The ultimate compressive strength of 36 thoracolumbar vertebrae was determined experimentally. In addition, the trabecular bone mineral content was measured by single energy quantitativecomputedtomography. The areas of fractured endplates were also determined by computedtomography. The results show that a linear relationship exists between the compressive strength and the product of bone density and endplate area. These data allow an in vivo prediction of vertebral body strength using a noninvasive method with a standard error of estimate amounting to less than 0.95 kN. PMID:3212488
The authors have evaluated bone mineral content in the vertebral spongiosa by means of ComputedTomography. The method proposed by Genant and Cann [17, 18] has been applied to examine 164 healthy volunteers and 108 patients. Both healthy males and females showed a progressive bone mineral loss increasing with age; the bone mineral loss was most severe in females during the 4th and 5th decade of life. Pathology included patients with osteoporotic fractures (vertebral and femural neck), patients with partial gastrectomy, renal failure, primary hyperparathyroidism, Cushing syndrome, corticosteroid therapy. Bone mineral values were significantly lower in most pathologic groups. ComputedTomography proves thus to be a valuable method to assess bone mineral content and to identify patients at risk for fractures.
A QuantitativeComputedTomography (QCT) method, simplifying the well-known technique proposed by Genant (1982) and applied to a standard third generation whole body CT scanner is described. This technique was applied in the measurement of the trabecular bone which has high sensitivity for metabolic changes. The BMC (Bone Mineral Content) measured in different groups of subjects (healthy postmenopausal patients versus women with postmenopausal osteoporosis) showed a highly significant difference (p<0.001). The precision of repositioning (coefficient of variation 1.8% to 2.3%, obtained in healty male patients) and the good, linear relationship computed from the phantom values, minimize measurement errors. Since this method is quickly applied and involves low-dose radiation-exposure, it could be introduced in the clinical study of metabolic bone diseases.
A specific application of single photon emission tomography to the relative quantitation of the pituitary region is described together with the results obtained in 19 patients with pituitary adenoma...Full Text Available
138 unselected head tomographies of children by computer are reported and analysed. The major aspect stressed by the authors is the excellent precision of this radiological technique.
In 15 children (in age 2 weeks - 15 years) the computertomography beside radiological examination was done because of mediastinal diseases. In all cases the computertomography was valuable. In 4 cases obtained results have changed diagnostic conclusions. The examples are described showing the usefulness of the computertomography as supplementary diagnostic method in mediastinal diseases in children.
In a joint study conducted by the University Clinic of Radiology, Graz, and the Medical University Clinic, Innsbruck, the results of computertomography examinations of the abdomen and pelvis in 23 cases of tumours in children are discussed. In children computertomography resents special difficulties on account of the very poorly developed fatty layers between the organs and the increased incidence of movement artifacts. The importance of computertomography for the diagnosis of abdominal and pelvic tumours is discussed.
A new microdensitometry method for quantitative assessment of bone mineral content using Fuji computed radiography (FCR) was developed and the results were compared with those obtained by the conventional film-screen method. Using both methods, X-ray pictures of the 2nd metacarpal bone were taken with a reference aluminum step wedge in nine normal subjects and nine parameters representing the width and density of bone marrow and cortex were calculated in middle of the bone shaft. Interobserver reproducibility assessed for three parameters was significantly higher in the FCR method than the conventional one. The value of {Sigma}GS computed by the FCR method, that is equivalent to the net bone density of the transverse section of the shaft, showed higher correlation with the one obtained by computedtomography in comparison with the conventional method. In our FCR method, moreover, ...
A new microdensitometry method for quantitative assessment of bone mineral content using Fuji computed radiography (FCR) was developed and the results were compared with those obtained by the conventional film-screen method. Using both methods, X-ray pictures of the 2nd metacarpal bone were taken with a reference aluminum step wedge in nine normal subjects and nine parameters representing the width and density of bone marrow and cortex were calculated in middle of the bone shaft. Interobserver reproducibility assessed for three parameters was significantly higher in the FCR method than the conventional one. The value of #SIGMA#GS computed by the FCR method, that is equivalent to the net bone density of the transverse section of the shaft, showed higher correlation with the one obtained by computedtomography in comparison with the conventional method. In our FCR method, moreover, ...
A method for elucidating complex abnormalities of CSF circulation by using a positive contrast medium (metrizamide) and computertomography is described. The technique for the method, the results and their clinical significance is demonstrated. The value of this method is compared with traditional ventriculography and with computertomography without the use of contrast medium. It is shown that the technique represents an important extension of the scope of computertomography.
A thermal neutron imaging facility for real-time neutron radiography and computedtomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere.
A thermal neutron imaging facility for real-time neutron radiography and computedtomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere
Absolute measurements of cerebral blood flow (CBF) are an important endpoint in studies of cerebral pathophysiology. Currently no accepted method exists for in vivo longitudinal...Full Text Available
This study examines the effects of intravenous infusion of adenosine and sublingual nitroglycerin on coronary angiograms obtained by current-generation multidetector computedtomography. We assessed...Full Text Available
Background and objectives: Management of incidental renal artery and kidney abnormalities in patients undergoing computedtomography scans is a clinical challenge because their frequency in healthy...Full Text Available
Computertomography used in the diagnosis of tumours is described in the light of particularly great diagnostic difficulties in children. Computertomography was applied in 12 cases. A high diagnostic value of this method was demonstrated, which makes possible a more accurate diagnosis of the position of the tumour, its size, and expanding tendency. The possibility of estimating healthy tissues and organs, and those with pathological changes on the basis of differences in their density with a detection threshold at 0.5% density difference facilitates not infrequently preoperative diagnosis raising the value of the method.
Noninvasive prediction of vertebral body strength under compressive loading condition is a valuable tool for the assessment of clinical fractures. This paper presents an effective specimen-specific approach for noninvasive prediction of human vertebral strength using a nonlinear finite element (FE) model and an image based parameter based on the quantitativecomputedtomography (QCT). Nine thoracolumbar vertebrae excised from three cadavers with an average age of 42 years old were used as the samples. The samples were scanned using the QCT. Then, a segmentation technique was performed on each QCT sectional image. The segmented images were then converted into three-dimensional FE models for linear and nonlinear analyses. A new material model was implemented in our nonlinear model being more...
A case of intrathoracic lipoma in a child is presented. The diagnosis was made before operation by means of computer-assisted tomography, a non-interventional procedure.
In the search for new brain imaging agents for use with single photon emission computedtomography (SPECT), quantitative structure activity relationship (QSAR) analysis of the correlations between initial brain uptake and physicochemical parameters like lipophilicity, log P, molecular weight, log MW and log U/D (undissociated/dissociated), of the {sup 99m}Tc-DADT (diaminedithiol) complexes and {sup 99m}Tc-PAO (propyleneaminoxime) complexes have been analyzed. High correlations are found for both the {sup 99m}Tc-DADT complexes (r = 0.94) and for the {sup 99m}Tc-PAO complexes (r = 0.83) which are significant at 99.9 and 99.5 percentile level, respectively. These results will help the further design of better ligands for {sup 99m}Tc in brain imaging. (author).
Computed tomographic findings in developmental brain anomalies are more easily classified when the system used is based on embryogenesis related to morphology. Analysis of computed tomographic findings in a series of 154 patients with brain anomalies (Chiari malformation not included) revealed that specific examples of abnormalities occurring in major stages of brain development may be recognized by computedtomography. This paper deals with a group of patients with abnormalities that reflect a disturbance in neuronal migration. (orig.).
The authors assess the role of Computed Topography in the diagnosis and management of multiple myeloma (MM) and investigate if ComputedTomography findings can influence the clinical approach, prognosis and treatment. 273 multiple myeloma patients submitted to ComputedTomography June 1994, to December, 1996. The patients were 143 men and 130 women (mean age: 65 years): 143 were stage I, 38 stage II and 92 stage III according to Durie and Salomon's clinical classification. All patients were submitted to blood tests, spinal radiography and ComputedTomography, the latter with serial 5-mm scans on several vertebral bodies. ComputedTomography despicted vertebral arch and process involvement in 3 cases with the vertebral pedicle sign. Moreover, Computed ...
PurposeEarly detection of appendicitis has increased due to development of computedtomography and ultrasonography, yet we are frequently meeting complicated appendicitis, including...Full Text Available
It is reported on examination-technical possibilities with craniocerebral ComputerTomography in the peri- and postnatal period. Some typical tomographic images from a 17 1/2 months period in our own patient material of 327 children are demonstrated. The special advantages of this new technical-extensive method are: exact diagnoses, observation possibility of the longitudinal section, and the absolute harmlessness to the child.
We retrospectively studied the computedtomography scans of the orbit in 75 patients in order to identify the presence of incidental calcifications (scleral and trochlear apparatus calcifications.). These imaging findings should integrate the vast list of differential diagnosis of orbital calcifications, as they may help radiologists to distinguish these calcifications from orbital foreign bodies. (author)
The experiences are described of the examination of orbita in children using computertomography (CT). Over a period of four years 42 examinations were performed of children in the age ranging between 7 months and 15 years, i.e., 2.7 percent of all CT examinations performed. The highest diagnostic yield was in orbita tumours. The possibilities of CT are demonstrated on examples.
Several recently introduced 'new' techniques in computedtomography - iterative reconstruction, gated cardiac CT, multiple-source, and dual-energy CT - actually date back to the early days of CT. We review the historic origins and evolution of these techniques, which may provide some insight into the latest innovations in commercial CT systems. (orig.)
Aim of the work was to describe the noninvasive assessment of bone mineral density, geometrical and biochemical properties in premenopausal women with dietary intake of phytoestrogens and comparison of these parameters with those of age-matched female subjects with Mediterranean dietary intake lacking in these substances. Volumetric cortical, trabecular and total mineral density and bone geometrical properties were evaluated with peripheral quantitativecomputedtomography (pQCT) at the distal radius of the non dominant forearm. pQCT showed higher bone mineral density (total and trabecular) and SSI values in premenopausal with dietary intake of phytoestrogens. Despite the lack of statistical significance, these preliminary results, should further support the few literature findings about the potential role of phytoestrogens consumption in preventing trabecular bone loss. However, further studies are warranted to evaluate ...
Surgical resection is the only curative treatment strategy for intrahepatic cholangiocarcinoma (CC). Therefore, accurate staging is essential for appropriate management of patients with CC. We assessed the usefulness of 2-["1"8F]fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) in the staging of CC. We undertook a retrospective review of FDG PET images in 21 patients (10 female, 11 male; mean age 57 years) diagnosed with CC. Ten patients had hilar CC and 11, peripheral CC. Patients underwent abdominal magnetic resonance imaging (MRI) (n=20) and computedtomography (CT) (n=12) for the evaluation of primary tumours, and chest radiography and whole-body bone scintigraphy for work-up of distant metastases. For semi-quantitative analysis, the maximum voxel standardised uptake value (SUV_m_a_x) was obtained from the primary tumour. All peripheral CCs showed intensely increased FDG uptake, and ...
A cross sectional study on the mineral density of the 3rd lumbar vertebral trabecular bone was carried out in 123 children less than 15 years old, comprising 44 controls, and 79 patients affected with conditions which are at risk for developing metabolic derangement of skeletal bone (34 patients taking antiepileptic drugs (AED), 29 undergoing glucocorticoid (GC) therapy and 16 bedridden patients), by using quantitativecomputedtomography (QCT) with a CaCO{sub 3} phantom. Serum Ca and alkaline-phosphatase (Alp) levels were measured at the time of QCT examinations in all. The results obtained were as follows: The QCT values in the control children showed neither age dependency nor a sexual difference before puberty. The QCT values in each group showed significant difference with one another; the control group>the AED group>the GC group>the bedridden group (p<0.05{approx}0.005). The serum Ca levels in each ...
Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computertomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained
The radiologic appearance of inflammatory and tumorous lesions in the iliac bone is characterized by destructive alterations and consolidations simultaneously. This pattern is nonspecific. The value of plain films of this area is compromised by the anatomy of the iliac bone and by overlying structures. Therefore tomography, computertomography and bone scans are necessary. Difficulties in differentiation between benign and malignant lesions are discussed and case reports are given. The importance of histologic examination is stressed.
Computer-Aided Prediction of Chemical Ecotoxicity on the basis of Quantitative Structure-Activity Relationships with the Use of Physico-Chemical Descriptors, Including H-bond Parameters
BackgroundSeveral fractal and non-fractal parameters have been considered for the quantitative assessment of the vascular architecture, using a variety of test specimens and of computational...Full Text Available
The authors compared unenhanced and contrast-enhanced fast MRI and Computerized Tomography in the detection of liver metastases. Eleven patients with single or multiple hepatic lesions (42 in all) were submitted to V and magnetic resonance studies; T1- and T2- weighted TSE, T2-weighted TSE with fat suppression, unenhanced breath-hold TFE and early or delayed enhanced breath-hold TFE images were acquired with a 1.5 T superconductive magnet (Philips NT). The quantitative analysis of all magnetic resonance images was performed for contrast/noise ratio (CNR) and number of detected lesions; magnetic resonance and Computerized Tomography images were also compared qualitatively for lesion conspicuity, anatomical structure identification and artifacts. The results were compared with Student's test. Early enhanced breath-hold TFE was statistically superior to T1-weighted TSE (p = .0009), T2-weighted TSE (p = .01) and Computerized ...
BackgroundThe precision in carbon ion radiotherapy depends on the calibration of Hounsfield units (HU) as measured with computedtomography (CT) to water equivalence. This calibration...Full Text Available
ObjectiveTo refine the CT prediction of emphysema by comparing histology and CT for specific regions of lung. To incorporate both regional lung density measured by CT and cluster...Full Text Available
Scatter correction is crucial to the quality of reconstructed images in x-ray cone-beam computedtomography (CBCT). Most of existing scatter correction methods assume smooth scatter distributions. The...Full Text Available
BackgroundIn primary hyperparathyroidism (PHPT) the predictive value of technetium 99m sestamibi single emission computedtomography (Tc99m-MIBI-SPECT) for localizing pathological...Full Text Available
To determine the diagnostic accuracy of iofetamine hydrochloride I 123 (IMP) with single photon emission computedtomography in Alzheimer's disease, we studied 58 patients with AD and 15 age-matched healthy control subjects. We used a qualitative method to assess regional IMP uptake in the entire brain and to rate image data sets as normal or abnormal without knowledge of subjects'clinical classification. The sensitivity and specificity of IMP with single photon emission computedtomography in AD were 88% and 87%, respectively. In 15 patients with mild cognitive deficits (Blessed Dementia Scale score, less than or equal to 10), sensitivity was 80%. With the use of a semiquantitative measure of regional cortical IMP uptake, the parietal lobes were the most functionally impaired in AD and the most strongly associated with the patients' Blessed Dementia Scale scores. These ...
The purpose of this work is to develop a novel feature-based registration strategy to automatically map the rectal contours from planning computedtomography (CT) (pCT) to cone beam CT (CBCT). The rectal...Full Text Available
RATIONALE AND OBJECTIVESNon-invasive longitudinal imaging of tumor vasculature could provide new insights into the development of solid tumors, facilitating efficient...Full Text Available
AIM: To improve the diagnosis of heterotopic pancreas by the use of contrast-enhanced computedtomography (CT) imaging and CT virtual endoscopy (CTVE).METHODS: A total of six patients with heterotopic...Full Text Available
Due to the widespread clinical use of imaging modalities such as ultrasonography, computedtomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available
The diagnostic accuracy of computedtomography (CT) in several patterns of thoracic and abdominal fatty masses, has been examined. In selected cases our findings overlap the features of the recent literature. The possibility of surgical therapy in peculiar cases of adipose deposits, commonly esteemed benign, is considered.
We report an unusual patient with primary adenocarcinoma of lung causing malignant pleural and pericardial effusions. The diagnosis was made only at autopsy as his staging computedtomography scan of...Full Text Available
Purpose: Reverse helical cone-beam computedtomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available
Computedtomography allows today to reconstruct three-dimensional (eD) images fram axial scans. The authors report their experience in cranio-facial pathology achived in two Departments of Radiology (University of Trieste, Italy and University of Standford, California). 3D images have been realized using two different softwares, one of which allows to reconstruct both soft tissue and bone structures. The application in maxillo-facial traumas, cranio-facial malformations and head tumours are disscussed. 3D images turned out to be very useful for the optimal visualization and for the spatial demostration of the lesion and have potential applications in cranio-facial surgery and radiotherapy.
Snapping or grating scapula is a condition of the shoulder girdle in which the patient complains of pain and an audible snapping sound which may be associated with pain. We evaluated the diagnostic value of the computedtomography (CT) scans using the clinical diagnosis of a grating scapula as the gold standard. This retrospective study reports the sensitivity, specificity, likelihood ratio and receiver operator characteristic curve for the CT scans and the k value as a measure of the interobserver agreement. None of the parameters validated the examination. We therefore concluded that CT scans are inappropriate for differentiation between a grating scapula and a normally functioning shoulder except in cases where bony abnormalities are present. (orig.)
Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computedtomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).
Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computedtomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).
A thermal neutron imaging facility for real-time neutron radiography and computedtomography has been developed at the University of Texas reactor. The facility produced good-quality radiographs and two-dimensional tomograms. Further developments have been recently accomplished. A computer software has been developed to automate and expedite the data acquisition and reconstruction processes. Volume tomographic visualization using Interactive Data Language (IDL) software has been demonstrated and will be further developed. Volume tomography provides the additional flexibility of producing slices of the object using software and thus avoids redoing the measurements.
Thirty-seven patients with histologic proof of cholangiocarcinoma at the confluence were examined by computedtomography (CT) to determine whether this examination is of value in the assessment of these patients for surgery and whether there are any features specific to this type of tumor. Thirty-two patients showed intrahepatic duct dilatation; six of these showed dilatation of ducts in one lobe only. Eighteen patients had intrahepatic low-attenuation areas, while eight had a mass lesion in the porta hepatis. The results of this study show that CT provides useful anatomic information preoperatively but that the appearances are nonspecific. Lobar atrophy is highly suggestive of hilar cholangiocarcinoma, either of long-standing or with unilateral portal venous involvement.
In order to evaluate the role of ComputedTomography (CT) in prediction of nature, staging and follow-up of soft-tessue tumors, the authors examined by CT 124 patients with soft tissue neoplasms who later underwent surgery (116 cases) or fine needle biopsy (8 cases). Comparison between CT and surgical or anatomical results showed that CT was able to correctly predict the benignancy or malignancy of the masses in 76% of cases but it was very seldom able to allow an hystological prediction. On the contrary CT was found to be a very useful tool for pre-therapeutic staging and follow-up of the tumors, because it gave many diagnostic information which influenced therapeutic choiches and strategies.
Computedtomography (CT) has already proved extremely effective both in cerebral and abdominal pathology. Several recent publications describing first heterogeneous series [1, 2, 7, 11-17], then studies of a single type of lesion [3-6, 8] have illustrated its usefulness in the study of bone lesions. This report deals with 41 cases of Ewing's sarcoma studied by CT at the Institut Gustave Roussy from October 1977 to July 1981, and tries to show both the limitations and indications of this technique for the diagnosis, treatment, and follow-up of Ewing's sarcoma as well as in the diagnosis of any eventual recurrence. (orig.).
In order to stress the role of computedtomography (CT) in the evaluation of benign spinal osteoblastoma, the authors examined by CT 10 patients with surgically and histologically proved osteoblastomas of the spine. Basing on surgical and histopathological findings CT proved to be a very important method for attesting the presence of the tumors (usually showed by radiographic examination), and specially for their staging and follow-up. CT in fact showed the real extent of the tumor into the spinal canal and towards the paraspinal soft tissues, and allowed the aerly detection of post surgical relapses. The authors conclude that CT is a primary diagnostic modality for preoperative planning and follow-up of benign osteoblastoma.
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computedtomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computedtomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter.
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computedtomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).
Background: High-resolution computedtomography is the image procedure of choice in the evaluation of interstitial lung disease. Multidetector-row computedtomography provides the possibility of simultaneous reconstruction of thin and thick slices from the same raw data, acquired from one single series. Thus, it may be tempting to exclude the step-and-shoot series. Purpose: To compare high-resolution computedtomography (HRCT step-and-shoot) from single-slice CT (SSCT) and 16-channel multidetector CT (MDCT) in terms of visibility and motion artifacts, and to investigate whether thin images reconstructed from helical MDCT are equal to or better than conventional HRCT by SSCT in terms of visibility and motion artifacts. Material and Methods: 20 patients underwent HRCT step-and-shoot by SSCT (SSCT step-and-shoot) and MDCT (MDCT step-and-shoot), and a helical MDCT ...
Forty-four patients with small cell carcinoma of the bronchus underwent CT and MR studies of the brain to detect cerebral metastases. All patients were studied with contrast-enhanced CT scans, short (T1-weighted) and long (T2-weighted), spin-echo (SE) and FLASH 90 grades sequences were also obtained. A quantitative comparison of the results was carried out to assess the sensitivity of the different techniques in the detection of brain metastases according to lesion diameter. Metastases were identified in 19/44 patients (43%). All techniques detected the lesions >2 cm; of the metastases <2 cm, 63/124 (51%) were detected only by GdDTPA SE-T1 and FLASH sequences and 11 more (9%) only by Gd-DTPA SE-T1 scans. All the lesions identified oh enhanced CT scans or on T2-weighted images were easily detected by Gd-DTPA scans. CT sensitivity was higher than that of pre-contrast SE-T1 and FLASH studies and only slightly lower than that of T2-weighted images. As for lesions ...
Initial major applications of neutron radiography (NR) to nuclear engineering were nondestructive inspections of nuclear fuel, control rods, reactor materials and some other components. Increase in the available neutron flux over 10{sup 8} n/cm{sup 2}s at the JRR-3M thermal neutron radiography facility (TNRF) in 1991 has expanded the application field to the dynamic but clear imaging of moving objects and fluid phenomena. The JRR-3M TNRF is facilitated with three major imaging systems, being characterized by spatial and/or temporal resolutions: 1. Static neutron radiography (SNR), 2. real-time neutron radiography (RNR) with an imaging rate of 30 frames/s and 3. High-frame-rate neutron radiography (HFRNR). SNR has been used for three-dimensional visualization of air-water two-phase flows in a simulated rod bundle. Three-dimensional computedtomography clearly illustrated average void fraction distributions around tie spacers. RNR has been used ...
CT is the most accurate method to detect pulmonary emphysema in vivo. They compared prospectively two different methods for emphysema quantitation in 5 normal volunteers and 20 consecutive patients with chronic obstructive pulmonary disease (COPD). All subjects were submitted to function tests and HRCT; three scans were acquired at preselected levels during inspiration. The type and extent of pulmonary emphysema were defined by two independent observers under blind conditions. Disagreements were subsequently settled by consent. All subjects were also examined with expiratory spiral CT using a density mask program, at two different cut-off levels (-850,-900 HU). Visual score and expiratory spiral density mask values (-850 HU) were significantly correlated (r = 0.86), but the visual extent of emphysema was always higher than shown by expiratory spiral CT. The emphysema extent assessed with both CT methods correlated with the function result of expiratory airflow ...
CT is the most accurate method to detect pulmonary emphysema in vivo. They compared prospectively two different methods for emphysema quantitation in 5 normal volunteers and 20 consecutive patients with chronic obstructive pulmonary disease (COPD). All subjects were submitted to function tests and HRCT; three scans were acquired at preselected levels during inspiration. The type and extent of pulmonary emphysema were defined by two independent observers under blind conditions. Disagreements were subsequently settled by consent. All subjects were also examined with expiratory spiral CT using a density mask program, at two different cut-off levels (-850,-900 HU). Visual score and expiratory spiral density mask values (-850 HU) were significantly correlated (r = 0.86), but the visual extent of emphysema was always higher than shown by expiratory spiral CT. The emphysema extent assessed with both CT methods correlated with the function result of expiratory airflow ...
The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computedtomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...
The paper investigates computerized tomography capabilities in showing vascular complications secondary to intestinal obstruction and for assessing the site and cause of obstruction. [Italian] Scopo del lavoro e' lo studio dell'uso della tomografia computerizzata nel riconoscimento di complicanze vascolari secondarie ad occlusione intestinale e della presenza, della natura e della sede dell'ostacolo alla canalizzazione intestinale.
Positron-emission tomography (PET) and PET/CT (computedtomography) are becoming increasingly important for diagnosis and treatment of cancer. Clinically relevant changes can sometimes be seen on PET that are not seen on other imaging modalities. However, PET is not suitable for guiding biopsy as the images are not obtained in real-time. Therefore, our research group has begun developing a concept for PET/CT-guided interventional procedures. This paper presents the rationale for this concept, outlines our research plan, and includes an initial study to evaluate the relative sensitivity of CT and PET/CT in detecting suspicious lesions. (orig.)
Positron emission tomography (PET) and X-ray computedtomography (CT) performed with PET/CT cameras allow us to obtain concurrently information on the presence and degree of alterations of myocardial perfusion and metabolism and on coronary arteries calcification. Furthermore, by gated myocardial perfusion studies, PET may provide crucial information on regional coronary blood flow reserve and endothelial dysfunction. A number of recent papers provide some insight on the potential of PET/CT in cardiology and in the assessment of various cardiovascular diseases including various types of vasculitis and metabolic diseases.
Computedtomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computedtomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. Future applications ...
Computedtomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computedtomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. Future applications ...
In less than a decade computedtomography (CT scanning) had a profound impact on diagnostic radiology. Radiology of the orbit is no exception. As early as 1973, reports published in the radiological literature indicated that this new noninvasive imaging method was a highly effective way of demonstrating intraorbital mass lesions. As CT scanners became widely available, computedtomography became a significant adjunct to ophthalmological diagnosis. Today the main indications for CT scanning of the orbit are: (1) suspected mass lesions, most frequently presenting as exophthalmos, (2) orbital trauma, including foreign bodies, (3) some congenital anomalies, and (4) suspicion of extension into the orbit of extraorbital disease processes. Along with ultrasonography, another new noninvasive imaging technique, CT has replaced a number of more invasive and often less effective diagnostic methods, such as orbital ...
Dilatation of the azygos vein is usually due to increased pressure or flow, rarely is it diopathic. Another cause is so-called continuation of the azygos in cases of absence of the hepatic segment of the inferior vena cava. The method of choice for the investigation of azygos dilatation nowadays is computer tomotgraphy. Anomalies of the inferior vena cava can be recognised in this way unequivocally by a non-invasive method. Computertomography frequently shows important additional abnormalities (e.g. situs inversus, polysplenia), since it demonstrates all organs situated in the plane of section. (orig.).
The diagnostic accuracy of sialography and ultrasonography (US) in the evaluation of parotid masses is evaluated. Furthermore the role of computedtomography (CT) in this pathology is discussed. In the personal experience US proved to be the best method in the recognition of a parotid tumor while sialography was superior in defining the intra or extraparotid site. The two investigations showed the same accuracy in the definition of benign or malignant nature of the mass. Therefore we consider US the only investigation in most istances; sialography could be performed when the site of the lesion is uncertain or an inflammatory lesion is suspected. CT is never the first investigation; its use is limited to a low number of cases, mainly for the evaluation of large masses and when the association US-sialography does not allow a sure diagnosis.
Six patients with diskitis following lumbar disk surgery were investigated by ComputedTomography (CT). Four patients underwent CT in a rather early phase of the disease (5-37 days after the onset of the symptoms): a posterior paravertebral fluid collection was always recognized, while the plain film was normal. Later on (2-4 months), the classical signs of diskitis were evident, with both CT and the plain film. The collection was always present at CT. A reintervention, performed on 3 patients, revealed the purulent content of the collections. It seems reasonable to suggest a relationship between the collection and the subsequent diskitis; the collection is probably an early sign of the disease. Its detection is of grat value, because it could allow an immediate and adequate therapy. The authors stress the usefulness of performing CT in an early phase on this kind of symptomatic patients.
Hilar cholangiocarcinoma is associated with a dismal prognosis; however, curative resection may offer a chance of cure. Various factors should be considered in the surgical planning for curative resection. These factors include extent of bile duct involvement, relationship between portal vein and tumor involvement, diffuse hepato duodenal ligament infiltration, vascular invasion, lymph node metastasis, peritoneal seeding, and hepatic volume. Using high-quality volume data from multidetector-row computedtomography (MDCT) and adequate postprocessing images, radiologists can provide various types of information, imperative for curative resection of a hilar cholangiocarcinoma. This review illustrates the role of MDCT in the preoperative workup of hilar cholangiocarcinoma.
Purpose We evaluated low-contrast injection protocols for coronary computedtomography angiography (CTA) using a 64-detector scanner and the test bolus technique. Materials and methods We randomly assigned 60 patients undergoing coronary CTA to one of two contrast material (CM) injection protocols. For the lowcontrast dose protocol (Plow), the patients received injections of iohexol-350 [0.7 ml/kg body weight (BW)] during 9 s, and the test-bolus technique was used. Under the conventional protocol (Pconv), they received iohexol-350 (1.0 ml/kg BW) during 15 s, and bolus tracking was used. We compared the protocols for attenuation values in the ascending aorta and coronary arteries and for the amount of CM required. Results There was no significant difference in the mean CT attenuation of the...
Purpose Video-assisted thoracic surgery (VATS) has recently been adopted for complicated anatomical lung resections. During these thoracoscopic procedures, surgeons view the operative field on a two-dimensional (2-D) video monitor and cannot palpate the organ directly, thus frequently encountering anatomical difficulties. This study aimed to estimate the usefulness of preoperative three-dimensional (3-D) imaging of thoracic organs. Methods We compared the preoperative 64-row three-dimensional multidetector computedtomography (3DMDCT) findings of lung cancer-affected thoracic organs to the operative findings. Results In comparison to the operative findings, the branches of pulmonary arteries, veins, and bronchi were well defined in the 3D-MDCT images of 27 patients. Conclusion 3D-MDCT imag...
Herein we present an impact of diagnosis by enhanced multidetector-row computedtomography and magnetic resonance imaging for extrahepatic cholangiocarcinoma (ECC). Although the diagnosis against the longitudinal stromal extension and surrounding tissue invasion of ECC by multi detector row CT (MDCT) and MRI was very strict, we could not detect any superficial mucosal spread (SMS). Furthermore, the diagnosis of lymphnode metastasis by MDCT/MRI was miserable. We believe that misdiagnosis of SMS is permissible since positive mucosal but not stromal surgical margin was not a significant factor influencing the postoperative prognosis. However, further advances in imaging diagnosis for ECC is needed. (author)
A thermal neutron imaging facility for real-time neutron radiography and computedtomography has been developed at the University of Texas reactor. The facility produced a good-quality radiographs and two-dimensional tomograms. Further developments have been recently accomplished. Further developments have been recently accomplished. A computer software has been developed to automate and expedite the data acquisition and reconstruction processes. Volume tomographic visualization using Interactive Data Language (IDL) software has been demonstrated and will be further developed. Volume tomography provides the additional flexibility of producing slices of the object using software and thus avoids redoing the measurements.
Colorectal cancer (CRC) is the most common cause of cancer death among Canadian non-smokers. Each year about 21,500 Canadians are diagnosed with CRC. Ninety percent of cases occur in people aged 50 years or older. An estimated 4,800 Canadian men and 4,100 Canadian women die each year from the disease. About 75% of all new CRC cases arise in people with no known risk factors. Computedtomography colonography (CTC), a cross-sectional imaging examination that permits complete structural examination of the colon, shows promise as a tool for CRC screening. This article reviews the rationale for CRC screening, currently recommended Canadian and American screening guidelines and screening tools, and current evidence supporting CTC as a CRC screening tool and its advantages over conventional screening methods. (author)
Colorectal cancer (CRC) is the most common cause of cancer death among Canadian non-smokers. Each year about 21,500 Canadians are diagnosed with CRC. Ninety percent of cases occur in people aged 50 years or older. An estimated 4,800 Canadian men and 4,100 Canadian women die each year from the disease. About 75% of all new CRC cases arise in people with no known risk factors. Computedtomography colonography (CTC), a cross-sectional imaging examination that permits complete structural examination of the colon, shows promise as a tool for CRC screening. This article reviews the rationale for CRC screening, currently recommended Canadian and American screening guidelines and screening tools, and current evidence supporting CTC as a CRC screening tool and its advantages over conventional screening methods. (author)
ComputedTomography (CT) of the spine was performed on 17 patients with myeloma in order to assess the role of the technique in recognizing and evaluating the extent of the lesions. Myelomatous lesions followed two patterns at CT: first of all, multiple focal lesions, whose density is either solid, liquid, or fatty; second, an extensive pattern involving the spongiosa of the vertebra, including the posterior arch. CT detected more lesions than conventional radiology; furthermore, the extent of the lesions was much better demonstrated by CT. CT should thus be performed: a) in case of pain and/or neurological findings in negative radiological examinations; b) to evaluate the extent of myelomatous lesions (mainly in the spine); c) in solitary myeloma CT may be performed on different bone segments with clinical symptomatology but normal X-ray findings.
In 9 over 12 patients who underwent cardiac transplantation computedtomography was performed. In 5 of them CT was obtained also before the surgical treatment. In all patients angio-CT technique was performed, while the ECG-gated technique was employed only before surgery. CT shows changes in morphology of both atria but over all of the right one, and rotation of the heart on the longitudinal axis. The conditions of the pericardium are particulary well demonstrated: in 5 cases pericardial effusion was observed, 3 times localized and 2 times diffuse. Only in 1 patient a small thrombus in the right atrium was demonstrated. CT allows the possibility to obtain simultaneously information on mediastinum, lung and pleura. Pleural effusion, pulmonary infections and mediastinal complications are easily demonstrated.
Fuji Computed Radiography (FCR) is a new system of digital radiography that is based on the latest computer technologies. We applied this FCR system to the X-ray diagnosis of the laryngeal disease. Twenty patients with various laryngeal diseases were evaluated by both FCR frontal tomography and conventional screen-film frontal tomography under the same exposure condition. Both tomograms were then compared on the subject of the clarity of delineation of laryngeal structures. As the result, FCR tomograms revealed the feature of the laryngeal lumen and cartilages more clearly than conventional tomograms. In addition, energy subtraction method, which is one of FCR image processing systems, was presented as a new technical procedure to extinguish cervical spine shadows in plain anteroposterior laryngeal X-photograph. We stress that FCR system is the suitable procedure for X-ray analysis of laryngeal ...
A prospective comparative study with pathology was performed to assess the clinical value of ComputedTomography (CT) and endoscopic ultrasound (EUS) for nodal staging in lung cancer. A total of 329 nodal stations were dissected or sampled and 755 lymph nodes were examined at histology. On a pre-station basis, CT had greater sensitivity (74%) than EUS (56%), but EUS was more specific (83% versus 93%). The accuracy rates of the two techniques were similar. In conclusion, endoscopic ultrasound should be part of a routine preoperative diagnostic approach to non-small-cell lung cancer., because of its high specificity. Results can be improved when EUS and CT are combined., which suggests that these imaging modalities should be used together in selected patients for the noninvasive staging of non-small-cell lung cancer to identify local lymphatic spread.
An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.
Thirty-five patients with temporal bone fractures were examined; the fractures were sometimes associated with dislocation of the assicular chain caused by road fatalities. ComputedTomography (CT) was performed either because of the presence of clinical symptoms associated with trauma of the temporal bone, because of a hemotympanum discovered during a CT scan of the brain. Thirty-three fractures were detected: 19 longitudinal, 6 transverse, and 8 complex. An incudostapedial dislocation was also detected, together with a displacement of a stapedial prosthesis from the lenticular process of incus, and 3 incus-malleus dislocation associated with fractures. High resolution CT allows the precise definition of the course of the fractures, of the associated dislocation of the ossicular chain, and of facial nerve lesion, thus allowing a more accurate surgical intervention. In the examination of the temporal bone, high resolution CT is preferible to ...
In earliest works devoted to proton computedtomography it was shown that the advantage of pCT image reconstruction appears when the energy is close to the Bragg peak region, since the proton passes the object. This effect provided by the Bragg peak makes the computerized tomography with protons possible. However, when decreasing the initial proton energy, with the increase of the irradiation dose, there are two effects that work simultaneously in opposite ways. First, the energy loss of a proton in an object becomes bigger at small initial energy. At the same time decreasing of the proton energy results in the increase of the energy straggling, requiring a larger number of protons. In this work the radiation dose dependence on the proton initial energy was studied using analytical formulas and computer simulations. The investigation determined that the radiation dose practically does not depend on the ...
A review is made of the various brain imaging agents utilised in the post few years with their own characters and respective advantages: cerebral blood volume tracers, non diffusible tracers, diffusible tracers among which gases and lipophilic agents. Our results with IAMP and SPECT are presented in two different clinical application fields: normal pressure hydrocephalus and cerebral ischemia.
A review is made of the various brain imaging agents utilised in the post few years with their own characters and respective advantages: cerebral blood volume tracers, non diffusible tracers, diffusible tracers among which gases and lipophilic agents. Our results with IAMP and SPECT are presented in two different clinical application fields: normal pressure hydrocephalus and cerebral ischemia.
Scintigraphic imaging of dementia relies today essentially on the study of brain Single Photo Emission ComputedTomography (SPECT) perfusion, after intravenous injection of 99mTc radio-pharmaceutic. This paper is based on the guidelines published in October 2001 by the European Association of Nuclear Medicine (http://eanm.org/). (author)
70 patients with squamouscell carcinoma of larynx and hypopharynx were examined by computedtomography; the TNM staging of tumors by CT, by endoscopy and by surgical operation was reviewed. CT proved to be reliable both to recognize the presence of neoplasms, with the exception of those very superficial, and their deep spreading to preepiglottic and paralaryngeal spaces, to the soft tissues of the neck and to the cartilages. Therefore CT is the examination of choice in laryngeal neoplasms staging, because it precisely completes the clinical and endoscopical informations.
Cardiac tumours may display diverse symptoms through potential involvement of any structure of the heart. We describe a case of a highly malignant thymoma with involvement of different cardiac structures with important haemodynamic compromise. With the high sensitivity of transthoracic echocardiography for detection of intracardiac masses, computedtomography and magnetic resonance add essential structural preoperative information on the tumour and surrounding tissue as vessels, pleura, lung and mediastinum.
In developing new receptor-site specific brain imaging agents labeled with I-123 for single photon emission computedtomography (SPECT), an analog of raclopride, 3-["1"2"5I]-iodo-N-[(1-ethyl-2-pyrrolidinyl)-methyl]-2-hydroxy-6-me-thoxy benzamide (IBZM), was prepared using a method similar to that reported for raclopride and its derivatives. (author).
To optimize the emergency care of patients with multiple injuries, a special emergency room with integrated radiological equipment has been developed. It consists of a linear array of a computedtomography system, a mobile C-arm with an integrated scattered radiation grid for conventional films and a C-arm fluorographic system. The intent is to avoid delay caused by transport and repositioning of the patient. It enables all necessary diagnostic procedures to be performed within a minimal amount of time. (orig./MG).
A thermal neutron imaging facility for computedtomography and real-time neutron radiography is being developed at the University of Texas at Austin. The TRIGA reactor is a graphite-reflected Mark It pool-type research reactor. The neutron imaging facility will use beam port, which is at one end of a through part. Monte Carlo calculations were used to design the neutron collimator for this facility.
Distribution of Lipiodol within hepatic tumor was evaluated using serial computedtomography. Imagistic Lipiodol transition into the tumor via hepatic artery was slower than that of water soluble contrast medium, spreading to central part first and turn to peripheral part of the tumor. This method was thought to be useful to clarify Lipiodol distribution in hepatic tumor and to decide the method or necessity of additional trans-arterial therapy. (author).
Out of one hundred cases of the urinary bladder abnormalities examined by this method, CT staging and pathological correlations were investigated in 61 cases of the urinary bladder neoplasms. Accuracy of CT staging was 87% in this series with possible exception of 6 cases involving the bladder base and dome. CT scan using this method is the most reliable procedure to determine the treatment modalities of the urinary bladder tumors.
As a self-teaching tool, this illustrated guide facilitates home study of the complexities of thoracic CT's. Over 400 illustrations and accompanying copy are used to provide a basis for understanding the CT appearances of disease processes and a comparison of CT lookalikes. It updates new and interesting developments in the format of case presentations.
Intrahepatic cholangiocarcinoma is an uncommon tumor as primary hepatic neoplasm. Five cases of cholangiocarcinoma, mass forming peripheral type, are reported about its CT findings. They were manifested as a poorly marginated low density mass with a irregular stellate area. In one case, a cut section of the gross specimen following surgery showed a central callagenous scar and vessels within the necrotic tumor. (author).
A 21-year-old male patient was transferred to the emergency room of our hospital after suffering seat belt abdominal injury in a traffic accident. Abdominal computedtomography revealed a massive hematoma...Full Text Available
Helical tomotherapy presented many unique dosimetric challenges and solutions during the initial commissioning process, and some of them are presented. The dose calculation algorithm is convolution/superposition based. This requires that the energy fluence spectrum and magnitude be quantified. The methodology for doing so is described. Aspects of the energy fluence characterization that are unique to tomotherapy are highlighted. Many beam characteristics can be measured automatically by an included megavoltage computedtomography imaging system. This greatly improves data collection efficiency.
Computedtomography was performed on 5 patients with chronic cerebral paragonimiasis. CT showed solitary or multiple, amorphous, round, or oval calcifications, and ventricular enlargement in all 5 cases. A large low-density area is also found in 4 of the 5 cases. These CT findings are compatible with previously reported findings of simple X-ray films of the skull, pneumoencephalography, and pathological studies. (author).
Primary peritoneal malignant mixed mullerian tumors are very rare. We report the case of a patient presenting with pain in the right upper quadrant of the abdomen and in whom the physical examination demonstrated a peritoneal mass. Computedtomography (CT) confirmed the presence of a mass, with invasion of adjacent organs.
The authors present an unusual case of a patient with orbital metastases from renal carcinoma involving the extra ocular muscles bilaterally. The importance of computedtomography for the differential diagnosis with other orbital lesions is emphasized. (author)
An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computedtomography. (ERB)
To improve the detection rate of lung cancer, we have introduced low-dose CT and CR technique into a population-based annual mass screening. From December 1999, 3868 and 12618 individuals participated in this screening program with CT and with CR, respectively. Primary lung cancer was detected in 15 (0.39%) by CT and 8 (0.06%) by CR. This results show high detection rate of primary lung cancer as had been previously reported. (author)
A mathematical and physical model was constructed describing the hydrodynamics of the two-phase mixture in the horizontal steam generator. The HP 9830 A desk-top calculator was used for the computations. The output variable of the solution was the level shape. A quantitative and qualitative comparison was made of the results of computations and experimental data. (author).
Several computer assisted processing and display methods are evaluated using a series of 100 normal brain scintigrams, 50 of which have had single 'mathematical tumours' superimposed. Using a standard rating system, or in some cases quantitative estimation, LROC curves are generated for each method and compared. (author).
Study Type - Therapy (case series)Level of Evidence 4 OBJECTIVE To present our experience of retroperitoneoscopic partial adrenalectomy (RPA) for small adrenal tumours, as with modern imaging methods small adrenal lesions are being diagnosed more commonly, and retroperitoneoscopic adrenal surgery for small adrenal tumours (PATIENTS AND METHODS We retrospectively reviewed the records of 389 consecutive retroperitoneoscopic adrenalectomies from September 2005 to December 2008, 88 of which were small adrenal tumours and treated by RPA. Ultrasonography and computedtomography (CT) were used in all patients before RPA, and magnetic resonance imaging or positron emission tomography/CT in some patients. We used RPA for adrenal tumours and total adrenalectomy for adrenal cancer. During the surgery...
A thermal neutron imaging facility for real-time neutron radiography and computedtomography has recently been developed at the University of Texas TRIGA reactor. Extensive Monte Carlo design calculations were used to determine optimal design parameters of the neutron collimator system to avoid costly trial and error. Thermal neutron flux determined by gold foil activation is 5 {times} 10{sup 6} n/cm{sup 2}{center_dot}s at the primary imaging location with beam size of 22.5 cm in diameter. The collimation ratio can be varied from 125 to 235. The neutron-to-gamma ratio is 7.8 {times} 10{sup 6} n/cm{sup 2}{center_dot}mR. The facility has been tested for radiography and tomography applications and is now fully operational.
A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computedtomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.
Existing oil reservoirs might be more fully exploited if the properties of the flow of oil and water in porous media were better known. In laboratory experiments it is important to collect as much information as possible to make a descriptive model of the system, including position imaging and chemical binding information. This thesis develops nuclear methods for obtaining position image and chemical binding information from flow experiments of porous media. A combined positron emission tomography and single photon emission computedtomography system to obtain position images, and a time-differential perturbed angular correlation system to obtain chemical binding information, have been built and thoroughly tested. 68 refs., 123 figs., 14 tabs.
Bone mineral content as determined by computerized tomography (CT) and mechanical strength on axial loading were compared in 36 cadaveric femur specimens. Based on the CT measurements of density and area, the mass of a transverse slice of the femur was estimated. Highly significant correlations were demonstrated between strength and cancellous bone density. Even higher correlations were revealed when the bone masses of the proximal and distal femoral areas were calculated. Based on these findings, an equal distribution of the effective mass of the femur was postulated. This hypothesis was confirmed in an experimental rotational model. The CT attenuation values were also correlated to direct measurements of bone mineral content, i.e. calcium. Moreover, the strength of different metal implants, commonly used in femoral neck fractures, were assessed in cadaver specimens. 134 refs., 13 figs., 12 tabs.
Computedtomography (CT) has been incorporated in an industrial Diode-Array Digital Radiography (DADR) system. An input data size of 512 pixel points x 400 projections yielded a 400x400 output image matrix. Reconstruction algorithms used are the filtered backprojection (FBP) and the direct Fourier reconstruction (DFR). Various filters were used in the FBP reconstruction process and their effects on image quality were evaluated. A spatial resolution of 100 {mu}m was measured with a block of plates and a minimum detectable feature size in the range of 10-100 {mu}m was measured using thin wires. Industrial specimens imaged have included ceramic samples, ball bearings and integrated circuits. A number of engineering problems have been solved, such as adjustment of the X-ray source, centering of the rotator spindle in the view field and beam-hardening corrections. (orig.).
The simulation of processes in engineering and the physical sciences has progressed rapidly over the last several years. With rapid developments in supercomputers, parallel processing, numerical algorithms and software, scientists and engineers are now positioned to quantitatively simulate systems requiring many billions of arithmetic operations. The need to understand and assimilate such massive amounts of data has been a driving force in the development of both hardware and software to create visual representations of the underling physical systems. In this paper, and the accompanying videotape, the evolution and development of the visualization process in scientific computing will be reviewed. Specific applications and associated imaging hardware and software technology illustrate both the computational needs and the evolving trends. 6 refs.
Computer software for risks assessment of transportation of important freight has been developed. It incorporates models of transport accidents, including terrorist attacks. These models use, among the others, unput data of cartographic character. Geographical information system technology and electronic maps of an area are involved as an instrument for handling this kind of data. Fuzzy set theory methods as well as standard methods of probability theory have been used for quantitative risk assessment. Fuzzy algebraic operations and their computer realisation are discussed. One preliminary example of risk assessment is described. (authors)
The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computedtomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial ...
Computerized Tomography has gained an important role in the diagnosis of the complications of prosthetic surgery of the abdominal aorta: the importance of such complications come from their frequency, which is proportional to the increasing number of interventions, and their severity. The authors investigated the CT patterns of the most frequent complications. 24 patients referred for strongly suspected postoperative complications were examined in 2 years: fever and leukocytosis (20 cases) and progressive anemia (4 cases) were the most frequent findings. The operation had been performed 7#+-# 12 weeks before (2 patients were excluded because surgery dated less than 3 weeks. 14 patients had infective complications: thickening (57%) and inhomogeneity (43%) of the periprosthetic wrap and ectopic gas bubble (78%) were the most frequent Computerized Tomography findings. The authors also observed 2 periprosthetic hematomas, 1 aneurysm relapse and 1 ...
Skeletal radiotracer (sup(99m)Tc-HEDP) uptake was quantitated with and without the aid of a computer in 30 chronic dialysis patients with histologic evidence of renal osteodystrophy. Before scintigraphy, elevated soft-tissue activity due to the absence of renal radiotracer excretion was reduced by hemodialysis. The results were compared with those of a normal group and with the results of the biochemical and the bone morphometric studies of these patients. In all patients the radiotracer uptake was elevated, often markedly. In several patients with minimal histologic bone disease, however, soft-tissue activity could not be normalized by hemodialysis although its influence on the quantitative data could be further reduced (but not excluded) by computer evaluation of skeletal radiotracer uptake. Since the latter technique clearly distinguished the majority of the patients from the normals, it appears that ...
Skeletal radiotracer (sup(99m)Tc-HEDP) uptake was quantitated with and without the aid of a computer in 30 chronic dialysis patients with histologic evidence of renal osteodystrophy. Before scintigraphy, elevated soft-tissue activity due to the absence of renal radiotracer excretion was reduced by hemodialysis. The results were compared with those of a normal group and with the results of the biochemical and the bone morphometric studies of these patients. In all patients the radiotracer uptake was elevated, often markedly. In several patients with minimal histologic bone disease, however, soft-tissue activity could not be normalized by hemodialysis although its influence on the quantitative data could be further reduced (but not excluded) by computer evaluation of skeletal radiotracer uptake. Since the latter technique clearly distinguished the majority of the patients from the normals, it appears that ...
Through the dedicated collaborative efforts of many individuals interested in supporting local education, computer laboratories were established at two urban high schools. The purchasing and implementation of the project was handled by the Alliance for Education, a local non-profit education advocate. Funds were supplied by the Air Force as part of a 3-year research activity utilizing artificial intelligence technology to tutor 9th grade students. NCR (now AT7T Global Information Solutions) corporate leaders provided the computers and network equipment at a considerable savings to the project. Each lab is a state-of-the-art facility with air-conditioning, carpeting, special computer tables, computer projection screens, and on-site technical support. Student and teacher enthusiasm toward the project has been gratifying and quantitative results are currently being evaluated for both ...
The field of a digital-image processing has experienced dramatic growth and increasingly widespread applicability in recent years. Fortunately, advances in computer technology have kept pace with the rapid growth in volume of image data in these and other applications. Digital image processing has become economical in many fields of research and in industrial and military applications. While each application has requirements unique from the others, all are concerned with faster, cheaper, more accurate, and more extensive computation. The trend is toward real-time and interactive operations, where the user of the system obtains preliminary results within a short enough time that the next decision can be made by the human processor without loss of concentration on the task at hand. An example of this is the obtaining of two-dimensional (2-D) computer-aided tomography (CAT) images. A medical decision might ...
Abstract Crouzon syndrome is characterized by premature fusion of sutures and synchondroses. Recently, the first mouse model of the syndrome was generated, having the mutation Cys342Tyr in Fgfr2c, equivalent to the most common human Crouzon/Pfeiffer syndrome mutation. In this study, a set of micro-computedtomography (CT) scannings of the skulls of wild-type mice and Crouzon mice were analysed with respect to the dysmorphology caused by Crouzon syndrome. A computational craniofacial atlas was built automatically from the set of wild-type mouse micro-CT volumes using (1) affine and (2) non-rigid image registration. Subsequently, the atlas was deformed to match each subject from the two groups of mice. The accuracy of these registrations was measured by a comparison of manually placed landma...
A technique for quantitative analysis of growth plates in varus or valgus deformity about the knee has been developed. Computer-generated regions of interest are placed on magnification scintigraphs to divide distal femoral and proximal tibial physes into four equal segments. The ratio of counts in the medial half to counts in the lateral half was studied in 31 children (22 normal, 9 with angular deformity). Normal ratios were 0.74 to 0.98 for femora and 0.98 to 1.20 for tibias. In eight of nine patients with deformity, the ratio was abnormal; in two patients the ratio returned to normal when the deformity ceased to progress.
The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on the distance of the ...
The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on the distance of the ...
The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on the distance of the ...
Malignant tumors of the sinonasal cavities are rare and often diagnosed late in the course of the disease. These tumors can extend into regions such as the orbit and brain, where treatment is difficult. Ten patients with non treated sinonasal malignant neoplasms and radiological evidence of tumor extension into the orbit and brain were studied with computedtomography. Five (50%) tumors were epithelial neoplasms whereas squamous cell carcinoma was the most common type (3 cases). The ethmoidal sinus was the most common site of origin of the tumors (40%), followed by the maxillary sinus (30%) and nasal cavity (30%). A total of 16 orbits were involved since 6 patients (60%) had bilateral orbital involvement. The tumors extended more often into the orbits through erosion of the medial and inferior orbital bones. All orbital compartments were involved in the majority of the orbits. Tumoral extension into the cranial cavity was more common through ...
Correct ortopedic therapy for traumas of the cervical rachis requires perfect knowledge of the spatial balance of the fracture focus. The authors belive ComputedTomography (CT) to be the most suitable, and often indispensable, method for this purpose. Twenty-four patients were examined for traumatic pathology of the cervical rachis. In 7 cases with clinically minor traumas, the negative outcome of the traditional traumas, the negative outcome of the traditional exam was considered reliable and sufficient for therapeutic purposes. The extant 17 patients were examined also by means of CT, either to better dermine the characteristics of skeletal lesions already ascertained with traditional techniques or to asses the presence of clinically-suspected osteo-articular lesions, even with negative conventional X-rays. For 9 of these patients orthopedic treatment was considered sufficient, whereas 8 patients underwent surgery and were subsequently ...
To analyze and review the most common focal lesions of the external auditory canal (EAC), describing the computedtomography (CT) findings. The CT images of EAC were reviewed in a series of 167 patients. Abnormal findings were recorded in 13 cases. The CT images were correlated with otoscopic and/or intraoperative findings. There were four cases of osteoma (one located outside the EAC); all of which were treated surgically, as was the one case of exostosis. Six patients presented debris in EAC, coinciding with clinical evidence of external otitis. There were two cholesteatomas derived from EAC, one of them secondary to survery to treat osteoma. On patient was diagnosed as having a basal cell carcinoma of the ear, extending to EAC, but refused to undergo surgery. Five patients presented small triangular laminae of dense bone arising from the upper wall of the EAC which were defined as abnormal variants of the fusion of the temporal squamous ...
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computedtomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the reconstructed image. The image quality could be satisfactory to ...
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computedtomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the reconstructed image. The image quality could be satisfactory to ...
Purpose: To evaluate the diagnostic performance (colorectal lesions) of computedtomography (CT) colonography in 111 patients, a majority of whom were at high risk for colorectal neoplasia. Material and Methods: After bowel preparation, CT colonography was performed, immediately followed by conventional colonoscopy. The diagnostic performance of CT colonography was analyzed relative to lesion size, histological diagnosis, and diagnostic certainty. Results: The sensitivity of CT colonography increased with lesion size (P<0.001), and was 91% (21/23) for lesions > or = 10 mm. All 10 carcinomas and 86% (19/22) of adenomas > or = 5 mm were detected. Unconfirmed or false-positive CT findings were generally small and/or reported with low diagnostic certainty. The specificity of CT colonography would be 45% (30/66; 95% CI 34% to 57%) if patients with findings of any size and any diagnostic certainty were selected for follow-up, and ...
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computedtomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,{theta}) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computedtomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,#theta#) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.
The purpose was to compare the findings of multi-detector computedtomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Bjoerk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic valve replacements, two redo mitral replacements and one Amplatzer ductal occluder ...
Cerebral angiography, pneumoencephalography, and radioisotope brain scan with their differing diagnostic abilities have provided the neurologist and neurosurgeon with extremely valuable diagnostic techniques. It is doubtful, however, if any of these now conventional methods had the enormous impact on the practice of neurology that computer assisted axial tomography (C.A.T.) is beginning to have. Here, for the first time, is a test which, without significant risk or discomfort, can demonstrate some normal intracranial (and intraorbital) structures, can demonstrate some normal intracranial pathology and, in many cases, can make the potentially dangerous contrast studies unnecessary. After only a few months experience with C.A.T. in a clinical setting, it has become obvious that there will have to be a reappraisal of the accepted investigative work-up of many conditions. While it is too early to have formulated strict criteria for the use of ...
Forty-one cases of mediastinal tumor examined by computedtomography were reviewed. CT findings of the mediastinal malignancy were as follows: 1) inhomogeneous density on contrast CT, 2) equivocaton of fat plane surrounding the tumor, 3) irregular margin. Benign teratoma had smooth margin and included fat or calcification density. Mediastinal seminoma was observed as a lobulated mass with no calcification on CT. These findings were similar to the patterns of malignant thymoma or lymphoma. Consequently, it was very difficult to differentiate between malignant thymoma and malignant lymphoma by CT. According to our data, malignant thymoma tended to expand to only one side of the anterior mediastinum and to invade the anterior chest wall. On the other hand, malignant lymphoma of anterior medistinal type expanded into the trachea and the superior vena cava. In patients with sarcoidosis, the enlargement of bilateral hilar lymph nodes was commonly ...
As yet, the role of ComputedTomography (CT) as a routine imaging technique in the staging and follow-up of thoracic Hodgkin's disease has not been assessed. The authors reported the results obtained in 120 patients affected with thoracic Hodgkin's disease, staged and followed by means af chest X-rays and CT. CT better identified intrathoracic involvement of mediastinal nodes, of lung parenchyma, of pleura, and of pericarcial and chest walls in 54/120 patients (45%), with staging modifications in 18 (15%) of them only. Treatment was changed only in 12 patients (19%) where radiation therapy had been planned. The clinical value of the additional information yielded by CT was especially evident in the follow-up: CT allowed the correct evaluation of persistent/ recurrent disease in 51/117 patients (43.5%), a figure high enough to suggest the use of CT in the routive follow-up of patients affected with thoracic Hodgkin's disease.
The aim of this study was to assess the body weight-tailored contrast material injection protocol for 64-detector computedtomography (CT) to maintain optimal coronary CT attenuation. A total of 60 patients who underwent CT coronary angiography were assigned to one of three groups: protocol A, total of 0.7 ml kg"-"1 with 300 mg I/ml iodine concentration; protocol B, total of 0.6 ml kg"-"1 with 350 mg I/ml; protocol C, total of 0.7 ml kg"-"1 with 350 mg I/ml. The injection duration was 10 s in all patients. The proportion of intracoronary attenuation values >325 Hounsfield unit (HU) was compared on a per-vessel and per-patient basis. The attenuation value was significantly more likely to exceed 325 HU with protocol C (95% for reader 1 and 90% for reader 2) than with protocol A or B on the per-vessel analysis (P325 HU) with 64-detector CT when using an injection duration of 10 s. (author)
Twenty-five patients with ovarian carcinoma who had been operated and treated with chemotherapy underwent clinical examination and CT before reintervention (second-look laparotomy) to detect the presence of eventual recurrences. The prediction of recurrence based on CT and clinical findings was compared with the surgical findings at reintervention. CT proved to be more accurate than clinical examination in detecting recurrences; this was especially true for masses in the abdominal cavity, with the exception of small peritoneal nodules. The authors suggest the use of CT for staging the patients candidate to reintervention. This might help to avoid reintervantion in patients with persistent disease and to plan treatment.
The aortovenous fistulas are rare, most of them are aortocaval fistula. The non-caval communication of the fistula is sparse. Herein we report a 47-year-old female diagnosed as traumatic aorto-superior mesenteric vein (Ao-SMV) fistula. The abdominal pain, fullness, and frank bruit on abdominal auscultation suggested the diagnosis of an intra-abdominal arteriovenous fistula. The diagnosis of Ao-SMV was further confirmed by the computedtomography (CT) and aortography. The fistula was successfully treated with transcatheter coil embolization. This is the first case of Ao-SMV fistula. It provides an alternative option of treatment other than conventional surgery. PMID:19327940
As a consequence of the expanded use of long term hemodialysis and continuous ambulatory peritoneal dialysis (CAPD) treatments and extended life spans, complications of end-stage renal disease and dialysis treatments are being encountered with increasing frequency in these patients. Computedtomography can accurately depict many of the potential complications of end-stage renal disease on dialysis. This article presents the abdominal CT findings of 429 end-stage renal disease patients who are on either hemodialysis or continuous ambulatory peritoneal dialysis treatment.
The US study of the posterior compartment of the knee usually allows the clinical suspicion of popliteal cyst to be confirmed. Neverthless, in case of giant Baker's cysts - which are, at any rate, less frequent -US diagnosis is more difficult. CT can help determine the benign nature of the lesion, and hallow an accurate spatial evaluation. Moreover CT, when accurately performed, demonstrates the caudal or cranial cystic spread, together with its clear separation from adjacent muscular tissues. Direct coronal scans are more useful to obtain better spatial definition than reformatted images.
Roentgenological analysis of the anterior chest wall was performed in twenty six patients with sternocostoclavicular hyperostosis. Initial hyperostotic change was seen at the first costosternal junction with ventral protrusion. Hyperostosis gradually developed around the first ribs, and irregular hyperostotic changes were also seen along the costoclavicular ligaments. Even in the final stage, however, sternoclavicular joint spaces were well preserved. These findings suggest that sternocostoclavicular hyperostosis is a disorder initiated around the costal cartilage including the periosteum and perichondrium, and that arthritis is not a condition stemming from that disorder.
Radiological findings of chest and abdominal wall involvement in Hodgkin's disease are reported. This manifestation was diagnosed in one patient in the primary staging and in two patients during the course of the disease. Typical radiological findings are soft tissue masses in the chest and abdominal wall, in two cases with continous tumor growth of enlarged mediastinal lymphnodes into the anterior chest wall. The axial computedtomography is the best method to evaluate the extent of chest and abdominal wall involvement in Hodgkin's disease.
Single photon emission computedtomography (SPECT) of lung perfusions permits to map functioning lung parenchyma with higher sensitivity than CT. Delivering higher radiations doses it used to increase local control in lung carcinoma; this strategy is based on radiobiological and clinical studies. Lung parenchyma is a dose-limiting tissue in patients irradiated for lung cancer. Functional mapping based on SPECT and CT findings permits to design radiation beams such as to minimize irradiation of functioning lung.
A neutron collimator system is being designed as part of a neutron imaging facility for computedtomography and real-time neutron radiography research at the through beam port of the University of Texas TRIGA reactor. Lack of sufficient information about collimator systems in a through port from the literature necessitated the use of Monte Carlo calculations using the MCNP code 3 to search for optimal design configuration and materials that maximize the thermal neutron intensity at the image plane while minimizing the fast neutrons and gamma radiation.
Twenty rheumatoid arthritis (RA) patients with involvement of the cranio-cervical junction (CCJ) were given CT scan. In most cases the myelo-CT technique with the lumbar injection of small quantities of non-ionic contrast medium was adopted; CT easily diagnosed the horizontal and vertical dislocations on the CCJ, the bone strcture lesions and the inflammatory masses. A high frequency of medullary compressions was also found in these patients. Myelo-CT appears to be the technique of choice for the precise definition of the various factors responsible for the neurological complications found in RA of the CCJ.
A 37-year-old military mechanic presented to our institution with a chronic history of a slowly enlarging left elbow antecubital fossa mass. There was no history of other chronic illness or trauma. Magnetic resonance imaging (MRI) and excisional biopsy revealed fatty villi and synovial inflammation within the left bicipitoradial bursa, consistent with lipoma arborescens. Four years later the patient presented with a 6-month history of swelling at the antecubital fossa of the opposite elbow. Diagnostic computedtomography and MRI examinations were performed. The surgical and pathologic findings confirmed the imaging diagnosis of lipoma arborescens at the right bicipitoradial bursa. (orig.)
Purpose. To validate a protocol for creating virtual models to be used in the construction of solid prototypes useful for the planning-simulation of maxillo-facial surgery, in particular for very complex anatomical and pathologic problems. To optimize communications between the radiology, engineering and surgical laboratories. Methods and materials. We studied 16 patients with different clinical problems of the maxillo-facial district. Exams were performed with multidetector computedtomography (MDCT) and single slice computedtomography (SDCT) with axial scans and collimation of 0.5-2 mm, and reconstruction interval of 1 mm. Subsequently we performed 2D multiplanar reconstructions and 3D volume-rendering reconstructions. We exported the DICOM images to the engineering laboratory, to recognize and isolate the bony structures by software. With these data the solid prototypes were generated using ...
The purpose of this study was to use high-resolution magnetic resonance (MR) imaging combined with image analysis to investigate the three-dimensional (3D) trabecular structure, anisotropy, and connectivity of human vertebral, femoral, and calcaneal specimens. The goal was to determine whether: (a) MR-derived measures depict known skeletal-site-specific differences in architecture and orientation of trabeculae; (b) 3D architectural parameters combined with bone mineral density (BMD) improve the prediction of the elastic modulus using a fabric tensor formulation; (c) MR-derived 3D architectural parameters combined with BMD improve the prediction of strength using a multiple regression model, and whether these results corresponded to the results obtained using higher resolution depictions of trabecular architecture. A total of 94 specimens (12 x 12 x 12 mm cubes) consisting of trabecular bone only were obtained, of which there were 7 from the calcaneus, 15 from distal femur, 47 from the ...
Chest computedtomography (CT) was valuable in detecting extrinsic tracheal compression by mediastinal masses in two pediatric patients. This prompted an independent evaluation by CT of 14 children with masses involving the middle mediastinum and possible intrathoracic tracheal narrowing. Computer programs permit precise calculation of tracheal cross-sectional areas. Any apparent decrease in tracheal area may be compared with CT-derived data in normal children. Chest CT not only demonstrates the presence of extrinsic airway compression in pediatric patients with mediastinal masses, but also is capable of precisely measuring the extent of this narrowing. This method identifies children at potential risk for respiratory compromise and may aid in subsequent therapy.
Twenty-two out of 31 patients with chronic renal failure and secondary hyperparathyroidism who underwent parathyroidectomy before operation underwent non-invasive image diagnosis of parathyroid glands by computedtomography (CT), scintigraphy with /sup 201/TlCl and /sup 99m/TcO/sup 4 +/, and/or ultrasonography. CT visualized 39 of 45 parathyroid glands (86.7%), weighing more than 500 mg. Scintigraphy with a subtraction method using a computer performed the diagnosis in 19 of 27 glands (70.4%). Ultrasonography detected 21 of 27 glands (77.8%). Image diagnosis was also useful in the postoperative follow-up study. The non-invasive image diagnosis of parathyroid glands in patients with chronic renal failure is thus valuable for 1) definite diagnosis of secondary hyperparathyroidism, 2) localization, and 3) diagnosis for effectiveness of conservative treatment.
In a retrospective study of 21 patients, in whom the acetabular fractures were suspected on initial radiographs, we compared and analysed the computed tomographic findings and plain radiographic findings. The results were as follow: 1. In patients with multiple trauma, no further change in position was required during CT examinations. 2. CT showed intraarticular loose bodies, which were invisible on plain radiographs. 3. CT was useful in detecting the fractures of acetabular rims, medial wall of acetabulum, and femoral head. 4. CT permitted better evaluation of shape, extent, and degree of separation of fracture fragments. 5. CT was helpful in detecting the associated fractures and soft tissue injuries. 6. CT also demonstrated the adequacy of reduction, the position of metallic fixation devices, and the presence or absence of remaining intraarticular osseous fragments after surgery.
In Niigata University Hospital, most of conventional radiography were changed to Fuji computed Radiography (FCR) from July 1988. To evaluate its clinical utility, questionnaires relating to FCR image were distributed to all physicians including non-radiologists in the hospital after three months. The ratio of the physicians evaluated FCR image to be better than conventional image was 75% in chest radiography, 64% in abdominal radiography. FCR tomography of bone, joint, cranium and chest was also evaluated to be better than conventional by most of the physicians. Reduced size of the film and difficulty in detecting interstitial shadows of the lung were mentioned to be the fault of FCR. (author).
In Niigata University Hospital, most of conventional radiography were changed to Fuji computed Radiography (FCR) from July 1988. To evaluate its clinical utility, questionnaires relating to FCR image were distributed to all physicians including non-radiologists in the hospital after three months. The ratio of the physicians evaluated FCR image to be better than conventional image was 75% in chest radiography, 64% in abdominal radiography. FCR tomography of bone, joint, cranium and chest was also evaluated to be better than conventional by most of the physicians. Reduced size of the film and difficulty in detecting interstitial shadows of the lung were mentioned to be the fault of FCR. (author).
A chemical equilibrium model is used, implemented in a compact FORTRAN package called HITEQ, to investigate possible mineral deposition related to prereinjection treatment of Cerro Prieto brines for silica removal. Large saturation ratios of the treated brines with respect to several minerals are indicated by these computations. As a remedy, an inexpensive CO/sub 2/ removal scheme aimed at inhibiting carbonate mineral precipitation is proposed. This scheme is quantitatively discussed with the aid of HITEQ. It is concluded that the proposed treatment is both technically and economically feasible.
To make a quantitative comparison of risks between the SNR 300 and a modern PWR (Biblis B), the consequences of an accident or the extent of damage of a release of radionuclides to the environment due to an accident are estimated by computer programs for accident consequence models. The accident analysis includes an analysis of events for Bethe-Tait accidents with failure of the outer containment. The FGSB release rates are compared with those of the Society for Reactor Safety (GRS). (HP).
We compute the potential for localized closed string tachyons in bosonic string theory on the orbifold C/Z{sub 4} using level-truncated closed string field theory. The critical points of the potential exhibit features which agree with their conjectured identification as lower-order orbifolds. However this case also raises some questions regarding the quantitative predictions associated with these conjectures. (author)
A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10/sup 11/ m/(m/sup 2/-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83/sup 0/C +/- 8/sup 0/C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3/sup 0/ +/- 0.1/sup 0/ thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the simultaneous iterative reconstruction technique (SIRT) and the ...
A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10"1"1 m/(m"2-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83"0C +/- 8"0C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3"0 +/- 0.1"0 thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the simultaneous iterative reconstruction technique (SIRT) and the convolution method, were ...
Computer software for risk assessment of transportation of important freight has been developed. It incorporates models of transport accidents, including terrorist attacks. These models use, among the others, input data of cartographic character. Geographic information system technology and electronic maps of a geographic area are involved as an instrument for handling this kind of data. Fuzzy set theory methods as well as standard methods of probability theory have been used for quantitative risk assessment. Fuzzy algebraic operations and their computer realization are discussed. Risk assessment for one particular route of railway transportation is given as an example. (author)
Complex abdominal lesions include a variety of pathologies, such as septated, infected, and hemorrhagic cysts, abscesses, tumors, and fluid collections of different ethiology. These lesions present diagnostic difficulties with both Ultrasonography (US) and ComputedTomography (CT), since findings may not be present or, when present, are not specific. Keeping these limitations in mind, we evaluated 105 patients (111 abdominal lesions) with both US and CT in order to compare their adequacy in predicting the nature of the lesion. On the basis of US and CT results, complex abdominal lesions were divided in four classes: class I includes 43 cases in which both examinations gave the same contribution to the definition of the nature of the lesion, class II (14 lesions, mainly sperimentated cysts), in which US was superior to CT, class III includes 45 cases of hemorrhagic cysts, abscesses, fluid collections and, less frequently, cystic tumors; class IV ...
Tridimensional localization of bone and soft tissue injuries in complex facial trauma is fundamental for treatment. The face can be conceptualized as 3 groups of interconnected osseous struts that are oriented in the horizontal, sagittal and coronal planes. Each group of struts is closely related to specific soft tissue structures that are susceptible to injury. Any single CT section in the coronal plane or in the axial plane contains parts of one or more these struts. Facial CT in biplane were performed in 32 patients of facial trauma. The most common site of facial fractures is found in middle part of horizontal struts, geometrically in anteromedial portion of the inferior orbital fissure of the face. The most common soft tissue injury combined with facial fracture is hematoma and/or herniated orbital contents into the maxillary sinus. The serious combined soft tissue injuries were ocular rupture, retroorbital hematoma and optic nerve injury resulting blindness. CT was superior to ...
The introduction of positron emission tomography (PET)/magnetic resonance (MR) systems into medical practice in the foreseeable future may not only lead to a gain in clinical diagnosis compared to PET/computedtomography (CT) imaging due to the superior soft-tissue contrast of the MR technology but can also substantially reduce exposure of patients to ionizing radiation. On the other hand, there are also risks and health effects associated with the use of diagnostic MR devices that have to be considered carefully. This review article summarizes biophysical and biological aspects, which are of relevance for the assessment of health effects related to the exposure of patients to both ionizing radiation in PET and magnetic and electromagnetic fields in MR. On this basis, some considerations concerning the justification and optimization of PET/MR examinations are presented - as far as this is possible at this very early stage. ...
The seismic reflection exploration technique which is one of the geophysical methods for oil exploration became effectively to image the subsurface structure with rapid development of computer. As a tool to perform seismic inversion, seismic forward modeling program using ray tracing should be developed. In this study, we have developed the algorithm that is to calculate the travel time of the complex geological structure using ray tracing by subdividing the geologic model into triangular element (finite element) having the constant velocity. We can analytically calculate Jacobian with some information by this current ray tracing. With this Jacobian, we will develop new algorithm which is to obtain geological properties and to image the subsurface. Since the FEM (Finite Element Method) ray tracing we have developed goes well the inverse velocities structure, we can apply the inversion problem to complex geological model. This report consists of 3 articles. 1) ...
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray ComputedTomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray CT technique. (orig.).
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray ComputedTomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray CT technique. (orig.).
In order to improve the image quality of linear tomography performed with the Fuji Computed Radiography (FCR) system, we have examined one-dimensional unsharp mask filtering to reduce blur formed in the direction of tomographic swing. We determined a mask size and a weighting factor of the image processing suitable to obtain a quality tomogram. The mask size of 41 x 1 pixels for a 14 x 14'' imaging plate, which modifies the original image date and results in demonstrating a peak frequency at 0.2 cycles/mm for spatial frequency spectrum, is superior in showing fine vessel structures and morphological features of pathology in the lung fields. An additional spatial frequency filtration in the direction perpendicular to the tomographic movement reduces the blur and clearly demonstrates object contours running parallel to the tube movement. However, the additional filtration increases the appearance of noise on the processed image ...
Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI ...
Introduction: There are many problems in the radiological diagnosis of aseptic loosening in total hip arthroplasty. Computedtomography (CT) and magnetic resonance tomography (MRT) are not usable for metallic implants (stainless steel, cobalt alloy, titanium alloy). Material and Methods: From April 1993 to December 1993 15 CFRP non-cemented hip prostheses have been implanted. In a prospective clinical study plane radiographs, CT and MRT have been analysed. Results: Three stems were revised (1 femoral fracture, 1 severe thigh pain, 1 aseptic loosening). CFRP are not visible in plane radiographs. There was a complete (two-third of the cases) or nearly complete (one-third of the cases) small sclerotic interface between the prosthesis and the bone, these were apparent in CT and MRT in stable implant cases and did not have any clinical correlations. Discussion: The small sclerotic interface is quite different in comparison to so ...
Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localization of abnormalities. The resulting correlation of the anatomical and functional images may clarify the nature of the abnormality and help diagnose or stage the underlying disease. Whereas successful image fusion software has been developed for the brain, only limited success has been achieved for image alignment in other parts of the body. The development and current status of alternative approaches are presented. Dual-modality imaging is described with devices where two modalities are combined and mounted in a single gantry. The use of existing scanner technology ensures that no compromises are made in the clinical efficacy of either the anatomical or functional imaging ...
Integration of positron emission tomography (PET) and magnetic resonance (MR) has become a topic of increasing interest to the imaging community over the past two years. In this text, the authors attempt to distinguish facts from fiction concerning such integrated systems. Analysis of existing information of combined imaging on existing brain PET/MR systems and imaging experience with PET-computedtomography (CT) is reviewed. Various types of system integration of PET and MR are discussed with completely independent systems on one hand and completely integrated systems with the possibility of simultaneous data acquisition on the other hand. Furthermore, it is discussed, what simultaneous data acquisition with nuclear imaging systems combined with MR or CT really means, as technical simultaneity may not be relevant in light of the pharmacokinetics of the nuclear tracers used. The authors conclude that combining PET/MR is an ...
To evaluate the role of positron emission tomography-computedtomography (PET-CT) in staging and determining early treatment response to chemotherapy in children with neuroblastoma (NB) and its correlation with the final outcome. Patients and Methods: Seventeen patients of NB with mean age of 51.5 months (age range 2-132 months; 14 males, 3 females) underwent serial "1"8F-fluorodeoxyglucose (FDG) PET-CT imaging. All 17 patients were for staging before any treatment. Twelve of 17 patients underwent "1"3"1I meta-iodobezylguanidine (MIBG) scan and bone scan. MIBG uptake was seen in the primary lesion in 11/12 patients. MIBG uptake in bones was seen in 3/12 patients. All bone lesions were concordant on MIBG and bone scan. Early response to chemotherapy was evaluated after two cycles using PET-CT. A 30% reduction in longest diameter was taken as cut-off value for response on CT based on the response evaluation criteria in solid tumors criteria. ...
Purpose/Objective: With the advent of computedtomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A ...
Quantitative hepatic scintiangiography was previously used for evaluating the relative contribution of hepatic arterial and portal venous blood flows to the hepatic circulation. The present study compares 3 different procedures (automatic and manual integration, and slope fitting methods) for analyzing the hepatic time activity curves obtained after bolus i.v. injection of 370 MBq /sup 99m/Tc-diethylentriaminopentacetic acid. Twenty five subjects were studied: Five controls, ten cirrhotics, and ten portal hypertensive patients previously submitted to side to side portacaval anastomosis. The correspondence between results given by the different methods was satisfactory only in shunted patients, and the reproducibility of computed parameters was quite poor for all procedures. Accordingly, none of the methods can be considered as supporting reliable quantitative pathophysiological evaluations. However, the hepatic ...
The use of magnetic resonance imaging for diagnosis and the preoperative staging of renal cell carconoma was evaluated in 79 patients with 88 tumors. Gradient-echo and spin-echo images before and after intravenous administration of Gadolinium DTPA were compared with the results of computedtomography (CT) and histologic staging. The two imaging techniques had comparable results: T-stage was predicted correctly with CT in 78%.4% and with MRI in 84.0% of the cases, while the N-stage was accurately assessed in 81.8% and 79.5%, respectively. MRI had some advantages in diagnosing perirental tumor spread and in excluding an infiltration beyond Gerota's fascia. Therefore, MRI is a true alternative to CT for staging large renal cell carcinomas and especially for patients with contraindications for iodinated contrast agents. (orig.).
Radio-frequency catheter ablation (RFCA) of the distal pulmonary veins is increasingly being used to treat recurrent or refractory atrial fibrillation that doesn't respond to pharmacologic therapy or cardioversion. Successful RFCA of atrial al fibrillation depends on the pre-procedural understanding of the complex anatomy of the distal pulmonary veins and the left atrium. Aim of this parer is to describe the technical main features that characterise the multidetector helical computedtomography in the evaluation of this anatomic region before and after RFCA procedure. The 3D post-processing techniques useful for pre-RFCA planning are straightforward.
Background Computedtomography (CT) and magnetic resonance (MR) imaging can help diagnose benign adrenal adenomas, but prior studies rely on nonoperative follow-up as proof of a lesion?s benign nature. We examined adrenalectomy tissues to determine if imaging characteristics correlate with histopathologic findings. Methods We retrieved data for 196 consecutive adrenalectomies in 192 patients from 2000 to 2008. Imaging results were considered to signify benign adrenal adenoma if one or more of the following was present: Hounsfield units 60% or relative contrast washout of >40%, or MR with chemical-shift imaging demonstrating loss of signal intensity on out-of-phase images. Results The sensitivity and specif...
The aims of this study were to quantify the severity and extent of subclinical interstitial lung disease as depicted on HRCT and to study the relationship between the patterns of lung disease quantified by HRCT and the functional parameters and bronchoalveolar lavage findings in patients with rheumatic diseases. The results confirm that HRCT is a sensitive tool in detecting interstitial lung disease in patients with rheumatic diseases with no signs and symptoms of pulmonary involvement. The relationship between the different HRCT patterns and bronchoalveolar lavage cell profiles can identify patients at higher risk of developing irreversible lung fibrosis. A long-term, prospective follow-up study is needed to determine whether these patients will develop over pulmonary disease.
In spite of the improved imaging techniques currently available, mortality for pancreatic cancer is still high, and pancreatics is often diagnosed only in its advanced stages. The authors investigated the value of different imaging techniques - i.e., US, CT, and ERCP - for an early diagnosis, when a more effective (curative?) treatment can be suggested. Fifty-six cases of pancreatic cancer and 36 cases of chronic pancreatitis were evaluated. The results indicate that ERCP, with the help of statistical methods, is superior to US and CT not only in evaluating early neoplastic or inflammatory lesions, but also for their differential diagnosis. In the letter case, ERCP can sometimes be used as a valid alternative to fine-needle aspiration biopsy.
For neutron radiography (NR), photographic techniques have been mainly used for many years. To observe a dynamic event and to test many samples, the real-time neutron radiography (i.e. neutron television - NTV) system has been introduced at the E-2 experimental tube of the Kyoto University Research Reactor (KUR). The NTV system has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuel, to investigation of moving objects and to neutron computedtomography (NCT). New approaches using some advanced neutron converters, a high sensitive and resolution TV camera and a high performance image processing system are being undertaken for standard indicators, visualization on air-water two-phase flow, NCT and so on. (author).
In developing new brain imaging agents for single photon emission computedtomography (SPECT), we synthesized eleven radioiodinated phenoxyacetic acid derivatives and investigated the relationship between the chemical structure and in vivo characteristics. Biodistribution studies in mice revealed high initial brain uptake for all the compounds. Blood radioactivity level depended markedly upon the chemical stability of the compound. The alpha,alpha-dimethylester derivative, amide derivatives and diamine derivatives, which were stable to hydrolysis, showed low blood activity levels following intravenous administration. Disappearance of the ester and amide compounds from the brain was rapid. However, the diamine derivatives displayed improved retention in the brain. Compounds 3a and 4 possessed the best combination of high brain uptake and sufficient retention to be useful as potential brain imaging radiopharmaceuticals with SPECT devices.
A series of four 125I-labeled 1-substituted-4-phenylpiperazines were prepared and evaluated in rats as potential brain imaging agents. The compounds were labeled using (125I)iodide/chloramine-T or iodine monochloride and isolated in 48-60% radiochemical yields. The tissue distribution studies indicated that a butyrophenone derivative demonstrated the best overall brain-imaging properties. Compared with the compounds having other 1-substituents this agent had a more prolonged retention of activity in the brain and higher brain-to-blood ratios over the 4-h period studied. The in vivo behavior of this agent is comparable to that of radioiodinated N-isopropyl-p-iodoamphetamine, and, because it can be labeled directly via electrophilic methods, it has substantial potential for use in brain imaging with single photon emission computedtomography.
Computedtomography (CT) of the neck and mediastinum was performed in 16 patients with renal osteodystrophy. Thirty out of 34 excised parathyroid glands weighing more than 500mg were diagnosed preoperatively (88.2%). Scintigraphy of the neck with _2_0_1TlCl and sup(99m)TcOsub(4-) was also performed in 15 patients. The introduction of subtraction method with a mini-computor in the scintigraphy has remarkably improved the visualization rate of parathyroid glands. Ultrasonic echography (US) of the neck which is able to obtain not only transverse butalso longitudinal imaging was done in 7 patients. It has about same detection rate of the glands with CT. The visualization of enlarged parathyroid glands is valuable not only for localization but also for undeniable evidence of hyperparathyroidism. Also, repeated follow-up examination can determine the effectiveness of conservative treatment. (author).
The use of nondestructive evaluation (NDE) methods is proposed for characterization of transuranic (TRU) waste stored at the Radioactive Waste Management Complex. These NDE methods include real-time x-ray radiography, real-time neutron radiography, x-ray and neutron computedtomography, thermal imaging, container weighing, visual examination, and acoustic measurements. An integrated NDE system is proposed for characterization and certification of TRU waste destined for eventual shipment to the Waste Isolation Pilot Plant in New Mexico. Methods for automating both the classification waste and control of a complete nondestructive evaluation/nondestructive assay system are presented. Feasibility testing of the different NDE methods, including real-time x-ray radiography, and development of automated waste classification techniques are covered as part of a five year effort designed to yield a production waste characterization system.
A 46-year-old man was referred to us after he presented to his local physician complaining of difficulty eating. Upper gastrointestinal endoscopy revealed a tumor at the esophagogastric junction (EGJ), and moderately differentiated adenocarcinoma was diagnosed from the biopsy findings. Computedtomography (CT) showed apparent enlargement of the pretracheal lymph nodes, the lymph nodes around the bilateral recurrent laryngeal nerves, and the lower thoracic paraesophageal lymph nodes, confirming metastasis. Since the disease was far advanced esophagogastric cancer with marked lymph node metastases throughout the mediastinum, curative resection would have been unlikely. Thus, he was commenced on systemic chemotherapy with cisplatin (90 mg/body, day 8) + S-1 (120 mg/body/day, given for 3 weeks...
Abstract Introduction: Transduodenal ampullectomy (TDA) can be performed for benign and premalignant tumors of the ampulla of Vater (AOV) as an alternative to pancreaticoduodenectomy. However, the laparoscopic approach has rarely been attempted. In this report 2 cases of benign ampullary tumor that were treated by totally laparoscopic TDA. Patients and Methods: Case 1 was of a 75-year-old female who was admitted with left knee pain and underwent arthroscopic debridement. On postoperative day 6, she showed elevated levels of alkaline phosphatase, aspirate aminotransferase, alanine transaminase, and gamma-glutamyl transpeptidase, without any other laboratory test abnormality. She had no complaint of abdominal pain, and physical examinations were unremarkable. Computedtomography (CT), magnet...
There are many differences between industrial CT and industrial radiography, such as imaging principle, inspection time, radiation dose and the requirements for operators etc. The national standards for radiation protection of industrial detection are not applicable to the requirements of protection and safety for #gamma#-ray industrial CT to some extent now. In order to standardize the production and use for #gamma#-ray industrial CT, protect the safety of operators and the public, and to promote the popularization and application of #gamma#-ray industrial CT, it is significant to establish the national standards for radiation protection of #gamma#-ray industrial CT as soon as possible. The purpose of this paper is to introduce the contents of this standard, and specify some important terms. Then there is a brief discussion on the existing problems during establishing such standards. At last, the paper summarize the practice of the standards passed over the past one year, which ...
Abstract Studies of the megamouth shark, one of three planktivorous sharks, can provide information about their evolutionary history. Megamouth shark feeding has never been observed in life animals, but two alternative hypotheses on biomechanics suggest either feeding, i.e., ram feeding or suction feeding. In this study, the second moment of area of the ceratohyal cartilages, which is an indicator of the flexural stiffness of the cartilages, is calculated for 21 species of ram- and suction-feeding sharks using computedtomography. The results indicate that suction-feeding sharks have ceratohyal cartilages with a larger second moment of area than ram-feeding sharks. The result also indicates that the ram-suction index, which is an indicator of relative contribution of ram and suction behavi...
Particle accelerators are constructed and operated for a wide variety of applications. In particle physics - the branch of physics that studies the elementary constituents of matter and forces between them - high energy accelerators are used to look deep into the structure of matter. Medical particle accelerators are used for example in medicine to treat tumours [31], in imaging techniques such as Positron Emission Tomography (PET) [24], or for the radio-isotopes production. They also serve in many other industrial branches, e.g. geology, radiocarbon dating [39], molecular complex spectroscopy, lithography, food preservation etc. The eld of accelerator technology draws knowledge and expertise from a wide range of scientic disciplines and uses the latest technical knowledge. The incomplete list of covered disciplines includes mathematics, physics, electronics, computing, electromagnetic eld technology, microwave technology, cryogenics, vacuum ...
A 65-yr-old female developed cough, fever and dyspnoea following repeated exposure to a home ultrasonic humidifier. High-resolution computedtomography showed ground-glass opacity in both lung fields. Arterial blood gas analysis gave an oxygen tension of 8.38 kPa (63 Torr). Pulmonary function testing revealed restrictive ventilatory impairment with a reduction in the diffusing capacity. The diagnosis of extrinsic allergic alveolitis (EAA) was confirmed by radiographic findings, pathological evidence of alveolitis and reproductive development by a provocation test to the humidifier water. The yeast Debaryomyces Hansenii was the only microorganism cultured from the water of the humidifier. The double diffusion precipitating test and lymphocyte proliferative response was positive for an extract of D. Hansenii, providing evidence to incriminate this fungus. This is the first described case of EAA caused by D. Hansenii. PMID:12449192
Two cases of focal nodular hyperplasia (FNH), in which ultrasound (US), computedtomography (CT), and magnetic resonance imaging (MR) studies detected an atypical hemorrhagic pattern associated with an intrahepatic arterio venous malformation (AVM) around the growths, are presented. In both cases, histology demonstrated a very early regenerative stage and necrotic-hemorrhagic areas within the lesions. In these cases, the analysis of radiological findings, surgical specimens and histology seemed to confirm the pathogenetic hypothesis suggested by Wanless: in normal liver parenchyma, a ``blood steal`` phenomenon due to congenital or acquired intrahepatic AVM could cause ischemic damage, appearing as a hemorrhagic necrotic area, the extent of which depends on the degree of residual portal supply. (orig.)
The growth of a middle ear cholesteatoma behind a normal tympanic membrane is a rate though possible event. In such cases, CT may provide useful information for diagnosis. The results are presented of a CT study carried out on 14 patients affected with unilateral conductive hearing loss and with normal tympanic membrane. CT allowed the diagnosis of meddle ear cholesteatoma to be made in all cases. All patients were treated with surgery: 8 of them underwent tympanoplasty and 6 explorative tympanotomy. While the diagnosis of cholesteatoma was confirmed in 13 patients, in 1 case tympanosclerosis was diagnosed. CT diagnosis of middle ear cholesteatoma is based on the demonstration of a low-density soft-tissue mass, in association with bone erosion or ossicular dislocation. The author emphasizes the difficulty of a CT diagnosis of cholesteatoma in the patients with middle ear soft-tissue masses in the absence of bone alterations.
One of the goals of the DARPA Virtual Soldier Project is to aid the field medic in the triage of a casualty. In Phase I, we are currently collecting 12 baseline experimental physiological variables and a cardiac gated ComputedTomography (CT) imagery for use in an prototyping a futuristic electronic medical record, the "Holomer". We are using physiological models and Kalman filtering to aid in diagnosis and predict outcomes in relation to cardiac injury. The physiological modeling introduces another few hundred variables. Reducing the complexity of the above into easy-to-read text to aid in the triage by the field medic is the challenge with multiple display solutions. A description of the possible techniques follows. PMID:15718701
Brain tumor was diagnosed by computertomography or magnetic resonance imaging in 100 children aged 0 to 19 years. They consecutively underwent primary surgical treatment during the years 1984 to 1988. Non-neoplastic lesions and operations for residual tumors are not included. 54 tumors were localized supratentorially. 72% of these were benign og low grade malignancies. 46 tumors had an infratentorial localication. 59% of these were high grade malignancies. Children tolerate major-neurosurgical procedures better than adults and restitution is usually favourable. 42 children with high grade malignancies underwent postoperative radiotherpy. Per- and postoperative mortality in this series was 1%. 80 children are alive. 62 of these are in excellent condition after a median observation time of 40 months. 10 refs.
Colerectal cancer (CRC) is the second commonest cancer in the Western World. Successful treatment relies significantly on accurate detection and staging of primary disease as well as the early identification of the presence and extent of recurrence. Morphological imaging techniques, particularly computedtomography (CT), are well established and widely available to carry out these tasks in addition to predicting and monitoring response to therapy. This review analyses the current inadequacies for imaging CRC and critically assesses the potential role of functional imaging with positron emission tomography (PET). It was reviewed the current literature, to use the experience from the firs 1000 PET studies carried out at the institution and the perspective of surgical colleagues. It was found little evidence for the use of 2-["1"8F]fluoro-2-deoxy-D-glucose (FDG)-PET for screening asymptomatic individuals and current modalities ...
The seismic reflection exploration technique which is one of the geophysical methods for oil exploration became effectively to image the subsurface structure with rapid development of computer. As a tool to perform seismic inversion, seismic forward modeling program using ray tracing should be developed. In this study, we have developed the algorithm that is to calculate the travel time of the complex geological structure using ray tracing by subdividing the geologic model into triangular element (finite element) having the constant velocity. We can analytically calculate Jacobian with some information by this current ray tracing. With this Jacobian, we will develop new algorithm which is to obtain geological properties and to image the subsurface. After subdividing subsurface into triangular element we shoot off the ray into subsurface by the Snell`s law. And then after taking the ray path which is similar to proper assumption we can calculate travel time. With ...
Geological clay formations are investigated for use as final underground deposit for heat producing nuclear waste. Special kinds of clay (e.g. bentonite) can also be used for the construction of geotechnical barriers. For the long time safety prognosis of the nuclear waste repositories the development of geochemical transport models is indispensable. The transport of aqueous solutions in clay is a complex process. The three-layer-minerals bentonite and illite swell by the adsorption of water, if the volume is restricted a high swelling pressure develops. The excellent barrier effect of natural clay formations and geotechnical clay barriers is based on the high swelling pressure and the high adsorption capacity for radionuclides and other pollutants. The two-layer-mineral kaolinite has no swelling capacity. In contrast to sandy layers a special geochemical transport potential exists in clay besides the well known matrix potential which influences essentially the transport process. ...
The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other x-ray examinations, especially computerised tomography. PMID:7134769
The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography.
The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography. (orig.).
In this work trailing edge noise levels of a research aerofoil have been computed and compared to aeroacoustic measurements using two different approaches. On the other hand, aerodynamic and aeroacoustic calculations were performed with the full Navier-Stokes CFD code Fluent [Fluent Inc 2005 Fluent 6.2 Users Guide, Lebanon, NH, USA] on the basis of a steady RANS simulation. Aerodynamic characteristics were computed by the aid of various turbulence models. By the combined usage of implemented broadband noise source models, it was tried to isolate and determine the trailing edge noise level. Throughout this work two methods of different computational cost have been tested and quantitative and qualitative results obtained. On the one hand, the semi-empirical noise prediction tool NAFNoise [Moriarty P 2005 NAFNoise User's Guide. Golden, Colorado, July. http://wind.nrel.gov/designcodes/ simulators/NAFNoise] ...
Purpose. To describe the characteristics of idiopathic macular holes (MH) on optical coherence tomography (OCT) and correlate OCT with clinical assessment. Design....Full Text Available
Selective alveolo-bronchography (SAB) has been routinely used to evaluate anatomical changes in the bronchiole and its distal air spaces. A narrowing of the bronchiole and abnormal pooling of contrast medium in the destroyed air space are the prime findings. Since the object of radiography is extremely thin, direct magnification radiography is mandatory to obtain radiologic details. However, the problem with this technique is that radiographic quality varies depending upon the size of the patient and the concentration of contrast medium to be introduced in the lung. This study had two goals. One was to improve the image quality of SAB by Fuji Computed Radiography (FCR). FCR provides radiographs with a good contrast and stable density throughout a wide range of exposure factors which occur in the use of SAB. The other goal was to separately evaluate morphological abnormalities in the outer and inner zones of the lung using X-ray CT. This idea was derived from our ...
Cardiac disease research relies increasingly on small animal models and non-invasive imaging methods such as positron emission tomography (PET) and magnetic resonance imaging (MRI). Delayed enhancement magnetic resonance imaging (DE-MRI) using gadolinium-based contrast agents appear to be a visualizing infracted myocardium with high spatial resolution. Polar map (or bull's-eye image) was used to determination of the myocardial infarction area. Polar map is a comprehensive interpretation of the left ventricle. The infarct size was computed as the fraction of the total polar map areas. The threshold was computed as the percentage of mean intensity of the normal region. In other study, 50% predefined threshold value in varying range (30?70%) was most commonly use. However, predefined threshold value isn't acceptance in all case. The purpose of this study was to investigate methodological approach for automatic measurement of ...
The role of high-resolution computedtomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. Postoperative HRCT depicted bony erosions ...
Malignant tumors of the sinonasal cavities are rare and often diagnosed late in the course of the disease. These tumors can extend into regions such as the orbit and brain, where treatment is difficult. Ten patients with non treated sinonasal malignant neoplasms and radiological evidence of tumor extension into the orbit and brain were studied with computedtomography. Five (50%) tumors were epithelial neoplasms whereas squamous cell carcinoma was the most common type (3 cases). The ethmoidal sinus was the most common site of origin of the tumors (40%), followed by the maxillary sinus (30%) and nasal cavity (30%). A total of 16 orbits were involved since 6 patients (60%) had bilateral orbital involvement. The tumors extended more often into the orbits through erosion of the medial and inferior orbital bones. All orbital compartments were involved in the majority of the orbits. Tumoral extension into the cranial cavity was more common through ...
Visualization of falx cerebral on non-enhanced computertomography (CT) of children with severe head injuries (the falx sign) has been regarded as an evidence of subarachnoid hemorrhage. On the contrary, other authors have reported reverse results. To evaluate clinical significance of the falx sign, authors studied frequency of visualization and CT number of falx cerebri and dural sinuses in 65 children with head injury and 65 children without head injury examined by cranial computertomography at the Department of radiology, St Paul's Hospital, Catholic Medical College from March to September, 1981. All patients with head trauma were studied within 1 week of the traumatic event. Visualization of falx cerebri was observed at slice in the region of lateral ventricle and slice near to vertex respectively. On the slice in the region of lateral ventricle, falx cerebri was identified in 82% of all ...
The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computedtomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system resolution have hot been determined. The TNIF is currently being ...
Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to ComputedTomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas ComputedTomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only a small fraction of the neutrons incident on the object are scattered to the neutron camera, a new neutron beamport facility, with a larger ...
It has been five years since the last in-depth American College of Nuclear Physicians/Society of Nuclear Medicine Symposium on the subject of single photon emission computedtomography (SPECT) was held. Because this subject was nominated as the single most desired topic we have selected SPECT imaging as the basis for this year's program. The objectives of this symposium are to survey the progress of SPECT clinical applications that have taken place over the last five years and to provide practical and timely guidelines to users of SPECT so that this exciting imaging modality can be fully integrated into the evaluation of pathologic processes. The first half was devoted to a consideration of technical factors important in SPECT acquisition and the second half was devoted to those organ systems about which sufficient clinical SPECT imaging data are available. With respect to the technical aspect of the program we have selected the key areas which ...
Fuel rod failures produce a release of fission products into primary coolant system. Since nuclear power plants have licensing limits for the release of volatile fission products to the environment (off-gas limits) detailed monitoring of the development of clad failure is necessary. In case of fuel rod failure a release of fission products into the primary coolant system arises. Fission gases accumulated in the free volume of a fuel rod escape through the clad defect. Water entering the fuel rod reacts with fission products, forming volatile chemical compounds. These may escape in a similar manner into the fission gases. Other compounds may dissolve and may be carried outside the fuel rod as dissolved species. Consequently, the distribution of these fission products, in the cross section of the fuel rod, is modified. An implementation of the maximum entropy gamma computedtomography technique is used to obtain such distributions in the area of ...
Objective: To compare the enhancement pattern of hilar cholangiocarcinoma on contrast-enhanced ultrasound (CEUS) with that on contrast-enhanced computedtomography (CECT). Methods: Thirty-two consecutive patients with pathologically proven hilar cholangiocarcinomas were evaluated by both low mechanical index CEUS and CECT. The enhancement feature of the tumor, portal vein infiltration, and lesion conspicuity on them was investigated. Results: In the arterial phase, the numbers of the lesions showing hyperenhancement, isoenhancement, and hypoenhancement, were 14 (43.8%), 14 (43.8%), and 4 (12.6%), on CEUS, and 12 (37.5%), 9 (28.1%), and 11 (34.4%), on CECT (P = 0.162). In portal phase, the numbers of the lesions showing hypoenhancement, isoenhancement, and hyperenhancement were 30 (93.8%), 1 (3.1%), and 1 (3.1%), on CEUS, and 23 (71.9%), 8 (25.0%), and 1 (3.1%), on CECT (P = 0.046). The detection rates for portal vein infiltration were 84.2% ...
Purpose/Objective. Daily Cone-beam computedtomography (CBCT) in room imaging is used to determine tumour shrinkage during a full radiotherapy (RT) course. In addition, relative interfractional tumour and lymph node motion is determined for each RT fraction. Material and methods. From November 2009 to March 2010, 20 consecutive lung cancer patients (14 NSCLC, 6 SCLC) were followed with daily CBCT during RT. The gross tumour volume for lung tumour (GTV-t) was visible in all daily CBCT scans and was delineated at the beginning, at the tenth and the 20th fraction, and at the end of treatment. Whenever visible, the gross tumour volume for lymph nodes (GTV-n) was also delineated. The GTV-t and GTV-n volumes were determined. All patients were setup according to an online bony anatomy match. Retrospectively, matching based on the internal target volume (ITV), the GTV-t or the GTV-n was performed. Results. In eight patients, we observed a significant ...
Accurate diagnosis of local invasion of hilar cholangiocarcinomas is challenging due to their small size and the anatomic complexity of the hepatic hilar region. On the other hand, the correct diagnosis of local invasion is essential for assuring the possibility of curative surgery. The purpose of this study was to evaluate the feasibility of four-channel multidetector-row computedtomography (MDCT) in the assessment of vascular and bile duct involvement, by which we could obtain useful information for the surgical management of hilar cholangiocarcinoma. The subjects were 18 patients for whom the extent of tumor invasion was surgically and pathologically confirmed. All patients underwent preoperative multiphasic CT scanning by MDCT. Arterial and portal dominant phases were acquired using a detector configuration of 1.25 mm x 4 mm, and both axial and multiplanar reconstructed images were interpreted. Longitudinal extension was evaluated up to ...
The cavum septum pellucidum is an anatomical variants of the septum pellucidum, and lying between two lateral ventricles and this is referred to as the fifth ventricle. Occasionally, posterior extension of the cavum septum pellucidum towards the splenium is seen and this is known as the cavum vergae, or sixth ventricle. The septum is double membrane and occasionally a narrow cavity containing CSF is present between these membrane. The roof of the cavum septum pellucidum is formed by the corpus callosum and its floor by the anterior pillars of the fornix. This cavum outlined with air is occasionally seen in the pneumoencephalography. Brain CT scans of 1000 patients were performed, and the diagnosis could be made on the basis of the characteristic shape, density and location. Other diagnostic procedure are not necessary in these cases. Patients were examined with CT scanner from June-80' to Dec-80', at department of radiology, Maryknoll Hospital, and 13 cases were ...
Pulmonary infections and tumors are a major cause of death in patients with AIDS. The combination of clinical, radiological, laboratory, and pathohistological data helps to narrow the spectrum of differential diagnoses or even allows a specific diagnosis in many patients. Nevertheless, an accurate diagnosis should be obtained as soon as possible during the clinical course of the illness to initiate treatment in time. Computedtomography (CT) has proven to provide promising results in the diagnosis of AIDS-related throacic diseases. The aim of this paper was to demonstrate the diagnostic capacities of CT in the context of particular AIDS-related thoracic pathologies. Additional information on the spectrum of pathological agents and on differential diagnostic signs is summarized. (orig.) [Deutsch] Pulmonale Infektionen und Tumore sind eine wesentliche Todesursache bei Patienten, die am erworbenen Immunmangelsyndrom AIDS leiden. In den meisten ...
The authors carried out a retrospective study on 4 years' work on a series of patients with proved active tuberculosis examined in the Departments of Bronchopneumology and Infectious Disease of the Arezzo Civil Hospital. The population was heterogenerous from the immunologic viewpoint. This paper compared the effectiveness of ComputedTomography (CT) with that of conventional chest radiography (CR) in the diagnosis and prognosis of tuberculosis. All patients underwent chest CR in double projection and conventional CT studies of the chest; 16 patients were also submitted to high resolution CT (HRCT). Consolidation was the most frequent parenchymal lesion in immunocompetent patients; it was often associated with cavitation, with no clear topographic prevalence in the upper lobes. Pleural effusion, as the only sign of disease and with empyema features, was found in 10 immunocompetent patients. No predominant pattern was found in the other two ...
The aim of this study was to compare multidetector-row computedtomography (MDCT) findings between cases of sclerosing cholangitis with autoimmune pancreatitis (SC-AIP) and infiltrative extrahepatic cholangiocarcinoma (IEC). We retrospectively assessed MDCT findings from 16 IEC cases and 13 SC-AIP cases. MDCT findings were analyzed with regard to location, length, wall thickness, contour, stricture wall enhancement pattern, proximal duct diameter, and the presence of diffuse concentric thickening in the proximal duct and gallbladder wall thickness. Stricture length, stricture wall thickness, and proximal duct diameter were significantly smaller for SC-AIP than for IEC: 19.3#+-#8.7 vs. 31.8#+-#12.0 mm (P=0.004), 2.1#+-#1.3 vs. 4.1#+-#1.3 mm (P<0.001), and 9.2#+-#3.9 vs. 13.3#+-#5.0 mm (P=0.012), respectively. SC-AIP was correlated with stricture location in both the intrapancreatic and hilar hepatic bile ducts, concentric stricture contour ...
Objective was to assess the accuracy of a single versus combined use of ultrasound (US) or computedtomography (CT) in the localization of diseased parathyroid glands. Forty-one patients with hyper-parathyroidism treated surgically between January 2000 to December 2005 at Jordan University Hospital, Amman, Jordan were included in this study. Preoperative ultrasonographic and CT findings were reviewed and compared to the intraoperative and pathologic diagnosis of diseased parathyroid glands. The mean age of patients was 46 years (range 16-70; 15 males and 26 females). Parathyroid adenoma was confirmed in 33 patients and hyperplasia of the parathyroid glands in 8 patients. Preoperative evaluation was carried out in 32 patients (CT scan) and in 23 patients (US). In 18 cases, the diagnosis of parathyroid disease was based on CT findings alone and in 9 patients the diagnosis was based on a single US finding. Combined CT and US evaluation was carried ...
Positron emission tomography (PET) is a fully quantitative technology for imaging metabolic pathways and dynamic processes in vivo. Attenuation correction of raw PET data is a prerequisite for quantification and is typically based on separate transmission measurements. In PET/CT attenuation correction, however, is performed routinely based on the available CT transmission data. Recently, combined PET/magnetic resonance (MR) has been proposed as a viable alternative to PET/CT. Current concepts of PET/MRI do not include CT-like transmission sources and, therefore, alternative methods of PET attenuation correction must be found. This article reviews existing approaches to MR-based attenuation correction (MR-AC). Most groups have proposed MR-AC algorithms for brain PET studies and more recently also for torso PET/MR imaging. Most MR-AC strategies require the use of complementary MR and transmission images, or morphology templates generated from ...
Diseases of the mandible affect the soft tissues aside from the osseous manifestation. This can be shown clearly and in great detail by magnetic resonance imaging (MRI). MRI is the gold standard in the diagnostic evaluation of any internal derangement of the temporomandibular joint. Dental MRI requires high resolution techniques and in some cases also intravenous administration of contrast material. These techniques allow delineation of the neurovascular bundle. In the past few years new indications were formulated, for example, the evaluation of the integrity of the inferior alveolar nerve in trauma and in radicular cysts. New quantitative methods now enable insights into the pathophysiology. The objective of this review is to communicate accepted indications for MRI of the mandible and to present innovative applications. (orig.) [German] Mandibulaere Erkrankungen beteiligen neben dem Knochen Weichteilstrukturen, die sich mit der MRT klar und detailreich ...
A graphic approach, terms a Genetic Activity Profile (GAP), was developed to display a matrix of data on the genetic and related effects of selected chemical agents. The profiles provide a visual overview of the quantitative (doses) and qualitative (test results) data for each chemical. Either the lowest effective dose or highest ineffective dose is recorded for each agent and bioassay. Up to 200 different test systems are represented across the GAP. Bioassay systems are organized according to the phylogeny of the test organisms and the end points of genetic activity. The methodology for producing and evaluating genetic activity profile was developed in collaboration with the International Agency for Research on Cancer (IARC). Data on individual chemicals were compiles by IARC and by the US Environmental Protection Agency (EPA). Data are available on 343 compounds selected from volumes 1-53 of the IARC Monographs and on 115 compounds identified as Superfund ...
Geological, geophysical, thermal, petrophysical and hydrological data available for the East Mesa hydrothermal system that are pertinent to the construction of a computer model of the natural flow of heat and fluid mass within the system are assembled and correlated. A conceptual model of the full system is developed and a subregion selected for quantitative modeling. By invoking the Boussinesq approximation, valid for describing the natural flow of heat and mass in a liquid hydrothermal system, it is found practical to carry computer simulations far enough in time to ensure that steady-state conditions are obtained. Initial calculations for an axisymmetric model approximating the system demonstrate that the vertical formation permeability of the deep East Mesa system must be very low (k/sub v/ approx. 0.25 to 0.5 md). Since subsurface temperature and surface heat flow data exhibit major deviations from the axisymmetric ...
A technique for quantitative determination of cephalothin and desacetylcephalothin in serum using a method based on high-pressure liquid chromatography is described. Both compounds were quantitatively...Full Text Available
A novel phantom has been developed to measure the modulation transfer function (MTF) in 3D for x-ray computedtomography. The phantom consists of three tungsten wires, positioned nearly orthogonal to each other. Simultaneous measurements of the MTF are taken at various locations along the three orthogonal reconstructed planes. Our computed mammotomography (CmT) system uses a Varian Paxscan 2520 digital x-ray detector which can be positioned anywhere in ~2pi steradian band and can have arbitrary trajectories. With a half-cone beam geometry and with the phantom positioned near the center of rotation, projection images are acquired over 360 degrees. Various 3D orbits are evaluated including vertical axis of rotation and saddle. Reconstructions were performed using an iterative ordered-subsets transmission algorithm on rebinned projection images, using various numbers of iterations. Rotation of reconstructed slices isolated ...
The use of the ratio of the characteristic intensity to the continuum background intensity (P/B ratio) of the X-ray spectrum for a quantitative ion microprobe (IMP) or PIXE (particle induced X-ray emission) analysis of thin biological specimens was proposed previously. The IMP analysis of thick biological specimens is also of considerable practical use. In this paper, the possibility of using the P/B ratio to quantify minor elements in thick biological specimens is investigated. The epoxy resin based standards with gradual concentrations of KCNS up to 0.6 mol/kg and NBS bovine liver were analyzed by a 27 MeV {alpha} particle microprobe. The measured peak to background ratios (between 4.4 to 5.7 keV) agreed well with the theoretical calculations. The calculations showed that the concentration dependence of the P/B ratios was determined mainly by the absorption of X-rays in specimens. The results indicate that the P/B method is useful for IMP analysis of thick ...
Quantitative assessment of bone scintigraphy was performed in fifty-six patients with hip joint disease including femoral neck fracture, aseptic necrosis of the femoral head, traumatic dislocation of the hip, Perthes disease, and transient synovitis of the hip. In the static study, bone scintigraphy was obtained 3 hours after injection of sup(99m)Tc-MDP by gamma camera equipped with a computer and uptake ratios were calculated. In the dynamic study, bone scintigraphy was performed in one, 3 and 5 hours after injection of radionuclide. Femoral head uptake ratio was markedly decreased in osteonecrosis following femoral neck fracture and characteristically increased in aseptic necrosis of the femoral head but prolonged retention of sup(99m)Tc-MDP could be observed. Uptake ratios of epiphysis were decreased in Perthes disease but normal in transient synovitis of the hip. Static and dynamic study of bone scintigraphy may be useful for early ...
Quantitative bone scintigraphy was performed on 23 white females with post-menopausal osteoporosis and vertebral compression fractures. These patients were then entered into a randomized, double-blind clinical trial or sodium fluoride therapy (NaF=14, placebo=9) which included repeat bone scintigraphy every six months. Scintigraphic images were acquired for 500K counts per image over the total body with computer acquisition over the posterior thoracic and lumbar spine. Images were obtained on a wide field-of-view gamma camera two hours after injecting 15 mCi of Tc-99m MDP. Data analysis showed a significant reduction in the activity ratio of abnormal vertebral body to normal vertebral body in those patients treated with sodium fluoride (paired t-test p=0.0095). No significant change was observed in the control group of (p=0.142). These results suggest that sodium fluoride therapy promotes more rapid healing of osteoporotic vertebral fractures. ...
Reflection tomography allows in theory the determination of the velocity distribution and the reflector geometries in the subsurface from the travel times of the seismic waves. The solution of the inverse problem is the model (velocity distribution and reflectors) that minimizes the misfits between observed travel times and travel times computed by raytracing (the forward problem). Two representations of the velocity field are generally used: blocky models (discontinuous) and smooth models. The object of this thesis is the study of tomography with smooth models which offer interesting properties at a practical level as well as at a mathematical and numerical level. We propose an original formulation of the inverse problem which allow the integration of a priori information adapted to smooth models. This formulation assures the existence, the uniqueness and the stability of the solution of the linearized inverse problem. The ...
There are clearly identified scientific requirements for continuous profiling of atmospheric water vapor at the Department of Energy, Atmospheric Radiation Measurement program, Southern Great Plains CART (Cloud and Radiation Testbed) site in northern Oklahoma. Research conducted at several laboratories has demonstrated the suitability of Raman lidar for providing measurements that are an excellent match to those requirements. We have developed and installed a ruggedized Raman lidar system that resides permanently at the CART site, and that is computer automated to eliminate the requirements for operator interaction. In addition to the design goal of profiling water vapor through most of the troposphere during nighttime and through the boundary layer during daytime, the lidar provides quantitative characterizations of aerosols and clouds, including depolarization measurements for particle phase studies.
A computer method that calculates tracheal cross-sectional area by compensating for partial volume averaging was developed and validated in a study with phantoms. The program was then used to determine the tracheal cross-sectional area of 30 normal children who ranged in age from four months to 18 years. CT-derived cross sections were correlated with age, height, weight, and body-surface area, and they were compared with findings of published clinical and post-mortem studies. CT cross-sectional areas ranged from 20 to 275 mm/sup 2/, varied by as much as 22% at the three different tracheal levels studied, and appeared to correlate most closely with body height. CT-derived tracheal cross-sectional areas are quite similar to those in published reports of postmortem and clinical studies. Measurements of tracheal cross section by CT may prove useful in quantitating tracheal compromise by intrinsic or extrinsic causes.
A new methodology for three-dimensional (3-D) numerical modeling of the continuous steel casting process is presented and evaluated. The results are compared with available experimental data obtained in a water-oil mold model for various flow rates and immersion depths of the submerged entry nozzle. The water-oil interface pattern at the top of the mold is also investigated. Wave formation and evolution in time is simulated with a volume tracking method. The predicted flow field inside the mold exhibits quite satisfactory agreement with the corresponding measurements, whereas some quantitative differences are observed referring to the final wave amplitude at low casting speeds. Conclusions of scientific and engineering importance concerning both the computer algorithm and the mold performance are also drawn.
The auroras on Jupiter and Saturn can be studied with a high sensitivity and resolution by the Hubble Space Telescope (HST) ultraviolet (UV) and far-ultraviolet (FUV) Space Telescope spectrograph (STIS) and Advanced Camera for Surveys (ACS) instruments. We present results of automatic detection and segmentation of Jupiter's auroral emissions as observed by HST ACS instrument with VOronoi Image SEgmentation (VOISE). VOISE is a dynamic algorithm for partitioning the underlying pixel grid of an image into regions according to a prescribed homogeneity criterion. The algorithm consists of an iterative procedure that dynamically constructs a tessellation of the image plane based on a Voronoi Diagram, until the intensity of the underlying image within each region is classified as homogeneous. The computed tessellations allow the extraction of quantitative information about the auroral features such as mean intensity, latitudinal and longitudinal ...
To make a quantitative comparison of risks between the SNR-300 and a modern PWR (Biblis B), the consequences of an accident or the extent of damage of a release of radionuclides to the environment due to an accident are estimated by computer programs for accident consequence models. The accident analysis includes an analysis of events for Bethe-Tait accidents with failure of the outer containment. The FGSB release rates are compared with those of the Society for Reactor Safety (GRS).
This paper is concerned with the real time automatic discriminating of flaws from two categories; i. cracks (planar defect) and ii. Non-cracks (volumetric defect such as cluster porosity and slag) using pulse-echo ultrasound. The raw ultrasonic flaws signal were collected from a computerized robotic plane scanning system over the whole of each reflector as the primary source of data. The signal is then filtered and the analysis in both time and frequency domain were executed to obtain the selected feature. The real time feature analysis techniques measured the number of peaks, maximum index, pulse duration, rise time and fall time. The obtained features could be used to distinguish between quantitatively classified flaws by using various tools in artificial intelligence such as neural networks. The proposed algorithm and complete system were implemented in a computer software developed using Microsoft Visual BASIC 6.0 (author)
We present a numerical model of vapor-dominated reservoirs which is based on the well-known conceptual model of White, Muffler, and Truesdell. Computer simulations show that upon heat recharge at the base, a single phase liquid-dominated geothermal reservoir in fractured rock with low matrix permeability will evolve into a two-phase reservoir with B.P.D. (boiling point-for-depth) pressure and temperature profiles. A rather limited discharge event through cracks in the caprock, involving loss of only a few percent of fluids in place, is sufficient to set the system off to evolve a vapor-dominated state. The attributes of this state are discussed, and some features requiring further clarification are identified. 26 refs., 5 figs.
This study is an attempt to measure the quantities of elements in a composite by irradiating that composite with #gamma#-rays of various energies and detecting the transmitted radiation through the composite. A previous knowledge of the number of the elements and their attenuation coefficients is required. The quantities are calculated by solving the matrix of a linear system of equations. A computer program was developed to select the best combinations of the available energies. Five criteria were established to determine these energy combinations: (i) the determinant of the attenuation coefficient matrix; (ii) the condition number, (iii) the number of times the solution of the matrix leads to acceptable results; (iv) the indicator, (a new concept); (v) the standard deviations of the results. The intended application of this technique in medicine is to measure the bone mineral content of the skeleton. An examination of the error propagation, the application of ...
The radionuclide X-ray fluorescence analyzer consists of a source changer and a sample changer. "5"5Fe, "1"0"9Cd and "2"4"1Am are used as excitation sources. The radiation is detected with a semiconductor Si(Li) detector. The complete assembly of the apparatus consists of an imagine unit, a keyboard, a floppy disc drive, a printer, a console and a rack with analog and digital electronics. Its multichannel amplitude analyzer consists of power supplies, a high voltage supply, a linear amplifier, an analog-to-digital converter and a computer. The technical specifications are given. The control and data processing system is controlled with an MHB 8080A microprocessor. Software for semiconductor gamma spectrometry and for quantitative gamma spectrometry will be supplied with the equipment. (E.S.). 3 figs., 4 refs.
Since high resolution sequence stratigraphy was introduced into China by DENG Hong-wen in 1995, it has been experienced two development stages in China which are the beginning stage of theory research and development of theory research and application, and the stage of theoretical maturity and widely application that is going into. It is proved by practices that high resolution sequence stratigraphy plays more and more important roles in the exploration and development of oil and gas in Chinese continental oil-bearing basin and the research field spreads to the exploration of coal mine, uranium mine and other strata deposits. However, the theory of high resolution sequence stratigraphy still has some shortages, it should be improved in many aspects. The authors point out that high resolution sequence stratigraphy should be characterized quantitatively and modelized by computer techniques. (authors)
The knowledge of wound ballistics and of wounding mechanisms is mandatory for the radiologist to interpret the CT findings of gunshot wounds. The severity of a bullet wound depends on the characteristics of the tissue it goes through, i.e., tissue elasticity, density, thickness of the wounded body part, the type of tissue, its specific gravity, internal cohesiveness and anatomical relationships, as well as on missile characteristics, i.e., mass, shape, fragmentation and deformation. Bullet velocity is certainly a major factor in wounding, but it is only one factor. Two major wounding mechanisms exist the crushing of the bullet-struck tissue (forming the permanent cavity) and radial stretching (forming a temporary cavity). Bullet "yaw" is defined as the angle between the long axis of the bullet and its flight path. The yaw is directly proportional to tissue crushing and stretching: the wider the yaw, the most severe tissue crushing and stretching and, therefore, the more severe tissue ...
An interfacial shear stress equation in the dispersed-annular two-phase flow regime has been developed, which is based on a three-fluid model consisting of a liquid film on a rod, vapor and entrained liquid associated with a vapor flow. It is an extension of J.G.M. Andersen's procedure that provides a two-fluid interfacial shear stress equation using the drift flux parameters C{sub 0} and V{sub gj}. This interfacial shear stress equation can take into account a phase and velocity distribution through an equivalence between the drift flux parameters and the interfacial shear stress. Using the three-fluid subchannel analysis code TEMPO with the three-fluid interfacial shear stress model the capability of a three-fluid calculation using the drift flux parameters C{sub 0} and V{sub gj} that reproduce a measured void fraction is demonstrated. A comparison was made with advanced X-ray computedtomography (CT) void fraction data within a 4x4 ...
Purpose: To evaluate micro computedtomography (micro-CT) for the assessment of osteochondritis dissecans in comparison with histology. Material and Methods: Osteochondritis dissecans lesions of 3 patients were evaluated using micro-CT (0.125 mA, 40 keV, 60 m slice thickness, 60 m isotropic resolution, entire sample) and light microscopy (toluidine blue, 3-5 m slice thickness). The methods were compared regarding preparation time, detectability of tissue types and morphologic features of bone and cartilage. Results: Non-destructive micro-CT imaging of the entire sample was faster than histologic preparation of a single slice for light microscopy. Morphologic features of bone and cartilage could be imaged in a comparable way to histology. It was not possible to image cells or different tissue types of bone and cartilage with micro-CT. Conclusion: Micro-CT is a fast, non-destructive tool that may be a supplement or, if detailed histologic ...
Purpose: To evaluate micro computedtomography (micro-CT) for the assessment of osteochondritis dissecans in comparison with histology. Material and Methods: Osteochondritis dissecans lesions of 3 patients were evaluated using micro-CT (0.125 mA, 40 keV, 60 m slice thickness, 60 m isotropic resolution, entire sample) and light microscopy (toluidine blue, 3-5 m slice thickness). The methods were compared regarding preparation time, detectability of tissue types and morphologic features of bone and cartilage. Results: Non-destructive micro-CT imaging of the entire sample was faster than histologic preparation of a single slice for light microscopy. Morphologic features of bone and cartilage could be imaged in a comparable way to histology. It was not possible to image cells or different tissue types of bone and cartilage with micro-CT. Conclusion: Micro-CT is a fast, non-destructive tool that may be a supplement or, if detailed histologic ...
The lymphographic agent Lipiodol (iodized oil) has been found to localize and remain in tumor vessels. Based on this finding, we attempted transcatheter internal radiotherapy by radioactive iodized oil (I-131 tagged Lipiodol) prepared by isotopic exchange reaction. Transcatheter internal radiotherapy (TCIR) was attempted in twelve patients with inoperable hepatoma by infusing a therapeutic dose of I-131 Lipiodol (7.6 approx. 28.3 mCi/2.0 approx. 5.0 ml) via the hepatic artery. Serial changes of serum alpha-fetoprotein (AFP) levels and in the size of tumor on computedtomography (CT) were estimated to evaluate the therapeutic effect. Serum AFP levels decreased in 9 patients with initial elevated levels of serum AFP, although they were again elevated in three of them within four weeks. More than 50 % decrease in tumor size was observed in 6 patients (50 %). There were no serious complications. This preliminary results suggest that TCIR with I-131 ...
Purpose: To assess the prevalence, significance and practical value of two recently described CT signs of instable aneurysm: the crescent sign and the periluminal halo (a low-attenuating internal layer of the thrombus around the patent lumen). Material and methods: Among the CT examination performed in the last 5 years, they retrospectively selected the nonruptured aneurysms with a diameter exceeding 4 cm (no. = 93 average diameter 5.1 cm, unenhanced images in 28 cases and enhanced in 84) and the ruptured aneurysms (no. = 16, average diameter 6.7 cm, unenhanced images in 9 cases and enhanced in 9). They studied the prevalence of the crescent and halo sing, their relationship with the aneurysm diameter, and the effect of contrast enhancement. Results: The crescent sign was identified with a statistically significant prevalence in ruptured ( 37.5 % or cases) over asymptomatic aneurysms (5.5 %); the halo had the same frequency in the 2 groups (12.5 % and 9.5 %). Both signs were more ...
Both x-ray and optical cone-beam CT (CBCT) scanners are limited by scattered photons that contaminate the primary images. Transparent radiochromic gels and plastics are anticipated to produce less scattering than polymerization gels and hence result in reconstructed dose distributions with greater contrast and dynamic range. Four methods of scatter measurement were investigated to quantify scatter fractions using an in-house optical CBCT scanner. The methods consisted of generating either 'coin' shadows or primary beamlets in transmission images. The four methods generated similar results of 10% scatter fractions in gel transmission images for this particular scanner configuration with both leuco crystal violet and carbon black micelle gels. The scatter contributions were distributed as 5% from micelle gel, 2% from Teflon wall, 2% from refractive index matching liquid and 1% other sources. Applying a uniform background subtraction of 2% of open field intensity ...
The relationship between the QRS transition zone of the standard 12-lead ECG and interventricular septum was studied. The position and the angle to the horizontal line of the interventricular septum were evaluated with computedtomography (CT) and compared to the QRS transition zone. The subjects were 36 patients with no cardiovascular diseases. The patients were divided into 3 groups according to the position of QRS transition zone: V{sub 1}-V{sub 2} (8 cases), V{sub 3}-V{sub 4} (21 cases), and V{sub 5}-V{sub 6} (7 cases). The interventricular septum on CT was directed to the anterior chest wall between V{sub 3} and V{sub 4} in all 3 groups. The mean value of the interventricular septal angle did not differ from group to group, 52.1deg for V{sub 1}-V{sub 2} group, 49.8deg for V{sub 3}-V{sub 4} group, and 48.2deg for V{sub 5}-V{sub 6}. It was concluded that the direction of the interventricular septum was not one of the major determinants of ...
{sup 99m}Tc-N-pyridoxyl-5-methyl-tryptophan (PMT) scintigraphy, which exhibits highly specific for the diagnosis of primary hepatocellular carcinoma (HCC), was performed for recurrent HCC following non-surgical treatment. Eighty-four patients (total 351 examinations) were selected for the study. The ability of PMT scintigraphy to diagnose recurrent HCC after treatment was compared with that of computedtomography, ultrasonography and angiography. The results showed that sixty-three (75%) of 84 cases demonstrated positive findings during our follow-up period, most of the tumors initially showing positive findings remained PMT positive when they recurred and PMT studies shortly after treatment demonstrated wider tracer uptake rather than the actual tumor area. In conclusion, PMT scintigraphy for patients with HCC after non-surgical treatment exhibited high accuracy in identifying viable HCC only for tumors indicating positive findings. (author)
In developing new brain imaging agents for single photon emission computedtomography (SPECT), we synthesized eleven radioiodinated phenoxyacetic acid derivatives and investigated the relationship between the chemical structure and in vivo characteristics. Biodistribution studies in mice revealed high initial brain uptake for all the compounds. Blood radioactivity level depended markedly upon the chemical stability of the compound. The #alpha#,#alpha#-dimethylester derivative (1e), amide derivatives (2a-c) and diamine derivatives (3a, b, 4), which were stable to hydrolysis, showed low blood activity levels following i.v. administration. Disappearance of the ester and amide compounds from the brain was rapid. However, the diamine derivatives displayed improved retention in the brain. Compounds 3a and 4 possessed the best combination of high brain uptake and sufficient retention to be useful as potential brain imaging radiopharmaceuticals with ...
The mortality in undrained abdominal abscesses is high with a mortality rate ranging between 45 and 100%. The outcome in abdominal abscesses, however, has improved due to advances in image guided percutaneous interventional techniques. The main indications for the catheter drainage include treatment or palliation of sepsis associated with an infected fluid collection, and alleviation of the symptoms that may be caused by fluid collections by virtue of their size, like pancreatic pseudocele or lymphocele. The single liver abscesses may be drained with ultrasound guidance only, whereas the multiple abscesses usually require computedtomography (CT) guidance and placement of multiple catheters. The pancreatic abscesses are generally drained routinely and urgently. Non-infected pancreatic pseudocysts may be simply observed unless they are symptomatic or cause problems such as pain or obstruction of the biliary or the gastrointestinal tract. ...
We investigated a method of analyzing the hemodynamics of the lung mass by contrast enhanced dynamic computedtomography (dynamic CT) to determine the difference in vascular supply between the pulmonary artery and bronchial artery using an experimental model. Our experimental model consisted of two injectors connected to two tubes, representing the pulmonary artery and bronchial artery, which were further connected to a chamber representing the lung mass. Following infusion of contrast medium into each tube with some delay time, dynamic CT scans were performed to obtain time density curves of the two tubes and the chamber. Using the time-density curve of contrast passage, flow rates from the two tubes into the chamber were calculated by the curve fitting method. Calculated values correlated well with the adopted flow rates of fluid from the injectors (r=0.893) in the experiment. The results indicate our method of individually measuring flow ...
We investigated a method of analyzing the hemodynamics of the lung mass by contrast enhanced dynamic computedtomography (dynamic CT) to determine the difference in vascular supply between the pulmonary artery and bronchial artery using an experimental model. Our experimental model consisted of two injectors connected to two tubes, representing the pulmonary artery and bronchial artery, which were further connected to a chamber representing the lung mass. Following infusion of contrast medium into each tube with some delay time, dynamic CT scans were performed to obtain time density curves of the two tubes and the chamber. Using the time-density curve of contrast passage, flow rates from the two tubes into the chamber were calculated by the curve fitting method. Calculated values correlated well with the adopted flow rates of fluid from the injectors (r=0.893) in the experiment. The results indicate our method of individually measuring flow ...
Sonography, subtraction scintigraphy, computedtomography and MRI were compared in 100 patients who had surgery 105 times for hyperparathyroidism (HPT). Surgical and pathological data were available for all operations. A total of 105 MR, 77 CT, 84 sonograms and 70 subtraction scintigrams were performed. The ability of the imaging modalities, individually and in combination, to detect HPT, histology, size, concomitant thyroid disease and location of the diseased glands has been evaluated. For primary HPT, sensitivity ranged from 68% for MRI to 40% for scintigraphy but was much lower for tertiary HPT with all modalities. The ability to identify diseased glands was strongly size dependent for all methods. If patients had had previous neck surgery, the most sensitive methods were MRI and scintigraphy and this also held true for patients with concomitant thyroid disease and ectopically located glands. The findings presented suggest that while ...
Magnetic resonance (MR) images of 18 cases of hilar cholangiocarcinoma were evaluated to compare the effectiveness of Gd-DTPA with that of high dose contrast enhancement computedtomography (HCE-CT) in detecting the primary tumor. The primary tumor was demonstrated as having slightly low intensity compared with liver parenchyma and high intensity compared with the delated bile duct on T1-weighted images. In contrast, MRI using Gd-DTPA, which was carried out in five cases, revealed intense enhancement of the tumor. As the differentiation between cholangiocarcinoma and dilated bile duct was difficult, it was concluded that the use of Gd-DTPA improves the efficacy of MRI in diagnosing cholangiocarcinoma. Gd-DTPA was also effective in differentiating the growth pattern of the tumor: the infiltrating type was demonstrated as thickening of the wall of the bile duct, the polypoid type as a soft tissue mass in the bile duct. Contrast MRI study is ...
Ectopically located parathyroid adenomas may be difficult to find during initial neck exploration. They account for over 70 percent of missed adenomas found at reexploration. Preoperative localization of parathyroid adenomas would reduce unnecessary dissection and possibly reduce the number of negative results of initial neck exploration. Before reoperative parathyroid surgery is performed, some means of localization is mandatory to detect ectopic adenomas in the neck and mediastinum. Computedtomography and ultrasonography cannot effectively evaluate the mediastinum. Angiography and venous parathyroid hormone sampling are invasive, costly, and tedious to perform. We have shown that thallium-201 will accurately localize ectopic parathyroid adenomas. All 10 adenomas found in positions not immediately adjacent to the thyroid gland were detected by thallium-201 scintigraphy. One was a mediastinal adenoma resected with a median sternotomy. Our ...
Many otolaryngologists perform septoplasty with or without turbinate surgery and the surgical method relies largely on the surgeon's clinical judgment. This study used computedtomography (CT) of the sinuses of 20 patients to examine the correlation between a unilateral deviated nasal septum and compensatory hypertrophy of the contralateral inferior turbinate to suggest guidelines for septal and turbinate surgery. The thickness of the mucosa and conchal bone, the projection angle of the conchal bone, and the distances between the conchal bone, and lateral nasal line and median line were measured. The volume of the inferior turbinate was measured from the three-dimensional reconstruction. Each measurement was compared with those of the nasal cavity on the contralateral and of normal control subjects. The inferior turbinate on the concave side had a significantly greater volume, including the thickness of medial mucosa and the thickness and ...
Iodixanol is a new nonionic dimer, isotonic with blood at all clinically relevant concentrations. Iodixanol (270 mg I/ml) was compared in a double-blind, randomized, parallel-group, phase-III study to the monomeric nonionic iohexol (300 mg I/ml) for evaluation of safety, tolerability and radiographic efficacy during cerebral CT. One hundred adult patients scheduled to undergo contrast-enhanced cerebral CT were randomly allocated to receive either iodixanol or iohexol. All completed the trial. Safety was evaluated by recording discomfort and other adverse events, tolerance by assessing intensity and incidence of discomfort. Radiographic efficacy was assessed from the diagnostic information and the radiographic density. No serious adverse events occurred. One patient (2 %) in the iodixanol group and one patient (2 %) in the iohexol group experienced a transient reddening at the neck and lower neck-line, respectively. Both contrast agents were well tolerated. One patient (2 %) in the ...
Megavoltage photon intensity-modulated radiation therapy (IMRT) is typically used in the treatment of prostate cancer at our institution. Approximately 1% to 2% of patients with prostate cancer have hip prostheses. The presence of the prosthesis usually complicates the planning process because of dose perturbation around the prosthesis, radiation attenuation through the prosthesis, and the introduction of computedtomography artifacts in the planning volume. In addition, hip prostheses are typically made of materials of high atomic number, which add uncertainty to the dosimetry of the prostate and critical organs in the planning volume. When the prosthesis is bilateral, treatment planning is further complicated because only a limited number of beam angles can be used to avoid the prostheses. In this case study, we will report the observed advantages of using noncoplanar beams in the delivery of IMRT to a prostate cancer patient with bilateral ...
Ewing's sarcoma is a highly malignant neoplasm of the bone whose origin is still uncertain. A strong relationship exists between Ewing's sarcoma and tumors of neural origin (Ewing family of tumors). Ewing's sarcoma must be distinguished from other round-cell tumors like lymphoma and neuroblastoma and also must be differentiated from osteogenic sarcomas. On plain radiographs, Ewing's sarcoma appears as a lytic or mixed lytic-sclerotic, rarely as predominantly sclerotic lesion with margins Lodwick grade III. It is located primarily in the diaphyseal and metadiaphyseal regions of the long bones of the lower extremities. A large soft tissue tumor is usually present. Magnetic resonance imaging is the imaging modality of choice to evaluate the extent of the primary lesion, to monitor the response to neoadjuvant chemotherapy and to follow up non-resected Ewing's sarcomas. Bone scintigraphy is necessary to detect skeletal metastasis, and "2"0"1thallium scanning has been shown to be sensitive ...
Premature fusion of multiple cranial sutures has been associated with increased intracranial pressure and the potential for mental impairment. Isolated craniosynostosis, however, is considered a benign condition primarily reconstructed for aesthetic purposes. A comparative analysis, to assess the differences between pre- and post operatory cerebral perfusion of patients who underwent surgery for simple cranisynostosis, was performed using single positron emission computedtomography ''SPECT'' Images. Cerebral blood flow studies were performed using "9"9"mTc-HMPAO SPECT in children with simple cranisynotoses. The subjects were 8 children with craniosynostosis (age, 2 months-9 years). Preoperative revealed regional hypovascularity in the cerebral hemisphere in 5 cases (62%). In 6 patients the cerebral blood flow normalized or increased after craniofacial reconstruction. We demonstrated the presence of regional hypovascularity in the cerebral ...
The diagnostic imaging findings in hepatic amoebiasis and the capabilities of percutaneous drainage have already been described but some debate is open on both diagnosis and treatment. It is reported the experience with the ultrasound (US) and ComputedTomography (CT) studies of the hepatic amoebic abscess and its management. [Italian] I reperti con diagnostica per immagini nell'amebiasi epatica e le possibilita' del drenaggio percutaneo sono stati gia' illustrati; esistono tuttavia controversie sul piano sia diagnostico che terapeutico. Obiettivo di questo lavoro e' quello di riportare l'esperienza personale nella diagnostica con ecografia e tomografia computerizzata (TC) e nel trattamento degli ascessi amebici del fegato.
Forty resected cases of intrahepatic cholangiocarcinoma were classified into four types according to the gross appearance; type I: mass forming type (n=8), type II: mass forming with periductal infiltrating type (n=20), type III: periductal infiltrating type (n=9) and type IV: intraductal growth type (n=3). Diagnostic features of these four types were studied. Peripheral enhancement was a common angiographic feature and tumor stains were recognized in 88%, 20%, 0%, 33%, respectively. Angiography and dynamic computedtomography (D-CT) were useful in differential diagnosis with hepatocellular carcinoma. Accuracy rate in diagnosis of portal vein involvement by angiography and D-CT was 82% and 91%, respectively. MRI was more useful in tumor detection than D-CT in cases with attenuation difference, in 55% of type II and in 75% of type III. Increase of arterial involvement, biliary tract involvement and portal vein involvement, incidence of lymph ...
The authors describe the different types of postoperative carcinoma recurrences, as seen on CT examinations of the chest, in 38 patients who underwent different surgical procedures for bronchogenic carcinoma (12 pneumonectomies, 22 lobectomies, 2 segmentectomies, and 2 atypical resections). The recurrences were classified as follows: 1) recurrence in the bronchial stump; 2) limph node enlargement; 3) recurrence in the thoracic wall; 4) recurrence in the residual lobe; 5) pleural effusion; 6) nodule in the contralateral lung. The CT findings, Correlated with those from plain chest radiographs and clinical simptoms, indicate a higher incidence of recurrences in the hilar region, either in the bronchial stump or as node after total and subtotal resection are separately analyzed. While after pneumonectomy plain chest radiographs fail to demonstrate the recurrence in most cases, so that CT is nearly always mandatory, after subtotal resection the diagnostic accuracy of conventional radiology ...
CT and MRI of acquired abnormalities of the inner ear and cerebello-pontine angle present themselves with very typical findings. The imaging should be adapted to the pathology looked for and either CT or MRI should be used alone or in combination.CT, especially high resolution CT (HRCT), provides an excellent bone contrast, while MRI has a much superior soft tissue contrast. Acute inflammatory changes of the inner ear are solely depicted by contrast-enhanced MRI. HRCT excellently depicts osseous changes of the inner ear and cerebellopontine angle such as chronic ossifying labyrinthitis occurring after acute labyrinthitis, otosclerotic or traumatic changes. Tumorous changes not yielding to bony changes are best delineated by MRI. Posttraumatic hemorrhage and chronic fibrotic changes within the labyrinth are depicted by MRI, only. In conclusion HRCT and MRI are excellent methods to delineate acquired abnormalities of the inner ear and cerebello-pontine angle. HRCT best depicts osseous ...
CT scans were performed on 25 patients suspected of sustaining ranal trauma. The utility of CT in both detecting renal damage and appraising the gravity of injuries was assessed. Nowadays, in fact, nephrectomy or reserved for lesions devastanting the kidney parenchyma or rupturing the renal pedicle; so it is very important to identyfy both the purposes of a better planned therapeutic approach. CT does both, being more accurate than urography in the detection of renal fractures, intra or extraparenchymal hematomas and contrast media extravasation. Urography very often shows aspecific lesion patterns and sometimes it is also falsely negative. In the present series CT was more reliable than angiography itself, particulary in the diagnosis of extra-renal hematic collections, contrast media extravasation and injuries to the other abdominal organs. Although CT may arouse the suspicion of and sometimes correctly diagnose vascular lesions, such as renal infarction, angiography remains the ...
This study was aimed at evaluating CT sensitivity in identifying the signs of pulmonary cystic fibrosis (CF). The chests of 39 patients (16 males and 23 females, mean age 19.1 years) were examined by CT: all patients had been given a clinical score according to Schwachman and Kulckzycki criteria. Thickened bronchial walls were observed in all cases, which are typical of peribronchitis. Bronchiectases were present in 87% of cases; their extent, pattern and localization were exactly shown on CT scans. Bronchoceles were seen on CT scans in 64% of patients; less frequent was the finding of atelectases and subpleural bullous emphysema. In a great number of patients (64% and 82%, respectively) pleural thickening and hilar adenopathy were demonstrated on CT scans. In conclusion, our results confirm CT as a more sensitive method than conventional radiography to identify and locate the signs of pulmonary CF. The early identification of the lesions of high prognostic value, since the early ...
Small bowel obstructions can be distinguished into more simple and closed loop obstructions. The latter is a more severe condition which is often complicated by strangulation with vascular impairment, edema and intramural and mesenteric hemorrhage. Consequent arterial insufficiency rapidly leads to ischemia, infarction and necrosis. The radiologist plays a role in the early recognition of the closed loop obstruction and of any sign of strangulation. The role of CT in the diagnosis and workup of patients with suspected intestinal occlusion has been analyzed in the literature with reported 63% sensitivity, 78% specificity and 66% accuracy. CT is also capable of revealing the causes of occlusion in 73-95% of cases. The above CT signs allow to identify closed loop obstruction and also small bowel strangulation, thus supplying a valuable contribution to diagnosis and accurate preoperative evaluation. The conclusion is that CT can accurately demonstrate the presence of closed loop ...
The authors present a comparison between the diagnostic accuracy of ComputedTomography (CT) and Magnetic Resonance Imaging (MRI) in the articular pathologies of the knee. CT and MRI were performed in 30 patients who subsequently underwent surgery. CT and MRI results were compared on three bases: technique, definition of normal anatomy, and diagnostic accuracy. CT allowed a standardization of the technique, while MRI was superior in defining normal anatomy - especially in the study of capsulo-ligamentous structures. In all cases the use of both CT and MRI allowed a correct diagnosis, showing the site, extent and gravity of the lesion. CT proved to be superior to MRI in 4 cases, while MRI corrected CT diagnosis in 11 cases; in 15 patients both techniques had the same diagnostic accuracy. Meniscal tears were better identified by CT, while MRI was superior in the detection of ligamentous lesions and in the characterization of PVNS and tendinitis ...
Neutron radiography and neutron radioscopy are rapidly becoming the valuable tools for nondestructive testing and basic research. The Phoenix Memorial Laboratory has developed a neutron facility capable of both film neutron radiography and real time neutron radioscopy, and has used this facility to study several phenomena of interest to the researchers in many areas. Neutrons can be used for imaging the phenomena that X-ray cannot image, such as the presence, absence or movement of hydrogenous materials inside metals such as aluminum or steel. There are three basic methods for obtaining images using neutrons: high resolution film neutron radiography, real-time neutron radioscopy and transfer film neutron radiography. The neutron radiography facility at Phoenix Memorial Laboratory, the neutron radioscopic imaging systems, the neutron radiographic detectors, lubrication studies, spray imaging, flow in porous media, three-dimensional computer-reconstructed neutron ...
Objective The aim of this study was to analyze the clinical results of our adaptive radiation therapy scheme of a two-step intensity-modulated radiotherapy (IMRT) method for nasopharyngeal cancer (NPC) at Kinki University Hospital. Methods Between 2000 and 2007, 35 patients with Stage I-IVB NPC treated by IMRT were included. For all patients, treatment-planning computedtomography was done twice before and during IMRT to a total dose of 60-70 Gy/28-35 fractions (median 68 Gy). Chemotherapy (cisplatin 80 mg/m2/3 weeks x 1-3 courses) was given concurrently with IMRT for 31 patients. Results The 3- and 5-year overall survival rates for the 31 patients treated with concurrent chemotherapy were 88% and 83%, respectively. The 3- and 5-year loco-regional control rates for the 31 patients were 93%...
A review of current daylighting design tools indicates that over 30 tools are now available, including nomographs, protractors, overlays, and programs for micro-, mini-, and mainframe computers. Computer-based tools allow testing and analyzing of more design alternatives under a wider variety of conditions than was previously practical with slower techniques, but they have not fundamentally changed the information available to the design professional. These tools are applicable to certain limited functions of the design process and do not address the varying information needs of the designer at various points in the design process. We describe a concept for a computer-based building envelope design tool that is structured to overcome many of the limitations of the existing tools. The tool would address daylighting design in the context of the overall building envelope design, covering a range of environmental quality issues ...
AIM: To assess the impact of the introduction of a computedtomography (CT) imaging protocol for multi-trauma patients on the workload, overall diagnostic yield, and effect on detection of cervical spine injury and pneumothorax. METHOD: Between February 1997 and April 2004, all patients presenting acutely to the Emergency Department (ED) with haemodynamically stable trauma (Abbreviated Injury Scale 3 or more) involving more than two body systems were imaged with a comprehensive pre-set helical CT protocol (including non-contrast head, cervical spine: cranio-cervical and cervico-thoracic junctions; and oral and intravenous contrast-enhanced thoracic, abdomen and pelvis) after initial triage and a standard trauma series of radiographs (chest, lateral C-spine and pelvis). Diagnosis of cervical spine fracture and pneumothorax was noted before and after the CT protocol was carried out and findings from all studies were recorded prospectively. ...
Patients with heterotaxy syndrome often have complex cardiac and extracardiac anomalies requiring further detailed diagnostic evaluation. They often present severe cardiac failure early in life. Newer radiological modalities in the form of spiral computedtomography (CT) and three-dimensional reconstruction of spiral CT allow clear definition of the anatomy of these anomalies. A 59-year-old woman was diagnosed with polysplenia and multiple anomalies in an abdominal ultrasonography (US) during a control medical examination due to a trivial dietary mistake. She was then referred to our institution for further examination of these anomalies and an additional thoraco-abdominal computedtomography (CT) examination. The patient was totally asymptomatic at the time of admission. There was no significant past history and no abnormal laboratory data. We performed abdominal, pelvic and thoracic CT examinations ...
Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: (1) conventional radiography (CXR), (2) low kV conventional radiography (Low), (3) Fuji computed radiography (FCR), (4) bone images with conventional singles exposure energy subtraction (ES) and (5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, images of 42 lung nodules (21 calcified lung nodules and 21 non-calcified nodules), in ...
Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: 1) conventional radiography (CXR), 2) low kV conventional radiography (Low), 3) Fuji computed radiography (FCR), 4) bone images with conventional singles exposure energy subtraction (ES) and 5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, images of 42 lung nodules (21 calcified lung nodules and 21 non-calcified nodules), in ...
An outline is given of time-dependent wavepacket methods as applied to calculations of molecular collisions with solid surfaces. The methods reviewed include numerical integration algorithms for the time-dependent Schroedinger equation, semiclassical wavepacket treatments, and approximations that treat some of the degrees-of-freedom quantum-mechanically and others classically. The computational and numerical characteristics of these methods are discussed, with emphasis on their particular advantages and relevance in the context of certain molecule/surface scattering problems. For the semiclassical and mixed quantal-classical treatments, the approximation errors and their physical origins are discussed. For the quantum wavepacket techniques a numerical error analysis is presented. The computational efficiency of the various algorithms is considered and examined in the context of several applications. The main focus is on diffractive scattering ...
We describe a stochastic inversion method for mapping subsurface regions where the electrical resistivity is changing. The technique combines prior information, electrical resistance data and forward models to produce subsurface resistivity models that are most consistent with all available data. Bayesian inference and a Metropolis simulation algorithm form the basis for this approach. Attractive features include its ability to: (1) provide quantitative measures of the uncertainty of a generated estimate and, (2) allow alternative model estimates to be identified, compared and ranked. Methods that monitor convergence and summarize important trends of the posterior distribution are introduced. Results from a physical model test and a field experiment were used to assess performance. The stochastic inversions presented provide useful estimates of the most probable location, shape, and volume of the changing region, and the most likely resistivity change. The proposed ...
A series of 27 reflood experiments has been carried out in a full-length electrically heated rod bundle facility. The primary objective of these tests was to study the effects of a simultaneous upper plenum and downcomer coolant injection and to provide data for the verification of computer codes. The experimental results indicate that an upper plenum injection alone cools the test rods slowly, a simultaneous coolant injection to the downcomer improves cooling significantly, and a downcomer injection alone cools the test rod bundle best if the total value of the coolant flow rate is the same in these three different cases. If the coolant injected to the upper plenum increases the total flow rate, the quench time of the test rods decreases at all elevations. Quenching time and clad temperature histories calculated with the computer codes NORCOOL-I and FLOOD4 are in a reasonable quantitative agreement with experiments in the ...
Metabolic carbon labelling experiments enable a large amount of extracellular fluxes and intracellular carbon isotope enrichments to be measured. Since the relation between the measured quantities and the unknown intracellular metabolic fluxes is given by bilinear balance equations, flux determination from this data set requires the numerical solution of a nonlinear inverse problem. To this end, a general algorithm for flux estimation from metabolic carbon labelling experiments based on the least squares approach is developed in this contribution and complemented by appropriate tools for statistical analysis. The linearization technique usually applied for the computation of nonlinear confidence regions is shown to be inappropriate in the case of large exchange fluxes. For this reason a sophisticated compactification transformation technique for nonlinear statistical analysis is developed. Statistical analysis is then performed by computing ...
The purpose of this study was to determine the thickness of the macula and the retinal nerve fiber layer (RNFL) in Japanese subjects by Stratus optical coherence tomography (OCT), and to compare the...Full Text Available
ObjectiveThe aim of this study was to evaluate the utility of volume-rendered helical computerized tomography (CT) angiography focusing tracheostomy tube and innominate artery for...Full Text Available
PurposeTo describe ocular findings for a 34-year-old man with chronic solar retinopathy using high-speed ultrahigh-resolution (UHR) optical coherence tomography (OCT).Full Text Available
Purpose.To investigate the characteristics of a spectral-domain optical coherence tomography (SD-OCT) image phenomenon known as the mirror artifact, calculate its prevalence, analyze...Full Text Available
The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y...Full Text Available
We present a method to make phantoms of coronary arteries for intravascular optical coherence tomography (IV-OCT). The phantoms provide a calibrated OCT response similar to the layered structure of...Full Text Available
The central benzodiazepine receptor tracer [N-methyl-"1"1C]iomazenil (Ro 16-0154) was synthesized by alkylation of the desmethyl precursor noriomazenil with ["1"1C]methyl iodide. The ["1"1C]CH_3I (prepared by reduction of ["1"1C]CO_2 with LiAlH_4 followed by reaction with HI) was reacted with noriomazenil inN,N -dimethylformamide and Bu_4N"+OH"- for 1 min at 80 deg. C and purified by HPLC (C_1_8, 34% CH_3CN/H_2O, 7 mL/min). The product was obtained with synthesis time 35 #+-# 5 min (mean #+-# SD, n = 7), radiochemical yield (EOB) 36 #+-# 16%, radiochemical purity 99 #+-# 1%, and specific activity 5100 #+-# 2800 mCi/#mu#mol. Absorbed radiation doses were calculated from previously acquired human biodistribution data. The urinary bladder wall received the highest dose (0.099 mGy/MBq) for 4.8 h voiding interval and the effective dose equivalent was 0.015 mSv/MBq. After i.v. injection of ["1"1C]iomazenil in an adult baboon or healthy human volunteer, radioactivity accumulated in the cortex ...
Radioimmunotherapy (RIT) is a new treatment option for patients with non-Hodgkin lymphoma (NHL). Response to RIT currently remains difficult to predict using conventional prognostic factors and could be refined using functional imaging. The goal of this work is to evaluate the value of 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in predicting response to Yttrium 90-labeled monoclonal antibodies for patients with NHL. Thirty-five patients with NHL who had undergone 18F-FDG PET prior to RIT with either 90Y-ibritumomab tiuxetan (group A; n=17) or 90Y-epratuzumab tetraxetan (group B; n=18) were included in this retrospective study. Four functional criteria were determined for each tumour lesion in a given patient: maximum and mean standard uptake values (SUVmax and SUVmean), functional lesion volume (LVol) and total lesion glycolysis (TLG, product of the volume and the SUVmean). For each patient, we determined highest SUVmax and SUVmean, cumulative ...
(3H)Cyclofoxy (CF: 17-cyclopropylmethyl-3,14-dihydroxy-4,5-alpha-epoxy-6-beta-fluoromorp hinan) is an opioid antagonist with affinity to both mu and kappa subtypes that was synthesized for quantitative evaluation of opioid receptor binding in vivo. Two sets of experiments in rats were analyzed. The first involved determining the metabolite-corrected blood concentration and tissue distribution of CF in brain 1 to 60 min after i.v. bolus injection. The second involved measuring brain washout for 15 to 120 s following intracarotid artery injection of CF. A physiologically based model and a classical compartmental pharmacokinetic model were compared. The models included different assumptions for transport across the blood-brain barrier (BBB); estimates of nonspecific tissue binding and specific binding to a single opiate receptor site were found to be essentially the same with both models. The nonspecific binding equilibrium constant varied modestly in different brain ...
Attention deficit hyperactivity disorder (ADHD) is a psychiatric disorder in childhood that is known to be associated with dopamine dysregulation. In this study, we investigated dopamine transporter (DAT) density in children with ADHD using iodine-123 labelled N-(3-iodopropen-2-yl)-2β-carbomethoxy-3β-(4-chlorophenyl) tropane ([{sup 123}I]IPT) single-photon emission tomography (SPET) and postulated that an alteration in DAT density in the basal ganglia is responsible for dopaminergic dysfunction in children with ADHD. Nine drug-naive children with ADHD and six normal children were included in the study. We performed brain SPET 2 h after the intravenous administration of [{sup 123}I]IPT and carried out both quantitative and qualitative analyses using the obtained SPET data, which were reconstructed for the assessment of the specific/non-specific DAT binding ratio in the basal ganglia. We then investigated the correlation ...
Involvement of the dopaminergic system has been suggested in patients suffering from attention deficit hyperactivity disorder (ADHD) since the symptoms can be successfully treated with methylphenidate, a potent blocker of the dopamine transporter (DAT). This study reports the findings on the status of the DAT in adults with ADHD before and after commencement of treatment with methylphenidate, as measured using [{sup 99m}Tc]TRODAT-1. Seventeen patients (seven males, ten females, aged 21-64 years, mean 38 years) were examined before and after the initiation of methylphenidate treatment (3 x 5 mg/day). All subjects were injected with 800 MBq [{sup 99m}Tc]TRODAT-1 and imaged 3 h p.i. Single-photon emission tomography (SPET) scans were acquired using a triple-headed gamma camera. For semi-quantitative evaluation of the DAT, transverse slices corrected for attenuation were used to calculate specific binding in the striatum, with the cerebellum used ...
This report to the Nuclear Regulatory Commission (NRC) describes the development and application of a methodology to systematically and quantitatively assess predictive uncertainty in groundwater flow and transport modeling that considers the combined impact of hydrogeologic uncertainties associated with the conceptual-mathematical basis of a model, model parameters, and the scenario to which the model is applied. The methodology is based on a n extension of a Maximum Likelihood implementation of Bayesian Model Averaging. Model uncertainty is represented by postulating a discrete set of alternative conceptual models for a site with associated prior model probabilities that reflect a belief about the relative plausibility of each model based on its apparent consistency with available knowledge and data. Posterior model probabilities are computed and parameter uncertainty is estimated by calibrating each model to observed system behavior; prior ...
Dosimetric studies in 80 patients examined with the tomographic device 'Somatom' are reported. The gonad doses are compared to those of conventional radiographic techniques.
Ultrasound tomography is an attractive imaging method for the detection of breast cancer. The complex anatomy of the breast with its different spatial scales and material property contrasts make accurate reconstructions very challenging. This paper proposes a hybrid approach whereby Travel-of-Flight and Diffraction Tomography are combined together to achieve high-resolution and high-accuracy sound-speed reconstructions. The method is validated with several numerical phantoms.
We are developing a laterally variable velocity model of the crust and upper mantle across Eurasia and North Africa to reduce event location error by improving regional travel-time prediction accuracy. The model includes both P and S velocities and we describe methods to compute travel-times for Pn, Sn, Pg, and Lg phases. For crustal phases Pg and Lg we assume that the waves travel laterally at mid-crustal depths, with added ray segments from the event and station to the mid crustal layer. Our work on Pn and Sn travel-times extends the methods described by Zhao and Xie (1993). With consideration for a continent scale model and application to seismic location, we extend the model parameterization of Zhao and Xie (1993) by allowing the upper-mantle velocity gradient to vary laterally. This extension is needed to accommodate the large variation in gradient that is known to exist across Eurasia and North African. Further, we extend the linear travel-time calculation ...
A fast and accurate segmentation of organs at risk, such as the healthy colon, would be of benefit for planning of radiotherapy, in particular in an adaptive scenario. For the treatment of pelvic tumours, a great challenge is the segmentation of the most adjacent and sensitive parts of the gastrointestinal tract, the sigmoid and descending colon. We propose a semi-automated method to segment these bowel parts using the fast marching (FM) method. Standard 3D computedtomography (CT) image data obtained from routine radiotherapy planning were used. Our pre-processing steps distinguish the intestine, muscles and air from connective tissue. The core part of our method separates the sigmoid and descending colon from the muscles and other segments of the intestine. This is done by utilizing the ability of the FM method to compute a specified minimal energy functional integrated along a path, and thereby extracting the colon ...
As an alternative to surgery, endovascular therapy with stent grafts has become the second main treatment option for infrarenal abdominal aortic aneurysms. Unlike surgery, endovascular treatment with stent grafts is also applicable in patients unfit for open repair. Despite current improvements in endovascular repair devices, significant anatomic barriers still exclude this technique for a large number of patients. Computedtomography, magnetic resonance imaging, and ultrasound are essential for diagnostics, preintervention planning, and postintervention follow-up of abdominal aneurysms treated with stent grafts. This review covers etiology, pathology, and diagnostic aspects. Materials and methods for endovascular treatment of abdominal aortic aneurysms are presented in detail, and clinical results and complications are discussed. (orig.) [German] Die endovaskulaere Therapie des infrarenalen Bauchaortenaneurysmas hat sich als Alternative zur ...
The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film arteriogram even with a half concentration of ...
The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film arteriogram even with a half concentration of ...
The objective was to characterize imaging findings of benign notochordal cell tumors (BNCTs). Clinical and imaging data for 9 benign notochordal cell tumors in 7 patients were reviewed retrospectively. Conventional radiographs (n = 9), bone scintigrams (n = 2), computed tomographic images (n = 7), and magnetic resonance images (n = 8) were reviewed. Eight of the 9 lesions were stained with hematoxylin-eosin and microscopically examined. There were 3 male and 4 female patients with an age range of 22 to 55 years (average age, 44 years). Two patients had two lesions at different sites. The lesions involved the cervical spine in 4 patients, the lumbar spine in 2, the sacrum in 2, and the coccyx in 1. The most common symptom was mild pain. The lesions of 2 patients were found incidentally during imaging studies for unrelated conditions. Five patients underwent surgical procedures. One patient died of surgical complications. All other patients have been well without ...
Computedtomography would be a better method to detect and characterize a Thorotrast-induced liver tumour. The selective opacification of the RES by Thorotrast creates an intrinsic opacification of the liver similar in effect to contrast agents being evaluated for liver CT, such as ethoioidized oil emulsion. The computed tomographic appearance of Thorotrast-associated cholangiocarcinoma is usually a large, inhomogenous mass composed of disordered area of tissue of high density due to Thorotrast deposits, and of very low density. Thorotrast-induced cholangiocarcinoma originates in the peripheral biliary tree suprounding the highest mean concentration of Thorotrast deposition, so that visible soft tissue masses in the higher density spots in the liver are not produced in the early stage. The tendency for the opacity of the liver to decrease slowly with time and result in an uneven trabeculation and high density spots suggests ...
Network tomography aims at inferring internal network characteristics based on measurements at the edge of the network. In loss tomography, in particular, the characteristic of interest is the loss rate of individual links. There is a significant body of work dedicated to this problem using multicast and/or unicast end-to-end probes. Independently, recent advances in network coding have shown that there are several advantages from allowing intermediate nodes to process and combine, in addition to just forward, packets. In this paper, we pose the problem of loss tomography in networks that have network coding capabilities. We design a framework for estimating link loss rates, which leverages network coding capabilities and we show that it improves several aspects of tomography, including the identifiability of links, the tradeoff between estimation accuracy and bandwidth efficiency, and the complexity of ...
The evaluation of biological markers is recognized as necessary to the future of toxicology, epidemiology, and quantitative risk assessment. For biological markers to become widely accepted, their validity...Full Text Available
Quantitative microscopy has been extensively used in biomedical research and has provided significant insights into structure and dynamics at the cell and tissue level. The entire procedure...Full Text Available
High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions can be quantitatively evaluated thermoluminescent dosimeter (TLD) chips with a dimension of 1/8 and film dosimetry with a spatial resolution of <1 mm used to measure the radiation ...
We describe the development of a fully coupled climate model configuration where the Community Climate System Model (CCSM) has been coupled with the VERDE (Visualizing Energy Resources Dynamically on the Earth) analysis modules that compute the response of the electric grid to temperature drivers. The VERDE model includes datasets characterizing the 26,500 sub-stations and 6,000 power generation stations fuel mix, efficiency, service areas, and future performance and these have been geo-located on a 1.4 degree latitude by 1.4 degree longitude CCSM grid (T85). The total electric customers have been computed using conversions derived from economic structure and population data. The carbon emissions per customer and the power generation in megawatts electric (MWe) have also been placed on reconciled 1 km, 4 km and the T85 climate model grid. The CCSM temperature for the present and future have been extracted from the climate model output and ...
The role of high-resolution computedtomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. Postoperative HRCT depicted bony erosions ...
Purpose: To report on the nephron-sparing, percutaneous ablation of a large renal cell carcinoma by combined superselective embolization and percutaneous radiofrequency ablation. Materials and Methods: A 5 cm renal cell carcinoma of a 43-year-old drug abusing male with serologically proven HIV, hepatitis B and C infection, who refused surgery, was superselectively embolized using microspheres (size: 500 - 700 {mu}m) and a platinum coil under local anesthesia. Percutaneous radiofrequency ablation using a 7F LeVeen probe (size of expanded probe tip: 40 mm) and a 200 Watt generator was performed one day after transcatheter embolization under general anesthesia. Results: The combined treatment resulted in complete destruction of the tumor without relevant damage of the surrounding healthy renal tissue. The patient was discharged 24 hours after RF ablation. No complications like urinary leaks or fistulas were observed and follow up CT one day and 4 weeks after the radiofrequency ...
Variations in skin perfusion are easily detected by laser speckle contrast maps, but a robust interpretation of the information has been lacking. We show that multiple-exposure laser speckle methods produce the same spectral information as laser Doppler methods when applied to targets with embedded moving scatterers. This enables laser speckle measurements to be interpreted more quantitatively. We do this by using computer simulation of speckle data, and by experimental measurements on Brownian motion and skin perfusion using a laser Doppler system and a multiple-exposure laser speckle system. The power spectral density measurements of the light fluctuations derived using both techniques are exactly equivalent. Dermal perfusion can therefore be measured by laser Doppler or laser speckle contrast methods. In particular, multiexposure laser speckle can be rapidly processed to generate a full-field map of the perfusion index proportional to the ...
An automated Time Resolved Aerosol Collector (TRAC) has been developed for sequential sampling of field-collected aerosols for laboratory-based Computer Controlled Scanning Electron Microscopy/Energy Dispersed X-ray (CCSEM/EDX) single particle analysis. The collector is optimized for use of grid-supported 20 nm carbon films as deposition substrates. The carbon films have low enough X-ray background to permit EDX analysis down to 0.1-0.2 ?m particles, including detection of low-Z elements: C, N, & O. The TRAC provides unattended sampling onto a set of 151 individual grids, at sequential time intervals as short as 1 min. After collection, the samples are sealed and refrigerated pending analysis. The utility of the TRAC-CCSEM/EDX approach is exemplified using the aerosol samples collected during the Texas 2000 Air Quality Studies (Aug. 15 ? Sept. 15, 2000). We are able to quantitatively follow the time evolution in the relative contribution of ...
To address the need for integrated models of advanced power generation systems and for improved analysis techniques, the US Department of Energy (DOE), through the Morgantown Energy Technology Center (METC), has supported the development of performance, emissions, and cost models of several advanced power generation systems, including integrated gasification combined cycle (IGCC), externally-fired combined cycle (EFCC) and pressurized fluidized bed combustion (PFBC) concepts. Simultaneously, numerical methods for simulation of uncertainties and optimization of process flowsheets have been implemented in the DOE`s public version of ASPEN. The new process models and computational capabilities have been applied to demonstrate the benefits of quantitative approaches to dealing with uncertainty and for optimizing technologies in the face of uncertainty. This paper focuses on modeling and assessment of the EFCC system concept. The purpose of the ...
Biodiesel made from vegetable oil is among the most desirable of renewable energy sources because it can be a substitute for diesel oil. However, biodiesel from soybean or corn can be confronted with a food crisis. Microalgae is a new biodiesel source which contains high oil lipids with a high growth rate, and which also offers value-added products from the residue, such as cosmetics, health functional food or pharmaceuticals. Microalgae are best cultivated in photo-bioreactors (PBRs) where light, nutrients, carbon dioxide and temperature can be controlled. Despite the current availability of PBRs, only a few can be practically used for mass production. Computational fluid dynamics (CFD) was used in this study to design an optimum bubble-column PBR for mass production of microalgae. Multi-phase models including bubble movement, meshes and time step independent tests were considered to develop the 3-dimensional CFD model. Particle Image Velocimetry (PIV) tests were ...
Computer programs have been developed to define the temperature increase which would be needed to bring deep-ocean water into density equilibrium with surface water for locations where data are available. A series of continuous-flow studies on phytoplankton blooms resulting from mixtures of 80 percent deep and 20 percent surface water in 2000-liter concrete culturing vessels (''reactors'') has been completed. A quantitative determination of nutrient utilization and flow through a combined primary and secondary trophic level system has been completed. This study utilized the clam Tapes semidecussata, fed from phytoplankton grown in 80 percent deep and 20 percent surface water. An analysis of the fate of the deep water discharged from a floating OTEC plant indicates that horizontal containment of the resulting deep water: surface water mixture is necessary if conditions optimal for open-sea mariculture are to ...
The Four years of the IMPACT, 'Integrated Modular Plant Analysis and Computing Technology', project Phase 1 have been completed. The verification study of Severe Accident Analysis Code SAMPSON prototype developed in Phase 1 was conducted in two steps. First, each analysis module was run independently and analysis results were compared and verified against separate-effect test data with good results. Second, with the Simulation Supervisory System, up to 11 analysis modules were executed concurrently in the parallel environment (currently, NUPEC uses IBM-SP2 with 72 process elements), to demonstrate the code capability and integrity. The target plant was Surry as a typical PWR and the initiation events were a 10-inch cold leg failure. The analysis is divided to two cases; one is in-vessel retention analysis when the gap cooling is effective (In-vessel scenario test), the other is analysis of phenomena event is extended to ex-vessel due to the Reactor Pressure Vessel ...
The uptake of sup(99m)Tc-methylenediphosphonate (MDP) in different parts of rat femur was simulated using a local three-space model for tracer transfer. The model consisted of bone blood, bone ECF-space and space for tracer deposition. The measured sup(99m)Tc-MDP concentration in the systemic blood and the local bone blood flow measured by /sup 131/I-macroaggregated albumin microspheres were used as input parameters. The measured blood flow values were 6.3, 3.1 and 15.3 ml/100 g/min for proximal, middle and distal femur, respectively. the model parameters that gave the best fit to measured sup(99m)Tc-MDP uptake curves in computer simulation showed that bone blood flow, volume of ECF-space, permeability surface area product and accretion constant from ECF-space to space for tracer deposition were highest in distal and lowest in middle femur. The values corresponded to peak extraction fractions of 0.38, 0.62, and 0.31 for proximal, middle and distal femur, ...
The uptake of sup(99m)Tc-methylenediphosphonate (MDP) in different parts of rat femur was simulated using a local three-space model for tracer transfer. The model consisted of bone blood, bone ECF-space and space for tracer deposition. The measured sup(99m)Tc-MDP concentration in the systemic blood and the local bone blood flow measured by "1"3"1I-macroaggregated albumin microspheres were used as input parameters. The measured blood flow values were 6.3, 3.1 and 15.3 ml/100 g/min for proximal, middle and distal femur, respectively. the model parameters that gave the best fit to measured sup(99m)Tc-MDP uptake curves in computer simulation showed that bone blood flow, volume of ECF-space, permeability surface area product and accretion constant from ECF-space to space for tracer deposition were highest in distal and lowest in middle femur. The values corresponded to peak extraction fractions of 0.38, 0.62, and 0.31 for proximal, middle and distal femur, respectively. ...
Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two detectors, respectively and the imaging quality of phantoms. Preliminary results showed that the system is ...
A first-principles task-based approach to the design of medical ultrasonic imaging systems for breast lesion discrimination is described. This study explores a new approximation to the ideal Bayesian observer strategy that allows for object heterogeneity. The new method, called iterative Wiener filtering, is implemented using echo data simulations and a phantom study. We studied five lesion features closely associated with visual discrimination for clinical diagnosis. A series of human observer measurements for the same image data allowed us to quantitatively compare alternative beamforming strategies through measurements of visual discrimination efficiency. Employing the Smith-Wagner model observer, we were able to breakdown efficiency estimates and identify the processing stage at which performance losses occur. The methods were implemented using a commercial scanner and a cyst phantom to explore development of spatial filters for systems with shift-variant ...
The accuracy of dose computation within the lungs depends strongly on the performance of the calculation algorithm in regions of electronic disequilibrium that arise near tissue inhomogeneities with large density variations. There is a lack of data evaluating the performance of highly developed analytical dose calculation algorithms compared to Monte Carlo computations in a clinical setting. We compared full Monte Carlo calculations (performed by our Monte Carlo dose engine MCDE) with two different commercial convolution/superposition (CS) implementations (Pinnacle-CS and Helax-TMS's collapsed cone model Helax-CC) and one pencil beam algorithm (Helax-TMS's pencil beam model Helax-PB) for 10 intensity modulated radiation therapy (IMRT) lung cancer patients. Treatment plans were created for two photon beam qualities (6 and 18 MV). For each dose calculation algorithm, patient, and beam quality, the following set of clinically relevant dose-volume ...
Computerized tomography of the adrenal glands was performed in 10 patients with Cushing's syndrome using a G.E. 8800 CT/T Body Scanner. The tomographic findings of unilateral adrenal masses in 4 patients were confirmed by surgery. In the remaining 6 patients, computerized tomography did not identify any masses, and both glands were well visualized and showed normal shape. In these patients, measurement of the adrenal glands revealed both normal (n=1) and enlarged glands (n=5). The findings of adrenalectomy (n=4) or transphenoidal surgery and follow-up (n=2) established the diagnosis of adrenal phyperplasia in all patients. (Author).
Purpose: To assess the prevalence, significance and practical value of two recently described CT signs of instable aneurysm: the crescent sign and the periluminal halo (a low-attenuating internal layer of the thrombus around the patent lumen). Material and methods: Among the CT examination performed in the last 5 years, they retrospectively selected the nonruptured aneurysms with a diameter exceeding 4 cm (no. = 93 average diameter 5.1 cm, unenhanced images in 28 cases and enhanced in 84) and the ruptured aneurysms (no. = 16, average diameter 6.7 cm, unenhanced images in 9 cases and enhanced in 9). They studied the prevalence of the crescent and halo sing, their relationship with the aneurysm diameter, and the effect of contrast enhancement. Results: The crescent sign was identified with a statistically significant prevalence in ruptured ( 37.5 % or cases) over asymptomatic aneurysms (5.5 %); the halo had the same frequency in the 2 groups (12.5 % and 9.5 %). Both signs were more ...
Tumor-targeted monoclonal antibodies (mAb) might be useful as diagnostic or therapeutic agents when linked to cytotoxic or imaging reagents. Our group is working to test this hypothesis by linking cytocidal and image-producing isotopes to mAb and testing the utility of the radioimmunoconjugates formed in animal model systems. Radioiodines were first employed for these purposes,but unfavorable nuclear properties (half-lives, #gamma#-ray and #beta#-particle energies) and chemical reactivity (deiodination in vivo) limit their utility. Labeling immunoproteins with metallic radionuclides offers more versatility in that the selection of potentially useful radiometals spans the periodic table.Of the metallic radionuclides with physical properties most suited for use with mAb in nuclear medicine, few are more available or desirable than those of bismuth ("2"1"2Bi) and lead ("2"0"3Pb, "2"1"2Pb), as listed in Table 1. "2"1"2Bi or "2"1"2Pb could serve as sources for highly cytocidal ...
Coronary angiography provides anatomical information whereas thellium myocardial scintigraphy measures resistive tissue perfusion. Because of this fundamental difference. The authors question the validity of using coronary angiography as the gold standard to judge thellium myocardial scintigraphy. The authors studied 20 patients undergoing elective percutaneous coronary angioplasty who fulfilled the following criteria: (1) history of chest pain; (2) angiographically significant single vessel disease (>50% stenosis); (3) no prior myocardial infarction. All patients underwent maximal exercise thallium single photon emission computedtomography (T1-SPECT). Tl-SPECT was scored visually according to a 0 to 3 scale (0=absent uptake; 1=markedly decreased uptake; 2=minimally decreased uptake; 3=normal uptake). Translesional gradient and percent stenosis were measured before and after angioplasty. The authors found that significant linear ...
There is extensive evidence that exposure to asbestos causes pulmonary parenchyma fibrosis, pleural disease, and malignant neoplasm in asbestos-exposed workers. However, few data concerning brake-lining workers are available in the literature. In this study, we aimed to assess the long-term effects of chrysotile asbestos exposure on lung function and the risk of asbestos-related diseases in brake-lining workers. Seventy-four asbestos-exposed workers who processed brake-lining products and 12 unexposed office workers were offered pulmonary function tests (spirometry and transfer actor) in 1992 and 1999. In 1999, the mean duration of asbestos exposure was 0.00#+-#4.07 and 11.02#+-#4.81 years (7-31 years) in non smoking and smoking asbestos workers, respectively. Transfer factor (T_L, CO) and transfer coefficient (K_C_O) decline were significant in the 7-year follow-up in both smoking and non smoking asbestos workers. However, lung function indices of he control group, whom were all ...
To study the utility of ultrasound and computedtomography (CT) in case of suspected appendicitis. To determine the diagnostic yield in terms of different clinical contexts and patient characteristics. to assess the costs and benefits of introducing these techniques and propose a protocol for their use. Negative appendectomies, complications and length of hospital stay in a group of 152 patients with suspected appendicitis who underwent ultrasound and CT were compared with those of 180 patients who underwent appendectomy during the same time period, but had not been selected for the first group: these patients costs for each group were calculated. In the first group, the diagnostic value of the clinical signs was also evaluated. The reliability of the clinical signs was limited, while the results with ultrasound and CT were excellent. The incidence of negative appendectomy was 9.6% in the study group and 12.2% in the control group. Moreover, ...
The purpose of this study was to evaluate the safety and efficacy of percutaneous ultrasound (US)-guided radiofrequency ablation (RFA) in patients with intrahepatic cholangiocarcinoma (ICCA) in a small, nonrandomized series. From February 2004 to July 2008, six patients (four men and two women; mean age 69.8 years [range 48 to 83]) with ICCA underwent percutaneous US-guided RFA. Preintervetional transarterial embolization was performed in two cases to decrease heat dispersion during RFA in order to increase the area of ablation. The efficacy of RFA was evaluated using contrast-enhanced dynamic computedtomography (CT) 1 month after treatment and then every 3 months thereafter. Nine RFA sessions were performed for six solid hepatic tumors in six patients. The duration of follow-up ranged from 13 to 21 months (mean 17.5). Posttreatment CT showed total necrosis in four of six tumors after one or two RFA sessions. Residual tumor was observed in two ...
The accurate staging of rectal carcinoma is very important for treatment planning. The histological data obtained from surgical specimens of 22 patients with rectal carcinoma were compared with pre-and postoperative endorectal US findings and with preoperative CT results. According to an adapted version of Astler and Coller classification, the different degrees of tumor spread into the rectal wall were represented as follows: stage A: 1 patient; stage B1: 5 patients; stage B2: 6 patients; stage C1: 1 patient; stage C2: 8 patients and stage D: 1 patient. Preoperative staging, based on the overall results of CT and US, was in agreement with histology in 19 of 22 cases. Individual analysis of US and CT results, in comparison with histological data, showed US staging accuracy to be 77.3% (17/22 patients). US accuracy in demonstrating tumor spread into the rectal wall (stages A, B1, C1) was 100% (7/7 patients); US was 70% accurate in lymph node detection (7/10 patients) and 93.3% accurate ...
Our aim was to investigate the diagnostic reliability of multidetector-row computedtomography (MDCT) for preoperative assessment of local tumoral spread in hilar cholangiocarcinoma. Thirteen of 30 consecutive patients with hilar cholangiocarcinoma who underwent surgery, excluding 17 patients who underwent biliary drainage or preoperative portal embolization, were retrospectively evaluated. Using MDCT systems of 4 detector rows or 16 detector rows, plain and dynamic contrast-enhanced images of three phases were obtained. Extent of tumor spread and lymph node metastasis were assessed with MDCT and compared with histopathological findings. The Bismuth-Corlette classification of hilar cholangiocarcinoma with MDCT were type I, 1 patient; type IIIa, 3 patients; type IIIb, 4 patients; and type IV, 5 patients; those with histopathological findings were type I, 1 patient; type IIIa, 2 patients; type IIIb, 4 patients; and type IV, 6 patients. One ...
The high sensitivity of CaSO{sub 4}: Dy as a thermoluminescent material is a great advantage when dealing with low dose levels, as in diagnostic radiology procedures. However, these kinds of dosemeters present a high energy dependence that must be precisely determined in the energy range of interest. Dosimetric pellets of CaSO{sub 4}: Dy are produced at IPEN since the end of the 80 Th decade. These pellets are produced in three forms: conventional CaSO{sub 4}: Dy (50 mg); thin CaSO{sub 4}: Dy (20 mg) and CaSO{sub 4}: Dy + 10% C (20 mg). The main applications of these dosemeters are in personal and environmental dosimetry. In this study, CaSO{sub 4}: Dy pellets produced at IPEN were evaluated in diagnostic radiology standard beams. These qualities are based on the IEC 61267 standard, and they were established at an industrial X-ray system Pantak/Seifert, model ISOVOLT 160HS. Former studies evaluated CaSO{sub 4}: Dy of different origins in diagnostic beams. In this study, a large energy ...
Osteonecrosis (ON) of the hip joint remains an unsolved therapeutical problem. Diagnosis of ON of the hip has been improved by the technical progress of imaging modalities and better understanding pathomorphology. Over a long period only plain radiographs have been available. Scintigraphy and computedtomography contributed to differential diagnosis and early detection of bone necrosis. Diagnosis in an early reversible stage is of importance. Understanding of pathophysiology, early diagnosis and therapeutical approach has been significantly improved by MR imaging. Using the ARCO system all imaging modalities and their diagnostic viability are described in the five ARCO stages. At the end a diagnostic algorithm will be proposed. (orig.) [German] Die Osteonekrose des Hueftgelenks (ON) stellt noch immer ein nicht geloestes therapeutisches Problem dar. Die diagnostischen Moeglichkeiten bei der ON wurden in den letzten Jahren durch technische ...
Mucociliary transport so critical in nasal, paranasal sinus, and middle ear physiology is impaired in chronic sinsusitis and otitis media by factors such as increased mucus viscoelasticity, decreased ciliary area, and primary or secondary ciliary immotility. We reviewed the pathophysiology of primary ciliary dyskinesia, otitis media with effusion, chronic sinusitis, and allergic rhinitis in terms of mucociliary transport. Subjects with primary ciliary dyskinesia may experience recurrent middle ear infection, chronic airway infection, predominantly lower-lobe bronchiectasis, male sterility, or situs inversus. Primary ciliary dyskinesia is sometimes difficult to diagnose in cases without situs inversus. Nasal nitric oxide concentration in such patients decreases, although why is unclear. Mutations may involve dynein arm intermediate chain 1 (DNAI1) or dynein arm heavy chain 5 (DNAH5). Mucociliary clearance decreases more in those with otitis media with effusion than in those without, due ...
The Anisotropic Analytical Algorithm (AAA) is a new pencil beam convolution/superposition algorithm proposed by Varian for photon dose calculations. The configuration of AAA depends on linear accelerator design and specifications. The purpose of this study was to investigate the accuracy of AAA for an Elekta SL25 linear accelerator for small fields and intensity modulated radiation therapy (IMRT) treatments in inhomogeneous media. The accuracy of AAA was evaluated in two studies. First, AAA was compared both with Monte Carlo (MC) and the measurements in an inhomogeneous phantom simulating lung equivalent tissues and bone ribs. The algorithm was tested under lateral electronic disequilibrium conditions, using small fields (2x2 cm"2). Good agreement was generally achieved for depth dose and profiles, with deviations generally below 3% in lung inhomogeneities and below 5% at interfaces. However, the effects of attenuation and scattering close to the bone ribs were not fully taken into ...
This study was performed to evaluate the diagnostic usefulness of double-phase Tc-99m MIBI parathyroid scintigraphy with single photon emission computedtomography (SPECT) in patients with hyperparathyroidism. We also evaluated the relationship between Tc-99m MIBI uptake and oxyphil cell contents in parathyroid glands. The subjects were 28 parathyroid glands of 10 patients who underwent Tc-99m MIBI parathyroid scintigraphy and parathyroidectomy for clinically suspected hyperparathyroidism. Early and delayed pinhole images were obtained at 15 minutes and 2 hours after injection of Tc-99m MIBI, and SPECT images were followed. The weight and oxyphil cell contents of parathyroid tissue were obtained from pathologic specimen, and the scintigraphic findings were compared with histopathology. In surgical histopathology, 6 parathyroid adenomas and 9 parathyroid hyperplasias were confirmed. The sensitivity, specificity, and positive predictive value of ...
Iodixanol is a new nonionic dimer, isotonic with blood at all clinically relevant concentrations. Iodixanol (270 mg I/ml) was compared in a double-blind, randomized, parallel-group, phase-III study to the monomeric nonionic iohexol (300 mg I/ml) for evaluation of safety, tolerability and radiographic efficacy during cerebral CT. One hundred adult patients scheduled to undergo contrast-enhanced cerebral CT were randomly allocated to receive either iodixanol or iohexol. All completed the trial. Safety was evaluated by recording discomfort and other adverse events, tolerance by assessing intensity and incidence of discomfort. Radiographic efficacy was assessed from the diagnostic information and the radiographic density. No serious adverse events occurred. One patient (2 %) in the iodixanol group and one patient (2 %) in the iohexol group experienced a transient reddening at the neck and lower neck-line, respectively. Both contrast agents were well tolerated. One patient (2 %) in the ...
The aim of this study was to evaluate imaging features of different coronary artery stents during multislice CT Angiography (MSCTA). Nineteen stents made of varying material (steel, nitinol, tantalum) and of varying stent design were implanted in plastic tubes with an inner diameter of 3 mm to simulate a coronary artery. The tubes were filled with iodinated contrast material diluted to 200 Hounsfield units (HU), closed at both ends and positioned in a plastic container filled with oil (-70 HU). The MSCT scans were obtained perpendicular to the stent axes (detector collimation 4 x 1 mm, table feed 2 mm/rotation, 300 mAs, 120 kV). Axial images and multiplanar reformations were evaluated regarding artifact size, lumen visibility, and intraluminal attenuation values. Artifacts characterized by artifactual thickening of the stent struts leading to apparent reduction in the lumen diameter and increased intraluminal attenuation values were observed in all cases. The stent lumen was totally ...
Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computedtomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following ...
Graft copolymers of methyl methacrylate and biodegradable, biocompatible bacterial poly([R]-3-hydroxybutyrate) (PHB) blocks were synthesized and evaluated as possible constituents in acrylic bone cements for use in orthopaedic applications. The copolymers were produced by conventional free radical copolymerization and incorporated in one commercially available acrylic bone cement brand, Antibiotic Simplex (AKZ). Cements with formulations containing 6.7 and 13.5 wt % of PMMA-graft-PHB were prepared. The morphology of the graft copolymer particles was suggested to influence the ability of the modified cement to be processed. Formulations containing more than about 20 wt % of the graft copolymer resulted in cement doughs that, both after first preparation and several hours later, were either sandy or soft spongy in texture and, thus, would be unacceptable for use in orthopaedic applications. The morphologies of the powders and the volumetric porosity (p) and ultimate compressive strength ...
The purpose was to evaluate low-dose CT colonography without cathartic cleansing in terms of image quality, polyp visualization and patient acceptance. Sixty-one patients scheduled for colonoscopy started a low-fiber diet, lactulose and amidotrizoic-acid for fecal tagging 2 days prior to the CT scan (standard dose, 5.8-8.2 mSv). The original raw data of 51 patients were modified and reconstructed at simulated 2.3 and 0.7 mSv levels. Two observers evaluated the standard dose scan regarding image quality and polyps. A third evaluated the presence of polyps at all three mSv levels in a blinded prospective way. All observers were blinded to the reference standard: colonoscopy. At three times patients were given questionnaires relating to their experiences and preference. Image quality was sufficient in all patients, but significantly lower in the cecum, sigmoid and rectum. The two observers correctly identified respectively 10/15 (67%) and 9/15 (60%) polyps {>=}10 mm, with 5 and 8 ...
Purpose To investigate the sensitivity and accuracy of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) for restaging the mediastinum after induction chemotherapy in patients with non-small-cell lung cancer (NSCLC). Patients and Methods One hundred twenty-four consecutive patients with tissue-proven stage IIIA-N2 disease who were treated with induction chemotherapy and who had undergone mediastinal restaging by EBUS-TBNA were reviewed. On the basis of computedtomography, 58 patients were classified as having stable disease and 66 were judged to have had a partial response. All patients subsequently underwent thoracotomy with attempted curative resection and a lymph node dissection regardless of EBUS-TBNA findings. Results Persistent nodal metastases were detected by using EBUS-TBNA in 89 patients (72%). Of the 35 patients in whom no metastases were assessed by EBUS-TBNA, 28 were found to have residual stage IIIA-N2 ...
Purpose: To describe the technique of DE MDCT colonoscopy and to assess its feasibility. Materials and Methods: 8 patients were scanned with DSCT with a DE scan protocol and dose modulation software. Analysis was performed using dedicated DE software. Prone non-contrast images and DE supine images after contrast injection were obtained. Results: DE colonoscopic images were successfully obtained in 7 patients, but the FOV did not cover all colonic segments in 1 patient, thus resulting in a technical success rate was 87.5%. Streak artifacts were present in the pelvic region in 2 patients. Virtual unenhanced images and iodine map images were obtained for all patients. In 1 patient a polypoid non-enhancing structure was noted on the iodine map, and conventional colonoscopy revealed impacted stool. Enhancing rectal cancer in 1 patient was correctly shown on the iodine map. Iodine maps helped to differentiate stool fragments/retained fluid by the absence of enhancement when compared to prone ...
Regional cerebral blood flow (rCBF) was assessed with single photon emission computedtomography (SPECT), "1"2"3I-N-isopropyl-iodoamphetamine ("1"2"3I-IMP), and the Table-Look-Up method in 51 children (27 boys, 24 girls) considered neurologically normal and aged 1 month to 15 years (mean age, 4 years 1 month; standard deviation (SD) 3 years 11 months) divided into seven age groups. The rCBF was measured in cortical regions, the cerebellum, thalamus, and the head of the caudate nucleus. Curves for reference values and standard deviations were defined for each region. The rCBF rapidly increased until 2 years of age, reaching maximum values during the third to fifth periods (2 to 10 years of age) in each region. The rCBFs then decreased, reaching adult levels at 10 to 15 years of age. The rCBF reached maximum values later in the frontal region than in other regions. The rCBF during the early period increased most prominently in the occipital ...
The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computedtomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of the tangential channel is around 3.10{sup 11} n*cm{sup 2}/s. This facility will be based on a conical neutron collimator with two circular ...
The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computedtomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of the tangential channel is around 3.1011 n*cm2/s. This facility will be based on a conical neutron collimator with two circular diaphragms with ...
(1) To determine the accuracy of computedtomography (CT) in the evaluation of ligament tear and avulsion in patients with tibial plateau fracture. (2) To evaluate whether the presence or severity of fracture gap and articular depression can predict meniscal injury. A fellowship-trained musculoskeletal radiologist retrospectively reviewed knee CT and MRI examinations of 41 consecutive patients presenting to a level 1 trauma center with tibial plateau fractures. Fracture gap, articular depression, ligament tear and footprint avulsions were assessed on CT examinations. The MRI studies were examined for osseous and soft tissue injuries, including meniscal tear, meniscal displacement, ligament tear, and ligament avulsion. CT demonstrated torn ligaments with 80% sensitivity and 98% specificity. Only 2% of ligaments deemed intact on careful CT evaluation had partial or complete tears on MRI. Although the degree of fracture gap and articular ...
Ischemic bowel disease is a rare disorder whose incidence is increasing as the mean age of the population increases. Diagnosis by clinical, laboratory and radiologic means is often difficult, and delay in definitive therapy results in substantial morbidity and mortality. A series of 26 consecutive patients, with proved acute superior mesenteric ischemia, was retrospectively reviewed: the authors reports the diagnostic methods performed preoperatively, the site and the cause of infarction and the time passed between the first radiograph and surgery. Plain abdominal radiographs were performed in 25 of 26 patients, screening abdominal US in 23 cases and CT in 19 cases. All radiological examinations were retrospectively reviewed by the three authors, independently, to recognize the different signs of infarction. On plain abdominal films, the findings warranting a presumptive diagnosis of bowel infarction were air-fluid levels (84% of cases), dilated bowel loops (48%), thickened and ...
The accuracy is investigated of both lymphangiography and CT in detecting lymph nodes metastases in 59 patients evaluated preoperatively and subsequently submitted to surgery with selective/systemic pelvic and paraaortic lymphadenectomy. CT accuracy was also investigated in 46 patients with a clinically suspected relapse of ovarian cancer (verified by means of clinical and/or CT follow-up in 36 patients, by laparotomy in 7, by fine-needle biopsy in 1 and by necroscopy in the last 2). In the first group (previously untreated patients) the overall results in the pelvis were, respectively, for lymphangiography and CT: 94.9% vs 89.8% accuracy, 86.6% vs 60% sensitivity, 97.7% vs 100% specificity, and 92.8% vs 100%, 95.5% vs 88% positive and negative predictive values. In the paraaortic region the results were: 89.1% vs 86.5% accuracy, 73.3% vs 66.6% sensitivity, 100% specificity for both techniques, 100% positive predictive value, and 84.6% vs 81.5% negative predictive value. In the second ...
Aim: To investigate interpretative accuracy and reporting time for radiologists performing computedtomography (CT) colonography in day-to-day non-academic clinical practice. Materials and methods: Thirteen radiologists from seven centres, who were reporting CT colonography in non-academic daily clinical practice, interpreted a dataset of 15 colonoscopically validated cases in a controlled environment. Ten cases had either a cancer or polyp >10 mm; one case had a medium polyp and four were normal. Correct case categorization and interpretation times were compared using analysis of variance to aggregated results obtained from both experienced observers and observers recently trained using 50 cases, working in an academic environment. The effect of experience was determined using Spearman's rank correlation. Results: Individual accuracy was highly variable, range 53% (95% CI 27-79%) to 93% (95% CI 68-100%). Mean accuracy overall ...
Hepatocellular carcinoma (HCC) is characterized by tumor vascularization from the hepatic artery. The objective of our work was to compare color Doppler ultrasonography (CDU), including power Doppler ultrasonography (PDU) with radiographic imagings with contrast medium in regard to the detection of the arterial tumor vascularity of small hepatocellular carcinomas (HCC). We examined 42 small HCC lesions 2 cm or less in diameter in 37 patients for arterial tumor vascularity by conventional CDU, PDU, dynamic computedtomography (dCT), digital subtraction angiography (DSA), and CT hepatic arteriography (CTA). Color images were detected in 25 (59.5%) and 28 (66.7%) of the 42 lesions with conventional CDU and PDU, respectively, and tumor vascularity was detected in 26 (61.9%) by dCT, 23 (54.8%) by DSA, and 29 (69.0%) by CTA. Tumor vascularity could be detected in 51.9% by PDU and CTA, more than by conventional CDU, dCT, and DSA (44.4, 44.4, and ...
To illustrate frequently encountered anatomic variations on PNS computedtomography(CT) and to assess their clinical significance. CT findings of 1523 patients, who underwent PNS CT with no history of sinus surgery, were reviewed, and prevalence of each anatomic variation and its relationship with mucociliary clearance pathway was evaluated. Two categories of anatomic variations were encountered. The first group included variations of the turbinates, such as concha bullosa(28.6%), paradoxical middle turbinate(31.5%), of the uncinate process, such as medially bent or folded(36.3%), laterally bent(3.7%) or uncinate bulla(0.5%), of the ethmoidal sinus, such as Haller's cell(28.2%), large agger nasi cell(9.6%) or large ethmoidal bulla(23.5%) and nasal septal deviation(24.1%), which might cause obstruction of mucociliary clearance pathway and thus give rise to secondary obstructive sinusitis. The second group included Onodi cell(1.4%) and ...
To illustrate frequently encountered anatomic variations on PNS computedtomography(CT) and to assess their clinical significance. CT findings of 1523 patients, who underwent PNS CT with no history of sinus surgery, were reviewed, and prevalence of each anatomic variation and its relationship with mucociliary clearance pathway was evaluated. Two categories of anatomic variations were encountered. The first group included variations of the turbinates, such as concha bullosa(28.6%), paradoxical middle turbinate(31.5%), of the uncinate process, such as medially bent or folded(36.3%), laterally bent(3.7%) or uncinate bulla(0.5%), of the ethmoidal sinus, such as Haller's cell(28.2%), large agger nasi cell(9.6%) or large ethmoidal bulla(23.5%) and nasal septal deviation(24.1%), which might cause obstruction of mucociliary clearance pathway and thus give rise to secondary obstructive sinusitis. The second group included Onodi cell(1.4%) and medial ...
Mycobacterium xenopi is one of the most common agents responsible for nontubercolar mycobacterial pulmonary disease on AIDS patients. These lesions have been studied with conventional radiography while CT has been used in patients with a specific mycobacterioses or non-AIDS pulmonary conditions from Mycobacterium xenopi. 12 AIDS patients were examined. They had pulmonary lesions from Mycobacterium xenopi, patients age ranged 30 to 46 years. All patients had CD4 blood levels lower than 250 cells/mL and Mycobacterium xenopi in the sputum. All patients underwent a standard chest radiograph and a CT examination. CT images were evaluated by three radiologists independently and the definitive diagnosis was made in the presence of a fourth radiologist. Chest CT showed parenchymal consolidation in 66% of cases, associated with bilateral basal bands in 16% of cases. Consolidation was unilateral in 41% of cases and most frequently involved the right lower lobe. Bilateral reticular interstitial ...
Medical imaging using single gamma-ray-emitting radionuclides typically makes use of parallel hole collimators or pinholes in order to achieve good spatial resolution. However, a tradeoff in sensitivity is inherent in the use of a collimator, and modern preclinical single photon emission computedtomography (SPECT) systems detect a very small fraction of emitted gamma rays, often less than 0.1%. A system for small animal SPECT imaging which uses no collimators could potentially achieve very high sensitivity-several tens of percent-with reasonably sized detectors. This would allow two significant improvements in preclinical studies: images could be obtained more rapidly, allowing higher throughput for screening applications, or for dynamic processes to be observed with very good time resolution; and images could be obtained with less radioactive tracer, making possible the in vivo imaging of low-capacity receptor systems, aiding research into ...
There is significant interest in using computedtomography (CT) for in vivo imaging applications in mouse models of disease. Most commercially available mouse x-ray CT scanners utilize a charge-coupled device (CCD) detector coupled via fibre optic taper to a phosphor screen. However, there has been little research to determine if this is the optimum detector for the specific task of in vivo mouse imaging. To investigate this issue, we have evaluated four detectors, including an amorphous selenium (a-Se) detector, an amorphous silicon (a-Si) detector with a gadolinium oxysulphide (GOS) screen, a CCD with a 3:1 fibre taper and a GOS screen, and a CCD with a 2:1 fibre taper and both GOS and thallium-doped caesium iodide (CsI:Tl) screens. The detectors were evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), detective quantum efficiency (DQE), stability over multiple exposures, and noise in reconstructed CT ...
CT of the gastrointestinal tract is commonly performed after administration of a high-density diluted iodinated oral contrast material. However, because if inadequate mixing of the contrast material with the gastrointestinal contents, pseudotumor and poor mucosal visualization are frequently shown on abdominal CT. To overcome these problem, 10% corn oil emulsion (COE) is tested as an alternative oral contrast agent in 40 patients. We analyse patients tolerance, gastric mucosal visualization and discrimination of pancreas from the duodenal C-loop to 10% COE in 40 patients compared with those obtained from 35 patients, who was received high-density diluted iodinated oral contrast agent (gastrografin). The results are as follows : 1. Patients' tolerance to 10% COE is similar to that to conventional oral contrast agent. 2. Image of the gastric mucosa from patients receiving 10% COE is superior to that receiving oral contrast agent. 3. The discrimination between pancreatic head ...
CT of the gastrointestinal tract is commonly performed after administration of a high-density diluted iodinated oral contrast material. However, because if inadequate mixing of the contrast material with the gastrointestinal contents, pseudotumor and poor mucosal visualization are frequently shown on abdominal CT. To overcome these problem, 10% corn oil emulsion (COE) is tested as an alternative oral contrast agent in 40 patients. We analyse patients tolerance, gastric mucosal visualization and discrimination of pancreas from the duodenal C-loop to 10% COE in 40 patients compared with those obtained from 35 patients, who was received high-density diluted iodinated oral contrast agent (gastrografin). The results are as follows : 1. Patients' tolerance to 10% COE is similar to that to conventional oral contrast agent. 2. Image of the gastric mucosa from patients receiving 10% COE is superior to that receiving oral contrast agent. 3. The discrimination between pancreatic head from ...
By using a model dielectric matrix in electron self-energy evaluations the computational effort of a quasiparticle band-structure calculation for a semiconductor is greatly reduced. Applications to various systems with or without inversion symmetry, having narrow or wide band gaps, and semiconductor alloys demonstrate the reliability and accuracy of the method. Calculations have been performed for thirteen semiconducting or insulating materials: Si, LiCl, AlP, AlAs, AlSb, GaP, GaAs, GaSb, InP, InAs, InSb, and the Al{sub 0.5}Ga{sub 0.5}As and In{sub 0.53}Ga{sub 0.47}As alloys. Excellent agreement with experimental results is obtained for the quasiparticle energies for these materials. The only three exceptions, {ital E}({Gamma}{sub 1{ital c}}) of AlP, {ital E}({ital L}{sub 1{ital c}}) of AlAs, and {ital E}({ital L}{sub 1{ital c}}) of AlSb are discussed and attributed to various experimental uncertainties. Several other quasiparticle-excitation-related properties are ...
By using a model dielectric matrix in electron self-energy evaluations the computational effort of a quasiparticle band-structure calculation for a semiconductor is greatly reduced. Applications to various systems with or without inversion symmetry, having narrow or wide band gaps, and semiconductor alloys demonstrate the reliability and accuracy of the method. Calculations have been performed for thirteen semiconducting or insulating materials: Si, LiCl, AlP, AlAs, AlSb, GaP, GaAs, GaSb, InP, InAs, InSb, and the Al_0_._5Ga_0_._5As and In_0_._5_3Ga_0_._4_7As alloys. Excellent agreement with experimental results is obtained for the quasiparticle energies for these materials. The only three exceptions, E(#GAMMA#_1_c) of AlP, E(L_1_c) of AlAs, and E(L_1_c) of AlSb are discussed and attributed to various experimental uncertainties. Several other quasiparticle-excitation-related properties are also examined in this work. The many-body corrections to the eigenvalues of ...
The convolution/superposition algorithm for computing dose from photon beams in radiation therapy planning requires knowledge of the energy spectrum. The algorithm can compute the dose for a polyenergetic beam as the weighted sum of the individual dose contributions from monoenergetic beams. In this study we exploit interface effects apparent in the dose distributions to discriminate among spectra of high energy photon beams. We have studied the sensitivity of the depth dose distribution to the energy components using a hypothetical beam for various field sizes and depths in water and water-lung-water media. Six theoretical spectra were simulated. We compared depth dose data from these spectra using three quantitative measures which are inherently free of normalization ambiguities: for homogeneous water, the ratio D_2_0/D_1_0 and a logarithmic derivative in the buildup region LD_b_u_i_l_d_-_u_p and for inhomogeneous ...
Anti-carcinoembryonic antigen monclonal antibody (MAb) CEA 102 was produced by immunization with purified CEA and the specific accumulation of radiolabeled CEA 102 in colorectal cancers was investigated by autoradiography of sugical specimens using Fuji Computed Radiography (FCR). Five patients with colorectal cancer were injected intravenously with {sup 131}I-labeled intact CEA 102 or its F(ab'){sub 2}. Primary tumor and liver metastases were successfully detected by external scanning with a gamma camera in 4 cases. Autoradiographic study of the surgical specimens using FCR showed predominant localization of {sup 131}I-labeled CEA 102 in primary tumors and liver metastases in all cases. Even a small liver metastasis (0.5 cm) was clearly visualized in the autoradiogram by FCR. The pixel distribution curves of the density of the respective tissues in the autoradiograms by FCR showed the heterogeneity of the distribution of administreted radiolabeled MAb in ...
Anti-carcinoembryonic antigen monclonal antibody (MAb) CEA 102 was produced by immunization with purified CEA and the specific accumulation of radiolabeled CEA 102 in colorectal cancers was investigated by autoradiography of sugical specimens using Fuji Computed Radiography (FCR). Five patients with colorectal cancer were injected intravenously with "1"3"1I-labeled intact CEA 102 or its F(ab')_2. Primary tumor and liver metastases were successfully detected by external scanning with a gamma camera in 4 cases. Autoradiographic study of the surgical specimens using FCR showed predominant localization of "1"3"1I-labeled CEA 102 in primary tumors and liver metastases in all cases. Even a small liver metastasis (0.5 cm) was clearly visualized in the autoradiogram by FCR. The pixel distribution curves of the density of the respective tissues in the autoradiograms by FCR showed the heterogeneity of the distribution of administreted radiolabeled MAb in individual tumors, ...
Quantitative evaluation of CRT and CR observations in indentification of malignancy using phantom and clinical data. A breast phantom and a total of 40 patients were imaged by Fuji computed radiography (FCR). The images were interpreted twice by six radiologists both on CR film (2510 x 2000 pixels x 10 bits, 0.1 mm spatial resolution) and on a CRT monitor (1568 x 1152 pixels x 10 bits, 0.1 mm pixel size with double expansion) with image processing parameters of a toutine (RN 1.0, RE 0.2), for a calcification (RN 9.0, RE 4.0) and for a mass (RN 7.0, RE 2.0). The forty clinical cases included breast diseases with calcifications, masses, and normal breasts. Two-tailed t-test was performed to analyze interpretation of simulated microcalcifications and masses in the phantom. The receiver operating characteristic (ROC) analysis was performed to evaluate clinical cases. In all interpretation studies using both breast phantom and clinical cases, there ...
Gamma scanning measurements are used to determine the radioactive nuclides from an irradiated fuel rod in a hot cell which is a routine task in the Irradiated Materials Examination Facility (IMEF) of the Korea Atomic Energy Research Institute (KAERI), Total gamma spectra of radioactive nuclides and the atomic ratio of {sup 134}Cs to {sup 137}Cs in a few segments of a single fuel rod are measured by the present gamma scanning system. For the purpose of determining the radioactive nuclide's distribution in detail within a fuel rod quantitatively, we attempt to upgrade the present gamma scanning system in this paper, therefore, an investigation of the feasibility of the tomographic gamma scanning (TGS) technique, which is one of the promising nondestructive assay (NDA) methods is proposed. The TGS technique is an efficient method and it has an accurate precision for the characterization of several fuel parameters. In this paper, a principle and an emission ...
Jun 16, 2011 ... The research is part of a team effort to help the hardwood sawmill industry automate with computer vision systems, and computer-aided or ...
Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T{sub ...
The article explains the method of selecting the optimum energy for correcting the energy selectivity of tomographic projection and the optimum length of the crystals corresponding to it when the dual energy method in computerized tomography is used. Results of numerical calculations for actual materials and count results are presented.
In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).
In this study the development of a methodology to detect illicit drugs and plastic explosives is described with the objective of being applied in the realm of public security. For this end, non-destructive assay with neutrons was used and the technique applied was the real time neutron radiography together with computerized tomography. The system is endowed with automatic responses based upon the application of an artificial intelligence technique. In previous tests using real samples, the system proved capable of identifying 97% of the inspected materials.
Compton scatter tomography utilizes the electronic collimation characteristics available through the Compton scattering angle-energy correlation to obtain tomographic images. In this work we present particular aspects of the technique, which are relevant to the inverse radiation transport problem of reducing marginal projection data to radial two-phase flow regime maps. The results indicate a viable technique for the tomographic imaging of tow-phase flow using practical source strengths and reasonably few detectors.
In the case where sources and receivers are not distributed on a 2-D plane, seismic tomography inversion was studied. In tomography experiments, the existing wells are generally used. In such case, sources and receivers are frequently not distributed on a 2-D plane. The 2.5-D analysis method including 2-D structure and 3-D ray-tracing was thus developed. This method is featured by less memory necessary for ray-tracing calculation, and the same algorithm for velocity determination as 2-D analysis method. In previous methods, since analysis is generally carried out by projecting sources and receivers on a certain assumed 2-D plane, it can derive correct results in the case of constant velocity and straight ray, however, in the other case, it derives incorrect results. Application of 3-D tomography requires a large amount of memory, and falls into poor convergence because of various parameters. The 2.5-D analysis method can ...
Nuclear medicine and magnetic resonance imaging (MRI) are widely used in cardiac diagnostics. Both techniques have been carefully evaluated and are equivalent for the assessment of regional and global wall motion as well as the evaluation of ejection fraction and cardiac volumes, though MRI is herein currently seen as gold standard. For evaluation of myocardial perfusion, extensive data exist for nuclear imaging, that, next to high diagnostic accuracy for evaluation of coronary artery disease, show incremental prognostic information and allow for independent risk stratification. Because of rapid technical advance, myocardial perfusion imaging has also become feasible with cardiac MRI. Results of recent studies are promising, but the data are few compared to perfusion scintigraphy. For viability assessment in patients with ischemic cardiomyopathy, positron emission tomography (PET) with FDG is currently seen as gold standard. However, single photon emission ...
OBJECTIVETo assess the new quantitative bone scan parameters as markers of Charcot neuroosteoarthropathy (CNO) activity.RESEARCH DESIGN AND METHODSForty-two...Full Text Available
Emphasis was put on the comparative quantitative structure-activity approaches to the exploration of action mechanisms of structurally different classes of compounds showing the same type of activity...Full Text Available
Effective small interfering RNA (siRNA)–mediated therapeutics require the siRNA to be delivered into the cellular RNA-induced silencing complex (RISC). Quantitative information of this essential...Full Text Available
A single radial hemolysis test was developed for quantitation of specific antibody to non-hemagglutinating viruses. With the human coronaviruses as models, this test utilizes the binding properties...Full Text Available
We have exploited ``progeny testing'' to map quantitative trait loci (QTL) underlying the genetic variation of milk production in a selected dairy cattle population. A total of 1,518 sires, with progeny...Full Text Available
Gene expression data has been used in lieu of phenotype in both classical and quantitative genetic settings. These two disciplines have separate approaches to measuring and interpreting epistasis, which...Full Text Available
Deficits in prepulse inhibition (PPI) are a biological marker for schizophrenia. To unravel the mechanisms that control PPI, we performed quantitative trait loci (QTL) analysis on 1,010 F2 mice derived...Full Text Available
The Electronic REference To access In vivo Concentrations (ERETIC) method was applied to 1H HR-MAS spectroscopy. The accuracy, precision, and stability of ERETIC as a quantitative...Full Text Available
Purpose/Objective: At present, treatment verification between portal and reference images is performed based on manually-identified features by radiation oncologist, which is both time-consuming and potentially error-prone. There is a demand for the computerized verification procedure in clinical application. The purpose of this study is to develop a computerized portal verification scheme for pelvic treatment fields. Materials/Methods: The automated verification system involves image acquisition, image feature extraction, feature matching between reference and portal images and quantitative evaluation of patient setup. Electronic portal images with a matrix size of 256 x 256 and 12 bit gray levels were acquired using a liquid matrix electronic portal imaging device. Simulation images were acquired by digitizing simulation films using a TV camera into images with 256 x 256 matrix and 8 bit gray levels. Initially a Canny edge detector is applied to identify the ...
Quantum computers hold great promises for the future of computation. In this paper, this new kind of computing device is presented, together with a short survey of the status of research in this field. The principal algorithms are introduced, with an emphasis on the applications of quantum computing to physics. Experimental implementations are also briefly discussed.
The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.
Automatic segmentation of anatomical structures in medical images is a valuable tool for efficient computer-aided radiotherapy and surgery planning and an enabling technology for dynamic adaptive radiotherapy. This paper presents the design, algorithms and validation of new software for the automatic segmentation of CT images used for radiotherapy treatment planning. A coarse to fine approach is followed that consists of presegmentation, anatomic orientation and structure segmentation. No user input or a priori information about the image content is required. In presegmentation, the body outline, the bones and lung equivalent tissue are detected. Anatomic orientation recognizes the patient's position, orientation and gender and creates an elastic mapping of the slice positions to a reference scale. Structure segmentation is divided into localization, outlining and refinement, performed by procedures with implicit anatomic knowledge using standard image ...
Objective: To determine the optimal contrast injection protocol for 64-MDCT coronary angiography. Materials and methods: One hundred and fifty consecutive patients scheduled to undergo retrospectively electrocardiographically gated 64-MDCT. Each 30 patients were assigned to use a different contrast protocol: group 1: uniphasic protocol (contrast injection without saline flush); group 2: biphasic protocol (contrast injection with saline flush); group 3A, 3B and 3C: triphasic protocol (contrast media + different saline diluted contrast media + saline flush). Image quality scores and artifacts were compared and evaluated on both transaxial and three-dimensional coronary artery images among each contrast protocol. Results: Among the triphasic protocol groups, group 3A (30%:70% contrast media-saline mixture was used in second phase) used the least contrast media and had the least frequency of streak artifacts, but there were no significant differences in coronary artery attenuation, image ...
The aim of the paper is to review the role of interventional radiology in the management of hemodialysis vascular access and complications in renal transplantation. The evaluation of patients with hemodialysis vascular access is complex. It includes the radiology/ultrasound (US) evaluation of the peripheral veins of the upper extremities with venous mapping and the evaluation of the central vein prior to the access placement and radiological detection and treatment of the stenosis and thrombosis in misfunctional dialysis fistulas. Preoperative screening enables the identification of a suitable vessel to create a hemodynamically-sound dialysis fistula. Clinical and radiological detection of the hemodynamically significant stenosis or occlusion demands fistulography and endovascular treatment. Endovascular prophylactic dilatation of stenosis greater than 50% with associated clinical abnormalities such as flow-rate reduction is warranted to prolong access patency. The technical success ...
Purpose: To assess the role of CT in the evaluation of traumatic and spontaneous oesophageal perforation. Materials and methods: From March 2001 to May 2003, we studied 12 patients (7 males and 5 females; age range: 25-66 years, mean age: 43.5 years) with suspected oesophageal perforation due to motor-vehicle accidents (4 cases), stab wound (one case), post-intubation (2 cases), foreign body ingestion (2 cases) and spontaneous (3 cases). Five patients underwent standard chest and cervical radiography; two patients with suspected foreign body ingestion also underwent a gastrografin swallow study; all of the 12 patients underwent CT of the neck, chest and abdomen before and after intravenous, and in four cases oral, administration of contrast material. Results: In 5 patients with cervical, thoracic and abdominal trauma, the CT examination showed the presence of pleuroparenchymal injury (pneumothorax, pleural effusion and subcutaneous emphysema) as well as findings suggestive of ...
An important unresolved issue in outcomes analysis for lung complications is the effect of poor or completely lacking heterogeneity corrections in previously archived treatment plans. To estimate this effect, we developed a novel method based on Monte Carlo (MC) dose calculations which can be applied retrospectively to RTOG/AAPM-style archived treatment plans (ATP). We applied this method to 218 archived nonsmall cell lung cancer lung treatment plans that were originally calculated either without heterogeneity corrections or with primitive corrections. To retrospectively specify beam weights and wedges, beams were broken into Monte Carlo-generated beamlets, simulated using the VMC++ code, and mathematical optimization was used to match the archived water-based dose distributions. The derived beam weights (and any wedge effects) were then applied to Monte Carlo beamlets regenerated based on the patient computedtomography densities. Validation ...
A computedtomography (CT) cut-off for differentiating neoplastic lesions (polyps/carcinoma) from normal colon in contrast-enhanced CT colonography (CTC) relating to the contrast phase and lesion size is determined. CT values of 64 colonic lesions (27 polyps <10 mm, 13 polyps {>=}10 mm, 24 carcinomas) were determined by region-of-interest (ROI) measurements in 38 patients who underwent contrast-enhanced CTC. In addition, the height (H) of the colonic lesions was measured in CT. CT values were also measured in the aorta (A), superior mesenteric vein (V) and colonic wall. The contrast phase was defined by xA + (1 - x)V using x as a weighting factor for describing the different contrast phases ranging from the pure arterial phase (x=1) over the intermediate phases (x=0.9-0.1) to the pure venous phase (x=0). The CT values of the lesions were correlated with their height (H), the different phases (xA + (1 - x)V) and the ratio [xA + (1 ...
The purpose of this paper is to report the personal experience with helical CT evaluation of hepatocellular carcinoma treated with various percutaneous interventional procedures. From December 1996 to September 1998 it were examined with helical CT 41 patients (73 nodules in all) with hepatocellular carcinoma treated with percutaneous ablation therapies: conventional ethanol injection in 18 subjects (31 nodules), one-shot ethanol injection 3 (8 nodules), radiofrequency thermal ablation in 16 (25 nodules), and combined chemo embolization and ethanol injection in 4 (9 nodules). CT performed was 4-27 days after the last session, acquiring biphasic volumetric images in 14 patients and triphasic volumetric images in 27. A second treatment with subsequent CT study was performed for 28 lesions; 15 underwent 3 serial studies and 6 underwent 4 studies. Compared with pretreatment findings, the diameter was unchanged in 62% of the nodules and increased in 38%. Morphology was unchanged in 63% of ...
Single photon emission computedtomography (SPECT) of lung perfusions permits to map functioning lung parenchyma with higher sensitivity than CT. Delivering higher radiations doses it used to increase local control in lung carcinoma; this strategy is based on radiobiological and clinical studies. Lung parenchyma is a dose-limiting tissue in patients irradiated for lung cancer. Functional mapping based on SPECT and CT findings permits to design radiation beams such as to minimize irradiation of functioning lung. [Italian] L'integrazione delle immagini diagnostiche aventi diverso contenuto informativo anatomico-funzionale puo' essere utilizzata nella radioterapia per migliorare le procedure diagnostiche e ottimizzare la geometria dell'irraggiamento. I sistemi per l'elaborazione di piani di radioterapia oggi in uso sono direttamente interfacciati con gli apparecchi di Tomografia Computerizzata (TC) e ...
Aim: The purpose of this prospective study was to evaluate the value of immunoscintigraphy (ISG) with anti-225.28S in clinically suspected ocular melanoma. Methods: For this purpose standardized ISG was performed in 36 patients using both planar acquisition and emission computedtomography (ECT). Ocular melanoma was present in 31 patients. In 21 patients therapy was enucleation of the eye. These specimens were evaluated by histology and immunohistochemistry in 11 of 21 patients. Results: Regarding the clinical diagnosis, ISG was positive only in 15 of 31 patients with ocular melanoma, regarding histology in 11 of 21 and regarding immunohistochemistry in 5 of 6 patients with a positive immunoreaction. 5 patients showed no immunoreactivity, their ISG was negative. Conclusion: Thus a good correlation between ISG and immunohistochemistry was observed. However ISG using the cutaneous melanoma antibody 225.28S cannot be recommended for the diagnostic ...
Multi-dimensional modelling of two-phase flow requires accurate constitutive relationships for interfacial parameters such as interfacial heat transfer, void fraction distribution, interfacial area, etc. However, existing diagnostic systems for measurement of two-phase flow parameters have difficulty measuring two or three-dimensional void distributions required for determination of interfacial parameters. In this work, a Real-Time Neutron Radiography (RTNR) system is developed for non-intrusive measurement of two-phase flow parameters in nuclear fuel channels at low thermal neutron fluxes (on the order of 10{sup 6}n/cm{sup 2}-s). This advanced radiation technique has the advantage of measuring two-phase flow in 3 1/2 dimensions (x,{integral}dy,t) where the 1/2 dimension refers to an integrated or averaged space dimension. Pipe flow channels, annulus flow channels, MAPLE-type nuclear fuel flow channels, and CANDU-type nuclear fuel flow channels are investigated. Measurements of flow ...
Multi-dimensional modelling of two-phase flow requires accurate constitutive relationships for interfacial parameters such as interfacial heat transfer, void fraction distribution, interfacial area, etc. However, existing diagnostic systems for measurement of two-phase flow parameters have difficulty measuring two or three-dimensional void distributions required for determination of interfacial parameters. In this work, a Real-Time Neutron Radiography (RTNR) system is developed for non-intrusive measurement of two-phase flow parameters in nuclear fuel channels at low thermal neutron fluxes (on the order of 10"6n/cm"2-s). This advanced radiation technique has the advantage of measuring two-phase flow in 3 1/2 dimensions (x,#integral#dy,t) where the 1/2 dimension refers to an integrated or averaged space dimension. Pipe flow channels, annulus flow channels, MAPLE-type nuclear fuel flow channels, and CANDU-type nuclear fuel flow channels are investigated. Measurements of flow regime, void ...
Authors retrospectively analyzed the CT findings of mediastinal lesions in surgically or clinically confirmed 37 cases at Kosin Medical College during recent 4 years from September 1979 to August 1983. 1. Among 37 caes, malignant lymphoma were 7 cases, thymoma and vascular lesion or anomaly were 5 cases respectively, benign teratoma and tuberculous mediastinal lymphadenitis and neurogenic tumor were 4 cases respectively, pericardial cyst were 2 cases, bronchogenic cyst, non-specific cyst, pancreatic pseudocyst, mesothelioma, Bochdalek hernia was 1 case respectively. 2. The sex ratio between male and female was about 1 : 1 and the majority of the patients with malignant lymphoma and teratoma was under 20 years old. 3. CT findings of the each mediastinal lesion. 1) Primary mediastinal malignant lymphoma. (1) A large, matted, continuous and midline-crossing mass was observed in the superior and the anterior mediastinums in all cases. (2) In 3 cases, irregular lower densities were seen in ...
Aim: To evaluate the role of computedtomography (CT) in needle placement for ganglion impar blocks, and to determine the efficacy of CT-guided ganglion impar blocks in the management of coccydynia. Materials and methods: The results of ganglion impar blockade in eight patients with coccydynia secondary to trauma or unknown cause were reviewed. The diagnosis of coccydynia was based on clinical history, location of pain, and response to previous diagnostic and therapeutic procedures. The eight patients were treated with CT-guided ganglion impar blocks to manage their coccyx pain after conservative procedures, including oral medication and cushions, failed to provide relief. All patients were subjected to ganglion impar blocks under a thin-section CT-guided technique for needle placement, using a mixture of bupivacaine and triamcinolone. The patients were followed-up for a period of 6-months. Results: Eight patients were treated in this study ...
In this article is reviewed the role of ComputedTomography (CT) in thoracic complications following ortho topic liver transplantation (OLT). In a post-OLT population of 567 patients transplanted in the Italian institutions, 100 patients (17.6%) were examined with chest CT. It was reviewed data relative to the total number of examinations, clinical and/or radiographic indications, the CT technique-i.e., conventional (with (out) intravenous, i.v., contrast material) or high-resolution (HRCT). It also reviewed the radiologic patterns and their correlation with the other clinical, bronchoscopic and/or laboratory results. Of 152 chest CT examinations, 45 (29.6%) were performed because of clinical indications, 31 (20.4%) because of a radiographic abnormality, 64 (42.1%) because of clinical and radiographic abnormality, 64 (42.1%) because of clinical and radiographic indications, while in 12 cases (7.9%) the reasons were unknown; 133/152 (87.5%) ...
The purpose of this study was to test a large sample of different coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in 64-slice multidetector-row computedtomography (MDCT) in vitro and to provide a catalogue of currently used coronary artery stents when imaged with state-of the-art MDCT. We examined 68 different coronary artery stents (57 stainless steel, four cobalt-chromium, one cobalt-alloy, two nitinol, four tantalum) in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70). Stents were imaged in axial orientation with standard parameters: 32x0.6 collimation, pitch 0.24, 680 mAs, 120 kV, rotation time 0.37 s. Four different image reconstructions were obtained with varying convolution kernels and section thicknesses: (1) soft, 0.6 mm, (2) soft, 0.75, (3) medium soft, 0.6, and (4) stent-optimized ...
The objective of this study was to determine the prevalence of concha bullosa and nasal septal deviation and their potential relationships to maxillary sinusitis. 883 CT scans taken at Creighton University...Full Text Available
Advances in laboratory animal imaging have provided new resources for noninvasive biomedical research. Among these technologies is microcomputed tomography (microCT) which is widely used to obtain high...Full Text Available
With regard to the elastic wave exploration, discussions have been given on the relationship between frequency and resolution in P-wave velocity tomography using the initial travel time. The discussions were carried out by using a new analysis method which incorporates the concept of Fresnel volume into tomography analysis. The following two arrangements were used in the calculation: a cross hole arrangement, in which seismic source and vibration receiving points were arranged so as to surround the three directions of a region extending 250 m in the horizontal direction and 500 m in the vertical direction, and observation is performed between two wells, and a permeation VSP arrangement in which the seismic source is installed on the ground surface and receiving points installed in wells. Restructuring was performed on the velocity structure by using a total of 819 observation travel times. This method has derived results of the restructuring ...
BackgroundNew technology allows more precise definition of structural alterations of all retinal layers although it has not been used previously in cases of optic...Full Text Available
PurposeTo determine the effects of age on global and sectoral peripapillary retinal nerve fiber layer (RNFL), macular thicknesses and optic nerve head (ONH) parameters...Full Text Available
PurposeTo establish normative values for macular light sensitivity and to determine the intrasession fluctuation of perimetric responses using the OPKO/OTI microperimeter.Full Text Available
The comprehensive survey explains the indications and the specific value of the modern tomographic modalities with respect to the various diagnostic issues. Numerous reproductions of CT, MRI, US scans illustrate the aspects discussed. (orig./CB)
BackgroundIn vitro data suggest that changes in myocardial substrate metabolism may contribute to impaired myocardial function in diabetic cardiomyopathy (DCM)....Full Text Available
Eddy current testing (ECT) method is widely used as the non-destructive evaluation (NDE) of the various kinds of material degradation occurring in nuclear power plants (NPPs) components including steam generator (SG) tubes. Detection of any defects or flaws in the steam generator tubes in the early stage is very important in maintenance of NPP for its primary role as the pressure boundary with thin wall thickness. Although the ECT technique provides lots of information for a SG management, it has a generic problem in its reliability due to a low ability in detect of small defects and some difficulty in a signal analysis. For the improvement of these shortcomings in conventional ECT, profile-MRPC (motorized rotating pancake coil) ECT technology was developed in KAERI. The key of this new technology is the development of new eddy current probes, designated as a diagnostic probe (D-probe). The D-probe is furnished with a simultaneous dual function of a defect detection and shape changes ...
Eddy current testing (ECT) method is widely used as the non-destructive evaluation (NDE) of the various kinds of material degradation occurring in nuclear power plants (NPPs) components including steam generator (SG) tubes. Detection of any defects or flaws in the steam generator tubes in the early stage is very important in maintenance of NPP for its primary role as the pressure boundary with thin wall thickness. Although the ECT technique provides lots of information for a SG management, it has a generic problem in its reliability due to a low ability in detect of small defects and some difficulty in a signal analysis. For the improvement of these shortcomings in conventional ECT, profile-MRPC (motorized rotating pancake coil) ECT technology was developed in KAERI. The key of this new technology is the development of new eddy current probes, designated as a diagnostic probe (D-probe). The D-probe is furnished with a simultaneous dual function of a defect detection and shape changes ...
Temperature and concentration profiles of CO in a laminar, axisymmetric, premixed methane-air Bunsen flame are measured using line-of-sight diode laser absorption spectroscopy and computer tomographic (CT) reconstruction. Absorption spectra for P(20) (v=2<-1) and P(27) (v=1<-0) vibrotational transitions of CO were measured at 21 evenly spaced positions over a 1.33 cm span for a 1.3 cm radius flame. CT reconstruction algorithm was based on Fourier convolution. The tomographically reconstructed normalized transmission profiles derived from absorption spectra, in conjunction with a quantum mechanical model for vibrotational behavior of CO, yielded both temperature and concentration profiles. The Bunsen flame had 3 distinct zones: an inner rich-premixed flame zone, an outer non-premixed flame zone and an unburnt core region. The reconstructed temperature profile showed that the core region temperature was close to ambient and rapidly increased to adiabatic flame ...
The patients studied were referred for routine abscess localization with indium-111 labelled autologous leukocytes. One series (n=15) was studied at 1 day after reinjection of labelled cells and a second series (n=9) was studied between 4 hours and 4 days after reinjection of labelled cells. The leukocytes were isolated by a gravity sedimentation method and labelled with In-111 oxinate according to Roevekamp and co-workers. The labelled cell suspension administered to the patient contained between 11 and 15 MegaBq (300-400 microCi). The indium-111 concentration in the liver and spleen was quantitated using a scintillation camera and an on-line computer system. Phantom studies were carried out to obtain conversion factors from geometric mean counts to MegaBq of activity for both liver and spleen. Once determined, the amount of activity in liver and spleen was corrected for physical decay of In-111 and expressed as a percentage of the ...
A three-dimensional, three-phase, multiple-component numerical simulator was developed to investigate transport and growth of microorganisms in porous media and the impacts of microbial activities on oil recovery. The microbial activities modeled in this study included: (1) growth, retention, chemotaxis, and end product inhibition of growth, (2) the formation of metabolic products, and (3) the consumption of nutrients. Major mechanisms for microbial enhanced oil recovery (MEOR) processes were modeled as follows: (1) improvement in sweep efficiency of a displacement process due to in situ plugging of highly-permeable production zones by cell mass or due to improved mobility control achieved by increasing the viscosity of the displacing fluid with a biopolymer, and (2) solubilization and mobilization of residual oil in porous media due to the reduction of the interfacial tension between oleic and aqueous phases by the production of a biosurfactant. The numerical solutions for ...
This work presents a study of the {sup 1}P{sup 0} excited states of He that can be reached by absorption of a single photon carrying an energy close to the double ionization threshold (DIT) (79 eV). Above the DIT, these states are the double continuum states; below, they are the double excited states. These two types of states are tightly coupled to the single continuum states with or without excitation of the residual ion He{sup +}, owing to their degeneracy in energy. In a one-photon process, these states can only be formed owing to the electronic correlations in the system which must be well described to obtain quantitative good results. Our study is a part of the work which aims at a united description of all these doubly excited, ionized-excited, and double continuum states. We use the Hyperspherical R-Matrix with Semiclassical Outgoing Waves (HRM-SOW) method, initially dedicated to double photoionization studies. We extend it to extract information on the ...
Thallium-201 myocardial imaging was performed in 80 children with coronary arterial lesions due to Kawasaki disease in order to assess the value of serial and exercise myocardial imagings. In eight of these children, abnormalities of the image were noted. Twenty children had serial thallium studies with an interval of three to 18 months, and five of these showed changes in the image including appearance of a new perfusion defect in one patient and improvement of perfusion defects in four. These changes of the myocardial image were correlated well with coronary angiographic findings obtained within a few days of the isotope studies. It was noted that the changes of the myocardial image were more frequently observed at relatively recent period recovered from Kawasaki disease. Exercise myocardial imaging using a bicycle ergometer was performed in eight children with coronary arterial lesions. In three an evidence of improvement of the myocardial perfusion was noted immediately after ...
This paper deals with the heat transfer characteristics of horizontal steam generators, particularly under natural circulation (decay heat removal) conditions on the primary side. Special emphasis is on the inherent features of horizontal steam generator behaviour. A mathematical model of the horizontal steam generator primary side is developed and qualitative results are obtained analytically. A computer code, called HSG, is developed to solve the model numerically, and its predictions are compared with experimental data. The code is employed to obtain for VVER 440 steam generators quantitative results concerning the dependence of primary-to-secondary heat transfer efficiency on the primary side flow rate, temperature and secondary level. It turns out that the depletion of the secondary inventory leads to an inherent limitation of the decay energy removal in VVER steam generators. The limitation arises as a consequence of the steam generator ...
Accurate prediction of ribbed duct flow and heat transfer is of importance to the gas turbine industry. The present study comprehensively validates the use of large eddy simulations (LES) for predicting flow and heat transfer with measured flowfield data in a stationary duct with 90"o ribs and elucidates on the detailed physics encountered in the developing flow region, the fully developed region, and the 180"o bend region. Among the major flow features predicted with accuracy are flow transition at the entrance of the duct; the distribution of mean and turbulent quantities in the developing, fully developed, and 180"o bend; the development of secondary flows in the duct cross-section and the 180"o bend; and friction and heat transfer augmentation. At the duct inlet, both the computations and experiments show that the peak turbulence intensities reach values as high as 40% in the streamwise and spanwise directions and 32% in the vertical direction, and a comparison ...
Recent advances in self-amplified spontaneous emission (SASE) experiments stimulate interest in quantitative comparison of measurements with theory. In this paper we show that the widely used simulation code TDA3D, developed by Tran and Wurtele [Comput. Phys. Commun. 54, 263 (1989)] even though a single frequency code, can be used to determine the output power in the SASE process with excellent approximation in the exponential growth regime. The method applies when the gain is not very high, which is a special advantage, because when the gain is not very high, the analytical calculation is particularly difficult since the exponential growing term does not dominate. The analysis utilizes a scaling relation between the output power and the number of simulation particles in the code TDA3D: left-angle P right-angle=N_#lambda#"'/N_#lambda# left-angle P"'right-angle, where left-angle P right-angle is the output power and N_#lambda# is the line ...
Quantum computing is a quickly growing research field. This article introduces the basic concepts of quantum computing, recent developments in quantum searching, and decoherence in a possible quantum...Full Text Available
We present interactive computer programs for the analysis of nucleic acid sequences. In order to handle these programs, minimum computer experience is sufficient. The nucleotide sequence of the human...Full Text Available
USGS geologists Peter Triezenberg and William Danforth sit with WHOI/LDEO Computer Technician Tom Bolmer in the Healy computer lab. This was during a scientific expedition to map the Arctic seafloor....
Twenty-seven patients with symptoms or clinical findings suggesting joint or bone disorders of the anterior chest wall (ACW) were evaluated by spiral CT with 3-dimensional (3-D) and multiplanar reconstructions. Preceding conventional ACW tomography was performed in 10 patients. ACW joint and bone changes were visualized more adequately by coronal 2-D reconstructions based on spiral CT than by conventional tomography. In addition, nonossified costal cartilages and soft tissue lesions were demonstrated. 3-D reconstructions sometimes added information, especially in patients with fracture and dislocation. (orig.).
Objectives: To investigate optical coherence tomography consistency on foveal thickness, foveal volume, and macular volume measurements in patients with and without diffuse diabetic macular edema. Introduction: Optical coherence tomography represents an objective technique that provides cross-sectional tomographs of retinal structure in vivo. However, it is expected that poor fixation ability, as seen in diabetic macular edema, could alter its results. Several authors have discussed the reproducibility of optical coherence tomography, but only a few have addressed the topic with respect to diabetic maculopathy. Methods: The study recruited diabetic patients without clinically evident retinopathy (control group) and with diffuse macular edema (case group). Only one eye of each patient was evaluated. Five consecutive fast macular scans were taken using Ocular Coherence Tomography 3; the 6 mm macular map ...
A new model for computations is considered which combines the quantum computer with the chaotic dynamics amplifier, based on the logistic map. We discuss the satisfiability problem and argue that the problem can, in principle, be solved in polynomial time if one uses the new model for computations.
One of the central questions of molecular biology is the discovery of the semantics of DNA. This discovery relies in a critical way on a variety of expensive computations. In order to solve these computations, both parallel computers and special-purpose hardware play a major role.
Computer And Network Security: Information For Everyone: This presentation was originally prepared as the 14th talk in a series known as "The Programmer's ...
AFFF has fabricated the (U, Pu)O_2 mixed oxide fuels for PHWRs, BWRs, PFBRs and FBTRs. The quantitative dissolution of the fuel samples are required within time for accurate determination of uranium-plutonium in chemical quality control laboratory. This paper describes the use of microwave heating technique in quantitative dissolution of (U, Pu)O_2 MOX (from 0.4% to 44% PuO_2). (author)
... These assumptions are quantitatively investigated by calculating tie icldti\\e inportance of ... A modified lon-shore current model is used to study the ...
BackgroundDiscrepancies between the conclusions of different meta-analyses (quantitative syntheses of systematic reviews) are often ascribed to methodological differences. The objective...Full Text Available
Motivation: Automatic recognition of cell identities is critical for quantitative measurement, targeting and manipulation of cells of model animals at single-cell resolution. It has been...Full Text Available
Typing Workshop": [Introductions] [Intro, DNA Basics, and Historical Perspective] [DNA Extraction] [Validation and QA/QC] [DNA Quantitation] [PCR Amplification] [STR Loci and Kits]...
BACKGROUND: An approach to the study of the pharmacokinetics of drugs in the lung is to measure their concentrations in bronchial biopsy specimens. The main criticism of this technique is that bronchial...Full Text Available
This laboratory exercise demonstrates some basic principles in parasitology by using experimental studies of the relationship of Hymenolepis diminuta with its rodent host.
Abstract: The current financial crisis has now led most major central banks to rely on quantitative easing. The unique Japanese experience of quantitative easing is the only experience which enables us to judge this therapy's effectiveness and the timing of the exit strategy. In this paper, we provide a new empirical framework to examine the effectiveness of Japanese monetary policy during the ''lost'' decade and quantify the effect of quantitative easing on Japan's activity and prices. We combine advantages of Markov-switching VAR methodology with those of factor analysis to establish two major findings. First, we show that the decisive change in regime occurred in two steps: it crept out from late 1995 and established itself durably in February 1999. Second, we show for the first time th...
... and high-quality photospheric-phase Type II SN spectra to constrain core- collapse SN explosions, massive star evolution, and distances in the Universe ...
OBJECTIVEEvaluate the qualitative and quantitative differences between moderated and unmoderated on-line social support groups focused on asthma.DESIGNA...Full Text Available
AIM: To investigate the effects of gallbladder stones on motor functions of the gallbladder and the dynamics of bile flow in asymptomatic gallstone disease.METHODS: Quantitative hepatobiliary...Full Text Available
OBJECTIVE AND DESIGNThis study used qualitative and quantitative methods to examine the reasons primary care physicians and nurses offered for their inability to initiate guideline-concordant...Full Text Available
The concentration of apolipoproteins was measured by quantitative immunoelectrophoresis in rat serum, in the lipoprotein-free ultracentrifugal fraction (density greater than 1.21) of serum, and in renal...Full Text Available
In this model, without dark matter, the flat rotation curves of galaxies and the mass-to-light ratios of clusters of galaxies are described quantitatively. The hypothesis is that the agent of gravitational...Full Text Available
The Computation Directorate at Lawrence Livermore National Laboratory has four major areas of work: (1) Programmatic Support -- Programs are areas which receive funding to develop solutions to problems or advance basic science in their areas (Stockpile Stewardship, Homeland Security, the Human Genome project). Computer scientists are 'matrixed' to these programs to provide computer science support. (2) Livermore Computer Center (LCC) -- Development, support and advanced planning for the large, massively parallel computers, networks and storage facilities used throughout the laboratory. (3) Research -- Computer scientists research advanced solutions for programmatic work and for external contracts and research new HPC hardware solutions. (4) Infrastructure -- Support for thousands of desktop computers and numerous LANs, ...
As the jump from 2D to 3D, seismic exploration lives a new revolution with the use of converted PS waves. Indeed PS converted waves are proving their potential as a tool for imaging through gas; lithology discrimination; structural confirmation; and more. Nevertheless, processing converted shear data and in particular determining accurate P and S velocity models for depth imaging of these data is still a challenging problem, especially when the subsurface is anisotropic. To solve this velocity model determination problem we propose to use reflection travel time tomography. In a first step, we derive a new approximation of the exact phase velocity equation of the SV wave in anisotropic (TI) media. This new approximation is valid for non-weak anisotropy and is mathematically simpler to handle than the exact equation. Then, starting from an isotropic reflection tomography tool developed at Lt-'P, we extend the isotropic bending ray ...
The staging of patients with multiple myeloma demands sensitive imaging methods for the assessment of the skeletal system. MRI allows for direct visualization of the bone marrow which exhibits five different infiltration patterns in multiple myeloma: 1. normal appearance of the bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. ''salt and pepper'' pattern with inhomogeneous bone marrow signals due to multiple fat islands. The combination of T1w-SE and STIR sequences is best suited for detecting all infiltration patterns and for the differential diagnoses e. g. hemangiomas. With parallel imaging in MRI, acquisition times can be markedly reduced and whole-body screening of the bone marrow can be achieved within 30 min. MRI is superior to radiography for the detection of focal as well as diffuse infiltration. Multidetector computedtomography ...
CT and MRI of acquired abnormalities of the inner ear and cerebello-pontine angle present themselves with very typical findings. The imaging should be adapted to the pathology looked for and either CT or MRI should be used alone or in combination.CT, especially high resolution CT (HRCT), provides an excellent bone contrast, while MRI has a much superior soft tissue contrast. Acute inflammatory changes of the inner ear are solely depicted by contrast-enhanced MRI. HRCT excellently depicts osseous changes of the inner ear and cerebellopontine angle such as chronic ossifying labyrinthitis occurring after acute labyrinthitis, otosclerotic or traumatic changes. Tumorous changes not yielding to bony changes are best delineated by MRI. Posttraumatic hemorrhage and chronic fibrotic changes within the labyrinth are depicted by MRI, only. In conclusion HRCT and MRI are excellent methods to delineate acquired abnormalities of the inner ear and cerebello-pontine angle. HRCT best depicts osseous ...
Environmental computer science is a new partial discipline of applied computer science, which makes use of methods and techniques of information processing in environmental protection. Thanks to the inter-disciplinary nature of environmental problems, computer science acts as a mediator between numerous disciplines and institutions in this sector. The handbook reflects the broad spectrum of state-of-the art environmental computer science. The following important subjects are dealt with: Environmental databases and information systems, environmental monitoring, modelling and simulation, visualization of environmental data and knowledge-based systems in the environmental sector. (orig.).
We characterized the absorption and short-term translocation of cadmium (Cd) in rice (Oryza sativa ‘Nipponbare’) quantitatively using serial images observed with a positron-emitting...Full Text Available
Gas chromatography-selected ion monitoring-mass spectral analysis using [13C6]indole-3-acetic acid (IAA) as an internal standard provides an effective means for quantitation of...Full Text Available
A quantitative description is proposed for the depletion-induced slip thickness and velocity profile of a polymer solution near the wall-fluid interface in simple shear flow. The inhomogeneous polymer density profile at a flat wall is inserted into the equations of motion for the flow of a polymer solution near the flat wall. The theory is in quantitative agreement with simulation results. (letter to the editor)
An (Awassi × Merino) × Merino backcross family of 172 ewes was used to map quantitative trait loci (QTL) for different milk production traits on a framework map of 200 loci across all...Full Text Available