WorldWideScience
2

Lung cancer screening program using annual chest radiographs with computed radiography (FCR)  

Energy Technology Data Exchange (ETDEWEB)

In the Wajima lung cancer screening program conducted under the auspices of Kanazawa University Hospital, Fuji Computed Radiography (FCR) was utilized in a new chest radiography trial. The results of the screening program are that the necessity of repeat examinations due to poor image quality are less common and the method enables detection of small pulmonary nodular shadows which are possibly candidates for surgery. Oblique chest X-ray with FCR is remarkably effective for the detection and the identification of small lesions. However, the disadvantage of slow processing and high cost must be fully satisfied if FCR is to become a new imaging modality for mass screening.

1987-08-01

3

Lung cancer screening program using annual chest radiographs with computed radiography (FCR)  

International Nuclear Information System (INIS)

In the Wajima lung cancer screening program conducted under the auspices of Kanazawa University Hospital, Fuji Computed Radiography (FCR) was utilized in a new chest radiography trial. The results of the screening program are that the necessity of repeat examinations due to poor image quality are less common and the method enables detection of small pulmonary nodular shadows which are possibly candidates for surgery. Oblique chest X-ray with FCR is remarkably effective for the detection and the identification of small lesions. However, the disadvantage of slow processing and high cost must be fully satisfied if FCR is to become a new imaging modality for mass screening. (author).

1987-01-01

4

MRT versus CT in the diagnosis of pneumonia. Evaluation of a T_2-weighted utrafast turbo-spin-echo sequence (UTSE)  

International Nuclear Information System (INIS)

Purpose: To evaluate a T_2-weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T_2-weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR_e_f_f/T_E/Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis and representation of the lesions, in 25% MRT was superior. MRT was better for the ...

1999-05-01

5

Assessment of 1183 screen-detected, category 3B, circumscribed masses by cytology and core biopsy with long-term follow up data  

UK PubMed Central (United Kingdom)

Discrete masses are commonly detected during mammographic screening and most such lesions are benign. For lesions without pathognomonically benign imaging features that are still regarded likely to...Full Text Available

2008-04-08

6

Detection of Mitochondrial DNA Mutations in Mammary ...  

Science.gov (United States)

... Loss of Heterozygosity in Normal Breast Epithelial Tissue and Benign Breast Lesions in BRCA1/2 Carriers with Breast Cancer. ...

2004-09-01

7

Color Fluorescence Ratio for Detection of Bronchial Dysplasia and Carcinoma In situ  

UK PubMed Central (United Kingdom)

BackgroundAutofluorescence bronchoscopy is more sensitive than conventional bronchoscopy for detecting early airway mucosal lesions. Decreased specificity can lead...Full Text Available

2009-07-15

8

Surveillance for the detection of early lung cancer in patients with bronchial dysplasia  

UK PubMed Central (United Kingdom)

BackgroundThe natural history of bronchial preinvasive lesions and the risk of developing lung cancer in patients with these lesions are not clear. Previous studies have treated...Full Text Available

2007-01-01

9

Digital direct magnification mammography with storage phosphor screens. Standardized and image result dependent post-processing parameters  

International Nuclear Information System (INIS)

Present day mammography has not been able to make use of the advantages of digital luminescence radiography because of the limited spatial resolution. The recent development of electromagnetic focusing X-ray tube with effective focal spot sizes from 0.04 to 0.12 mm allows radiographic direct magnification with less geometric blur. It is now possible to combine direct magnification mammography with digital luminescence radiography. By combining high quality storage phosphor screens with an HQ-workstation a spatial resolution of 8 lp/mm is possible for 1.7-fold magnification. For 4-fold spot magnification views spatial resolution can be theoretically increased to approx. 20 lp/mm. One important advantage of digital radiography is the possibility of image-postprocessing. This article presents two sets of standard parameters and three sets of image dependent parameters for better imaging of specific lesions, such as microcalcifications. The ...

10

Computed Tomography of the spine in multiple myeloma  

International Nuclear Information System (INIS)

Computed Tomography (CT) of the spine was performed on 17 patients with myeloma in order to assess the role of the technique in recognizing and evaluating the extent of the lesions. Myelomatous lesions followed two patterns at CT: first of all, multiple focal lesions, whose density is either solid, liquid, or fatty; second, an extensive pattern involving the spongiosa of the vertebra, including the posterior arch. CT detected more lesions than conventional radiology; furthermore, the extent of the lesions was much better demonstrated by CT. CT should thus be performed: a) in case of pain and/or neurological findings in negative radiological examinations; b) to evaluate the extent of myelomatous lesions (mainly in the spine); c) in solitary myeloma CT may be performed on different bone segments with clinical symptomatology but normal X-ray ...

1988-01-01

11

Comparative evaluation of Computed Tomography and Magnetic Resonance Imaging (1.5 T) in the detection of brain metastases  

International Nuclear Information System (INIS)

Forty-four patients with small cell carcinoma of the bronchus underwent CT and MR studies of the brain to detect cerebral metastases. All patients were studied with contrast-enhanced CT scans, short (T1-weighted) and long (T2-weighted), spin-echo (SE) and FLASH 90 grades sequences were also obtained. A quantitative comparison of the results was carried out to assess the sensitivity of the different techniques in the detection of brain metastases according to lesion diameter. Metastases were identified in 19/44 patients (43%). All techniques detected the lesions >2 cm; of the metastases <2 cm, 63/124 (51%) were detected only by GdDTPA SE-T1 and FLASH sequences and 11 more (9%) only by Gd-DTPA SE-T1 scans. All the lesions identified oh enhanced CT scans or on T2-weighted images were easily detected by Gd-DTPA scans. ...

1991-01-01

12

High resolution Computed Tomography in the study of temporal bone trauma  

International Nuclear Information System (INIS)

Thirty-five patients with temporal bone fractures were examined; the fractures were sometimes associated with dislocation of the assicular chain caused by road fatalities. Computed Tomography (CT) was performed either because of the presence of clinical symptoms associated with trauma of the temporal bone, because of a hemotympanum discovered during a CT scan of the brain. Thirty-three fractures were detected: 19 longitudinal, 6 transverse, and 8 complex. An incudostapedial dislocation was also detected, together with a displacement of a stapedial prosthesis from the lenticular process of incus, and 3 incus-malleus dislocation associated with fractures. High resolution CT allows the precise definition of the course of the fractures, of the associated dislocation of the ossicular chain, and of facial nerve lesion, thus allowing a more accurate surgical intervention. In the examination of the temporal bone, high resolution CT ...

1988-01-01

13

Role of MRI in the diagnostic evaluation of parotid diseases  

International Nuclear Information System (INIS)

MRI findings in 13 patients with monolateral parotid tumor were compared with US, sialographic and CT findings. MRI did not allow an accurate diagnosis in 2 patients with diffuse chronic parotitis. MRI was superior to CT in 1 case in defining the intraglandular site of the lesion, and in 2 patients in showing the extraglandular involvement. MRI proved to be superior to CT thanks to its contrast resolution and to multiplanar imaging. MRI high contrast resolution made it possible to demonstrate neoplastic lesions of 4 mm in diameter. The lesion has low signal intensity on T1-weighted images and high signal intensity on T2-weighted. Parotid tumors cannot be characterized by signal intensity alone: only morphology allows to discriminate between benign and malignant lesions. To conclude, US is a screening method, while MRI is helpful in detecting multifocal lesions ...

1988-01-01

14

Modern imaging methods for diagnostic evaluation of tumors of the oropharynx and the oral cavity  

International Nuclear Information System (INIS)

Differentiating a benign from a malignant lesion by information such as density data, or signal intensities or echo gradients, is not possible with CT, nor MRI, nor ultrasonography. Only some lesions show characteristic signs. Inflammations cannot be difscriminated from malignant tumors. CTs of small tumors in particular are so poor in contrast that it is much more difficult to detect tumors or discriminate them from other lesions, as compared to MR images or ultrasonographs. CT does not detect surface tumors, but is more sensitive than MRI or US in detecting discrete cortical bone lesions. The same applies to small calcified tumors. MRI however is most sensitive in detecting tumor volumes in the yellow marrow, and is the best modality for evaluation of extraossal extension of tumors. CT yields better results than MRI if ...

15

Comparative evaluation of US, CT and MR imaging in the diagnosis of hepatocellular carcinoma in cirrhotic patients  

International Nuclear Information System (INIS)

The contribution of US, CT and MR imaging was investigated in 25 cirrhotic patients with hepatocellular carcinoma. The following parameters were considered: lesion detection, site and size of the lesion, daughter nodules, location and/or infiltration of intrahepatic vessels, patency of portal vein and collateral vessels, signs of chronic liver disease, steatosis, ascitis, and lymphadenopathy. The results confirm the value of US, which also allowed lesion biopsy in all cases. CT was as accurate as US in detecting the lesion and even superior in demonstranting daughter nodules. MR imaging, with conventional SE and IR sequences, was inferior since it missed 3 lesions due to motion artifacts; more over, a smaller number of daughter nodules was seen than with CT. The authors conclude that, at present, MR imaging cannot replace US and CT; the ...

1991-01-01

16

CT colonography with minimal bowel preparation: evaluation of tagging quality, patient acceptance and diagnostic accuracy in two iodine-based preparation schemes  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to compare a 1-day with a 2-day iodine bowel preparation for CT colonography in a positive faecal occult blood test (FOBT) screening population. One hundred consecutive patients underwent CT colonography and colonoscopy with segmental unblinding. The first 50 patients (group 1) ingested 7*50 ml iodinated contrast starting 2 days before CT colonography. The latter 50 patients (group 2) ingested 4*50 ml iodinated contrast starting 1 day before CT colonography. Per colonic segment measurements of residual stool attenuation and homogeneity were performed, and a subjective evaluation of tagging quality (grade 1-5) was done. Independently, two reviewers performed polyp and carcinoma detection. The tagging density was 638 and 618 HU (p = 0.458) and homogeneity 91 and 86 HU for groups 1 and 2, respectively (p = 0.145). The tagging quality was graded 5 (excellent) in 90% of all segments in group 1 and 91% ...

2010-02-15

17

Uncommon bone tumors of the skull: Ewing's sarcoma and Triton's tumor  

International Nuclear Information System (INIS)

Ewing's sarcoma and Triton's tumor are two uncommon bone tumors of the skull that have nonspecific clinical and imaging features. However, imaging methods are important in the detection of the lesions during the diagnostic investigation in order to evaluate the extent of the bone lesions, involvement of the soft tissues and brain, and to determine the presence of local recurrence and metastases. The confirmatory diagnosis relies on histological studies and immunohistochemistry. The authors report two cases of patients with these tumors and present the radiological findings. (author)

18

Computed radiography (FCR) with a dual side reading system. Comparison with conventional radiography for visualization of nodular lung cancers  

International Nuclear Information System (INIS)

To assess the diagnostic capability Fuji computed radiography (FCR) using a dual side reading system was compared to the conventional radiography using a film-screen system. Twenty-eight patients with lung cancer were examined with a new FCR system (FCR 5501D) and a conventional screen-film system concurrently. FCR utilizes a reading system that detects emissions from dual sides of imaging plate. Chest X-rays were obtained with same exposure factors in both systems. Image qualities of both systems were compared by two radiologists using a five-level score. There were no lesion that FCR images were inferior to film-screen images. The frequency of score +1 or +2 that FCR images were superior to film-screen images was 31% in large nodular shadows, 40% in accompanying shadows with a nodule, 67% of small nodular shadows, and 43% of the lymph node swelling in the hilum of the lung or mediastinum. In large nodular shadows which ...

2003-02-01

19

Early Detection of Bronchial Lesions Using Lung Imaging Fluorescence Endoscope  

UK PubMed Central (United Kingdom)

The performance of the Lung Imaging Fluorescence Endoscope (LIFE) system was compared with conventional bronchoscopy in 158 patients: 68 patients with invasive cancer, 42 patients with abnormal sputum...Full Text Available

1999-01-01

20

Diagnostic Performance of Computed Tomography Colonography in Symptomatic Patients and in Patients with Increased Risk for Colorectal Disease  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate the diagnostic performance (colorectal lesions) of computed tomography (CT) colonography in 111 patients, a majority of whom were at high risk for colorectal neoplasia. Material and Methods: After bowel preparation, CT colonography was performed, immediately followed by conventional colonoscopy. The diagnostic performance of CT colonography was analyzed relative to lesion size, histological diagnosis, and diagnostic certainty. Results: The sensitivity of CT colonography increased with lesion size (P<0.001), and was 91% (21/23) for lesions > or = 10 mm. All 10 carcinomas and 86% (19/22) of adenomas > or = 5 mm were detected. Unconfirmed or false-positive CT findings were generally small and/or reported with low diagnostic certainty. The specificity of CT colonography would be 45% (30/66; 95% CI 34% to 57%) if patients with findings of any ...

2006-11-15

21

Application of 18F-fluorodeoxyglucose positron emission tomography to detection of proximal lesions of obstructive colorectal cancer  

International Nuclear Information System (INIS)

In cases of obstructive colorectal cancer (CRC), preoperative diagnosis of the proximal lesion is often difficult when the primary lesion impedes the passage of the endoscope. The aim of this study was to evaluate the usefulness of fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) in such cases. A total of 52 obstructive CRC patients who underwent preoperative FDG-PET and subsequent surgical resection were retrospectively reviewed. The correlation between characteristics of the proximal lesion and FDG-PET findings was analyzed statistically. There was a significant correlation between the proximal lesion size and the maximum standardized uptake value (P=0.00016). Abnormal FDG accumulation in the proximal colon indicated the existence of proximal cancer or adenoma with a sensitivity of 50% and a specificity of 100%. There was a significant difference in the distribution of tumor size ...

2010-10-01

22

Computed radiography in X-ray examination of stomach. Evaluation by phantom experiments and clinical studies  

Energy Technology Data Exchange (ETDEWEB)

The usefulness and clinical applicability of computed radiography(FCR) in X-ray examination of the stomach were evaluated in comparison with film-screen (FS) radiography by both phantom experiments and clinical studies. Receiver operating characteristic (ROC) curve analysis consisting of 25 normal and 25 artificially created simulated lesions on an orginally created Styrofoam phantom showed no difference in lesion detectability between FCR and FS radiography. Both were also equal in evaluation of the internal structure and margin of the 25 lesions by visual ranking. ROC curve analysis of clinical cases was performed in 30 cases, 20 normal and 10 abnormal, while evaluation by visual ranking was performed on 18 lesions. There was no significant difference between FCR and FS radiography either with ROC curve analysis or visual ranking, although the variations were somewhat greater in ...

1995-08-01

23

Computed radiography in X-ray examination of stomach. Evaluation by phantom experiments and clinical studies  

International Nuclear Information System (INIS)

The usefulness and clinical applicability of computed radiography(FCR) in X-ray examination of the stomach were evaluated in comparison with film-screen (FS) radiography by both phantom experiments and clinical studies. Receiver operating characteristic (ROC) curve analysis consisting of 25 normal and 25 artificially created simulated lesions on an orginally created Styrofoam phantom showed no difference in lesion detectability between FCR and FS radiography. Both were also equal in evaluation of the internal structure and margin of the 25 lesions by visual ranking. ROC curve analysis of clinical cases was performed in 30 cases, 20 normal and 10 abnormal, while evaluation by visual ranking was performed on 18 lesions. There was no significant difference between FCR and FS radiography either with ROC curve analysis or visual ranking, although the variations were somewhat greater in ...

1995-01-01

24

Quality assurance and classification performance testing of 125I - brachytherapy seeds  

International Nuclear Information System (INIS)

125I-seeds are extensively used in ocular and interstitial brachytherapy for the treatment of various malignant lesions. Quality assurance and classification performance testing of indigenously produced 125I-seeds were carried out for ensuring their safety in different brachytherapy applications. The sources were found to qualify Class -43211 specifications, in accordance with AERB SS-3 and ISO-2919. (author)

2008-11-26

25

Preoperative MR-guided localization of suspicious breast lesions; MR-gesteuerte praeoperative Drahtmarkierung unklarer Mammalaesionen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Small suspicious breast lesions that are only visible at MR imaging were preoperatively marked with a hook wire under MR-guidance to allow the removal of the lesion with tissue-sparing surgery. Method: In all patients the suspicious lesions were marked preoperatively under MR guidance with a hook wire using a commercially available stereotactic device. Interventions were performed with MR guidance on a 1.0 T and on a 1.5 T system. Results: In 19 patients 22 lesions were localized. One lesion was missed and removed in a second procedure. The mean duration for localization was 66{+-}20 min (range 38-119 min). In two patients two lesions were localized. The mean deviation of the wire tip to the lesion was 2,0{+-}2,6 mm. In this series, 6 of 22 lesions were malignant. The mean diameter of the ...

2000-09-01

26

Computed tomography (CT) in renal trauma  

International Nuclear Information System (INIS)

CT scans were performed on 25 patients suspected of sustaining ranal trauma. The utility of CT in both detecting renal damage and appraising the gravity of injuries was assessed. Nowadays, in fact, nephrectomy or reserved for lesions devastanting the kidney parenchyma or rupturing the renal pedicle; so it is very important to identyfy both the purposes of a better planned therapeutic approach. CT does both, being more accurate than urography in the detection of renal fractures, intra or extraparenchymal hematomas and contrast media extravasation. Urography very often shows aspecific lesion patterns and sometimes it is also falsely negative. In the present series CT was more reliable than angiography itself, particulary in the diagnosis of extra-renal hematic collections, contrast media extravasation and injuries to the other abdominal organs. Although CT may arouse the suspicion of and sometimes ...

1987-01-01

27

Imaging of gastrinomas by nuclear medicine methods  

International Nuclear Information System (INIS)

Somatostatin receptor scintigraphy (SRS) is a valuable method for the detection of somatostatin receptor-positive lesions. Most gastrinomas (over-)express the somatostatin receptor subtype 2 which can be targeted by In-111 labeled Octreotide. Different studies show a high sensitivity of SRS for the localization and staging of gastrinomas. SRS seems to be superior to other non-invasive imaging modalities and has been proven to significantly contribute to patient management. However, the sensitivity depends on the size and exact localization of the tumors. Smaller lesions and lesions located in the duodenum show a significantly lower sensitivity. In any case, SRS belongs to the routine imaging procedure for gastrinomas for localization and staging and can also be used for evaluation of the tumor progression. (author)

28

MRT versus CT in the diagnosis of pneumonia. Evaluation of a T{sub 2}-weighted utrafast turbo-spin-echo sequence (UTSE); MRT versus CT in der Diagnostik von Pneumonien. Evaluation einer T{sub 2}-gewichteten ultraschnellen Turbo-Spin-Echo-Sequenz (UTSE)  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate a T{sub 2}-weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T{sub 2}-weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR{sub eff}/T{sub E}/Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis and representation of the lesions, in 25% MRT was superior. MRT was ...

1999-05-01

29

Phantom simulation device for scintillation cameras  

Energy Technology Data Exchange (ETDEWEB)

A phantom simulation imaging quality control device is described that effectively simulates one centimeter lesions, using steel ball bearings as gamma ray attenuators. The bearings are mounted in a synthetic resinous sheet in an orthogonal pattern. The phantom can provide uniformity, resolution, linearity, distortion and field size checks, all with a single exposure.

1981-08-25

30

The influence of scattered radiation on recording systems and quality-assurance test parameters  

International Nuclear Information System (INIS)

Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).

1988-02-23

31

The influence of scattered radiation on recording systems and quality-assurance test parameters  

International Nuclear Information System (INIS)

Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).

32

Clinical trial of NMR-CT, (4). Clinical evaluation of hybrid image  

Energy Technology Data Exchange (ETDEWEB)

In our evaluation we utilized the Asahi Mark-J NMR-CT system, with a resistive vertical quadrupolar electromagnet (0.1 Tesla) and a proton resonance frequency of 4.5 MHz. Our main imaging methods are the inversion-recovery or IR, saturation-recovery, or SR, and calculated T/sub 1/. Difference, or D images, constructed by subtracting the data of the IR signal from that of the SR signal, have also been obtained in some cases. The system allows averaging of raw data. Hybrid images were constructed from two or more images to obtain clear definition of areas of interest. By using the hybrid image, several tissues of different relaxation times can be shown in the same image. Application in our study of the newly developed hybrid image indicates its importance in the detection and diagnosis of lesion, especially the detection of the differentiation of an edematous lesion from a tumor, and also abnormal fluid ...

1985-01-01

33

Imaging techniques for the injured ankle joint and tarsal bones  

International Nuclear Information System (INIS)

In the case of injuries of the ankle joint, an imaging technique is expected to reveal the state of the bones, ligaments, and articular cartilage. Irrespective of novel imaging techniques, a plain radiography will be made in order to obtain a first picture of the injury. Examples are given, showing that further orientation along the Lauge-Hansen classification scheme of this type of injury helps to completely ascertain the damage to the Articulatio talocruralis. Further examinations applying specific methods such as arthrography will detect possible, isolated syndesmosis ruptures; lesions of the ligaments can also be directly detected by CT or MRT. The articular cartilage and its lesions can be visualized by a combination of CT and arthrography, but are better shown by the completely non-invasive MRT. This latter method also gives insight into pathological processes with the bone. It allows to ...

34

An immunochemical approach to the study of DNA damage and repair  

Energy Technology Data Exchange (ETDEWEB)

The overall objective of this project is to produce antibodies to unique modified DNA bases and develop immunochemical assays to quantitate these lesions in damaged DNA. During this past year we have developed an antibody and chemical test to quantitate a basic sites in DNA and produced antibodies to the 8-oxopurines. This report discusses the detection of a basic sites in DNA and the preparation of antibodies to 8-hydroxyadenine and 8-hydroxyguanine.

1990-11-14

35

AIDS and lung infection by Mycobacterium xenopi. Role of Computed Tomography  

International Nuclear Information System (INIS)

Mycobacterium xenopi is one of the most common agents responsible for nontubercolar mycobacterial pulmonary disease on AIDS patients. These lesions have been studied with conventional radiography while CT has been used in patients with a specific mycobacterioses or non-AIDS pulmonary conditions from Mycobacterium xenopi. 12 AIDS patients were examined. They had pulmonary lesions from Mycobacterium xenopi, patients age ranged 30 to 46 years. All patients had CD4 blood levels lower than 250 cells/mL and Mycobacterium xenopi in the sputum. All patients underwent a standard chest radiograph and a CT examination. CT images were evaluated by three radiologists independently and the definitive diagnosis was made in the presence of a fourth radiologist. Chest CT showed parenchymal consolidation in 66% of cases, associated with bilateral basal bands in 16% of cases. Consolidation was unilateral in 41% of cases and most frequently involved the right ...

2000-06-01

36

Detection of Microcalcification in Mammograms Using Wavelet Transform and Fuzzy Shell Clustering  

CERN Document Server

Microcalcifications in mammogram have been mainly targeted as a reliable earliest sign of breast cancer and their early detection is vital to improve its prognosis. Since their size is very small and may be easily overlooked by the examining radiologist, computer-based detection output can assist the radiologist to improve the diagnostic accuracy. In this paper, we have proposed an algorithm for detecting microcalcification in mammogram. The proposed microcalcification detection algorithm involves mammogram quality enhancement using multirresolution analysis based on the dyadic wavelet transform and microcalcification detection by fuzzy shell clustering. It may be possible to detect nodular components such as microcalcification accurately by introducing shape information. The effectiveness of the proposed algorithm for microcalcification ...

2010-01-01

37

Computerized Tomography versus unenhanced and enhanced fast MRI sequences in the study of liver metastases: Qualitative and quantitative analyses  

International Nuclear Information System (INIS)

The authors compared unenhanced and contrast-enhanced fast MRI and Computerized Tomography in the detection of liver metastases. Eleven patients with single or multiple hepatic lesions (42 in all) were submitted to V and magnetic resonance studies; T1- and T2- weighted TSE, T2-weighted TSE with fat suppression, unenhanced breath-hold TFE and early or delayed enhanced breath-hold TFE images were acquired with a 1.5 T superconductive magnet (Philips NT). The quantitative analysis of all magnetic resonance images was performed for contrast/noise ratio (CNR) and number of detected lesions; magnetic resonance and Computerized Tomography images were also compared qualitatively for lesion conspicuity, anatomical structure identification and artifacts. The results were compared with Student's test. Early enhanced breath-hold TFE was statistically superior to T1-weighted TSE (p = .0009), ...

1997-01-01

38

Improving the Quality of Life  

Wastenet

...and supply ensuring better food quality for the consumer developing safer and more flexible food production processes and technologies raw materials for food production; production and processing systems; by-products and wastes from fisheries and agro-industry; new food sources; packaging systems; quality monitoring; traceability Food contamination detecting and eliminating infectious and toxic agents throughout the food chain establishing the hazards and origins of food contaminants producing food more safely rapid ...

39

The MonoPrep Pap test for the detection of cervical cancer and its precursors. Part I: results of a multicenter clinical trial.  

Science.gov (United States)

The MonoPrep Pap Test (MPPT; MonoGen, Lincolnshire, IL) is a novel, liquid-based specimen collection and processing technology for cytologic and molecular testing. Its usefulness in the detection of cervical cancer and its precursors was evaluated in a multicenter, masked, adjudicated, split-sample study of 10,739 samples. After preparation of a conventional smear, the residuum on the collection device was rinsed into a collection vial from which an MPPT slide was prepared. Accuracy was assessed by masked reference interpretation by an independent pathologist. Slides prepared by MPPT, compared with smears, yielded statistically significant increases in relative sensitivity for atypical squamous cells of undetermined significance and worse, atypical squamous cells, cannot exclude high-grade squamous intraepithelial lesion/atypical glandular cells and worse, and low-grade squamous intraepithelial lesion and worse. There was ...

2008-02-01

40

MRI with SPIR sequences of optic nerve lesions; Utilita' delle sequenze 'Selective Partial Inversion Recover' (SPIR) nelle mallattie del nervo ottico  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the yield of SPIR sequences with fat suppression in the diagnosis of optic nerve lesions. T1 and T2 weighted fat suppressed SPIR imaging of the optic nerve improves anatomical definition, lesion detection and characterization in optic nerve conditions. [Italian] L'articolo analizza i vantaggi ricavabili dall'utilizzazione delle sequenze SPIR nella documentazione del decorso del nervo ottico e delle sue alterazioni nei pazienti con sospetto clinico e strumentale di malattia retrobulbare. L'utilizzo delle sequenze SPIR consente ottimale visualizzazione del nervo ottico e delle sue eventuali alterazioni senza gli artefatti che limitavano la qualita' delle immagini nelle prime sequenze RM con soppressione del segnale del grasso.

1999-04-01

41

Diagnosis of breast cancer with MR imaging using the magnetization transfer contrast and a newly-developed breast surface coil for the supine position  

Energy Technology Data Exchange (ETDEWEB)

We developed a new breast surface coil for the supine position. The subjects consisted of 9 patients with breast cancer varying from 46 to 60 years of age (average: 52). The cancer image of the SPGR (CE+) method was compared with that of the FSMTC (MTC-SPGR (CE+)) method and that of the FSMTC (MTC-SPGR with fat-saturation (CE+)) method in the sagittal section after injection of Gd-DTPA (0.1 mmol/kg). Quantitative analyses were performed before and after injection of Gd-DTPA in 6 patients. Three patients were excluded from the quantitative analyses owing to the clear detection of tumors in the fat tissue. Signal intensity measurements were systematically performed in each region of interest (ROI), i.e. the cancer lesion, the surrounding mammary gland. Statistical analyses showed significant differences between the lesions using the FSMTC (MTC-SPGR (CE+)), and the FSMTC (MTC-SPGR with fat-saturation (CE+)) methods and the ...

1998-09-01

42

CT versus MRI in the study of the articular diseases of the knee  

International Nuclear Information System (INIS)

The authors present a comparison between the diagnostic accuracy of Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) in the articular pathologies of the knee. CT and MRI were performed in 30 patients who subsequently underwent surgery. CT and MRI results were compared on three bases: technique, definition of normal anatomy, and diagnostic accuracy. CT allowed a standardization of the technique, while MRI was superior in defining normal anatomy - especially in the study of capsulo-ligamentous structures. In all cases the use of both CT and MRI allowed a correct diagnosis, showing the site, extent and gravity of the lesion. CT proved to be superior to MRI in 4 cases, while MRI corrected CT diagnosis in 11 cases; in 15 patients both techniques had the same diagnostic accuracy. Meniscal tears were better identified by CT, while MRI was superior in the detection of ligamentous lesions and in the characterization of ...

1988-01-01

43

Digital direct magnification mammography with storage phosphor screens. Standardized and image result dependent post-processing parameters; Digitale Vergroesserungsmammographie mit Speicher-Folien-Technik. Standardisierte und befundorientierte Bildverarbeitungsparameter  

Energy Technology Data Exchange (ETDEWEB)

Present day mammography has not been able to make use of the advantages of digital luminescence radiography because of the limited spatial resolution. The recent development of electromagnetic focusing X-ray tube with effective focal spot sizes from 0.04 to 0.12 mm allows radiographic direct magnification with less geometric blur. It is now possible to combine direct magnification mammography with digital luminescence radiography. By combining high quality storage phosphor screens with an HQ-workstation a spatial resolution of 8 lp/mm is possible for 1.7-fold magnification. For 4-fold spot magnification views spatial resolution can be theoretically increased to approx. 20 lp/mm. One important advantage of digital radiography is the possibility of image-postprocessing. This article presents two sets of standard parameters and three sets of image dependent parameters for better imaging of specific lesions, such as microcalcifications. The ...

1997-05-01

44

Enhancement pattern of hilar cholangiocarcinoma: Contrast-enhanced ultrasound versus contrast-enhanced computed tomography  

International Nuclear Information System (INIS)

Objective: To compare the enhancement pattern of hilar cholangiocarcinoma on contrast-enhanced ultrasound (CEUS) with that on contrast-enhanced computed tomography (CECT). Methods: Thirty-two consecutive patients with pathologically proven hilar cholangiocarcinomas were evaluated by both low mechanical index CEUS and CECT. The enhancement feature of the tumor, portal vein infiltration, and lesion conspicuity on them was investigated. Results: In the arterial phase, the numbers of the lesions showing hyperenhancement, isoenhancement, and hypoenhancement, were 14 (43.8%), 14 (43.8%), and 4 (12.6%), on CEUS, and 12 (37.5%), 9 (28.1%), and 11 (34.4%), on CECT (P = 0.162). In portal phase, the numbers of the lesions showing hypoenhancement, isoenhancement, and hyperenhancement were 30 (93.8%), 1 (3.1%), and 1 (3.1%), on CEUS, and 23 (71.9%), 8 (25.0%), and 1 (3.1%), on CECT (P = 0.046). The detection rates ...

2010-08-01

45

Lipiodol-CT in the detection of tumor persistence in hepatocellular carcinoma treated with percutaneous ethanol injection  

Energy Technology Data Exchange (ETDEWEB)

Our purpose was to investigate the usefulness of Lipiodol-CT for detection of residual viable neoplastic tissue in hepatocellular carcinoma (HCC) lesions treated by means of percutaneous ethanol injection (PEI). An emulsion of 5 to 20 ml iodized oil and 50 to 70 mg doxorubicin hydrochloride was intraarterially injected in 18 patients with 25 HCC lesions treated by means of PEI one to 24 months before. At CT performed 3 to 5 weeks after injection, retention of Lipiodol was observed in 9 of 13 tumors that still contained viable neoplastic tissue and in 2 of 12 tumors proven to have undergone complete necrosis after PEI. The sensitivity and specificity of Lipiodol-CT were 69.2% and 83.3%, respectively. Thus, Lipiodol-CT seems to have limited diagnostic value after PEI, probably as a consequence of the alcohol-induced vascular damage, accounting for both false-negative and false-positive results. (orig.).

1994-07-01

46

Detection of abnormalities in febrile AIDS patients with In-111-labeled leukocyte and Ga-67 scintigraphy  

International Nuclear Information System (INIS)

Thirty-six patients with acquired immunodeficiency syndrome (AIDS), who were febrile but without localizing signs, underwent indium-111 leukocyte scintigraphy 24 hours after injection of labeled white blood cells (WBCs) and were restudied 48 hours after injection of gallium-67 citrate. Fifty-six abnormalities were identified as possible sources of the fever; 27 were confirmed with biopsy. Of these 27, 15 were identified only on In-111 WBC scans (including colitis, sinusitis, and focal bacterial pneumonia); six, only on Ga-67 scans (predominantly Pneumocystis carinii pneumonia and lymphadenopathy); and six, on both studies (predominantly pulmonary lesions). In-111 WBC scanning revealed 21 of 27 abnormalities (78%) and gallium scanning, 12 of 27 (44%). If only one scintigraphic study has been performed, particularly with Ga-67, a significant number of lesions would not have been detected. The authors believe radionuclide ...

47

Assessment of arterial tumor vascularity in small hepatocellular carcinoma. Comparison between color Doppler ultrasonography and radiographic imagings with contrast medium: dynamic CT, angiography, and CT hepatic arteriography  

Energy Technology Data Exchange (ETDEWEB)

Hepatocellular carcinoma (HCC) is characterized by tumor vascularization from the hepatic artery. The objective of our work was to compare color Doppler ultrasonography (CDU), including power Doppler ultrasonography (PDU) with radiographic imagings with contrast medium in regard to the detection of the arterial tumor vascularity of small hepatocellular carcinomas (HCC). We examined 42 small HCC lesions 2 cm or less in diameter in 37 patients for arterial tumor vascularity by conventional CDU, PDU, dynamic computed tomography (dCT), digital subtraction angiography (DSA), and CT hepatic arteriography (CTA). Color images were detected in 25 (59.5%) and 28 (66.7%) of the 42 lesions with conventional CDU and PDU, respectively, and tumor vascularity was detected in 26 (61.9%) by dCT, 23 (54.8%) by DSA, and 29 (69.0%) by CTA. Tumor vascularity could be detected in ...

2000-10-01

48

PET/CT-guided interventional procedures: rationale, justification, initial study, and research plan  

International Nuclear Information System (INIS)

Positron-emission tomography (PET) and PET/CT (computed tomography) are becoming increasingly important for diagnosis and treatment of cancer. Clinically relevant changes can sometimes be seen on PET that are not seen on other imaging modalities. However, PET is not suitable for guiding biopsy as the images are not obtained in real-time. Therefore, our research group has begun developing a concept for PET/CT-guided interventional procedures. This paper presents the rationale for this concept, outlines our research plan, and includes an initial study to evaluate the relative sensitivity of CT and PET/CT in detecting suspicious lesions. (orig.)

2007-06-01

49

CERES BDS Quality Summaries - Atmospheric Science Data Center - NASA  

Science.gov (United States)

Nov 18, 2010 ... Roughly speaking, the fidelity interval we quote is a "3 sigma" value. ... surface of the foremost quartz filter which is then chemically altered by ... ( CERES) scanner point accuracy using a coastline detection system", ...

50

Demonstration of the metastatic pulmonary nodules by Fuji Computed Radiography (FCR)  

International Nuclear Information System (INIS)

Twenty one examinations of chest FCR were performed in 15 malignancies with pulmonary metastases. The rate for demonstrating, less than 5, from 5 to 15, and more than 15 mm pulmonary nodules using with FCR was retrospectively evaluated on the basis of the lesions detected with CT. The demonstrating rate for pulmonary nodules less than 5 mm in diameter was only 8 % ; for 5 - 15 mm nodules, about 87 %. However, several 5 - 15 mm nodules were not demonstrated due to overlap of the pulmonary vessels and bony structures. All nodules more than 15 mm were demonstrable. Chest FCR may demonstrate more pulmonary nodules than conventional radiography. However, the further studies should be required for the improvement of detectability of them with FCR. (author).

1987-01-01

52

On-line measurement and inspection technologies of surface properties of steel sheets; Koban hyomen hinshitsu no onrain keisoku oyobi kensa gijutsu  

Energy Technology Data Exchange (ETDEWEB)

In steel production lines such as pickling lines, cold rolling mills and coil processing lines, the needs for on-line continuous measurement of surface quality and property of products and on-line inspection of surface defects have become strong. This is because user requirements for the surface quality of various products have become severer than before and besides, expectations are running high on the side of manufacturers for higher speeds of production lines and higher quality by the adoption of automatic inspection. As for the measurement of surface quality, continuous measurements along the full length of a steel strip are required in order to overcome problems derived from off-line, batch measurements that cannot satisfy user's demands for quality assurance. As for surface defects detection, various kinds of methods have been practically applied ...

1999-12-01

53

3-Methyl-3-deazaadenine, a stable isostere of N3-methyl-adenine, is efficiently bypassed by replication in vivo and by transcription in vitro.  

Science.gov (United States)

The goal of the present work was to determine the impact of N3-methyladenine (3-mA), an important lesion generated by many environmental agents and anticancer drugs, on in vivo DNA replication and in vitro RNA transcription. Due to 3-mA chemical instability, the stable isostere 3-methyl-3-deazaadenine (3-m-c(3)A) was site specifically positioned into an oligodeoxynucleotide. The oligomer was, then incorporated into a vector system that is rapidly converted to ssDNA inside yeast cells and requires DNA replication opposite the lesion for plasmid clonal selection. For control purposes, an adenine or a stable apurinic/apyrimidinic (AP)-lesion was placed at the same site. The presence of each lesion in the oligonucleotide was confirmed by MALDI-TOF analysis. Plasmids were then transfected into yeast cells. While the AP-site dramatically reduced plasmid replication in all strains, the 3-m-c(3)A had a slight ...

2011-06-14

54

Evaluation of computer-aided detection of lesions in mammograms obtained with a digital phase-contrast mammography system  

Energy Technology Data Exchange (ETDEWEB)

A computer-aided detection (CAD) system was evaluated for its ability to detect microcalcifications and masses on images obtained with a digital phase-contrast mammography (PCM) system, a system characterised by the sharp images provided by phase contrast and by the high resolution of 25-{mu}m-pixel mammograms. Fifty abnormal and 50 normal mammograms were collected from about 3,500 mammograms and printed on film for reading on a light box. Seven qualified radiologists participated in an observer study based on receiver operating characteristic (ROC) analysis. The average of the areas under ROC curve (AUC) values for the ROC analysis with and without CAD were 0.927 and 0.897 respectively (P = 0.015). The AUC values improved from 0.840 to 0.888 for microcalcifications (P = 0.034) and from 0.947 to 0.962 for masses (P = 0.025) respectively. The application of CAD to the PCM system is a promising approach for the detection of ...

2009-12-15

55

Particle identification by modified Bragg-curve centroid detection  

Energy Technology Data Exchange (ETDEWEB)

A new article identification method based on the measurement of Bragg-curve centroids using a gas-filled ionization chamber has been improved for detection of low-energy particles around 1 MeV per nucleon by introducing a nonuniform distribution of resistance on the anode electrode. Almost the same quality of Z-resolutions as in the conventional ..delta..E-E method could be obtained up to Z=19.

1987-03-01

56

Giant magnetoresistance sensing technologies for detecting small defects in metallic structures  

Science.gov (United States)

Giant magnetoresistance (GMR) has been used with Eddy current testing to detect small defects not only in thin film structures but also in multilayered metallic structures. This work detected small scratches in the thin film under the surface where these defects were unable to be inspected or monitored by regular testing. In addition, rotational GMR magnetic sensor based Eddy current probes were used for detecting buried corner cracks at the edge of holes in metallic structures. The results of this study proved that giant magnetoresistance is very powerful and effective to sense the magnetic field, which is the result from the perturbation of the Eddy currents caused by a defect. This method can be used for quality control of metallization layers on silicon wafer and to detect cracks in thick structures such as cracks in aging aircraft.

2008-01-01

57

Radiation-induced damage to DNA; Les lesions radio-induites de l'ADN  

Energy Technology Data Exchange (ETDEWEB)

This short survey focuses on the main radiation-induced base lesions that have been identified within cellular DNA. For this purpose, sensitive assays that are aimed at measuring a few modifications per 10{sup 7} normal bases were set-up. In that respect high performance liquid chromatography - tandem mass spectrometry (CLHP-MS/MS) was found to be able to single out the formation of 9 oxidized nucleosides and two modified nucleo-bases out of the 70 oxidative base lesions that have been identified in model systems. As a striking result, it was found that in the DNA of {gamma}-irradiated human monocytes, the formamide-pyrimidine derivative of guanine is produced in a higher yield than the ubiquitous 8-oxo-7,8-dihydro-guanine damage, both arising from the same radical precursor. However, relatively high doses of ionizing radiation (> 20 Gy) have to be applied in order to detect an increase in the level of the damage. ...

2002-03-01

58

Clinical application of dual energy subtraction in direct digital radiography of chest  

International Nuclear Information System (INIS)

Objective: To discuss the clinical application value of dual energy subtraction (DES) in direct digital radiography of chest. Methods: 83 cases of chest digital radiography(DR) using double-energy subtraction (DES) were randomly selected, and three posterior-anterior (PA) chest films (standard image, bone image and soft tissue image) were obtained in each case, which is so called 'bone and soft tissue separated' technology. Results: With the aid of double energy subtraction (DES), the bony chest was subtracted, the sensitivity and specificity of pulmonary calcification were improved, and sensitivity of pulmonary nodes was also improved, enhancing the distinction between pulmonary benign or malignant lesions, enlightening the diagnosis of chest cage lesions, and showing a clear superiority in the detection of pulmonary nodes comparing to common chest films. The double energy subtraction (DES) films showed a higher diagnostic ...

2009-02-01

59

Feasibility of ultra-low-dose multislice CT colonography for the detection of colorectal lesions: preliminary experience  

Energy Technology Data Exchange (ETDEWEB)

Our objective was to evaluate the feasibility of ultra-low-dose scanning for multislice CT colonography in the detection of colorectal lesions. Twenty-seven patients (14 men, 13 women) with clinical indication for conventional colonoscopy were recruited. Multislice spiral CT (Somatom Plus 4 Volume Zoom, Siemens, Germany) examinations were performed after standard oral colonoscopic preparation and colonic distension with room air. Images were acquired using 2.5-mm collimation, 3.0-mm slice thickness, standard reconstruction kernel, 140 kVp, and 10 mAs. Supine and prone acquisitions were obtained in all patients. Images were analyzed on a workstation by two gastrointestinal radiologists. Conventional colonoscopy was performed on the same day in all patients and represented the standard of reference. Total radiation exposure was also calculated. All colorectal cancers were correctly identified at CT colonography (9 of 9, sensitivity 100%). The CT ...

2003-06-01

60

Simultaneous assessment of left ventricular function from gated myocardial perfusion SPECT. Utility of QGS (Quantitative Gated SPECT) program  

International Nuclear Information System (INIS)

Quantitative gated SPECT (QGS) was evaluated in 7 normal volunteers and 31 patients with cardiac diseases. Adequate cut off value of a prefilter was 0.45. In phantom, the left ventricular volume value was 93.9% of determined value by 180-degree projection in L type and 98.8% by 360-degree projection in opposed type. In normal volunteers, LVEF measured by QGS program related to value by first pass method. As for functional map, regional EF and wall motion decreased at the septum side, and wall thickening at base side of heart. Good correlation was recognized (p<0.0001) between blood flow image and functional map (regional EF and wall thickening). In 20 cases of acute myocardial infarction, lesion was detected conspicuously in regional EF and wall motion. The accuracy of coronary arterial stenosis improved in functional map (regional EF 92%, wall motion 92% and wall thickening 88%). In particular, the accuracy of 3 rami ...

1998-08-01

61

Magnetic resonance imaging: early detection of central nervous system involvement in acquired immunodeficiency syndrome (AIDS)  

International Nuclear Information System (INIS)

Central Nervous System (CNS) involvement, whether primary by the Human Immunodeficiency Virus - HIV - itself, or secondary (toxoplasmosis or lymphoma) is remarkably frequent in AIDS, in 40 to 70% of cases, depending upon the author. In order to study the natural history of this illness, a cohort of 25 asymptomatic seropositive patients have been established. Every 6 months these patients undergo biological and clinical examinations, as well as Magnetic Resonance brain scans. After two examinations at a 6 month's interval, the first results are reported. Out of these 25 cases, 9 present anomalies: One patient with diffuse cerebral atrophy and 8 others with high signal intensity areas on T2 weighted sequences, like those of the Multiple Sclerosis. No relationship could be demonstrated between the existence of these lesions and various criteria such as age, sex, risk factors and T4 cells count. The nature of these lesions is not lear. They ...

62

Imaging Ewing's sarcoma  

International Nuclear Information System (INIS)

Ewing's sarcoma is a highly malignant neoplasm of the bone whose origin is still uncertain. A strong relationship exists between Ewing's sarcoma and tumors of neural origin (Ewing family of tumors). Ewing's sarcoma must be distinguished from other round-cell tumors like lymphoma and neuroblastoma and also must be differentiated from osteogenic sarcomas. On plain radiographs, Ewing's sarcoma appears as a lytic or mixed lytic-sclerotic, rarely as predominantly sclerotic lesion with margins Lodwick grade III. It is located primarily in the diaphyseal and metadiaphyseal regions of the long bones of the lower extremities. A large soft tissue tumor is usually present. Magnetic resonance imaging is the imaging modality of choice to evaluate the extent of the primary lesion, to monitor the response to neoadjuvant chemotherapy and to follow up non-resected Ewing's sarcomas. Bone scintigraphy is necessary to detect skeletal ...

1998-06-01

63

DNA alterations photosensitized by tetracycline and some of its derivatives  

Energy Technology Data Exchange (ETDEWEB)

Bacteriophage M13 mp10 DNA were irradiated with near-UV light in the presence of tetracycline derivatives and primed with synthetic oligonucleotide to be used for DNA synthesis using Escherichia coli DNA polymerase. Chain terminations were observed by denaturing polyacrylamide gel electrophoresis and mapped precisely. All the synthesis stops occurred before or at the level of guanine residues, showing that the photoreaction mediated by tetracycline derivatives led to a preferential alteration of guanine residues. These lesions were demonstrated to be induced in DNA through a pathway involving singlet oxygen. Tetracycline derivatives also photoinduced the breakage of the DNA sugar-phosphate backbone monitored by the conversion of supercoiled phi X174 DNA to a relaxed form. This lesion was shown to be initiated by hydroxyl radicals. The production of this free radical has been confirmed by electron paramagnetic resonance (EPR) spin trapping ...

1986-06-01

64

Cyst-like cortical tubers in patients with tuberous sclerosis complex: MR imaging with the FLAIR sequence  

Energy Technology Data Exchange (ETDEWEB)

Tuberous sclerosis complex (TSC) is an inherited disorder characterized by the presence of cortical tubers, the majority of which are solid and show high signal on FLAIR images. Low-signal tubers are less frequent. To evaluate cystic cortical tubers in patients with TSC on the basis of their appearance on FLAIR images. MR examinations of 73 patients were retrospectively reviewed and 17 children (aged 25 days to 12.3 years) with a typical cyst-like tubers were selected for further analysis. The age of the patients, the number of lesions, and the shape and MR intensity were analyzed. Cyst-like cortical tubers were detected in 82% of children below 7 years of age and in 18% of those older then 7 years (P=0.00086). Most of the cystic lesions were of the shrunken type (72%), the expansile type being less frequently seen (28%). FLAIR images confirm the cystic character of some of the cortical tubers in TSC patients although the ...

2006-06-15

65

An evaluation of low-dose single-slice helical CT in pulmonary CT scan  

International Nuclear Information System (INIS)

Objective: To investigate the feasibility of low-dose single-slice helical CT in pulmonary CT scan and evaluate the clinical application. Methods: Thirteen cases were selected out of 132 cases, in which low-dose (50mAs) single-slice helical CT scan of chest was performed. This set of cases included 7 cases of multiple metastatic nodules; 3 of solitary pulmonary, nodule; and 3 of pulmonary patchy lesions. Regular dose (170mAs) CT scan was also performed on all those patients. The regular dose and low dose CT scan were compared on sensitivity of detecting the lesions; the performance in demonstrating the details of the abnormalities; and the capability of revealing the segmental bronchi as well. Results: The same number and size of the pulmonary nodules were revealed with scan modalities loaded with different doses. No significant difference in demonstrating the details of the nodules and the segmental bronchi was found ...

2006-04-01

66

Incidence of lesions as described by MRI in focal epilepsy of frontal and temporal onset; Inzidenz kernspintomographisch erfassbarer Laesionen bei der Abklaerung fokaler Epilepsien frontalen und temporalen Ursprunges  

Energy Technology Data Exchange (ETDEWEB)

Aim: Today, MRI is an integral part of the presurgical evaluation of patients suffering from partial epilepsy. These patients frequently show focal morphological abnormalities with potential epileptogenic character and surgical resection of these lesions is associated with superior postsurgical outcome as to seizure frequency. Apart from easily detectable defects, such as post-traumatic lesions or cerebral infarction, as wide variety of mainly small abnormalities can be detected using MRI. Methods: In this study, 484 patients suffering from partial epilepsy of temporal or frontal onset were evaluated for the incidence of different lesions in this population. Results: All lesions found were included without evaluating their potential epileptogenicity, which remains to be proven using other procedures (EEG, SPECT, PET, etc.). Involvement of the hippocampal ...

1997-09-01

67

Modern imaging methods for diagnostic evaluation of tumors of the oropharynx and the oral cavity; Moderne bildgebende Methoden bei der Diagnostik von Tumoren des Oropharynx und der Mundhoehle  

Energy Technology Data Exchange (ETDEWEB)

Differentiating a benign from a malignant lesion by information such as density data, or signal intensities or echo gradients, is not possible with CT, nor MRI, nor ultrasonography. Only some lesions show characteristic signs. Inflammations cannot be difscriminated from malignant tumors. CTs of small tumors in particular are so poor in contrast that it is much more difficult to detect tumors or discriminate them from other lesions, as compared to MR images or ultrasonographs. CT does not detect surface tumors, but is more sensitive than MRI or US in detecting discrete cortical bone lesions. The same applies to small calcified tumors. MRI however is most sensitive in detecting tumor volumes in the yellow marrow, and is the best modality for evaluation of extraossal extension of tumors. CT yields better results than MRI if ...

1996-11-01

68

Tracheal images using energy subtraction Fuji computed radiography  

International Nuclear Information System (INIS)

Twenty patients with lesions in the trachea or bronchus underwent energy subtraction Fuji computed radiography (FCR). Images obtained were compared with those from conventional FCR (plain FCR). ''Very clear'' images (in which the contour of the trachea and bronchus could be clearly defined) were obtained in 12/22 (55 %) by energy subtraction FCR and in 3/22 (14 %) by plain FCR; ''clear'' images (in which the contour could be defined) in 9/22 (41 %) by energy subtraction FCR and in 18/22 (82 %) by plain FCR; and ''unclear'' images (in which the contour could not be defined) in 1/22 (5 %) by both methods. Energy subtraction FCR, as well as plain FCR, yielded high image quality for the trachea. Energy subtraction FCR was superior to plain films when tumors existed within the trachea. (Namekawa, K.).

1985-01-01

69

Comparison of high resolution whole-body MRI using parallel imaging and PET-CT. First experiences with a 32-channel MRI system  

International Nuclear Information System (INIS)

To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI scanner (Magnetom Avanto, Siemens Medical Solutions) with a total field of view of 205 cm and free table ...

70

Tetracycline ulcers of the oesophagus  

Energy Technology Data Exchange (ETDEWEB)

Two cases of tetracycline ulcers of the oesophagus are reported and compared with thirteen other cases from the literature. In most cases, the patients had taken their capsules with little or no fluid just before going to bed. Some hours later they developed retrosternal pain that was intensified by swallowing. Endoscopy showed sharply demarcated greyish-white areas of mucosal damage which represented layers of stratified squamous cells, separated by oedema, and a dense neutrophilic infiltration of the lamina propria and the muscularis mucosa. Roentgenology was unsuitable to detect the lesions. They healed without complications within one to six weeks. Prolonged retention of the capsules in the oesophagus is thought to cause the mucosal damage. Patients on oral tetracycline or doxycycline treatment should therefore be instructed to take their capsules with a meal or with copious water and not just before going to bed.

1981-11-01

71

Early-stage focal nodular hyperplasia: US/CT/MR features correlated with histology  

Energy Technology Data Exchange (ETDEWEB)

Two cases of focal nodular hyperplasia (FNH), in which ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MR) studies detected an atypical hemorrhagic pattern associated with an intrahepatic arterio venous malformation (AVM) around the growths, are presented. In both cases, histology demonstrated a very early regenerative stage and necrotic-hemorrhagic areas within the lesions. In these cases, the analysis of radiological findings, surgical specimens and histology seemed to confirm the pathogenetic hypothesis suggested by Wanless: in normal liver parenchyma, a ``blood steal`` phenomenon due to congenital or acquired intrahepatic AVM could cause ischemic damage, appearing as a hemorrhagic necrotic area, the extent of which depends on the degree of residual portal supply. (orig.)

1994-02-01

72

Borrelia Burgdorferi ''sensu lato'' in Brazil: Occurrence confirmed by immunohistochemistry and focus floating microscopy  

British Library Electronic Table of Contents (United Kingdom)

In the present study, we report the occurrence of Lyme's borreliosis in patients from the Brazilian Amazon Region. Borreliosis was investigated by immunohistochemistry and focus floating microscopy for Borrelia burgdorferi in skin biopsy samples from 22 patients with both clinical and histopathology evidences compatible with Erythema Migrans. Spirochetes were detected by specific immunohistochemistry and focus floating microscopy for B. burgdorferi in samples from five patients. Clinical cure of the cutaneous lesions was observed in all the patients after treatment with doxycycline regimen as proposed by the Center Disease Control guidelines. A limitation of our study was the fact that we were not able to isolate and culture these organisms. These are the first known Brazilian cases of bor...

2010-01-01

73

Dynamic construction of outage lists for safety analysis of power transmission lines. Dynamische Erstellung von Ausfallisten fuer die Sicherheitsanalyse elektrischer Energieuebertragungssysteme  

Energy Technology Data Exchange (ETDEWEB)

An adaptive contingency selection process is set up which produces outage lists in order to guarantee on-line network security control. The quality index system used so far did not detect and reveal all critical variables due to observation problems in the mapping of two functions. The new process uses the results of the outage simulation computing of the system status just past for the drawing up of an up-to-date outage list. A linear correcting function transform the G{sub 2}-values of the standard quality index method - which still incorporate the observation problem effect - into improved values G. Studies which use data from realstic high-voltage networks prove that the detection of critical variables is far superior to ordinary methods. (orig.).

1990-04-23

74

The management of pain following laminectomy for lumbar disc lesions.  

UK PubMed Central (United Kingdom)

Assessment of the results of laminectomy for lumbar disc lesions is unsatisfactory, but it seems that some degree of recurrent pain is virtually inevitable. The clinical features and incidence of the...Full Text Available

1981-07-01

75

Neurocysticercosis  

UK PubMed Central (United Kingdom)

A single enhancing lesion in the brain parenchyma, also called an inflammatory granuloma, is a frequent neurologic diagnosis. One of the commonest causes of this lesion is human neurocysticercosis,...Full Text Available

2010-08-17

76

Necrotizing sialometaplasia of tongue  

UK PubMed Central (United Kingdom)

Necrotizing sialometaplasia, is a benign inflammatory lesion primarily involving the minor salivary glands of the hard palate. The lesion often presents itself as a deep-seated palatal ulcer with clinical...Full Text Available

2009-01-01

77

Foveo-macular retinitis, solar retinopathy, and trauma.  

UK PubMed Central (United Kingdom)

Three patients are described with foveal lesions resembling minute holes following trauma. The similarity of the lesions to foveomacular retinitis and solar retinopathy suggests that all these conditions...Full Text Available

1978-08-01

78

Multi-modality imaging of uveal melanomas using combined PET/CT, high-resolution PET and MR imaging  

Energy Technology Data Exchange (ETDEWEB)

We investigated the efficacy of combined FDG-PET/CT imaging for the diagnosis of small-size uveal melanomas and the feasibility of combining separate, high-resolution (HR) FDG-PET with MRI for its improved localization and detection. Patients, methods: 3 patients with small-size uveal melanomas (0.2-1.5 ml) were imaged on a combined whole-body PET/CT, a HR brain-PET, and a 1.5 T MRI. Static, contrast-enhanced FDG-PET/CT imaging was performed of head and torso with CT contrast enhancement. HR PET imaging was performed in dynamic mode 0-180 min post-injection of FDG. MRI imaging was performed using a high-resolution small-loop-coil placed over the eye in question with T2-3D-TSE and T1-3D-SE with 18 ml Gd-contrast. Patients had their eyes shaded during the scans. Lesion visibility on high-resolution FDGPET images was graded for confidence: 1: none, 2: suggestive, 3: clear. Mean tumour activity was calculated for summed image frames that resulted ...

2008-07-01

79

Methodology for designing air-quality-monitoring networks. 1. Theoretical aspects  

Energy Technology Data Exchange (ETDEWEB)

An objective methodology is presented for determining the number and disposition of ambient air-quality stations in a monitoring network for the primary purpose of compliance with air-quality standards. The methodology utilizes a data base with real or simulated data from an air quality dispersion model for application with a two-step process for ascertaining the optimal monitoring network. In the first step, the air-quality patterns in the data base are collapsed into a single composite pattern through a figure-of-merit (FOM) concept. The most-desirable locations are ranked and identified using the resultant FOM fields. In the second step the network configuration is determined on the basis of the concept of spheres of influence (SOI) developed from cutoff values of spatial-correlation coefficients between potential monitoring sites and adjacent locations. The minimum number of required stations is ...

1986-01-01

80

Imaging of dialysis-related amyloid (AB-amyloid) deposits with sup 131 I-beta 2-microglobulin  

Energy Technology Data Exchange (ETDEWEB)

The diagnosis of dialysis-related amyloid (AB-amyloid) has been based usually on clinical and radiological criteria. Following the discovery that beta 2-microglobulin was the major protein of this amyloid, we isolated and radiolabelled uremic plasma beta 2-microglobulin. After intravenous injection, gamma-camera images of selected joint areas were obtained from 42 patients who were on regular hemodialysis therapy. Positive scans involving the shoulder, hip, knee and carpal regions were found in 13 of 14 patients treated for more than 10 years and 10 of 16 patients treated for 5 to 10 years. Patients treated for less time had negative scans. Specificity was indicated by negative scans in non-amyloid inflammatory lesions in control hemodialysis patients. Up to 48-fold tracer enrichment was detected in excised AB-amyloid containing tissue as compared to amyloid-free tissue. These findings suggest that circulating radiolabelled beta 2-microglobulin ...

1990-12-01

81

Adenosine triphosphate loading thallium-201 myocardial scintigraphy. Optimal dose and diagnostic accuracy  

Energy Technology Data Exchange (ETDEWEB)

Adenosine triphosphate (ATP) is an alternative to dipyridamole or adenosine in thallium-201 myocardial scintigraphy. However, the optimal dose of ATP has not been determined. A Doppler guide wire study showed the coronary flow velocity at a dose of 0.15 mg/kg of ATP was equal or higher than that at 0.14 mg/kg of adenosine or 0.56 mg/kg of dipyridamole. ATP was given intravenously to 67 patients with coronary artery disease at 0.15 mg/kg/min for 6 min. Thallium-201 was injected at 3 min, followed by immediate and delayed (3 hrs) tomographic imaging. There was no serious side effect during examination, although chest pain (26%), dyspnea (17%), and flushing (33%) were common. The sensitivity and specificity to detect coronary artery disease were 98 and 100%, respectively. The sensitivity to detect left anterior descending artery, left circumflex artery, and right coronary artery lesions was 94, 59 and 77%, respectively. ATP ...

1995-01-01

82

Ultrasonography and Computerized Tomography in the diagnosis of complex abdominal lesions  

International Nuclear Information System (INIS)

Complex abdominal lesions include a variety of pathologies, such as septated, infected, and hemorrhagic cysts, abscesses, tumors, and fluid collections of different ethiology. These lesions present diagnostic difficulties with both Ultrasonography (US) and Computed Tomography (CT), since findings may not be present or, when present, are not specific. Keeping these limitations in mind, we evaluated 105 patients (111 abdominal lesions) with both US and CT in order to compare their adequacy in predicting the nature of the lesion. On the basis of US and CT results, complex abdominal lesions were divided in four classes: class I includes 43 cases in which both examinations gave the same contribution to the definition of the nature of the lesion, class II (14 lesions, mainly sperimentated cysts), in which US was superior to CT, class III includes ...

1988-01-01

83

Feasibility study of computed tomography colonography using limited bowel preparation at normal and low-dose levels study  

Energy Technology Data Exchange (ETDEWEB)

The purpose was to evaluate low-dose CT colonography without cathartic cleansing in terms of image quality, polyp visualization and patient acceptance. Sixty-one patients scheduled for colonoscopy started a low-fiber diet, lactulose and amidotrizoic-acid for fecal tagging 2 days prior to the CT scan (standard dose, 5.8-8.2 mSv). The original raw data of 51 patients were modified and reconstructed at simulated 2.3 and 0.7 mSv levels. Two observers evaluated the standard dose scan regarding image quality and polyps. A third evaluated the presence of polyps at all three mSv levels in a blinded prospective way. All observers were blinded to the reference standard: colonoscopy. At three times patients were given questionnaires relating to their experiences and preference. Image quality was sufficient in all patients, but significantly lower in the cecum, sigmoid and rectum. The two observers correctly identified respectively ...

2007-12-15

84

Programmable radionuclide X-ray fluorescence multi-channel spectrometric analyzer, type 123-1  

International Nuclear Information System (INIS)

The whole equipment consists of three separate portable parts: a detector case, a microprocessor and a graphic TV monitor. Magnetic tape memory and an x-y recorder can be connected for recording the measured spectra. The analyzer contains two built-in exchangeable excitation radionuclides. Fluorescence and scattered radiation is detected using a proportional detector. The detected pulses are analyzed by a 256-channel analyzer and the results are shown on the display. The device may be used in mining laboratories, coal and ore dressing plant control rooms or in mining fields of open cast mines for quick detection of the quality of mined or dressed raw materials. (E.S.). 1 fig.

1988-01-01

85

Real-time monitoring of dosimetry and image quality during digital radiology examinations  

International Nuclear Information System (INIS)

Objective: To explore the feasibility of real-time monitoring exposure dose and image quality by using the data stored in the DICOM image archive of direct digital radiography system. Methods: Model TO. 16 was exposed, the current increased gradually from 0.5 to 125 mAs. The displayed number of model A( diameter 11.1 mm), D (diameter 4.0 mm) and J( diameter 0.7 mm) were recorded, and the detect factors (H_T) was also calculated. Images were sent to workstation before the end of DR examination. An automatic procedure was implemented to extract dose data and exposure parameters from the DICOM header file. Maximum, minimum and 3rd quartile values were preinstalled. Mean values exceeding the threshold trigger alarm signal to guide radiologist to explore the cause. Results: When the current of point A was less than 10 mAs and the current of point D and J were less than 16 mAs, the detect factor (H_T) increased with the rise of ...

2009-12-01

86

Quality engineering and control. Annual progress report, January-December 1981  

International Nuclear Information System (INIS)

Brief summaries are given of research carried out in the following areas: absorption spectroscopy of titanium, niobium, and molybdenum in uranium alloys; atomic absorption spectroscopy of selenium in stainless steel, computer program improvements for spectrophotometer control, and detection of beryllium in stack gases; electrolysis for inactivation of bacteria in cooling-tower water; improved solvent analysis by gas chromatography; sequential radionuclide separation for various sample matrices; progress on an electron microprobe analyzer; and miscellaneous projects.

87

Groundwater quality assessment plan for single-shell tank waste management Area U at the Hanford Site  

Energy Technology Data Exchange (ETDEWEB)

Waste Management Area U (WMA U) includes the U Tank Farm, is currently regulated under RCRA interim-status regulations, and is scheduled for closure probably post-2030. Groundwater monitoring has been under an evaluation program that compared general contaminant indicator parameters from downgradient wells to background values established from upgradient wells. One of the indicator parameters, specific conductance, exceeded its background value in one downgradient well triggering a change from detection monitoring to a groundwater quality assessment program. The objective of the first phase of this assessment program is to determine whether the increased concentrations of nitrate and chromium in groundwater are from WMA U or from an upgradient source. Based on the results of the first determination, if WMA U is not the source of contamination, then the site will revert to detection monitoring. If WMA U is the source, then a ...

2000-03-21

89

State-of-the-art techniques for internal quality measurements in steel sheets production processes; Hakkoban seizo ni okeru naibu hinshitsu no onrain keisoku oyobi kensa gijutsu  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the state-of-the-art ultrasonic and magnetic measuring techniques developed at Kawasaki Steel and used in the production process of steel sheets are described. Representative examples shown here are as follows: (1) Magnetic flux leakage testing system for the detection of nonmetallic inclusions, (2) Nondestructive orientation measurement for secondary re-crystallized grains in grain-oriented electrical steel by ultrasonic interferometry, (3) Immersion testing method for the detection of nonmetallic inclusions, (4) Surface wave probe for the detection of surface flaws in rolls used in rolling mills. Developments of these techniques and their applications to actual steel sheets production processes have contributed to advance in technologies for quality assurance and control. With the help of these techniques, steel sheet products with advanced and uniform properties are being continuously ...

1999-12-01

90

Staging of osteochondritis dissecans of the knee and ankle with MRI. Comparison with conventional radiography and arthroscopy  

International Nuclear Information System (INIS)

A prospective study was performed on 50 patients suffering from osteochondritis dissecans of the knee and ankle to define criteria for stability and fixation of osteochondral lesions. Morphological parameters in MRI (size, fragmentation, cartilage, interface) and conventional radiology (separation, fragmentation) were registered and compared with arthroscopical staging. MRI staging based on different types of interfaces was demonstrated on T_1- and T_2-weighted images. MRI could correctly predict a Grade 1 lesion in 50%, a Grade 2 lesion in 90%, a Grade 3 lesion on 0%, and a Grade 4 lesion in 79%. Stable lesions were differentiated from unstable lesions in 90%. Radiographic findings corresponded with arthroscopic staging in only 56% of the cases because fibrotic connection may guarantee stability in case of bony separation. (orig./MG).

91

DNA rearrangements from #gamma#-irradiated normal human fibroblasts preferentially occur in transcribed regions of the genome  

International Nuclear Information System (INIS)

Full text: DNA rearrangement events leading to chromosomal aberrations are central to ionizing radiation-induced cell death. Although DNA double-strand breaks are probably the lesion that initiates formation of chromosomal aberrations, little is understood about the molecular mechanisms that generate and modulate DNA rearrangement. Examination of the sequences that flank sites of DNA rearrangement may provide information regarding the processes and enzymes involved in rearrangement events. Accordingly, we developed a method using inverse PCR that allows the detection and sequencing of putative radiation-induced DNA rearrangements in defined regions of the human genome. The method can detect single copies of a rearrangement event that has occurred in a particular region of the genome and, therefore, DNA rearrangement detection does not require survival and continued multiplication of the affected cell. ...

2003-08-17

92

Assessment of the effects of pixel loss on image quality in direct digital radiography  

Energy Technology Data Exchange (ETDEWEB)

Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. ...

2004-03-21

93

Assessment of the effects of pixel loss on image quality in direct digital radiography  

International Nuclear Information System (INIS)

Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. Measurement of the MTF, NPS and DQE can ...

2004-03-21

94

Digital luminescent radiography: A substitute for conventional chest radiography?  

International Nuclear Information System (INIS)

The image quality of digital luminescent radiography (DLR) is sufficient for routine biplane chest radiography and for follow-up studies of heart size, pulmonary congestion, coin lesions, infiltrations, atelectasis, pleural effusions, and mediastinal and hilar lymph node enlargement. Chest radiography in the intensive care unit may in most cases be performed using the DLR technique. there is no need for repeat shots because of incorrect exposure, and the position of catheters, tubes, pacemakers, drains and artificial heart valves, the mediastinum, and the retrocardiac areas of the left lung are more confidently assessed on the edge-enhanced DLR films than on conventional films. Nevertheless, DLR is somewhat inferior to conventional film-screen radiography of the chest as it can demonstrate or rule out subtle pulmonary interstitial disease less confidently. There is no reduction of radiation exposure of the chest in DLR compared with modern ...

95

Computed radiography for major airway in pediatrics  

International Nuclear Information System (INIS)

This paper shows the efficacy of computed radiography for major airway in pediatrics. For this purpose, we examined 40 children (range 2 weeks to 14 years; mean 2.3 years) using Fuji Computed Radiography (FCR) and radiation dose using pediatric phantom under FCR and conventional film and screen system. In comparison study with FCR and conventional film and screen system, FCR images are superior to conventional system in all cases. Scorings were done for the quality of the image of the pharynx, the trachea, and both main bronchi. In phantom study to check radiation dose, radiation dose could be reduced 1/6 of the value using high speed film and screen and 1/15 of the value using conventional speed film and screen. FCR also showed clear airway images in all cases but technical failure to evaluate the clinical lesion. These results suggest that FCR is the adequate imaging modality to evaluate the major airway in children. (author).

1986-01-01

96

Myocardial imaging in patients with Kawasaki disease. Exercise stress imaging and serial studies  

Energy Technology Data Exchange (ETDEWEB)

Thallium-201 myocardial imaging was performed in 80 children with coronary arterial lesions due to Kawasaki disease in order to assess the value of serial and exercise myocardial imagings. In eight of these children, abnormalities of the image were noted. Twenty children had serial thallium studies with an interval of three to 18 months, and five of these showed changes in the image including appearance of a new perfusion defect in one patient and improvement of perfusion defects in four. These changes of the myocardial image were correlated well with coronary angiographic findings obtained within a few days of the isotope studies. It was noted that the changes of the myocardial image were more frequently observed at relatively recent period recovered from Kawasaki disease. Exercise myocardial imaging using a bicycle ergometer was performed in eight children with coronary arterial lesions. In three an evidence of improvement of the myocardial ...

1982-06-01

97

Model for predicting the effects of laser exposures and eye protection on vision. Interim report, January 1989-January 1990  

Energy Technology Data Exchange (ETDEWEB)

Laser safety standards and eye protection (filters) are designed to limit ocular exposures to prevent retinal lesions, yet eyesafe laser exposures can disrupt vision by causing glare and flashblindness. Protective filters can have opposing effects on vision function. They reduce laser exposures but also reduce task luminance and contrast. Filters alone may interfere with vision and consequently reduce work safety and performance. It is therefore important to be able to predict the effects of both laser exposures and protective filters to assess trade-offs between protection and visual function. This paper briefly reviews the methods, concepts, and experimental database used in our laboratory to predict laser, filter, and laser-plus-filter effects on tasks involving visual detection. The modeling approach uses estimates of the spatial distribution of light in the retinal image of the laser source to predict glare, flashblindness, and retinal ...

1990-01-01

98

Lesion localization in patients with hyperparathyroidism using double-phase Tc-99m MIBI parathyroid scintigraphy  

International Nuclear Information System (INIS)

This study was performed to evaluate the diagnostic usefulness of double-phase Tc-99m MIBI parathyroid scintigraphy with single photon emission computed tomography (SPECT) in patients with hyperparathyroidism. We also evaluated the relationship between Tc-99m MIBI uptake and oxyphil cell contents in parathyroid glands. The subjects were 28 parathyroid glands of 10 patients who underwent Tc-99m MIBI parathyroid scintigraphy and parathyroidectomy for clinically suspected hyperparathyroidism. Early and delayed pinhole images were obtained at 15 minutes and 2 hours after injection of Tc-99m MIBI, and SPECT images were followed. The weight and oxyphil cell contents of parathyroid tissue were obtained from pathologic specimen, and the scintigraphic findings were compared with histopathology. In surgical histopathology, 6 parathyroid adenomas and 9 parathyroid hyperplasias were confirmed. The sensitivity, specificity, and positive predictive value of early and delayed images were 46.7% ...

1999-02-01

99

Clinical Experiences With Onboard Imager KV Images for Linear Accelerator-Based Stereotactic Radiosurgery and Radiotherapy Setup  

International Nuclear Information System (INIS)

Purpose: To report our clinical experiences with on-board imager (OBI) kV image verification for cranial stereotactic radiosurgery (SRS) and radiotherapy (SRT) treatments. Methods and Materials: Between January 2007 and May 2008, 42 patients (57 lesions) were treated with SRS with head frame immobilization and 13 patients (14 lesions) were treated with SRT with face mask immobilization at our institution. No margin was added to the gross tumor for SRS patients, and a 3-mm three-dimensional margin was added to the gross tumor to create the planning target volume for SRT patients. After localizing the patient with stereotactic target positioner (TaPo), orthogonal kV images using OBI were taken and fused to planning digital reconstructed radiographs. Suggested couch shifts in vertical, longitudinal, and lateral directions were recorded. kV images were also taken immediately after treatment for 21 SRS patients and on a weekly basis for 6 SRT ...

2009-02-01

100

Geometrically anisotropic probes: an improved eddy current technique  

Energy Technology Data Exchange (ETDEWEB)

Geometrically anisotropic eddy current probes are a type of separate function probes especially fit to the detection of defects showing a preferential direction. This kind of flaw induces a coupling between the transmitter and the receiver by guiding eddy currents from the one to the other. On the other hand, this coupling will be almost non-existent in the presence of defects or spurious effects not displaying this geometrical particularity. Basic studies on an elementary two-coil set-up allow the acknowledgment of the intrinsic qualities of such probes: good signal-to-noise ratio, influence field practically constant on the whole defect length, ability to detect bridged defects, insensitivity to lift off. These results can be improved by achieving multicoils probes adapted to different kinds of problems. An application to continuous casting slabs testing yields very interesting results in the ...

1987-06-01

101

Preparatory Signal Detection for Annex I Countries under the Kyoto Protocol. A Lesson for the Post-Kyoto Policy Process  

Energy Technology Data Exchange (ETDEWEB)

The focus of this study is on the preparatory detection of uncertain net greenhouse gas (GHG) emission changes (also termed emission signals) under the Kyoto Protocol. The crucial question to be addressed is: How well do we need to know net emissions if we want to detect a specified emission signal after a given time? No restrictions exist as to what concerns the net emitter, which may be any GHG source or sink. Annex I countries are chosen as net emitters, simply for reasons of data availability and because of the excellent possibility of comparing net emitters (inter-country comparison). The countries' emissions - in an increasing number of cases even their uncertainties - are available permitting the application of preparatory signal detection techniques, which are suited to address the aforementioned question. We currently discuss four hierarchically-ordered detection concepts to assess ...

2004-06-14

102

Reduction of fluoroscopic exposure for the air-contrast barium enema  

Energy Technology Data Exchange (ETDEWEB)

In a fluoroscopic imaging system, image quality and patient dose are both affected by the optical system linking the image intensifier with the video camera. The effect on patient exposure of increasing the optical iris aperture size over that required for other procedures performed on the same imaging system was investigated for the air-contrast barium enema examination. Using a large-area transmission ionisation chamber to monitor the Roentgen-area-product of entrance exposure, a decrease in fluoroscopic radiation of greater than 50% was clinically documented for a fluoroscopic system utilising kVp and mA variable automatic brightness control. For this iris change, the video image was of acceptable quality for positioning and monitoring the patient, and no deleterious effect was detected in the conduct of the air-contrast exam. The availability of a variable-sized operator-selectable iris diaphragm would permit this ...

1983-11-01

103

A facile and green preparation of high-quality CdTe semiconductor nanocrystals at room temperature  

Energy Technology Data Exchange (ETDEWEB)

One chemical reagent, hydrazine hydrate, was discovered to accelerate the growth of semiconductor nanocrystals (cadmium telluride) instead of additional energy, which was applied to the synthesis of high-quality CdTe nanocrystals at room temperature and ambient conditions within several hours. Under this mild condition the mercapto stabilizers were not destroyed, and they guaranteed CdTe nanocrystal particle sizes with narrow and uniform distribution over the largest possible range. The CdTe nanocrystals (photoluminescence emission range of 530-660 nm) synthesized in this way had very good spectral properties; for instance, they showed high photoluminescence quantum yield of up to 60%. Furthermore, we have succeeded in detecting the living Borrelia burgdorferi of Lyme disease by its photoluminescence image using CdTe nanocrystals.

2008-06-18

104

Value of micro-CT as an Investigative Tool for Osteochondritis Dissecans. A preliminary study with comparison to histology  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate micro computed tomography (micro-CT) for the assessment of osteochondritis dissecans in comparison with histology. Material and Methods: Osteochondritis dissecans lesions of 3 patients were evaluated using micro-CT (0.125 mA, 40 keV, 60 m slice thickness, 60 m isotropic resolution, entire sample) and light microscopy (toluidine blue, 3-5 m slice thickness). The methods were compared regarding preparation time, detectability of tissue types and morphologic features of bone and cartilage. Results: Non-destructive micro-CT imaging of the entire sample was faster than histologic preparation of a single slice for light microscopy. Morphologic features of bone and cartilage could be imaged in a comparable way to histology. It was not possible to image cells or different tissue types of bone and cartilage with micro-CT. Conclusion: Micro-CT is a fast, non-destructive tool that may be a supplement or, if detailed histologic ...

2003-09-01

105

Value of micro-CT as an Investigative Tool for Osteochondritis Dissecans. A preliminary study with comparison to histology  

International Nuclear Information System (INIS)

Purpose: To evaluate micro computed tomography (micro-CT) for the assessment of osteochondritis dissecans in comparison with histology. Material and Methods: Osteochondritis dissecans lesions of 3 patients were evaluated using micro-CT (0.125 mA, 40 keV, 60 m slice thickness, 60 m isotropic resolution, entire sample) and light microscopy (toluidine blue, 3-5 m slice thickness). The methods were compared regarding preparation time, detectability of tissue types and morphologic features of bone and cartilage. Results: Non-destructive micro-CT imaging of the entire sample was faster than histologic preparation of a single slice for light microscopy. Morphologic features of bone and cartilage could be imaged in a comparable way to histology. It was not possible to image cells or different tissue types of bone and cartilage with micro-CT. Conclusion: Micro-CT is a fast, non-destructive tool that may be a supplement or, if detailed histologic ...

2003-09-01

106

Solid-pseudopapillary tumor of the pancreas in a 13-year-old girl - case report  

International Nuclear Information System (INIS)

The solid-pseudopapillary tumor (SPT) of the pancreas is a rare type of exocrine pancreatic neoplasm. SPT predominantly affects young women and female children, and is usually discovered incidentally. This tumor is generally benign with a low incidence of malignancy. A 13-year-old girl was admitted to the hospital with a few weeks' history of mild abdominal pain and jaundice. On physical examination, there was no palpable mass. The laboratory tests showed increased SR, CRP, high bilirubin, amylase and lipase serum levels. Ultrasound imaging revealed a solid lesion in the region of the pancreatic head. On MRI, precise tumor localization in the head of the pancreas with pancreatic duct dilatation and compression of the common bile duct were visualized. Pancreaticoduodenectomy and cholecystectomy was performed with good clinical outcome. Microscopic and immunohistochemical studies indicated that tumor cells were typical of SPT without any signs of malignancy. After ...

107

Large intracranial vessel occlusion arising after radiotherapy for craniopharingioma. A case report and review of the literature  

Energy Technology Data Exchange (ETDEWEB)

We report a patient who developed occlusion of the intracranial major arteries induced by radiation therapy for craniopharyngioma. The patient, a 9-year-old boy, presented with deterioration of vision, nausea and vomiting. He underwent a right ventriculo-peritoneal shunt operation, and the tumor was partially removed. Postoperatively, he received focal radiation therapy with total of 60 Gy. Preoperative cerebral angiography, cerebral vessels had no sigh of occlusive lesion or stenosis. One year after irradiation, he started to have repeated cerebral ischemic attacks. But no regrowth of the tumor was detected on CT scans. Two years and 8 months after irradiation, he suddenly had right hemiparesis. Cerebral angiography revealed severe stenosis of the right anterior cerebral artery (precommunicating segment), middle cerebral artery (horizontal portion) and terminal portion of the right carotid artery. Left carotid angiography showed complete ...

1994-10-01

108

Large intracranial vessel occlusion arising after radiotherapy for craniopharingioma. A case report and review of the literature  

International Nuclear Information System (INIS)

We report a patient who developed occlusion of the intracranial major arteries induced by radiation therapy for craniopharyngioma. The patient, a 9-year-old boy, presented with deterioration of vision, nausea and vomiting. He underwent a right ventriculo-peritoneal shunt operation, and the tumor was partially removed. Postoperatively, he received focal radiation therapy with total of 60 Gy. Preoperative cerebral angiography, cerebral vessels had no sigh of occlusive lesion or stenosis. One year after irradiation, he started to have repeated cerebral ischemic attacks. But no regrowth of the tumor was detected on CT scans. Two years and 8 months after irradiation, he suddenly had right hemiparesis. Cerebral angiography revealed severe stenosis of the right anterior cerebral artery (precommunicating segment), middle cerebral artery (horizontal portion) and terminal portion of the right carotid artery. Left carotid angiography showed complete ...

1994-01-01

109

Is intraoperative ultrasound (IOUS) still useful for the detection of liver metastases?  

British Library Electronic Table of Contents (United Kingdom)

SommarioScopo Valutare limpatto clinico negli anni dellecografia intraoperatoria (IOUS) nella identificazione delle metastasi epatiche rispetto alle altre metodiche di imaging. Materiali e metodi risultati delle ecografie intraoperatorie effettuate per lidentificazione delle metastasi epatiche in un periodo compreso tra gli anni 2000 e 2006 sono stati retrospettivamente revisionati e comparati con le metodiche di imaging preoperatorio: Ecografia (US), Tomografia Computerizzata (TC) e/o Risonanza Magnetica (RM). Tutti i casi sono stati patologicamente provati. Sono stati calcolati per anno i casi discordanti in termini di presenza/assenza di lesione focale epatica. Il confronto statistico e stato effettuato con il test di McNemar. Un valore del p<0,05 e stato considerato statisticamente sig...

2009-01-01

110

Ewing's sarcoma. Radiographic pattern of healing and bony complications in patients with long-term survival  

International Nuclear Information System (INIS)

The radiographic appearance of Ewing's sarcoma was studied retrospectively in 22 patients who survived 5 years or longer after diagnosis and treatment. Expected changes from treatment, including regression of the extraosseous soft tissue mass, periostitis, and reconstitution of the cortex, occurred in all patients. Local recurrence occurred in one patient 10 years after complete remission whereas secondary osteosarcoma occurred more than 5 years after complete remission in two other cases. Both recurrent and secondary tumors presented as new lytic foci at the site of the original primary lesion. Lytic changes from radiation (radiation osteitis) may develop more than 2 years after treatment and in this sample; such findings were widely distributed in the radiation port. The authors conclude that bone remodeling and postradiation changes occur slowly over 2 years after treatment, and that any localized lysis at the primary site is suspicious for recurrence or ...

111

Computed Tomography in pulmonary cystic fibrosis  

International Nuclear Information System (INIS)

This study was aimed at evaluating CT sensitivity in identifying the signs of pulmonary cystic fibrosis (CF). The chests of 39 patients (16 males and 23 females, mean age 19.1 years) were examined by CT: all patients had been given a clinical score according to Schwachman and Kulckzycki criteria. Thickened bronchial walls were observed in all cases, which are typical of peribronchitis. Bronchiectases were present in 87% of cases; their extent, pattern and localization were exactly shown on CT scans. Bronchoceles were seen on CT scans in 64% of patients; less frequent was the finding of atelectases and subpleural bullous emphysema. In a great number of patients (64% and 82%, respectively) pleural thickening and hilar adenopathy were demonstrated on CT scans. In conclusion, our results confirm CT as a more sensitive method than conventional radiography to identify and locate the signs of pulmonary CF. The early identification of the lesions of high prognostic value, ...

1991-01-01

112

Magnetic resonanse imaging in otorhinolaryngology. With special reference to the influence of factors upon NMR parameters and differential diagnosis of otorhinolaryngic lesions  

Energy Technology Data Exchange (ETDEWEB)

MRI diagnosis for malignant tumors are made possible by direct comparison to the results obtained by the brain and it seems possible to differentiate malignant tumors from other benign lesions. Cystic lesions, and mycotic sinusitis sometimes resemble malignant tumors in MR Image. In the present report, we investigated the relationships between the biochemical contents of cystic lesions and NMR-parameters to clarify why some inflammatory lesions appeared similar to malignant tumors in MRI. The variation of relaxation time depends upon the amount of protein in the cystic contents and the amount of glucose affects the relaxation time. We conclude that NMR-parameters are useful for the differential diagnosis of malignant tumors, cystic lesions and mycositic sinusitis by using the multiple variation analysis.

1987-07-01

113

Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOVA test. The mean ROC areas of conventional radiography, ...

2003-03-15

114

Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries  

International Nuclear Information System (INIS)

The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOVA test. The mean ROC areas of conventional radiography, ...

2003-03-01

115

Comparison of turbo inversion recovery magnitude (TIRM) with T2-weighted turbo spin-echo and T1-weighted spin-echo MR imaging in the early diagnosis of acute osteomyelitis in children  

Energy Technology Data Exchange (ETDEWEB)

Objective. To compare turbo inversion recovery magnitude (TIRM) with standard T1-weighted (T1-W) and T2-weighted (T2-W) MR sequences in the very early detection of acute osteomyelitis in children. Materials and methods. In 15 children with osteomyelitis, 15 sets of T1-W spin-echo (SE) (TR/TE, 400-640/12-17), T2-W turbo spin-echo (TSE) (TR/TE/ETL, 3290-4465/112-120/11), and TIRM (TR/TE/TI, 4000-6120/60/160) images were acquired with a 1.0-T magnet. Contrast-to-noise (C/N) ratios and percentage of signal between lesion and normal bone marrow were analysed with a computer-assisted image analysing system in a region of interest (ROI). Results. In 13 of 15 patients, the absolute signal enhancement in a ROI on the TIRM images was better than on the T1-W SE and T2-W TSE images and in 14 of 15 cases, C/N ratios were also better on the TIRM images than on the other sequences. In the other cases, the TIRM signal was diagnostically equivalent. On the TIRM ...

1998-11-01

116

Are the delay images necessary to evaIuate the liver metastatic lesions on mangafodipir trisodium enhanced liver MRI?: comparison with hepatocellular carcinomas  

Energy Technology Data Exchange (ETDEWEB)

To assess whether ring enhancements of liver metastases on Mn-DPDP enhanced, early MR images were well visualized on delayed images, as compared with those of hepatocellular carcinomas (HCC), and to investigate the detection accuracy and conspicuity of each tumor. Twenty patients with liver metastases and 15 with HCC were studied by Mn-DPDP enhanced, T1-weighted MR images. Peripheral ring enhancement and conspicuity were investigated. Differences in detection accuracy and frequency of ring enhancement in liver metastases and HCC were assessed. In liver metastases (n= 69), 44 cases (63.8%) without ring enhancement and 25 (36.2%) with were noted on early images. Sixteen cases (23.2%) without ring enhancement, 38 (55.1%) with ring enhancement similar to the early images, and 15 (21.7%) with prominent ring enhancement were noted on delayed images. In HCC (n=37), 36 cases (97.3%) without ring enhancement and 1 case (2.7%) with were noted on early ...

2004-09-01

117

AIDS and lung infection by Mycobacterium xenopi. Role of Computed Tomography; Sindrome da immunodeficienza acquisita e malattie polmonari da Mycobacterium xenopi. Ruolo della Tomografia Computerizzata  

Energy Technology Data Exchange (ETDEWEB)

Mycobacterium xenopi is one of the most common agents responsible for nontubercolar mycobacterial pulmonary disease on AIDS patients. These lesions have been studied with conventional radiography while CT has been used in patients with aspecific mycobacterioses or non-AIDS pulmonary conditions from Mycobacterium xenopi. 12 AIDS patients were examined. They had pulmonary lesions from Mycobacterium xenopi, patients age ranged 30 to 46 years. All patients had CD4 blood levels lower than 250 cells/mL and Mycobacterium xenopi in the sputum. All patients underwent a standard chest radiograph and a CT examination. CT images were evaluated by three radiologists independently and the definitive diagnosis was made in the presence of a fourth radiologist. Chest CT showed parenchymal consolidation in 66% of cases, associated with bilateral basal bands in 16% of cases. Consolidation was unilateral in 41% of cases and most frequently involved the right lower ...

2000-06-01

118

The sensory quality of irradiated breaded poultry products  

International Nuclear Information System (INIS)

The colour, odour, flavour and texture of a breaded turkey escalope irradiated at doses of 2 and 4 kGy was assessed using a trained sensory panel. Irradiation did not affect raw appearance but during storage the irradiated breaded products became paler than the control samples. The off odour of the raw irradiated products was stronger than that of the unirradiated samples. Irradiation also affected the odour, flavour and texture of the cooked products. Although the trained panelists were able to detect significant differences between irradiated and unirradiated breaded turkey escalopes, the numerical differences between treatments were often quite small. It is possible that an untrained consumer group would be unable to detect these differences. Further research is needed with consumer groups to establish if irradiated breaded products are acceptable. (author). 10 refs, 3 tabs.

1994-07-01

119

Suitability of Molecular Markers for Selection of Potatoes Resistant to Globodera spp  

British Library Electronic Table of Contents (United Kingdom)

Globodera rostochiensis and Globodera pallida are parasitic root cyst nematodes of potato (PCN), which significantly reduce yield and quality. The genetics and available molecular markers should make resistance to nematodes an excellent candidate for marker assisted selection. The study presents results of testing the suitability of known molecular markers for detection of resistance in a set of cultivars. We revealed some inconsistencies in genealogical data of the cultivars and showed inconsistent usefulness in detecting resistant cultivars. The marker TG689 was identified in almost all cultivars resistant to G. rostochiensis and together with other markers was used for verifying the resistance in a group of breeding lines. The marker TG689 was the most effective. However, the efficiency...

2011-01-01

120

Microdialysis unit for molecular weight separation  

Energy Technology Data Exchange (ETDEWEB)

The present invention relates generally to an apparatus and method for separating high molecular weight molecules from low molecular weight molecules. More specifically, the invention relates to the use of microdialysis for removal of the salt (low molecular weight molecules) from a nucleotide sample (high molecular weight molecules) for ESI-MS analysis. The dialysis or separation performance of the present invention is improved by (1) increasing dialysis temperature thereby increasing desalting efficiency and improving spectrum quality; (2) adding piperidine and imidazole to the dialysis buffer solution and reducing charge states and further increasing detection sensitivity for DNA; (3) using low concentrations of dialysis buffer and shifting the DNA negative ions to higher charge states, producing a nearly 10-fold increase in detection sensitivity and a slightly decreased desalting efficiency, or (4) any combination of ...

1999-09-21

121

Identification of pork derivatives in food products by species-specific polymerase chain reaction (PCR) for halal verification  

British Library Electronic Table of Contents (United Kingdom)

Pork identification in four types of food products, which are sausages and the casings, bread and biscuits, using species-specific polymerase chain reaction (PCR) detection of a conserved region in the mitochondrial (mt) 12S ribosomal RNA (rRNA) gene was developed. Genomic DNA of the food products were successfully extracted except for the casing samples, where no genomic DNA was detected. The extracted genomic DNA was then subjected to PCR amplification targeting the specific regions of the 12S rRNA gene. The genomic DNA from the food products were found to be of good quality and produced clear PCR products on the amplification of 12S rRNA gene of 387 base pairs (bp) from pork species. The species-specific PCR identification yielded excellent results for identification of pork derivatives...

2007-01-01

122

Eddy current probe development based on a magnetic sensor array; Developpement d'un imageur magnetique pour le controle non destructif par courants de Foucault  

Energy Technology Data Exchange (ETDEWEB)

This research deals with in the study of the use of innovating magnetic sensors in eddy current non destructive inspection. The author reports an analysis survey of magnetic sensor performances. This survey enables the selection of magnetic sensor technologies used in non destructive inspection. He presents the state-of-the-art of eddy current probes exploiting the qualities of innovating magnetic sensors, and describes the methods enabling the use of these magnetic sensors in non destructive testing. Two main applications of innovating magnetic sensors are identified: the detection of very small defects by means of magneto-resistive sensors, and the detection of deep defects by means of giant magneto-impedances. Based on the use of modelling, optimization, signal processing tools, probes are manufactured for these both applications.

2007-06-15

123

An extended CT scale technique for evaluating periprosthetic bone lesions - an in vitro study; Extended-field CT-Technik zur Evaluation von periprothetischen Knochenlaesionen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: In the present study the reduction of artifacts using an extended CT scale technique was examined in 5 vitallium and 5 titanium-aluminium-vanadium tumor prostheses. Methods: 5 titanium-aluminium-vanadium and 5 vitallium distal femur Mutars {sup trademark} tumor prostheses (Mutars {sup trademark} - Modular Universal Tumor And Revision System) were implanted in 10 human femur specimens. 110 artifical drill hole lesions of 1 mm, 2 mm, 3 mm, 5 mm and 8 mm diameter were placed in the bone around the hexagonal stem of the tumor prosthesis and furthermore in the proximal part of the femur. All specimens were examined using conventional CT and an extended CT scale technique in a slice thickness of 3 mm. Results: In the proximal part of the femur all drill holes could be detected using 3 mm slices, no artefacts were observed. Along the hexagonal stem smooth lines arising from each hexagonal plane could be observed. This made it impossible to ...

2001-12-01

124

Robust line width estimation  

Energy Technology Data Exchange (ETDEWEB)

Fabrication of diffused titanium optical guides on a LiNbO/sub 3/ crystal substrate requires precise quality assurance. Light couplers in particular must be positioned within micron specifications. This requirement is the reason that the width of lines detected during microscopic inspection of the crystal is such an important parameter for quality evaluation. To assist in the inspection of these optical guides, a line width estimation program has been developed for an IBM PC based microscope inspection system. A digital image processing approach is used to develop an algorithm which can be tailored by the user for specific signal and noise characteristics. Default filter parameters, which can be updated and saved interactively by the user, are stored in a file on disk. The final program can be executed stand-alone or through a commercially available, menu-driven, image processing software package. Details concerning the ...

1986-07-01

125

Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures  

Energy Technology Data Exchange (ETDEWEB)

AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium ...

2002-04-01

126

Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures  

International Nuclear Information System (INIS)

AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium ...

2002-04-01

127

''SEPIO NUANCE DT'' digital mammography system  

International Nuclear Information System (INIS)

In the past, the need for high quality images, i.e., very sharp and clear images, in mammography have prevented mammography equipment from being digitalized; however, recent advances in detection technology such as development of a high resolution digital X-ray detector have produced improvements in digital mammography. Digital mammography is expected to replace conventional film-screen mammography. We have developed a digital mammography system, named ''SEPIO NUANCE DT'', which is equipped with a direct conversion flat panel detector. The present paper describes the high basic performance and user-friendly functions of the system. (author)

2007-03-01

128

"1H MR spectroscopy in pediatrics  

International Nuclear Information System (INIS)

Spectral appearance and concentrations of the most prominent metabolites are affected by brain development. This knowledge is essential for the detection of pathological changes in pediatric patients. This paper discusses specific conditions of MR spectroscopic examination of children and the effects of age on MR spectra quality and quantitation of the studied metabolites. Clinical examples show several diseases that are reflected in changes in "1H MR spectra due to pathological alterations in the biochemical pathways of the observed metabolites. Attention is given to the main metabolites such as N-acetylaspartate, creatine/phosphocreatine, cholines, lactate, inositol, etc.

2008-08-01

129

Tumour suppressor ING1b maintains genomic stability upon replication stress  

UK PubMed Central (United Kingdom)

The lesion bypass pathway, which is regulated by monoubiquitination of proliferating cell nuclear antigen (PCNA), is essential for resolving replication stalling due to DNA lesions. This process is...Full Text Available

2011-05-01

130

Surgicopathological classification of hepatic space-occupying lesions: A single-center experience with literature review  

UK PubMed Central (United Kingdom)

Accompanying rapid developments in hepatic surgery, the number of surgeries and identifications of histological types of primary hepatic space-occupying lesions (PHSOLs) have increased dramatically....Full Text Available

2011-05-21

131

Regression of atherosclerotic lesions by high density lipoprotein plasma fraction in the cholesterol-fed rabbit.  

UK PubMed Central (United Kingdom)

The effects of homologous plasma HDL and VHDL fractions on established atherosclerotic lesions were studied in cholesterol-fed rabbits. Atherosclerosis was induced by feeding the animals a 0.5% cholesterol-rich...Full Text Available

1990-04-01

132

Optimization of extracranial stereotactic radiation therapy of small lung lesions using accurate dose calculation algorithms  

UK PubMed Central (United Kingdom)

BackgroundThe aim of this study was to compare and to validate different dose calculation algorithms for the use in radiation therapy of small lung lesions and to optimize the treatment...Full Text Available

133

Morules in endometrial carcinoma and benign endometrial lesions differ from squamous differentiation tissue and are not infected with human papillomavirus  

UK PubMed Central (United Kingdom)

Background: Squamous differentiation/squamous metaplasia is often associated with endometrial adenocarcinoma and benign lesions, such as endometrial hyperplasia and chronic endometritis....Full Text Available

2004-09-01

134

Malignant Change in an Epidermal Cyst Over Gluteal Region  

UK PubMed Central (United Kingdom)

A 72-year-old male presented with a large ulceroproliferative lesion over left gluteal region. After histopathological confirmation of squamous cell carcinoma, the lesion was excised with wide margins....Full Text Available

2011-01-01

135

Magnetic resonance imaging in multiple sclerosis. Imagerie nouvelle par resonance magnetique nucleaire au cours de la sclerose en plaques  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) has rapidly attained a major position among the examinations used in the diagnostic approach of multiple sclerosis because it is highly sensitive in demonstrating lesions. However, these lesional images may have several meanings, and there is the problem of distinguishing between oedema, which is said to reflect recent lesions, and gliosis which is thought to betray old lesions. The intrinsic MRI parameters studied (i.e. relaxation times) are unable to make this distinction, whereas it is provided by paramagnetic contrast media such as gadolinium. There is no correlation between the changes observed at MRI and the severity of the disease. Another problem is the accuracy of lesion localization, since visualization is predominantly macroscopic. This raises several questions about the demonstration of correlations between clinical signs and site of the ...

1991-09-15

136

MRI in definition of bleeding source, lesion pattern and therapy in haemarthros of the knee  

International Nuclear Information System (INIS)

Patients with haemarthros of the knee were examined by MRI and arthroscopy to identify the bleeding source and to determine surgical or conservative therapy. A prospective study was performed on 120 patients who underwent MRI and arthroscopy, point lesions and bleeding sources were documented separately on a standardised form. Arthroscopy demonstrated a ruptured anterior cruciate ligament in 86%, meniscal tears in 55%, disruption of collateral ligaments in 17%, osteochondral lesions in 5% and tears of capsule or plicae in 13%. Disruption of cruciate ligaments caused haemorrhage in all but three cases. In contrast, only meniscal tears located very adjacent to the meniscal basement had bled. Those types of osteochondral lesions caused haemorrhage characterised on MRI by destruction of the subchondral plate and overlying cartilage. Severe lesions of the knee were diagnosed by MRI in 71% to 100%, slight ...

137

Imaging Findings of Localized Lymphoid Hyperplasia of the Pancreas: a Case Report  

UK PubMed Central (United Kingdom)

We report here on a case of localized lymphoid hyperplasia of the pancreas in a 70-year-old man which manifested as double lesions (uncinate process and tail) in the organ. The lesions were incidentally...Full Text Available

2011-07-01

138

IL-6-Dependent Mucosal Protection Prevents Establishment of a Microbial Niche for Attaching/Effacing Lesion-Forming Enteric Bacterial Pathogens1  

UK PubMed Central (United Kingdom)

Enteric infections with attaching/effacing lesion-inducing bacterial pathogens are a worldwide health problem. A murine infection model with one such pathogen, Citrobacter rodentium,...Full Text Available

2008-05-15

139

Diagnosis and Management of Cystic Lesions of the Pancreas  

UK PubMed Central (United Kingdom)

Pancreatic cysts are challenging lesions to diagnose and to treat. Determining which of the five most common diagnoses—pancreatic pseudocyst, serous cystic neoplasm (SCN), solid pseudopapillary...Full Text Available

2011-01-01

140

Characterization of Two Unique Cholesterol-Rich Lipid Particles Isolated from Human Atherosclerotic Lesions  

UK PubMed Central (United Kingdom)

The authors' laboratory, using histochemicalmethods, previously identified two types of cholesterol-containing lipid particles in the extracellular spaces of human atherosclerotic lesions, one particle...Full Text Available

1990-01-01

141

CT-guided percutaneous core biopsies of pulmonary lesions: Diagnostic accuracy, complications and therapeutic impact  

International Nuclear Information System (INIS)

To evaluate the diagnostic accuracy, complications, and therapeutic impact of CT-guided percutaneous core biopsies of pulmonary lesions. Material and methods: Seventy-nine patients underwent diagnostic CT-guided percutaneous core biopsies of pulmonary lesions between July 1995 and March 1999. Evaluation included corresponding clinical data, pathologic results, and therapeutic consequences. Results: There were 29 benign and 50 malignant lesions. Percutaneous core biopsy had an overall diagnostic accuracy of 95%. For malignant lesions, core biopsy was positive in 48 patients (sensitivity 96%), and for benign lesions, in 27 (sensitivity 93%). There were no false-positive findings. Pneumothoraces were observed in 19 patients (24%) and 4 of them required a chest drain (5%). There were no hematothoraces or major bleeding complications; however, postinterventional local hemorrhages were ...

2001-03-01

142

Bacterial infections in suspected cutaneous leishmaniasis lesions.  

UK PubMed Central (United Kingdom)

In Iran, microscopic examination of skin scrapings from 2202 individuals with clinically diagnosed cutaneous leishmaniasis (CL) lesions revealed the presence of amastigotes in 1123 cases (51.0%). Bacteriological...Full Text Available

1990-01-01

143

Association of Unique, Isolated Treponemes with Bovine Digital Dermatitis Lesions?  

UK PubMed Central (United Kingdom)

This study used a PCR-based approach targeting 16S rRNA gene fragments to determine the occurrence and association of the three bovine digital dermatitis (BDD) treponeme phylogroups within lesions found...Full Text Available

2009-03-01

144

The magnetic resonance and its agro-industry applications; a review  

International Nuclear Information System (INIS)

The electromagnetic properties that present hydrogen and other nucleus of agro-alimentary products, have allowed widely use of magnetic resonance (MR) to study the composition and internal structure of these biological materials in a micro and macroscopic scale, in a nondestructive way. In this paper the physical principles, basic equipment to measure the MR signals and the MR imaging of any biological sample, are explained. It is also shown a review of the main agro-alimentary applications, emphasizing in the use of this principle to examine the internal quality of fruits and vegetables. In these products, the MR has been used to detect and follow the evolution of different factors that determine the internal quality after harvesting, during storage and after post harvesting processes. The main studies that have been conducted with MR in harvested products are about physiological disorders that take place during storage ...

145

Radiotherapy quality insurance by individualized in vivo dosimetry: state of the art; Dosimetrie individuelle in vivo pour le controle de qualite en radiotherapie: etat de l'art  

Energy Technology Data Exchange (ETDEWEB)

The quality insurance in radiotherapy in the frame of highly complex technical process as Intensity modulated radiotherapy (I.M.R.T.) needs independent control of the delivered dose to the patient. Actually, up to now, most of the radiotherapy treatments rely only on computed dosimetry through a rather complicated series of linked simulation tool. This dosimetry approach requires also qualified treatment means based on cautious quality insurance procedures. However, erroneous parameters could be difficult to detect and systematical errors could happen leading to radiotherapy accidents. In this context, in vivo dosimetry has a critical role of final control of the delivered dose. As many beam incidences and ports are used for any photon therapy treatment, external control could be very tedious and time consuming. Therefore, innovations are needed for in vivo dosimetry to provide ergonomic and efficient tools for these ...

2009-06-15

146

Indoor air quality and thermal comfort studies of an under-floor air-conditioning system in the tropics  

Energy Technology Data Exchange (ETDEWEB)

This paper reports thermal comfort and indoor air quality (IAQ) studies of an under-floor air-conditioning (UFAC) system in a hot and humid climate. Thermal comfort parameters were measured at pre-determined grid points within an imaginary plane to predict the air flow pattern of the supply air jet as well as to determine the occurrence of thermal stratification in the office space. Fanger's thermal comfort index was also computed to detect the occupants' thermal sensation. Besides, the concentration levels of dust and carbon dioxide were recorded with the intention to examine the quality of the indoor air. Statistical methods were applied to derive the relationship between air velocity and the other parameters as mentioned earlier. The main findings from the study revealed reasonable level of acceptability of IAQ associated with the UFAC system. However, occupants are likely to experience localised ...

2002-07-01

148

Lesion of the esophagus by tetracycline medication  

Energy Technology Data Exchange (ETDEWEB)

One case of esophagitis caused by oral medication of Tetracycline is reported. The cause and factors predisposing to this uncommon complication of oral medication are discussed.

1984-06-01

149

Magnetic resonance appearance of fibromatosis  

International Nuclear Information System (INIS)

We reviewed retrospectively the magnetic resonance (MR) images of 14 soft-tissue lesions of fibromatosis (desmoid tumors) encountered in 11 patients. The lesions were typically inhomogeneous in texture and round to oval in configuration. Margins were well-defined in 78% of the lesions at presentation and were infiltrating in all recurrences. (orig./DG).

150

Differential diagnosis of tumorous lesions in the iliac bone in children  

Energy Technology Data Exchange (ETDEWEB)

The radiologic appearance of inflammatory and tumorous lesions in the iliac bone is characterized by destructive alterations and consolidations simultaneously. This pattern is nonspecific. The value of plain films of this area is compromised by the anatomy of the iliac bone and by overlying structures. Therefore tomography, computer tomography and bone scans are necessary. Difficulties in differentiation between benign and malignant lesions are discussed and case reports are given. The importance of histologic examination is stressed.

1984-02-01

151

Cystic lesions of the seminal vesicles. Demonstration by MRI. Zystische Raumforderungen der Samenblasen. Darstellung mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Between October 1990 and March 1991, 8 patients with cystic lesions in the region of the posterior bladder wall, the seminal vesicles and the prostate were examined by MRI. In all cases there was accurate characterisation of the lesion and of its anatomy. In 3 patients with abnormalities in the retrovesical space there was very good agreement with the operative findings. 4 patients were treated conservatively. In these patients there was good agreement with the findings on cystoscopy, CT and sonography. (orig.).

1992-07-01

152

Computed radiography. Evaluation of its role in the mass survey for lung cancer: Phantom study  

Energy Technology Data Exchange (ETDEWEB)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in the retrocardiac and subdiaphragmatic regions, respectively. ...

1987-12-01

153

Computed radiography  

International Nuclear Information System (INIS)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in the retrocardiac and subdiaphragmatic regions, respectively. ...

1987-01-01

154

Application of the microbiological method DEFT/APC to detect minimally processed vegetables treated with gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

Marketing of minimally processed vegetables (MPV) are gaining impetus due to its convenience, freshness and apparent health effect. However, minimal processing does not reduce pathogenic microorganisms to safe levels. Food irradiation is used to extend the shelf life and to inactivate food-borne pathogens. In combination with minimal processing it could improve safety and quality of MPV. A microbiological screening method based on the use of direct epifluorescent filter technique (DEFT) and aerobic plate count (APC) has been established for the detection of irradiated foodstuffs. The aim of this study was to evaluate the applicability of this technique in detecting MPV irradiation. Samples from retail markets were irradiated with 0.5 and 1.0 kGy using a {sup 60}Co facility. In general, with a dose increment, DEFT counts remained similar independent of the irradiation while APC counts decreased gradually. The difference of ...

2009-07-15

155

Particle Detection with drift Chambers  

CERN Document Server

Particle Detection with drift Chambers

2008-01-01

156

Sensors and instrumentation for atmospheric pollutions control; Capteurs et instrumentation pour le controle des pollutions atmospheriques  

Energy Technology Data Exchange (ETDEWEB)

Reinforcement of the legislation concerning the emission of atmospheric pollutants, aerosols, refrigerants, solvents etc and the reduction of the greenhouse effect, has led to the development of performing instruments for the survey and control of ambient air quality and for the limitation of exhaust gases, combustion products, volatile organic compounds (VOC), particulates and noxious compounds in the atmosphere. This study is divided in 4 main parts. The first part describes the context of the air quality control: the problems linked with the environment and health, the pollutants characteristics, the pollution levels and the detection sensitivity of instruments according to the different type of pollutants (petroleum products, VOCs, ozone compounds, particulates, smells..), the protocols of air pollution measurements and their application (chimney smokes, industrial volatile compounds, indoor and ambient air ...

1996-11-01

157

Implant detectibility of intervertebral disc spacers in post fusion MRI: evaluation of the MRI scan quality by using a scoring system - an in vitro study  

International Nuclear Information System (INIS)

Intervertebral spacers for anterior spine fusion are made of different materials, such as titanium and cobalt chromium alloys and carbon fiber-reinforced polymers. Implant-related susceptibility artifacts can decrease the quality of MRI scans. The aim of this cadaveric study was to demonstrate the extent that implant-related MRI artifacting affects the postfusion differentiation of determined regions of interest (ROIs). In six cadaveric porcine spines, we evaluated the postimplantation MRI scans of a titanium, cobalt-chromium and carbon spacer that differed in shape and surface qualities. A spacer made of human cortical bone was used as a control. A defined evaluation unit was divided into ROIs to characterize the spinal canal as well as the intervertebral disc space. Considering 15 different MRI sequences read independently by an interobserver-validated team of specialists the artifact-affected image quality of the median ...

2007-02-01

158

Usefulness of "1"8F-FDG PET in intrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Surgical resection is the only curative treatment strategy for intrahepatic cholangiocarcinoma (CC). Therefore, accurate staging is essential for appropriate management of patients with CC. We assessed the usefulness of 2-["1"8F]fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) in the staging of CC. We undertook a retrospective review of FDG PET images in 21 patients (10 female, 11 male; mean age 57 years) diagnosed with CC. Ten patients had hilar CC and 11, peripheral CC. Patients underwent abdominal magnetic resonance imaging (MRI) (n=20) and computed tomography (CT) (n=12) for the evaluation of primary tumours, and chest radiography and whole-body bone scintigraphy for work-up of distant metastases. For semi-quantitative analysis, the maximum voxel standardised uptake value (SUV_m_a_x) was obtained from the primary tumour. All peripheral CCs showed intensely increased FDG uptake, and some demonstrated ring-shaped uptake corresponding to peripheral rim enhancement on ...

2003-11-01

159

Occurrence of mutations in the epidermal growth factor receptor gene in X-ray-induced rat lung tumors  

International Nuclear Information System (INIS)

Epidermal growth factor receptor (EGFR) gene alterations have been found in human lung cancers. However, there is no information on the factors inducing EGFR mutations. In rodents, K-ras mutations are frequently found in many lung carcinogenesis models, but hitherto, Egfr mutations have not been reported. Their presence was therefore investigated in representative lung carcinogenesis models with 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), N-nitrosobis(2-hydroxypropyl)amine (BHP), 2-amino-3,8-dimethylimidazo[4,5-f]quinoxaline (MelQx) and ethyl carbamate (urethane), as well as X-ray irradiation. With the chemical carcinogenesis models, no mutations were detected in Egfr, which is in clear contrast to the high rates observed in either codon 12 or 61 of K-ras (21/23 of the lung tumors induced with NNK, 4/5 with MelQx, 1/4 with urethane and 7/18 with BHP). However, in the X-ray-induced lung tumors, Egfr mutations with amino acid substitution were observed in ...

2008-02-01

160

Laser flash effects on chromatic discrimination in monkeys. Final report, April 1986-June 1987  

Energy Technology Data Exchange (ETDEWEB)

Detecting a camouflaged target in a visually noisy background depends on the ability of the observer to discriminate the target from the surrounding terrain. Visible laser irradiation at less than damage levels can act as a masking source by compromising or reducing the observer's ability to resolve differences in the visual scene. Previous research has examined this concept by investigating laser flash effects on: acuity (size discrimination); tracking (motion discrimination); visual sensitivity (color); and contrast sensitivity functions (luminance contrast). In all cases, flashes from continuous-wave (CW) sources have proven more effective visually than pulsed (Q-switched) sources, when compared on peak-energy criteria (i.e., MPE), even though Q-switched lasers induce damage at lower energy doses. Additionally, the inherent safety of ultra-short laser pulses has been questioned. Past animal research has shown that, on the measures of acuity, ...

1987-10-01

161

Local control of Ewing's sarcoma of bone with radiotherapy and combination chemotherapy  

International Nuclear Information System (INIS)

Between 1964 and 1977, 94 patients with Ewing's sarcoma of bone were treated at the National Cancer Institute. They received 5000 rad to the whole bone and progressively more aggressive chemotherapy protocols. The patients were divided according to site of primary lesion into central, proximal and distal lesions, with 19%, 33% and 57%, respectively, alive and well. The local control rate is high (93%), with good functional results in the distal lesions, and no changes are needed in radiation therapy dose or volume. Control is not as satisfactory for central and proximal lesions and efforts need to be made to increase control at these sites. We are at present attempting to define more accurately the extent of soft tissue disease, increasing the dose to 6000 rad for central lesions, and using a more aggressive chemotherapy program, in the hope of increasing the local control in these ...

162

Benign lymphoepithelial lesion of the parotid gland in AIDS patients: CT characteristics  

International Nuclear Information System (INIS)

Contrast agent-enhanced CT scans in nine male patients with histologically proved benign lymphoepithelial lesions of the perotid gland were reviewed. All scans showed cystic-appearing masses with peripheral rim enhancement corresponding to the macroscopic appearance of the lesion. Five patients were seropositive for human immunodeficiency virus (HIV) infection or had infections seen in acquired immunodeficiency syndrome. Three patients were members of high-risk groups. Only one patient had symptoms of the SICCA syndrome. Once a rare cause of parotid gland enlargement, benign lymphoepithelial lesions have recently been seen with increasing frequency in patients with HIV infection. Although the CT appearance is not pathognomic, correlation results of aspiration cytology and with clinical history can lead to a preoperative diagnosis of a benign lymphoepithelial lesion.

163

Magnetic resonance imaging in the evaluation of pneumonia; Nachweis von pneumonischen Infiltraten mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) of the lung is challenging because of substantial drawbacks. However, lung pathologies that are associated with increased attenuation values in CT enhance visualization in MRI: proton density is increased and tissue-air interfaces, resulting in susceptibility artifacts, are reduced in pneumonia, pneumonitis, edema, and carcinoma. On the other hand, many lung diseases result in shortness of breath, so that patients cannot hold their breath for long periods. Therefore, fast imaging techniques are required which should also allow for high spatial resolution so that small lesions can be detected. Calcifications and air pockets within lesions are not readily recognized with MRI. Thin section CT is standard for the diagnosis of pneumonia. With parallel imaging techniques, MRI examination of the lungs can be performed with short periods of breath holding, which allow for sub-centimeter resolution ...

2006-04-15

164

Magnetic resonance appearance of peripheral nerve sheath tumors  

International Nuclear Information System (INIS)

Magnetic resonance imaging (MRI) was used to evaluate 22 histological proven peripheral nerve sheath tumors, approximately two-thirds of which arose in the lower extremity. The histologic distribution was as follows: 12 schwannomas, 7 neurofibromas, and 3 malignant peripheral nerve sheath tumors (2 of which occurred in patients with neurofibromatosis). Most lesions demonstrated an intermediate to moderately bright signal on T_1-weighted images and were minimally inhomogeneous. All lesions were moderately bright on T_2-weighted images, again with variable inhomogeneity. The extent of the tumor was best assessed on proton-density- and T_2-weighted images. Smooth margins were noted in 19 lesions. Of the 3 remaining lesions, 2 were malignant (but had been subjected to biopsy prior to MRI), and the other lesion was a plexiform neurofibroma. MRI accurately determined the relationship ...

165

Marketers report on oil quality  

Energy Technology Data Exchange (ETDEWEB)

The quality of fuel oils is discussed. The problems that the fuel oil marketer must deal with that relate to the quality of the fuel oil are described.

1985-04-01

167

Process-integrated online monitoring of safety-relevant aluminum airbag pressure vessel components for a combined defect detection and material property determination by using contactless NDT (EMUS and EC)  

Energy Technology Data Exchange (ETDEWEB)

Airbag pressure vessels for the north-American market mainly are made by forging and by the use of steel alloys. In Europe aluminum alloys are common and the manufacturing process is extrusion of circular blanks - made from cold rolled plates - in a form applying a 100 t press at room temperature. Then by heat treatment the strength/hardness of the material is properly adjusted and after that the pressure vessel parts have to be continuously inspected with an inspection and handling cycle time of 3 s. Inspection of the axis-symmetric parts is asked for surface breaking extrusion defects as well as for surface parallel delaminations in the bulk volume. Furthermore, the material strength is a quality characteristic that has to be nondestructively registered and documented. The inspection is performed by eddy current probes and an EMAT, of which the eddy current impedance measurements are used for surface breaking extrusion defect detection and ...

1999-07-01

168

Phase- and size-adjusted CT cut-off for differentiating neoplastic lesions from normal colon in contrast-enhanced CT colonography  

Energy Technology Data Exchange (ETDEWEB)

A computed tomography (CT) cut-off for differentiating neoplastic lesions (polyps/carcinoma) from normal colon in contrast-enhanced CT colonography (CTC) relating to the contrast phase and lesion size is determined. CT values of 64 colonic lesions (27 polyps <10 mm, 13 polyps {>=}10 mm, 24 carcinomas) were determined by region-of-interest (ROI) measurements in 38 patients who underwent contrast-enhanced CTC. In addition, the height (H) of the colonic lesions was measured in CT. CT values were also measured in the aorta (A), superior mesenteric vein (V) and colonic wall. The contrast phase was defined by xA + (1 - x)V using x as a weighting factor for describing the different contrast phases ranging from the pure arterial phase (x=1) over the intermediate phases (x=0.9-0.1) to the pure venous phase (x=0). The CT values of the lesions were correlated with their height ...

2004-12-01

169

Rational protection of the quality of coastal waters by means of integrated, real-time management of the water environment; Proteccion racional de la calidad de las aguas costeras mediante la gestion integrada y en tiempo real del medio hidrico  

Energy Technology Data Exchange (ETDEWEB)

Before the implementation Water Framework directive, it was usual to forget that a good environment protection of the receiving waters needs a correct and coordinated operation of the subsystems of the water cycle, specially sewerage system, WWTP and receiving waters. This explains that most of the countries have focused their efforts in the treatment of dry weather flows forgetting the management of wet weather flows. Actually the idea that a sewerage system or a WWTP can not be planned or managed independently without considering the effects on the receiving waters is commonly accepted because not only each one of these systems must work correctly but also it is required a minimum impact in the receiving waters of the sewerage and WWTP overflows in dry and wet weather. All these links will affect the management strategy of the sewerage system (storm water detection tanks, gates, pumping stations, etc)., the interceptor, the WWTP and the receiving waters. Only an ...

2005-07-01

170

Focused ion beam etching of nanometer-size GaN/AlGaN device structures and their optical characterization by micro-photoluminescence/Raman mapping  

Energy Technology Data Exchange (ETDEWEB)

The authors report on the nano-fabrication of GaN/AlGaN device structures using focused ion beam (FIB) etching, illustrated on a GaN/AlGaN heterostructure field effect transistor (HFET). Pillars as small as 20nm to 300nm in diameter were fabricated from the GaN/AlGaN HFET. Micro-photoluminescence and UV micro-Raman maps were recorded from the FIB-etched pattern to assess its material quality. Photoluminescence was detected from 300nm-size GaN/AlGaN HFET pillars, i.e., from the AlGaN as well as the GaN layers in the device structure, despite the induced etch damage. Properties of the GaN and the AlGaN layers in the FIB-etched areas were mapped using UV Micro-Raman spectroscopy. Damage introduced by FIB-etching was assessed. The fabricated nanometer-size GaN/AlGaN structures were found to be of good quality. The results demonstrate the potential of FIB-etching for the nano-fabrication of III-V nitride devices.

2000-07-01

171

Advanced nanoscale separations and mass spectrometry for sensitive high-throughput proteomics  

Energy Technology Data Exchange (ETDEWEB)

We review recent development in separations and mass spectrometric instrumentation for sensitive and high-throughput proteomic analyses. These efforts have been primarily focused on the development of high-efficiency (separation peak capacity of ~103) nanoscale liquid chromatography (nanoLC; e.g., flow rates extending down to ~20 nL/min at optimal separation linear velocities through narrow packed capillaries) in combination with advanced mass spectrometry (MS), including high sensitivity and high resolution Fourier transform ion cyclotron resonance (FTICR) MS. This technology enables MS analysis of low nanogram-level proteomic samples (i.e., nanoscale proteomics) with individual protein identification sensitivity at the low zeptomole-level. The resultant protein measurement dynamic range can reach 106 for nanogram-sized proteomic samples, while more abundant proteins can be detected from complex sub-picogram size proteome samples. The average proteome ...

2005-06-01

172

Aggressive Ewing's sarcoma appearing as a cold lesion on bone scan  

International Nuclear Information System (INIS)

Ewing's sarcoma classically presents as a hot spot on bone scan as a result of increased vascularity of the tumor and new bone formation. Purpose We report and analyze an uncommon pattern of a 'cold' lesion in Ewing's sarcoma on bone scan and its pathophysiologic significance. Case report A 15-year-old boy complaining of thigh pain. CT scan evoked Ewing's sarcoma or osteitis. MRI evoked chronic osteitis. Scintigraphy showed a fairly intense and heterogeneous uptake on the femoral lesion and no abnormal uptake elsewhere. Biopsy showed none pathologic pattern. Three months later, a second biopsy concluded to Ewing's sarcoma. Bone scan showed a larger lesion with peripheral intense uptake centered by enlarged 'cold' area in the left femoral diaphysis and no evident bone metastasis. The patient underwent chemotherapy and surgery. Three months later, bone scan showed extensive skeletal metastasis. Conclusion Ewing's sarcoma ...

2009-10-01

173

The LSST Data Mining Research Agenda  

CERN Document Server

We describe features of the LSST science database that are amenable to scientific data mining, object classification, outlier identification, anomaly detection, image quality assurance, and survey science validation. The data mining research agenda includes: scalability (at petabytes scales) of existing machine learning and data mining algorithms; development of grid-enabled parallel data mining algorithms; designing a robust system for brokering classifications from the LSST event pipeline (which may produce 10,000 or more event alerts per night); multi-resolution methods for exploration of petascale databases; indexing of multi-attribute multi-dimensional astronomical databases (beyond spatial indexing) for rapid querying of petabyte databases; and more.

2008-01-01

174

Removal of scattered thermal neutrons using antiscatter grid  

International Nuclear Information System (INIS)

One of the significant factors of neutron radiographic image degradation is scattering blur from the object. A practical method is described to enhance image quality by eliminating the overlapping of scattered thermal neutrons component from the objects in ETRR-2 neutron radiography facility, using aluminum Gd-coated antiscatter grid. The MCNP code was used to determine the optimum grid dimensions that will reduce the scattered thermal neutrons from the object. An experiment was performed to determine the optimum grid height and irradiation time that gives the best image with acceptable geometric unsharpness. Using the MCNP code it was found that 97% of the scattered neutrons were removed by the grid. The wall dimensions and Gd coating are so small that the facility resolution cannot detect the image pattern superposition on the film.

2006-12-01

175

Phthalate monoesters in perfusate from a dual placenta perfusion system, the placenta tissue and umbilical cord blood  

British Library Electronic Table of Contents (United Kingdom)

Fetal exposure to phthalates may be associated with adverse reproductive effects, including cryptorchidism and decreased semen quality. Information about human placental transfer is needed to qualify the hypotheses. A dual recirculating placenta perfusion system to monitor concentrations of eight phthalate monoesters in fetal and maternal perfusates was established. In addition to perfusate background measures of phthalate monoesters, the concentrations in umbilical cord plasma and placenta tissue were measured. Monomethyl phthalate (mMP), monoethyl phthalate (mEP), monobutyl phthalate (mBP), and mono (2-ethyl-hexyl) phthalate (mEHP) were detected in both maternal and fetal perfusate, demonstrating a release of compounds from tissue or blood to perfusates. The distribution of compounds bet...

2007-01-01

176

P03-378 - Erectile dysfunction in psychiatric patients  

British Library Electronic Table of Contents (United Kingdom)

Introduction: Erectile dysfunction (ED) is defined as the inability to achieve or maintain an erection sufficient for sexual activity. Objectives: ED is a common condition in psychiatric patients, which can modify their quality of life. Aims: The aim of this study is to assess the prevalence and the severity of ED in psychiatric patients. Methods: This naturalistic, observational study was conducted during a six months period. The International Index of Erectile Function (IIEF) 15-item questionnaire was used to assess 144 male inpatients with different psychiatric disorders. IIEF is a brief, cross-culturally valid, self-administered scale for detecting treatment-related changes in patients with erectile dysfunction and addresses the relevant domains of male sexual function: erectile functi...

2011-01-01

177

Neutron-induced fission cross-section of {sup 233}U in the energy range 0.5<E{sub n}< 20 MeV  

Energy Technology Data Exchange (ETDEWEB)

The neutron-induced fission cross-section of {sup 233}U has been measured at the CERN n-TOF facility relative to the standard fission cross-section of {sup 235}U between 0.5 and 20MeV. The experiment was performed with a fast ionization chamber for the detection of the fission fragments and to discriminate against {alpha} -particles from the natural radioactivity of the samples. The high instantaneous flux and the low background of the n-TOF facility result in data with uncertainties of {approx} 3%, which were found in good agreement with previous experiments. The high quality of the present results allows to improve the evaluation of the {sup 233}U (n,f) cross-section and, consequently, the design of energy systems based on the Th/U cycle. (orig.)

2011-01-15

178

Environmental Kuznets curve for CO2 in Canada  

British Library Electronic Table of Contents (United Kingdom)

According to the environmental Kuznets curve hypothesis, the relationship between per-capita GDP and per-capita pollutant emissions has an inverted-U shape. This implies that, past a certain point, economic growth may actually be profitable for environmental quality. Most studies on this subject are based on estimating fully parametric quadratic or cubic regression models. While this is not technically wrong, such an approach somewhat lacks flexibility since it may fail to detect the true shape of the relationship if it happens not to be of the specified form. We use semiparametric and flexible nonlinear parametric modeling methods in an attempt to provide more robust inferences. We find little evidence in favour of the environmental Kuznets curve hypothesis. Our main results could be inte...

2010-01-01

179

Development of the high sensitivity real-time neutron radiography for low-flux neutron sources  

Energy Technology Data Exchange (ETDEWEB)

The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose of developing a system with higher sensitivity, consideration of neutron statistics ...

1994-08-01

180

Development of the high sensitivity real-time neutron radiography for low-flux neutron sources  

International Nuclear Information System (INIS)

The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose of developing a system with higher sensitivity, consideration of neutron statistics ...

1994-01-01

181

Air conditioning in high rise buildings; conditionnement d'air dans les immeubles de grande hauteur  

Energy Technology Data Exchange (ETDEWEB)

This book brings together the 103 presentations given at the 2. conference of the international institute of refrigeration (IIF/IIR) about air conditioning in high rise office buildings. The main themes are: design of air conditioning equipment for high buildings; air quality and thermal comfort inside these buildings; constraints and possible improvements of the refrigeration equipment used; energy conservation; fire protection and smokes detection. All themes are presented both on the technical and economical points of view and concern more particularly the buildings of Chinese cities. This publication is available both on the book and CD-Rom forms. (J.S.)

2000-07-01

182

A study of reconstruction algorithms and filters for an industrial X-ray tomography system  

Energy Technology Data Exchange (ETDEWEB)

Computed tomography (CT) has been incorporated in an industrial Diode-Array Digital Radiography (DADR) system. An input data size of 512 pixel points x 400 projections yielded a 400x400 output image matrix. Reconstruction algorithms used are the filtered backprojection (FBP) and the direct Fourier reconstruction (DFR). Various filters were used in the FBP reconstruction process and their effects on image quality were evaluated. A spatial resolution of 100 {mu}m was measured with a block of plates and a minimum detectable feature size in the range of 10-100 {mu}m was measured using thin wires. Industrial specimens imaged have included ceramic samples, ball bearings and integrated circuits. A number of engineering problems have been solved, such as adjustment of the X-ray source, centering of the rotator spindle in the view field and beam-hardening corrections. (orig.).

1990-12-20

183

Non-destructive testing of refractories, especially AZS materials, with ultrasound, microwaves and {gamma}-radiation  

Energy Technology Data Exchange (ETDEWEB)

In principle four different methods (ultrasound, microwaves, {gamma}-radiation and x-rays) are available for the non-destructive testing of refractories. Three of these methods, i.e. ultrasound, microwaves and {gamma}-radiation, are in use by different producers of AZS materials to carry out the quality control of their products. This paper will compare the three methods on the basis of the physical properties, present the existing devices, and show the advantages as well as the limits of the different methods. {gamma}-radiography, the oldest method in use, has one main disadvantage, which is the requirement of protection against radioactive radiation. Furthermore, while cracks and cavities can be detected with this method, structural changes can not be monitored. Therefore, the ultrasonic method was developed that allows to detect variations of porosity and grain size as well as cracks and voids when the ultrasonic ...

1995-08-01

184

MRI in preoperative evaluation of chronic paranasal sinusitis - a comparison with CT  

International Nuclear Information System (INIS)

Purpose: To determine the value of MRI in the preoperative evaluation of chronic paranasal sinusitis and to compare the results with CT and intraoperative findings. Method/Materials: 42 patients with clinical signs of chronic paranasal sinusitis underwent MRI after CT evaluation on one day, with subsequent functional endoscopic sinus surgery on the next day. Coronary CT was obtained with 5-mm slices and table-feed in the prone position, while MRI was performed in the supine position with coronary T_2-TSE+pd and coronary and transverse HASTE, each with 5-mm slice thickness. Aquisition time in MRI was less than 8 minutes. Two radiologists reviewed the CT and MRI scans for signs of sinusitis and detection of anatomical landmarks. The results were correlated with the intraoperative findings. Results: MRI offered no artifacts of dental work and showed more often high quality pictures than CT. CT and MRI demonstrated a good correlation in the ...

2001-04-01

185

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two detectors, respectively and the imaging quality of phantoms. ...

2007-01-01

186

Case report 437: Solitary (unicameral, simple) bone cyst of the scapula  

Energy Technology Data Exchange (ETDEWEB)

A case has been presented of an expanding, aggressive bone cyst in the scapula of an 11-year-old girl. The lesion had the appearance of a highly aggressive, cyst-like disorder that appeared to be benign. Biopsy and histological preparation confirmed the presence of a solitary bone cyst. The clinical, radiological, and pathological criteria associated with a solitary bone cyst, particularly in the scapula, were discussed and the literature was reviewed. The differential diagnosis was stressed and a number of examples of scapular lesions was presented radiologically, particularly lesions that might be confused with solitary bone cyst. (orig./SHA).

1987-08-01

187

Vascular Effects of Photodynamic and Pulsed Dye Laser Therapy Protocols  

UK PubMed Central (United Kingdom)

Background and ObjectivePulsed dye laser (PDL) treatment of cutaneous vascular lesions is associated with variable and unpredictable efficacy. Thus, alternative treatment...Full Text Available

2008-11-01

188

The ultrastructure of conjunctival melanocytic tumors.  

UK PubMed Central (United Kingdom)

The ultrastructure of conjunctival melanocytic lesions in 49 patients was evaluated to find significant differences between benign and malignant cells. The patients studied included 9 with benign epithelial...Full Text Available

1984-01-01

189

Tarlov Cyst and Infertility  

UK PubMed Central (United Kingdom)

Background/Objective:Tarlov cysts or spinal perineurial cysts are uncommon lesions. These are mostly incidental findings on magnetic resonance imaging or myelograms. The...Full Text Available

2009-04-01

190

Sacral haemangioma as a cause of coccydynia  

International Nuclear Information System (INIS)

We report a 55-year-old woman with coccydynia due to a sacral mass. The histological diagnosis was haemangioma. The MRI findings and the unusual location of this lesion are discussed. (orig.)

1998-08-01

191

Primary study on lesion mimic mutants of rice (oryza sativa L.)  

International Nuclear Information System (INIS)

Nineteen lesion mimic mutants (xsl1-19) of japonica rice Xiushui11 were obtained by ?-rays irradiation treatment. All mutants belonged to whole life lesion mimic. Lesion mimic of mutants didn't largen after tillering stage, leaves didn't wither, and no effect on the plants exsert spikes and seed. When the highest temperature in day exceeded 32 degree C in seedling stage, lesion mimic of all mutant expect xsl19 disappeared. Under 32 degree C, lesion mimic would appear gradually, and symptoms weren't inhibited by high temperature after 5 leaf stage. The plant heights of all lesion mimic mutants were 47.56-63.54 cm in the tillering stage, and that of CK was 83.75 cm; but the dwarf phenomenon of mutants only appeared before tillering stage, and didn't affect plant heights finally; the heading dates of mutants were the same to the CK, the ear length of all mutants ...

2007-08-01

192

Plain radiographic predictors of survival in treated Ewing's sarcoma  

International Nuclear Information System (INIS)

We analyzed 16 radiographic features of primary Ewing's sarcoma in 342 patients from the IESS 7299 (Intergroup Ewing's Sarcoma Study) for prognostic significance. Of these, 3 features demonstrated a statistically significant relationship to survival: maximal tumor dimension, tumor location, and an appearance of honeycombing within the lesion. Those individuals with primary lesions centered in the pelvis, femur, or humerus had a worse survival rate than those with lesions centered elsewhere. Similarly, we observed an inverse relationship between the greatest dimension of the osseous portion of the lesion and survival. The radiographic finding of honeycombing also showed a statistical association with improved survival. However, this feature was observed infrequently, and its significance should be assessed further. Otherwise, no other feature that we analyzed showed any relationship to patient prognosis. ...

193

Neural Tissues from the Implanted Stem Cells  

International Science & Technology Center (ISTC)

Morphological, Electrophysiological and Behavioral Investigations of the Nervous Tissue Developed from the Embryonic Matrix Zone Cells of the Dorsolateral Walls of Lateral Ventricles, Implanted into the Lesioned Regions of the Adult Rat's Brain

194

Digital mammography: more microcalcifications, more columnar cell lesions without atypia  

British Library Electronic Table of Contents (United Kingdom)

The incidence of columnar cell lesions in breast core needle biopsies since full-field digital mammography in comparison with screen-filmed mammography was analyzed. As tiny microcalcifications characterize columnar cell lesions at mammography, we hypothesized that more columnar cell lesions are diagnosed since full-field digital mammography due to its higher sensitivity for microcalcifications. In all, 3437 breast core needle biopsies performed in three hospitals and resulting from in total 55?159 mammographies were revised: 1424 taken in the screen-filmed mammography and 2013 in the full-field digital mammography period. Between the screen-filmed mammography and full-field digital mammography periods, we compared the proportion of mammographies that led to core needle biopsies, the...

2011-01-01

195

"Paratrigeminal" paralysis of the oculopupillary sympathetic system  

UK PubMed Central (United Kingdom)

Raeder described five patients with mixed features of trigeminal nerve pathology and oculosympathetic impairment, with or without other cranial nerve lesions. This constellation of clinical features...Full Text Available

2002-03-01

196

Supervision monitoring for radiation environment around Daya Bay and Lingao nuclear power stations  

International Nuclear Information System (INIS)

This paper systematically introduces the supervision monitoring for radiation environment around the Guangdong Daya Bay and Ling Ao nuclear power station by the Guangdong Environmental Radiation Research and Monitoring Center. It includes the monitoring plan, methods, quality assurance, main results and conclusions. The results show that: (1) The gas discharge have not caused any detectable impacts to the terrestrial and atmospheric environment since their operation; (2) "1"1"0"mAg could only be detected in seawater in the West Daya Bay in 1995 and 1997 and in sediments in 1997. The maximum annual average in seawater was 3.1 Bq/m"3, annual average of "1"1"0"mAg in sediments was 1.0 Bq/kg(dry). But it was always detectable in pearl oyster, gulfweed and cuttlefish in the West Daya Bay. The "1"1"0"mAg concentrations in halobios were relatively higher in 1994, 1996 and 1997. The maximum concentrations in ...

2004-05-01

197

Status of the WAND (Waste Assay for Nonradioactive Disposal) project as of July 1997  

Energy Technology Data Exchange (ETDEWEB)

The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform the data analysis. WAND system minimum detectable activities (MDAs) for point sources ...

1998-03-01

198

Optical chemical sensors for atmospheric pollutants based on nano porous materials: application to the formaldehyde and the other carbonyl compounds; Capteurs chimiques a transduction optique de polluants atmospheriques a base de materiaux nanoporeux: application au formaldehyde et autres composes carbonyles  

Energy Technology Data Exchange (ETDEWEB)

Formaldehyde, a well-identified indoor pollutant, was recently classified as carcinogenic. New regulations for the air quality are expected and therefore there is a need for low-cost sensors, sensitive and selective with a fast response time for the detection of formaldehyde at ppb level. In the present work, we had developed a chemical sensor based on nano-porous matrices doped with Fluoral-P and optical methods of detection. The nano-porous matrices, elaborated via the Sol-Gel process, display nano-pores whose cavity is tailored for the trapping of the targeted pollutant. They provide a first selectivity with the discrimination of the pollutants by their size. A second selectivity is obtained with a molecular probe, Fluoral-P, which reacts specifically with formaldehyde leading to the 3,5- di-acetyl-1,4-dihydro-lutidine (DDL). The kinetics of formation of DDL was studied as function of many parameters such as the ...

2006-12-15

199

Endovascular transplantation of stem cells to the injured rat CNS  

Energy Technology Data Exchange (ETDEWEB)

Transplantation procedures using intraparenchymal injection of stem cells result in tissue injury in addition to associated surgical risks. Intravenous injection of mesenchymal stem cells gives engraftment to lesions, but the method has low efficiency and specificity. In traumatic brain injuries (TBI), there is a transient breakdown of the blood-brain barrier and an inflammatory response, which increase migration of cells from blood to parenchyma. The aim of this investigation was to analyze the effect of intra-arterial administration on cellular engraftment. Experimental TBI was produced in a rat model. Endovascular technique was used to administer human mesenchymal stem cells in the ipsilateral internal carotid artery. Evaluation of engraftment and side effects were performed by immunohistochemical analysis of the brain and several other organs. The results were compared to intravenous administration of stem cells. Intra-arterial transplantion of mesenchymal stem ...

2009-10-15

200

Diagnosis and treatment of Ewing's sarcoma  

International Nuclear Information System (INIS)

Ewing's sarcoma is a small round-cell tumor typically arising in the bones, rarely in soft tissues, of children and adolescents. Ewing's sarcoma has retained the most unfavorable prognosis of all primary musculoskeletal tumors. Prior to the use of multi-drug chemotherapy, long-term survival was less than 10%. The development of multi-disciplinary therapy with chemotherapy, irradiation, and surgery has increased current long-term survival rates in most clinical centers to greater than 50%. In addition, the preferred method of tumor resection has changed; limb salvage has nearly replaced amputation of the affected limb. Limb salvage procedures can be performed in place of amputation without compromising patient survival rates. Recent studies have revealed that the pathognomonic translocations involving the EWS gene on chromosome 22 and an ETS-type gene, which is most commonly the Fli1 gene on chromosome 11, are implicated in more than 95% of Ewing's sarcomas, primitive neuroectodermal ...

2007-02-01

201

A genetic model of melanoma tumorigenesis based on allelic losses  

Energy Technology Data Exchange (ETDEWEB)

Previous karyotypic studies have indicated a possible series of non-random chromosomal events involved in the progression of melanoma. We sought to define a model of melanocyte tumorigenesis by studying allelic deletions of polymorphic simple tandem repeat markers mapping to chromosome 1, 6q, 7, 9p, 10, 11, 17, and 21 in thirty matched pairs of melanoma and constitutional DNAs. The most frequent and earliest deletions were found on 9p (57%) and 10q (32%) and with the exception of one case, no sample has loss of markers on another chromosome without concomitant loss of markers on 9p and/or 10q. Losses on 6q were also a frequent (32%) event that sometimes occurred in primary melanomas, whereas losses of loci on distal 1p (26%) or 11q (26%) occurred only in metastic melanomas. A background rate (0-17%) of allele loss was seen on chromosomes 7, 17, and 21. Homozygous deletions in a panel of 31 melanoma cell lines were only detected for markers on 9p (4 cases). These ...

1994-09-01

202

A Clinical Study on the Value of a Scoring System of the Scanning Images in Liver Cirrhosis  

International Nuclear Information System (INIS)

Although the radioisotope liver scan has primarily been of use in the detection of the intra-hepatic space occupying lesions, there has been an increasing awareness of its use in evaluation of liver function. In this study, the degree of hepatomegaly, changes in shape and mottling radiodensity on each lobe and splenic visualization in the liver scans done with colloidal radiogold were numerically expressed as scores under the arbitrary standard in 210 patients with liver cirrhosis. The clinical value of this scoring system was studied with special regards to the correlation between the radiogold hepatic uptake half time and conventional liver function tests. Following were the results; 1) The normal scan appeared in 6.7% of 210 patients with liver cirrhosis. 2) The colloidal radiogold hepatic uptake half time was abnormally and progressively prolonged in parallel to severity of hepatocellular dysfunction. The mean hepatic uptake half time in ...

1970-09-01

203

Percutaneous therapy of inoperable biliary stenoses and occlusions with a new self-expanding nitinol stent (SMART); Perkutane Therapie inoperabler maligner Stenosen und Verschluesse der Gallenwege mit einem neu entwickelten selbstexpandierbaren Nitinolstent (SMART)  

Energy Technology Data Exchange (ETDEWEB)

Objective: To evaluate the treatment of malignant biliary stenoses and occlusions using a new stent. Methods: In a prospective study, 25 patients with malignant obstructive jaundice were treated with SMART stents. The handling and the quality of stent expansion were documented. Stent function was assessed 2-4 days after intervention by cholangiography and laboratory tests. A follow-up was performed three months, after stent placement. Results: All lesions were treated successfully, with a total of 35 stents implanted. In 14 patients a further balloon dilatation was performed after stent placement (8-10 mm diameter/40-80 mm length). The mean serum bilirubin level decreased significantly from 11.6 mg/dl to 4.6 mg/dl after intervention (p<0.05). The follow-up showed a mean serum bilirubin level at 4.0 mg/dl. In 4 cases (16%) a further intervention (PTCD or stent) was performed. Six patients died due to tumor progression. The stents proved ...

2002-10-01

204

Advantages of magnification in digital phase-contrast mammography using a practical X-ray tube  

Energy Technology Data Exchange (ETDEWEB)

Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point source results in a phase contrast too narrow for detection with CR. In addition to phase contrast improving image quality, a re-scaling effect ...

2008-12-15

205

[Heart injuries: diagnosis and therapy].  

Science.gov (United States)

The clinical manifestation of wounds of the heart is determined by the mode, site and size of the injury as well as the structure of the pericardial and myocardial lesion. Diagnosis can be confirmed by ECG and echocardiography. Only 20% of the patients with penetrating wounds of the heart live for more than 30 minutes. Pericardio-centesis should be used only to gain time for a safe sternotomy, cardiac decompression and suture of the wound of the heart. An aggressive surgical approach is mandatory. Cardiopulmonary bypass is necessary only to correct of concomitant lesions. PMID:1983618

1990-01-01

206

Radiological diagnosis of lesions of intervertebral discs  

International Nuclear Information System (INIS)

During their life, intervertebral discs undergo degenerative changes which need not necessarily become lesions. Conventional X-rays do not provide information on the condition of the intervertebral discs, so MRT or CT are recommended as primary techniques as they are non-invasive. Invasive methods like myelography and especially discography should not be used unless a case is highly problematic. In infants with pains in the back, MRT should be carried out as early as possible as there is nearly always an organic cause. (orig.)

2003-03-01

207

Needle aspiration biopsy in the diagnosis of lytic bone lesions in histiocytosis X, Ewing's sarcoma and neuroblastoma  

International Nuclear Information System (INIS)

Cytologic smears obtained by needle aspiration biopsy of lytic bone lesions in 15 patients with histiocytosis X, Ewing's sarcoma and neuroblastoma were reviewed. After conventional staining, histiocytosis X could be diagnosed and differentiated from small cell tumours such as Ewing's sarcoma and neuroblastoma. The need for sampling material for cytochemical and ultrastructural analysis of these small cell tumours by needle aspiration is emphasized. (Auth.).

208

Ewing's sarcoma of the sacrum  

International Nuclear Information System (INIS)

A lytic lesion with softtissue extension in the sacrum of a 47-year old man was needle-biopsied under computed tomographic (CT) guidance using an 18-gauge cutting needle. The cytologic appearance of the lesion and immunohistochemical staining were diagnostic of Ewing's sarcoma. Specifically, a new marker (O13) for the presence of glycoprotein p30/32 mic2 in Ewing's sarcoma was utilized. (orig.).

209

Comparison of gadobenate dimeglumine (Gd-BOPTA) with gadopentetate dimeglumine (Gd-DTPA) for enhanced MR imaging of brain and spine tumours in children  

International Nuclear Information System (INIS)

Sixty-three subjects, aged 6 months to 16 years, who were enrolled in a prospective, fully blinded, randomized parallel-group phase III clinical trial, received 0.1 mmol/kg doses of either Gd-BOPTA (n=29) or Gd-DTPA (n=34). The MR images were acquired before and within 10 min of contrast agent injection. The primary objective was to compare the difference from pre-dose to post-dose lesion visualization between Gd-BOPTA and Gd-DTPA. Lesion visualization was determined as the sum of individual scores for three criteria of lesion morphological characteristics (lesion border delineation, internal morphology, and contrast enhancement), each assessed qualitatively using 4-point scales. Quantitative evaluation compared changes in lesion-to-background (LBR) and contrast-to-noise (CNR) ratios and per cent enhancement. Monitoring for adverse events and evaluation of vital signs and laboratory ...

2005-05-01

210

CT manifestations of ileal dysgenesis  

Energy Technology Data Exchange (ETDEWEB)

Ileal dysgenesis is an uncommon condition of unknown etiology occurring in the distal ileum in the region of the vitelline duct. The CT appearance of this lesion, although not previously described to our knowledge, is characteristic. We report a patient with ileal dysgenesis who had an abdominal CT scan to evaluate chronic iron deficiency anemia and protein-losing enteropathy. Recognition of this lesion by pediatric radiologists is important; so that surgical treatment, which is simple and effective, can be initiated quickly. (orig.)

2007-02-15

211

Both the Fas Ligand and Inducible Nitric Oxide Synthase Are Needed for Control of Parasite Replication within Lesions in Mice Infected with Leishmania major whereas the Contribution of Tumor Necrosis Factor Is Minimal  

UK PubMed Central (United Kingdom)

Following infection with the protozoan parasite Leishmania major, C57BL/6 mice develop a small lesion that heals spontaneously. Resistance to infection is associated with the development...Full Text Available

2003-09-01

212

Soft tissue signal abnormality associated with eosinophilic granuloma. Correlation of MR imaging with pathologic findings  

Energy Technology Data Exchange (ETDEWEB)

Six patients with eosinophilic granuloma were studied retrospectively in order to correlate the MRI appearances with the pathology. Ages ranged from 2 years 6 months to 11 years. The bones involved were the humerus, ulna, radius, femur, clavicle and ilium. Plain films, MRI and pathology specimens were obtained. A lytic lesion with indistinct margins, endosteal erosions and periosteal reaction was seen in all cases on plain radiographs. Bone marrow signal was decreased on T1-weighted images and increased on T2-weighted images throughout the bony lesion in all cases. T2-weighted images showed extensive soft-tissue abnormalities suggesting inflammatory changes in four cases. In two cases abnormalities were limited. Extensive changes correlated histologically with an early phase lesion. Localized minor changes were associated with a mid-phase lesion. Inflammatory soft-tissue changes could be associated with ...

1994-09-01

213

Intracranial tuberculoma: MR imaging  

International Nuclear Information System (INIS)

MR studies of 6 patients with intracranial tuberculoma are reviewed. All patients also underwent CT scans which showed hypo- or isodense lesions with abnormal enhancement following contrast administration. MR showed lesions with prolongation of the T1 relaxation time in every case. On the T2-weighted sequences, the signal properties of the tuberculoma varied according to the stage of evolution of the lesion. Incipient tuberculomas appeared as scattered areas of hypointensity surrounded by edema. Mature tuberculomas were composed of a dark necrotic center surrounded by an isointense capsule which was, in turn, surrounded by edema. In one patient, the center of the lesion was hyperintense probably because of liquefaction and pus formation (tuberculous abscess). While both, CT and MR, were equally sensitive in visualizing the intracranial tuberculoma in every patient, MR was slightly superior in ...

1988-11-01

214

The importance of radiation quality for optimisation in radiology  

UK PubMed Central (United Kingdom)

Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available

215

Quality assurance handbook for measurement laboratories  

International Nuclear Information System (INIS)

This handbook provides guidance in the application of quality assurance to measurement activities. It is intended to help those persons making measurements in applying quality assurance to their work activities by showing how laboratory practices and quality assurance requirements are integrated to provide control within those activities. The use of the guidance found in this handbook should help provide consistency in the interpretation of quality assurance requirements across all types of measurement laboratories. This handbook also can assist quality assurance personnel in understanding the relationships between laboratory practices and quality assurance requirements. The handbook is composed of three chapters and several appendices. Basic guidance is provided by the three chapters. In Chapter 1, the role of quality assurance in obtaining ...

216

Value of contrast-enhanced MRI of breast after silicone implant; Wertigkeit der Kontrastmittelmagnetresonanztomographie der Mamma bei Wiederaufbau mittels Implantat  

Energy Technology Data Exchange (ETDEWEB)

Early recognition of recurrence and work-up of clinically indeterminate lesions may be impaired after reconstruction with silicone implants due to superimposition of the implant or to scarring. This study was undertaken to evaluate the use of contrast-enhanced MRI in patients with silicone implant after breast cancer. Contrast-enhanded MRI was offered to 169 patients. Comparative two- to three-view mammography was also performed in 169 patients, as well as comparative sonography in 144 patients. Conventional imaging and clinical examination detected only 8/13 recurrences, whereas 12/13 were detected by MRI. One recurrence had been visible as a strongly enhancing 2-mm dot in a previous examination (2 years before), but was not called. It was therefore counted as false negative. In addition, multicentricity was detected by MRI alone in two of three cases. MRI correctly diagnosed scar tissue in all cases ...

1997-09-01

217

Statistical Methods and Software for the Analysis of Occupational Exposure Data with Non-detectable Values  

Energy Technology Data Exchange (ETDEWEB)

Environmental exposure measurements are, in general, positive and may be subject to left censoring; i.e,. the measured value is less than a ''detection limit''. In occupational monitoring, strategies for assessing workplace exposures typically focus on the mean exposure level or the probability that any measurement exceeds a limit. Parametric methods used to determine acceptable levels of exposure, are often based on a two parameter lognormal distribution. The mean exposure level, an upper percentile, and the exceedance fraction are used to characterize exposure levels, and confidence limits are used to describe the uncertainty in these estimates. Statistical methods for random samples (without non-detects) from the lognormal distribution are well known for each of these situations. In this report, methods for estimating these quantities based on the maximum likelihood method for randomly left censored ...

2005-09-20

218

Intelligent Extruder  

Energy Technology Data Exchange (ETDEWEB)

''Intelligent Extruder'' described in this report is a software system and associated support services for monitoring and control of compounding extruders to improve material quality, reduce waste and energy use, with minimal addition of new sensors or changes to the factory floor system components. Emphasis is on process improvements to the mixing, melting and de-volatilization of base resins, fillers, pigments, fire retardants and other additives in the :finishing'' stage of high value added engineering polymer materials. While GE Plastics materials were used for experimental studies throughout the program, the concepts and principles are broadly applicable to other manufacturers materials. The project involved a joint collaboration among GE Global Research, GE Industrial Systems and Coperion Werner & Pleiderer, USA, a major manufacturer of compounding equipment. Scope of the program included development ...

2003-04-24

219

Chemical, sensory and microbiological changes of gamma irradiated coconut cream powder  

Energy Technology Data Exchange (ETDEWEB)

A study was carried out to determine optimum decontamination dose for a locally manufactured coconut cream powder. Samples were gamma irradiated (0-15 kGy) and ageing process was achieved using GEER oven at 60 deg. C for 7 days, which is equivalent to one-year storage at room temperature. Iodine value (IV), ranging from 4.8 to 6.4, was not affected by radiation doses and storage, however peroxide value and thiobarbituric acid (TBA) generally increased with radiation doses. In most samples, peroxide value (meq/kg) reduced after storage, whilst the TBA (mg malonaldehyde/kg), indicator for product quality, slightly increased. The sensory evaluation conducted using 25 taste panellists indicated that scores on odour, creamy taste and overall acceptance for all irradiated samples at more than 5 kGy were significantly lower (P<0.05) than the control. However, the panellists could not detect any significant differences among the irradiation ...

2007-11-15

220

A study of neutron room scattering at RPCF  

International Nuclear Information System (INIS)

High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers dosimeters use CR39 for neutron detection, ...

1997-01-05

221

A study of neutron room scattering at RPCF  

Energy Technology Data Exchange (ETDEWEB)

High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers dosimeters use CR39 for neutron detection, ...

1996-09-01

222

Ultrasensitive fluorescence detection of DNA  

Science.gov (United States)

Progress on Ultrasensitive fluorescence detection of DNA is briefly described. (CBS)

1991-01-01

224

Fluorescent Silicate Materials for the Detection of Paraoxon  

Science.gov (United States)

... significantly lower limits of detection. The complex fluorescence spectra of these constructs indicated that only a portion ...

2010-03-19

225

Helical CT of traumatic injuries of the thoracic aorta; Applicazioni della Tomografia Computerizzata spirale nello studio delle lesioni traumatiche dell'aorta toracica  

Energy Technology Data Exchange (ETDEWEB)

Acute thoracic aortic injuries account for up to 10-20% of fatalities in high-speed deceleration road accidents and have an estimated immediate fatality rate of 80-90%. Untreated survivors to acute trauma (10-20%) have a dismal prognosis: 30% of them die within 6 hours, 40-50% die within 24 hours, and 90% within 4 months. It was investigated the diagnostic accuracy of Helical Computed Tomography (Helical CT) in acute traumatic injuries of the thoracic aorta, and the role of this technique in the diagnostic management of trauma patients with a strong suspicion of aortic rupture. It was compared retrospectively the chest Helical CT findings of 256 trauma patients examined June 1995 through August 1999. Chest Helical CT examinations were performed according to trauma score, to associated traumatic lesions and to plain chest radiographic findings. All the examinations were performed with no intravenous contrast agent administration and the pitch 2 technique. After a ...

2000-09-01

226

Water Quality and 401 Certification | Clean Water Act | US EPA  

Science.gov (United States)

Clean Water Act You are here: Water Laws & Regulations Policy & Guidance Clean Water Act Water Quality and 401 Certification Water Quality and 401 Certification Water Quality...

2011-08-28

236

EPA: Environmental Quality and Recreation: Global Warming  

Science.gov (United States)

Archived Web resource. Information about the impacts of global warming on the environmental quality and recreation, such as ... ...

237

Radioguided occult lesion localization versus wire-guided localization for non-palpable breast lesions: randomized controlled trial  

Scientific Electronic Library Online (English)

Abstract in english AIM: This prospective randomized clinical study was conducted to compare radioguided occult lesion localization (ROLL) with wire-guided localization to evaluate optimum localization techniques for non-palpable breast lesions. METHODS: A total of 108 patients who were undergoing an excisional biopsy for non-palpable breast lesions requiring pathologic diagnosis were randomly assigned to the ROLL group (n = 56) and wire-guided localization group (n = 52). In the study, pati (more) ents' characteristics, radiological abnormalities, radiological technique of localization, localization time, operation time, weight of the excised specimen, clearance margins, pathological diagnosis and perioperative complications were assessed. RESULTS: There were no differences between the two groups in terms of age, radiological abnormalities and localization technique (p = non-significant for all). ROLL techniques resulted ...

2011-01-01

238

Percutaneous intervention in the menagement of insufficient native arteriovenous hemodialysis fistulae  

Energy Technology Data Exchange (ETDEWEB)

To determine the effectiveness and patency of percutaneous intervention in insufficient native arteriovenous hemodialysis fistulae (AVFs). Between March 1997 and September 2001, 67 cases of insufficient native AVFs resulted from central vein lesion, PTA was performed in 48 cases, and thrombolytic therapy with or without PTA in 11. In eight of the cases, in which central vein stenosis had led to the insufficency, percutaneous transluminal angioplasty (PTA) was performed, and in three of the eight, a stent was inserted. Angiography findings and complications, as well as success and patency rates in the non-thrombosis and thrombosis group, were evaluated; the central vein lesion group was analysed separately. Among 84 lesions observed at angiography, three were 54 cases of stenosis, 17 of occlusion, and 13 of combined thrombosis. The lesions were located in a proximal vein (n=51), distal vein (n=14), ...

2002-11-01

239

Distinguishing benign notochordal cell tumors from vertebral chordoma  

Energy Technology Data Exchange (ETDEWEB)

The objective was to characterize imaging findings of benign notochordal cell tumors (BNCTs). Clinical and imaging data for 9 benign notochordal cell tumors in 7 patients were reviewed retrospectively. Conventional radiographs (n = 9), bone scintigrams (n = 2), computed tomographic images (n = 7), and magnetic resonance images (n = 8) were reviewed. Eight of the 9 lesions were stained with hematoxylin-eosin and microscopically examined. There were 3 male and 4 female patients with an age range of 22 to 55 years (average age, 44 years). Two patients had two lesions at different sites. The lesions involved the cervical spine in 4 patients, the lumbar spine in 2, the sacrum in 2, and the coccyx in 1. The most common symptom was mild pain. The lesions of 2 patients were found incidentally during imaging studies for unrelated conditions. Five patients underwent surgical procedures. One patient died of ...

2008-04-15

240

Imaging-based dust sensors: equipment and methods  

Science.gov (United States)

Dust detection and control in real time, represent one of the most challenging problem in all those environments where fine and ultrafine airborne particulate solids products are present. The presence of such products can be linked to several factors, often directly related and influenced by the working-production actions performed. Independently from the causes generating dust, airborne contaminants are an occupational problem of increasing interest as they are related to a wide number of diseases. In particular, airborne dusts are well known to be associated with several classical occupational lung diseases, such as the pneumoconiosis, especially at high levels of exposure. Nowadays there is also an increasing interest in other dust related diseases, from the most serious as cancer and asthma, to those related with allergies or irritation and other illnesses, also occurring at lower levels of exposure. Among the different critical factors influencing health risk ...

2004-05-01

241

Serial Intravascular Ultrasound Analysis of the Impact of Myocardial Bridge on Neointimal Proliferation After Coronary Stenting in Patients with Acute Myocardial Infarction  

British Library Electronic Table of Contents (United Kingdom)

Background: Mechanisms underlying the association between myocardial bridge (MB)-stenting and in-stent restenosis (ISR) are still unclear. Objective: To assess the impact of MB on ISR using intravascular ultrasound (IVUS). Methods: In the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) trial, 100 left anterior descending artery (LAD) culprit lesions (79 treated with paclitaxel-eluting stents [PES] and 21 treated with bare metal stents) were imaged with serial IVUS immediately postprocedure and at 13 months. Results: At baseline the LAD stent extended into the MB segment beyond the culprit lesion in seven patients (MB-stent group). In the remaining 93 patients the LAD stent was implanted only in the culprit lesion without extending into t...

2010-01-01

242

Cost minimization analysis for combinations of sampling techniques in bronchoscopy of endobronchial lesions  

British Library Electronic Table of Contents (United Kingdom)

SummaryBackground The choice of sampling techniques in bronchoscopy with sampling from a visible lesion will depend on the expected diagnostic yields and the costs of the sampling techniques. Aims The aim of this study was to determine the most economical combination of sampling techniques when approaching endobronchial visible lesions. Methods A cost minimization analysis was performed. All bronchoscopies from 2003 and 2004 at Haukeland university hospital, Bergen, Norway, were reviewed retrospectively for diagnostic yields. 162 patients with endobronchial disease were included. Potential sampling techniques used were biopsy, brushing, endobronchial needle aspiration (EBNA) and washings. Costs were estimated based on registration of equipment costs and personnel costs. Sensitivity analyse...

2009-01-01

243

Clinical Evaluation of the Zilver Vascular Stent for Symptomatic Iliac Artery Disease  

British Library Electronic Table of Contents (United Kingdom)

PurposeTo evaluate the safety and effectiveness of the Zilver vascular stent in the treatment of de novo or restenotic lesions in the external and common iliac arteries.Materials and MethodsRegardless of the results of an initial percutaneous transluminal angioplasty (PTA), 151 consecutive patients were implanted with Zilver vascular stents (Cook, Bloomington, Ind) in up to two stenotic (?10 cm) or occluded (?5 cm) atherosclerotic lesions of the external or common iliac arteries. The primary endpoint was the rate of major adverse events within 9 months after the procedure. Major adverse events were defined as death, myocardial infarction, target lesion revascularization, and limb loss. Secondary endpoints included acute procedural success, 30-day clinical success, 9-month pat...

2008-01-01

244

Comparison of high resolution whole-body MRI using parallel imaging and PET-CT. First experiences with a 32-channel MRI system; Hochaufloesendes Ganzkoerpertumorstaging unter Verwendung paralleler Bildgebung im Vergleich zur PET-CT. Erste Erfahrungen auf einem 32-Kanal-MRT-System  

Energy Technology Data Exchange (ETDEWEB)

To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI scanner (Magnetom Avanto, Siemens Medical Solutions) with a total field of view of 205 cm and free table ...

2004-09-01

245

Tissue equivalent proportional counter real time neutron monitor  

International Nuclear Information System (INIS)

The Tissue Equivalent Proportional Counter (TEPC) was developed to monitor low level neutron exposure rates at working stations in a nuclear fuel fabrication facility. It has proven capable of accurately measuring neutron dose rates at levels from 0.1 to 0.2 mrem/hr. It also calculates the Quality Factor which is of importance in locations where the neutron to gamma ratio may vary significantly and irregularily. The system described is computerized to monitor 100 work locations simulationeously and can be expanded to monitor 384 locations. Neutron dose is accumulated on a real time basis and after the proton drop point is established, dose rate can be read out at any time for the dose accumulated over a specified period of time. The current development program which provides reduced system maintenance, lower detection limits, and improved accuracy is discussed along with examples of measurement data and work experience with the current system.

1978-10-25

246

Time-Resolved Aerosol Collector for CCSEM/EDX Single Particle Analysis  

Energy Technology Data Exchange (ETDEWEB)

An automated Time Resolved Aerosol Collector (TRAC) has been developed for sequential sampling of field-collected aerosols for laboratory-based Computer Controlled Scanning Electron Microscopy/Energy Dispersed X-ray (CCSEM/EDX) single particle analysis. The collector is optimized for use of grid-supported 20 nm carbon films as deposition substrates. The carbon films have low enough X-ray background to permit EDX analysis down to 0.1-0.2 ?m particles, including detection of low-Z elements: C, N, & O. The TRAC provides unattended sampling onto a set of 151 individual grids, at sequential time intervals as short as 1 min. After collection, the samples are sealed and refrigerated pending analysis. The utility of the TRAC-CCSEM/EDX approach is exemplified using the aerosol samples collected during the Texas 2000 Air Quality Studies (Aug. 15 ? Sept. 15, 2000). We are able to quantitatively follow the time evolution in the relative contribution of ...

2003-01-02

247

The application of the Fuji Computed Radiography system for the diagnosis of pneumoconiosis; Determination of optimum conditions of image processing  

Energy Technology Data Exchange (ETDEWEB)

A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above mentioned image processings are adopted, FCR can be used for the diagnosis of pneumoconiosis with the same ...

1993-06-01

248

The application of the Fuji Computed Radiography system for the diagnosis of pneumoconiosis  

International Nuclear Information System (INIS)

A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above mentioned image processings are adopted, FCR can be used for the diagnosis of pneumoconiosis with the same ...

1993-01-01

249

Test Bed for Superconducting Materials  

Energy Technology Data Exchange (ETDEWEB)

Superconducting rf cavities are increasingly used in accelerators. Gradient is a parameter of particular importance for the ILC. Much progress in gradient has been made over the past decade, overcoming problems of multipacting, field emission, and breakdown triggered by surface impurities. However, the quenching limit of the surface magnetic field for niobium remains a hard limitation on cavity fields sustainable with this technology. Further exploration of materials and preparation may offer a path to surpassing the current limit. For this purpose, we have designed a resonant test cavity. One wall of the cavity is formed by a flat sample of superconducting material; the rest of the cavity is copper or niobium. The H field on the sample wall is 75% higher than on any other surface. Multipacting is avoided by use of a mode with no surface electric field. The cavity will be resonated through a coupling iris with high-power rf at superconducting temperature until the sample wall quenches, ...

2006-01-30

250

Technology for enhancing chest auscultation in clinical simulation.  

Science.gov (United States)

The ability to use an acoustic stethoscope to detect lung and/or heart sounds, and then to then communicate one's interpretation of those sounds is an essential skill for many medical professionals. Interpretation of lung and heart sounds, in the context of history and other examination findings, often aids the differential diagnosis. Bedside assessment of changing auscultation findings may also guide treatment. Learning lung and heart auscultation skills typically involves listening to pre-recorded normal and adventitious sounds, often followed by laboratory instruction to guide stethoscope placement, and finally correlating the sounds with the associated pathophysiology and pathology. Recently, medical simulation has become an important tool for teaching prior to clinical practice, and for evaluating bedside auscultation skills. When simulating cardiovascular or pulmonary problems, high-quality lung and heart sounds should be able to ...

2011-02-11

251

Study of metal concentration in sediment of some springs of Lebanon  

International Nuclear Information System (INIS)

Full text.Surficial sediment samples were collected from seventeen springs distributed all over Lebanon (east, west, north and south). Concentrations of metals Ca, Fe, Mn, Ni, Cu, Cr, Zn and Pb were determined by energy dispersive x-ray fluorescence technique. Irradiation was done by the radioisotope source Cd-109 and the detection by an EG and G Si(Li) detector. These analysis was done in attempt to assess the impact of anthropogenic sources on ground water quality. Metals concentration in sediment were found to be (Ca:0.05-47%, Fe:0.24-4.2%, Cr:

1999-11-02

252

Single exposure energy subtraction chest radiography in the diagnosis of pulmonary cancer  

Energy Technology Data Exchange (ETDEWEB)

A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is considered to be one of the routine examinations, in view of low exposure doses. The need of conventional ...

1987-03-01

253

Single exposure energy subtraction chest radiography in the diagnosis of pulmonary cancer  

International Nuclear Information System (INIS)

A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is considered to be one of the routine examinations, in view of low exposure doses. The need of conventional ...

1987-01-01

254

Quantitative bone scintigraphy in renal osteodystrophy  

International Nuclear Information System (INIS)

The need for noninvasive sensitive techniques for the diagnosis and follow-up of metabolic bone disease in dialysis patients has stimulated the author's interest in the efficacy of more detailed quantitative bone scintigraphy. Using hemodialysis to reduce elevated soft-tissue activity at scintigraphy, an attempt was made to assess the diagnostic sensitivity of quantitative bone scintigraphy as compared to qualitative bone scintigraphic, biochemical, radiographic and bone histologic studies. The second aim of these studies was to determine if one of the two major components of renal osteodystrophy is a major determinant for skeletal radiotracer uptake. The clinical observations on the efficacy and possible specificity of quantitative bone scintigraphy in the diagnosis and follow-up during treatment of renal osteodystrophy are presented briefly in this chapter. Thus, the use of scintigraphy for the routine detection and follow-up of renal osteodystrophy in dialysis ...

255

Phthalate monoesters in perfusate from a dual placenta perfusion system, the placenta tissue and umbilical cord blood.  

Science.gov (United States)

Fetal exposure to phthalates may be associated with adverse reproductive effects, including cryptorchidism and decreased semen quality. Information about human placental transfer is needed to qualify the hypotheses. A dual recirculating placenta perfusion system to monitor concentrations of eight phthalate monoesters in fetal and maternal perfusates was established. In addition to perfusate background measures of phthalate monoesters, the concentrations in umbilical cord plasma and placenta tissue were measured. Monomethyl phthalate (mMP), monoethyl phthalate (mEP), monobutyl phthalate (mBP), and mono (2-ethyl-hexyl) phthalate (mEHP) were detected in both maternal and fetal perfusate, demonstrating a release of compounds from tissue or blood to perfusates. The distribution of compounds between perfusate, umbilical cord plasma, and tissue was in accordance with the physical-chemical properties of the compounds. Results from the present study of ...

2006-09-01

256

Firewall Configuration Errors Revisited  

CERN Document Server

The first quantitative evaluation of the quality of corporate firewall configurations appeared in 2004, based on Check Point FireWall-1 rule-sets. In general that survey indicated that corporate firewalls were often enforcing poorly written rule-sets, containing many mistakes. The goal of this work is to revisit the first survey. The current study is much larger. Moreover, for the first time, the study includes configurations from two major vendors. The study also introduce a novel "Firewall Complexity" (FC) measure, that applies to both types of firewalls. The findings of the current study indeed validate the 2004 study's main observations: firewalls are (still) poorly configured, and a rule-set's complexity is (still) positively correlated with the number of detected risk items. Thus we can conclude that, for well-configured firewalls, ``small is (still) beautiful''. However, unlike the 2004 study, we see no significant indication that later ...

2009-01-01

257

DOE personnel neutron dosimetry evaluation and upgrade program  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. An Effective Dose Equivalent System is ...

1988-10-01

258

Consequences of warm-up of a sector above 80K  

CERN Document Server

There may be circumstances when a sector has to be partially or totally warmed-up to temperatures above 80 K, that is when thermal dilatation starts to play a role. Some equipment have been identify as presenting a risk, like the non-conform "plug-in" modules in the arcs. Because of motion induced by thermal dilatation, the electrical (ElQA) quality control may also have to be done again after cool-down. The main reason identified so far for partial warm-up is the required maintenance of the cooling towers and the cryogenics plants. There is also the request from the vacuum group to periodically warm-up the beam screen to temperatures in the 100 K region to release and pump-out the gas crysorbed on the surface of the beam screen. Observed and expected temperature conditions and statistics on failures of PIMs in sectors which have been warmed-up will be presented in this contribution. Methods to detect buckled PIMs will be described, as well as ...

2009-01-01

259

Concrete as secondary containment for interior wall embedded waste lines  

International Nuclear Information System (INIS)

Throughout the DOE complex there are numerous facilities that handle hazardous and radioactive waste solutions. Due to the hazardous constituents of the mixed waste, secondary containment of tank systems and their ancillary piping, in accordance with Resource Conservation and Recovery Act, is a concern for such existing facilities. The Idaho Division of Environmental Quality was petitioned in 1990 for an Equivalent Device determination regarding secondary containment of waste lines embedded in interior concrete walls. The petition was granted; however, it expires in 1996. To address the secondary containment issue, additional studies were undertaken. One study verified the hypothesis that an interior wall pipe leak would follow the path of least resistance through the naturally occurring void found below a rigidly supported pipe and pass into an adjacent room where detection could occur, before any significant deterioration of the concrete ...

1993-08-17

260

Cesium-137 levels detected in Georgia otters  

Energy Technology Data Exchange (ETDEWEB)

Beginning in the 1940's and continuing through the 50's and early 60's, nuclear devices were tested by aerial detonation in the United States and other countries around the world. Cesium-137 (/sup 137/Cs) is one of the most important radionuclide by-products due to its abundance and slow decay (30-year half-life). The uptake of /sup 137/Cs in animal tissue is the result of its similarity to potassium. The somatic and genetic effects of /sup 137/Cs, along with its effect on reproductive cells, can pose great hazards to wildlife species. A reported buildup of /sup 137/Cs in white-tailed deer in the lower coastal plain of Georgia during the 1960's was followed by a gradual decline during the 1970's. Although numerous studies have involved terrestrial mammals of Georgia, few have involved aquatic mammals such as the river otter. With continued atmospheric testing by some foreign countries and the increased use of nuclear power as an energy ...

1988-11-01

261

Behavioral effects of exposure to the TEMPO high-power microwave system. Interim report, January-June 1987  

Energy Technology Data Exchange (ETDEWEB)

Safety standards for exposure to radiofrequency radiation must be based upon biologic consequences of exposure to such environments. Behavioral-based measures are considered to be the most-sensitive indices of biological effects. Current safety guidelines are based upon average power density and may not be relevant to the high-peak-power, short pulse width microwave radiation produced by newly developed high peak power microwave sources. The effects of exposure to high-peak-power radiation on reflexive responding and motor function in Fischer 344/N rats were assessed by measuring startle and general activity, and disruption of on-going performance of a rotarod task, respectively. The emitter used was the TEMPO repeat pulse axially extracted vircator. Exposure to single pulses resulted in significant startle responses. Exposure to 1 pps for 10 s produced significant alterations in baseline activity and marked disruption of performance of the rotarod task. The apparently greater effect ...

1988-03-01

262

Application of radionuclide X-ray fluorescence analysis to the monitoring of the quality of air  

International Nuclear Information System (INIS)

An X-ray fluorometric train was set up for analyzing gravitational fallout, and tested on standard reference samples of fly ashes from conventional power plants. Analysis of thin layers proved inappropriate, and therefore pelletization of the samples, either alone or together with the X-ray MIX binder, was applied. Sample grinding in an agate mortar was found sufficient to suppress the particle size effect. The optimum pressure was 20 MPa. The optimum geometry was sought for "1"0"9Cd source, and limits of detection of 2.78-0.47 #mu#g were achieved for Cr-Zr elements. Tominaga's method was employed for matrix effect correction. Ti, Fe, Cu, Zn, As, Rb, Sr, Zr and Pb were determined in the SRM's; the relative errors ranged from units per cent (for Zn, Rb, Sr and Zr present in concentrations about 100 ppm and for Fe in concentrations of units per cent) up to 45% (for Ti present in a concentration of 0.67%). The method developed was applied to the investigation of ...

1990-10-01

263

Air pollutants emissions from waste treatment and disposal facilities.  

Science.gov (United States)

This study examined the atmospheric pollution created by some waste treatment and disposal facilities in the State of Kuwait. Air monitoring was conducted in a municipal wastewater treatment plant, an industrial wastewater treatment plant established in a petroleum refinery, and at a landfill site used for disposal of solid wastes. Such plants were selected as models for waste treatment and disposal facilities in the Arabian Gulf region and elsewhere. Air measurements were made over a period of 6 months and included levels of gaseous emissions as well as concentrations of volatile organic compounds (VOCs). Samples of gas and bioaerosols were collected from ambient air surrounding the treatment facilities. The results obtained from this study have indicated the presence of VOCs and other gaseous pollutants such as methane, ammonia, and hydrogen sulphide in air surrounding the waste treatment and disposal facilities. In some cases the levels exceeded the concentration limits specified by ...

2006-01-01

264

A variability study of the first catalog of gamma-ray sources on the 2.3 years AGILE data archive  

Science.gov (United States)

AGILE pointed observations performed from July 9, 2007 to October 30, 2009 are a recent, high quality gamma-ray data archive for monitoring studies of medium to high brightness gamma-ray sources in the 30 MeV -50 GeV energy range. We present a variability study of the 1AGL sources over the complete AGILE pointed Observation Blocks (OBs) dataset. The first AGILE Gamma-Ray Imaging Detector (GRID) catalog (Pittori et al. 2009) included a significance-limited (4 sigma) sample of 47 sources (1AGL), detected with a conservative analysis over a first-year non-uniform sky coverage dataset. In this analysis we used data of an improved full Field of View (FOV) event filter, on a much larger (about 27.5 months) observation dataset, analyzing each OB separatedly. This data processing resulted in an improved source list as compared to the 1AGL one. We present here some results on the variability of some of these sources.

2010-01-01

265

A study of the effects of scattered radiation on radiographic quality and methods of elimination of such radiation  

International Nuclear Information System (INIS)

Many mechanical parts are subjected to stresses and strains that may eventually lead to their failure. In order to prevent the costly delays associated with equipment down-time, many parts have to be tested for weaknesses and defects when machinery is constructed or dismantled for maintenance. These procedures are known as Non-Destructive Testing (NDT) methods. Five types of non-destructive testing methods routinely used are radiographic testing, ultrasonic testing, magnetic particle inspection, liquid penetrant testing and eddy current testing. Out of these five techniques industrial radiography plays an important role in non-destructive testing to reveal interior defects in materials. In radiography almost two-thirds of the radiation reaching the film is scattered radiation which does not form the image of defects. Scattered radiation generated inside and outside a material has a very large effect on sensitivity of flaw detection since it reduces image contrast. ...

1998-02-01

266

A Cognitive Approach to Network Monitoring in Heterogeneous Environments  

DEFF Research Database (Denmark)

Introducing intelligence by means of cognition for managing, protecting, processing, and delivering of information in mobile communication systems is the way towards ubiquitous, converged and secure communications. In this context, this paper introduces the concept of quality of information (QoI). QoI means QoS while all the requirements for dependability, security, privacy and trust are satisfied at the highest possible level. This work proposes and describes an approach to network monitoring in a heterogeneous communication environment based on use of cognitive techniques and learning predictive algorithms (e.g., fuzzy logic). These methodologies are used to create an autonomy in the decision making process that is based on the calculation of key performance indicators (KPIs), which in their turn would trigger the needed radio resource management algorithms. The expected output is an improved network performance in terms of maximized throughput and faster ...

2007-01-01

267

Virtual colonoscopy (CT colonography) in the identification of colorectal cancer. A prospective study in symptomatic patients  

International Nuclear Information System (INIS)

Aim of this study was to evaluate the sensitivity of virtual colonoscopy (CT colonography) in the identification of colorectal cancer and to define the limitations and the advantages of this imaging modality, as well as indications to the examination. It was examined prospectively 62 symptomatic patients aged 36 to 82 years (28 women and 34 men). All patients underwent both conventional and virtual colonoscopy on the same day; the conventional examination allowed exploration of the entire colon. Conventional colonoscopy identified 89 lesions 3-50 mm in diameter, namely 84 benign and 5 malignant lesions. No lesions were identified in 12 patients. CT colonography identified 52 of the 89 lesions, with 57.1% diagnostic accuracy. They were 11 false positives (82.5% positive predictive value and 52.2% specificity) and 37 false negatives (24.5% negative predictive value and 58.4% sensitivity). Sensitivity was ...

2000-06-01

268

Uracil-DNA glycosylase: Structural, thermodynamic and kinetic aspects of lesion search and recognition  

UK PubMed Central (United Kingdom)

Uracil appears in DNA as a result of cytosine deamination and by incorporation from the dUTP pool. As potentially mutagenic and deleterious for cell regulation, uracil must be removed from DNA....Full Text Available

2010-03-01

269

Transcranial management of pituitary tumours with suprasellar extension.  

UK PubMed Central (United Kingdom)

A consecutive series of 101 pituitary tumours treated in the 10 year period 1968-78 has been examined, giant lesions being excluded. There were 48 female cases and 53 male, women predominating in the...Full Text Available

1979-02-01

270

Topographical Organization of Mu and Beta Band Activity Associated with Hand and Foot Movements in Patients with Perirolandic Lesions  

UK PubMed Central (United Kingdom)

To study the topographical organization of mu and beta band event-related desynchronization (ERD) associated with voluntary hand and foot movements, we used magnetoencephalographic (MEG) recordings...Full Text Available

271

The role of Holliday junction resolvases in the repair of spontaneous and induced DNA damage  

UK PubMed Central (United Kingdom)

DNA double-strand breaks (DSBs) and other lesions occur frequently during cell growth and in meiosis. These are often repaired by homologous recombination (HR). HR may result in the formation of DNA...Full Text Available

2011-09-01

272

The molecular lesion in the alpha-N-acetylgalactosaminidase gene that causes angiokeratoma corporis diffusum with glycopeptiduria.  

UK PubMed Central (United Kingdom)

Angiokeratoma corporis diffusum with glycopeptiduria is a recently recognized inborn error of glycoprotein catabolism resulting from the deficient activity of human alpha-N-acetylgalactosaminidase (E.C....Full Text Available

1994-08-01

273

The autoradiographic localization of paraquat in the lung  

International Nuclear Information System (INIS)

Paraquat poisoning in mammals results in a characteristic lung lesion manifested principally as progressive pulmonary fibrosis. Paraquat is actively concentrated into the lung but the site of uptake remains undefined. A method is described for the autoradiographic localization of paraquat in rats. Preliminary evidence for the site of uptake implicates the bronchiol. (author).

274

The SPIRIT V Study:A Clinical Evaluation of the XIENCE V Everolimus-Eluting Coronary Stent System in the Treatment of Patients With De Novo Coronary Artery Lesions  

British Library Electronic Table of Contents (United Kingdom)

ObjectivesThe SPIRIT V (A Clinical Evaluation of the XIENCE V Everolimus-Eluting Coronary Stent System in the Treatment of Patients With De Novo Coronary Artery Lesions) study is a post-market surveillance experience of the XIENCE V (Abbott Vascular, Santa Clara, California) everolimus-eluting stent (EES) in patients with higher-risk coronary anatomy. BackgroundPrevious pre-approval studies have shown the safety and efficacy of EES in highly selected groups of patients. MethodsThe SPIRIT V trial is a prospective, open label, single arm, multicenter study. Two thousand seven hundred patients with multiple de novo coronary artery lesions suitable for treatment with a planned maximum of 4 EES were enrolled at 93 centers in Europe, Asia Pacific, Canada, and South Africa. Lesions had a referenc...

2011-01-01

275

Strength training for wheelchair users.  

UK PubMed Central (United Kingdom)

Sedentary adult males with spinal lesions, all habitual wheelchair users, were allocated to exercise (n = 11) and control (n = 4) groups. A Cybex II dynamometer was used to assess peak power, average...Full Text Available

1990-03-01

276

Space and the parietal cortex  

UK PubMed Central (United Kingdom)

Current views of the parietal cortex have difficulty accommodating the human inferior parietal lobe (IPL) within a simple dorsal versus ventral stream dichotomy. In humans, lesions of the right IPL...Full Text Available

2007-01-01

277

Select spinal lesions reveal multiple ascending pathways in the rat conveying input from the male genitalia  

UK PubMed Central (United Kingdom)

The specific white matter location of all the spinal pathways conveying penile input to the rostral medulla is not known. Our previous studies using rats demonstrated the loss of low but not high threshold...Full Text Available

2010-04-01

278

Schindler disease: the molecular lesion in the alpha-N-acetylgalactosaminidase gene that causes an infantile neuroaxonal dystrophy.  

UK PubMed Central (United Kingdom)

Schindler disease is a recently recognized infantile neuroaxonal dystrophy resulting from the deficient activity of the lysosomal hydrolase, alpha-N-acetylgalctosaminidase (alpha-GalNAc). The recent...Full Text Available

1990-11-01

279

Role of CT in the assessment of the volume to be irradiated in bone metastases  

International Nuclear Information System (INIS)

In the Department of Radiology of Catholic University S. Cuore in Rome, a review was made of 342 CT examinations with a view towards optimizing the therapeutic planning in patients affected by bone metastases. All patients were submitted to radiological positioning and then to CT evaluation in order to assess the volume to be treated. In 224 cases it was not necessary to perform wide CT examination (3-5 standard tomograms being enough, 2 of which at the superior and inferior margins of the planned field). In the second group of 118 patients it was necessary to perform CT (serial axial scans) - increasing by 1-1.5 cm - up to the superior and inferior margins of the lesion. The existence of 2 types of lesions was confirmed: those involving mainly bony structures and those infiltrating the soft tissues. CT evaluation allowed the definition of the target volume to the real extension of the lesion in 14% of the whole of cases, ...

1988-01-01

280

Rifampin pharmacokinetics in children, with and without human immunodeficiency virus infection, hospitalized for the management of severe forms of tuberculosis  

UK PubMed Central (United Kingdom)

BackgroundRifampin is a key drug in antituberculosis chemotherapy because it rapidly kills the majority of bacilli in tuberculosis lesions, prevents relapse and thus enables 6-month...Full Text Available

281

Residual lung lesions after completion of chemotherapy for gestational trophoblastic neoplasia: should we operate?  

UK PubMed Central (United Kingdom)

The significance of residual lung metastasis from malignant gestational trophoblastic neoplasm (GTN) after the completion of chemotherapy is unknown. We currently do not advocate resection of these...Full Text Available

2006-01-16

282

Radiotherapy for ocular lesions by electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Radiotherapy can be very significant as the treatment for ocular lesions, eyes need to be preserved as properly as possible on their functions and cosmetics. The application of conventional X ray therapy has been gradually abandoned as conventional X ray therapy ceased to be accepted as the general treatment for malignant tumors. Consequently the necessity of electron beam therapy has been rising even as the substituted method for conventional X ray therapy. The department of radiology of Gunma University was obliged to establish a new therapy for ocular lesions, and has been trying electron beam therapy since 1973. It is concluded that electron beam therapy is not at all inferior to conventional X ray therapy as reported above. Basic therapeutic methods for ocular lesions are the following: 1) For epidermoid carcinoma, 600 rads at a time, 3600 - 4200 rads in total is applied by 8 MeV electron twice a week method. 2) For ...

1981-11-01

283

Pulmonary endothelial and bronchiolar epithelial lesions induced by 4-ipomeanol in mice.  

UK PubMed Central (United Kingdom)

The morphogenesis of pulmonary edema and bronchiolar injury induced by the toxic furan, 4-ipomeanol, was studied by combined light and transmission electron microscopy. Weanling male CD-1 mice received...Full Text Available

1985-01-01

284

Percutaneous core excision and radiofrequency thermo-coagulation for the ablation of osteoid osteoma of the spine  

UK PubMed Central (United Kingdom)

Percutaneous radiofrequency ablation is the treatment of choice for osteoid osteoma of the appendicular skeleton. However, difficulties in localizing the lesion in the spine and its proximity to neural...Full Text Available

2009-03-01

285

Pathology of tissue loss (white syndrome) in Acropora sp. corals from the Central Pacific.  

Science.gov (United States)

We performed histological examination of 69 samples of Acropora sp. manifesting different types of tissue loss (Acropora White Syndrome-AWS) from Hawaii, Johnston Atoll and American Samoa between 2002 and 2006. Gross lesions of tissue loss were observed and classified as diffuse acute, diffuse subacute, and focal to multifocal acute to subacute. Corals with acute tissue loss manifested microscopic evidence of necrosis sometimes associated with ciliates, helminths, fungi, algae, sponges, or cyanobacteria whereas those with subacute tissue loss manifested mainly wound repair. Gross lesions of AWS have multiple different changes at the microscopic level some of which involve various microorganisms and metazoa. Elucidating this disease will require, among other things, monitoring lesions over time to determine the pathogenesis of AWS and the potential role of tissue-associated microorganisms in the genesis of tissue loss. ...

2011-03-30

286

Parietal Cortex and Episodic Memory: An Attentional Account  

UK PubMed Central (United Kingdom)

The contribution of the parietal cortex to episodic memory is a fascinating scientific puzzle. On one hand, parietal lesions do not normally yield severe episodic memory deficits, but on the...Full Text Available

2008-08-01

287

Oral manifestations of HIV infection in children and adults receiving highly active anti-retroviral therapy [HAART] in Dar es Salaam, Tanzania  

UK PubMed Central (United Kingdom)

BackgroundThe aim of the study was to compare the prevalence and types of HIV-related oral lesions between children and adult Tanzanian patients on HAART with those not on HAART...Full Text Available

288

Nuclear magnetic resonance imaging of hepatic focal injuries with phased array antennae surface: apnoea or high resolution imagery?  

International Nuclear Information System (INIS)

French English ... Orig. Title Imagerie IRM des lesions focales hepatiques avec les antennes de surface en reseau phase (phased array): apnee ou imagerie haute resolution?.

1995-10-26

289

Mechanism of cell death resulting from DNA interstrand cross-linking in mammalian cells  

UK PubMed Central (United Kingdom)

DNA interstrand cross-links (ICLs) are critical cytotoxic lesions produced by cancer chemotherapeutic agents such as the nitrogen mustards and platinum drugs; however, the exact mechanism of ICL-induced...Full Text Available

2011-08-01

290

Malignant pulmonary lesion. Possible causes of CT misdiagnosis; Possibilita' di falsi negativi nella diagnosi delle neoplasie polmonari con Tomografia Computerzzata  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this work is to describe the radiological appearance of overlooked malignant pulmonary lesions at CT and to analyze the reasons of misdiagnosis. Ten patient with pulmonary lesion (PML) overlooked at forst CT examination were selected among patients with lung cancer. Endobronchial location of the tumors and their small size were the most frequent causes of misdiagnosis of PML at chest CT in the series. However, a systematic evaluation of CT scans can reduce the percentage of missed lesions. [Italian] Scopo del presente lavoro e' di descrivere le caratteristiche radiologiche delle lesioni polmonari maligne non identificate con la Tomografia Computerizzata (TC) e definire le possibili cause di errore. Sono stati esaminato 10 pazienti con tumore polmonare. Le sedi endobronchiale e centrale nonche' le piccole dimensioni delle lesioni polmonari maligne rappresentano le cause piu' ...

1999-06-01

291

Lower Urinary Obstruction in Infancy  

UK PubMed Central (United Kingdom)

This paper reviews 165 cases of lower urinary obstruction in infancy. The commonest lesions were posterior urethral valves (91) and ectopic ureterocele (34), stenosis or atresia of the urethra (8),...Full Text Available

1972-04-01

292

Local control and survival of Ewing's sarcoma in children with radiotherapy and chemotherapy without radical surgery  

International Nuclear Information System (INIS)

The present study was undertaken in 27 children with localized Ewing's sarcoma treated at our hospital. In 9 cases the lesion was central and in 18 peripheral. Treatment consisted of: 1) Chemotherapy with 6 drugs (vincristine, cyclophosphamide, methotrexate, bleomycin, dactinomycin and doxorubicin) for one year in all patients; 2) Radiotherapy in 24 patients at a dose of 30-40 Gy in the entire bone with a booster dose of 10-15 Gy in the lesion. In 7 patients debulking surgery was performed followed by irradiation. Two cases with tumor in expendable bones and one with extensive destructive lesion in the tibia underwent radical surgery. One patient suffered local recurrence (femur) and 6 developed distant metastases. The remaining 20 (74%) patients were alive and tumor-free after follow-up periods of 17-80 months. Among the 12 patients with extremity lesions who were alive, 7 (58%) had minimal or mild ...

293

Lesions of the posterior bed nucleus of the stria terminalis eliminate opposite-sex odor preference and delay copulation in male Syrian hamsters: role of odor volatility and sexual experience  

UK PubMed Central (United Kingdom)

In Syrian hamsters (Mesocricetus auratus), the expression of reproductive behavior requires the perception of social odors. The behavioral response to these odors is mediated...Full Text Available

2010-08-01

294

Late metastasis from neuroblastoma mimicking Ewing's sarcoma  

International Nuclear Information System (INIS)

The case of an unusual late metastasis of neuroblastoma to the calcaneum, appearing as a sole recurrence 9 years after surgery, is reported. The radiographic features of the osseous lesion were very suggestive of primary bone malignancy, Ewing's sarcoma as the first option, with extraosseous spread to the soft tissues. (orig.).

295

Investigation of a syndrome of sudden death, splenomegaly, and small intestinal hemorrhage in farmed deer  

UK PubMed Central (United Kingdom)

AbstractA newly recognized syndrome, characterized by sudden death of farmed deer that are in good to excellent nutritional condition, with lesions of small intestinal mucosal hemorrhage...Full Text Available

2005-08-01

296

In-vivo coronary flow profiling based on biplane angiograms: influence of geometric simplifications on the three-dimensional reconstruction and wall shear stress calculation  

UK PubMed Central (United Kingdom)

BackgroundClinical studies suggest that local wall shear stress (WSS) patterns modulate the site and the progression of atherosclerotic lesions. Computational fluid dynamics (CFD)...Full Text Available

297

Imaging Response in the Primary Index Lesion and Clinical Outcomes Following Transarterial Locoregional Therapy for Hepatocellular Carcinoma  

UK PubMed Central (United Kingdom)

ContextResponse Evaluation Criteria in Solid Tumors [RECIST (unidimensional)], World Health Organization [WHO (bi-dimensional)] and European Association for Study...Full Text Available

2010-03-17

298

Hemangiopericytomas of the spine: case report and review of the literature  

UK PubMed Central (United Kingdom)

We describe a rare case of a primary intracranial meningeal hemangiopericytoma (HPC) with late metastasis to the cervical spine. A 36-year-old woman had a left occipital lesion that was histopathologically...Full Text Available

299

Genetic Polymorphism of Cancer Susceptibility Genes and HPV Infection in Cervical Carcinogenesis  

UK PubMed Central (United Kingdom)

It is widely accepted that specific human papillomavirus (HPV) types are the central etiologic agent of cervical carcinogenesis. However, a number of infected women do not develop invasive lesions,...Full Text Available

300

Fine Needle Aspiration Cytology of the Breast: The Nonmalignant Categories  

UK PubMed Central (United Kingdom)

Currently, accurate diagnosis of breast lesions depends on a triple assessment approach comprising clinical, imaging and pathologic examinations. Fine needle aspiration cytology (FNAC) is widely adopted...Full Text Available

301

Extraosseous Ewing's sarcoma: review of a case  

International Nuclear Information System (INIS)

Extraosseous Ewing's sarcoma (EES) is an uncommon lesion included in the group of soft tissue tumors. We present a case in a 19-year-old woman in which the diagnosis was not initially suspected because of the absence of clinical and radiological evidence. (Author).

302

Expression of p53 in leukoplakia and squamous cell carcinoma of the oral mucosa: correlation with expression of Ki67  

UK PubMed Central (United Kingdom)

Aim—To study p53 expression in relation to proliferative status in normal and nondysplastic, dysplastic and malignant lesions of the oral mucosa.Method—The...Full Text Available

1996-06-01

303

Evidence for proteolytic cleavage of brevican by the ADAMTSs in the dentate gyrus after excitotoxic lesion of the mouse entorhinal cortex  

UK PubMed Central (United Kingdom)

BackgroundBrevican is a member of the lectican family of aggregating extracellular matrix (ECM) proteoglycans that bear chondroitin sulfate (CS) chains. It is highly expressed in...Full Text Available

304

Evidence for a lack of DNA double-strand break repair in human cells exposed to very low x-ray doses  

UK PubMed Central (United Kingdom)

DNA double-strand breaks (DSBs) are generally accepted to be the most biologically significant lesion by which ionizing radiation causes cancer and hereditary disease. However, no information on the...Full Text Available

2003-04-29

305

Distribution Frequency of Pathogenic Bacteria Isolated from Cutaneus Leishmaniasis Lesions  

UK PubMed Central (United Kingdom)

Cutaneous leishmaniasis (CL) is a parasitic disease characterized by single or multiple ulcerations. Secondary bacterial infections are one of the complications that can increase the tissue destruction...Full Text Available

2008-09-01

306

Dental caries: A complete changeover (Part II)-Changeover in the diagnosis and prognosis  

UK PubMed Central (United Kingdom)

Realization that dental caries is a reversible, dynamic biochemical event at a micron level has changed the way the profession recognizes the caries disease and the caries lesion. The diagnosis of dental...Full Text Available

2009-07-01

307

Cortical auditory disorders: clinical and psychoacoustic features.  

UK PubMed Central (United Kingdom)

The symptoms of two patients with bilateral cortical auditory lesions evolved from cortical deafness to other auditory syndromes: generalised auditory agnosia, amusia and/or pure word deafness, and...Full Text Available

1988-01-01

308

Comparison of injection techniques for shoulder pain: results of a double blind, randomised study.  

UK PubMed Central (United Kingdom)

Seventy seven patients with soft tissue shoulder lesions including adhesive capsulitis and disorders of the rotator cuff and acromioclavicular joint were admitted to a trial comparing two different...Full Text Available

1983-11-05

309

Chondrogenic differentiation potential of osteoarthritic chondrocytes and their possible use in matrix-associated autologous chondrocyte transplantation  

UK PubMed Central (United Kingdom)

IntroductionAutologous chondrocyte transplantation (ACT) is a routine technique to regenerate focal cartilage lesions. However, patients with osteoarthritis (OA) are lacking an appropriate...Full Text Available

2009-01-01

310

Characteristics of common solid liver lesions and recommendations for diagnostic workup  

UK PubMed Central (United Kingdom)

Due to the widespread clinical use of imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available

2009-07-14

311

Angiomatoid giant cellular blue nevus of vaginal wall associated with pregnancy  

UK PubMed Central (United Kingdom)

BackgroundBlue nevi that arise from the Müllerian tract are rare melanocytic lesions. Several histopathologic variants of cellular blue nevi have been described. The angiomatoid...Full Text Available

312

Implementation of Accelerated Beam-Specific Matched-Filter-Based Optical Alignment  

Energy Technology Data Exchange (ETDEWEB)

Accurate automated alignment of laser beams in the National Ignition Facility (NIF) is essential for achieving extreme temperature and pressure required for inertial confinement fusion. The alignment achieved by the integrated control systems relies on algorithms processing video images to determine the position of the laser beam images in real-time. Alignment images that exhibit wide variations in beam quality require a matched-filter algorithm for position detection. One challenge in designing a matched-filter based algorithm is to construct a filter template that is resilient to variations in imaging conditions while guaranteeing accurate position determination. A second challenge is to process the image as fast as possible. This paper describes the development of a new analytical template that captures key recurring features present in the beam image to accurately estimate the beam position under good image quality ...

2009-01-29

313

[Special cases of vascular injuries by war projectiles].  

Science.gov (United States)

The author resumes what is actually known about the behaviour of war projectiles in the target (wound ballistics). This is function of their nature, their velocity, their air trajectory. The difference between lesions due to slow moving bullets and these due to projectiles with a high kinetic energy is outlined. The last ones create, through the temporary cavitation effect, lesions at distance from the residual visible tract, particularly in the vascular conduits. The therapeutic conclusions, which derive from those ballistic behaviours, are briefly described in matter of repair of vascular war injuries [Acta chir. belg., 1982, 82, 457-461]. PMID:7148288

314

Percutaneous US-guided RF thermal ablation for malignant renal tumors: preliminary results in 13 patients  

Energy Technology Data Exchange (ETDEWEB)

Minimally invasive treatment for small renal cell carcinoma (RCC) can be necessary in selected patients and, anyway, is desirable. In situ ablation techniques, including RFA, have been developed. The aim of this study is to evaluate the feasibility, safety and short-term local effectiveness of percutaneous US-guided RFA in a small series, as well as mid-term patient outcome. Thirteen patients with a total of 18 tumors (17 small lesions, 35 mm in size or less, and a larger one, 75 mm in size) underwent 19 RFA sessions. Seven patients had a solitary kidney, and three suffered from VHL disease, too. We treated four lesions in a patient with a bilateral tumor. In another patient, three lesions were ablated. Seventeen tumors were RCC; one was a metastasis from lung cancer. Eight lesions were parenchymal, six exophytic, two parenchymal/exophytic, one parenchymal/central and one central. A monopolar RF system ...

2004-12-01

315

Nodular fasciitis: correlation of MRI findings and histopathology  

Energy Technology Data Exchange (ETDEWEB)

Objective: To compare the histopathology of nodular fasciitis (NF) with the magnetic resonance imaging (MRI) findings in order to evaluate the basis of the MR signal characteristics. Design and patients: Ten patients with NF, nine females and 1 male, with an age ranging from 13 to 58 years (mean 26.8 years) were studied. MRI findings, available in all 10 patients, were compared with the histopathology in nine patients, and an area-to-area comparative study of the whole specimen section histopathology and MRI was performed in two patients. Results: On the basis of an excisional biopsy or resection specimen, the nine lesions were classified into myxoid (n=4), cellular (n=3) and fibrous (n=2) subtypes. Four myxoid lesions with a subcutaneous location showed a homogeneous SI comparable with muscle on T1-weighted images, high SI on T2-weighted images, and had homogeneous enhancement. One cellular lesion presented with ...

2002-03-01

316

Ewing's sarcoma of the humerus mimicking fibrous dysplasia on imaging and biological behavior  

International Nuclear Information System (INIS)

We present the case of a 12-year-old girl who presented with a pathological fracture through a benign-appearing osteolytic lesion that was presumed to represent fibrous dysplasia. The fracture healed, and over the next 2.5 years there was further refracturing and healing with progressive osteolysis. A biopsy was performed and revealed Ewing's sarcoma. The disease was locally controlled by neoadjuvant chemotherapy and radiation therapy. The patient is disease free with excellent function 6 years following the discovery of the lesion. We illustrate and discuss the sequence of events. (orig.)

2005-05-01

317

Computed tomography in the evaluation of 41 cases of Ewing's sarcoma  

International Nuclear Information System (INIS)

Computed tomography (CT) has already proved extremely effective both in cerebral and abdominal pathology. Several recent publications describing first heterogeneous series [1, 2, 7, 11-17], then studies of a single type of lesion [3-6, 8] have illustrated its usefulness in the study of bone lesions. This report deals with 41 cases of Ewing's sarcoma studied by CT at the Institut Gustave Roussy from October 1977 to July 1981, and tries to show both the limitations and indications of this technique for the diagnosis, treatment, and follow-up of Ewing's sarcoma as well as in the diagnosis of any eventual recurrence. (orig.).

318

CT-pathologic correlation of focal area of ground-glass attenuation (GGA) in the peripheral lung  

Energy Technology Data Exchange (ETDEWEB)

We compared the characteristics on thin-section CT images with the histological structure of thirty-four surgically resected peripheral lung lesions 30 mm or less in diameter with a greater than 50% area of GGA on thin-section CT. Pathologically, focal area of GGA corresponded to alveolar replacement growth of tumor or interstitial fibrotic thickening of inflammation. It is considered that determination of the GGA in small peripheral lung lesions on thin-section CT is useful for the diagnosis of early adenocarcinomas. (author)

2001-07-01

319

Replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory  

Energy Technology Data Exchange (ETDEWEB)

The DOE-Idaho Operations Office (DOE-ID) has prepared an environmental assessment (EA) on the replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory at the Idaho National Engineering Laboratory (INEL). The purpose of this project is to replace the existing Health Physics Instrumentation Laboratory (HPIL) with a new facility to provide a safe environment for maintaining and calibrating radiation detection instruments used at the Idaho National Engineering Laboratory. The existing HPIL facility provides portable health physics monitoring instrumentation and direct reading dosimetry procurement, maintenance and calibration of radiation detection instruments, and research and development support-services to the INEL and others. However, the existing facility was not originally designed for laboratory activities and does not provide an adequate, safe environment for calibration activities. The EA examined ...

1995-05-01

320

Final report of the second dye-tracer test at the Chesnut Ridge Security Pits, Y-12 Plant, Oak Ridge, Tennessee  

Energy Technology Data Exchange (ETDEWEB)

Martin Marietta Energy Systems, Inc. (Energy Systems) manages a closed hazardous waste disposal unit, Chestnut Ridge Security Pits (CRSP), in the form of two trenches and several auger-holes, located on top of the eastern portion of Chestnut Ridge at the Department of Energy (DOE) Oak Ridge Y-12 Plant in Tennessee. The groundwater monitoring system for the unit presently consists of a network of upgradient and downgradient monitor wells. To investigate the discharge of groundwater to springs and streams, Energy Systems, through Geraghty and Miller, Inc., conducted an initial dye-tracer study during the driest part of 1990. The dye was detected at some of the monitoring sites, but verification was necessary due to the proximity of some sites to extraneous dye sources. Based on the results of the initial study, Energy Systems recommended to the Tennessee Department of Environment and Conservation (TDEC) in the 1990 Groundwater Quality Assessment ...

1992-11-01

321

Experimental and clinical studies on the usefulness and assessment of the angiographic images processed by a digital radiography system (FCR: Fuji Computed Tomography)  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film arteriogram even with a ...

1989-06-01

322

Experimental and clinical studies on the usefulness and assessment of the angiographic images processed by a digital radiography system (FCR: Fuji Computed Tomography)  

International Nuclear Information System (INIS)

The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film arteriogram even with a ...

1989-01-01

323

Diagnosis of occipital condyle fractures; Diagnostik von Frakturen der Okzipitalkondylen  

Energy Technology Data Exchange (ETDEWEB)

Following the conventional X-ray diagnosis of the skull and upper cervical spine, CT proved to be the primary diagnostic method after a skull and brain injury: For all 4 cases we succeeded in detecting the occipital condyle fracture and in determing its size and location by reconstructions (coronal, sagittal, 3-D). In the case of complex occompanying injuries like soft tissue hematomas (cerebral, in the spinal cord, and the soft tissue of the neck) or for the detection of brain stem contusion, MRT had significant advantages. MRT can offer a higher image quality in soft tissue, especially in the spinal cord and the brain. (orig.) [Deutsch] Im Anschluss an die konventionelle Roentgendiagnostik des Schaedels und der Halswirbelsaeule, erwies sich die Computertomographie als primaer einzusetzendes diagnostisches Verfahren, nach erlittenem Schaedel-Hirn-Trauma. In allen Faellen gelang der exakte Frakturnachweis an den ...

1995-01-01

324

Determination of Cinchona alkaloids and Vitamin B_6 by high-performance liquid chromatography with fluorescence detection  

International Nuclear Information System (INIS)

A simple and specific method has been developed for the simultaneous determination of the four major Cinchona alkaloids and their dihydroderivatives and pyridoxine hydrochloride (Vitamin B_6) by high-performance liquid chromatography (HPLC) with fluorescence detection (#lambda#_e_m=420 nm with #lambda#_e_x=330 nm). The chromatographic separation was performed on a Phenomenex Prodigy ODS column (5 #mu#m, 250 mmx3.2 mm i.d.), recommended for basic compounds, under isocratic reversed-phase conditions. The method allowed a good peak shape and an effective resolution of the tested compounds. The extraction of alkaloids from the Cinchona succirubra bark was carried out in mild and fast conditions (ambient temperature, 20 min) by ultrasonication. The procedure showed to be advantageous respect to a reference method, which involved Soxhlet extraction. The results were compared statistically by means of the Student's t-test and the variance ratio F-test; no significant ...

2004-06-04

325

Acoustic and visual remote sensing of barrels of radioactive waste: Application of civilian and military technology to environmental management of the oceans  

Energy Technology Data Exchange (ETDEWEB)

As part of an ongoing strategic research project to find barrels of radioactive waste off San Francisco, the U.S. Navy (USN), the U.S. Geological Survey (USGS), and the Gulf of the Farallones National Marine Sanctuary (GFNMS) pooled their expertise, resources, and technology to form a partnership to verify new computer enhancement techniques developed for detecting targets the size of 55 gallon barrels on sidescan sonar images. Between 1946 and 1970, approximately 47,800 large barrels and other containers of radioactive waste were dumped in the ocean west of San Francisco; the containers litter an area of the sea floor of at least 1400 km {sup 2} knows as the Farallon Island Radioactive Waste Dump. The exact location of the containers and the potential hazard the containers pose to the environment is unknown. The USGS developed computer techniques and contracted with private industry to enhance sidescan data, collected in cooperation with the GFNMS, to ...

1995-04-01

326

SPIO-enhanced MR angiography for the detection of venous thrombosis in an animal model; SPIO-unterstuetzte MR-Angiographie zur Detektion venoeser Thromben im Tiermodell  

Energy Technology Data Exchange (ETDEWEB)

Purpose: An animal model is used to investigate whether MR angiography combined with super-paramagnetic particles of iron oxide (SPIO) is suitable for detecting thromboses. Methods: 42 rats in groups of 7 each were examined on days 1, 3, 5, 7, 9 and 11, respectively, after mechanical/chemical thrombus induction in a 1.5 Tesla magnet with a FISP sequence (TR/TE/FA 50 ms/6 ms/40 ). Imaging was performed before and up to 90 minutes after intravenous injection of 30 {mu}mol FE/kg BW of the experimental SPIO (hydrodynamic diameter, 34{+-}17 nm LLS; R1 and R2 relaxivity at 0.47 T, 31 and 57 L/(mmol*s)). MIP reconstructions of MR angiographies were submitted to consensus assessment by two examiners using histology as the gold standard. Results: The image quality of MIP reconstructions was rated as good in 38 of 42 cases. With regard to thrombotic vessel occlusion, MR angiography coincided with histology in 17 of 42 cases and differed in 25, lumen ...

1999-03-01

329
330

Network Security Defense Tools  

Science.gov (United States)

Lecturo on Firewalls, VPNs, Intrusion Detection, and filters

2009-02-11

334

Quality assurance requirements for nuclear power plants in Hungary  

International Nuclear Information System (INIS)

In Hungary, legislation for nuclear power plants was developed at the end of the 1970s, among which is the quality assurance code for nuclear power plants. Hungarian practice is presented, including discussion of the requirements for quality assurance, qualification of the suppliers and inspection practices. The general requirements of quality assurance in the course of construction of a nuclear power plant are presented: quality assurance of technological equipment, fuel, electrical equipment, automatic instrumentations, building structures and technology.

335

NOZZLE WEAR DETECTION IN ABRASIVE WATERJET ...  

Science.gov (United States)

... Accession Number : ADD330829. Title : NOZZLE WEAR DETECTION IN ABRASIVE WATERJET CUTTING SYSTEMS,. Corporate Author : ...

1990-03-01

336

Electron-Induced Luminescence and X-Ray Spectrometer (ELXS) System for Life Detection  

Science.gov (United States)

The ELXS concept is a novel, portable, micro-instrument targeted for the detection of mineralogic

2002-01-01

337

Detection of the heavy Higgs boson at [gamma][gamma] colliders  

Energy Technology Data Exchange (ETDEWEB)

We consider the possibility of detecting a heavy Higgs boson ([ital m][sub [ital H

1993-07-01

338

CT assessment of blunt diaphragmatic injuries. A retrospective study on 35 cases; Sensibilita' diagnostica della Tomografia Computerizzata nei traumi chiusi del diaframma. Studio retrospettivo di 35 casi consecutivi  

Energy Technology Data Exchange (ETDEWEB)

Purpose of this work is to evaluate the effectiveness and role of CT in blunt diaphragmatic injuries by reviewing our 8-year experience. It is reviewed the preoperative CT findings of 35 patients with surgically confirmed diaphragmatic rupture. Surgical repair was performed in the acute setting (within 12 hours of trauma) in 22 cases, and late (8 months-5 years) in 13 cases. Twenty-eight patients (80%) were examined with conventional CT and 7 (20%) with Helical CT. Of the 13 patients examined long after trauma, the left hemi diaphragm was ruptured in 12 cases (with visceral herniation in 4), and the right hemi diaphragm in 1, with no herniation. The diaphragmatic rent was found in the dome (15 cases, 43%), muscolotendinous junction (11 cases, 31%), muscular portion (8 cases, 23%), and at the muscular attachments on the ribs (1 case, 3%). As for the site of diaphragmatic injury, CT never depicted the diaphragmatic rent in the dome and at the muscolotendinous junction (74%), not even ...

2000-02-01

339

Single Atom Detection With Optical Cavities  

CERN Document Server

We present a thorough analysis of single atom detection using optical cavities. The large set of parameters that influence the signal-to-noise ratio for cavity detection is considered, with an emphasis on detunings, probe power, cavity finesse and photon detection schemes. Real device operating restrictions for single photon counting modules and standard photodiodes are included in our discussion, with heterodyne detection emerging as the clearly favourable technique, particularly for detuned detection at high power.

2008-01-01

340

Explosives detection: the problem and prospects  

Energy Technology Data Exchange (ETDEWEB)

The history of explosives vapor detection includes almost every detection strategy known to man. Initial attempts to utilize these techniques were dismal failures. However, with the development of the Electron Capture Detector (ECD), the first promising detection of explosives vapors became possible. The present commercial explosives detectors detect the higher vapor pressure materials but not the whole spectrum. This paper describes the basic properties of explosives molecules and our research to utilize these properties for increased detection sensitivity.

1984-01-01

341

Water Quality Criteria | Water Quality Criteria | US EPA  

Science.gov (United States)

for? Learn the Issues Science & Technology Laws & Regulations About EPA Contact Us Water: Water Quality Criteria You are here: Water Science & Technology Surface Water Standards &...

2011-08-28

342

The ECOS-16 questionnaire for the evaluation of health related quality of life in post-menopausal women with osteoporosis  

UK PubMed Central (United Kingdom)

BackgroundThe aim of this study is to validate the questionnaire ECOS-16 (Assessment of health related quality of life in osteoporosis) for the evaluation of health related quality...Full Text Available

343

Report of the Department of Energy, Office of Environmental Management, Quality Assessment Program, inorganic intercomparison study  

Energy Technology Data Exchange (ETDEWEB)

This report presents results from the soil inorganic analysis of the 44th set of environmental quality assessment samples, of the quality assessment program, that were received on or before June 3, 1996. The samples were analyzed for RCRA metals.

1996-07-01

344

Report Central: Quality Reporting Tool in an Electronic Health Record  

UK PubMed Central (United Kingdom)

Quality reporting tools, integrated with ambulatory electronic health records, can help clinicians and administrators understand performance, manage populations, and improve quality. Report Central...Full Text Available

2006-01-01

345

Quality measurement and control in physician decision making: state of the art.  

UK PubMed Central (United Kingdom)

The status of the concept of controlling the quality of physicians is reviewed as are studies that have been done on methods to measure and improve quality. The conclusions are dismal given the rhetoric...Full Text Available

1982-01-01

346

Staging of osteochondritis dissecans of the knee and ankle with MRI. Comparison with conventional radiography and arthroscopy; Die Stadienbestimmung der Osteochondrosis dissecans am Knie- und Sprunggelenk mit der MRT. Vergleich mit konventioneller Radiologie und Arthroskopie  

Energy Technology Data Exchange (ETDEWEB)

A prospective study was performed on 50 patients suffering from osteochondritis dissecans of the knee and ankle to define criteria for stability and fixation of osteochondral lesions. Morphological parameters in MRI (size, fragmentation, cartilage, interface) and conventional radiology (separation, fragmentation) were registered and compared with arthroscopical staging. MRI staging based on different types of interfaces was demonstrated on T{sub 1}- and T{sub 2}-weighted images. MRI could correctly predict a Grade 1 lesion in 50%, a Grade 2 lesion in 90%, a Grade 3 lesion on 0%, and a Grade 4 lesion in 79%. Stable lesions were differentiated from unstable lesions in 90%. Radiographic findings corresponded with arthroscopic staging in only 56% of the cases because fibrotic connection may guarantee stability in case of bony separation. ...

1995-07-01

347

`Procurement quality engineering`: A measurement driven system to assure quality at each step in the procurement process  

Energy Technology Data Exchange (ETDEWEB)

The `Procurement Quality Function` is an element of the Body of Knowledge of Quality Engineering, as defined by the American Society for Quality Control (ASQC). This paper describes the Procurement Quality function which has been installed as an integral part of the Quality Engineering group of the Technical and Management Support Services (T&MSS) contractor to the United States Department of Energy (DOE) Yucca Mountain Site Characterization Project. Each of the elements of the T&MSS Procurement Quality Engineering (PQE) system is discussed along with the measurements obtained. With the installation and development of the PQE system we have attained more meaningful evaluation of supplier capability, reduction of procurement document review reject ratios from 31% to less than 2% per quarter, more effective measurement and control of supplier performance, ...

1993-12-31

348

Wind Tunnel Flow Quality and Data Accuracy Requirements  

Science.gov (United States)

... tests, one often encounters, for instance, separated flows with large ... It is suspected that the flow-quality criteria given in AGARD Report No. ...

1982-11-01

349

The quality of hospital records of urethral catheterisation.  

UK PubMed Central (United Kingdom)

BACKGROUND: This prospective and retrospective study carried out over a period of one month (50 patients) looked at the quality of hospital records of urethral catheterisation with reference to the...Full Text Available

2002-03-01

350

The need for water quality criteria for frogs.  

UK PubMed Central (United Kingdom)

Amphibians are considered reliable indicators of environmental quality. In the western United States, a general decline of frog populations parallels an apparent worldwide decline. The factors thought...Full Text Available

1995-04-01

351

Read Code Quality Assurance  

UK PubMed Central (United Kingdom)

As controlled clinical vocabularies assume an increasing role in modern clinical information systems, so the issue of their quality demands greater attention. In order to meet the resulting stringent...Full Text Available

1998-07-01

352

Quantitative and qualitative aspects of agricultural products  

International Nuclear Information System (INIS)

The following aspects will be discussed: The main function of the Division of Inspection Services and its role in the Marketing of agricultural products; the shelf life of agricultural products: short review of present methods with a practical example of losses incurred due to limited keeping quality; irradiation and heat treatment: advantages of inhibited microbiological activities and undesirable chemical changes from a quality control point of view; quality standards: the basic principles of quality control; consequences of effective post-harvest treatment: export of deciduous and citrus fruit; the magnitude of the problem of poor keeping quality and quality requirements; other fruit; quantities and export limitations and vegetables; quantity and quality requirements; local marketing: fruit and vegetables subjected to inspection; quantity ...

353

NAME=\\  

Wastenet

...Air Quality Monitoring Networks Products and Equipment Find and compare a variety of air quality monitoring networks products and equipment on the world's largest environmental industry portal. ...

354

The role of the HCR system in the repair of lethal lesions of Bacillus subtilis phages and their transfecting DNA damaged by radiation and alkylating agents  

International Nuclear Information System (INIS)

The role of the HCR system in the repair of prelethal lesions induced by UV light, #gamma# radiation and alkylating agents was studied in the Bacillus subtilis SPP1 phage, its heat sensitive mutants (N3, N73 nad ts_1) and corresponding infectious DNA. The survival of phages and their transfecting DNA after treatment with UV light is substantially higher in hcr"+ cells than in hcr cells, the differences being more striking in intact phages than in their transfecting DNA's. Repair inhibitors reduce survival in hcr"+ cells: caffeine lowers the survival of UV-irradiated phage SPP1 in exponentially growing hcr"+ cells but has no effect on its survival in competent hcr"+ cells; acriflavin and ethidium bromide decrease the survival of the UV-irradiated SPP1 phage in both exponentially growing and competent hcr"+ cells to the level of survival observed in hcr cells; moreover, ethidium bromide lowers the number of infective centres in hcr"+ cells of the UV-irradiated DNA of ...

355

Clinical studies on cancer of the tongue  

Energy Technology Data Exchange (ETDEWEB)

Thirty-nine previously untreated patients with squamous cell carcinoma of the tongue were treated by irradiation or a combination of irradiation and surgery, with or without chemotherapy, between January 1971 and December 1980. All of the patients had a follow-up period of at least nine years. Twenty-two patients were men and 17 were women. The average age was 50.1 years, with a range of 30 to 74 years. The absolute five-year survival rate was 82.1% and the cumulative ten-year survival rate 76.9% for these 39 patients. Cervical node metastases were clinically found on admission in 14 patients whose five-year survival rate was 64.3%, whereas it was 92.0% for 25 patients without metastasis. The absolute five-year survival rate decreased from 92.3% for patients with stage I lesions to 90.9%, 87.5% and 42.9% for those with stage II, stage III and stage IV lesions, respectively. Most of the patients received external irradiation and intraoral ...

1990-12-01

356

Determination of As, Cd, Pb, and Hg in urine using inductively coupled plasma mass spectrometry with the direct injection high efficiency nebulizer  

Energy Technology Data Exchange (ETDEWEB)

The application of the large-bore direct injection high efficiency nebulizer (LB-DIHEN) for the determination of arsenic (As), cadmium (Cd), lead (Pb), and mercury (Hg) in urine by inductively coupled plasma mass spectrometry (ICP-MS) is described. The LB-DIHEN is compared with the standard method using a concentric pneumatic nebulizer and cyclonic spray chamber. In addition to the toxicological significance of As, Cd, Pb, and Hg, these elements represent a cross-section of analytical issues including spectral interferences (e.g., {sup 40}Ar{sup 35}Cl{sup +} on {sup 75}As{sup +} and {sup 98}Mo{sup 16}O{sup +} on {sup 114}Cd{sup +}) and memory effects (Hg). In this study, the low sample consumption of the LB-DIHEN is used to reduce the volume of urine needed for analysis, and to reduce the volume of final diluted sample required for analysis. Eliminating the spray chamber and reducing the dead volume of the nebulizer reduces memory effects, especially for analytes such as Hg. The ...

2008-03-15

357

Ruthenium-106 brachytherapy for uveal melanomas. Preliminary results: a single institutional experience; Braquiterapia com rutenio-106 em melanomas uveais. Resultados preliminares: experiencia uni-instuticional  

Energy Technology Data Exchange (ETDEWEB)

Objective: To analyze the early response of uveal melanomas in patients treated with ruthenium-106 brachytherapy. Materials And Methods: In the period between April 2002 and July 2003, 20 patients diagnosed with uveal melanoma were submitted to ruthenium-106 brachytherapy. The calculated dose delivered at the apex of the tumor ranged between 55 Gy and 100 Gy. Patients with lesions greater than 5 mm were submitted to transpupillary thermotherapy concomitantly with ophthalmic plaque insertion. Results: As regards the lesions site, 75% of the lesions were located in the choroid, 15% in the iris, and the remainder 10% in the ciliary body. In a median 19-month-follow-up, the progression-free survival for brachytherapy was 69%, and 87% for associated brachytherapy and transpupillary thermotherapy. A significant tumor height reduction was observed after treatment. No patient was submitted to enucleation. Conclusion: Our ...

2007-03-15

358

Radiofrequency ablation of lung and liver lesions using CT fluoroscopy  

International Nuclear Information System (INIS)

Full text: Tumour ablation with radiofrequency (RF) energy is a relatively new procedure for the treatment of focal malignant disease. At our institution this is currently being used in the treatment of certain liver and lung lesions with the patients involved being enrolled in clinical trials. The poster describes the technique used at our institution for the placement of the radiofrequency ablation electrode using CT fluoroscopy. Criteria for patient selection are included. Complications from the procedure are described, as well as follow up appearances and results. Our results from the treatment of primary and secondary lesions in the liver correlate well with published literature. Treatment is still not as successful as surgical resection but there is significantly less morbidity. Where this method may be appropriate is when the patient is not a candidate for surgical resection. The treatment of colorectal metastases in the lung shows early ...

2002-06-01

359

Macromodular splenic tuberculosis in a medically-treated AIDS patient: diagnosis and management by CT  

International Nuclear Information System (INIS)

We used computerized tomography (CT) in the study of eight patients with macronodular splenic tuberculosis prior to the microbiological diagnosis. These patients underwent additional CT controls during and after tuberculostatic therapy. All the patients studed presented the acquired immunodeficiency syndrome (AIDS). Splenomegaly and numerosous round, hypodense lesions that showed no contrast uptake were found in all the subjects. Only three patients presented evidence of tuberculosis in plain radiography and/or chest X-ray. Two patients presented abdominal lymph nodes. None of them showed evidence of hepatic lesions or ascites. follow-up CT scans revealed a progressive reduction of the lesions, which eventually disappeared completely, and splenomegaly was considerably reduced. Anthough it is uncommon, we should suspect splenic involvement in tuberculosis if the clinical and radiological contexts are appropriate. CT provides ...

360

Localization of islet cell tumors by dynamic CT: comparison with plain CT, arteriography, sonography, and venous sampling  

Energy Technology Data Exchange (ETDEWEB)

Ten patients with suspected islet cell tumors (seven with possible gastrinomas, three with insulinomas) underwent diagnostic evaluation with dynamic CT scanning, routine CT scanning, angiography, and sonography. Venous sampling was also performed in selected instances. Nine sites of gastrinoma and three insulinomas were confirmed surgically in eight patients. Two patients had negative surgical explorations. Routine CT demonstrated five of the nine gastrinomas and one of two insulinomas. Angiography was positive in six of nine gastrinomas and all three insulinomas. Sonography showed only two of the nine gastrinomas and two of the three insulinomas. Dynamic CT scanning demonstrated three additional lesions (two gastrinomas, on insulinoma) not visible on routine CT scanning. Although most of these lesions were visible arteriographically, dynamic CT scans at the appropriate level localized the pathology in the transverse plane and greatly aided in ...

1984-09-01

361

Incidental brain lesions on MRI in the depressive elderly  

Energy Technology Data Exchange (ETDEWEB)

The study was designed to determine the correlation between parenchymal lesions on MRI and depression. Thirty patients with depression satisfying the following criteria were selected: (1) 60 years or over at the time of MRI scanning, (2) no evidence of cerebrovascular disorder or dementia, and (3) no evidence of neurological findings such as extremity palsy. Seventy six patients with no history of psychiatric visits to a clinic served as controls. There was no significant difference in risk factors for cerebrovascular disorders, such as hypertension, diabetes mellitus, and ischemic heart disease, between the depressive group and the control group. MRI manifestations were semiquantitatively scored according to the periventricular hyperintensity (PVH), white matter hyperintensity (WMH), and pons hyperintensity (PH). All of the PVH score, WMH score, and cerebral enlargement index correlated with age. Although there was no significant difference in the incidence of ...

1994-07-01

362

High resolution computed tomography in the study of cervical spine trauma  

International Nuclear Information System (INIS)

Correct ortopedic therapy for traumas of the cervical rachis requires perfect knowledge of the spatial balance of the fracture focus. The authors belive Computed Tomography (CT) to be the most suitable, and often indispensable, method for this purpose. Twenty-four patients were examined for traumatic pathology of the cervical rachis. In 7 cases with clinically minor traumas, the negative outcome of the traditional traumas, the negative outcome of the traditional exam was considered reliable and sufficient for therapeutic purposes. The extant 17 patients were examined also by means of CT, either to better dermine the characteristics of skeletal lesions already ascertained with traditional techniques or to asses the presence of clinically-suspected osteo-articular lesions, even with negative conventional X-rays. For 9 of these patients orthopedic treatment was considered sufficient, whereas 8 patients underwent surgery and were subsequently ...

1989-01-01

363

Focal lesions in external auditory canal: computed tomography images  

International Nuclear Information System (INIS)

To analyze and review the most common focal lesions of the external auditory canal (EAC), describing the computed tomography (CT) findings. The CT images of EAC were reviewed in a series of 167 patients. Abnormal findings were recorded in 13 cases. The CT images were correlated with otoscopic and/or intraoperative findings. There were four cases of osteoma (one located outside the EAC); all of which were treated surgically, as was the one case of exostosis. Six patients presented debris in EAC, coinciding with clinical evidence of external otitis. There were two cholesteatomas derived from EAC, one of them secondary to survery to treat osteoma. On patient was diagnosed as having a basal cell carcinoma of the ear, extending to EAC, but refused to undergo surgery. Five patients presented small triangular laminae of dense bone arising from the upper wall of the EAC which were defined as abnormal variants of the fusion of the temporal squamous epithelium to the ...

364

Diagnosis for the cancer extension of cholangiocarcinoma. The current status  

International Nuclear Information System (INIS)

Described is the diagnosis for the cancer extension of cholangiocarcinoma by various imaging techniques and processes to support the current surgical procedure based on preoperative biliary drainage. The cancer tends to locally extend horizontally and/or vertically and its diagnosis is important for surgical indication. For the indication, multi-detector raw CT (MDCT) and MR cholangio-pancreatography (MRCP) are useful and particularly, the former can give multi-phase (arterial, portal and delayed) images to reconstruct multiplanar (MPR) and CT angiographic 3D images, which have made the previous invasive examinations like angiography and percutaneous transportal contrasting unnecessary. MDCT and MRCP can almost complete the diagnosis of the extension. The operative procedure is decided dependently on the site of the lesion, and of which diagnosis, whether it is hepatic hilar/on upper bile duct or middle/lower ductal, is different. MDCT-MPR and MRCP are virtually ...

2010-07-01

366

Winter Air Quality Study  

Science.gov (United States)

... 15 minutes Time lapse video Time Lapse Recorder (Panasonic) SVHS 4-seconds

368

Quality assurance requirements in various codes and standards  

International Nuclear Information System (INIS)

The quality assurance requirements in various countries and according to various international codes and standards are presented, compared and critically discussed. Cases of developing countries are also discussed, and the use of IAEA code of practice and other codes for quality assurance in these countries is reviewed. Recommendations are made regarding the quality assurance system to be applied for Egypt's nuclear power plants.

369

Quality assurance requirements in nuclear systems  

International Nuclear Information System (INIS)

(1974). United States Lingafelter, JW Nuclear Services Corp., Campbell, CA

1974-09-23

371

Quality assurance during operation of nuclear power plants  

International Nuclear Information System (INIS)

The general requirements applicable to the quality assurance of the Finnish nuclear power plants are presented in the Council of State Decision (395/91) and in the guide YVL 1.4. This guide specifies the quality assurance requirements to be applied during the operation of the nuclear power plants as well as of the other nuclear facilities. Quality assurance applies to all the activities and organizations with a bearing on the safe operation of the nuclear power plants. (5 refs.).

381

FFTF driver fuel pellets: typical pellet lot data  

Science.gov (United States)

Quality assurance data for FFTF reactor fuel pellets are presented.

390

Demands on quality assurance in operation  

International Nuclear Information System (INIS)

The present code requirements on quality assurance as well as the present praxice of quality assurance procedures in the operation of nuclear power plants are presented. On the example of recurring inspections the organizational and technical complications are shown with respect to the code and licensing requirements. Taking the present experiences into account suggestions are given how to transform the general requirements of KTA 1401 to quality assurance requirements during plant operation. (orig.).

1981-03-01

393

Application of dose factors for decay chains  

International Nuclear Information System (INIS)

... dose rates inhalation iodine 134 krypton 88 nuclear decay quality factor

398

 

UK PubMed Central (United Kingdom)

Health surveillance program This article outlines the principal components of quality control of laboratory rodents.

1986-02-01

399

Fuzzy theory applied in quality management of distributed manufacturing system: A literature review and classification  

British Library Electronic Table of Contents (United Kingdom)

Fuzzy theory has been regarded as a very important technique for quality management (QM) of distributed manufacturing system and attracts the attentions of academic and industry; however, there is a lack of a comprehensive literature review and a classification scheme for it. This paper is the first academic literature review of the fuzzy theory applied in quality management of distributed manufacturing system. It involves five most popular databases in this research area and covers more than 20 journals, proposes a classification scheme using clustering analysis method. Sixty-one journal articles were finally selected, reviewed and classified. Each selected article was classified firstly based on four QM dimensions (quality planning, quality control, quality assurance and quality improvem...

2011-01-01

400

External quality control for immunocytochemistry on cytology samples: a review of UK NEQAS ICC (cytology module) results  

British Library Electronic Table of Contents (United Kingdom)

I. S. Kirbis, P. Maxwell, M. S. Flear, K. Miller and M. Ibrahim External quality control for immunocytochemistry on cytology samples: a review of UK NEQAS ICC (cytology module) results Objective:- To date, external quality control for immunocytochemistry on cytology samples is provided only by the United Kingdom national external quality assessment service for immunocytochemistry and in situ hybridisation (UK NEQAS ICC & ISH). For the purpose of this study a retrospective analysis of a comprehensive collection of quality-related data regarding immunocytochemistry on cytology samples collected through this service was analysed. Methods:- The quality of immunocytochemical reactions, using on-line collected data, was analysed for the last 23 UK NEQAS ICC cytology module external quality asses...

2011-01-01

401

Does superior firm performance lead to higher quality outside directorships?  

British Library Electronic Table of Contents (United Kingdom)

Purpose - Holding the number of outside directorships constant, this paper aims to test whether executive directors from superior performing firms are subsequently rewarded with better quality outside directorships. Design/methodology/approach - The quality of new outside directorship appointments is modelled using a two-step Heckman selection procedure to control for the probability of acquiring a new outside board seat. Outside directorship quality is estimated using an index formed from series of observable firm-specific characteristics proxying for the following three latent aspects of quality: prestige, reputational risk and monetary rewards. The index aggregates across these three dimensions to produce an overall quality score, with higher scores signifying higher quality directorshi...

2008-01-01

402

Diagnostic quality in hysterosalpingography  

International Nuclear Information System (INIS)

Purpose: To compare the diagnostic quality and adverse events of the water-soluble, non-ionic, iso-osmolar, dimeric contrast media iodixanol and iotrolan in hysterosalpingography (HSG). Material and Methods: One hundred and twenty patients participated in a double-blind randomized parallel-group phase-III study. Questionnaires and patient interviews were used. Diagnostic quality was assessed using a visual analogue scale and the quality in specific regions was rated using a categorical scale. Results: Overall diagnostic quality was equal for the two groups. There was no statistically significant difference between the two groups in diagnostic quality in the specific regions of interest. No differences between the contrast media were found with regard to adverse events. Conclusion: Both contrast media provided images of high diagnostic quality in HSG. (orig.)

1998-11-01

403

Tumour affinity of [sup 203]Pb-chloride: comparison with [sup 67]Ga-citrate and [sup 201]Tl-chloride  

Energy Technology Data Exchange (ETDEWEB)

[sup 203]Pb-chloride is a promising imaging agent for tumour scanning because of the large retention value for tumour tissue and the small value for normal organs, but the large value for the kidneys and bone is a shortcoming. The retention value of [sup 203]Pb in tumour tissue is larger than that of [sup 201]Tl and smaller than that of [sup 67]Ga. The tumour/inflammatory lesion retention ratio for [sup 203]Pb is very large in comparison with those for [sup 67]Ga and [sup 201]Tl. [sup 203]Pb accumulates to a large extent in viable tumour tissue, and less in necrotic tumour tissue and in inflammatory lesion. (author).

1994-01-01

404

Treatment of asymptomatic internal resorption of a maxillary premolar tooth in a military working dog.  

Science.gov (United States)

An asymptomatic pink discoloration of a maxillary right fourth premolar tooth was discovered during a routine oral examination on a 9 year-old Belgian Malinois dog. A radiolucent lesion was seen in the pulpal chamber on radiographic examination. The lesion had perforated the mesiobuccal root of the tooth. The primary differential diagnosis was idiopathic internal resorption. The tooth was treated by partial resection (removal of the mesiobuccal root and associated crown). A vital pulpotomy and amalgam restoration was performed on the remaining tooth structure. A follow-up 1 year later demonstrated a successful treatment outcome. The animal was asymptomatic and able to perform military duties. Clinical and radiographic signs of healing were evident and the tooth was functional. PMID:10518874

1998-12-01

405

The Adrenal Mass: Correlation of Histopathology with Imaging  

British Library Electronic Table of Contents (United Kingdom)

Background Computed tomography (CT) and magnetic resonance (MR) imaging can help diagnose benign adrenal adenomas, but prior studies rely on nonoperative follow-up as proof of a lesion?s benign nature. We examined adrenalectomy tissues to determine if imaging characteristics correlate with histopathologic findings. Methods We retrieved data for 196 consecutive adrenalectomies in 192 patients from 2000 to 2008. Imaging results were considered to signify benign adrenal adenoma if one or more of the following was present: Hounsfield units 60% or relative contrast washout of >40%, or MR with chemical-shift imaging demonstrating loss of signal intensity on out-of-phase images. Results The sensitivity and specif...

2010-01-01

406

Sialography, echography and computed tomography in parotid gland study  

International Nuclear Information System (INIS)

The diagnostic accuracy of sialography and ultrasonography (US) in the evaluation of parotid masses is evaluated. Furthermore the role of computed tomography (CT) in this pathology is discussed. In the personal experience US proved to be the best method in the recognition of a parotid tumor while sialography was superior in defining the intra or extraparotid site. The two investigations showed the same accuracy in the definition of benign or malignant nature of the mass. Therefore we consider US the only investigation in most istances; sialography could be performed when the site of the lesion is uncertain or an inflammatory lesion is suspected. CT is never the first investigation; its use is limited to a low number of cases, mainly for the evaluation of large masses and when the association US-sialography does not allow a sure diagnosis.

1985-01-01

407

Report on NCI symposium: comparison of mechanisms of carcinogenesis by radiation and chemical agents. II. Cellular and animal models  

International Nuclear Information System (INIS)

The point at which the common final pathway for induction of cancer by chemical carcinogens and ionizing radiation has not been identified. Although common molecular targets are suggested by recent findings about the role of oncogenes, the mechanism by which the deposition of radiation energy and the formation of adducts or other DNA lesions induced by chemicals affects the changes in the relevant targets may be quite different. The damage to DNA that plays no part in the transformation events, but that influences the stability of the genome, and therefore, the probability of subsequent changes that influence tumorigenesis may be more readily induced by some agents than others. Similarly, the degree of cytotoxic effects that disrupt tissue integrity and increase the probability of expression of initiated cells may be dependent on the type of carcinogen. Also, evidence was presented that repair of the initial lesions could be demonstrated after ...

1984-05-20

408

Radiographic features of Ewing's sarcoma of the bones of the hands and feet  

International Nuclear Information System (INIS)

The radiographic features of Ewing's sarcoma of the bones of the hands and feet are reviewed utilizing cases obtained from the Mayo Clinic patient files and the consultation files of Drs. D.C. Dahlin and K.K. Unni. This series consists of a total of 43 cases of pathologically proven Ewing's sarcoma involving the small bones of the hands and feet. The classic radiographic features of Ewing's sarcoma in the long bones, including lytic, permeative destruction, aggressive periosteal reaction, cortical violation, and a soft tissue mass, are also seen in the bones of the hands and feet, with similar frequency. These classic features are most commonly present in lesions affecting the short tubular bones. Lesions affecting the tarsal bones more often demonstrate atypical radiographic features. These atypical radiographic appearances may play a role in the reported delay in diagnosis of Ewing's sarcoma within the tarsal bones. (orig.)

2001-03-01

409

MRI in definition of bleeding source, lesion pattern and therapy in haemarthros of the knee; Die MRT beim Haemarthros des Kniegelenks: Bestimmung von Blutungsursachen, Verletzungsmustern und Therapie  

Energy Technology Data Exchange (ETDEWEB)

Patients with haemarthros of the knee were examined by MRI and arthroscopy to identify the bleeding source and to determine surgical or conservative therapy. A prospective study was performed on 120 patients who underwent MRI and arthroscopy, point lesions and bleeding sources were documented separately on a standardised form. Arthroscopy demonstrated a ruptured anterior cruciate ligament in 86%, meniscal tears in 55%, disruption of collateral ligaments in 17%, osteochondral lesions in 5% and tears of capsule or plicae in 13%. Disruption of cruciate ligaments caused haemorrhage in all but three cases. In contrast, only meniscal tears located very adjacent to the meniscal basement had bled. Those types of osteochondral lesions caused haemorrhage characterised on MRI by destruction of the subchondral plate and overlying cartilage. Severe lesions of the knee were diagnosed by MRI in 71% to 100%, slight ...

1996-09-01

410

Local control of Ewing's sarcoma: an analysis of 67 patients  

International Nuclear Information System (INIS)

Local control of Ewing's sarcoma was analysed in a series of 67 patients treated by surgery and/or radiotherapy as well as combination chemotherapy. Radiotherapy was employed with or without surgery in 60 patients and produced an overall local control rate of 55%; complete excision of the primary lesion seemed to be beneficial. There was a marked variation in control rates depending on the site of the primary lesion: limb 85%, rib 53%, pelvis 31% and other sites 33%.Primary tumours greater than 10 cm in diameter were significantly less likely to be controlled. Using daily fractions of approximately 180 cGy, total doses in excess of 6000 cGy seem more likely to produce serious late morbidity amd may not increase the local control rate. No cases of second malignancy arising in irradiated tissue have been observed to date, but one patient developed acute lymphoblastic leukaemia. (author).

411

Large (≥2cm) non-hypervascular nodules depicted on MRI in the cirrhotic liver: fate and implications  

British Library Electronic Table of Contents (United Kingdom)

Aim To determine the fate and clinical implication of large (?2cm), non-hypervascular nodules depicted on magnetic resonance imaging (MRI) in the cirrhotic liver. Materials and methods In 21 patients with cirrhosis (14 hepatitis B, two ethanol abuse, four cryptogenic, one Wilson's disease), 25 large (?2cm in the longest dimension) non-hypervascular nodules were identified on dynamic MRI. The implications for diagnosis of the initial size, contour, and signal characteristics on MRI in addition to patients' age and cause of cirrhosis were assessed in our analysis. Results Twelve (75%) out of 16 lesions were malignant or potentially-malignant from 14 hepatitis B patients, while seven (78%) of the nine lesions from other patients were benign (p=0.016). The mean age of the patients who ha...

2008-01-01

412

Lacrimal gland masses on CT and MRI: a report of four cases  

International Nuclear Information System (INIS)

In an extended case report, we discuss four cases with masses in the lacrimal fossa representing the most important entities in this region (lymphoma, pleomorphadenoma, inflammatory pseudotumor, and malignant epithelial tumor). The different indications for CT and MRI are explained. For the differential diagnosis of lacrimal gland lesions, the following imaging parameters are important: The shape of the lacrimal gland, the inner structure, the degree of contrast enhancement, and the surrounding bony structures. In the evaluation of the expansion of lacrimal gland lesions, CT in thin slices with multiplanar reconstructions is equal to MRI. However, the contrast-enhancement of lacrimal glands is better evaluated with MRI than with CT. The bony structures are better visualized on CT than on MRI. (orig.).

413

Integrated Coronary Physiology in Percutaneous Intervention: A new paradigm in interventional cardiology  

British Library Electronic Table of Contents (United Kingdom)

Coronary angiography has provided an unrivalled appreciation of coronary anatomy fostering a far greater appreciation of the extent of atherosclerotic disease. However, the subjectivity of coronary angiography at determining the extent of plaque has been exposed with IVUS. Indices of coronary physiology have provided valuable adjunctive information as to the physiological importance of specific lesions. Fractional flow reserve is an established method for evaluating the significance of epicardial stenoses. Fractional flow reserve guided percutaneous coronary intervention is associated with improved outcomes when compared to a conventional angiographic guided strategy, particularly in intermediate lesions. The use of coronary physiology in the cath lab represents a new avenue to guide appro...

2011-01-01

414

Follow-up and diagnosis of recurrences after radio-chemotherapy of malignant head and neck tumors  

International Nuclear Information System (INIS)

339 CT und 95 MRT examinations in 210 partients were evaluated retrospectively to determine the value of CT and MRT for follow-up of head and neck tumors and for diagnosing recurrences. Semi-quantitative evaluation of tumor extent during and after radiotherapy showed advantages for MRT since changes induced by treatment, particularly oedema, produced less contrast loss in the images. CT had a sensitivity of 81% for the recognition of recurrences; this was 92% for MRT. Specificity for CT was 76% and for MRT 86%. Concerning the reliability of individual diagnostic criteria, space occupying lesions were the most valuable in CT diagnosis. For MRT, space occupying lesions and infiltration into neighbouring structures were of equal value. Because of differences in the nature of the signals, MRT proved better than CT in characterising recurrent masses and this improved the differentiation between scarring and local tumour recurrence. (orig.).

415

Fifteen-year follow-up of a patient with beta thalassaemia and extramedullary haematopoietic tissue compressing the spinal cord  

Energy Technology Data Exchange (ETDEWEB)

A long-term follow-up of a patient with beta thalassaemia with intra- and extraspinal extramedullary haematopoietic tissue compressing the spinal cord is presented. Extramedullary haematopoietic nodules are a rare cause of spinal cord compression and should be included in the differential diagnosis, especially in patients from Mediterranean countries. Treatment with radiation therapy solely failed, giving rise to the need of surgical intervention. Surgical decompression of the spine and the removal of the culprit lesion compressing the spine were performed. Postinterventional radiation therapy was applied to the spine. A relapse had to be treated again by surgical means combined with postinterventional radiation therapy. A complete relief of the symptoms and control of the lesion could be obtained.

2005-04-01

416

A case of subfascial lipoma in the lateral space of neck: US and CT findings  

British Library Electronic Table of Contents (United Kingdom)

Sommario I lipomi del collo e della testa in genere si verificano nel tessuto sottocutaneo superficiale. Quelli sottofasciali intramuscolari sono molto rari. Riportiamo di seguito il caso di una donna di 53 anni con un lipoma sottofasciale localizzato nello spazio antero-laterale del collo. La diagnosi della lesione e stata ottenuta con esame clinico e confermata con Ecografia (US) e Tomografia Computerizzata (TC). La lesione, caratterizzata da capsula e aspetto fibrolipomatoso, e stata escissa con intervento chirurgico.

2009-01-01

417

High quality water supply system; Joshitsusui kyokyu system  

Energy Technology Data Exchange (ETDEWEB)

This paper, firstly, introduces the background in developing a high quality water supply system, in which the drinking water system is isolated inside a building. Results of questionnaire on the high quality service water are illustrated. The results of questionnaire have revealed that the high quality service water is extremely interested. Then, are described the target quality of high quality water, the constitution of high quality water supply system, the treatment process, the measures to secure safety and sanitary, and the method of maintenance. The high quality water is produced through the activated charcoal absorption treatment, membrane treatment, ozonation, cooling, mineral addition, and disinfection of city water. Furthermore, application examples of this system adopted to a department store and a bachelor apartment house are ...

1995-01-15

418

Development of radioimmunometric assays and kits for non-clinical applications. Proceedings of a final research coordination meeting  

International Nuclear Information System (INIS)

Immunoassays are versatile analytical techniques that had a leading role in various clinical applications, during the last four decades. The studies carried out by Rosalyn Yalow, Solomon Berson and Roger Ekins in the 1960s gave a breakthrough in the development of this novel analytical method. Sensitivity up to femtomolar concentrations, high specificity and universal application to different classes of molecular species made immunoassay a very useful tool in analytical investigation. The expertise acquired by immunochemists in producing antibodies against any antigen and the ability of radiochemists in labeling the antigens with "1"2"5I without affecting the active site are the two main factors responsible for the above development. There are concerns about the safety and health of humans due to the high-level contamination of environment by pesticides, industrial compounds and metals, anabolic steroids in milk and meat products, and presence of mycotoxins in food and feed ...

2004-12-06

419

How to start a utility TQM program  

Energy Technology Data Exchange (ETDEWEB)

Huntsville, Alabama Utilities has successfully provided services for over 53 years. However, the quality of service demands from customers are changing every day! Part of this demand is due to updated digital appliances, home and business computers, and automated systems. A quality program was initiated in 1992 as a result of an internal assessment. The Malcolm Baldrige approach was selected which includes seven areas: (1) Leadership; (2) Information and Analysis; (3) Strategic Planning; (4) Human Resource Utilization; (5) Quality Assurance of Products and Services: (6) Quality Results: (7) Customer Satisfaction. Training for and implementation of the Quality program is discussed in detail.

1994-12-31

420

Brand-specific tastes for quality  

British Library Electronic Table of Contents (United Kingdom)

This paper develops a model of nonlinear pricing with competition. The novel element is that each consumer's willingness to pay for quality is private information and is allowed to differ across brands. The consumer's preferences are represented by a multidimensional type containing the marginal value of quality for different products. Buyers with high willingness to pay for quality also display strong preferences for particular brands, and require higher discounts in order to switch away from their favorite product. Therefore, competition is fiercer for buyers with lower tastes for quality, and hence more elastic demands. This is in sharp contrast to earlier models in which competition is fiercer for higher-taste, more valuable buyers. In equilibrium, firms either compete intensively for ...

2011-01-01

421

Amazon.com: The Art of Application Performance Testing: Help for Programmers and Quality Assurance (9780596520663): Ian Molyneaux: Books  

Wastenet

...com: The Art of Application Performance Testing : Help for Programmers and Quality Assurance (9780596520663): Ian Molyneaux: Books Amazon.com:...The Art of Application Performance Testing : Help for Programmers and Quality Assurance (9780596520663): Ian Molyneaux: Books Ian Molyneaux,The ...Art of Application Performance Testing : Help for Programmers and Quality Assurance,O'Reilly Media,0596520662,LA9780596520663,Computer Books: General,Application software,Computer software,...com: The Art of Application Performance Testing : Help for Programmers and Quality Assurance (9780596520663): Ian Molyneaux: Books ...

422

The Detection of Pressure Fluctuations, Sonic Audition, Is the Dominant Mode of Dipole-Source Detection in Goldfish (Carassius auratus)  

UK PubMed Central (United Kingdom)

Behavioral detection of a low-frequency (40 Hz) vibratory dipole at source distances of 1.5–24 cm was measured by classically conditioned respiratory suppression in goldfish (Carassius...Full Text Available

2009-04-01

423

Early detection of bone metastases of Ewing's sarcoma by magnetic resonance imaging  

International Nuclear Information System (INIS)

Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).

424

Detection and Toxin Typing of Clostridium perfringens in Formalin-Fixed, Paraffin-Embedded Tissue Samples by PCR?  

UK PubMed Central (United Kingdom)

Since current microbiology methods are not suitable to detect Clostridium perfringens in formalin-fixed, paraffin-embedded tissue samples, we developed a PCR assay to detect toxin-encoding...Full Text Available

2009-03-01

425

Detection and Identification of Ciprofloxacin-Resistant Yersinia pestis by Denaturing High-Performance Liquid Chromatography  

UK PubMed Central (United Kingdom)

Denaturing high-performance liquid chromatography (DHPLC) has been used extensively to detect genetic variation. We used this method to detect and identify Yersinia pestis KIM5 ciprofloxacin-resistant...Full Text Available

2003-07-01

426

Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation  

Science.gov (United States)

This investigation describes the technique for the detection of the X-ray fluorescent radiation

1972-01-01

427

Integration of Microdialysis Sampling and Microchip Electrophoresis with Electrochemical Detection  

UK PubMed Central (United Kingdom)

Here we describe the fabrication, optimization, and application of a microfluidic device that integrates microdialysis (MD) sampling, microchip electrophoresis (ME), and electrochemical detection...Full Text Available

2008-12-01

428

Direct Detection Optical Intersatelllte Link at 220 Mbps Using ...  

Science.gov (United States)

on this technology has beenproposedas a payload on SpaceStation Freedom to be launched in the near future [1]. Direct detection 4-ary pulse position modula- ...

429

Development of a universal plate-agglutination test for detecting Haemophilus parasuis  

UK PubMed Central (United Kingdom)

Due to the serovar diversity in Haemophilus (H.) parasuis, it is difficult to develop a universal serological method for detection of this pathogen....Full Text Available

2010-12-01

430

Detecting Airborne Mercury by Use of Palladium Chloride Detecting ...  

Science.gov (United States)

Palladium chloride films have been found to be useful as ... when suitably prepared palladium chlo- ride films are exposed ... Like the palladium chloride ( PdCl2) ...

431

Trans-generational radiation-induced chromosomal instability in the female enhances the action of chemical mutagens  

Energy Technology Data Exchange (ETDEWEB)

Genomic instability can be produced by ionising radiation, so-called radiation-induced genomic instability, and chemical mutagens. Radiation-induced genomic instability occurs in both germinal and somatic cells and also in the offspring of irradiated individuals, and it is characterised by genetic changes including chromosomal rearrangements. The majority of studies of trans-generational, radiation-induced genomic instability have been described in the male germ line, whereas the authors who have chosen the female as a model are scarce. The aim of this work is to find out the radiation-induced effects in the foetal offspring of X-ray-treated female rats and, at the same time, the possible impact of this radiation-induced genomic instability on the action of a chemical mutagen. In order to achieve both goals, the quantity and quality of chromosomal damage were analysed. In order to detect trans-generational genomic instability, a total of 4806 ...

2008-04-02

432

Three-dimensional rotational angiography of the carotid arteries with high-flow injection from the aortic arch. Preliminary experience  

International Nuclear Information System (INIS)

Purpose: Three-dimensional rotational angiography (3DRA) is a new technique based on a rotational angiographic acquisition able to display arterial vessels in a 3D rendering mode. The system was mainly developed for neuroradiological evaluations but preliminary extracranial experiences have also been reported. The aim of our work was to compare the results of three-dimensional angiography of the carotid arteries done with high-flow injection of contrast medium from the aortic arch with the results of selective angiography. Materials and methods: Twenty patients underwent digital angiography of the supra-aortic vessels in order to quantify a stenosis of the carotid bifurcations previously detected at Doppler Ultrasound. Examinations were performed with the Philips Integris Allura system provided with the rotational angiography (RA) tool connected to a workstation for three-dimensional reconstruction able to display vessels in a 3D fashion (Volume Rendering, Shaded ...

433

Screening for congenital hypothyroidism in Lebanon - An example of newborn screening in absence of mandatory law  

International Nuclear Information System (INIS)

This paper presents a group's efforts to introduce national newborn screening in Lebanon. Tandem mass spectrometry (MS) technology offers the prospect of utilizing filter paper blood specimens to screen newborns for several metabolic disorders. In order to be cost-effective, it is necessary to have a mandatory newborn screening policy. At present such a policy is not available in Lebanon. A national screening survey for congenital hypothyroidism (CH) was carried out to assess the incidence of this anomaly in the Lebanese population. Such an initiative is essential as a first step for assessing the feasibility and cost of a national screening programme. Coated beads, blood spot standards for quality control and buffer solutions used for assays were prepared in-house to minimize costs. At first, samples of umbilical cord blood spots were assayed for TSH using IRMA technique. Those samples showing borderline or high values of TSH were then assayed for total T4 (TT4) ...

2004-10-01

434

SIMS analysis of silicon on insulator structures formed by high-dose O/sup +/ implantation into silicon  

Energy Technology Data Exchange (ETDEWEB)

Silicon on insulator (SOI) structures are promising candidates for the fabrication of VLSI circuits with very high packing densities. The preparation of such structures can now be achieved by high dose implantation of reactive ion species such as oxygen to produce buried layers of SiO/sub 2/ in silicon. In this paper we report experiments to depth profile these layered structures by SIMS. SOI samples have been prepared by implanting (100) silicon wafers with 400 keV molecular oxygen ions at a dose of 1.8x10/sup 18/ O/sup +/ cm/sup -2/. During the implantation the wafers were maintained at temperatures between 325 and 600/sup 0/C, using beam heating, which achieved in situ-annealing and ensured that the top silicon layer remained single crystal. Analysis was carried out on an Atomika DIDA-II spectrometer using 10 keV Ar/sup +/ ions with a low current density of less than 1 mA cm/sup -2/. During analysis negative secondary ions were monitored which provided a high ...

1983-12-15

435

Relative correlation of Jet-REMPI monitoring with adsorption tube sampling followed by TDS-CIS-GC/MS  

Energy Technology Data Exchange (ETDEWEB)

During earlier work rapid and highly sensitive Jet-REMPI (resonance-enhanced multiphoton ionization) mass spectrometry was applied for monitoring the effluent from thermal treatment of a filter dust during a de novo test under laboratory conditions. The sample, from ESP-Field 2 of an iron ore sintering plant, was already loaded with dioxins ({sigma}PCDD/F = 132 ng/g), their precursors (PCBz, PCPh) and other products of incomplete combustion. Heating filter dust in a temperature window 200-350 C under a flow of air results in further formation of these pollutants. As described elsewhere, on-line detection was mostly carried out using a non-selective ionization mode, to measure a wide range of compounds simultaneously. The changes of output suggest that the reaction products increase in chlorination level with time. Another explanation is that higherchlorinated compounds appear later as a consequence of lower volatility and stronger adsorption. However, due to mass ...

2004-09-15

436

Performance objectives for the Hanford immobilized low-activity waste (ILAW) performance assessment  

Energy Technology Data Exchange (ETDEWEB)

Before low-level waste may be disposed of, a performance assessment must be written and then approved by the DOE (DOE 1988a DOE 1999a). The performance assessment is to determine whether ''reasonable assurance'' exists that the performance objectives of the disposal facility will be met. The DOE requirements for waste disposal (DOE 1988a DOE 1999a) require the protection of public health and safety; and the protection of the environment. Although quantitative limits are sometimes stated (for example, the all-pathways exposure limit is 25 mrem/year), usually the requirements are stated in a general nature. Quantitative limits were established by: investigating all potentially applicable regulations as well as interpretations of the review panels which DOE has established to review performance assessments, interacting with program management to establish the additional requirements of the program, and interacting with the public (i.e., the Hanford ...

1999-09-09

437

Optically stimulated luminescence and thermoluminescence in CVD diamond and dosimetric evaluation in fields of ionizing radiation; Luminiscencia opticamente estimulada y termoluminiscencia en diamante DQV y evaluacion dosimetrica en campos de radiacion ionizante  

Energy Technology Data Exchange (ETDEWEB)

The optically stimulated luminescence (OSL) results a highly appropriate dosimetric technique for readings of absorbed radiation 'in alive' and 'in situ', as well as in real time. The CVD diamond on the other hand presents excellent qualities like radiation reader thanks to its reproducibility, radiation resistance, biocompatibility and non toxicity. The present work studies the answer of two diamond films pure and polluted with nitrogen (750 ppm) grown by the Chemical Vapor Deposition method (CVD) on silicon substrate (001) irradiated with beta (Sr-90) in the 0.833-100 Gy interval. The optical stimulation was carried out by 40 seconds with infrared laser (830 nm, 0.36 W/cm{sup 2}) and the filter BG-39 (300-600 nm) coupled the PM. The intensity and the decay of the hyperbolic type of the LOE curves were similar in both samples, for the non doped diamond were observed trapping states in 200-380 C being compared with those that it ...

2006-07-01

438

Nitrite in dew, fog, cloud and rain water: An indicator for heterogeneous processes on surfaces  

International Nuclear Information System (INIS)

Nitrite was measured in atmospheric liquid phase samples between 1998 and 2005 to investigate the heterogeneous formation of nitrous acid in the lower atmosphere, as well as to assess the quality of water recovered from dew. The samples were collected during ground-based cloud field experiments at different German mountain sites (Brocken, Schmucke, and Hohenpeissenberg) and at a site south of the Bordeaux urban area (France). Concentrations found in Bordeaux dew samples (up to 2800 ?gl-1) are comparable to those found elsewhere in urban fog and dew water and considerably higher than those detected in cloud water or rain. Particulate nitrite (and nitrate) as well as HNO2 (HNO3) data in air masses from a foothill site of Mt. Schmucke, before involved in cloud processing, are also presented. In clouds at Mt. Brocken, both the interstitial HNO2 gas and the aqueous phase nitrite concentration have been measured simultaneous. Significant deviations ...

439

Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden  

Energy Technology Data Exchange (ETDEWEB)

The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. The good agreement ...

2007-11-15

440

Characterizing explosives and blasting emissions  

Energy Technology Data Exchange (ETDEWEB)

With the advance of science, rise of public interest in environmental matters, and continuing erosion of air quality, Federal and state regulators are demanding an increasing complex array of data concerning emissions produced by burning and detonating energetic materials. The US Department of Defense, one of the world`s largest consumers of energetic materials, now must characterize combustion products resulting from open burning/open detonation disposal operations. The catch-all phrase ``below detection limits`` no longer satisfies the regulators who now want testing to delve into the ppt level for volatile organic compounds and ppt level for semivolatile organic compounds. Regulators are also expanding their scope of interest and may soon be asking for emissions data on training operations such as artillery firing. Providing this type of information is no longer an impossibility. The Army, as the single manager of conventional munitions for ...

1995-12-31

441

CT colonography: optimisation, diagnostic performance and patient acceptability of reduced-laxative regimens using barium-based faecal tagging  

Energy Technology Data Exchange (ETDEWEB)

To establish the optimum barium-based reduced-laxative tagging regimen prior to CT colonography (CTC). Ninety-five subjects underwent reduced-laxative (13 g senna/18 g magnesium citrate) CTC prior to same-day colonoscopy and were randomised to one of four tagging regimens using 20 ml 40%w/v barium sulphate: regimen A: four doses, B: three doses, C: three doses plus 220 ml 2.1% barium sulphate, or D: three doses plus 15 ml diatriazoate megluamine. Patient experience was assessed immediately after CTC and 1 week later. Two radiologists graded residual stool (1: none/scattered to 4: >50% circumference) and tagging efficacy for stool (1: untagged to 5: 100% tagged) and fluid (1: untagged, 2: layered, 3: tagged), noting the HU of tagged fluid. Preparation was good (76-94% segments graded 1), although best for regimen D (P = 0.02). Across all regimens, stool tagging quality was high (mean 3.7-4.5) and not significantly different among regimens. The HU of layered ...

2008-01-15

442

Application of continuous casting steel 100Cr6 (SAE 52100) for bearing balls  

Energy Technology Data Exchange (ETDEWEB)

The objective of the investigation was to study the feasibility of applying continuous casting steel 100Cr6 (SAE 52100) for bearing balls. It was found that two of three continuous casted steel batches have longer or at least similar rolling contact fatigue lifetimes compared to one ingot casted batch. For one of the continuous casted batches, the rolling contact fatigue lifetime was 30% less. The micro- and macrostructure and the residual stresses below the surface of the balls were comparable. There is also no obvious difference between the four batches in the metallurgical parameters like contents of oxygen, titanium and sulfur as well as in the distribution of carbides and their network. The reason for the shorter lifetime of one batch finally was found to be due not to the continuous casting process itself. There was a difference in the cross section of the different casting moulds, and by this in the speed of solidification. As a consequence an increased segregation of alloying ...

1998-12-31

443

Antisense-mediated suppression of C-hordein biosynthesis in the barley grain results in correlated changes in the transcriptome, protein profile, and amino acid composition  

DEFF Research Database (Denmark)

Antisense- or RNAi-mediated suppression of the biosynthesis of nutritionally inferior storage proteins is a promising strategy for improving the amino acid profile of seeds. However, the potential pleiotropic effects of this on interconnected pathways and the agronomic quality traits need to be addressed. In the current study, a transcriptomic analysis of an antisense C-hordein line of barley was performed, using a grain-specific cDNA array. The C-hordein antisense line is characterized by marked changes in storage protein and amino acid profiles, while the seed weight is within the normal range and no external morphological irregularities were observed. The results of the transcriptome analysis showed excellent correlation with data on changes in the relative proportions of storage proteins and amino acid composition. The antisense line had a lower C-hordein level and down-regulated transcript encoding C-hordein. The production of the S-rich B/gamma- and ...

2007-01-01

444

Antisense-mediated suppression of C-hordein biosynthesis in the barley grain results in correlated changes in the transcriptome, protein profile and amino acid composition  

DEFF Research Database (Denmark)

Antisense- or RNAi-mediated suppression of the biosynthesis of nutritionally inferior storage proteins is a promising strategy for improving the amino acid profile of seeds. However, the potential pleiotropic effects of this on interconnected pathways and the agronomic quality traits need to be addressed. In the current study, a transcriptomic analysis of an antisense C-hordein line of barley was performed, using a grain-specific cDNA array. The C-hordein antisense line is characterized by marked changes in storage protein and amino acid profiles, while the seed weight is within the normal range and no external morphological irregularities were observed. The results of the transcriptome analysis showed excellent correlation with data on changes in the relative proportions of storage proteins and amino acid composition. The antisense line had a lower C-hordein level and down-regulated transcript encoding C-hordein. The production of the S-rich B/ - and D-hordeins ...

2007-01-01

445

A designed screening study with prespecified combinations of factor settings  

Energy Technology Data Exchange (ETDEWEB)

In many applications, the experimenter has limited options about what factor combinations can be chosen for a designed study. Consider a screening study for a production process involving five input factors whose levels have been previously established. The goal of the study is to understand the effect of each factor on the response, a variable that is expensive to measure and results in destruction of the part. From an inventory of available parts with known factor values, we wish to identify a best collection of factor combinations with which to estimate the factor effects. Though the observational nature of the study cannot establish a causal relationship involving the response and the factors, the study can increase understanding of the underlying process. The study can also help determine where investment should be made to control input factors during production that will maximally influence the response. Because the factor combinations are observational, the chosen model matrix ...

2009-01-01

446

Scintigraphic demonstration of amebic liver abscesses with "1"3"1iodine labeled bromometronidazole  

International Nuclear Information System (INIS)

This case report demonstrates an hepatic amebic abscess by scintigrapy, utilizing a new radiopharmaceutical designed specifically for that purpose. The abscess is delineated as a positive lesion after twenty four hours. The agent, "1"3"1I-labeled bromometronidazole, may prove to be specific for the diagnosis of these abscesses. (orig.).

447

Relationship between O6-alkylguanine-DNA alkyltransferase activity and N-methyl-N'-nitro-N-nitrosoguanidine-induced mutation, transformation, and cytotoxicity in C3H/10T1/2 cells expressing exogenous alkyltransferase genes.  

UK PubMed Central (United Kingdom)

While a great deal of evidence has directly implicated the importance of O6-alkylation of guanine in the mutagenicity of alkylating agents, evidence demonstrating the oncogenic potential of this lesion...Full Text Available

1992-12-01

448

Radiologic findings of extraosseous Ewing's sarcoma  

International Nuclear Information System (INIS)

The purpose of this study is to evaluate the radiologic findings of the extraosseous Ewing's sarcoma. Six patients with pathologically confirmed extraosseous Ewing's sarcoma were retrospectively reviewed. Patients included two men and four women with an average age of 21.5 years (age range 9-48 years). Plain radiographs (six patients), magnetic resonance (MR) images (five patients), computed tomographic (CT) scans (three patients) and whole body scintigraphy (two patients) were reviewed and analyzed. Images were evaluated with regard to lesion location, size, margin, muscle or bone involvement and intrinsic imaging characteristics on CT and MRI. The tumors were located in the thigh (three patients), back (two patients) and upper arm (one patient). The tumors ranged in size from 2.3 cm to 7.5 cm (mean, 5.2 cm), were mainly well circumscribed and showed no evidence of calcification prior to treatment. Margins were well defined in four out of the six patients. Four ...

2005-09-01

449

Pre-therapy 18F-FDG PET quantitative parameters help in predicting the response to radioimmunotherapy in non-Hodgkin lymphoma  

International Nuclear Information System (INIS)

Radioimmunotherapy (RIT) is a new treatment option for patients with non-Hodgkin lymphoma (NHL). Response to RIT currently remains difficult to predict using conventional prognostic factors and could be refined using functional imaging. The goal of this work is to evaluate the value of 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in predicting response to Yttrium 90-labeled monoclonal antibodies for patients with NHL. Thirty-five patients with NHL who had undergone 18F-FDG PET prior to RIT with either 90Y-ibritumomab tiuxetan (group A; n=17) or 90Y-epratuzumab tetraxetan (group B; n=18) were included in this retrospective study. Four functional criteria were determined for each tumour lesion in a given patient: maximum and mean standard uptake values (SUVmax and SUVmean), functional lesion volume (LVol) and total lesion glycolysis (TLG, product of the volume and the SUVmean). For each patient, we ...

2010-03-01

450

Practical approach to the loss of smell  

Energy Technology Data Exchange (ETDEWEB)

Loss of the sense of smell can be easily confirmed in any physician's office by having the patient try to identify various odors. The etiology of anosmia can be extremely varied, including nasopharyngeal disorders such as rhinitis and tumors; neurologic conditions such as head trauma, neoplasms, vascular lesions and infections of the central nervous system; viral infections; familial and congenital disorders; drugs; industrial exposure; endocrine diseases, and several other disorders. The prognosis of anosmia is guarded, and its treatment depends on the etiology.

1982-09-01

451

Pericardio-diaphragmatic avulsion and concomitant rupture of the central tendon of the diaphragm.  

Science.gov (United States)

Two patients, treated for blunt thoracoabdominal trauma with ruptured diaphragm and concomitant avulsion of the pericardial sac in its entirety from the central tendon of the diaphragm, are presented. We do not think this entity has been reported before. We explain this type of lesion on the basis of embryological development of the pericardium at the level of the central tendon of the diaphragm. PMID:15302069

2004-09-01

452

Paraquat-induced pulmonary lesions : HRCT findings in long-term follow-up : a case report  

International Nuclear Information System (INIS)

We illustrate serial HRCT findings over a 16-month period in a 35-year-old woman who had ingested paraquat. Initial areas of ground-glass opacity changed into areas of multiple air cysts on follow up scan obtained five months after ingestion. A further follow-up scan obtained 16 months after ingestion showed improvement, with increased lung volume and normalized lung architecture.

1997-03-01

453

Morphological, Histochemical, Immunohistochemical, and Ultrastructural Characterization of Tumors and Dysplastic and Non-Neoplastic Lesions Arising in BK Virus/tat Transgenic Mice  

UK PubMed Central (United Kingdom)

To study the role in AIDS pathogenesis of the human immunodeficiency virus type 1 (HIV-1) Tat protein, a transactivator of viral and cellular genes, we generated transgenic mice with a recombinant DNA...Full Text Available

1999-04-01

454

Lesions that functionally disconnect the anterior and posterodorsal sub-regions of the medial amygdala eliminate opposite-sex odor preference in male Syrian hamsters (Mesocricetus auratus)  

UK PubMed Central (United Kingdom)

In many rodent species, such as Syrian hamsters, reproductive behavior requires neural integration of chemosensory information and steroid hormone cues. The medial amygdala processes both of...Full Text Available

2010-02-17

455

Interventional procedures in superficial lesions: the value of 2D with additional coronal reformatted 4D ultrasonography guidance  

International Nuclear Information System (INIS)

We wanted to assess the usefulness of four-dimensional (4D) ultrasonography (US), i.e., real-time three-dimensional US, as an adjunct for performing various US-guided interventional procedures in superficial lesion. Thirty-three patients were referred for US-guided interventional procedures for superficial lesions, including core biopsy in 19, fine- needle aspriation in eight, therapeutic drug injection in four and needle puncture in two. The procedures were performed under 4D US guidance. We reviewed the pathologic/cytologic results of the core biopsies or needle aspirations, and also the outcomes of drug injection or needle puncture. For all the patients who underwent 4D US-guided core biopsy, the specimens were adequate for making the pathological diagnosis, and specimens were successfully obtained for those patients who underwent 4D US-guided aspiration. The patients treated with 4D US-guided therapeutic drug injection or needle puncture ...

2006-03-01

456

Interventional Procedures in Superficial Lesions: The Value of 2D with Additional Coronal Reformatted 4D Ultrasonography Guidance  

UK PubMed Central (United Kingdom)

ObjectiveWe wanted to assess the usefulness of four-dimensional (4D) ultrasonography (US), i.e., real-time three-dimensional US, as an adjunct for performing various US-guided interventional...Full Text Available

2006-01-01

457

Glossitis of military workingn> dogs in south Vietnam; histopathologic observations.  

Science.gov (United States)

Glossitis, known clinically as "redtongue," was studied in tissues from 34 military working dogs (MWD) in the Republic of Vietnam. This condition was manifested grossly by loss of lingual papillae on the dorsal margins of the rostral third of the tongue. Microscopically, the principal lesions consisted of loss of filiform papillae, hemorrhage and edema in the lamina propria, acanthosis, and cellular infiltration. The cause of glossitis remains unknown at this time. PMID:1137213

1975-05-01

458

Endoscopic Ultrasound Guided Fine Needle Aspiration Biopsy in Diagnosis of Pancreatic and Peripancreatic Lesions: A Single Center Experience in Korea  

UK PubMed Central (United Kingdom)

Background/AimsAlthough endoscopic ultrasound guided fine needle aspiration (EUS-FNA) has been introduced and its use has been increasing in Korea, there have not been many reports...Full Text Available

2009-06-01

459

Cytology of a giant adult-type rhabdomyoma of the tongue  

British Library Electronic Table of Contents (United Kingdom)

Abstract Adult rhabdomyoma is a rare primary benign tumour of striated muscle origin that almost exclusively presents in the head and neck region with predilection for male. We herein report a case of an adult rhabdomyoma in a 67-year-old male with cytologic features. The lesions was located in the tongue extended to the left parapharyngeal region. We discuss the cytological findings with a brief review of the literature on this entity. Diagn. Cytopathol. 2010. 2010 Wiley-Liss, Inc.

2011-01-01

460

Computed Tomography in the study of pulmonary tuberculosis  

International Nuclear Information System (INIS)

The authors carried out a retrospective study on 4 years' work on a series of patients with proved active tuberculosis examined in the Departments of Bronchopneumology and Infectious Disease of the Arezzo Civil Hospital. The population was heterogenerous from the immunologic viewpoint. This paper compared the effectiveness of Computed Tomography (CT) with that of conventional chest radiography (CR) in the diagnosis and prognosis of tuberculosis. All patients underwent chest CR in double projection and conventional CT studies of the chest; 16 patients were also submitted to high resolution CT (HRCT). Consolidation was the most frequent parenchymal lesion in immunocompetent patients; it was often associated with cavitation, with no clear topographic prevalence in the upper lobes. Pleural effusion, as the only sign of disease and with empyema features, was found in 10 immunocompetent patients. No predominant pattern was found in the other two groups, even though ...

1997-01-01

461

Chorea-ballism associated with nonketotic hyperglycaemia or diabetic ketoacidosis: Characteristics of 25 patients in Korea  

British Library Electronic Table of Contents (United Kingdom)

Chorea-ballism is a rare form of movement disorder complicated by severe hyperglycaemia and in association with a contralateral basal ganglia lesion. We analysed the clinical characteristics of 25 Korean patients with chorea-ballism associated with nonketotic hyperglycaemia or diabetic ketoacidosis. Possible mechanisms of disease are also discussed.

2011-01-01

462

Characteristics of CDC group 1 and group 1-like coryneform bacteria isolated from clinical specimens.  

UK PubMed Central (United Kingdom)

Fifteen strains of CDC group 1 coryneform and biochemically similar bacteria were isolated from clinical specimens. Of the 15 strains isolated, 11 were derived from abscesses and purulent lesions, mostly...Full Text Available

1993-11-01

463

Bullous pemphigoid after radiation therapy  

Energy Technology Data Exchange (ETDEWEB)

Electron beam therapy applied to a lymph node metastasis from a squamous cell carcinoma was followed by the development of histologically and immunologically typical bullous pemphigoid, the lesions being initially strictly confined to the irradiation area. This observation suggests that the bullous pemphigoid antigen may be altered or unmasked by electron beam radiotherapy, leading subsequently to the production of autoantibodies. The disease in this case effectively responded to the administration of tetracycline and niacinamide, a therapeutic regimen described recently.

1988-02-01

464

Bilateral enlargement of the orbital muscles: first manifestation of renal adenocarcinoma; Espessamento da musculatura extrinseca orbitaria bilateralmente: manifestacao primaria de adenocarcinoma renal  

Energy Technology Data Exchange (ETDEWEB)

The authors present an unusual case of a patient with orbital metastases from renal carcinoma involving the extra ocular muscles bilaterally. The importance of computed tomography for the differential diagnosis with other orbital lesions is emphasized. (author)

2000-06-01

465

Adherence of Enterohemorrhagic Escherichia coli O157, O26, and O111 Strains to Bovine Intestinal Explants Ex Vivo?  

UK PubMed Central (United Kingdom)

We used bovine intestinal organ culture to study infection by enterohemorrhagic Escherichia coli serogroups O157, O26, and O111. We show colonization and attaching and effacing lesion...Full Text Available

2007-05-01

466

Abdominal masses in the pediatric age. Characterization by CT guided fine needle aspiration biopsy  

International Nuclear Information System (INIS)

CT-guided fine needle aspiration biopsy (FNAB) is known to improve diagnosis of expansive abdominal lesions, especially relative to more invasive procedure like explorative laparotomy. FNAB in not commonly use in pediatric patients because of their poor collaboration and of associated risks. The authors investigated the feasibility of FNAB in the pediatric age.

1999-04-01

467

A prospective evaluation of the safety and efficacy of the TAXUS Element paclitaxel-eluting coronary stent system for the treatment of de novo coronary artery lesions: Design and statistical methods of the PERSEUS clinical program  

UK PubMed Central (United Kingdom)

BackgroundPaclitaxel-eluting stents decrease angiographic and clinical restenosis following percutaneous coronary intervention compared to bare metal stents. TAXUS Element is a third-generation...Full Text Available

468

A DNA methyltransferase inhibitor and all-trans retinoic acid reduce oral cavity carcinogenesis induced by the carcinogen 4-nitroquinoline 1-oxide.  

Science.gov (United States)

The transcriptional silencing of some cell cycle inhibitors and tumor suppressors, such as p16 and retinoic acid receptor beta(2), by DNA hypermethylation at CpG islands is commonly found in human oral squamous carcinoma cells. We examined the effects of the DNA methyltransferase inhibitor 5-Aza-2'-deoxycytidine (5-Aza; 0.25 mg/kg body weight), all-trans retinoic acid (RA; given at 100 microg/kg body weight and 1 mg/kg body weight), and the combination of 5-Aza and the low-dose RA on murine oral cavity carcinogenesis induced by the carcinogen 4-nitroquinoline 1-oxide (4-NQO) in a mouse model. All the drug treatments were done for 15 weeks after a 10-week 4-NQO treatment. Mice in all drug treatment groups showed decreases in the average numbers of neoplastic tongue lesions. The combination of 5-Aza and RA effectively attenuated tongue lesion severity. Although all drug treatments limited the increase in the percentage of proliferating cell ...

2009-12-01

469

Quality assurance considerations in nuclear waste management  

International Nuclear Information System (INIS)

Proper use of quality assurance will provide the basis for an effective management control system for nuclear waste management programs. Control is essential for achieving successful programs free from costly losses and failures and for assuring the public and regulators that the environment and health and safety are being protected. The essence of quality assurance is the conscientious use of planned and systematic actions, based on selecting and applying appropriate requirements from an established quality assurance standard. Developing a quality assurance program consists of using knowledge of the technical and managerial aspects of a project to identify and evaluate risks of loss and failure and then to select appropriate quality assurance requirements that will minimize the risks. Those requirements are integrated into the project planning documents and are carried out as ...

470

Importance of health and environment as quality traits in the buying decision of organic products  

British Library Electronic Table of Contents (United Kingdom)

This paper aims to explore consumer preference for fresh vegetables labelled as organic in combination with health and environment related quality traits. The study decomposes organic farming into its main quality aspects and measures consumers' preference structure for organic, in general, and for specific organic quality traits in particular. By means of stated choice preference modelling, the following hypotheses are tested: consumers prefer health over environment related quality traits; the organic label plays a significant role in consumers' choice for organic products; organic farming is perceived as healthier and more environmentally friendly than conventional farming; purchase intention is mainly driven by health related quality traits; both health and environmental concerns influ...

2009-01-01

471

Free Time Management Contributes to Better Quality of Life: A Study of Undergraduate Students in Taiwan  

British Library Electronic Table of Contents (United Kingdom)

This study was designed to identify the relationship between free time management and quality of life, exploring whether the amount of free time or the way people using their free time relates to their quality of life. Data were collected from National Pingtung University of Science and Technology in Taiwan. Of the 500 questionnaires distribute, 403 usable questionnaires were received with an 81% response rate. The result has found a positive relationship between free time management and quality of life. Contrary to this, there was no significant relationship between time allocation and quality of life. Results might indicate that people who manage their free time well lead to better quality of life. Suggestions based on the observed relationship and directions for future researches were d...

2011-01-01

472

Assuring both quality and creativity in basic research  

Energy Technology Data Exchange (ETDEWEB)

How does one assure that both quality and creativity are obtained in basic research environments QA theoreticians have attempted to develop workable definitions of quality, but in more reflective moments, these definitions often fail to capture the deeper essence of the idea of quality.'' This paper asserts that creativity (as a product of the human mind) is a concrete interface between perfunctory definitions of quality (conformance to specifications) and more philosophical speculations about the nature of quality- related ultimates'' like elegance or beauty. In addition, we describe the distinction between creative ideas and creative acts and highlight one of the major inhibitors of creativity, fear. Finally we show that highly creative people often have an irreverent attitude toward boundaries and established authority, and discuss how one can ...

1990-04-12

473

A hybrid approach based on SERVQUAL and fuzzy TOPSIS for evaluating transportation service quality  

British Library Electronic Table of Contents (United Kingdom)

Managing service quality is vital to retain customer satisfaction and augment revenues for any business organization. Often it is difficult to assess service quality due to lack of quantifiable measures and limited data. In this paper, we present a hybrid approach based on SERVQUAL and fuzzy TOPSIS for evaluating service quality of urban transportation systems. The proposed approach consists of three steps. The first step involves development of a SERVQUAL based questionnaire to collect data for measuring transportation service quality. The participants provide linguistic assessments to rate the service quality criteria and the alternatives. In step 2, the linguistic ratings are combined through fuzzy TOPSIS to generate an overall performance score for each alternative. The alternative wit...

2011-01-01

476

Theoretical review of techniques for the remote detection of methane in underground coal mines  

Energy Technology Data Exchange (ETDEWEB)

The nature and relationship of methane to coal mines is discussed and sources of information are outlined. Methods of gas analysis in general and methods for the detection of methane in use in coal mines are described. Methods of remote detection of gases and those that have application for use in underground coal mining operations are discussed. The report represents recommendations on remote methane detection systems that may find application in underground coal mines. (20 refs.)

1983-01-01

481

Isolation and Identification of Mycoplasmas  

International Science & Technology Center (ISTC)

Isolation and Identification of Mycoplasmas, Development of Reliable Antigen for Mycoplasmas Detection and Oil-Based Vaccines

482

How the Air Force Should Stay Engaged in Computer Vision ...  

Science.gov (United States)

... 14 Face Detection ..... 14 Automated Mapping ...

2007-04-01

489

Creation of the BioBank, Early Detection and Discovery Biomarkers  

Science.gov (United States)

Pancreatic Cancer; Head and Neck Cancer; Breast Cancer

2011-04-03

493

Infrared radiation features of coal and rocks under loading  

Energy Technology Data Exchange (ETDEWEB)

Samples of fat coal-E, its roof sandstone-A and blind coal-W from two coal mines in Hebei Province of China were brought to the laboratory to study the features of infrared thermal images and radiation temperature in the course of uni-axial load and uni-axial cycle load. To check the results of infrared remote sensing detection, two other methods, acoustic emission detection and electrical resistance detection were also used. The AGA-782 thermalvision detected change of the temperature field of the samples` surfaces. The study showed that: (1) coal rocks and sandstone in the course of loading have three types of infrared thermal image features and three types of infrared radiation temperature features; (2) infrared detection is comparable with acoustic emission detection and electrical resistance detection. Generally, the infrared ...

1998-10-01

494

Validation of the treatment identification strategy of the HEDIS addiction quality measures: concordance with medical record review  

UK PubMed Central (United Kingdom)

BackgroundStrategies to accurately identify the occurrence of specific health care events in administrative data is central to many quality improvement and research efforts. Many...Full Text Available

495

Quality of life in the Iranian Blind War Survivors in 2007: a cross-sectional study  

UK PubMed Central (United Kingdom)

BackgroundQuality of Life measurements are necessary tools for effectively evaluating health services. In the population of patients afflicted with war-related blindness in Iran,...Full Text Available

496

Quality assessment of reporting of randomization, allocation concealment, and blinding in traditional chinese medicine RCTs: A review of 3159 RCTs identified from 260 systematic reviews  

UK PubMed Central (United Kingdom)

BackgroundRandomized controlled trials (RCTs) which are of poor quality tend to exaggerate the effect estimate and lead to wrong or misleading conclusions. The aim of this study...Full Text Available

497

Measuring quality of care in psychiatric emergencies: construction and evaluation of a Bayesian index.  

UK PubMed Central (United Kingdom)

OBJECTIVE. This study was conducted to determine whether an index for measuring quality of care for psychiatric emergencies is reliable and valid. DATA SOURCES/STUDY SETTING. The study used primary...Full Text Available

1993-06-01

498

Impact of an Electronic Medical Record on Diabetes Quality of Care  

UK PubMed Central (United Kingdom)

PURPOSE This study was designed to evaluate the impact of electronic medical record (EMR) implementation on quality of diabetes care.METHODS We conducted a 5-year longitudinal...Full Text Available

2005-07-01

499

ESTIMATION OF WATER QUALITY CRITERIA VIOLATION FREQUENCIES USING PEARSON PERCENTILES  

Science.gov (United States)

A numerical technique is developed for estimating water quality violation frequencies due to pollutant discharges from urban areas during combined sewer overflow events. The first four moments of in-stream pollutant concentration are found by integrating a pollutant loading - wat...

500

An interdisciplinary intervention for older Taiwanese patients after surgery for hip fracture improves health-related quality of life  

UK PubMed Central (United Kingdom)

BackgroundThe effects of intervention programs on health-related quality of life (HRQOL) of patients with hip fracture have not been well studied. We hypothesized that older patients...Full Text Available