in another accompanying contribution at this conference. Deterioration of building materials is originated by different processes that all require presence of water therefore it is essential to limit or prevent the transport of water through the porous material. In this presentation, results of a study of clay brick impregnation by silicone based hydrophobic agents will be ...
We present a new modular traffic signs recognition system, successfully applied to both American and European speed limit signs. Our sign detection step is based only on shape-detection (rectangles or circles). This enables it to work on grayscale images, contrary to most European competitors, which eases robustness to illumination conditions (notably night operation). Speed sign candidates are classified (or rejected) by segmenting potential digits inside them (which is rather original and has several advantages), and then applying a neural digit recognition. The global detection rate is ~90% for both (standard) U.S. and E.U. speed signs, with a misclassification rate 150 minutes of video. The system processes in real-time ~20 frames/s on a standard high-end laptop.
Fuji Computed Radiography (FCR) is a new system of digital radiography that is based on the latest computer technologies. We applied this FCR system to the X-ray diagnosis of the laryngeal disease. Twenty patients with various laryngeal diseases were evaluated by both FCR frontal tomography and conventional screen-film frontal tomography under the same exposure condition. Both tomograms were then compared on the subject of the clarity of delineation of laryngeal structures. As the result, FCR tomograms revealed the feature of the laryngeal lumen and cartilages more clearly than conventional tomograms. In addition, energy subtraction method, which is one of FCR image processing systems, was presented as a new technical procedure to extinguish cervical spine shadows in plain anteroposterior laryngeal X-photograph. We stress that FCR system is the suitable procedure for X-ray analysis of laryngeal diseases, especially in the region related with ...
Results of ongoing research project at the McMaster Nuclear Reactor Facility on real-time neutron radiography for the visualization of interfacial geometry, movements and phase distributions in gas-liquid and gas-liquid-metal multi-phase flows are presented. Experiments were conducted with bubble column tubes with boiling liquid nitrogen, air-water and air-mercury mixtures. Discussions are also focused on air-water flowing within a tube containing a CANDU type 37 rod fuel bundle assembly positioned both horizontally and vertically. Computer processing using a digitalimage format to enhance the real-time images was used. Imaging techniques include frame averaging, background substraction, edge enhancement (spatial filtering), contrast enhancement and video densitometry. (orig.).
Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digitalimage processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images.
Extracting mining subsidence land from remote sensing (RS) images is one of important research contents for environment monitoring in mining area. The accuracy of traditional extracting models based on spectral features is low. In order to extract subsidence land from RS images with high accuracy, some domain knowledge should be imported and new models should be proposed. This paper, in terms of the disadvantage of traditional extracting models, imports domain knowledge from practice and experience, converts semantic knowledge into digital information, and proposes a new model for the specific task. By selecting the Luan mining area as a study area, this new model is tested based on GIS and related knowledge. The result shows that the proposed method is more precise than traditional methods and can satisfy the demands of land subsidence monitoring in mining area. 10 refs., 4 figs., 1 tab.
To evaluate the usefulness of portable chest radiographs by Fuji computed radiography (FCR) in ICU, FCR radiographs of 56 patients who were admitted to General Intensive Care Unit of Keio University Hospital were compared with the conventional portable images. Because FCR could show two differently processed images in one film and allowed a wide range of image reproduction, visualization of the trachea, bone soft tissues and catheters by FCR was easier than that by the conventional radiography. Repeated radiographs by FCR had similar optical densities and limited exposure errors. Furthermore, radiation was reduced than that of the conventional radiography. In conclusion, FCR is thought to be a useful technique for portable chest radiography in ICU patients. (author).
To evaluate the usefulness of portable chest radiographs by Fuji computed radiography (FCR) in ICU, FCR radiographs of 56 patients who were admitted to General Intensive Care Unit of Keio University Hospital were compared with the conventional portable images. Because FCR could show two differently processed images in one film and allowed a wide range of image reproduction, visualization of the trachea, bone soft tissues and catheters by FCR was easier than that by the conventional radiography. Repeated radiographs by FCR had similar optical densities and limited exposure errors. Furthermore, radiation was reduced than that of the conventional radiography. In conclusion, FCR is thought to be a useful technique for portable chest radiography in ICU patients. (author).
Computed tomography (CT) has been incorporated in an industrial Diode-Array Digital Radiography (DADR) system. An input data size of 512 pixel points x 400 projections yielded a 400x400 output image matrix. Reconstruction algorithms used are the filtered backprojection (FBP) and the direct Fourier reconstruction (DFR). Various filters were used in the FBP reconstruction process and their effects on image quality were evaluated. A spatial resolution of 100 {mu}m was measured with a block of plates and a minimum detectable feature size in the range of 10-100 {mu}m was measured using thin wires. Industrial specimens imaged have included ceramic samples, ball bearings and integrated circuits. A number of engineering problems have been solved, such as adjustment of the X-ray source, centering of the rotator spindle in the view field and beam-hardening corrections. (orig.).
Parathyroid imaging based on the principle of differential uptakes of Tc-99m and T1-201 in the anterior neck to localize parathyroid (PT) disease has been reported with widely varying results. To evaluate the usefulness of this method, we have performed PT imaging on 47 patients prior to exploratory surgery for PT disease. Using pinhole collimation and digital acquisition, a 50k count image of the thyroid was obtained 20 minutes after injection of 1mCi99m Tc-pertechnetate. Then a lmCi dose of Tl-201 chloride was injected and a series of images acquired for 30 minutes at 30 sec/image. Raw data was spatially filtered and normalized by summing sufficient T1-201 images to equal the Tc-99m image scale of maximum cts/pixel. Image subtraction (Tl-Tc) gave the final PT image. Of 10 pts ...
An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.
An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.
The need for noninvasive sensitive techniques for the diagnosis and follow-up of metabolic bone disease in dialysis patients has stimulated the author's interest in the efficacy of more detailed quantitative bone scintigraphy. Using hemodialysis to reduce elevated soft-tissue activity at scintigraphy, an attempt was made to assess the diagnostic sensitivity of quantitative bone scintigraphy as compared to qualitative bone scintigraphic, biochemical, radiographic and bone histologic studies. The second aim of these studies was to determine if one of the two major components of renal osteodystrophy is a major determinant for skeletal radiotracer uptake. The clinical observations on the efficacy and possible specificity of quantitative bone scintigraphy in the diagnosis and follow-up during treatment of renal osteodystrophy are presented briefly in this chapter. Thus, the use of scintigraphy for the routine detection and ...
Objectives Clinical PET/MR requires the use of patient positioning aids to immobilize and support patients for the duration of the combined examination. Ancillary immobilization devices contribute to overall attenuation of the PET signal, but are not detected with conventional MR sequences and, hence, are ignored in standard MR-based attenuation correction (MR-AC). We report on the quantitative effect of not accounting for the attenuation of patient positioning aids in combined PET/MR imaging. Methods We used phantom and patient data acquired with positioning aids on a PET/CT scanner (Biograph 16, HI-REZ) to mimic PET/MR imaging conditions. Reference CT-based attenuation maps were generated from measured (original) CT transmission images (origCT-AC). We also created MR-like attenuation map...
Noninvasive prediction of vertebral body strength under compressive loading condition is a valuable tool for the assessment of clinical fractures. This paper presents an effective specimen-specific approach for noninvasive prediction of human vertebral strength using a nonlinear finite element (FE) model and an image based parameter based on the quantitative computed tomography (QCT). Nine thoracolumbar vertebrae excised from three cadavers with an average age of 42 years old were used as the samples. The samples were scanned using the QCT. Then, a segmentation technique was performed on each QCT sectional image. The segmented images were then converted into three-dimensional FE models for linear and nonlinear analyses. A new material model was implemented in our nonlinear model being more...
The profusion of online digitalimages presents new challenges for image indexing. Images have always been problematic to describe and catalogue due to lack of inherent textual data and ambiguity of meaning. An alternative to time-consuming professionally-applied metadata has been sought in the form of tags, simple keywords that form a flat structure known as distributed classification, or more popularly as a folksonomy. This research aims to increase understanding of why people tag and how effective they find it for searching, using as the focus. Open-ended questionnaires were sent out to members of the photo-sharing website Flickr, with the opportunity to post comments to an online discussion space. There is also a systematic comparison between a tag-based system and a more traditional controlled vocabulary, to test out the claims made regarding the suitability of tagging for searching and browsing. ...
Brain development during the first year of life was assessed quantitatively using apparent diffusion coefficient (ADC) images constructed from diffusion-weighted MR image data. The imaging plane was coronal at the section of the pons. The cerebral peduncle, internal capsule, corona radiata, superior longitudinal fasciculus and thalamus were selected for evaluation of their ADC values. A diffusion sensitive gradient was added in the anteroposterior direction. Thus the orientation of nerve fibers in the cerebral peduncle, internal capsule and corona radiata was perpendicular to it, and that in the superior longitudinal fasciculus was parallel to it. In neonates, the cerebral peduncle and internal capsule, having been moderately myelinated at birth, showed the slowest diffusion. The corona radiata and superior longitudinal fasciculus, having been unmyelinated at birth, showed the fastest diffusion. The ...
Currently daily quality control (QC) tests for mammography systems are generally evaluated by using visual analysis phantoms, which of course means subjective measurement. In our study, however, we evaluated a novel digital phantom, the 1Shot Phantom M plus (1Shot Phantom), together with automatic analysis software dedicated for mammography systems using Fuji computed radiography (FCR). The digital phantom enables objective evaluation by providing for actual physical measurement rather than subjective visual assessment. We measured contrast to noise ratio (CNR), image receptor homogeneity, missed tissue at chest wall side, modulation transfer function (MTF), and geometric distortion utilizing the 1Shot Phantom. We then compared the values obtained using the 1Shot Phantom with values obtained from the European guidelines and International Electrotechnical Commission (IEC) standards. In addition, we evaluated the convenience ...
Currently, x-ray mammography is the method of choice in breast cancer screening programmes. As the mammography technology moves from 2D imaging modalities to 3D, conventional computational phantoms do not have sufficient detail to support the studies of these advanced imaging systems. Studies of these 3D imaging systems call for a realistic and sophisticated computational model of the breast. DeBRa (Detailed Breast model for Radiological studies) is the most advanced, detailed, 3D computational model of the breast developed recently for breast imaging studies. A DeBRa phantom can be constructed to model a compressed breast, as in film/screen, digital mammography and digital breast tomosynthesis studies, or a non-compressed breast as in positron emission mammography and breast CT studies. Both the cranial-caudal and mediolateral oblique views can be modelled. The ...
Purpose: To report our clinical experiences with on-board imager (OBI) kV image verification for cranial stereotactic radiosurgery (SRS) and radiotherapy (SRT) treatments. Methods and Materials: Between January 2007 and May 2008, 42 patients (57 lesions) were treated with SRS with head frame immobilization and 13 patients (14 lesions) were treated with SRT with face mask immobilization at our institution. No margin was added to the gross tumor for SRS patients, and a 3-mm three-dimensional margin was added to the gross tumor to create the planning target volume for SRT patients. After localizing the patient with stereotactic target positioner (TaPo), orthogonal kV images using OBI were taken and fused to planning digital reconstructed radiographs. Suggested couch shifts in vertical, longitudinal, and lateral directions were recorded. kV images were also taken immediately after ...
By characterising the microstructure, quantitativeimage analysis allows to draw conclusions on the mechanical properties of materials. On fine microstructures with low contrast, e.g. of hardened steels, texture analysis has to be applied for quantification. Feeding texture parameters according to Haralick into a trained neural network, a correlation between the microstructure and the hardness of the steels C45 and 100Cr6 can be achieved. (orig.)
Seeing convolved two-dimensional de Vaucouleurs profiles have been fitted to digitalimages of the brightest elliptical galaxies in two nearby groups of galaxies and three clusters of galaxies with redshifts in the range 0.06 to 0.15. The digitalimages were created by scanning electronographic plates obtained by the use of several versions of the RGO electronographic camera. The linear relation between effective surface brightness #mu#/sub e/ and the logarithm of the effective radius r/sub e/, first discovered by Kormendy to be valid for nearby elliptical galaxies, is found to be equally valid for the largest and brightest galaxies in rich clusters of galaxies. The apparent universal nature of that relation indicates that the same type of processes might have been involved during the formation of all ellipticals from cD galaxies in clusters to fainter ellipticals in small groups. It is suggested that ...
A computer-aided detection (CAD) system was evaluated for its ability to detect microcalcifications and masses on images obtained with a digital phase-contrast mammography (PCM) system, a system characterised by the sharp images provided by phase contrast and by the high resolution of 25-{mu}m-pixel mammograms. Fifty abnormal and 50 normal mammograms were collected from about 3,500 mammograms and printed on film for reading on a light box. Seven qualified radiologists participated in an observer study based on receiver operating characteristic (ROC) analysis. The average of the areas under ROC curve (AUC) values for the ROC analysis with and without CAD were 0.927 and 0.897 respectively (P = 0.015). The AUC values improved from 0.840 to 0.888 for microcalcifications (P = 0.034) and from 0.947 to 0.962 for masses (P = 0.025) respectively. The application of CAD to the PCM system is a promising approach for the detection of ...
The airborne traffic monitoring system forms a novel technology of detecting vehicle motion. An optical digital camera located on an airborne platform produces a series of images which then are processed to recognized the fixed vehicles. In this way the video data are converted into the time sequence of frames containing the vehicle coordinates. In the present work a three-frame algorithm is developed to identify the succeeding vehicle positions. It is based on finding the neighboring points in the frame sequence characterized by minimal acceleration. To verify and optimize the developed algorithm a ``Virtual Road'' simulator was created. Finally available empirical data are analyzed using the created algorithm.
Until April 2007 the Major Atmospheric Gamma ray Imaging Cherenkov (MAGIC) telescope used a 300 MSamples/s flash analog-to-digital converter (FADC) system to sample the shaped photomultiplier tube (PMT) signals produced by the captured Cherenkov photons of air showers. Different algorithms to reconstruct the signal from the read-out samples (extractors) have been implemented and are described and compared. Criteria based on the obtained charge and time resolution/bias are defined and used to judge the different extractors, by applying them to calibration, cosmic and pedestal signals. The achievable charge and time resolution have been derived as functions of the number of incident photo-electrons.
In dual-energy projection radiography with double exposures, rapid energy switching is mandatory to eliminate motion artifacts, but it is costly for use in a clinical environment. We developed a system with practical exposure intervals at reasonable cost by modifying a condenser-type X-ray generator. A commercially available system for digital radiography (Fuji Computed Radiography, FCR) was used to subtract images. This report dealt with technical factors to obtain adequate kV and mAs settings in this technique.
In dual-energy projection radiography with double exposures, rapid energy switching is mandatory to eliminate motion artifacts, but it is costly for use in a clinical environment. We developed a system with practical exposure intervals at reasonable cost by modifying a condenser-type X-ray generator. A commercially available system for digital radiography (Fuji Computed Radiography, FCR) was used to subtract images. This report dealt with technical factors to obtain adequate kV and mAs settings in this technique. (author).
Conformal radiation therapy represents a considerable and attractive challenge in oncology. Its aim is mainly to improve local control by increasing the dose with an acceptable rate of complications. This work overviews the world literature on this subject. The technical and theoretical requirements are highlighted. These requirements include a precise definition of the target volume by digitalimaging (essentially CT scan), but also clear view of the target volume and the organs at risk, a specific collimation of the beam, 3-D dose calculations, optimization procedures, and a rigid immobilization of the patient with verification of his position. Moreover, the clinical applications of conformal radiation therapy are reviewed and discussed. (authors). 80 refs., 1 tab.
Rapid and reliable transmission of nuclear medicine studies using conventional telephone lines and commercially available modems and computer systems has been accomplished through use of software developed within the authors' hospital. Original digitalimages of all-night and weekend studies, acquired on any of the acquisition computers from different manufacturers, are now routinely sent for remote reading at the physician's home. Data, software, and letters are routinely exchanged using modems and standard telephone lines with a sister institution in Haifa, Israel. The software has been designed to achieve no loss data compression and minimal turnaround time loss. Thus, an average lung perfusion image or gallbladder study requires about 1-3 minutes of transmission time. Full analysis and display software is available on the remote computer.
Mentougou District acts as a crucial component in the ecological buffer in western Beijing mountainous areas, Beijing, China. Using two Landsat MSS/TM images acquired on July 14, 1979 and July 23, 2005, the vegetation coverage of Mentougou District was calculated based on normalized difference vegetation index and spectral mixture analysis (NDVI-SMA) model. Its temporal and spatial changes were analyzed according to digital elevation model (DEM) image, social and economic data. The results showed that the vegetation coverage decreased from 76.4% in 1979 to 72.7% in 2005. Vegetation degradation was probably the result of human disturbance, such as outspreading of resident areas, and coal and stone mining activities, while vegetation restoration might be contributed by the combined effects o...
Terrain attributes derived from digital elevation models have been used widely for mapping soil organic matter (SOM). Among these attributes, the topographic wetness index (TWI), an index for quantitatively indicating the balance between water accumulation and drainage conditions at the local scale, has been shown to correlate with SOM. However, TWIs used in most studies are calculated using a single-flow-direction (SFD) algorithm, which assumes that all water from a grid cell flows into only one neighboring cell. This assumption is not always valid, especially in areas with low relief where movement of water may be divergent. To overcome this SFD limitation, a multiple-flow-direction (MFD) algorithm has been developed, which distributes flow from a grid cell to several downslope neighbors...
Objective: To explore the feasibility of real-time monitoring exposure dose and image quality by using the data stored in the DICOM image archive of direct digital radiography system. Methods: Model TO. 16 was exposed, the current increased gradually from 0.5 to 125 mAs. The displayed number of model A( diameter 11.1 mm), D (diameter 4.0 mm) and J( diameter 0.7 mm) were recorded, and the detect factors (H_T) was also calculated. Images were sent to workstation before the end of DR examination. An automatic procedure was implemented to extract dose data and exposure parameters from the DICOM header file. Maximum, minimum and 3rd quartile values were preinstalled. Mean values exceeding the threshold trigger alarm signal to guide radiologist to explore the cause. Results: When the current of point A was less than 10 mAs and the current of point D and J were less than 16 mAs, the detect factor (H_T) ...
Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are ...
A vessel phantom suitable for evaluation of spatial and contrast resolution of FCRDSA (Fuji Computed Radiography, digital subtraction angiography) has been developed and used for determining resolution. The effects of iodine concentration, low dose exposure, and acryl thickness on the resolution were evaluated in FCRDSA, and FCRDSA images were compared with film substraction with use of this phantom. It has been proven that limitation of resolution of FCRDSA was 5 % 1 mm and about 1/4 dose exposure compared with conventional film exposure was clinically acceptable. Dye dilution method was useful to determine a program of IVDSA with imaging plate. It has been proven that time to appearance and time to peak of time-concentration curve of dye dilution method closely correlate to time to appropriate image of DSA in the neck, the chest, and the abdomen. 106 cases of IVDSA and 130 cases of IADSA using FCR in ...
A real-time neutron radiography system was installed at the neutron radiography facility of Sumitomo Heavy Industries where a sub-compact cyclotron is used as a neutron generator and nominal neutron flux was observed as 1.1 x 10"6 n/cm"2/sec. Preliminary tests were made for various kinds of such components as collimators, scintillators, cameras and lenses and the system was chosen to give the highest quality images. Especially for the scintillator screen, screening tests were carried out for compounds of LiF/ZnS(Ag) and Gd_2O_3/ZnS(Ag) by radiographic film method. The neutron radiography image was converted to fluorescent images by means of the converter and observed by a SIT type TV camera. The video signal was directly displayed on a CRT or after processed with digitalimage processing devices. The characteristics of this system as for the resultant resolution are presented ...
In neutron radiography, as in other forms of NDE, it is sometimes desirable to observe dynamic events. This need has generated increased interest in real-time neutron radiography systems. As in other forms of radiography, a standard method for measuring the image forming capability of real-time systems is necessary in order to compare the various methods and systems used. A technique which has been used extensively in general photography and has been applied in the characterization of several screen-film combinations used in conventional neutron radiography is to determine the imaging system's modulation transfer function (MTF). This gives a graphical representation of the system's spatial resolution capabilities and was therefore chosen as the method for evaluation of the real-time neutron radiography facility at the University of Missouri Research Reactor (MURR). The method used was to image a knife-edge, differentiate ...
This paper proposes a new pattern recognition system employing optical joint transform correlation (JTC) technique which offers a great number of advantages over similar digital techniques, including very fast operation, simple architecture and capability of updating the reference image in real time. The proposed JTC technique incorporates a synthetic discriminant function (SDF) of the target image estimated from different training images to make the pattern recognition performance invariant to noise and distortion. It then involves four different phase-shifted versions of the same target SDF reference image, which are individually joint transform correlated with the given input scene. When the correlation signals are combined, it produces a single cross-correlation peak corresponding to each potential target present in the given input scene. The proposed technique also includes a ...
Quantitative structure activity relationship (QSAR) analysis of the correlations between initial brain uptake and structure parameters, for example lipophilicity F_r, molar refractivity MR and electronic parameters #sigma#_1 of the "9"9Tc"m-N_2S_2 complexes have been studied with multiple regression analysis method. The main structural factors which affect the initial brain uptake of this kind of brain imaging agents have been discussed. The results may give some theoretical information for designing new brain imaging agents
Abstract Copper(II) bis(thiosemicarbazone) are very useful for blood flow and hypoxic imaging. The aim of this study was to identify structure-activity relationships (SARs) within a series of analogues with different substitution patterns in the ligands, in order to design improved hypoxia imaging agents and elucidate hypoxia selectivity mechanisms. Genetic algorithms (GAs) were used to develop specific copper metal-ligand force field parameters for the MM3 force-field calculations. These new parameters produced results in good agreement with experiment and previously reported copper metal-ligand parameters. A successful quantitative SAR (QSAR) for predicting the several classes of Cu(II)-chelating ligands was built using a training set of 21 Cu(II) complexes. The QSAR exhibited a correlat...
Quantitative bone scintigraphy was performed on 23 white females with post-menopausal osteoporosis and vertebral compression fractures. These patients were then entered into a randomized, double-blind clinical trial or sodium fluoride therapy (NaF=14, placebo=9) which included repeat bone scintigraphy every six months. Scintigraphic images were acquired for 500K counts per image over the total body with computer acquisition over the posterior thoracic and lumbar spine. Images were obtained on a wide field-of-view gamma camera two hours after injecting 15 mCi of Tc-99m MDP. Data analysis showed a significant reduction in the activity ratio of abnormal vertebral body to normal vertebral body in those patients treated with sodium fluoride (paired t-test p=0.0095). No significant change was observed in the control group of (p=0.142). These results suggest that sodium fluoride therapy promotes more rapid ...
(USGS Text) Digital line graph (DLG) data are digital representations of cartographic information. DLGs of map features are converted to digital form from ... ...
Satellite imagery is a cost-effective tool for creating and updating basemaps of coastal zones, especially where existing maps and aerial photographs are unavailable, are out-of-date, or provide limited information. Reliable maps of coastal zones are particularly important for oil spill modelling programs. Color IR (multispectral) images with 20m x 20m ground resolution and black & white (panchromatic) images with 10m x 10m ground resolution of many coastlines around the globe have been acquired from 1986 to present by SPOT Image Corporation. We have digitally merged same-day SPOT panchromatic and multispectral imagery to provide maximum spatial resolution and permit excellent color differentiation of coastal zone features. This combination adequately discriminates individual features, including pipelines, offshore platforms, storage tanks, jetties, and shoreline type. The SPOT ...
The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the {gamma}-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10{sup 6}n/cm{sup 2}s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/{gamma} ratio {approx} 10{sup 6}n/cm{sup 2}mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame ...
The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the #gamma#-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10"6n/cm"2s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/#gamma# ratio #approx# 10"6n/cm"2mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame grabber and a ...
In this paper we present the results of time series analysis for a coal mining region based on partial unmixing. We test the method also known as mixture tuned matched filtering on an eight image Landsat 5 TM and Landsat 7 ETM+ time series covering the period from 1987 to 2003. Common change detection methods often include the comparison of two interactively generated classification results, such as derived from Maximum Likelihood classification. These approaches often yield highly accurate results. However, disadvantages include a strong analyst bias and hardly repeatable results. For a quantitative monitoring of a single surface class' development over time they are often not recommendable. Our goal was to test an unbiased quantitative way to assess the development of coal surfaces, such...
Present day mammography has not been able to make use of the advantages of digital luminescence radiography because of the limited spatial resolution. The recent development of electromagnetic focusing X-ray tube with effective focal spot sizes from 0.04 to 0.12 mm allows radiographic direct magnification with less geometric blur. It is now possible to combine direct magnification mammography with digital luminescence radiography. By combining high quality storage phosphor screens with an HQ-workstation a spatial resolution of 8 lp/mm is possible for 1.7-fold magnification. For 4-fold spot magnification views spatial resolution can be theoretically increased to approx. 20 lp/mm. One important advantage of digital radiography is the possibility of image-postprocessing. This article presents two sets of standard parameters and three sets of image dependent parameters for better ...
The image quality of digital luminescent radiography (DLR) is sufficient for routine biplane chest radiography and for follow-up studies of heart size, pulmonary congestion, coin lesions, infiltrations, atelectasis, pleural effusions, and mediastinal and hilar lymph node enlargement. Chest radiography in the intensive care unit may in most cases be performed using the DLR technique. there is no need for repeat shots because of incorrect exposure, and the position of catheters, tubes, pacemakers, drains and artificial heart valves, the mediastinum, and the retrocardiac areas of the left lung are more confidently assessed on the edge-enhanced DLR films than on conventional films. Nevertheless, DLR is somewhat inferior to conventional film-screen radiography of the chest as it can demonstrate or rule out subtle pulmonary interstitial disease less confidently. There is no reduction of radiation exposure of the chest in DLR compared with modern ...
As compared with terrestrial circuits, the communication satellite possesses superior characteristics such as wide area coverage, broadcasting, high capacity, and robustness to disasters. Utilizing the narrow band channel (64 kbps) of the geostationary satellite JCSAT 1 located at the altitude of 36,000 km above the equator, the authors investigated satellite-relayed medical imagings by video signals, with bone scintigraphy as a model. Each bone scintigraphy was taken by a handy-video camera, digitalized and transmitted from faculty of technology located at 25 kilometers apart from our department. Clear bone scintigraphy was obtained via satellite, as seen on the view box. Eight nuclear physicians evaluated 20 cases of bone scintigraphy. ROC (Receiver Operating Characteristic) analysis was performed between the scintigraphies on view box and via satellite by the rating method. The area under the ROC curve was 91.6#+-#2.6% via satellite, and ...
Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was evaluated by 19 radiologists, using ROC ...
Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was evaluated by 19 radiologists, using ROC ...
This research aims at elucidating thermal hydraulic phenomena by carrying out their visualization and measurement which are difficult by conventional method, utilizing the excellent properties of real time neutron radiography and showing the usefulness of neutron radiography. The experiments were carried out on the visualization and measurement of liquid metal flow and mixed phase flow and the visualization and diagnosis of mixed phase flow equipment. As the achievement in this fiscal year, the image-processing method for visualizing quantitatively the distribution of void fraction in gas-liquid two-phase flow has been devised, therefore, its method and results are reported. For the analysis of multi-dimensional two-phase flow, in order to prepare the model and determine the constitution equation, the data on the multi-dimensional distribution of void fraction are required. Void fraction is defined. The method of image ...
Quantitative gated SPECT (QGS) was evaluated in 7 normal volunteers and 31 patients with cardiac diseases. Adequate cut off value of a prefilter was 0.45. In phantom, the left ventricular volume value was 93.9% of determined value by 180-degree projection in L type and 98.8% by 360-degree projection in opposed type. In normal volunteers, LVEF measured by QGS program related to value by first pass method. As for functional map, regional EF and wall motion decreased at the septum side, and wall thickening at base side of heart. Good correlation was recognized (p<0.0001) between blood flow image and functional map (regional EF and wall thickening). In 20 cases of acute myocardial infarction, lesion was detected conspicuously in regional EF and wall motion. The accuracy of coronary arterial stenosis improved in functional map (regional EF 92%, wall motion 92% and wall thickening 88%). In particular, the accuracy of 3 rami lesion was 100% in ...
We developed a new breast surface coil for the supine position. The subjects consisted of 9 patients with breast cancer varying from 46 to 60 years of age (average: 52). The cancer image of the SPGR (CE+) method was compared with that of the FSMTC (MTC-SPGR (CE+)) method and that of the FSMTC (MTC-SPGR with fat-saturation (CE+)) method in the sagittal section after injection of Gd-DTPA (0.1 mmol/kg). Quantitative analyses were performed before and after injection of Gd-DTPA in 6 patients. Three patients were excluded from the quantitative analyses owing to the clear detection of tumors in the fat tissue. Signal intensity measurements were systematically performed in each region of interest (ROI), i.e. the cancer lesion, the surrounding mammary gland. Statistical analyses showed significant differences between the lesions using the FSMTC (MTC-SPGR (CE+)), and the FSMTC (MTC-SPGR with fat-saturation (CE+)) methods and the ...
In the search for new brain imaging agents for use with single photon emission computed tomography (SPECT), quantitative structure activity relationship (QSAR) analysis of the correlations between initial brain uptake and physicochemical parameters like lipophilicity, log P, molecular weight, log MW and log U/D (undissociated/dissociated), of the {sup 99m}Tc-DADT (diaminedithiol) complexes and {sup 99m}Tc-PAO (propyleneaminoxime) complexes have been analyzed. High correlations are found for both the {sup 99m}Tc-DADT complexes (r = 0.94) and for the {sup 99m}Tc-PAO complexes (r = 0.83) which are significant at 99.9 and 99.5 percentile level, respectively. These results will help the further design of better ligands for {sup 99m}Tc in brain imaging. (author).
To evaluate the diagnostic performance of commercially available CRT monitors used in a teleradiology system by determining the rate of detection of simulated lung nodules. Three types of CRT monitors were tested in the observation study. They had matrix sizes of 1024 x 768 (16 inches, color), 1024 x 768 (20 inches, color) and 1600 x 1125 (24 inches, black and white). Twenty chest radiographs were obtained by Fuji computed radiography (FCR) of an anthropomorphic chest phantom with ten simulated nodules on its surface. These FCR films were digitized by a film digitizer with 125 DPI (1024 x 1024 matrix sizes) and 12 bit gray scales, and the image data were transferred from Shinshu University Hospital to other hospitals where interpretation was carried out by the radiologists. Ten radiologists of three hospitals were asked to interpret independently both the original FCR films and the images shown on the ...
We have demonstrated that optical images can be stored in transparent lead-lanthanum-zirconate-titanate (PLZT) ceramics by exposure to near-UV light with photon energies greater than the band gap energy of approx. equal to 3.35 eV. The image storage process relies on optically induced changes in the switching properties of ferroelectric domains (photoferroelectric effect). Stored images are nonvolatile but can be erased by uniform UV illumination and simultaneous application of an electric field. Although high quality images, with contrast variations of >= 100:1 and spatial resolution of approx. equal to 10 #mu#m, can be stored using the photoferroelectric effect, relatively high exposure energies (approx. equal to 100 mJ/cm"2) are required to store these images. This large exposure energy severely limits the range of possible applications of nonvolatile ...
The authors have performed I-123 IMP single- photon emission CT (SPECT) brain imaging on seven mildly demented patients with acquired immunodeficiency syndrome (AIDS) and on seven normal subjects. Pixel-intensity histograms have been analyzed for the fraction of pixels in the lowest quartile of the intensity range. This fraction (F) averaged 17.7% (standard deviation [SD] = 4.3) in the AIDS group and 12.6 (SD = 4.7) in the normal group (P <.05). Regression analysis of neuropsychological testing (NPT) scores vs F yielded a correlation coefficient of.71. The presence or degree of atrophy did not correlate with F or NPT scores.
To understand dynamic developmental processes, living tissues must be imaged frequently and for extended periods of time. Root development is extensively studied at cellular resolution to understand basic mechanisms underlying pattern formation and maintenance in plants. Unfortunately, ensuring continuous specimen access, while preserving physiological conditions and preventing photo-damage, poses major barriers to measurements of cellular dynamics in indeterminately growing organs such as plant roots. We present a system that integrates optical sectioning through light sheet fluorescence microscopy with hydroponic culture that enables us to image at cellular resolution a vertically growing Arabidopsis root every few minutes and for several consecutive days. We describe novel automated routines to track the root tip as it grows, track cellular nuclei and identify cell divisions. We demonstrate the system's capabilities by collecting data on ...
In 15 patients (16 hip joints) we found the clinical and radiological signs of BMOS. On T1-weighted MRI images areas of low signal intensity could be observed in the head, neck and the intertrochanteric region of the femur in various extensions. These areas showed a significant increase in signal intensity on the T2-weighted images. Because pain was resistant to conservative therapy all these patients were treated by core decompression of the femoral head in a prospective study. Bone cores were evaluated histologically using undecalcified sections and quantitative microradiography. The existence of intramedullary oedema in exactly the regions exhibiting the MRI pattern of bone marrow oedema was verified histologically; however, bone and marrow changes similar to those of early avascular necrosis (AVN) were also visible. (orig.)
Twenty-six patients with late complications following femoral neck fracture were examined with both skeletal and bone marrow radionuclide scintimetry. There was no correlation between the methods with respect to the quantitative assessment of femoral head vascularity based on different uptake ratios comparing the fractured and the intact side. Skeletal scintimetry always had good image quality and permitted reliable differentation between nonunion of the fracture and late segmental collapse, in contrast to bone marrow scintimetry which gave poor image quality. Skeletal scintimetry thus seems superior to bone marrow scintimetry for assessment and differential diagnosis of late complications following femoral neck fracture. It is emphasized that the physiological mechanisms for radionuclide uptake must be taken into account when comparing scintimetric studies using different tracers.
Twenty-six patients with late complications following femoral neck fracture were examined with both skeletal and bone marrow radionuclide scintimetry. There was no correlation between the methods with respect to the quantitative assessment of femoral head vascularity based on different uptake ratios comparing the fractured and the intact side. Skeletal scintimetry always had good image quality and permitted reliable differentation between nonunion of the fracture and late segmental collapse, in contrast to bone marrow scintimetry which gave poor image quality. Skeletal scintimetry thus seems superior to bone marrow scintimetry for assessment and differential diagnosis of late complications following femoral neck fracture. It is emphasized that the physiological mechanisms for radionuclide uptake must be taken into account when comparing scintimetric studies using different tracers. (author).
A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are used in place of the ...
A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are used in place of the ...
Positron emission tomography (PET) is a fully quantitative technology for imaging metabolic pathways and dynamic processes in vivo. Attenuation correction of raw PET data is a prerequisite for quantification and is typically based on separate transmission measurements. In PET/CT attenuation correction, however, is performed routinely based on the available CT transmission data. Recently, combined PET/magnetic resonance (MR) has been proposed as a viable alternative to PET/CT. Current concepts of PET/MRI do not include CT-like transmission sources and, therefore, alternative methods of PET attenuation correction must be found. This article reviews existing approaches to MR-based attenuation correction (MR-AC). Most groups have proposed MR-AC algorithms for brain PET studies and more recently also for torso PET/MR imaging. Most MR-AC strategies require the use of complementary MR and transmission images, ...
Early white matter (WM) injury affects brain maturation in preterm infants as revealed by diffusion tensor imaging and volumetric magnetic resonance (MR) imaging at term postmenstrual age (PMA). The aim of the study was to assess quantitatively brain maturation in preterm infants with and without milder forms of WM damage (punctate WM lesions, PWML) using conventional MRI. Brain development was quantitatively assessed using a previously validated scoring system (total maturation score, TMS) which utilizes four parameters (progressive myelination and cortical infolding, progressive involution of glial cell migration bands and germinal matrix tissue). PWML were defined as foci of increased signal on T1-weighted images and decreased signal on T2-weighted images with no evidence of cystic degeneration. A group of 22 preterm infants with PWML at term PMA (PWML group) ...
The authors compared unenhanced and contrast-enhanced fast MRI and Computerized Tomography in the detection of liver metastases. Eleven patients with single or multiple hepatic lesions (42 in all) were submitted to V and magnetic resonance studies; T1- and T2- weighted TSE, T2-weighted TSE with fat suppression, unenhanced breath-hold TFE and early or delayed enhanced breath-hold TFE images were acquired with a 1.5 T superconductive magnet (Philips NT). The quantitative analysis of all magnetic resonance images was performed for contrast/noise ratio (CNR) and number of detected lesions; magnetic resonance and Computerized Tomography images were also compared qualitatively for lesion conspicuity, anatomical structure identification and artifacts. The results were compared with Student's test. Early enhanced breath-hold TFE was statistically superior to T1-weighted TSE (p = .0009), T2-weighted TSE (p = ...
The aim of this study was to qualitatively and quantitatively study MR artifacts of various stents on the basis of in vitro experiments. We were particularly interested whether sequence type and orientation of the stent with respect to the static magnetic field influences the artifact. We examined 18 stents of different material (nitinol, stainless steel, cobalt alloy), different design of the stent meshes (AccuLink, OmniLink, DynaLink, Xact, Protoge, Wallstent Monorail), different diameter (5-10 mm) and different length (18-58 mm) with a turbo spin echo (TSE), a 2D-fast low angle shot (FLASH) and a 3D-FLASH sequence. The MR images were examined qualitatively with respect to possible artifacts. Furthermore we examined the MR data quantitatively: The contrast-noise-ratio (CNR) was determined both within the stent and outside (within the tube); based on these values we calculated the transparency factor P, furthermore we ...
The refrigerant two-phase flows in a distributor and a simulated plate heat exchanger with a single passage used in a compression-type refrigerator were visualized by real-time neutron radiography. For a distributor, the liquid fraction in the each tube was measured by some image processing method. On the other hand, for a plate heat exchanger, the two-dimensional distribution of void fraction was measured quantitatively by the umbra method. As a result, it was shown that the dynamic behaviors of refrigerant at the inlet of the section strongly affected on the performance, that is, a distribution performance of a distributor and a liquid distribution in a plate heat exchanger. (author)
An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.
The addition of carbon to samples, during imaging, presents a barrier to accurate TEM analysis, the controlled deposition of hydrocarbons by a focused electron beam can be a useful technique for local nanometer-scale sculpting of material. Here we use hydrocarbon deposition to form nanopores from larger focused ion beam (FIB) holes in silicon nitride membranes. Using this method, we close 100-200nm diameter holes to diameters of 10nm and below, with deposition rates of 0.6nm per minute. I-V characteristics of electrolytic flow through these nanopores agree quantitatively with a one dimensional model at all examined salt concentrations.
The simulation of processes in engineering and the physical sciences has progressed rapidly over the last several years. With rapid developments in supercomputers, parallel processing, numerical algorithms and software, scientists and engineers are now positioned to quantitatively simulate systems requiring many billions of arithmetic operations. The need to understand and assimilate such massive amounts of data has been a driving force in the development of both hardware and software to create visual representations of the underling physical systems. In this paper, and the accompanying videotape, the evolution and development of the visualization process in scientific computing will be reviewed. Specific applications and associated imaging hardware and software technology illustrate both the computational needs and the evolving trends. 6 refs.
This study evaluated surface characteristics and overlaying properties of wood plastic composite (WPC) panels made from dry-blended rubber wood fiber-polypropylene (PP) powder formulations using a conventional flat-press process under laboratory conditions. Three levels of rubberwood fibers (Hevea brasiliensis), 40%, 50%, and 60%, based on the composition by weight, were mixed with the PP powder without and with 3% (based on weight) maleic anhydride grafted PP (MAPP) as a coupling agent. Contact angle measurements on the WPC samples were performed using a goniometer connected with a digital camera which collected one image per second. Roughness measurements, average roughness (R a), mean peak-to-valley height (R z), and maximum roughness (R y), were taken from the sanded samples along and ...
An effective rehabilitation strategy is proposed to enhance the strength and stiffness of the beam-column joint in this study. An analytical model is proposed to predict the column shear of the joints strengthened with carbon fiber reinforced polymer (CFRP). Three full scale interior beam-column joints, including two specimens strengthened with CFRP and one prototype specimen, are tested in this study. The specimens are designed to represent the pre-seismic code design construction in which there is no transverse reinforcement. A new optical non-contact technique, digitalimage correlation (DIC), which can measure the full strain field of specimen, is used to measure and observe the full strain field of the joint. The experimental results show that the beam-column joints strengthened with ...
The development of calcium sulfate dihydrate (gypsum) mineral scale in reverse osmosis (RO) membrane desalting was investigated by direct real-time observation of crystal growth. Gypsum scaling studies were conducted in a specially modified plate-and-frame reverse osmosis cell fitted with an optical window, with dark-field membrane lighting arrangement within the membrane cell to enhance crystal boundaries and allow recording of digital surface images magnified through an optical microscope. The evolution of the surface number density (SND) of gypsum crystals resembled a sigmoidal population growth process with an increasing rate of crystal formation at higher solution supersaturation (with respect to gypsum) at the membrane surface. The rate of formation of new crystals declined as the su...
ABSTRACT Crack tip opening angle (CTOA) is becoming one of the most accepted methods for characterizing fully plastic fracture. It provides a measure of the resistance to fracture for a material in cases where there is a large degree of stable-tearing crack extension during the fracture process. Our current pipeline research uses the CTOA test as an alternative, or addition, to the CTOD (crack tip opening displacement) and the fracture energy characterization provided by the J-integral approach. A test technique was developed for measurement of CTOA that uses a modified double cantilever beam (MDCB) specimen. A digital camera and image analysis software were used to record the progression of the crack tip and to estimate the CTOA. In this article, CTOA data on crack growth orientations per...
This paper reports, to complement current knowledge on brain development, late regional brain maturation assessed with quantitative MR imaging. Axial and coronal head spin-echo (SE) images were obtained in 60 healthy individuals aged 5--56 years, with a double-echo, flow compensated imaging sequence obtained with a 1.5-T Magnetom spectroscopy and imaging system. T2-weighted images were calculated from the intensity differences in SE images at echo times (TEs) of 15 and 90 msec (TR = 2.5 second). The mean T2 values were determined at 16 sites in each cerebral hemisphere. T2 values of the six frontal subcortical white matter (FSCWM) sites and of the internal capsule (IC) were evaluated. Mean T2 values in the IC decreased until age 10 years, whereas this decrease continued in the FSCWM past age 15 years before reaching a plateau. Differential ...
Optional multiple long-axial gated blood pool SPECT images were prepared for the purpose of stereoscopic and quantitativeimaging of left ventricular wall motion (LVWM). Sixteen patients with ischemic heart disease and 8 healthy subjects were imaged in 32 views in the 360 degrees position after iv injection of 740 MBq of Tc-99m-labeled human serum albumin D. The R-R interval was divided into 16. After preparing conventional oblique images, long-axial images were prepared. Shortening rate of left ventricular wall was calculated in 5 segments of the apex and base of the left ventricle. An average shortening rate in each segment was graded with a score from a minimum of 0 to a maximum of 40% or more. In the normal group, shortening rate in each segment, except for the base of the septal region, exceeded 40%. In the group of ischemic heart disease, radial shortening ...
The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film arteriogram even with a ...
The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film arteriogram even with a ...
Digital audio sampling is explained, and some of its implications in digital sound applications are discussed. Digital sound equipment is rapidly replacing analog recording devices as the state-of-the-art in audio technology. The philosophy of digital recording involves doing away with the continuously variable analog waveforms and turning the patterns into numbers. A digital recording device rapidly samples the incoming sounds, quantifying the signal into a series of numerical values (binary codes). Although digital sound eliminates many of the traditional analog problems, digital signal processing presents key problems in sampling rates and synchronization. Careful control is necessary to check signals through each step in the audio chain. The advantages of digital audio processing include increased signal-to-noise ...
Studying the structure of nanoparticles as a function of their size requires a correlation between the image and the diffraction pattern of single nanoparticles. Nanobeam diffraction technique is generally used but requires long and tedious TEM investigations, particularly when nanoparticles are randomly oriented on an amorphous substrate. We bring a new development to this structural study by controlling the nanoprobe of the Bright and Dark Field STEM (BF/DF STEM) modes of the TEM. The particularity of our experiment is to make the STEM nanoprobe parallel (probe size 1 nm and convergence angle <1 mrad) using a fine tuning of the focal lengths of the microscope illumination lenses. The accurate control of the beam position offered by this technique allowed us to obtain diffraction patterns of many single nanoparticles selected in the digital STEM image. By means of this technique, we demonstrate size effects on the ...
Studying the structure of nanoparticles as a function of their size requires a correlation between the image and the diffraction pattern of single nanoparticles. Nanobeam diffraction technique is generally used but requires long and tedious TEM investigations, particularly when nanoparticles are randomly oriented on an amorphous substrate. We bring a new development to this structural study by controlling the nanoprobe of the Bright and Dark Field STEM (BF/DF STEM) modes of the TEM. The particularity of our experiment is to make the STEM nanoprobe parallel (probe size 1 nm and convergence angle <1 mrad) using a fine tuning of the focal lengths of the microscope illumination lenses. The accurate control of the beam position offered by this technique allowed us to obtain diffraction patterns of many single nanoparticles selected in the digital STEM image. By means of this technique, we demonstrate size effects on the ...
Fabrication of diffused titanium optical guides on a LiNbO/sub 3/ crystal substrate requires precise quality assurance. Light couplers in particular must be positioned within micron specifications. This requirement is the reason that the width of lines detected during microscopic inspection of the crystal is such an important parameter for quality evaluation. To assist in the inspection of these optical guides, a line width estimation program has been developed for an IBM PC based microscope inspection system. A digitalimage processing approach is used to develop an algorithm which can be tailored by the user for specific signal and noise characteristics. Default filter parameters, which can be updated and saved interactively by the user, are stored in a file on disk. The final program can be executed stand-alone or through a commercially available, menu-driven, image processing software package. Details concerning the ...
An engineering tool incorporating a scanning infrared radiometer, an imagedigitizer, a microcomputer, and the software to drive the system was developed to allow remote mapping of the temperature distribution in solar cavity receivers. Using enclosure analysis, the infrared image processing program extracts the irradiance map from the radiosity map of the cavity to yield an emissive power map. Using the calibration curve of the radiometer and the emissivity of the surface of the cavity, the emissive power map is transformed into a temperature map. The system was tested by comparing its calculated temperatures to temperatures measured by thermocouples at several locations on the surfaces of heated model cavity receivers. The average relative error for the cavities ranged from 4.6%--34.9%, with the relative error on the base usually less than half that on the wall. Some work was also carried out to compensate the detected ...
The video documents the results of a Small Business Innovative Research (SBIR-Phase II) project conducted for DARPA focusing on the use of all-source overhead remote sensor imagery for monitoring underground nuclear tests and related activities. The documentation includes: (1) the main unclassified body of the report; (2) a separate ground truth Annex; and (3) a separate classified Annex. Autometric's approach was to investigate the exploitation potential of the various sensors, especially the fusion of products from them in combination with each other and other available collateral data. This approach featured empirical analyses of multisensor/multispectral imagery and collateral data collected before, during, and after an actual underground nuclear test (named 'BEXAR'). Advanced softcopy digitalimage processing and hardcopy image interpretation techniques were investigated for the research. ...
This document contains 142 papers on PT3 (Preparing Tomorrow's Teachers to use Technology) from the SITE (Society for Information Technology & Teacher Education) 2002 conference. Topics covered include: a technology in urban education summit; student professional development; meeting NCATE (National Council of Teachers of English) standards; faculty use of WebCT; preparing teachers for the digital age; technology in K-8 multicultural classrooms; using immersive 360 degree images; consortium building; student evaluation; technology fellows; incentives that facilitate institutional change; impact of a temporary grant; a consortium for outstanding achievement in teaching with technology; changes implemented after technology professional development sessions; Web-based modules for teaching mathematics to minority students; student teaching technology sites; preservice teachers design technology-enhanced learning experiences; planning, ...
Exploration for epithermal Au has been active lately in the Aegean Sea of the eastern Mediterranean Basin, both in the islands of the Quaternary arc and in those of the back-arc region. The purpose of this study was the structural mapping and analysis for a preliminary investigation of possible epithermal gold mineralization, using remotely sensed data and techniques, structural and field data, and geochemical information, for a specific area on the Island of Lesvos. Therefore, Landsat-TM and SPOT-Pan satellite images and the Digital Elevation Model (DEM) of the study area were processed digitally using spatial filtering techniques for the enhancement and recognition of the geologically significant lineaments, as well as algebraic operations with band ratios and Principal Component Analysis (PCA), for the identification of alteration zones. Statistical rose diagrams and a SCHMIDT projection Stereo Net were generated from ...
Human beings are confronted with another grievous disaster - coal fire. The monitoring on underground coal bed combustion relied on drilling supervising in the past, but this method is not good. By taking the coal fire of Gulaben mine in Inner Mongolia Autonomous Region as an example, the monitoring methods of underground coal bed combustion were explored based on the hyperspectra and high-resolution remote sensing technology. By employing the OMIS imaging apparatus developed by Shanghai Institute of Technical Physics of Chinese Academy of Sciences, the airborne hyperspectral images and the characteristic spectra of different types were obtained and the temperature was measured synchronously on the ground. Then according to the correlation of DN value of the thermal infrared band and surface temperature, the image information was processed, the spectral features were analyzed, and the surface temperature retrieval model was ...
We investigated the isotropic diffusion coefficient (D') and fractional anisotropy (FA) in white matter (WM) during brain development, using an optimised diffusion-tensor imaging (DTI) method with whole brain coverage in a clinically acceptable time. We images 52 children with no evident neurological abnormality (30 boys, 22 girls aged 1 day-16 years) using high-angle DTI with optimised temporal gradient performance. D' and FA were calculated in 10 regions of interest in white matter. We saw that the age-related reduction in D' and increase in FA follow a mono- or biexponential model in white matter, probably depending on the compactness and myelination rate of the fibre tracts. In contrast to other areas, in which adult values were reached during the third year, there is a trend to continuous increase in FA in all deep white-matter areas, suggesting continuing maturation and organisation of deep tracts not detected on conventional MRI. (orig.)
A first-principles task-based approach to the design of medical ultrasonic imaging systems for breast lesion discrimination is described. This study explores a new approximation to the ideal Bayesian observer strategy that allows for object heterogeneity. The new method, called iterative Wiener filtering, is implemented using echo data simulations and a phantom study. We studied five lesion features closely associated with visual discrimination for clinical diagnosis. A series of human observer measurements for the same image data allowed us to quantitatively compare alternative beamforming strategies through measurements of visual discrimination efficiency. Employing the Smith-Wagner model observer, we were able to breakdown efficiency estimates and identify the processing stage at which performance losses occur. The methods were implemented using a commercial scanner and a cyst phantom to explore development of spatial ...
For good image quality using ultrasound inverse scattering, one alternately solves the well-posed forward scattering equation for an estimated total field and the ill-posed inverse scattering equation for the desired object property function. In estimating the total field, error or noise contaminates the coefficients of both matrix and data of the inverse scattering equation. Previous work on ill-posed inverse ultrasonic scattering commonly used Tikhonov regularization, which considers error only in the data. The solution so obtained is not precise enough to reconstruct the quantitative internal structure of a large or high-contrast object. This paper adopts the truncated total least squares method, simultaneously considering error and noise on both sides of the inverse scattering equation, and compares it with the classical Tikhonov regularization. We show that it can substantially improve reconstruction fit and image ...
The Soldier Information Requirements Technology Demonstration (SIREQ TD) project is an experimentation program to identify technologies that significantly enhance the performance of our future soldiers. One of the study series involved a 2 x 2 factorial comparison of the benefits of digital maps over paper maps, and the use of radios vs. no radios. Thirty-two Canadian regular force infantry soldiers performed force-on-force tactical assault missions in wooded terrain, with each soldier participating in all four test conditions. The radios were configured to operate in 4 subnets: 1 channel for each of the 2 Assault Groups (4 soldiers on a channel); a Section Commander/2IC channel; and an all-users channel. Note that in the no-radio conditions soldiers still operated the press-to-talk switch to allow recording of communications, but the speaker volume was set to zero. All communications were date/time stamped, identified as to the user and channel, and the audio was ...
This paper introduces examples of satellite imageries analysis and utilizations for safeguards activities. Recently, many kinds of satellite imageries are available in the world i.e., high-spatial resolution, multi- and hyper-spectral, multi-function, and multi-polarization radars. The problem is that how to obtain the required information from these digitalimages. The Japan Aerospace Exploration Agency (JAXA) has successfully launched the Advanced Land Observing Satellite (ALOS, the nickname is 'Daichi') on 24th January, 2006. The mission objectives are cartography, regional observation, disaster monitoring etc. ALOS has three instruments, PRISM, AVNIR-2, and PALSAR, to achieve these objectives. An overview of ALOS is provided. ALOS follows the Japanese Earth Resources Satellite- 1 (JERS-1) and the Advanced Earth Observing Satellite (ADEOS) and utilizes advanced land-observing technology. ALOS is fling in a Sun-synchronous orbit with an ...
Purpose: The predictive potential of tumor cell kinetic parameters may be improved when they are studied in relation to other microenvironmental parameters. The purpose of this investigation was to quantitatively categorize human tumor samples according to proliferation patterns. Second, it was examined whether these characteristics are retained after xenotransplantation. Methods and Materials: Fifty tumor samples from head-and-neck cancer patients were immunohistochemically stained for Ki-67 and vessels. Also, parts of the samples were transplanted into nude mice. Tumors were categorized according to previously described patterns of proliferation. Vascular and proliferation patterns were analyzed using an image processing system. Results: The 50 tumors were categorized into four patterns of proliferation by visual assessment: marginal (6), intermediate (10), random (21), and mixed (12). One tumor could not be classified. These patterns were ...
Tutorial on digital libraries. Site also contains links to other reference materials on digital libraries as well as links to courses on the subject. Keywords: Information Systems - Information Systems Applications, Information Storage and Retrieval, Database Management, multimedia
Objective: The paper describes and evaluates the use of Clinical Digital Libraries Project (CDLP) digital library collections in terms of their facilitation of timely clinical information...Full Text Available
A form for the clinical evaluation of bovine digital disease was developed. In this article, each section of the resulting Digit Evaluation Form is discussed and justified. By following the...Full Text Available
Qualitative technetium Tc 99m bone scintigraphy using phosphate compounds and gallium 67 scintigraphy were described as a helpful means in diagnosing necrotizing external otitis (NEO). They were, however, claimed to be nonspecific. Quantitative Tc 99m methylene diphosphonate bone scintigraphy and gallium 67 scintigraphy were performed in eight patients with NEO and in 20 patients with severe external otitis, in order to prove usefulness of scintigraphy in the diagnosis of NEO. Ratios of lesion to nonlesion for bone scintigraphy were 1.67 {plus minus} 0.16 in patients with NEO and 1.08 {plus minus} 0.09 in patients with severe external otitis, and for gallium 67 scintigraphy they were 1.35 {plus minus} 0.24 in NEO patients and 1.05 {plus minus} 0.03 in patients with severe external otitis. There was no difference in uptake between diabetic patients with severe external otitis and nondiabetic patients. The scintigraphic studies were also evaluated using a qualitative ...
Qualitative technetium Tc 99m bone scintigraphy using phosphate compounds and gallium 67 scintigraphy were described as a helpful means in diagnosing necrotizing external otitis (NEO). They were, however, claimed to be nonspecific. Quantitative Tc 99m methylene diphosphonate bone scintigraphy and gallium 67 scintigraphy were performed in eight patients with NEO and in 20 patients with severe external otitis, in order to prove usefulness of scintigraphy in the diagnosis of NEO. Ratios of lesion to nonlesion for bone scintigraphy were 1.67 #+-# 0.16 in patients with NEO and 1.08 #+-# 0.09 in patients with severe external otitis, and for gallium 67 scintigraphy they were 1.35 #+-# 0.24 in NEO patients and 1.05 #+-# 0.03 in patients with severe external otitis. There was no difference in uptake between diabetic patients with severe external otitis and nondiabetic patients. The scintigraphic studies were also evaluated using a qualitative scoring method (scores 0 to ...
The digital AVR must have the level of redundancy and control functions that conform to the configuration of the excitation control system and to the importance of a particular generator for the user. The digital AVR is not simply a digital version of the analog AVR, but can realize sophisticated control functions that were difficult to achieve with analog circuits, thus making it possible to enhance the stability of power system by PSS (power system stabilizer). This paper describes the test results of the digital AVRs applied to power plants, their system configuration and functions, as well as the outline of an auto-tuning PSS or AT-PSS planned to be incorporated in the digital AVR in the future.
Full text: Introduction. Children, especially premature infants and neonates, are at a much higher risk to obtain an X ray induced disturbance of life - particularly cancer. On the one hand this is due to their longer life expectancy and on the other hand it is due to their higher cell proliferation rate. The paediatric radiology unit of the Inselspital Bern recently installed some of the most advanced X ray equipment nowadays available. It is based on the two latest digital technologies: double read computed radiography (CR) and direct digital radiography (DR). Only the implementation of these digital radiography systems permits the digital acquisition and additionally the analysis of acquired data. The systematic analysis of large amounts of biometric data and exposition data is the basis for further dose reduction and a systematic quality control (QC). Patients are increasingly critical concerning ...
A novel phantom has been developed to measure the modulation transfer function (MTF) in 3D for x-ray computed tomography. The phantom consists of three tungsten wires, positioned nearly orthogonal to each other. Simultaneous measurements of the MTF are taken at various locations along the three orthogonal reconstructed planes. Our computed mammotomography (CmT) system uses a Varian Paxscan 2520 digital x-ray detector which can be positioned anywhere in ~2pi steradian band and can have arbitrary trajectories. With a half-cone beam geometry and with the phantom positioned near the center of rotation, projection images are acquired over 360 degrees. Various 3D orbits are evaluated including vertical axis of rotation and saddle. Reconstructions were performed using an iterative ordered-subsets transmission algorithm on rebinned projection images, using various numbers of iterations. Rotation of reconstructed slices isolated ...
Objective:This paper describes the Lamar Soutter Library's process and costs associated with digitizing 300 doctoral dissertations for a newly implemented institutional repository...Full Text Available
Dynamic quantitative bone scintigraphy was performed on 31 men with prostatic carcinoma before orchiectomy as well as 2 weeks, 2 and 6 months postoperatively. After injection of technetium methylene diphosphonate Tc 99m ("9"9"mTc-MDP) the count rate was recorded as serial images over the lower thoracic and all the lumbar vertebrae from 1 to 240 min post-injection. Thirteen men had normal bone scintigrams with no changes in "9"9"mTc-MDP content at the four different investigation times. Eighteen men had skeletal metastases. Throughout the study half of the abnormal vertebrae in these patients showed an abnormal count rate after only 6 min post-injection. After 1 h it was possible in almost all abnormal vertebrae to predict abnormal bone uptake. In response to therapy a 'flare phenomenon' with an increase in count rate was seen 2 weeks after orchiectomy followed by a decrease 2 months postoperatively in most of the abnormal vertebrae. The count ...
A technique for quantitative determination of cephalothin and desacetylcephalothin in serum using a method based on high-pressure liquid chromatography is described. Both compounds were quantitatively...Full Text Available
Porous flow occurs in a wide range of materials and applies to many commercially relevant applications such as oil recovery, chemical reactors and contaminant transport in soils. Typically, breakthrough and pressure curves of column floods are used in the laboratory characterization of these materials. These characterization methods lack the detail to easily and unambiguously resolve flow mechanisms with similar effects at the core scale that can dominate at the aquifer or oil field scale, as well as the effects of geometry that control the flow at interfaces as in a perforated well or the inlet of an improperly designed column. Non-invasive imaging techniques such as MRI have been shown to provide a far more detailed characterization of the properties of the solid matrix and flow, but usu...
The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.
339 CT und 95 MRT examinations in 210 partients were evaluated retrospectively to determine the value of CT and MRT for follow-up of head and neck tumors and for diagnosing recurrences. Semi-quantitative evaluation of tumor extent during and after radiotherapy showed advantages for MRT since changes induced by treatment, particularly oedema, produced less contrast loss in the images. CT had a sensitivity of 81% for the recognition of recurrences; this was 92% for MRT. Specificity for CT was 76% and for MRT 86%. Concerning the reliability of individual diagnostic criteria, space occupying lesions were the most valuable in CT diagnosis. For MRT, space occupying lesions and infiltration into neighbouring structures were of equal value. Because of differences in the nature of the signals, MRT proved better than CT in characterising recurrent masses and this improved the differentiation between scarring and local tumour recurrence. (orig.).
We propose a combined experimental (Atomic Force Microscopy) and theoretical study of the structural and dynamical properties of nucleosomes. In contrast to biochemical approaches, this method allows to determine simultaneously the DNA complexed length distribution and nucleosome position in various contexts. First, we show that differences in the nucleo-proteic structure observed between conventional H2A and H2A.Bbd variant nucleosomes induce quantitative changes in the in the length distribution of DNA complexed with histones. Then, the sliding action of remodeling complex SWI/SNF is characterized through the evolution of the nucleosome position and wrapped DNA length mapping. Using a linear energetic model for the distribution of DNA complexed length, we extract the net wrapping energy of DNA onto the histone octamer, and compare it to previous studies.
Digital libraries continue to flourish. At the same time, the principles of user-centered design and the practice of usability testing have been growing in popularity, spreading their influence into the library sphere. This article explores the confluence of these two trends by surveying the current literature on usability studies of digital libraries. This article focuses on the methodology of studies of multimedia digital libraries. (Contains 1 table and 45 notes.)
The meeting was arranged into the following sessions: introductory; advanced ceramics and ceramic composites; ceramic and metal matrix composites; electronic materials and devices; acoustoelasticity, stress, and texture; composites-porosity, strength, and UT propagation; process modeling and monitoring; thermal wave physics; material properties, composites, surfaces, and interfaces; acoustic emission; ferromagnetic materials; new sensors; NDE reliability assessment; elastic wave scattering and propagation; image analysis, data storage, and signal processing; UT transducers; weldments and bonded materials; eddy current models; unified life cycle engineering; x rays, CT, and NMR; eddy current probes and instruments; acoustic microscopy imaging, and reconstruction; signal processing, measurement techniques, and systems; NDE applications of artificial intelligence; crack behavior influenced by history; inversion procedures for UT and EC; process ...
SummaryThis paper evaluates the status of digitization in 30 Nigerian university libraries with a view to identifying the status, progress, prospects and challenges to digitize library materials and form the basis of providing a roadmap to successful execution of digitization projects. The study assessed the status of digitization of past question papers, theses and dissertations in Nigerian university libraries from May to September 2006 through a self-administered questionnaire, site visits and interviews. It was found that, though there are automation services in those universities, there is no digitization of these materials mentioned in the surveyed institutions. The major obstacles militating against digitizing in the university libraries include lack of funds, lack of appropriate fa...
The purpose of this study was to clarify the benefits of digital lateral chest radiogram. In the basic study, the modulation transfer factor (MTF) and the wiener spectra (WS) of conventional screen film (CSF) and Fuji computed radiography (FCR) were measured. The visibility of the simulated nodules on FCR using 3 human bodies was subjectively compared with that on CSF by 13 observers. In the clinical study, the visibility of the normal structures on FCR was subjectively compared with that on CSF using 50 lateral chest radiograms by 10 observers. The diagnostic performance to detect pulmonary nodules on FCR was also compared with that on CSF using each 30 positive and negative cases by 8 observers. In the basic study, the MTF of FCR was superior to that of CSF, and the WS of FCR displayed in half size was superior to that of CSF. In all exposure conditions, the visibility of the nodules on FCR in the pulmonary apex was inferior to that on CSF, while FCR was superior ...
The purpose of this study was to clarify the benefits of digital lateral chest radiogram. In the basic study, the modulation transfer factor (MTF) and the wiener spectra (WS) of conventional screen film (CSF) and Fuji computed radiography (FCR) were measured. The visibility of the simulated nodules on FCR using 3 human bodies was subjectively compared with that on CSF by 13 observers. In the clinical study, the visibility of the normal structures on FCR was subjectively compared with that on CSF using 50 lateral chest radiograms by 10 observers. The diagnostic performance to detect pulmonary nodules on FCR was also compared with that on CSF using each 30 positive and negative cases by 8 observers. In the basic study, the MTF of FCR was superior to that of CSF, and the WS of FCR displayed in half size was superior to that of CSF. In all exposure conditions, the visibility of the nodules on FCR in the pulmonary apex was inferior to that on CSF, while FCR was superior ...
Promoted as the first academic conference to be held completely in graphical cyberspace, Avatars 98 took place in November 1998. The virtual conference site was built and inhabited using software that supports multi-party presence over the Internet in a simulated, navigable environment. During the conference, avatar-embodied speakers using text chat performed to virtual audiences, 'webcams' (re)broadcast live video images of CNN and other remote sites, and a 'webcast' sent audiovisual representations captured by video camera of certain key participants in their physical locations. Such a novel and spectacular multi-media event raises many questions. How do we conceive of the recent developments in media technology and social computing that are impacting on what we have traditionally called 'the mass media'? How is interaction and talk mediated and adapted to new media genres? And how do participants construct and maintain senseful talk in a sometimes bewildering, ...
Hyaluronate (HA) distribution patterns were examined in the cranial mesenchyme underlying the mesencephalic neural folds of mouse embryos maintained in roller tube culture. Using standard image-processing techniques, the digitizedimages of Alcian blue-stained or 3H-glucosamine-labeled sections digested with an enzyme specific for HA, were subtracted from adjacent, undigested sections. The resultant difference picture images (DPI) accurately depicted the distribution of stained or labeled HA within the cranial mesenchyme. 3H-glucosamine-labeled HA was distributed uniformly throughout the cranial mesenchyme as 12, 18, and 24 hr of culture. By contrast, the mesenchyme was uniformly stained with Alcian blue at 12 hr, but stain intensity decreased in the central regions of the mesenchyme at 18 and 24 hr. HA distribution patterns were also examined in the cranial mesenchyme of embryos cultured in the ...
Hepatocellular carcinoma (HCC) is characterized by tumor vascularization from the hepatic artery. The objective of our work was to compare color Doppler ultrasonography (CDU), including power Doppler ultrasonography (PDU) with radiographic imagings with contrast medium in regard to the detection of the arterial tumor vascularity of small hepatocellular carcinomas (HCC). We examined 42 small HCC lesions 2 cm or less in diameter in 37 patients for arterial tumor vascularity by conventional CDU, PDU, dynamic computed tomography (dCT), digital subtraction angiography (DSA), and CT hepatic arteriography (CTA). Color images were detected in 25 (59.5%) and 28 (66.7%) of the 42 lesions with conventional CDU and PDU, respectively, and tumor vascularity was detected in 26 (61.9%) by dCT, 23 (54.8%) by DSA, and 29 (69.0%) by CTA. Tumor vascularity could be detected in 51.9% by PDU and CTA, more than by conventional CDU, dCT, and DSA ...
Abstract This paper tries to investigate the problem of memory through one of its most intriguing patterns - chiasmus - reflected in old poetry, sacred texts, philosophy and theology, visual arts, as well as biology. It aims to search for some provisory explanation of why man was able once to acquire such excellence in memorizing internally thousands of lines of poetry, whereas now memory is expelled outside the human body and mind in a mere digital file. Contrasting the so-called "wish-dream for immortality" of the contemporary post-human body, this paper takes another path and looks into some old cosmologies and visions in which chiasmus constantly emerged as an enduring cultural paradigm with ontological relevance. Spanning from Plato to Christian theology, up to the contemporary Neo-Platonism of archetypal psychology, this paper hopes to put forth, if not a theory, at least a vision about man and cosmos, cosmos and man, a chiastic epiphany in which the body and ...
The ability to use an acoustic stethoscope to detect lung and/or heart sounds, and then to then communicate one's interpretation of those sounds is an essential skill for many medical professionals. Interpretation of lung and heart sounds, in the context of history and other examination findings, often aids the differential diagnosis. Bedside assessment of changing auscultation findings may also guide treatment. Learning lung and heart auscultation skills typically involves listening to pre-recorded normal and adventitious sounds, often followed by laboratory instruction to guide stethoscope placement, and finally correlating the sounds with the associated pathophysiology and pathology. Recently, medical simulation has become an important tool for teaching prior to clinical practice, and for evaluating bedside auscultation skills. When simulating cardiovascular or pulmonary problems, high-quality lung and heart sounds should be able to accurately corroborate other findings such as ...
A magnetic tape consisting of oil-shale Fischer assay data for selected well cores in the Piceance Creek Basin was prepared as a supplement to NTIS tape PB-230 607/AS. Both tapes serve as a data base for calculating oil-shale resources (Pitman, 1981). The tape is in standard IBM format and has the following specifications: EBCDIC (IBM standard), card-image, blocksize 1720 (blocked 20 to 1), record length 86, odd parity, 1,600 bpi, 9-track, no label tape. Each data file on the tape consists of records containing oil-shale analyses for one well core. The first record in a data file consists of a well-core identifier which is a three-digit number preceded by the character 'C'. The second record contains the well name and location, and the remaining records contain Fischer assay data.
Using the Sloan Digital Sky Survey (SDSS) and the FIRST (Faint Images of the Radio Sky at Twenty Centimeters) catalogs, we examined the optical environments around double-lobed radio sources. Previous studies have shown that multi-component radio sources exhibiting some degree of bending between components are likely to be found in galaxy clusters. Often this radio emission is associated with a cD-type galaxy at the center of a cluster. We cross-correlated the SDSS with the FIRST catalog and measured the richness of the cluster environments surrounding both bent and straight multi-component sources. This led to the discovery and classification of a large number of galaxy clusters out to a redshift of z ~ 0.5. We divided our sample into smaller subgroups based on their optical and radio properties. We find that FR I radio sources are more likely to be found in galaxy clusters than FR II sources. Further, we find that bent radio sources are more ...
A computerized system for monitoring dose-area product (DAP) has been developed for region of interest (ROI) fluoroscopy in which patient exposure is reduced using an x-ray attenuating filter with an aperture. The system includes an IBM compatible computer which is connected through an IEEE-488 interface to an electrometer which measures the charge from a DAP ionization chamber. A digital input/output board connects the computer to the filter placement device to determine whether the filter is in or out of the beam, and to the x-ray generator to determine when the exposure is due to spot filming. The computer logs the DAP from conventional fluoroscopy, ROI fluoroscopy and spot filming separately, applying the appropriate calibration factor for each. Measured DAPs, fluoroscopic DAP rates and exposure times are displayed in real-time. The system has been installed in a GI fluoroscopic room so that the dose-reduction potential of ROI imaging can ...
Purpose - The purpose of this paper is to describe the processes and procedures utilized by Jacksonville State University's Houston Cole Library to digitize an oral history collection and provide access to it through the Library's catalog, web presence, and the state-wide digital repository initiative, Alabama Mosaic (see www.alabamamosaic.org). Design/methodology/approach - The paper is based on the Library's experiences in acquiring, digitizing, creating metadata for and making accessible a collection of oral histories. Findings - The paper describes the obstacles overcome, issues encountered, procedures established, and ramifications of the project. Practical implications - Many institutions are currently digitizing unique collections as part of repository initiatives, both institutiona...
Quantitative bone scintigraphy was performed in patients with prostatic carcinoma before orchiectomy as well as two weeks, two and six months after operation. The count rate was recorded as serial gamma camera images over the lower thoracic and all lumbar vertebrae from 1 to 240 min and at 24 h after injection of "9"9"Tc"m-MDP. In almost all abnormal vertebrae an increased count rate was observed within one hour after injection. Most of the vertebrae which were considered normal at 4 h after injection, but had an increased 24h/4h ratio developed into abnormal vertebrae later in the study. The patients with normal bone scintigrams showed no change in "9"9Tc"m-MDP uptake during the study. The reproducibility of quantitative bone scintigraphy was found to be #+-# 7% (1 SD). In response to therapy, most of the patients with abnormal bone scintigrams showed an increase in count rate two weeks after operation followed by a ...
Objectives: To minimize movement artifacts during tracer imaging studies, the animals are generally sedated. Although many reports describe the effect of barbiturates on brain function, less is published about the general impact on the extracerebral metabolism and tracer biodistribution. This report describes the influence of pentobarbital on tumor uptake of ["1"2"3I]-2-iodo-L-phenylalanine (["1"2"3I]-2I-L-PA) using dissection and nuclear imaging. Methods: R1M tumor-bearing athymic mice were divided into two populations: untreated and pentobarbital-treated. Each group was subjected to dynamic and static planar imaging and organ dissection after ["1"2"3I]-2I-L-PA injection. Two-compartment blood modeling was performed. Analysis of variance (ANOVA), t test and clustered boxplot analyses were used to compare the results between the treatment groups and between the data acquisition methods. Results: Two-compartment blood ...
Forty-four patients with small cell carcinoma of the bronchus underwent CT and MR studies of the brain to detect cerebral metastases. All patients were studied with contrast-enhanced CT scans, short (T1-weighted) and long (T2-weighted), spin-echo (SE) and FLASH 90 grades sequences were also obtained. A quantitative comparison of the results was carried out to assess the sensitivity of the different techniques in the detection of brain metastases according to lesion diameter. Metastases were identified in 19/44 patients (43%). All techniques detected the lesions >2 cm; of the metastases <2 cm, 63/124 (51%) were detected only by GdDTPA SE-T1 and FLASH sequences and 11 more (9%) only by Gd-DTPA SE-T1 scans. All the lesions identified oh enhanced CT scans or on T2-weighted images were easily detected by Gd-DTPA scans. CT sensitivity was higher than that of pre-contrast SE-T1 and FLASH studies and only slightly lower than that of T2-weighted ...
Quantitative evaluation of CRT and CR observations in indentification of malignancy using phantom and clinical data. A breast phantom and a total of 40 patients were imaged by Fuji computed radiography (FCR). The images were interpreted twice by six radiologists both on CR film (2510 x 2000 pixels x 10 bits, 0.1 mm spatial resolution) and on a CRT monitor (1568 x 1152 pixels x 10 bits, 0.1 mm pixel size with double expansion) with image processing parameters of a toutine (RN 1.0, RE 0.2), for a calcification (RN 9.0, RE 4.0) and for a mass (RN 7.0, RE 2.0). The forty clinical cases included breast diseases with calcifications, masses, and normal breasts. Two-tailed t-test was performed to analyze interpretation of simulated microcalcifications and masses in the phantom. The receiver operating characteristic (ROC) analysis was performed to evaluate clinical cases. In all interpretation studies using both ...
An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)
The purpose of this study was to use high-resolution magnetic resonance (MR) imaging combined with image analysis to investigate the three-dimensional (3D) trabecular structure, anisotropy, and connectivity of human vertebral, femoral, and calcaneal specimens. The goal was to determine whether: (a) MR-derived measures depict known skeletal-site-specific differences in architecture and orientation of trabeculae; (b) 3D architectural parameters combined with bone mineral density (BMD) improve the prediction of the elastic modulus using a fabric tensor formulation; (c) MR-derived 3D architectural parameters combined with BMD improve the prediction of strength using a multiple regression model, and whether these results corresponded to the results obtained using higher resolution depictions of trabecular architecture. A total of 94 specimens (12 x 12 x 12 mm cubes) consisting of trabecular bone only were obtained, of which there were 7 from the ...
WELLOG is a system of programs developed at the Earth Science Laboratory to be used to digitize well logs and perform some analysis and plotting of the data. Multiple logs can be plotted side by side for correlation analysis and up to three logs can be plotted in a cross plot. Data entry and editing functions are also provided by the programs. This system of well log interpretation programs is presently operating on the University of Utah UNIVAC 1108 computer. Digitizing of well logs is accomplished by an old model CALMA (off-line) digitizer. Those parts of WELLOG that handle the digitized data tapes are extremely machine dependent. The parts of WELLOG that produce the plots and handle the data beyond the digitized data tape are more portable.
In Japan, the development of next-generation Light Water Reactor has been launched since April 2008. The development program will be completed in 2015. The purpose of development is to cope with the replacement for existing nuclear power plants after 2030 in Japan and the expanding demand for nuclear power in the world; 'Nuclear Renaissance.' The reactor also aims to be global standard at around 2030. The requirements for global standard and domestic users have been investigated through the feasibility study of past 2 years, 2006-2007, and six innovative features or 'Core-Concepts' were established as follows. A) Reactor core system with uranium enrichment above 5% for significant decrease of spent fuel discharge and prominent higher availability B) Long-life materials and innovative water chemistry technologies for 80 years plant lifetime and significant reduction of occupational dose C) Seismic isolation technologies to standardize plant design independent from site conditions D) ...
Described herein are the results of the FY1994 research program for analysis and evaluation for thin film solar cells. The study on quantitative analysis of hydrogen atoms in a plasma determines quantity of hydrogen atoms in the plasma of monosilane diluted with hydrogen. It is found, contrary to expectation, that quantity of hydrogen atoms in the plasma decreases as it is more diluted with hydrogen. The study on light-induced degradation of the thin chlorine-base amorphous silicon films confirms that the plasma CVD method with 20% of dichlorosilane gas added to monosilane gas produces the thin amorphous silicon film 3 times faster than the conventional method. The thin film has essentially the same defect density as the one prepared by the conventional method, showing good photoelectric characteristics. The thin film of chlorinated amorphous silicon has a 1 digit lower defect density than the conventional one of amorphous silicon, as revealed ...
Automatic segmentation of anatomical structures in medical images is a valuable tool for efficient computer-aided radiotherapy and surgery planning and an enabling technology for dynamic adaptive radiotherapy. This paper presents the design, algorithms and validation of new software for the automatic segmentation of CT images used for radiotherapy treatment planning. A coarse to fine approach is followed that consists of presegmentation, anatomic orientation and structure segmentation. No user input or a priori information about the image content is required. In presegmentation, the body outline, the bones and lung equivalent tissue are detected. Anatomic orientation recognizes the patient's position, orientation and gender and creates an elastic mapping of the slice positions to a reference scale. Structure segmentation is divided into localization, outlining and refinement, performed by procedures with implicit ...
Initial major applications of neutron radiography (NR) to nuclear engineering were nondestructive inspections of nuclear fuel, control rods, reactor materials and some other components. Increase in the available neutron flux over 10{sup 8} n/cm{sup 2}s at the JRR-3M thermal neutron radiography facility (TNRF) in 1991 has expanded the application field to the dynamic but clear imaging of moving objects and fluid phenomena. The JRR-3M TNRF is facilitated with three major imaging systems, being characterized by spatial and/or temporal resolutions: 1. Static neutron radiography (SNR), 2. real-time neutron radiography (RNR) with an imaging rate of 30 frames/s and 3. High-frame-rate neutron radiography (HFRNR). SNR has been used for three-dimensional visualization of air-water two-phase flows in a simulated rod bundle. Three-dimensional computed tomography clearly illustrated average void fraction distributions around tie ...
BackgroundThe purpose of our investigation was to compare a digital templating system to conventional templating techniques when preoperatively planning for total hip arthroplasty.MethodsWe...Full Text Available
In summer 2000, the Cushing/Whitney Medical Library at Yale University began a demonstration project to digitize classic articles in neurosurgery from the late 1800s and early 1900s. The objective of...Full Text Available
This study used a PCR-based approach targeting 16S rRNA gene fragments to determine the occurrence and association of the three bovine digital dermatitis (BDD) treponeme phylogroups within lesions found...Full Text Available
Several widely recognized sources of nomenclature regarding the bovine external digit were reviewed, compared, and utilized in a clinical survey of bovine digital disease. During this process, some...Full Text Available
sharing data and computational resources, and accessing information in digital libraries." Bill Wulf (1989) In a Collaboratory, the presentation/meeting concept embodied...
... program incorporates the proven concepts of advanced distributed learning, modeling and simulation, and electronic digital libraries (Figure 1) to ...
02.10.10 - NASA and Texas Instruments are using the theme of human space exploration to develop digital libraries of math and science problems for high ...
An important goal for digital libraries is to enable researchers to more easily explore related work. While citation data is often used as an indicator of relatedness, in this paper we demonstrate that digital access records (e.g. http-server logs) can be used as indicators as well. In particular, we show that measures based on co-access provide better coverage than co-citation, that they are available much sooner, and that they are more accurate for recent papers.
The paper represents the result of research in the field of digital libraries functionalities in the context of new Grid infrastructure support. It is defined a new vector of knowledge society, informational vector - content vector. It presents a Grid European project which includes Romanian partners, and it defines on this base a digital library model which can be applied for the libraries in Romania.
... Title : Optical Images Due to Lenses and Mirrors. ... Abstract : The properties of real and virtual images formed by lenses and mirrors are reviewed. ...
The investigation of interfaces between thin organic films and metal surfaces is a field of highest interest because it represents the basis for future applications of organic electronic devices. In this context, phtalocyanines are of particular interest since repulsive intermolecular interaction was found recently for this group of organic molecules. Tin(II)-phtalocyanine (SnPc) is non-planar and can adsorb in two different geometries: with the Sn atom pointing downwards (Sn down) or upwards (Sn up). In our group different Pc molecules have previously been studied using several experimental techniques like SPA-LEED or XSW. Here we present STM studies of SnPc on Ag(111), taken at different coverages and temperatures, and discuss the results in the context of our previous findings. At low coverages the formation of chains can be observed for Sn down molecules while Sn up molecules tend to stay separated. This originates from a strong interaction with the substrate which leads to a ...
Biodiesel made from vegetable oil is among the most desirable of renewable energy sources because it can be a substitute for diesel oil. However, biodiesel from soybean or corn can be confronted with a food crisis. Microalgae is a new biodiesel source which contains high oil lipids with a high growth rate, and which also offers value-added products from the residue, such as cosmetics, health functional food or pharmaceuticals. Microalgae are best cultivated in photo-bioreactors (PBRs) where light, nutrients, carbon dioxide and temperature can be controlled. Despite the current availability of PBRs, only a few can be practically used for mass production. Computational fluid dynamics (CFD) was used in this study to design an optimum bubble-column PBR for mass production of microalgae. Multi-phase models including bubble movement, meshes and time step independent tests were considered to develop the 3-dimensional CFD model. Particle Image Velocimetry (PIV) tests were ...
Hepatobiliary scintigraphy is the only non-invasive technique providing real-time assessment of hepatocytes function and bile progression from the liver to the intestine; for this reason it is of great importance in the study of jaundice and many other disorders of the liver and the biliary tract in children. Ultrasonography is the initial method of evaluating the intra- and extrahepatic bile ducts dilatation: the differential diagnosis between biliary atresia and neonatal hepatitis cannot however be done without hepatobiliary scintigraphy. Cystic fibrosis patients also require hepatobiliary scintigraphy; liver and biliary tract disease can really occur independently of the underlying disease severity and the presence of steatorrhoea. Hepatobiliary imaging in children who have undergone liver transplantation is of major importance; it can assess vascularity, parenchymal function biliary drainage, possible presence of a bile leak and obstruction; it has very good ...
The Compton backscatter technique has been applied to lap-joint in aircraft structure in order to determine mass loss due to exfoliative corrosion of the aluminum alloy sheet skin. The mass loss of each layer has been estimated from Compton backscatter A-scan including the aluminum sheet, the corrosion layer, and the sealant. A Compton backscattering imaging system has been also developed to obtain a cross-sectional profile of corroded lap-splices of aging aircraft using a specially designed slit-type camera. The camera is to focus on a small scattering volume inside the material from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the layered structure is scanned by moving the scattering volume through the thickness direction of the specimen. The theoretical model of the Compton scattering based on Boltzmann transport theory is presented for ...
Quantitative I-131 labelled Peanut lectin (I-131-PNA) renal clearance was determined in dogs before and after a 5 day single cycle cis-platinum chemotherapy regimen (0.5mg/Kg/day). Results were statistically compared with E.R.P.F. (I-131-Hippuran), G.F.R. (Tc-99m-DTPA), and serum biochemistry and correlated with histopathology. I-131-PNA clearance was significantly reduced in all dogs 5 days after cessation of cis-platinum treatment (mean #DELTA#S% = 71.3%) and similar reductions in the gamma camera derived renogram peak were demonstrated (mean #DELTA#S% = 65.8%). E.R.P.F. was noted to drop by a minor degree (mean #DELTA#S% = 20.9%) post treatment. G.F.R. was diminished (mean #DELTA#S% = 46.6%) and serum creatinine elevated (mean #DELTA#S% = 42.7%) in all dogs compared to their pretreatment values. Histopathology demonstrated variable degrees of tubular toxicity ranging from mild to severe. The degree of change of the I-131-PNA values was significantly greater than ...
Diseases of the mandible affect the soft tissues aside from the osseous manifestation. This can be shown clearly and in great detail by magnetic resonance imaging (MRI). MRI is the gold standard in the diagnostic evaluation of any internal derangement of the temporomandibular joint. Dental MRI requires high resolution techniques and in some cases also intravenous administration of contrast material. These techniques allow delineation of the neurovascular bundle. In the past few years new indications were formulated, for example, the evaluation of the integrity of the inferior alveolar nerve in trauma and in radicular cysts. New quantitative methods now enable insights into the pathophysiology. The objective of this review is to communicate accepted indications for MRI of the mandible and to present innovative applications. (orig.) [German] Mandibulaere Erkrankungen beteiligen neben dem Knochen Weichteilstrukturen, die sich mit der MRT klar und ...
The evaluation of biological markers is recognized as necessary to the future of toxicology, epidemiology, and quantitative risk assessment. For biological markers to become widely accepted, their validity...Full Text Available
The incidence of columnar cell lesions in breast core needle biopsies since full-field digital mammography in comparison with screen-filmed mammography was analyzed. As tiny microcalcifications characterize columnar cell lesions at mammography, we hypothesized that more columnar cell lesions are diagnosed since full-field digital mammography due to its higher sensitivity for microcalcifications. In all, 3437 breast core needle biopsies performed in three hospitals and resulting from in total 55?159 mammographies were revised: 1424 taken in the screen-filmed mammography and 2013 in the full-field digital mammography period. Between the screen-filmed mammography and full-field digital mammography periods, we compared the proportion of mammographies that led to core needle biopsies, the...
The study was performed for evaluating the risk effect of digital systems on the total plant. Based on risk monitor, a fault tree model for the Korean Standard Nuclear Power Plants (KSNPP), we integrate the fault-tree models for Digital Plant Protection System (DPPS) and Digital Engineered SaFety Actuation System (DESFAS) which are the most important safety-critical I and C systems in the KSNPP. In this study, however, three important factors (the probabilities of manual actuation failure, the software failure probability, and the watchdog timer fault coverage) are treated as the variables of the sensitivity study because quantification methodologies for these factors are not developed yet. Not only the unavailability of digital safety-critical system itself, but also the risk effect of digital systems on the total plant should be assessed to prove the safety of ...
This work describes a combinatorial model for estimating the reliability of the embedded digital system by means of multi-state function. This model includes a coverage model for fault-handling techniques implemented in digital systems. The fault-handling techniques make it difficult for many types of components in digital system to be treated as binary state, good or bad. The multi-state function provides a complete analysis of multi-state systems as which the digital systems can be regarded. Through adaptation of software operational profile flow to multi-state function, the HW/SW interaction is also considered for estimation of the reliability of digital system. Using this model, we evaluate the reliability of one board controller in a digital system, Interposing Logic System (ILS), which is installed in YGN nuclear power units 3 and 4. Since the proposed ...
The Linac Coherent Light Source (LCLS) is required to deliver a high quality electron beam for producing coherent X-rays. As a result, high resolution beam position monitoring is required. The Beam Position Monitor (BPM) digitizer acquires analog signals from the beam line and digitizes them to obtain beam position data. Although Matlab is currently being used to test the BPM digitizer?s functions and capability, the Controls Department at SLAC prefers to use Experimental Physics and Industrial Control Systems (EPICS). This paper discusses the transition of providing similar as well as enhanced functionalities, than those offered by Matlab, to test the digitizer. Altogether, the improved test stand development system can perform mathematical and statistical calculations with the waveform signals acquired from the digitizer and compute the fast Fourier transform (FFT) of the signals. ...
Purpose: The aim of this study was to test the feasibility of iliac artery stent placement under MR guidance with real-time MR radial scanning in an animal model. Materials and methods: The experiments were performed on three pigs in a 1.5 T scanner. Radial scanning with a gradient echo technique (T{sub R} 8.4 ms, T{sub E} 3.6 ms, flip angle 10 ) was used. A dedicated backprojector performed the reconstruction of the raw data in real-time. The resulting MR-images were displayed on LCD screens beside the magnet. The sliding window reconstruction technique allowed image acquistion at a frame rate of 16 images per second. MR-compatible self-expanding stents with a diameter of 8 mm and a length of 3 cm were placed into the left iliac artery. Their positions were verified by digital subtraction angiography (DSA) and compared to MRI. Results: All stents were successfully placed. Stent positions as monitored ...
Surgical resection is the only curative treatment strategy for intrahepatic cholangiocarcinoma (CC). Therefore, accurate staging is essential for appropriate management of patients with CC. We assessed the usefulness of 2-["1"8F]fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) in the staging of CC. We undertook a retrospective review of FDG PET images in 21 patients (10 female, 11 male; mean age 57 years) diagnosed with CC. Ten patients had hilar CC and 11, peripheral CC. Patients underwent abdominal magnetic resonance imaging (MRI) (n=20) and computed tomography (CT) (n=12) for the evaluation of primary tumours, and chest radiography and whole-body bone scintigraphy for work-up of distant metastases. For semi-quantitative analysis, the maximum voxel standardised uptake value (SUV_m_a_x) was obtained from the primary tumour. All peripheral CCs showed intensely increased FDG uptake, and some demonstrated ...
The central benzodiazepine receptor tracer [N-methyl-"1"1C]iomazenil (Ro 16-0154) was synthesized by alkylation of the desmethyl precursor noriomazenil with ["1"1C]methyl iodide. The ["1"1C]CH_3I (prepared by reduction of ["1"1C]CO_2 with LiAlH_4 followed by reaction with HI) was reacted with noriomazenil inN,N -dimethylformamide and Bu_4N"+OH"- for 1 min at 80 deg. C and purified by HPLC (C_1_8, 34% CH_3CN/H_2O, 7 mL/min). The product was obtained with synthesis time 35 #+-# 5 min (mean #+-# SD, n = 7), radiochemical yield (EOB) 36 #+-# 16%, radiochemical purity 99 #+-# 1%, and specific activity 5100 #+-# 2800 mCi/#mu#mol. Absorbed radiation doses were calculated from previously acquired human biodistribution data. The urinary bladder wall received the highest dose (0.099 mGy/MBq) for 4.8 h voiding interval and the effective dose equivalent was 0.015 mSv/MBq. After i.v. injection of ["1"1C]iomazenil in an adult baboon or healthy human volunteer, radioactivity accumulated in the cortex ...
We examined the abnormalities of regional cerebral blood flow(rCBF) in children with attention deficit hyperactivity disorder(ADHD) without comorbidity using statistical parametric mapping(SPM) method. We used the patients with not compatible to DSM-IV diagnostic criteria of ADHD and normal rCBF pattern in visual analysis as normal control children. Tc-99m ECD brain SPECT was performed on 75 patients (M:F=64:11, 10.0{+-}2.5y) with the DSM-IV diagnostic criteria of ADHD and 13 normal control children (M:F=9:4, 10.3{+-}4.1y). Using SPM method, we compared patient group's SPECT images with those of 13 control subjects and measured the extent of the area with significant hypoperfusion(p<0.01) in predefined 34 cerebral regions. Only on area of left temporal lobe showed significant hypoperfusion in ADHD patients without comorbidity (n=75) compared with control subjects(n=13). (n=75, p<0.01, extent threshold=16). rCBF of left temporal area was ...
High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions can be quantitatively evaluated thermoluminescent dosimeter (TLD) chips with a dimension of 1/8 and film dosimetry with a spatial resolution of <1 mm used to measure the radiation ...
Sixty-three subjects, aged 6 months to 16 years, who were enrolled in a prospective, fully blinded, randomized parallel-group phase III clinical trial, received 0.1 mmol/kg doses of either Gd-BOPTA (n=29) or Gd-DTPA (n=34). The MR images were acquired before and within 10 min of contrast agent injection. The primary objective was to compare the difference from pre-dose to post-dose lesion visualization between Gd-BOPTA and Gd-DTPA. Lesion visualization was determined as the sum of individual scores for three criteria of lesion morphological characteristics (lesion border delineation, internal morphology, and contrast enhancement), each assessed qualitatively using 4-point scales. Quantitative evaluation compared changes in lesion-to-background (LBR) and contrast-to-noise (CNR) ratios and per cent enhancement. Monitoring for adverse events and evaluation of vital signs and laboratory values was performed. Pre-dose to post-dose changes in lesion ...
Image enhancement is of great importance in medical imaging where image resolution remains a crucial point in many image analysis algorithms. In this paper, we investigate brain hallucination...Full Text Available
Relationship between hemodynamic response to exercise and distribution of pulmonary perfusion was studied in 71 patients with mitral stenosis. Distribution was estimated by using computerized Tc-99m-MAA perfusion images (digital perfusion images; DPI). DPI were composed of isocount areas. Various types of DPI were obtained and were classified to 6 grades (G) according to patterns of 100 - 70% isocount area in right anterior DPI, i.e. G-0 (normal), G-1 (increase of perfusion at upper zone), G-2 (uniform distribution), G-3 (disappearance of basal hyperperfusion area), G-4 (apical hyperperfusion area) and G-5 (decrease of perfusion at lower zone). Patients were devided to 4 groups according to grade. At rest there were no marked hemodynamic differences between groups (n = 71, mean pulmonary artery pressure (mPA); 24.8 +- 11.0 mmHg, cardiac index (CI); 2.7 +- 0.81 lmM/sup 2/), however hemodynamic parameter during exercise ...
We present ultraviolet through far-infrared (FIR) surface brightness profiles for the 75 galaxies in the Spitzer Infrared Nearby Galaxies Survey (SINGS). The imagery used to measure the profiles includes Galaxy Evolution Explorer UV data, optical images from Kitt Peak National Observatory, Cerro Tololo Inter-American Observatory, and Sloan Digital Sky Survey, near-IR data from Two Micron All Sky Survey, and mid- and FIR images from Spitzer. Along with the radial profiles, we also provide multi-wavelength asymptotic magnitudes and several nonparametric indicators of galaxy morphology: the concentration index (C 42), the asymmetry (A), the Gini coefficient (G), and the normalized second-order moment of the brightest 20% of the galaxy's flux (M-bar20). In this paper, the first of a series, we describe the technical aspects regarding the surface photometry, and present a basic analysis of the global and structural properties of ...
Purpose: Three-dimensional rotational angiography (3DRA) is a new technique based on a rotational angiographic acquisition able to display arterial vessels in a 3D rendering mode. The system was mainly developed for neuroradiological evaluations but preliminary extracranial experiences have also been reported. The aim of our work was to compare the results of three-dimensional angiography of the carotid arteries done with high-flow injection of contrast medium from the aortic arch with the results of selective angiography. Materials and methods: Twenty patients underwent digital angiography of the supra-aortic vessels in order to quantify a stenosis of the carotid bifurcations previously detected at Doppler Ultrasound. Examinations were performed with the Philips Integris Allura system provided with the rotational angiography (RA) tool connected to a workstation for three-dimensional reconstruction able to display vessels in a 3D fashion (Volume Rendering, Shaded ...
Background: In an effort to standardise radiological practices in the Republic of Ireland, current legislation states that 'written protocols for every type of standard radiological practice shall be established'. In order to fulfil this requirement the Irish Medical Council recommends the protocols issued by the Commission of European Communitees (CEC) for adoption in the country. Whilst this document does provide good guidance with regard to various radiographic factors, patient shielding instructions are notably ambiguous. The aim of this study was to remove some of this ambiguity by defining the optimal method of positioning patient shielding in antero-posterior (AP) and lateral lumbar spine radiographic examinations. These projections were chosen on the basis of their area of coverage being in close to and in some cases including the reproductive organs. They also represent the highest source of collective population dose of any conventional radiographic ...
Background: In an effort to standardise radiological practices in the Republic of Ireland, current legislation states that 'written protocols for every type of standard radiological practice shall be established'. In order to fulfil this requirement the Irish Medical Council recommends the protocols issued by the Commission of European Communitees (CEC) for adoption in the country. Whilst this document does provide good guidance with regard to various radiographic factors, patient shielding instructions are notably ambiguous. The aim of this study was to remove some of this ambiguity by defining the optimal method of positioning patient shielding in antero-posterior (AP) and lateral lumbar spine radiographic examinations. These projections were chosen on the basis of their area of coverage being in close to and in some cases including the reproductive organs. They also represent the highest source of collective population dose of any conventional radiographic examination carried out in ...
The aim of this study was to determine sensitivity and specificity of magnetic resonance angiography (MRA) for the assessment of durable occlusion of intracranial aneurysms with Guglielmi detachable coils (GDC) and to point out the influence of MRA results in re-intervention strategies. Forty-five patients with 54 aneurysms that were previously treated by endovascular occlusion with GDC were selected for this study. All patients underwent digital subtraction angiography (DSA) and MRA examinations on the same day. The time-of-flight MRA studies were performed on a 1-T scanner. The MRA images were first read by radiologists who were not aware of the DSA results. In a second consensus reading by the neuroradiologists who had performed all interventional procedures of this series, the decision was made as to whether re-treatment was necessary. The distribution of aneurysm sizes, configurations and treatment results were sufficient for an unbiased ...
The implementation of a three-dimensional conformal radiotherapy facility in the radiotherapy department of the Heinrich Heine University is described. Complex radiotherapy techniques with commercially available networked systems are introduced to improve clinical work. Over 18 month we have gained clinical experience with a PHILIPS Multileaf Collimator (MLC) mounted on a SL 25 linear accelerator. For a limited period the MLC was used as a conventional blocking device. The standard MLC-shapes are controlled with a stand-alone computer system. In addition, a three-dimensional treatment planning system (3-D-TPS / TMS-Radix, Helax AB) based on convolution/superposition algorithms was recently installed. Treatment optimization is achieved using static field arrangements with complete volumetric computerized tomographic patient data for 3-D-TPS. Conformal adaptation of the 95%-isodose to the Planning Target Volume (PTV, ICRU 50) results in MLC-field-shaping concerning size, position and ...
Gabal Ralal is one of the major asymmetrical doubly- plunging anticlinal fold belts (50 Km length) related to the Syrian Arc System in northern Sinai, Egypt. The exposed rock units at Gabal Ralal range from Cretaceous to Quaternary and are divided into eight formations which are from base to top: Malha, Ralal, Wata, Themed, Sudr, Beida, Egma and Quaternary wadi deposits. The image processing is applied using Landsat-7 satellite data to discriminate structure and lithology for defining the horizons of the radioactive anomalies of each rock unit. The extracted structural lineaments, using Ge Analyst-PCl package, from digital ETM data showed that the main structural trends are NE-SW and NW-SE normal faults which originated as extensional fractures with lateral dip-slip displacement. The axial trace of Gabal Ralal fold is curved and plunging to Wand SW directions while the northeastern part (Gabal Dalfa) is plunging to NE direction. The use of ...
The biological literature is huge and increasingly moving to electronic form. By developing a variety of new techniques, it should be possible to take advantage of this huge and growing electronic store. Computers should allow one to use the literature with greater efficiency and insight to disseminate information and to advance scientific understanding. Though there is a great deal of research and development effort focused on electronic text, e.g., the Digital Libraries initiative, little attention has been paid to the diagrammatic content of documents. However, it is common knowledge among biologists, and scientists in general, that the figures in documents are of critical importance. Little work has been done to develop principles and systems for analyzing, representing, and indexing and searching the diagrammatic content of electronic documents. This has been the main thrust of this research project. The primary work in the world on the analysis of graphics in ...
This paper describes the design of a test rig, which is used to apply a representative pressure load to a full-scale composite sandwich secondary aircraft structure. A generic panel was designed with features to represent those in the composite sandwich secondary aircraft structure. To provide full-field strain data from the panels, the test rig was designed for use with optical measurement techniques such as thermoelastic stress analysis (TSA) and digitalimage correlation (DIC). TSA requires a cyclic load to be applied to a structure for the measurement of the strain state; therefore, the test rig has been designed to be mounted on a standard servo-hydraulic test machine. As both TSA and DIC require an uninterrupted view of the surface of the test panel, an important consideration in the design is facilitating the optical access for the two techniques. To aid the test rig design a finite element (FE) model was produced. The model provides ...
The methodology of achieving a high power density (HPD, or brake mean effective pressure) direct-injection Diesel engine has been studied, which is directed to using high fuel/air ratio, high-speed and ceramic engine components. Among the main thrust to achieve these engine changes for an advanced Diesel engine is the design of a high injection pressure (HIP) fuel system. During the course of the present study, two Cummins 903 engines mated with a Rutger-built HIP were employed to investigate the engine response to HIP and in-cylinder processes by using the Rutgers high-speed infrared (IR) spectral digitalimaging system. Five separate technical publications were prepared to report results obtained from the study. The main findings include: The HIP system permits engine operation at an air/fuel ratio of as rich as 18 to 1 with smoke emission not worse than with the conventional mechanical (low pressure) injection system; A high injection ...
Introduction: The goal of this study was to compare contrast-enhanced T1-weighted Flash and Turbo-Flash sequences with conventional spin-echo sequences as a basis for planning high-precision radiotherapy. Methods: A total of 25 consecutive patients with different intracranial tumors and a disrupted blood-brain barrier were studied. T1-weighted Flash, Turbo-Flash and conventional spin-echo images were evaluated after controlled 30-s infusion of 0.1 mmol/kg body weight of Gd-DTPA. The evaluation of the three sequences included the measurement of the signal- and contrast-to-noise ratios, the visual inspection of the tumors and artifacts, and the measurement of tumor size. Results: The signal- and contrast-to-noise ratios were significantly (P<0.05-0.01) lower for Flash and Turbo-Flash than for conventional spin-echo sequences. However, visual inspection of the contrast-enhancing tumors revealed in 23 and 24 of 25 lesions of Flash and Turbo-Flash ...
A previous paper introduced the use of wave digital filters as a basic building block for power system simulation, particularly suitable for real-time applications. This paper stresses the simulation of non-linear and switching elements, emphasizing the advantages of the wave filters implementation. The digital structure is maintained even when non-linear components change their characteristics or power electronic devices switch their states. As a very important by-product, the suppression of numerical oscillations related to the trapezoidal rule is achieved in a rather simple way, with no effects on simulation results.
and Vendors on the Web Bartleby.com "Great books online." Electronic Texts & Digital Libraries Links to the full text of books and other texts on the Web. Law and Politics...
of the digital hearing aid technology that led to the cochlear implant. Former. Marshall Space Flight Center engineers. John Richardson and Joseph Howard ...
Apr 9, 2003 ... Adam Kissiah Jr., a retired KSC engineer, will be honored for his development of the digital hearing aid technology that led to the cochlear ...
evaluation, novelty detection, resource discovery, interfaces and visualization, digital libraries, computational social science, and cross-lingual information retrieval. The CIIR...
A method for the determination of stereotaxic coordinates in radiography, e.g. angiography, pneumoencephalography or digital vascular radiography, is described. A special localization frame containing radiopaque structures and scales defines a diagnostic coordinate system. This frame is fixed to the X-ray-table prior to the radiographic procedure and two projections are obtained at arbitrary angles to each other. The focus-film distances do not have to be fixed. The target coordinates are then determined either by a simple graphical procedure or with the use of a digitizing x-y-table, by a computer. With the computer method the films are placed on the digitizing table and the target and a few reference points are marked using a cursor. From the relative positions the computer calculates the coordinates. With the special head fixation system, coordinates of structures visualized in radiographic examinations can be ...
Background/Objectives:Imaging technology is an important part of the diagnosis and management of spinal trauma. Indications and findings in post-traumatic imaging of the vertebral...Full Text Available
performs Gaussian pyramid operation on an image performs expand pyramid operation on an image mosaic two images using 'reduce' and 'expand' pyramid ...
This report describes the design of, and image reconstruction capacity of a Hadamard Raman Microscopic imager. Microscopy of benzoic acid and graphite electrodes, as well as electrophoretic blotting, are described. (CBS)
Widespread use of audio in computer-based training (CBT) occurred with the advent of the interactive videodisc technology. This paper discusses the alternative of digital audio, which, unlike videodisc audio, enables one to rapidly revise the audio used in the CBT and which may be used in nonvideo CBT applications as well. We also discuss techniques used in audio script writing, editing, and production. Results from evaluations indicate a high degree of user satisfaction. 4 refs.
This document contains papers which were presented at the First ACM International Conference on Digital Libraries. Topics processed for this document included information retrieval and index structures for structured documents. Individual papers have been processed separately for the United States Department of Energy databases.
From nuclear science symposium; San Francisco, California, USA (14 Nov 1973). A digital Fourier analyzer was programmed to perform reactor neutron noise analysis measurements and on-line processing of the data to obtain the steady-state reactivity. The system is suitable for recovering cross spectral density with low correlatedsignal component and for repetitive measurements with efficient use of reactor time. (auth)
Stabilization of the particle beam position with respect to the focusing optics in the third generation synchrotron light sources is crucial to achieving low emittance and high brightness. For this purpose, global and local beam orbit correction feedbacks will be implemented in the APS storage ring. In this article, the authors discuss application of digital signal processing to particle/photon beam position feedback using the PID (proportional, integral, and derivative) control algorithm.
Digital optical processing (DOP) was conceived to encompass the advantages of both electronic and optical processors, which are parallelism, flexibility, and high accuracy. The authors discuss the concept of parallelism, how it applies to DOP differently than to electronic parallel processing, and other potential advantages in using DOP. A PLZT memory device is described which can perform a series of logic or memory operations. From several of these PLZT devices a DOP is constructed to illustrate some of its programmability features.
We present an approach to automatically generate interfaces supporting personalized interaction with digital libraries; these interfaces augment the user-DL dialog by empowering the user to (optionally) supply out-of-turn information during an interaction, flatten or restructure the dialog, and enquire about dialog options. Interfaces generated using this approach for CITIDEL are described.
The design characteristic of the autocontrol technique of the combined centrifuge is introduced. Digital technique, vary structure control and interface technique, graphical display techniques, digital communication technique as well as electronic technique are applied in the course of research. Automation in the operation of large scale combined centrifuges and the course of combined test has been realized and it can coordinate with other systems of status monitoring, data collecting and centrifugal force-aerodynamic force matched load automatically
A new era for the field of Galactic structure is about to be opened with the advent of wide-area digital sky surveys. In this article, the author reviews the status and prospects for research for 3 new ground-based surveys: the Sloan Digital Sky Survey (SDSS), the Deep Near-Infrared Survey of the Southern Sky (DENIS) and the Two Micron AU Sky Survey (2MASS). These surveys will permit detailed studies of Galactic structure and stellar populations in the Galaxy with unprecedented detail. Extracting the information, however, will be challenging.
We propose new method of assessment of histological images for medical diagnostics. 2-D image is preprocessed to form 1-D landscapes or 1-D signature of the image contour and then their complexity is...Full Text Available
In vivo two-photon imaging through the pupil of the primate eye has the potential to become a useful tool for functional imaging of the retina. Two-photon excited fluorescence images...Full Text Available
Adaptive image processing is one of the most important techniques in visual information processing, especially in early vision such as image restoration, filtering, enhancement, and segmentation. This work focuses on applications of advanced CI techniques in image processing applications
Modeling artificial scanning electron microscope (SEM) and scanning ion microscope images has recently become important. This is because of the need to provide repeatable images with a priori determined parameters. Modeled artificial images are highly useful in the evaluation of new imaging and metrological techniques, like image-sharpness calculation, or drift-corrected image composition (DCIC). Originally, the NIST-developed artificial image generator was designed only to produce the SEM images of gold-on-carbon resolution sample for image-sharpness evaluation. Since then, the new improved version of the software was written in C++ programming language and is in the Public Domain. The current version of the software can generate arbitrary samples, any drift function, and many other features. This ...
Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula
Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula.
OBJECTIVETo assess the new quantitative bone scan parameters as markers of Charcot neuroosteoarthropathy (CNO) activity.RESEARCH DESIGN AND METHODSForty-two...Full Text Available
Emphasis was put on the comparative quantitative structure-activity approaches to the exploration of action mechanisms of structurally different classes of compounds showing the same type of activity...Full Text Available
Effective small interfering RNA (siRNA)–mediated therapeutics require the siRNA to be delivered into the cellular RNA-induced silencing complex (RISC). Quantitative information of this essential...Full Text Available
A single radial hemolysis test was developed for quantitation of specific antibody to non-hemagglutinating viruses. With the human coronaviruses as models, this test utilizes the binding properties...Full Text Available
We have exploited ``progeny testing'' to map quantitative trait loci (QTL) underlying the genetic variation of milk production in a selected dairy cattle population. A total of 1,518 sires, with progeny...Full Text Available
Gene expression data has been used in lieu of phenotype in both classical and quantitative genetic settings. These two disciplines have separate approaches to measuring and interpreting epistasis, which...Full Text Available
Deficits in prepulse inhibition (PPI) are a biological marker for schizophrenia. To unravel the mechanisms that control PPI, we performed quantitative trait loci (QTL) analysis on 1,010 F2 mice derived...Full Text Available
The Electronic REference To access In vivo Concentrations (ERETIC) method was applied to 1H HR-MAS spectroscopy. The accuracy, precision, and stability of ERETIC as a quantitative...Full Text Available
In this paper we argue that the set of wireless, mobile devices (e.g., portable telephones, tablet PCs, GPS navigators, media players) commonly used by human users enables the construction of what we term a digital ecosystem, i.e., an ecosystem constructed out of so-called digital organisms (see below), that can foster the development of novel distributed services. In this context, a human user equipped with his/her own mobile devices, can be though of as a digital organism (DO), a subsystem characterized by a set of peculiar features and resources it can offer to the rest of the ecosystem for use from its peer DOs. The internal organization of the DO must address issues of management of its own resources, including power consumption. Inside the DO and among DOs, peer-to-peer interaction mechanisms can be conveniently deployed to favor resource sharing and data dissemination. Throughout this paper, we show that most of the ...
The field of digital libraries (DLs) coalesced in 1994: the first digital library conferences were held that year, awareness of the World Wide Web was accelerating, and the National Science Foundation awarded $24 Million (U.S.) for the Digital Library Initiative (DLI). In this paper we examine the state of the DL domain after a decade of activity by applying social network analysis to the co-authorship network of the past ACM, IEEE, and joint ACM/IEEE digital library conferences. We base our analysis on a common binary undirectional network model to represent the co-authorship network, and from it we extract several established network measures. We also introduce a weighted directional network model to represent the co-authorship network, for which we define $AuthorRank$ as an indicator of the impact of an individual author in the network. The results are validated against conference program committee ...
Digital libraries play a crucial role in distance learning. Nowadays, they are one of the fundamental information sources for the students enrolled in this learning system. These libraries contain huge amount of instructional data (text, audio and video) offered by the distance learning program. Organization of the digital libraries is therefore very important for easy and fast access to the desired information. Improper categorization of data may mislead the students searching the library. Since manual categorization of huge amount of data might be challenging, an automatic and reliable method is needed. In this sense, this paper proposes an automated categorization scheme for digital libraries in distance learning. The categorization scheme is designed and developed by a pattern recognition approach. Effectiveness of the proposed scheme is evaluated on widely used Reuters database. The results of the ...
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm{sup -3} or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the end application itself ...
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm"-"3 or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the end application itself set ...
NIF target diagnostics are being developed to observe and measure the extreme physics of targets irradiated by the 192-beam laser. The response time of target materials can be on the order of 100ps--the time it takes light to travel 3 cm--temperatures more than 100 times hotter than the surface of the sun, and pressures that exceed 109 atmospheres. Optical and x-ray diagnostics were developed and fielded to observe and record the results of the first 4-beam experiments at NIF. Hard and soft x-ray spectra were measured, and time-integrated and gated x-ray images of hydrodynamics experiments were recorded. Optical diagnostics recorded backscatter from the target, and VISAR laser velocimetry measurements were taken of laser-shocked target surfaces. Additional diagnostics are being developed and commissioned to observe and diagnose ignition implosions, including various neutron and activation diagnostics. NIF's diagnostics are being developed at LLNL and with ...
The primary goal of this project is to increase the availability and ease of access to critical data on the Mesaverde and Dakota tight gas reservoirs of the San Juan Basin. Secondary goals include tuning well log interpretations through integration of core, water chemistry and production analysis data to help identify bypassed pay zones; increased knowledge of permeability ratios and how they affect well drainage and thus infill drilling plans; improved time-depth correlations through regional mapping of sonic logs; and improved understanding of the variability of formation waters within the basin through spatial analysis of water chemistry data. The project will collect, integrate, and analyze a variety of petrophysical and well data concerning the Mesaverde and Dakota reservoirs of the San Juan Basin, with particular emphasis on data available in the areas defined as tight gas areas for purpose of FERC. A relational, geo-referenced database (a geographic information system, or GIS) ...
After several years of planning and workshop meetings, a decision was reached in late 2008 to organize PICMG xTCA for Physics Technical Subcommittees to extend the ATCA and MTCA telecom standards for enhanced system performance, availability and interoperability for physics controls and applications hardware and software. Since formation in May-June 2009, the Hardware Technical Subcommittee has developed a number of ATCA, ARTM, AMC, MTCA and RTM extensions to be completed in mid-to-late 2010. The Software Technical Subcommittee is developing guidelines to promote interoperability of modules designed by industry and laboratories, in particular focusing on middleware and generic application interfaces such as Standard Process Model, Standard Device Model and Standard Hardware API. The paper describes the prototype design work completed by the lab-industry partners to date, the timeline for hardware releases to PICMG for approval, and the status of the software guidelines roadmap. The ...
Due to legal restrictions, the German hard coal mining company Deutsche Steinkohle AG (DSK) is obliged to conduct a monitoring on surface changes (subsidence) caused by mining activity (e.g. topographic surface, groundwater, water, flora and fauna, soil). To fulfill legal demands and to do this effectively, process chains by use of Photogrammetry, Remote Sensing and Geo-Informationssystems (GIS) have been established. Photogrammetric methods are used to generate high resolution Digital Elevation Models (DEM) from which in combination with subsidence data geometrical changes at the topographic surface are deduced. The potential use of active sensors (Laser Scanning and Synthetic Aperture Radar Systems) to deduct DEM has been investigated. The applicability of SAR satellite data to detect and observe subsidence and resulting movements - point wise or with spatial extent - using differential SAR Interferometry (dInSAR) as well as persistent scatterer technology (here: ...
On-orbit spectral calibration of hyperspectral imaging data is a key step for quantitatively analyzing them. Like the atmospheric correction, accurate spectral calibration is very necessary for improved studies of land or ocean surface properties. Based on the previous literatures, a new method which coupled an optimization algorithm was developed to simultaneously retrieve the central wavelength and the full width at half maximum (FWHM) of the hyperspectral sensor without needing the in situ reflectance spectra. Firstly, the Hyperion data set simulated using MODTRAN4 with the Hyperion spectral specification was used to test the new method, and the results indicated that the maximum error was less than 0.1 and 0.7 nm for central wavelength and FWHM respectively when the spectral shift is 5 nm. Then the algorithm was applied to the Hyperion data acquired on May 20, 2008 over Heihe River Basin and it was iteratively performed for each detector of ...
Part I of this thesis is on long-term iceberg collision-risk assessment methods for fixed offshore structures. Estimates for the long-term probability that an iceberg will hit a fixed offshore structure are based on estimates of the total volume of produced iceberg, a model for the size distribution of icebergs and a description of how iceberg trajectories ``fill`` the plane (the ocean`s surface). Part II of the thesis discusses methods for analysis of low resolution data in the sense that the size of the area covered by each pixel is not small compared to the dominating floes. Still, this type of data can provide estimates of the ice extent (and hence the ice edge) and ice concentration. The estimates of the ice edge (at least) seem to be physically significant in the sense that ``in some way`` they can reflect ice drift in an image time sequence. A priori this is far from obvious. A central idea is that the ``ice edge`` is close to a transition zone between two ...
Radioimmunotherapy (RIT) is a new treatment option for patients with non-Hodgkin lymphoma (NHL). Response to RIT currently remains difficult to predict using conventional prognostic factors and could be refined using functional imaging. The goal of this work is to evaluate the value of 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in predicting response to Yttrium 90-labeled monoclonal antibodies for patients with NHL. Thirty-five patients with NHL who had undergone 18F-FDG PET prior to RIT with either 90Y-ibritumomab tiuxetan (group A; n=17) or 90Y-epratuzumab tetraxetan (group B; n=18) were included in this retrospective study. Four functional criteria were determined for each tumour lesion in a given patient: maximum and mean standard uptake values (SUVmax and SUVmean), functional lesion volume (LVol) and total lesion glycolysis (TLG, product of the volume and the SUVmean). For each patient, we determined highest SUVmax and SUVmean, cumulative ...
Polycyclic aromatic hydrocarbons (PAHs) are combustion products of organic materials, mixtures of which contain multiple known and probable human carcinogens. PAHs occur in indoor and outdoor air, as well as in char-broiled meats and fish. Human exposure to PAHs occurs by inhalation, ingestion and topical absorption, and subsequently formed metabolites are either rendered hydrophilic and excreted, or bioactivated and bound to cellular macromolecules. The formation of PAH-DNA adducts (DNA binding products), considered a necessary step in PAH-initiated carcinogenesis, has been widely studied in experimental models and has been documented in human tissues. This review describes immunohistochemistry (IHC) studies, which reveal localization of PAH-DNA adducts in human tissues, and semi-quantify PAH-DNA adduct levels using the Automated Cellular Imaging System (ACIS). These studies have shown that PAH-DNA adducts concentrate in: basal and supra-basal epithelium of the ...
The detection and quantification of defined reaction products of chemical mutagens and carcinogens (and of many cancer chemotherapeutic agents) with DNA require highly sensitive analytical techniques. The exceptional capability of immunoglobulins to recognize subtle alterations of molecular structure (especially when monoclonal antibodies are used to maximize specificity), outstanding sensitivity of immunoanalysis by high-affinity antibodies, and the fact that radioactively-labelled agents are not required suggest the utility of a radioimmunoassay to recognize and quantitate alkylated DNA products. We have recently developed a set of high-affinity monoclonal antibodies (secreted by mouse x mouse as well as by rat x rat hybridomas; antibody affinity constants, 10"9 to > 10"1"0 lmol) specifically directed against several DNA alkylation products with possible relevance in relation to both mutagenesis and malignant transformation of mammalian cells. These alkylation ...
Based on their interesting properties, metal nanoparticles show the potential as an analytical tool in electronic (Burmeister et al. 2004), optical (Yguerabide and Yguerabide 1998), and catalytic applications (Liu 2006). Their characteristics depend on the composition, shape, and size of the single particles. These various properties are utilized in many different approaches such as optics, magnetics (Lang et al. 2007), and laser technology (Csaki et al. 2007). We investigated an alternative method for the synthesis of nanoparticles. In this case, an enzyme, horseradish peroxidase, induces a silver deposition and replaces a metal nanoparticle as the reaction seed. Depending on the reaction time, we could obtain particles in a range of few nanometers up to more than 250 nm. For a better understanding of the enzymatic silver deposition process, the silver particles produced by this process were analyzed by SEM, TEM, and atomic force microscopy (AFM) on a single particle level after ...
The object and the purpose of the present work was to develop, to assemble and to start running a new TOF (time of flight) mass spectrometer for imaging SNMS analytic which is optimized for the analysis of highly molecular secondary ions. The most important purpose was the characterization of the TOF mass spectrometer. The obtained mass spectra of indium, tantalum and silver clusters reflect the excellent properties of the TOF mass spectrometer for the detection of large clusters with good detection efficiency up to masses of 16000 amu. The possibility of the deflection of selected saturated atom and cluster peaks serves for further improvement of the detection efficiency for large molecules. The accessible mass resolution was determined to be of the order of m/{delta}m=1000 in the high mass region. Numerous measurements were carried out to characterize the useful yield of this spectrometer. For a best possible adaptation of the TOF mass spectrometer for the ...
Involvement of the dopaminergic system has been suggested in patients suffering from attention deficit hyperactivity disorder (ADHD) since the symptoms can be successfully treated with methylphenidate, a potent blocker of the dopamine transporter (DAT). This study reports the findings on the status of the DAT in adults with ADHD before and after commencement of treatment with methylphenidate, as measured using [{sup 99m}Tc]TRODAT-1. Seventeen patients (seven males, ten females, aged 21-64 years, mean 38 years) were examined before and after the initiation of methylphenidate treatment (3 x 5 mg/day). All subjects were injected with 800 MBq [{sup 99m}Tc]TRODAT-1 and imaged 3 h p.i. Single-photon emission tomography (SPET) scans were acquired using a triple-headed gamma camera. For semi-quantitative evaluation of the DAT, transverse slices corrected for attenuation were used to calculate specific binding in the striatum, with the cerebellum used ...
A review of current daylighting design tools indicates that over 30 tools are now available, including nomographs, protractors, overlays, and programs for micro-, mini-, and mainframe computers. Computer-based tools allow testing and analyzing of more design alternatives under a wider variety of conditions than was previously practical with slower techniques, but they have not fundamentally changed the information available to the design professional. These tools are applicable to certain limited functions of the design process and do not address the varying information needs of the designer at various points in the design process. We describe a concept for a computer-based building envelope design tool that is structured to overcome many of the limitations of the existing tools. The tool would address daylighting design in the context of the overall building envelope design, covering a range of environmental quality issues in addition to quantitative aspects of ...
Gamma scanning measurements are used to determine the radioactive nuclides from an irradiated fuel rod in a hot cell which is a routine task in the Irradiated Materials Examination Facility (IMEF) of the Korea Atomic Energy Research Institute (KAERI), Total gamma spectra of radioactive nuclides and the atomic ratio of {sup 134}Cs to {sup 137}Cs in a few segments of a single fuel rod are measured by the present gamma scanning system. For the purpose of determining the radioactive nuclide's distribution in detail within a fuel rod quantitatively, we attempt to upgrade the present gamma scanning system in this paper, therefore, an investigation of the feasibility of the tomographic gamma scanning (TGS) technique, which is one of the promising nondestructive assay (NDA) methods is proposed. The TGS technique is an efficient method and it has an accurate precision for the characterization of several fuel parameters. In this paper, a principle and an emission ...
The present research scholars are having keen interest in doing their research activities in the area of Data mining all over the world. Especially, [13]Mining Image data is the one of the essential features in this present scenario since image data plays vital role in every aspect of the system such as business for marketing, hospital for surgery, engineering for construction, Web for publication and so on. The other area in the Image mining system is the Content-Based Image Retrieval (CBIR) which performs retrieval based on the similarity defined in terms of extracted features with more objectiveness. The drawback in CBIR is the features of the query image alone are considered. Hence, a new technique called Image retrieval based on optimum clusters is proposed for improving user interaction with image retrieval systems by fully exploiting ...
For many years, {beta} radioactivity has been used to label molecules and follow them in various biological processes. {beta} imaging is obtained by autoradiography. Classically made on films or on photographic emulsions, autoradiography is now supplanted by radio-imagers which are very performing. The phosphor-imager, {beta}-imager and {mu}-imager are the systems mainly used today and their operating principles and properties are compared. The great advantages of these imagers are: their rapidity to obtain results and their reliability for absolute quantification. All emitters ({beta}{sup -}, {beta}{sup -} -{gamma} and {beta}{sup +}) are detectable as well as the gamma emitters of nuclear medicine, by means of their low energy electrons ejected during y emission. Phosphor-imager is well suited to energetic tracers and large series of ...
Over three years ago, the Core Integration team of the National Science Digital Library (NSDL) implemented a digital library based on metadata aggregation using Dublin Core and OAI-PMH. The initial expectation was that such low-barrier technologies would be relatively easy to automate and administer. While this architectural choice permitted rapid deployment of a production NSDL, our three years of experience have contradicted our original expectations of easy automation and low people cost. We have learned that alleged "low-barrier" standards are often harder to deploy than expected. In this paper we report on this experience and comment on the general cost, the functionality, and the ultimate effectiveness of this architecture.
Landscapes are both a synthesis and an expression of national, regional and local cultural heritages. It is therefore very important to develop techniques aimed at cataloguing and archiving their forms. This paper discusses the LDL (Landscape Digital Library) project, a Web accessible database that can present the landscapes of a territory with documentary evidence in a new format and from a new perspective. The method was tested in a case study area of the river Po valley (Northern Italy). The LDL is based on a collection of photographs taken following a systematic grid of survey points identified through topographic cartography; the camera level is that of the human eye. This methodology leads to an innovative landscape archive that differs from surveys carried out through aerial photographs or campaigns aimed at selecting "relevant" points of interest. Further developments and possible uses of the LDL are also discussed.
Explicitly defining virtual collections in a digital library can benefit both users and contributors. This paper outlines the costs and benefits for defining virtual collections and describes an implementation of collection-level metadata in two digital libraries. Our work suggests that component repositories of NSDL would profit by describing their collection, and sub-collections, using a schema such as the one we implemented. This would enable NSDL to provide a rich, cross-linked hierarchy of virtual collections. By sharing collection-level, rather than item-level, metadata, collections would provide detailed resource information, presumably keeping most of their viewership, while NSDL would provide a broad description of resources.
Digital topographic models are the foundation of more advanced modeling applications and ultimately inform planning and decision making in many fields. Despite this, the error associated with these models and derived attributes is commonly overlooked. Little attention has been given in the scientific literature to the benefits gained from having less error in a model or to the corresponding cost associated with reducing model error by choosing one product over another. To address these gaps in knowledge we evaluated the error associated with five digital elevation models (DEMs) and derived attributes of slope and aspect relative to the same attributes derived from LiDAR data. We also estimated the acquisition and processing costs per square kilometer of the five test models and the LiDAR m...
Purpose - The purpose of this paper is to encourage other libraries to provide access to their own original content via the web. By way of case study, the process of identifying materials, scanning them and creating web access to original content will be explored. Design/methodology/approach - To implement a book digitization project, three major things need to be present. The library must own material that was published prior to 1923, making them safely out of copyright in the USA; the library needs access to server space on the web and the library needs to own scanning equipment. Findings - This project demonstrated that a library does not necessarily need to obtain grant funding to begin an effective and successful digitization program. It also revealed a few things that would improve t...
Two geriatic male rhesus monkeys were used for the radioisotope imaging in this research. Discussion of the radionuclide, materials, and method used to accomplish the neurologic examination and the results obtained, both during the procedure and confirmation of the results by necropsies were accompanied by color photos of scan images. Results were that the nuclear images provided accurate images of intracranial neoplasia.
This paper examines the seismic signatures of discrete, finite-length fractures, and outlines an approach for elastic, prestack reverse-time imaging of discrete fractures. The results of this study highlight the importance of incorporating fracture-generated P-S converted waves into the imaging method, and presents an alternate imaging condition that can be used in elastic reverse-time imaging when a direct wave is recorded (e.g., for crosswell and VSP acquisition geometries).
In this two chapter report, instrumentation used to collect seismic data is described. This data acquisition system has two parts: (1) portable anolog seismic recorders and related ``hand-held-testers`` (HHT) and (2) portable digitizing units. During the anolog recording process, ground motion is sensed by a 2-Hz vertical-component seismometer. The voltage output from the seismometer is split without amplification and sent to three parallel amplifier circuit boards. Each circuit board amplifiers the seismic signal in three stages and then frequency modulates the signal. Amplification at the last two stages can be set by the user. An internal precision clock signal is also frequency modulated. The three data carrier frequencies, the clock carrier frequency, and a tape-speed compensation carrier frequency are summed and recorded on a recorded on a cassette tape. During the digitizing process, the cassette tapes are played back and the signals are ...
Apr 20, 2009 ... "YY" is the 2-digit filter identifier .... In our example you can see a point- like optical/UV source in each of the filters at the ... The "sigma" paramter gives the detection threshold in terms of Gaussian sigma. ...
Destress blasting is commonly used as a stress control technique at the Galena Mine, Wallace, Idaho, where the U.S. Bureau of Mines maintains a cooperative research program with the mine operators (ASARCO). A digital seismic array and an array of borehole...
In addition, for breast cancer, a fifth field, Reconstruction--First Course is recorded. V.02.E Reconstruction--First Course (breast only) 1 digit These codes for these fields are included as Appendix C of this manual.
Digital information flow within the intensive care unit (ICU) continues to grow, with advances in technology and computational biology. Recent developments in the integration and archiving of these...Full Text Available
This article reviews briefly a range of the latest monitoring and controlling equipment for use in coal mines. This includes pressure transmitters, shale/coal discriminator, nucleonic bunker level indicator, automatic steering and monitoring system, oscilloscope/multimeter, and microprocessor based digital display controllers. 1 fig.
Purpose: The present research aims to identify the difficulties and obstacles for developing digital libraries in the seven regional branches of Islamic Azad University (IAU), Iran, and to study the status of librarians' skills and education programmes at these institutions. Design/methodology/approach: The 40 individuals working in the regional branch libraries of IAU were surveyed by a questionnaire consisting of 34 questions, and the collected data were analysed using SPSS software (version 16). Findings: It was found that the most important difficulties are the lack of suitable equipment and untrained personnel (i.e. a lack of sufficient training programmes). Research limitations/implications: Because of the small number of participants, it is suggested that a larger scale study is carried out. It is also proposed that the suggestions made by the participants will be considered and implemented, based on the digital library (DL) developments ...
Abstract: Data currently available in the Ontario Timber Inventory include Canada ... Download 1:250 000 scale Ontario Timber Inventory data in Arc Export ...
The behavior of a small power system consisting of two interconnected generators is simulated in real-time by a prototype Digital Transient Network Analyzer (TNA). The prototype Digital TNA consists of two Computational Modules and one I/O Module. The Modules communicate with each other through ribbon cables. Each Computational Module simulates one Turbo-Generator, its Transformer, its Governor, Exciter, and Power System Stabilizer Systems. The numerical integration is shared by two TMS320C30 DSPs at a step-size of 100 microseconds in real-time. The I/O module post-processes the state variables and presents selected information for analog display. The paper presents oscillograms from a test program which includes symmetry checks and behavioral checks against well known waveforms of hunting oscillations, synchronization out-of-phase torques, and subsynchronous resonance phenomena. The success of the Digital TNA depends on: ...
This talk sketches out the main parameters (technology, circuit design) that have an influence on the hardening of digital CMOS integrated circuits. For each technology the more common defects are mentioned. General design rules are proposed to prevent or limit those defects. (D.L.). 2 refs., 2 figs.
Ever-changing audio technology requires that National Library Service NLS always be aware of developments and prepare carefully for any systematic changes that may be desired or required. Usefulness, cost effectiveness, thoughtful stewardship, and educate...
A new method for removing periodic background patterns from pictures is presented. The basic spatial frequency composition of the pattern is determined from an estimate of the power spectrum of the picture. A digital restoration filter is then created from a modified version of the power spectrum. The method is extremely effective and can be automated.
Since the PWR plants in Japan have been operated more than 30 years, main instrumentation control equipment of analog systems has been renewed to digital control systems. Renewal works had to be done in short period within periodical inspection term and for several facilities. The Mitsubishi LTD group had been provided with these market needs by its digital control system (MELTAC-NplusR 3) applicable to main instrumentation control equipment for primary and secondary systems and had already finished the renewal for practical plants. (T. Tanaka)
Information glut is one of the primary characteristics of the electronic age. Managing such large volumes of information (e.g., keeping track of the types, where they are, their relationships, who controls them, etc.) can be done efficiently with an intelligent, user-oriented information management system. The purpose of this paper is to describe a concept for managing information resources based on an intelligent information technology system developed by the Argonne National Laboratory for managing digital libraries. The Argonne system, Intelligent Query (IQ), enables users to query digital libraries and view the holdings that match the query from different perspectives.
The design of High-Voltage, Direct-Current transmission cables insulated with oil-impregnated cellulose paper is constrained by the maximum temperature and the maximum steady-state and transient stresses (voltage gradients) that the cable insulation can reliably withstand over the desired operating lifetime. Because the electrical stresses in the insulation are related in a very complex fashion to temperature, applied voltage and cable geometry, iterative techniques are required to compute the values of these stresses. Digital computers are ideally suited for these iterative techniques. This paper presents the principal equations and logic needed to develop suitable computer programs.
A typical incident response pits technicians against networks that aren't prepared forensically. [1, 2] If practitioners do consider collecting network forensic data, they face a choice between expending extraordinary effort (time and money) collecting forensically sound data, or simply restoring the network as quickly as possible. In this context, the concept of organizational network forensic readiness has emerged. This paper proposes a methodology for "operationalizing" organizational network forensic readiness. The methodology, and the theoretical analysis that led to its development, are offered as a conceptual framework for thinking about more efficient, proactive approaches to digital forensics on networks.
A register transfer language is used to present the basic concepts of computer hardware architecture. Material needed for understanding computer organisation, design, and programming is included. The various functional units of digital computers (central processor, microprogram control; arithmetic algorithms; input-output; and memory organisation), are examined. A basic computer is developed to demonstrate the components of computer hardware and software architecture. Parallel processing and multiprocessor systems are discussed. Numerous MSI and LSI digital functions are introduced with explanations of their characteristics. Cache memory and the hardware requirements for a memory management unit are covered.
Use of a broadband Local Area Network (LAN) for transmission of classified and secure unclassified information requires monitoring capabilities which are sensitive to discrete segments of the network frequency spectrum. A viable monitoring system must be capable of detecting possible intrusion attempts or network malfunctions and alerting operating and security personnel. This report documents the results of an evaluation of the Magnavox CATV Systems Inc. Digital System Sentry software for network monitoring. Recommendations are made on its possible future role in broadband LAN security monitoring throughout the Nuclear Weapons Complex.
Energy and angular double-differential cross-section (DDX) data of fragment production reactions by neutrons or protons are very scarce due to experimental difficulties of fragment detection. We adopted a Bragg curve spectrometer (BCS), which is a gridded-ionization chamber that can identify fragments on the basis of the Bragg peak value. We have been developing the BCS for neutron and proton-induced reactions applying the digital waveform analysis technique to obtain better ability of particle discrimination than the analog electronic circuit. (T. Tanaka)
The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available
This paper discusses the clinical application and main objective of testicular imaging. The authors present cases that represent a spectrum of the abnormalities which might be detected by testicular imaging, with special attention given to testicular torsion and the acute diseases which may mimic it clinically. Accuracy of the test is noted.
Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. One key component of 4D radiotherapy planning...Full Text Available
PurposeAuto-propagation of anatomical region-of-interests (ROIs) from the planning CT to daily CT is an essential step in image-guided adaptive radiotherapy. The...Full Text Available
This paper proposes a novel method for computing linear basis images from tensor-valued image data. As a generalization of the nonnegative matrix factorization, the proposed method aims to approximate...Full Text Available
A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.
Multimodality imaging with PET/CT and SPECT/CT has become commonplace in clinical practice and in preclinical and basic medical research. Do other combinations of imaging modalities have a similar...Full Text Available
Purpose: Small animal micro-CT imaging is being used increasingly in preclinical biomedical research to provide phenotypic descriptions of genomic models. Most of this imaging is coincident...Full Text Available
Epifluorescence images of Ca2+ transients elicited by electrical stimulation of single skeletal muscle fibers were studied with fast imaging techniques that take advantage of the large fluorescence...Full Text Available
Optical coherence microscopy (OCM) is a promising technique or high resolution cellular imaging in human tissues. An OCM system for high-speed en face cellular resolution imaging...Full Text Available
This multiauthored text is aimed particularly toward the resident or registrar training in diagnostic radiology. This is a text book on the entire scope of diagnostic imaging. It includes techniques and imaging modalities of all the systems, head, face and neck. The book covers the entire gamut of diagnostic radiology.
Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final...Full Text Available
Image registrations that are based on similarity measures simply adjust the parameters of an appropriate spatial transformation model until the similarity measure reaches an optimum. The numerous similarity measures that have been proposed in the past are differently sensitive to imaging modality, image content and differences in the image content, selection of the floating and target image, partial image overlap, etc. In this paper, we evaluate and compare 12 similarity measures for the rigid registration. To study the impact of different imaging modalities on the behavior of similarity measures, we have used 16 CT/MR and 6 PET/MR image pairs with known 'gold standard' registrations. The results for the PET/MR registration and for the registration of CT to both rectified and unrectified MR ...
An image slicing spectrometer (ISS) for microscopy applications is presented. Its principle is based on the redirecting of image zones by specially organized thin mirrors within a custom fabricated...Full Text Available
ObjectiveThis study was conducted to evaluate a computer-imaging program called HAAIR (Help with Adjustment to Alopecia by Image Recovery) that was developed to provide...Full Text Available
Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available
Post-mortem magnetic resonance (MR) imaging is of increasing interest not only as an alternative to autopsy but as a research tool to aid the interpretation and diagnosis of in utero MR images. The information from the post-mortem MR has allowed the development of imaging sequences applicable to in utero imaging and neonatal imaging. It has established brain development during gestation and has provided data on this to which in utero MR can be compared. The detail available from the post-mortem images is such that brain development can be studied in a non-invasive manner, a permanent record on the normal and abnormal areas is available and a greater understanding of developmental abnormalities is possible.
The central nervous system is involved in 10-20% of cases in Lyme disease. The neurological symptoms, time course of the disease and imaging findings are multifaceted. We report two patients with cervical radiculitis. Magnetic resonance imaging revealed strong enhancement of the cervical nerve roots on contrast-enhanced T1-weighted images. These imaging patterns of borrelia-associated radiculitis have not been reported before. Knowledge of these imaging features may help to diagnose neuroborreliosis, which presents with non-specific symptoms. (orig.)
Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)
Aug 25, 2004 ... The Tropical Rainfall Measuring Mission or TRMM satellite provided this image of Typhoon Aere over the western Philippine Sea as it was ...
Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available
Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available
Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy electron beam therapy. (author)
An image-analysis system, based on commercially available data visualization software (IDL [1]), allows convenient interaction with image data while still providing calculated beam parameters at a rate of up to 2 Hz. Image data are transferred from the IOC to the workstation via EPICS [2] channel access. A custom EPICS record was created in order to overcome the channel access limit of 16k bytes per array. The user can conveniently calibrate optical transition radiation (OTR) and fluorescent screens, capture background images, acquire and average a series of images, and specify several other filtering and viewing options. The images can be saved in either IDL format or APS-standard format (SDDS [3]), allowing for rapid postprocessing of image data by numerous other software tools.
This paper presents two imaging methods by using cross correlation. The one method images the subsurface by cross-correlation of the observed data and partial derivative seismograms calculated for a guessed model. The other method images the interface by use of cross-correlation of the virtual sources and the back propagated wave fields calculated from the observed data. Experimental tests show that both methods image subsurface interfaces well even if the guessed model is different from the true one. These imaging methods are reverse time migration that we perform cross-correlation as an imaging condition and have an advantage, as compared to conventional waveform inversion method, that images subsurface structure without iterative perturbation of the assumed model. (author). 18 refs., 15 figs.
Over the past decade, dramatic increases in computational power and improvement in image analysis algorithms have allowed the development of powerful computer-assisted analytical approaches...Full Text Available
AFFF has fabricated the (U, Pu)O_2 mixed oxide fuels for PHWRs, BWRs, PFBRs and FBTRs. The quantitative dissolution of the fuel samples are required within time for accurate determination of uranium-plutonium in chemical quality control laboratory. This paper describes the use of microwave heating technique in quantitative dissolution of (U, Pu)O_2 MOX (from 0.4% to 44% PuO_2). (author)
Objective: To determine the reproductibility of three-dimensional volume and thickness measurements of the knee joint cartilage with MRI in volunteers. Methods: The knees of 7 healthy individuals (ages 23 to 58 yrs.) were sagitally imaged with a resolution of 2x0.31x0.31 mm{sup 3}, using a fat-suppressed FLASH-3 D sequence. The knee was repositioned in between replicate acquisitions, 6 data sets being obtained in each case. After semiautomatic segmentation and three-dimensional reconstruction of the cartilage, the thickness was determined independent of the original section orientation. The coefficient of variation for repeated volume measurements and the deviations of the maximal cartilage thickness values were calculated subsequently. Results: The mean variation of the cartilage volumes of the replicate measurements was 1.4% ({+-}0.8%) in the patella, 1.7% ({+-}1.5%) in the femur, 3.0% ({+-}1.2%) in the medial tibial plateau and 3.5% ({+-}2.0%) in the lateral ...
Aim: There has been a great demand for developments of the radioligands to visualize the N-methyl-D-aspartate (NMDA) receptors by PET/SPECT. We have recently synthesized two C-11 labeled antagonists for the glycine-binding site on NMDA receptors. The aim of this work is to examine for their in vitro and in vivo binding characteristics, and to evaluate their potentials as PET radioligands for the NMDA receptors. Materials and methods: Two C-11 labeled 4-hydroxy-2-quinolones (1 and 2) were synthesized by conventional methylation of the corresponding phenols with ["1"1C]methyl iodide. In vitro and ex vivo quantitative autoradiographs with imaging plate, as well as animal PET, were employed in order to evaluate their in vitro and in vivo binding to the NMDA receptors. Results: The compound 1 showed the specific binding to rat brain slices with higher localization in the hippocampus and cerebral cortex than in the cerebellum. Both glycine ...
The three mammalian transforming growth factor (TGF)-? isoforms (TGF-?1, TGF-?2, and TGF-?3) differ in their putative roles in radiation-induced fibrosis in intestine and other organs. Furthermore, tissue specificity of TGF-? action may result from temporal or spatial changes in production and/or activation. The present study examined shifts in the cell types expressing TGF-? mRNA relative to TGF-? immunoreactivity and histopathological injury during radiation enteropathy development. A 4-cm loop of rat small intestine was locally exposed to 0, 12, or 21-Gy single doses of x-irradiation. Sham-irradiated and irradiated intestine were procured 2 and 26 weeks after irradiation. Cells expressing the TGF-?1, TGF-?2, or TGF-?3 transcripts were identified by in situ hybridization with digoxigenin-labeled riboprobes. Intestinal wall TGF-? immunoreactivity was measured using computerized image analysis, and structural radiation injury was assessed by ...
... These assumptions are quantitatively investigated by calculating tie icldti\\e inportance of ... A modified lon-shore current model is used to study the ...
A specific application of single photon emission tomography to the relative quantitation of the pituitary region is described together with the results obtained in 19 patients with pituitary adenoma...Full Text Available
BACKGROUND: An approach to the study of the pharmacokinetics of drugs in the lung is to measure their concentrations in bronchial biopsy specimens. The main criticism of this technique is that bronchial...Full Text Available
Abstract: The current financial crisis has now led most major central banks to rely on quantitative easing. The unique Japanese experience of quantitative easing is the only experience which enables us to judge this therapy's effectiveness and the timing of the exit strategy. In this paper, we provide a new empirical framework to examine the effectiveness of Japanese monetary policy during the ''lost'' decade and quantify the effect of quantitative easing on Japan's activity and prices. We combine advantages of Markov-switching VAR methodology with those of factor analysis to establish two major findings. First, we show that the decisive change in regime occurred in two steps: it crept out from late 1995 and established itself durably in February 1999. Second, we show for the first time th...
Absolute measurements of cerebral blood flow (CBF) are an important endpoint in studies of cerebral pathophysiology. Currently no accepted method exists for in vivo longitudinal...Full Text Available
... and high-quality photospheric-phase Type II SN spectra to constrain core- collapse SN explosions, massive star evolution, and distances in the Universe ...
OBJECTIVEEvaluate the qualitative and quantitative differences between moderated and unmoderated on-line social support groups focused on asthma.DESIGNA...Full Text Available
Computer-Aided Prediction of Chemical Ecotoxicity on the basis of Quantitative Structure-Activity Relationships with the Use of Physico-Chemical Descriptors, Including H-bond Parameters
AIM: To investigate the effects of gallbladder stones on motor functions of the gallbladder and the dynamics of bile flow in asymptomatic gallstone disease.METHODS: Quantitative hepatobiliary...Full Text Available
BackgroundSeveral fractal and non-fractal parameters have been considered for the quantitative assessment of the vascular architecture, using a variety of test specimens and of computational...Full Text Available
The concentration of apolipoproteins was measured by quantitative immunoelectrophoresis in rat serum, in the lipoprotein-free ultracentrifugal fraction (density greater than 1.21) of serum, and in renal...Full Text Available
In this model, without dark matter, the flat rotation curves of galaxies and the mass-to-light ratios of clusters of galaxies are described quantitatively. The hypothesis is that the agent of gravitational...Full Text Available