WorldWideScience
1

Integrated Coronary Physiology in Percutaneous Intervention: A new paradigm in interventional cardiology  

British Library Electronic Table of Contents (United Kingdom)

Coronary angiography has provided an unrivalled appreciation of coronary anatomy fostering a far greater appreciation of the extent of atherosclerotic disease. However, the subjectivity of coronary angiography at determining the extent of plaque has been exposed with IVUS. Indices of coronary physiology have provided valuable adjunctive information as to the physiological importance of specific lesions. Fractional flow reserve is an established method for evaluating the significance of epicardial stenoses. Fractional flow reserve guided percutaneous coronary intervention is associated with improved outcomes when compared to a conventional angiographic guided strategy, particularly in intermediate lesions. The use of coronary physiology in the cath lab represents a new avenue to guide appro...

2011-01-01

2

Correlation of myocardial TC-99m-MIBI perfusion SPECT with coronary angiography in Namazi hospital  

International Nuclear Information System (INIS)

Coronary heart disease is the leading cause of death specially among elderly. Coronary angiography is the best diagnostic method in the patients, but is unfortunately an invasive procedure with its inherent risks. Myocardial perfusion scan is a noninvasive and sensitive method for evaluation of Coronary artery disease and is suggested by many investigators in recent years. In this study, 64 patients who had a Tc99m-MIBI SPECT myocardial perfusion study at our department, underwent coronary angiography within 4 months. Correlation of the methods revealed that SPECT Tc99m -MIBI had a high sensitivity and specificity in our hand, which is comparable with international findings.

2004-04-27

3

Low-dose contrast protocol using the test bolus technique for 64-detector computed tomography coronary angiography  

British Library Electronic Table of Contents (United Kingdom)

Purpose We evaluated low-contrast injection protocols for coronary computed tomography angiography (CTA) using a 64-detector scanner and the test bolus technique. Materials and methods We randomly assigned 60 patients undergoing coronary CTA to one of two contrast material (CM) injection protocols. For the lowcontrast dose protocol (Plow), the patients received injections of iohexol-350 [0.7 ml/kg body weight (BW)] during 9 s, and the test-bolus technique was used. Under the conventional protocol (Pconv), they received iohexol-350 (1.0 ml/kg BW) during 15 s, and bolus tracking was used. We compared the protocols for attenuation values in the ascending aorta and coronary arteries and for the amount of CM required. Results There was no significant difference in the mean CT attenuation of the...

2011-01-01

4

Routine invasive management after fibrinolysis in patients with ST-elevation myocardial infarction: a systematic review of randomized clinical trials  

UK PubMed Central (United Kingdom)

BackgroundPatients with ST-elevation myocardial infarction (STEMI) treated with fibrinolysis are increasingly, and ever earlier, referred for routine coronary angiography and where...Full Text Available

5

Real-Time Assessment of Cardiac Perfusion, Coronary Angiography, and Acute Intravascular Thrombi Using Dual-Channel Near-Infrared Fluorescence Imaging  

UK PubMed Central (United Kingdom)

ObjectivesWe have developed an image-guided surgery system based on invisible near-infrared (NIR) fluorescent light. Presently, the only clinically-available NIR...Full Text Available

2009-07-01

6

Angina with a normal coronary angiogram caused by amyloidosis  

UK PubMed Central (United Kingdom)

A case of severe intractable angina pectoris with normal angiography is presented. Following video assisted thoracic sympathectomy the patient died of heart failure. Microvascular cardiac amyloidosis...Full Text Available

2004-09-01

7

Prenatal diagnosis and perinatal management of left coronary artery to right atrium fistula.  

Science.gov (United States)

Serious complications due to coronary artery fistulae have been described. Most authors recommend early intervention at the time of diagnosis. We present a case of a fistula originating from a dilated left coronary artery and draining into the right atrium, which was diagnosed prenatally by color Doppler echocardiography. During pregnancy, the echocardiographic findings remained unchanged, and there were no signs of heart failure. After birth, the fistula was confirmed by angiography. Additionally, a persistent left superior vena cava draining into the coronary sinus and a very small ventricular septal defect were detected. The fistula was closed successfully by transcatheter coil embolization. At 17 months old the child was in good clinical condition. Prenatal diagnosis of coronary artery fistulae may be possible and may improve perinatal management and outcome. PMID:12047543

2002-06-01

8

Body weight-tailored contrast material injection protocol for 64-detector row computed tomography coronary angiography  

International Nuclear Information System (INIS)

The aim of this study was to assess the body weight-tailored contrast material injection protocol for 64-detector computed tomography (CT) to maintain optimal coronary CT attenuation. A total of 60 patients who underwent CT coronary angiography were assigned to one of three groups: protocol A, total of 0.7 ml kg"-"1 with 300 mg I/ml iodine concentration; protocol B, total of 0.6 ml kg"-"1 with 350 mg I/ml; protocol C, total of 0.7 ml kg"-"1 with 350 mg I/ml. The injection duration was 10 s in all patients. The proportion of intracoronary attenuation values >325 Hounsfield unit (HU) was compared on a per-vessel and per-patient basis. The attenuation value was significantly more likely to exceed 325 HU with protocol C (95% for reader 1 and 90% for reader 2) than with protocol A or B on the per-vessel analysis (P325 HU) with 64-detector CT when using an injection duration of 10 s. (author)

2011-01-01

9

Should coronary angiography be the gold standard? A study correlating thallium myocardial scintigraphy, translesional pressure gradient and percent stenosis  

International Nuclear Information System (INIS)

Coronary angiography provides anatomical information whereas thellium myocardial scintigraphy measures resistive tissue perfusion. Because of this fundamental difference. The authors question the validity of using coronary angiography as the gold standard to judge thellium myocardial scintigraphy. The authors studied 20 patients undergoing elective percutaneous coronary angioplasty who fulfilled the following criteria: (1) history of chest pain; (2) angiographically significant single vessel disease (>50% stenosis); (3) no prior myocardial infarction. All patients underwent maximal exercise thallium single photon emission computed tomography (T1-SPECT). Tl-SPECT was scored visually according to a 0 to 3 scale (0=absent uptake; 1=markedly decreased uptake; 2=minimally decreased uptake; 3=normal uptake). Translesional gradient and percent stenosis were measured before and after ...

1985-06-02

10

Iopentol in cardioangiography  

International Nuclear Information System (INIS)

Iopentol (350 mg I/ml) has been compared with iohixol (350 mg I/ml) in a double-blind randomized parallel group trial with 32 and 35 patients receiving iopentol and iohexol, respectively. Coronary angiography and left ventriculography were performed, and the mean total volume injected was 124 ml of iopentol and 135 ml of iohexol . There were no statistically significant differences regarding changes in heart rate and frequency of adverse advents, which were the primary parameters, between the two groups of patients. Blood pressure and ECG parameters revealed only minor fluctuations which were of no clinical relevance. The visualization of the coronary arteries and the left ventricle were the same with both contrast media, as was the diagnostic quality. The results support the use of iopentol in cardioangiography. (author). 1 ref.; 5 tabs.

11

What is the best contrast injection protocol for 64-row multi-detector cardiac computed tomography?  

International Nuclear Information System (INIS)

Objective: To determine the optimal contrast injection protocol for 64-MDCT coronary angiography. Materials and methods: One hundred and fifty consecutive patients scheduled to undergo retrospectively electrocardiographically gated 64-MDCT. Each 30 patients were assigned to use a different contrast protocol: group 1: uniphasic protocol (contrast injection without saline flush); group 2: biphasic protocol (contrast injection with saline flush); group 3A, 3B and 3C: triphasic protocol (contrast media + different saline diluted contrast media + saline flush). Image quality scores and artifacts were compared and evaluated on both transaxial and three-dimensional coronary artery images among each contrast protocol. Results: Among the triphasic protocol groups, group 3A (30%:70% contrast media-saline mixture was used in second phase) used the least contrast media and had the least frequency of streak artifacts, but there were no ...

2010-08-01

13

The influence of different SPECT reconstruction algorithms on cardiac ischemia with the use artificial neural networks  

International Nuclear Information System (INIS)

The aim of the study was the attempt to evaluate the influence of two different methods of cardiac perfusion SPECT reconstruction (FBP and ITW) on clinical efficacy in diagnosing the coronary artery disease as well as the cardiac ischemia detection in three areas of heart vascularized by main coronary arteries: LAD, LCX and RCA with the use of artificial neural networks (ANN). The study was performed retrospectively with the use of the diagnostic image records as well as clinical dataset of 43 patients. Myocardial perfusion stress/rest SPECT study and X-ray coronarography data were evaluated for each patient. The results of coronary angiography were considered the reference method. The cardiac SPECT data were reconstructed using the two different methods: filtered backprojection (FBP) and iterative Wallis method (ITW). The local perfusion deficits denominated in stress and rest study in three main ...

14

64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to test a large sample of different coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in 64-slice multidetector-row computed tomography (MDCT) in vitro and to provide a catalogue of currently used coronary artery stents when imaged with state-of the-art MDCT. We examined 68 different coronary artery stents (57 stainless steel, four cobalt-chromium, one cobalt-alloy, two nitinol, four tantalum) in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70). Stents were imaged in axial orientation with standard parameters: 32x0.6 collimation, pitch 0.24, 680 mAs, 120 kV, rotation time 0.37 s. Four different image reconstructions were obtained with varying convolution kernels and section thicknesses: (1) soft, 0.6 mm, (2) soft, 0.75, (3) ...

2006-04-15

15

Usefulness of myocardial imaging by [sup 123]I-MIBG in assessment of diabetic neuropathy  

Energy Technology Data Exchange (ETDEWEB)

In diabetic patients with autonomic neuropathy, it is suggested that there is a reduced uptake of [sup 123]I-metaiodobenzylguanidine (MIBG) in the heart. We compared the difference of myocardial [sup 123]I-MIBG accumulation between 4 diabetic patients with triopathy and 6 patients without it. In all 10 patients, coronary angiography and [sup 201]Tl imaging (rest and 4 hours later) were performed. [sup 123]I-MIBG (111 MBq) was administered intravenously and its imaging was recorded on 15 minutes and 4 hours after injection. In all 4 cases with triopathy, [sup 123]I-MIBG imaging showed defect in apical and inferior region. In 2 out of 6 cases without triopathy, rapid clearance was noticed in apical and inferior region. There was no significant stenosis in right coronary artery and no defect in initial and delayed [sup 201]Tl images in all cases. We concluded that diabetic autonomic neuropathy in the heart was prominent in ...

1993-10-01

16

Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to evaluate imaging features of different coronary artery stents during multislice CT Angiography (MSCTA). Nineteen stents made of varying material (steel, nitinol, tantalum) and of varying stent design were implanted in plastic tubes with an inner diameter of 3 mm to simulate a coronary artery. The tubes were filled with iodinated contrast material diluted to 200 Hounsfield units (HU), closed at both ends and positioned in a plastic container filled with oil (-70 HU). The MSCT scans were obtained perpendicular to the stent axes (detector collimation 4 x 1 mm, table feed 2 mm/rotation, 300 mAs, 120 kV). Axial images and multiplanar reformations were evaluated regarding artifact size, lumen visibility, and intraluminal attenuation values. Artifacts characterized by artifactual thickening of the stent struts leading to apparent reduction in the lumen diameter and increased intraluminal attenuation ...

2003-04-01

17

Quantification of cardiac function with multislice spiral CT using retrospective EKG-gating: comparison with MRI  

International Nuclear Information System (INIS)

Purpose: To quantify left ventricular function derived from retrospectively ECG-gated multislice spiral CT (MSCT) data sets in comparison to MRI. Materials and Methods: In 16 patients (14 males, 2 females, mean age 56.8 #+-# 11.5 years), retrospectively ECG-gated MSCT angiography of the coronary arteries and breath-hold steady state free precession cine MRI were performed. From MSCT data-sets, 20 axial image series were reconstructed every 5% of the RR interval. Multiplanar images were reformatted in the short axis orientation from axial images. End-systolic and end-diastolic images were selected. From these images end-systolic volume (ESV), end-diastolic volume (EDV) and stroke volume (SV) as well as the ejection fraction (EF) and myocardial mass (MM) were determined using the Simpson's method and compared with MRI. Furthermore, image quality was assessed for both imaging modalities using a four point grading scale. Results: All parameters ...

2003-01-01

18

Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart  

Energy Technology Data Exchange (ETDEWEB)

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A{sub 1}) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs{sub eff}). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A{sub 2}). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was applied. The data of all groups were evaluated ...

2003-12-01

19

Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart  

International Nuclear Information System (INIS)

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A_1) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs_e_f_f). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A_2). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was applied. The data of all groups were evaluated by a ...

2003-12-01

20

Diagnostic value of adenosine-triphosphate radionuclide ventriculography in coronary artery disease. Comparison with conventional exercise stress method  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to assess the effect of adenosine-triphosphate (ATP) on hemodynamics and left ventricular (LV) function, and to examine the value of ATP radionuclide-ventriculography (RNVG) for detecting coronary artery disease (CAD) in comparison with standard exercise RNVG. Thirty-eight consecutive patients with suspected CAD underwent ATP (0.18 mg/Kg/min) RNVG and symptom-limited exercise RNVG. Coronary angiography revealed 27 patients with CAD (Group S) and 11 without CAD (Group N). In group S, exercise induced an increase in LV end-diastolic volume (LVEDV) and LV end-systolic volume (LVESV), and a decrease in LV ejection fraction (LVEF). In contrast, ATP infusion caused LVESV to decrease in both groups, improving LVEF. Only 14 of 39 segments whose wall motion was deteriorated by exercise showed worsening regional wall motion during ATP infusion. The sensitivity and specificity of ATP RNVG for detecting ...

1995-07-01

21

Extension of adrenal tumors into the vena cava: results of magnetic resonance angiography; Kavazapfen bei Nebennierentumoren: Kernspintomographische Befunde  

Energy Technology Data Exchange (ETDEWEB)

In rare cases, large adrenal masses with a suspicion of malignancy exhibit tumor extension into the adrenal vein and inferior vena cava. When planning surgery, the relationship of the extension to the inferior vena cava is of decisive improtance. We describe in two cases on the detection of a tumor thrombus in the inferior vena cava arising from a malignant adrenal mass by means of MR angiography (TOF, coronary 2D GRE images [FLASH], 3 slices acquired during 15 second apnea). The angiograms correlated well with the results of DSA venacavography and with the intraoperative findings. Thus, MRA has been demonstrated to be suitable for the certain proof of a venous tumor thrombus not only in cases of renal cell carcinomas but also in cases of malignant adrenal masses. The method should be applied whenever there is evidence of a venous involvement in the adrenal MR images. (orig.) [Deutsch] Grosse malignomverdaechtige Nebennierentumoren zeigen in ...

1995-11-01

22

Pharmacological Prevention of Peri-, and Post-Procedural Myocardial Injury in Percutaneous Coronary Intervention  

UK PubMed Central (United Kingdom)

In recent years, percutaneous coronary intervention (PCI) has become a well-established technique for the treatment of coronary artery disease. PCI improves symptoms in patients with coronary artery...Full Text Available

2008-08-01

23

Comparison of prasugrel and clopidogrel in patients with acute coronary syndrome undergoing percutaneous coronary intervention  

UK PubMed Central (United Kingdom)

Antiplatelet agents are the cornerstone of treatment for patients with acute coronary syndrome (ACS) undergoing percutaneous coronary intervention (PCI). Clopidogrel, when added to aspirin, has demonstrated...Full Text Available

2009-01-01

25

Evaluation of Peripheral Atherosclerosis: A Comparative Analysis of Angiography and Intravascular Ultrasound  

UK PubMed Central (United Kingdom)

ObjectiveAngiography remains a critical component for diagnostic imaging and therapeutic intervention in peripheral arterial disease (PAD). The goal of this study...Full Text Available

2010-04-01

26

Clinical evaluations of intra-arterial subtraction angiography using Fuji computed radiography  

International Nuclear Information System (INIS)

Intra-arterial subtraction angiography(IADSA) using Fuji computed radiography(FCR) was performed on 130 patients with cervical, pelvic, peripheral and abdominal diseases. It was compared with conventional angiography(radiographs produced by combining photographic film with an intensifying screen) performed on same patients. Radiographs produced by FCR were better than conventional radiographs in cervical, pelvic and peripheral angiography. In the abdominal angiography using FCR, there was misregistration artifact in some cases, but in hepatic angiography, the new radiographs under the injection of small amount of contrast medium(about 10ml) and the short exposure duration(about 10 seconds) were excellent. It was as valuable as conventional angiography (infusion hepatic angiography) for diagnosing hepatic neoplasms. (author).

1985-01-01

27

Myocardial imaging in patients with Kawasaki disease. Exercise stress imaging and serial studies  

Energy Technology Data Exchange (ETDEWEB)

Thallium-201 myocardial imaging was performed in 80 children with coronary arterial lesions due to Kawasaki disease in order to assess the value of serial and exercise myocardial imagings. In eight of these children, abnormalities of the image were noted. Twenty children had serial thallium studies with an interval of three to 18 months, and five of these showed changes in the image including appearance of a new perfusion defect in one patient and improvement of perfusion defects in four. These changes of the myocardial image were correlated well with coronary angiographic findings obtained within a few days of the isotope studies. It was noted that the changes of the myocardial image were more frequently observed at relatively recent period recovered from Kawasaki disease. Exercise myocardial imaging using a bicycle ergometer was performed in eight children with coronary arterial lesions. In three an evidence of ...

1982-06-01

28

Clinical Characteristics and Outcomes of Patients with Acute Coronary Syndrome and Prior Coronary Artery Bypass Grafting in a Large Middle Eastern Cohort  

UK PubMed Central (United Kingdom)

Background:Acute Coronary Syndrome (ACS) can occur in patients with prior coronary artery bypass grafting (CABG). In the Gulf Registry of acute coronary events (Gulf RACE), we identified...Full Text Available

31

Selective endothelin A-receptor blockade attenuates coronary microvascular dysfunction after coronary stenting in patients with type 2 diabetes  

UK PubMed Central (United Kingdom)

Background:Endothelin-1 may be involved in the development of diabetic microangiopathy. We studied the effect of endothelin-1 blockade on myocardial microcirculation during coronary...Full Text Available

2009-01-01

32

Outcome of early surgery after coronary angioplasty.  

UK PubMed Central (United Kingdom)

Nineteen of 69 patients undergoing coronary angioplasty required immediate coronary surgery after the procedure. Six of these operations were planned as a result of angioplasty that failed without producing...Full Text Available

1986-03-01

33

Chest pain and angiographically normal coronary arteries. Implications for treatment.  

UK PubMed Central (United Kingdom)

Approximately 20% to 30% of patients who undergo coronary arteriography for the evaluation of chest pain are found to have normal coronary arteries. These patients have a survival rate comparable to...Full Text Available

1993-01-01

34

Abciximab: a reappraisal of its use in coronary care  

UK PubMed Central (United Kingdom)

Platelet reactivity plays a pivotal role in the pathogenesis of ischemic adverse events during and after acute coronary syndromes (ACS), and percutaneous coronary intervention (PCI). Glycoprotein (GP)...Full Text Available

2008-03-01

35

Simultaneous assessment of left ventricular function from gated myocardial perfusion SPECT. Utility of QGS (Quantitative Gated SPECT) program  

International Nuclear Information System (INIS)

Quantitative gated SPECT (QGS) was evaluated in 7 normal volunteers and 31 patients with cardiac diseases. Adequate cut off value of a prefilter was 0.45. In phantom, the left ventricular volume value was 93.9% of determined value by 180-degree projection in L type and 98.8% by 360-degree projection in opposed type. In normal volunteers, LVEF measured by QGS program related to value by first pass method. As for functional map, regional EF and wall motion decreased at the septum side, and wall thickening at base side of heart. Good correlation was recognized (p<0.0001) between blood flow image and functional map (regional EF and wall thickening). In 20 cases of acute myocardial infarction, lesion was detected conspicuously in regional EF and wall motion. The accuracy of coronary arterial stenosis improved in functional map (regional EF 92%, wall motion 92% and wall thickening 88%). In particular, the accuracy of 3 rami lesion was 100% in ...

1998-08-01

36

Cerebral angiography using Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Eighty-seven subtraction images of FCR were compared with subtraction images of conventional angiography. Although FCR images with reduced exposure dose (25 % of regular dose) and with diluted contrast material (150 mgI/ml, 50 % of usual concentration) were slightly inferior to the images of conventional angiography, most clinically important vessels were adequately visualized. As FCR has wider dynamic range and higher contrast resolution than conventional angiography, FCR may take over conventional angiography. (author).

1985-01-01

37

T lymphocytes in aortic and coronary intimas. Their potential role in atherogenesis.  

UK PubMed Central (United Kingdom)

In order to investigate the role of mononuclear cells in infiltrates during the initial stages of atherogenesis, the authors have studied by immunohistochemical methods the aortas and coronary vessels...Full Text Available

1988-02-01

40

An In-Hospital Family Member Cardiopulmonary Resuscitation (CPR) Education Program  

Science.gov (United States)

Cardiac Arrest; Coronary Disease; Cardiovascular Risk Factors

2010-12-13

41

Angiography in dibuthylnitrosamine-induced rat bladder tumours  

International Nuclear Information System (INIS)

(1972). Denmark Ekelund, L. Goethlin, J. Henrikson, H. Letter-to-the-

42

3D rotational angiography: Benefits obtained in clinical endovascular treatments  

International Nuclear Information System (INIS)

The application of 3D rotational angiography marks a breakthrough in endovascular treatment of aneurysmas of the brain. 3D images are produced based on image series obtained by rotational angiography, so that the anatomic details of interest can be visualized from any requested angle. (orig./CB)

1999-01-01

43

Quantitative thallium-201 scintigraphy after dipyridamole infusion combined with low level exercise in healthy volunteers  

Energy Technology Data Exchange (ETDEWEB)

To establish test specific normal limits for quantitative analysis of uptake and washout of /sup 201/Tl after dipyridamole infusion combined with low level exercise, 20 healthy volunteers were studied with low likelihood of coronary artery disease (CAD) assessed by a stepwise probability analysis based on age, sex, symptoms, resting electrocardiogram, and exercise electrocardiography. Likelihood of CAD in these volunteers was calculated as less than or equal to 1%. After dipyridamole infusion combined with low level exercise, one volunteer complained of headache; no other side effects were observed. There were no chest pain complaints. Maximal hemodynamic changes were achieved during the 6th and 7th min of the test. No ST segment depression was recorded. Visual analysis of the /sup 201/Tl scintigrams was normal in all volunteers. Mean regional washout at 4 h was 44.37%+-2.11%. The regional washout in the 70/sup 0/ LAO view (46.65%+-1.10%) was ...

1989-05-01

44

Angiography of the head using Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Forty-seven subtraction images of FCR were compared with subtraction images of conventional angiography of the head. Quality of the FCR images were equal or superior to that of conventional angiography. Antero-posterior projection of external carotid arteriography by FCR was most useful because of its wide dynamic range. As contrast resolution of FCR is superior to that of conventional angiography, only half diluted contrast media was needed. As for spacial resolution, FCR is slightly inferior to conventional angiography. However, most vessels which are clinically important were adequately demonstrated. A weak point of FCR which should be improved is relatively long time to process the images after radiation exposure. (author).

1985-01-01

45

Validity of Cardiac Markers as Diagnostic and Prognostic Indicators of Complications in Patients undergoing Percutaneous Coronary Intervention  

UK PubMed Central (United Kingdom)

ObjectivesThe aim of this study was to assess the diagnostic and prognostic value of heart-type fatty acid-binding protein (H-FABP) in elective percutaneous coronary intervention...Full Text Available

2010-04-01

46

Using Multidetector Computed Tomography in a Swine Model to Assess the Effects of Sublingual Nitroglycerin and Intravenous Adenosine on Epicardial Coronary Arteries  

UK PubMed Central (United Kingdom)

This study examines the effects of intravenous infusion of adenosine and sublingual nitroglycerin on coronary angiograms obtained by current-generation multidetector computed tomography. We assessed...Full Text Available

2009-12-01

47

Use of clopidogrel in the reduction of myocardial damage during percutaneous coronary intervention  

UK PubMed Central (United Kingdom)

It is estimated that approximately a quarter of patients undergoing coronary intervention may have significant post-procedural creatinine (CK)/creatinine kinase myocardial band (CK-MB) elevations and...Full Text Available

2009-01-01

48

The Effects of Time Varying Curvature on Species Transport in Coronary Arteries  

UK PubMed Central (United Kingdom)

Alterations in mass transport patterns of low-density lipoproteins (LDL) and oxygen are known to cause atherosclerosis in larger arteries. We hypothesise that the species transport processes in coronary...Full Text Available

2006-12-01

49

The Association of Alcohol and Alcohol Metabolizing Gene Variants with Diabetes and Coronary Heart Disease Risk Factors in a White Population  

UK PubMed Central (United Kingdom)

BackgroundEpidemiological studies have shown a J- or U-shaped relation between alcohol and type 2 diabetes and coronary heart disease (CHD). The underlying mechanisms are not clear....Full Text Available

50

Spontaneous coronary artery dissection in the postpartum period: association with antiphospholipid antibody  

UK PubMed Central (United Kingdom)

Spontaneous coronary artery dissection (SCAD) is an extremely uncommon cause of myocardial infarction, occurring predominantly in women during or after pregnancy. The exact aetiology...Full Text Available

2004-09-01

51

Outpatient percutaneous coronary intervention: Ready for prime time?  

UK PubMed Central (United Kingdom)

Outpatient practice after percutaneous coronary intervention (PCI) is gaining momentum due to constantly optimizing results. Furthermore, the availability of limited beds to handle the large volume...Full Text Available

2007-10-01

52

Optimal Method of Coronary Revascularization in Patients Receiving Dialysis: Systematic Review  

UK PubMed Central (United Kingdom)

Background and objectives: Patients receiving dialysis have a high burden of cardiovascular disease. Some receive coronary artery revascularization but the optimal method is controversial.Design,...Full Text Available

2009-02-01

53

New methods of making blocked coronary arteries patent again.  

UK PubMed Central (United Kingdom)

The use of percutaneous transluminal coronary angioplasty is limited by procedural complications and the serious drawback of restenosis, but some new techniques have been developed in an attempt to...Full Text Available

1994-09-03

54

Medico-legal autopsy in postoperative hemodynamic collapse following coronary artery bypass surgery  

UK PubMed Central (United Kingdom)

Sudden unexpected postoperative hemodynamic collapse with a high mortality develops in 1–3% of patients undergoing coronary artery bypass surgery (CABG). The contribution of surgical graft complications...Full Text Available

2011-03-01

55

Left Main Coronary Stenosis as a Consequence of Bentall Operation: Percutaneous Treatment  

UK PubMed Central (United Kingdom)

A 65-year-old man suffering from ascending aorta aneurysm and atherosclerotic three vessel disease without left main involvement underwent aortic root replacement with coronary ostia reimplantation...Full Text Available

2009-01-01

56

Investigating the spatial variability in incidence of coronary heart disease in the Gazel cohort: the impact of area socioeconomic position and mediating role of risk factors  

UK PubMed Central (United Kingdom)

Study objectiveThe study aim was to improve our understanding of the relationships between contextual socioeconomic characteristics and coronary heart disease (CHD)...Full Text Available

2011-02-01

57

Gene-gene and gene-environment interactions: new insights into the prevention, detection and management of coronary artery disease  

UK PubMed Central (United Kingdom)

Despite the recent success of genome-wide association studies (GWASs) in identifying loci consistently associated with coronary artery disease (CAD), a large proportion of the genetic components of...Full Text Available

58

Explicit risk in acute coronary syndrome management  

UK PubMed Central (United Kingdom)

At least implicitly, most clinical decisions represent an integration of disease and treatment-based risk assessments. Often, as is the case with acute coronary syndrome (ACS), these decisions need...Full Text Available

2009-06-01

59

Effects of gradual coronary artery occlusion and exercise training on gene expression in swine heart  

UK PubMed Central (United Kingdom)

Gradual occlusion (O) of the swine left circumflex coronary artery (LCX) with an ameroid occluder results in complete O within 3 weeks, collateral vessel development, and compensatory hypertrophy....Full Text Available

2007-01-01

60

Drug-Eluting Stents versus Bare Metal Stents in Unprotected Left Main Coronary Artery Stenosis: a Meta-Analysis  

UK PubMed Central (United Kingdom)

ObjectivesWe undertook a meta-analysis to assess outcomes for drug-eluting (DES) and bare metal stents (BMS) in percutaneous coronary intervention (PCI) for unprotected...Full Text Available

2010-06-01

61

Coronary artery overexpansion increases neointimal hyperplasia after stent placement in a porcine model  

UK PubMed Central (United Kingdom)

ObjectiveTo determine if an aggressive approach to coronary revascularisation with oversized balloons is counterproductive, we studied the effect of increasing balloon‐to‐artery...Full Text Available

2007-12-01

62

Chronic Coronary Artery Disease: Diagnosis and Management  

UK PubMed Central (United Kingdom)

Coronary artery disease (CAD) is the single most common cause of death in the developed world, responsible for about 1 in every 5 deaths. The morbidity, mortality, and socioeconomic importance...Full Text Available

2009-12-01

63

Cholesterol and Heart Disease: Current Concepts in Pathogenesis and Treatment  

UK PubMed Central (United Kingdom)

One of the modifiable risk factors associated with coronary heart disease (CHD) is hypercholesterolemia. This paper reviews the major plasma lipids and how they relate to coronary heart disease. Among...Full Text Available

1986-08-01

64

Anger Expression and Risk of Coronary Heart Disease: Evidence From the Nova Scotia Health Survey  

UK PubMed Central (United Kingdom)

BackgroundWhile some studies have found that anger increases the risk of incident coronary heart disease (CHD), others found anger protective. Prior studies did not...Full Text Available

2010-02-01

65

A Randomized Clinical Trial Investigating the Relationship Between Aprotinin and Hypercoagulability in Off-Pump Coronary Surgery  

UK PubMed Central (United Kingdom)

BACKGROUNDOff-pump coronary artery bypass (OPCAB) surgery is associated with a hypercoagulable state in which the platelet thrombin receptor, protease-activated receptor-1...Full Text Available

2009-11-01

66

A Population-Based, Longitudinal Study of Erectile Dysfunction and Future Coronary Artery Disease  

UK PubMed Central (United Kingdom)

OBJECTIVE: To assess the association between erectile dysfunction (ED) and the long-term risk of coronary artery disease (CAD) and the role of age as a modifier of this association.PARTICIPANTS...Full Text Available

2009-02-01

67

A prospective evaluation of the safety and efficacy of the TAXUS Element paclitaxel-eluting coronary stent system for the treatment of de novo coronary artery lesions: Design and statistical methods of the PERSEUS clinical program  

UK PubMed Central (United Kingdom)

BackgroundPaclitaxel-eluting stents decrease angiographic and clinical restenosis following percutaneous coronary intervention compared to bare metal stents. TAXUS Element is a third-generation...Full Text Available

68

Successful transcatheter coil embolization of coronary artery to left ventricular fistula associated with absent pulmonary valve with tricuspid atresia in early infancy.  

Science.gov (United States)

Transcatheter coil embolization for coronary artery to left ventricular fistula was successfully performed in a neonate. At 30 weeks' gestation, fetal echocardiography showed a hypoplastic right ventricle with intact ventricular septum, absent pulmonary valve, tricuspid atresia, and marked distension of the right coronary artery. After birth, the neonate had congestive heart failure and the electrocardiogram showed myocardial ischemic changes in the left ventricular area. Aortography showed a dilated right coronary artery arising from the ascending aorta and draining into the left ventricle. Transcatheter coil embolization was carried out on the 9th day after birth. Since the procedure, no myocardial ischemic changes have been detected. Transcatheter coil embolization is a useful therapy for coronary artery fistula associated with myocardial ischemia. PMID:15564713

2004-12-01

69

The accuracy and reverse effects of thallium myocardial SPECT using adenosine triphosphate loading in the diagnosis of coronary artery disease. Comparison with other loading methods semiquantitatively  

Energy Technology Data Exchange (ETDEWEB)

The adverse effects and diagnostic accuracy of thallium-201 myocardial SPECT after intravenous infusion of adenosine triphosphate (ATP) were studied and compared with SPECT examinations with other type of loading. The subjects of the study were 147 patients with or without coronary artery disease, who underwent some type of loading SPECT and coronary arteriography (CAG) within 30 days. Myocardial ischemia was evaluated qualitatively in SPECT and was compared with CAG for the diagnostic accuracy of coronary artery disease. The degree of myocardial uptake defect was also calculated semiquantitatively using visual scoring method and compared with coronary artery severity score. The adverse effects occurred in 46.7% of ATP loading SPECT which was more frequent that DIP loading SPECT, but all of them were transient and mild. As for the diagnostic ability the ATP loading SPECT was as effective as other type ...

1999-09-01

71

Aphakic macular oedema following prosthetic lens implantation.  

UK PubMed Central (United Kingdom)

Fluorescein angiography of the iris was performed on patients with plastic lens implants with cystoid oedema of the macula, and the nature of the vascular changes was compared with controls provided...Full Text Available

1977-05-01

72

Role of nuclear medicine and magnetic resonance imaging in cardiac diagnostics; Rolle der nuklearmedizinischen Verfahren und der Magnetresonanztomographie in der kardialen Diagnostik  

Energy Technology Data Exchange (ETDEWEB)

Nuclear medicine and magnetic resonance imaging (MRI) are widely used in cardiac diagnostics. Both techniques have been carefully evaluated and are equivalent for the assessment of regional and global wall motion as well as the evaluation of ejection fraction and cardiac volumes, though MRI is herein currently seen as gold standard. For evaluation of myocardial perfusion, extensive data exist for nuclear imaging, that, next to high diagnostic accuracy for evaluation of coronary artery disease, show incremental prognostic information and allow for independent risk stratification. Because of rapid technical advance, myocardial perfusion imaging has also become feasible with cardiac MRI. Results of recent studies are promising, but the data are few compared to perfusion scintigraphy. For viability assessment in patients with ischemic cardiomyopathy, positron emission tomography (PET) with FDG is currently seen as gold standard. However, single photon emission computed ...

2003-12-01

73

Transbrachial arterial digital subtraction angiography  

International Nuclear Information System (INIS)

27 cases including 7 outpatients, underwent intraarterial DSA using 4-F nylon catheter, by transbrachial arterial approach. Much of DSAs were performed in Fuji Computed Radiography (FCR), which has high spatial resolution. In all cases, image quality satisfied clinical demands. No major complication occured in this series. Transbrachial arterial digital subtraction angiography is excellent and safe method for screening of vascular disease. (author).

1985-01-01

74

Evaluation of peripheral vascular disease by intravenous digital subtraction angiography with the Fuji computed radiography (FCR) system  

Energy Technology Data Exchange (ETDEWEB)

Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management.

1987-03-01

75

Evaluation of peripheral vascular disease by intravenous digital subtraction angiography with the Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management. (orig.).

1987-01-01

76

Angiography in the diagnosis and treatment of trauma  

Energy Technology Data Exchange (ETDEWEB)

Angiography plays a vital role in the investigation of the patient suffering from multiple trauma. The commonest injuries have been rupture of the thoracic aorta, renal lacerations, arterial bleeding associated with fractures and soft-tissue injuries to the pelvis, and occlusions of the arteries supplying the limbs. Transcatheter arterial embolization may be the definitive therapeutic procedure in pelvic bleeding.

1983-09-01

78

The SPIRIT V Study:A Clinical Evaluation of the XIENCE V Everolimus-Eluting Coronary Stent System in the Treatment of Patients With De Novo Coronary Artery Lesions  

British Library Electronic Table of Contents (United Kingdom)

ObjectivesThe SPIRIT V (A Clinical Evaluation of the XIENCE V Everolimus-Eluting Coronary Stent System in the Treatment of Patients With De Novo Coronary Artery Lesions) study is a post-market surveillance experience of the XIENCE V (Abbott Vascular, Santa Clara, California) everolimus-eluting stent (EES) in patients with higher-risk coronary anatomy. BackgroundPrevious pre-approval studies have shown the safety and efficacy of EES in highly selected groups of patients. MethodsThe SPIRIT V trial is a prospective, open label, single arm, multicenter study. Two thousand seven hundred patients with multiple de novo coronary artery lesions suitable for treatment with a planned maximum of 4 EES were enrolled at 93 centers in Europe, Asia Pacific, Canada, and South Africa. Lesions had a referenc...

2011-01-01

79

Hypersersensitivity and Kounis syndrome due to a viper bite  

British Library Electronic Table of Contents (United Kingdom)

A 60-year-old male was bitten by a venomous snake (Vipera ammodytes) and gradually developed signs of an allergic reaction including generalized itching, generalized rash, and chest discomfort. This was followed by severe retrosternal pain with electrocardiographic evidence of an inferior myocardial ischemia progressing to acute myocardial infarction. Cardiac enzymes and troponin, serum tryptase, and histamine were elevated. Coronary arteriography showed normal coronary arteries. This is a characteristic type I variant of Kounis syndrome, which is the concurrence of acute coronary syndromes with conditions associated with mast cell activation including allergic or hypersensitivity reactions as well as anaphylactic or anaphylactoid reactions. This is the first report to show that viper bite...

2006-01-01

80

Evaluation of the compressive mechanical properties of endoluminal metal stents.  

Science.gov (United States)

The mechanical properties of metal stents are important parameters in the consideration of stent design, matched to resist arterial recoil and vascular spasm. The purpose of this study was to develop a system for a standardized quantitative evaluation of the mechanical characteristics of various coronary stents. Several types of stents were compressed by external hydrostatic pressure. The stent diameter was assessed by placing a pair of small ultrasonic sono-crystals on the stent. From pressure-strain diagrams the ultimate strength and radial stiffness for each stent were determined. For all stents, except the MICRO-II and the Wiktor stent, the diameter decreased homogeneously until an ultimate compressive strength was exceeded, causing an abrupt collapse. Expanded to 3 mm, the mechanical behavior of the beStent, the Crown and the Palmaz-Schatz stent (PS153-series) were comparable. The spiral articulated Palmaz-Schatz stent showed twice the ...

1998-06-01

81

Arterial and Venous Thrombosis in Cancer Patients  

UK PubMed Central (United Kingdom)

The most frequent ultimate cause of death is myocardial arrest. In many cases this is due to myocardial hypoxia, generally arising from failure of the coronary macro- and microcirculation to deliver...Full Text Available

82

Three-dimensional rotational angiography of the carotid arteries with high-flow injection from the aortic arch. Preliminary experience  

International Nuclear Information System (INIS)

Purpose: Three-dimensional rotational angiography (3DRA) is a new technique based on a rotational angiographic acquisition able to display arterial vessels in a 3D rendering mode. The system was mainly developed for neuroradiological evaluations but preliminary extracranial experiences have also been reported. The aim of our work was to compare the results of three-dimensional angiography of the carotid arteries done with high-flow injection of contrast medium from the aortic arch with the results of selective angiography. Materials and methods: Twenty patients underwent digital angiography of the supra-aortic vessels in order to quantify a stenosis of the carotid bifurcations previously detected at Doppler Ultrasound. Examinations were performed with the Philips Integris Allura system provided with the rotational angiography (RA) tool connected to a workstation for ...

83

Blood flow quantification with MRI using the phase mapping method. Moeglichkeiten und Grenzen der Blutflussquantifizierung peripherer arterieller Gefaesse mit der MRT unter Anwendung des Phase-Mapping-Verfahrens  

Energy Technology Data Exchange (ETDEWEB)

MRT is able to demonstrate arteries while MR angiography can quantify blood flow by a non-invasive method. In the present paper blood flow measurements were carried out in four selected cases on the basis of phase mapping. In 3 patients with lesions in the pelvis or thigh, angiography was performed in order to localise the stenosis or occlusion and this was followed by qantitative blood flow measurements. The results showed that angiography may not always provide all necessary information concerning a haemodynamically significant stenosis. The method may also be used for quantifying blood flow in the renal arteries and that it has significant advantages over the colour Doppler method. (orig.).

1992-08-01

84

Use of platelet glycoprotein IIb/IIIa inhibitors in diabetics undergoing PCI for non-ST-segment elevation acute coronary syndromes: impact of clinical status and procedural characteristics  

UK PubMed Central (United Kingdom)

BackgroundThe most recent ESC guidelines for percutaneous coronary intervention (PCI) recommend the use of glycoprotein IIb/IIIa inhibitors (GPI) in high risk patients with non-ST-segment...Full Text Available

2010-06-01

85

Adenosine triphosphate loading thallium-201 myocardial scintigraphy. Optimal dose and diagnostic accuracy  

Energy Technology Data Exchange (ETDEWEB)

Adenosine triphosphate (ATP) is an alternative to dipyridamole or adenosine in thallium-201 myocardial scintigraphy. However, the optimal dose of ATP has not been determined. A Doppler guide wire study showed the coronary flow velocity at a dose of 0.15 mg/kg of ATP was equal or higher than that at 0.14 mg/kg of adenosine or 0.56 mg/kg of dipyridamole. ATP was given intravenously to 67 patients with coronary artery disease at 0.15 mg/kg/min for 6 min. Thallium-201 was injected at 3 min, followed by immediate and delayed (3 hrs) tomographic imaging. There was no serious side effect during examination, although chest pain (26%), dyspnea (17%), and flushing (33%) were common. The sensitivity and specificity to detect coronary artery disease were 98 and 100%, respectively. The sensitivity to detect left anterior descending artery, left circumflex artery, and right coronary artery lesions was 94, 59 and 77%, ...

1995-01-01

86

Is Computerized Tomography Angiographic Surveillance Valuable for Prevention of Tracheoinnominate Artery Fistula, a Life-Threatening Complication after Tracheostomy?  

UK PubMed Central (United Kingdom)

ObjectiveThe aim of this study was to evaluate the utility of volume-rendered helical computerized tomography (CT) angiography focusing tracheostomy tube and innominate artery for...Full Text Available

2011-02-01

87

Clinical efficacy of the use of information technology in cardiology: initial results of angiographic teleconsultation in the Netherlands  

UK PubMed Central (United Kingdom)

Background With the increasing use of cineless diagnostic angiography laboratories, modern telecommunication networks provide an excellent opportunity to transfer dynamic cardiac...Full Text Available

2001-12-01

88

Quantitation of Antibiotics by High-Pressure Liquid Chromatography: Cephalothin  

UK PubMed Central (United Kingdom)

A technique for quantitative determination of cephalothin and desacetylcephalothin in serum using a method based on high-pressure liquid chromatography is described. Both compounds were quantitatively...Full Text Available

1978-02-01

89

Detection of intracardiac calcification using Fuji computed radiography  

International Nuclear Information System (INIS)

Fuji Computed Radiography (FCR) was evaluated for detection of intracardiac calcification as compared with conventional radiography in 77 patients. Intracardiac calcification was found in 37 patients (left coronary artery: 31, right coronary artery: 11, valve: 9) on cine-fluorography. The sensitivity for detecting these calcified foci with FCR was higher than conventional screen-film method. Especially, sensitivity for detecting left coronary artery calcification with FCR was significantly higher than conventional method (71 %, 32 %) (p < 0.01), Fine anatomical details of calcification were well shown on FCR. Chest radiography using FCR is of great use for detection of intracardiac calcification. (author).

1986-01-01

90

Trial of early nifedipine in acute myocardial infarction: the Trent study.  

UK PubMed Central (United Kingdom)

Over 30 months 9292 consecutive patients admitted to nine coronary care units with suspected myocardial infarction were considered for admission to a randomised double blind study comparing the effect...Full Text Available

1986-11-08

91

Transmural distribution of extracellular purines in isolated guinea pig heart.  

UK PubMed Central (United Kingdom)

The purine adenosine appears to be involved in regulation of coronary vascular tone. Little is known concerning the levels and distribution of adenosine and related purines in the extracellular fluid...Full Text Available

1991-01-15

92

TECAB - Totally Endoscopic Coronary Artery Bypass  

Medline Plus

... CT angiograph for the peripheral rteries. a beautiful 3D-vision on the structures inside e chest. Okay. ... have an angled camera here. This is a 3D camera, and the surgeon has got th What ...

93

Stent expansion: a combination of delivery balloon underexpansion and acute stent recoil reduces predicted stent diameter irrespective of reference vessel size  

UK PubMed Central (United Kingdom)

BackgroundThere is a strong inverse relationship between final vessel diameter and subsequent risk of treatment failure after coronary stent deployment. The aim of this study was...Full Text Available

2007-12-01

94

Normal Coronary Artery Patient Presenting with Left Ventricular Aneurysm  

UK PubMed Central (United Kingdom)

Left ventricular aneurysm (LVA) is one of the most important complications of myocardial infarction LVA is strictly defined as a distinct area of abnormal left ventricular diastolic contour with systolic...Full Text Available

2011-01-01

95

Neointimal hyperplasia persists at six months after sirolimus-eluting stent implantation in diabetic porcine  

UK PubMed Central (United Kingdom)

BackgroundObservational clinical studies have shown that patients with diabetes have less favorable results after percutaneous coronary intervention compared with the non-diabetic...Full Text Available

97

Left Main Stent Thrombosis Complicated by Eptifibatide-Induced Acute Thrombocytopenia  

UK PubMed Central (United Kingdom)

A 57-year-old man with a history of coronary artery disease and placement of an implantable cardioverter-defibrillator presented at our emergency room with an anterior ST-elevation myocardial infarction....Full Text Available

2011-01-01

98

Intravascular ultrasound to guide the management of intracoronary thrombus: a Case Report  

UK PubMed Central (United Kingdom)

Percutaneous coronary intervention can be associated with distal embolization of thrombotic material causing myocardial necrosis and infarction.We discuss the role of intravascular imaging to...Full Text Available

99

In-vivo coronary flow profiling based on biplane angiograms: influence of geometric simplifications on the three-dimensional reconstruction and wall shear stress calculation  

UK PubMed Central (United Kingdom)

BackgroundClinical studies suggest that local wall shear stress (WSS) patterns modulate the site and the progression of atherosclerotic lesions. Computational fluid dynamics (CFD)...Full Text Available

100

Impact of sphingomyelin levels on coronary heart disease and left ventricular systolic function in humans  

UK PubMed Central (United Kingdom)

Sphingomyelin (SM) is an abundant phospholipid in cell membranes and in lipoproteins. In human plasma, SM is mainly found in atherogenic lipoproteins; therefore, higher levels of SM may promote atherogenesis....Full Text Available

101

Health-related quality of life following percutaneous coronary intervention: the impact of age on outcome at 1 year.  

Science.gov (United States)

This study was performed to assess the possibility that patient age may independently affect improvements in health-related quality of life following percutaneous coronary intervention. One hundred five patients undergoing elective percutaneous coronary intervention at a single tertiary referral center between January 10, 2001 and January 6, 2002 were enrolled and prospectively evaluated. Health-related quality of life was assessed before and 1 year following percutaneous coronary intervention using Short Form-12 and the Seattle Angina Questionnaire. For the purpose of analysis, patients were divided according to age (younger than 60, 60-70, and older than 70 years). One hundred patients (95%) completed both questionnaires. Baseline characteristics among the age groups were similar in terms of gender, cardiac risk factors, and procedural details. All health-related quality-of-life indices demonstrated improvements with at ...

102

Considerable Variability in Platelet Activity among Patients with Coronary Artery Disease in Response to an Increased Maintenance Dose of Clopidogrel  

UK PubMed Central (United Kingdom)

BackgroundVariable platelet response to clopidogrel has been widely observed. Studies have shown that the mean aggregation response to clopidogrel can be changed...Full Text Available

2009-05-01

103

Complement Localization and Mediation of Ischemic Injury in Baboon Myocardium  

UK PubMed Central (United Kingdom)

We sought to determine whether the third component of complement (C3) is localized in ischemic baboon myocardium after coronary artery ligation. Furthermore, we assessed the effects of prior C3 depletion...Full Text Available

1980-11-01

104

Cangrelor increases the magnitude of platelet inhibition and reduces interindividual variability in clopidogrel-pretreated subjects  

UK PubMed Central (United Kingdom)

BackgroundInadequate platelet inhibition despite aspirin and clopidogrel therapy during and after a percutaneous coronary intervention is associated with an impaired clinical outcome....Full Text Available

2009-05-01

105

Body mass index, waist circumference, and risk of coronary heart disease: a prospective study among men and women  

UK PubMed Central (United Kingdom)

ObjectiveThe purpose of the study was to assess the risk of CHD associated with excess weight measured by BMI and waist circumference (WC) in two large cohorts of...Full Text Available

2010-01-01

106

Association between erectile dysfunction and cardiovascular risk in individuals with type-2 diabetes without overt cardiovascular disease  

UK PubMed Central (United Kingdom)

Background:Erectile dysfunction in type-2 diabetes may be an independent marker for coronary artery disease. Present study was undertaken to investigate whether type-2 diabetic...Full Text Available

2009-10-01

107

Aspirin and Clopidogrel Response Variability  

UK PubMed Central (United Kingdom)

Antiplatelet resistance has been proposed as a possible mechanism to explain recurrent cardiovascular events in patients who have coronary artery disease and who are undergoing dual antiplatelet therapy....Full Text Available

2008-01-01

108

Artery phantoms for intravascular optical coherence tomography: healthy arteries  

UK PubMed Central (United Kingdom)

We present a method to make phantoms of coronary arteries for intravascular optical coherence tomography (IV-OCT). The phantoms provide a calibrated OCT response similar to the layered structure of...Full Text Available

109

Akt pathway is hypoactivated by synergistic actions of diabetes mellitus and hypercholesterolemia resulting in advanced coronary artery disease  

UK PubMed Central (United Kingdom)

Atherosclerosis is an inflammatory process leading to enhanced cellular proliferation, apoptosis, and vasa vasorum (VV) neovascularization. While both diabetes mellitus (DM) and hypercholesterolemia...Full Text Available

2010-09-01

110

A new method to measure necrotic core and calcium content in coronary plaques using intravascular ultrasound radiofrequency-based analysis  

UK PubMed Central (United Kingdom)

Although previous intravascular ultrasound (IVUS) radiofrequency-based analysis data showed acceptable reproducibility for plaque composition, measurements are not easily obtained, particularly that...Full Text Available

2010-04-01

111

PET/CT cardiology: an area whose boundaries are still out of sight  

International Nuclear Information System (INIS)

Positron emission tomography (PET) and X-ray computed tomography (CT) performed with PET/CT cameras allow us to obtain concurrently information on the presence and degree of alterations of myocardial perfusion and metabolism and on coronary arteries calcification. Furthermore, by gated myocardial perfusion studies, PET may provide crucial information on regional coronary blood flow reserve and endothelial dysfunction. A number of recent papers provide some insight on the potential of PET/CT in cardiology and in the assessment of various cardiovascular diseases including various types of vasculitis and metabolic diseases.

2006-05-01

112

Non-selective cervical and cerebral three-dimensional rotational angiography  

International Nuclear Information System (INIS)

To evaluate the usefulness of three-dimensional (3D) rotational angiography, cervical carotid or cerebral angiography was done without catheterizing the branches of the thoracic aorta. A 5-Fr pig-tail type catheter was passed into the ascending aorta via the radial artery or the femoral artery. Optimal carotid angiogram views were obtained using approximately 45 ml of contrast medium at a flow rate of 15 ml/sec. Optimal cerebral angiogram views were obtained using approximately 70 ml of contrast medium at a flow rate of 20 ml/sec. The contrast medium concentration was 300 to 350 mgI/ml. A satisfactory view could be obtained in 5 of 8 (63%) cases on cervical carotid 3D angiography and in 8 of 14 (57%) cases on cerebral 3D angiography. In all cases, no complications were noted. This method offers the advantages of requiring a relatively short procedure time and a decrease in radiation exposure. Further ...

2007-09-01

113

Digital subtraction angiography with scanning lazer stimulated luminescence  

International Nuclear Information System (INIS)

Fuji Computed Radiography (FCR) utilizes imaging plates of scanning lazer stimulated luminescence. FCR can be used for intravenous digital subtraction angiography (IVDSA) and for intraarterial studies because of tis high contrast and spatial resolution. Pixel size of the imaging plates for angiography is 0.2 mm. Experimentally, it could demonstrate a vessel 1 mm in diameter with a contrast of 0.1, when opacified with a contrast medium of 3 % iodine concentration, and could image a vessel 3 mm in diameter with contrast of 0.1, when opacified with 1 % contrast medium. A 20 % stenosed portion of a vessel 3 mm in diameter was identified when opacified with 3 % contrast medium, and a 20 % stenosed portion of a vessel 2 mm in diameter was identified when opacified with 10 % contrast medium. In 105 IVDSA examinations of 75 patients, FCR was superior to Digital Fluorography (DF) in spatial resolution, size of examination field, dynamic range and ...

1985-01-01

114

Study of spatial resolution in three-dimensional rotational angiography  

International Nuclear Information System (INIS)

In interventional radiology (IVR) of cerebral aneurysms, it is important to understand the form and physical relationships between the cerebral aneurysm and the surrounding vessels. However, because the vessels in the head area are highly complex, it can be difficult to comprehend the structure using conventional angiography. Therefore, three-dimensional rotational angiography (3D-RA) has been used in recent years. This article discusses studies of the spatial resolution of 3D-RA. We reconstructed 3D-RA of an acrylic slit phantom (slit widths: 0.5, 0.75, 1.0, 1.5 mm) and examined spatial resolution by visual evaluation and profile curves. When the slit phantom was arranged to avoid the effect of beam hardening, the spatial resolution of 3D-RA was found to be as high as 0.75 mm. When the slit phantom was placed orthogonal to the rotational axis of the C-arm, the spatial resolution of 3D-RA was decreased because of the cone angle effect of ...

2006-03-01

115

Large intracranial vessel occlusion arising after radiotherapy for craniopharingioma. A case report and review of the literature  

Energy Technology Data Exchange (ETDEWEB)

We report a patient who developed occlusion of the intracranial major arteries induced by radiation therapy for craniopharyngioma. The patient, a 9-year-old boy, presented with deterioration of vision, nausea and vomiting. He underwent a right ventriculo-peritoneal shunt operation, and the tumor was partially removed. Postoperatively, he received focal radiation therapy with total of 60 Gy. Preoperative cerebral angiography, cerebral vessels had no sigh of occlusive lesion or stenosis. One year after irradiation, he started to have repeated cerebral ischemic attacks. But no regrowth of the tumor was detected on CT scans. Two years and 8 months after irradiation, he suddenly had right hemiparesis. Cerebral angiography revealed severe stenosis of the right anterior cerebral artery (precommunicating segment), middle cerebral artery (horizontal portion) and terminal portion of the right carotid artery. Left carotid angiography ...

1994-10-01

116

Large intracranial vessel occlusion arising after radiotherapy for craniopharingioma. A case report and review of the literature  

International Nuclear Information System (INIS)

We report a patient who developed occlusion of the intracranial major arteries induced by radiation therapy for craniopharyngioma. The patient, a 9-year-old boy, presented with deterioration of vision, nausea and vomiting. He underwent a right ventriculo-peritoneal shunt operation, and the tumor was partially removed. Postoperatively, he received focal radiation therapy with total of 60 Gy. Preoperative cerebral angiography, cerebral vessels had no sigh of occlusive lesion or stenosis. One year after irradiation, he started to have repeated cerebral ischemic attacks. But no regrowth of the tumor was detected on CT scans. Two years and 8 months after irradiation, he suddenly had right hemiparesis. Cerebral angiography revealed severe stenosis of the right anterior cerebral artery (precommunicating segment), middle cerebral artery (horizontal portion) and terminal portion of the right carotid artery. Left carotid angiography ...

1994-01-01

117

Assessment of flow quantification in coronary bypass grafts and coronary arteries with velocity-encoded cine MR imaging; Flussquantifizierung in Koronar- und Bypassgefaessen mit der MR-Phasenkontrasttechnik  

Energy Technology Data Exchange (ETDEWEB)

Materials and methods: 12 patients with 22 coronary bypass grafts underwent intraoperative flow quantification using the transit time ultrasound method. These values were compared to postoperative MR phase shift measurements. Flow measurements were performed preoperatively in 28 coronary arteries of 20 patients. For flow measurement, we used a velocity-encoded k-space segmented gradient echo sequence with a temporal resolution of 110 or 125 ms, respectively. 6-8 pase shift images could be acquired during one cardiac cycle. Results: There was a significant correlation between intraoperative and flow measurements using velocity-encoded MR imaging (r=0.76, p<0.0001, t-test). Flow volumes determined by MR imaging were systematically larger than those determined by the transit time ultrasound method. Mean flow in coronary arteries was reduced in severely stenosed vessels (>70%) compared to normal vessels. Intra- ...

2000-02-01

118

Somatic and genetic radiation exposure of the patient in digital subtraction angiography (DSA)  

International Nuclear Information System (INIS)

The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation doses absorbed within the critical organs - red bone marrow, lung, thyroid gland and female breast - and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. projection, the use of an abdominal compression device and careful caudal shielding of the field are advocated. (orig.).

1986-01-01

119

SPIO-enhanced MR angiography for the detection of venous thrombosis in an animal model; SPIO-unterstuetzte MR-Angiographie zur Detektion venoeser Thromben im Tiermodell  

Energy Technology Data Exchange (ETDEWEB)

Purpose: An animal model is used to investigate whether MR angiography combined with super-paramagnetic particles of iron oxide (SPIO) is suitable for detecting thromboses. Methods: 42 rats in groups of 7 each were examined on days 1, 3, 5, 7, 9 and 11, respectively, after mechanical/chemical thrombus induction in a 1.5 Tesla magnet with a FISP sequence (TR/TE/FA 50 ms/6 ms/40 ). Imaging was performed before and up to 90 minutes after intravenous injection of 30 {mu}mol FE/kg BW of the experimental SPIO (hydrodynamic diameter, 34{+-}17 nm LLS; R1 and R2 relaxivity at 0.47 T, 31 and 57 L/(mmol*s)). MIP reconstructions of MR angiographies were submitted to consensus assessment by two examiners using histology as the gold standard. Results: The image quality of MIP reconstructions was rated as good in 38 of 42 cases. With regard to thrombotic vessel occlusion, MR angiography coincided with histology in 17 of 42 cases and ...

1999-03-01

120

Reduction of diagnostic expense in space-occupying processes of the pancreas by fine-needle biopsy under computerized tomography (CT)  

International Nuclear Information System (INIS)

Comparative analysis of diagnostic accuracy (dignity determination) in CT-guided fine-needle biopsy (141 patients), CT (141), ultrasonography (89), angiography (50), and cholegraphy (ERCP, 55), was carried out in suspected space-occupying lesions of the pancreas. With accuracy of 86%, sensitivity of 37% and specificity of 92% fine-needle biopsy was superior to imaging procedures. Additional comparison of the results concerning the patients and Roc curves confirm the statements. For reduction of the number of imaging investigations a diagnostic algorithm is proposed, that starts with diagnostic CT and subsequent fine-needle biopsy controlled by CT. This would result in a more adequate use of angiography and ERCP and in the elimination of ultrasonography. (author).

121

Thoracic aortic stent graft: comparison of contrast-enhanced MR angiography and CT angiography in the follow-up: initial results  

Energy Technology Data Exchange (ETDEWEB)

The objective of this study was to compare contrast-enhanced magnetic resonance angiography (CE MRA) and multislice computed tomographic angiography (MS CTA) in the follow-up of thoracic stent-graft placement. The CE MRA and MS CTA were performed following nitinol stent-graft treatment due to thoracic aneurysm (n=4), intramural bleeding (n=2) and type-B aortic dissection (n=5). Corresponding evaluation of arterial-phase imaging characteristics focused on the stent-graft morphology and leakage assessment. Stent-graft and aneurysm extensions were comparable between both techniques. Complete exclusion (aneurysm, n=4; dissection, n=2) was assessed with high confidence with CE MRA and MS CTA. Incomplete exclusion (intramural bleeding, n=2; dissection, n=3) was assigned to lower confidence scores on CE MRA compared with MS CTA. On CE MRA the stent-graft lumen demonstrated an inhomogeneous signal, the stent struts could not be assessed. The CE MRA can ...

2003-07-01

122

Medical explorations by radioisotopes in Lebanon  

International Nuclear Information System (INIS)

This study mainly concerns medical explorations by radioisotopes. Detectors with medical exams and applications are described. Ionisation chambers, semiconductor detectors and scintillation counters are also presented. Uses of radioisotopes in medicine in vivo and in vitro techniques are explained. Examples of scintiscanning are given like: angiography, nuclear cardiography and thyroid scintiscanning. The importance of the study is to present a panorama of nuclear medicine laboratories -at the time- in hospitals in Lebanon.

123

Hepatocellular carcinoma: recent advances in diagnosis with iodized oil  

Energy Technology Data Exchange (ETDEWEB)

This opinion presents an overview of recent developments in the diagnosis and treatment of hepatocellular carcinoma (HCC) in Japan. The use of Ethiodol (iodized ethyl ester of the fatty acid of poppyseed oil) for hepatic angiography in diagnosing and treating (combined with chemotherapeutic agents) HCC has been reported. Ethiodol has been found to localize in HCC and remain there for long periods. The implications of these findings are discussed.

1985-01-01

124

Validation of biological markers for quantitative risk assessment.  

UK PubMed Central (United Kingdom)

The evaluation of biological markers is recognized as necessary to the future of toxicology, epidemiology, and quantitative risk assessment. For biological markers to become widely accepted, their validity...Full Text Available

1991-01-01

125

From Quantitative Microscopy to Automated Image Understanding  

UK PubMed Central (United Kingdom)

Quantitative microscopy has been extensively used in biomedical research and has provided significant insights into structure and dynamics at the cell and tissue level. The entire procedure...Full Text Available

2004-01-01

126

Regional myocardial perfusion in patients with atherosclerotic coronary artery disease, at rest and during angina pectoris induced by tachycardia  

International Nuclear Information System (INIS)

We studied regional myocardial perfusion by scintigraphic computer-assisted analysis of initial distribution, washout rates, and residual activity of "1"3"3Xe injected into the left coronary artery of four patients with normal arteriograms and 14 patients with coronary stenosis. At rest, residual activity in poststenotic regions was always greater than in control regions, but initial washout rates were not slower. During angina, following xenon injections, the amount of indicator distributed to the poststenotic regions was markedly reduced; the increase of the initial washout rates was smaller than in control regions relative to rest, and residual activity was higher. Initial washout rates did not differ as much as from those of normal myocardium because in severe ischemia too little indicator is deposited initially in these regions to produce a change of any magnitude. Indeed, when angina was induced immediately after the xenon injection, ...

127

MRI in preoperative evaluation of chronic paranasal sinusitis - a comparison with CT  

International Nuclear Information System (INIS)

Purpose: To determine the value of MRI in the preoperative evaluation of chronic paranasal sinusitis and to compare the results with CT and intraoperative findings. Method/Materials: 42 patients with clinical signs of chronic paranasal sinusitis underwent MRI after CT evaluation on one day, with subsequent functional endoscopic sinus surgery on the next day. Coronary CT was obtained with 5-mm slices and table-feed in the prone position, while MRI was performed in the supine position with coronary T_2-TSE+pd and coronary and transverse HASTE, each with 5-mm slice thickness. Aquisition time in MRI was less than 8 minutes. Two radiologists reviewed the CT and MRI scans for signs of sinusitis and detection of anatomical landmarks. The results were correlated with the intraoperative findings. Results: MRI offered no artifacts of dental work and showed more often high quality pictures than CT. CT and MRI demonstrated a good ...

2001-04-01

128

Health Related Quality of Life After Percutaneous Coronary Revascularisation in Patients with Previous Coronary Artery Bypass Grafts: A Two-Year Follow Up Study  

British Library Electronic Table of Contents (United Kingdom)

Percutaneous coronary revascularisation [PCR] improves angina and health related quality of life [HRQOL] compared to standard medical therapy. It is unknown whether PCR has the same benefits for patients with a history of CABG. Over a period of 5?years, we assessed HRQOL of patients undergoing PCR using Part 1 of the Nottingham Health Profile [NHP] at baseline 3, 12 and 24?months. We compared HRQOL after PCR in 255 patients with CABG to 2680 without. There were more males [81.1% v 69.6% p?=?0.002] and older patients [mean age 60.1?years v. 58.0 p?=?0.03] in CABG group. Perceived HRQOL improved at 24?months for pain, energy and emotional reaction but the improvement was less in the CABG group. However, mean NHP scores at 24?months for those with CABG had returned to baseline levels for slee...

2011-01-01

129

Transcutaneous oximetry compared to ankle-brachial-index measurement in the evaluation of percutaneous transluminal angioplasty  

International Nuclear Information System (INIS)

Objective: To investigate transcutaneous oximetry as parameter of the microcirculation is correlated to ankle-brachial-index as parameter of the macrocirculation after peripheral angioplasty procedures. Design: Prospective study. Materials and methods: 60 patients suffering from intermittent claudication were scheduled for angioplasty treatment. 45 patients were considered as eligible for angioplasty after angiographic evaluation, 15 patients underwent angiography only. Transcutaneous oximetry measurements were performed before the procedure, at the end of intervention, 24 h as well as 2 and 4 weeks after percutaneous transluminal angioplasty. Ankle-brachial-indices were obtained before intervention, 24 h as well as 2 and 4 weeks later. Results: Ankle-brachial-indices increased significantly at 24 h after angioplasty in patients being treated with angioplasty. Transcutaneous oximetry values dropped significantly at the end of the procedure and returned close to the ...

2007-11-01

130

Fish intake and acute coronary syndrome  

British Library Electronic Table of Contents (United Kingdom)

Aims To study the effect of fish consumption on the risk of acute coronary syndrome (ACS) in healthy subjects. Methods and results This Danish follow-up study included 57 053 men and women between 50 and 64 years. Intake of lean and fatty fish was estimated from a detailed and validated food frequency questionnaire. Potential cases of ACS were identified through nationwide medical databases. A total of 1122 cases of ACS were verified during a mean follow-up period of 7.6 years. Among men, intake of fatty fish was associated with a lower risk of ACS. For men in the highest quintile of fish intake compared with the lowest quintile, the hazard ratio was 0.67 (95% confidence interval: 0.53-0.85). The inverse association was observed for intakes >6 g of fatty fish per day with no obvious additi...

2010-01-01

131

Depression, coronary artery disease, type 2 diabetes, metabolic syndrome and quality of life in Taiwanese adults from a cardiovascular department of a major hospital in Southern Taiwan  

British Library Electronic Table of Contents (United Kingdom)

Aims.- To examine the relationships between depression, coronary artery disease, type 2 diabetes, metabolic syndrome and quality of life in Taiwanese adults from a cardiovascular department of a major hospital in Taiwan. Background.- Research suggests associations between depression, metabolic syndrome and quality of life. Despite this fact, few studies have investigated these relationships among Taiwanese. Design.- A cross-sectional descriptive correlational design was used to conduct this study. Methods.- A convenience sample of 140 adults participated in the study. Data were analysed with descriptive statistics, Pearson-s correlations, hierarchical regression and t-tests. Results.- Almost a half of the subjects (465%) had metabolic syndrome. The most common combination of metabolic synd...

2011-01-01

132

Comparison of Effectiveness and Safety of Ranolazine Versus Amiodarone for Preventing Atrial Fibrillation After Coronary Artery Bypass Grafting  

British Library Electronic Table of Contents (United Kingdom)

Atrial fibrillation (AF) is common after coronary artery bypass grafting (CABG) and increases the morbidity and cost. Amiodarone reduces AF after CABG. Ranolazine, an antianginal agent, also prolongs atrial refractoriness and inhibits after depolarizations and triggered activity; effects that could decrease AF after CABG. The present study compared amiodarone versus ranolazine for the prevention of AF after CABG. A retrospective cohort study of patients undergoing CABG at Aspirus Hospital from June 2008 to April 2010. The patients received either amiodarone (400 mg preoperatively followed by 200 mg twice daily for 10 to 14 days) or ranolazine (1,500 mg preoperatively followed by 1,000 mg twice daily for 10 to 14 days). The primary end point was any identified AF after CABG. A total of 393 ...

2011-01-01

139
140

X-ray findings in patients with miliary appearance of metallic mercury after suicide attempt  

Energy Technology Data Exchange (ETDEWEB)

This case report evaluates X-ray findings in patients with miliary accumulation of mercury observed after parenteral application of metallic mercury in a suizide attempt. There are certain discrepancies between clinical symptoms and the X-ray findings. A clear demonstration of mercury in coronary blood vessels is possible by fluoroscopy.

1985-03-01

141

The Significance of Clopidogrel Low-Responsiveness on Stent Thrombosis and Cardiac Death Assessed by the Verifynow P2Y12 Assay in Patients With Acute Coronary Syndrome Within 6 Months After Drug-Eluting Stent Implantation  

UK PubMed Central (United Kingdom)

Background and ObjectivesClopidogrel resistance or low-responsiveness may be associated with recurrent atherothrombotic events after drug-eluting stent (DES) implantation. We prospectively...Full Text Available

2009-12-01

142

Telemetry system for monitoring the ECG for patients with high cardiovascular risk. Main design requirements and technical solutions  

International Nuclear Information System (INIS)

In this paper the main design requirements concerning the setting up of a telemetry ECG monitoring system are presented. The design's most important technical solutions as well as some details are also discussed. This system is intended to provide skilled medical assistance during the cardiac rehabilitation of both asymptomatic and high risk coronary patients

2005-01-01

143

Radiation doses and somatic risk to patients during cardiac radiological procedures  

International Nuclear Information System (INIS)

The radiation dose to a series of adult and paediatric patients undergoing cardiac catheterisations and adults having percutaneous transluminal coronary angioplasty has been measured/determined directly using lithium fluoride thermoluminescent dosemeters and indirectly using an air ionisation chamber which indicated exposure-area product. Somatic and genetic risks are estimated from the dosimetry results. It is suggested that the magnitude of the radiation hazard is negligible compared with other clinical hazards associated with these procedures. (author).

1986-01-01

144

Physical activity at work and job responsibility as risk factors for fatal coronary heart disease and other causes of death.  

UK PubMed Central (United Kingdom)

Altogether 99 029 men aged 40-59, employed on the Italian railroad system, were classified in three levels of physical activity at work and three levels of job responsibility and then followed up for...Full Text Available

1985-12-01

145

Myeloid-Related Protein-8/14 and the Risk of Cardiovascular Death or Myocardial Infarction after an Acute Coronary Syndrome in the PROVE IT-TIMI 22 Trial  

UK PubMed Central (United Kingdom)

BackgroundUsing a transcriptional profiling approach, we recently identified myeloid-related protein-8/14 (MRP-8/14) to be expressed by platelets during acute MI....Full Text Available

2008-01-01

146

Blood EPA and DHA Independently Predict All-Cause Mortality in Patients with Stable Coronary Heart Disease. The Heart and Soul Study  

UK PubMed Central (United Kingdom)

BackgroundOmega-3 fatty acid (n-3 FA) blood levels and intakes have been inversely associated with risk for sudden cardiac death, but their relationship with all-cause...Full Text Available

2010-07-01

147

Associations of major bleeding and myocardial infarction with the incidence and timing of mortality in patients presenting with non-ST-elevation acute coronary syndromes: a risk model from the ACUITY trial  

UK PubMed Central (United Kingdom)

AimsTo evaluate the associations of myocardial infarction (MI) and major bleeding with 1-year mortality. Both MI and major bleeding predict 1-year mortality in patients presenting...Full Text Available

2009-06-01

148

Assessment of Glucagon-Like Peptide-1 Analogue and Renin Inhibitor on the Binding and Regulation of GLP-1 Receptor in Type 1 Diabetic Rat Hearts  

UK PubMed Central (United Kingdom)

This study focuses on the effects of long-term renin-angiotensin system suppression and/or incretin mimetic therapies on the regulation and binding affinity of GLP-1 to its receptor in the coronary...Full Text Available

2011-01-01

149

Achieving cholesterol targets by individualizing starting doses of statin according to baseline low-density lipoprotein cholesterol and coronary artery disease risk category: The CANadians Achieve Cholesterol Targets Fast with Atorvastatin Stratified Titration (CanACTFAST) study  

UK PubMed Central (United Kingdom)

BACKGROUND:Despite an increasing body of evidence on the benefit of lowering elevated levels of low-density lipoprotein cholesterol (LDL-C), there is still considerable concern that...Full Text Available

2010-02-01

150

A comparison of the acute haemodynamic effects of nisoldipine and nifedipine during treatment with atenolol in patients with coronary artery disease.  

UK PubMed Central (United Kingdom)

1. The acute haemodynamic effects of intravenous nisoldipine (1, 2, 4 microg kg(-1)) and nifedipine (2.5, 5, 10 microg kg(-1)) were compared in a randomised, within-patient crossover study. Fifteen...Full Text Available

1993-10-01

151

MRI with pathogenic correlation of small renal cell carcinoma  

Energy Technology Data Exchange (ETDEWEB)

MRI, ultrasonography and angiography were performed on 24 cases with small renal cell carcinoma, and data were compared with pathological architecture type. An average diameter of cancer was 20.8 mm (10-30 mm). Each tumor was pathologically classified into four architecture types: alveolar type (15 cases), papillary type (5 cases), tubular type (3 cases) and cystic type (1 case). In comparison with renal cortex alveolar type renal cell carcinoma showed equal or low signal in T1-weighted images and equal or high signal in T2-weighted images. Papillary and tubular types showed high signal in T1-weighted images, and low signal in T2-weighted images. In alveolar type, many cases showed equal echo in ultrasonography and hypervascularity in angiography, and in papillary and tubular types, many cases showed high echo and hypovascularity. There were many cases with papillary type small cell carcinoma which showed low signal intensity of T2-weighted ...

1999-11-01

152

Localization of islet cell tumors by dynamic CT: comparison with plain CT, arteriography, sonography, and venous sampling  

Energy Technology Data Exchange (ETDEWEB)

Ten patients with suspected islet cell tumors (seven with possible gastrinomas, three with insulinomas) underwent diagnostic evaluation with dynamic CT scanning, routine CT scanning, angiography, and sonography. Venous sampling was also performed in selected instances. Nine sites of gastrinoma and three insulinomas were confirmed surgically in eight patients. Two patients had negative surgical explorations. Routine CT demonstrated five of the nine gastrinomas and one of two insulinomas. Angiography was positive in six of nine gastrinomas and all three insulinomas. Sonography showed only two of the nine gastrinomas and two of the three insulinomas. Dynamic CT scanning demonstrated three additional lesions (two gastrinomas, on insulinoma) not visible on routine CT scanning. Although most of these lesions were visible arteriographically, dynamic CT scans at the appropriate level localized the pathology in the transverse plane and greatly aided in ...

1984-09-01

153

Experience with abdominal gamma imaging in patients with bleeding of the lower digestive tube  

International Nuclear Information System (INIS)

This study concerns our experiences with abdominal gamma imaging using Tc-99m colloid and with abdominal angiography using Tc-99m-pyrophosphate labelled erythrocytes ''in vivo'' based on the modified technique described by Callahan. The dynamic or perfusion phase was first performed, then the static phase during which for the first two hours scans were taken every 15 minutes and thereafter every 4-6 hours. The routine image corresponds to the first, although it was necessary at times to take oblique projections. The study was felt to be accomplished after 48 hours upon observing no extravasation of radioactive material in the abdominal region, or upon detecting a bleeding site. The investigation was performed on 11 patients, 8 having positive scans of abdominal extravasation, later confirmed in 6 by endoscopy and by surgery. In 2, the presence of salmonelosis was shown by laboratory analysis. Endoscopy and angiography XR are both invasor ...

1985-04-25

154

Diagnostic features of intrahepatic cholangiocarcinoma according to the gross type classification  

International Nuclear Information System (INIS)

Forty resected cases of intrahepatic cholangiocarcinoma were classified into four types according to the gross appearance; type I: mass forming type (n=8), type II: mass forming with periductal infiltrating type (n=20), type III: periductal infiltrating type (n=9) and type IV: intraductal growth type (n=3). Diagnostic features of these four types were studied. Peripheral enhancement was a common angiographic feature and tumor stains were recognized in 88%, 20%, 0%, 33%, respectively. Angiography and dynamic computed tomography (D-CT) were useful in differential diagnosis with hepatocellular carcinoma. Accuracy rate in diagnosis of portal vein involvement by angiography and D-CT was 82% and 91%, respectively. MRI was more useful in tumor detection than D-CT in cases with attenuation difference, in 55% of type II and in 75% of type III. Increase of arterial involvement, biliary tract involvement and portal vein involvement, incidence of lymph ...

1998-08-01

155

Computed tomography (CT) in renal trauma  

International Nuclear Information System (INIS)

CT scans were performed on 25 patients suspected of sustaining ranal trauma. The utility of CT in both detecting renal damage and appraising the gravity of injuries was assessed. Nowadays, in fact, nephrectomy or reserved for lesions devastanting the kidney parenchyma or rupturing the renal pedicle; so it is very important to identyfy both the purposes of a better planned therapeutic approach. CT does both, being more accurate than urography in the detection of renal fractures, intra or extraparenchymal hematomas and contrast media extravasation. Urography very often shows aspecific lesion patterns and sometimes it is also falsely negative. In the present series CT was more reliable than angiography itself, particulary in the diagnosis of extra-renal hematic collections, contrast media extravasation and injuries to the other abdominal organs. Although CT may arouse the suspicion of and sometimes correctly diagnose vascular lesions, such as renal infarction, ...

1987-01-01

156

Clinical and tomographic aspects of macular microholes; Aspectos clinicos e tomograficos dos microburacos maculares  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To describe the clinical aspects and evaluate optical coherence tomography of macular microholes. Methods: Seven patients were assessed (8 eyes) with microholes of the macula. All patients underwent complete eye examination, fundus photography, fluorescent angiography and OCT-3 imaging. Results: Ages ranged from 26 to 69 years. Six patients were female (85.7%) and five of them had microhole in the right eye. The presenting symptom was decrease in visual acuity (71.3%) and central scotoma in (14.3%). Five eyes (71.4%) had no defects shown by fluorescent angiography. A defect in the outer retina was demonstrated in all eyes on optical coherence tomography. The lesions were nonprogressive. Conclusion: Macular microholes are small lamellar defects in the outer retina. The condition is nonprogressive, generally unilateral and compatible with good visual acuity. Fundus biomicroscopy associated with an optical coherence tomography are the ...

2009-07-01

157

A computer-assisted method for 3D subtraction angiography based on spiral CT  

International Nuclear Information System (INIS)

The objective of this study was to develop a method for 3D subtraction CT angiography and to optimize the visualization after semiautomatic segmentation. Ten patients with aneurysms of the abdominal aorta were examined using spiral CT. To reconstruct the vessels, as well as adjacent organs such as the liver and kidneys, one image data volume was acquired before and after injection of the contrast agent. The CT scans were obtained with a Siemens Somatom Plus 4. To improve the results of automatic segmentation, as well as visualization by maximum intensity projection (i.e. removal of bony structures), subtraction of both image volumes is necessary. However, small translation shifts disturb the subtraction process and produce artificial contours. To calculate the disparities along the three coordinate axes of two corresponding image volumes, a cepstrum filter is applied to a pair of image volumes. After detection of the disparities, which manifest as bright spots, the ...

158

Radiodiagnosis of Ewing's sarcoma of the rib in children  

International Nuclear Information System (INIS)

The results of the examination of 23 children with Ewing's sarcoma of the rib were analyzed: panoramic chest X-rays in 4 projections, spot radiographs of the robs, superexposed pictures, laterograms, urography, angiography, computerized tomography, and scanning of the skeleton. Causes of diagnostic errors made at the first consultation by a physician, were identified. Peculiarities of X-ray signs of tumors of this site in children were studied. Diagnostic difficulties in tumors complicated by pleurisy and in tumors of small sizes with extrapleural growth were shown. Inclusions in the extraoseous tumor component were noted in 8.7% of the cases.

159

Radiation exposure of patients and operators during interventional radiology  

International Nuclear Information System (INIS)

Surface doses received by patients and operators were measured during 30 interventional radiological procedures (ten percutaneous transhepatic biliary drainages, ten percutaneous nephrostomies, ten percutaneous transluminal angioplasties). In addition, organ doses to the patient were determined using an Alderson-Rando phantom. These served as a basis for calculating the so-called somatic dose indices. It was found that the somatic radiation risk to the patient is relatively small despite prolonged periods of fluoroscopy. However, exposure of the hands and lenses of the operator could easily reach the limits thought acceptable while carrying out these procedures with additional angiography. (orig).

1986-01-01

160

Noninvasive follow-up of GDC-treated saccular aneurysms by MR angiography  

International Nuclear Information System (INIS)

The aim of this study was to determine sensitivity and specificity of magnetic resonance angiography (MRA) for the assessment of durable occlusion of intracranial aneurysms with Guglielmi detachable coils (GDC) and to point out the influence of MRA results in re-intervention strategies. Forty-five patients with 54 aneurysms that were previously treated by endovascular occlusion with GDC were selected for this study. All patients underwent digital subtraction angiography (DSA) and MRA examinations on the same day. The time-of-flight MRA studies were performed on a 1-T scanner. The MRA images were first read by radiologists who were not aware of the DSA results. In a second consensus reading by the neuroradiologists who had performed all interventional procedures of this series, the decision was made as to whether re-treatment was necessary. The distribution of aneurysm sizes, configurations and treatment results were sufficient for an unbiased ...

2001-09-01

161

Role of Quantitative Bone Scanning in the Assessment of Bone Turnover in Patients With Charcot Foot  

UK PubMed Central (United Kingdom)

OBJECTIVETo assess the new quantitative bone scan parameters as markers of Charcot neuroosteoarthropathy (CNO) activity.RESEARCH DESIGN AND METHODSForty-two...Full Text Available

2010-02-01

162

Quantitative structure-activity relationships of insecticides and plant growth regulators: comparative studies toward understanding the molecular mechanism of action.  

UK PubMed Central (United Kingdom)

Emphasis was put on the comparative quantitative structure-activity approaches to the exploration of action mechanisms of structurally different classes of compounds showing the same type of activity...Full Text Available

1985-09-01

163

Quantitative evaluation of siRNA delivery in vivo  

UK PubMed Central (United Kingdom)

Effective small interfering RNA (siRNA)–mediated therapeutics require the siRNA to be delivered into the cellular RNA-induced silencing complex (RISC). Quantitative information of this essential...Full Text Available

2010-12-01

164

Quantitation of Antibody to Non-Hemagglutinating Viruses by Single Radial Hemolysis: Serological Test for Human Coronaviruses  

UK PubMed Central (United Kingdom)

A single radial hemolysis test was developed for quantitation of specific antibody to non-hemagglutinating viruses. With the human coronaviruses as models, this test utilizes the binding properties...Full Text Available

1977-06-01

165

Mapping Quantitative Trait Loci Controlling Milk Production in Dairy Cattle by Exploiting Progeny Testing  

UK PubMed Central (United Kingdom)

We have exploited ``progeny testing'' to map quantitative trait loci (QTL) underlying the genetic variation of milk production in a selected dairy cattle population. A total of 1,518 sires, with progeny...Full Text Available

1995-02-01

166

From Classical Genetics to Quantitative Genetics to Systems Biology: Modeling Epistasis  

UK PubMed Central (United Kingdom)

Gene expression data has been used in lieu of phenotype in both classical and quantitative genetic settings. These two disciplines have separate approaches to measuring and interpreting epistasis, which...Full Text Available

2008-03-01

167

Fabp7 Maps to a Quantitative Trait Locus for a Schizophrenia Endophenotype  

UK PubMed Central (United Kingdom)

Deficits in prepulse inhibition (PPI) are a biological marker for schizophrenia. To unravel the mechanisms that control PPI, we performed quantitative trait loci (QTL) analysis on 1,010 F2 mice derived...Full Text Available

2007-11-01

168

Evaluation of the ERETIC Method as an Improved Quantitative Reference for 1H HR-MAS Spectroscopy of Prostate Tissue  

UK PubMed Central (United Kingdom)

The Electronic REference To access In vivo Concentrations (ERETIC) method was applied to 1H HR-MAS spectroscopy. The accuracy, precision, and stability of ERETIC as a quantitative...Full Text Available

2009-03-01

169

SIMV: An Application of Mathematical Modeling in Ventilator Management  

UK PubMed Central (United Kingdom)

SIMV (simulation and modeling of ventilation) is a quantitative system for the mathematical modeling and simulation of pulmonary...Full Text Available

1989-11-08

171

Interest of quantitative bone scintigraphy  

International Nuclear Information System (INIS)

French 1979. p. 4.35-4.48. France Granier, R. Bittoun, J. Doury, P. Pattin,

175

Quantitative phase imaging using hard x-rays  

International Nuclear Information System (INIS)

The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.

2009-02-01

176

{sup 99m}TC tetrofosmin cardiac tomography after nitrate administration in patients with coronary artery disease and left ventricular dysfunction; Tomografia cardiaca {sup 99m}Tc tetrofosmina dopo somministrazione di nitrati in pazienti con cardiopatia ischemica e disfunzione ventricolare sinistra  

Energy Technology Data Exchange (ETDEWEB)

The work examines twenty-two patients with coronary artery disease, previous myocardial infarction and LV dysfunction, using the technetium-99m ({sup 99m}Tc) tetrofosmin (SPECT) associated with nitrate administration in the detection of hypoperfused but still viable myocardium. The method allows the detection of this disease. [Italian] Il lavoro analizza i risultati degli esami condotti su 22 pazienti con cardiopatia ischemica cronica e ridotta funzione ventricolare sinistra sottoposti a tomografia computerizzata con emissione di fotone singolo (SPECT) cardiaca con tecnezio-99m ({sup 99m}Tc) tetrofosmina associata alla somministrazione di nitrati nella differenziazione tra tessuto miocardico ipoperfuso ma ancora vitale e tessuto miocardico necrotico. La metodologia usata consente di identificare la presenza di tessuto miocardico vitale in territori vascolari severamente ipoperfusi.

2000-04-01

177

Effects of carbon monoxide on myocardial ischemia  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to determine whether low doses of carbon monoxide (CO) exacerbate myocardial ischemia during a progressive exercise test. The effect of CO exposure was evaluated using the objective measure of time to development of electrocardiographic changes indicative of ischemia and the subjective measure of time to onset of angina. Sixty-three male subjects (41-75 years) with well-documented coronary artery disease, who had exertional angina pectoris and ischemic ST-segment changes in their electrocardiograms, were studied. Results from three randomized, double-blind test visits (room air, low and high CO) were compared. The effect of CO exposure was determined from the percent difference in the end points obtained on exercise tests performed before and after a 1-hr exposure to room air or CO. A significant dose-response relationship was found for the individual differences in the time to ST end point and angina for the pre-versus postexposure ...

1991-02-01

178

Visualization of right atrial appendix by Thallium-201 myocardial scintigraphy: concise communication  

Energy Technology Data Exchange (ETDEWEB)

The atrial myocardium has been barely visible with thallium-201 myocardial scintigraphy. This is probably related to the difference in size, distance from anterior chest wall, and small coronary blood flow of the atrium, compared with the ventricle. We have encountered eight cases of visualization of the right atrial appendix (RAA). The RAA was identified from multiple projections in all cases and sometimes confirmed by radionuclide angiocardiography. Evidence derived from ECG, chest radiographs, and cardiac catheterization, indicated that the most important factor in the visualization might be the displacement of the RAA to a more anterior position.

1980-10-01

179

Novel snake venom ligand dendroaspis natriuretic peptide is selective for natriuretic peptide receptor-A in human heart: downregulation of natriuretic peptide receptor-A in heart failure.  

Science.gov (United States)

The natriuretic peptides are considered to be cardioprotective; however, their receptors have not been identified in human myocardium using radiolabeled analogs. Dendroaspis natriuretic peptide (DNP) has been recently identified as a new member of this peptide family and is thought to be less susceptible to enzymatic degradation. Therefore, we have developed the novel radiolabeled analog [125I]-DNP and used this to localize high-affinity (K(D)=0.2 nmol/L), saturable, specific binding sites in adult human heart (n=6) and coronary artery (n=8). In competition binding experiments, atrial natriuretic peptide and brain type natriuretic peptide had greater affinity for [125I]-DNP binding sites than C-type natriuretic peptide and the natriuretic peptide receptor (NPR)-C ligand, cANF. This rank order of potency suggested binding of [125I]-DNP was specific to NPR-A. Messenger RNA encoding NPR-A was identified in left ventricle and coronary artery smooth ...

2006-06-15

180

The value of cardiac catheterization and cineangiography in infantile lobar emphysema  

International Nuclear Information System (INIS)

Lobar emphysema is an uncommon cause of respiratory distress in infancy. Congenital heart disease is seen in about 20% of the patients with infantile (congenital) lobar emphysema. We described six infants with lobar emphysema. In three of them a congenital heart disease was demonstrated by cardiac catheterization and cineangiography; two had a tetralogy of Fallot with right aortic arch and the third infant a ventricular septal defect. The pulmonary angiography showed stretching of the arteries with very poor filling of the peripheral arteries and a characteristic smaller pulmonary vein in the affected lobe. In all the six patients the pulmonary artery pressure was normal. All the patients underwent lobectomy with good results. We feel that a preoperative cardiac catheterization and cineangiography is of value in this very sick group of infants. (orig.).

181

Targeted drug delivery under MRI guidance  

British Library Electronic Table of Contents (United Kingdom)

The main goal of local drug delivery is to increase the concentration of a specific therapeutic agent in a target tissue with minimal nontarget distribution. Compared to systemic therapy, local drug delivery provides a high level of therapeutic efficacy with minimal systemic effects. The current primary imaging modality for drug delivery has been x-ray angiography, but it has major limitations including anatomical ambiguity and inability to visualize the targeted tissues. Due to these inherent problems, MR guidance has been explored as an alternative imaging modality for guiding and monitoring of drug therapy. Recently, interventional MR (XMR) systems have been implemented that have both dual x-ray and MRI capabilities in a single suite and allow for real-time interventional procedures to ...

2008-01-01

182

Determination of the optimal speed of rotational display through an 180 degree arc in rotatostereoradiography and MR angiography  

International Nuclear Information System (INIS)

Rotatostereoradiographic (RSRG) images are displayed in an oscillating, rotational manner. While reviewing these rotating images, the radiologist may become psychologically irritated by the rotation. A rapidly rotating display of linear subjects gives one three-dimensional depth information. This three-dimensional sense is lost if the rotation speed is too slow. The authors of this paper determined the slowest possible rotating display speed that allows perception of three-dimensional depth information minimizing psychological irritation. In the RSRG device (Shimadzu ROTATO-360), an x-ray tube coupled with an image intensifier rotates through a 180 degrees arc in 1.8 or 2.25 seconds. Both rotation times could be doubled. The images were displayed at four different speeds, covering the 180 degrees arc in 1.8, 2.25, 3.6, and 4.5 seconds.

1990-11-25

183

CF findings of bowel infarction in 56 surgical patients, 5 of whom with reversible ischemia  

International Nuclear Information System (INIS)

Bowel infarction is a rare and typical condition of the elderly; despite improvements in diagnostic imaging and vascular surgery, bowel infarction remains a major cause of acute abdomen, with mortality rates ranging 70-80%. Diagnosis on often late because clinical sings, laboratory data and radiologic findings are a specific. The authors investigated radiographic and particular CT patterns of intestinal infraction in 56 patients submitted to surgery within 12 hours of admission. We also report the CT findings of 5 of these patients who had reversible mesenteric ischemia. CT is more sensitive than radiography and does not exhibit the limitations of angiography (i.e., invasiveness, radiation exposure an complex organization. Therefore CT can presently be considered the method of choice in patients with suspected bowel infarction.

1999-04-01

184

Acute femoral neck fracture  

International Nuclear Information System (INIS)

Ten patients with traumatic femoral neck fracture were studied with MR imaging (0.5 T, Magnetom, Siemens): unenhanced (multiecho, TR/TE = 1,600/30--240 [repetition time/echo time, msec]; gradient echo, TR/TE = 315/14, #theta# = 90 degrees) and Gd-DTPA enhanced (0.1 mM/kg body weight, Magnevist, Schering; gradient echo, TR/TE = 315/14, #theta# = 90 degrees). MR images were compared with clinical-radiographic findings. Digital subtraction angiography of the femoral head (FH) in five patients showed complete interruption of blood supply to the FH in three patients (signal intensity of FH did not increase on postcontrast images) and intact FH arteries in two patients (FH signal increased on postcontrast images, as did the healthy-side signal).

185

A method of stereotaxic localization adopted for conventional and digital radiography  

International Nuclear Information System (INIS)

A method for the determination of stereotaxic coordinates in radiography, e.g. angiography, pneumoencephalography or digital vascular radiography, is described. A special localization frame containing radiopaque structures and scales defines a diagnostic coordinate system. This frame is fixed to the X-ray-table prior to the radiographic procedure and two projections are obtained at arbitrary angles to each other. The focus-film distances do not have to be fixed. The target coordinates are then determined either by a simple graphical procedure or with the use of a digitizing x-y-table, by a computer. With the computer method the films are placed on the digitizing table and the target and a few reference points are marked using a cursor. From the relative positions the computer calculates the coordinates. With the special head fixation system, coordinates of structures visualized in radiographic examinations can be transferred to various therapeutic or diagnostic ...

1986-01-01

186

Quantitative dissolution of (U, Pu)O_2 MOX (0.4% to 44% PuO_2) using microwave heating technique  

International Nuclear Information System (INIS)

AFFF has fabricated the (U, Pu)O_2 mixed oxide fuels for PHWRs, BWRs, PFBRs and FBTRs. The quantitative dissolution of the fuel samples are required within time for accurate determination of uranium-plutonium in chemical quality control laboratory. This paper describes the use of microwave heating technique in quantitative dissolution of (U, Pu)O_2 MOX (from 0.4% to 44% PuO_2). (author)

2011-02-22

187

The application of 64 multidetector CT angiography in the evaluation of carotid stenosis and follow-up of carotid endarterectomy and percutaneous transluminal stenting  

International Nuclear Information System (INIS)

Objective: To evaluate the diagnostic value of 64 multidetector-row CT angiography for internal carotid artery (ICA) stenosis and the application in the follow-up of carotid endarterectomy and percutaneous transluminal stenting. Methods: Forty transient ischemic attack (TIA) patients with interpretable CTA and DSA of the cervical carotid arteries were selected from May 2005 to December 2005. This yielded a total of 80 vessels. The CTA curved planar reformations (CPR) and DSA images referenced to the distal cervical internal carotid were graded by two senior neuroradiologists blindly, according to the North American Symptomatic Carotid Endarterectomy Trial (NASCET) guidelines. The paired-t test was used to verify the statistical significant difference between pre-operating and post-operating of carotid endarterectomy or percutaneous transluminal stenting in measuring the vascular diameter and area of cross section using CTA. Results: When the 70% stenosis was used ...

2006-09-01

188

Percutaneous intervention in the menagement of insufficient native arteriovenous hemodialysis fistulae  

Energy Technology Data Exchange (ETDEWEB)

To determine the effectiveness and patency of percutaneous intervention in insufficient native arteriovenous hemodialysis fistulae (AVFs). Between March 1997 and September 2001, 67 cases of insufficient native AVFs resulted from central vein lesion, PTA was performed in 48 cases, and thrombolytic therapy with or without PTA in 11. In eight of the cases, in which central vein stenosis had led to the insufficency, percutaneous transluminal angioplasty (PTA) was performed, and in three of the eight, a stent was inserted. Angiography findings and complications, as well as success and patency rates in the non-thrombosis and thrombosis group, were evaluated; the central vein lesion group was analysed separately. Among 84 lesions observed at angiography, three were 54 cases of stenosis, 17 of occlusion, and 13 of combined thrombosis. The lesions were located in a proximal vein (n=51), distal vein (n=14), artery (n=6), and at the site of anastomosis ...

2002-11-01

189

Experimental and clinical studies on the usefulness and assessment of the angiographic images processed by a digital radiography system (FCR: Fuji Computed Tomography)  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film arteriogram even with a half concentration of ...

1989-06-01

190

Experimental and clinical studies on the usefulness and assessment of the angiographic images processed by a digital radiography system (FCR: Fuji Computed Tomography)  

International Nuclear Information System (INIS)

The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film arteriogram even with a half concentration of ...

1989-01-01

191

Digital subtraction angiography (DSA) using Fuji computed radiography (FCR)  

International Nuclear Information System (INIS)

A vessel phantom suitable for evaluation of spatial and contrast resolution of FCRDSA (Fuji Computed Radiography, digital subtraction angiography) has been developed and used for determining resolution. The effects of iodine concentration, low dose exposure, and acryl thickness on the resolution were evaluated in FCRDSA, and FCRDSA images were compared with film substraction with use of this phantom. It has been proven that limitation of resolution of FCRDSA was 5 % 1 mm and about 1/4 dose exposure compared with conventional film exposure was clinically acceptable. Dye dilution method was useful to determine a program of IVDSA with imaging plate. It has been proven that time to appearance and time to peak of time-concentration curve of dye dilution method closely correlate to time to appropriate image of DSA in the neck, the chest, and the abdomen. 106 cases of IVDSA and 130 cases of IADSA using FCR in Tohoku University Hospital from January through December 1984 ...

1984-12-01

192

Assessment of arterial tumor vascularity in small hepatocellular carcinoma. Comparison between color Doppler ultrasonography and radiographic imagings with contrast medium: dynamic CT, angiography, and CT hepatic arteriography  

Energy Technology Data Exchange (ETDEWEB)

Hepatocellular carcinoma (HCC) is characterized by tumor vascularization from the hepatic artery. The objective of our work was to compare color Doppler ultrasonography (CDU), including power Doppler ultrasonography (PDU) with radiographic imagings with contrast medium in regard to the detection of the arterial tumor vascularity of small hepatocellular carcinomas (HCC). We examined 42 small HCC lesions 2 cm or less in diameter in 37 patients for arterial tumor vascularity by conventional CDU, PDU, dynamic computed tomography (dCT), digital subtraction angiography (DSA), and CT hepatic arteriography (CTA). Color images were detected in 25 (59.5%) and 28 (66.7%) of the 42 lesions with conventional CDU and PDU, respectively, and tumor vascularity was detected in 26 (61.9%) by dCT, 23 (54.8%) by DSA, and 29 (69.0%) by CTA. Tumor vascularity could be detected in 51.9% by PDU and CTA, more than by conventional CDU, dCT, and DSA (44.4, 44.4, and 33.3%, respectively) in ...

2000-10-01

193

3D time-of-flight MR angiography of the intracranial vessels: optimization of the technique with water excitation, parallel acquisition, eight-channel phased-array head coil and low-dose contrast administration  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study is three folds: to compare the eight-channel phased-array and standard circularly polarized (CP) head coils in visualiazation of the intracranial vessels, to compare the three-dimentional (3D) time-of-flight (TOF) MR angiography (MRA) techniques, and to define the effects of parallel imaging in 3D TOF MRA. Fifteen healthy volunteers underwent 3D TOF MRA of the intracranial vessels using eight-channel phased-array and CP standard head coils. The following MRA techniques were obtained on each volunteer: (1) conventional 3D TOF MRA with magnetization transfer; (2) 3D TOF MRA with water excitation for background suppression; and (3) low-dose (0.5 ml) gadolinium-enhanced 3D TOF MRA with water excitation. Results are demonstrating that water excitation is a valuable background suppression technique, especially when applied with an eight-channel phased-array head coil. For central and proximal portions of the intracranial arteries, unenhanced TOF MRA ...

2004-11-01

194

Wind and Wave Forcing of Longshore Currents Across a ...  

Science.gov (United States)

... These assumptions are quantitatively investigated by calculating tie icldti\\e inportance of ... A modified lon-shore current model is used to study the ...

1988-06-01

195

The interpretation of systematic reviews with meta-analyses: an objective or subjective process?  

UK PubMed Central (United Kingdom)

BackgroundDiscrepancies between the conclusions of different meta-analyses (quantitative syntheses of systematic reviews) are often ascribed to methodological differences. The objective...Full Text Available

196

Single photon emission tomography of the pituitary: preliminary communication.  

UK PubMed Central (United Kingdom)

A specific application of single photon emission tomography to the relative quantitation of the pituitary region is described together with the results obtained in 19 patients with pituitary adenoma...Full Text Available

1981-09-01

197

Simultaneous recognition and segmentation of cells: application in C.elegans  

UK PubMed Central (United Kingdom)

Motivation: Automatic recognition of cell identities is critical for quantitative measurement, targeting and manipulation of cells of model animals at single-cell resolution. It has been...Full Text Available

2011-10-15

198

STR Training Materials  

Science.gov (United States)

Typing Workshop": [Introductions] [Intro, DNA Basics, and Historical Perspective] [DNA Extraction] [Validation and QA/QC] [DNA Quantitation] [PCR Amplification] [STR Loci and Kits]...

2011-04-29

199

Quantitative morphology and water distribution of bronchial biopsy samples.  

UK PubMed Central (United Kingdom)

BACKGROUND: An approach to the study of the pharmacokinetics of drugs in the lung is to measure their concentrations in bronchial biopsy specimens. The main criticism of this technique is that bronchial...Full Text Available

1992-07-01

200

Quantitative investigation of the crowding effect of Hymenolepis diminuta in Rattus norvegicus  

Science.gov (United States)

This laboratory exercise demonstrates some basic principles in parasitology by using experimental studies of the relationship of Hymenolepis diminuta with its rodent host.

2000-01-01

201

Quantitative easing works: Lessons from the unique experience in Japan 2001-2006  

British Library Electronic Table of Contents (United Kingdom)

Abstract: The current financial crisis has now led most major central banks to rely on quantitative easing. The unique Japanese experience of quantitative easing is the only experience which enables us to judge this therapy's effectiveness and the timing of the exit strategy. In this paper, we provide a new empirical framework to examine the effectiveness of Japanese monetary policy during the ''lost'' decade and quantify the effect of quantitative easing on Japan's activity and prices. We combine advantages of Markov-switching VAR methodology with those of factor analysis to establish two major findings. First, we show that the decisive change in regime occurred in two steps: it crept out from late 1995 and established itself durably in February 1999. Second, we show for the first time th...

2011-01-01

202

Quantitative cerebral blood flow with Optical Coherence Tomography  

UK PubMed Central (United Kingdom)

Absolute measurements of cerebral blood flow (CBF) are an important endpoint in studies of cerebral pathophysiology. Currently no accepted method exists for in vivo longitudinal...Full Text Available

2010-02-01

203

Quantitative Spectroscopy of Photospheric-Phase Type II SN  

Science.gov (United States)

... and high-quality photospheric-phase Type II SN spectra to constrain core- collapse SN explosions, massive star evolution, and distances in the Universe ...

204

Preliminary exploration of online social support among adults with asthma  

UK PubMed Central (United Kingdom)

OBJECTIVEEvaluate the qualitative and quantitative differences between moderated and unmoderated on-line social support groups focused on asthma.DESIGNA...Full Text Available

2003-01-01

205

Prediction of Chemicals Ecotoxicity  

International Science & Technology Center (ISTC)

Computer-Aided Prediction of Chemical Ecotoxicity on the basis of Quantitative Structure-Activity Relationships with the Use of Physico-Chemical Descriptors, Including H-bond Parameters

207

Gallbladder function and dynamics of bile flow in asymptomatic gallstone disease  

UK PubMed Central (United Kingdom)

AIM: To investigate the effects of gallbladder stones on motor functions of the gallbladder and the dynamics of bile flow in asymptomatic gallstone disease.METHODS: Quantitative hepatobiliary...Full Text Available

2009-06-14

208

Fractal parameters and vascular networks: facts & artifacts  

UK PubMed Central (United Kingdom)

BackgroundSeveral fractal and non-fractal parameters have been considered for the quantitative assessment of the vascular architecture, using a variety of test specimens and of computational...Full Text Available

209

Condition Monitoring of Aircraft by Quantitative Filter Debris ...  

Science.gov (United States)

... 15- Two Sigma from Mean S..... I ..... 2 ... only a small number of engine filter debris samples ... comprehensive, but it does point out that ...

1996-04-01

210

Barriers to Initiating Depression Treatment in Primary Care Practice  

UK PubMed Central (United Kingdom)

OBJECTIVE AND DESIGNThis study used qualitative and quantitative methods to examine the reasons primary care physicians and nurses offered for their inability to initiate guideline-concordant...Full Text Available

2002-02-01

211

Apolipoproteins in rat serum and renal lymph.  

UK PubMed Central (United Kingdom)

The concentration of apolipoproteins was measured by quantitative immunoelectrophoresis in rat serum, in the lipoprotein-free ultracentrifugal fraction (density greater than 1.21) of serum, and in renal...Full Text Available

1976-05-01

212

A gravitational diffusion model without dark matter  

UK PubMed Central (United Kingdom)

In this model, without dark matter, the flat rotation curves of galaxies and the mass-to-light ratios of clusters of galaxies are described quantitatively. The hypothesis is that the agent of gravitational...Full Text Available

1998-03-31

213

The role of insulin therapy and glucose normalisation in patients with acute coronary syndrome  

British Library Electronic Table of Contents (United Kingdom)

Patients with acute myocardial infarction (AMI) and diabetes mellitus, as well as patients admitted with elevated blood glucose without known diabetes, have impaired outcome. Therefore intensive glucose-lowering therapy with insulin (IGL) has been proposed in diabetic or hyperglycaemic patients and has been shown to improve survival and reduce incidence of adverse events. The current manuscript provides an overview of randomised controlled trials investigating the effect of IGL. Furthermore, systematic glucose?insulin?potassium infusion (GIK) has been studied to improve outcome after AMI. In spite of positive findings in some early studies, GIK did not show any beneficial effects in recent clinical trials and thus this concept has been abandoned. While IGL targeted to achieve normoglycaemi...

2011-01-01

214

The Impact of Proactive Chronic Care Management on Hospital Admissions in a German Senior Population  

British Library Electronic Table of Contents (United Kingdom)

Abstract An increase in chronic disease prevalence is contributing to health care cost growth and decreased quality of life in industrialized nations worldwide. Inadequate management of chronic diseases is a leading cause of hospitalizations and, thus, avoidable expenditures. In this study, we evaluated the impact of nurse-delivered care calls, the primary intervention of a proactive chronic care management (CCM) program, in a population aged 65 and older in Germany. In this analysis, hospital admission rates were evaluated among program enrollees who were diagnosed with diabetes, heart failure, coronary heart disease, or chronic obstructive pulmonary disease. The Intervention group comprised those members who participated in care calls (n?=?13,486), whereas the Comparison group included e...

2011-01-01

215

Serial Intravascular Ultrasound Analysis of the Impact of Myocardial Bridge on Neointimal Proliferation After Coronary Stenting in Patients with Acute Myocardial Infarction  

British Library Electronic Table of Contents (United Kingdom)

Background: Mechanisms underlying the association between myocardial bridge (MB)-stenting and in-stent restenosis (ISR) are still unclear. Objective: To assess the impact of MB on ISR using intravascular ultrasound (IVUS). Methods: In the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) trial, 100 left anterior descending artery (LAD) culprit lesions (79 treated with paclitaxel-eluting stents [PES] and 21 treated with bare metal stents) were imaged with serial IVUS immediately postprocedure and at 13 months. Results: At baseline the LAD stent extended into the MB segment beyond the culprit lesion in seven patients (MB-stent group). In the remaining 93 patients the LAD stent was implanted only in the culprit lesion without extending into t...

2010-01-01

216

Plasma carotenoids and risk of acute myocardial infarction in the Singapore Chinese Health Study  

British Library Electronic Table of Contents (United Kingdom)

Background and aimModification of low-density lipoprotein due to oxidative stress is essential in the development of coronary atherosclerosis. Data of specific carotenoids except b-carotene on cardioprotective effects in humans are limited. Methods and resultsThis study examined the associations between plasma concentrations of specific carotenoids and incidence of acute myocardial infarction. The study included 280 incident cases of acute myocardial infarction and 560 matched controls nested within the Singapore Chinese Health Study, a prospective cohort of 63,257 Chinese men and women aged 45-74 years old enrolled in 1993-1998 in Singapore. Retinol and carotenoids in prediagnostic plasma were quantified using high-performance liquid chromatography. High levels of plasma b-cryptoxanthin a...

2011-01-01

217

PET and MRI in cardiac imaging: from validation studies to integrated applications  

International Nuclear Information System (INIS)

Positron emission tomography (PET) is the gold standard for non-invasive assessment of myocardial viability and allows accurate detection of coronary artery disease by assessment of myocardial perfusion. Magnetic resonance imaging (MRI) provides high resolution anatomical images that allow accurate evaluation of ventricular structure and function together with detection of myocardial infarction. Potential hybrid PET/MR tomography may potentially facilitate the combination of information from these imaging modalities in cardiology. Furthermore, the combination of anatomical MRI images with the high sensitivity of PET for detecting molecular targets may extent the application of these modalities to the characterization of atherosclerotic plaques and to the evaluation of angiogenetic or stem cell therapies, for example. This article reviews studies using MRI and PET in parallel to compare their performance in cardiac applications together with the potential benefits ...

2009-03-01

218

Health effects of the Chernobyl accident  

Energy Technology Data Exchange (ETDEWEB)

The results of nine years of study of the 237 patients who suffered from acute radiation syndrome (ARS) as a consequence of the Chernobyl accident are reported. Thirty-eight of these patients have died, 28 in the acute period in 1986, 5 in 1987-90 and 5 in 1992-93. The reasons for death show no clear tendencies. They include: gangrene of the lung, organic disease of the brain and spinal chord, hypoplasia of haematopoeisis, coronary heart disease, sarcoma and an automobile accident. Investigations have been carried out on an annual obligatory basis of the patients` haemopoietic, immune, nervous and endocrine systems. An analysis of the data is presented. Histograms are included showing the incidence of digestive tract, nervous system, respiratory and cardiovascular disorders, the frequency and degree of disablement and serum prolactin concentration. The types of skin damage sustained by 39 of the patients are listed. (6 figures, 3 tables). (UK).

1995-12-31

219

As time goes by? The fallacy of thrombolysis in STEMI networks  

British Library Electronic Table of Contents (United Kingdom)

Primary percutaneous coronary intervention (PPCI) is superior to thrombolysis (TL) as reperfusion therapy in ST-elevation myocardial infarction (STEMI). TL is a rapidly available, but semi-effective therapy (effective reperfusion in 50% of patients only), whereas PPCI is a potentially delayed, but highly effective therapy (effective reperfusion in >90%). Since TL loses its efficacy beyond 2?3?h after symptom onset, it is a significant reperfusion alternative to PPCI in early presenters only. The individual decision to treat an early presenter with PPCI or TL requires the evaluation of the time delay between potential start of TL or PPCI, the PCI-related delay (PRD). PRD is greatest, if TL is given in the prehospital setting. Until now, prehospital TL as the most rapidly available reperfusi...

2011-01-01

220

Tracing Cadmium from Culture to Spikelet: Noninvasive Imaging and Quantitative Characterization of Absorption, Transport, and Accumulation of Cadmium in an Intact Rice Plant1[W][OA]  

UK PubMed Central (United Kingdom)

We characterized the absorption and short-term translocation of cadmium (Cd) in rice (Oryza sativa ‘Nipponbare’) quantitatively using serial images observed with a positron-emitting...Full Text Available

2010-04-01

221

Quantitative determination of atmospheric hydroperoxyl radical  

Energy Technology Data Exchange (ETDEWEB)

A method for the quantitative determination of atmospheric hydroperoxyl radical comprising: (a) contacting a liquid phase atmospheric sample with a chemiluminescent compound which luminesces on contact with hydroperoxyl radical; (b) determining luminescence intensity from the liquid phase atmospheric sample; and (c) comparing said luminescence intensity from the liquid phase atmospheric sample to a standard luminescence intensity for hydroperoxyl radical. An apparatus for automating the method is also included.

2007-10-23

222

Quantitation of Indoleacetic Acid Conjugates in Bean Seeds by Direct Tissue Hydrolysis 1  

UK PubMed Central (United Kingdom)

Gas chromatography-selected ion monitoring-mass spectral analysis using [13C6]indole-3-acetic acid (IAA) as an internal standard provides an effective means for quantitation of...Full Text Available

1989-06-01

223

Polymer depletion-induced slip near an interface  

Energy Technology Data Exchange (ETDEWEB)

A quantitative description is proposed for the depletion-induced slip thickness and velocity profile of a polymer solution near the wall-fluid interface in simple shear flow. The inhomogeneous polymer density profile at a flat wall is inserted into the equations of motion for the flow of a polymer solution near the flat wall. The theory is in quantitative agreement with simulation results. (letter to the editor)

2005-01-19

224

On the Field Dependent Surface Resistance Observed in Superconducting Niobium Cavities  

CERN Document Server

A quantitative description is presented of the non-linear current-voltage response in superconducting niobium cavities for accelerator application. It is based on a fit for a large sample of data from cavity tests of different kind. Trial functions for the surface resistance describing this non-linear relation are established by a least square data fit. Those trial functions yielding the best fit are quantitatively explained by basic physics.

2009-01-01

225

Mapping quantitative trait loci (QTL) in sheep. II. Meta-assembly and identification of novel QTL for milk production traits in sheep  

UK PubMed Central (United Kingdom)

An (Awassi × Merino) × Merino backcross family of 172 ewes was used to map quantitative trait loci (QTL) for different milk production traits on a framework map of 200 loci across all...Full Text Available

226

Localization of an anti-tumour monoclonal antibody in human tumour xenografts: kinetic and quantitative studies with the 791T/36 antibody  

International Nuclear Information System (INIS)

Studies have been performed with an anti-osteogenic sarcoma monoclonal antibody 791T/36 and human tumour xenografts to examine some of the quantitative and kinetic aspects of tumour localization. The influence of variations in tumour size and site and antibody dose on the extent and rate of specific antibody localization have been examined, together with the site of intratumoural deposition of the antibody. (UK).

227

An immunochemical approach to the study of DNA damage and repair  

Energy Technology Data Exchange (ETDEWEB)

The overall objective of this project is to produce antibodies to unique modified DNA bases and develop immunochemical assays to quantitate these lesions in damaged DNA. During this past year we have developed an antibody and chemical test to quantitate a basic sites in DNA and produced antibodies to the 8-oxopurines. This report discusses the detection of a basic sites in DNA and the preparation of antibodies to 8-hydroxyadenine and 8-hydroxyguanine.

1990-11-14

228

Quantitative bone scintigraphy in renal osteodystrophy  

International Nuclear Information System (INIS)

The need for noninvasive sensitive techniques for the diagnosis and follow-up of metabolic bone disease in dialysis patients has stimulated the author's interest in the efficacy of more detailed quantitative bone scintigraphy. Using hemodialysis to reduce elevated soft-tissue activity at scintigraphy, an attempt was made to assess the diagnostic sensitivity of quantitative bone scintigraphy as compared to qualitative bone scintigraphic, biochemical, radiographic and bone histologic studies. The second aim of these studies was to determine if one of the two major components of renal osteodystrophy is a major determinant for skeletal radiotracer uptake. The clinical observations on the efficacy and possible specificity of quantitative bone scintigraphy in the diagnosis and follow-up during treatment of renal osteodystrophy are presented briefly in this chapter. Thus, the use of scintigraphy for the routine detection and ...

229

Vladimir P. Demikhov, a pioneer of organ transplantation.  

Science.gov (United States)

Vladimir P. Demikhov was born in a Russian peasant family in 1916. As a biology student at The Moscow University in 1937, he constructed a metal artificial heart and maintained the circulation of a dog for 5.5 hours. From 1946, after his military service, he worked in the Surgical Institute of The Moscow Academy of Sciences performing heterotopic heart transplantations in dogs. In 1947, he performed the first orthotopic lung transplant. Later he performed complex cardiothoracic transplantations as well as renal and hepatic transplantations. He restarted his investigations with the artificial heart and performed coronary bypass operations in dogs. In 1954 he performed a head transplantation, for which he gained worldwide infamy. Stalinist propaganda advertised this fact as the superiority of Soviet science. In fact, it was the upper body of a smaller dog to the neck of a bigger one. The two heads could eat and drink separately. But he could not overcome the problems ...

2011-05-01

230

Natriuretic peptides in vascular physiology and pathology.  

Science.gov (United States)

Four major natriuretic peptides have been isolated: atrial natriuretic peptide (ANP), brain natriuretic peptide (BNP), C-type natriuretic peptide (CNP), and Dendroaspis-type natriuretic peptide (DNP). Natriuretic peptides play an important role in the regulation of cardiovascular homeostasis maintaining blood pressure and extracellular fluid volume. The classical endocrine effects of natriuretic peptides to modulate fluid and electrolyte balance and vascular smooth muscle tone are complemented by autocrine and paracrine actions that include regulation of coronary blood flow and, therefore, myocardial perfusion; modulation of proliferative responses during myocardial and vascular remodeling; and cytoprotective anti-ischemic effects. The actions of natriuretic peptides are mediated by the specific binding of these peptides to three cell surface receptors: type A natriuretic peptide receptor (NPR-A), type B natriuretic peptide receptor (NPR-B), and type C natriuretic ...

2008-01-01

231

Radionuclear estimation with {sup 99m}Tc-N-pyridoxyl-5-methyl-tryptophan (PMT) scintigraphy of recurrent hepatocellular carcinoma after non-surgical treatment  

Energy Technology Data Exchange (ETDEWEB)

{sup 99m}Tc-N-pyridoxyl-5-methyl-tryptophan (PMT) scintigraphy, which exhibits highly specific for the diagnosis of primary hepatocellular carcinoma (HCC), was performed for recurrent HCC following non-surgical treatment. Eighty-four patients (total 351 examinations) were selected for the study. The ability of PMT scintigraphy to diagnose recurrent HCC after treatment was compared with that of computed tomography, ultrasonography and angiography. The results showed that sixty-three (75%) of 84 cases demonstrated positive findings during our follow-up period, most of the tumors initially showing positive findings remained PMT positive when they recurred and PMT studies shortly after treatment demonstrated wider tracer uptake rather than the actual tumor area. In conclusion, PMT scintigraphy for patients with HCC after non-surgical treatment exhibited high accuracy in identifying viable HCC only for tumors indicating positive findings. (author)

1997-10-01

232

Localization of abnormal parathyroid glands using thallium-201  

Science.gov (United States)

Ectopically located parathyroid adenomas may be difficult to find during initial neck exploration. They account for over 70 percent of missed adenomas found at reexploration. Preoperative localization of parathyroid adenomas would reduce unnecessary dissection and possibly reduce the number of negative results of initial neck exploration. Before reoperative parathyroid surgery is performed, some means of localization is mandatory to detect ectopic adenomas in the neck and mediastinum. Computed tomography and ultrasonography cannot effectively evaluate the mediastinum. Angiography and venous parathyroid hormone sampling are invasive, costly, and tedious to perform. We have shown that thallium-201 will accurately localize ectopic parathyroid adenomas. All 10 adenomas found in positions not immediately adjacent to the thyroid gland were detected by thallium-201 scintigraphy. One was a mediastinal adenoma resected with a median sternotomy. Our results suggest that ...

1984-07-01

233

Lipiodol-CT findings of hepatocellular carcinoma: Correlation with lipiodol accumulation pattern and serum AFP  

Energy Technology Data Exchange (ETDEWEB)

Early diagnosis of hepatocellular carcinoma (hepatoma) along with surgical resection is the most appropriate therapeutic modality. For this purpose, there have been many reports concerning the diagnostic value of Lipiodol-CT scan. The authors selected 45 patients with hepatoma during the period of Feb.1986 to Jan. 1988 who received a conventional CT scan, hepatic angiography and a Lipiodol-CT scan. The results were as follows: 1. There was no statistical significant between serum AFP level and mass size, morphology and amount of necrosis. 2. Tumor necrosis was observed in a single massive and multinodular type when the tumor size exceeded 5 cm. 3. Pattern II on Lipiodol-CT, homogenous accumulation of Lipiodol except for the area of inner necrosis, was most frequently demonstrated, which means that a tumor mass with hypervascularity and increased blood flow will attract Lipiodol better. 4. Lipiodol-CT was superior to conventional CT in detecting small, daughter ...

1989-12-15

234

Injection-associated pain in femoral arteriography: A European multicenter study comparing safety, tolerability, and efficacy of iodixanol and iopromide  

International Nuclear Information System (INIS)

Purpose. To evaluate injection-associated pain, safety, and efficacy with the isotonic contrast medium iodixanol (Visipaque 270 mg I/ml) compared with iopromide (Ultravist 300 mg I/ml) in femoral arteriography. Methods. A multicenter, double-blind, randomized, parallel-group clinical investigation was carried out in 54 hospitals in Europe. Of the patients evaluated, 1225 received iodixanol and 1227 iopromide in conventional and/or digital subtraction angiography. Results. The iodixanol group reported statistically significantly less injection-associated pain (0.9%) than the iopromide group (9.5%) (p<0.001). Further, 4.1% in the iodixanol group experienced pain and/or severe heat sensation vs 19.8% in the iopromide group (p<0.001). In the iodixanol group, 1.8% of the patients experienced contrast-related adverse events vs 2.4% in the iopromide group (p=NS). Overall diagnostic information was optimal for 94.1% in the iodixanol group and 95.3% in the iopromide ...

1997-07-01

235

Diagnosis for the cancer extension of cholangiocarcinoma. The current status  

International Nuclear Information System (INIS)

Described is the diagnosis for the cancer extension of cholangiocarcinoma by various imaging techniques and processes to support the current surgical procedure based on preoperative biliary drainage. The cancer tends to locally extend horizontally and/or vertically and its diagnosis is important for surgical indication. For the indication, multi-detector raw CT (MDCT) and MR cholangio-pancreatography (MRCP) are useful and particularly, the former can give multi-phase (arterial, portal and delayed) images to reconstruct multiplanar (MPR) and CT angiographic 3D images, which have made the previous invasive examinations like angiography and percutaneous transportal contrasting unnecessary. MDCT and MRCP can almost complete the diagnosis of the extension. The operative procedure is decided dependently on the site of the lesion, and of which diagnosis, whether it is hepatic hilar/on upper bile duct or middle/lower ductal, is different. MDCT-MPR and MRCP are virtually ...

2010-07-01

236

Determination of left ventricular ejection fraction and wall thickness in magnetic resonance imaging at 1.0 Tesla in comparison to echocardiography and biplanar ventriculography  

International Nuclear Information System (INIS)

We compared the values of the myocardial thickness and the left ventricle diameters measured with MRI and echocardiography. The ejection fraction was compared in MRI and ventriculography. 34 patients with different heart dysfunctions were examined with MRI (FISP 2D sequence). 26 of them were also studied by echocardiography and 20 by biplane cine-ventriculography. The enddiastolic thicknesses of the left ventricular postero-lateral wall and of the septum interventriculare were measured on short axis images. An ellipsoidal modell was used for volume calculation and ejection fraction. Correlation of MRI values of thickness and ejection fraction with echocardiographi and angiographi showed r>0,8. As known for 1.56 T Imagers, the myocardial thickness in MRI was underestimated compared to echocardiography (1.4 mm#+-#1.7). The ejection fraction was underevaluated compared to ventriculography (4.5%#+-#10.1). MRI (1.0 T) accurately measures ventricular wall thickness ...

237

Computer assisted axial tomography (Emi scan) in neurologic investigation  

Science.gov (United States)

Cerebral angiography, pneumoencephalography, and radioisotope brain scan with their differing diagnostic abilities have provided the neurologist and neurosurgeon with extremely valuable diagnostic techniques. It is doubtful, however, if any of these now conventional methods had the enormous impact on the practice of neurology that computer assisted axial tomography (C.A.T.) is beginning to have. Here, for the first time, is a test which, without significant risk or discomfort, can demonstrate some normal intracranial (and intraorbital) structures, can demonstrate some normal intracranial pathology and, in many cases, can make the potentially dangerous contrast studies unnecessary. After only a few months experience with C.A.T. in a clinical setting, it has become obvious that there will have to be a reappraisal of the accepted investigative work-up of many conditions. While it is too early to have formulated strict criteria for the use of C.A.T., this paper is an ...

1974-01-01

238

Evaluation of Aution Max AX-4030 and 9UB Uriflet, 10PA Aution Sticks urine dipsticks in the automated urine test strip analysis.  

Science.gov (United States)

Abstract Background: Aution Max AX-4030, a test strip analyzer recently introduced to the market, represents an upgrade of the Aution Max AX-4280 widely employed for urinalysis. This new instrument model can allocate two different test strips at the same time. In the present study the two instruments have been compared together with the usage of Uriflet 9UB and the recently produced Aution Sticks 10PA urine strips, the latter presenting an additional test area for the measurement of urinary creatinine. Methods: Imprecision and correlation between instruments and strips have been evaluated for chemical-physical parameters. Accuracy was evaluated for protein, glucose and creatinine by comparing the semi-quantitative results to those obtained by quantitative methods. The well-known interference effect of high ascorbic acid levels on urine glucose test strip determination was evaluated, ascorbic acid influence was also evaluated on protein and ...

2011-09-26

239

Three-Dimensional Rotational Angiography of the Inferior Vena Cava as an Adjunct to Inferior Vena Cava Filter Retrieval  

International Nuclear Information System (INIS)

The objective of this study was to explore the role of three-dimensional (3-D) rotational angiography (RA) of the inferior vena cava (IVC; 3-D CV) before filter retrieval and its impact on treatment planning compared with standard anteroposterior cavography (sCV). Thirty patients underwent sCV and 3-D CV before IVC filter retrieval. Parameters assessed were: projection of filter arms or legs beyond the caval lumen, thrombus burden within the filter and IVC, and orientation of the filter within IVC. Skin and effective radiation doses were calculated. Statistical analysis was performed using paired Student t test and nonparametric McNemar's test. Standard anteroposterior cavography detected 49 filter arms or legs projecting beyond the caval lumen in 25 patients. Three-dimensional CV demonstrated 89 filter arms or legs projecting beyond the caval lumen in 28 patients. Twenty-two patients had additional filter arms or legs projecting beyond the caval lumen detected on ...

2009-01-01

240

The role of interventional radiology in management of patients with end-stage renal disease  

Energy Technology Data Exchange (ETDEWEB)

The aim of the paper is to review the role of interventional radiology in the management of hemodialysis vascular access and complications in renal transplantation. The evaluation of patients with hemodialysis vascular access is complex. It includes the radiology/ultrasound (US) evaluation of the peripheral veins of the upper extremities with venous mapping and the evaluation of the central vein prior to the access placement and radiological detection and treatment of the stenosis and thrombosis in misfunctional dialysis fistulas. Preoperative screening enables the identification of a suitable vessel to create a hemodynamically-sound dialysis fistula. Clinical and radiological detection of the hemodynamically significant stenosis or occlusion demands fistulography and endovascular treatment. Endovascular prophylactic dilatation of stenosis greater than 50% with associated clinical abnormalities such as flow-rate reduction is warranted to prolong access patency. The technical success ...

2003-05-01

241

MRI in postoperative assessment of univentricular heart disease: correlation with echocardiography and angiography; MRT in der postoperativen Diagnostik bei funktionell univentrikulaerem Herz: Korrelation zu Echokardiographie und Kardangiographie  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To determine the value of MRI in the postoperativ evaluation of a singular ventricle compared to echocardiography and cardiac catheterization. Materials and methods: Thirty-one patients (range: 6 months to 30 years) with a functional single ventricle following palliative corrective operations. Five patients had a Blalock-Taussig-Shunt, 8 patients a Glenn-Anastomosis and 18 a cavopulmonary shunt (6 with classic Fontan-Circulation, 12 with modified cavopulmonary anastomosis). The results in terms of postoperative morphologic changes were compared to percutaneous echocardiography (31/31) and cardiac catheterization (6/31). Results: Echocardiography, which was performed on all patients, could not visualize the entire length of the tunnel, the Glenn-Anastomosis or the central pulmonary arteries in 70% of the patients due to an inadequate acoustic window. MRI was able to show the entire tunnel in 11/12 patients and the central pulmonary arteries in 30/31 patients. The exact anatomy ...

2002-12-01

242

Undergraduate Instruction in Empirical Research Methods in Communication: Assessment and Recommendations  

British Library Electronic Table of Contents (United Kingdom)

This study assesses the current state of undergraduate instruction in empirical research methods in communication and offers recommendations for enhancing such instruction. Responses to an online questionnaire were received from 149 communication-related programs at four-year colleges and universities. Just over 85% of responding programs offered an empirical methods course. Although the course often covered both qualitative and quantitative methods, instruction was heavily slanted toward quantitative methods and topics common to both qualitative and quantitative inquiry. The empirical methods course was usually required for graduation, but it was typically not well integrated with the rest of the curriculum and taken late in students' undergraduate careers. Additional analyses examined st...

2011-01-01

243

Quantitative bone scintigraphy: follow-up of a femoral osteogenic sarcoma in an adolescent girl treated by chemotherapy and by massive allograft  

International Nuclear Information System (INIS)

Fifteen quantitative bone scintigraphies were performed in an adolescent girl during the follow-up of a femoral osteogenic sarcoma treated by chemotherapy and massive allograft. Three hours after injection of the radiopharmaceutical (7.4 MBq/kg of 99mTc-MDP) bone activity was measured in the inferior limbs at several regions of interest centered on the hips, femurs (proximal, middle, distal) and proximal tibias. The variations of relative bone activities A/S (ratio of corresponding counting rates between two homologous regions in the affected A and in the healthy S limb) and of absolute bone activities (expressed in counts/pixel-second) are interpreted as a function of times during treatment. The quantitative results are discussed with regard to main phenomena influencing bone activity in this particular clinical case: bone growth, chemotherapy and neo-osteogenesis in allograft.

244

Quantitation of infectious myonecrosis virus in different tissues of naturally infected Pacific white shrimp, Litopenaeus vannamei, using real-time PCR with SYBR Green chemistry  

British Library Electronic Table of Contents (United Kingdom)

The Pacific white shrimp, Litopenaeus vannamei, is the most important shrimp species in volume in world aquaculture. However, in recent decades, outbreaks of diseases, especially viral diseases, have led to significant economic losses, threatening the sustainability of shrimp farming worldwide. In 2004, Brazilian shrimp farming was seriously affected by a new disease caused by the Infectious myonecrosis virus (IMNV). Thus, disease control based on rapid and sensitive pathogen detection methods has become a priority. In this study, a specific quantitation method for IMNV was developed using real-time PCR with SYBR Green chemistry and viral load of the principal target tissues of chronically infected animals was quantified. The quantitative analysis revealed that mean viral load ranged from ...

2011-01-01

245

Nuclear medicine and imaging research: Quantitative studies in radiopharmaceutical science  

Energy Technology Data Exchange (ETDEWEB)

During the past three years the program has undergone a substantial revitalization. There has been no significant change in the scientific direction of this grant, in which emphasis continues to be placed on developing new or improved methods of obtaining quantitative data from radiotracer imaging studies. However, considerable scientific progress has been made in the three areas of interest: Radiochemistry, Quantitative Methodologies, and Experimental Methods and Feasibility Studies, resulting in a sharper focus of perspective and improved integration of the overall scientific effort. Changes in Faculty and staff, including development of new collaborations, have contributed to this, as has acquisition of additional and new equipment and renovations and expansion of the core facilities. 121 refs., 30 figs., 2 tabs.

1991-06-01

246

Groundtruth approach to accurate quantitation of fluorescence microarrays  

Energy Technology Data Exchange (ETDEWEB)

To more accurately measure fluorescent signals from microarrays, we calibrated our acquisition and analysis systems by using groundtruth samples comprised of known quantities of red and green gene-specific DNA probes hybridized to cDNA targets. We imaged the slides with a full-field, white light CCD imager and analyzed them with our custom analysis software. Here we compare, for multiple genes, results obtained with and without preprocessing (alignment, color crosstalk compensation, dark field subtraction, and integration time). We also evaluate the accuracy of various image processing and analysis techniques (background subtraction, segmentation, quantitation and normalization). This methodology calibrates and validates our system for accurate quantitative measurement of microarrays. Specifically, we show that preprocessing the images produces results significantly closer to the known ground-truth for these samples.

2000-12-01

247

Combining adjusted and unadjusted findings in mixed research synthesis  

British Library Electronic Table of Contents (United Kingdom)

Abstract Rationale, aims and objectives- Finding ways to incorporate disparate types of evidence into research syntheses has the potential to build a better evidence base for clinical practice and policy. Yet conducting such mixed research synthesis studies is challenging. Researchers have to determine whether and how to use adjusted and unadjusted quantitative findings in combination with each other and with qualitative findings. Methods- Among quantitative findings, adjustment for confounding, either via study design or statistical analysis, can be a considerable source of heterogeneity. Yet there is no consensus about the best way to synthesize findings resulting from different methods for addressing confounding. When synthesizing qualitative and quantitative findings, additional consid...

2011-01-01

248

Automation in urinalysis: evaluation of three urine test strip analysers.  

Science.gov (United States)

A clinical laboratory evaluation was conducted on the Clinitek Auto 2000, the Super Aution Analyzer and the Urotron RL9 for the determination of glucose, protein, pH, blood, ketone-bodies and bilirubin.Precision of the systems was tested using three commercial control urine materials, and reported as the percentage of times the instrument repeats a certain value. Good repeatability was obtained with all the instruments.Accuracy of the systems was evaluated by comparison with quantitative procedures, and to check agreement between methods yielding semi-quantitative and quantitative results, ranges of acceptability were defined, based on the criteria reported in a previous paper [2]. It was then found that 87.5 to 98.9% of results from the Urotron RL9 and the Clinitek Auto 2000 were acceptable. With the Super Aution Analyzer the level of agreement was apparently lower because of the higher number of concentration steps used ...

1988-01-01

249

MRI in preoperative evaluation of chronic paranasal sinusitis - a comparison with CT; MRT in der praeoperativen Diagnostik der chronischen Sinusitis im Vergleich mit der CT  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To determine the value of MRI in the preoperative evaluation of chronic paranasal sinusitis and to compare the results with CT and intraoperative findings. Method/Materials: 42 patients with clinical signs of chronic paranasal sinusitis underwent MRI after CT evaluation on one day, with subsequent functional endoscopic sinus surgery on the next day. Coronary CT was obtained with 5-mm slices and table-feed in the prone position, while MRI was performed in the supine position with coronary T{sub 2}-TSE+pd and coronary and transverse HASTE, each with 5-mm slice thickness. Aquisition time in MRI was less than 8 minutes. Two radiologists reviewed the CT and MRI scans for signs of sinusitis and detection of anatomical landmarks. The results were correlated with the intraoperative findings. Results: MRI offered no artifacts of dental work and showed more often high quality pictures than CT. CT and MRI demonstrated a good ...

2001-04-01

250

solQTL: a tool for QTL analysis, visualization and linking to genomes at SGN database  

UK PubMed Central (United Kingdom)

BackgroundA common approach to understanding the genetic basis of complex traits is through identification of associated quantitative trait loci (QTL). Fine mapping QTLs requires...Full Text Available

251

Use of DNA ladders for reproducible protein fractionation by SDS-PAGE for quantitative proteomics  

UK PubMed Central (United Kingdom)

In proteomics, one-dimensional (1D) SDS-PAGE is widely used for protein fractionation prior to mass spectrometric analysis to enhance dynamic range of analysis and to improve identification...Full Text Available

2008-02-01

252

Tissue distribution of brain-thymus shared antigens recognized by anti-brain xenosera in the rat, dog and man.  

UK PubMed Central (United Kingdom)

A comparative and quantitative study of the tissue distribution of brain-thymus shared antigens was carried out using rabbit antisera to rat, dog and human brain homogenates, assayed on rat, dog and...Full Text Available

1979-03-01

253

The inhibition of tumor cell intravasation and subsequent metastasis through the regulation of in vivo tumor cell motility by the tetraspanin CD151  

UK PubMed Central (United Kingdom)

SummaryIn vivo tumor cell migration through integrin-dependent pathways is key to the metastatic behavior of malignant cells. Using quantitative in vivo...Full Text Available

2008-03-01

254

Subventricular Zone Cell Migration: Lessons from Quantitative Two-Photon Microscopy  

UK PubMed Central (United Kingdom)

Neuroblasts born in the adult subventricular zone (SVZ) migrate long distances in the rostral migratory stream (RMS) to the olfactory bulbs where they integrate into circuitry as functional interneurons....Full Text Available

255

Study on the transient piping vibration of power plant. Secondary piping system of Wolsung 1 unit.  

Science.gov (United States)

In order to maintain a safe operation and availability of generating facilities, qualitative and quantitative assessment of piping vibration was performed vibration sources and damages of piping support was identified on the second piping system of Wolsun...

1996-01-01

256

Study of building materials impregnation processes by quasi-real-time neutron radiography  

International Nuclear Information System (INIS)

Neutron radiography (NR) is a useful non-destructive method for determination of hydrogen content in various building and technical materials. Monitoring of transport processes of moisture and hydrogenous liquids in porous building materials is enabled by fast, quasi-real-time NR methods based on novel imaging plate neutron detectors (IP-NDs). Hydrogen content in the samples is determined by quantitative analysis of measured profiles of neutron attenuation in the samples. Detailed description of quantitative NR method is presented by the authors in another accompanying contribution at this conference. Deterioration of building materials is originated by different processes that all require presence of water therefore it is essential to limit or prevent the transport of water through the porous material. In this presentation, results of a study of clay brick impregnation by silicone based hydrophobic agents will be presented. ...

1999-11-03

257

Structure of lipid bilayers  

UK PubMed Central (United Kingdom)

The quantitative experimental uncertainty in the structure of fully hydrated, biologically relevant, fluid (Lα) phase lipid bilayers has been too large to...Full Text Available

2000-11-10

258

Solid-Phase Radioimmunoassay of Total and Influenza-Specific Immunoglobulin G  

UK PubMed Central (United Kingdom)

An antigen-antibody system of polystyrene tubes coated with immunoglobulin antibody was used for quantitating immunoglobulins. A similar radioimmunoassay method was adapted for a viral antigen-antibody...Full Text Available

1972-02-01

259

Quantitative bone scintigraphy in children and adolescents. Age dependence of skeleton uptake  

International Nuclear Information System (INIS)

French ... Orig. Title Scintigraphie osseuse quantifiee chez l'enfant et l'adolescent - repartition selon l'age des taux de fixation de diverses pieces osseuses normales.

260

Quantitative bone scintigraphy and 24-hour whole-body counting of [sup 99m]Tc-methylene diphosphonate in patients with prostatic carcinoma  

Energy Technology Data Exchange (ETDEWEB)

Thirty-four patients with prostatic carcinoma were studied with quantitative bone scintigraphy and whole-body counting (WBC) 1 and 24 h after injection of [sup 99m]Tc-MDP before as well as two weeks and two months after orchiectomy. Thirteen of the patients had normal bone scintigrams and WBR at the three different investigations; 21 had skeletal metastases. The latter showed throughout the study higher local gamma camera count rates as well as WBR values than the patiens with normal scintigrams. In these patients a ''flare phenomenon'', with an increase in count rate two weeks after orchiectomy followed by a decrease two months post-operatively, was seen with quantitative bone scintigraphy but not with WBC. However, WBC may be a valuable method indicating the total extent of skeletal metastases in the body, while quantitative bone scintigraphy is more accurate in the interpretation of ...

1992-10-01

261

Quantitative bone scintigraphy and 24-hour whole-body counting of "9"9"mTc-methylene diphosphonate in patients with prostatic carcinoma  

International Nuclear Information System (INIS)

Thirty-four patients with prostatic carcinoma were studied with quantitative bone scintigraphy and whole-body counting (WBC) 1 and 24 h after injection of "9"9"mTc-MDP before as well as two weeks and two months after orchiectomy. Thirteen of the patients had normal bone scintigrams and WBR at the three different investigations; 21 had skeletal metastases. The latter showed throughout the study higher local gamma camera count rates as well as WBR values than the patiens with normal scintigrams. In these patients a ''flare phenomenon'', with an increase in count rate two weeks after orchiectomy followed by a decrease two months post-operatively, was seen with quantitative bone scintigraphy but not with WBC. However, WBC may be a valuable method indicating the total extent of skeletal metastases in the body, while quantitative bone scintigraphy is more accurate in the interpretation of individual skeletal metastases. (orig.).

262

Quantitative and Qualitative Usage Data of an Internet-Based Asthma Monitoring Tool  

UK PubMed Central (United Kingdom)

Background In May 2000, AstraZeneca launched a Web service for asthma patients and health-care providers called LinkMedica, which includes an asthma diary for...Full Text Available

263

Quantitative analysis of the disopyramide concentration-effect relationship.  

UK PubMed Central (United Kingdom)

1. A combined pharmacokinetic-pharmacodynamic model has been used to analyse the relationship between QT prolongation and changes in plasma concentration which occurred after disopyramide was given...Full Text Available

1980-01-01

264

Quantitative Skeletal Histology in Untreated End-stage Renal Failure  

UK PubMed Central (United Kingdom)

Forty-six patients with end-stage renal failure were subjected to iliac crest biopsy before the initiation of a dialysis programme and regardless of the presence of skeletal symptoms....Full Text Available

1973-06-30

265

Quantitative PCR Assay for Mycobacterium pseudoshottsii and Mycobacterium shottsii and Application to Environmental Samples and Fishes from the Chesapeake Bay?  

UK PubMed Central (United Kingdom)

Striped bass (Morone saxatilis) in the Chesapeake Bay are currently experiencing a very high prevalence of mycobacteriosis associated with newly described Mycobacterium...Full Text Available

2010-09-01

266

Quantitative Analysis of Endocytosis and Turnover of Epidermal Growth Factor (EGF) and EGF Receptor  

UK PubMed Central (United Kingdom)

Binding of epidermal growth factor (EGF) to the EGF receptor (EGFR) initiates signal transduction, ultimately leading to altered gene expression. Ligand-activated EGFR is also rapidly internalized...Full Text Available

2010-03-01

267

Qualitative and Quantitative Effects of Treatment for Dental Fear and Avoidance  

UK PubMed Central (United Kingdom)

In a Swedish community-based program for the treatment of dental phobic patients, a clinical trial was performed among 99 severely phobic individuals with long-standing avoidance of dental treatment....Full Text Available

1986-01-01

268

QTL detection by multi-parent linkage mapping in oil palm (Elaeis guineensis Jacq.)  

UK PubMed Central (United Kingdom)

A quantitative trait locus (QTL) analysis designed for a multi-parent population was carried out and tested in oil palm (Elaeis guineensis Jacq.), which is a diploid cross-fertilising...Full Text Available

2010-05-01

269

Probing the Mechanisms of an Air Amplifier using a LTQ-FT-ICR-MS and Fluorescence Spectroscopy  

UK PubMed Central (United Kingdom)

We report the first quantitative assessment of electrosprayed droplet/ion focusing enabled by the use of a voltage-assisted air amplifier between an electrospray ionization emitter and a hybrid...Full Text Available

2007-11-01

270

Precise temporal control of the eye regulatory gene Pax6 via enhancer-binding site affinity  

UK PubMed Central (United Kingdom)

How transcription factors interpret the cis-regulatory logic encoded within enhancers to mediate quantitative changes in spatiotemporally restricted expression patterns during animal...Full Text Available

2010-05-15

271

Practical Applications of the Bioinformatics Toolbox for Narrowing Quantitative Trait Loci  

UK PubMed Central (United Kingdom)

Dissecting the genes involved in complex traits can be confounded by multiple factors, including extensive epistatic interactions among genes, the involvement of epigenetic regulators, and the variable...Full Text Available

2008-12-01

272

Pion-induced fission  

Energy Technology Data Exchange (ETDEWEB)

The A(..pi../sup +/,/sup 3/He)B reaction near threshold is studied in a model where the pion is absorbed by an /sup 4/He constituent of the target nucleus. The predictions of this model using harmonic oscillator cluster wave functions agree semi-quantitatively with the experimental data on the inverse reaction.

1982-03-10

273

Physical Morphology and Quantitative Characterization of Chemical Changes of Weathered PVC/Pine Composites.  

Science.gov (United States)

This study investigated weathering effects on polyvinyl chloride (PVC) based wood plastic composites (WPC), with a focus on the color and structure that is attributed to the material composition. It is directed towards quantifying the main chemical modifi...

2009-01-01

274

Pattern formation and traveling waves in myxobacteria: Theory and modeling  

UK PubMed Central (United Kingdom)

Recent experiments have provided new quantitative measurements of the rippling phenomenon in fields of developing myxobacteria cells. These measurements have enabled us to develop a mathematical model...Full Text Available

2001-12-18

275

Palliative Care Physicians' Religious / World View and Attitude Towards Euthanasia: A Quantitative Study Among Flemish Palliative Care Physicians  

UK PubMed Central (United Kingdom)

Aims:To Study the religious and ideological views and practice of Palliative Care physician towards Euthanasia.Materials and Methods:An...Full Text Available

2009-01-01

276

Observations on computerized quantitative bone scintigraphy in renal osteodystrophy  

Energy Technology Data Exchange (ETDEWEB)

Skeletal radiotracer (sup(99m)Tc-HEDP) uptake was quantitated with and without the aid of a computer in 30 chronic dialysis patients with histologic evidence of renal osteodystrophy. Before scintigraphy, elevated soft-tissue activity due to the absence of renal radiotracer excretion was reduced by hemodialysis. The results were compared with those of a normal group and with the results of the biochemical and the bone morphometric studies of these patients. In all patients the radiotracer uptake was elevated, often markedly. In several patients with minimal histologic bone disease, however, soft-tissue activity could not be normalized by hemodialysis although its influence on the quantitative data could be further reduced (but not excluded) by computer evaluation of skeletal radiotracer uptake. Since the latter technique clearly distinguished the majority of the patients from the normals, it appears that computerized ...

1984-09-01

277

Observations on computerized quantitative bone scintigraphy in renal osteodystrophy  

International Nuclear Information System (INIS)

Skeletal radiotracer (sup(99m)Tc-HEDP) uptake was quantitated with and without the aid of a computer in 30 chronic dialysis patients with histologic evidence of renal osteodystrophy. Before scintigraphy, elevated soft-tissue activity due to the absence of renal radiotracer excretion was reduced by hemodialysis. The results were compared with those of a normal group and with the results of the biochemical and the bone morphometric studies of these patients. In all patients the radiotracer uptake was elevated, often markedly. In several patients with minimal histologic bone disease, however, soft-tissue activity could not be normalized by hemodialysis although its influence on the quantitative data could be further reduced (but not excluded) by computer evaluation of skeletal radiotracer uptake. Since the latter technique clearly distinguished the majority of the patients from the normals, it appears that computerized ...

278

Neutron data requirements for calculating transactinide isotope build-up in reactors  

International Nuclear Information System (INIS)

Based on a generalized theory of perturbations and on non-linear programming an approach to the quantitative determination of necessary accuracies for nuclear data is described. It is used to calculate transactinide isotope build-up in reactors.

1979-08-01

279

Mechanistic insights from a quantitative analysis of pollen tube guidance  

UK PubMed Central (United Kingdom)

BackgroundPlant biologists have long speculated about the mechanisms that guide pollen tubes to ovules. Although there is now evidence that ovules emit a diffusible attractant, little...Full Text Available

280

Measuring the efficacy of anti-malarial drugs in vivo: quantitative PCR measurement of parasite clearance  

UK PubMed Central (United Kingdom)

BackgroundArtemisinin-based combination therapy, currently considered the therapy of choice for uncomplicated Plasmodium falciparum malaria in endemic countries,...Full Text Available

281

Localization of gold in synovial membrane of rheumatoid arthritis treated with sodium aurothiomalate. Studies by electron microscope and electron probe x-ray microanalysis.  

UK PubMed Central (United Kingdom)

The localization of gold in the synovial membrane of rheumatoid arthritis patients treated with sodium aurothiomalate was examined and quantitative analysis of epon-embedded sections was carried out...Full Text Available

1977-06-01

282

Immunoradiometric measurement of the factor VIII procoagulant antigen.  

UK PubMed Central (United Kingdom)

A fluid-phase immunoradiometric assay has been developed which identifies an antigen on the Factor VIII (antihemophilic factor) procoagulant protein. This sensitive and quantitative assay is not influenced...Full Text Available

1978-11-01

283

Image-based modeling of tumor shrinkage in head and neck radiation therapy1  

UK PubMed Central (United Kingdom)

Purpose: Understanding the kinetics of tumor growth∕shrinkage represents a critical step in quantitative assessment of therapeutics and realization of adaptive radiation therapy....Full Text Available

2010-05-01

284

High-Throughput Screen for Poly-3-Hydroxybutyrate in Escherichia coli and Synechocystis sp. Strain PCC6803  

UK PubMed Central (United Kingdom)

A novel, quantitative method for detecting poly-3-hydroxybutyrate (PHB) amounts in viable cells was developed to allow for high-throughput screening of mutant libraries. The staining technique was demonstrated...Full Text Available

2006-05-01

285

Gravitropism: Interaction of Sensitivity Modulation and Effector Redistribution 1  

UK PubMed Central (United Kingdom)

Our increasing capabilities for quantitative hormone analysis and automated high resolution growth studies have allowed a reassessment of the classical Cholodny-Went hypothesis of gravitropism. According...Full Text Available

1991-01-01

286

Gene expression patterns in four brain areas associate with quantitative measure of estrous behavior in dairy cows  

UK PubMed Central (United Kingdom)

BackgroundThe decline noticed in several fertility traits of dairy cattle over the past few decades is of major concern. Understanding of the genomic factors underlying fertility,...Full Text Available

287

Functional pools of oxidative and glycolytic fibers in human muscle observed by 31P magnetic resonance spectroscopy during exercise.  

UK PubMed Central (United Kingdom)

Quantitative probing of heterogeneous regions in muscle is feasible with phosphorus-31 magnetic resonance spectroscopy because of the differentiation of metabolic patterns of glycolytic and oxidative...Full Text Available

1987-12-01

288

Free and Conjugated Indole-3-Acetic Acid in Developing Bean Seeds 1  

UK PubMed Central (United Kingdom)

The changes in conjugated indole-3-acetic acid (IAA) levels compared to the levels of free IAA have been analyzed during the development of bean (Phaseolus vulgaris L.) seed using quantitative...Full Text Available

1989-10-01

289

Evolution of Nitrogen Oxide(s) during In Vivo Nitrate Reductase Assay of Soybean Leaves  

UK PubMed Central (United Kingdom)

Studies were conducted to quantitate the evolution of nitrogen oxides (NO(x)) from soybean [Glycine max (L.) Merr.] leaves during in vivo nitrate reductase...Full Text Available

1981-12-01

290

Effect of pH and Temperature on Denitrification Gene Expression and Activity in Pseudomonas mandelii?  

UK PubMed Central (United Kingdom)

Pseudomonas mandelii liquid cultures were studied to determine the effect of pH and temperature on denitrification gene expression, which was quantified by quantitative reverse transcription-PCR....Full Text Available

2009-06-01

291

Determination of Salirasib (S-trans, trans-farnesylthiosalicylic acid) in human plasma using liquid chromatography-tandem mass spectrometry  

UK PubMed Central (United Kingdom)

A liquid chromatography/tandem mass spectrometric (LC/MS/MS) assay was developed for the quantitative determination of salirasib (S-trans, trans-farnesylthiosalicylic acid,...Full Text Available

2008-06-15

292

Delineation of the Middle Longitudinal Fascicle in Humans: A Quantitative, In Vivo, DT-MRI Study  

UK PubMed Central (United Kingdom)

Experimental and imaging studies in monkeys have outlined various long association fiber bundles within the temporoparietal region. In the present study the trajectory of the middle longitudinal fascicle...Full Text Available

2009-04-01

293

Cytoplasmic pH Regulation in Acer pseudoplatanus Cells  

UK PubMed Central (United Kingdom)

Qualitative and quantitative aspects of the mechanisms involved in the regulation of cytoplasmic pH during an acid-load have been studied in Acer pseudoplatanus cells. Two main processes,...Full Text Available

1986-11-01

294

Ct3d: tracking microglia motility in 3D using a novel cosegmentation approach  

UK PubMed Central (United Kingdom)

Motivation: Cell tracking is an important method to quantitatively analyze time-lapse microscopy data. While numerous methods and tools exist for tracking cells in 2D time-lapse images,...Full Text Available

2011-02-15

295

Comparison of Optical and SEM BSE Imaging Techniques for Quantifying Alpha-Beta Titanium Alloy Microstructures (Preprint).  

Science.gov (United States)

Quantitative metallography is often used to confirm the proper processing of aerospace metallic materials. A microstructural feature of great importance for titanium alloys processed in the alpha-beta phase field is the volume fraction of primary alpha. S...

2006-01-01

296

Bimodal MR-PET agent for quantitative pH imaging  

UK PubMed Central (United Kingdom)

Activatable or “smart” magnetic resonance contrast agents have relaxivities that depend on environmental factors such as pH or enzymatic activity, but the MR signal depends on...Full Text Available

2010-03-22

297

Bedload measurements, East Fork River, Wyoming  

UK PubMed Central (United Kingdom)

A bedload trap in the riverbed provided direct quantitative measurement of debris-transport rate in the East Fork River, Wyoming, a basin of 466 km2 drainage area. Traction load moves only...Full Text Available

1976-04-01

298

Bacterial Oxidation of Sulfide Minerals in Column Leaching Experiments at Suboptimal Temperatures  

UK PubMed Central (United Kingdom)

The purpose of the work was to quantitatively characterize temperature effects on the bacterial leaching of sulfide ore material containing several sulfide minerals. The leaching was tested at eight...Full Text Available

1992-02-01

299

Augmenting Clinical Evaluation of Hemiparetic Arm Movement With a Laboratory-Based Quantitative Measurement of Kinematics as a Function of Limb Loading  

UK PubMed Central (United Kingdom)

BackgroundKinematic and kinetic measurements used in laboratory settings can quantify upper extremity movement impairment following stroke, but their relationship...Full Text Available

2008-01-01

300

Arabidopsis thaliana auxotrophs reveal a tryptophan-independent biosynthetic pathway for indole-3-acetic acid.  

UK PubMed Central (United Kingdom)

We used tryptophan auxotrophs of the dicot Arabidopsis thaliana (wall cress) to determine whether tryptophan has the capacity to serve as a precursor to the auxin, indole-3-acetic acid (IAA). Quantitative...Full Text Available

1993-11-01

301

Application of alpha and gamma spectroscopy to the quantitative analysis of transuranium nuclides in nuclear fuel  

Energy Technology Data Exchange (ETDEWEB)

In nuclear fuel with a burn-up of 33 kg/t U and 52 kg/t U 15 transuranium nuclides /sup 237/Np to /sup 246/Cm have been determined by alpha and gamma spectroscopy after radiochemical separation.

1984-11-01

302

Analysis of trigeminal nerve disorders after oral and maxillofacial intervention  

UK PubMed Central (United Kingdom)

BackgroundQuantitative sensory testing (QST) is applied to evaluate somatosensory nerve fiber function in the spinal system. This study uses QST in patients with sensory dysfunctions...Full Text Available

303

Analysis of Quantitative Interactions between Two Species of Arbuscular Mycorrhizal Fungi, Glomus mosseae and G. intraradices, by Real-Time PCR  

UK PubMed Central (United Kingdom)

Arbuscular mycorrhizal fungi (AMF) are obligate biotrophs, known to play an important role in ecological processes. Conventional light microscopy is the most common method used to detect their presence...Full Text Available

2006-06-01

304

An ounce of prevention or a pound of cure: bioeconomic risk analysis of invasive species.  

UK PubMed Central (United Kingdom)

Numbers of non-indigenous species--species introduced from elsewhere - are increasing rapidly worldwide, causing both environmental and economic damage. Rigorous quantitative risk-analysis frameworks,...Full Text Available

2002-12-07

305

Advances in metallography. Fortschritte in der Metallographie  

Energy Technology Data Exchange (ETDEWEB)

The 52 papers discuss the following subjects: 1. Preparation and structural development; 2. Structural constitution; 3. Structural formation and phase transition; 4. Structure and mechanical properties; 5. Structural formation of metallic and nonmetallic materials; 6. Quantitative metallography, and 7. Quality assurance.

1983-01-01

306

A double antibody solid phase assay for DNA autoantibodies for clinical use.  

UK PubMed Central (United Kingdom)

DNA antoantibodies in serum will bind to antigen-coated polystyrene tubes and can be detected by radiolabelled anti-immunoglobulin. The method is quantitative, gives information on the antibody class...Full Text Available

1976-08-01

307

A Rapid Murine Coma and Behavior Scale for Quantitative Assessment of Murine Cerebral Malaria  

UK PubMed Central (United Kingdom)

BackgroundCerebral malaria (CM) is a neurological syndrome that includes coma and seizures following malaria parasite infection. The pathophysiology is not fully understood and cannot...Full Text Available

308

Theoretical approach on microscopic bases of stochastic functional self-organization: quantitative measures of the organizational degree of the environment  

International Nuclear Information System (INIS)

There has been increased theoretical and experimental research interest in autonomous mobile robots exhibiting cooperative behaviour. This paper provides consistent quantitative measures of organizational degree of a two-dimensional environment. We proved, by the way of numerical simulations, that the theoretically derived values of the feature are reliable measures of aggregation degree. The slope of the feature's dependence on memory radius leads to an optimization criterion for stochastic functional self-organization. We also described the intellectual heritages that have guided our research, as well as possible future developments. (author)

2001-11-30

309

Quantitative density measurements from a real-time neutron radiography system  

Energy Technology Data Exchange (ETDEWEB)

An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.

1986-01-01

310

Quantitative density measurements from a real-time neutron radiography system  

International Nuclear Information System (INIS)

An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.

1986-11-16

311

Quantitative bone scintigraphy in the evaluation of angular deformity of the lower extremity  

International Nuclear Information System (INIS)

A technique for quantitative analysis of growth plates in varus or valgus deformity about the knee has been developed. Computer-generated regions of interest are placed on magnification scintigraphs to divide distal femoral and proximal tibial physes into four equal segments. The ratio of counts in the medial half to counts in the lateral half was studied in 31 children (22 normal, 9 with angular deformity). Normal ratios were 0.74 to 0.98 for femora and 0.98 to 1.20 for tibias. In eight of nine patients with deformity, the ratio was abnormal; in two patients the ratio returned to normal when the deformity ceased to progress.

312

Quantitative analysis of iodine in thyroidin. II. Method of combustion in flask with oxygen  

Energy Technology Data Exchange (ETDEWEB)

The authors experimentally study the separate stages of the determination of iodine in thyroidin by the combustion method in a flask with oxygen. The monotypic, conventional procedures and the procedure of Kolii and Pakhomov were studied. With addition of potassium iodide, a sixfold amount (compared with the initial) of iodine is liberated. Further, the liberated iodine is titrated by sodium thiosulfate. The authors find the degree of influence of a high nitrogen content on the determination of iodine in organic compounds. The procedure developed for the quantitative determination of the iodine in thyroidin by the combustion method is simple, fairly rapid, and can be used for the reliable control of the quality of thyroidin preparations and its starting raw material.

1986-11-01

313

Prediction of the compressive strength of vertebral bodies of the lumbar spine by quantitative computed tomography.  

Science.gov (United States)

The ultimate compressive strength of 36 thoracolumbar vertebrae was determined experimentally. In addition, the trabecular bone mineral content was measured by single energy quantitative computed tomography. The areas of fractured endplates were also determined by computed tomography. The results show that a linear relationship exists between the compressive strength and the product of bone density and endplate area. These data allow an in vivo prediction of vertebral body strength using a noninvasive method with a standard error of estimate amounting to less than 0.95 kN. PMID:3212488

1988-01-01

314

Mass fragmentographic determination of polymethylnaphthalene and polymethylphenanthrene in a crude oil and in marine organisms  

Energy Technology Data Exchange (ETDEWEB)

The investigation of the petroleum contamination in marine organisms requires the trace level quantitative determination of indicative substances to be identified by a fingerprint of petroleum. Polymethylnaphthalene (PMN) and polymethylphenanthrene (PMP) were chosen because of their simple separation from a crude oil by means of an activated charcoal chromatography, their relatively high existence in aromatic compounds, and their persistence relative to other petroleum components in the tissue of oil contaminated marine organisms. The purpose of this paper is to present an activated charcoal chromatographic separation procedure of PMN and PMP in a crude oil and a trace level quantitative analytical method of them in marine organisms by mass fragmentography (MF).

1980-09-01

315

Fuzzy performance measurement of a supply chain in manufacturing companies  

British Library Electronic Table of Contents (United Kingdom)

This paper is aimed to present a fuzzy decision making approach to deal with the performance measurement in supply chain systems. In the manufacturing environment, performance measurement is based on different quantitative and qualitative factors. Some of these factors may have a larger effect on the performance measure than others. Units of measure of the quantitative factors are different such as time, money, percentage, ratio, and counts. Thus, this paper presents a performance measurement approach based on fuzzy set theory and the pair-wise comparison of Analytical Hierarchy Process (AHP), which ensures the consistency of the designer's assignments of importance of one factor over another to find the weight of each of the manufacturing activity in the departmental organization. In the ...

2011-01-01

316

Effects of carbocalcitonin treatment on PAGET's disease assessed by quantitative bone scintigraphy  

International Nuclear Information System (INIS)

Sixteen patients with PAGET's disease of bone underwent quantitative bone scintigraphy with "9"9"mTc-MDP before and after a long-term treatment with carbocalcitonin, a synthetic analogue of eel calcitonin. The radionuclide study consisted in the blood pool and bone uptake measurement and in the bone avidity calculation (bone uptake - blood pool ratio). In our patients, a significant decrease in bone uptake and bone avidity was found, whereas the blood pool remained statistically unchanged. This behaviour could be accounted for the shift of the compact bone to a lamellar pattern. (orig.).

317

Effects of carbocalcitonin treatment on PAGET's disease assessed by quantitative bone scintigraphy  

Energy Technology Data Exchange (ETDEWEB)

Sixteen patients with PAGET's disease of bone underwent quantitative bone scintigraphy with /sup 99m/Tc-MDP before and after a long-term treatment with carbocalcitonin, a synthetic analogue of eel calcitonin. The radionuclide study consisted in the blood pool and bone uptake measurement and in the bone avidity calculation (bone uptake - blood pool ratio). In our patients, a significant decrease in bone uptake and bone avidity was found, whereas the blood pool remained statistically unchanged. This behaviour could be accounted for the shift of the compact bone to a lamellar pattern.

1988-06-01

318

Development of safety function assessment trees for pressurized heavy water reactor LP/SD operations  

Energy Technology Data Exchange (ETDEWEB)

The objective of Configuration Risk Management Program(CRMP) is to maintain the safety level by assuring the defense-in-depth of nuclear power plant while the configurations are changed during plant operations, especially for the LP/SD. Such a safety purpose can be achieved by establishing the risk monitoring programs with both quantitative and qualitative features. Generally, the quantitative risk evaluation models, i.e., PRA models are used for the risk evaluation during full power operation, and the qualitative risk evaluation models such as safety function assessment trees are used. Through this study, safety function assessment trees were developed.

2003-10-01

319

[Natriuretic peptides--relevance in intensive care].  

Science.gov (United States)

The family of natriuretic peptides consists of the atria natriuretic peptide (ANP), the cerebral natriuretic peptide (BNP), the type C natriuretic peptide (CNP) and the peptide isolated from the dendroaspis snakes' poison (DNP), whose presence in humans has not been confirmed. The physiological function of ANP is in the control of arterial blood pressure by regulation of systemic vascular resistance of blood vessels. BNP is produced as one of the factors in the acute response to inflammatory tissue damage, mainly in coronary vessels. Increased serum concentrations of natriuretic peptides have been found in stress situations, such as trauma or major surgery, systemic hypotension, and in intrinsic myocardial dysfunction. High concentrations of natriuretic peptides were observed in severe sepsis, septic shock and in multiple organ failure, probably due to increased secretion by mediators of the inflammatory process.The highest concentrations of ANP and BNP were found ...

320

Utilization of Tc-99m-TBI as a myocardial perfusion agent in exercise studies: Comparison with Tl-201 thallous chloride and examination of its biodistribution in humans  

Energy Technology Data Exchange (ETDEWEB)

Twenty-four patients were studied with both /sup 201/Tl-thallus chloride and /sup 99m/Tc-TBI scintigraphy following exercise. Comparison of the two agents in detecting segmental myocardial ischemia and scar was made in 18 patients with evidence of coronary artery disease on /sup 201/Tl-thallous chloride scintigraphy. Agreement between the two studies was observed in 77% (125 of 162) of left ventricular segments, suggesting that /sup 99m/Tc-TBI can be used as a myocardial perfusion agent. Limitations were related to early high background activity from lungs and liver. The high lung activity and early myocardial redistribution within the 1st hour contributed to the failure of /sup 99m/Tc-TBI to detect 16 segmental defects seen in the immediate post-exercise thallous chloride scan. Persistently high liver activity additionally affected accurate interpretation in the left ventricular segments close to the diaphragm. Improvement in the accuracy of /sup 99m/Tc-TBI stress ...

1986-10-01

321

Routine upfront abciximab versus standard periprocedural therapy in patients undergoing primary percutaneous coronary intervention for cardiogenic shock: The PRAGUE-7 Study. An open randomized multicentre study  

British Library Electronic Table of Contents (United Kingdom)

Background: The outcome of acute myocardial infarction (AMI) complicated with cardiogenic shock is poor. The aim of this study was to analyse, whether upfront abciximab administration could improve the outcomes of cardiogenic shock. Methods: This multicentre open trial randomized 80 patients with AMI complicated by cardiogenic shock expected to undergo primary PCI into group A (routine upfront-pre-procedural-abciximab bolus followed by 12-h abciximab infusion) and group B (standard therapy). The study primary objective was 30-day combined outcome (death/reinfarction/stroke/new severe renal failure). Results: PCI was technically successful in 90% (A) versus 87.5% (B) patients. Abciximab was used in 100% (A) versus 35% (B). The primary endpoint occurred in 17 group A patients (42.5%) and 11 ...

2011-01-01

322

Myocardial perfusion SPECT in patients after myocardial infarction: Comparison of "2"0"1Tl and dual-isotope protocol (rest "2"0"1Tl/stress "9"9"mTc tetrofosmin)  

International Nuclear Information System (INIS)

The diagnostic accuracy is compared of the dual-isotope protocol and the conventional "2"0"1Tl protocol, for detection of the coronary artery disease (CAD) using data on a total of 69 patients after myocardial infarction (MI). The "2"0"1Tl protocol was used to examine 44 patients, the dual-isotope protocol was used with 25 patients. All patients were examined by coronarography; a narrowing of the artery by more than 50 % was considered significant for CAD. The sensitivity, specificity and diagnostic accuracy was 97.7 %, 100 % and 97.7 % resp. for the "2"0"1Tl protocol, and 95.2 %, 75 % and 92 % resp. for the dual-isotope protocol. A higher diagnostic accuracy of the dual-isotope protocol has not been proven, and the "2"0"1Tl protocol continues to be used for examinations of patients after MI

1998-08-01

323

Intracardiac Echocardiography: A New Guiding Tool for Transcatheter Aortic Valve Replacement  

British Library Electronic Table of Contents (United Kingdom)

BackgroundEchocardiography has been debated as an adjunct for transcatheter aortic valve replacement (TAVR). The aim of this prospective study was to comparatively evaluate intraprocedural guidance using intracardiac echocardiography (ICE) and transesophageal echocardiography (TEE). MethodsFifty high-risk patients with severe aortic stenosis scheduled for TAVR were randomized to either guidance using ICE (group 1; n = 25) or monitoring using TEE (group 2; n = 25). ResultsIn contrast to TEE, ICE allowed continuous monitoring. The need for probe repositioning during the procedure was much lower in group 1 (0.1 +- 0.3 vs 5.7 +- 0.7 maneuvers, P P = .003). Both coronary ostia were more frequently visualized in group 1 (18 vs 2 cases, P n = 25, r2 = 0.90, P n = 11, P = .012), but ICE did not (m...

2011-01-01

324

Influence of manufacturing methods on the homogeneity and properties of nitinol tubular stents  

Energy Technology Data Exchange (ETDEWEB)

Nitinol has found growing applications in vascular stents, with the recent introduction on the market of a number of new nitinol tubular devices for coronary and peripheral usage. These stents can be produced either through the expansion of a pattern cut on a small tube (pre-cut) or by cutting the deployed design on a tube of a larger size (pre-expanded). The aim of the study was to analyze the differences of properties induced by the two manufacturing methods. For this purpose, differential scanning calorimetry (DSC) measurements were performed on various specimens from the two types of stents. A first set of measurements shows that pre-expanded stents exhibit usual A<->R<->M transformations whereas multi-stage transformations occur for pre-cut stents. Two types of DSC specimens were then prepared for each stent, corresponding to the straight sections and the curved parts of the stent. It is shown that the pre-cut stents exhibit less ...

2001-11-01

325

Epidemiologic studies of coronary heart disease and stroke in Japanese men living in Japan, Hawaii, and California: demographic, physical, dietary, and biochemical characteristics  

International Nuclear Information System (INIS)

These summary descriptive data of ethnically similar cohorts of indigenous and migrant Japanese males have shown similarities or slight differences in characteristics wholly or largely genetically determined, such as blood groups, stature, and skeletal size. Differences have been noted in characteristics largely environmental or behavioral, such as diet and cigarette smoking habit, as well as in characteristics determined by a varying mixture of genetic and environmental influences, such as weight, blood pressure, glucose tolerance, and serum lipid and uric acid levels. Detailed analyses of the distributions of laboratory variables, of dietary data obtained by different methods, and of correlations among laboratory, dietary, physical, and demographic variables are currently in progress. Also part of the study plan are determinations of disease prevalence from evaluation of examination, laboratory, and electrocardiographic findings, of disease incidence from repeat examinations and from ...

326

The design of hazard risk assessment matrices for ranking occupational health risks and their application in mining and minerals processing.  

Science.gov (United States)

Two hazard risk assessment matrices for the ranking of occupational health risks are described. The qualitative matrix uses qualitative measures of probability and consequence to determine risk assessment codes for hazard-disease combinations. A walk-through survey of an underground metalliferous mine and concentrator is used to demonstrate how the qualitative matrix can be applied to determine priorities for the control of occupational health hazards. The semi-quantitative matrix uses attributable risk as a quantitative measure of probability and uses qualitative measures of consequence. A practical application of this matrix is the determination of occupational health priorities using existing epidemiological studies. Calculated attributable risks from epidemiological studies of hazard-disease combinations in mining and minerals processing are used as examples. These historic response data do not reflect the risks associated with current ...

2001-03-01

327

Quantitative bone scintigraphy in patients with osteoporosis  

International Nuclear Information System (INIS)

Quantitative bone scans were evaluated in 16 patients with osteoporosis and in a control group of 7 healthy subjects. Along with a detailed biochemical analysis of calcium-phosphorus metabolism and standartized reongenographs, a quantitative dynamic bone scintigraphy was performed according to the method proposed by the authors. The bone-accumulating factor K_b was determined on the base of mathematical analysis of the graph reflecting activity changes in bone tissue unit during the investigation, the blood-elimination factor K_h and kidney-elimination factor K_k. In addition the accumulation index AI (in %) was calculated as a relation between the activity in bone tissue unit, registered in 20 min interval, and the activity in soft tissues for the same time. Whereas the static gamma camera scintigraphy, made 3-4 hrs after injecting of the osteotrope radiopharmaceuticals, showed no specific changes in the patients examined, the method proposed ...

328

Quantitative bone scintigraphy in evaluating treatment of renal osteodystrophy  

Energy Technology Data Exchange (ETDEWEB)

The effect of various forms of treatment of renal osteodystrophy was evaluated in 25 dialysis patients by quantitative bone scintigraphy, using 99m-Tc-HEDP. The results were compared with those of biochemical and bone morphometric studies. The total skeletal activity (TSA) decreased in 5 patients after transplantation, in 11 after parathyroidectomy and in 6 out of 9 treated conservatively, but did not normalize in any of the patients. Bone morphometric evaluation of treatment, which could be performed in 19 of the 20 patients who did not receive a transplant, demonstrated a reduction in the degree of hyperparathyroidism in 17 patients (89 percent). Osteoid excess was reduced in 13 patients (68 percent) but an evident reduction of osteomalacic osteoid, i.e. improvement of osteomalacia, occurred in only 4 patients (21 percent). Changes in the TSA correlated significantly with the changes in the biochemical and histological parameters of hyperparathyroidism, but not ...

1983-01-01

329

Quantitative bone scintigraphy in evaluating treatment of renal osteodystrophy  

International Nuclear Information System (INIS)

The effect of various forms of treatment of renal osteodystrophy was evaluated in 25 dialysis patients by quantitative bone scintigraphy, using 99m-Tc-HEDP. The results were compared with those of biochemical and bone morphometric studies. The total skeletal activity (TSA) decreased in 5 patients after transplantation, in 11 after parathyroidectomy and in 6 out of 9 treated conservatively, but did not normalize in any of the patients. Bone morphometric evaluation of treatment, which could be performed in 19 of the 20 patients who did not receive a transplant, demonstrated a reduction in the degree of hyperparathyroidism in 17 patients (89 per cent). Osteoid excess was reduced in 13 patients (68 per cent) but an evident reduction of osteomalacic osteoid, i.e. improvement of osteomalacia, occurred in only 4 patients (21 per cent). Changes in the TSA correlated significantly with the changes in the biochemical and histological parameters of hyperparathyroidism, but ...

330

New insight on the interaction and diffusion properties of ion beam injected self-interstitials in crystalline silicon  

Energy Technology Data Exchange (ETDEWEB)

The diffusion of ion beam injected self-interstitials (I) and their interaction with impurities in crystalline Si has been investigated and modeled. In particular, the I-substitutional carbon (C) interactions have been studied, using a molecular-beam-epitaxy grown Si{sub 1-y}C{sub y} layer interposed between the shallow I-source and a deeper B-spike (marker for I-concentration). Substitutional C atoms are shown to trap I's, to be removed from their substitutional sites, and to form stable precipitates into the C-rich region. The I-trapping mechanism was quantitatively studied by a simulation code. The reactions causing trapping and deactivation are described. In addition, the boron markers approach was extended to the two dimensional (2D) diffusion. High resolution scanning capacitance microscopy was used for quantitative measurements of the 2D boron transient enhanced diffusion induced on a boron delta array by the I's ion ...

2003-05-01

331

New insight on the interaction and diffusion properties of ion beam injected self-interstitials in crystalline silicon  

International Nuclear Information System (INIS)

The diffusion of ion beam injected self-interstitials (I) and their interaction with impurities in crystalline Si has been investigated and modeled. In particular, the I-substitutional carbon (C) interactions have been studied, using a molecular-beam-epitaxy grown Si_1_-_yC_y layer interposed between the shallow I-source and a deeper B-spike (marker for I-concentration). Substitutional C atoms are shown to trap I's, to be removed from their substitutional sites, and to form stable precipitates into the C-rich region. The I-trapping mechanism was quantitatively studied by a simulation code. The reactions causing trapping and deactivation are described. In addition, the boron markers approach was extended to the two dimensional (2D) diffusion. High resolution scanning capacitance microscopy was used for quantitative measurements of the 2D boron transient enhanced diffusion induced on a boron delta array by the I's ion beam injected through a ...

2003-05-01

332

New facility design and work method for the quantitative fit testing laboratory. Master's thesis  

Energy Technology Data Exchange (ETDEWEB)

The United States Air Force School of Aerospace Medicine (USAFSAM) tests the quantitative fit of masks which are worn by military personnel during nuclear, biological, and chemical warfare. Subjects are placed in a Dynatech-Frontier Fit Testing Chamber, salt air is fed into the chamber, and samples of air are drawn from the mask and the chamber. The ratio of salt air outside the mask to salt air inside the mask is called the quantitative fit factor. A motion-time study was conducted to evaluate the efficiency of the layout and work method presently used in the laboratory. A link analysis was done to determine equipment priorities, and the link data and design guidelines were used to develop three proposed laboratory designs. The proposals were evaluated by projecting the time and motion efficiency, and the energy expended working in each design. Also evaluated were the lengths of the equipment links for each proposal, and each ...

1989-05-01

333

Diagnostic capabilities of quantitative bone scintigraphy in ankylosing spondylitis: A comparison with radiography  

International Nuclear Information System (INIS)

In 576 patients quantitative scintigraphy of the sacroiliac joints and the spinal cord with "9"9"mTc-pyrophosphate was performed. 328 were patients with proven ankylosing spondylitis according to the New York criteria. 120 were patients with a clinically and roentgenologically suspected ankylosing spondylitis and 128 persons formed a healthy control group. The count rate in small regions of interest (ROI) in the sacroiliac joints, the spinal cord and the os sacrum were compared on the basis of indexes. The scintigraphic data of patients with ankylosing spondylitis were compared with the healthy control group and with the radiographic findings and radiologic staging of the disease. In a longitudinal follow-up study during 1 to 6 years these investigations were continued together with clinical and roentgenological checks. Quantitative bone scintigraphy provides characteristic indexes for ankylosing spondylitis, indicating the increased mineral ...

334

Comparative evaluation of the quantitative bone scintigraphy and the radiography in patients with ankylosing spondylitis  

International Nuclear Information System (INIS)

In 620 patients quantitative bone scintigraphy with "9"9"mTc pyrophosphate of the sacroiliac joints and of the spine was performed: 365 patients with confirmed ankylosing spondylitis, 125 patients with clinical radiological suspicion for ankylosing spondylitis (probable Bechterev) and control group of 130 healthy individuals. By comparison of the activity in zones of interest of the sacroiliac joints, the spine and sacrum, the following indices were determined: sacroiliac (separately for the left and right sacroiliac joints), index D_1_0/sacrum, index L_4/sacrum and index C_7/sacrum. The scintigraphic finding was compared to the X-ray one and to the radiological stage of the disease. A long-term follow-up of the patients was carried out during 1-6 years with scintigraphic, X-ray and clinical investigations. Emphasis was laid upon the posibilities for quantitative scintigraphy for early diagnostics of ankylosing spondylitis. The combination of ...

335

Assessment of liver circulation by quantitative scintiangiography: Evaluation of the relative contribution of the hepatic arterial and portal venous blood flows to liver perfusion  

Energy Technology Data Exchange (ETDEWEB)

Quantitative hepatic scintiangiography was previously used for evaluating the relative contribution of hepatic arterial and portal venous blood flows to the hepatic circulation. The present study compares 3 different procedures (automatic and manual integration, and slope fitting methods) for analyzing the hepatic time activity curves obtained after bolus i.v. injection of 370 MBq /sup 99m/Tc-diethylentriaminopentacetic acid. Twenty five subjects were studied: Five controls, ten cirrhotics, and ten portal hypertensive patients previously submitted to side to side portacaval anastomosis. The correspondence between results given by the different methods was satisfactory only in shunted patients, and the reproducibility of computed parameters was quite poor for all procedures. Accordingly, none of the methods can be considered as supporting reliable quantitative pathophysiological evaluations. However, the hepatic arterial/portal venous flow ratio ...

1989-04-01

336

Vascular complications following 1500 consecutive living and cadaveric donor renal transplantations: A single center study  

International Nuclear Information System (INIS)

The aim of this study was to document vascular complications that occurred following cadaveric and living donor kidney transplants in order to assess the overall incidence of these complications at our center as well as to identify possible risk factors. In a retrospective cohort study, 1500 consecutive renal transplant recipients who received a living or cadaveric donor kidney between December 1988 and July 2006 were evaluated. The study was performed at the Nemazee Hospital, Shiraz, Iran. The assessment of the anatomy and number of renal arteries as well as the incidence of vascular complications was made by color doppler ultrasonography, angiography, and/or surgical exploration. Clinically apparent vascular complications were seen in 8.86% of all study patients (n = 133) with the most frequent being hemorrhage (n = 91; 6.1%) followed by allograft renal artery stenosis (n = 26; 1.7%), renal artery thrombosis (n = 9; 0.6%), and renal vein thrombosis (n = 7; 0.5%). ...

337

Unsolved problems in the diagnosis and surgical treatment of intramedullary tumors  

Energy Technology Data Exchange (ETDEWEB)

Problems and solutions in the diagnosis and operative treatment were clarified by retrospective evaluation of cases of intramedullary tumor in which MRI and surgery had been performed. The subjects were 16 patients (21-75 years old, mean age: 45 years) whose tumor was surgically removed between 1991 and 1998. MRI was performed preoperatively, and T1-weighted images, T2-weighted images, and enhanced images were obtained. Angiography was also performed in some cases. The histological diagnosis based on the MRI findings before surgery were compared with the pathological diagnosis after the operation. In 9/16 cases (56%), the preoperative histological diagnosis based on the MR images was the same as the pathological diagnosis after the operation. In 8 of the 11 cases (73%) whose images showed clear tumor margins and well shaped the tumor, the tumors were completely removed. The concordance rate between the pathological diagnosis during and after the operation was 67%. ...

2001-04-01

338

The Primary Patency and Fracture Rates of Self-Expandable Nitinol Stents Placed in the Popliteal Arteries, Especially in the P2 and P3 Segments, in Korean Patients  

Energy Technology Data Exchange (ETDEWEB)

We wanted to evaluate the status of self-expandable nitinol stents implanted in the P2 and P3 segments of the popliteal artery in Korean patients. We retrospectively analyzed 189 consecutive patients who underwent endovascular treatment for steno occlusive lesions in the femoropopliteal artery from July 2003 to March 2009, and 18 patients who underwent stent placement in popliteal arterial P2 and P3 segments were finally enrolled. Lesion patency was evaluated by ultrasound or CT angiography, and stent fracture was assessed by plain X-rays at 1, 3, 6 and 12 months and annually thereafter. At the 1-month follow-up, stent fracture (Type 2) was seen in one limb (up to P3, 1 of 18, 6%) and it was identified in seven limbs at the 3-month follow-up (Type 2, Type 3, Type 4) (n = 1: up to P2: n = 6: P3). At the 6-month follow-up, one more fracture (Type 1) (up to P3) was noted. At the 1-year follow-up, there were no additional stent fractures. Just four limbs (up to P2) at ...

2011-04-15

339

Patterns of vascular invasion of intrahepatic peripheral cholangiocarcinoma examined with angiography and angiographic CT  

International Nuclear Information System (INIS)

To evaluate the radiological patterns of vascular invasion in peripheral cholangiocarcinomas. Hepatic arteriography and portography in 20 cases with cholangiocarcinoma including 12 cases with angiographic CT were retrospectively analyzed. The arteriography showed no arterioportal shunt, hypertrophy of tumor vessel, or tumor staining extending to central portion of the mass in all cases. However, doughnut shaped peripheral tumor staining was seen until late hepatogram phase in 12 cases and compensatory hyperperfusion around the mass was seen in six cases (eight cases if include arterial CT). Encasement of tumor vessel was seen in 12 cases, and hypertrophy of feeding vessel in nine cases. On portography, the filling defect on segmental portal branch could be demonstrated only in 11 cases. Shape of the portal defect was tapered narrowing in six cases, abrupt narrowing in two cases but intraluminal nodular filling defect was not seen. Remaining three cases were difficult to define the ...

1995-01-01

340

Multidetector-row helical CT: analysis of time management and workflow  

International Nuclear Information System (INIS)

The purpose of this study was to evaluate time management and workflow for multidetector-row helical CT (MDCT). Time for patient and data handling of at total of 580 patients were evaluated at two different time periods (December 1999, August 2000), each for the following baseline measurements: (a) change of clothes/instruction; (b) patient placement on the CT table/i.v. catheter; (c) CT planning and programming; (d) CT data acquisition; (e) CT data reconstruction; (f) CT data storage/printing. All imaging was performed on a Somatom Volume Zoom (Siemens, Erlangen, Germany). Time measurements summarized for different CT protocols revealed the following: (a) 5:01 min (#+-#2.06 min); (b) 4:36 min (#+-#2.43 min); (c) 4:11 min (#+-#2.55 min); (d) 0:43 min (#+-#0.15 min); (e) 6:59 min (#+-#2.39 min); (f) 09:51 min (#+-#3.51 min). Planning and programming was most time-consuming for CT angiography, whereas chest and abdominal CT needed only 3:26 and 3:30 min, ...

2002-03-01

341

Lung perfusion scintigraphy in the diagnosis of peripheral pulmonary stenosis in patients after repair of Fallot tetralogy  

International Nuclear Information System (INIS)

The frequency of peripheral pulmonary artery stenosis in patients after surgical repair of tetralogy of Fallot (TOF) ranges from 20 to 40%. This can be either primary or secondary to the surgical intervention. The influence of resulting lung perfusion alterations on the life quality of patients is difficult to predict. The aim of this study was to compare the utility of the diagnostic procedures in this group of patients, with particular focus on lung perfusion scintigraphy. This study comprised 104 patients who underwent repair of TOF at ages from 5 months to 25 years. The patients have been followed up for from 4.2 to 25 years. On the basis of chest X-ray peripheral pulmonary artery stenosis was suspected in 11 patients, in 12 on the basis of echocardiography examination. Lung perfusion scintigraphy has been performed on 87 patients. The disturbances in lung perfusion (mostly in the left lung) were show by means of lung perfusion scintigraphy in 43 (49%) of patients. In 27 of them ...

342

Hemodynamic characteristics of early stage hepatocellular carcinoma; In vivo evaluation with vascular imagings  

Energy Technology Data Exchange (ETDEWEB)

Hemodynamic characteristics were studied by using in vivo vascular imaging techniques in 17 resected early stage hepatocellular carcinoma (e-HCC) by comparing them with 49 resected advanced HCCs (ad-HCC) less than 3 cm in diameter. In this study, e-HCC was defined as the nodule being uniformly composed of well-differentiated HCC or adenomatous hyperplastic nodule containing well-differentiated HCC foci within the nodule. In vivo vascular imaging techniques are as follows; US angiography with intraarterial CO{sub 2} microbubbles were performed to assess the tumor arterial vascularity, and CT during arterial portography (CTAP) was performed to assess the portal perfusion within the nodule. Of 17 e-HCC nodules 5 were hypervascular, 5 were isovascular, 4 were hypovascular, and 3 were vascular spot in hypovascular pattern in contrast to 49 ad-HCC nodules, 43 of which were hypervascular and 6 were isovascular. Of 14 e-HCCs, 9 nodules showed perfusion defect and 5 did not ...

1992-04-01

343

CF findings of bowel infarction in 56 surgical patients, 5 of whom with reversible ischemia; Aspetti alla tomografia computerizzata dell'infarto intestinale. 56 pazienti sottoposti a interventi chirurgico di cui 5 con ischemia mesenterica reversibile.  

Energy Technology Data Exchange (ETDEWEB)

Bowel infarction is a rare and typical condition of the elderly; despite improvements in diagnostic imaging and vascular surgery, bowel infarction remains a major cause of acute abdomen, with mortality rates ranging 70-80%. Diagnosis on often late because clinical signs, laboratory data and radiologic findings are a specific. The authors investigated radiographic and particular CT patterns of intestinal infraction in 56 patients submitted to surgery within 12 hours of admission. We also report the CT findings of 5 of these patients who had reversible mesenteric ischemia. CT is more sensitive than radiography and does not exhibit the limitations of angiography (i.e., invasiveness, radiation exposure and complex organization). Therefore CT can presently be considered the method of choice in patients with suspected bowel infarction. [Italian] L'infarto intestinale rappresenta una malattia rara e tipica del soggeto anziano; nonostante il notevole ...

1999-04-01

344

X-ray Phase Imaging Microscopy using a Fresnel Zone Plate and a Transmission Grating  

International Nuclear Information System (INIS)

We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.

2010-06-23

345

Synthesis of novel tellurium containing analogues of choline and acetylcholine and their quantitation by pyrolysis-gas chromatography-mass spectrometry.  

Science.gov (United States)

Methods for the synthesis and quantitation of the novel choline analogues, telluronium choline and acetyltelluronium choline, are described. An assay procedure utilizing pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS) with cold trapping was developed with [2H4]telluronium choline and [2H4]acetyltelluronium choline as internal standards. The telluronium compounds were ion-pair extracted from tissue with dipicrylamine, washed with 2-butanone, and pyrolyzed prior to GC-MS analysis. The compounds were monitored using selected ion monitoring at m/z 232 and m/z 190 for acetyltelluronium and telluronium choline, respectively, and at m/z 236 and m/z 194 for the analogous deuterated internal standards. The assay was linear over a range of 20 pmol-20 nmol of compound taken through the assay. PMID:8130881

1993-12-31

346

Sustainability evaluation of limestone geothermal reservoirs with extended production histories in Beijing and Tianjin, China  

British Library Electronic Table of Contents (United Kingdom)

Sustainable development of geothermal resources is the key to prolong the commercial life of geothermal fields. This paper uses two well-known geothermal fields in China, with long histories of production, to demonstrate how sustainability can be quantitatively evaluated, and to highlight the essential differences between sustainable and non-sustainable development schemes. After examining the complex nature of sustainability evaluation, fuzzy synthetic evaluation is applied as a tool for the quantitative sustainability rating of geothermal reservoirs. The evaluation procedures include systemic criteria selection, weighing, individual criterion evaluation and finally final multi-criterion decision analysis evaluation. The sustainability of a limestone reservoir in the urban sector of Tianj...

2011-01-01

347

Studies on the acidity of mordenite and ZSM-5. 2. Loss of Broensted acidity by dehydroxylation and dealumination  

Science.gov (United States)

Quantitative determination of Broensted acid site concentrations in calcined H-mordenite and H-ZSM-5 by means of conductometric titration and infrared spectroscopy reveals that the concentration of Broensted acid sites present is lower than would be expected on the basis of the aluminum content. This discrepancy is attributed to dealumination and dehydroxylation processes occurring during calcination. A model is proposed according to which the degree of these processes strongly depends on the concentration of vicinal aluminum T sites in the zeolite: Broensted acid sites associated with these T sites are lost, and the remaining Broensted acidity is related to the concentration of the (remaining) isolated aluminum T sites. This model quantitatively correlates the experimentally determined concentration of Broensted acid sites with the concentration of isolated aluminum T sites. 33 refs., 4 figs., 2 tabs.

1993-01-14

348

Structural aging program to assess the adequacy of critical concrete components in nuclear power plants  

International Nuclear Information System (INIS)

The Structural Aging (SAG) Program is carried out by the Oak Ridge National Laboratory (ORNL) under sponsorship of the United States Nuclear Regulatory Commission (USNRC). The Program has evolved from preliminary studies conducted to evaluate the long-term environmental challenges to light-water reactor safety-related concrete civil structures. An important conclusion of these studies was that a damage methodology, which can provide a quantitative measure of a concrete structure's durability with respect to potential future requirements, needs to be developed. Under the SAG Program, this issue is being addressed through: establishment of a structural materials information center, evaluation of structural component assessment and repair technologies, and development of a quantitative methodology for structural aging determinations. Progress to date of each of these activities is presented as well as future plans. 7 refs., 5 figs.

1989-08-14

349

Quantitative non-destructive evaluation of high-temperature superconducting materials  

Energy Technology Data Exchange (ETDEWEB)

Even though the currently intensive research efforts on high- temperature superconducting materials have not yet converged on a well specified practical material, the indications are that such a material may be quite brittle, anisotropic, and may contain many flaws such as microcracks and voids at grain boundaries. Consequently, practical applications of high temperature superconducting materials will require a very careful strength analysis based on fracture mechanics considerations. Because of the high sensitivity of the strength of such materials to the presence of defects, methods of quantitative non-destructive evaluation may be expected to play an important role in strength determinations. This proposal is concerned with the use of ultrasonic methods to detect and characterize isolated cracks, clusters of microcracks and microcracks distributed throughout the material. Particular attention has been, and will continue to be devoted to relating ultrasonic ...

1991-06-14

350

Quantitative bone scintigraphy. A methodological evaluation in prostate cancer  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate a simple method for quantification of focal activity in bone scintigraphy (BS). Material and methods: The gamma camera was calibrated using a phantom. Quantitative bone scintigraphy (QBS) was performed on 11 men recently diagnosed with prostate cancer (PCa), for whom routine BS showed involvement of the skeleton. Following endocrine therapy for 4 to 8 months, a second QBS was performed. Changes in QBS values were then compared to changes in serum levels of prostate-specific antigen (PSA). Results: PSA response indicating regression of PCa was accompanied by a decrease in the QBS value in 8 of the 11 patients. The overall mean error of the QBS values was 15%. conclusion: QBS according to this method is a relatively simple procedure that might contribute to objective evaluation of therapeutic effects in skeletal metastases, although its validity must be tested in a larger clinical material.

2000-03-01

351

Quantitative bone scintigraphy. A methodological evaluation in prostate cancer  

International Nuclear Information System (INIS)

Purpose: To evaluate a simple method for quantification of focal activity in bone scintigraphy (BS). Material and methods: The gamma camera was calibrated using a phantom. Quantitative bone scintigraphy (QBS) was performed on 11 men recently diagnosed with prostate cancer (PCa), for whom routine BS showed involvement of the skeleton. Following endocrine therapy for 4 to 8 months, a second QBS was performed. Changes in QBS values were then compared to changes in serum levels of prostate-specific antigen (PSA). Results: PSA response indicating regression of PCa was accompanied by a decrease in the QBS value in 8 of the 11 patients. The overall mean error of the QBS values was 15%. conclusion: QBS according to this method is a relatively simple procedure that might contribute to objective evaluation of therapeutic effects in skeletal metastases, although its validity must be tested in a larger clinical material

2000-03-01

352

Quantitative analysis of X-Ray Microtomography images of metal powders in the course of sintering  

Energy Technology Data Exchange (ETDEWEB)

In situ X-Ray microtomography offers new opportunities for analysing sintering mechanisms since it allows 3D observation of the microstructural evolution of the powder all along a sintering cycle. With synchrotron radiation at ESRF, a 3D image with a resolution of 2 {mu}m can be obtained in about one minute. In addition to the visual examination of the images, relevant microstructural parameters can be measured through quantitative image analysis using recently developed tools. In this paper the results obtained with two materials, loose copper powder and compacted steel powder, are resumed. For copper powder, the dispersion of local parameters such as particle co-ordination number and porosity is investigated. Concerning steel compacts, data about pore morphology evolution and on local strains provides clues for understanding the anisotropic shrinkage of such compacts. (authors)

2005-07-01

353

Quantitative Computed Tomography (QCT) of vertebral spongiosa. Evaluation of a possible method for managment of postmenopausal osteoporosis (PMO)  

International Nuclear Information System (INIS)

A Quantitative Computed Tomography (QCT) method, simplifying the well-known technique proposed by Genant (1982) and applied to a standard third generation whole body CT scanner is described. This technique was applied in the measurement of the trabecular bone which has high sensitivity for metabolic changes. The BMC (Bone Mineral Content) measured in different groups of subjects (healthy postmenopausal patients versus women with postmenopausal osteoporosis) showed a highly significant difference (p<0.001). The precision of repositioning (coefficient of variation 1.8% to 2.3%, obtained in healty male patients) and the good, linear relationship computed from the phantom values, minimize measurement errors. Since this method is quickly applied and involves low-dose radiation-exposure, it could be introduced in the clinical study of metabolic bone diseases.

1987-01-01

354

Partial unmixing as a tool for single surface class detection and time series analysis  

British Library Electronic Table of Contents (United Kingdom)

In this paper we present the results of time series analysis for a coal mining region based on partial unmixing. We test the method also known as mixture tuned matched filtering on an eight image Landsat 5 TM and Landsat 7 ETM+ time series covering the period from 1987 to 2003. Common change detection methods often include the comparison of two interactively generated classification results, such as derived from Maximum Likelihood classification. These approaches often yield highly accurate results. However, disadvantages include a strong analyst bias and hardly repeatable results. For a quantitative monitoring of a single surface class' development over time they are often not recommendable. Our goal was to test an unbiased quantitative way to assess the development of coal surfaces, such...

2008-01-01

355

NEXAFS microscopy of polymeric materials: Successes and challenges encountered when characterizing organic devices  

Energy Technology Data Exchange (ETDEWEB)

We summarize recent developments in x-ray microscopy of polymers by focusing on the characterization of organic electronic devices. The quantitative compositions of model polymer blends have been mapped at a resolution of {approx}35 nm. Since it could be inferred that these devices have structures smaller than 35 nm, quantitative compositional mapping at length scales below the present resolution limit of x-ray microscopy is required. Organic devices thus serve to both highlight the success of NEXAFS microscopy to date, but to also outline the very real need for higher spatial resolution. New approaches to create improved optics or different acquisition modalities are required if x-ray microscopy is to make sustained contributions to such an important area of research as organic devices.

2009-09-01

356

Identification and robust water level control of horizontal steam generators using quantitative feedback theory  

British Library Electronic Table of Contents (United Kingdom)

In this paper, a robust water level control system for the horizontal steam generator (SG) using the quantitative feedback theory (QFT) method is presented. To design a robust QFT controller for the nonlinear uncertain SG, control oriented linear models are identified. Then, the nonlinear system is modeled as an uncertain linear time invariant (LTI) system. The robust designed controller is applied to the nonlinear plant model. This nonlinear model is based on a locally linear neuro-fuzzy (LLNF) model. This model is trained using the locally linear model tree (LOLIMOT) algorithm. Finally, simulation results are employed to show the effectiveness of the designed QFT level controller. It is shown that it will ensure the entire designer's water level closed loop specifications.

2011-01-01

357

Finite-duration Seeding Effects in Powerful Backward Raman Amplifiers  

Energy Technology Data Exchange (ETDEWEB)

In the process of backward Raman amplification (BRA), the leading layers of the seed laser pulse can shadow the rear layers, thus weakening the effective seeding power and affecting parameters of output pulses in BRA. We study this effect numerically and also analytically by approximating the pumped pulse by the ''*-pulse'' manifold of self-similar solutions. We determine how the pumped pulse projection moves within the *-pulse manifold, and describe quantitatively the effective seeding power evolution. Our results extend the quantitative theory of BRA to regimes where the effective seeding power varies substantially during the amplification. These results might be of broader interest, since the basic equations, are general equations for resonant 3-wave interactions.

2003-07-14

358

Cottonseed feeding delivers sufficient quantities of gossypol as a male deer contraceptive  

British Library Electronic Table of Contents (United Kingdom)

To define the quantitative and qualitative effects of gossypol (GP) on deer (Cervus elaphus) semen, the animals were fed cottonseed (CS). Adult stags each received 350?g of CS for 109?days. Animals received 15?mg of gossypol per kilogram body weight per day. Quantitative and qualitative parameters of experimental ejaculates (n?=?182) were compared to ejaculates (n?=?571) of control animals (n?=?5) collected during three previous natural reproductive seasons. Ejaculate fractions were evaluated by classical methods used in domestic animals. In this paper, we show that mature male deer fed CS exhibited morphological changes and decreased motility of spermatozoa and abnormalities in spermatogenesis. Radioimmunoassay measured concentrations of various steroid hormones (T-testosterone, A4-andros...

2008-01-01

359

Correlation, hierarchies, and networks in financial markets  

CERN Document Server

We discuss some methods to quantitatively investigate the properties of correlation matrices. Correlation matrices play an important role in portfolio optimization and in several other quantitative descriptions of asset price dynamics in financial markets. Specifically, we discuss how to define and obtain hierarchical trees, correlation based trees and networks from a correlation matrix. The hierarchical clustering and other procedures performed on the correlation matrix to detect statistically reliable aspects of the correlation matrix are seen as filtering procedures of the correlation matrix. We also discuss a method to associate a hierarchically nested factor model to a hierarchical tree obtained from a correlation matrix. The information retained in filtering procedures and its stability with respect to statistical fluctuations is quantified by using the Kullback-Leibler distance.

2008-01-01

360

Combined In Vivo/In Silico Study of Mechanobiological Mechanisms During Endochondral Ossification in Bone Healing  

British Library Electronic Table of Contents (United Kingdom)

Mechanobiological theories have been introduced to illustrate the interaction between biology and the local mechanical environment during bone healing. Although several theories have been proposed, a quantitative validation using histomorphometric data is still missing. In this study, in vivo histological data based on an ovine animal experiment was quantified and used to validate bone healing simulations focussing on the endochondral ossification process. The bone formation at different callus regions (periosteal and endosteal bone at the medial and lateral side) was analyzed from in vivo data and quantitatively compared with in silico results. A histomorphometric difference was found in medial and lateral hard callus formation 3 weeks after osteotomy. However, the same amount of new bone...

2011-01-01

361

CRC handbook of NASA future missions and payloads  

Energy Technology Data Exchange (ETDEWEB)

The author presents a detailed and quantitative description of all of the programs, systems, sensors and experiments associated with the next 30 years of space endeavors by the National Aeronautics and Space Administration. Derived from the fifth issue of the NASA Space Systems Technology Model, the missions and payloads are categorized by applications area: solar system exploration, astrophysics, earth sciences, communications, space transportation and utilization of the space environment. Far-term missions are described as opportunity missions and landmark missions, for the distant future. Technology requirements are collected by discipline: power, propulsion, materials, structures, information systems, navigation, guidance and control. Payload technology requirements are organized by instrument sensing range. This information defines in quantitative terms, the opportunities and limits for future civilian space system capabilities.

1986-01-01

362

Assessment of Low Quantitative Ultrasound Values of Calcaneus in Chinese Mainland Women  

British Library Electronic Table of Contents (United Kingdom)

Calcaneus quantitative ultrasound (QUS) assessment is a safe and reliable method for evaluating skeletal status. Until now, considerable data have been accumulated on the distribution of QUS in Caucasian populations, whereas such data are still insufficient in Asian populations, especially in Chinese mainland. The present study aimed to obtain the distribution characteristic of calcaneus QUS in healthy Chinese women, and to further investigate the distribution of low bone mass by QUS stiffness index (SI). This study included 2,498 healthy Chinese females aged 10-87 yr. The QUS exhibited a characteristic mild rise and then fall pattern with increasing age. Age, body height, and weight were significant influencing factors on SI, especially age and weight. The prevalence of osteoporosis detec...

2006-01-01

363

Advanced distillation curve measurements for corrosive fluids: Application to two crude oils  

British Library Electronic Table of Contents (United Kingdom)

We have recently introduced several important improvements in the measurement of distillation curves for complex fluids. The modifications include a composition-explicit data channel for each distillate fraction (for both qualitative and quantitative analysis) and corrosivity assessment of each distillate fraction. The composition-explicit information is achieved with a new sampling approach that allows precise qualitative as well as quantitative analyses of each fraction, on the fly. We have applied the new method to a variety of fluids, including simple n-alkanes, rocket propellant, gasoline, jet fuels, and a hydrocarbon fluid made corrosive with dissolved hydrogen sulfide. In the current contribution, we present the application of the advanced distillation curve method to two samples of...

2008-01-01

364

Ab initio study on pressure-induced change of effective Coulomb interaction in superconducting yttrium  

Science.gov (United States)

Ab initio lattice dynamics based on linear response method are performed for high pressure phase of yttrium to describe electron-phonon coupling and subsequent superconducting behavior. The critical temperature Tc in fcc-Y increases monotonically with pressure up to 9.25 K at 31 GPa, which is quantitatively in excellent agreement with two quasihydrostatic experiments and is qualitatively compatible with recent experiments. The excellent agreement with experiments gives us a better understanding of the effective pseudopotential ?* as well as spectral function ?2(?)F(?) in yttrium. These results demonstrate that there exists strong electron-phonon coupling in Y within the studied pressure regime, and for lower pressure electron correlation becomes stronger. Generally, it is found that superconductivity in yttrium under pressure can be described quantitatively within standard theory of phonon-mediated superconductivity.

2010-01-01

365

A numerical study of expected accuracy and precision in Calibration-Free Laser-Induced Breakdown Spectroscopy in the assumption of ideal analytical plasma  

British Library Electronic Table of Contents (United Kingdom)

Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experi...

2007-01-01

366

A novel volumetric method for quantitation of titanium dioxide in cosmetics  

British Library Electronic Table of Contents (United Kingdom)

Nowadays there are many sun-protection cosmetics incorporating organic or inorganic UV filters as active ingredients. Chemically stable inorganic sunscreen agents, usually metal oxides, are widely employed in high-SPF (sun protection factor) products. Titanium dioxide is one of the most frequently used inorganic UV filters. It has been used as a pigment for a long period of cosmetic history. With the development of micronization techniques, it has become possible to incorporate titanium dioxide in sunscreen formulations without the previous whitening effect, and hence its use in cosmetics has become an important research topic. However, there are very few works related to quantitation of titanium dioxide in sunscreen products. In this research, we analysed the amounts of titanium dioxide i...

2007-01-01

367

X-ray spectral microanalysis of component redistribution in finely dispersed two-phase alloys  

International Nuclear Information System (INIS)

It is shown that it is necessary to take into account locality of the analysis and to introduce additional corrections for partial capture of matrix and fluorescent subexcitation by matrix during quantitative X-ray spectral microanalysis of finely dispersed materials. Cast two-phase (#alpha#+#beta#) titanium alloy VT3-1 is chosen as an investigation object.

368

Wind ripple analysis  

Science.gov (United States)

Efficient and economical utilization of wind power will require the ability to measure and ultimately predict the effects fluctuations in the incident wind will have on a wind turbine. In order to quantitatively assesss these effects, experimental techniques have been developed which allow analysis of full-scale performance of wind turbines with particular emphasis on the effects caused by turbulence in the incident wind. Examples of these techniques are presented using data from the DOE/Sandia Vertical Axis Wind Turbine (VAWT) program.

1981-01-01

369

Topological excitations and second order transitions in 3D O(N) models  

Energy Technology Data Exchange (ETDEWEB)

I discuss several examples of critical phenomena in O(N) models where topological excitations play an important role at criticality. I focus particular attention on the O(2) model in 3D, where recent measurements of the vortex string length distribution in equilibrium suggest the existence of a quantitative picture of the critical behavior in terms of defects. The compatibility of this perspective with renormalization group predictions is examined.

2001-01-01

370

Theoretical studies of Cerro Prieto brines chemical equilibria  

Energy Technology Data Exchange (ETDEWEB)

A chemical equilibrium model is used, implemented in a compact FORTRAN package called HITEQ, to investigate possible mineral deposition related to prereinjection treatment of Cerro Prieto brines for silica removal. Large saturation ratios of the treated brines with respect to several minerals are indicated by these computations. As a remedy, an inexpensive CO/sub 2/ removal scheme aimed at inhibiting carbonate mineral precipitation is proposed. This scheme is quantitatively discussed with the aid of HITEQ. It is concluded that the proposed treatment is both technically and economically feasible.

1980-02-01

371

The Phenomics and Expression Quantitative Trait Locus Mapping of Brain Transcriptomes Regulating Adaptive Divergence in Lake Whitefish Species Pairs (Coregonus sp.)  

UK PubMed Central (United Kingdom)

We used microarrays and a previously established linkage map to localize the genetic determinants of brain gene expression for a backcross family of lake whitefish species pairs (Coregonus sp.). Our...Full Text Available

2008-09-01

372

Terms Beginning With \\  

Wastenet

... Risk (Adverse) for Endangered Species: Risk to aquatic species if anticipated pesticide residue levels equal one-fifth of LD10 or one-tenth of LC50; risk to ...terrestrial species if anticipated pesticide residue levels equal one-fifth of LC10 or one-tenth of LC50. Risk Assessment: Qualitative and quantitative evaluation of the ... Risk for Non-Endangered Species: Risk to species if anticipated pesticide residue levels are equal to or greater than LC50. Risk Management: The process ...

373

Structure of fragment energy spectra in spontaneous fission of sup 242 Cm and fast-neutron fission of sup 242 m Am  

Energy Technology Data Exchange (ETDEWEB)

A technique for measurement of the energy spectra of fission fragments is discussed. The fine structure found in the spectra of fragments from spontaneous fission of {sup 242}Cm and fast-neutron fission of {sup 242{ital m}}Am is analyzed. The quantitative parameters of the structure and their analogy with the characteristics of cold fission are discussed.

1989-05-01

374

Spectrophotometric technique quantitatively determines NaMBT inhibitor in ethylene glycol-water solutions  

Science.gov (United States)

Spectrophotometric method, using a ratio-recording ultraviolet-absorption spectrophotometer, permits analysis of NaMBT in ethylene glycol-water solutions with high accuracy. It reduces analysis time, requires smaller samples, and is able to detect extremely small concentrations of mercaptobenzothiazole.

1967-01-01

375

Spatiotemporal Analysis of Environmental Radioactivity in Soil around Nuclear Plant  

Energy Technology Data Exchange (ETDEWEB)

Geostatistical techniques make it possible to qualitatively and quantitatively analyze spatiotemporal inherent characteristics of environmental radiation or radioactivity. Spatial patterns and trend analysis of environmental radioactivity, e.g., {sup 137}Cs and {sup 40}K, in soil around nuclear facilities (Kori, Wolsung, Yeonggwang, Uljin, and Daejeon) will be investigated and discussed.

2006-07-01

376

Some insights from total collapse  

CERN Document Server

We discuss the Sundman-Weierstrass theorem of total collapse in its historical context. This remarkable and relatively simple result, a type of stability criterion, is at the crossroads of some interesting developments in the gravitation Newtonian N-body problem. We use it as motivation to explore the connections to such important concepts as integrability, singularities and tyipicality in order to gain some insight on the transition from a predominantly quantitative to a novel qualitative approach to dynamical problems that took place at the end of the 19th century.

2008-01-01

377

Single-crystalline cadmium telluride anodic oxidation kinetics  

Science.gov (United States)

The authors have determined quantitative characteristics for oxide films forming on (111) surfaces of cadmium telluride single crystals on anodic oxidation in 0.1 M KOH: the constants in the Guenterschulze-Betz equation and the film growth constant, which is 2.4 nm/V, from which the activation energy for cadmium telluride electrooxidation has been calculated.

1988-10-10

378

SIV antigen immunization induces transient antigen-specific T cell responses and selectively activates viral replication in draining lymph nodes in retroviral suppressed rhesus macaques  

UK PubMed Central (United Kingdom)

BackgroundHIV infection causes a qualitative and quantitative loss of CD4+ T cell immunity. The institution of anti-retroviral therapy (ART) restores CD4+ T...Full Text Available

379

Risk orientated analysis of the SNR 300  

International Nuclear Information System (INIS)

To make a quantitative comparison of risks between the SNR 300 and a modern PWR (Biblis B), the consequences of an accident or the extent of damage of a release of radionuclides to the environment due to an accident are estimated by computer programs for accident consequence models. The accident analysis includes an analysis of events for Bethe-Tait accidents with failure of the outer containment. The FGSB release rates are compared with those of the Society for Reactor Safety (GRS). (HP).

380

Quantitative x ray microanalysis of pulmonary mineral particles in a patient with pneumoconiosis and two primary lung tumours.  

UK PubMed Central (United Kingdom)

The right upper lung lobe of a 74 year old man was resected for a central tumour. Two primary cancers were found; a central small cell carcinoma and a peripheral squamous cell carcinoma. In addition,...Full Text Available

1984-11-01

381

Quantitative transfer of the molybdenum cofactor from xanthine oxidase and from sulphite oxidase to the deficient enzyme of the nit-1 mutant of Neurospora crassa to yield active nitrate reductase.  

UK PubMed Central (United Kingdom)

An assay method is described for measurement of absolute concentrations of the molybdenum cofactor, based on complementation of the defective nitrate reductase ('apo nitrate reductase') in extracts...Full Text Available

1984-04-15

382

Quantitative spectroscopy of close binary stars  

CERN Document Server

The method of spectral disentangling has now created the opportunity for studying the chemical composition in previously inaccessible components of binary and multiple stars. This in turn makes it possible to trace their chemical evolution, a vital aspect in understanding the evolution of stellar systems. We review different ways to reconstruct individual spectra from eclipsing and non-eclipsing systems, and then concentrate on some recent applications to detached binaries with high-mass and intermediate-mass stars, and Algol-type mass-transfer systems.

2011-01-01

383

Quantitative pharmacological analysis of 2-125I-iodomelatonin binding sites in discrete areas of the chicken brain  

Energy Technology Data Exchange (ETDEWEB)

The authors have localized and characterized 2-125I-iodomelatonin binding sites in the chicken brain using in vitro quantitative autoradiography. Binding sites were widely distributed throughout the chicken brain, predominantly in regions associated with the visual system. The specific binding of 2-125I-iodomelatonin to discrete chicken brain areas was found to be saturable, reversible, and of high affinity. The specific binding of 2-125I-iodomelatonin (75 pm) was quantitated for 40 identifiable brain regions. Eight brain regions were chosen for binding characterization and pharmacological analysis: optic tectum, Edinger-Westphal nucleus, oculomotor nucleus, nucleus rotundus, ventral supraoptic decussation, ventrolateral geniculate nucleus, neostriatum, and ectostriatum. These regions showed no rostral-caudal gradient in 2-125I-iodomelatonin specific binding, and saturation analysis revealed a single class of high-affinity sites with KD values ...

1991-09-01

384

Quantitative imaging of turbulent and reacting flows  

Energy Technology Data Exchange (ETDEWEB)

Quantitative digital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitative image data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial dynamic range, signal-to-noise ratio and spatial resolution in the imaging system as well as developing ...

1993-12-01

385

Quantitative evaluation of simultaneous reconstruction with model-based crosstalk compensation for 99mTc?123I dual-isotope simultaneous acquisition brain SPECT  

UK PubMed Central (United Kingdom)

A model-based method has been previously developed to estimate and compensate for the crosstalk and downscatter contamination in simultaneous 123I∕99mTc dual-isotope SPECT...Full Text Available

2009-06-01

386

Quantitative electron-paramagnetic-resonance measurements of the electron-transfer components of the photosystem-I reaction centre. The reaction-centre chlorophyll (P700), the primary electron acceptor X and bound iron-sulphur centre A.  

UK PubMed Central (United Kingdom)

An e.p.r. spectrum of the reduced form of the electron-transport component (X), thought to be the primary electron acceptor of Photosystem I, was obtained. By using line-shape simulations of this component...Full Text Available

1978-02-15

387

Quantitative bone and 67Ga scintigraphy in the differentiation of necrotizing external otitis from severe external otitis  

Energy Technology Data Exchange (ETDEWEB)

Qualitative technetium Tc 99m bone scintigraphy using phosphate compounds and gallium 67 scintigraphy were described as a helpful means in diagnosing necrotizing external otitis (NEO). They were, however, claimed to be nonspecific. Quantitative Tc 99m methylene diphosphonate bone scintigraphy and gallium 67 scintigraphy were performed in eight patients with NEO and in 20 patients with severe external otitis, in order to prove usefulness of scintigraphy in the diagnosis of NEO. Ratios of lesion to nonlesion for bone scintigraphy were 1.67 {plus minus} 0.16 in patients with NEO and 1.08 {plus minus} 0.09 in patients with severe external otitis, and for gallium 67 scintigraphy they were 1.35 {plus minus} 0.24 in NEO patients and 1.05 {plus minus} 0.03 in patients with severe external otitis. There was no difference in uptake between diabetic patients with severe external otitis and nondiabetic patients. The scintigraphic studies were also evaluated using a qualitative ...

1991-06-01

388

Quantitative bone and 67Ga scintigraphy in the differentiation of necrotizing external otitis from severe external otitis  

International Nuclear Information System (INIS)

Qualitative technetium Tc 99m bone scintigraphy using phosphate compounds and gallium 67 scintigraphy were described as a helpful means in diagnosing necrotizing external otitis (NEO). They were, however, claimed to be nonspecific. Quantitative Tc 99m methylene diphosphonate bone scintigraphy and gallium 67 scintigraphy were performed in eight patients with NEO and in 20 patients with severe external otitis, in order to prove usefulness of scintigraphy in the diagnosis of NEO. Ratios of lesion to nonlesion for bone scintigraphy were 1.67 #+-# 0.16 in patients with NEO and 1.08 #+-# 0.09 in patients with severe external otitis, and for gallium 67 scintigraphy they were 1.35 #+-# 0.24 in NEO patients and 1.05 #+-# 0.03 in patients with severe external otitis. There was no difference in uptake between diabetic patients with severe external otitis and nondiabetic patients. The scintigraphic studies were also evaluated using a qualitative scoring method (scores 0 to ...

389

Quantitative and empirical demonstration of the Matthew effect in a study of career longevity  

UK PubMed Central (United Kingdom)

The Matthew effect refers to the adage written some two-thousand years ago in the Gospel of St. Matthew: “For to all those who have, more will be given.” Even two millennia later, this...Full Text Available

2011-01-04

390

Quantitative Trait Loci for Grain Yield and Adaptation of Durum Wheat (Triticum durum Desf.) Across a Wide Range of Water Availability  

UK PubMed Central (United Kingdom)

Grain yield is a major goal for the improvement of durum wheat, particularly in drought-prone areas. In this study, the genetic basis of grain yield (GY), heading date (HD), and plant height (PH) was...Full Text Available

2008-01-01

391

Quantitative 31P NMR Spectroscopy and 1H MRI Measurements of Bone Mineral and Matrix Density Differentiate Metabolic Bone Diseases in Rat Models  

UK PubMed Central (United Kingdom)

In this study, bone mineral density (BMD) of normal (CON), ovariectomized (OVX) and partially nephrectomized (NFR) rats was measured by 31P NMR spectroscopy; bone matrix density was...Full Text Available

2010-06-01

392

Quantitation of transcribing native simian virus 40 minichromosomes extracted from CV1 cells late in infection.  

UK PubMed Central (United Kingdom)

Simian virus 40 transcriptional complexes could be extracted from CV1 cells late in infection and separated from the bulk of inactive viral chromatin. Sucrose gradient sedimentation, cesium sulfate...Full Text Available

1981-04-01

393

Principles of the coprecipitation of thorium and yttrium with organicinorganic salts of molybdenum polyacids  

Energy Technology Data Exchange (ETDEWEB)

This paper advances hypotheses on the chemistry of the interaction of thorium and yttrium with organic-inorganic salts of molybdenum polyacids. On the basis of an analysis of the data of an adsorption experiment and the quantitative relationships that follow from the law of mass action, it is shown that thorium is absorbed by the solid phase by coprecipitation with the participation of complex formation, while the coprecipitation of yttrium with salts of polyacids is due to a reaction of ion exchange chemisorption.

1986-03-01

394

Position-Dependent Electrostatic Protection against Protein Aggregation  

British Library Electronic Table of Contents (United Kingdom)

Proteins with a high propensity to aggregate can be largely prevented from doing so with surprisingly small changes to their primary structure. By using a combination of rational design and quantitative measurements of aggregation rates, we show that adding a single charge in specific "gatekeeper" regions is sufficient to change the timescale for amyloid fibril growth from minutes to weeks, thereby dramatically reducing the efficiency of this process.

2009-01-01

395

Phenomenological combustion model for a quiescent chamber diesel engine  

Energy Technology Data Exchange (ETDEWEB)

A phenomenological model is presented for prediction of the combustion characteristics of a quiescent chamber diesel engine. Predictions with the model have shown acceptable agreement with a range of experimental data. The major physical processes controlling combustion have been characterized, and the dominant role of air entrainment and turbulent mixing confirmed quantitatively. 45 refs.

1981-10-01

396

Ozone hazards incurred in #gamma#-plant operation  

International Nuclear Information System (INIS)

The irradiation of air produces some toxic gases such as ozone, nitric oxide, nitrogen dioxide, nitrogen trioxide, nitrogen tetroxide, nitric anhydride and nitrous oxide. Of these gases, ozone is the most important because of its toxicity and may be produced in such quantities as to constitute a health hazard within the irradiation room. The toxicity, and explosive characteristics of ozone and quantitative aspects of ozone production are discussed and ventilation requirements considered. (U.K.).

397

On the CSFT approach to localized closed string tachyons  

Energy Technology Data Exchange (ETDEWEB)

We compute the potential for localized closed string tachyons in bosonic string theory on the orbifold C/Z{sub 4} using level-truncated closed string field theory. The critical points of the potential exhibit features which agree with their conjectured identification as lower-order orbifolds. However this case also raises some questions regarding the quantitative predictions associated with these conjectures. (author)

2005-01-01

398

Nonformity of the electron density in amorphous silicon films  

Energy Technology Data Exchange (ETDEWEB)

The authors study the nonuniformity of a-Si:H films obtained by the method of vacuum condensation, with the help of x-ray small-angle scattering (SLS) and transmission electron microscopy. Films of hydrogenated amorphous silicon are greatest interest, because the electronic properties of this material can be controlled by doping. As a result of the compensation of the ruptured bonds, and possibly, effects of melting, the properties of such films are analogous to those of singlecrystalline silicon. XLS enables a quantitative determination of the prameters of the regions of low electron density (RLD) in such objects.

1985-12-01

399

Methods and results of gas chromatographicmass spectrometric determination of volatile organic substances in an urban atmosphere  

Energy Technology Data Exchange (ETDEWEB)

The method and results of the quantitative gas chromatographic determination of volatile organic substances in an urban atmosphere are presented. The concentration of organic substances was determined by using a mixed adsorber consisting of graphitized thermal carbon black and activated charcoal modified by pyrocarbon. Average, maximum and minimum concentrations of constant organic components in the atmosphere of Leningrad as a typical large industrial city are reported.

1983-01-01

400

Mathematical and physical model of steam-water mixture flow in horizontal steam generator  

International Nuclear Information System (INIS)

A mathematical and physical model was constructed describing the hydrodynamics of the two-phase mixture in the horizontal steam generator. The HP 9830 A desk-top calculator was used for the computations. The output variable of the solution was the level shape. A quantitative and qualitative comparison was made of the results of computations and experimental data. (author).

1982-10-01

401

Magnetic resonance imaging of stents. Quantitative in vitro examination at 3 Tesla; Magnetresonanztomographie von Stents. Quantitative MR-Untersuchungen in vitro bei 3 Tesla  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to qualitatively and quantitatively study MR artifacts of various stents on the basis of in vitro experiments. We were particularly interested whether sequence type and orientation of the stent with respect to the static magnetic field influences the artifact. We examined 18 stents of different material (nitinol, stainless steel, cobalt alloy), different design of the stent meshes (AccuLink, OmniLink, DynaLink, Xact, Protoge, Wallstent Monorail), different diameter (5-10 mm) and different length (18-58 mm) with a turbo spin echo (TSE), a 2D-fast low angle shot (FLASH) and a 3D-FLASH sequence. The MR images were examined qualitatively with respect to possible artifacts. Furthermore we examined the MR data quantitatively: The contrast-noise-ratio (CNR) was determined both within the stent and outside (within the tube); based on these values we calculated the transparency factor P, furthermore we calculated the apparent ...

2009-07-01

402

Kinetic Parameters of Efflux of Penicillins by the Multidrug Efflux Transporter AcrAB-TolC of Escherichia coli?  

UK PubMed Central (United Kingdom)

The multidrug efflux transporter AcrAB-TolC is known to pump out a diverse range of antibiotics, including β-lactams. However, the kinetic constants of the efflux process, needed for the quantitative...Full Text Available

2010-05-01

403

Internal emitter limits for iodine, radium and radon daughters  

Energy Technology Data Exchange (ETDEWEB)

This paper identifies some of the issues which arise in the consideration of the derivation of new limits on exposure to internal emitters. Basic and secondary radiation protection limits are discussed. Terms are defined and applied to the limitation of risk from stochastic effects. Non-stochastic data for specific internal emitters (/sup 131/I and the radium isotopes) are presented. Emphasis is placed on the quantitative aspects of the limit setting problem. 65 references, 2 figures, 12 tables.

1984-08-15

404

Increased bone radiotracer uptake in renal osteodystrophy  

Energy Technology Data Exchange (ETDEWEB)

Bone radiotracer uptake in renal osteodystrophy was investigated in 35 dialysis patients by correlating the results of quantitative bone scintigraphy with those of biochemical and bone morphometric studies. There were highly significant correlations (P < 0.001) between the total skeletal activity and the biochemical (iPTH and alkaline phosphatase), and histologic parameters of hyperparathyroidism. These clinical results strongly suggest that increased bone turnover i.e. hyperparathyroidism, rather than osteomalacia is the major cause of increased skeletal uptake in renal osteodystrophy.

1982-04-01

405

In Pursuit of Spreadsheet Excellence  

CERN Document Server

The first fully-documented study into the quantitative impact of errors in operational spreadsheets identified an interesting anomaly. One of the five participating organisations involved in the study contributed a set of five spreadsheets of such quality that they set the organisation apart in a statistical sense. This virtuoso performance gave rise to a simple sampling test - The Clean Sheet Test - which can be used to objectively evaluate if an organisation is in control of the spreadsheets it is using in important processes such as financial reporting.

2008-01-01

406

Genetic and somatic risks in X-ray diagnosis  

International Nuclear Information System (INIS)

Based on a literature study an actual summary of the risk-utility problems in X-ray diagnosis is outlined due to the Recommendations of the International Commission for Radiation Protection (ICRP publication 26/1977). Papers demonstrating quantitative assessment of the somatic and genetical risk in X-ray examination are preferably cited and evaluated. It is concluded that the somatic and genetical risk is low in diagnostic ratiology. However, it must not be neglected and has always to be compared to the utility of an examination as well as to other risks of the examination. (author).

1982-01-01

407

Free convection heat and mass transfer to steady flow in a semi-infinite vertical porous medium  

Science.gov (United States)

Analytical solutions are derived for a flow in a semi-infinite vertical porous medium with heat and mass transfer. When the temperature and mass concentration are uniform a constant pressure is possible and sustains a fully developed flow. Thereafter there is a small perturbation on the wall temperature and concentration and the subsequent two-dimensional problem is tackled for a large Prandtl number, free convection parameters and small Reynolds number. The heat transfer rate at the wall is discussed quantitatively.

1988-02-01

408

Effect of resin size on HETP in separation of isotopes by chromatography  

Energy Technology Data Exchange (ETDEWEB)

In this report, the quantitative relation between the height equivalent to a theoretical plate (HETP) and the size of ion exchange resin is studied by enriching lithium isotopes with high pressure ion exchange displacement chromatography. The dependence of HETP on the size of the resin can be expressed as H = C x (anti r)sup( ) in which = 2.4 and it is found that Snyder's equation is suitable for such a system of isotope separation as may be explained by the simple displacement mechanism.

1985-02-01

409

Domain structure of ferrite-garnet crystalline plates (111) with uniaxial anisotropy  

Energy Technology Data Exchange (ETDEWEB)

Magnetic field, thickness and magnetic forming effect on general mode and quantitative parameters of the domain structure (DS) of ferrite-garnet (EuEr)/sub 3/(FeGa)/sub 5/O/sub 12/ monocrystalline plates (111) is investigated. Field interval of circle (cone) and ring domain stability is determined. It is shown that DS of ferrite-garnet crystals with uniaxial an6sotropy has some peculiarities, that can be explained by cubic anisotropy effect.

1982-03-01

410

Distribution of Indole-3-Acetic Acid and the Occurrence of Its Alkali-Labile Conjugates in the Extraxylary Region of Pinus sylvestris Stems 1  

UK PubMed Central (United Kingdom)

Free and conjugated indole-3-acetic acid (IAA) were measured by quantitative gas chromatography-selected ion monitoringmass spectrometry in the extraxylary region of the stem of large Pinus...Full Text Available

1990-08-01

411

Development and application of a gamma scanning system for LLW and MLW packages  

International Nuclear Information System (INIS)

The report describes the studies carried out to design a non-destructive system for the radiological characterization of packages containing LLW and MLW. This technique is applied for quantitative and qualitative gamma emitters determination in packages with homogeneous and heterogeneous matrices as well as the development of a maximum activity points location system. Development involves also the automatization for its industrial use.

1993-09-05

412

Determination of Mn, Fe, Ni, Cu, Zn and Pb contents in samples of apple trees by radionuclide X-ray fluorescence analysis  

Energy Technology Data Exchange (ETDEWEB)

The applicability of the radionuclide X-ray fluorescence analysis (RXFA) for qualitative and quantitative evaluation of environmental plant samples is discussed and examples of determination of Mn, Fe, Ni, Cu, Zn, Pb in samples of apple trees are given. The instrumentation, the standard and sample preparation are also presented.

1982-12-01

413

Composting - environmentally compatible waste disposal - one of the incredients of waste management  

Energy Technology Data Exchange (ETDEWEB)

Considering the fact that more than 40% of all household wastes are organic wastes composting could be an excellent relief and complement to other waste disposal methods (e.g. combustion or direct landfills). Provided the right conditions household wastes could be composted together with sewage sludges and manures. The paper discusses the legal aspects, quantitative evaluations, conveying systems, as well as the compost utilization and marketing aspects valid for the Federal Republic of Germany.

1988-09-20

414

Comparative study of different methodologies for quantitative rock analysis by Laser-Induced Breakdown Spectroscopy in a simulated Martian atmosphere  

Energy Technology Data Exchange (ETDEWEB)

Laser-Induced Breakdown Spectroscopy was selected by NASA as part of the ChemCam instrument package for the Mars Science Laboratory rover to be launched in 2009. ChemCam's Laser-Induced Breakdown Spectroscopy instrument will ablate surface coatings from materials and measure the elemental composition of underlying rocks and soils at distances from 1 up to 10 m. The purpose of our studies is to develop an analytical methodology enabling identification and quantitative analysis of these geological materials in the context of the ChemCam's Laser-Induced Breakdown Spectroscopy instrument performance. The study presented here focuses on several terrestrial rock samples which were analyzed by Laser-Induced Breakdown Spectroscopy at an intermediate stand-off distance (3 m) and in an atmosphere similar to the Martian one (9 mbar CO{sub 2}). The experimental results highlight the matrix effects and the measurement inaccuracies due to the noise accumulated ...

2006-03-15

415

Comparative study of different methodologies for quantitative rock analysis by Laser-Induced Breakdown Spectroscopy in a simulated Martian atmosphere  

International Nuclear Information System (INIS)

Laser-Induced Breakdown Spectroscopy was selected by NASA as part of the ChemCam instrument package for the Mars Science Laboratory rover to be launched in 2009. ChemCam's Laser-Induced Breakdown Spectroscopy instrument will ablate surface coatings from materials and measure the elemental composition of underlying rocks and soils at distances from 1 up to 10 m. The purpose of our studies is to develop an analytical methodology enabling identification and quantitative analysis of these geological materials in the context of the ChemCam's Laser-Induced Breakdown Spectroscopy instrument performance. The study presented here focuses on several terrestrial rock samples which were analyzed by Laser-Induced Breakdown Spectroscopy at an intermediate stand-off distance (3 m) and in an atmosphere similar to the Martian one (9 mbar CO2). The experimental results highlight the matrix effects and the measurement inaccuracies due to the noise accumulated when low signals are ...

2006-03-01

416

Colorimetric porous indicator of carbon dioxide  

Energy Technology Data Exchange (ETDEWEB)

This paper investigates the spectral characteristics of three-dimensionally porous carbon dioxide indicators based on a porous silicate glass and phenolphthalein. The absorption spectra of the original solutions of phenolphthalein in alkaline and acid solutions are shown. The solutions were acidified by bubbling CO/sub 2/ through an alkaline phenolphthalein solution. The authors have succeeded in producing a reversible colorimetric adsorption indicator for carbon dioxide which after proper calibration enables the CO/sub 2/ content of an atmosphere to be estimated quantitatively.

1986-03-01

417

Bonus incensed | vox - Research-based policy analysis and commentary from leading economists  

Wastenet

... There is an evident, growing public discontent among supervisors and regulators with quantitative risk evaluation techniques, including Value-at-Risk and similar methods, so it is surprising to see the same authorities now advocating their use in more doubtful circumstances to risk weight bonuses. Deferrals and claw backs ...

418

Beyond "Little Taipei": The Development of Taiwanese Immigrant Businesses in Los Angeles.  

Science.gov (United States)

Qualitative and quantitative techniques, including a telephone survey of 310 Taiwanese business owners, were used to study the unique features of Taiwanese immigrant businesses in Los Angeles (California). When provided with entrepreneurial capital, Taiwanese enterprises grow rapidly in the context of Los Angeles's economic restructuring. (SLD)

1994-12-01

419

Beam position monitor sensitivity for low-[beta] beams  

Energy Technology Data Exchange (ETDEWEB)

Design of a beam position monitor (BPM) which is sensitive to low velo charged particle beams is considered. Quantitative estimates are made for the corrections to the conventional approximations to solutions of the Laplace Equation in two-dimensions when a BPM is used to measure to position of low velocity (low-[beta]) beams. (AIP)

1994-10-10

420

Assimilation of Remote Sensing Data into Shelf Sea Hydrodynamic Models  

Environmental Research Database

DescriptionRemote sensing of the sea surface from satellites in near-polar orbits has contributed greatly to our understanding of the links between physical and biological processes in marine systems. However most of this progress has been made in open oceanic waters or major upwelling areas, and many unresolved problems are encountered in coastal regions and shelf seas. In these optically complex waters, quantitative remote sensing requires a more sophisticated interpretation strategy than that implemente [continued...

421

Assessing the Risks of Sampling Rates for Surveilling a Population  

British Library Electronic Table of Contents (United Kingdom)

Surveillance of a population, such as a weapon stockpile, is needed to discover manufacturing defects as well as deterioration as the population ages. This article considers the risks of sampling rates for surveillance from three perspectives: detection probability of defects in a proportion of a population with pass/fail data, detection of a trend in a defective proportion of the population with pass/fail data, and detection of a trend with quantitative degradation measurements. Understanding of these risks will help the decision maker choose a sampling rate to protect against such problems of a specified size at a tolerable risk.

2011-01-01

422

Application of alpha and gamma spectroscopy to the quantitative analysis of transuranium nuclides in nuclear fuel  

International Nuclear Information System (INIS)

In nuclear fuel with a burn-up of 33 kg/t U and 52 kg/t U 15 transuranium nuclides "2"3"7Np to "2"4"6Cm have been determined by alpha and gamma spectroscopy after radiochemical separation. (author).

423

An intercomparison of computer assisted date processing and display methods in radioisotope scintigraphy using mathematical tumours  

International Nuclear Information System (INIS)

Several computer assisted processing and display methods are evaluated using a series of 100 normal brain scintigrams, 50 of which have had single 'mathematical tumours' superimposed. Using a standard rating system, or in some cases quantitative estimation, LROC curves are generated for each method and compared. (author).

424

A mechanism for the degradation of superconducting transition temperatures on high energy neutron irradiation in A-15 compounds  

International Nuclear Information System (INIS)

Electron microscopic observations of neutron irradiated Nb_3Sn revealed the presence of highly disordered regions of size approximately 35 A in a much less disordered matrix. This observation is shown to provide a means of explaining quantitatively many superconducting properties of irradiated A-15 compounds. In particular Tsub(c) of the irradiated materials could be easily predicted using the mathematical formulations developed for the proximity effect. (Auth.).

425

Time Management in Acute Vertebrobasilar Occlusion  

International Nuclear Information System (INIS)

Acute vertebrobasilar occlusion (VBO) is associated with a high risk of stroke and death. Although local thrombolysis may achieve recanalization and improve outcome, mortality is still between 35% and 75%. However, without recanalization the chance of a good outcome is extremely poor, with mortality rates of 80-90%. Early treatment is a fundamental factor, but detailed studies of the exact time management of the diagnostic and interventional workflow are still lacking. Data on 18 patients were retrospectively evaluated. Time periods between symptom onset, admission to hospital, time of diagnosis, and beginning of intervention were correlated with postinterventional neurological status. The Glasgow Coma Scale and National Institute of Health Stroke Scale (NIHSS) were used to examine patients before and after local thrombolysis. Additionally, multivariate statistics were applied to reveal similarities between patients with neurological improvement. Primary recanalization was achieved in ...

2009-03-01

426

Swimming exercise training prior to acute myocardial infarction attenuates left ventricular remodeling and improves left ventricular function in rats.  

Science.gov (United States)

The effect of exercise training prior to acute myocardial infarction (AMI) on left ventricular (LV) remodeling is poorly understood. This study investigated the protective effect of 3 weeks of swimming exercise training prior to AMI on cardiac morphology and function. Male Sprague-Dawley rats (n = 35) were randomly assigned to 3 groups: swimming training (n = 14, 90 min, 5 days/wk, 3 wk), sedentary (n =14), and controls (n = 7, no exercise, no MI). At the end of the training/sedentary period, rats were subjected to AMI (ExMI and SedMI) induced by surgical ligation of the left coronary artery. Thereafter, the rats remained sedentary for a 4-wk recovery period. Trans-thoracic echocardiography was performed in each group at the end of the exercise/sedentary period (pre-AMI), 24 hr after AMI, and following recovery (4 wk after AMI). No differences were observed in LV dimensions and function pre-AMI among the 3 groups; however, LV-end systolic diameter (LVESD) and ...

2005-01-01

427

Improved detection of myocardial infarction with technetium-99m stannous pyrophosphate and serum MB creatine phosphokinase  

International Nuclear Information System (INIS)

The relative sensitivity and combined value of myocardial technetium-99m stannous pyrophosphate imaging and determinations of serum MB creatine phosphokinase (the ''myocardial'' CPK isoenzyme) in detecting acute myocardial infarction were evaluated in 41 patients with suspected infarction and 23 patients recovering from cardiac surgery. In the patients with suspected infarction, myocardial infarction was confirmed in 25 and was consistently associated with increased serum MB CPK. Abnormal radionuclide images were obtained in 23 of 25 patients (92%)) with definite myocardial infarction and in 2 of 16 patients without confirmed infarction. Although the localization of infarction by imaging correlated well with the localization by electrocardiogram, infarct size estimated by imaging did not correlate well with estimates based on peak total serum CPK activity or serial changes in CPK activity. Serum MB CPK activity increased after cardiac surgery in 6 patients undergoing valve replacement ...

428

Diabetic patients have abnormal cerebral autoregulation during cardiopulmonary bypass  

Energy Technology Data Exchange (ETDEWEB)

We tested the hypothesis that insulin-dependent diabetic patients with coronary artery bypass graft surgery experience altered coupling of cerebral blood flow and oxygen consumption. In a study of 23 patients (11 diabetics and 12 age-matched controls), cerebral blood flow was measured using 133Xe clearance during nonpulsatile, alpha-stat blood gas managed cardiopulmonary bypass at the conditions of hypothermia and normothermia. In diabetic patients, the cerebral blood flow at 26.6 +/- 2.42 degrees C was 25.3 +/- 14.34 ml/100 g/min and at 36.9 +/- 0.58 degrees C it was 27.3 +/- 7.40 ml/100 g/min (p = NS). The control patients increased cerebral blood flow from 20.7 +/- 6.78 ml/100 g/min at 28.4 +/- 2.81 degrees C to 37.6 +/- 8.81 ml/100 g/min at 36.5 +/- 0.45 degrees C (p less than or equal to 0.005). The oxygen consumption was calculated from jugular bulb effluent and increased from hypothermic values of 0.52 +/- 0.20 ml/100 g/min in diabetics to 1.26 +/- 0.28 ...

1990-11-01

429

Cold pressor test myocardial perfusion SPECT as a predictor of the development of ischemia at exercise in the follow up of asymptomatic patients with moderate cardiovascular risk  

International Nuclear Information System (INIS)

Introduction: Previous studies have published the correlation between myocardial perfusion SPECT (MP) during cold pressor test (CPT) and intracoronary acetylcholine and its usefulness as independent marker of endothelial dysfunction (ED). Objective: To analyze the incidence of positivization of MP exercise studies in the follow up of asymptomatic patients with moderate cardiovascular risk (CV) and ED detected by PF. Material and Methods: Of 301 patients of the PARADIGMA Registry (normal exercise MP SPECT and clinical probability < 20% of events at 10 years [moderate risk by Framingham index]) 55 had positive PF (+) (18.3%). Prospectively and consecutively, 15 asymptomatic patients with PF (+), and a control group (CG) of 15 patients with negative PF, with paired sex, age and coronary risk factors (CRF), that accomplished a 12 #+-# 2 months follow up, and that underwent a new exercise and resting MP SPECT were analyzed. An MP extension score was used in a model ...

430

Treatment of peripheral aneurysms by dacron-covered nitinol stents; Behandlung arterieller Aneurysmen der Becken-Bein-Gefaesse mittels Dacron-ummantelter Nitinol-Stents  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate the success rates of the implantation of stent grafts in the treatment of peripheral aneurysms. Materials and methods: in 13 patients with 15 aneurysms at the common iliac artery (n = 6), external iliac artery (n = 1), hypogastric artery (n = 2), femoral artery (n = 2) or popliteal artery (n = 4), implantation of dacron-covered nitinol stents was performed. The patients were followed up for three to 20 months (mean, 8.8 months) with intravenous digital subtraction angiography, CT or colour-coded Doppler sonography. Results: In all cases, the aneurysm was successfully occluded after stent implantation. In one case with a popliteal aneurysm, kinking of the vessel caused thrombosis of the stent. The stent was successfully reopened. The aneurysm however, had to be surgically treated 9 months later. The primary and secondary patency rates at 6 months were 93% and 100%, respectively. Conclusion: The method described might be an alternative therapy to ...

1998-03-01

431

Liver trauma from penetrating injuries. Miscellanea, personal series, clinical and CT findings  

International Nuclear Information System (INIS)

Penetrating liver wounds are related to many causes and rank second after blunt abdominal and liver trauma. In this report are examined the clinical and radiological findings of personal series of patients with penetrating trauma, especially by firearms and stab and cut wounds. It will also tried to define the diagnostic workup of these traumas, which is especially based on CT signs of liver damage and associated changes and which is of basic importance for following treatment, both surgical or conservative. In the last seven years it was retrospectively reviewed 31 cases of penetrating liver trauma. The patients were 19 men and 12 women, ranging in age 18 to 73 (mean 42), with penetrating liver injuries from firearms (16 patients) and stab (9 cases) wounds; 6 patients had injuries from different cases. Abdominal CT was carried out in emergency with the CT Angiography (CTA) technique in all patients. In the patients with suspected chest and abdomen involvement CT ...

2000-12-01

432

Aortic non communicating dissections. A study with helical CT  

International Nuclear Information System (INIS)

The evaluate the signs of aortic intramural hematoma with helical CT and the diagnostic role of this technique in patients with this condition. It was reviewed the CT findings of 396 patients submitted to emergency examinations for suspected aortic dissection from 1995 to 1999. Only 18 patients (6 women and 12 men) had CT signs of aortic intramural hematoma. Helical CT studies were carried out with the following parameters: slice thickness 10 mm, reconstruction index 10, feed 1.5 mm, conventional algorithm with minimum values of 130 kV and 125mA. All patients were examined with dynamic contrast-enhanced CT, before and after a power injection of 130 mL ionic contrast material. It was studied: hematoma localization and longitudinal extension; thickness and density of aortic wall; presence and location of intimal calcifications; integrity of intimal wall; hemo mediastinum and/or hemo thorax. Aortic wall thickening appeared as a high density crescent-shaped area at baseline CT and had low ...

2000-09-01

433

The peak to background method in quantitative ion microprobe analysis of thick biological specimens  

Energy Technology Data Exchange (ETDEWEB)

The use of the ratio of the characteristic intensity to the continuum background intensity (P/B ratio) of the X-ray spectrum for a quantitative ion microprobe (IMP) or PIXE (particle induced X-ray emission) analysis of thin biological specimens was proposed previously. The IMP analysis of thick biological specimens is also of considerable practical use. In this paper, the possibility of using the P/B ratio to quantify minor elements in thick biological specimens is investigated. The epoxy resin based standards with gradual concentrations of KCNS up to 0.6 mol/kg and NBS bovine liver were analyzed by a 27 MeV {alpha} particle microprobe. The measured peak to background ratios (between 4.4 to 5.7 keV) agreed well with the theoretical calculations. The calculations showed that the concentration dependence of the P/B ratios was determined mainly by the absorption of X-rays in specimens. The results indicate that the P/B method is useful for IMP analysis of thick ...

1991-05-01

434

The energy supply for the new housing area `De Groote Wielen`, Den Bosch, Netherlands; De energievoorziening voor de nieuwbouwlocatie De Groote Wielen  

Energy Technology Data Exchange (ETDEWEB)

`De Groote Wielen` is going to be a newly built area of the municipality Den Bosch, Netherlands. In the period 1998-2011 circa 6,200 houses and 39,000 m{sup 2} will be built. Under the authority of the municipality Den Bosch CE compared a few energy supply options. Attention is paid to three different forms of energy supply: traditional supply of natural gas and electricity, supply of heat (produced by cogeneration gas engines and collective electrical heat pumps) and electricity, and supply of electricity by means of individual heat pumps for each house. Two levels of the energy performance standard are taken into account: 1.2 and 1.0. Also costs and resulting emissions of those options are compared. Next to a quantitative discussion, also the qualitative consequences of the three concepts are dealt with. The most important quantitative consequence concerns the flexibility of the energy supply for the future, in particular in the view of a ...

1996-07-01

435

The behavior of waste rock piles; Le comportement des haldes de steriles  

Energy Technology Data Exchange (ETDEWEB)

Under the auspices of the Mine Environment Neutral Drainage (MEND) Program, several waste rock piles were monitored and characterized. Acid rock drainage (ARD) became a mechanism better understood based on the data acquired during these projects. Numerical simulation was used to better comprehend the quantitative issues associated with the characterization of three specific sites for the purpose of this study. The sites selected were the south waste rock pile of the Doyon Mine in Quebec, the Northdale of the mining district of Ronnenberg in Germany, and the waste rock pile of the Sugar Shack South of the Questa mine in New Mexico. The observed and simulated conditions were very distinct from one mine to another, even if the same mechanisms were involved. The dominant oxygen and heat transfer mechanisms displayed the most varied behavior between the sites. ARD control or site rehabilitation decisions were based on the quantitative understanding ...

2000-07-01

436

Technical note: A physical phantom for assessment of accuracy of deformable alignment algorithms  

International Nuclear Information System (INIS)

The purpose of this study was to investigate the feasibility of a simple deformable phantom as a QA tool for testing and validation of deformable image registration algorithms. A diagnostic thoracic imaging phantom with a deformable foam insert was used in this study. Small plastic markers were distributed through the foam to create a lattice with a measurable deformation as the ground truth data for all comparisons. The foam was compressed in the superior-inferior direction using a one-dimensional drive stage pushing a flat 'diaphragm' to create deformations similar to those from inhale and exhale states. Images were acquired at different compressions of the foam and the location of every marker was manually identified on each image volume to establish a known deformation field with a known accuracy. The markers were removed digitally from corresponding images prior to registration. Different image registration algorithms were tested using this method. Repeat measurement of marker ...

2007-07-01

437

SIMS and XRD measurements for the critical review of carbon diffusivity derivation from hardness profiles  

Energy Technology Data Exchange (ETDEWEB)

Microhardness decarburization profiles are often used in the industry to estimate the carbon distribution in steels. For quantitative evaluation, an analysis based on diffusion theory must be performed, the fundamentals and mathematical basics of which are presented. If the relationship between hardness and carbon content is known, microhardness-distance curves of steels can be analyzed in this way. For martensitic grades, for instance, a linearized expression holds in the concentration range from 0.15 to 0.6 m.% C. Microhardness depth profiles of higher carbon steels and other microstructures, however, are also evaluated in the literature. The applicability of quantitative diffusion modeling is discussed in detail. Through hardenable rolling bearing steel 100Cr6 (1.3505, SAE 52100) serves as model material: carbon concentration-distance curves are measured with high accuracy by secondary ion mass spectrometry (SIMS) and compared with ...

2007-07-01

438

Repeated quantitative bone scintigraphy in patients with prostatic carcinoma treated with orchiectomy  

Energy Technology Data Exchange (ETDEWEB)

Bone scintigraphy was performed in 16 men with newly diagnosed prostatic carcinoma before orchiectomy as well as 2 weeks and 2 months after operation. The uptake in the lower thoracic and lumbar vertebrae was registered up to 240 min after injection of /sup 99m/Tc-MDP and was then calculated for each patient and vertebra. The relative standard deviation in measured uptake due to measuring technique was estimated to be +-7%. In eight patients, who had normal bone scintigraphies before orchiectomy, there were no changes in the uptake values after operation. The remaining eight patients had widespread metastatic involvement prior to treatment, six of these patients showed a so-called 'flare phenomenon' in the abnormal vertebrae which means an initial increase in uptake after operation followed by a decreased uptake in response to therapy. One patient had a continuously increased uptake in all the abnormal vertebrae which correlated well with the clinical progression of ...

1988-07-01

439

Repeated quantitative bone scintigraphy in patients with prostatic carcinoma treated with orchiectomy  

International Nuclear Information System (INIS)

Bone scintigraphy was performed in 16 men with newly diagnosed prostatic carcinoma before orchiectomy as well as 2 weeks and 2 months after operation. The uptake in the lower thoracic and lumbar vertebrae was registered up to 240 min after injection of "9"9"mTc-MDP and was then calculated for each patient and vertebra. The relative standard deviation in measured uptake due to measuring technique was estimated to be #+-#7%. In eight patients, who had normal bone scintigraphies before orchiectomy, there were no changes in the uptake values after operation. The remaining eight patients had widespread metastatic involvement prior to treatment, six of these patients showed a so-called 'flare phenomenon' in the abnormal vertebrae which means an initial increase in uptake after operation followed by a decreased uptake in response to therapy. One patient had a continuously increased uptake in all the abnormal vertebrae which correlated well with the clinical progression of the disease, while ...

440

Quantitative monitoring of the fluorination process by neutron counting  

Energy Technology Data Exchange (ETDEWEB)

Plutonium metal is produced by reducing PuF{sub 4} prepared from PuO{sub 2} by fluorination. Both fluorination and reduction are batch processes at the Los Alamos Plutonium Facility. The conversion of plutonium oxide to fluoride greatly increases the neutron yield, a result of the high cross section for alpha-neutron ({alpha},n) reactions on fluorine targets compared to the (more than 100 times) smaller {alpha},n yield on oxygen targets. Because of the increase, total neutron counting can be used to monitor the conversion process. This monitoring ability can lead to an improved metal product, reduced scrap for recycle, waste reduction, minimized reagent usage, and reduce personnel radiation exposures. A new stirred-bed fluorination process has been developed simultaneously with a recent evaluation of an automated neutron-counting instrument for quantitative process monitoring. Neutrons are counted with polyethylene-moderated {sup 3}He-gas proportional counters. ...

1993-12-31

441

Quantitative evaluation of bile diversion surgery utilizing /sup 99m/Tc HIDA scintigraphy  

Energy Technology Data Exchange (ETDEWEB)

This is a report of 21 patients presenting with epigastric pain, bilious vomiting, upper gastrointestinal bleeding, iron-deficiency anemia, and weight loss, who had undergone Billroth II gastrectomy from 3 to 35 yr earlier. Eighteen of 21 patients were found to have significant enterogastric reflux indices varying from 60% to 95% demonstrated by /sup 99m/Tc HIDA scintigraphy. Thirteen patients had diversion antireflux surgery in the form of a Roux-en-Y procedure, and 1 patient had a Henley loop jejunal interposition. Postoperative /sup 99m/Tc HIDA scintigraphic studies showed the enterogastric reflux indices to have decreased significantly to a range of 2%-26% (p less than 0.00001). There was marked improvement of symptoms, including correction of anemia and weight gain in those patients who had been anemic or who had sustained earlier weight loss. The enterogastric reflux indices of 10 asymptomatic control patients after Billroth II gastrectomy ranged from 4% to 45%. /sup 99m/Tc HIDA ...

1983-02-01

442

Quantitative bone scintigraphy in prostatic carcinoma - long-term response to treatment  

Energy Technology Data Exchange (ETDEWEB)

Quantitative bone scintigraphy was performed in 24 patients with prostatic carcinoma before orchiectomy and up to one to four years after operation. The gamma camera count rate was recorded over the lower thoracic and all lumbar vertebrae 4 h after injection of [sup 99m]Tc-MDP. Twelve patients has normal bone scintigrams throughout the study. They showed from two years after operation a slight increase in count rate values compared with the preoperative values, probability due to hormonal changes after orchiectomy and to age-related alterations in skeletal metabolism. Twelve patients had abnormal bone scintigrams. They showed as a response to treatment the flare phenomenon with an increase in count rate over the abnormal vertebrae when measured two weeks after operation followed by a decrease after two months. The lowest count rate values were obtained between six months and one year after operation. Thereafter the count rate seemed to remain on the same level. An ...

1993-10-01

443

Quantitative bone scintigraphy in prostatic carcinoma - long-term response to treatment  

International Nuclear Information System (INIS)

Quantitative bone scintigraphy was performed in 24 patients with prostatic carcinoma before orchiectomy and up to one to four years after operation. The gamma camera count rate was recorded over the lower thoracic and all lumbar vertebrae 4 h after injection of "9"9"mTc-MDP. Twelve patients has normal bone scintigrams throughout the study. They showed from two years after operation a slight increase in count rate values compared with the preoperative values, probability due to hormonal changes after orchiectomy and to age-related alterations in skeletal metabolism. Twelve patients had abnormal bone scintigrams. They showed as a response to treatment the flare phenomenon with an increase in count rate over the abnormal vertebrae when measured two weeks after operation followed by a decrease after two months. The lowest count rate values were obtained between six months and one year after operation. Thereafter the count rate seemed to remain on the same level. An ...

444

Quantitative assessment of mineral content in metacarpal bone with Fuji computed radiography  

Energy Technology Data Exchange (ETDEWEB)

A new microdensitometry method for quantitative assessment of bone mineral content using Fuji computed radiography (FCR) was developed and the results were compared with those obtained by the conventional film-screen method. Using both methods, X-ray pictures of the 2nd metacarpal bone were taken with a reference aluminum step wedge in nine normal subjects and nine parameters representing the width and density of bone marrow and cortex were calculated in middle of the bone shaft. Interobserver reproducibility assessed for three parameters was significantly higher in the FCR method than the conventional one. The value of {Sigma}GS computed by the FCR method, that is equivalent to the net bone density of the transverse section of the shaft, showed higher correlation with the one obtained by computed tomography in comparison with the conventional method. In our FCR method, moreover, interobserver reproducibility and accuracy was improved by employing automatic ...

1990-05-01

445

Quantitative assessment of mineral content in metacarpal bone with Fuji computed radiography  

International Nuclear Information System (INIS)

A new microdensitometry method for quantitative assessment of bone mineral content using Fuji computed radiography (FCR) was developed and the results were compared with those obtained by the conventional film-screen method. Using both methods, X-ray pictures of the 2nd metacarpal bone were taken with a reference aluminum step wedge in nine normal subjects and nine parameters representing the width and density of bone marrow and cortex were calculated in middle of the bone shaft. Interobserver reproducibility assessed for three parameters was significantly higher in the FCR method than the conventional one. The value of #SIGMA#GS computed by the FCR method, that is equivalent to the net bone density of the transverse section of the shaft, showed higher correlation with the one obtained by computed tomography in comparison with the conventional method. In our FCR method, moreover, interobserver reproducibility and accuracy was improved by employing automatic ...

1990-01-01

446

Quantitative assessment of cancer risk from exposure to diesel engine emissions  

Energy Technology Data Exchange (ETDEWEB)

Quantitative estimates of lung cancer risk from exposure to diesel engine emissions were developed using data from three chronic bioassays with Fischer 344 rats. Human target organ dose was estimated with the aid of a comprehensive dosimetry model. This model accounted for rat-human differences in deposition efficiency, normal particle clearance rates, transport of particles to lung-associated lymph nodes, respiration rates, and lung surface area, as well as high-dose inhibition of particle clearance. Recent evidence indicates that the inert carbon core of the diesel particulate matter is likely to be the primary source of carcinogenicity. The epithelial tissue lining the alveoli and lower airways is the primary target site for induction of lung tumors. Dose was therefore based upon the concentration of carbon particulate matter per unit lung surface area. Unit risk estimates were developed using either a time-to-tumor or a linearized multistage model. The unit ...

1993-02-01

447

Quantitative assessment of bone scintigraphy in the hip joint disease  

International Nuclear Information System (INIS)

Quantitative assessment of bone scintigraphy was performed in fifty-six patients with hip joint disease including femoral neck fracture, aseptic necrosis of the femoral head, traumatic dislocation of the hip, Perthes disease, and transient synovitis of the hip. In the static study, bone scintigraphy was obtained 3 hours after injection of sup(99m)Tc-MDP by gamma camera equipped with a computer and uptake ratios were calculated. In the dynamic study, bone scintigraphy was performed in one, 3 and 5 hours after injection of radionuclide. Femoral head uptake ratio was markedly decreased in osteonecrosis following femoral neck fracture and characteristically increased in aseptic necrosis of the femoral head but prolonged retention of sup(99m)Tc-MDP could be observed. Uptake ratios of epiphysis were decreased in Perthes disease but normal in transient synovitis of the hip. Static and dynamic study of bone scintigraphy may be useful for early diagnosis and treatment in ...

448

Quantitation of acyl migration during lipase-catalyzed acidolysis, and of the regioisomers of structured triacylglycerols formed  

DEFF Research Database (Denmark)

Various MLM-type (M, medium-chain fatty acids; L, long-chain fatty acids) structured triacylglycerols were produced in pilot- or small-scale packed-bed reactors by lipase-catalyzed acidolysis. The incorporation and acyl migration of octanoic acid were measured by gas chromatography and Grignard degradation, and ranged from 39.0 to 48.7% and 0.6 to 9.3%, respectively. Quantitation of triacylglycerol molecular species was performed by ammonia negative ion chemical ionization (NICI) mass spectrometry (MS). The proportion of ACN (acyl carbon number) 34 species that contained one C-18 fatty acid and two C-8:0, in samples analyzed, varied from 12.5 to 23.2%. The selected regioisomers MLM and MML within the ACN 34 species group were quantified by NICI tandem MS (MS/MS) and were in the range of 97.1 to 98.4% and 1.6 to 2.9%, respectively. There was no correlation between the level of acyl migration during lipase-catalyzed esterification and the level of regioisomers of the ...

2001-01-01

449

Post-column reaction detector for platinum(II) antieoplastic agents  

Energy Technology Data Exchange (ETDEWEB)

The development and evaluation of a post-column reaction detector sensitive to platinum(II) complexes is presented in which sodium bisulfite is used as the derivatizing agent with potassium dichromate as an activating agent. The influences of mobile phase changes (i.e., pH, organic modifiers, electrolytes), oxygen, metal ions, and order of reagent addition on reaction kinetics and product yield are defined and used in optimization of detector response. Detection at lambda/sub max/ 290 nm results in an on-line post-column sensitivity of 40-60 ng/mL for selected cis-dichloroplatinum complexes and a sensitivity of 300-1200 ng/mL for four (substituted)-malonato-platinum complexes. The reaction detector is used to monitor the kinetics of aquation of cisplatin (CDDP) and to quantitate CDDP degradation in plasma. As the sensitivity for CDDP in plasma is comparable to that achieved from high pressure liquid chromatography (HPLC) effluent fractionation/off-line flameless ...

1984-03-01

450

Microstructural Coarsening during Thermomechanical Fatigue and Annealing of Micro Flip-Chip Solder Joints  

Energy Technology Data Exchange (ETDEWEB)

Microstructural evolution due to thermal effects was studied in micro solder joints (55 {+-} 5 {micro}m). The composition of the Sn/Pb solder studied was found to be hypereutectic with a tin content of 65--70 wt%.This was determined by Energy Dispersive X-ray analysis and confirmed with quantitative stereology. The quantitative stereological value of the surface-to-volume ratio was used to characterize and compare the coarsening during thermal cycling from 0--160 C to the coarsening during annealing at 160 C. The initial coarsening of the annealed samples was more rapid than the cycled samples, but tapered off as time to the one-half as expected. Because the substrates to which the solder was bonded have different thermal expansion coefficients, the cycled samples experienced a mechanical strain with thermal cycling. The low-strain cycled samples had a 2.8% strain imposed on the solder and failed by 1,000 cycles, despite undergoing less ...

1998-12-01

451

Mapping quantitative trait loci controlling milk production in dairy cattle by exploiting progeny testing  

Energy Technology Data Exchange (ETDEWEB)

We have exploited {open_quotes}progeny testing{close_quotes} to map quantitative trait loci (QTL) underlying the genetic variation of milk production in a selected dairy cattle population. A total of 1,518 sires, with progeny tests based on the milking performances of >150,000 daughters jointly, was genotyped for 159 autosomal microsatellites bracketing 1645 centimorgan or approximately two thirds of the bovine genome. Using a maximum likelihood multilocus linkage analysis accounting for variance heterogeneity of the phenotypes, we identified five chromosomes giving very strong evidence (LOD score {ge} 3) for the presence of a QTL controlling milk production: chromosomes 1, 6, 9, 10 and 20. These findings demonstrate that loci with considerable effects on milk production are still segregating in highly selected populations and pave the way toward marker-assisted selection in dairy cattle breeding. 44 refs., 4 figs., 3 tabs.

1995-02-01

452

Mapping of quantitative trait loci (QTL) for production, resistance and tolerance traits in Salix. Final Report  

Energy Technology Data Exchange (ETDEWEB)

Quantitative trait loci (QTL) for growth traits, water use efficiency and tolerance/resistance against metals and herbivores have been identified. A hybrid F2 population originating from a cross between a Salix dasyclados-clone (SW901290) and a S. viminalis-clone ('Jorunn') was used for the different studies in this project. The growth response was analyzed in a greenhouse experiment with two water treatments, normal and drought. In addition, three field experiments with contrasting soils and climates were established. QTL specific for each treatment or field environment but also QTL stable over the treatments or field environments were detected. Each QTL explained from 8 to 29 % of the phenotypic variation depending on trait, treatment or field environment. Clusters of QTL for different traits were mapped indicating a common genetic base or tightly-linked QTL. Stable QTL identified for dryweight can be useful tools for early selection in Salix. ...

2004-05-01

453

How to overestimate risks of ionizing radiations  

International Nuclear Information System (INIS)

Ignoring the numerous, known and mainly unknown, interactions between chemicals and ionizing radiations, causes strong controversy about the risks of ionizing radiations. Yet the best known interactions between chemicals and radiations is that between radon and tobacco smoke. Although it is and it will be always impossible to derive quite quantitative laws for this interaction, it has been possible to derive some semi-quantitative relationships based on reasonable assumptions and statistics on lung cancer deaths in developed countries. They show that ignoring the dangers of tobacco smoking as we did still long after we had recognised the dangers of radiations, could asses to radiations thirty or forty times more risks than reality. As present world is flown by tens of thousands chemicals, little or not present in a natural environment, and as it would be very surprising that some hundreds of these do not behave like those contained in tobacco ...

454

How citation boosts promote scientific paradigm shifts and Nobel Prizes  

CERN Document Server

Nobel Prizes are commonly seen to be among the most prestigious achievements of our times. Based on mining several million citations, we quantitatively analyze the processes driving paradigm shifts in science. We find that groundbreaking discoveries of Nobel Prize Laureates and other famous scientists are not only acknowledged by many citations of their landmark papers. Surprisingly, they also boost the citation rates of their previous publications. Given that innovations must outcompete the rich-gets-richer effect for scientific citations, it turns out that they can make their way only through citation cascades. A quantitative analysis reveals how and why they happen. Science appears to behave like a self-organized critical system, in which citation cascades of all sizes occur, from continuous scientific progress all the way up to scientific revolutions, which change the way we see our world. Measuring the "boosting effect" of landmark papers, ...

2011-01-01

455

Dynamic quantitative bone scintigraphy in patients with prostatic carcinoma treated by orchiectomy  

International Nuclear Information System (INIS)

Dynamic quantitative bone scintigraphy was performed on 31 men with prostatic carcinoma before orchiectomy as well as 2 weeks, 2 and 6 months postoperatively. After injection of technetium methylene diphosphonate Tc 99m ("9"9"mTc-MDP) the count rate was recorded as serial images over the lower thoracic and all the lumbar vertebrae from 1 to 240 min post-injection. Thirteen men had normal bone scintigrams with no changes in "9"9"mTc-MDP content at the four different investigation times. Eighteen men had skeletal metastases. Throughout the study half of the abnormal vertebrae in these patients showed an abnormal count rate after only 6 min post-injection. After 1 h it was possible in almost all abnormal vertebrae to predict abnormal bone uptake. In response to therapy a 'flare phenomenon' with an increase in count rate was seen 2 weeks after orchiectomy followed by a decrease 2 months postoperatively in most of the abnormal vertebrae. The count rate decreased even ...

456

Diagnosis of breast cancer with MR imaging using the magnetization transfer contrast and a newly-developed breast surface coil for the supine position  

Energy Technology Data Exchange (ETDEWEB)

We developed a new breast surface coil for the supine position. The subjects consisted of 9 patients with breast cancer varying from 46 to 60 years of age (average: 52). The cancer image of the SPGR (CE+) method was compared with that of the FSMTC (MTC-SPGR (CE+)) method and that of the FSMTC (MTC-SPGR with fat-saturation (CE+)) method in the sagittal section after injection of Gd-DTPA (0.1 mmol/kg). Quantitative analyses were performed before and after injection of Gd-DTPA in 6 patients. Three patients were excluded from the quantitative analyses owing to the clear detection of tumors in the fat tissue. Signal intensity measurements were systematically performed in each region of interest (ROI), i.e. the cancer lesion, the surrounding mammary gland. Statistical analyses showed significant differences between the lesions using the FSMTC (MTC-SPGR (CE+)), and the FSMTC (MTC-SPGR with fat-saturation (CE+)) methods and the lesions using the SPGR ...

1998-09-01

457

Determination of microsomal lauric acid hydroxylase activity by HPLC with flow-through radiochemical quantitation  

International Nuclear Information System (INIS)

An assay for the microsomal hydroxylation of lauric acid (LA), based on HPLC with flow-through radiochemical detection, has been developed. Conditions were optimized for resolution and quantitation of three microsomal metabolites of "1"4C-LA, one of which has not been reported previously as a metabolite of LA in mammalian microsomal incubations. These products, 12-(omega)-hydroxy-LA, 11-(omega-1)-hydroxy-LA, and a novel metabolite, 10-(omega-2)-hydroxy-LA, were isolated by HPLC and identified by gas chromatography/mass spectrometry. In the presence of NADPH, the formation of all three metabolites was linear with time and microsomal protein concentration. Hydrogen peroxide also supported the microsomal metabolism of LA, although the ratio of metabolites was substantially different than that produced by NADPH-supported microsomes. Several biochemical probes (metyrapone, #alpha#-naphthoflavone, 2-diethylaminoethyl-2,2-diphenylvalerate hydrochloride, and 10-undecynoic ...

458

Depth profile analysis on the nanometer scale by a combination of electron probe microanalysis (EPMA) and focused ion beam specimen preparation (FIB)  

International Nuclear Information System (INIS)

Electron probe microanalysis (EPMA) offers high sensitivity and high accuracy in quantitative measurements of chemical compositions and mass coverages. Owing to the low detection limits of the wavelength-dispersive technique, monolayers with mass coverages of about 0.05 pg cm z can be detected. Assuming a density of 5 g cm--3 this corresponds to a thickness of 0.1 nm. With these advantages in mind, EPMA was extended to depth profile analysis in the sub-micron range using a surface removal technique. The present paper shows how depth profile analysis can be improved by combining EPMA and the focused ion beam (FIB) technique. The focused ion beam system uses a Ga+ ion beam. The ion beam allows the milling of defined geometries on the nanometer scale, so that very shallow bevels with exactly defined angles in relation to the surface can be obtained. Low surface damage is expected due to low sputtering effects. Calibrated WDX measurements along the bevel deliver ...

459

Confirmation of quantitative trait loci for resistance to multiple-HG types of soybean cyst nematode (Heterodera glycines Ichinohe)  

British Library Electronic Table of Contents (United Kingdom)

Genetic analysis of resistance of plant introduction (PI) 438489B to soybean cyst nematode (SCN) have shown that this PI is highly resistant to many SCN HG types. However, validation of the previously detected quantitative trait loci (QTL) has not been done. In this study, 250 F2:3 progeny of a Magellan (susceptible)??PI 438489B (resistant) cross were used for primary genetic mapping to detect putative QTL for resistance to five SCN HG types. QTL confirmation study was subsequently conducted using F6:7 recombinant inbred lines (RILs) derived from the same cross. Simple sequence repeat (SSR) and single nucleotide polymorphism (SNP) markers were employed for molecular genotyping. Interval mapping (IM), permutation tests, cofactor selection, and composite interval mapping (CIM) were performe...

2011-01-01

460

Comparison between NIR, MIR, concatenated NIR and MIR analysis and hierarchical PLS model. Application to virgin olive oil analysis.  

Science.gov (United States)

This work investigates the potential use of simultaneously near-infrared (NIR) and mid-infrared (MIR) spectroscopies for the quantitative analysis of fatty acids and triacylglycerols and for identifying the Registered Designation of Origin (RDO) of extra virgin olive oils. The two spectral ranges were used separately using PLS and PLS-DA regressions. To combine both information, concatenated matrix was used at the first time, multiblock method using H-PLS models were constructed at the second time. The models were compared in terms of prediction errors. The results obtained with MIR spectroscopy are better than the ones obtained with NIR spectroscopy. The H-PLS methodology seems to be very interesting for quantitative analysis with the use of additional information in the NIR range, which is not present in the MIR one. For RDO identification by discriminant analysis, the use of multiblock method was less efficient. PMID:20433960

2010-03-29

461

Climate Change, a Case Study of Media Construction of Environmental Problems; El Cambio Climatico como Casuistica de la Construccion Mediatica de los Problemas Medioambientales  

Energy Technology Data Exchange (ETDEWEB)

Nowadays climate change is one of the environmental problems in the global policy agenda. However, in countries like United States and United Kingdom the media started to report regularly on this issue in 1988. Since then many researches have been carrying out focused on how the media influence, along with other factors, public understanding of climate change through the media construction of the problem in several countries. Given the implications of social acceptance for design and implementation of public policies on mitigation and adaptation to climate change, the overall aim of this report is to review the status of the issue from a qualitative and quantitative approach. Qualitatively, media construction of climate change is described as the result of different processes taking place at macro and micro scales. Interactions among scientists, politicians, industry, the media themselves and the social context are considered macro-scale influences, while ...

2009-07-21

462

Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the art  

Energy Technology Data Exchange (ETDEWEB)

The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal equilibrium, homogeneous ...

2010-01-15

463

Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the art  

International Nuclear Information System (INIS)

The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal equilibrium, homogeneous ...

2010-01-01

464

Brain development during the first year of life. Quantitative assessment with ADC imaging  

International Nuclear Information System (INIS)

Brain development during the first year of life was assessed quantitatively using apparent diffusion coefficient (ADC) images constructed from diffusion-weighted MR image data. The imaging plane was coronal at the section of the pons. The cerebral peduncle, internal capsule, corona radiata, superior longitudinal fasciculus and thalamus were selected for evaluation of their ADC values. A diffusion sensitive gradient was added in the anteroposterior direction. Thus the orientation of nerve fibers in the cerebral peduncle, internal capsule and corona radiata was perpendicular to it, and that in the superior longitudinal fasciculus was parallel to it. In neonates, the cerebral peduncle and internal capsule, having been moderately myelinated at birth, showed the slowest diffusion. The corona radiata and superior longitudinal fasciculus, having been unmyelinated at birth, showed the fastest diffusion. The thalamus had intermediate diffusion. These neonatal diffusions ...

465

Bone scintigraphy in fluoride treated osteoporosis  

Energy Technology Data Exchange (ETDEWEB)

Quantitative bone scintigraphy was performed on 23 white females with post-menopausal osteoporosis and vertebral compression fractures. These patients were then entered into a randomized, double-blind clinical trial or sodium fluoride therapy (NaF=14, placebo=9) which included repeat bone scintigraphy every six months. Scintigraphic images were acquired for 500K counts per image over the total body with computer acquisition over the posterior thoracic and lumbar spine. Images were obtained on a wide field-of-view gamma camera two hours after injecting 15 mCi of Tc-99m MDP. Data analysis showed a significant reduction in the activity ratio of abnormal vertebral body to normal vertebral body in those patients treated with sodium fluoride (paired t-test p=0.0095). No significant change was observed in the control group of (p=0.142). These results suggest that sodium fluoride therapy promotes more rapid healing of osteoporotic vertebral fractures. They also demonstrate ...

1985-05-01

466

Atomistic Simulation of Water Percolation and Proton Hopping in Nafion Fuel Cell Membrane  

Energy Technology Data Exchange (ETDEWEB)

We have performed a detailed analysis of water clustering and percolation in hydrated Nafion configurations generated by classical molecular dynamics simulations. Our results show that at low hydration levels H2O molecules are isolated and a continuous hydrogen-bonded network forms as the hydration level is increased. Our quantitative analysis has established a hydration level (?) between 5 and 6 H2O/SO3- as the percolation threshold of Nafion. We have also examined the effect of such a network on proton transport by studying the structural diffusion of protons using the quantum hopping molecular dynamics method. The mean residence time of the proton on a water molecule decreases by two orders of magnitude when the ? value is increased from 5 to 15. The proton diffusion coefficient in Nafion at a ? value of 15 is about 1.1x10-5 cm2/s in agreement with experiment. The results provide quantitative atomic-level evidence of water network ...

2010-11-04

467

Assessment of the effects of pixel loss on image quality in direct digital radiography  

Energy Technology Data Exchange (ETDEWEB)

Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. Measurement of the MTF, ...

2004-03-21

468

Assessment of the effects of pixel loss on image quality in direct digital radiography  

International Nuclear Information System (INIS)

Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. Measurement of the MTF, NPS and DQE can reveal small changes ...

2004-03-21

469

Application of quantitative sedimentology in the characterization of subsurface reservoirs and outcrop analogs  

Energy Technology Data Exchange (ETDEWEB)

The thesis deals with methods of describing the reservoir rock in central oil and gas fields on the Norwegian continental shelf. Methods of enhancing the level of recovery are dealt with. Following topics are given: Sand body dimensions and infill sequences of stable, humid-climate delta plain channels; minipermeameter-based study of permeability trends in channel sand bodies; significance of tidal cyclicity for modelling of reservoir heterogeneities in the lower Jurassic Tilje Formation, mid-Norwegian shelf; geometry and facies of large-scale flow units in fluvial-dominated fan-delta-front sequences; quantified fluvial architecture in ephemeral stream deposits of the Esplugafreda Formation (Palaeocene), Tremp-Graus Basin, northern Spain; the Safari project - collection and storage of field analogue data for quantitative reservoir modelling; sedimentary architecture of field analogues for reservoir information (SAFARI): a case study of the fluvial Escanilla ...

1994-12-31

470

Analysis of the quantitative structure activity relationship of technetium-99m-labeled diaminedithiol (DADT) and propyleneamineoxime (PAO) brain blood flow analogues  

Energy Technology Data Exchange (ETDEWEB)

In the search for new brain imaging agents for use with single photon emission computed tomography (SPECT), quantitative structure activity relationship (QSAR) analysis of the correlations between initial brain uptake and physicochemical parameters like lipophilicity, log P, molecular weight, log MW and log U/D (undissociated/dissociated), of the {sup 99m}Tc-DADT (diaminedithiol) complexes and {sup 99m}Tc-PAO (propyleneaminoxime) complexes have been analyzed. High correlations are found for both the {sup 99m}Tc-DADT complexes (r = 0.94) and for the {sup 99m}Tc-PAO complexes (r = 0.83) which are significant at 99.9 and 99.5 percentile level, respectively. These results will help the further design of better ligands for {sup 99m}Tc in brain imaging. (author).

1991-01-01

471

An immunochemical approach to the study of DNA damage and repair. Technical progress report, May 1, 1989--April 30, 1992  

Energy Technology Data Exchange (ETDEWEB)

The overall objective of this project has been to develop immunochemical methods to quantitate unique DNA base damages in order to facilitate studies on radiation-induced damage production and repair. Specifically, we have been using antibodies raised to damaged bases to quantitate unique lesions in model systems in order to evaluate their potential biological consequences. Our approach has been to synthesize modified nucleotides or nucleosides, conjugate them to protein carriers, and use the conjugates as immunogens in rabbits or to prepare monoclonal antibodies. We have been studying damages that are stable radiolysis products found in X-irradiated DNA and thus of potential biological consequence. Our aim is to build an in vitro and in vivo data base on the interactions between model DNA lesions and such cellular enzymes as DNA polymerases and repair endonucleases. Initial studies have focused on pyrimidine ring saturation products (thymine ...

1992-05-01

472

An immunochemical approach to the study of DNA damage and repair  

Energy Technology Data Exchange (ETDEWEB)

The overall objective of this project has been to develop immunochemical methods to quantitate unique DNA base damages in order to facilitate studies on radiation-induced damage production and repair. Specifically, we have been using antibodies raised to damaged bases to quantitate unique lesions in model systems in order to evaluate their potential biological consequences. Our approach has been to synthesize modified nucleotides or nucleosides, conjugate them to protein carriers, and use the conjugates as immunogens in rabbits or to prepare monoclonal antibodies. We have been studying damages that are stable radiolysis products found in X-irradiated DNA and thus of potential biological consequence. Our aim is to build an in vitro and in vivo data base on the interactions between model DNA lesions and such cellular enzymes as DNA polymerases and repair endonucleases. Initial studies have focused on pyrimidine ring saturation products (thymine ...

1992-05-01

473

Additional information from quantitative 24-hour sup 99m Tc-MDP bone scintigraphy in patients with prostatic carcinoma  

Energy Technology Data Exchange (ETDEWEB)

Quantitative bone scintigraphy was performed at 4 and 24 h after injection of {sup 99m}Tc-MDP. The lower thoracic and all the lumbar vertebrae were recorded in 37 patients with prostatic carcinoma before orchiectomy as well as two weeks, two and six months postoperatively. Fourteen patients had normal bone scintigrams. By means of the measured variation in the count rate between normal vertebrae, the criterion for a vertebra to be considered as abnormal was determined using the 4 h-uptake values. For patients with normal scintigrams the count rate at 24 h was below the 4 h level and the mean 24 h/4 h ratio was determined to be 0.85 {+-} 0.09 (1 SD). Normal vertebrae in patients with skeletal metastases had only slightly lower count rate values at 24 h than at 4 h. Abnormal vertebrae showed a higher count rate at 24 h, especially two weeks postoperatively, while a tendency towards lower values than at 4 h was seen after 6 months. If the 24 h/4 h ratio is used as an ...

1991-01-01

474

Additional information from quantitative 24-hour "9"9"mTc-MDP bone scintigraphy in patients with prostatic carcinoma  

International Nuclear Information System (INIS)

Quantitative bone scintigraphy was performed at 4 and 24 h after injection of "9"9"mTc-MDP. The lower thoracic and all the lumbar vertebrae were recorded in 37 patients with prostatic carcinoma before orchiectomy as well as two weeks, two and six months postoperatively. Fourteen patients had normal bone scintigrams. By means of the measured variation in the count rate between normal vertebrae, the criterion for a vertebra to be considered as abnormal was determined using the 4 h-uptake values. For patients with normal scintigrams the count rate at 24 h was below the 4 h level and the mean 24 h/4 h ratio was determined to be 0.85 #+-# 0.09 (1 SD). Normal vertebrae in patients with skeletal metastases had only slightly lower count rate values at 24 h than at 4 h. Abnormal vertebrae showed a higher count rate at 24 h, especially two weeks postoperatively, while a tendency towards lower values than at 4 h was seen after 6 months. If the 24 h/4 h ratio is used as an ...

475

A quantitative structural analysis of the low temperature phase of lithium-7  

International Nuclear Information System (INIS)

Calculations in "7Li have been carried out for the differential coherent elastic scattering cross-section of thermal neutrons at a fixed scattering angle #theta#_0(148"o) and varying the energy of incident neutrons (or corresponding d-spacings). The results are reported, as variations of the ratio #SIGMA#_0"c"o"h (#theta#_0, d)/#SIGMA#_0"c"o"h (#theta#_0) with d-spacing, at atmospheric pressure and at two temperatures, 80 and 20 K. The calculations at 80 K correspond to BCC lithium whereas at 20 K all the possible crystallographic structures of polytype lithium (BCC, 9R, HCP and FCC) were considered. On comparing our results with the time-of-flight (TOF) measurements of Berliner et al. (Physical Review, B40, 12086, 1989) we find that up to 80 K lithium-7 does not undergo any martenistic transformation whereas the structural state at 20 K can be described by the co-existence of the original BCC phase with 9R, HCP and FCC closed packed structures. A quantitative ...

476

A multi-marker model for detecting chromosomal segments displaying QTL activity  

Science.gov (United States)

A statistical method is presented for detecting quantitative trait loci (QTLs), based on the linear model. Unlike methods able to detect a few well separated QTLs and to estimate their effects and positions, this method considers the genome as a whole and enables the detection of chromosomal segments involved in the differences between two homozygous lines, and their backcross, doubled haploid, or F[sub 2] progenies, for a quantitative trait. Genetic markers must be codominant, but missing markers are accepted, provided they are missing independently from the experiment. Asymptotic properties, which are of practical use, are developed. This method does not rely on strong genetic hypotheses, and thus does not permit any precise genetic analysis of the trait under study, but it does assess which regions of the genome are involved, whatever the complexity of the genetic determinism (number, effects and interactions among QTLs). Simultaneous use of ...

1993-08-01

477

[Method of determining tissue renin activity using heterologous serum].  

Science.gov (United States)

The authors described a method for determination of tissue renin activity with heterologous substrate. The preparation of the substrate was performed at several stages: salting with amonium sulfate; dialisis of the precipitate till complete separation of amonium sulfate molecules; distruction of angiotensinases by interchangeble souring and alcalization of the medium; lyophylization of the pure substrate. The obtained renin-substrate was preserved in ampules and its usage had a series of advantages--duration, economic, a possibility for standartization of the determination, etc., which were described in details in the article. The described in details also the quantitative determination of the renin activity in the tissues (renal and cerebral) with the help of the obtained substrate as the moments, modiied by the authors, were indicated. PMID:436712

1979-01-01

478

The use of a mesoscale numerical model for evaluations of pollutant transport and diffusion in coastal regions and over irregular terrain  

Energy Technology Data Exchange (ETDEWEB)

A modelling approach is presented that appears to have the potential to provide reliable assessments of pollution concentration in coastal zones and complex terrain, where the assumptions behind current operational air quality models often are inadequate. With the use of a numerical mesoscale model (NMM), physically consistent flow fields can be predicted, thereby providing higher spatial and temporal resolution in the meteorological fields than would be available from a limited number of observation points. These predictions are used to calculate mean trajectories of pollutant parcels, as well as to provide quantitative estimates of pollution concentration using two techniques.

1983-03-01

479

The impacts of climate change on the Finnish economy  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the project was to evaluate the potential influence of global warming on the Finnish economy and well-being during the next 50 to 100 years. In order to achieve this goal a cost-benefit analysis was conducted which produced a quantitative estimate of the economic and partially non-economic effects of the climate change projected to happen in Finland. The analysis utilised the natural scientific evidence produced by other SILMU projects in partial sector models. Also a broader view of the phenomena and the possibilities for restricting greenhouse gas emissions was briefly discussed and surveyed. Two of the more important side-goals were to develop the methodology for country analysis and study the possibilities for adaptation

1996-12-31

480

Tetra Pak : packaging systems and the environment; Tetra Pak : verpakking en milieu  

Energy Technology Data Exchange (ETDEWEB)

First, the problem of food packaging waste is introduced and one of the solutions, the Tetra Pak, is completely described. The article highlights the political sensitivity concerning the landfilling of packaging waste, as is done with the efforts of the Tetra Pak producer concerning the collection of used Tetra Paks and the results of these efforts. The document also informs us about the different recycling options for Tetra Paks, the qualitative prevention (using cleaner packaging), the quantitative prevention (using less packaging) and the sustainable development (using loner lasting packaging). The proposed four-step plan for a communication strategy is company-specific.

1997-05-01

481

Simple method for the high-temperature isolation of /sup 111/In from silver  

Energy Technology Data Exchange (ETDEWEB)

A method is proposed for the quantitative high-temperature isolation of /sup 111/In from silver irradiated by ..cap alpha..-particles into a gas phase containing a mixture of HCl and H/sub 2/O with a total pressure of about 3 Pa for these gases. It is shown that the indium evolved into the gas phase probably occurs in the form of at least three compounds, viz.., the trichloride, monochloride, and oxychloride, which have adsorption temperatures on quartz of around 385, 475, and 655 K, respectively. All these compounds are readily washed from the surface of quartz apparatus by a weak (0.05 M) solution of hydrochloric acid.

1987-07-01

482

Simple method for high-temperature separation of thallium isotopes from a bulk lead target  

Energy Technology Data Exchange (ETDEWEB)

A method is proposed for the quantitative isolation of radiothallium in gas form from proton-bombarded lead of mass up to 20 g. The molten lead is kept at about 800 K in hydrofluoric-acid vapor (HF/H/sub 2/O approx. = 1) at a reduced pressure (less than or equal to4 Pa). We used 99.9% lead with the U-240 cyclotron at the Nuclear Research Institute, Academy of Sciences of the Ukrainian SSR, or the phasotron at the Join Nuclear Research Institute, which gave protons at 65 and 680 MeV correspondingly.

1988-03-01

483

Simple method for high-temperature separation of thallium isotopes from a bulk lead target  

International Nuclear Information System (INIS)

A method is proposed for the quantitative isolation of radiothallium in gas form from proton-bombarded lead of mass up to 20 g. The molten lead is kept at about 800 K in hydrofluoric-acid vapor (HF/H_2O #approx =# 1) at a reduced pressure (#<=#4 Pa). We used 99.9% lead with the U-240 cyclotron at the Nuclear Research Institute, Academy of Sciences of the Ukrainian SSR, or the phasotron at the Join Nuclear Research Institute, which gave protons at 65 and 680 MeV correspondingly.

484

Shell effects in the symmetric-modal fission of pre-actinide nuclei  

International Nuclear Information System (INIS)

Mass distributions of fragments in the low-energy fission of nuclei from "1"8"7Ir to "2"1"3At have been analysed. This analysis has shown that shell effects in symmetric-mode fragment mass yields from the fission of pre-actinide nuclei could be described if one assumes the existence of two strongly deformed neutron shells in the arising fragments with neutron numbers N_1#approx#52 and N_2#approx#68. A new method has been proposed for quantitatively describing the mass distributions of the symmetric fission mode for pre-actinides with A#approx#180-220. (orig.)

1998-09-21

485

Qualitative risk assessment in the ANS LPSD PRA Standard  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a Qualitative/Screening Methodology included in the draft ANS Low Power and Shutdown (LPSD) PRA (Probabilistic Risk Assessment) Standard. The screening methodology can be used to eliminate certain specified shutdown POSs (Plant Operating States) from requiring further quantitative risk assessment in the context of a specified application based on demonstrating that their risk is lower than some predetermined limiting value. The paper also describes a methodology for qualitative risk assessment (QRA) tools that are used to support the screening process. The paper outlines the bases of both methodologies. (authors)

2004-07-01

486

Neutron activation analysis of trace elements in Japanese hormesis cosmetics  

International Nuclear Information System (INIS)

In Japan, cosmetics claiming hormesis effect are available through Internet. Although these cosmetics show the contents, they never mention the minor elements and radioactive sources. The existence of radioisotopes, however, was observed by measurements of the gamma-rays with a HPGe detector. In this study, in order to clarify the contents of trace elements, the hormesis cosmetics including radioactive sources were analyzed using INAA, PGAA and NAA with multiple gamma-ray detection (NAAMG). Nineteen elements were analyzed quantitatively in hormesis cosmetics by INAA, PGAA and NAAMG and 16 elements were detected qualitatively by SEM-EPMA. (author)

2008-12-01

487

Modeling of extended defects in silicon  

Energy Technology Data Exchange (ETDEWEB)

Transient Enhanced Diffusion (TED) is one of the biggest modeling challenges present in predicting scaled technologies. Damage from implantation of dopant ions changes the diffusivities of the dopants and precipitates to form complex extended defects. Developing a quantitative model for the extended defect behavior during short time, low temperature anneals is a key to explaining TED. This paper reviews some of the modeling developments over the last several years, and discusses some of the challenges that remain to be addressed. Two examples of models compared to experimental work are presented and discussed.

1997-11-01

488

Low Power and Shutdown Risk Assessment Benchmarking Study  

Science.gov (United States)

(B204)Probabilistic risk assessment (PRA) insights are now used by the United States Nuclear Regulatory Commission (USNRC) to confirm the level of safety for plant operations and to justify changes in nuclear power plant operating requirements, both on an exception basis and as changeds to a plant's licensing basis. This report examines qualitative and quantitative risk assessments during shutdown plant states, providing feedback to utilities in the use of qualitative models for outage risk management, and also providing input to the development of the American Nuclear Society (ANS) Low Power and Shutdown PRA Standard.

2002-12-15

489

Low Power and Shutdown Risk Assessment Benchmarking Study  

Energy Technology Data Exchange (ETDEWEB)

(B204)Probabilistic risk assessment (PRA) insights are now used by the United States Nuclear Regulatory Commission (USNRC) to confirm the level of safety for plant operations and to justify changes in nuclear power plant operating requirements, both on an exception basis and as changeds to a plant's licensing basis. This report examines qualitative and quantitative risk assessments during shutdown plant states, providing feedback to utilities in the use of qualitative models for outage risk management, and also providing input to the development of the American Nuclear Society (ANS) Low Power and Shutdown PRA Standard.

2002-12-15

490

Josephson effect mm-wave receivers  

International Nuclear Information System (INIS)

Josephson effect heterodyne mixers with external local oscillators are very promising low noise mm-wave receivers for applications such as radio astronomy. Experiments at 36 GHz have shown that both the noise and the conversion efficiency of mixers made using Nb point contacts are in quantitative agreement with values calculated from the resistively shunted junction (RSJ) model. Preliminary measurements at 140 GHz suggest that this agreement extends to higher frequencies. In this paper the theoretical limits to the sensitivity of such receivers are explored as a function of the signal frequency. (Auth.).

491

Interpolation theory and influence of boundary conditions on room air diffusion  

Energy Technology Data Exchange (ETDEWEB)

This paper analyses the errors caused by interpolation from existing cases for assessing indoor air flow, air quality and thermal comfort in an office. A sensitivity study is then provided to determine the influence of several boundary conditions on indoor air diffusion. The research is conducted numerically by using a low-Reynolds-number k-{epsilon} model. It can be concluded that the interpolation errors caused by the variations of solar radiation, window size, heat source location due to lighting, and the surface temperatures of interior walls are small and can be quantitatively determined. But it is difficult to estimate the errors introduced by the variations of furniture location and size. (author).

1991-01-01

492

Impact of different forestry strategies on the function 'carbon wells on the forest planting. Simulation and modelization at the parcel scale; Impact de differentes strategies sylvicoles sur la fonction 'puits de carbone' des peuplements forestiers. Modelisation et simulation a l'echelle de la parcelle  

Energy Technology Data Exchange (ETDEWEB)

In the framework of the carbon storage two forestry methods are analyzed by the author: the standing capitalization (slowing of the crops) and the spices substitution (slow growing species by fast growing species). The construction of a model taking into account the all stage of the carbon implication (biomass, soil, forest products) offers simulation and quantitative results on these methods. (A.L.B.)

2005-10-15

493

Hard X-ray phase imaging and tomography using a grating interferometer  

International Nuclear Information System (INIS)

An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.

2007-07-01

494

Experimental research on X-ray spectrum emitted from hot laser-produced aluminium plasma  

International Nuclear Information System (INIS)

The hot uniform aluminium plasma was produced by irradiating thin aluminium dotted foil smoothly with the 9th 0.53 ?m laser on Shenguang II laser facility. The emitted spectrum was measured from the front and tangential direction of the target with two crystal spectrometers, and the quantitative spectrum from the front of the target was obtained. The state of laser- produced plasma was simulated with the radiation hydrodynamics code MULTI-1D, and the emitted spectrum was calculated with the spectrum code of Collision-Radiation model under the simulated plasma state. The experimental spectrum accords with the simulated one. (authors)

2007-12-01

495

Exact solution to NO/sub 2/ absorption  

Energy Technology Data Exchange (ETDEWEB)

This paper describes an exact solution to the problem of absorbing nitrogen dioxide into aqueous solution, in which case the nitrogen dioxide concentration is allowed to vary over a wide range. The authors have worked on the rate of calcium sulfate dihydrate scale formation on the reverse osmosis membrane and find this phenomena can be treated by the crystallization theory. The authors performed long-term experiments using calcium sulfate dihydrate solution with addition of sodium hexametaphosphate (SHMP) and commercially available organophosphates and investigated the mechanism of the inhibitor's action quantitatively.

1984-04-01

496

Displacement ventilation in industry - a design principle for improved air quality  

Energy Technology Data Exchange (ETDEWEB)

There is very little quantitative documentation of actual improvements resulting from the installation of new general ventilation systems in industrial settings. Therefore the performance of the common mixing design principle was compared to the displacement design principle by means of an intervention study in a workshop (V = 12,000 m[sup 3]), where thermoplastics were moulded. An experimental signal-response tracer gas technique was used. In terms of supplying fresh air to the zone of occupancy the displacement system was better than the mixing system by a factor of 2. In terms of the exposure level to a simulated contaminant (tracer gas) the displacement system was better by a factor 1.5-18. (author)

1992-10-01

497

Conceptual Assessment Framework for Forested Wetland Restoration: The Pen Branch Experience. Restoration of a Severely Impacted Riparian Wetland System - The Pen Branch Project  

Energy Technology Data Exchange (ETDEWEB)

Development of an assessment framework and indicators can be used to evaluate effectiveness of wetland restoration. Example of these include index of biotic integrity and the hydrogeomorphic method. Both approaches provide qualitative ranks. We propose a new method based on the EPA wetland research program. Similar to other methods, indexes are compared to reference communities; however, the comparisons are quantitative. In this paper we discuss the results of our framework using the Pen Branch riparian wetland system as an example.

2000-10-01

498

Comparison of Different Methods for Nonlinear Diffusive Shock Acceleration  

CERN Document Server

We provide a both qualitative and quantitative comparison among different approaches aimed to solve the problem of non-linear diffusive acceleration of particles at shocks. In particular, we show that state-of-the-art models (numerical, Monte Carlo and semi-analytical), even if based on different physical assumptions and implementations, for typical environmental parameters lead to very consistent results in terms of shock hydrodynamics, cosmic ray spectrum and also escaping flux spectrum and anisotropy. Strong points and limits of each approach are also discussed, as a function of the problem one wants to study.

2010-01-01

499

Application of light microscopy to direct coal liquefaction research  

Energy Technology Data Exchange (ETDEWEB)

Light microscopy was used to analyze the effects of added catalyst at different conditions (temperature and reaction times) in liquefaction testing of a low pyritic sulfur bituminous coal. Quantitative changes in vitrinite/vitroplast reflectance of coal and liquefaction residues were shown to be useful markers in analyzing and understanding the role of catalyst during the initial stage of coal particle hydrogenation. Lower reflectance values corresponded to increased conversions up to about the 60 min and 375{degrees}C experimental conditions. Microscopical observation of liquefaction residues also revealed the presence of `wall scales` of varying width.

1998-01-01

500

Analysis of the chemical transformations induced at the surface of polyacrylonitrile and polymethacrylonitrile films by 5 keV proton beams  

Energy Technology Data Exchange (ETDEWEB)

In this work, the chemical transformations induced by 5 keV protons (10{sup 6} ion cm{sup -2}) at the surface of 0.4 {mu}m polyacrylonitrile and polymethacrylonitrile films are analysed by XPS and IRRAS. Spectroscopic changes in both the polymers are globally similar, the most significant feature being a lower relative concentration of nitrogen with respect to carbon closer to the surface. Quantitatively, this change is more marked in the case of polyacrylonitrile which suggests a direct relation with the hydrogen in {alpha} to the nitrile function.

1999-05-02