Motivation: Cell tracking is an important method to quantitatively analyze time-lapse microscopy data. While numerous methods and tools exist for tracking cells in 2D time-lapse images,...Full Text Available
In situ X-Ray microtomography offers new opportunities for analysing sintering mechanisms since it allows 3D observation of the microstructural evolution of the powder all along a sintering cycle. With synchrotron radiation at ESRF, a 3Dimage with a resolution of 2 {mu}m can be obtained in about one minute. In addition to the visual examination of the images, relevant microstructural parameters can be measured through quantitativeimage analysis using recently developed tools. In this paper the results obtained with two materials, loose copper powder and compacted steel powder, are resumed. For copper powder, the dispersion of local parameters such as particle co-ordination number and porosity is investigated. Concerning steel compacts, data about pore morphology evolution and on local strains provides clues for ...
... stenosis. It looks from the transesophageal and the 3-D echo that most of the problem is really ... posterior leaflet, which you can see on the 3-D echo image is a major source. The anterior ...
The purpose of this study was to use high-resolution magnetic resonance (MR) imaging combined with image analysis to investigate the three-dimensional (3D) trabecular structure, anisotropy, and connectivity of human vertebral, femoral, and calcaneal specimens. The goal was to determine whether: (a) MR-derived measures depict known skeletal-site-specific differences in architecture and orientation of trabeculae; (b) 3D architectural parameters combined with bone mineral density (BMD) improve the prediction of the elastic modulus using a fabric tensor formulation; (c) MR-derived 3D architectural parameters combined with BMD improve the prediction of strength using a multiple regression model, and whether these results corresponded to the results obtained using higher resolution depictions of trabecular architecture. A ...
BackgroundMany three-dimensional (3D) images are routinely collected in biomedical research and a number of digital atlases with associated anatomical and other information have...Full Text Available
The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y...Full Text Available
The application of 3D rotational angiography marks a breakthrough in endovascular treatment of aneurysmas of the brain. 3Dimages are produced based on image series obtained by rotational angiography, so that the anatomic details of interest can be visualized from any requested angle. (orig./CB)
A three-dimensional (3-D) prestack reverse-time migration algorithm for common-source P-wave data from anisotropic media is developed and illustrated by application to synthetic data. Both extrapolation of the data and computation of the excitation-time imaging condition are implemented using a second-order finite-difference solution of the 3-D anisotropic scalar-wave equation. Poorly focused, distorted images are obtained if data from anisotropic media are migrated using isotropic extrapolation; well focused, clear images are obtained using anisotropic extrapolation. A priori estimation of the 3-D anisotropic velocity distribution is required. Zones of anomalous, directionally dependent reflectivity associated with anisotropic fracture zones are detectable in both the ...
... catheter ablation for paroxysmal atrial fibrillation procedure utilizing 3-D mapping and rotational intracardiac echocardiography. This program is ... of the MRI scan and then there's the 3-Dimage, which is generated from the pixels chosen ...
ObjectiveCompare occlusal contacts calculated from 3D virtual models created from clinical records to contacts identified clinically using shimstock and transillumination.Full Text Available
In many radiotherapy clinics, geometric uncertainties in the delivery of 3D conformal radiation therapy and intensity modulated radiation therapy of the prostate are reduced by aligning the...Full Text Available
Our goal is to determine an optimized image-guided setup by comparing setup errors determined by two-dimensional (2D) and three-dimensional (3D) image guidance for head and neck cancer (HNC)...Full Text Available
The authors have been developing a 3D brain CT image display system for planning of craniofacial operations. This system helps doctors plan craniofacial operations on a graphic display (GD) terminal by rendering 3Dimages reconstructed from a set of slices. The authors reveal how the system generates 3D shapes of organs from given CT images and how it modifies or transforms the obtained shapes according to the user's request. The system functions now available are extraction and display of the skull and the skin, measurement of the distance between two points on the skull given through the GD terminal, and generating and eliminating a polygonal region arbitrarily given on the skull as an operative region. (Auth.).
The aim of this study was to qualitatively and quantitatively study MR artifacts of various stents on the basis of in vitro experiments. We were particularly interested whether sequence type and orientation of the stent with respect to the static magnetic field influences the artifact. We examined 18 stents of different material (nitinol, stainless steel, cobalt alloy), different design of the stent meshes (AccuLink, OmniLink, DynaLink, Xact, Protoge, Wallstent Monorail), different diameter (5-10 mm) and different length (18-58 mm) with a turbo spin echo (TSE), a 2D-fast low angle shot (FLASH) and a 3D-FLASH sequence. The MR images were examined qualitatively with respect to possible artifacts. Furthermore we examined the MR data quantitatively: The contrast-noise-ratio (CNR) was determined both within the stent and outside (within the tube); based on these values we calculated the ...
Summary Solid state nuclear track detectors are used to determine the concentration of a particles in the environment. The standard method for assessing exposed detectors involves 2D image analysis. However 3Dimaging has the potential to provide additional information relating to angle as well as to differentiate clustered hit sequences and possibly energy of a particles but this could be time consuming. Here we describe a new method for rapid high-resolution 3Dimaging of solid state nuclear track detectors. A `LEXT' OLS3100 confocal laser scanning microscope (Olympus Corporation, Tokyo, Japan) was used in confocal mode to successfully obtain 3Dimage data on four CR-39 plastic detectors. Three-dimensional visualization and image analysis enabled ...
I discuss several examples of critical phenomena in O(N) models where topological excitations play an important role at criticality. I focus particular attention on the O(2) model in 3D, where recent measurements of the vortex string length distribution in equilibrium suggest the existence of a quantitative picture of the critical behavior in terms of defects. The compatibility of this perspective with renormalization group predictions is examined.
Purpose Video-assisted thoracic surgery (VATS) has recently been adopted for complicated anatomical lung resections. During these thoracoscopic procedures, surgeons view the operative field on a two-dimensional (2-D) video monitor and cannot palpate the organ directly, thus frequently encountering anatomical difficulties. This study aimed to estimate the usefulness of preoperative three-dimensional (3-D) imaging of thoracic organs. Methods We compared the preoperative 64-row three-dimensional multidetector computed tomography (3DMDCT) findings of lung cancer-affected thoracic organs to the operative findings. Results In comparison to the operative findings, the branches of pulmonary arteries, veins, and bronchi were well defined in the 3D-MDCT images of 27 patients. Conclusion 3D-MDCT imag...
Detailed three dimensional wing kinematics and aerodynamic characteristics are experimentally presented for the free flight of a beetle, Allomyrina dichotoma, which has a pair of elytra (fore wings) and hind wings. The kinematic parameters of the wing motion, such as the wing tip trajectory, angle of attack, torsion angle, and camber deformation, are obtained from a 3D reconstruction technique that involves the use of two or three synchronized high-speed cameras to digitize various points marked on the wings. Our data show outstanding characteristics of wing deformation and flexibility in the free flight of the beetle. To find out the mechanism of aerodynamic force, the leading edge vortex (LEV) and trailing edge vortex (TEV) on both elytron and hind wing were observed by using smoke wire visualization and digital particle image velocimetry (DPIV) technique. Qualitative smoke lines in the region of the most intent vortex ...
Computed tomography allows today to reconstruct three-dimensional (eD) images fram axial scans. The authors report their experience in cranio-facial pathology achived in two Departments of Radiology (University of Trieste, Italy and University of Standford, California). 3Dimages have been realized using two different softwares, one of which allows to reconstruct both soft tissue and bone structures. The application in maxillo-facial traumas, cranio-facial malformations and head tumours are disscussed. 3Dimages turned out to be very useful for the optimal visualization and for the spatial demostration of the lesion and have potential applications in cranio-facial surgery and radiotherapy.
Quantitative microscopy has been extensively used in biomedical research and has provided significant insights into structure and dynamics at the cell and tissue level. The entire procedure...Full Text Available
Most algorithms for three-dimensional (3D) reconstruction from electron micrographs assume that images correspond to projections of the 3D structure. This approximation limits the attainable resolution of the reconstruction when the dimensions of the structure exceed the depth of field of the microscope. We have developed two methods to calculate a reconstruction that corrects for the depth of field. Either method applied to synthetic data representing a large virus yields a higher resolution reconstruction than a method lacking this correction.
Purpose of this work is to investigate the role of Helical CT and the usefulness of three-dimensional (3D) imaging for pre-operative planning and follow-up of reconstructive maxillofacial surgery with alloplastic material in neoplastic disease involving this region. From 1996 to 1999 eleven patients were examined with Helical CT and 3Dimages for planning of maxillofacial plastic and reconstructive surgery for advanced cancer of this anatomically complex region. A 3D-modulated titanium mesh (100%) or micro nets was used to rebuild the anterior surface of maxillary bone and the orbital floor. The mesh was cut to the appropriate size and shape and curved where necessary. Within the residual sinusal cavity a siliconed filling was used surmounting an acrylic prosthesis with dental arch to rebuild the palate. A rehydrated ...
Development of a number of original 3-D migration methods and algorithms is described. The computational efficiency of these algorithms is demonstrated by implementing them on vector and parallel supercomputers. Two-dimensional post-stack and pre-stack depth migration algorithms in the frequency - space domain using implicit finite difference method were also developed and implemented on a parallel computer, and adapted for applications that range from deep crustal imaging of seismic wavefields that involve wide ranging travel times and frequencies. All implicit finite difference migration algorithms were highly prallelized . The one pass 3-D post-stack depth migration algorithm was extensively used for imaging of seismic monitoring data from Cold Lake, Alberta. Experience shows that it provides the right trade-off between accuracy and computational efficiency. ...
Faults are being actively investigated across Japan since the Great Hanshin-Awaji Earthquake. Discussed in this report is the application of the 3D near-surface reflection seismic survey in big cities. Data from trenching and drilling is used for the geological interpretation of the surroundings of a fault, and the reflection seismic survey is used to identify the position, etc., of the fault. In this article, when the results obtained from the experimental field are examined, it is found that the conventional 2D imaging reflection survey betrays the limit of its capability when the geological structure is complicated, that the 3D reflection seismic survey, on the contrary, is capable of high-precision imaging and, when augmented by drilling, etc., becomes capable of a more detailed interpretation, and that it also contributes effectively to the improvement of ...
The quantitativeimaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.
Three dimensional data of brain from the formalin-fixed fetuses were collected without isolation, by the 4.7 tesla super high magnetic field MRI and the developmental process of the cerebral parenchyma was studied by 3Dimages. Subjects were 13 fetal brain and MRI was performed using 3D-steady-state free precession sequence. The isolated brain is very soft and fragile and is deformed by its weight at the imaging. However 3D-MRI can be obtained without isolation, and the deformation is remarkably small. The subependymal germinal matrix layer did not be observed in 7 weeks-old fetus, appeared at 9 weeks-old and increased gradually. Then it rapidly reduced from 28 weeks-old. The volume calculated, from 3D-MRI, increased rapidly from 9 weeks-old to 23 weeks-old, and reached the ...
Subtractive imaging in confocal fluorescence light microscopy is based on the subtraction of a suitably weighted widefield image from a confocal image. An approximation to a widefield image can be obtained by detection with an opened confocal pinhole. The subtraction of images enhances the resolution in-plane as well as along the optic axis. Due to the linearity of the approach, the effect of subtractive imaging in Fourier-space corresponds to a reduction of low spatial frequency contributions leading to a relative enhancement of the high frequencies. Along the direction of the optic axis this also results in an improved sectioning. Image processing can achieve a similar effect. However, a 3D volume dataset must be acquired and processed, yielding a result essentially identical to subtractive ...
We develop a 3-D model to simulate the synthetic aperture radar (SAR) image formation process of an undulated vegetation canopy such as corn grown in fields with large periodic drainage reliefs. We explain how the simulated SAR image of undulated vegetation medium is obtained by the convolution of a 2-D slice of the 3-D simulated SAR system point spread function [(PSF), emulating the SAR beam modeled by a cosine modulated Gaussian], with the 2-D projection of the observed undulated vegetation canopy (modeled with scatterers randomly distributed in 3-D undulated space) followed by the extraction of each look envelope, the summation of looks, and sampling in azimuthal and range directions. Our model is useful to study the parameters involved in the formation and the analysis of SAR images of undulated ...
Computation of effective flow properties of fluids in porous media based on three dimensional (3D) pore structure information has become more successful in the last few years, due to both improvements in the input data and the network models. Computed X-ray microtomography has been successful in 3D pore imaging at micron scale, which is adequate for many sandstones. For other rocks of economic interest, such as chalk and diatomite, submicron resolution is needed in order to resolve the 3D-pore structure. To achieve submicron resolution, a new method of sample serial sectioning and imaging using Focused Ion Beam (FIB) technology has been developed and 3D pore images of the pore system for diatomite and chalk have been obtained. FIB was used in the milling of ...
To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using ...
The aim of this study is three folds: to compare the eight-channel phased-array and standard circularly polarized (CP) head coils in visualiazation of the intracranial vessels, to compare the three-dimentional (3D) time-of-flight (TOF) MR angiography (MRA) techniques, and to define the effects of parallel imaging in 3D TOF MRA. Fifteen healthy volunteers underwent 3D TOF MRA of the intracranial vessels using eight-channel phased-array and CP standard head coils. The following MRA techniques were obtained on each volunteer: (1) conventional 3D TOF MRA with magnetization transfer; (2) 3D TOF MRA with water excitation for background suppression; and (3) low-dose (0.5 ml) gadolinium-enhanced 3D TOF MRA with water ...
The objective of this study was to develop a method for 3D subtraction CT angiography and to optimize the visualization after semiautomatic segmentation. Ten patients with aneurysms of the abdominal aorta were examined using spiral CT. To reconstruct the vessels, as well as adjacent organs such as the liver and kidneys, one image data volume was acquired before and after injection of the contrast agent. The CT scans were obtained with a Siemens Somatom Plus 4. To improve the results of automatic segmentation, as well as visualization by maximum intensity projection (i.e. removal of bony structures), subtraction of both image volumes is necessary. However, small translation shifts disturb the subtraction process and produce artificial contours. To calculate the disparities along the three coordinate axes of two corresponding image volumes, a cepstrum filter is applied to a pair of ...
Automatic segmentation of anatomical structures in medical images is a valuable tool for efficient computer-aided radiotherapy and surgery planning and an enabling technology for dynamic adaptive radiotherapy. This paper presents the design, algorithms and validation of new software for the automatic segmentation of CT images used for radiotherapy treatment planning. A coarse to fine approach is followed that consists of presegmentation, anatomic orientation and structure segmentation. No user input or a priori information about the image content is required. In presegmentation, the body outline, the bones and lung equivalent tissue are detected. Anatomic orientation recognizes the patient's position, orientation and gender and creates an elastic mapping of the slice positions to a reference scale. Structure segmentation is divided into localization, outlining and refinement, performed by procedures with implicit ...
Already, MR Imaging is superior in diagnostic imaging of joints in many cases; however, there have been recent developments, which are the subjects of this paper. With gradient-echo sequences acquired in 3D technique, it is possible to produce high-resolution images of joints in acceptable scantime, because gradient-echo sequences are less time-consuming than convential SE sequences. With the acquisition of two echoes, phase difference between water and fat protons have to be considered. 3DImaging is capable of displaying complex pathology in a superior way, which should be useful in preoperative planning. Tissue contrast is altered by fat saturation or magnetization transfer in order to achieve better conspicuity of lesions. Although diagnostic value of some of these options is not yet clear and further clinical ...
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...
A new three-dimensional (3D) acoustic modelling method was developed using a first-order hyperbolic wave system which was solved with explicit finite dfferences. The numerical solution of the 3D wave system provides a useful method for simulating evolution of a pressure field corresponding to compressional type waves. Existing two-dimensional (2D) elastic modelling algorithms were modified and fine-tuned for computationally efficient and realistic wave propagation simulations in complex structures. An original formulation of the 3D reverse time migration method was developed which is very accurate, does not suffer from unwanted evenescent energy, can image dips beyond 90{degree}, and does not generate multiple energy. Two case studies were performed that involved steam stimulation projects in the Cold Lake deposit. Simulations were performed ...
Objective: To determine the reproductibility of three-dimensional volume and thickness measurements of the knee joint cartilage with MRI in volunteers. Methods: The knees of 7 healthy individuals (ages 23 to 58 yrs.) were sagitally imaged with a resolution of 2x0.31x0.31 mm{sup 3}, using a fat-suppressed FLASH-3D sequence. The knee was repositioned in between replicate acquisitions, 6 data sets being obtained in each case. After semiautomatic segmentation and three-dimensional reconstruction of the cartilage, the thickness was determined independent of the original section orientation. The coefficient of variation for repeated volume measurements and the deviations of the maximal cartilage thickness values were calculated subsequently. Results: The mean variation of the cartilage volumes of the replicate measurements was 1.4% ({+-}0.8%) in the patella, 1.7% ({+-}1.5%) in the femur, 3.0% ({+-}1.2%) in the medial tibial ...
An algorithm for creating synthetic telescope images of Smoothed Particle Hydrodynamics (SPH) density fields is presented, which utilises the adaptive nature of the SPH formalism in full. The imaging process uses Monte Carlo Radiative Transfer (MCRT) methods to model the scattering and absorption of photon packets in the density field, which then exit the system and are captured on a pixelated image plane, creating a 2D image (or a 3D datacube, if the photons are also binned by their wavelength). The algorithm is implemented on the density field directly: no gridding of the field is required, allowing the density field to be described to an identical level of accuracy as the simulations that generated it. Some applications of the method to star and planet formation simulations are presented to illustrate the advantages of this new technique, and suggestions as ...
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm{sup -3} or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the ...
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm"-"3 or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design ...
We characterized the absorption and short-term translocation of cadmium (Cd) in rice (Oryza sativa ‘Nipponbare’) quantitatively using serial images observed with a positron-emitting...Full Text Available
A novel phantom has been developed to measure the modulation transfer function (MTF) in 3D for x-ray computed tomography. The phantom consists of three tungsten wires, positioned nearly orthogonal to each other. Simultaneous measurements of the MTF are taken at various locations along the three orthogonal reconstructed planes. Our computed mammotomography (CmT) system uses a Varian Paxscan 2520 digital x-ray detector which can be positioned anywhere in ~2pi steradian band and can have arbitrary trajectories. With a half-cone beam geometry and with the phantom positioned near the center of rotation, projection images are acquired over 360 degrees. Various 3D orbits are evaluated including vertical axis of rotation and saddle. Reconstructions were performed using an iterative ordered-subsets transmission algorithm on rebinned projection images, using various ...
We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.
To more accurately measure fluorescent signals from microarrays, we calibrated our acquisition and analysis systems by using groundtruth samples comprised of known quantities of red and green gene-specific DNA probes hybridized to cDNA targets. We imaged the slides with a full-field, white light CCD imager and analyzed them with our custom analysis software. Here we compare, for multiple genes, results obtained with and without preprocessing (alignment, color crosstalk compensation, dark field subtraction, and integration time). We also evaluate the accuracy of various image processing and analysis techniques (background subtraction, segmentation, quantitation and normalization). This methodology calibrates and validates our system for accurate quantitative measurement of microarrays. Specifically, we show that preprocessing the images produces results ...
Currently, x-ray mammography is the method of choice in breast cancer screening programmes. As the mammography technology moves from 2D imaging modalities to 3D, conventional computational phantoms do not have sufficient detail to support the studies of these advanced imaging systems. Studies of these 3Dimaging systems call for a realistic and sophisticated computational model of the breast. DeBRa (Detailed Breast model for Radiological studies) is the most advanced, detailed, 3D computational model of the breast developed recently for breast imaging studies. A DeBRa phantom can be constructed to model a compressed breast, as in film/screen, digital mammography and digital breast tomosynthesis studies, or a non-compressed breast as in positron emission mammography and breast CT ...
Energy-filtered X-ray photoemission electron microscopy (EXPEEM) is a microscopy technique which has the potential to provide surface chemical mapping during surface chemical processes on the nanometer scale. We studied the possibilities of EXPEEM using a Wien filter type energy analyzer in the high energy X-ray region above 1000 eV. We have successfully observed the EXPEEM images of Au islands on a Ta sheet using Au 3d_5_/_2 and Ta 3d_5_/_2 photoelectron peaks which were excited by 2380 eV X-rays emitted from an undulator (BL2A) at Photon Factory. Our recent efforts to improve the sensitivity of the Wien filter energy analyzer will also be discussed.
We present a fully automated method for three-dimensional (3D) elemental analysis demonstrated using a ceramic sample of chemistry (Ca)MgTiO_x. The specimen is serially sectioned by a focused ion beam (FIB) microscope, and energy-dispersive X-ray spectrometry (EDXS) is used for elemental analysis of each cross-section created. A 3D elemental model is reconstructed from the stack of two-dimensional (2D) data. This work concentrates on issues arising from process automation, the large sample volume of approximately 17x17x10 #mu#m"3, and the insulating nature of the specimen. A new routine for post-acquisition data correction of different drift effects is demonstrated. Furthermore, it is shown that EDXS data may be erroneous for specimens containing voids, and that back-scattered electron images have to be used to correct for these errors.
Purpose To evaluate the methods of applicator reconstruction in 3D MR-based planning for brachytherapy of cervical cancer, and to investigate applicator shifts and changes in DVH parameters during PDR treatment. Methods For each application MR scans with applicator in situ were made: three T2-weighted (4.5mm slices) Turbo Spin Echo (TSE) scans and a balanced Steady State Free Precession scan (1.5mm). Three observers tested two applicator reconstruction methods: (A) directly on the bSSFP scan and (B) on a resampled combination of the three T2-weighted scans. For 10 patients MR imaging was repeated on the second day of each PDR fraction to determine applicator shifts and changes in DVH parameters. Results For both applicator reconstruction methods the interobserver variation for the DVH para...
Quantitative digital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitativeimage data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial ...
Purpose: The aim of this study was to evaluate the accuracy of MRI in the measurement of cartilage thickness of the ankle joint in comparison to pathologic and histologic specimens. Patients and methods: The ankle joints of four fresh cadaver feet were imaged on a 1.5 T MR-unit in the coronal plane. Standard T{sub 1}-weighted spin echo (SE) and a T{sub 1}-weighted 3D-GE (FLASH-3D) sequence with fat saturation were applied. Following MR imaging, the talus was explanted and cut parallel to the MR images for macroscopic evaluation and histologic specimens were prepared. MRI measurements of the cartilage thickness of the talus were carried out in two ways: Without and with consideration of a transition zone of intermediate signal intensity between hyperintense cartilage and hypointense cortical bone. The data were compared with the anatomic ...
Introduction: The goal of this study was to compare contrast-enhanced T1-weighted Flash and Turbo-Flash sequences with conventional spin-echo sequences as a basis for planning high-precision radiotherapy. Methods: A total of 25 consecutive patients with different intracranial tumors and a disrupted blood-brain barrier were studied. T1-weighted Flash, Turbo-Flash and conventional spin-echo images were evaluated after controlled 30-s infusion of 0.1 mmol/kg body weight of Gd-DTPA. The evaluation of the three sequences included the measurement of the signal- and contrast-to-noise ratios, the visual inspection of the tumors and artifacts, and the measurement of tumor size. Results: The signal- and contrast-to-noise ratios were significantly (P<0.05-0.01) lower for Flash and Turbo-Flash than for conventional spin-echo sequences. However, visual inspection of the contrast-enhancing tumors revealed in 23 and 24 of 25 lesions of Flash and Turbo-Flash ...
Purpose: `Exoscopic` and endoscopic identification of colorectal pathologies via MRI. Methods: 5 patients (36-88 years), two normal and three with different colorectal pathologies (diverticular disease, polyps and carcinoma of the colon), were examined by MRI after colonoscopy. Subsequent to filling of the colon with a gadolinium-water mixture under MRI-monitoring, 3D-data sets of the colon were acquired in prone and supine positions over a 28 sec breathold interval. Subsequently multiplanar T{sub 1}-weighted 2D-sequences were acquired before and following i.v. administration of Gd-DTPA (0.1 mmol/kg BW). All imaging was performed in the coronal orientation. The 3D-data were interactively analysed based on various displays: Maximum intensity projection (MIP), surface shadowed display (SSD), multiplanar reconstruction (MPR), virtual colonoscopy (VC). Results: All of the colorectal ...
This contribution provides an overview and imparts basic knowledge on pertinent technical developments in magnetic resonance imaging (MRI) of the liver: 3D sequences, respiratory triggering, parallel imaging, and 3 Tesla (3T). 3D sequences can be used as T1-weighted (T1w) sequences for analyzing dynamics of contrast enhancement or as T2w sequences for MR cholangiography. Consistent improvements in respiratory triggering make it possible to obtain good image quality on T2w scans even in patients unable to hold their breath. Parallel imaging as a universal technique to accelerate image acquisition is particularly appropriate for MRI of the liver, and it has been shown that the reduced acquisition time is not achieved at the expense of image quality. Further progress in MRI of the ...
Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be the methods of choice. Pronounced MR ...
We investigated the efficacy of combined FDG-PET/CT imaging for the diagnosis of small-size uveal melanomas and the feasibility of combining separate, high-resolution (HR) FDG-PET with MRI for its improved localization and detection. Patients, methods: 3 patients with small-size uveal melanomas (0.2-1.5 ml) were imaged on a combined whole-body PET/CT, a HR brain-PET, and a 1.5 T MRI. Static, contrast-enhanced FDG-PET/CT imaging was performed of head and torso with CT contrast enhancement. HR PET imaging was performed in dynamic mode 0-180 min post-injection of FDG. MRI imaging was performed using a high-resolution small-loop-coil placed over the eye in question with T2-3D-TSE and T1-3D-SE with 18 ml Gd-contrast. Patients had their eyes shaded during the scans. Lesion visibility on high-resolution ...
The purpose of this study was to investigate the feasibility of a simple deformable phantom as a QA tool for testing and validation of deformable image registration algorithms. A diagnostic thoracic imaging phantom with a deformable foam insert was used in this study. Small plastic markers were distributed through the foam to create a lattice with a measurable deformation as the ground truth data for all comparisons. The foam was compressed in the superior-inferior direction using a one-dimensional drive stage pushing a flat 'diaphragm' to create deformations similar to those from inhale and exhale states. Images were acquired at different compressions of the foam and the location of every marker was manually identified on each image volume to establish a known deformation field with a known accuracy. The markers were removed digitally from corresponding images prior to ...
Purpose: Understanding the kinetics of tumor growth∕shrinkage represents a critical step in quantitative assessment of therapeutics and realization of adaptive radiation therapy....Full Text Available
Experimental and imaging studies in monkeys have outlined various long association fiber bundles within the temporoparietal region. In the present study the trajectory of the middle longitudinal fascicle...Full Text Available
Quantitative metallography is often used to confirm the proper processing of aerospace metallic materials. A microstructural feature of great importance for titanium alloys processed in the alpha-beta phase field is the volume fraction of primary alpha. S...
Activatable or “smart” magnetic resonance contrast agents have relaxivities that depend on environmental factors such as pH or enzymatic activity, but the MR signal depends on...Full Text Available
The vertical profiles of disc galaxies are built by the material trapped around stable periodic orbits, which form their "skeletons". According to this, the knowledge of the stability of the main families of periodic orbits in appropriate 3D models, can predict possible morphologies for edge-on disc galaxies. In a pilot survey we compare the orbital structures which lead to the appearance of "peanuts" and "X"-like features with the edge-on profiles of three disc galaxies (IC 2531, NGC 4013 and UGC 2048). The subtraction from the images of a model representing the axisymmetric component of the galaxies reveals the contribution of the non-axisymmetric terms. We find a direct correspondence between the orbital profiles of 3D bars in models and the observed main morphological features of the residuals. We also apply a simple unsharp masking technique in order to study the sharpest ...
Conformal radiation therapy represents a considerable and attractive challenge in oncology. Its aim is mainly to improve local control by increasing the dose with an acceptable rate of complications. This work overviews the world literature on this subject. The technical and theoretical requirements are highlighted. These requirements include a precise definition of the target volume by digital imaging (essentially CT scan), but also clear view of the target volume and the organs at risk, a specific collimation of the beam, 3-D dose calculations, optimization procedures, and a rigid immobilization of the patient with verification of his position. Moreover, the clinical applications of conformal radiation therapy are reviewed and discussed. (authors). 80 refs., 1 tab.
During the past three years the program has undergone a substantial revitalization. There has been no significant change in the scientific direction of this grant, in which emphasis continues to be placed on developing new or improved methods of obtaining quantitative data from radiotracer imaging studies. However, considerable scientific progress has been made in the three areas of interest: Radiochemistry, Quantitative Methodologies, and Experimental Methods and Feasibility Studies, resulting in a sharper focus of perspective and improved integration of the overall scientific effort. Changes in Faculty and staff, including development of new collaborations, have contributed to this, as has acquisition of additional and new equipment and renovations and expansion of the core facilities. 121 refs., 30 figs., 2 tabs.
The NIS-6 group at Los Alamos National Laboratory pioneered the development of Tomographic Gamma Scanning and continue to improve its utility in real measurement situations. Building on this experience we report the development of a state of the art TGS system suitable for industrial applications. The image reconstruction and visualization software has been integrated into the familiar Canberra NDA2000 software suite which also handles all other aspects of the data acquisition and management. In this paper we describe the salient design and performance parameters of the system. The application of gamma-ray tomography to safeguards for improved assay accuracy and knowledge confirmation is discussed. In particular we compare and contrast the relative merits of this TGS and a traditional Segmented Gamma Scanner and illustrate how the 3-D visualization of the TGS image can provide valuable additional ...
Level set method based segmentation provides an efficient tool for topological and geometrical shape handling. Conventional level set surfaces are only $C^0$ continuous since the level set evolution involves linear interpolation to compute derivatives. Bajaj et al. present a higher order method to evaluate level set surfaces that are $C^2$ continuous, but are slow due to high computational burden. In this paper, we provide a higher order GPU based solver for fast and efficient segmentation of large volumetric images. We also extend the higher order method to multi-domain segmentation. Our streaming solver is efficient in memory usage.
A new methodology for three-dimensional (3-D) numerical modeling of the continuous steel casting process is presented and evaluated. The results are compared with available experimental data obtained in a water-oil mold model for various flow rates and immersion depths of the submerged entry nozzle. The water-oil interface pattern at the top of the mold is also investigated. Wave formation and evolution in time is simulated with a volume tracking method. The predicted flow field inside the mold exhibits quite satisfactory agreement with the corresponding measurements, whereas some quantitative differences are observed referring to the final wave amplitude at low casting speeds. Conclusions of scientific and engineering importance concerning both the computer algorithm and the mold performance are also drawn.
The final report for a Laboratory Directed Research and Development project entitled, ``Capturing Recrystallization of Metals in a Multiscale Materials Model'' is presented. In this project, deformation and recrystallization processes have been followed experimentally and theoretically in order to incorporate essential mechanisms from the defect (dislocation) and grain size length scales. A nonlinear rotational gradient theory has been developed which enables the incorporation of microstructural parameters. The evolution of these parameters during deformation and recrystallization has been characterized qualitatively and quantitatively, applying various electron optic techniques ranging over several length scales. The theoretical and experimental framework developed is general. It has been exemplified by an application to recrystallization in single crystals and bicrystals of aluminum. The recrystallization process has been modeled using a ...
Objective: To investigate the value ofMSCT in observing the direct findings of hilar cholangiocarcinoma1Methods Multislice helical CT studies were performed on the upper abdomen in 19 consecutive patientswith painless jaundice1 Precontrast and dynamic contrast enhanced (25 s phase and 60 s phase) scanswere conducted, and 3D imageswere reconstructed using enhanced raw data in 15 cases1 The direct CT findings of hilar cholangiocarcinoma were studied by three radiologists respectively in a 32scale strategy1 The morphological features and extension of bile duct involvement by hilar cholangiocarcinoma were analyzed1 All the 19 caseswere pathologically p roved as hilar cholangiocarcinoma by surgery (15 cases) and ERCP ( 4 cases) 1 Results The direct findings and extension of hilar cholangiocarcinoma could be demonstrated in 14 out of 15 3D reconstruction images, 8 out of 19 in 25 s phase, ...
Detailed quantitative sequence stratigraphic analysis and three-dimensional (3-D) modeling of the fluvio-deltaic Pikeville, Hyden, and four Corners formations of the Breathitt Group, eastern Kentucky, indicate that it is possible to make confident deterministic correlations of sand bodies at offshore development well spacings. The key to high-confidence correlation is the delineation of the 3-D architecture of third-order composite sequences, which are seismically mappable, and the recognition of internal fourth-order sequences, which are stacked into lowstand, transgressive, and highstand sequence sets. Volumetric partitioning of reservoir sand bodies between systems tracts and sequences allows prediction of channel sandstone geometries and channel: crevasse splay ratios. Furthermore, channel-fill type is predictable from the sequence stratigraphy. Within 13 studied fourth-order ...
Recent advances in self-amplified spontaneous emission (SASE) experiments stimulate interest in quantitative comparison of measurements with theory. In this paper we show that the widely used simulation code TDA3D, developed by Tran and Wurtele [Comput. Phys. Commun. 54, 263 (1989)] even though a single frequency code, can be used to determine the output power in the SASE process with excellent approximation in the exponential growth regime. The method applies when the gain is not very high, which is a special advantage, because when the gain is not very high, the analytical calculation is particularly difficult since the exponential growing term does not dominate. The analysis utilizes a scaling relation between the output power and the number of simulation particles in the code TDA3D: left-angle P right-angle=N_#lambda#"'/N_#lambda# left-angle P"'right-angle, where left-angle P ...
Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two ...
Several neutron radiography systems designed to view transient processes on a real-time basis have been developed. With the advent of these different real-time systems comes the necessity to develop a means to quantitatively evaluate and compare these systems. A suitable method for measuring the resolution capabilities of the image-forming system is the determination of the modulation transfer function (MTF). The MTF is a measure of an imaging system's ability to reproduce the spatial frequencies present in an image. The system in use at the University of Missouri Research Reactor is described. (Auth.).
The auroras on Jupiter and Saturn can be studied with a high sensitivity and resolution by the Hubble Space Telescope (HST) ultraviolet (UV) and far-ultraviolet (FUV) Space Telescope spectrograph (STIS) and Advanced Camera for Surveys (ACS) instruments. We present results of automatic detection and segmentation of Jupiter's auroral emissions as observed by HST ACS instrument with VOronoi Image SEgmentation (VOISE). VOISE is a dynamic algorithm for partitioning the underlying pixel grid of an image into regions according to a prescribed homogeneity criterion. The algorithm consists of an iterative procedure that dynamically constructs a tessellation of the image plane based on a Voronoi Diagram, until the intensity of the underlying image within each region is classified as homogeneous. The computed tessellations allow the extraction of quantitative information about the auroral ...
This report describes the results made in fulfillment of contract DE-FG26-02NT15451, ''Multicomponent Seismic Analysis and Calibration to Improve Recovery from Algal Mounds: Application to the Roadrunner/Towaoc Area of the Paradox Basin, Ute Mountain Ute Reservation, Colorado''. Optimizing development of highly heterogeneous reservoirs where porosity and permeability vary in unpredictable ways due to facies variations can be challenging. An important example of this is in the algal mounds of the Lower and Upper Ismay reservoirs of the Paradox Basin in Utah and Colorado. It is nearly impossible to develop a forward predictive model to delineate regions of better reservoir development, and so enhanced recovery processes must be selected and designed based upon data that can quantitatively or qualitatively distinguish regions of good or bad reservoir permeability and porosity between existing well control. Recent advances in seismic ...
The 3-dimensional (3D) extension C5G7 MOX benchmark problems were solved by CHAPLET-3D code which is based on the idea of dynamic linkage of the multi-plane method of characteristics solutions. The benchmark results are quite accurate in comparison with the reference solutions, independently of the axial solver incorporated in the CHAPLET-3D code. (author)
Thallium-201 myocardial imaging was performed in 80 children with coronary arterial lesions due to Kawasaki disease in order to assess the value of serial and exercise myocardial imagings. In eight of these children, abnormalities of the image were noted. Twenty children had serial thallium studies with an interval of three to 18 months, and five of these showed changes in the image including appearance of a new perfusion defect in one patient and improvement of perfusion defects in four. These changes of the myocardial image were correlated well with coronary angiographic findings obtained within a few days of the isotope studies. It was noted that the changes of the myocardial image were more frequently observed at relatively recent period recovered from Kawasaki disease. Exercise myocardial imaging using a bicycle ergometer was performed ...
Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitativeimage quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were ...
Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitativeimage quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel ...
Neutron radiography (NR) is a useful non-destructive method for determination of hydrogen content in various building and technical materials. Monitoring of transport processes of moisture and hydrogenous liquids in porous building materials is enabled by fast, quasi-real-time NR methods based on novel imaging plate neutron detectors (IP-NDs). Hydrogen content in the samples is determined by quantitative analysis of measured profiles of neutron attenuation in the samples. Detailed description of quantitative NR method is presented by the authors in another accompanying contribution at this conference. Deterioration of building materials is originated by different processes that all require presence of water therefore it is essential to limit or prevent the transport of water through the porous material. In this presentation, results of a study of clay brick impregnation by silicone based hydrophobic agents will be ...
An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.
An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.
... see and electrophysiological study and catheter ablation with 3D mapping. During the procedure, doctors look at the ... perform a electrophysiology study with ablation, using our 3D mapping system. Keep in mind, that during the ...
The need for noninvasive sensitive techniques for the diagnosis and follow-up of metabolic bone disease in dialysis patients has stimulated the author's interest in the efficacy of more detailed quantitative bone scintigraphy. Using hemodialysis to reduce elevated soft-tissue activity at scintigraphy, an attempt was made to assess the diagnostic sensitivity of quantitative bone scintigraphy as compared to qualitative bone scintigraphic, biochemical, radiographic and bone histologic studies. The second aim of these studies was to determine if one of the two major components of renal osteodystrophy is a major determinant for skeletal radiotracer uptake. The clinical observations on the efficacy and possible specificity of quantitative bone scintigraphy in the diagnosis and follow-up during treatment of renal osteodystrophy are presented briefly in this chapter. Thus, the use of scintigraphy for the routine detection and ...
Described is the diagnosis for the cancer extension of cholangiocarcinoma by various imaging techniques and processes to support the current surgical procedure based on preoperative biliary drainage. The cancer tends to locally extend horizontally and/or vertically and its diagnosis is important for surgical indication. For the indication, multi-detector raw CT (MDCT) and MR cholangio-pancreatography (MRCP) are useful and particularly, the former can give multi-phase (arterial, portal and delayed) images to reconstruct multiplanar (MPR) and CT angiographic 3Dimages, which have made the previous invasive examinations like angiography and percutaneous transportal contrasting unnecessary. MDCT and MRCP can almost complete the diagnosis of the extension. The operative procedure is decided dependently on the site of the lesion, and of which diagnosis, whether it is hepatic hilar/on ...
Purpose: Three-dimensional rotational angiography (3DRA) is a new technique based on a rotational angiographic acquisition able to display arterial vessels in a 3D rendering mode. The system was mainly developed for neuroradiological evaluations but preliminary extracranial experiences have also been reported. The aim of our work was to compare the results of three-dimensional angiography of the carotid arteries done with high-flow injection of contrast medium from the aortic arch with the results of selective angiography. Materials and methods: Twenty patients underwent digital angiography of the supra-aortic vessels in order to quantify a stenosis of the carotid bifurcations previously detected at Doppler Ultrasound. Examinations were performed with the Philips Integris Allura system provided with the rotational angiography (RA) tool connected to a workstation for three-dimensional reconstruction able to display vessels in a ...
Background and purpose: stereotactic radiosurgery (SRS) and also fractionated stereotactic radiotherapy (SRT) offer high local control (LC) rates (> 90%). This study aimed to evaluate three-dimensional (3-D) tumor volume (TV) shrinkage and to assess quality of life (QoL) after SRS/SRT. Patients and methods: from 1999 to 2005, 35/74 patients were treated with SRS, and 39/74 with SRT. Median age was 60 years. Treatment was delivered by a linear accelerator. Median single dose was 13 Gy (SRS) or 54 Gy (SRT). Patients were followed up ? 12 months after SRS/SRT. LC and toxicity were evaluated by clinical examinations and magnetic resonance imaging. 3-D TV shrinkage was evaluated with the planning system. QoL was assessed using the questionnaire Short Form-36. Results: Median follow-up was 50/36 months (SRS/SRT). Actuarial 5-year freedom from progression/overall survival was 88.1%/100% ...
Objectives Clinical PET/MR requires the use of patient positioning aids to immobilize and support patients for the duration of the combined examination. Ancillary immobilization devices contribute to overall attenuation of the PET signal, but are not detected with conventional MR sequences and, hence, are ignored in standard MR-based attenuation correction (MR-AC). We report on the quantitative effect of not accounting for the attenuation of patient positioning aids in combined PET/MR imaging. Methods We used phantom and patient data acquired with positioning aids on a PET/CT scanner (Biograph 16, HI-REZ) to mimic PET/MR imaging conditions. Reference CT-based attenuation maps were generated from measured (original) CT transmission images (origCT-AC). We also created MR-like attenuation map...
Noninvasive prediction of vertebral body strength under compressive loading condition is a valuable tool for the assessment of clinical fractures. This paper presents an effective specimen-specific approach for noninvasive prediction of human vertebral strength using a nonlinear finite element (FE) model and an image based parameter based on the quantitative computed tomography (QCT). Nine thoracolumbar vertebrae excised from three cadavers with an average age of 42 years old were used as the samples. The samples were scanned using the QCT. Then, a segmentation technique was performed on each QCT sectional image. The segmented images were then converted into three-dimensional FE models for linear and nonlinear analyses. A new material model was implemented in our nonlinear model being more...
Free form fabrication and high resolution imaging techniques enable the creation of biomimetic tissue engineering scaffolds. A 3D CAD model of canine trabecular bone was produced via micro CT and exported to a fused deposition modeler, to produce polybutylene terephthalate (PBT) trabeculated scaffolds and four other scaffold groups of varying pore structures. The five scaffold groups were divided into subgroups (n=6) and compression tested at two load rates (49?N/s and 294?N/s). Two groups were soaked in a 25??C saline solution for 7?days before compression testing. Micro CT was used to compare porosity, connectivity density, and trabecular separation of each scaffold type to a canine trabecular bone sample. At 49?N/s the dry trabecular scaffolds had a compressive stiffness of 4.94?1.19?MP...
This paper describes a new time-resolved three-dimensional, three-component (3D-3C) measurement technique called wall-PIV. It was developed to assess near wall flow fields and shear rates near non-planar surfaces. The method is based on light absorption according to Beer-Lambert's law. The fluid containing a molecular dye and seeded with buoyant particles is illuminated by a monochromatic, diffuse light. Due to the dye, the depth of view is limited to the near wall layer. The three-dimensional particle positions can be reconstructed by the intensities of the particle's projection on an image sensor. The flow estimation is performed by a new algorithm, based on learned particle trajectories. Possible sources of measurement errors related to the wall-PIV technique are analyzed. The accuracy analysis was based on single particle experiments and a three-dimensional artificial data set simulating a rotating ...
In this work, we address the problem of road interpretation for driver assistance based on an early cognitive vision system. The structure of a road and the relevant traf?c are interpreted in terms of ego-motion estimation of the car, independently moving objects on the road, lane markers and large scale maps of the road. We make use of temporal and spatial disambiguation mechanisms to increase the reliability of visually extracted 2D and 3D information. This information is then used to interpret the layout of the road by using lane markers that are detected via Bayesian reasoning. We also estimate the ego-motion of the car which is used to create large scale maps of the road and also to detect independently moving objects. Sample results for the presented algorithms are shown on a stereo image sequence, that has been collected from a structured road.
A new direction for the national laboratories is to assist US business with research and development, primarily through cooperative research and development agreements (CRADAs). Technology transfer to the private sector has been very successful as over 200 CRADAs are in place at Sandia. Because of these cooperative efforts, technology has evolved into some new areas not commonly associated with the former mission of the national laboratories. An example of this is the analysis of fabric structures. Explicit analyses and expertise in constructing parachutes led to the development of a next generation automobile airbag; which led to the construction, testing, and analysis of the Jet Propulsion Laboratory Mars Environmental Survey Lander; and finally led to the development of CAD based custom garment designs using 3D scanned images of the human body. The structural analysis of these fabric structures is described as well as a ...
The purpose of this study was to compare 2 adaptive radiotherapy strategies with helical tomotherapy. A patient having mesothelioma with mediastinal nodes was treated using helical tomotherapy with pretreatment megavoltage CT (MVCT) imaging. Gross tumor volumes (GTVs) were outlined on every MVCT study. Two alternatives for adapting the treatment were investigated: (1) keeping the prescribed dose to the targets while reducing the dose to the OARs and (2) escalating the target dose while maintaining the original level of healthy tissue sparing. Intensity modulated radiotherapy (step-and-shoot IMRT) and 3D conformal radiotherapy (3DCRT) plans for the patient were generated and compared. The primary lesion and nodal mass regressed by 16.2% and 32.5%, respectively. Adapted GTVs and reduced plan...
In order to reduce the number of surface mining accidents related to low visibility conditions and blind spots of trucks and to provide 3D information for truck drivers and real time monitored truck information for the remote dispatcher, a 3D assisted driving system (3D-ADS) based on the GPS, mesh-wireless networks and the Google-Earth engine as the graphic interface and mine-mapping server, was developed at Virginia Tech. The research results indicate that this 3D-ADS system has the potential to increase reliability and reduce uncertainty in open pit mining operations by customizing the local 3D digital mining map, constructing 3D truck models, tracking vehicles in real time using a 3D interface ...
Brain development during the first year of life was assessed quantitatively using apparent diffusion coefficient (ADC) images constructed from diffusion-weighted MR image data. The imaging plane was coronal at the section of the pons. The cerebral peduncle, internal capsule, corona radiata, superior longitudinal fasciculus and thalamus were selected for evaluation of their ADC values. A diffusion sensitive gradient was added in the anteroposterior direction. Thus the orientation of nerve fibers in the cerebral peduncle, internal capsule and corona radiata was perpendicular to it, and that in the superior longitudinal fasciculus was parallel to it. In neonates, the cerebral peduncle and internal capsule, having been moderately myelinated at birth, showed the slowest diffusion. The corona radiata and superior longitudinal fasciculus, having been unmyelinated at birth, showed the fastest diffusion. The ...
By characterising the microstructure, quantitativeimage analysis allows to draw conclusions on the mechanical properties of materials. On fine microstructures with low contrast, e.g. of hardened steels, texture analysis has to be applied for quantification. Feeding texture parameters according to Haralick into a trained neural network, a correlation between the microstructure and the hardness of the steels C45 and 100Cr6 can be achieved. (orig.)
Purpose. To validate a protocol for creating virtual models to be used in the construction of solid prototypes useful for the planning-simulation of maxillo-facial surgery, in particular for very complex anatomical and pathologic problems. To optimize communications between the radiology, engineering and surgical laboratories. Methods and materials. We studied 16 patients with different clinical problems of the maxillo-facial district. Exams were performed with multidetector computed tomography (MDCT) and single slice computed tomography (SDCT) with axial scans and collimation of 0.5-2 mm, and reconstruction interval of 1 mm. Subsequently we performed 2D multiplanar reconstructions and 3D volume-rendering reconstructions. We exported the DICOM images to the engineering laboratory, to recognize and isolate the bony structures by software. With these data the solid prototypes were generated using stereolitography. To date, ...
The main objective of this dissertation is to build a numerical 3D geological model of a turbidite reservoir using well and seismic data. For the, the first step was to elaborate a depositional model using a high-resolution genetic stratigraphy approach. Simultaneously, the stratigraphic inversion over the seismic data resulted in an optimal acoustic impedance model. Both models, were used to build, by geostatistical methods, a 3-D geological model, which represents the spatial distribution of the reservoir facies. The studied case is the late Cretaceous Namorado turbidite system in the Campos basin, which is the reservoir of the Namorado oil field, located 80 km from the Brazilian coast, under a bathymetry between 110 and 250 m. The reservoir is a turbidite succession with 90 to 180 m thickness. It is composed by sand-supported conglomerates, matrix-supported conglomerate, massive sandstones, shales, ...
A central problem in diagnostic radiology is to compare a new X-ray picture with a previous picture and from this comparison be able to decide if anatomical changes have occurred in the patient or not. It is of primary interest that these pictures are identical in projection. If not it is difficult to decide with confidence if differences between the pictures are due to anatomical changes or differences in their projection geometry. In this thesis we present a non invasive method that makes it possible to find the relative changes in the projection geometry between the exposure of a previous picture and a new picture. The method presented is based on the projection slice theorem (central section theorem). Instead of an elaborate search for a single new picture a pre-planned set of pictures are exposed from a circular orbit above the patient. By using 3D Fourier transform techniques we are able to synthesize a new X-ray picture from this set of ...
Pinta is a system for segmentation and visualization of anatomical structures obtained from serial sections reconstructed from magnetic resonance imaging. The system approaches the segmentation problem by assigning each volumetric region to an anatomical structure. This is accomplished by satisfying constraints at the pixel level, slice level, and volumetric level. Each slice is represented by an attributed graph, where nodes correspond to regions and links correspond to the relations between regions. These regions are obtained by grouping pixels based on similarity and proximity. The slice level attributed graphs are then coerced to form a volumetric attributed graph, where volumetric consistency can be verified. The main novelty of our approach is in the use of the volumetric graph to ensure consistency from symbolic representations obtained from individual slices. In this fashion, the system allows errors to be made at the slice level, yet removes them when the ...
AbstractPurpose: To implement and examine the feasibility of a three-dimensional (3D) ultrashort TE (UTE) sequence on a 7 Tesla (T) clinical MR scanner in comparison with 3T MRI at high isotropic resolution. Materials and Methods: Using an in-house built saddle coil at both field strengths we have imaged mid-diaphysial sections of five fresh cadaveric specimens of the distal tibia. An additional in vivo scan was performed at 7 Tesla using a quadrature knee coil. Results: Using the same type of saddle coil at both field strengths, a significant increase in SNR at 7T compared with 3T (factor 1.7) was found. Significantly shorter T2* values were found at the higher field strength (T2* = 552.2 126 s at 7T versus T2* = 1163 391 s at 3T). Conclusion: UHF MRI at 7T has great potential for imaging...
Both the increased complexity of integrated circuits, resulting in six or more levels of integration, and the increasing use of flip-chip packaging have driven the development of integrated circuit (IC) failure analysis tools that can be applied to the backside of the chip. Among these new approaches are focused ion beam (FIB) tools and processes for performing chip edits/repairs from the die backside. This paper describes the use of backside FIB for a failure analysis application rather than for chip repair. Specifically, they used FIB technology to prepare an IC for inspection of voided metal interconnects (lines) and vias. Conventional FIB milling was combined with a super-enhanced gas assisted milling process that uses XeF{sub 2} for rapid removal of large volumes of bulk silicon. This combined approach allowed removal of the TiW underlayer from a large number of Ml lines simultaneously, enabling rapid localization and plan view imaging of voids in lines and ...
A new dedicated UHV STM for investigations at T#<=#5 K is presented. To achieve such low temperatures and to ensure a high thermal stability, the low-temperature (LT) STM described here has a concentric system of bath cryostats. There are openings for tip and sample exchange at low T, and windows with an infrared radiation shield for optical access, which can both be closed by a door mechanism for LT-STM measurements. Efficient vibration isolation is realized by using spring suspension with eddy current damping. With the 3-d coarse positioning unit any region of interest within 5 mm by 5 mm on the sample is accessible even at 5 K. For short turn-around cycles the sample and tip can both be exchanged at low temperatures. Atomically resolved images of Au(111) at 5 K in UHV demonstrate the excellent performance of this LT STM. As a typical application example the appearance of a charge-density wave on NbSe_2, which occurs ...
The K{beta}-to-K{alpha} X-ray intensity ratio of Ni in Ni{sub 3}Si, Ni{sub 2}Si and NiSi has been determined by energy dispersive X-ray fluorescence technique. It is found that the intensity ratio of Ni decreases from pure Ni to Ni{sub 2}Si and then increases from Ni{sub 2}Si to NiSi, in good agreement with the electronic structure calculations cited in the literature. We have also performed band structure calculations for pure Ni in various atomic configurations by means of linear muffin-tin orbital method and used this data with the normalized theoretical intensity ratios cited in the literature to estimate the 3d-occupation numbers of Ni in Ni-Si alloys. It is emphasized that investigation of alloying effect in terms of X-ray intensity ratios should be carried out for the stoichiometric alloys in order to make reliable and quantitative comparisons between theory and experiment in transition metal alloys.
A number of fragment ion onsets from the photoionization of CH/sub 3/SCCSCH/sub 3/ and CH/sub 3/SSSCH/sub 3/ have been measured. In addition, our experiment has been converted to a molecular beam source which will increase the precision of our measurements. Exhaustive oxidation of the divalent sulfur to sulfonic acids serves to quench the effects of quadrupolar broadening and thereby allowing for quantitative evaluation of structurally similar sulfonic acids. W/sub 1/2/ are reduced to < 25 Hz at 19 MHz (57,500 Gauss). Electronegative substituents shield the /sup 33/S nucleus perhaps imploying more efficient 2p-3d..pi.. backbonding between sulfur and oxygen. ..cap alpha..-Hetero substituents of sulfonyl groups do not influence the shift of the /sup 33/S to a dramatic extent. The exception is the dianion of thiosulfate compared to the dianion of sulfate. Lanthanide shift reagents, (Eu(fod)/sub 3/), are potentially useful ...
Quantitative structure activity relationship (QSAR) analysis of the correlations between initial brain uptake and structure parameters, for example lipophilicity F_r, molar refractivity MR and electronic parameters #sigma#_1 of the "9"9Tc"m-N_2S_2 complexes have been studied with multiple regression analysis method. The main structural factors which affect the initial brain uptake of this kind of brain imaging agents have been discussed. The results may give some theoretical information for designing new brain imaging agents
Abstract Copper(II) bis(thiosemicarbazone) are very useful for blood flow and hypoxic imaging. The aim of this study was to identify structure-activity relationships (SARs) within a series of analogues with different substitution patterns in the ligands, in order to design improved hypoxia imaging agents and elucidate hypoxia selectivity mechanisms. Genetic algorithms (GAs) were used to develop specific copper metal-ligand force field parameters for the MM3 force-field calculations. These new parameters produced results in good agreement with experiment and previously reported copper metal-ligand parameters. A successful quantitative SAR (QSAR) for predicting the several classes of Cu(II)-chelating ligands was built using a training set of 21 Cu(II) complexes. The QSAR exhibited a correlat...
Quantitative bone scintigraphy was performed on 23 white females with post-menopausal osteoporosis and vertebral compression fractures. These patients were then entered into a randomized, double-blind clinical trial or sodium fluoride therapy (NaF=14, placebo=9) which included repeat bone scintigraphy every six months. Scintigraphic images were acquired for 500K counts per image over the total body with computer acquisition over the posterior thoracic and lumbar spine. Images were obtained on a wide field-of-view gamma camera two hours after injecting 15 mCi of Tc-99m MDP. Data analysis showed a significant reduction in the activity ratio of abnormal vertebral body to normal vertebral body in those patients treated with sodium fluoride (paired t-test p=0.0095). No significant change was observed in the control group of (p=0.142). These results suggest that sodium fluoride therapy promotes more rapid ...
Purpose/Objective: At present, treatment verification between portal and reference images is performed based on manually-identified features by radiation oncologist, which is both time-consuming and potentially error-prone. There is a demand for the computerized verification procedure in clinical application. The purpose of this study is to develop a computerized portal verification scheme for pelvic treatment fields. Materials/Methods: The automated verification system involves image acquisition, image feature extraction, feature matching between reference and portal images and quantitative evaluation of patient setup. Electronic portal images with a matrix size of 256 x 256 and 12 bit gray levels were acquired using a liquid matrix electronic portal imaging device. Simulation images were acquired by digitizing ...
In this paper we present the results of time series analysis for a coal mining region based on partial unmixing. We test the method also known as mixture tuned matched filtering on an eight image Landsat 5 TM and Landsat 7 ETM+ time series covering the period from 1987 to 2003. Common change detection methods often include the comparison of two interactively generated classification results, such as derived from Maximum Likelihood classification. These approaches often yield highly accurate results. However, disadvantages include a strong analyst bias and hardly repeatable results. For a quantitative monitoring of a single surface class' development over time they are often not recommendable. Our goal was to test an unbiased quantitative way to assess the development of coal surfaces, such...
To study the three-dimensional (3D) magnetic field topology and its long-term evolution associated with the X3.4 flare of 2006 December 13, we investigate the coronal relative magnetic helicity in the flaring active region (AR) NOAA 10930 during the time period of December 8-14. The coronal helicity is calculated based on the 3D nonlinear force-free magnetic fields reconstructed by the weighted optimization method of Wiegelmann, and is compared with the amount of helicity injected through the photospheric surface of the AR. The helicity injection is determined from the magnetic helicity flux density proposed by Pariat et al. using Solar and Heliospheric Observatory/Michelson Doppler Imager magnetograms. The major findings of this study are the following. (1) The time profile of the coronal helicity shows a good correlation with that of the helicity accumulation by injection through ...
This topical report is a compilation of characterizations by different disciplines of the Mississippian Ratcliffe in portions of Richland County, MT. Goals of the report are to increase understanding of the reservoir rocks, oil-in-place, heterogeneity and methods for improved recovery. The report covers investigations of geology, petrography, reservoir engineering and seismic. The Ratcliffe is a low permeability oil reservoir which appears to be developed across much of the study area and occurs across much of the Williston Basin. The reservoir has not been a primary drilling target in the study area because average reserves have been insufficient to payout the cost of drilling and completion despite the application of hydraulic fracture stimulation. Oil trapping does not appear to be structurally controlled. For the Ratcliffe to be a viable drilling objective, methods need to be developed for (1) targeting better reservoir development and (2) better completions. A geological model is ...
The implementation of a three-dimensional conformal radiotherapy facility in the radiotherapy department of the Heinrich Heine University is described. Complex radiotherapy techniques with commercially available networked systems are introduced to improve clinical work. Over 18 month we have gained clinical experience with a PHILIPS Multileaf Collimator (MLC) mounted on a SL 25 linear accelerator. For a limited period the MLC was used as a conventional blocking device. The standard MLC-shapes are controlled with a stand-alone computer system. In addition, a three-dimensional treatment planning system (3-D-TPS / TMS-Radix, Helax AB) based on convolution/superposition algorithms was recently installed. Treatment optimization is achieved using static field arrangements with complete volumetric computerized tomographic patient data for 3-D-TPS. Conformal adaptation of the 95%-isodose to the Planning Target ...
A large part of mechanical and durability characteristics of cement-based materials comes from the performances of the hydrated cement, cohesive matrix surrounding the granular skeleton. Experimental studies, in situ or in laboratory, associated to models, have notably enhanced knowledge on the cement material and led to adapted formulations to specific applications or particularly aggressive environments. Nevertheless, these models, developed for precise cases, do not permit to specifically conclude for other experimental conclusions. To extend its applicability domain, we propose a new evolutive approach, based on reactive transport expressed at the microstructure scale of the cement. In a general point of view, the evolution of the solid compounds of the cement matrix, by dissolutions or precipitations, during chemical aggressions can be related to the pore solution evolution, and this one relied to the ionic exchanges with the external environment. By the utilization of a ...
Following the conventional X-ray diagnosis of the skull and upper cervical spine, CT proved to be the primary diagnostic method after a skull and brain injury: For all 4 cases we succeeded in detecting the occipital condyle fracture and in determing its size and location by reconstructions (coronal, sagittal, 3-D). In the case of complex occompanying injuries like soft tissue hematomas (cerebral, in the spinal cord, and the soft tissue of the neck) or for the detection of brain stem contusion, MRT had significant advantages. MRT can offer a higher image quality in soft tissue, especially in the spinal cord and the brain. (orig.) [Deutsch] Im Anschluss an die konventionelle Roentgendiagnostik des Schaedels und der Halswirbelsaeule, erwies sich die Computertomographie als primaer einzusetzendes diagnostisches Verfahren, nach erlittenem Schaedel-Hirn-Trauma. In allen Faellen gelang der exakte Frakturnachweis an den ...
This research aims at elucidating thermal hydraulic phenomena by carrying out their visualization and measurement which are difficult by conventional method, utilizing the excellent properties of real time neutron radiography and showing the usefulness of neutron radiography. The experiments were carried out on the visualization and measurement of liquid metal flow and mixed phase flow and the visualization and diagnosis of mixed phase flow equipment. As the achievement in this fiscal year, the image-processing method for visualizing quantitatively the distribution of void fraction in gas-liquid two-phase flow has been devised, therefore, its method and results are reported. For the analysis of multi-dimensional two-phase flow, in order to prepare the model and determine the constitution equation, the data on the multi-dimensional distribution of void fraction are required. Void fraction is defined. The method of image ...
Quantitative gated SPECT (QGS) was evaluated in 7 normal volunteers and 31 patients with cardiac diseases. Adequate cut off value of a prefilter was 0.45. In phantom, the left ventricular volume value was 93.9% of determined value by 180-degree projection in L type and 98.8% by 360-degree projection in opposed type. In normal volunteers, LVEF measured by QGS program related to value by first pass method. As for functional map, regional EF and wall motion decreased at the septum side, and wall thickening at base side of heart. Good correlation was recognized (p<0.0001) between blood flow image and functional map (regional EF and wall thickening). In 20 cases of acute myocardial infarction, lesion was detected conspicuously in regional EF and wall motion. The accuracy of coronary arterial stenosis improved in functional map (regional EF 92%, wall motion 92% and wall thickening 88%). In particular, the accuracy of 3 rami lesion was 100% in ...
We developed a new breast surface coil for the supine position. The subjects consisted of 9 patients with breast cancer varying from 46 to 60 years of age (average: 52). The cancer image of the SPGR (CE+) method was compared with that of the FSMTC (MTC-SPGR (CE+)) method and that of the FSMTC (MTC-SPGR with fat-saturation (CE+)) method in the sagittal section after injection of Gd-DTPA (0.1 mmol/kg). Quantitative analyses were performed before and after injection of Gd-DTPA in 6 patients. Three patients were excluded from the quantitative analyses owing to the clear detection of tumors in the fat tissue. Signal intensity measurements were systematically performed in each region of interest (ROI), i.e. the cancer lesion, the surrounding mammary gland. Statistical analyses showed significant differences between the lesions using the FSMTC (MTC-SPGR (CE+)), and the FSMTC (MTC-SPGR with fat-saturation (CE+)) methods and the ...
In the search for new brain imaging agents for use with single photon emission computed tomography (SPECT), quantitative structure activity relationship (QSAR) analysis of the correlations between initial brain uptake and physicochemical parameters like lipophilicity, log P, molecular weight, log MW and log U/D (undissociated/dissociated), of the {sup 99m}Tc-DADT (diaminedithiol) complexes and {sup 99m}Tc-PAO (propyleneaminoxime) complexes have been analyzed. High correlations are found for both the {sup 99m}Tc-DADT complexes (r = 0.94) and for the {sup 99m}Tc-PAO complexes (r = 0.83) which are significant at 99.9 and 99.5 percentile level, respectively. These results will help the further design of better ligands for {sup 99m}Tc in brain imaging. (author).
In this paper, we put forward a systematic method to analyze, control and evaluate the safety issues of medical robotics. We created a safety model that consists of three axes to analyze safety factors. Software and hardware are the two material axes. The third axis is the policy that controls all phases of design, production, testing and application of the robot system. The policy was defined as hazard identification and safety insurance control (HISIC) that includes seven principles: definitions and requirements, hazard identification, safety insurance control, safety critical limits, monitoring and control, verification and validation, system log and documentation. HISIC was implemented in the development of a robot for urological applications that was known as URObot. The URObot is a universal robot with different modules adaptable for 3D ultrasound image-guided interstitial laser coagulation, radiation seed ...
SAFT-UT technology is shown to provide significant enhancements to the inspection of materials used in US nuclear power plants. This report provides guidelines for the implementation of SAFT-UT technology and shows the results from its application. An overview of the development of SAFT-UT is provided so that the reader may become familiar with the technology. Then the basic fundamentals are presented with an extensive list of references. A comprehensive operating procedure, which is used in conjunction with the SAFT-UT field system developed by Pacific Northwest Laboratory (PNL), provides the recipe for both SAFT data acquisition and analysis. The specification for the hardware implementation is provided for the SAFT-UT system along with a description of the subsequent developments and improvements. One development of technical interest is the SAFT real time processor. Performance of the real-time processor is impressive and comparison is made of this dedicated parallel processor to a ...
A novel method to detect and correct inaccuracies in a set of unconstrained dense correspondences between two images is presented. Starting with a robust, general-purpose dense correspondence algorithm, an initial pose estimate and dense 3D scene reconstruction are obtained and bundle-adjusted. Reprojection errors are then computed for each correspondence pair, which is used as a metric to distinguish high and low-error correspondences. An affine neighborhood-based coarse-to-fine iterative search algorithm is then applied only on the high-error correspondences to correct their positions. Such an error detection and correction mechanism is novel for unconstrained dense correspondences, for example not obtained through epipolar geometry-based guided matching. Results indicate that correspondences in regions with issues such as occlusions, repetitive patterns and moving objects can be identified and corrected, such that a more ...
The Girassol field is located in Angolan deep water of Block 17 and consists of large vertically stacked turbidities complexes. The reservoir extends over approximately 200 km{sup 2} and water depth ranges between 1300 and 1400 meters. In that context High Resolution 3D seismic became the most valuable tool to describe and monitor the reservoir. The field development plan took into account, through re-injection of the gas into the reservoir, Total environmental policy imposing the recycling of production gas. Monitoring of this injection was the main reason to shoot the first High Resolution 4D extremely early in the life of field. Despite the complexity of interpretation due to complex fluid situation and pressure effect, the results went way beyond expectations as the 4D images are of very high quality. Data has also been used to update and refine the reservoir flow model as well as to help deciding on the location of ...
Complete text of publication follows. According to the new European regulations (Restrictions of Hazardous Substance Directive), there is an emerging demand for environmental friendly metal treatments instead on formerly used chromate conversion coating technique. The aim of the present investigations was to characterise and compare silicon containing protective thin layers on roughened galvanized steel surfaces (with average roughness of 0.7 microns), using FTIR microscopy and imaging techniques. The silicon containing coatings were produced either by Chemical Vapour Deposition (CVD) or by wet chemical treatment using liquid silane. FTIR techniques offer new possibilities in the characterisations and chemical mapping of differently coated thin films, besides SEM+EDS, AFM, nanoindentation, XPS measurements (P. Nemeth et al., Materials Science Forum, 589 (2008) 433-438). All measurements were carried out by a Varian FTS-7000 spectrometer with a 'Stingray' microscope ...
We have demonstrated that optical images can be stored in transparent lead-lanthanum-zirconate-titanate (PLZT) ceramics by exposure to near-UV light with photon energies greater than the band gap energy of approx. equal to 3.35 eV. The image storage process relies on optically induced changes in the switching properties of ferroelectric domains (photoferroelectric effect). Stored images are nonvolatile but can be erased by uniform UV illumination and simultaneous application of an electric field. Although high quality images, with contrast variations of >= 100:1 and spatial resolution of approx. equal to 10 #mu#m, can be stored using the photoferroelectric effect, relatively high exposure energies (approx. equal to 100 mJ/cm"2) are required to store these images. This large exposure energy severely limits the range of possible applications of nonvolatile ...
... CT angiograph for the peripheral rteries. a beautiful 3D-vision on the structures inside e chest. Okay. ... have an angled camera here. This is a 3D camera, and the surgeon has got th What ...
The authors have performed I-123 IMP single- photon emission CT (SPECT) brain imaging on seven mildly demented patients with acquired immunodeficiency syndrome (AIDS) and on seven normal subjects. Pixel-intensity histograms have been analyzed for the fraction of pixels in the lowest quartile of the intensity range. This fraction (F) averaged 17.7% (standard deviation [SD] = 4.3) in the AIDS group and 12.6 (SD = 4.7) in the normal group (P <.05). Regression analysis of neuropsychological testing (NPT) scores vs F yielded a correlation coefficient of.71. The presence or degree of atrophy did not correlate with F or NPT scores.
To understand dynamic developmental processes, living tissues must be imaged frequently and for extended periods of time. Root development is extensively studied at cellular resolution to understand basic mechanisms underlying pattern formation and maintenance in plants. Unfortunately, ensuring continuous specimen access, while preserving physiological conditions and preventing photo-damage, poses major barriers to measurements of cellular dynamics in indeterminately growing organs such as plant roots. We present a system that integrates optical sectioning through light sheet fluorescence microscopy with hydroponic culture that enables us to image at cellular resolution a vertically growing Arabidopsis root every few minutes and for several consecutive days. We describe novel automated routines to track the root tip as it grows, track cellular nuclei and identify cell divisions. We demonstrate the system's capabilities by collecting data on ...
In 15 patients (16 hip joints) we found the clinical and radiological signs of BMOS. On T1-weighted MRI images areas of low signal intensity could be observed in the head, neck and the intertrochanteric region of the femur in various extensions. These areas showed a significant increase in signal intensity on the T2-weighted images. Because pain was resistant to conservative therapy all these patients were treated by core decompression of the femoral head in a prospective study. Bone cores were evaluated histologically using undecalcified sections and quantitative microradiography. The existence of intramedullary oedema in exactly the regions exhibiting the MRI pattern of bone marrow oedema was verified histologically; however, bone and marrow changes similar to those of early avascular necrosis (AVN) were also visible. (orig.)
Twenty-six patients with late complications following femoral neck fracture were examined with both skeletal and bone marrow radionuclide scintimetry. There was no correlation between the methods with respect to the quantitative assessment of femoral head vascularity based on different uptake ratios comparing the fractured and the intact side. Skeletal scintimetry always had good image quality and permitted reliable differentation between nonunion of the fracture and late segmental collapse, in contrast to bone marrow scintimetry which gave poor image quality. Skeletal scintimetry thus seems superior to bone marrow scintimetry for assessment and differential diagnosis of late complications following femoral neck fracture. It is emphasized that the physiological mechanisms for radionuclide uptake must be taken into account when comparing scintimetric studies using different tracers.
Twenty-six patients with late complications following femoral neck fracture were examined with both skeletal and bone marrow radionuclide scintimetry. There was no correlation between the methods with respect to the quantitative assessment of femoral head vascularity based on different uptake ratios comparing the fractured and the intact side. Skeletal scintimetry always had good image quality and permitted reliable differentation between nonunion of the fracture and late segmental collapse, in contrast to bone marrow scintimetry which gave poor image quality. Skeletal scintimetry thus seems superior to bone marrow scintimetry for assessment and differential diagnosis of late complications following femoral neck fracture. It is emphasized that the physiological mechanisms for radionuclide uptake must be taken into account when comparing scintimetric studies using different tracers. (author).
Positron emission tomography (PET) is a fully quantitative technology for imaging metabolic pathways and dynamic processes in vivo. Attenuation correction of raw PET data is a prerequisite for quantification and is typically based on separate transmission measurements. In PET/CT attenuation correction, however, is performed routinely based on the available CT transmission data. Recently, combined PET/magnetic resonance (MR) has been proposed as a viable alternative to PET/CT. Current concepts of PET/MRI do not include CT-like transmission sources and, therefore, alternative methods of PET attenuation correction must be found. This article reviews existing approaches to MR-based attenuation correction (MR-AC). Most groups have proposed MR-AC algorithms for brain PET studies and more recently also for torso PET/MR imaging. Most MR-AC strategies require the use of complementary MR and transmission images, ...
Early white matter (WM) injury affects brain maturation in preterm infants as revealed by diffusion tensor imaging and volumetric magnetic resonance (MR) imaging at term postmenstrual age (PMA). The aim of the study was to assess quantitatively brain maturation in preterm infants with and without milder forms of WM damage (punctate WM lesions, PWML) using conventional MRI. Brain development was quantitatively assessed using a previously validated scoring system (total maturation score, TMS) which utilizes four parameters (progressive myelination and cortical infolding, progressive involution of glial cell migration bands and germinal matrix tissue). PWML were defined as foci of increased signal on T1-weighted images and decreased signal on T2-weighted images with no evidence of cystic degeneration. A group of 22 preterm infants with PWML at term PMA (PWML group) ...
The authors compared unenhanced and contrast-enhanced fast MRI and Computerized Tomography in the detection of liver metastases. Eleven patients with single or multiple hepatic lesions (42 in all) were submitted to V and magnetic resonance studies; T1- and T2- weighted TSE, T2-weighted TSE with fat suppression, unenhanced breath-hold TFE and early or delayed enhanced breath-hold TFE images were acquired with a 1.5 T superconductive magnet (Philips NT). The quantitative analysis of all magnetic resonance images was performed for contrast/noise ratio (CNR) and number of detected lesions; magnetic resonance and Computerized Tomography images were also compared qualitatively for lesion conspicuity, anatomical structure identification and artifacts. The results were compared with Student's test. Early enhanced breath-hold TFE was statistically superior to T1-weighted TSE (p = .0009), T2-weighted TSE (p = ...
The refrigerant two-phase flows in a distributor and a simulated plate heat exchanger with a single passage used in a compression-type refrigerator were visualized by real-time neutron radiography. For a distributor, the liquid fraction in the each tube was measured by some image processing method. On the other hand, for a plate heat exchanger, the two-dimensional distribution of void fraction was measured quantitatively by the umbra method. As a result, it was shown that the dynamic behaviors of refrigerant at the inlet of the section strongly affected on the performance, that is, a distribution performance of a distributor and a liquid distribution in a plate heat exchanger. (author)
An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.
The addition of carbon to samples, during imaging, presents a barrier to accurate TEM analysis, the controlled deposition of hydrocarbons by a focused electron beam can be a useful technique for local nanometer-scale sculpting of material. Here we use hydrocarbon deposition to form nanopores from larger focused ion beam (FIB) holes in silicon nitride membranes. Using this method, we close 100-200nm diameter holes to diameters of 10nm and below, with deposition rates of 0.6nm per minute. I-V characteristics of electrolytic flow through these nanopores agree quantitatively with a one dimensional model at all examined salt concentrations.
The simulation of processes in engineering and the physical sciences has progressed rapidly over the last several years. With rapid developments in supercomputers, parallel processing, numerical algorithms and software, scientists and engineers are now positioned to quantitatively simulate systems requiring many billions of arithmetic operations. The need to understand and assimilate such massive amounts of data has been a driving force in the development of both hardware and software to create visual representations of the underling physical systems. In this paper, and the accompanying videotape, the evolution and development of the visualization process in scientific computing will be reviewed. Specific applications and associated imaging hardware and software technology illustrate both the computational needs and the evolving trends. 6 refs.
Parallel imaging and echo sharing techniques have markedly reduced the acquisition times for MRI of large volumes. Dynamic 2 and 3-dimensional data sets of the chest with high temporal resolution (up to 10 images/s with single slice and 2 volume/s) allow an analysis of respiratory motion of the lungs and tumors. Time-resolved 2D series in preselected planes can be used to observe respiratory motion during free breathing or after respiratory commands, e.g. to exclude chest wall invasion by a tumor or for diagnosing impairment of respiratory mechanics. Time-resolved 3D-series (4D-MRI) allow monitoring of the spatial displacement of the lungs and tumors as a whole volume. Present limitations such as an overestimation of tumor size and an underestimation of displacement due to a limited temporal resolution are expected to be overcome with further technical developments. However, 4D-MRI already appears to be ...
The purpose of this paper is to demonstrate how recent experimental results of "1"5"1Eu and "5"7Fe high pressure Moessbauer studies in 4f and 3d metallic magnetic systems can contribute to a deeper understanding of the nature of local moment (4f) and itinerant (3d) magnetism in these systems. Special emphasis is given on the comparison of the experimental results with related theoretical models. (orig.).
The mixture of 1,3-dichloropropene (1,3-D) and chloropicrin (CP) is used as a preplant soil fumigant. In comparison with individual fumigants, application of a mixture may affect the environmental dissipation and fate of each chemical, such as emission and degradation. We investigated the degradation of CP, 1,3-D, and their mixture in fresh soils and sterile soils, and evaluated the competitive characteristic of fumigants in the mixture. The degradation of low concentrations of CP in fresh soil was accelerated at early times in the presence of 1,3-D, whereas the addition of CP reduced the degradation rate of trans-1,3-D, possibly by inhibiting the activity of trans-1,3-D degrading microorganisms. The potential of applying amendments to the soil to increase the rate of CP and ...
3d occupation numbers of the transition elements corresponding to various types of atomic configurations are calculated by means of the linear muffin-tin orbital (LMTO) method. This data is used with the multiconfiguration Dirac-Fock (MCDF) X-ray intensity ratios to estimate the electron populations of the 3d metals in alloys.
3d occupation numbers of the transition elements corresponding to various types of atomic configurations are calculated by means of the linear muffin-tin orbital (LMTO) method. This data is used with the multiconfiguration Dirac-Fock (MCDF) X-ray intensity ratios to estimate the electron populations of the 3d metals in alloys.
The treatment of bony, osteochondral, and ligamentous injuries of the tibio-talar requires precise preoperative planning by radiological investigation. This is essential to a correct understanding of the underlying pathology and will allow a proper classification of the injury, which is the basis of treatment. Conventional radiography using anteroposterior and lateral X-rays with comparative views of the noninjured side and, if necessary, rotated spot views and tomography are of high value especially in osteochondral fractures of the talus. Intraoperative control images in both planes after osteosynthesis are mandatory. For evaluation of the postoperative course and severity of arthrosis formation, the classification system of Bargon has proved its worth. In addition, tomography of the tibio-talar joint in two planes is useful especially in tibial pilon fractures, some malleolar fractures, and peripheral talar fractures. In talar fracture dislocations with ...
As the jump from 2D to 3D, seismic exploration lives a new revolution with the use of converted PS waves. Indeed PS converted waves are proving their potential as a tool for imaging through gas; lithology discrimination; structural confirmation; and more. Nevertheless, processing converted shear data and in particular determining accurate P and S velocity models for depth imaging of these data is still a challenging problem, especially when the subsurface is anisotropic. To solve this velocity model determination problem we propose to use reflection travel time tomography. In a first step, we derive a new approximation of the exact phase velocity equation of the SV wave in anisotropic (TI) media. This new approximation is valid for non-weak anisotropy and is mathematically simpler to handle than the exact equation. Then, starting from an isotropic reflection tomography tool developed at Lt-'P, ...
Purpose. We have tested a procedure of focal injection of the contrast medium Lipiodol as a fiducial marker for image-guided boost of the tumor in bladder cancer radiotherapy (RT). In this study, we have evaluated the feasibility and the safety of the method as well as the inter- and intra-fraction shift of the bladder tumor. Materials and methods. Five patients with muscle invasive urinary bladder cancer were included in the study. Lipiodol was injected during flexible cystoscopy into the submucosa of the bladder wall at the periphery of the tumor or the post resection tumor-bed. Cone-beam CT (CBCT) scans were acquired daily throughout the course of RT. Results. Lipiodol demarcation of the bladder tumor was feasible and safe with only a minimum of side effects related to the procedure. The Lipiodol spots were visible on CT and CBCT scans for the duration of the RT course. More than half of all the treatment fractions required a geometric shift of 5 mm or more to ...
We present an image of the rupture propagation of the 2004 M6.0 Parkfield earthquake using records from a dense network of local strong motion stations. We back-propagate high-frequency waveforms in 3D with a method, similar to reverse time migration, to obtain an estimate of the distribution of radiated high-frequency seismic energy in space and time. The image is forced to be coherent at the known hypocenter location and the quake origin time by applying small static time shifts obtained using waveform cross-correlation. We observe that the Parkfield earthquake radiated a distinct secondary high-frequency phase, which is located about 12.5~km northwest of the hypocenter with an onset of seismic radiation about 5~s after the rupture initiation. The time history of the back-projection suggests a rupture velocity of 2.5~km/s between hypocenter and subevent. The back-projection result is confirmed by ...
This paper reports, to complement current knowledge on brain development, late regional brain maturation assessed with quantitative MR imaging. Axial and coronal head spin-echo (SE) images were obtained in 60 healthy individuals aged 5--56 years, with a double-echo, flow compensated imaging sequence obtained with a 1.5-T Magnetom spectroscopy and imaging system. T2-weighted images were calculated from the intensity differences in SE images at echo times (TEs) of 15 and 90 msec (TR = 2.5 second). The mean T2 values were determined at 16 sites in each cerebral hemisphere. T2 values of the six frontal subcortical white matter (FSCWM) sites and of the internal capsule (IC) were evaluated. Mean T2 values in the IC decreased until age 10 years, whereas this decrease continued in the FSCWM past age 15 years before reaching a plateau. Differential ...
Optional multiple long-axial gated blood pool SPECT images were prepared for the purpose of stereoscopic and quantitativeimaging of left ventricular wall motion (LVWM). Sixteen patients with ischemic heart disease and 8 healthy subjects were imaged in 32 views in the 360 degrees position after iv injection of 740 MBq of Tc-99m-labeled human serum albumin D. The R-R interval was divided into 16. After preparing conventional oblique images, long-axial images were prepared. Shortening rate of left ventricular wall was calculated in 5 segments of the apex and base of the left ventricle. An average shortening rate in each segment was graded with a score from a minimum of 0 to a maximum of 40% or more. In the normal group, shortening rate in each segment, except for the base of the septal region, exceeded 40%. In the group of ischemic heart disease, radial shortening ...
Forests on the Kola Peninsula in Northern Russia grow close to the northern tree line. They are subjected to both natural and anthropogenic stress factors. The Cu-Ni smelter 'Severonikel' (Lat. 67 deg 55'N; Long. 32 deg 57'E) near Monchegorsk is one of the two major sources of sulphur dioxide and heavy metals emissions on the Kola Peninsula. These emissions have caused significant deterioration of the surrounding vegetation. The thesis demonstrates how methods of Remote sensing, ground survey and mathematical modelling can be integrated for monitoring of the smelter's environmental impact on the surrounding vegetation: ground truth data are used for calibration of remote-sensed data, which further serve to verify mathematical models. The study aims were: * to estimate the scale of airborne sulphur pollution from the smelting industry on the Kola Peninsula and its effect on vegetation; * to assess spatial extent of the forest decline in the ...
Tolerancing of assembly mechanisms is a major interest in the product life cycle. One can distinguish several models with growing complexity, from 1-dimensional (1D) to 3-dimensional (3D) (including form deviations), and two main tolerancing assumptions, the worst case and the statistical hypothesis. This paper presents an approach to 3D statistical tolerancing using a new acceptance criterion. Our approach is based on the 1D inertial acceptance criterion that is extended to 3D and form acceptance. The modal characterisation is used to describe the form deviation of a geometry as the combination of elementary deviations (location, orientation and form). The proposed 3D statistical tolerancing is applied on a simple mechanism with lever arm. It is also compared to the traditional worst-case tolerancing using a tolerance ...
Three-dimensional seismic wavefields may be extrapolated in depth, one frequency at a time, by two-dimensional convolution with a circularly symmetric, frequency- and velocity-dependent filter. This depth extrapolation, performed for each frequency independently, lies at the heart of 3-D finite-difference depth migration. The computational efficiency of 3-D depth migration depends directly on the efficiency of this depth extrapolation. McClellan transformations provide an efficient method for both designing and implementing two-dimensional digital filters that have a particular form of symmetry, such as the circularly symmetric depth extrapolation filters used in 3-D depth migration. Given the coefficients of one-dimensional, frequency- and velocity-dependent filters used to accomplish 2-D depth migration, McClellan transformations lead to a simple and efficient ...
Human beings are confronted with another grievous disaster - coal fire. The monitoring on underground coal bed combustion relied on drilling supervising in the past, but this method is not good. By taking the coal fire of Gulaben mine in Inner Mongolia Autonomous Region as an example, the monitoring methods of underground coal bed combustion were explored based on the hyperspectra and high-resolution remote sensing technology. By employing the OMIS imaging apparatus developed by Shanghai Institute of Technical Physics of Chinese Academy of Sciences, the airborne hyperspectral images and the characteristic spectra of different types were obtained and the temperature was measured synchronously on the ground. Then according to the correlation of DN value of the thermal infrared band and surface temperature, the image information was processed, the spectral features were analyzed, and the surface temperature retrieval model was ...
We investigated the isotropic diffusion coefficient (D') and fractional anisotropy (FA) in white matter (WM) during brain development, using an optimised diffusion-tensor imaging (DTI) method with whole brain coverage in a clinically acceptable time. We images 52 children with no evident neurological abnormality (30 boys, 22 girls aged 1 day-16 years) using high-angle DTI with optimised temporal gradient performance. D' and FA were calculated in 10 regions of interest in white matter. We saw that the age-related reduction in D' and increase in FA follow a mono- or biexponential model in white matter, probably depending on the compactness and myelination rate of the fibre tracts. In contrast to other areas, in which adult values were reached during the third year, there is a trend to continuous increase in FA in all deep white-matter areas, suggesting continuing maturation and organisation of deep tracts not detected on conventional MRI. (orig.)
A first-principles task-based approach to the design of medical ultrasonic imaging systems for breast lesion discrimination is described. This study explores a new approximation to the ideal Bayesian observer strategy that allows for object heterogeneity. The new method, called iterative Wiener filtering, is implemented using echo data simulations and a phantom study. We studied five lesion features closely associated with visual discrimination for clinical diagnosis. A series of human observer measurements for the same image data allowed us to quantitatively compare alternative beamforming strategies through measurements of visual discrimination efficiency. Employing the Smith-Wagner model observer, we were able to breakdown efficiency estimates and identify the processing stage at which performance losses occur. The methods were implemented using a commercial scanner and a cyst phantom to explore development of spatial ...
For good image quality using ultrasound inverse scattering, one alternately solves the well-posed forward scattering equation for an estimated total field and the ill-posed inverse scattering equation for the desired object property function. In estimating the total field, error or noise contaminates the coefficients of both matrix and data of the inverse scattering equation. Previous work on ill-posed inverse ultrasonic scattering commonly used Tikhonov regularization, which considers error only in the data. The solution so obtained is not precise enough to reconstruct the quantitative internal structure of a large or high-contrast object. This paper adopts the truncated total least squares method, simultaneously considering error and noise on both sides of the inverse scattering equation, and compares it with the classical Tikhonov regularization. We show that it can substantially improve reconstruction fit and image ...
Purpose: The predictive potential of tumor cell kinetic parameters may be improved when they are studied in relation to other microenvironmental parameters. The purpose of this investigation was to quantitatively categorize human tumor samples according to proliferation patterns. Second, it was examined whether these characteristics are retained after xenotransplantation. Methods and Materials: Fifty tumor samples from head-and-neck cancer patients were immunohistochemically stained for Ki-67 and vessels. Also, parts of the samples were transplanted into nude mice. Tumors were categorized according to previously described patterns of proliferation. Vascular and proliferation patterns were analyzed using an image processing system. Results: The 50 tumors were categorized into four patterns of proliferation by visual assessment: marginal (6), intermediate (10), random (21), and mixed (12). One tumor could not be classified. These patterns were ...
A fast and accurate segmentation of organs at risk, such as the healthy colon, would be of benefit for planning of radiotherapy, in particular in an adaptive scenario. For the treatment of pelvic tumours, a great challenge is the segmentation of the most adjacent and sensitive parts of the gastrointestinal tract, the sigmoid and descending colon. We propose a semi-automated method to segment these bowel parts using the fast marching (FM) method. Standard 3D computed tomography (CT) image data obtained from routine radiotherapy planning were used. Our pre-processing steps distinguish the intestine, muscles and air from connective tissue. The core part of our method separates the sigmoid and descending colon from the muscles and other segments of the intestine. This is done by utilizing the ability of the FM method to compute a specified minimal energy functional integrated along a path, and thereby extracting the colon ...
Purpose/Objective. Daily Cone-beam computed tomography (CBCT) in room imaging is used to determine tumour shrinkage during a full radiotherapy (RT) course. In addition, relative interfractional tumour and lymph node motion is determined for each RT fraction. Material and methods. From November 2009 to March 2010, 20 consecutive lung cancer patients (14 NSCLC, 6 SCLC) were followed with daily CBCT during RT. The gross tumour volume for lung tumour (GTV-t) was visible in all daily CBCT scans and was delineated at the beginning, at the tenth and the 20th fraction, and at the end of treatment. Whenever visible, the gross tumour volume for lymph nodes (GTV-n) was also delineated. The GTV-t and GTV-n volumes were determined. All patients were setup according to an online bony anatomy match. Retrospectively, matching based on the internal target volume (ITV), the GTV-t or the GTV-n was performed. Results. In eight patients, we observed a significant GTV-t shrinkage ...
Qualitative technetium Tc 99m bone scintigraphy using phosphate compounds and gallium 67 scintigraphy were described as a helpful means in diagnosing necrotizing external otitis (NEO). They were, however, claimed to be nonspecific. Quantitative Tc 99m methylene diphosphonate bone scintigraphy and gallium 67 scintigraphy were performed in eight patients with NEO and in 20 patients with severe external otitis, in order to prove usefulness of scintigraphy in the diagnosis of NEO. Ratios of lesion to nonlesion for bone scintigraphy were 1.67 {plus minus} 0.16 in patients with NEO and 1.08 {plus minus} 0.09 in patients with severe external otitis, and for gallium 67 scintigraphy they were 1.35 {plus minus} 0.24 in NEO patients and 1.05 {plus minus} 0.03 in patients with severe external otitis. There was no difference in uptake between diabetic patients with severe external otitis and nondiabetic patients. The scintigraphic studies were also evaluated using a qualitative ...
Qualitative technetium Tc 99m bone scintigraphy using phosphate compounds and gallium 67 scintigraphy were described as a helpful means in diagnosing necrotizing external otitis (NEO). They were, however, claimed to be nonspecific. Quantitative Tc 99m methylene diphosphonate bone scintigraphy and gallium 67 scintigraphy were performed in eight patients with NEO and in 20 patients with severe external otitis, in order to prove usefulness of scintigraphy in the diagnosis of NEO. Ratios of lesion to nonlesion for bone scintigraphy were 1.67 #+-# 0.16 in patients with NEO and 1.08 #+-# 0.09 in patients with severe external otitis, and for gallium 67 scintigraphy they were 1.35 #+-# 0.24 in NEO patients and 1.05 #+-# 0.03 in patients with severe external otitis. There was no difference in uptake between diabetic patients with severe external otitis and nondiabetic patients. The scintigraphic studies were also evaluated using a qualitative scoring method (scores 0 to ...
A necessary condition for crevice corrosion is that a crevice former create a sufficiently tight, restricted geometry on the metal surface to support the development of critical crevice chemistry. Crevice corrosion is affected by the crevice geometry (tightness) and the properties of the crevice former. The objective of this study is to determine the effect of the crevice former material on the evolution of localized corrosion-damage. A standard crevice corrosion test method is modified by (a) the use of ceramic, metal or polymer materials as the crevice former and (b) the variation of size and shape of the crevice. This study focuses on the post initiation stage of crevice corrosion and addresses factors that may limit the initiation of localized corrosion and also slow or stop the continued propagation of corrosion. Controlled crevice corrosion tests are performed under aggressive, accelerated conditions on Ni-Cr-Mo alloy C-22 and other alloys for comparison. Multiple techniques are ...
The petroleum industry is increasing its focus on the exploration of reservoirs in turbidite systems. However, these sedimentary environments are often characterized by very complex sand distributions. Hence, reservoir description based on conventional seismic and well-log interpretation may be very uncertain. There is a need to employ more quantitative seismic techniques to reveal reservoirs units in these complex systems from seismic amplitude data. In this study we focus on North Sea turbidite systems. Our goal is to improve the ability to use 3D seismic data to map reservoirs in these systems. A cross-disciplinary methodology for seismic reservoir characterization is presented that combines rock physics, sedimentology, and statistical techniques. We apply this methodology to two turbidite systems of Paleocene age located in the South Viking Graben of the North Sea. First, we investigate the relationship between ...
Evaluation and interpretation of CT colonography is based on both 2D and 3D techniques. The 2D techniques are popular mainly because the time needed for evaluation is short. The 3D techniques allow better definition than the 2D techniques, especially of polyps close to folds or at the base of a fold. The evaluation strategies generally accepted so far (primarily 2D, with 3D for problem cases, or vice versa) demand knowledge of both 2D and 3D techniques. Newer 3D visualization techniques help make it possible to acquire more complete and faster recording particularly of areas that are not easily accessible to endoscopic examination. These user-friendly developments are thus well suited to improving the detection and the security of detection of polyps. It must be remembered that ...
Dynamic quantitative bone scintigraphy was performed on 31 men with prostatic carcinoma before orchiectomy as well as 2 weeks, 2 and 6 months postoperatively. After injection of technetium methylene diphosphonate Tc 99m ("9"9"mTc-MDP) the count rate was recorded as serial images over the lower thoracic and all the lumbar vertebrae from 1 to 240 min post-injection. Thirteen men had normal bone scintigrams with no changes in "9"9"mTc-MDP content at the four different investigation times. Eighteen men had skeletal metastases. Throughout the study half of the abnormal vertebrae in these patients showed an abnormal count rate after only 6 min post-injection. After 1 h it was possible in almost all abnormal vertebrae to predict abnormal bone uptake. In response to therapy a 'flare phenomenon' with an increase in count rate was seen 2 weeks after orchiectomy followed by a decrease 2 months postoperatively in most of the abnormal vertebrae. The count ...
In interventional radiology (IVR) of cerebral aneurysms, it is important to understand the form and physical relationships between the cerebral aneurysm and the surrounding vessels. However, because the vessels in the head area are highly complex, it can be difficult to comprehend the structure using conventional angiography. Therefore, three-dimensional rotational angiography (3D-RA) has been used in recent years. This article discusses studies of the spatial resolution of 3D-RA. We reconstructed 3D-RA of an acrylic slit phantom (slit widths: 0.5, 0.75, 1.0, 1.5 mm) and examined spatial resolution by visual evaluation and profile curves. When the slit phantom was arranged to avoid the effect of beam hardening, the spatial resolution of 3D-RA was found to be as high as 0.75 mm. When the slit phantom was placed orthogonal ...
A 2-D model has been proposed to investigate the approximate estimation of the natural convection heat loss from modified cavity receiver of without insulation (WOI) and with insulation (WI) at the bottom of the aperture plane in our previous article. In this paper, a 3-D numerical model is presented to investigate the accurate estimation of natural convection heat loss from modified cavity receiver (WOI) of fuzzy focal solar dish concentrator. A comparison of 2-D and 3-D natural convection heat loss from a modified cavity receiver is carried out. A parametric study is carried out to develop separate Nusselt number correlations for 2-D and 3-D geometries of modified cavity receiver for estimation of convective heat loss from the receiver. The results show that the 2-D and 3-D are comparable only at higher angle of ...
A technique for quantitative determination of cephalothin and desacetylcephalothin in serum using a method based on high-pressure liquid chromatography is described. Both compounds were quantitatively...Full Text Available
In the construction work for the Unit No.5 Turbine Building at Hamaoka Nuclear Power Station, the collaboration work for the planning and the coordination of the building construction and the machinery installation was carried out utilizing three-dimensional computer aided design (3D CAD) information. It was the first time in Japan for a building constructor and a plant manufacturer to work together, exchanging 3D CAD data of the whole building and adjusting the construction schedule. It was made possible to confirm the correspondence concerning the planning of both companies from the primary stage of the project by the total process simulation and to adjust on-going work precisely by the partial process simulation.
In the construction work for the Unit No.5 Turbine Building at Hamaoka Nuclear Power Station, the collaboration work for the planning and the coordination of the building construction and the machinery installation was carried out utilizing three-dimensional computer aided design (3D CAD) information. It was the first time in Japan for a building constructor and a plant manufacturer to work together, exchanging 3D CAD data of the whole building and adjusting the construction schedule. It was made possible to confirm the correspondence concerning the planning of both companies from the primary stage of the project by the total process simulation and to adjust on-going work precisely by the partial process simulation.
Porous flow occurs in a wide range of materials and applies to many commercially relevant applications such as oil recovery, chemical reactors and contaminant transport in soils. Typically, breakthrough and pressure curves of column floods are used in the laboratory characterization of these materials. These characterization methods lack the detail to easily and unambiguously resolve flow mechanisms with similar effects at the core scale that can dominate at the aquifer or oil field scale, as well as the effects of geometry that control the flow at interfaces as in a perforated well or the inlet of an improperly designed column. Non-invasive imaging techniques such as MRI have been shown to provide a far more detailed characterization of the properties of the solid matrix and flow, but usu...
The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.
339 CT und 95 MRT examinations in 210 partients were evaluated retrospectively to determine the value of CT and MRT for follow-up of head and neck tumors and for diagnosing recurrences. Semi-quantitative evaluation of tumor extent during and after radiotherapy showed advantages for MRT since changes induced by treatment, particularly oedema, produced less contrast loss in the images. CT had a sensitivity of 81% for the recognition of recurrences; this was 92% for MRT. Specificity for CT was 76% and for MRT 86%. Concerning the reliability of individual diagnostic criteria, space occupying lesions were the most valuable in CT diagnosis. For MRT, space occupying lesions and infiltration into neighbouring structures were of equal value. Because of differences in the nature of the signals, MRT proved better than CT in characterising recurrent masses and this improved the differentiation between scarring and local tumour recurrence. (orig.).
We propose a combined experimental (Atomic Force Microscopy) and theoretical study of the structural and dynamical properties of nucleosomes. In contrast to biochemical approaches, this method allows to determine simultaneously the DNA complexed length distribution and nucleosome position in various contexts. First, we show that differences in the nucleo-proteic structure observed between conventional H2A and H2A.Bbd variant nucleosomes induce quantitative changes in the in the length distribution of DNA complexed with histones. Then, the sliding action of remodeling complex SWI/SNF is characterized through the evolution of the nucleosome position and wrapped DNA length mapping. Using a linear energetic model for the distribution of DNA complexed length, we extract the net wrapping energy of DNA onto the histone octamer, and compare it to previous studies.
Guidelines for the viability primer component of the version 3 workbook. The Viability page in the current version of the Excel spreadsheet for conservation ... ...
A 2-D model has been proposed to investigate the approximate estimation of the natural convection heat loss from modified cavity receiver of without insulation (WOI) and with insulation (WI) at the bottom of the aperture plane in our previous article. In this paper, a 3-D numerical model is presented to investigate the accurate estimation of natural convection heat loss from modified cavity receiver (WOI) of fuzzy focal solar dish concentrator. A comparison of 2-D and 3-D natural convection heat loss from a modified cavity receiver is carried out. A parametric study is carried out to develop separate Nusselt number correlations for 2-D and 3-D geometries of modified cavity receiver for estimation of convective heat loss from the receiver. The results show that the 2-D and 3-D are comparabl...
... applications related to military and intelligence area ... the technology solved yet, but the open issue still ... fields, columns; ie data source, document type ...
mulation, with flow quantities stored at the grid vertices. OVERFLOW ..... attack: a separation bubble near the trailing edge of the ..... AGARD CP-429, Jul. 1988. ...
The meeting was arranged into the following sessions: introductory; advanced ceramics and ceramic composites; ceramic and metal matrix composites; electronic materials and devices; acoustoelasticity, stress, and texture; composites-porosity, strength, and UT propagation; process modeling and monitoring; thermal wave physics; material properties, composites, surfaces, and interfaces; acoustic emission; ferromagnetic materials; new sensors; NDE reliability assessment; elastic wave scattering and propagation; image analysis, data storage, and signal processing; UT transducers; weldments and bonded materials; eddy current models; unified life cycle engineering; x rays, CT, and NMR; eddy current probes and instruments; acoustic microscopy imaging, and reconstruction; signal processing, measurement techniques, and systems; NDE applications of artificial intelligence; crack behavior influenced by history; inversion procedures for UT and EC; process ...
Quantitative bone scintigraphy was performed in patients with prostatic carcinoma before orchiectomy as well as two weeks, two and six months after operation. The count rate was recorded as serial gamma camera images over the lower thoracic and all lumbar vertebrae from 1 to 240 min and at 24 h after injection of "9"9"Tc"m-MDP. In almost all abnormal vertebrae an increased count rate was observed within one hour after injection. Most of the vertebrae which were considered normal at 4 h after injection, but had an increased 24h/4h ratio developed into abnormal vertebrae later in the study. The patients with normal bone scintigrams showed no change in "9"9Tc"m-MDP uptake during the study. The reproducibility of quantitative bone scintigraphy was found to be #+-# 7% (1 SD). In response to therapy, most of the patients with abnormal bone scintigrams showed an increase in count rate two weeks after operation followed by a ...
Low resolution visual polarimetric photographic imagery of the Galveston Bay oil spill from a tanker accident on July 28, 1990 was obtained and analyzed. The low resolution imagery (30 to 100 meters) was obtained concurrently with high resolution (1 meter), and is representative of what would be seen by a polarimetric satellite. Orthogonal red-green-blue (RGB) polarimetric images obtained with color photography were digitized by KODALUX on to a CD ROM. These polarimetric images were then used to calculate the percent polarization. The positive and negative percent polarized radiation scattered by each of the sea surface waves is seen individually in high resolution imagery. (Percent polarization is defined as positive when the dominant radiation is perpendicular to the plane of incidence and negative when it is parallel). The analysis of low resolution polarimetry is approached in a different manner than high resolution; in high resolution, ...
Objectives: To minimize movement artifacts during tracer imaging studies, the animals are generally sedated. Although many reports describe the effect of barbiturates on brain function, less is published about the general impact on the extracerebral metabolism and tracer biodistribution. This report describes the influence of pentobarbital on tumor uptake of ["1"2"3I]-2-iodo-L-phenylalanine (["1"2"3I]-2I-L-PA) using dissection and nuclear imaging. Methods: R1M tumor-bearing athymic mice were divided into two populations: untreated and pentobarbital-treated. Each group was subjected to dynamic and static planar imaging and organ dissection after ["1"2"3I]-2I-L-PA injection. Two-compartment blood modeling was performed. Analysis of variance (ANOVA), t test and clustered boxplot analyses were used to compare the results between the treatment groups and between the data acquisition methods. Results: Two-compartment blood ...
Forty-four patients with small cell carcinoma of the bronchus underwent CT and MR studies of the brain to detect cerebral metastases. All patients were studied with contrast-enhanced CT scans, short (T1-weighted) and long (T2-weighted), spin-echo (SE) and FLASH 90 grades sequences were also obtained. A quantitative comparison of the results was carried out to assess the sensitivity of the different techniques in the detection of brain metastases according to lesion diameter. Metastases were identified in 19/44 patients (43%). All techniques detected the lesions >2 cm; of the metastases <2 cm, 63/124 (51%) were detected only by GdDTPA SE-T1 and FLASH sequences and 11 more (9%) only by Gd-DTPA SE-T1 scans. All the lesions identified oh enhanced CT scans or on T2-weighted images were easily detected by Gd-DTPA scans. CT sensitivity was higher than that of pre-contrast SE-T1 and FLASH studies and only slightly lower than that of T2-weighted ...
Quantitative evaluation of CRT and CR observations in indentification of malignancy using phantom and clinical data. A breast phantom and a total of 40 patients were imaged by Fuji computed radiography (FCR). The images were interpreted twice by six radiologists both on CR film (2510 x 2000 pixels x 10 bits, 0.1 mm spatial resolution) and on a CRT monitor (1568 x 1152 pixels x 10 bits, 0.1 mm pixel size with double expansion) with image processing parameters of a toutine (RN 1.0, RE 0.2), for a calcification (RN 9.0, RE 4.0) and for a mass (RN 7.0, RE 2.0). The forty clinical cases included breast diseases with calcifications, masses, and normal breasts. Two-tailed t-test was performed to analyze interpretation of simulated microcalcifications and masses in the phantom. The receiver operating characteristic (ROC) analysis was performed to evaluate clinical cases. In all interpretation studies using both ...
Monte Carlo (MC) dose calculations can be accurate but are also computationally intensive. In contrast, convolution superposition (CS) offers faster and smoother results but by making approximations. We investigated MC denoising techniques, which use available convolution superposition results and new noise filtering methods to guide and accelerate MC calculations. Two main approaches were developed to combine CS information with MC denoising. In the first approach, the denoising result is iteratively updated by adding the denoised residual difference between the result and the MC image. Multi-scale methods were used (wavelets or contourlets) for denoising the residual. The iterations are initialized by the CS data. In the second approach, we used a frequency splitting technique by quadrature filtering to combine low frequency components derived from MC simulations with high frequency components derived from CS components. The rationale is to take the scattering ...
Seafloor mapping and morphometric analysis of landslide scars can provide useful insights for marine geo-hazard assessment, as demonstrated by several studies performed on different geological settings. The availability of high-resolution multibeam bathymetry and long-range side scan sonar data on the submarine portions of Stromboli Volcano allow us to map and characterize the main mass-wasting features that affect, on the whole, about the 90% of its submarine extension. In particular, two main kinds of tsunamigenic landslides have been recognized and analyzed. Large-scale sector collapses (Fig. 1) are catastrophic events that mobilize 1-2 cubic kilometers of material, generating huge tsunami waves that may affect Stromboli and propagate in surrounding areas; related hazard is not very high, as they show recurrence periods of some (or more) thousand years. Conversely, medium-scale landslides are more hazardous, as they occur at higher frequency with respect to the previous events, i.e. ...
The aim of this work was to develop several strategies and software-packages for the evaluation of in-vivo-data of the human brain, which were acquired with high-resolution 1H-MRSI at 1.5 and 3 T. Several studies involving phantoms, volunteers and patients were performed. Quality assurance studies were conducted in order to evaluate the reproducibility of the applied MR-techniques at both field strengths. A qualitative comparison-study between MRSI-data from a 1.5 T clinical MR-scanner and a 3 T research MR-scanner showed the advantages of the more advanced MRSI sequences and higher field strength (3 T). A study involving patients with primary brain tumours (gliomas) was performed in cooperation with the Department of Neurosurgery (University of Erlangen-Nuremberg). The methods developed in the course of this study, such as the integration of MRS-data into a stereotactic-system, the segmentation of metabolic maps and the correlation with histopathological findings represent a package ...
Full text: Based on experience with nuclear material confiscated in Hungary from illicit trafficking activities in the nineties it has been decided that traditional gamma-spectrometry should be complemented by destructive analytical techniques. The 17/1996 (I. 31.) Korm. Governmental Decree delegated the identification, categorization and characterization tasks to the Institute of Isotopes, Budapest. Routine gamma-spectrometric methods have been further developed aiming at the i) age (production date) determination of seized samples and complete (nondismountable) uranium-bearing items (such as fresh fuel bundles and fission chambers) by HRGS technique, ii) improvement of measurement accuracy and reliability. Starting in 2005 mass spectrometry (ICP-SFMS) and scanning electron microscopy have been implemented to characterize nuclear samples in more detail and to analyze environmental samples both for isotopic and elemental composition focusing on long-lived radioactive isotopes including ...
Regional cortical thickness was evaluated using CIVET processing of 3D T1-weighted images (i) to compare the variation in cortical thickness between 33 participants with fetal alcohol spectrum disorders (FASD) aged 6-30 years (mean age 12.3 years) versus 33 age/sex/hand-matched controls, and (ii) to examine developmental changes in cortical thickness with age from children to young adults in both groups. Significant cortical thinning was found in the participants with FASD in large areas of the bilateral middle frontal lobe, pre- and post- central areas, lateral and inferior temporal and occipital lobes compared to controls. No significant cortical thickness increases were observed for the FASD group. Cortical thinning with age in a linear model was observed in both groups, but the locations were different for each group. FASD participants showed thinning with age in the left middle frontal, bilateral precentral, bilateral ...
In order to predict or to evaluate the structural reliability of a variety of nuclear components under actual changing operating conditions, it is necessary to take the detailed geometrical features of components into consideration on one hand, and thermo-mechanical loading conditions with space and time variations during the lifetime, on the other hand. This consideration leads the authors to develop a super large-scale structural analysis program based on a parallel computational FEM with a variable scale of PC cluster architecture, whose prototype system is presented in a companion paper in this Symposium. Development of the PC cluster technology is one of the most important subjects in large-scale structural simulation, reducing computer costs and thus making simulation more acceptable to the engineering community. This paper presents the developmental status of the parallel FEM solver, demonstrating computational capabilities with three dimensional effects taking into ...
Numerous mercury intrusion porosimetry (MIP) studies have been carried out to investigate the pore structure in cement-based materials. However, the standard MIP often results in an underestimation of large pores and an overestimation of small pores because of its intrinsic limitation. In this paper, an innovative MIP method is developed in order to provide a more accurate estimation of pore size distribution. The new MIP measurements are conducted following a unique mercury intrusion procedure, in which the applied pressure is increased from the minimum to the maximum by repeating pressurization-depressurization cycles instead of a continuous pressurization followed by a continuous depressurization. Accordingly, this method is called pressurization-depressurization cycling MIP (PDC-MIP). By following the PDC-MIP testing sequence, the volumes of the throat pores and the corresponding ink-bottle pores can be determined at every pore size. These values are used to calculate pore size ...
A conventional PET scanner has a 15-25 cm axial field-of-view (FOV) and images a whole body using about six bed positions. An OpenPET geometry can extend the axial FOV with a limited number of detectors. The entire whole-body PET scanner must be able to process a large amount of data effectively. In this work, we study feasibility of the fully 3D entire whole-body PET scanner using the GATE simulation. The OpenPET has 12 block detector rings with the ring diameter of 840 mm and each block detector ring consists of 48 depth-of-interaction (DOI) detectors. The OpenPET has the axial length of 895.95 mm with five parts of 58.95 mm open gaps. The OpenPET has higher single data loss than a conventional PET scanner at grouping circuits. NECR of the OpenPET decreases by single data loss. But single data loss is mitigated by separating the axially arranged detector into two parts. Also, multiple coincidences are found to be ...
Bone is a complex, highly structured, mechanically active, three-dimensional (3-D) tissue composed of cellular and matrix elements. We previously published a report on in situ collagen gelation using a rotary 3-D culture system (CG-RC system) for the construction of large tissue specimens. The objective of the current study was to evaluate the feasibility of bone tissue engineering using our CG-RC system. Osteoblasts from the calvaria of newborn Wistar rats were cultured in the CG-RC system for up to 3 wk. The engineered 3-D tissues were implanted into the backs of nude mice and calvarial round bone defects in Wistar rats. Cell metabolic activity, mineralization, and bone-related proteins were measured in vitro in the engineered 3-D tissues. Also, the in vivo histological features of the transplanted, engineered ...
1 - Description of program or function: T-HEMP3D (Transportable HEMP3D) is a derivative of the STEALTH three-dimensional thermodynamics code developed by Science Applications, Inc. Changes were made primarily in three areas: material specification, coordinate generation, and the addition of sliding surface boundary conditions. STEALTH itself is based entirely on the HEMP3D code written at LLNL. HEMP3D solves problems in solid mechanics involving dynamic plasticity and time-dependent material behavior and problems in gas dynamics. 2 - Method of solution: The equations of motion, conservation equations, and constitutive relations for stresses, strains, hydrostatic pressure, the von Mises yield condition, and artificial viscosity are solved by finite difference methods following the format of the HEMP code (NESC Abstract ...
The non-natural pyrido[2,3-d]pyrimidine nucleoside F, which pairs preferentially with guanine (G) and adenine (A) within double-helical DNA, recognizes with high selectivity AT base pairs within triple-helical...Full Text Available
The achievement of inner-shell photoionization of Zn-like Pd by means of two exploding foils is described. This resulted in the soft X-ray transition 3d94s2-3d104p at 46 A. It is shown that the photoionization of inner shell electrons in highly stripped ions can lead to X-ray transitions which may be candidates for X-ray lasers under 50 A.
The lowest excited level in Ni-like ions, 3d{sup 9}4s {sup 3}D{sub 3}, decays only via a magnetic octupole (M3) decay. They present calculated values of transition wavelengths and rates for ions with 30 {le} Z {le} 100. They have observed this line in Xe{sup 26+}, using the Livermore EBIT-I electron beam ion trap and a microcalorimeter, as well as a high-resolution flat-field grating spectrometer.
Our studies on K#beta#/K#alpha# X-ray intensity ratios of some of the technologically important 3d-transition metal compounds have been reviewed. Comparison of the experimental results with single-configuration Dirac-Fock calculations provided important information on the valence states of the transition metals in various compounds, which can be helpful in understanding the nature of bonding in the compounds. (author)
Chemical influences on the relative Ksub(..beta..)/Ksub(..cap alpha..) x-ray intensity ratio up to five per cent were found for different chemical constitutions of Cr, Mn, Fe and Cu by very precise PIXE measurements. In the discussion of these effects, screening of 3p electrons by a varying 3d valence charge, as well as polarizational effects are of importance.
Chemical influences on the relative Ksub(#nu#)/Ksub(#alpha#) x-ray intensity ratio up to five per cent were found for different chemical constitutions of Cr, Mn, Fe and Cu by very precise PIXE measurements. In the discussion of these effects, screening of 3p electrons by a varying 3d valence charge, as well as polarisational effects are of importance. (author).
We have studied the nucleation and growth processes in a chemical vapor deposition (CVD) diamond film using a tomographic electron backscattering diffraction method (3D EBSD). The approach is based on the combination of a focused ion beam (FIB) unit for serial sectioning in conjunction with high-resolution EBSD. Individual diamond grains were investigated in 3-dimensions particularly with regard to the role of twinning.
Much of the current technology on 3D-prestack depth migration is based on the Kirchhoff method and the traveltime information needed for this purpose is obtained by the ray-theory approximation. The main motivation driving these options is to reduce computations but it can also have an adverse effect on the quality of results. Experience with real data indicates that the corresponding poststack data migrated by the reverse-time method often yields superior results. Considerable computational efficiency can be obtained by employing nonuniform coarse grid spacing during the reverse-time migration. We followed this strategy for developing a parallel scheme for doing 3D- prestack depth migration. However, we worked only on a small subset of shot gathers whose determined by the Quasi-Monte Carlo method. The results were indistinguishable from those obtained by using a much larger population of uniformly ...
An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)
Heat transfer processes use fluids which are generally not pure and can react with transfer surfaces. These surfaces are subject to deposits which can be sediments harmful to heat transfer and to integrity of materials. For nuclear plant steam generators, sludge build-up accelerates secondary side corrosion by concentrating chemical species. A major safety problem involved with such a corrosion is the growing of circumferential cracks which are very difficult to detect and size with eddy current probes. With a view to understand and control this problem, it is necessary to develop a mathematical model for the prediction of sludge behavior in PWR steam generators. Based on fundamental principles, this work intends to use different models available in literature for the prediction of the phenomenon leading to the accumulation of sludge particles at the bottom (the tubesheet) of a PWR. For that, a three-dimensional simulation of magnetite particulate fouling with the finite elements code ...
The objective of this study was to explore the role of three-dimensional (3-D) rotational angiography (RA) of the inferior vena cava (IVC; 3-D CV) before filter retrieval and its impact on treatment planning compared with standard anteroposterior cavography (sCV). Thirty patients underwent sCV and 3-D CV before IVC filter retrieval. Parameters assessed were: projection of filter arms or legs beyond the caval lumen, thrombus burden within the filter and IVC, and orientation of the filter within IVC. Skin and effective radiation doses were calculated. Statistical analysis was performed using paired Student t test and nonparametric McNemar's test. Standard anteroposterior cavography detected 49 filter arms or legs projecting beyond the caval lumen in 25 patients. Three-dimensional CV demonstrated 89 filter arms or legs projecting beyond the caval lumen in 28 ...
Purpose: The purpose of this study was to observe the process of fixation in liver specimens non-invasively by means of magnetic resonance. The fixation process of several formaldehyde-containing solutions was monitored with MRI and MRS at two different temperatures. Materials and Methods: Liver specimens were conserved in aqueous fixative solutions containing formaldehyde concentrations of 0.7, 1.8, 4 and 7.2% and at different temperatures of 5 C and 20 C. MRI was performed with T1-, T2- and PD-weighted TSE sequences, a 2D FLASH-sequence with and without magnetization transfer, and a FISP 3D-sequence on a clinical 1.5 Tesla MR whole-body unit, and MRS with {sup 1}H-spectroscopic methods (STEAM-sequence) on a 3 Tesla MR whole-body unit. Results: The diffusion of formaldehyde into the tissue was best identified on PD- and T1-weighted images as a band under the liver surface with increasing thickness, penetrating especially ...
Magnetic resonance imaging (MRI) as a diagnostic imaging tool relies on the generation of magnetic fields, whereas the computerized tomography (CT) uses X-radiation. The fundamental principle of MRI is the magnetic resonance of paramagnetic atomic nuclei. These nuclei, as e.g. protons (= hydrogen nuclei), are aligned in required orientation by application of a strong magnetic field. Upon simultaneous application of an electromagnetic high-frequency field perpendicular to the axis of the basic magnetic field, and in response to periodical changing of the electromagnetic field at a given frequency, the originally aligned paramagnetic nuclei are forced into a movement similar to that of a ``whipping top``. When the resonance frequency is shut off, the nuclei return to their former, aligned positions, inducing a weak signal in a coil. The series of signals generated by multiple repetition of this process of excitation of nuclei and their return to ...
This document is a user`s manual for the Rn3D finite element code. Rn3D was developed to simulate gas flow and radon transport in variably saturated, nonisothermal porous media. The Rn3D model is applicable to a wide range of problems involving radon transport in soil because it can simulate either steady-state or transient flow and transport in one-, two- or three-dimensions (including radially symmetric two-dimensional problems). The porous materials may be heterogeneous and anisotropic. This manual describes all pertinent mathematics related to the governing, boundary, and constitutive equations of the model, as well as the development of the finite element equations used in the code. Instructions are given for constructing Rn3D input files and executing the code, as well as a description of all output files generated ...
A 3-D hydrodynamic dispersion model for tracer transport is developed and implemented into the TOUGH2 EOS3 (T2R3D) module. The model formulation incorporates a full dispersion tensor, based on a 3-D velocity field with a 3-D, irregular grid in a heterogeneous geological system. Two different weighting schemes are proposed for spatial average of 3-D velocity fields and concentration gradients to evaluate the mass flux by dispersion and diffusion of a tracer or a radionuclide. This new module of the TOUGH2 code is designed to simulate processes of tracer/radionuclide transport using an irregular, 3-D integral finite difference grid in non-isothermal, three-dimensional, multiphase, porous/fractured subsurface systems. The numerical method ...
The use and application of remote sensing data for monitoring the environmental impacts of open cast lignite mining in Eastern Germany is described. This investigation is based on the digital analysis of several Landsat-TM and ERS-1 data sets acquired from 1989 to 1994. The characteristics of the imagery enable quantitative analysis of different open cast mine features, such as waste, water bodies, change of land use, reclamation processes and estimation of vegetation cover in the affected areas. On the basis of the Maximum Likelihood Classification of Landsat Thematic Mapper (TM) data the open cast mining areas were separated into bare open cast areas and areas of less and dense vegetation. The bare open cast areas were classified with respect to type of different sediments and the vegetation was seperated into different classes according to the age of the vegetation and the density cover. Apart from these, water bodies within the mining areas were classified into ...
Initial major applications of neutron radiography (NR) to nuclear engineering were nondestructive inspections of nuclear fuel, control rods, reactor materials and some other components. Increase in the available neutron flux over 10{sup 8} n/cm{sup 2}s at the JRR-3M thermal neutron radiography facility (TNRF) in 1991 has expanded the application field to the dynamic but clear imaging of moving objects and fluid phenomena. The JRR-3M TNRF is facilitated with three major imaging systems, being characterized by spatial and/or temporal resolutions: 1. Static neutron radiography (SNR), 2. real-time neutron radiography (RNR) with an imaging rate of 30 frames/s and 3. High-frame-rate neutron radiography (HFRNR). SNR has been used for three-dimensional visualization of air-water two-phase flows in a simulated rod bundle. Three-dimensional computed tomography clearly illustrated average void fraction distributions around tie ...
The surface losses in the drift-tube linac (DTL) tanks 3 and 4 of the LANSCE linear accelerator are calculated using 3-D electromagnetic modeling with the CST MicroWave Studio (MWS). The results are used to provide more realistic power estimates for the 201.25MHz RF upgrade design within the LANSCE-R project. We compared 3-D MWS results with those from traditional 2-D Superfish computations for DTL cells and their simplified models and found differences on the level of a few percent. The differences are traced to a 3-D effect consisting in a redistribution of the surface currents on the drift tubes (DT) produced by the DT stem. The dependence of MWS results on the mesh size used in computations is also discussed.
Objectives To investigate the feasibility and reproducibility of measurements of nasal bone length using a three-dimensional (3D) ultrasound in the first trimester. Methods In a prospective study, 118 consecutive pregnant women attending for Down syndrome screening at 11-13 + 6 weeks were recruited. They had successful fetal nasal bone measurement by two-dimensional (2D) ultrasound by four operators. Three-dimensional volumes were recorded in the mid-sagittal plane of fetal profile by the fifth operator and examined using multiplanar techniques. Another independent investigator randomly compared his measurements with one of the four operators. Results In the subsequent 3D examination, the nasal bone length could be examined in 94 cases (79.7%). The mean difference between the 2D and 3D mea...
A three-dimensional (3D) thermal-hydraulic model and a numerical procedure for the simulation and analysis of a steady-state, as well as transient operation of nuclear power plant components are presented. A two-fluid approach is applied to modelling of two-phase flow. Thermal-hydraulics of a horizontal steam generator in the WWER 1000 nuclear power plant has been simulated at the full load, steady-state operation. A comparison of the numerical results with data measured at the NPP Novovoronjezh shows good agreement. 3D numerical results can be used in plant design or retrofitting, in nuclear power plant operation and safety analysis and as improvement of existing one-dimensional thermal-hydraulics models of the horizontal steam generator which are assessed by system codes used for the nuclear power plant safety analyses. (author)
A three-dimensional (3D) thermal-hydraulic model and a numerical procedure for the simulation and analysis of a steady-state, as well as transient operation of nuclear power plant components are presented. A two-fluid approach is applied to modelling of two-phase flow. Thermal-hydraulics of a horizontal steam generator in the WWER 1000 nuclear power plant has been simulated at the full load, steady-state operation. A comparison of the numerical results with data measured at the NPP Novovoronjezh shows good agreement. 3D numerical results can be used in plant design or retrofitting, in nuclear power plant operation and safety analysis and as improvement of existing one-dimensional thermal-hydraulics models of the horizontal steam generator which are assessed by system codes used for the nuclear power plant safety analyses. (author)
This paper describes a comprehensive model of wastewater treatment in secondary facultative ponds, which combines 3D hydrodynamics with a mechanistic water quality model. The hydrodynamics are based on the Navier-Stokes equation for incompressible fluids under shallow water and Boussinesq assumptions capturing the flow dynamics along length, breadth and depth of the pond. The water quality sub model is based on the Activated Sludge Model (ASM) concept, describing COD and nutrient removal as function of bacterial growth following Monod kinetics, except for Escherichia coli removal, which was modelled as first order decay. The model was implemented in the Delft3D software and was used to evaluate the effect of wind and the addition of baffles on the water flow pattern, temperature profiles i...
... Title : Optical Images Due to Lenses and Mirrors. ... Abstract : The properties of real and virtual images formed by lenses and mirrors are reviewed. ...
The investigation of interfaces between thin organic films and metal surfaces is a field of highest interest because it represents the basis for future applications of organic electronic devices. In this context, phtalocyanines are of particular interest since repulsive intermolecular interaction was found recently for this group of organic molecules. Tin(II)-phtalocyanine (SnPc) is non-planar and can adsorb in two different geometries: with the Sn atom pointing downwards (Sn down) or upwards (Sn up). In our group different Pc molecules have previously been studied using several experimental techniques like SPA-LEED or XSW. Here we present STM studies of SnPc on Ag(111), taken at different coverages and temperatures, and discuss the results in the context of our previous findings. At low coverages the formation of chains can be observed for Sn down molecules while Sn up molecules tend to stay separated. This originates from a strong interaction with the substrate which leads to a ...
Biodiesel made from vegetable oil is among the most desirable of renewable energy sources because it can be a substitute for diesel oil. However, biodiesel from soybean or corn can be confronted with a food crisis. Microalgae is a new biodiesel source which contains high oil lipids with a high growth rate, and which also offers value-added products from the residue, such as cosmetics, health functional food or pharmaceuticals. Microalgae are best cultivated in photo-bioreactors (PBRs) where light, nutrients, carbon dioxide and temperature can be controlled. Despite the current availability of PBRs, only a few can be practically used for mass production. Computational fluid dynamics (CFD) was used in this study to design an optimum bubble-column PBR for mass production of microalgae. Multi-phase models including bubble movement, meshes and time step independent tests were considered to develop the 3-dimensional CFD model. Particle Image Velocimetry (PIV) tests were ...
We present the results of an isophotal shape analysis of three samples of galaxies in the Coma cluster. Quantitative morphology, together with structural and photometric parameters, is given for each galaxy. Special emphasis has been placed on the detailed classification of early-type galaxies. The three samples are: i) a sample of 97 early-type galaxies brighter than m_B = 17.00 falling within one degree from the center of the Coma cluster; these galaxies were observed with CCD cameras, mostly in good to excellent resolution conditions; ii) a magnitude complete sample of 107 galaxies of all morphological types down to m_B = 17.00 falling in a circular region of 50 arcmin diameter, slightly offcentered to the North-West of the cluster center; the images for this and the next sample come from digitized photographic plates; iii) a complete comparison sample of 26 galaxies of all morphological types down to m_R = 16.05 (or m_B \\simeq 17.5), also ...
Hepatobiliary scintigraphy is the only non-invasive technique providing real-time assessment of hepatocytes function and bile progression from the liver to the intestine; for this reason it is of great importance in the study of jaundice and many other disorders of the liver and the biliary tract in children. Ultrasonography is the initial method of evaluating the intra- and extrahepatic bile ducts dilatation: the differential diagnosis between biliary atresia and neonatal hepatitis cannot however be done without hepatobiliary scintigraphy. Cystic fibrosis patients also require hepatobiliary scintigraphy; liver and biliary tract disease can really occur independently of the underlying disease severity and the presence of steatorrhoea. Hepatobiliary imaging in children who have undergone liver transplantation is of major importance; it can assess vascularity, parenchymal function biliary drainage, possible presence of a bile leak and obstruction; it has very good ...
A Digital X-ray imaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS method): A simple ...
The Compton backscatter technique has been applied to lap-joint in aircraft structure in order to determine mass loss due to exfoliative corrosion of the aluminum alloy sheet skin. The mass loss of each layer has been estimated from Compton backscatter A-scan including the aluminum sheet, the corrosion layer, and the sealant. A Compton backscattering imaging system has been also developed to obtain a cross-sectional profile of corroded lap-splices of aging aircraft using a specially designed slit-type camera. The camera is to focus on a small scattering volume inside the material from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the layered structure is scanned by moving the scattering volume through the thickness direction of the specimen. The theoretical model of the Compton scattering based on Boltzmann transport theory is presented for ...
Mammography has emerged as a reliable non-invasive technique for the early detection of breast cancer--the second leading cause of cancer-related mortality among American women. The radiographic appearance of the female breast consists of radiolucent (dark) regions due to fat and radiodense (light) regions due to connective and epithelial tissue. The amount of radiodense tissue can be used as a marker for predicting breast cancer risk. This paper presents the development of an algorithm for estimating the percentage of radiodense tissue in a digitized mammogram. The technique involves determining a dynamic threshold for segmenting radiodense indications in mammograms. Both the mammographic image and the threshold are modeled as Gaussian random variables. This work is intended to support a concurrent study at the Fox Chase Cancer Center (FCCC) exploring the association between dietary patterns and breast cancer risk. Mammograms have been obtained from an existing ...
Jun 10, 2011 ... Subsonic flow past a semi-infinite flat plate is modeled at Reynolds number 6 ..... data is taken from Cook, McDonald, and Firmin, AGARD-AR-138, 1979, p. ...... too large a time-averaged separation bubble behind the hump. ...
Using the complete genome of Plasmodium falciparum 3D7 which has 14 chromosomes as an example, we have examined the distribution functions for the amount of C or G and A or T consecutively...Full Text Available
A robust technique for determining the principal axes of a 3D shape represented by a point set, possibly with noise, is presented. We use techniques from robust statistics to guide the classical...Full Text Available
The development of three-dimensional (3D) biomimetic scaffolds which provide an optimal environment for cells adhesion, proliferation and differentiation, and guide new tissue formation has...Full Text Available
We propose the Particle Swarm Optimization (PSO) as an alternative method for locating periodic orbits in a three--dimensional (3D) model of barred galaxies. We develop an appropriate scheme that transforms the problem of finding periodic orbits into the problem of detecting global minimizers of a function, which is defined on the Poincar\\'{e} Surface of Section (PSS) of the Hamiltonian system. By combining the PSO method with deflection techniques, we succeeded in tracing systematically several periodic orbits of the system. The method succeeded in tracing the initial conditions of periodic orbits in cases where Newton iterative techniques had difficulties. In particular, we found families of 2D and 3D periodic orbits associated with the inner 8:1 to 12:1 resonances, between the radial 4:1 and corotation resonances of our 3D Ferrers bar model. The main ...
Estimates of global warming during the mid-Piacenzian Age of the Pliocene Epoch suggest temperatures were 2 degrees C greater than today. ... million years approaches this level of warming. PRISM/Global Warmin...
There has been a controversy as to whether or not the non-pathological flat foot and high-arched foot have an effect on human walking activities. The 3D foot scanning system was employed to obtain static...Full Text Available
The relationships between muscle tensions, jaw motions, bite and joint forces, and craniofacial morphology are not fully understood. Three-dimensional (3-D) computer models are able to combine anatomical...Full Text Available
Metacad is a collection of routines which creates a randomly accessible data structure from Applicon's APPLE-3D data format and supplies a logical method for manipulation of the data structure by a CAD application program.
Approximately 62,000 lbs Fuel Load: 58,000 lbs. Type Fuel: JP4, JP5, JP8, JET A, JET A-1, JET B Standard Fuel Burn: 4500 - 6000 lbs/hr depending on altitude and airspeed Maximum...
Experiments are performed to investigate the single-phase flow and flow-boiling heat transfer augmentation in 3D internally finned and micro-finned helical tubes. The tests for single-phase flow heat transfer augmentation are carried out in helical tubes with a curvature of 0.0663 and a length of 1.15 m, and the examined range of the Reynolds number varies from 1000 to 8500. Within the applied range of Reynolds number, compared with the smooth helical tube, the average heat transfer augmentation ratio for the two finned tubes is 71% and 103%, but associated with a flow resistance increase of 90% and 140%, respectively. A higher fin height gives a higher heat transfer rate and a larger friction flow resistance. The tests for flow-boiling heat transfer are carried out in 3D internally micro-finned helical tube with a curvature of 0.0605 and a length of 0.668 m. Compared with that in the smooth helical ...
A compact dedicated 3D breast SPECT-CT (mammotomography) system is currently under development. In its initial prototype, the cone-beam CT sub-system is restricted to a fixed-tilt circular rotation...Full Text Available
Electrospun nanofibers composed of biodegradable polymers are attractive candidates for cell culture scaffolds in tissue engineering. Their fine-meshed structures, resembling natural extracellular matrices, effectively interact with cell surfaces and promote cell proliferation. The application of electrospinning, however, is limited to two-dimensional (2D) or single tube-like scaffolds, and the fabrication of arbitrary three-dimensional (3D) scaffolds from electrospun nanofibers is still very difficult due to the fibers' continuous and entangled form. To address this issue, in this paper, we describe the use of phase-separation-assisted electrospray and electrostatic focusing to perform continuous direct 3D patterning of nanofibrous microcapsules of biodegradable polylactic acid (PLA). These microcapsules exhibit fiber-particle duality because they are composed of nanofibers suitable for cell attachment ...
The objective was to study the interaction of a side jet with the incoming supersonic flow and hypersonic flow. Qualitatively same Cp trends have been obtained as found experimentally. Also in aerodynamic coefficients side jet interaction results in additional pitching moment which is because of the high pressure region in upstream of the jet and a low pressure region in the downstream of the jet. Also jet interaction results in the rise in the lift coefficient. Whereas in the incidence case, simulation has been performed for the hypersonic flows over a biconic body with supersonic lateral jet at Mach 9.7 and incidence of 0"o to incidence of -12"o and 12"o. The results obtained were compared with the experimental and CFD code CFL3D results. PAK-3D over predicts the surface pressure as compared to the CFL3D and experimental results, whereas the qualitative trends ...
Neutron semiconductor detectors for neutron counting and neutron radiography have an increasing importance. Simple silicon neutron detectors are combination of a planar diode with a layer of an appropriate neutron converter such as 6LiF. These devices have limited detection efficiency of not more than 5%. The detection efficiency can be increased by creating a 3D microstructure of dips, trenches or pores in the detector and filling it with a neutron converter. The first results related to the development of such devices are presented. Silicon detectors were fabricated with pyramidal dips on the surface covered with 6LiF and then irradiated by thermal neutrons. Pulse height spectra of the energy deposited in the sensitive volume were compared with simulations. The detection efficiency of these devices was about 6.3%. Samples with different column sizes were fabricated to study the electrical properties of ...
A new 3D model is developed to simulate the self-oscillation of the elongated vocal folds. This model allows for large deformation and longitudinal displacement. The displacement boundary condition...Full Text Available
This paper presents a new methodology to create realistic 3D microstructures of polycrystals. The virtual microstructures are based on statistical data describing the morphological and crystallographic textures of a sample, obtained from an EBSD analysis. In addition, the methodology can reproduce the observed surface on top of the simulated microstructure. This feature allows finite element calculations on these virtual aggregates to be compared to experimental results of mechanical tests. Such a comparison leads to the identification of the mechanical parameters of constitutive laws, such as critical resolved shear stress and strain hardening, using an optimization algorithm. Two materials were simulated in this study: TiAl and grade 702 zirconium. The first one presents twins inside the microstructure and the second one has an anisotropic texture. Based on 2D simulations, the important parameters necessary to describe a microstructure were ...
Developing in vitro engineered hepatic tissues that exhibit stable phenotype is a major challenge in the field of hepatic tissue engineering. However, the rapid dedifferentiation of...Full Text Available
Quantitative I-131 labelled Peanut lectin (I-131-PNA) renal clearance was determined in dogs before and after a 5 day single cycle cis-platinum chemotherapy regimen (0.5mg/Kg/day). Results were statistically compared with E.R.P.F. (I-131-Hippuran), G.F.R. (Tc-99m-DTPA), and serum biochemistry and correlated with histopathology. I-131-PNA clearance was significantly reduced in all dogs 5 days after cessation of cis-platinum treatment (mean #DELTA#S% = 71.3%) and similar reductions in the gamma camera derived renogram peak were demonstrated (mean #DELTA#S% = 65.8%). E.R.P.F. was noted to drop by a minor degree (mean #DELTA#S% = 20.9%) post treatment. G.F.R. was diminished (mean #DELTA#S% = 46.6%) and serum creatinine elevated (mean #DELTA#S% = 42.7%) in all dogs compared to their pretreatment values. Histopathology demonstrated variable degrees of tubular toxicity ranging from mild to severe. The degree of change of the I-131-PNA values was significantly greater than ...
Diseases of the mandible affect the soft tissues aside from the osseous manifestation. This can be shown clearly and in great detail by magnetic resonance imaging (MRI). MRI is the gold standard in the diagnostic evaluation of any internal derangement of the temporomandibular joint. Dental MRI requires high resolution techniques and in some cases also intravenous administration of contrast material. These techniques allow delineation of the neurovascular bundle. In the past few years new indications were formulated, for example, the evaluation of the integrity of the inferior alveolar nerve in trauma and in radicular cysts. New quantitative methods now enable insights into the pathophysiology. The objective of this review is to communicate accepted indications for MRI of the mandible and to present innovative applications. (orig.) [German] Mandibulaere Erkrankungen beteiligen neben dem Knochen Weichteilstrukturen, die sich mit der MRT klar und ...
The evaluation of biological markers is recognized as necessary to the future of toxicology, epidemiology, and quantitative risk assessment. For biological markers to become widely accepted, their validity...Full Text Available
Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A computer controlled data acquisition system and a water tank where used ...
The measurement of K(alpha)/K(beta) X-ray intensity ratio indicates the excitation process and the chemical state of the atom examined. Theoretical considerations on the origin of this property are presented. The difference of these ratios following photoionization and electron capture are calculated by a computer code generating transition matrix elements. The theoretical assumptions involved in the codes are tested by comparing the experimental and calculated data concerning 3d transition element atoms. (D.Gy.).
Twenty-seven patients with symptoms or clinical findings suggesting joint or bone disorders of the anterior chest wall (ACW) were evaluated by spiral CT with 3-dimensional (3-D) and multiplanar reconstructions. Preceding conventional ACW tomography was performed in 10 patients. ACW joint and bone changes were visualized more adequately by coronal 2-D reconstructions based on spiral CT than by conventional tomography. In addition, nonossified costal cartilages and soft tissue lesions were demonstrated. 3-D reconstructions sometimes added information, especially in patients with fracture and dislocation. (orig.).
The paper presents the integration of the SIMBAD space charge module in the UAL framework. SIMBAD is a Particle-in-Cell (PIC) code. Its 3-D Parallel approach features an optimized load balancing scheme based on a genetic algorithm. The UAL framework enhances the SIMBAD standalone version with the interactive ROOT-based analysis environment and an open catalog of accelerator algorithms. The composite package addresses complex high intensity beam dynamics and has been developed as part of the FAIR SIS 100 project.
The term biological motion is often used by researchers studying the patterns of movement generated by living forms and in sports. We studied a pattern recognition system of motion in sport using biological motion data. Biological motion data are acquired using a 3D motion capture system. However, 3D motion capture systems are very expensive. In this article, a biological motion capture system was built using acceleration sensors. Our proposed system uses the technique of Gaussian fitting and regression analysis. We tested our proposed system in pattern recognition of outdoor tennis and its evaluations.
The electronic structure of octahedral metal atom clusters Me/sub 6/ of 3d, 4d, and 5d transition metal atoms (V, Cr; Nb, Mo; Ta, W) has been calculated applying two different quantum-chemical approximation methods (Extended Hueckel (EH) method; SW-Xsub(alpha) method). Equilibrium structures, energy level schemes, Fermi energies and band widths as well as densities of states of clusters are discussed in detail.
A series of pyrrolo[2,3-d]pyrimidine-2,4-diones and intermediates was tested for anticonvulsant activity in mice. Eleven of the 15 compounds possessed anticonvulsant activity against pentylenetetrazol-induced convulsions. One compound afforded more anticonvulsant protection against pentylenetetrazol than did trimethadione (67 and 50%, respectively). A suspension of this compound was found to be as effective as a solution in producing anticonvulsant activity. The results suggest that the nitrile analogs were more potent compared to the carbamyl analog due to higher lipid solubility. PMID:7373552
Full text: A semiempirical algorithm for absorbed dose calculation at off-axis points in irregular beams was implemented. It is well known that semiempirical methods are very useful because of their easy implementation and its helpfulness in dose calculation in the clinic. These methods can be used as independent tools for dosimetric calculation in many applications of quality assurance. However, the applicability of such methods has some limitations, even in homogeneous media, specially at off axis points, near beam fringes or outside the beam. Only methods derived from tissue-air-ratio (TAR) or scatter-maximum-ratio (SMR) have been devised for those situations, many years ago. Despite there have been improvements for these manual methods, like the Sc-Sp ones, no attempt has been made to extend their usage at off axis points. In this work, a semiempirical formalism was introduced, based on the works of Venselaar et al. (1999) and Sanz et al. (2004), aimed to the Sc-Sp separation. This ...
Surgical resection is the only curative treatment strategy for intrahepatic cholangiocarcinoma (CC). Therefore, accurate staging is essential for appropriate management of patients with CC. We assessed the usefulness of 2-["1"8F]fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) in the staging of CC. We undertook a retrospective review of FDG PET images in 21 patients (10 female, 11 male; mean age 57 years) diagnosed with CC. Ten patients had hilar CC and 11, peripheral CC. Patients underwent abdominal magnetic resonance imaging (MRI) (n=20) and computed tomography (CT) (n=12) for the evaluation of primary tumours, and chest radiography and whole-body bone scintigraphy for work-up of distant metastases. For semi-quantitative analysis, the maximum voxel standardised uptake value (SUV_m_a_x) was obtained from the primary tumour. All peripheral CCs showed intensely increased FDG uptake, and some demonstrated ...
The central benzodiazepine receptor tracer [N-methyl-"1"1C]iomazenil (Ro 16-0154) was synthesized by alkylation of the desmethyl precursor noriomazenil with ["1"1C]methyl iodide. The ["1"1C]CH_3I (prepared by reduction of ["1"1C]CO_2 with LiAlH_4 followed by reaction with HI) was reacted with noriomazenil inN,N -dimethylformamide and Bu_4N"+OH"- for 1 min at 80 deg. C and purified by HPLC (C_1_8, 34% CH_3CN/H_2O, 7 mL/min). The product was obtained with synthesis time 35 #+-# 5 min (mean #+-# SD, n = 7), radiochemical yield (EOB) 36 #+-# 16%, radiochemical purity 99 #+-# 1%, and specific activity 5100 #+-# 2800 mCi/#mu#mol. Absorbed radiation doses were calculated from previously acquired human biodistribution data. The urinary bladder wall received the highest dose (0.099 mGy/MBq) for 4.8 h voiding interval and the effective dose equivalent was 0.015 mSv/MBq. After i.v. injection of ["1"1C]iomazenil in an adult baboon or healthy human volunteer, radioactivity accumulated in the cortex ...
We examined the abnormalities of regional cerebral blood flow(rCBF) in children with attention deficit hyperactivity disorder(ADHD) without comorbidity using statistical parametric mapping(SPM) method. We used the patients with not compatible to DSM-IV diagnostic criteria of ADHD and normal rCBF pattern in visual analysis as normal control children. Tc-99m ECD brain SPECT was performed on 75 patients (M:F=64:11, 10.0{+-}2.5y) with the DSM-IV diagnostic criteria of ADHD and 13 normal control children (M:F=9:4, 10.3{+-}4.1y). Using SPM method, we compared patient group's SPECT images with those of 13 control subjects and measured the extent of the area with significant hypoperfusion(p<0.01) in predefined 34 cerebral regions. Only on area of left temporal lobe showed significant hypoperfusion in ADHD patients without comorbidity (n=75) compared with control subjects(n=13). (n=75, p<0.01, extent threshold=16). rCBF of left temporal area was ...
High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions can be quantitatively evaluated thermoluminescent dosimeter (TLD) chips with a dimension of 1/8 and film dosimetry with a spatial resolution of <1 mm used to measure the radiation ...
Sixty-three subjects, aged 6 months to 16 years, who were enrolled in a prospective, fully blinded, randomized parallel-group phase III clinical trial, received 0.1 mmol/kg doses of either Gd-BOPTA (n=29) or Gd-DTPA (n=34). The MR images were acquired before and within 10 min of contrast agent injection. The primary objective was to compare the difference from pre-dose to post-dose lesion visualization between Gd-BOPTA and Gd-DTPA. Lesion visualization was determined as the sum of individual scores for three criteria of lesion morphological characteristics (lesion border delineation, internal morphology, and contrast enhancement), each assessed qualitatively using 4-point scales. Quantitative evaluation compared changes in lesion-to-background (LBR) and contrast-to-noise (CNR) ratios and per cent enhancement. Monitoring for adverse events and evaluation of vital signs and laboratory values was performed. Pre-dose to post-dose changes in lesion ...
Image enhancement is of great importance in medical imaging where image resolution remains a crucial point in many image analysis algorithms. In this paper, we investigate brain hallucination...Full Text Available
Purpose: To assess the new method of 3-dimensional echocardiography in comparison to the 'gold standard' MRI as to its ability to calculate left ventricular volumes in patients with congenital heart disease. Materials and methods: Eighteen patients between the ages of 3.9 to 37.3 years (mean: 12.8{+-}9.7) with a geometrically abnormal left ventricle were examined using a 1.5 T scanner with a fast gradient-echo sequence (TR=14 ms, TE=2.6-2.9 ms, FOV=300-400 mm, flip angle=20 , matrix=128:256, slice thickness=5 mm, retrospective gating) in multislice-multiphase technique. Transthoracic 3D-echocardiography was performed with a 3.5 MHz transducer and a Tomtec {sup trademark} (Munich, Germany) system for 3D reconstruction. Results: Volume calculation was possible in all patients with 3D-echocardiography, but the muscle mass calculation only ...
Wind River Resources Corporation (WRRC) received a DOE grant in support of its proposal to acquire, process and interpret fifteen square miles of high-quality 3-D seismic data on non-allotted trust lands of the Uintah and Ouray (Ute) Indian Reservation, northeastern Utah, in 2000. Subsequent to receiving notice that its proposal would be funded, WRRC was able to add ten square miles of adjacent state and federal mineral acreage underlying tribal surface lands by arrangement with the operator of the Flat Rock Field. The twenty-five square mile 3-D seismic survey was conducted during the fall of 2000. The data were processed through the winter of 2000-2001, and initial interpretation took place during the spring of 2001. The initial interpretation identified multiple attractive drilling prospects, two of which were staked and permitted during the summer of 2001. The two initial wells were drilled in ...
K{beta}-to-K{alpha} X-ray intensity ratios of Ti, Cr, Fe and Co in pure metals and in Cr{sub 0.26}Fe{sub 0.74}, Cr{sub 0.80}Co{sub 0.20} and Ti{sub 0.80}Cr{sub 0.20} alloys have been measured following excitation by 59.54 keV {gamma}-rays from a 7400 MBq (200 mCi) {sup 241}Am point-source. The valence electronic structure of Ti, Cr, Fe and Co in the samples have been evaluated by the comparison of the measured K{beta}-to-K{alpha} intensity ratios with the results of multiconfiguration Dirac-Fock calculations performed for various electronic configurations of these metals. The 3d-electron populations obtained for pure metallic Ti, Cr, Fe and Co agree well with the results of band structure calculations of Papaconstantopoulos (Handbook of band structure of elemental solids, Plenum Press, New York, 1986). Our analysis indicates significant increase of 3d-electron population of Ti, Cr and Fe in the alloys ...
K#beta#-to-K#alpha# X-ray intensity ratios of Ti, Cr, Fe and Co in pure metals and in Cr_0_._2_6Fe_0_._7_4, Cr_0_._8_0Co_0_._2_0 and Ti_0_._8_0Cr_0_._2_0 alloys have been measured following excitation by 59.54 keV #gamma#-rays from a 7400 MBq (200 mCi) "2"4"1Am point-source. The valence electronic structure of Ti, Cr, Fe and Co in the samples have been evaluated by the comparison of the measured K#beta#-to-K#alpha# intensity ratios with the results of multiconfiguration Dirac-Fock calculations performed for various electronic configurations of these metals. The 3d-electron populations obtained for pure metallic Ti, Cr, Fe and Co agree well with the results of band structure calculations of Papaconstantopoulos (Handbook of band structure of elemental solids, Plenum Press, New York, 1986). Our analysis indicates significant increase of 3d-electron population of Ti, Cr and Fe in the alloys with respect to ...
The total and state-specific electron-ion recombination rate coefficients are obtained for FeI. The calculations are carried out using a new ab initio method that incorporates both the radiative and the dielectronic recombination processes in an unified and self-consistent manner. The computations employ the close coupling approximation and the R-matrix method from atomic collision theory. A 52 state close coupling eigenfunction expansion dominated by the states of the ground 3d{sup 6}4s and excited 3d{sup 7}, 3d{sup 6}4p, 3d{sup 5}4s{sup 2}, and 3d{sup 5}4s4p configurations of FeII are used in the present calculations. The important electron correlation and radiation damping effects are included via explicit coupling of autoionization and radiative channels. This is the first ...
The experimental has been performed with a view to studying complete and incomplete fusion in "1"4N + "1"6"3D_y system below 7 MeV/nucleon. The excitation functions for several reactions have been measured using the activation technique and compared with the theoretical predictions based on statistical models. The codes ALICE-91 and CASCADE used earlier for the analysis of excitation functions in case of "1"2C + "1"6"5H_0 system have been used here also with the same set of input parameters. It has been observed that the theoretical calculations do not match with the experimental excitation functions well but the overall shape of the excitation function is reproduced satisfactorily. The composite nucleus ("1"7"7T_a) formed in this ("1"4N + "1"6"3D_y) case is the same as the one formed in "1"2C + "1"6"5H_0 system studied earlier. Measured excitation functions for the same decay channels in the two cases ...
Because of questions regarding current density and inductance estimates of the Atlas oil transmission line in the region where the vertical plates connect to the disk line, calculations using the 3D FE program Flux3d were initiated. Flux3d inductance values are nearly that estimated by D. Scudder. Calculations for three base designs of E. Ballard and D. Pierce were completed where several variations for each base design were used to determine the important parameters affecting inductance and to check inductance consistency. Flux3d showed for the first base design a very high current density of 36MA/m at the connection between the vertical and horizontal ground plates resulting in a magnetic pressure of 120 kpsi. The second base design modified this connection to reduce the current density to 20MA/m and 36 kpsi and for ...
3-D depth migration is one of the most active areas of research and development and it has been approached from different angles. An accurate algorithm which works in the space-frequency domain was introduced by Blacquiere et al. (1989). Unfortunately, it is computationally very expensive and not suitable for solving real-life 3-D migration problems. This led to the development of an alternative scheme (hale, 1990) which sacrifices some accuracy but is much more efficient. It is commonly referred to as the Hale-McClellan method. An alternative procedure known as reverse-time migration works in the space-time domain. It is based on the full wave equation and yields by far the most accurate results, but it requires extremely large computer resources. However, a series of new developments (Mufti et al, 1996) have made this algorithm a very practical tool even for migrating large exploration-scale ...
Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...
Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...
Background/Objectives:Imaging technology is an important part of the diagnosis and management of spinal trauma. Indications and findings in post-traumatic imaging of the vertebral...Full Text Available
performs Gaussian pyramid operation on an image performs expand pyramid operation on an image mosaic two images using 'reduce' and 'expand' pyramid ...
This report describes the design of, and image reconstruction capacity of a Hadamard Raman Microscopic imager. Microscopy of benzoic acid and graphite electrodes, as well as electrophoretic blotting, are described. (CBS)
Kbeta-to-Kalpha X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of Ti(x)Ni(1-x) (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi (109)Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured Kbeta-to-Kalpha X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other element and/or the ...
K?-to-K? X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of TixNi1-x (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi 109Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured K?-to-K? X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other element and/or the rearrangement of ...
Power system stabilizers (PSSs) are used to enhance damping of power system oscillations through excitation control of synchronous generator. The objective of the PSS is to generate a stabilizing signal, which produces a damping torque component on the generator shaft. Conventional PSSs are designed with the phase compensation technique in the frequency domain and include the lead-lag blocks whose parameters are determined according to a linearized power system model. The performance of conventional PSSs (CPSSs) depends upon the generator operating point and the system parameters, but a reasonable level of robustness can be achieved depending on the tuning method. This paper presents a new three-dimensional PSS (3D PSS), which uses rotor speed deviation, rotor acceleration and load angle deviation as input signals. The 3D PSS attempts to return the generator to the state-space origin, based on the ...
The 3-D model program was developed to apply a mise-a-la-masse method to linear current sources with optional shapes. Mise-a-la-masse method is a bipolar mapping survey method using current sources installed in wells, and recently has been widely used for direct exploration of geothermal reservoirs. This method is also used for monitoring underground fluid as electrode arrangement of fluid flow tomography for surveying underground fluid (geothermal fluid, underground water, petroleum). In the geothermal reservoir exploration, the casing pipes of wells are used as linear current sources, and measured data are processed as those based on vertical current source. In the largely inclined well, the inclination of current sources should be considered. The 3-D modeling program was developed by difference calculus using the theoretical potential equation and apparent resistivity based on linear current sources ...
Finite element method is one of the bases for numerical solutions to engineering problems. Complex engineering problems using finite element analysis typically imply excessively large computational time. Parallel supercomputers have the potential for significantly increasing calculation speeds in order to meet these computational requirements. This paper predicts parallel NIKE3D performance on the Kendall Square Research (KSR1) system. The first part of the prediction is based on the implementation of parallel Cholesky (U{sup T}DU) matrix decomposition algorithm through actual computations on the KSRI multiprocessor system, with 64 processors, at Oak Ridge National Laboratory. The other predictions are based on actual computations for parallel element matrix generation, parallel global stiffness matrix assembly, and parallel forward/backward substitution on the BBN TC2000 multiprocessor system at Lawrence Livermore National Laboratory. The ...
Aims: Serotonin (5-hydroxytryptamine 3; 5-HT3) receptors are involved in chemotherapy-induced nausea and vomiting (CINV), and 5-HT3 antagonists are part of the `gold standard' antiemetic treatment during chemotherapy. We investigated the correlation of common variants in 5-HT3 receptor subunit genes with the occurrence of CINV. Materials & methods: A total of 110 previously characterized chemotherapy-naive women with primary breast cancer treated with anthracycline-containing chemotherapy served as a study group for mutational analysis by direct sequencing. Eight common SNPs in the 5-HT3 receptor genes, HTR3A, HTR3B, HTR3D and HTR3E, were selected for association analysis. Results: A nonsynonymous variant in HTR3D, p.G36A (rs6443930), was found to be over-represented in nonresponders, assu...
With the objective to improve the reactor physics calculation on a 2D and 3D nuclear reactor via the Diffusion Equation, an adaptive automatic finite element remeshing method, based on the elementary area (2D) or volume (3D) constraints, has been developed. The adaptive remeshing technique, guided by a posteriori error estimator, makes use of two external mesh generator programs: Triangle and TetGen. The use of these free external finite element mesh generators and an adaptive remeshing technique based on the current field continuity show that they are powerful tools to improve the neutron flux distribution calculation and by consequence the power solution of the reactor core even though they have a minor influence on the critical coefficient of the calculated reactor core examples. Two numerical examples are presented: the 2D IAEA reactor core numerical benchmark and the ...
(Abridged) We use 3D SPH calculations with higher resolution, as well as with more realistic viscosity and sound-speed prescriptions than previous work to examine the eccentric instability which underlies the superhump phenomenon in semi-detached binaries. We illustrate the importance of the two-armed spiral mode in the generation of superhumps. Differential motions in the fluid disc cause converging flows which lead to strong spiral shocks once each superhump cycle. The dissipation associated with these shocks powers the superhump. We compare 2D and 3D results, and conclude that 3D simulations are necessary to faithfully simulate the disc dynamics. We ran our simulations for unprecedented durations, so that an eccentric equilibrium is established except at high mass ratios where the growth rate of the instability is very low. Our improved simulations give a ...
The Computational Fluid Dynamics(CFD) study was conducted to assess the new design concept introduced to solve the issues on the flow deviation between SG cassettes and the supporting structure design of the flow distributing plate subjected to the flow induced vibration. Flow field from MCP to the bottom of SG was modeled for 2-dimensional(2D) CFD analysis and then sensitivity analysis on major design parameters was conducted using commercial CFD code, Fluent. The cases for detailed 3D analysis were selected based on the result of 2D analysis and the detailed 3-dimensional(3D) analysis was conducted for these selected cases using Fluent code. Flow field was modeled by RNG model and wall function, 2nd upwind scheme, porous model, structured or hybrid grid. The analysis result shows that the maximum deviation of flow distribution between SG cassettes was reduced upto about 0.1% and the pressure loss from ...
Analytical methods considering 3-D resistivity distribution, in particular, finite element method (FEM) were studied to improve the reliability of electromagnetic exploration. Integral equation, difference calculus, FEM and hybrid method are generally used as computational 3-D modeling method. FEM is widely used in various fields because FEM can easily handle complicated shapes and boundaries. However, in electromagnetic method, the assumption of continuous electric field is pointed out as important problem. The normal (orthogonal) component of current density should be continuous at the boundary between media with different conductivities, while this means that the normal component of electric field is discontinuous. In FEM, this means that current channeling is not properly considered, resulting in poor accuracy. Unless this problem is solved, FEM modeling is not practical. As one of the solutions, it ...
Techniques for reducing computation time in 3D photon dose calculations are addressed with specific emphasis given to the convolution/superposition approach. A single polyenergetic superposition model calculating absorbed dose per incident photon fluence (Gy cm"2) was developed in terms of TERMA and a total energy deposition kernel (a total point spread function). A novel approach was devised for reducing calculation time. The method, named the CF method, was based on the use of a conventional, fast model (here a modified power-law method was used) for the generation of 3D dose distributions on a fine dose matrix. Superposition calculations were carried out on a coarse matrix and calculation speed was increased simply by reducing the number of calculations. A set of correction factors was derived on the coarse grid from the ratio of the dose values from superposition to those from the conventional ...
International Thermonuclear Experimental Reactor (ITER) project is the international collaboration one for the commercialization of nuclear fusion energy through the technical and engineering verification. In ITER project, we plan to procure the blanket systems which has the risk of technology and cost when it is newly developed. We are developing the manufacturing process and joining technology for the ITER blanket to complete the procurement with qualified blanket system. To evaluate the soundness of manufacturing process, specimen and mock-up tests are being prepared. Finally, we can obtain the key technology of nuclear fusion reactor especially on the blanket design, joining and manufacturing technology through the present project and these technologies will help the construction of Korea fusion DEMO reactor and the development of commercial nuclear fusion reactor in Korea. In 1st year, through the fabrication of the Cu/SS and Be/Cu joint specimen, fabrication procedure such as ...
In addition to the ability to solve the static transport equation, we have also incorporated time dependence into our parallel 3-D S{sub {ital N}} code DANTSYS/MPI. Using a semi-implicit scheme, DANTSYS/MPI is capable of performing time-dependent calculations for both fissioning and pure source driven problems. We have applied this to various types of problems such as nuclear well logging and prompt fission experiments. This paper describes the form of the time- dependent equations implemented, their solution strategies in DANTSYS/MPI including iteration acceleration, and the strategies used for time-step control. Results are presented for a model nuclear well logging calculation.
Abstract Normal human aging is accompanied by progressive brain tissue loss and cognitive decline; however, several factors are thought to influence brain aging. We applied tensor-based morphometry to high-resolution brain MRI scans to determine whether educational level or physical activity was associated with brain tissue volumes in the elderly, particularly in regions susceptible to age-related atrophy. We mapped the 3D profile of brain volume differences in 226 healthy elderly subjects (130F/96M; 77.9 3.6 SD years) from the Cardiovascular Health Study-Cognition Study. Statistical maps revealed the 3D profile of brain regions whose volumes were associated with educational level and physical activity (based on leisure-time energy expenditure). After controlling for age, sex, and physical...
The intermediate silicon layers detector (ISL) was proposed as a part of the upgraded CDF detector at the RUN-II of the Tevatron mean value of pp collider at Fermilab, scheduled to start in year 2000. The ISL is a large-radius (20-30 cm) silicon tracker with a total active area of about 3.5 m. Located in the region between the silicon vertex detector and the central outer tracker, the ISL will allow tracking in the forward region and significantly improve it in the central area. Together with the SVX II the ISL forms a standalone, 3D silicon tracker. The challenge is to build a low-cost device which provides precise 3D tracking in a approximately equal to 2 m long area with a minimal amount of material for the supporting structure. The conceptual design and the status of the project are reviewed.
He ions incident at grazing angles on Cu(110) and Ni(110) surfaces are neutralised into triplet and singlet states, of which the 3p, 3d and 4d upper states are accessible to optical spectroscopy. In the energy range from 500 eV to 15 keV no significant energy dependence of the relative intensities of singlet and triplet lines was observed for scattering on Cu(110). The intensities from Ni(110) are higher and the singlet to triplet intensity ratio of the 3d to 2p transition is about 6% smaller than that from Cu(110). The results can be explained well by assuming resonant charge capture into excited He and intermediate formation of negative He/sup -/ states.
He ions incident at grazing angles on Cu(110) and Ni(110) surfaces are neutralised into triplet and singlet states, of which the 3p, 3d and 4d upper states are accessible to optical spectroscopy. In the energy range from 500 eV to 15 keV no significant energy dependence of the relative intensities of singlet and triplet lines was observed for scattering on Cu(110). The intensities from Ni(110) are higher and the singlet to triplet intensity ratio of the 3d to 2p transition is about 6% smaller than that from Cu(110). The results can be explained well by assuming resonant charge capture into excited He and intermediate formation of negative He"- states. (orig.).
DVR project concerns the creation of a virtual reality OpenGL system for desktop applications in archaeology. The main goal is the creation of a 3D information system using the real time interaction of OpenGL environments. The first case study implemented is the Vettii House, one of the most important and outstanding monuments in Pompei. The virtual reconstruction of these architectural models is based on very detailed photogrammetric surveys and it is connected with information layers and archaeometric data-bases regarding the state of conservation of walls, structures and any type of materials of the monument. A full 3D interface characterizes the system, comprising a high resolution texturing with detailed volumetric and geometric data. Finally, for the future, the project plans to fit the system for scientific and end users through the installation of stations on site.
In this paper we review and classify the various patterns of isosteric heat versus loading for adsorption of gases on graphitised thermal carbon black at temperatures ranging from below the 3D triple point to temperatures above it, but less than the 3D critical point. We have identified the features of heat curve and highlighted the microscopic origin of these features. The patterns vary with temperature and with the relative strength of the fluid-fluid interaction and solid-fluid interaction. For simple adsorptives (by simple we meant there is no strong association between fluid particles), the heat curve is typified by fluid-fluid attraction and layering phenomena. For adsorptives showing strong association such as water, ammonia and methanol, the heat curve essentially begins below the ...
The purpose of this project is to demonstrate targeted infill and extension drilling opportunities, better determinations of oil-in- place, methods for improved completion efficiency and the suitability of waterflooding in certain shallow-shelf carbonate reservoirs in the Williston Basin, Montana, North Dakota and South Dakota. Improved reservoir characterization utilizing 3-dimensional (3D) and multi-component seismic are being investigated for identification of structural and stratigraphic reservoir compartments. Field demonstrations are in progress to collect data for evaluation of horizontal completions in both the Red River and Ratcliffe. A vertical well in the Red River will test attribute analysis of 3D seismic data for prediction of porosity development. Additional seismic acquisitions and interpretation are in progress for both the Ratcliffe and Red River. A water-injectivity test in a new ...
Statement of problem Inadequate dimensioning of the connectors in a cantilever cross-arch fixed dental prosthesis (FDP) in perioprosthetic patients jeopardizes the prognosis of the restoration. Purpose The purpose of this study was to investigate the effect of increasing the vertical dimension (VD) on the maximum stress developed within the connectors during the static loading of a cross-arch FDP extended as a 1- and 2-unit cantilever. Material and methods Six digital models were developed, derived from a 3-dimensional (3-D) initial model. In the initial model, the teeth were prepared for metal ceramic restorations and splinted with a cross-arch FDP, extended as a 1- or 2-unit cantilever. The VDs of the connectors proximal to the retaining abutment were 3, 4, or 5 mm. A 3-D finite element ...
There is an ever increasing demand to perform flow simulations that incorporate the complete details of geometry as well as sophisticated flow physics. This has led to the development of numerical algorithms that can simulate the actual flow phenomena with greater fidelity. However, the success of these algorithms hinges on the grid that models the geometry. Grid generation methods for 2-D models have long existed and the general lack of complexity of the simpler 2-D models has not quite challenged the efforts in this area. However, demands for generating better 3-D geometric models for flow simulations involving complex geometries have completely changed the perspective of grid generation strategies. As a consequence, grid generation efforts have earned equal significance as that of numerical solver efforts.
The objective of this project is to develop multi-dimensional computational models in order to improve the operation of uranium electrorefiners currently used in pyroprocessing technology. These 2-D (US) and 3-D (ROK) mathematical models are based on the fundamental physical and chemical properties of the electrorefiner processes. The validated models by compiled and evaluated experimental data could provide better information for developing advanced electrorefiners for uranium recovery. The research results in this period are as follows: - Successfully assessed a common computational platform for the modeling work and identify spatial characterization requirements. - Successfully developed a 3-D electro-fluid dynamic electrorefiner model. - Successfully validated and benchmarked the two multi-dimensional models with compiled experimental data sets
Whereas in part 1 and 2 the detailed observation equations of terrestrial type for an integrated geodetic model are presented this paper will outline how the theory is transferred in an operational program. The main lines of functions of the FORTRAN IV program are discussed. Since the input specifications as well as the data requirements are described in detail and illustrated by example of input and output part 3 can serve as an user-guide for OPERA. OPERA is an acronym for operational adjustment. Besides the integrated determination of 3D-geocentric coordinates and the gravity disturbing potential the program can handle all cases of traditional geodesy (in total 13 variants of solution are provided) equivalent also with adjustments in ellipsoidal coordinates B, L or H, as well as constrained adjustments, pure prediction of the gravity disturbing field, etc.
Conformationally constrained analogue synthesis was undertaken to aid in pharmacophore mapping and 3D-QSAR analysis of nitrobenzylmercaptopurine riboside (NBMPR) congeners as equilibriative nucleoside transporter 1 (ENT1) inhibitors. In our previous study [J. Med. Chem. 2003, 46, 831-837], novel regioisomeric nitro-1,2,3,4-tetrahydroisoquinoline conformationally constrained analogues of NBMPR were synthesized and evaluated as ENT1 ligands. 7-NO2-1,2,3,4-Tetrahydroisoquino-2-yl purine riboside was identified as the analogue with the nitro group in the best orientation at the NBMPR binding site of ENT1. In the present study, further conformational constraining was introduced by synthesizing 5prime-O,8-cyclo derivatives. The flow cytometrically determined binding affinities indicated that the...
At Super-LHC luminosity it is expected that the standard suite of L1 triggers for CMS will saturate. Information from the tracker will be needed to reduce trigger rates to satisfy the L1 bandwidth. Tracking trigger modules which correlate information from closely-spaced sensor layers to form an on-detector momentum filter are being developed by several groups. We report on a trigger module design which utilizes three dimensional IC technology to incorporate chips which are connected both to the top and bottom sensor, providing the ability to filter information locally. A demonstration chip, the VICTR, has been submitted to the Chartered/Tezzaron two-tier 3D run coordinated by Fermilab. We report on the 3D design concept, the status of the VICTR chip and associated sensor integration utilizing oxide bonding.
One of the stiffest challenges in structural studies of proteins using NMR is the assignment of sidechain resonances. Typically, a panel of lengthy 3D experiments are acquired in order to establish connectivities and resolve ambiguities due to overlap. We demonstrate that these experiments can be replaced by a single 4D experiment that is time-efficient, yields excellent resolution, and captures unique carbon-proton connectivity information. The approach is made practical by the use of non-uniform sampling in the three indirect time dimensions and maximum entropy reconstruction of the corresponding 3D frequency spectrum. This 4D method will facilitate automated resonance assignment procedures and it should be particularly beneficial for increasing throughput in NMR-based structural genomics initiatives.
We propose new method of assessment of histological images for medical diagnostics. 2-D image is preprocessed to form 1-D landscapes or 1-D signature of the image contour and then their complexity is...Full Text Available
In vivo two-photon imaging through the pupil of the primate eye has the potential to become a useful tool for functional imaging of the retina. Two-photon excited fluorescence images...Full Text Available
This paper describes Image Engine, an object-oriented, microcomputer-based, multimedia database designed to facilitate the storage and retrieval of digitized biomedical still images, video, and text...Full Text Available
Adaptive image processing is one of the most important techniques in visual information processing, especially in early vision such as image restoration, filtering, enhancement, and segmentation. This work focuses on applications of advanced CI techniques in image processing applications
Modeling artificial scanning electron microscope (SEM) and scanning ion microscope images has recently become important. This is because of the need to provide repeatable images with a priori determined parameters. Modeled artificial images are highly useful in the evaluation of new imaging and metrological techniques, like image-sharpness calculation, or drift-corrected image composition (DCIC). Originally, the NIST-developed artificial image generator was designed only to produce the SEM images of gold-on-carbon resolution sample for image-sharpness evaluation. Since then, the new improved version of the software was written in C++ programming language and is in the Public Domain. The current version of the software can generate arbitrary samples, any drift function, and many other features. This ...
Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula
Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula.
OBJECTIVETo assess the new quantitative bone scan parameters as markers of Charcot neuroosteoarthropathy (CNO) activity.RESEARCH DESIGN AND METHODSForty-two...Full Text Available
Emphasis was put on the comparative quantitative structure-activity approaches to the exploration of action mechanisms of structurally different classes of compounds showing the same type of activity...Full Text Available
Effective small interfering RNA (siRNA)–mediated therapeutics require the siRNA to be delivered into the cellular RNA-induced silencing complex (RISC). Quantitative information of this essential...Full Text Available
A single radial hemolysis test was developed for quantitation of specific antibody to non-hemagglutinating viruses. With the human coronaviruses as models, this test utilizes the binding properties...Full Text Available
We have exploited ``progeny testing'' to map quantitative trait loci (QTL) underlying the genetic variation of milk production in a selected dairy cattle population. A total of 1,518 sires, with progeny...Full Text Available
Gene expression data has been used in lieu of phenotype in both classical and quantitative genetic settings. These two disciplines have separate approaches to measuring and interpreting epistasis, which...Full Text Available
Deficits in prepulse inhibition (PPI) are a biological marker for schizophrenia. To unravel the mechanisms that control PPI, we performed quantitative trait loci (QTL) analysis on 1,010 F2 mice derived...Full Text Available
The Electronic REference To access In vivo Concentrations (ERETIC) method was applied to 1H HR-MAS spectroscopy. The accuracy, precision, and stability of ERETIC as a quantitative...Full Text Available
A diverse set of digital image-processing applications exists at the Lawrence Livermore National Laboratory. While many of these include some sort of image analysis or restoration, virtually all of them require image-enhancement procedures. In this paper we describe the principal image-processing facility at the Laboratory, followed by a discussion of several of the major image-processing application areas.
On-orbit spectral calibration of hyperspectral imaging data is a key step for quantitatively analyzing them. Like the atmospheric correction, accurate spectral calibration is very necessary for improved studies of land or ocean surface properties. Based on the previous literatures, a new method which coupled an optimization algorithm was developed to simultaneously retrieve the central wavelength and the full width at half maximum (FWHM) of the hyperspectral sensor without needing the in situ reflectance spectra. Firstly, the Hyperion data set simulated using MODTRAN4 with the Hyperion spectral specification was used to test the new method, and the results indicated that the maximum error was less than 0.1 and 0.7 nm for central wavelength and FWHM respectively when the spectral shift is 5 nm. Then the algorithm was applied to the Hyperion data acquired on May 20, 2008 over Heihe River Basin and it was iteratively performed for each detector of ...
Part I of this thesis is on long-term iceberg collision-risk assessment methods for fixed offshore structures. Estimates for the long-term probability that an iceberg will hit a fixed offshore structure are based on estimates of the total volume of produced iceberg, a model for the size distribution of icebergs and a description of how iceberg trajectories ``fill`` the plane (the ocean`s surface). Part II of the thesis discusses methods for analysis of low resolution data in the sense that the size of the area covered by each pixel is not small compared to the dominating floes. Still, this type of data can provide estimates of the ice extent (and hence the ice edge) and ice concentration. The estimates of the ice edge (at least) seem to be physically significant in the sense that ``in some way`` they can reflect ice drift in an image time sequence. A priori this is far from obvious. A central idea is that the ``ice edge`` is close to a transition zone between two ...
Radioimmunotherapy (RIT) is a new treatment option for patients with non-Hodgkin lymphoma (NHL). Response to RIT currently remains difficult to predict using conventional prognostic factors and could be refined using functional imaging. The goal of this work is to evaluate the value of 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in predicting response to Yttrium 90-labeled monoclonal antibodies for patients with NHL. Thirty-five patients with NHL who had undergone 18F-FDG PET prior to RIT with either 90Y-ibritumomab tiuxetan (group A; n=17) or 90Y-epratuzumab tetraxetan (group B; n=18) were included in this retrospective study. Four functional criteria were determined for each tumour lesion in a given patient: maximum and mean standard uptake values (SUVmax and SUVmean), functional lesion volume (LVol) and total lesion glycolysis (TLG, product of the volume and the SUVmean). For each patient, we determined highest SUVmax and SUVmean, cumulative ...
Polycyclic aromatic hydrocarbons (PAHs) are combustion products of organic materials, mixtures of which contain multiple known and probable human carcinogens. PAHs occur in indoor and outdoor air, as well as in char-broiled meats and fish. Human exposure to PAHs occurs by inhalation, ingestion and topical absorption, and subsequently formed metabolites are either rendered hydrophilic and excreted, or bioactivated and bound to cellular macromolecules. The formation of PAH-DNA adducts (DNA binding products), considered a necessary step in PAH-initiated carcinogenesis, has been widely studied in experimental models and has been documented in human tissues. This review describes immunohistochemistry (IHC) studies, which reveal localization of PAH-DNA adducts in human tissues, and semi-quantify PAH-DNA adduct levels using the Automated Cellular Imaging System (ACIS). These studies have shown that PAH-DNA adducts concentrate in: basal and supra-basal epithelium of the ...
The detection and quantification of defined reaction products of chemical mutagens and carcinogens (and of many cancer chemotherapeutic agents) with DNA require highly sensitive analytical techniques. The exceptional capability of immunoglobulins to recognize subtle alterations of molecular structure (especially when monoclonal antibodies are used to maximize specificity), outstanding sensitivity of immunoanalysis by high-affinity antibodies, and the fact that radioactively-labelled agents are not required suggest the utility of a radioimmunoassay to recognize and quantitate alkylated DNA products. We have recently developed a set of high-affinity monoclonal antibodies (secreted by mouse x mouse as well as by rat x rat hybridomas; antibody affinity constants, 10"9 to > 10"1"0 lmol) specifically directed against several DNA alkylation products with possible relevance in relation to both mutagenesis and malignant transformation of mammalian cells. These alkylation ...
Based on their interesting properties, metal nanoparticles show the potential as an analytical tool in electronic (Burmeister et al. 2004), optical (Yguerabide and Yguerabide 1998), and catalytic applications (Liu 2006). Their characteristics depend on the composition, shape, and size of the single particles. These various properties are utilized in many different approaches such as optics, magnetics (Lang et al. 2007), and laser technology (Csaki et al. 2007). We investigated an alternative method for the synthesis of nanoparticles. In this case, an enzyme, horseradish peroxidase, induces a silver deposition and replaces a metal nanoparticle as the reaction seed. Depending on the reaction time, we could obtain particles in a range of few nanometers up to more than 250 nm. For a better understanding of the enzymatic silver deposition process, the silver particles produced by this process were analyzed by SEM, TEM, and atomic force microscopy (AFM) on a single particle level after ...
The object and the purpose of the present work was to develop, to assemble and to start running a new TOF (time of flight) mass spectrometer for imaging SNMS analytic which is optimized for the analysis of highly molecular secondary ions. The most important purpose was the characterization of the TOF mass spectrometer. The obtained mass spectra of indium, tantalum and silver clusters reflect the excellent properties of the TOF mass spectrometer for the detection of large clusters with good detection efficiency up to masses of 16000 amu. The possibility of the deflection of selected saturated atom and cluster peaks serves for further improvement of the detection efficiency for large molecules. The accessible mass resolution was determined to be of the order of m/{delta}m=1000 in the high mass region. Numerous measurements were carried out to characterize the useful yield of this spectrometer. For a best possible adaptation of the TOF mass spectrometer for the ...
Involvement of the dopaminergic system has been suggested in patients suffering from attention deficit hyperactivity disorder (ADHD) since the symptoms can be successfully treated with methylphenidate, a potent blocker of the dopamine transporter (DAT). This study reports the findings on the status of the DAT in adults with ADHD before and after commencement of treatment with methylphenidate, as measured using [{sup 99m}Tc]TRODAT-1. Seventeen patients (seven males, ten females, aged 21-64 years, mean 38 years) were examined before and after the initiation of methylphenidate treatment (3 x 5 mg/day). All subjects were injected with 800 MBq [{sup 99m}Tc]TRODAT-1 and imaged 3 h p.i. Single-photon emission tomography (SPET) scans were acquired using a triple-headed gamma camera. For semi-quantitative evaluation of the DAT, transverse slices corrected for attenuation were used to calculate specific binding in the striatum, with the cerebellum used ...
A review of current daylighting design tools indicates that over 30 tools are now available, including nomographs, protractors, overlays, and programs for micro-, mini-, and mainframe computers. Computer-based tools allow testing and analyzing of more design alternatives under a wider variety of conditions than was previously practical with slower techniques, but they have not fundamentally changed the information available to the design professional. These tools are applicable to certain limited functions of the design process and do not address the varying information needs of the designer at various points in the design process. We describe a concept for a computer-based building envelope design tool that is structured to overcome many of the limitations of the existing tools. The tool would address daylighting design in the context of the overall building envelope design, covering a range of environmental quality issues in addition to quantitative aspects of ...
Gamma scanning measurements are used to determine the radioactive nuclides from an irradiated fuel rod in a hot cell which is a routine task in the Irradiated Materials Examination Facility (IMEF) of the Korea Atomic Energy Research Institute (KAERI), Total gamma spectra of radioactive nuclides and the atomic ratio of {sup 134}Cs to {sup 137}Cs in a few segments of a single fuel rod are measured by the present gamma scanning system. For the purpose of determining the radioactive nuclide's distribution in detail within a fuel rod quantitatively, we attempt to upgrade the present gamma scanning system in this paper, therefore, an investigation of the feasibility of the tomographic gamma scanning (TGS) technique, which is one of the promising nondestructive assay (NDA) methods is proposed. The TGS technique is an efficient method and it has an accurate precision for the characterization of several fuel parameters. In this paper, a principle and an emission ...
The synthesis and structures of acyclic and macrocyclic thio-, seleno- and telluro-ether complexes of the metallic and metalloid elements of Groups 13-16 reported since 2000 are described. The diverse structures range from discrete monomers through to infinite 1-, 2- or 3-D polymers. The coordination chemistry in this area is quite different to familiar d-block chemistry and the underlying factors are explored. PMID:21706103
The main features are presented of a computer programme for 3-D thermohydraulic and thermodynamic analysis of the PGV-1000 horizontal steam generator used at the Temelin NPP. The programme provides analyses of primary side hydraulics, heat exchange behavior and the steam generator secondary side thermohydraulics and thermodynamics. Given are calculated data on the circulation flow rate, void fraction, heat transfer dynamics and the swelled level. (Z.S.) 9 figs.
This paper describes the calculation method of 3-D underground structures in TDME method which measures only field components. Recently, FDTD method was developed as calculation method in time domain difference calculus, and the forward analysis accuracy of 3-D fields was rapidly improved. The survey results using a large-scale loop (600m{times}360m) were numerically analyzed by FDTD method. 16 measuring lines were prepared in both X and Y directions, and measuring points were prepared on intersection points of the measuring lines. Since signal current is staircase one, step and impulse responses of the ground were determined by calculating magnetic field and its time differentiation. The rectangular body (120m{times}120m{times}100m) of 0.2S/m in conductivity (5 ohm m in resistivity) was installed 160m under the ground as 3-D resistivity anomaly. The ground of ...
We report on solid solution CePd_2_-_xMn_xSi_2 which shows an interesting transition of the Ce-ion from magnetism in a Kondo regime to an intermediate valence state coupled with a strongly magnetic 3d sublattice. ((orig.)).
We report on solid solution CePd[sub 2-x]Mn[sub x]Si[sub 2] which shows an interesting transition of the Ce-ion from magnetism in a Kondo regime to an intermediate valence state coupled with a strongly magnetic 3d sublattice. ((orig.))
Three-dimensional computer simulation and analyses of the horizontal steam generator thermal-hydraulics of the WWER 1000 nuclear power plant have been performed for 50% and 75% partial loads, 100% nominal load and 110% over-load. Presented results show water and steam mass flow rate vectors, steam void fraction spatial distribution, recirculation zones, swell level position, water mass inventory on the shell side, and other important thermal-hydraulic parameters. The simulations have been performed with the computer code 3D ANA, based on the 'two-fluid' model approach. Steam-water interface transport processes, as well as tube bundle flow resistance, energy transfer, and steam generation within tube bundles are modelled with {sup c}losure laws{sup .} Applied approach implies non-equilibrium thermal and flow conditions. The model is solved by the control volume procedure, which has been extended in order to take into account ...
Three-dimensional computer simulation and analyses of the horizontal steam generator thermal-hydraulics of the WWER 1000 nuclear power plant have been performed for 50% and 75% partial loads, 100% nominal load and 110% over-load. Presented results show water and steam mass flow rate vectors, steam void fraction spatial distribution, recirculation zones, swell level position, water mass inventory on the shell side, and other important thermal-hydraulic parameters. The simulations have been performed with the computer code 3D ANA, based on the 'two-fluid' model approach. Steam-water interface transport processes, as well as tube bundle flow resistance, energy transfer, and steam generation within tube bundles are modelled with "closure laws". Applied approach implies non-equilibrium thermal and flow conditions. The model is solved by the control volume procedure, which has been extended in order to take into account the ...
The electronic structure of octahedral metal atom clusters Me_6 of 3d, 4d, and 5d transition metal atoms (V, Cr; Nb, Mo; Ta, W) has been calculated applying two different quantum-chemical approximation methods (Extended Hueckel (EH) method; SW-Xsub(alpha) method). Equilibrium structures, energy level schemes, Fermi energies and band widths as well as densities of states of clusters are discussed in detail.
The influence that electromagnetic fields have on mechanical and electronic equipment was discussed. A three dimensional numerical simulation model of electric fields around high voltage power transmission lines was described. 4 refs., 1 tab., 5 figs.
The influence that electromagnetic fields have on mechanical and electronic equipment was discussed. A three dimensional numerical simulation model of electric fields around high voltage power transmission lines was described. 4 refs., 1 tab., 5 figs.
Under support from the French Space Agency (CNES), a 3D+t dusty-gas model of Comet 67P/Churyumov-Gerasimenko is being developed, to compute, from the first 2014 Rosetta orbital data, the aerodynamic forces exerted on the Rosetta orbiter and on the descent lander. We report the recently developed dust dynamics part of the code. The multi-species (presently H2O and CO) gas code is optimized in terms of computational speed owing to the use of two complementary methods: (a) 3D+t Direct Simulation Monte Carlo (DSMC) runs in the non-equilibrium regions adjacent to the surface and very distant from it, and (b) solutions of the Navier-Stokes equations in-between. The model is used presently using Lamy et al. (Space Sci. Rev., 2007, 128, 23) coarse information on 67P nucleus shape and rotation, and a range of possible gas production rates Q for the early Rosetta observations at rh 3 AU (Q 1026 - 1027 s-1). In ...
In this paper, finite-difference time-domain method is used to research the transient electromagnetic pulse (EMP) coupling to the cylinder object which is shielded in another shielding cavity with a hole numerically. The different coupling effectiveness of three transient EMP is simulated. The distribution of the electric field in the shielding cavity and the current on the cavity are researched. The shielding effectiveness is evaluated. (authors)
A method for calculation of absorbed dose distributions in three dimensions for 1-20 MeV photons is presented. The method uses convolution/superposition of photon fluence distributions with energy scattering kernels. Results for Co-60 and X-ray beams in homogeneous and inhomogeneous media are compared with measurements. Good agreement is found between calculations and measurements. 8 refs.; 3 figs.
The present research scholars are having keen interest in doing their research activities in the area of Data mining all over the world. Especially, [13]Mining Image data is the one of the essential features in this present scenario since image data plays vital role in every aspect of the system such as business for marketing, hospital for surgery, engineering for construction, Web for publication and so on. The other area in the Image mining system is the Content-Based Image Retrieval (CBIR) which performs retrieval based on the similarity defined in terms of extracted features with more objectiveness. The drawback in CBIR is the features of the query image alone are considered. Hence, a new technique called Image retrieval based on optimum clusters is proposed for improving user interaction with image retrieval systems by fully exploiting ...
For many years, {beta} radioactivity has been used to label molecules and follow them in various biological processes. {beta} imaging is obtained by autoradiography. Classically made on films or on photographic emulsions, autoradiography is now supplanted by radio-imagers which are very performing. The phosphor-imager, {beta}-imager and {mu}-imager are the systems mainly used today and their operating principles and properties are compared. The great advantages of these imagers are: their rapidity to obtain results and their reliability for absolute quantification. All emitters ({beta}{sup -}, {beta}{sup -} -{gamma} and {beta}{sup +}) are detectable as well as the gamma emitters of nuclear medicine, by means of their low energy electrons ejected during y emission. Phosphor-imager is well suited to energetic tracers and large series of ...
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...
Two geriatic male rhesus monkeys were used for the radioisotope imaging in this research. Discussion of the radionuclide, materials, and method used to accomplish the neurologic examination and the results obtained, both during the procedure and confirmation of the results by necropsies were accompanied by color photos of scan images. Results were that the nuclear images provided accurate images of intracranial neoplasia.
Computed radiography (CR) systems use a photostimulable phosphor plate enclosed in a cassette. In CR, image acquisition is a two-stage process wherein image capture and image read out are done separately. Direct digital radiography (DR) systems, on the other hand, use detectors that have a combined image capture and image read out capability. DR systems are also called as DDR or ddR systems by some vendors. This article focuses on DR systems
This paper examines the seismic signatures of discrete, finite-length fractures, and outlines an approach for elastic, prestack reverse-time imaging of discrete fractures. The results of this study highlight the importance of incorporating fracture-generated P-S converted waves into the imaging method, and presents an alternate imaging condition that can be used in elastic reverse-time imaging when a direct wave is recorded (e.g., for crosswell and VSP acquisition geometries).
Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only a small fraction of ...
The aim of this study was to assess the possibility of digital image analysis of pit-and-fissure discoloration in order to diagnose caries. Digital images showing pit-and-fissure discoloration in 100...Full Text Available
The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available
This paper discusses the clinical application and main objective of testicular imaging. The authors present cases that represent a spectrum of the abnormalities which might be detected by testicular imaging, with special attention given to testicular torsion and the acute diseases which may mimic it clinically. Accuracy of the test is noted.
Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. One key component of 4D radiotherapy planning...Full Text Available
PurposeAuto-propagation of anatomical region-of-interests (ROIs) from the planning CT to daily CT is an essential step in image-guided adaptive radiotherapy. The...Full Text Available
This paper proposes a novel method for computing linear basis images from tensor-valued image data. As a generalization of the nonnegative matrix factorization, the proposed method aims to approximate...Full Text Available
A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.
Multimodality imaging with PET/CT and SPECT/CT has become commonplace in clinical practice and in preclinical and basic medical research. Do other combinations of imaging modalities have a similar...Full Text Available
Purpose: Small animal micro-CT imaging is being used increasingly in preclinical biomedical research to provide phenotypic descriptions of genomic models. Most of this imaging is coincident...Full Text Available
Epifluorescence images of Ca2+ transients elicited by electrical stimulation of single skeletal muscle fibers were studied with fast imaging techniques that take advantage of the large fluorescence...Full Text Available
Optical coherence microscopy (OCM) is a promising technique or high resolution cellular imaging in human tissues. An OCM system for high-speed en face cellular resolution imaging...Full Text Available
This multiauthored text is aimed particularly toward the resident or registrar training in diagnostic radiology. This is a text book on the entire scope of diagnostic imaging. It includes techniques and imaging modalities of all the systems, head, face and neck. The book covers the entire gamut of diagnostic radiology.
The use of digital wound images would allow remote consultation between patients, physicians, or other caregivers over the Internet. To evaluate the efficacy and validity of digital images for assessment...Full Text Available
Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final...Full Text Available
Image registrations that are based on similarity measures simply adjust the parameters of an appropriate spatial transformation model until the similarity measure reaches an optimum. The numerous similarity measures that have been proposed in the past are differently sensitive to imaging modality, image content and differences in the image content, selection of the floating and target image, partial image overlap, etc. In this paper, we evaluate and compare 12 similarity measures for the rigid registration. To study the impact of different imaging modalities on the behavior of similarity measures, we have used 16 CT/MR and 6 PET/MR image pairs with known 'gold standard' registrations. The results for the PET/MR registration and for the registration of CT to both rectified and unrectified MR ...
An image slicing spectrometer (ISS) for microscopy applications is presented. Its principle is based on the redirecting of image zones by specially organized thin mirrors within a custom fabricated...Full Text Available
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...
ObjectiveThis study was conducted to evaluate a computer-imaging program called HAAIR (Help with Adjustment to Alopecia by Image Recovery) that was developed to provide...Full Text Available
Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available
Post-mortem magnetic resonance (MR) imaging is of increasing interest not only as an alternative to autopsy but as a research tool to aid the interpretation and diagnosis of in utero MR images. The information from the post-mortem MR has allowed the development of imaging sequences applicable to in utero imaging and neonatal imaging. It has established brain development during gestation and has provided data on this to which in utero MR can be compared. The detail available from the post-mortem images is such that brain development can be studied in a non-invasive manner, a permanent record on the normal and abnormal areas is available and a greater understanding of developmental abnormalities is possible.
The central nervous system is involved in 10-20% of cases in Lyme disease. The neurological symptoms, time course of the disease and imaging findings are multifaceted. We report two patients with cervical radiculitis. Magnetic resonance imaging revealed strong enhancement of the cervical nerve roots on contrast-enhanced T1-weighted images. These imaging patterns of borrelia-associated radiculitis have not been reported before. Knowledge of these imaging features may help to diagnose neuroborreliosis, which presents with non-specific symptoms. (orig.)
Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)
Aug 25, 2004 ... The Tropical Rainfall Measuring Mission or TRMM satellite provided this image of Typhoon Aere over the western Philippine Sea as it was ...
Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available
Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available
Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy electron beam therapy. (author)
A method of increasing information content for content-based image retrieval (CBIR) systems includes the steps of providing a CBIR database, the database having an index for a plurality of stored digital images using a plurality of feature vectors, the feature vectors corresponding to distinct descriptive characteristics of the images. A visual similarity parameter value is calculated based on a degree of visual similarity between features vectors of an incoming image being considered for entry into the database and feature vectors associated with a most similar of the stored images. Based on said visual similarity parameter value it is determined whether to store or how long to store the feature vectors associated with the incoming image in the database.
An image-analysis system, based on commercially available data visualization software (IDL [1]), allows convenient interaction with image data while still providing calculated beam parameters at a rate of up to 2 Hz. Image data are transferred from the IOC to the workstation via EPICS [2] channel access. A custom EPICS record was created in order to overcome the channel access limit of 16k bytes per array. The user can conveniently calibrate optical transition radiation (OTR) and fluorescent screens, capture background images, acquire and average a series of images, and specify several other filtering and viewing options. The images can be saved in either IDL format or APS-standard format (SDDS [3]), allowing for rapid postprocessing of image data by numerous other software tools.
This paper presents two imaging methods by using cross correlation. The one method images the subsurface by cross-correlation of the observed data and partial derivative seismograms calculated for a guessed model. The other method images the interface by use of cross-correlation of the virtual sources and the back propagated wave fields calculated from the observed data. Experimental tests show that both methods image subsurface interfaces well even if the guessed model is different from the true one. These imaging methods are reverse time migration that we perform cross-correlation as an imaging condition and have an advantage, as compared to conventional waveform inversion method, that images subsurface structure without iterative perturbation of the assumed model. (author). 18 refs., 15 figs.
Over the past decade, dramatic increases in computational power and improvement in image analysis algorithms have allowed the development of powerful computer-assisted analytical approaches...Full Text Available
AFFF has fabricated the (U, Pu)O_2 mixed oxide fuels for PHWRs, BWRs, PFBRs and FBTRs. The quantitative dissolution of the fuel samples are required within time for accurate determination of uranium-plutonium in chemical quality control laboratory. This paper describes the use of microwave heating technique in quantitative dissolution of (U, Pu)O_2 MOX (from 0.4% to 44% PuO_2). (author)
Hyogo-ken Nanbu earthquake with a focus in the Akashi straits has given huge earthquake damages in and around Awaji Island and Kobe City in 1995. It is clear that the basement structure, which is steeply deepened at Kobe City from Rokko Mountains towards the coast, and the focus under this related closely to the local generation of strong ground motion. Generation process of the strong ground motion was discussed using 2D and 3D numerical simulation methods. The 3D pseudospectral method was used for the calculation. Space of 51.2km{times}25.6km{times}25.6km was selected for the calculation. This space was discretized with the lattice interval of 200m. Consequently, it was found that the basement structure with a steeply deepened basement, soft and weak geological structure thickly deposited on the basement, and earthquake faults running under the boundary of base rock and sediments related greatly to ...
This paper is concerned with the validation of the 3D deterministic neutral-particle transport theory code EVENT for shielding applications. The code is based on the finite element-spherical harmonics (FE-P{sub N}) method which has been extensively developed over the last decade. A general multi-group, anisotropic scattering formalism enables the code to address realistic steady state and time dependent, multi-dimensional coupled neutron/gamma radiation transport problems involving high scattering and deep penetration alike. The powerful geometrical flexibility and competitive computational effort makes the code an attractive tool for shielding applications. In recognition of this, EVENT is currently in the process of being adopted by the UK nuclear industry. The theory behind EVENT is described and its numerical implementation is outlined. Numerical results obtained by the code are compared with predictions of the Monte Carlo code MCBEND and ...
The software package VIBA-lab1, which incorporates PIXE and RBS energy spectra simulation has now been extended to include the simulation of elemental maps from 3D structures. VIBA-lab1 allows the user to define a wide variety of experimental parameters, e.g. energy and species of incident ions, excitation and detection geometry, etc. When the relevant experimental parameters as well as target composition are defined, the program can then simulate the corresponding PIXE and RBS spectra. VIBA-LAB2 has been written with applications in nuclear microscopy in mind. A set of drag-and-drop tools has been incorporated to allow the user to define a three-dimensional sample object of mixed elemental composition. PIXE energy spectra simulations are then carried out on pixel-by-pixel basis and the corresponding intensity distributions or elemental maps can be computed. Several simulated intensity distributions for some ...
Spatially resolved studies of star forming regions show that the assumption of spherical geometry is not realistic in most cases, with a major complication posed by the gas being ionised by multiple non-centrally located stars or star clusters. We try to isolate the effects of multiple non-centrally located stars on the temperature and ionisation structure of HII regions, via the construction of 3D photoionisation models using the 3D Monte Carlo photoionisation code MOCASSIN. We find that the true temperature fluctuations due to the stellar distribution (as opposed to the large-scale temperature gradients due to other gas properties) are small in all cases and not a significant cause of error in metallicity studies. Strong emission lines from HII regions are often used to study the metallicity of star-forming regions. We compare integrated emission line spectra from our models and quantify any ...
Performance of SRF cavities are limited by non-linear localized effects. The variation of local material characters between "hot" and "cold" spots is thus of intense interest. Such locations were identified in a BCP-etched large-grain single-cell cavity and removed for examination by high resolution electron microscopy (SEM), electron-back scattering diffraction microscopy (EBSD), optical microscopy, and 3D profilometry. Pits with clearly discernable crystal facets were observed in both "hotspot" and "coldspot" specimens. The pits were found in-grain, at bi-crystal boundaries, and on tri-crystal junctions. They are interpreted as etch pits induced by surface crystal defects (e.g. dislocations). All "coldspots" examined had qualitatively low density of etching pits or very shallow tri-crystal boundary junction. EBSD revealed the crystal structure surrounding the pits via crystal phase orientation mapping, while ...
The Sunyaev-Zeldovich (SZ) effect gives a measure of the thermal energy and electron pressure in groups and clusters of galaxies. In the near future SZ surveys will map hundreds of systems, shedding light on the pressure distribution in the systems. The thermal energy is related to the total mass of a system of galaxies, but it is only a projection that is observed through the SZ effect. A model for the 3D distribution of pressure is needed to link the SZ signal to the total mass of the system. In this work we construct an empirical model for the 2D and 3D SZ profile, and compare it to a set of realistic high resolution SPH simulations of galaxy clusters and groups, and to a stacked SZ profile for massive clusters derived from WMAP data. Furthermore, we combine observed temperature profiles with dark matter potentials to yield an additional constraint, under the assumption of hydrostatic equilibrium. We ...
In the case where sources and receivers are not distributed on a 2-D plane, seismic tomography inversion was studied. In tomography experiments, the existing wells are generally used. In such case, sources and receivers are frequently not distributed on a 2-D plane. The 2.5-D analysis method including 2-D structure and 3-D ray-tracing was thus developed. This method is featured by less memory necessary for ray-tracing calculation, and the same algorithm for velocity determination as 2-D analysis method. In previous methods, since analysis is generally carried out by projecting sources and receivers on a certain assumed 2-D plane, it can derive correct results in the case of constant velocity and straight ray, however, in the other case, it derives incorrect results. Application of 3-D tomography requires a large amount of memory, and falls into poor convergence because of various parameters. The 2.5-D ...
The transition region between the straight part and the ends of the coils of the LHC model and prototype dipole magnets are often identified as the origin of training quenches. In order to study how the discontinuities in the material properties of these regions affect coil pre-stress and possibly gain more insight in the quench behavior, a program was set up at CERN to analyze by 3D-FEM these particular regions. The ACCEL team, who performed a similar analysis for the main quadrupoles of the Superconducting Supercollider SSC, is entrusted with this program. In this paper we report on the results of 3D-modeling and analysis of the coil return end region, including the complete coil mass, of a 1-m single bore model magnet. This magnet represents all relevant features of the "two-in-one" LHC main dipole design concerning the winding configuration, the collar pack, the yoke, and the outer shell ...
Current advanced CMOS source/drain engineering involves the use of amorphizing implants with 3D geometry. Upon annealing, the induced transient enhanced diffusion (TED) can only be accurately predicted if the amorphized region is correctly modeled, as well as the formation and evolution of extended defects, particularly 3 1 1's and dislocation loops. In addition to the extended defects, already modeled in the atomistic kinetic Monte-Carlo simulator DADOS, we have developed a physically based modeling approach for the implant-induced damage build-up, amorphization and recrystallization, suitable to handle device-size process simulation. It is based on amorphous pockets (3D, irregular shape agglomerates of an arbitrary number of interstitials and vacancies, plus trapped impurities) with a size-dependent activation energy for recombination. The model is able to reproduce experimental aspects like ...
Current advanced CMOS source/drain engineering involves the use of amorphizing implants with 3D geometry. Upon annealing, the induced transient enhanced diffusion (TED) can only be accurately predicted if the amorphized region is correctly modeled, as well as the formation and evolution of extended defects, particularly 3 1 1's and dislocation loops. In addition to the extended defects, already modeled in the atomistic kinetic Monte-Carlo simulator DADOS, we have developed a physically based modeling approach for the implant-induced damage build-up, amorphization and recrystallization, suitable to handle device-size process simulation. It is based on amorphous pockets (3D, irregular shape agglomerates of an arbitrary number of interstitials and vacancies, plus trapped impurities) with a size-dependent activation energy for recombination. The model is able to reproduce experimental aspects like the ...
The paper deals with the modeling and the development of a numerical procedure for the analysis of shape-memory alloy (SMA) elements in order to predict the main features of SMA devices. A 3D SMA model in the framework of small strain theory is developed starting from the thermo-mechanical model proposed by Souza et al. (Eur J Mech A/Solids 17:789-806, 1998) and modified by Auricchio and Petrini (Int J Numer Methods Eng 55:1255-1284, 2002). The aim of this paper is to propose some more modifications to the original model, to derive its consistent 1D formulation, to clarify the mechanical meaning of the material parameters governing the constitutive model. A robust time integration algorithm is developed in the framework of the finite element method and a new beam finite element is proposed. Some numerical applications and a comparison with experimental data available in literature are carried out in order to assess the ability of the proposed ...
The improvement in the functions of the viscous flow calculation method VEGA-SHIP around a ship and the expansion of application range were described as the numerical flow simulation in ship and ocean engineering and at the same time application examples to the ocean engineering by the general-purpose flow simulation code FLOW-3D handling the non-steady flow with a free surface were introduced as the numerical simulation regarding such products as a water gate and a dam. In the VEGA-SHIP, water surface was handled as a fixed wall so that wave could not be calculated. Therefore, an algorithm for calculating wave on the water surface was added to the VEGA-SHIP and a calculation method simultaneously considering the creation of wave around the ship and viscosity was developed. The FLOW-3D was used to calculate the phenomenon where inside liquid moved greatly due to the oscillation of a tank and hit against ...
Results of our systematic NMR study in high T_c cuprates are reviewed. The antiferromagnetic spin fluctuations (AFSF) decrease in the order of La_1_._8_5Sr_0_._1_5CuO_4. YBa_2Cu_3O_7 and Tl_2Ba_2CuO_6_+_y. 1/T_1 of "6"3Cu in the CuO_2 plane in the normal state follows essentially a Curie-Weiss law at high temperature and T_1T = const. law at low temperature. The temperature dependence of 1/T_1 and the Knight shift together with their impurity effect in the superconducting state strongly suggest d-wave pairing implying the AFSF to be responsible for the occurrence of superconductivity. From the NQR frequency measurement the density of Cu 3d and O 2p holes decreases and increases, respectively, in the order of La, Y and Tl compounds, which is consistent with the change of AFSF. The relation between T_c and #nu#_Q, and their pressure dependence suggest that there exists and optimum value of the ratio of Cu ...
K{beta}-to-K{alpha} X-ray intensity ratios of Ti, V, Cr, and Co in pure metals and their disilicide compounds have been measured following excitation by 59.54 keV {gamma}-rays from a 200 mCi {sup 241}Am point-source. The K{beta}-to-K{alpha} intensity ratios of all these metals in the disilicide compounds are found to be less than the corresponding ratios for pure metals. Comparison of the measured K{beta}-to-K{alpha} intensity ratios for the disilicides and pure metals with the multiconfiguration Dirac-Fock calculations indicates increase of the 3d electron populations of Ti, V, Cr, and Co in the disilicides from their pure metal values suggesting the rearrangement of electrons between 3d and 4s states of the individual metal atom. This rearrangement is found to be opposite to that observed in our previously reported work on NiSi{sub 2} and CuSi{sub 2}.
K#beta#-to-K#alpha# X-ray intensity ratios of Ti, V, Cr, and Co in pure metals and their disilicide compounds have been measured following excitation by 59.54 keV #gamma#-rays from a 200 mCi "2"4"1Am point-source. The K#beta#-to-K#alpha# intensity ratios of all these metals in the disilicide compounds are found to be less than the corresponding ratios for pure metals. Comparison of the measured K#beta#-to-K#alpha# intensity ratios for the disilicides and pure metals with the multiconfiguration Dirac-Fock calculations indicates increase of the 3d electron populations of Ti, V, Cr, and Co in the disilicides from their pure metal values suggesting the rearrangement of electrons between 3d and 4s states of the individual metal atom. This rearrangement is found to be opposite to that observed in our previously reported work on NiSi_2 and CuSi_2.
Groom-Bailey decomposition analysis was carried out to investigate regional 3-D galvanic distortion on MT data in the central part of Northeastern Japan. Measuring sites were located nearly along the east-west line crossing Northeastern Japan. Three measuring lines (A, B, C) from the north to the south were prepared, and only data on the C line were analyzed in this paper. As a result, twist and shear were estimated to be not zero depending on local distortion in most of the sites. It was thus clarified that this method is not always perfect. This method was effective for regional 2-D structures, however, its application was doubtful to complicated 3-D underground structures in Japan. In order to obtain more accurate results, 2-D analysis using the impedance including no local distortion effect was necessary after the preliminary Groom-Bailey decomposition analysis. The direction of the wide area ...
This study examined the oxygen permeation behavior of Ce0.9Gd0.1O2-d (Gadolinium-Doped Ceria, GDC)/Ba0.5Sr0.5Co0.8Fe0.2O3-d (BSCF) composite membranes fabricated using a conventional sintering technique. GDC/BSCF composite membranes with a relative density >95% could be obtained when a green compact of BSCF and GDC was sintered at 1150^oC for 5h. It appears that GDC serves as a grain growth inhibitor because the average grain size of the composite decreased with increasing GDC content. The oxygen permeability of the BSCF and GDC/BSCF composite membranes strongly depends on the grain size and membrane thickness. The addition of GDC to BSCF resulted in a small grain size, low thermal expansion coefficient and high hardness. However, it is believed that oxygen permeation was blocked by GDC, a...
The 12 GeV upgrade at Jefferson Lab has identified two new large spectrometers as Physics detectors for the project. The first is a 7.5 Gev/c 35 m-sr. spectrometer that requires a pair of identical Combined Function Superconducting Magnets (CFSM) that can simultaneously produce 1.5 T dipole fields and 4.5 T/m quadrupole fields inside a warm bore of 120cm. The second is an 11 GeV/c 2 m-sr. spectrometer that requires a CFSM that simultaneously produces a dipole field of 4.0 T and a quadruple field of 3.0 T/m in a 60 cm warm bore. Magnetic designs using TOSCA 3D have been performed to realize the magnetic requirements, provide 3d fields for optics analysis and produce field and force information for the engineering feasibility of the magnets. A two-sector cos( theta )/cos(2 theta ) design with a low nominal current density, warm bore and warm iron design has been selected and analyzed. These low current ...
X-ray magnetic diffraction (XMD) technique was applied to an orbital ordering compound of ferromagnetic YTiO_3 for the first time. The orbital-magnetic form factor #mu# _L(k) and the spin-magnetic form factor #mu# _S(k) were independently measured by utilizing the LS separation ability of the XMD. The #mu# _L(k) was measured for ten reciprocal-lattice points. No significant values of the #mu# _L(k) were observed for most of the reciprocal-lattice points within the estimated statistical errors, which suggested quenching of the orbital moment. The #mu# _S(k) was measured for 22 reciprocal-lattice points. Fourier synthesis of the #mu# _S(k) gave the spin density distribution m _S(r) in the real space. The obtained m _S(r) map shows the characteristic feature of the electron distribution of 3d electron in the t_2_g state of a Ti atom coordinated by O"2"- ions, in which the electrons are distributed away from the negative O"2"- ions. It is concluded ...
The decay channels of the Ar 2s"-"1 and 2p"-"1 and Kr 3p"-"1 and 3d"-"1 electronic hole states have been investigated by means of photoelectron-photoion coincidence measurements following innershell ionization using synchrotron radiation. With the method of final ion-charge resolving electron spectroscopy it has become possible to disentangle different contributions to the electron spectrum and to determine the decay probabilities P(nl"-"1#->#n+) of the above-mentioned hole states (nl"-"1) to the final ionic charge states n+. A high correlation with threefold or even fourfold charged ions has been found in all cases. Possible decay routes, via cascade or direct double Auger processes, are discussed on the basis of energy-level schemes calculated with the Hartree-Fock method. Special emphasis is laid on the examination of the Kr 3p"-"1 decay process, where the two fine-structure components (j=1/2,3/2) exhibit noticeably different decay ...
Core-collapse supernovae are among Nature's most energetic events. They mark the end of massive star evolution and pollute the interstellar medium with the life-enabling ashes of thermonuclear burning. Despite their importance for the evolution of galaxies and life in the universe, the details of the core-collapse supernova explosion mechanism remain in the dark and pose a daunting computational challenge. We outline the multi-dimensional, multi-scale, and multi-physics nature of the core-collapse supernova problem and discuss computational strategies and requirements for its solution. Specifically, we highlight the axisymmetric (2D) radiation-MHD code VULCAN/2D and present results obtained from the first full-2D angle-dependent neutrino radiation-hydrodynamics simulations of the post-core-bounce supernova evolution. We then go on to discuss the new code Zelmani which is based on the open-source HPC Cactus framework and provides a scalable AMR approach for ...
The alloying effects on K to L shell vacancy transfer probabilities (?KL) in 3d transition metals have been carried out by X-ray fluorescence studies of various alloy compositions. K X-ray intensity ratios of Ti, Cr, Fe, Co, Ni, and Cu elements in the FexNi1?x, FexCr1?x, NixCr1?x, FexCryNi1?(x+y), TixNi1?x, TixCo1?x, and CoxCu1?x alloys have been measured following excitation by 22.69keV X-rays from a 10 mCi 109Cd radioactive point source and ?KL values for alloying elements have been determined from these ratios. The spectrum of characteristic K-X-ray photons from samples were detected with a high resolution Si(Li) detector coupled to a 4 K multichannel analyzer. The present investigation makes it possible to ...
A continuous-time 7th-order Butterworth Gm-C low pass filter (LPF) with on-chip automatic tuning circuit has been implemented for a direct conversion DBS tuner in 0.35 mum SiGe BiCMOS technology. The filter's -3dB cutoff frequency f{sub 0} can be tuned from 4 to 40 MHz. A novel on-chip automatic tuning scheme has been successfully realized to tune and lock the filter's cutoff frequency. Measurement results show that the filter has -0.5 dB passband gain, +-5% bandwidth accuracy, 30 nV/Hz{sup 1/2} input referred noise, -3dBVrms passband IIP3, and 27 dBVrms stopband IIP3. The I/Q LPFs with the tuning circuit draw 13 mA (with f{sub 0} = 20 MHz) from 5 V supply, and occupy 0.5 mm{sup 2}.
Aim: There has been a great demand for developments of the radioligands to visualize the N-methyl-D-aspartate (NMDA) receptors by PET/SPECT. We have recently synthesized two C-11 labeled antagonists for the glycine-binding site on NMDA receptors. The aim of this work is to examine for their in vitro and in vivo binding characteristics, and to evaluate their potentials as PET radioligands for the NMDA receptors. Materials and methods: Two C-11 labeled 4-hydroxy-2-quinolones (1 and 2) were synthesized by conventional methylation of the corresponding phenols with ["1"1C]methyl iodide. In vitro and ex vivo quantitative autoradiographs with imaging plate, as well as animal PET, were employed in order to evaluate their in vitro and in vivo binding to the NMDA receptors. Results: The compound 1 showed the specific binding to rat brain slices with higher localization in the hippocampus and cerebral cortex than in the cerebellum. Both glycine ...
The three mammalian transforming growth factor (TGF)-? isoforms (TGF-?1, TGF-?2, and TGF-?3) differ in their putative roles in radiation-induced fibrosis in intestine and other organs. Furthermore, tissue specificity of TGF-? action may result from temporal or spatial changes in production and/or activation. The present study examined shifts in the cell types expressing TGF-? mRNA relative to TGF-? immunoreactivity and histopathological injury during radiation enteropathy development. A 4-cm loop of rat small intestine was locally exposed to 0, 12, or 21-Gy single doses of x-irradiation. Sham-irradiated and irradiated intestine were procured 2 and 26 weeks after irradiation. Cells expressing the TGF-?1, TGF-?2, or TGF-?3 transcripts were identified by in situ hybridization with digoxigenin-labeled riboprobes. Intestinal wall TGF-? immunoreactivity was measured using computerized image analysis, and structural radiation injury was assessed by ...
... These assumptions are quantitatively investigated by calculating tie icldti\\e inportance of ... A modified lon-shore current model is used to study the ...
BackgroundDiscrepancies between the conclusions of different meta-analyses (quantitative syntheses of systematic reviews) are often ascribed to methodological differences. The objective...Full Text Available
A specific application of single photon emission tomography to the relative quantitation of the pituitary region is described together with the results obtained in 19 patients with pituitary adenoma...Full Text Available
Motivation: Automatic recognition of cell identities is critical for quantitative measurement, targeting and manipulation of cells of model animals at single-cell resolution. It has been...Full Text Available
Typing Workshop": [Introductions] [Intro, DNA Basics, and Historical Perspective] [DNA Extraction] [Validation and QA/QC] [DNA Quantitation] [PCR Amplification] [STR Loci and Kits]...
BACKGROUND: An approach to the study of the pharmacokinetics of drugs in the lung is to measure their concentrations in bronchial biopsy specimens. The main criticism of this technique is that bronchial...Full Text Available
This laboratory exercise demonstrates some basic principles in parasitology by using experimental studies of the relationship of Hymenolepis diminuta with its rodent host.
Abstract: The current financial crisis has now led most major central banks to rely on quantitative easing. The unique Japanese experience of quantitative easing is the only experience which enables us to judge this therapy's effectiveness and the timing of the exit strategy. In this paper, we provide a new empirical framework to examine the effectiveness of Japanese monetary policy during the ''lost'' decade and quantify the effect of quantitative easing on Japan's activity and prices. We combine advantages of Markov-switching VAR methodology with those of factor analysis to establish two major findings. First, we show that the decisive change in regime occurred in two steps: it crept out from late 1995 and established itself durably in February 1999. Second, we show for the first time th...
Absolute measurements of cerebral blood flow (CBF) are an important endpoint in studies of cerebral pathophysiology. Currently no accepted method exists for in vivo longitudinal...Full Text Available
... and high-quality photospheric-phase Type II SN spectra to constrain core- collapse SN explosions, massive star evolution, and distances in the Universe ...
OBJECTIVEEvaluate the qualitative and quantitative differences between moderated and unmoderated on-line social support groups focused on asthma.DESIGNA...Full Text Available
Computer-Aided Prediction of Chemical Ecotoxicity on the basis of Quantitative Structure-Activity Relationships with the Use of Physico-Chemical Descriptors, Including H-bond Parameters
AIM: To investigate the effects of gallbladder stones on motor functions of the gallbladder and the dynamics of bile flow in asymptomatic gallstone disease.METHODS: Quantitative hepatobiliary...Full Text Available
BackgroundSeveral fractal and non-fractal parameters have been considered for the quantitative assessment of the vascular architecture, using a variety of test specimens and of computational...Full Text Available
OBJECTIVE AND DESIGNThis study used qualitative and quantitative methods to examine the reasons primary care physicians and nurses offered for their inability to initiate guideline-concordant...Full Text Available
The concentration of apolipoproteins was measured by quantitative immunoelectrophoresis in rat serum, in the lipoprotein-free ultracentrifugal fraction (density greater than 1.21) of serum, and in renal...Full Text Available
In this model, without dark matter, the flat rotation curves of galaxies and the mass-to-light ratios of clusters of galaxies are described quantitatively. The hypothesis is that the agent of gravitational...Full Text Available
We studied a novel universal spectrochemical series of six-coordinated octahedral 3d transition metal complexes, which can be used for any combination of central metal atom and ligand molecules. A two dimensional spectrochemical series could be used to estimate the ligand field splitting energy of not only known compounds but also the unknown compounds. Therefore, it should be possible to control the physical properties, such as the electronic and magnetic properties and the optical phenomena of octahedral transition metal complexes by modifying the ligand field splitting. PMID:19378561
We compute the entropy of a closed bounded region of space for pure 3d Riemannian gravity formulated as a topological BF theory for the gauge group SU(2) and show its holographic behavior. More precisely, we consider a fixed graph embedded in space and study the flat connection spin network state without and with particle-like topological defects. We regularize and compute exactly the entanglement for a bipartite splitting of the graph and show it scales at leading order with the number of vertices on the boundary (or equivalently with the number of loops crossing the boundary). More generally these results apply to BF theory with any compact gauge group in any space-time dimension.
A transient eddy current measurement method is presented to determine the thickness and conductivity of a conductive plate. The conductive plate is induced by an air-cored coil, the magnetic flux density along the axial is measured and the various signals corresponding to plates with different thickness and conductivity are calculated using a 3D transient eddy current simulator. Characteristic features are obtained from the transient response. A similarity-based modeling method is utilized in this study to estimate the thickness and conductivity of the conductive plate. (author)
This report details an investigation into the efficacy of two approaches to solving the radiation diffusion equation within a radiation hydrodynamic simulation. Because leading-edge scientific computing platforms have evolved from large single-node vector processors to parallel aggregates containing tens to thousands of individual CPU's, the ability of an algorithm to maintain high compute efficiency when distributed over a large array of nodes is critically important. The viability of an algorithm thus hinges upon the tripartite question of numerical accuracy, total time to solution, and parallel efficiency.
The results of photoemission spectroscopy using molybdenum and tantalum samples have been obtained from the new beamline 2B1 at Pohang Light Source. Beamline 2B1 is based on a spherical grating monochromator (SGM) which is equipped with five gratings. The photon energy range from 184 to 1100 eV was covered in this work using two gratings (Gratings 4 and 5). The photon energy resolution has been deduced from Ta Fermi-level spectra and 3d spectra of Mo.
The results of a study conducted by Working Group 10 of the AGARD Fluid Dynamics Panel to investigate the limits of boundary layer methods, both the integral and field type formulations, for calculating three-dimensional turbulent separated flow are presented. Test cases used to assess the boundary layer calculations included the DFLVR prolate spheroid at angle of attack and the NASA-Ames Wing C. Comparisons between boundary layer calculations and experimental data are presented for these test cases along with observations, conclusions, and recommendations.
A modified variable structure interacting multiple model (M-VSIMM) estimator for complex hybrid maneuver target tracking is presented. The M-VSIMM could potentially be applied to fire control systems (FCS) used on warships. Target model groups were designed using 3D dimensional dynamic target models. Optimal model group selection logic was proposed, contrary to the activation and termination logic in the original VSIMM. The system will respond faster with optimal model group selection logic. After performing simulations, the tracking performances of the Kalman, ?-?(-?), VDIE, IMM and M-VSIMM filters were compared under various maneuvering conditions.
This paper presents a numerical simulation with the EUROPLEXUS fast dynamics software of a pipe whipping phenomenon occurring in the thermal hydraulic conditions of a loss of coolant accident in a PWR primary circuit. Different physical phenomena take place simultaneously during the rupture and the whipping of the pipe such as plasticity, contact, large displacements, two-phase flow regime and fluid structure interaction. Two kinds of numerical models - a simplified pipeline model and a mixed 1D/3D model - are considered and compared throughout modelling and computation. Numerical results are compared with experimental data belonging to the Aquitaine II test campaign.
The use of global three-dimensional (3-D) models with satellite observations of CO2 in inverse modeling studies is an area of growing importance for understanding Earth s carbon cycle. Here we use the GEOS-Chem model (version 8-02-01) CO2 mode with multiple modifications in order to assess their impact on CO2 forward simulations. Modifications include CO2 surface emissions from shipping (0.19 PgC yr 1), 3-D spatially-distributed emissions from aviation (0.16 PgC yr 1), and 3-D chemical production of CO2 (1.05 PgC yr 1). Although CO2 chemical production from the oxidation of CO, CH4 and other carbon gases is recognized as an important contribution to global CO2, it is typically accounted for by conversion from its precursors at the surface rather than in the free troposphere. We base our model 3-D spatial distribution of ...
Argon ion laser induced fluorescence measurements were carried out in a multipolar filament discharge with a broadband diode laser centered on 668 nm, which stimulated a transition from the metastable state in Ar(II) 3d4F7/2 to 4p4D05/2. The intensity of the induced fluorescence at 442 nm was maximized by the optimization of the discharge parameters and the laser power. From the recovery of the background fluorescence after the laser was turned off, the ion diffusion coefficient was deduced and compared with the result inferred from the experiments of ion acoustic wave (IAW) damping.
This reports is a literature survey on models and correlations for determining flow pattern that are used to simulate thermal-hydraulics in nuclear reactors. Determination of flow patterns are a basis for obtaining physical values of wall/interfacial friction, wall/interfacial heat transfer, and droplet entrainment/de-entrainment. Not only existing system codes, such as RELAP5-3D, TRAC-M, MARS, TRACE, CATHARE) but also up-to-date researches were reviewed to find models and correlations
We study the energetics of island formation in Stranski-Krastanow growth within a parameter-free approach. It is shown that an optimum island size exists for a given coverage and island density if changes in the wetting layer morphology after the 3D transition are properly taken into account. Our approach reproduces well the experimental island size dependence on coverage, and indicates that the critical layer thickness depends on growth conditions. The present study provides a new explanation for the (frequently found) rather narrow size distribution of self-assembled coherent islands.
A chemically assisted micro-beam etching system for 3D microanalysis was designed. Using chemically assisted ion beam etching (CAIBE) method with FIB shave-off scanning, about several hundred micrometers clean cross-section will be acquired in a few hours. We use focused ion beam (FIB) and electron beam (EB) as micro-beams, halogen or halide mainly as reactive gases. The apparatus was manufactured based on this concept. We found that the FIB, Q-MS and SED worked as expected. The instrumentation has been completed.
This work deals with the development of wind maps in the Venezuelan coastal zones (South America). The Navier-Stokes equations for real viscous incompressible flow are discretized via the finite element method and they are applied to a full 3D numerical model. Two regions were analyzed: the Margarita island and the Paraguana peninsula, both of them located in the Caribbean Sea at the North of Venezuela. These regions were modeled by using a three dimensional control volume, discretized through hexaedric eight-noded finite elements. Some wind maps obtained in this research are presented and discussed. (author)
We report on the design, fabrication and testing of two superconducting passive microwave components, a quadrature hybrid and a 20 dB directional coupler. These components are designed to be integrated with superconducting qubits or Josephson parametric amplifiers and used in quantum information processing applications. For the coupler, we measure return loss and isolation > 20 dB, and insertion loss 20 dB and insertion loss < 0.3dB in a 10% band around 6.5 GHz. These values are within the design specifications of our application; however, we find a 7% difference between the designed and measured center frequency for the hybrid.
In this paper we report on multi-physics, multi-billion macroparticle simulation of beam transport in a free electron laser (FEL) linac for future light source applications. The simulation includes a self-consistent calculation of 3D space-charge effects, short-range geometry wakefields, longitudinal coherent synchrotron radiation (CSR) wakefields, and detailed modeling of RF acceleration and focusing. We discuss the need for and the challenges associated with such large-scale simulation. Applications to the study of the microbunching instability in an FEL linac are also presented.
A simple method allowing easy calculation of the spatial damage energy distributions for ion-implanted materials is presented. The direct procedure takes account of the variation with depth of the lateral spreading of implanted ions, as well as the effects of energy transport by the recoiling target atoms. The subsequent computer program LUPIN-3D provides three-dimensional damage distributions and allows the construction of damage energy mappings. Various substrates of technological interest are investigated and several fields of application of the calculation are envisaged. The density of cascades can therefore be determined and heterogeneous amorphization models can be implemented. (orig.).
A new technique for radon measurement in the natural environment was investigated. It is based on the use of activated charcoal and a track-etch detector. The charcoal acts as a radon collector from the air and the track-etch detector as a recorder of the alpha particles emitted by radon and its decay products. Our preliminary results show that the response of the new dosimeter to radon, using Deodorant activated charcoal (TOK, Yugoslavia) and a CR-39 track-etch detector, is 1.4 tracks cm{sup -2}/Bqm{sup -3}d, which is about eight times higher than that obtained with a standard track-etch dosimeter. (author).
The 3-D neutronics code COREDAX has been developed based on AFEN (Analytic Function Expansion Nodal) method for x-y-z geometry and for hex-z geometry. In this study, the COREDAX code, as a regulatory review tool independent of the designer's, was applied to the SMART reactor core that was designed by KAERI (Korea Atomic Energy Research Institute). For nuclear cross section generation, the HELIOS lattice code was used in this study. The preliminary results for steady state in various conditions are presented in this paper
Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a ...