Positron-emission tomography (PET) and PET/CT (computed tomography) are becoming increasingly important for diagnosis and treatment of cancer. Clinically relevant changes can sometimes be seen on PET that are not seen on other imaging modalities. However, PET is not suitable for guiding biopsy as the images are not obtained in real-time. Therefore, our research group has begun developing a concept for PET/CT-guided interventional procedures. This paper presents the rationale for this concept, outlines our research plan, and includes an initial study to evaluate the relative sensitivity of CT and PET/CT in detecting suspicious lesions. (orig.)
Multimodality imaging with PET/CT and SPECT/CT has become commonplace in clinical practice and in preclinical and basic medical research. Do other combinations of imaging modalities have a similar...Full Text Available
Objectives Clinical PET/MR requires the use of patient positioning aids to immobilize and support patients for the duration of the combined examination. Ancillary immobilization devices contribute to overall attenuation of the PET signal, but are not detected with conventional MR sequences and, hence, are ignored in standard MR-based attenuation correction (MR-AC). We report on the quantitative effect of not accounting for the attenuation of patient positioning aids in combined PET/MR imaging. Methods We used phantom and patient data acquired with positioning aids on a PET/CT scanner (Biograph 16, HI-REZ) to mimic PET/MR imaging conditions. Reference CT-based attenuation maps were generated from measured (original) CT transmission images (origCT-AC). We also created MR-like attenuation map...
We investigated the efficacy of combined FDG-PET/CT imaging for the diagnosis of small-size uveal melanomas and the feasibility of combining separate, high-resolution (HR) FDG-PET with MRI for its improved localization and detection. Patients, methods: 3 patients with small-size uveal melanomas (0.2-1.5 ml) were imaged on a combined whole-body PET/CT, a HR brain-PET, and a 1.5 T MRI. Static, contrast-enhanced FDG-PET/CT imaging was performed of head and torso with CT contrast enhancement. HR PETimaging was performed in dynamic mode 0-180 min post-injection of FDG. MRI imaging was performed using a high-resolution small-loop-coil placed over the eye in question with T2-3D-TSE and T1-3D-SE with 18 ml Gd-contrast. Patients had their eyes shaded during the ...
Positron emission tomography (PET) is the gold standard for non-invasive assessment of myocardial viability and allows accurate detection of coronary artery disease by assessment of myocardial perfusion. Magnetic resonance imaging (MRI) provides high resolution anatomical images that allow accurate evaluation of ventricular structure and function together with detection of myocardial infarction. Potential hybrid PET/MR tomography may potentially facilitate the combination of information from these imaging modalities in cardiology. Furthermore, the combination of anatomical MRI images with the high sensitivity of PET for detecting molecular targets may extent the application of these modalities to the characterization of atherosclerotic plaques and to the evaluation of angiogenetic or stem cell therapies, for example. This article reviews ...
Positron emission tomography (PET) and magnetic resonance imaging (MRI) studies were performed on a case of neuro-Behcet's syndrome. In accordance with the clinical signs, FDG PET (using /sup 18/F-labeled 2-F-2'-desoxyglucose) revealed disseminated storage defects in the cerebrum and cerebellum. Focal regions of enhanced signal intensity were demonstrated in the parietal white matter of the cerebrum in T2-weighted images and in the brain stem by MRI. (orig.).
Integration of positron emission tomography (PET) and magnetic resonance (MR) has become a topic of increasing interest to the imaging community over the past two years. In this text, the authors attempt to distinguish facts from fiction concerning such integrated systems. Analysis of existing information of combined imaging on existing brain PET/MR systems and imaging experience with PET-computed tomography (CT) is reviewed. Various types of system integration of PET and MR are discussed with completely independent systems on one hand and completely integrated systems with the possibility of simultaneous data acquisition on the other hand. Furthermore, it is discussed, what simultaneous data acquisition with nuclear imaging systems combined with MR or CT really means, as technical simultaneity may not be relevant in ...
A conventional PET scanner has a 15-25 cm axial field-of-view (FOV) and images a whole body using about six bed positions. An OpenPET geometry can extend the axial FOV with a limited number of detectors. The entire whole-body PET scanner must be able to process a large amount of data effectively. In this work, we study feasibility of the fully 3D entire whole-body PET scanner using the GATE simulation. The OpenPET has 12 block detector rings with the ring diameter of 840 mm and each block detector ring consists of 48 depth-of-interaction (DOI) detectors. The OpenPET has the axial length of 895.95 mm with five parts of 58.95 mm open gaps. The OpenPET has higher single data loss than a conventional PET scanner at grouping circuits. NECR of the OpenPET decreases by single data loss. ...
Positron emission tomography (PET) is a fully quantitative technology for imaging metabolic pathways and dynamic processes in vivo. Attenuation correction of raw PET data is a prerequisite for quantification and is typically based on separate transmission measurements. In PET/CT attenuation correction, however, is performed routinely based on the available CT transmission data. Recently, combined PET/magnetic resonance (MR) has been proposed as a viable alternative to PET/CT. Current concepts of PET/MRI do not include CT-like transmission sources and, therefore, alternative methods of PET attenuation correction must be found. This article reviews existing approaches to MR-based attenuation correction (MR-AC). Most groups have proposed MR-AC algorithms for brain PET studies and more recently also for ...
Tumour hypoxia represents a significant challenge to the curability of human tumours leading to treatment resistance and enhanced tumour progression. Tumour hypoxia can be detected by non-invasive and...Full Text Available
The introduction of positron emission tomography (PET)/magnetic resonance (MR) systems into medical practice in the foreseeable future may not only lead to a gain in clinical diagnosis compared to PET/computed tomography (CT) imaging due to the superior soft-tissue contrast of the MR technology but can also substantially reduce exposure of patients to ionizing radiation. On the other hand, there are also risks and health effects associated with the use of diagnostic MR devices that have to be considered carefully. This review article summarizes biophysical and biological aspects, which are of relevance for the assessment of health effects related to the exposure of patients to both ionizing radiation in PET and magnetic and electromagnetic fields in MR. On this basis, some considerations concerning the justification and optimization of PET/MR examinations are presented - as far as ...
Image registrations that are based on similarity measures simply adjust the parameters of an appropriate spatial transformation model until the similarity measure reaches an optimum. The numerous similarity measures that have been proposed in the past are differently sensitive to imaging modality, image content and differences in the image content, selection of the floating and target image, partial image overlap, etc. In this paper, we evaluate and compare 12 similarity measures for the rigid registration. To study the impact of different imaging modalities on the behavior of similarity measures, we have used 16 CT/MR and 6 PET/MR image pairs with known 'gold standard' registrations. The results for the PET/MR registration and for the registration of CT to both ...
Surgical resection is the only curative treatment strategy for intrahepatic cholangiocarcinoma (CC). Therefore, accurate staging is essential for appropriate management of patients with CC. We assessed the usefulness of 2-["1"8F]fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) in the staging of CC. We undertook a retrospective review of FDG PETimages in 21 patients (10 female, 11 male; mean age 57 years) diagnosed with CC. Ten patients had hilar CC and 11, peripheral CC. Patients underwent abdominal magnetic resonance imaging (MRI) (n=20) and computed tomography (CT) (n=12) for the evaluation of primary tumours, and chest radiography and whole-body bone scintigraphy for work-up of distant metastases. For semi-quantitative analysis, the maximum voxel standardised uptake value (SUV_m_a_x) was obtained from the primary tumour. All peripheral CCs showed intensely increased FDG uptake, and ...
Summation Copper-64 (T1/2?=?12.7 hours; ?+, 0.653?MeV [17.8 %]; ??, 0.579?MeV [38.4 %]) has decay characteristics that allow for positron emission tomography (PET) imaging and targeted radiotherapy of cancer. The well-established coordination chemistry of copper allows for its reaction with a wide variety of chelator systems that can potentially be linked to peptides and other biologically relevant small molecules, antibodies, proteins, and nanoparticles. The 12.7-hours half-life of 64Cu provides the flexibility to image both smaller molecules and larger, slower clearing proteins and nanoparticles. In a practical sense, the radionuclide or the 64Cu-radiopharmaceuticals can be easily shipped for PETimaging studies at sites remote to the production facility. Due to the versatility of 64Cu, ...
The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial ...
The ability to achieve tumor selective expression of therapeutic genes is an area that needs improvement for cancer gene therapy to be successful. One approach to address this is through the...Full Text Available
There is increasing evidence for an empiric link between late-life depression and Alzheimer disease (AD). The neuropathology of AD, previously only confirmed at autopsy, may now be detectable...Full Text Available
Activatable or “smart” magnetic resonance contrast agents have relaxivities that depend on environmental factors such as pH or enzymatic activity, but the MR signal depends on...Full Text Available
Colerectal cancer (CRC) is the second commonest cancer in the Western World. Successful treatment relies significantly on accurate detection and staging of primary disease as well as the early identification of the presence and extent of recurrence. Morphological imaging techniques, particularly computed tomography (CT), are well established and widely available to carry out these tasks in addition to predicting and monitoring response to therapy. This review analyses the current inadequacies for imaging CRC and critically assesses the potential role of functional imaging with positron emission tomography (PET). It was reviewed the current literature, to use the experience from the firs 1000 PET studies carried out at the institution and the perspective of surgical colleagues. It was found little evidence for the use of 2-["1"8F]fluoro-2-deoxy-D-glucose ...
The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...
Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localization of abnormalities. The resulting correlation of the anatomical and functional images may clarify the nature of the abnormality and help diagnose or stage the underlying disease. Whereas successful image fusion software has been developed for the brain, only limited success has been achieved for image alignment in other parts of the body. The development and current status of alternative approaches are presented. Dual-modality imaging is described with devices where two modalities are combined and mounted ...
Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. One key component of 4D radiotherapy planning...Full Text Available
To evaluate the role of positron emission tomography-computed tomography (PET-CT) in staging and determining early treatment response to chemotherapy in children with neuroblastoma (NB) and its correlation with the final outcome. Patients and Methods: Seventeen patients of NB with mean age of 51.5 months (age range 2-132 months; 14 males, 3 females) underwent serial "1"8F-fluorodeoxyglucose (FDG) PET-CT imaging. All 17 patients were for staging before any treatment. Twelve of 17 patients underwent "1"3"1I meta-iodobezylguanidine (MIBG) scan and bone scan. MIBG uptake was seen in the primary lesion in 11/12 patients. MIBG uptake in bones was seen in 3/12 patients. All bone lesions were concordant on MIBG and bone scan. Early response to chemotherapy was evaluated after two cycles using PET-CT. A 30% reduction in longest diameter was taken as cut-off value for response on CT based on the response ...
Cardiac disease research relies increasingly on small animal models and non-invasive imaging methods such as positron emission tomography (PET) and magnetic resonance imaging (MRI). Delayed enhancement magnetic resonance imaging (DE-MRI) using gadolinium-based contrast agents appear to be a visualizing infracted myocardium with high spatial resolution. Polar map (or bull's-eye image) was used to determination of the myocardial infarction area. Polar map is a comprehensive interpretation of the left ventricle. The infarct size was computed as the fraction of the total polar map areas. The threshold was computed as the percentage of mean intensity of the normal region. In other study, 50% predefined threshold value in varying range (30?70%) was most commonly use. However, predefined threshold value isn't acceptance in all case. The purpose of this study was to investigate ...
Introduction.Microfluidic technology allows fast reactions in a simple experimental setup, while using very low volumes and amounts of starting material. Consequently, microfluidic technology is an ideal tool for radiolabeling reactions involving short-lived positron emitters. Optimization of the complex array of different reaction conditions requires knowledge of the different reaction parameters linked to the microfluidic system as well as their influence on the radiochemical yields. 1-(5-Deoxy-5-fluoro-?-d-arabinofuranosyl)-2-nitroimidazole ([18F]FAZA) is a frequently used radiotracer for PETimaging of tumor hypoxia. The present study describes the radiosynthesis of [18F]FAZA by means of microfluidic technology and subsequent small animal PETimaging in EMT-6 tumor-bearing mice.Methods...
The production of radiopharmaceuticals used in positron emission tomography (PET) can require large amounts of activity at the start of synthesis in order to yield sufficient labeled material for clinical studies. Several investigators have developed remote and automated systems for the routine production of PET radiopharmaceuticals in order to reduce radiation exposure to personnel. Such devices, however, suffer from limited flexibility and can be relatively complicated in design. These systems are also limited to the production of a single or a few closely related compounds. Furthermore, changes in chemistry would require considerable modifications in hardware and/or software in order to bring the device back into operation. To circumvent the above limitations associated with the remote production of PET radiopharmaceuticals, the authors have investigated the use of laboratory robotics as a flexible alternative to the ...
...it only highlights the different feedstocks used in the production of fiber-based packaging materials or fossil-fuel ones; what about the energy required to convert ...feedstock, is unacceptable in trying to quantify the overall burden a specific packaging material has on the environment. As an aside, the point ... Consequentially, it is difficult to speculate on how much packaging material a company diverts from the landfill by switching from one material to another ...without specifying what geographical region said packaging material resides in. In addition, there is a lot of interest in diverting PET thermoforms from ...
To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI ...
Positron emission tomography (PET) imaging of {beta}-amyloid (A{beta}) plaques in the brain is a potentially valuable tool for studying the pathophysiology of Alzheimer's disease (AD). It may also be applicable for measuring the effectiveness of therapeutic drugs aimed at lowering A{beta} plaques in the brain. We have successfully reported a series of {sup 18}F-labeled fluoropegylated stilbenes for PETimaging studies. Encouraging results clearly demonstrated the usefulness of {sup 18}F-labeled stilbenes as potential A{beta} plaque-imaging agents. In the present study, we applied a similar approach to a styrylpyridine backbone structure. Among all derivatives examined (E)-2-(2-(2-(2-fluoroethoxy)ethoxy)ethoxy)-5-(4-dimethylaminostyryl) -pyridine (2) displayed high binding affinity in postmortem AD brain homogenates (K {sub i}=2.5{+-}0.4 nM, with [{sup 125}I]IMPY as ...
During the last decade there was a growing interest on the application of Positron Emission Tomography, PET, techniques to Breast Imaging. More recently, preliminary results suggested the use of dedicated devices to Breast Imaging using the same technique, the so-called Positron Emission Mammography cameras, PEM. In this article we review the arguments leading to a dedicated instrument. Based on these arguments we describe the concept of a PEM camera under development within the Crystal Clear Collaboration and the first results of its expected performance in terms of sensitivity and position resolution.
[F-18]FDG PET brain imaging is an accurate predictor of primary brain tumor grading and prognosis. The purpose of this study was to evaluate simplified [F-18]FDG PET metabolic indices as indicators of proliferative activity of brain tumor cells. Twenty-five patients with glioma were studied with [F-18]FDG PET. From the tissue radioactivity ratios, following tumor metabolic indices were calculated: 1) the tumor-to-whole brain ratio (T/WB), 2) the ratio of tumor-to-contralateral gray matter at the level of centrum semiovale (T/GM), 3) the ratio of tumor-to-contralateral white matter at the level of centrum semiovale (T/WM), 4) the tumor-to-ipsilateral cerebella ratio (T/iCB) and 5) the tumor-to-contralateral cerebellar ratio (T/cCB). A standardized threshold method was used to define ROIs in the tumor areas having representative metabolic activites. Correlations of the tumor metabolic indices with ...
The measurement of physiological parameters in man is possible with the help of positron emission tomography (PET) and radiopharmaceuticals labeled with short lived positron emitters as C 11, N 13, O 15 and F 18. With the use of this substances it is possible to make a tomographic map defining regional metabolic parameters in normal and diseased brain. This technique has therefore also be named 'in vivo autoradiography'. The possibility of applying C 11 or F 18 labeled deoxyglucose with PET for detecting regional and local changes in cerebral metabolic rate of glucose in brain development in children of 5 days to 1 year of age is discussed. Beyond this a relationship between cerebral metabolic rate of glucose, cerebral blood flow and cerebral metabolic rate of oxygen by use of this technique after inhalation of O 15 and C 11-labeled CO_2 is shown. Attention is drawn to the application of C 11-methyl-spiperone and PET to ...
The aim of this work is the evaluation of biodistribution and radiation dosimetry of a cocaine analog, the N-(3-iodo-prop-2E-enyl)-2beta-carbo-methoxy-3beta-(4-methyl-phenyl) nor-tropane (PE2I), labeled with carbon 11 ([{sup 11}C]PE2I). The [{sup 11}C]PE2I is a selective radioligand for imaging neuronal dopamine transporter (DAT) with positron emission tomography (PET). The DAT is a membrane-bound pre synaptically located protein that regulates the concentration of dopamine at nerve terminals. DAT radioligands are often used to evaluate the progression of Parkinson's disease or the efficiency of neuro-protective therapeutics and, typically, these studies required several successive PET scans. (author)
A beta microprobe was successfully applied to monitor arterial input function for quantification of regional cerebral blood flow (rCBF) in the monkey brain with {sup 15}O-water and positron emission tomography (PET). The sensitivity of the probe was approximately 0.83 to 1.67 cps/kBq/ml depending on the studies. A preliminary study was performed to find a suitable use and to evaluate the performance of the system and data analysis procedure. The results showed that dispersion correction of measured input function was unnecessary if microprobes were connected directly to the arterial catheter. Then multiple CBF measurements were done in three monkeys under anesthesia. Identical regions of interest were placed with the aid of magnetic resonance imaging (MRI) of each monkey and rCBF values were estimated. Estimated rCBFs were reproducible for several measurements. The mean CBF value for a pentobarbital anesthetized monkey was 46.0 ml/min/100 g ...
Quantitative metallography is often used to confirm the proper processing of aerospace metallic materials. A microstructural feature of great importance for titanium alloys processed in the alpha-beta phase field is the volume fraction of primary alpha. S...
Aim: There has been a great demand for developments of the radioligands to visualize the N-methyl-D-aspartate (NMDA) receptors by PET/SPECT. We have recently synthesized two C-11 labeled antagonists for the glycine-binding site on NMDA receptors. The aim of this work is to examine for their in vitro and in vivo binding characteristics, and to evaluate their potentials as PET radioligands for the NMDA receptors. Materials and methods: Two C-11 labeled 4-hydroxy-2-quinolones (1 and 2) were synthesized by conventional methylation of the corresponding phenols with ["1"1C]methyl iodide. In vitro and ex vivo quantitative autoradiographs with imaging plate, as well as animal PET, were employed in order to evaluate their in vitro and in vivo binding to the NMDA receptors. Results: The compound 1 showed the specific binding to rat brain slices with higher localization in the hippocampus and cerebral cortex than ...
Combination agents comprising two different pharmacophores with the same biological target have the potential to show additive or synergistic activity. Bis(thiosemicarbazonato)copper(II) complexes (e.g. 64Cu-ATSM) and nitroimidazoles (e.g. 18F-MISO) are classes of tracer used for the delineation of tumor hypoxia by positron emission tomography (PET). Three nitroimidazole-bis(thiosemicarbazonato)copper(II) conjugates were produced in order to investigate their potential as combination hypoxia imaging agents. Two were derived from the known bifunctional bis(thiosemicarbazone) H2ATSM/A and the third from the new precursor diacetyl-2-(4-N-methyl-3-thiosemicarbazone)-3-(4-N-ethylamino-3-thiosem icarbazone) - H2ATSM/en. Oxygen-dependent uptake studies were performed using the 64Cu radiolabelled ...
Radioimmunotherapy (RIT) is a new treatment option for patients with non-Hodgkin lymphoma (NHL). Response to RIT currently remains difficult to predict using conventional prognostic factors and could be refined using functional imaging. The goal of this work is to evaluate the value of 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in predicting response to Yttrium 90-labeled monoclonal antibodies for patients with NHL. Thirty-five patients with NHL who had undergone 18F-FDG PET prior to RIT with either 90Y-ibritumomab tiuxetan (group A; n=17) or 90Y-epratuzumab tetraxetan (group B; n=18) were included in this retrospective study. Four functional criteria were determined for each tumour lesion in a given patient: maximum and mean standard uptake values (SUVmax and SUVmean), functional lesion volume (LVol) and total lesion glycolysis (TLG, product of the volume and the SUVmean). For each patient, we ...
We have continued to finish up our work on analyzing relationships between elastic properties and rock microstructure. We have worked on theoretical models for the effects of sorting and packing on elastic moduli and seismic velocities. After analyzing the scanning acoustic images of shales to quantify textures at different scales, we are now using theoretical inclusion models to quantify the elastic property variation with texture. In the closing phases of this project most of our efforts are now focused on writing up the results and preparing the final reports.
To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI ...
Background: Cu-diacetyl-bis(N{sup 4}-methylthiosemicarbazone) [Cu-ATSM], although excellent for oncology applications, may not be suitable for delineating cardiovascular or neurological hypoxia. For this reason, new Cu hypoxia positron emission tomography (PET) imaging agents are being examined to search for a higher selectivity for hypoxic or ischemic tissue at higher oxygen concentrations found in these tissues. Two approaches are to increase alkylation or to replace the sulfur atoms with selenium, resulting in the formation of selenosemicarbazones. Methods: Three {sup 64}Cu-labeled selenosemicarbazone complexes were synthesized and one was screened for hypoxia selectivity in vitro using EMT-6 mouse mammary carcinoma cells. Rodent biodistribution and small animal PETimages were obtained from BALB/c mice implanted with EMT-6 tumors. One alkylated thiosemicarbazone was synthesized and examined. ...
For Monte Carlo simulations to be used as an alternative solution to perform scatter correction, accurate modelling of the scanner as well as speed is paramount. General-purpose Monte Carlo packages (Geant4, EGS, MCNP) allow a detailed description of the scanner but are not efficient at simulating voxel-based geometries (patient images). On the other hand, dedicated codes (SimSET, PETSIM) will perform well for voxel-based objects but will be poor in their capacity of simulating complex geometries such as a PET scanner. The approach adopted in this work was to couple a dedicated code (SimSET) with a general-purpose package (Geant4) to have the efficiency of the former and the capabilities of the latter. The combined SimSET+Geant4 code (SimG4) was assessed on the GE Advance PET scanner and compared to the use of SimSET only. A better description of the resolution and sensitivity of the scanner and of the scatter fraction was ...
Helical tomotherapy presented many unique dosimetric challenges and solutions during the initial commissioning process, and some of them are presented. The dose calculation algorithm is convolution/superposition based. This requires that the energy fluence spectrum and magnitude be quantified. The methodology for doing so is described. Aspects of the energy fluence characterization that are unique to tomotherapy are highlighted. Many beam characteristics can be measured automatically by an included megavoltage computed tomography imaging system. This greatly improves data collection efficiency.
Particle accelerators are constructed and operated for a wide variety of applications. In particle physics - the branch of physics that studies the elementary constituents of matter and forces between them - high energy accelerators are used to look deep into the structure of matter. Medical particle accelerators are used for example in medicine to treat tumours [31], in imaging techniques such as Positron Emission Tomography (PET) [24], or for the radio-isotopes production. They also serve in many other industrial branches, e.g. geology, radiocarbon dating [39], molecular complex spectroscopy, lithography, food preservation etc. The eld of accelerator technology draws knowledge and expertise from a wide range of scientic disciplines and uses the latest technical knowledge. The incomplete list of covered disciplines includes mathematics, physics, electronics, computing, electromagnetic eld technology, microwave technology, cryogenics, vacuum ...
This progress report covers period from Nov. 1, 1989 to Aug. 31, 1990. The long term objective was to develop receptor-binding radiotracers for SPECT or PETimaging of CNS or peripheral nervous system. The specific chemistry aims, as understood on the basis of past findings, were: to synthesize and develop a more polar analogs of 4IQNB, possessing similar binding characteristics but eliminated more rapidly from the surrounding tissues and the target organ, to design a method of introducing a technetium chelating group onto a molecule or cholinergic agent without drastic lowering of its apparent affinity, to synthesize and develop radiotracers based on m-AChR antagonists selective for one of the subtypes of the receptor. The chemistry service aims were to prepare and characterize (R,R)- and (R,S)-4IQNB and derivatives, to provide the triazene intermediate to other investigators, and to provide ({sup 123}I)4IQNB for in vivo ...
Positron emission tomography (PET) and X-ray computed tomography (CT) performed with PET/CT cameras allow us to obtain concurrently information on the presence and degree of alterations of myocardial perfusion and metabolism and on coronary arteries calcification. Furthermore, by gated myocardial perfusion studies, PET may provide crucial information on regional coronary blood flow reserve and endothelial dysfunction. A number of recent papers provide some insight on the potential of PET/CT in cardiology and in the assessment of various cardiovascular diseases including various types of vasculitis and metabolic diseases.
The central benzodiazepine receptor tracer [N-methyl-"1"1C]iomazenil (Ro 16-0154) was synthesized by alkylation of the desmethyl precursor noriomazenil with ["1"1C]methyl iodide. The ["1"1C]CH_3I (prepared by reduction of ["1"1C]CO_2 with LiAlH_4 followed by reaction with HI) was reacted with noriomazenil inN,N -dimethylformamide and Bu_4N"+OH"- for 1 min at 80 deg. C and purified by HPLC (C_1_8, 34% CH_3CN/H_2O, 7 mL/min). The product was obtained with synthesis time 35 #+-# 5 min (mean #+-# SD, n = 7), radiochemical yield (EOB) 36 #+-# 16%, radiochemical purity 99 #+-# 1%, and specific activity 5100 #+-# 2800 mCi/#mu#mol. Absorbed radiation doses were calculated from previously acquired human biodistribution data. The urinary bladder wall received the highest dose (0.099 mGy/MBq) for 4.8 h voiding interval and the effective dose equivalent was 0.015 mSv/MBq. After i.v. injection of ["1"1C]iomazenil in an adult baboon or healthy human volunteer, radioactivity accumulated in the cortex ...
Accurate modeling of system response and scatter distribution is crucial for image reconstruction in emission tomography. Monte Carlo simulations are very well suited to calculate these quantities. However, Monte Carlo simulations are also slow and many simulated counts are needed to provide a sufficiently exact estimate of the detection probabilities. In order to overcome these problems, we propose to split the simulation into two parts, the detection system and the object to be imaged (the patient). A so-called 'virtual boundary' that separates these two parts is introduced. Within the patient, particles are simulated conventionally. Whenever a photon reaches the virtual boundary, its detection probability is calculated analytically by evaluating a multi-dimensional B-spline that depends on the photon position, direction and energy. The unknown B-spline knot values that define this B-spline are fixed by a prior 'pre-' simulation that needs to ...
AIM: To investigate differential points of solid-pseudopapillary neoplasm (SPN) of the pancreas and pancreatic endocrine tumor (PET).METHODS: Ten cases of SPN and fourteen cases of PET were studied...Full Text Available
Differentiated thyroid cancer (DTC) has variable degree of F-18 FDG avidity. The purpose of this study was to evaluate the relationship between F-18 FDG uptake and pathological or immunohistochemical features of DTC. DTC patients who underwent both pre-operative F-18 FDG PET/CT scan and surgery were included in the study. Maximum standardized uptake values (SUVmax) of primary tumor were calculated. If the primary tumor showed no perceptibly increased F-18 FDG uptake, region of interest was drawn based on finding of CT portion of the PET/CT images. Pathological and immunohistochemical markers such as presence of lymph node (LN) metastasis and underlying thyroiditis, tumor size, Ki-67 labeling index, expressions of EGFR, COX-2, and Galectin-3 were evaluated. Total of 106 patients was included (102 papillary carcinomas, 4 follicular carcinomas). The mean SUVmax of the large tumors (above 1 cm) was significantly higher than the ...
The spatio-temporal dynamics of an impinging shock/boundary layer interaction at Mach 2 and under incipient separation conditions, has been investigated experimentally by means of high-speed particle image velocimetry (PIV). The available PIV acquisition rate of up to 20 kHz permits a time-resolved characterization of the interaction. The dynamics of different flow regions?notably the separation region and the reflected shock?were quantified by means of temporal auto-correlation fields and pseudo-spectral analysis. The PIV data further enable to investigate the relationship between spatially extended flow features, such as shock position and bubble size, as well as the influence of the upstream boundary layer. The results confirm earlier studies that there is an important upstream effect o...
A curved crystal X-ray spectrographs of reflection type spherical geometry was required based on the Johann scheme. Due to their high efficiency and resolution, X-ray spectrographs of focusing spectrograph spatial resolution are suitable for detecting weak X-ray spectra in spectrometers for laser fusion research. Spherically bent mica crystal with a radius of curvature of 380 mm was used in the spectrometer. The Bragg angle of the crystal analyzer was 51 degree. The image plate was employed to obtain high spatial resolution and a narrow spectral band width, with an effective area of 30 mm x 80 mm. The designed optical path of the X-ray spectrometer beam was 980 mm long from the source to the crystal and the detector. The first experiment was carried out at the 20 J energy laser facility of Research Center of Laser Fusion, China Academy of Engineering Physics. X-ray spectra in an absolute intensity scale were obtained from Al laser-produced plasmas created by laser ...
IntroductionCopper(II)-diacetyl-bis(N4-methylthiosemicarbazone), or Cu-ATSM, a hypoxia imaging agent, has been shown to be predictive of response to traditional cancer therapies in patients with a wide range of tumors. It is known that the environment of the tumor results in a myriad of physiological consequences, including hypoxia, alterations in metabolism and proliferation. In an effort to better characterize the relationships between Cu-ATSM and other prominent radiopharmaceuticals, this current study was undertaken to compare the regional distribution of 64Cu-ATSM with [18F]fluoromisonidazole (18F-FMISO), [18F]fluoro-2-deoxy-d-glucose (18F-FDG) and [18F]fluorothymidine (18F-FLT) in 9L tumors.MethodsTaking advantage of the different half-life of 18F (t1/2=110 min) in comparison to 64Cu...
Poly(ethylene terephthalate) (PET) powder from waste bottles was degraded at atmospheric pressure in 7--13 M nitric acid at 70--100 C for 72 h, to clarify the mechanism of a feed stock recycling process. Terephthalic acid (TPA) and ethylene glycol (EG) were produced by the acid-catalyzed heterogeneous hydrolysis of PET in nitric acid, and the resulting EG was simultaneously oxidized to oxalic acid. The kinetics of the hydrolysis of PET in nitric acid could be explained by a modified shrinking core model of chemical reaction control, in which the effective surface area is proportional to the degree of unreacted PET, affected by the deposition of the product TPA. The apparent rate constant was inversely proportional to particle size and to the concentration of the nitric acid. The activation energy of the reaction was 101.3 kJ/mol.
Purpose: To quantify left ventricular function derived from retrospectively ECG-gated multislice spiral CT (MSCT) data sets in comparison to MRI. Materials and Methods: In 16 patients (14 males, 2 females, mean age 56.8 #+-# 11.5 years), retrospectively ECG-gated MSCT angiography of the coronary arteries and breath-hold steady state free precession cine MRI were performed. From MSCT data-sets, 20 axial image series were reconstructed every 5% of the RR interval. Multiplanar images were reformatted in the short axis orientation from axial images. End-systolic and end-diastolic images were selected. From these images end-systolic volume (ESV), end-diastolic volume (EDV) and stroke volume (SV) as well as the ejection fraction (EF) and myocardial mass (MM) were determined using the Simpson's method and compared with MRI. Furthermore, image ...
The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of the tangential channel is around 3.10{sup ...
The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of the tangential channel is around 3.1011 ...
This work concerns the development of a methodology the objective of which is to characterize and diagnose two-phase flow regime transitions. The approach is based on the fundamental assumption that a transition flow is less stationary than a flow with an established regime. During the first time, the efforts focused on: (1) the design and construction of an experimental loop, allowing to reproduce the main horizontal two-phase flow patterns, in a stable and controlled way; (2) the design and construction of an electrical impedance probe, providing an imaged information of the spatial phase distribution in the pipe; and (3) the systematic study of the joint time-frequency and time-scale analysis methods, which permitted to define an adequate parameter quantifying the unstationarity degree. During the second time, in order to verify the fundamental assumption, a series of experiments were conducted, the objective of which was to demonstrate the ...
This work concerns the development of a methodology the objective of which is to characterize and diagnose two-phase flow regime transitions. The approach is based on the fundamental assumption that a transition flow is less stationary than a flow with an established regime. During the first time, the efforts focused on: (1) the design and construction of an experimental loop, allowing to reproduce the main horizontal two-phase flow patterns, in a stable and controlled way; (2) the design and construction of an electrical impedance probe, providing an imaged information of the spatial phase distribution in the pipe; and (3) the systematic study of the joint time-frequency and time-scale analysis methods, which permitted to define an adequate parameter quantifying the unstationarity degree. During the second time, in order to verify the fundamental assumption, a series of experiments were conducted, the objective of which was to demonstrate the ...
Both x-ray and optical cone-beam CT (CBCT) scanners are limited by scattered photons that contaminate the primary images. Transparent radiochromic gels and plastics are anticipated to produce less scattering than polymerization gels and hence result in reconstructed dose distributions with greater contrast and dynamic range. Four methods of scatter measurement were investigated to quantify scatter fractions using an in-house optical CBCT scanner. The methods consisted of generating either 'coin' shadows or primary beamlets in transmission images. The four methods generated similar results of 10% scatter fractions in gel transmission images for this particular scanner configuration with both leuco crystal violet and carbon black micelle gels. The scatter contributions were distributed as 5% from micelle gel, 2% from Teflon wall, 2% from refractive index matching liquid and 1% other ...
Grating cloaks are a variation of dielectric carpet (or ground- plane) cloaks. The latter were introduced by Li and Pendry. In contrast to the numerical work involved in the quasi-conformal carpet cloak, the refractive-index profile of a conformal grating cloak follows a closed and exact analytical form. We have previously mentioned that finite-size conformal grating cloaks may exhibit better cloaking than usual finite-size carpet cloaks. In this letter, we directly visualize their performance using photorealistic ray-tracing simulations. We employ a Newtonian approach that is advantageous compared to conventional ray tracing based on Snell's law. Furthermore, we quantify the achieved cloaking quality by computing the cross-correlations of rendered images. The cross-correlations for the grating cloak are much closer to 100% (i.e., ideal) than those for the Gaussian carpet cloak.
The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system resolution have hot been determined. The TNIF is currently being revamped to begin work ...
Flame retardant recycled PET blends containing PC and triphenyl phosphite (TPP) have been designed using the following sequential processing strategy: PET and PC are first melt blended with a transesterification catalyst, allowing the compatibilisation of the blend, before adding TPP. The presence of this last component was shown to stop the transesterification reaction between PET and PC, avoiding chain breaking. In addition, TPP acts as a chain extender of PET, allowing the average chain length to be increased. The optimized blends obtained present "V-0" UL94 rating due to a better thermal stability leading to low flammability and to the development of an important, stable and covering char layer, resulting in self-extinguishability and very low Heat Release Rates during combustion.
Ionizing radiation is a standard treatment for various human solid tumors. However, several clinical studies showed that a significant proportion of patients undergoing radiotherapy for hepatocellular carcinoma (HCC) develop intrahepatic and extrahepatic metastasis. Understanding of radiation-induced cancer cell invasiveness and behavior is essential and of great important for developing suitable treatment strategies to contain cancer spread. Therefore, in this study we evaluated the effectiveness of using swept source optical coherence tomography (SS-OCT) to monitor the enhancement of HCC cell invasiveness by radiation. SS-OCT images were acquired and recorded to obtain three-dimensional data sets per four hours in 48 hours after irradiating HepG2 cells with 7.5 Gy. The cell migration behavior in three-dimensional tissue models was quantified from images of radiation-induced and sham-irradiated cells.
Early white matter (WM) injury affects brain maturation in preterm infants as revealed by diffusion tensor imaging and volumetric magnetic resonance (MR) imaging at term postmenstrual age (PMA). The aim of the study was to assess quantitatively brain maturation in preterm infants with and without milder forms of WM damage (punctate WM lesions, PWML) using conventional MRI. Brain development was quantitatively assessed using a previously validated scoring system (total maturation score, TMS) which utilizes four parameters (progressive myelination and cortical infolding, progressive involution of glial cell migration bands and germinal matrix tissue). PWML were defined as foci of increased signal on T1-weighted images and decreased signal on T2-weighted images with no evidence of cystic degeneration. A group of 22 preterm infants with PWML at term PMA (PWML group) were compared with 22 matched controls ...
The diffusion coefficients (De) in bentonite were measured to understand and quantify the influence of groundwater chemistry such as ionic strength and to quantify the alteration of smectite mineralogical transformations. (author)
...to roam. (iv) All dogs must be on a leash when...posted. (v) We allow working a dog in refuge waters by tossing...has occurred. (f) Military, fire or emergency vehicles...prohibited. (r) Pets. Dogs and other pets, on a...
Ethanol is generally toxic to microorganisms, and intracellular and extracellular accumulation of ethanol inhibits cell growth and metabolism. In this study, pyruvate decarboxylase (pdc) and alcohol dehydrogenase (adhB) were cloned into pET-32a vector and then introduced into E. coli BL21 to produce ethanol. Heat shock genes (BEM1 and SOD2) from Saccharomyces cerevisiae were inserted into recombinant ethanolic E. coli using pET28_a vector to improve ethanol shock resistance. Three different strains were constructed: Ethanolic E. coli (adhB and pdc genes inserted using pET32_a vector), BEM1 gene-inserted E. coli (BEM1 inserted using pET_28a), and SOD2-inserted E. coli (SOD2 inserted using pET28_a). Construction of these three different strains allowed comparison of the functions of these he...
Full text: Radiotherapy treatment planning (RTP) relies heavily on medical imaging. Until recently, the most important planning tool was the treatment simulator. The kilovoltage radiographic capabilities in a treatment simulator enabled the boundaries of treatment fields to be visualized with respect to bony anatomic landmarks. Perhaps the most important advance in treatment planning in recent years is the ability to visualize the passage of the beams with respect to a more accurate geometrical representation of the tumor and other soft tissue structures. This 'virtual simulation' uses a computer-based representation of a patient to determine the extent of the disease and the location of radiation sensitive normal tissue. Computer tomographic (CT) imaging produces a high-resolution three-dimensional representation of anatomy that can be correlated with other image sets such as magnetic resonance images ...
Time-of-flight secondary ion mass spectrometry (ToF-SIMS) and laser post-ionization secondary neutral mass spectrometry (laser-SNMS) have been used to image and quantify targeted compounds, intrinsic elements and molecules with subcellular resolution in single cells of both cell cultures and tissues. Special preparation procedures for analyzing cell cultures and tissue materials were developed. Cancer cells type MeWo, incubated with boronated compounds, were sandwiched between two substrates, cryofixed, freeze-fractured and freeze-dried. Also, after injection with boronated compounds, different types of mouse tissues were extracted, prepared on a special specimen carrier and plunged with high velocity into LN{sub 2}-cooled propane for cryofixation. After trimming, these tissue blocks were freeze-dried. The measurements of the K/Na ratio demonstrated that for both cell cultures and tissue materials the special preparation techniques used were ...
Positron Emission Tomography (PET) was used to analyze in vivo antagonist binding to human myocardial muscarinic cholinergic receptor. The methiodide salt of the muscarinic antagonist, quinuclidinyl benzilate (MQNB), was labeled with the positron emitter, Carbon-11, and injected intravenously to 8 normal subjects. /sup 11/C-MQNB concentration was determined in vivo in the ventricular septum from 40 cross-sectional images acquired at the same transverse level over a period of 70 minutes. In 4 subjects, various amounts of unlabeled atropine were rapidly injected at 20 minutes to study whether atropine competitively inhibited MQNB. The kinetics of binding of /sup 11/C-MQNB were not the same in vivo and in vitro. The apparent dissociation rate of /sup 11/C-MQNB in vivo was much slower (by 1 to 2 orders of magnitude) than that observed in vitro with /sup 3/H-QNB. After atropine injection, /sup 11/C-MQNB dissociated from its binding sites at a rate ...
Technical innovations such as the availability of movable patient platforms and the introduction of 32-channel systems have made whole-body MRI for tumor staging feasible. In addition, the development of dual-modality PET/CT systems offers the opportunity to perform anatometabolic tumor staging with whole-body coverage in a single session. Based on an increase in patient survival when applying a stage-adapted therapy in different malignant diseases the relevant question relates to the accuracies of whole-body MRI and whole-body PET/CT for TNM staging. This review article addresses whole-body tumor staging with MRI and FDG-PET/CT with special emphasis on diagnostic accuracies for staging different malignant diseases. (orig.) [German] Technische Neuerungen, wie die Verfuegbarkeit beweglicher Tischaufsaetze oder die Einfuehrung von 32-Kanal-Systemen, haben die Ganzkoerperbildgebung mit der MRT ermoeglicht. Die Entwicklung ...
Nuclear medicine and magnetic resonance imaging (MRI) are widely used in cardiac diagnostics. Both techniques have been carefully evaluated and are equivalent for the assessment of regional and global wall motion as well as the evaluation of ejection fraction and cardiac volumes, though MRI is herein currently seen as gold standard. For evaluation of myocardial perfusion, extensive data exist for nuclear imaging, that, next to high diagnostic accuracy for evaluation of coronary artery disease, show incremental prognostic information and allow for independent risk stratification. Because of rapid technical advance, myocardial perfusion imaging has also become feasible with cardiac MRI. Results of recent studies are promising, but the data are few compared to perfusion scintigraphy. For viability assessment in patients with ischemic cardiomyopathy, positron emission tomography (PET) with FDG is currently ...
The influence of electron-beam irradiation on mechanical properties of commercial multilayer flexible packaging materials based on coextruded and laminated polypropylene (PP), low-density polyethylene (LDPE), ethylene vinyl alcohol copolymer (EVOH) and poly(ethylene terephthalate) (PET), irradiated with doses up to 120 kGy, was studied. The tensile strength and elongation at break of the irradiated PET/PP film increase, while the penetration and sealing resistance decreased. In addition, the irradiated PET/LDPE/EVOH/LDPE film presented increase in the tensile strength on some radiation doses and decrease of the penetration and sealing resistance, except for sealing resistance at radiation dose of 15 kGy that resulted in a slight increase of ca 4%.
The purpose of this study was to investigate whether hydroxyapatite (HAp) coating could induce polyethylene terephthalate (PET) artificial ligament graft osseointegration in the bone tunnel. Twenty-four New Zealand white rabbits underwent artificial ligament graft transplantation in bilateral proximal tibia tunnels. One limb was implanted with HAp-coated PET graft, and the contralateral limb was implanted with non-HAp-coated PET graft as control. The rabbits were randomly sacrificed at four and eight?weeks after surgery. The loads to failure of the experimental group at eight?weeks were significantly higher than those of the control group (p?=?0.0057). Histologically, application of HAp coating induced new bone formation between graft and bone at eight?weeks compared with the controls. Rea...
A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10/sup 11/ m/(m/sup 2/-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83/sup 0/C +/- 8/sup 0/C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3/sup 0/ +/- 0.1/sup 0/ thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the simultaneous iterative reconstruction technique (SIRT) and the ...
A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10"1"1 m/(m"2-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83"0C +/- 8"0C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3"0 +/- 0.1"0 thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the simultaneous iterative reconstruction technique (SIRT) and the convolution method, were ...
Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis studies diffuse infiltration is ...
The aerodynamic behavior of a vertical axis wind turbine (VAWT) is analyzed by means of 2D particle image velocimetry (PIV), focusing on the development of dynamic stall at different tip speed ratios. The VAWT has an unsteady aerodynamic behavior due to the variation with the azimuth angle {theta} of the blade's sections' angle of attack, perceived velocity and Reynolds number. The phenomenon of dynamic stall is then an inherent effect of the operation of a VAWT at low tip speed ratios, impacting both loads and power. The present work is driven by the need to understand this phenomenon, by visualizing and quantifying it, and to create a database for model validation. The experimental method uses PIV to visualize the development of the flow over the suction side of the airfoil for two different reference Reynolds numbers and three tip speed ratios in the operational regime of a small urban wind turbine. The field-of-view of the ...
Platelet deposition on bovine pericardial-tissue mitral-valve prostheses in 11 dogs was observed noninvasively by use of "1"1"1In-labeled platelets and quantified after sacrifice at one (n . 3), 14 (n . 3), and 30 (n . 5) days postimplantation (300-400 microCi of labeled platelets having been injected 24 hours previously). Thrombosis on the sewing ring and pericardial leaflets at one and 14 days and on the leaflets at 30 days was delineated in scintiphotos. In vitro quantification (% injected dose) indicated that the leaflets, sewing ring, and perivalvular tissue retained 0.904% of labeled platelets at one day postimplantation, 0.198% at 14 days, and 0.040% at 30 days. Platelet half-life was reduced to 38 hours at 21 days postimplantation but returned toward the normal (50 hours) with fibrous ingrowth in the sewing ring. Microembolism in lung and kidney, as measured by tissue/blood radioactivity ratio, also was decreased significantly at 30 days. "1"1"1In-labeled ...
The contribution of platelets and clotting factors in thrombosis on cardiovascular prostheses had been quantified with several tracers. Thrombus formation in vivo could be measured semiquantitatively in animal models and patients with indium-111, Technetium-99m labeled platelets, iodine-123, iodine-131 labeled fibrinogen, and In-111 and Tc-99m labeled antibody to the fibrinogen-receptor on the platelet- membrane, or fibrin. The early studies demonstrated that certain platelet-inhibitors, e.g. sulfinpyrazone, aspirin or aspirin- persantine increased platelet survival time with mechanical valves implanted in the baboon model and patients. Thrombus localization by imaging is possible for large thrombus on thrombogenic surface of prosthesis in the acute phase. The majority of thrombus was found in the sewing ring (Dacron) in the acute phase in both the mechanical and tissue valves. The amount of retained thrombus in both mechanical and tissue ...
The clinical management of adults with low-grade gliomas (LGGs) remains a challenge. There is no curative treatment, and management of individual patients is a matter of deciding optimal timing as well...Full Text Available
According to world statistics, dogs and cats are the species that owners most frequently seek assistance with potential poisonings, accounting 95–98% of all reported animal cases. Exposures...Full Text Available
The length polymorphism of the serotonin (5-HT) transporter gene promoter region has been implicated in altered 5-HT function and, in turn, neuropsychiatric illnesses, such as anxiety and depression....Full Text Available
Brain glucose metabolism was evaluated in four patients with acquired immunodeficiency syndrome (AIDS) dementia complex using ["1"8F]fluorodeoxyglucose (FDG) and positron emission tomography (PET) scans at the beginning of therapy with 3'-azido-2',3'-dideoxythymidine (AZT, zidovudine), and later in the course of therapy. In two patients, baseline, large focal cortical abnormalities of glucose utilization were reversed during the course of therapy. In the other two patients, the initial PET study did not reveal pronounced focal alterations, while the post-treatment scans showed markedly increased cortical glucose metabolism. The improved cortical glucose utilization was accompanied in all patients by immunologic and neurologic improvement. PET-FDG studies can detect cortical metabolic abnormalities associated with AIDS dementia complex, and may be used to monitor the metabolic improvement in response to AZT treatment.
We report on a high resolution, monolithic crystal PET detector design concept that provides depth of interaction (DOI) positioning within the crystal. Our design utilizes a novel sensor on...Full Text Available
In cases of obstructive colorectal cancer (CRC), preoperative diagnosis of the proximal lesion is often difficult when the primary lesion impedes the passage of the endoscope. The aim of this study was to evaluate the usefulness of fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) in such cases. A total of 52 obstructive CRC patients who underwent preoperative FDG-PET and subsequent surgical resection were retrospectively reviewed. The correlation between characteristics of the proximal lesion and FDG-PET findings was analyzed statistically. There was a significant correlation between the proximal lesion size and the maximum standardized uptake value (P=0.00016). Abnormal FDG accumulation in the proximal colon indicated the existence of proximal cancer or adenoma with a sensitivity of 50% and a specificity of 100%. There was a significant difference in the distribution of tumor size between the cases ...
"1"8F-fluorodeoxyglucose (FDG) uptake on positron emission tomography (PET) scan has been found to reflect tumor aggressiveness and prognosis in various types of cancer. However, pattern of FDG uptake in biliary malignancies and its clinical significance have not been studied well. The purpose of this study was to assess the additional value of "1"8F-FDG PET in differential diagnosis and prognosis of cholangiocarcinoma (CC) according to the tumor location and tumor morphology. From April 2005 to May 2008, eighty two patients (M:F=55:27, age 66.2#+-#9.6 yrs) with CC underwent "1"8F-FDG PET. For semiquantitative analysis, the maximum standardized uptake value (SUV_m_a_x) was obtained from the primary tumor. The difference of SUV_m_a_x according to the tumor location and tumor growth pattern, such as scirrhous type, nodular type, polypoid type were compared. Overall sensitivity of PET scan was 81.7% in CC. ...
Purpose: The predictive potential of tumor cell kinetic parameters may be improved when they are studied in relation to other microenvironmental parameters. The purpose of this investigation was to quantitatively categorize human tumor samples according to proliferation patterns. Second, it was examined whether these characteristics are retained after xenotransplantation. Methods and Materials: Fifty tumor samples from head-and-neck cancer patients were immunohistochemically stained for Ki-67 and vessels. Also, parts of the samples were transplanted into nude mice. Tumors were categorized according to previously described patterns of proliferation. Vascular and proliferation patterns were analyzed using an image processing system. Results: The 50 tumors were categorized into four patterns of proliferation by visual assessment: marginal (6), intermediate (10), random (21), and mixed (12). One tumor could not be classified. These patterns were ...
An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)
The electrical conductivity of ion-implanted films of Nylon 66, Polypropylene (PP), Poly(tetrafluoroethylene) (Teflon) and mainly Poly (ethylene terephthalate) (PET) was determined by DC measurements at voltages up to 4500 V and compared with the corresponding values of pristine films. Measurements were made at 21/sup 0/C +/- 1/sup 0/C and 65 +/- 2% RH. The electrical conductivity of PET films implanted with F/sup +/, Ar/sup +/, or As/sup +/ ions at energies of 50 keV increases by seven orders of magnitude as the fluence increases from 1 x 10/sup 18/ to 1 x 10/sup 20/ ions/m/sup 2/. The conductivity of films implanted with As/sup +/ was approximately one order greater than those implanted with Ar/sup +/, which in turn was approximately one-half order greater than those implanted with F/sup +/. The conductivity of the most conductive film approx.1 S/m) was almost 14 orders of magnitude greater than the pristine PET film. ...
L-[3-"1"8F]-#alpha#-methyltyrosine ("1"8F-FMT) is an amino-acid tracer for positron-emission tomography (PET). We have conducted a clinicopathologic study to elucidate the correlation of angiogenesis with "1"8F-FMT and 2-["1"8F]-fluoro-2-deoxy-D-glucose ("1"8F-FDG) uptake in patients with non-small cell lung cancer (NSCLC). Thirty-seven NSCLC patients were enrolled in this study, and two PET studies with "1"8F-FMT and "1"8F-FDG were performed. Uptake of PET tracers was evaluated with standardized uptake value. Vascular endothelial growth factor (VEGF), CD31, CD34, L-type amino acid transporter 1 (LAT1) and Ki-67 labeling index of the resected tumors were analyzed by immunohistochemical staining, and correlated with the clinicopathologic variables and the uptake of PET tracers. The median VEGF rate was 45% (range, 10-78%). High expression was seen in 30 patients (81%, 30/37). VEGF expression was ...
The ultrafine fibers based on the composites of polyethylene terephthalate (PET) and a series of fatty acids, lauric acid (LA), myristic acid (MA), palmitic acid (PA), and stearic acid (SA), were prepared successfully via electrospinning as form-stable phase change materials (PCMs). The morphology and thermal properties of the composite fibers were studied by field emission scanning electron microscopy (FE-SEM) and differential scanning calorimetry (DSC), respectively. It was found that the average fiber diameter increased generally with the content of fatty acid (LA) in the LA/PET composite fibers. The fibers with the low mass ratio maintained cylindrical shape with smooth surface while the quality became worse when the mass ratio is too high (more than 100/100). Moreover, the latent heat of the composite fibers increased with the increase of LA content and the phase transition temperature of the fibers have no obvious variations compared with ...
There are few studies that focused on the prognostic value of FDG-PET on small cell lung cancer (SCLC). Not only FDG uptake (maxSUV), but also metabolic size (greatest dimension of PET positive mass) may determine the prognosis of SCLC. Here, we investigated the prognostic significance of maxSUV, and the metabolic size in SCLC patients. Biopsy-proven SCLC patients (n=21; age, means.d.=67.39y; male: female=19: 3) who had underwent FDG-PET within 4 weeks of chemotherapy initiation were enrolled. There were 7 extensive disease (ED) and 14 limited disease (LD) patients. The maxSUV and the metabolic size were measured, and then, size-incorporated maxSUV (SIMaxSUV = maxSUV x metabolic size) were calculated at individual SCLC masses. SIMaxSUV of main lesion (main-SIMaxSUV), and the summed value of SIMaxSUV of all PET positive masses (summed-SIMaxSUV) were obtained. In addition, age, stage, and %expression of ...
Rationale Receptor occupancy study has been performed to evaluate pharmacokinetic profiles in new antipsychotic drug development. While these findings highlight the value of positron emission tomography (PET) for dose-finding study, what is unclear is if it is necessary to conduct these studies in patients with schizophrenia or whether studies in healthy volunteers are adequate. Objectives To determine if it is necessary to conduct dopamine receptor occupancy studies in patients with schizophrenia or whether studies in healthy volunteers are adequate for dose-finding study, we compared the concentration?occupancy relationship in terms of EC50 between patients and healthy volunteers. Methods Ten healthy volunteers and eight patients with schizophrenia participated in the study. We measured ...
In this study, Nylon 66/Polyester (Ny 66/PET) hybrid cord design and production was investigated to obtain new cord with better performance than conventional cord. The factors affecting cord properties and cord production process were examined. Taguchi design of experiment method was implemented in order to minimize the required number of experiments. Different sets of 4 reference cords conventionally used in tyre industry were prepared and resorcinol-formaldehyde-latex (RFL) treated in order to make a comparison of performance. Mechanical and thermal properties of hybrid cords were measured and compared with the values of reference cords. It was found that the twist level of high modulus PET component in the hybrid cords should be the same or above of the nylon in order to obtain maximum ...
A new technique for ion implantation into concave surface of insulating materials is proposed and experimentally studied. The principle is roughly described by referring to modifying inner surface of a PET (polyethylene terephthalate) bottle. An electrode that is supplied with positive high-voltage pulses is inserted into the bottle. Both plasma formation and ion implantation are simultaneously realized by the same high-voltage pulses. Ion sheath with a certain thickness that depends on plasma parameters is formed just on the inner surface of the bottle. Since the plasma potential is very close to that of the electrode, ions from the plasma are accelerated in the sheath and implanted perpendicularly into the bottle's inner surface. Laser Raman spectroscopy shows that the inner surface of an ion-implanted PET bottle is modified into DLC (diamond-like carbon). Gas permeation measurement shows that gas-barrier property enhances due to the ...
The authors used studies of local cerebral metabolic rate for glucose (LCMRGlc) to examine development of cerebral organization in 5 days to 1 year old children. A group (n=8) of infants with diverse pediatric disorders allowed investigation of developmental changes in LCMRGlc, while also providing relevant clinical management information. Patients consisted of questionable and definite neonatal seizures, cerebral embolism from cardiac sources, and otherwise normal infants with facial nevi with consideration of Sturge-Weber. Gradual increase in cortical LCMRGlc coincides with suppression of intrinsic subcortical reflexes present in all newborns. Two retarded children (2 years old) showed LCMRGlc developmental patterns of a few days old, which corresponded to their functional and mental status. These studies illustrate great potential of PET to study normal and altered states of human brain development.
... Title : Optical Images Due to Lenses and Mirrors. ... Abstract : The properties of real and virtual images formed by lenses and mirrors are reviewed. ...
Purpose: Three-dimensional rotational angiography (3DRA) is a new technique based on a rotational angiographic acquisition able to display arterial vessels in a 3D rendering mode. The system was mainly developed for neuroradiological evaluations but preliminary extracranial experiences have also been reported. The aim of our work was to compare the results of three-dimensional angiography of the carotid arteries done with high-flow injection of contrast medium from the aortic arch with the results of selective angiography. Materials and methods: Twenty patients underwent digital angiography of the supra-aortic vessels in order to quantify a stenosis of the carotid bifurcations previously detected at Doppler Ultrasound. Examinations were performed with the Philips Integris Allura system provided with the rotational angiography (RA) tool connected to a workstation for three-dimensional reconstruction able to display vessels in a 3D fashion (Volume Rendering, Shaded ...
Polycyclic aromatic hydrocarbons (PAHs) are combustion products of organic materials, mixtures of which contain multiple known and probable human carcinogens. PAHs occur in indoor and outdoor air, as well as in char-broiled meats and fish. Human exposure to PAHs occurs by inhalation, ingestion and topical absorption, and subsequently formed metabolites are either rendered hydrophilic and excreted, or bioactivated and bound to cellular macromolecules. The formation of PAH-DNA adducts (DNA binding products), considered a necessary step in PAH-initiated carcinogenesis, has been widely studied in experimental models and has been documented in human tissues. This review describes immunohistochemistry (IHC) studies, which reveal localization of PAH-DNA adducts in human tissues, and semi-quantify PAH-DNA adduct levels using the Automated Cellular Imaging System (ACIS). These studies have shown that PAH-DNA adducts concentrate in: basal and supra-basal ...
The blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) signal response to neural stimulation is influenced by many factors that are unrelated to the stimulus. These factors are physiological, such as the resting venous cerebral blood volume (CBV(v)) and vessel size, as well as experimental, such as pulse sequence and static magnetic field strength (B(0)). Thus, it is difficult to compare task-induced fMRI signals across subjects, field strengths, and pulse sequences. This problem can be overcome by normalizing the neural activity-induced BOLD fMRI response by a global hypercapnia-induced BOLD signal. To demonstrate the effectiveness of the BOLD normalization approach, gradient-echo BOLD fMRI at 1.5, 4, and 7 T and spin-echo BOLD fMRI at 4 T were performed in human subjects. For neural stimulation, subjects performed sequential finger movements at 2 Hz, while for global stimulation, subjects breathed a 5% CO(2) gas mixture. Under ...
The steam generator (SG) is one of the most critical components of the heat transfer system in nuclear generation stations. Testing the structural integrity of SG tubing and SG internals is a key element of the fitness-for-service assessments to assure the safe and continuous operation of nuclear power plants. Recent eddy current (ET) inspections of two nuclear power plants revealed degradation of some of the tube support plate (TSP) structures, which was also confirmed by visual inspection. The phenomena was described as metal loss, caused by flow-accelerated corrosion of the carbon steel trefoil support plate and varying from minor to complete loss of the ligaments. This loss of TSP ligaments results in lack of support for the adjacent tubes making them more susceptible to fretting-wear damage and fatigue cracking. A signal analysis method, based on the responses at low frequency of two types of eddy current probes, has been developed to assess the degree of degradation. The standard ...
A large part of mechanical and durability characteristics of cement-based materials comes from the performances of the hydrated cement, cohesive matrix surrounding the granular skeleton. Experimental studies, in situ or in laboratory, associated to models, have notably enhanced knowledge on the cement material and led to adapted formulations to specific applications or particularly aggressive environments. Nevertheless, these models, developed for precise cases, do not permit to specifically conclude for other experimental conclusions. To extend its applicability domain, we propose a new evolutive approach, based on reactive transport expressed at the microstructure scale of the cement. In a general point of view, the evolution of the solid compounds of the cement matrix, by dissolutions or precipitations, during chemical aggressions can be related to the pore solution evolution, and this one relied to the ionic exchanges with the external environment. By the utilization of a ...
The purpose of this paper is to report the personal experience with helical CT evaluation of hepatocellular carcinoma treated with various percutaneous interventional procedures. From December 1996 to September 1998 it were examined with helical CT 41 patients (73 nodules in all) with hepatocellular carcinoma treated with percutaneous ablation therapies: conventional ethanol injection in 18 subjects (31 nodules), one-shot ethanol injection 3 (8 nodules), radiofrequency thermal ablation in 16 (25 nodules), and combined chemo embolization and ethanol injection in 4 (9 nodules). CT performed was 4-27 days after the last session, acquiring biphasic volumetric images in 14 patients and triphasic volumetric images in 27. A second treatment with subsequent CT study was performed for 28 lesions; 15 underwent 3 serial studies and 6 underwent 4 studies. Compared with pretreatment findings, the diameter was unchanged in 62% of the nodules and increased in ...
Dust detection and control in real time, represent one of the most challenging problem in all those environments where fine and ultrafine airborne particulate solids products are present. The presence of such products can be linked to several factors, often directly related and influenced by the working-production actions performed. Independently from the causes generating dust, airborne contaminants are an occupational problem of increasing interest as they are related to a wide number of diseases. In particular, airborne dusts are well known to be associated with several classical occupational lung diseases, such as the pneumoconiosis, especially at high levels of exposure. Nowadays there is also an increasing interest in other dust related diseases, from the most serious as cancer and asthma, to those related with allergies or irritation and other illnesses, also occurring at lower levels of exposure. Among the different critical factors influencing health risk for airborne dust ...
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm{sup -3} or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the end application itself ...
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm"-"3 or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the end application itself set ...
Aim: Today, MRI is an integral part of the presurgical evaluation of patients suffering from partial epilepsy. These patients frequently show focal morphological abnormalities with potential epileptogenic character and surgical resection of these lesions is associated with superior postsurgical outcome as to seizure frequency. Apart from easily detectable defects, such as post-traumatic lesions or cerebral infarction, as wide variety of mainly small abnormalities can be detected using MRI. Methods: In this study, 484 patients suffering from partial epilepsy of temporal or frontal onset were evaluated for the incidence of different lesions in this population. Results: All lesions found were included without evaluating their potential epileptogenicity, which remains to be proven using other procedures (EEG, SPECT, PET, etc.). Involvement of the hippocampal formation was a major finding in temporal lobe epilepsy, which could be detected as sclerosis ...
BackgroundBrucellosis is a zoonosis of veterinary, public health and economic significance in most developing countries. Human brucellosis is a severely debilitating disease that...Full Text Available
the revealed stage of T Tauri star evolution, is only a mere shadow of its former self. Once primary accretion starts, one has the (poorly quantified) ...
The study design included an in vivo laboratory study. The objective of the study is to quantify the kinematics of the lumbar spinous processes in asymptomatic patients during un-restricted functional...Full Text Available
Translocator protein (TSPO) is upregulated in activated microglia and thus can serve as a marker of neuroinflammation. Recently, a novel radioligand, 11C-N,N-diethyl-2-[2-(4-methoxyphenyl)-5,7-dimethyl-pyrazolo[1,5-a]pyrimidin-3-yl]-acetamide...Full Text Available
Authors describe diagnostic dilemma of differentiating pyelonephritis with lymphomatous involvement of kidney in a known case of lymphoma. FDG uptake pattern was non-discriminatory and pyelonephritis diagnosed retrospectively on follow up study. Authors emphasize the importance of recognition of features and subtle clues of infection evident on CT component of PET-CT. (author)
Research is described in the development of organometallic reagents in which the boron was attached to a nonreactive organic or inorganic matrix such as polystyrene, silica, or alumina. We developed the synthesis of oxygen-15 labelled butanol, which has been found to be a valuable blood flow agent in humans. We have also developed a series of polymeric borane derivatives which were used to prepare nitrogen-13 labelled amines.
Resistance to the extended-spectrum cephalosporins can occur in Salmonella species via the production of extended-spectrum and AmpC β-lactamases. We describe human infections...Full Text Available
Image enhancement is of great importance in medical imaging where image resolution remains a crucial point in many image analysis algorithms. In this paper, we investigate brain hallucination...Full Text Available
Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis ...
Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...
Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...
Background/Objectives:Imaging technology is an important part of the diagnosis and management of spinal trauma. Indications and findings in post-traumatic imaging of the vertebral...Full Text Available
performs Gaussian pyramid operation on an image performs expand pyramid operation on an image mosaic two images using 'reduce' and 'expand' pyramid ...
This report describes the design of, and image reconstruction capacity of a Hadamard Raman Microscopic imager. Microscopy of benzoic acid and graphite electrodes, as well as electrophoretic blotting, are described. (CBS)
The MISR instrument aboard NASA's Terra satellite participated in the UAE-2 campaign, August-October 2004. This campaign represented a unique opportunity to study the complex aerosol situation in the Arabian Gulf region, in the context of a first-rate collection of aircraft and surface-based instruments, giving us the opportunity to do some groundbreaking satellite aerosol validation work. We aimed (1) to validate MISR aerosol retrieval results for dust and pollution particles over dark and light surfaces, and (2) to contribute regional maps of aerosol optical thickness (AOT) and particle micro-physical properties, giving spatial context to the field-instrument measurements, and moving toward a satellite-based regional aerosol climatology. The validation effort benefited from the combination of an instrumented aircraft and a regional network of surface-based sun photometers. We obtained high-quality sub-orbital data coincident with MISR overpasses on three days: September 01, 10, and ...
The effects of gamma and e-beam irradiation on mechanical and structural properties of nylon 66 (Ny 66), nylon 6 (Ny 6) and poly(ethylene terephthalate) (PET) fabrics used in tyres were investigated. The untreated (greige), treated cords and calendered fabrics were irradiated at different doses. It is found that the effects of high energy irradiation on greige, treated cords and calendered fabrics are similar. No protective effect of compounds used in calendering was observed against radiation-induced oxidative degradation. The deterioration effect of gamma irradiation on mechanical properties is much higher than that of e-beam irradiation for all types of samples. Limiting viscosity numbers of both gamma and e-beam irradiated nylon 6 and nylon 66 cords were found to decrease with increasing dose. It is concluded that PET calendered fabric has higher resistance to ionizing radiation. Ny 6 and Ny 66 calendered fabrics are more sensitive even at ...
The first preparation and characterization of the platinum (II) complexes containing five phosphorus ligands are reported herein. The complexes are represented by the formulae (Pt(PP/sub 3/)(P(OR)/sub 3/)Cl/sub 2/, where R = Me or Et, and (Pt(PP/sub 3/)(PEt/sub 3/))Cl/sub 2/. The /sup 31/P spectra of the complexes are presented. 10 references, 2 tables.
A new coumarin-based sensor molecule (L1) has been synthesized and this was found to bind calcium and magnesium ions more effectively as compared to other alkali/alkaline earth/lanthanide and certain transition metal ions. A significant enhancement in fluorescence intensity was observed on binding to Ca2+ and Mg2+ ions; while a minor quenching was observed for weakly bound Hg2+, Ni2+, Fe3+, and Co2+ ions. PET process, coupled with the ICT process, is proposed to explain the observed spectral response.
We have measured the frequency-dependent dielectric function of semi-crystalline polybutylene terephthalate (PBT) in the terahertz region between 100?GHz and approximately 2.8?THz. A characteristic band is observed around 2.38?THz. The intensity of this band is a good indicator of the degree of crystallinity of the different samples. A potential assignment of this band is proposed, based on the comparison with spectroscopic data of the structurally very similar polyethylene terephtalate (PET). Furthermore, the frequency-dependent index of refraction of PBT reveals more insight about the morphology and different thermal history of the samples under investigation.
We propose new method of assessment of histological images for medical diagnostics. 2-D image is preprocessed to form 1-D landscapes or 1-D signature of the image contour and then their complexity is...Full Text Available
In vivo two-photon imaging through the pupil of the primate eye has the potential to become a useful tool for functional imaging of the retina. Two-photon excited fluorescence images...Full Text Available
This paper describes Image Engine, an object-oriented, microcomputer-based, multimedia database designed to facilitate the storage and retrieval of digitized biomedical still images, video, and text...Full Text Available
Adaptive image processing is one of the most important techniques in visual information processing, especially in early vision such as image restoration, filtering, enhancement, and segmentation. This work focuses on applications of advanced CI techniques in image processing applications
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...
Modeling artificial scanning electron microscope (SEM) and scanning ion microscope images has recently become important. This is because of the need to provide repeatable images with a priori determined parameters. Modeled artificial images are highly useful in the evaluation of new imaging and metrological techniques, like image-sharpness calculation, or drift-corrected image composition (DCIC). Originally, the NIST-developed artificial image generator was designed only to produce the SEM images of gold-on-carbon resolution sample for image-sharpness evaluation. Since then, the new improved version of the software was written in C++ programming language and is in the Public Domain. The current version of the software can generate arbitrary samples, any drift function, and many other features. This ...
The aim of the safety calculation is to quantify through numerical modelling the radiological impact (molar flow, human dose) of a potential repository for radioactive waste on the Meuse/Haute Marne site at Bure. A selection process is underway for safety scenarios and their phenomenological and numerical conceptual models upstream from the safety calculation. This involves defining and quantifying the geometric and dimensional representations of the repository for each scenario plus the physical, mathematical and numerical models that reflect its behaviour and the uncertainties associated with all the parameters required to quantify the impact. A summary will be given of these various aspects. The numerical simulations are then performed on the Alliances platform which integrates the various computer codes required for the physical representation of the system. (authors)
Background: Quantifying HIV levels in mucosal secretions is essential to study compartmentalized expression of HIV and facilitate development of intervention strategies to prevent disease progression and transmission. Objectives: To develop a sensitive, reliable, and cost-effective technique to quantify HIV from blood and vaginal secretions that is compatible with efficient implementation in clinical research environments. Study design: A sensitive, reliable, internally-controlled real-time reverse transcriptase (RT) PCR assay, which uses the HIV-1 pol gene as a target (Hpol assay) was developed to quantify HIV levels in plasma and genital secretions, and compared to the widely used Roche Amplicor(TM) HIV-1 Monitor assay. In addition, a simplified method of sample collection and processing...
Air toxics from the industrial wastewater treatment plants (IWTPs) impose serious health concerns on its surrounding residential neighborhoods. To address such health concerns, one of the key challenges is to quantify the air emissions from the IWTPs. The objective here is to characterize the air emissions from the IWTPs and quantify its associated uncertainty. An IWTP receiving the wastewaters from an airplane maintenance facility is used for illustration with focus on the quantification of air emissions for benzyl alcohol, phenol, methylene chloride, 2-butanone, and acetone. Two general fate models, i.e., WATER9 and TOXCHEM+V3.0 were used to model the IWTP and quantify the air emissions. Monte Carlo and Bootstrap simulation were used for uncertainty analysis. On average, air emissions fr...
The Subcommittee for Surveillance of Nuclear Medicine Practice has implemented a survey for actual nuclear medicine practice in Japan every 5 years. This article reports on the third survey implemented during a one-month period in June 1992. Questionnaires were sent to all 1256 facilities employing radiopharmaceuticals in routine practice, and 1162 (92.5%) answered. In vivo nuclear medicine examinations per day were performed in 6600 cases. SPECT accounted for 19.4%, as compared with 7.1% in the 1987 survey. According to organs, the frequency of examination for the cerebrospinal region was 3.2 and 2.2 times higher than that in the 1982 and 1987 surveys, respectively, whereas for the thyroid gland it was 0.6-fold and 0.7-fold that of these surveys. The proportion of bone scintigraphy was the highest (24.5%), followed by tumor scintigraphy (14.1%) and myocardial scintigraphy (11.9%). The frequency of myocardial and cerebral blood flow scintigraphy was dramatically increased as compared ...
A major factor for the achievement of the desirable performance, efficiency and lifetime of flexible organic electronic devices is the optimization of the encapsulation layers that protect the device active layers by atmospheric gas molecule permeation. The active layers consisted of small molecule and/or polymer organic semiconductors as well as the organic conductors need to be encapsulated into a transparent medium that will provide the necessary protection and maintain their charge generation and transport characteristics. The encapsulation layers are generally consisted of inorganic thin films (silicon oxide-SiO{sub x} and aluminium oxide-AlO{sub x}) deposited onto the polymeric substrates, such as PolyEthylene Terephthalate (PET). In this work, in situ and real-time Spectroscopic Ellipsometry in the ultraviolet spectral region has been implemented in order to investigate the growth of inorganic SiO{sub x} and AlO{sub x} nano-layers onto ...
This support document summarized the results of botanical surveys conducted as part of a phytoremediation research project that catalogued plants found growing at a petroleum impacted site in Alberta. Phytoremediation refers to the growing of chosen plant species in a polluted site for a period of time in order for the plant to remove contaminants through its natural attributes of absorption, translocation, storage and excretion. Several different plant species with phytoremediation properties are being considered for wide scale bioremediation use. This document described the PhytoPet database which was originally developed as an inventory of plants with phytoremediation capabilities. It was designed to provide easy access to information and help users choose plants with the potential to phytoremediate petroleum hydrocarbons. The information in this document is intended for remediation specialists, site owners and managers as well as environmental scientists in ...
Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula
Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula.
A diverse set of digital image-processing applications exists at the Lawrence Livermore National Laboratory. While many of these include some sort of image analysis or restoration, virtually all of them require image-enhancement procedures. In this paper we describe the principal image-processing facility at the Laboratory, followed by a discussion of several of the major image-processing application areas.
Vulnerability to xylem embolism by freeze-thaw cycles and water stress was quantified in ring-porous (Quercus gambelii Nutt.), diffuse-porous (Populus tremuloides Michx.,...Full Text Available
Variability in motor performance decreases with practice but is never entirely eliminated, due in part to inherent motor noise. The present study develops a method that quantifies how performers...Full Text Available
A regional analysis of nucleotide substitution rates along human genes and their flanking regions allows us to quantify the effect of mutational mechanisms associated with transcription in germ line...Full Text Available
The interactions between biochemical processes and mechanical signaling play important roles during various cellular processes such as wound healing, embryogenesis, metastasis, and cell migration. While...Full Text Available
BackgroundIn Africa low birth weight (LBW) (<2500 g), is the strongest determinant of infant morbidity and mortality. The aim of this study was to quantify the effect of...Full Text Available
ObjectiveTo investigate and to quantify the relationship between hospital costs and health outcomes for patients with acute myocardial infarction (AMI) in Veterans Health Administration...Full Text Available
BackgroundSmall laboratory fish share many anatomical and histological characteristics with other vertebrates, yet can be maintained in large numbers at low cost for lifetime studies....Full Text Available
We quantified antibody responses to the HCV proteome that are associated with sustained virologic response (SVR) in HIV/HCV co-infected patients treated with pegylated interferon and ribavirin....Full Text Available
BackgroundConducted as part of the Urologic Diseases in America project whose aim was to quantify the burden of urologic diseases on the American public, this study focuses on Veterans...Full Text Available
Acoustic pharyngometry is a relatively new noninvasive method that quantifies geometrically complexed pharyngeal dimensions. Our study aimed to investigate the predictability and usefulness of acoustic...Full Text Available
School buses contribute substantially to childhood air pollution exposures yet they are rarely quantified in epidemiology studies. This paper characterizes fine particulate matter (PM2.5)...Full Text Available
The objectives of this study were to evaluate the current fitness of an area ambulance service based in Belfast and to quantify the physiological demands of accident and emergency work. From a total...Full Text Available
This study investigated weathering effects on polyvinyl chloride (PVC) based wood plastic composites (WPC), with a focus on the color and structure that is attributed to the material composition. It is directed towards quantifying the main chemical modifi...
The concentration of some organic acids in the atmosphere was determined using a wet effluent diffusion denuder-aerosol collector coupled with Ion Chromatography. Three organic acids and four inorganic anions were identified and quantified in the air sample, taken from the backyard of PSI. (author)
Spinal cord injury (SCI) is a debilitating disorder, which produces profound deficits in volitional motor control. Following medical stabilization, recovery from SCI typically involves long term rehabilitation....Full Text Available
This dissertation presents the development of the novel mechanical testing technique of in situ nanoindentation in a transmission electron microscope (TEM). This technique makes it possible to simultaneously observe and quantify the mechanical behavior of nano-scale volumes of solids.
Genetic effects on mechanical properties have been demonstrated in rodents, but not confirmed in primates. Our aim was to quantify the proportion of variation in vertebral trabecular bone mechanical...Full Text Available
The method of linear analogue self-assessment (LASA) was used to quantify the views concerning day care which were held by patients attending a geriatric day hospital. The results suggest that day hospitals...Full Text Available
Many patients are currently suffering from nickel (Ni)-induced allergic contact dermatitis (ACD). There have been few Korean studies dealing with the threshold of Ni-induced ACD and quantifying the...Full Text Available
BackgroundEpidemiologic studies associate lung cancer in non-smoking Chinese women with Chinese-style wok cooking. Our goal was to quantify carcinogen and toxicant...Full Text Available
Pseudomonas mandelii liquid cultures were studied to determine the effect of pH and temperature on denitrification gene expression, which was quantified by quantitative reverse transcription-PCR....Full Text Available
Nursing infants may be exposed to lead from breast milk, but relatively few data exist with which to evaluate and quantify this relationship. This route of exposure constitutes a potential infant hazard...Full Text Available
The utility of a two-photon optical fiber fluorescence probe (TPOFF) for sensing and quantifying tumor fluorescent signals was tested in vivo. Xenograft tumors were developed in athymic mice using MCA207...Full Text Available
As part of an investigation of the mechanisms of coastal change in the Carolinas (http://woodshole.er.usgs.gov/project-pages/cccp/index.html), instrumented tripods were deployed on Diamond Shoals near Cape Hatteras, NC. These tripods recorded data quantifying the currents, waves, turbidity, temperat...
There is limited information about the true incidence of acute renal failure (ARF). Most studies could not quantify disease frequency in the general population as they are hospital-based and...Full Text Available
BackgroundKinematic and kinetic measurements used in laboratory settings can quantify upper extremity movement impairment following stroke, but their relationship...Full Text Available
BackgroundThe aim of this cohort study was to quantify the effect of alcohol in the risk of oral cancer in different strata of folate intake, controlling for known...Full Text Available
The objectives of this study were to quantify the effect of 16 ppm of dietary monensin on milk production and composition of dairy cows, and to investigate factors having a potential impact on this...Full Text Available
The present research scholars are having keen interest in doing their research activities in the area of Data mining all over the world. Especially, [13]Mining Image data is the one of the essential features in this present scenario since image data plays vital role in every aspect of the system such as business for marketing, hospital for surgery, engineering for construction, Web for publication and so on. The other area in the Image mining system is the Content-Based Image Retrieval (CBIR) which performs retrieval based on the similarity defined in terms of extracted features with more objectiveness. The drawback in CBIR is the features of the query image alone are considered. Hence, a new technique called Image retrieval based on optimum clusters is proposed for improving user interaction with image retrieval systems by fully exploiting ...
Werner states are paradigmatic examples of quantum states and play an innovative role in quantum information theory. In investigating the correlating capability of Werner states, we find the curious phenomenon that quantum correlations, as quantified by the entanglement of formation, may exceed the total correlations, as measured by the quantum mutual information. Consequently, though the entanglement of formation is so widely used in quantifying entanglement, it cannot be interpreted as a consistent measure of quantum correlations per se if we accept the folklore that total correlations are measured (or rather upper bounded) by the quantum mutual information.
A generalised procedure for quantifying the benefits of household biogas plants is presented. The sensitivity of the procedure to the uncertainty in input prices is reduced through the assumption of incremental benefits from the biogas plant. These benefits are quantified in terms of the quantity of fuelwood for which the biogas substitutes in cooking, the quantity of kerosene replaced through the use of biogas for lighting and the diesel fuel displaced through the use of a biogas fuelled dual-fuel engine for motive power. Sensitivity of the monetary benefits for these parameters is examined in order to identify variables which influence the viability of the technology to the end user. (author).
For many years, {beta} radioactivity has been used to label molecules and follow them in various biological processes. {beta} imaging is obtained by autoradiography. Classically made on films or on photographic emulsions, autoradiography is now supplanted by radio-imagers which are very performing. The phosphor-imager, {beta}-imager and {mu}-imager are the systems mainly used today and their operating principles and properties are compared. The great advantages of these imagers are: their rapidity to obtain results and their reliability for absolute quantification. All emitters ({beta}{sup -}, {beta}{sup -} -{gamma} and {beta}{sup +}) are detectable as well as the gamma emitters of nuclear medicine, by means of their low energy electrons ejected during y emission. Phosphor-imager is well suited to energetic tracers and large series of ...
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...
Two geriatic male rhesus monkeys were used for the radioisotope imaging in this research. Discussion of the radionuclide, materials, and method used to accomplish the neurologic examination and the results obtained, both during the procedure and confirmation of the results by necropsies were accompanied by color photos of scan images. Results were that the nuclear images provided accurate images of intracranial neoplasia.
Computed radiography (CR) systems use a photostimulable phosphor plate enclosed in a cassette. In CR, image acquisition is a two-stage process wherein image capture and image read out are done separately. Direct digital radiography (DR) systems, on the other hand, use detectors that have a combined image capture and image read out capability. DR systems are also called as DDR or ddR systems by some vendors. This article focuses on DR systems
This paper examines the seismic signatures of discrete, finite-length fractures, and outlines an approach for elastic, prestack reverse-time imaging of discrete fractures. The results of this study highlight the importance of incorporating fracture-generated P-S converted waves into the imaging method, and presents an alternate imaging condition that can be used in elastic reverse-time imaging when a direct wave is recorded (e.g., for crosswell and VSP acquisition geometries).
Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only a small fraction of ...
The aim of this study was to assess the possibility of digital image analysis of pit-and-fissure discoloration in order to diagnose caries. Digital images showing pit-and-fissure discoloration in 100...Full Text Available
The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available
This paper discusses the clinical application and main objective of testicular imaging. The authors present cases that represent a spectrum of the abnormalities which might be detected by testicular imaging, with special attention given to testicular torsion and the acute diseases which may mimic it clinically. Accuracy of the test is noted.
PurposeAuto-propagation of anatomical region-of-interests (ROIs) from the planning CT to daily CT is an essential step in image-guided adaptive radiotherapy. The...Full Text Available
This paper proposes a novel method for computing linear basis images from tensor-valued image data. As a generalization of the nonnegative matrix factorization, the proposed method aims to approximate...Full Text Available
A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.
Purpose: Small animal micro-CT imaging is being used increasingly in preclinical biomedical research to provide phenotypic descriptions of genomic models. Most of this imaging is coincident...Full Text Available
Epifluorescence images of Ca2+ transients elicited by electrical stimulation of single skeletal muscle fibers were studied with fast imaging techniques that take advantage of the large fluorescence...Full Text Available
Optical coherence microscopy (OCM) is a promising technique or high resolution cellular imaging in human tissues. An OCM system for high-speed en face cellular resolution imaging...Full Text Available
This multiauthored text is aimed particularly toward the resident or registrar training in diagnostic radiology. This is a text book on the entire scope of diagnostic imaging. It includes techniques and imaging modalities of all the systems, head, face and neck. The book covers the entire gamut of diagnostic radiology.
The use of digital wound images would allow remote consultation between patients, physicians, or other caregivers over the Internet. To evaluate the efficacy and validity of digital images for assessment...Full Text Available
Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final...Full Text Available
An image slicing spectrometer (ISS) for microscopy applications is presented. Its principle is based on the redirecting of image zones by specially organized thin mirrors within a custom fabricated...Full Text Available
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...
ObjectiveThis study was conducted to evaluate a computer-imaging program called HAAIR (Help with Adjustment to Alopecia by Image Recovery) that was developed to provide...Full Text Available
Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available
Abstract The aim was to utilize data from a study of occupational indoor environments to analyze symptoms and physiological signs in relation to the home environment. A medical investigation was performed at the workplace among university staff (n = 173) from four university buildings in Bergen, in March 2004. Tear film break up time (BUT) was measured by two methods. Nasal patency was measured by acoustic rhinometry. Nasal lavage fluid analysis (NAL) included eosinophilic cationic protein (ECP); myeloperoxidase (MPO), lysozyme and albumin. Atopy was assessed by total serum IgE and specific IgE (Phadiatop). Totally 21%, 21%, 18%, 11%, and 27% had weekly ocular, nasal, facial dermal symptoms, headache and tiredness, respectively, 15% had a damp dwelling, and 20% had a cat or dog. Multiple l...
Various control procedures have been suggested for reducing foodborne infectious diseases. Receiving considerable attention is irradiation. This report estimates the medical and wage (or productivity) benefits associated with prevention of five human diseases transmitted by beef, pork, and chicken. (These diseases can also be transmitted by other vectors, such as eggs, milk, and pets. But these sources are not included in the analysis.) All of these foodborne infectious diseases - salmonellosis, campylobacteriosis, trichinosis, tapeworm, and toxoplasmosis - could be significantly reduced by irradiating meat and poultry. The Food and Drug Administration (FDA) has just approved irradiation of pork to prevent trichinosis (50FR 29658-59) and is considering approval of irradiation of chicken to kill Salmonella. 22 references.
Nonfunctioning pancreatic endocrine tumors (PETs) are rare and generally asymptomatic. A 68-year-old woman who had refused treatment for a pancreatic mass, revealed by ultrasonography to be 55 mm in diameter, was referred to us again 29 months later with jaundice. Investigations showed an 82-mm tumor in the head of pancreas, exposed from the papilla of Vater to the duodenal lumen. After biliary decompression and drainage, we performed pancreatoduodenectomy with resection of the portal vein and superior mesenteric vein, followed by reconstruction using a cylindrically customized autologous graft harvested from the right ovarian vein. The tumor was resected curatively. Microscopically, it consisted of trabecular and ribbon-like arrangement of neoplastic cells. Immunohistochemical staining wa...
Abstract 1,3 Propanediol (PDO), is now taking the transition from a traditional specialty chemical to a commodity chemical . The market for PDO is growing rapidly as the technology develops. With the advancing PDO production technology, polytrimethylene terephthalate (PTT) as a new type of polyester has been applied in carpet and textile fibers, monofilaments, films, and nonwoven fabrics, and in the engineering thermoplastics area, because PTT has unique properties compared to other polymers such as polyethylene terephthalate (PET) and polybutylene terephthalate (PBT). Responding to the environmental and sustainability factors, one or two step fermentation technology for PDO production has attracted people's attention. A novel flexible process for PDO production by using aerobic fermentati...
Post-mortem magnetic resonance (MR) imaging is of increasing interest not only as an alternative to autopsy but as a research tool to aid the interpretation and diagnosis of in utero MR images. The information from the post-mortem MR has allowed the development of imaging sequences applicable to in utero imaging and neonatal imaging. It has established brain development during gestation and has provided data on this to which in utero MR can be compared. The detail available from the post-mortem images is such that brain development can be studied in a non-invasive manner, a permanent record on the normal and abnormal areas is available and a greater understanding of developmental abnormalities is possible.
The central nervous system is involved in 10-20% of cases in Lyme disease. The neurological symptoms, time course of the disease and imaging findings are multifaceted. We report two patients with cervical radiculitis. Magnetic resonance imaging revealed strong enhancement of the cervical nerve roots on contrast-enhanced T1-weighted images. These imaging patterns of borrelia-associated radiculitis have not been reported before. Knowledge of these imaging features may help to diagnose neuroborreliosis, which presents with non-specific symptoms. (orig.)
Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)
Aug 25, 2004 ... The Tropical Rainfall Measuring Mission or TRMM satellite provided this image of Typhoon Aere over the western Philippine Sea as it was ...
Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available
Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available
Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy electron beam therapy. (author)
A method of increasing information content for content-based image retrieval (CBIR) systems includes the steps of providing a CBIR database, the database having an index for a plurality of stored digital images using a plurality of feature vectors, the feature vectors corresponding to distinct descriptive characteristics of the images. A visual similarity parameter value is calculated based on a degree of visual similarity between features vectors of an incoming image being considered for entry into the database and feature vectors associated with a most similar of the stored images. Based on said visual similarity parameter value it is determined whether to store or how long to store the feature vectors associated with the incoming image in the database.
An image-analysis system, based on commercially available data visualization software (IDL [1]), allows convenient interaction with image data while still providing calculated beam parameters at a rate of up to 2 Hz. Image data are transferred from the IOC to the workstation via EPICS [2] channel access. A custom EPICS record was created in order to overcome the channel access limit of 16k bytes per array. The user can conveniently calibrate optical transition radiation (OTR) and fluorescent screens, capture background images, acquire and average a series of images, and specify several other filtering and viewing options. The images can be saved in either IDL format or APS-standard format (SDDS [3]), allowing for rapid postprocessing of image data by numerous other software tools.
This paper presents two imaging methods by using cross correlation. The one method images the subsurface by cross-correlation of the observed data and partial derivative seismograms calculated for a guessed model. The other method images the interface by use of cross-correlation of the virtual sources and the back propagated wave fields calculated from the observed data. Experimental tests show that both methods image subsurface interfaces well even if the guessed model is different from the true one. These imaging methods are reverse time migration that we perform cross-correlation as an imaging condition and have an advantage, as compared to conventional waveform inversion method, that images subsurface structure without iterative perturbation of the assumed model. (author). 18 refs., 15 figs.
Over the past decade, dramatic increases in computational power and improvement in image analysis algorithms have allowed the development of powerful computer-assisted analytical approaches...Full Text Available
Computed Tomography (CT) and, more recently, ultrasound (US), have proved excellent tools for quantifying adipose tissue distribution. Body fat distribution is an important factor in the treatment of obesity and its complications. In this work it is investigated the correlation between CT and US measurements in pediatric obesity. Forty obese children and adolescents aged 4.1-14.8 years were submitted to CT and US. Intra-abdominal, subcutaneous and total body fat were calculated (in cm{sup 2}), with the CT image analysis software. The rectus muscle-spine and rectus muscle-aorta distances, as indicative of visceral fat thickness, were measured on US images with(out) compression. The distance between skin fat and fat-rectus muscle interfaces was measured as subcutaneous fat thickness. US-CT findings have been compared with other morphometric variables-i.e., patient's (ideal) body weight and skin fold measures. A ...
Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a ...
Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and ...
The authors describe the application of an approximate fuzzy C-means (AFCM) clustering algorithm as a data dimension reduction approach to medical magnetic resonance images (MRI). Image data consisted of one T1-weighted, two T2-weighted, and one T2*-weighted (magnetic susceptibility) image for each cranial study and a matrix of 10 images generated from 10 combinations of TE and TR for each body lymphoma study. All images were obtained with a 1.5 Tesla imaging system (GE Signa). Analyses were performed on over 100 MR image sets with a variety of pathologies. The cluster analysis was operated in an unsupervised mode and computational overhead was minimized by utilizing a table look-up approach without adversely affecting accuracy. Image data were first segmented into 2 coarse clusters, each of which was then subdivided ...
The aims of this study were to quantify the severity and extent of subclinical interstitial lung disease as depicted on HRCT and to study the relationship between the patterns of lung disease quantified by HRCT and the functional parameters and bronchoalveolar lavage findings in patients with rheumatic diseases. The results confirm that HRCT is a sensitive tool in detecting interstitial lung disease in patients with rheumatic diseases with no signs and symptoms of pulmonary involvement. The relationship between the different HRCT patterns and bronchoalveolar lavage cell profiles can identify patients at higher risk of developing irreversible lung fibrosis. A long-term, prospective follow-up study is needed to determine whether these patients will develop over pulmonary disease.
The effect of mean daily air temperature (MDT) on flowering rate (the reciprocal of days to flower) was quantified for 18 species of annual bedding plants. Plants were grown in environmental growth chambers at constant air temperature set points of 5, 7.5, 10, 15, 25, or 30^oC and under an irradiance of 160-180mmolm^-^2s^-^1, with a 16-h photoperiod. Nonlinear mathematical equations were developed to predict the effect of MDT on flowering rate and to estimate the base, optimum, and maximum temperatures (Tmin, Topt, and Tmax), which are the temperatures at which flowering rates are zero (low temperature), maximal, and zero once again (high temperature), respectively. The estimated Tmin varied among species and ranged from 1.1^oC in French marigold (Tagetes patula L.) to 9.9^oC in angelonia ...
One of the challenges facing engineers is developing newer, safer detonators that are equivalent to devices currently in use. There is no clear consensus on an exact method for drawing equivalence of detonators. This paper summarizes our current efforts to develop diagnostics addressing various aspects of detonator design to better quantify and prove equivalency. We consider various optical techniques to quantify the output pressure and output wave shape. The development of a unique interpretation of streak camera breakouts, known as the apparent center of initiation, will be discussed as a metric for detonation wave shape. Specific examples apply these techniques to the comparison of a new laser-driven detonator with an existing exploding bridgewire (EBW) detonator. Successes and short-comings of the techniques will be discussed.
Remote sensing is the most practical method available to managers of fire-prone forests for quantifying and mapping fire impacts. Differenced Normalised Burn Ratio (?NBR) is among the most widely used spectral indices for the mapping of burn severity but is difficult to interpret in terms of fire-related changes in key biophysical attributes and processes. We propose to quantify burn severity as a change in the leaf area index (?LAI) of a stand. LAI is a key biophysical attribute of forests, and is central to understanding their water and carbon cycles. Previous studies have suggested that changes in canopy LAI may be a major contributor to ?NBR and to the composite burn index (CBI) that is frequently used in combination with the NBR to assess burn severity on the ground. We applied remote...
We investigate how, and to what extent, morphological complexity of the language influences text classification using support vector machines (SVM). The Croatian-English parallel corpus provides the basis for direct comparison of two languages of radically different morphological complexity. We quantified, compared, and statistically tested the effects of morphological normalisation on SVM classifier performance based on a series of parallel experiments on both languages, carried over a large scale of different feature subset sizes obtained by different feature selection methods, and applying different levels of morphological normalisation. We also quantified the trade-off between feature space size and performance for different levels of morphological normalisation, and compared the resul...
Properly quantified performance of a solar-thermal cavity receiver must not only account for the energy gains and losses as dictated by the First Law of thermodynamics, but it must also account for the quality of that energy. Energy quality can only be determined from the Second Law. In this paper, an equation developed for the Second-Law efficiency of a cavity receiver is presented as an evolution from the definition of available energy or ''availability'' (occasionally called exergy). The variables required are all either known or readily determined. The importance of considering the Second-Law is emphasized by a comparison of the First- and Second-Law efficiencies around an example of data collected from two receivers that were designed for different purposes, where the attempt was made to demonstrate that a Second-Law approach to quantifying the performance of a solarthermal cavity receiver lends more ...
This case study is an application, to a nuclear power plant, of the methodology for quantifying environmental costs and benefits, contained in the regional energy plan, adopted in April, 1983, by the Northwest Power Planning Council, pursuant to Public Law 96-501.The study is based on plant number 2 of the Washington Public Power Supply System (WNP-2), currently nearing completion on the Hanford Nuclear Reservation in eastern Washington State. This report describes and documents efforts to quantify and estimate monetary values for the following seven areas of environmental effects: radiation/health effects, socioeconomic/infrastructure effects, consumptive use of water, psychological/health effects (fear/stress), waste management, nuclear power plant accidents, and decommissioning costs. 103 references.
Laser-induced phase-separation polymerization of a porous acrylate polymer is used for in-situ fabrication of dialysis membranes inside glass microchannels. A shaped 355 nm laser beam is used to produce a porous polymer membrane with a thickness of about 15 .mu.m, which bonds to the glass microchannel and forms a semi-permeable membrane. Differential permeation through a membrane formed with pentaerythritol triacrylate was observed and quantified by comparing the response of the membrane to fluorescein and fluorescently tagging 200 nm latex microspheres. Differential permeation was observed and quantified by comparing the response to rhodamine 560 and lactalbumin protein in a membrane formed with SPE-methylene bisacrylamide. The porous membranes illustrate the capability for the present technique to integrate sample cleanup into chip-based analysis systems.
MRT is able to demonstrate arteries while MR angiography can quantify blood flow by a non-invasive method. In the present paper blood flow measurements were carried out in four selected cases on the basis of phase mapping. In 3 patients with lesions in the pelvis or thigh, angiography was performed in order to localise the stenosis or occlusion and this was followed by qantitative blood flow measurements. The results showed that angiography may not always provide all necessary information concerning a haemodynamically significant stenosis. The method may also be used for quantifying blood flow in the renal arteries and that it has significant advantages over the colour Doppler method. (orig.).
Abstract A method was developed to quantify the effect of scanner instability on functional MRI data by comparing the instability noise to endogenous noise present when scanning a human. The instability noise was computed from agar phantom data collected with two flip angles, allowing for a separation of the instability from the background noise. This method was used on human data collected at four 3 T scanners, allowing the physiological noise level to be extracted from the data. In a -well-operating- scanner, the instability noise is generally less than 10% of physiological noise in white matter and only about 2% of physiological noise in cortex. This indicates that instability in a well-operating scanner adds very little noise to functional MRI results. This new method allows researcher...
An exposure chamber is described for the quantifiable addition of fine and ultrafine aerosol particulate matter directly to cells and used to demonstrate the in vitro cytotoxicity of fine 1,4-naphthoquinone particles to murine lung epithelial cells. The electrostatic particulate dosage and exposure system (EPDExS) operates on the principle of electrostatic precipitation and is shown to deposit fine and ultrafine aerosol particles directly to cells with 100% efficiency for particle diameters in the range of 40-530nm. This range is not limited by the EPDExS, but rather by the aerosolization method used for this study. Numbers of particles deposited onto the cells are counted with a condensation particle counter, negating any need to calculate or estimate particle exposure. The process of par...
Introduction: Development of agonist positron emission tomography (PET) radioligands for the 5-HT neurotransmitter system is an important target to enable the understanding of human 5-HT function in vivo. ["1"1C]CUMI-101, proposed as the first 5-HT_1_A receptor agonist PET ligand, has been reported to behave as a potent 5-HT_1_A agonist in a cellular system stably expressing human recombinant 5-HT_1_A receptors. In this study, we investigate the agonist properties of CUMI-101 in rat brain tissue. Methods: ["3"5S]-GTP#gamma#S binding studies were used to determine receptor function in HEK (human embryonic kidney) 293 cells transfected with human recombinant 5-HT_1_A receptors and in rat cortex and rat hippocampal tissue, following administration of CUMI-101 and standard 5-HT1A antagonists (5-HT, 5-CT and 8-OH-DPAT). Results: CUMI-101 behaved as an agonist at human recombinant 5-HT_1_A receptors (pEC_5_0 9.2). However, CUMI-101 did not show ...
This thesis is concerned with the crystallisation behaviour of polymers near to a free surface or a buried interface. The properties of polymers are expected to differ significantly near to an interface (either with air or another polymer), due to the contributions of (a) chain configurations induced at the interface, and (b) different mobilities between interfacial regions and the bulk of the sample. For a semi-crystalline polymer, properties such as the degree of crystallinity and the crystallisation kinetics may be enhanced near to a free surface. Grazing incidence x--ray diffraction (GIXD) is used to investigate such effects in poly(ethylene terphthalate) (PET), showing that a lower crystallisation temperature is obtained at the surface, and the crystallisation kinetics are faster at the surface for all temperatures. It is proposed that in thin films of PET, this surface-induced ordering provides nucleation sites for crystallisation in the ...
We investigate theoretically subwavelength imaging by acoustic metamaterial slabs immersed in the liquid matrix. A near-field subwavelength image formed by evanescent waves is achieved by a designed metamaterial slab with negative mass density and positive modulus. A subwavelength real image is achieved by a designed metamaterial slab with simultaneously negative mass density and modulus. These results are expected to shed some lights on designing novel devices of acoustic metamaterials.
X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging
Magnetic resonance imaging can be used in the trauma setting to detect fractures and associated soft tissue injuries of the musculoskeletal system. Magnetic resonance imaging complements plain radiography and CT for evaluating cancellous bone, cartilage and growth-plate injuries, and intra- and extraarticular supporting soft tissue structures. This review outlines typical applications and imaging consideration for injuries of the pelvis and lower extremity. (orig.) With 12 figs., 78 refs.
The computer vision approach to image analysis is discussed from two aspects. First, this approach is constrasted to the pattern recognition approach. Second, how external knowledge and information and models from other fields of science and engineering can be used for image and scene analysis is discussed. In particular, the connections between computer vision and computer graphics are pointed out.
The reconstruction of coronal and Sagittal Image of Brain C. T. is helpful to diagnosis of Brain. Three Dimensional Reconstruction software package allows to display three dimensional Image clerived from a series of Horizontal, Sagittal and Coronal Brain C. T. images. It useful in determine approach of operation, to define portals of deep radiation therapy.
Image representations have gained wide acceptance in displaying data collected during optical, ultrasonic, radiographic, and thermographic inspections. Applying imaging techniques to eddy current testing is explored in this article. The authors show that flaw interpretation and characterization are made considerably simpler when images are used to visualize the impedance changes in eddy current probes.
This report considers the use of a submillimeter wavelength space-based imaging radar. The main application envisioned is midcourse decoy discrimination for strategic defense, for which it would have the capability of producing a series of images, in real time, at strategic ranges, with less than meter scale resolution and with modest power requirements. Undoubtedly, there are other applications. The requirements for a SAR and ISAR imaging radar at submillimeter wavelength are determined, and the prospect for the development of RF sources to power the radar is examined.
The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)
Constrained least-squares techniques have been used to produce a well known class of image restoration algorithms. These techniques typically involve minimizing a linear operator on a vector representation of an image, subject to a constraint. For cases where an equality constraint is appropriate the method of Lagrange multipliers can be used to produce a restored image. In this work a fractal textural model, fractional Brownian motion, is used to represent images of interest. Using a variance fractal dimension estimator a non-linear operator, that represents the squared difference between the fractal dimension of the restored image and on a priori value is minimized, subject to the constraint that the norm of the residual between the restored image and available measurement equal the norm of the additive noise.
Digital libraries need more than just a retrieval based on keywords, which can be inefficient for some applications. Thus, a document retrieval based on content of the digitized image version of the document can be a more appropriated approach. This paper discusses the retrieval of document images by means of identifying a variety of elements present in the document's image body. We propose a new strategy to identify and combine features extracted from a document image. We also consider the task of constructing an optimized feature set to improve the retrieval performance and to validate our experiments on an assorted database. Experimental results show that the proposed segmentation together with a wisely feature combination increase the overall retrieval performance. Moreover the retrieved images demonstrate the generality and effectiveness of our approach for an efficient ...
The brain imaging properties of /sup 99m/Tc glucoheptonate, /sup 99m/Tc pertechnetate, and /sup 99m/Tc DPTA are compared. Results demonstrate that optimum images are obtained at 90, 180, and 180 min., for /sup 99m/Tc GH, /sup 99m/Tc DTPA, and /sup 99m/Tc pertechnetate, respectively. The former two images are not affected by prior bone imaging with /sup 99m/Tc pyrophosphate, while /sup 99m/Tc pertechnetate images are adversely affected. /sup 99m/Tc glucoheptonate appears to be the superior agent for brain imaging, followed by /sup 99m/Tc DTPA and /sup 99m/Tc pertechnetate.
A subsurface imaging system is utilized to test the ability of the spectral polarization difference imaging technique for deep subsurface imaging in tissues. The illumination of the system is derived from compact class III lasers in the red and NIR spectral region and, alternatively, from a white light source and selection of the appropriate illumination wavelength using band-pass optical filters. The experimental results demonstrate detection and imaging of a high-scattering object located up to 1.5 cm underneath the surface of a host chicken tissue.
Gallium imaging is increasingly being used for the early detection of complications in patients with AIDS. A 26-year-old homosexual man who was HIV antibody positive underwent gallium imaging for investigation of possible Pneumocystis carinii pneumonia. Widespread cutaneous focal uptake was seen, which was subsequently shown to be due to mycobacterium avium-intracellulare (MAI) septicemia. This case demonstrates the importance of whole body imaging rather than imaging target areas only, the utility of gallium imaging in aiding the early detection of clinically unsuspected disease, and shows a new pattern of gallium uptake in disseminated MAI infection.
Thallium-201 myocardial imaging was performed in 80 children with coronary arterial lesions due to Kawasaki disease in order to assess the value of serial and exercise myocardial imagings. In eight of these children, abnormalities of the image were noted. Twenty children had serial thallium studies with an interval of three to 18 months, and five of these showed changes in the image including appearance of a new perfusion defect in one patient and improvement of perfusion defects in four. These changes of the myocardial image were correlated well with coronary angiographic findings obtained within a few days of the isotope studies. It was noted that the changes of the myocardial image were more frequently observed at relatively recent period recovered from Kawasaki disease. Exercise myocardial imaging using a bicycle ergometer was performed ...
This paper reports on a Level 1 PRA performed on the Omega West Reactor at Los Alamos National Laboratory. A Master Logic Diagram was used to identify possible initiating events. A chi-square distribution was used to quantify initiating event frequencies given that no initiating events have occurred in 30 years of OWR operation. The PRA results are presented as both probability density function and cumulative distribution function curves.
This paper describes a research and development project to quantify the effects of cleaning the coal feed on the yield patterns and processing rates for the Liquid Solvent Extraction (LSE) direct coal liquefaction process and to obtain information on the effect of the co-refining of coal-derived and petroleum distillates to premium transport fuels. 6 refs., 25 figs., 40 tabs.
We have measured the oxygen positions in LaNiO{sub 3} films to elucidate the coupling between epitaxial strain and oxygen octahedral rotations. The oxygen positions are determined by comparing the measured and calculated intensities of half-order Bragg peaks, arising from the octahedral rotations. Combining ab initio density-functional calculations with these experimental results, we show how strain systematically modifies both bond angles and lengths in this functional perovskite oxide.
Wax appearance temperature (WAT) of three petroleum waxes in different solvent systems under varying thermal conditions has been determined. It is observed that this temperature mainly is a function of the concentration of the wax and the solubility parameter ([delta]) of the solvent taken. This dependence of WAT has been quantified in terms of these variables in the form of mathematical equation and nomographs. (orig.)
Plantago ovata Forsk - an economically important medicinal plant - was analyzed for trace elements and chlorophyll in a study of the effects of gamma radiation on physiological responses of the seedlings. Proton-induced X-ray emission (PIXE) technique was used to quantify trace elements in unirradiated and gamma-irradiated plants at the seedling stage. The experiments revealed radiation-induced changes in the trace element and chlorophyll concentrations.
This research has two main goals; (1) to quantify mechanisms for radon entry into homes of different types and to determine the fraction of indoor radon attributable to each source and (2) to model and calculate the dose (and therefore alpha particle fluence) to cells in the human and animal tracheobronchial tree that is pertinent to induction of bronchogenic carcinoma from inhaled radon daughters.
The alkylation products formed by in vitro treatment of DNA with tritium-labeled 1,3-bis(2-chloroethyl)-1-nitrosourea (3H-BCNU) were identified and quantified. Twelve adducts were resolved...Full Text Available
Due to the intensity and vast number of subjects, this Bremen experts' discussion, too, could discuss only part of the problem of the possibilitiy to quantify the radiation hazard. One preliminary result is that there is no scientific proof of the harmlessness of radiation exposure during normal operation of a nuclear power plant, either within the plant or in its vicinity. Other results are that some important questions can not be answered yet, and that there are important hints on the dangers even of low radiation doses. (GL).
Veterinarians and farmers employing multivalent killed vaccines in lactating dairy cows have reported transient losses in milk production. Few studies have quantified this loss. In this report, effects...Full Text Available
DescriptionAs part of a wider effort to develop new approaches to evaluating and quantifying the benefits of chemicals regulation, this project will review the effectiveness of existing information provision tools (such as classification and labelling for hazardous properties) in terms of affecting user behaviour. As some EC legislation relating to regulation of chemicals has been in place for some time, an assumption is made that the information provided by it is leading to an improvement in the way chem [continued...
We analyze large diffusion-limited aggregates and uncover a {ital discrete} scaling invariance in their inner structure, which can be quantified by the introduction of a set of {ital complex} fractal dimensions. We provide a theoretical framework and prediction of their values based on renormalization group theory and a previous wavelet analysis. {copyright} {ital 1996 The American Physical Society.}
Subtractive imaging in confocal fluorescence light microscopy is based on the subtraction of a suitably weighted widefield image from a confocal image. An approximation to a widefield image can be obtained by detection with an opened confocal pinhole. The subtraction of images enhances the resolution in-plane as well as along the optic axis. Due to the linearity of the approach, the effect of subtractive imaging in Fourier-space corresponds to a reduction of low spatial frequency contributions leading to a relative enhancement of the high frequencies. Along the direction of the optic axis this also results in an improved sectioning. Image processing can achieve a similar effect. However, a 3D volume dataset must be acquired and processed, yielding a result essentially identical to subtractive imaging but superior in ...
X-ray imaging using asymmetric Bragg reflection in the hard x-ray regime opens the way to improve the spatial resolution limit below 1 #mu#m by magnifying the image before detection, simultaneously providing a strong phase contrast. A theoretical formalism of the imaging process is established. Based on this algorithm, numerical simulations are performed and demonstrate that both Fresnel propagation and Bragg diffraction contribute to contrast formation. The achievable resolution of this technique is investigated theoretically; the results obtained can be used to improve future experimental setups. Furthermore, the minimum detectable phase gradient is estimated, for comparison with other phase sensitive imaging techniques. Results from biological objects demonstrate that the technique is viable for imaging both in two and three dimensions. Refraction contrast ...
Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two ...
In our evaluation we utilized the Asahi Mark-J NMR-CT system, with a resistive vertical quadrupolar electromagnet (0.1 Tesla) and a proton resonance frequency of 4.5 MHz. Our main imaging methods are the inversion-recovery or IR, saturation-recovery, or SR, and calculated T/sub 1/. Difference, or D images, constructed by subtracting the data of the IR signal from that of the SR signal, have also been obtained in some cases. The system allows averaging of raw data. Hybrid images were constructed from two or more images to obtain clear definition of areas of interest. By using the hybrid image, several tissues of different relaxation times can be shown in the same image. Application in our study of the newly developed hybrid image indicates its importance in the detection and diagnosis of lesion, especially the detection of the differentiation ...
Quantitative digital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitative image data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial dynamic range, signal-to-noise ratio and ...
Objective: An evaluation of the application of DR in thoracic spine and a comparative study of the DR with the conventional radiography. Methods: DR images and the conventional radiogram of 89 cases respectively were evaluated by 3 vice-consultant doctors and 2 chief technicians. Statistics was processed with 2 categories: (1) images were classified into grade A, B, C and condemned according to the image quality; and (2) thoracic spine are divided into upper, middle and lower portions, in which the rate of successful imaging were compared respectively. Results: The image quality of DR: 74. 1% images in grade A, 20.2% in grade B, 5.7% in grade C, and no image condemned. Conventional radiogram: 45% images in grade A, 41.6% in grade B, 11.2% in grade C, and 2.2% images condemned. The successful ...
Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point source results in a phase contrast too narrow for detection with CR. In addition to phase ...
We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.
Twenty patients with lesions in the trachea or bronchus underwent energy subtraction Fuji computed radiography (FCR). Images obtained were compared with those from conventional FCR (plain FCR). ''Very clear'' images (in which the contour of the trachea and bronchus could be clearly defined) were obtained in 12/22 (55 %) by energy subtraction FCR and in 3/22 (14 %) by plain FCR; ''clear'' images (in which the contour could be defined) in 9/22 (41 %) by energy subtraction FCR and in 18/22 (82 %) by plain FCR; and ''unclear'' images (in which the contour could not be defined) in 1/22 (5 %) by both methods. Energy subtraction FCR, as well as plain FCR, yielded high image quality for the trachea. Energy subtraction FCR was superior to plain films when tumors existed within the trachea. (Namekawa, K.).
Background Computed tomography (CT) and magnetic resonance (MR) imaging can help diagnose benign adrenal adenomas, but prior studies rely on nonoperative follow-up as proof of a lesion?s benign nature. We examined adrenalectomy tissues to determine if imaging characteristics correlate with histopathologic findings. Methods We retrieved data for 196 consecutive adrenalectomies in 192 patients from 2000 to 2008. Imaging results were considered to signify benign adrenal adenoma if one or more of the following was present: Hounsfield units 60% or relative contrast washout of >40%, or MR with chemical-shift imaging demonstrating loss of signal intensity on out-of-phase images. Results The sensitivity and specif...
Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor
An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).
A multiprocessor architecture inspired by the Disney multiplane camera is proposed. For many applications, this approach produces a natural mapping of processors to objects in a scene. Such a mapping promotes parallelism and reduces the hidden-surface work with minimal interprocessor communication and low-overhead cost. Existing graphics architectures store the final picture as a monolithic entity. The architecture here stores each object's image separately. It assembles the final composite picture from component images only when the video display needs to be refreshed. This organization simplifies the work required to animate moving objects that occlude other objects. In addition, the architecture has multiple processors that generate the component images in parallel. This further shortens the time needed to create a composite picture. In addition to generating images for animation, the ...
A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.
Magnetization transfer contrast (MTC) on fast spin echo (FSE) images was evaluated in normal brain tissue as well as in brain tumors to better understand contrast of FSE images. On multislice FSE images, attenuation of the signal intensity of brain tissue due to MTC is observed. The rate of MTC (MTR) is obtained by comparing with additional single slice images. The effect of signal attenuation is greater on images with smaller interslice gap, larger number of slices, and longer echo train length. MTR of brain tumors is less than that of normal brain tissue. Among them, meningiomas have relatively high MTR, and cavernous malformation has relatively low MTR. Determination of MTC can be easily specified by obtaining multislice and single slice FSE images, and it may help differentiate brain tumors. (author).
This paper introduces a parallel measurement approach for fast infrared-based human temperature screening suitable for use in a large public area. Our key idea is based on the combination of simple image processing algorithms, infrared technology, and human flow management. With this multidisciplinary concept, we arrange as many people as possible in a two-dimensional space in front of a thermal imaging camera and then highlight all human facial areas through simple image filtering, image morphological, and particle analysis processes. In this way, an individual's face in live thermal image can be located and the maximum facial skin temperature can be monitored and displayed. Our experiment shows a measured 1ms processing time in highlighting all human face areas. With a thermal imaging ca...
An iterative phase retrieval algorithm was previously investigated for in-line x-ray phase imaging. Through detailed theoretical analysis and computer simulations, we now discuss the limitations, robustness, and efficiency of the algorithm. The iterative algorithm was proved robust against imaging noise but sensitive to the variations of several system parameters. It is also efficient in terms of calculation time. It was shown that the algorithm can be applied to phase retrieval based on one phase-contrast image and one attenuation image, or two phase-contrast images; in both cases, the two images can be obtained either by one detector in two exposures, or by two detectors in only one exposure as in the dual-detector scheme.
X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more ...
X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more precision of ...
Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best ...
Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical ...
The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose ...
The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose ...
Summary Solid state nuclear track detectors are used to determine the concentration of a particles in the environment. The standard method for assessing exposed detectors involves 2D image analysis. However 3D imaging has the potential to provide additional information relating to angle as well as to differentiate clustered hit sequences and possibly energy of a particles but this could be time consuming. Here we describe a new method for rapid high-resolution 3D imaging of solid state nuclear track detectors. A `LEXT' OLS3100 confocal laser scanning microscope (Olympus Corporation, Tokyo, Japan) was used in confocal mode to successfully obtain 3D image data on four CR-39 plastic detectors. Three-dimensional visualization and image analysis enabled characterization of track features. This ...
Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and ...
Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and ...
Water repellency en the microstructure super-hydrophobic cured surface is important for research and industrial purposes. This microstructure film can be cured on polyethylene terephthalate PET surface by electron beam (EB) at different irradiation doses 10-100 kGy. The microstructure formulation composed from hydrophobic acrylate oligomer (EB 244) and monomer (SR 440). The irradiation induced cross linking of the prepared microstructure was proved by FTIR spectroscopy and the adhesion force by abrasion test. Some factors affecting the adhesion force of the prepared microstructure film such as oligomer/monomer composition ratio and the thickness of the microstructure cured film were studied. The contact angles (8) were measured on cured surfaces before and after adding the super hydrophobic nanoparticles (Zonyl 9361). The super-hydrophobic cured surface showed the self-cleaning property. The volume of water droplet affected both the observed contact angle and its ...
Geological clay formations are investigated for use as final underground deposit for heat producing nuclear waste. Special kinds of clay (e.g. bentonite) can also be used for the construction of geotechnical barriers. For the long time safety prognosis of the nuclear waste repositories the development of geochemical transport models is indispensable. The transport of aqueous solutions in clay is a complex process. The three-layer-minerals bentonite and illite swell by the adsorption of water, if the volume is restricted a high swelling pressure develops. The excellent barrier effect of natural clay formations and geotechnical clay barriers is based on the high swelling pressure and the high adsorption capacity for radionuclides and other pollutants. The two-layer-mineral kaolinite has no swelling capacity. In contrast to sandy layers a special geochemical transport potential exists in clay besides the well known matrix potential which influences essentially the transport process. ...
The ink jet printing technology is a relatively novel technique in development of organic electronic devices. The technique consists of working out depositions of organic layers by a piezo-based ink jet printer. In this work polymer conducting films deposited by ink jet printing technique on different plastic substrates has been demonstrated. The poly(3,4-ethylenedioxythiofene)/poly(4-styrenesulfonate) [PEDOT/PSS] and glycerol-modified PEDOT/PSS [G-PEDOT/PSS] were used like conducting inks to be applied on polyester and polyethylene terephthalate (PET) substrates. By means of the change of substrate associated to the deposition number or type of polymer ink used for printing of the conducting films, the sheet resistance can be modified. Such a behavior suggests that plastic substrate fulfills an important role for the changing of sheet resistance of the PEDOT/PSS and G-PEDOT/PSS films made by ink jet printing technique. Films obtained from this technique on ...
An on-line cell disruption system for at-line monitoring of the intracellular concentration of recombinant human superoxide dismutase (rhSOD) in a genetically modified Escherichia coli strain, HMS174(DE3) (pET11a/rhSOD), in bioreactor cultivations is described. The sampled bacteria were disrupted on-line by rapid mixing with a nonionic detergent. The recombinant protein content of the lysed bacterial sample was quantitated by a subsequent surface plasmon resonance biosensor with a specific monoclonal antibody. Extraction efficiency of the monitoring system was optimized with respect to the flow rate ratio of the cell suspension and the detergent at relevant cell densities with the aim to attain rapid monitoring. Monitoring was demonstrated for a shake flask culture and a glucose-limited fed-batch cultivation. The results are compared with a traditional enzyme-linked immunosorbent assay method showing a correlation coefficient of R2 = 0.97. Extraction efficiency of ...
The preS2 antigens of hepatitis B virus (HBV), which causes a serious health problem in the world, have been implicated in hepatocyte cell binding and viral penetration. Therefore, the importance of antibody production against preS2 antigen for early diagnosis of HBV has been well established. In this study, the recombinant HBV preS2 single chain variable fragment (scFv) antibody was successfully expressed in E. coli with the novel cold shock vector (pCold) under the cspA promoter, and its expression level was compared with the pET vector under the T7 promoter. Additionally, a host with an oxidizing cytoplasm, E. coli trxB/gor double mutant, was used to improve the soluble expression. The anti-HBV preS2 scFv using pCold vector was successfully expressed in a soluble and functional form in ...
Volatile compounds produced in flexible food packaging materials (LDPE, EVAc, PET/PE/EVOH/PE) during electron beam irradiation were isolated by purge and trap technique and identified by combined gas chromatography-mass spectrometry (GC/MS), after thermal desorption and concentration. For comparison purposes non-irradiated films were also studied. Film samples were irradiated at low (5 kGy, corresponding to cold pasteurization), intermediate (20 kGy, corresponding to cold sterilization) and high (100 kGy) doses. It was observed that a number of volatile compounds are produced after irradiation in all cases. Furthermore the amounts of all volatile compounds increase with increasing irradiation dose. Both primary (methyl-derivatives etc.) as well as secondary i.e. oxidation products (ketones, aldehydes, alcohols, carboxylic acids etc.) are produced upon irradiation. These products may affect organoleptic properties and thus shelf-life of prepackaged irradiated foods. ...
The effect of atmospheric pressure on tracking resistance of organic insulating materials were investigated in the range of 500 to 1007 hPa. The tracking resistance for Polycarbonate (PC), Modified Polyphenylene Oxide (M-PPO) and Paper Base Phenolic Resin Laminate (PL) increase with the decrease in atmospheric pressure. The scintillating discharges on these samples surface lead to the ignition. The tracking failure on these results from the ignition on the surface. For Polybutylene Terephthalate (PBT) and Polyethylene Terephthalate (PET), the tracking resistance decrease with the decrease in atmospheric pressure. The discharges observed on the these surface are the glow-like. The discharge area spreads on the surface between the electrodes at the lower pressure. The failure on this group results from the carbonization by the discharges on the surface. However, the tracking resistance for Unsaturated Polyester Resins (UP) has no significant dependence on lower ...
The kinetics of "1"8F-fluorodeoxyglucose ("1"8F-FDG) in the monkey brain were monitored, and comparisons were made between the conscious state and when under ketamine and pentobarbital anesthesia. Rhesus monkeys were intravenously injected with "1"8F-FDG and followed by 60 min of PET scanning. In the conscious state, the "1"8F-FDG concentration reached a plateau 5 min after intravenous injection. Under ketamine anesthesia, the "1"8F-FDG concentration gradually increased with time in all monitored regions. At 60 min after injection, the concentration in the striatum was about 3.2 times greater than that in the conscious state, and about 4.5 times greater in the cerebral cortex. Under pentobarbital anesthesia, the "1"8F-FDG concentration in the occipital cortex was slightly lower. These findings demonstrate that "1"8F-FDG concentration in the monkey brain is significantly affected by anesthesia. The results also imply the existence of a short-term regulation ...
The idea to couple the Treatment Planning System (TPS) to the information on the real boron distribution in the patient is the main added value of the new methodology set-up at DIMNP of University of Pisa, in collaboration with the JRC of Petten (NL). The methodology has been implemented in the new TPS, called BDTPS (Boron Distribution Treatment Planning System), which takes into account the actual boron distribution in the patient brain, while the standard TPS assumes a uniform boron distribution, absolutely far from the reality. Nowadays, Positron Emission Tomography (PET) is able to provide this in vivo information. The new TPS, based on the Monte Carlo technique, has been validated comparing the main BNCT parameters (thermal flux, boron dose, etc.) as measured during the irradiation of a special heterogeneous boron phantom (HEBOM), ad hoc designed, as calculated by the BDTPS and by the standard TPS SERA. An evident SERA overestimation of the thermal neutron ...
Non-traumatic osteonecrosis of the femoral head (ONF) is considered to be a disease that occurs primarily due to ischemia of the femoral head, while its etiology and pathology are not fully understood. It is therefore necessary to identify the characteristics of the hemodynamics of the femoral head. In this study, the hemodynamics in the ilium and proximal regions of the femur, including the femoral head, was investigated using positron emission tomography (PET). The subjects of this study consisted of 8 hip joints of four healthy male adults and 3 hip joints on the contralateral side of a femoral neck fracture, avulsion fracture of the greater trochanter and coxarthrosis (1 case each, all females) for a total of 11 hip joints of 7 subjects. The ages of the subjects ranged from 25 to 87 years (average age: 54 years). Blood flow was measured by means of the H_2"1"5O dynamic study method and blood volume was measured by means of the "1"5O-labeled carbon monoxide ...
Power system analysis shows the output from the solar arrays varies as a function .... Each array corresponds to a raw image browse product, which is generated by .... low outgassing, ability to withstand long-term exposure to the space ...
Purpose: The authors have developed a novel technique using an electronic portal imaging device (EPID) to verify the geometrical accuracy of delivery of dose-rate-regulated tracking (DRRT)....Full Text Available
The purpose of this study was to investigate the feasibility of a simple deformable phantom as a QA tool for testing and validation of deformable image registration algorithms. A diagnostic thoracic imaging phantom with a deformable foam insert was used in this study. Small plastic markers were distributed through the foam to create a lattice with a measurable deformation as the ground truth data for all comparisons. The foam was compressed in the superior-inferior direction using a one-dimensional drive stage pushing a flat 'diaphragm' to create deformations similar to those from inhale and exhale states. Images were acquired at different compressions of the foam and the location of every marker was manually identified on each image volume to establish a known deformation field with a known accuracy. The markers were removed digitally from corresponding images prior to ...
Advances in laboratory animal imaging have provided new resources for noninvasive biomedical research. Among these technologies is microcomputed tomography (microCT) which is widely used to obtain high...Full Text Available
Many simulation studies in biomedicine are based on a similar sequence of processing steps, starting from images and running through geometric model generation, assignment of tissue properties, numerical...Full Text Available
To treat or prevent some of the 795,000 annual strokes in the U.S., self-expanding endo-vascular stents deployed under fluoroscopic image guidance are often used. Neuro-interventionalists need...Full Text Available
A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is ...
A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is ...
The simple device for scanning image is described. It has much in common with usual TV camera, with an electron beam replaced by an optical one. After the general description of the device, we present a simple experimental illustration.
Papers are presented in the areas of: Medical Technologies; Non-Destructive Evaluation; Applications of Signal/Image Processing; Laser Guide Star and Adaptive Optics; Computational Electromagnetic, Acoustics and Optics; Micro-Impulse Radar Processing; Optical Applications; TANGO Space Shuttle.
This paper presents a new deformable model using both population and patient-specific statistics to segment the prostate from CT images. There are two novelties in the proposed method. First,...Full Text Available
This review presents a summary of existing knowledge regarding the impact of testicular cancer along four broad domains, including romantic and sexual relationships, body image, and fertility....Full Text Available
Motivated by the observation that a retinal fundus image may contain some unique geometric structures within its vascular trees which can be utilized for feature matching, in this paper, we proposed...Full Text Available
ObjectivesWe have developed an image-guided surgery system based on invisible near-infrared (NIR) fluorescent light. Presently, the only clinically-available NIR...Full Text Available
Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a...Full Text Available
Voxel-based prescriptions of deliberately non-uniform dose distributions based on molecular imaging, so-called dose painting or theragnostic radiation therapy, require specification of a transformation...Full Text Available
An examination of the noise of polycrystalline silicon thin film transistors, in the context of flat panel x-ray imager development, is reported. The study was conducted in the spirit of exploring...Full Text Available
To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe ...
Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available
Although ultrasound arrays were exploited in photoacoustic imaging to improve imaging speed, ultrasound-array-based optical-resolution photoacoustic microscopy (OR-PAM) has never been achieved...Full Text Available
Cancer immunotherapies can be guided by cellular imaging techniques, which can identify the presence or absence of immune-cell accumulation in the tumor tissue in-vivo and in real time. This...Full Text Available
OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available
BackgroundMany three-dimensional (3D) images are routinely collected in biomedical research and a number of digital atlases with associated anatomical and other information have...Full Text Available
This volume contains the proceedings of a symposium entitled In Vivo Imaging of Neurotransmitter Function in Brain, Heart, and Tumors'' held August 24--25, 1990 in Montreal Canada. The six individual papers contained herein are separately abstracted and indexed for the database.
BACKGROUND: Although the importance of lymphatic function is well recognized, the lack of real-time imaging modalities limits our understanding of its role in many diseases. In a phase...Full Text Available
Background and Objectives:Sound enamel manifests peak transparency in the near-IR (NIR) at 1310-nm, therefore the near-IR is ideally suited for high contrast imaging...Full Text Available
Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly different. Conclusion: The ...
RATIONALE AND OBJECTIVESNon-invasive longitudinal imaging of tumor vasculature could provide new insights into the development of solid tumors, facilitating efficient...Full Text Available
Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).
The performance of the Lung Imaging Fluorescence Endoscope (LIFE) system was compared with conventional bronchoscopy in 158 patients: 68 patients with invasive cancer, 42 patients with abnormal sputum...Full Text Available
A two-channel optical system has been developed to provide spatially resolved simultaneous imaging of singlet molecular oxygen (1O2) phosphorescence and photosensitizer (PS) fluorescence...Full Text Available
The capability to image tissue motion such as blood flow through an endoscope could have many applications in medicine. Spectrally encoded endoscopy (SEE) is a recently introduced technique...Full Text Available
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the ...
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the ...
This paper hopes to share the insights we experienced during designing, building, and running an indexing solution for a large set of radiological reports and images in a production environment for...Full Text Available
Previous ultrasound elasticity imaging experiments supported a generally accepted concept that the hardness of deep venous thrombi increases with thrombus aging. Results also showed that this...Full Text Available
We describe a closed-loop brain-computer interface that re-ranks an image database by iterating between user generated 'interest' scores and computer vision generated visual similarity measures. The interest scores are based on decoding the electroencephalographic (EEG) correlates of target detection, attentional shifts and self-monitoring processes, which result from the user paying attention to target images interspersed in rapid serial visual presentation (RSVP) sequences. The highest scored images are passed to a semi-supervised computer vision system that reorganizes the image database accordingly, using a graph-based representation that captures visual similarity between images. The system can either query the user for more information, by adaptively resampling the database to create additional RSVP sequences, or it can converge to a 'done' state. The done state includes a ...
Due to the widespread clinical use of imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available
Functional imaging has revolutionized the neurosciences. In the pain field it has dramatically altered our understanding of how the brain undergoes significant functional, anatomical and chemical changes...Full Text Available
The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y...Full Text Available
Antisense radiopharmaceuticals could be used to image gene expression in the brain in vivo, should these polar molecules be made transportable through the blood–brain barrier....Full Text Available
A high-speed fiber-based network for the transmission and display of digitized full-motion cardiac images has been developed. Based on Asynchronous Transfer Mode (ATM), the network is scaleable, meaning...Full Text Available
We studied 64 ADHD children patients group (4 {approx} 15 ys, mean age: 8 {+-} 2.6 ys. M/F: 52/12) and 12 normal group (6 {approx} 7 ys, mean age: 9.4 {+-} 3.4 ys, M/F: 8/4) of the brain had been used to analysis of blood flow between normal and ADHD group. For analysis of Children ADHD, we used 12 children's mean brain images and made Template image of SPM99 program. In crease of blood flow (P-value 0.05), the result of normalized images to Template image to offer from SPM99 program, showed significant cluster in inter-Hemispheric and occipital Lobe, in the case of normalized images to children template image, showed inter-hemispheric and parietal lobe.
Software for gel image analysis and base-calling in fluorescence-based sequencing consisting of two primary programs, BaseFinder and GelImager, is described. BaseFinder is a framework for trace processing,...Full Text Available
BackgroundThis in vitro study was conducted to compare the accuracy of two digital image receptors in identifying the location of tip of a fine endodontic file and radiographic apex...Full Text Available
Evaluation of the tolerance limits of X-ray image density accepted by the radiologist shows that for different kinds of examinations, deviations of more than 50% from optimal density lead to images which cannot be used diagnostically. Within this range diagnostic accuracy shows a distinct maximum and diminishes to the limits by 20%. These figures are related to differences in the intensifying factor of screens, sensitivity of films, sensitometric parameters of film processing as well as the doses employed with automatic exposure control devices, measured in clinical conditions. Maximum permissible tolerance limits of the whole imaging system and of its constituents are discussed using the Gaussian law of error addition. (author).
The patch and voxel methods are representative examples of the ways in which multi-slice images may be displayed three-dimensionally by means of computer-graphics. Each of them have advantages and disadvantages and they are mutually complementary. We have developed algorithms for a modified voxel method which incorporates the advantages of the patch methods. We have applied this to the three-dimensional image display of brain tumor with excellent results. The three-dimensional reconstructions used for clinical application in this study were derived from X-ray CT images.
The authors present a guide to the imaging of facial fractures. It is illustrated with conventional radiographs and computed tomograms; the magnetic resonance images primarily suggest the potential applications of this technique. This book provides a source of imaging information on facial trauma. A section on pertinent anatomy is followed by a systematic discussion of the common isolated and complex facial fractures. Perspectives are offered on some commonly seen but infrequently described relationships, such as the tripod-LeFort II association. Consideration is also given to related soft-tissue injuries. The book includes a brief chapter on the type and utility of supplementary imaging studies in the evaluation of those intracranial injuries that may occur concurrently.
Disaster impact modeling and analysis uses huge volumes of image data that are produced immediately following a natural or an anthropogenic disaster event. Rapid damage assessment is the key to time critical decision support in disaster management to better utilize available response resources and accelerate recovery and relief efforts. But exploiting huge volumes of high resolution image data for identifying damaged areas with robust consistency in near real time is a challenging task. In this paper, we present an automated image analysis technique to identify areas of structural damage from high resolution optical satellite data using features based on image content.
There is strong interest in lithium imaging, particularly because of its significance in battery materials. However, light atoms only scatter electrons weakly and atomic resolution direct imaging of lithium has proven difficult. This paper explores theoretically the conditions under which lithium columns can be expected to be directly visible using annular bright field scanning transmission electron microscopy. A detailed discussion is given of the controllable parameters and the conditions most favourable for lithium imaging.
A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. The authors established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging
Cross-sectional imaging has revolutionised the radiological diagnosis of pleural collections. Not only can the precise location and volume of a pleural effusion be established, but also features specific for the aetiology of the effusion can be demonstrated. Increasingly, radiologists are called upon to perform image-guided biopsies, aspirations and small bore chest drain placement, all of which have been shown to be safe and efficacious. Pneumothoraces occurring due to acute trauma and in an intensive care setting can also benefit from radiological input, both in terms of diagnosis and image-guided treatment. (orig.)
Multitemporal TM images are used to collect information about the extension and variation of water influx subsidence in coal district in order to provide a reference for the harnessing and utilization of water influx subsidence. The multitemporal TM images are used as a blended data group for the analysis of the principal components to reflect the expanding water influx subsidence in the past years. Because of the differences in the environment and imaging condition, 'unitary' order is used to enhance the 'coherence' and 'comparability' of the original TM images. 5 refs., 4 figs., 2 tabs.
/sup 99m/Tc biliary imaging was performed on a 34-year-old woman who was being investigated for suspected cholelithiasis. A left-sided liver was detected. On subsequent radionuclide imaging, partial visceral situs inversus and asplenia were demonstrated. Extensive roentgenographic investigation, ECG, echocardiogram, and laparotomy confirmed the radionuclide findings. Asplenia syndrome may exist without cardiovascular abnormalities and thus be undiscovered. Radionuclide imaging is important in the diagnosis of this syndrome.
We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes.
The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)
Peripheral primitive neuroectodermal tumors (peripheral PNETs) are rare in the abdomen. We report the imaging findings of four peripheral PNETs arising in the abdomen. Three were ill-demarcated tumors and one was a well-demarcated tumor, with extensive local invasion and lymph node metastasis in two cases, respectively. The tumors are of inhomogeneous attenuation and heterogeneous enhancement after intravenous administration of contrast materials. Although their imaging manifestations cannot distinguish them from other sarcomas, recognition of these imaging features may be helpful in suggesting the possibility of peripheral PNETs in some cases.
A carbon nanotube (CNT) tip, which assembled on the sharp end of a Si tip by dielectrophoresis, was structurally modified using focused ion beam (FIB). We described the imaging characterization of the FIB-modified CNT tip in noncontact AFM mode in terms of wear, deep trench accessibility, and imaging resolution. Compared to a conventional Si tip, the FIB-modified CNT tip was superior, especially for prolonged scanning over 10 h. We conclude that modified CNT tips have the potential to obtain high-quality images of nanoscale structures.
... is the sensor that converts incoming photons into a ... with CCD foundries to acquire such a sensor. ... 2007, Journal of Spacecraft and Rockets, 44, 910 ...
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
ARIES Baker-Nunn Schmidt telescope project is converting a Baker-Nunn satellite tracking camera for Astronomical research. Original Baker-Nunn camera produces an extremely large (5X30 degree) curved focal plane at the prime focus for photographic imaging. We present here the re-designing of the camera produces a wide (4 X 4 degree) flat field of view for CCD imaging observations, which have many scientific potentials in Astronomy. Imaging performance of the CCD camera is also estimated.
This book constitutes the thoroughly refereed post proceedings of the international workshop Computer Vision Approaches to Medical Image Analysis, CVAMIA 2006, held in Graz, Austria in May 2006 as a satellite event of the 9th European Conference on Computer Vision, EECV 2006. The 10 revised full papers and 11 revised poster papers presented together with 1 invited talk were carefully reviewed and selected from 38 submissions. The papers are organized in topical sections on clinical applications, image registration, image segmentation and analysis, and the poster session. (orig.)
Eighty-seven subtraction images of FCR were compared with subtraction images of conventional angiography. Although FCR images with reduced exposure dose (25 % of regular dose) and with diluted contrast material (150 mgI/ml, 50 % of usual concentration) were slightly inferior to the images of conventional angiography, most clinically important vessels were adequately visualized. As FCR has wider dynamic range and higher contrast resolution than conventional angiography, FCR may take over conventional angiography. (author).
The Digital Raster Graphic (DRG) is a raster image of a scanned USGS topographic map including the collar information, georeferenced to the UTM grid....
We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes. (orig.).
We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes.
... order probabilistic modelling, multisensor monitoring of ... object recognition, image registration and point ... of the Berkeley Continuous Media Toolkit. ...
In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).
In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).
A series of real-time, neutron radiography, experiments are ongoing at the Texas A and M Nuclear Science Center Reactor (NSCR). These tests determine the resolving capabilities for radiographic imaging of two phase water and air flow regimes through small diameter flow channels. Though both film and video radiographic imaging is available, the real-time video imaging was selected to capture the dynamic flow patterns with results that continue to improve. (author)
Parathyroid imaging based on the principle of differential uptakes of Tc-99m and T1-201 in the anterior neck to localize parathyroid (PT) disease has been reported with widely varying results. To evaluate the usefulness of this method, we have performed PT imaging on 47 patients prior to exploratory surgery for PT disease. Using pinhole collimation and digital acquisition, a 50k count image of the thyroid was obtained 20 minutes after injection of 1mCi99m Tc-pertechnetate. Then a lmCi dose of Tl-201 chloride was injected and a series of images acquired for 30 minutes at 30 sec/image. Raw data was spatially filtered and normalized by summing sufficient T1-201 images to equal the Tc-99m image scale of maximum cts/pixel. Image subtraction (Tl-Tc) gave the final PT image. Of 10 pts who had previous neck ...
Results of the evaluation of the scattered radiation effect on the image of defects in examined products are given. The formula is suggested which characterizes the image of defects on a scintillation screen as well as accumulation factors are calculated by the Monte-Carlo method. Values of fluctuations of absorbed energy in the screen used for the evaluation of sensitivity are experimentally obtained. The effect of high-energy bremsstrahlung on the defect detection is analyzed.
For comparison of radiation exposure and risk in different diagnostic procedures for adults and children dose measurements and calculations of organs with special risk were carried out. Parameters of image formation influencing image quality as well as of exposure concerning infants and children are recorded and discussed as to radiation exposure and protection. Conclusions are drawn with respect to systems of image formation and to standards of examination and quality assurance.
The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.
In this article, the authors recall the factors apt to influence image quality in NMR Imaging and present the european works that have been developed in MRIQA to set 5 quality assurance tests: EUROSPIN 1 to 5.
Sponsored by the Defense Advanced Research Projects Agency the Image Understanding Workshop is a forum for the presentation of new research in vision, image analysis, and geometric modeling. Leading scientists present overviews of projects underway at major universities and corporate research sites, as well as results of individual work. The 1987 volume contains 94 articles and technical reports in two volumes.
The characteristics of real-time neutron radiography are described briefly in this paper, and the acquirement of neutron flux, the selection of convertor and the structure of the twilight imaging system and the image-sampling and image-processing system in SPRR-300 reactor are also analyzed detailedly. The experimental result of real-time neutron radiograph is too analyzed in this paper
This manuscript reviews some of the more controversial dose-related issues in cardiac CT imaging. Discussion covers the relative merits of cardiac CT versus MR, advantages and concerns regarding gated versus nongated cardiac CT and advantages and concerns regarding the use of breast shields in girls undergoing cardiac CT imaging.
The image processing system for the dynamic neutron radiography has been developed. It is based on the hardware subset, composed by the method of the pipe-line and use of algorithm of local statistics. The processing speed per one pixel is shorter than 100 n sec and video-rate processing can be executed on it. Some image processes for improving the quality of the real-time neutron image, noise reduction and contrast stretching would be attempted by the use of this system. (author).
An analyzer-based X-ray phase-contrast imaging (ABI) setup has been mounted at the Brazilian Synchrotron Light Laboratory (LNLS) for multiple imaging radiography (MIR) purposes. The algorithm employed for treating the MIR data collected at LNLS is described, and its reliability in extracting the distinct types of contrast that can be obtained with MIR is demonstrated by analyzing a test sample (thin polyamide wire). As a practical application, the possibility of studying ophthalmic tissues, corneal sequestra in this case, via MIR is investigated.
A thermal neutron imaging facility for computed tomography and real-time neutron radiography is being developed at the University of Texas at Austin. The TRIGA reactor is a graphite-reflected Mark It pool-type research reactor. The neutron imaging facility will use beam port, which is at one end of a through part. Monte Carlo calculations were used to design the neutron collimator for this facility.
The "1"3"1I-labelled monoclonal antibodies 791T/36 and 79IT/36 Fab fragments have been evaluated in the imaging of patients with colorectal cancer, with benign colorectal tumours, and with malignant tumours of other parts of the gastrointestinal tract. The results of clinical imaging have been carefully correlated with clinical findings and direct measurement of the preferential uptake of antibody by the tumours. (UK).
A pulsed field gradient spin echo sequence has been incorporated in a nuclear magnetic resonance (NMR) imaging experiment to provide an image contrast dependent on local molecular self-diffusion. The...Full Text Available
We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.).
The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.).
The authors report an extension of the source imaging method for analyzing three-dimensional sources from three-dimensional correlations. The technique consists of expanding the correlation data and the underlying source function in spherical harmonics and inverting the resulting system of one-dimensional integral equations. With this strategy, they can image the source function quickly, even with the extremely large data sets common in three-dimensional analyses.
We have investigated the detection performance of GaAs detectors made with different thickness and contact geometries. A comparison is made between these detection capabilities and the imaging requirements for the following medical applications: digital mammography, digital chest radiography and nuclear medicine. Experimental results and preliminary images are presented and discussed. (author)
In this study, an apparatus suitable to photoacoustic (PA) imaging to measure blood-analysis and urinalysis is fabricated and its measurement scheme has been established for the first time. The PA imaging of urinalysis test strip, blood sugar test strip, and cholesterol test strip is performed. A calibration curve of PA measurement is obtained for a urine test strip. The detectivity is better than that obtained by an eye-measurement.
Our goal is to determine an optimized image-guided setup by comparing setup errors determined by two-dimensional (2D) and three-dimensional (3D) image guidance for head and neck cancer (HNC)...Full Text Available
We describe a model of damage in rf cavities and show how this damage can limit cavity operation. We first present a review of mechanisms that may or may not affect the ultimate fields that can be obtained in rf cavities, assuming that mechanical stress explains the triggers of rf breakdown events. We present a method of quantifying the surface damage caused by breakdown events in terms of the spectrum of field enhancement factors, Beta, for asperities on the surface. We then model an equilibrium that can develop between damage and conditioning effects, and show how this equilibrium can determine cavity performance and show experimental evidence for this mechanism. We define three functions that quantify damage, and explain how the parameters that determine this performance can be factored out and measured. We then show how this model can quantitatively explain the dependence of cavity performance on material, frequency, pulse length, gas, ...
There is currently considerable interest in identifying and quantifying the effects of welding procedure parameters and steel composition factors on the risk of cracking in pipeline girth welds that may be experienced during winter construction. Although low ambient temperatures, that may be experienced during winter construction, are generally assumed to increase the risk of cracking there has been little work to quantify the effects and to suggest how welding procedures should be modified for winter conditions. The present work was undertaken to calculate the effects of changes in welding parameters on the thermal cycle and the diffusion of hydrogen for a typical pipeline girth weld. A simple analytical method and the finite element method (FEM) were used. Both methods gave similar results but the simple method was very sensitive to the value of heat transfer coefficient. The results showed that the relation between the hydrogen diffusion ...
To investigate the potential causes of changes to bird communities in exurban areas, we examined the relationship between bird and macro invertebrate communities in exurbanized forest. We randomly located sampling points across a gradient of exurbanization. We used point counts to quantify bird communities and sweep netting, soil cores, pitfalls, and frass collectors to quantify macro invertebrates. Bird communities had higher richness and abundance in exurban areas compared to undeveloped forests, and lost some species of conservation concern but gained others. The macro invertebrate community was slightly more abundant in exurban areas, with a slight shift in taxonomic composition. The abundance of macro invertebrates in soil cores (but not pitfalls) predicted the abundance of ground-foraging birds. The abundance of macro invertebrates in sweep nets was not associated with the abundance of aerial insectivore birds. Exurbanization therefore ...
Properly quantified performance of a solar-thermal cavity receiver must not only account for the energy gains and losses as dictated by the First Law of thermodynamics, but it must also account for the quality of that energy. However, energy quality can only be determined from the Second Law. In this paper an equation for the Second-Law efficiency of a cavity receiver is derived from the definition of available energy or availability (occassionally called exergy), which is a thermodynamic property that measures the maximum amount of work obtainable when a system is allowed to come into unrestrained equilibrium with the surrounding environment. The fundamental concepts of the entropy and availability of radiation are explored from which a convenient relationship among the reflected cone half angle, the insolation, and the concentrator geometric characteristics is developed as part of the derivation of the Second-Law efficiency. A comparison is made between First- ...
Local cardiac glucose utilization (LCarGU) was quantified in the rat heart according to the Sokoloff model and local cardiac blood flow (LCarBF) according to the /sup 14/C-iodoantipyrine method. For quantitative autoradiography calibration curves for heart slices were performed. They differed from the brain calibration curves by 8%. The lumped constant was 0.377 in isolated working hearts. LCarGU and LCarBF could then be quantified in awake rats. At different locations mean LCarGU of different hearts varied from 85 to 200 ..mu..moles/100g/min and mean LCarBF from 390 to 831 ml/100g/min. The ratio subendocardial/subepicardial glucose utilization or blood flow was not systematically different from 1. The results indicate that glucose can be an important fuel in the heart of the awake rat, although its contribution to overall metabolism varies from animal to animal.
JAERI has been performing transient core thermal-hydraulic test program. In the program, authors performed BWR/ABWR DBE simulation tests with a test facility, which can simulate BWR/ABWR transients. The test facility has a 4 x 4 bundle core simulator with 15-rod heaters and one non-heated rod. Through the tests, authors quantified the thermal safety margin for core cooling. In order to quantify the thermal safety margin, authors collected experimental data on post-CHF. The data are essential for the evaluation of clad temperature transient when core heat-up occurs during DBEs. In comparison with previous post-CHF tests, present experiments were performed in much wider experimental condition, covering high clad temperature, low to high pressure and low to high mass flux. Further, data at wider elevation (lower to higher elevation of core) were obtained in the present experiments, which make possible to discuss the effect of axial position on ...
An exposure chamber is described for the quantifiable addition of fine and ultrafine aerosol particulate matter directly to cells and used to demonstrate the in vitro cytotoxicity of fine 1,4-naphthoquinone particles to murine lung epithelial cells. The electrostatic particulate dosage and exposure system (EPDExS) operates on the principle of electrostatic precipitation and is shown to deposit fine and ultrafine aerosol particles directly to cells with 100% efficiency for particle diameters in the range of 40-530nm. This range is not limited by the EPDExS, but rather by the aerosolization method used for this study. Numbers of particles deposited onto the cells are counted with a condensation particle counter, negating any need to calculate or estimate particle exposure. The process of particle introduction, assessed using Trypan blue dye exclusion, had no effect on cell viability. In combination with a differential mobility classifier, the EPDExS can deliver ...
In rare instances, carbon monoxide (CO) levels in houses can reach dangerously high concentrations, causing adverse health effects ranging from mild headaches to, under extreme conditions, death. Hundreds of fatal accidental carbon monoxide poisonings occur each year primarily due to the indoor operation of motor vehicles, the indoor use of charcoal for cooking, the operation of malfunctioning vented and unvented combustion appliances, and the misuse combustion appliances. Because there is a lack of simple, inexpensive, and accurate field sampling instrumentation, it is difficult for gas utilities and researchers to conduct field research studies designed to quantify the concentrations of CO in residences. Determining the concentration of CO in residences is the first step towards identifying the high risk appliances and high-CO environments which pose health risks. Thus, there exists an urgent need to develop and field-validate a ...
A real-time two-dimensional void fraction distribution measurement of gas-liquid two-phase flow was carried out by real-time neutron radiography and real-time image processing. The JRR-3M real-time thermal neutron radiography system and a Musashi dynamic image processing system were used. Image processing methods to calculate two-dimensional and cross-sectional void fraction distributions were proposed. The void fraction distribution was calculated by non-linear processing of the neutron radiography image and displayed by pseudo-color in real-time. A simple gas-liquid two-phase flow induced by injecting gas through needles at the bottom of water pool in a rectangular vessel was tested. (orig.).
MR images of steady and pulsatile disturbed flow, obtained with use of flow-compensated spin-echo (SE) and cine pulse sequences, revealed excellent flow visualization in three dimensions. Phantoms, built from molds of actual blood vessels, reproduced laminar, disturbed, or turbulent flow. Video recording (VR), performed under conditions equivalent to those of the MR experiments, showed separation zones identical to those seen on SE images. Pulsatile flow studies showed complex patterns of vortical flow on cine images and VR. Varying pulse sequence details changed contrast but not flow patterns. The validation of MR observations by VR has implications for clinical cine imaging and low abnormal signals observed on MR angiograms.
VSP reverse-time migration is a well adaptable wave equation migration method. Its control equation not only describes all-direction propagation of seismic wave but also removes interbed multiples. Clearbout's image principle is generalized to determine image conditions, real VSP data are used to determine boundary condition, and two way reflection-free wave equation is solved by making reverse-time extrapolation. In each step of extrapolation, the migration value at relevant image point is obtained by using the image condition. The complete migration of a seismic section is achieved when reverse-time extrapolation reaches the minimum image time. In this paper it is proved theoretically and practically that this method is applicable to any velocity variation and makes the migrated section have both good resolution and high S/N ratio. Besides, this method results in high ...
The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase imaging with respect ...
The auroras on Jupiter and Saturn can be studied with a high sensitivity and resolution by the Hubble Space Telescope (HST) ultraviolet (UV) and far-ultraviolet (FUV) Space Telescope spectrograph (STIS) and Advanced Camera for Surveys (ACS) instruments. We present results of automatic detection and segmentation of Jupiter's auroral emissions as observed by HST ACS instrument with VOronoi Image SEgmentation (VOISE). VOISE is a dynamic algorithm for partitioning the underlying pixel grid of an image into regions according to a prescribed homogeneity criterion. The algorithm consists of an iterative procedure that dynamically constructs a tessellation of the image plane based on a Voronoi Diagram, until the intensity of the underlying image within each region is classified as homogeneous. The computed tessellations allow the extraction of quantitative information about the auroral features such as mean ...
Two peptide ligands conjugated adenine, [9-N-(tritylmercapto acetyl diglycyl aminoethyl) adenine, Tr-MAG_2-Ade] and [9-N-(tritylmercapto acetyl triglycyl aminoethyl) adenine, Tr-MAG3-Ade], are synthesized and labeled with "9"9"mTc by directly labeling method. The stability of "9"9"mTc-MAG_2- adenine and "9"9"mTc-MAG_3-adenine in vitro is measured. The uptake radios of tumor to muscle at 3h post-injection are 5.70 and 4.92, respectively. The biodistribution and scintigraphic imaging studies show that the two complexes have high localization in tumor and high contrasted tumor images can be obtained, which suggest their potential utility as tumor imaging agents. But the high radioactivity of abdomen could prevent the tumor imaging in this area. (author)
In a fluoroscopic imaging system, image quality and patient dose are both affected by the optical system linking the image intensifier with the video camera. The effect on patient exposure of increasing the optical iris aperture size over that required for other procedures performed on the same imaging system was investigated for the air-contrast barium enema examination. Using a large-area transmission ionisation chamber to monitor the Roentgen-area-product of entrance exposure, a decrease in fluoroscopic radiation of greater than 50% was clinically documented for a fluoroscopic system utilising kVp and mA variable automatic brightness control. For this iris change, the video image was of acceptable quality for positioning and monitoring the patient, and no deleterious effect was detected in the conduct of the air-contrast exam. The availability of a variable-sized ...
A photoacoustic (PA) imaging system based on an ultrasonic Fresnel zone plate (FZP) transducer is developed for the purpose of imaging biological tissue. This FZP transducer has a two-zone negative zone plate piezoelectric material pattern, and an optical fibre is integrated with the transducer on the symmetric axis of the zone plates to deliver laser pulses to the sample. The focal characteristic of the FZP transducer is analysed by theoretical prediction and experimental measurement, and the measured results are in good agreement with the predicted results. The limited-field back-projection deconvolution algorithm combined with the coherence-factor weighting technique is used to reconstruct the optical absorption distribution. The experiments were performed with phantoms and the blood vessels of chicken embryo chorioallantoic membrane. The results demonstrate that PA imaging using the FZP transducer has the ability to ...
An algorithm for creating synthetic telescope images of Smoothed Particle Hydrodynamics (SPH) density fields is presented, which utilises the adaptive nature of the SPH formalism in full. The imaging process uses Monte Carlo Radiative Transfer (MCRT) methods to model the scattering and absorption of photon packets in the density field, which then exit the system and are captured on a pixelated image plane, creating a 2D image (or a 3D datacube, if the photons are also binned by their wavelength). The algorithm is implemented on the density field directly: no gridding of the field is required, allowing the density field to be described to an identical level of accuracy as the simulations that generated it. Some applications of the method to star and planet formation simulations are presented to illustrate the advantages of this new technique, and suggestions as to how this framework could support a ...
The field of a digital-image processing has experienced dramatic growth and increasingly widespread applicability in recent years. Fortunately, advances in computer technology have kept pace with the rapid growth in volume of image data in these and other applications. Digital image processing has become economical in many fields of research and in industrial and military applications. While each application has requirements unique from the others, all are concerned with faster, cheaper, more accurate, and more extensive computation. The trend is toward real-time and interactive operations, where the user of the system obtains preliminary results within a short enough time that the next decision can be made by the human processor without loss of concentration on the task at hand. An example of this is the obtaining of two-dimensional (2-D) computer-aided tomography (CAT) images. A medical decision might ...
We propose a combined migration velocity analysis and imaging method based on Kirchhoff integral migration and reverse time migration, using the residual curvature analysis and layer stripping strategy to build the velocity model. This method improves the image resolution of Kirchhoff integral migration and reduces the computations of the reverse time migration. It combines the advantages of efficiency and accuracy of the two migration methods. Its application in tunnel seismic prediction shows good results. Numerical experiments show that the imaging results of reverse time migration are better than the imaging results of Kirchhoff integral migration in many aspects of tunnel prediction. Field data show that this method has efficient computations and can establish a reasonable velocity model and a high quality imaging section. Combination with geological information can make an ...
In the autonomous unmanned helicopter landing problem, the position of the unmanned helicopter relative to the landmark is very important. A camera carried on the unmanned helicopter can capture an image of the landmark. In earlier research, it was reported that the camera position could be estimated by features extracted from the landmark image. However, it is necessary that the landmark image should be complete, or with only slight deficiencies, in order for this estimation process to be possible. In this article, we report on an innovative design for an estimation made from a camera position giving an incomplete single image of the landmark. An adaptive neuro-fuzzy inference system (ANFIS) is used to construct the mapping relation between the features of complete and incomplete landmark...
We introduce a multi-layered image cache system that is designed to work with a pool of rendering engines to facilitate an interactive, frameless, asynchronous rendering environment. Our system decouples the rendering from the display of imagery. Therefore, it decouples render frequency and resolution from display frequency and resolution, and allows asynchronous transmission of imagery instead of the compute/send cycle of standard parallel systems. It also allows local, incremental refinement of imagery without requiring all imagery to be re-rendered. Images are placed in fixed position in camera (vs. world) space to eliminate occlusion artifacts. Display quality is improved by increasing the number of images. Interactivity is improved by decreasing the number of images.
Purpose Study the radiolysis of solid-state metoclopramide hydrochloride at various absorbed doses. Elucidate the structure of the degradation products to gain information on the radiolysis mechanisms. Methods Solid-state metoclopramide samples were irradiated at several doses with gamma rays and high-energy electrons to evaluate the influence of the dose rate. High-performance liquid chromatography with a diode array detector was used to measure the chemical potency as a function of the absorbed dose and to quantify the degradation products. The characterization of degradation products was performed by liquid chromatography/atmospheric pressure chemical ionization/tandem mass spectrometry. Results The degradation of solid-state metoclopramide after irradiation was negligible. No qualitati...