WorldWideScience
1

Quality assurance requirements for installation, inspection, and testing of mechanical equipment and systems  

International Nuclear Information System (INIS)

The guide describes a method acceptable to the NRC staff for complying with the Commission's regulations with regard to quality assurance requirements for installation, inspection, and testing of mechanical equipment and systems for water-cooled and high-temperature gas-cooled nuclear power plants.

2

Supplementary quality assurance requirements for installation, inspection, and testing of mechanical equipment and systems for the construction phase of nuclear power plants  

International Nuclear Information System (INIS)

Requirements for the installation, inspection, and testing that assure the quality of important components of a nuclear power plant during construction are presented.

3

An approach to software quality assurance for robotic inspection systems  

International Nuclear Information System (INIS)

Software quality assurance (SQA) for robotic systems used in nuclear waste applications is vital to ensure that the systems operate safely and reliably and pose a minimum risk to humans and the environment. This paper describes the SQA approach for the control and data acquisition system for a robotic system being developed for remote surveillance and inspection of underground storage tanks (UST) at the Hanford Site.

1993-11-14

5

Supplementary quality assurance requirements for installation, inspection and testing of mechanical equipment and systems for the construction phase of nuclear power plants - reaffirmed 1980  

International Nuclear Information System (INIS)

This standard provides requirements and guidelines for installation, inspection and testing activities that assure the quality of important mechanical parts of a nuclear power plant not covered by the ASME Boiler and Pressure Vessel Code, Section III, during construction. These parts include those mechanical systems and components whose satisfactory performance is required: for the plant to operate reliably; to prevent accidents that could cause undue risk to the health and safety of the public; or to mitigate the consequences of such accidents if they were to occur. The requirements of this standard deal with the protection and control necessary to assure that the requisite quality of those important parts of the plant are preserved from the time items are removed from storage or receiving until they are incorporated into the plant up to but not including fuel loading for PWR plants and the completion ...

6

Development of QA/QC technology in Korea  

International Nuclear Information System (INIS)

KAERI (Korea Advanced Energy Research Institute) has performed research to develop the fabrication technology of CANDU nuclear fuel since 1981. Based on the satisfactory results of in-pile and out-of-pile tests of prototype nuclear fuel and the outstanding performance of 48 KAERI-made nuclear fuels in Wolsung(CANDU) power reactor, Korean government decided KAERI to supply all the nuclear fuels for Wolsung from 1988. In order to guarantee the safety and performance of nuclear fuel manufactured in mass production scale, well-organized quality assurance system and appropriate quality control techniques should be established. To establish the QA system, KAERI reviewed various QA standards and decided to establish QA system based on the 10 CFR 50 Appendix B. Quality control techniques was also revised to fit the mass production even though ...

1986-10-06

7

Fuel assemblies inspection system - (SICOM)  

Energy Technology Data Exchange (ETDEWEB)

An inspection system was developed for spent fuel assemblies of PWR so that to check their general state, perform dimensional control and measure oxide layer thickness of peripheral rods. (orig./HP)

1995-12-31

8

A Computer Vision System for Inspection of Light Emitting ...  

Science.gov (United States)

... Accession Number : ADD801284. Title : A Computer Vision System for Inspection of Light Emitting Diodes. Descriptive Note : Conference paper,. ...

1986-06-01

9

Process-integrated online monitoring of safety-relevant aluminum airbag pressure vessel components for a combined defect detection and material property determination by using contactless NDT (EMUS and EC)  

Energy Technology Data Exchange (ETDEWEB)

Airbag pressure vessels for the north-American market mainly are made by forging and by the use of steel alloys. In Europe aluminum alloys are common and the manufacturing process is extrusion of circular blanks - made from cold rolled plates - in a form applying a 100 t press at room temperature. Then by heat treatment the strength/hardness of the material is properly adjusted and after that the pressure vessel parts have to be continuously inspected with an inspection and handling cycle time of 3 s. Inspection of the axis-symmetric parts is asked for surface breaking extrusion defects as well as for surface parallel delaminations in the bulk volume. Furthermore, the material strength is a quality characteristic that has to be nondestructively registered and documented. The inspection is performed by eddy current probes and an EMAT, of which the eddy current impedance measurements ...

1999-07-01

10

Quality assurance (QA) training at Westinghouse including innovative approaches for achieving an effective QA programme and establishing constructive interaction  

International Nuclear Information System (INIS)

Experience of the Westinghouse Water Reactors Division with indoctrination and training of quality engineers includes training of personnel from Westinghouse divisions in the USA and overseas as well as of customers' personnel. A written plan is prepared for each trainee in order to fit the training to the individual's needs, and to cover the full range of information and activities. The trainee is also given work assignments, working closely with experienced quality engineers. He may prepare inspection plans and audit check lists, assist in the preparation of QA training modules, write procedures, and perform supplier surveillance and data analyses, or make special studies of operating systems. The trainee attends seminars and special courses on work-related technical subjects. Throughout the training period, emphasis is placed on inculcating an attitude of team work in the trainee so that the result ...

11

Robust line width estimation  

Energy Technology Data Exchange (ETDEWEB)

Fabrication of diffused titanium optical guides on a LiNbO/sub 3/ crystal substrate requires precise quality assurance. Light couplers in particular must be positioned within micron specifications. This requirement is the reason that the width of lines detected during microscopic inspection of the crystal is such an important parameter for quality evaluation. To assist in the inspection of these optical guides, a line width estimation program has been developed for an IBM PC based microscope inspection system. A digital image processing approach is used to develop an algorithm which can be tailored by the user for specific signal and noise characteristics. Default filter parameters, which can be updated and saved interactively by the user, are stored in a file on disk. The final program can be executed stand-alone or through a commercially available, ...

1986-07-01

12

An advanced NDA workstation for integrated safeguards  

International Nuclear Information System (INIS)

In this paper the authors describe the design and development of an advanced NDA workstation, which fits into an integrated data evaluation scheme for safeguards. This kind of instrument must be sort of an intelligent assistant to the inspection procedure, be able to generate as correct as possible measurements, guide the inspector throughout the procedure, and report descriptive data to the data evaluation system. The problem of improving the quality of the measurement is tackled using a simple expert system, which should convey in the instrument some of the physicist knowledge. The authors describe the hardware and software resources which were included in their design to reach the intended goal. A prototype of the machine has been built, and a preliminary software for Plutonium Isotopic Composition is under development.

1986-06-22

13

Robotic drilling system for titanium structures  

British Library Electronic Table of Contents (United Kingdom)

Manual drilling in titanium structures is a tedious and labor-intensive work. To reduce man-hour requirements while concurrently improving hole quality, we developed a robotic drilling system for this application. The lean system contains the product holding fixture, the industrial robot, the end effector, the control and sensor system, and the offline programming. The system functions include locating workpiece with a calibration stick or the vision system, weld mark inspection, one-sided clamping, drilling and reaming hole in material stack combinations of titanium and aluminum, and real-time thrust force feedback. The positional accuracy and the repeatability of the system have successfully been placed within the specification?s 0.3?mm tolerance and 0.2?mm tolerance, respectively. The d...

2011-01-01

14

ch4  

Science.gov (United States)

Earlier studies had concluded that the preferred direction of the rocket nozzle should ..... Center had to redesign the sensor canisters, brackets and cable supports. ... depending on inspection of the quality of the incoming pictures in real-time. ...

17

Robotics and Automation Activities at the Savannah River Site: A Site Report for SUBWOG 39F  

Energy Technology Data Exchange (ETDEWEB)

The Savannah River Site has successfully used robots, teleoperators, and remote video to reduce exposure to ionizing radiation, improve worker safety, and improve the quality of operations. Previous reports have described the use of mobile teleoperators in coping with a high level liquid waste spill, the removal of highly contaminated equipment, and the inspection of nuclear reactor vessels. This report will cover recent applications at the Savannah River, as well as systems which SRS has delivered to other DOE site customers.

1995-09-28

18

Development of a combined ultrasonic and eddy current inspection system for examination of the internal surfaces of water-filled austenitic piping  

Energy Technology Data Exchange (ETDEWEB)

After October 1993, Swedish BWR power plant operators will be required to present an inspection concept which will facilitate the nondestructive examination of recirculation system piping. According to the pertinent Swedish codes and standards, such inspections will be required to focus on internal pipe surfaces. Since it is impossible for external inspections to cover all essential areas with the necessary degree of sensitivity (geometry, beam attenuation), Siemens-KWU was commissioned to develop an inspection system which combines ultrasonic search units and eddy current probes to produce the required degree of examination sensitivity. A pipe crawler was developed to transport the inspection unit. This device can be used for the inspection of circumferential and longitudinal pipe welds, nozzle-to-pipe welds and RPV ...

1994-12-31

19

Quality assurance requirements for nuclear power plants in Hungary  

International Nuclear Information System (INIS)

In Hungary, legislation for nuclear power plants was developed at the end of the 1970s, among which is the quality assurance code for nuclear power plants. Hungarian practice is presented, including discussion of the requirements for quality assurance, qualification of the suppliers and inspection practices. The general requirements of quality assurance in the course of construction of a nuclear power plant are presented: quality assurance of technological equipment, fuel, electrical equipment, automatic instrumentations, building structures and technology.

20

Quantitative and qualitative aspects of agricultural products  

International Nuclear Information System (INIS)

The following aspects will be discussed: The main function of the Division of Inspection Services and its role in the Marketing of agricultural products; the shelf life of agricultural products: short review of present methods with a practical example of losses incurred due to limited keeping quality; irradiation and heat treatment: advantages of inhibited microbiological activities and undesirable chemical changes from a quality control point of view; quality standards: the basic principles of quality control; consequences of effective post-harvest treatment: export of deciduous and citrus fruit; the magnitude of the problem of poor keeping quality and quality requirements; other fruit; quantities and export limitations and vegetables; quantity and quality requirements; local marketing: fruit and vegetables subjected to ...

21

Inspection procedure and essential parameters in NDT qualification; Tarkastusohje ja olennaiset muuttujat NDT-paetevoeinnissae  

Energy Technology Data Exchange (ETDEWEB)

The objective of the inspection qualification is to ensure that applied non-destructive methods (NDT) have the required performance. The approach of the qualification process is systematic and carefully documented and therefore some new requirements can be seen concerning the composition of the documentation. There are also new document types, that only application of the inspection qualification requires. The most important of these is the technical justification, that includes the documented evidences concerning the performance of the inspection system. This publication includes two reports: 'Compilation of the inspection procedure' and 'Essential/influential parameters in NDT qualification'. The former of these discusses the issues to be considered in an inspection procedure especially from the point of view of the ...

2000-06-01

22

Inspection pig for gas pipeline  

Energy Technology Data Exchange (ETDEWEB)

The ultrasonic inspection pig system was described as being under development. This system was said to adopt the unique wheel type ultrasonic sensor which does not need couplant. This pig was designed to detect external corrosion in long-distance pipelines without interruption of the gas service. The wall-thickness measurement performance test and the travel performance test of the inspection pig in the test line confirmed that these performances satisfied the development specifications. However, the effect induced by the inner surface properties of the pipe and the influence of the pipe`s performance over long distances and for a long period of time still needed to be verified in an actual gas pipeline, and while the pipeline was actually in service. Improvements to the prototype model of the inspection pig were expected to include combinations of inspection ...

1992-12-31

23

Demands on quality assurance in operation  

International Nuclear Information System (INIS)

The present code requirements on quality assurance as well as the present praxice of quality assurance procedures in the operation of nuclear power plants are presented. On the example of recurring inspections the organizational and technical complications are shown with respect to the code and licensing requirements. Taking the present experiences into account suggestions are given how to transform the general requirements of KTA 1401 to quality assurance requirements during plant operation. (orig.).

1981-03-01

24

Evaluation of performance and characteristics of neutron radiography and standardization  

Energy Technology Data Exchange (ETDEWEB)

Neutron radiography has been put to practical use in foreign countries as one of nondestructive inspection technologies, but in Japan, its application to other scientific fields is mainly researched. The reason is, the neutron radiography apparatuses installed in Japan are hard to be industrially utilized for a number of reasons, but also the characteristics of neutron radiography are not clearly established, and it is not standardized. The part from a collimator through an object to a detector is called ``upstream``, the part of an image detector is called ``midstream``, and the part of image processing is called ``downstream``. The nonparallel property of beam, image distortion and the lack of sharpness, beam quality and the interaction of neutron beam with an object are discussed about the upstream. The intensity of neutron beam, the energy spectra, the effective total macroscopic cross section, the effective energy, the evaluation of ...

1995-02-01

25

Annual report on heavy water reactor fuel fabrication  

Energy Technology Data Exchange (ETDEWEB)

The CANDU-type nuclear fuel localization project started in 1981, and mass-production system completed in 1987 through the pilot scale demonstration of fuel manufacturing. Since the completion of the mass-production system, about 24,000 fuel bundles (450 ton-U) had been delivered to Wolsung Nuclear Power Plant by the end of 1992, according to the fuel supply contracts with KEPCO. The superiority of KAERI-made nuclear fuel has been demonstrated by having achieved the highest utilization factor in the world in 1992. In 1993, as contracted, 4,824 fuel bundles well fabricated and delivered to Wolsung Nuclear Power Plant. The process improvement, quality control, safety management, safeguards of nuclear materials and various kinds of audits have also been performed in the course for fuel manufacturing. Especially in 1993, the difficulties of the reduction of participating work-force were overcome by improving the manufacturing ...

1994-03-01

26

Research and development for treatment and disposal technologies of TRU waste  

International Nuclear Information System (INIS)

After the publication of the 2nd progress report of geological disposal of TRU waste in Japan, policy and general scheme of future study for the waste disposal in Japan was published by ANRE and JAEA. This annual report summarized aim and progress of individual problem, which was assigned into JAEA in the published policy and general scheme. The problems are as follows; characteristics of TRU waste and its geologic disposal, treatment and waste production, quality control and inspection methodology for waste, mechanical analysis of near-field, data acquisition and preparation on radionuclides migration, cementitious material transition, bentonite and rock alteration in alkaline solution, nitrate effect, performance assessment of the disposal system and decomposition of nitrate as an alternative technology. (author)

2007-04-22

27

Development of New Ground Inspection Techniques for the ...  

Science.gov (United States)

Integration of Eddy Current probes with MAUS scanning system has been demonstrated to produce scan rates of 36 sqft/hour. System will be designed to ...

28

Increased capability of Strassy: the decision making aid for the inspection of nuclear materials; Prolongement des capacites de Strassy: systeme d`aide a la decision pour le controle des matieres nucleaires  

Energy Technology Data Exchange (ETDEWEB)

The paper describes the latest developments in STRASSY (Strategy Assistance System), the strategy assistance system for the inspection of nuclear materials. The user can now select the fuel cycle he wishes to investigate from an initial range of 19 facilities. An inspection interface has been developed to enable the details and dates of inspections to be modified. One of the special features of the application of STRASSY in international safeguards is the taking into account of timeliness of detection; certain aspects of the time manager algorithms are presented and analysed, including the guaranteed existence of a solution. The results of a study of diversion paths in a simplified cycle consisting of our facilities are presented. Finally, the modifications necessary to enable STRASSY to be used for a posterior analysis of inspection results are discussed. ...

1994-12-31

29

UNS YMSCP QA support task: Quarterly technical progress report, January 1, 1991--June 30, 1991  

Energy Technology Data Exchange (ETDEWEB)

This report describes a quality assurance program plan for the Yucca Mountain Project. Aspects of the plan include: document control, equipment maintenance and calibration, process control, audits, computer software, and inspections. (CBS)

1991-07-30

32

Results of third regular inspection of No. 2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co. , Inc  

Energy Technology Data Exchange (ETDEWEB)

The third regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from December 27, 1988 to May 25, 1989. The parallel operation was resumed on April 28, 1989, 123 days after the parallel off. The facilities which were the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation and emergency electric power generation system. On the facilities which were the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out. As the results, significant in indication was observed in 8 bolts for fixing the flow-changing vanes of primary coolant pumps, and broken valve spindles were found, but other abnormality was not found. ...

1990-03-01

33

Results of second regular inspection of No.2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc  

International Nuclear Information System (INIS)

The second regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from October 5, 1987 to January 8, 1988. the parallel operation was resumed on December 8, 1987, 65 days after the parallel off. The facilities as the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation, and emergency power generation system. On these facilities as the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out, and abnormality was not found at all. The works related to this regular inspection were accomplished within the range of allowable dose based on the relevant laws. The main reconstruction works carried ...

1988-01-01

34

Results of second regular inspection of No. 2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co. , Inc  

Energy Technology Data Exchange (ETDEWEB)

The second regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from October 5, 1987 to January 8, 1988. the parallel operation was resumed on December 8, 1987, 65 days after the parallel off. The facilities as the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation, and emergency power generation system. On these facilities as the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out, and abnormality was not found at all. The works related to this regular inspection were accomplished within the range of allowable dose based on the relevant laws. The main reconstruction works carried ...

1988-08-01

35

Identification and characterization of conservative organic tracers for use as hydrologic tracers for the Yucca Mountain Site Characterization Project: Quality Assurance Project Plan; Quarterly technical progress report, January 1, 1993--March 31, 1993  

Energy Technology Data Exchange (ETDEWEB)

Studies continued on organic tracers for use as hydrologic tracers as part of the Yucca Mountain Site Characterization project. This subject report for the quarter 01/01/93 through 03/31/93 discusses the following issues: project organization and responsibilities; quality assurance program; design control; procurement document control; instructions, procedures, and drawings; document control; control of purchased items and services; identification and control of items; control of processes; inspection; test control; control of measuring and test equipment; handling, storage, and shipping; inspection, test, and operating status; control of nonconforming items and conditions; corrective action; quality assurance records; audits; software quality assurance; and scientific investigation.

1993-02-25

36

Development of video probe system for inspection of feeder pipe support in calandria reactor  

Energy Technology Data Exchange (ETDEWEB)

There are 760 feederpipes, which they are connected to inlet/outlet of the 380 pressure tube channels on the front of the calandria, in CANDU-type Reactor of Wolsung Nuclear Power Plant. As an ISI(In-Service Inspection) and PSI (Post- Service Inspection) requirements, maintenance activities of measuring the thickness of curvilinear part of feederpipe and inspecting the feederpipe support area within calandria are needed to ensure continued reliable operation of nuclear power plant. And untrasonic probe is used to measure the thickness of curvilinear part of feederpipe, however workers are exposed to radioactivity irradiation during the measurement period. But, it is impossible to inspect feederpipe support area thoroughlv because of narrow and confined accessibility, that is, an inspection space between the pressure tube channels is less than 100mm and pipes in feederpipe support ...

2000-07-01

37

On-line measurement and inspection technologies of surface properties of steel sheets; Koban hyomen hinshitsu no onrain keisoku oyobi kensa gijutsu  

Energy Technology Data Exchange (ETDEWEB)

In steel production lines such as pickling lines, cold rolling mills and coil processing lines, the needs for on-line continuous measurement of surface quality and property of products and on-line inspection of surface defects have become strong. This is because user requirements for the surface quality of various products have become severer than before and besides, expectations are running high on the side of manufacturers for higher speeds of production lines and higher quality by the adoption of automatic inspection. As for the measurement of surface quality, continuous measurements along the full length of a steel strip are required in order to overcome problems derived from off-line, batch measurements that cannot satisfy user's demands for quality assurance. As for surface defects detection, various kinds of methods have been ...

1999-12-01

38

Visual inspection technology of the narrow and small confined area for monitoring feederpipe support of pressure tube in calandria reactor  

Energy Technology Data Exchange (ETDEWEB)

There are 760 feederpipes, which they are connected to inlet/outlet of the 380 pressure tube channels on the front of the calandria, in CANDU-type Reactor of Wolsung Nuclear Power Plant. As an ISI(In-Service Inspection) and PSI (Post-Service Inspection) requirements, maintenance activities of measuring the thickness of curvilinear part of feederpipe and inspecting the feederpipe support area within calandria are needed to ensure continued reliable operation of nuclear power plant. And ultrasonic probe is used to measure the thickness of curvilinear part of feederpipe, however workers are exposed to radioactivity irradiation during the measurement period. But, it is exposed to radioactivity irradiation during the measurement period. But, it is impossible to inspect feederpipe support area thoroughly because of narrow and confined accessibility, that is , an inspection space between ...

1999-12-01

39

Application of automatic inspection system to nondestructive test of heat transfer tubes of primary pressurized water cooler in the high temperature engineering test reactor. Joint research  

International Nuclear Information System (INIS)

Heat transfer tubes of a primary pressurized water cooled (PPWC) in the high temperature engineering test reactor (HTTR) form the reactor pressure boundary of the primary coolant, therefore are important from the viewpoint of safety. To establish inspection techniques for the heat transfer tubes of the PPWC, an automatic inspection system was developed. The system employs a bobbin coil probe, a rotating probe for eddy current testing (ECT) and a rotating probe for ultrasonic testing (UT). Nondestructive test of a half of the heat transfer tubes of the PPWC was carried out by the automatic inspection system during reactor shutdown period of the HTTR (about 55% in the maximum reactor power in this paper). The nondestructive test results showed that the maximum signal-to-noise ratio was 1.8 in ECT. Pattern and phase of Lissajous wave, which were obtained for the ...

40

A pilot application of risk-based methods to establish in-service inspection priorities for nuclear components at Surry Unit 1 Nuclear Power Station  

International Nuclear Information System (INIS)

As part of the Nondestructive Evaluation Reliability Program sponsored by the US Nuclear Regulatory Commission, the Pacific Northwest Laboratory is developing a method that uses risk-based approaches to establish in-service inspection plans for nuclear power plant components. This method uses probabilistic risk assessment (PRA) results and Failure Modes and Effects Analysis (FEMA) techniques to identify and prioritize the most risk-important systems and components for inspection. The Surry Nuclear Power Station Unit 1 was selected for pilot applications of this method. The specific systems addressed in this report are the reactor pressure vessel, the reactor coolant, the low-pressure injection, and the auxiliary feedwater. The results provide a risk-based ranking of components within these systems and relate the target risk to target failure probability values for individual ...

41

Flue-gas desulfurization inspection and performance evaluation. Manual  

Energy Technology Data Exchange (ETDEWEB)

The intent of this manual is to provide inspectors from Federal and state environmental agencies with information regarding the problems that plague lime/limestone slurry flue-gas desulfurization (FGD) systems that will aid them in their inspections and performance evaluations of these systems with respect to compliance with the emission standards that have evolved since the passage of the 1970 Clean Air Act. A unique feature of the manual is its structure as a tool, or working document, which will accompany the inspector on each plant inspection. Thus, the document is presented in user friendly fashion and tailored to provide practical information for its intended use--to assist in the systematic inspection of an FGD system to determine present and future compliance status. The approach entails the use of nomographs, checklists, matrices, simplified diagrams, ...

1985-10-01

42

Research and development quality assurance planning  

Energy Technology Data Exchange (ETDEWEB)

Planning for quality assurance (QA) in research and development (R D) is like stealing eggs without waking up the chickens. The QA program should be as unobtrusive as possible. Researchers require a QA program that affords them an environment capable of supporting repeatable experiments with accurate data without unduly stifling their creative abilities. Careful advance planning ensures that the intensity of control provided by quality-related systems is commensurate with the importance and scope of the activities being performed. Good scientific practices applied to small bench-scale projects may require minimal additional controls. As projects increase in size and complexity the controls imposed through planning must, by necessity, be increased. Research and development QA planning, just like any other planning, involves all affected individuals. The application of control systems is determined by ...

1990-05-14

43

Results of 1st regular inspection of No.2 unit in Sendai Nuclear Power Plant  

International Nuclear Information System (INIS)

This report presents results of the 1st regular inspection of the No.2 unit of the Sendai Nuclear Power Plant. It was carried out during the period from September 22, 1986, to December 24, 1986. The inspection covered the main unit of the nuclear reactor, facilities for the nuclear reactor cooling system, facilities for the instrumentation control system, fuel facilities, radiation control facilities, disposal facilities, nuclear reactor containment facilities, and emergency power generation system. Checking of appearance, disassemblage, leak and functions-performance of these facilities was conducted and no abnormalities were found. All operations involved in the inspection were performed under conditions within the permissible dose as specified in the applicable laws. No major modification work was carried out during the period of the regular ...

1987-01-01

44

Results of 1st regular inspection of No. 2 unit in Sendai Nuclear Power Plant  

Energy Technology Data Exchange (ETDEWEB)

This report presents results of the 1st regular inspection of the No. 2 unit of the Sendai Nuclear Power Plant. It was carried out during the period from September 22, 1986, to December 24, 1986. The inspection covered the main unit of the nuclear reactor, facilities for the nuclear reactor cooling system, facilities for the instrumentation control system, fuel facilities, radiation control facilities, disposal facilities, nuclear reactor containment facilities, and emergency power generation system. Checking of appearance, disassemblage, leak and functions-performance of these facilities was conducted and no abnormalities were found. All operations involved in the inspection were performed under conditions within the permissible dose as specified in the applicable laws. No major modification work was carried out during the period of the regular ...

1987-09-01

45

Quality assurance requirements for control of procurement of items and services for nuclear power plants - approved 1976  

International Nuclear Information System (INIS)

This standard describes requirements and provides guidelines for the control of activities to be exercised during procurement of items and services which affect the quality of nuclear power plants. These requirements and guidelines apply to procurement activities for items and services such as designing, purchasing, fabricating, handling, shipping, storage, cleaning, constructing, erecting, installing, inspecting, testing, maintaining, repairing, initial fueling, refueling, and modifying.

46

Quality assurance requirements for control of procurement items and services for nuclear fuel reprocessing facilities  

International Nuclear Information System (INIS)

Requirements and guidelines are provided for the control of activities to be exercised during procurement of items and services which affect the quality of nuclear facilities. These requirements and guidelines apply to procurement activities for items and services such as designing, purchasing, fabricating, handling, shipping, storing, cleaning, constructing, erecting, installing, inspecting, texting, maintaining and modifying.

47

PRA and Risk Informed Analysis  

Science.gov (United States)

The Boiler and Pressure Vessel Code (BPVC) of the American Society of Mechanical Engineers (ASME) has introduced a risk based approach into Section XI that covers Rules for Inservice Inspection of Nuclear Power Plant Components. The risk based approach requires application of the probabilistic risk assessments (PRA). Because no industry consensus standard existed for PRAs, ASME has developed a standard to evaluate the quality level of an available PRA needed to support a given risk based application. The paper describes the PRA standard, Section XI application of PRAs, and plans for broader applications of PRAs to other ASME nuclear codes and standards. The paper addresses several specific topics of interest to Section XI. Important consideration are special methods (surrogate components) used to overcome the lack of PRA treatments of passive components in PRAs. The approach allows calculations of conditional core damage probabilities ...

2006-01-01

48

PRA and Risk Informed Analysis  

Energy Technology Data Exchange (ETDEWEB)

The Boiler and Pressure Vessel Code (BPVC) of the American Society of Mechanical Engineers (ASME) has introduced a risk based approach into Section XI that covers Rules for Inservice Inspection of Nuclear Power Plant Components. The risk based approach requires application of the probabilistic risk assessments (PRA). Because no industry consensus standard existed for PRAs, ASME has developed a standard to evaluate the quality level of an available PRA needed to support a given risk based application. The paper describes the PRA standard, Section XI application of PRAs, and plans for broader applications of PRAs to other ASME nuclear codes and standards. The paper addresses several specific topics of interest to Section XI. Important consideration are special methods (surrogate components) used to overcome the lack of PRA treatments of passive components in PRAs. The approach allows calculations of conditional core damage probabilities both for ...

2006-01-01

49

PRA and Risk Informed Analysis  

International Nuclear Information System (INIS)

The Boiler and Pressure Vessel Code (BPVC) of the American Society of Mechanical Engineers (ASME) has introduced a risk based approach into Section XI that covers Rules for Inservice Inspection of Nuclear Power Plant Components. The risk based approach requires application of the probabilistic risk assessments (PRA). Because no industry consensus standard existed for PRAs, ASME has developed a standard to evaluate the quality level of an available PRA needed to support a given risk based application. The paper describes the PRA standard, Section XI application of PRAs, and plans for broader applications of PRAs to other ASME nuclear codes and standards. The paper addresses several specific topics of interest to Section XI. Important consideration are special methods (surrogate components) used to overcome the lack of PRA treatments of passive components in PRAs. The approach allows calculations of conditional core damage probabilities both for ...

50

Ceramic inspection system  

Science.gov (United States)

A system for inspecting a ceramic component. The ceramic component is positioned on a first rotary table. The first rotary table rotates the ceramic component. Light is directed toward the first rotary table and the rotating ceramic component. A detector is located on a second rotary table. The second rotary table is operably connected to the first rotary table and the rotating ceramic component. The second rotary table is used to move the detector at an angle to the first rotary table and the rotating ceramic component.

2006-05-16

51

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

International Nuclear Information System (INIS)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-22

52

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

Energy Technology Data Exchange (ETDEWEB)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-01

53

B Plant treatment, storage, and disposal (TSD) units inspection plan  

Energy Technology Data Exchange (ETDEWEB)

This inspection plan is written to meet the requirements of WAC 173-303 for operations of a TSD facility. Owners/operators of TSD facilities are required to inspection their facility and active waste management units to prevent and/or detect malfunctions, discharges and other conditions potentially hazardous to human health and the environment. A written plan detailing these inspection efforts must be maintained at the facility in accordance with Washington Administrative Code (WAC), Chapter 173-303, ``Dangerous Waste Regulations`` (WAC 173-303), a written inspection plan is required for the operation of a treatment, storage and disposal (TSD) facility and individual TSD units. B Plant is a permitted TSD facility currently operating under interim status with an approved Part A Permit. Various operational systems and locations within or under the control of B Plant have been ...

1996-04-26

54

Multiple-element eddy current probes for enhanced inspection  

Energy Technology Data Exchange (ETDEWEB)

Eddy current inspection methods are widely used for the nondestructive evaluation (NDE) of tubular products. Specifically, the sensors and instrumentation are designed to detect and characterize changes in a material's electrical and magnetic properties produced by the presence of discontinuities. A recent major enhancement in eddy current inspection technology has been the development of computer interfacing for data collection, analysis, and display. This breakthrough has led to multiple-frequency testing, eddy current imaging, and automated data interpretation systems that significantly enhance both capabilities and reliability of the eddy current inspection. In addition to the clear advantages in data processing, computer interfacing also permits the design and creation of unique sensors that further enhance eddy current inspection capabilities. Perhaps the most ...

1993-07-01

55

Optimal inspection and replacement periods of the safety system in Wolsung Nuclear Power Plant Unit 1 with an optimized cost perspective  

Energy Technology Data Exchange (ETDEWEB)

In this work, a model for determining the optimal inspection and replacement periods of the safety system in Wolsung Nuclear Power Plant Unit 1 is developed, which is to minimize economic loss caused by inadvertent trip and the system failure. This model uses cost benefit analysis method and the part for optimal inspection period considers the human error. The model is based on three factors as follows: (i) The cumulative failure distribution function of the safety system, (ii) The probability that the safety system does not operate due to failure of the system or human error when the safety system is needed at an emergency condition and (iii) The average probability that the reactor is tripped due to the failure of system components or human error. The model then is applied to evaluate the safety ...

1996-01-01

56

Risk-based inspection in ASME Section XI  

International Nuclear Information System (INIS)

By 1970 the first edition of the ASME Code Section XI, Inservice Inspection of Nuclear Reactor Coolant Systems was published. From its inception, the Section XI inservice inspection scope was based on a fundamental risk-based selection process. In other words the inservice inspection scope included components where the consequences of a pressure boundary failure were high. Once the consequence significant system boundaries were established, inspections would then be performed at locations believed to be most susceptible service induced failure. Current Section XI requirements require that inspection locations be selected on the basis of peak stress and fatigue usage values contained in the Design Reports. These original stress calculations were designed to qualify a design and assure that the plant would provide reliable service throughout ...

1996-07-21

57

Topical Report ''Corrosion Evaluation of LLW2 Skid-B Weld Failure Mechanisms (44139-92)  

Energy Technology Data Exchange (ETDEWEB)

An independent investigation of pipe welding leaks from the Low-Level Waste 2 (LLW2) Skid-B System for the possibilities of improper welding (IW), microbiologically influenced corrosion (MIC), sensitization, chloride pitting corrosion (CPC), and intergranular stress corrosion cracking (IGSCC) was conducted. The results show the prevailing mechanisms that caused the leaks are identified as IW, CPC, and the improper selection of weld filler material for the base metals in an environment of the North Plateau underground water. These is no evidence of MIC, sensitization, or IGSCC. The chloride pitting corrosion mechanism that took place at all the welds are also described. All the pipelines were replaced with polyvinyl chloride (PVC) for cost saving and the LLW2 Skid B System has been successfully operating since 1999. This report summarizes the findings and recommendations associated with preventive measures for future operations. The LLW2 ...

2001-05-31

58

GASVOL 18'' gas pipeline - risk based inspection study  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a risk based approach and inspection planning as part of the Pipeline Integrity Management (PIM) system for the 95.5 km long 18'' GASVOL gas pipeline in the South eastern region of Brazil transporting circa 5 000 000 m3 dry gas per day. Pipeline systems can be subject to several degradation mechanisms and inspection and monitoring are used to ensure system integrity. Modern pipeline regulations and codes are normally based on a core safety or risk philosophy. The detailed design requirements presented in design codes are practical interpretations established so as to fulfill these core objectives. A given pipeline, designed, constructed and installed according to a pipeline code is therefore the realization of a structure, which, along its whole length, meets the applicable safety objectives of that code. The main objective of Pipeline ...

2003-07-01

59

Multichannel radiometric inspection systems with half-tone visualization of radiation shadow images. 1. Mathematical model  

International Nuclear Information System (INIS)

A mathematical model of multichannel radiometric inspection system was developed, in which the measurement results are reproduced in the form of a half-tone image equivalent to the radiation image of the irradiated object. The model makes the following assumptions: the beam of radiation is fan-shaped; the object of inspection is scanned discretely; the focal spot of the source is rectangular; the apertures of the detector are round, and the detectors themselves are equidistant from the sources, aimed at it, and form a close-packed array; the signals from the detectors are processed according to a time scheme; and the measurement results are corrected in a computer for normalizing the gains of the channels of the system. The mathematical model can serve as the basis for developing a method of calculating the optimal parameters of a multichannel radiometric system with visualization ...

60

Results of the remote sensing feasibility study for the uranium hexafluoride storage cylinder yard program  

Energy Technology Data Exchange (ETDEWEB)

The US DOE manages the safe storage of approximately 650,000 tons of depleted uranium hexafluoride remaining from the Cold War. This slightly radioactive, but chemically active, material is contained in more than 46,000 steel storage cylinders that are located at Oak Ridge, Tennessee; Paducah, Kentucky; and Portsmouth, Ohio. Some of the cylinders are more than 40 years old, and approximately 17,500 are considered problem cylinders because their physical integrity is questionable. These cylinders require an annual visual inspection. The remainder of the 46,000-plus cylinders must be visually inspected every four years. Currently, the cylinder inspection program is extremely labor intensive. Because these inspections are accomplished visually, they may not be effective in the early detection of leaking cylinders. The inspection program requires approximately 12--14 ...

1997-02-01

61

The development of PHWR fuel fabrication in Korea  

International Nuclear Information System (INIS)

Korea Advanced Energy Research Institute (KAERI) started a research project to develop the PHWR (CANDU) nuclear fuel fabrication technology in 1981. Based on the results of the intensive developmental work, several prototype fuel bundles were fabricated and tested in the Hot Test Loop at KAERI continuously in 1983 and 1984. After that, irradiation test and post-irrradiation examination were carried out for two KAERI-made fuel bundles at Chalk River Nuclear Laboratories in Canada in 1984. Since the results of in-pile and out-of-pile tests with prototype fuel bundles proved to be satisfactory, 48 additional fuel bundles were loaded in Wolsung reactor (CANDU) in 1984 and 1985, and all of them were discharged without a defect after excellent performance in the power reactor. In 1985, the Korean government decided that KAERI supplies all the fuel necessary for the Wolsung reactor. For the mass production of nuclear fuel bundle, several process equipment, facilities and automation methods ...

1987-09-07

62

Eddy current inspection of superconducting cable during manufacturing  

Energy Technology Data Exchange (ETDEWEB)

The downstream failure of cable during winding, insulating, coil winding, and coil assembly is a significant issue in magnet production. The impact of these failures are costly both financially, and from the time to recover from this downstream failure. The current approach to cabling has been to visually inspect the cable for any gross defects during cabling. To date this has been effective in finding small defects such as crossovers for example, which drastically reduce the mechanical integrity of the strand, and thus the cable itself. But because of the large volume of cable which will be manufactured an automated flaw detection system which can inspect the cable and detect these type of defects will be needed. We have recently done an on-line experiment using an Eddy current system, and specialized Eddy current probes to inspect cable during manufacturing. We will present the ...

1992-03-01

63

Eddy current inspection of superconducting cable during manufacturing  

International Nuclear Information System (INIS)

The downstream failure of cable during winding, insulating, coil winding, and coil assembly is a significant issue in magnet production. The impact of these failures is costly both financially and because of the time needed to recover from them. The current approach to cabling has been to visually inspect the cable for any gross defects during cabling. To date this has been effective in finding small defects such as crossovers, which drastically reduce the mechanical integrity of the strand and thus of the cable itself. But because of the large volume of cable that will be manufactured, an automated flaw detection system that can inspect the cable and detect these types of defects will be needed. We have recently done an on-line experiment using an Eddy current system and specialized Eddy current probes to inspect cable during manufacturing. We will present the results of our ...

1992-03-04

64

Use of the acoustic method for checking the quality of concrete of hydroelectric and pumped storage stations  

Energy Technology Data Exchange (ETDEWEB)

This article describes acoustic methods used in the in-service inspection of the dams and peripheral concrete structures of the Toktogul, Kurpsai, and Bratsk hydroelectric and pumped storage plants. The tests were conducted to assess the compression strength, elasticity, and tensile strength of the concretes. Comparative evaluations against drill core studies proved the acoustic methods to be sufficiently accurate in predicting aging behavior and loss of mechanical and physical integrity in the concretes.

1987-09-01

65

Study of fitness-for-purpose criteria shows promise for pipeline girth-weld quality  

Energy Technology Data Exchange (ETDEWEB)

This article illustrates what typical accept/reject curves might look like and discusses progress made in developing the required inspection techniques for flaw dimensioning. Consideration is given to the relative significance of blunt versus planar types of flaws, and of inherent limitations to the depths of certain types of flaws. Finally, consideration is given to the realities of implementing proposed procedures under field conditions. These are summarized in a series of technical options for implementation of program results.

1983-07-01

66

On the development of the METAR family of inspection tools  

Energy Technology Data Exchange (ETDEWEB)

Since 1998, Hydro Quebec Research Centre (IREQ), in collaboration with Gentilly-2, has been working on the development of inspection devices for the feeder tubes of CANDU power plants. The first tool to come out of this work was the Metar bracelet, now used throughout the CANDU utilities, consisting of 14 ultrasonic probes held in place in a rigid bracelet to measure the thickness of the pipes and moved around manually along the pipe. Following the success of the Metar, a motorized version, i.e. the Crawler, has been developed to inspect beyond the operator arm's reach to access hard to reach place or further down the pipes in the reactor. This new system has been tested at 3 different stations and will be commercially available soon. Finally, the same technology was used to develop a motorized 2-axis crack detection device to answer new concerns about the feeder. Other configurations, depending on the demands from ...

2003-07-01

67

Final report of the second dye-tracer test at the Chesnut Ridge Security Pits, Y-12 Plant, Oak Ridge, Tennessee  

Energy Technology Data Exchange (ETDEWEB)

Martin Marietta Energy Systems, Inc. (Energy Systems) manages a closed hazardous waste disposal unit, Chestnut Ridge Security Pits (CRSP), in the form of two trenches and several auger-holes, located on top of the eastern portion of Chestnut Ridge at the Department of Energy (DOE) Oak Ridge Y-12 Plant in Tennessee. The groundwater monitoring system for the unit presently consists of a network of upgradient and downgradient monitor wells. To investigate the discharge of groundwater to springs and streams, Energy Systems, through Geraghty and Miller, Inc., conducted an initial dye-tracer study during the driest part of 1990. The dye was detected at some of the monitoring sites, but verification was necessary due to the proximity of some sites to extraneous dye sources. Based on the results of the initial study, Energy Systems recommended to the Tennessee Department of Environment and ...

1992-11-01

68

PROBE FOR FLOW PASSAGE INSPECTION  

J-STORE (Japan)

Full Text Available

2007-05-11

69

Quality assurance requirements in nuclear systems  

International Nuclear Information System (INIS)

(1974). United States Lingafelter, JW Nuclear Services Corp., Campbell, CA

1974-09-23

72

Spent Fuel Transfer to Dry Storage Using Unattended Monitoring System  

Energy Technology Data Exchange (ETDEWEB)

There are 4 CANDU reactors at Wolsung site together with a spent fuel dry storage associated with unit 1. These CANDU reactors, classified as On-Load Reactor (OLR) for Safeguards application, change 16- 24 fuel bundles with fresh fuel in everyday. Especially, the spent fuel bundles are transferred from spent fuel bays to dry storage throughout a year because of the insufficient capacity of spent fuel pond. Safeguards inspectors verify the spent fuel transfer to meet safeguards purposes according to the safeguards criteria by means of inspector's presence during the transfer campaign. For the verification, 60-80 person-days of inspection (PDIs) are needed during approximately 3 months for each unit. In order to reduce the inspection effort and operators' burden, an Unattended Monitoring System (UMS) was designed and developed by the IAEA for the verification of spent fuel bundles transfers from wet storage ...

2009-05-15

73

Real-time neutron radiography; Radiografia com neutrons em tempo-real  

Energy Technology Data Exchange (ETDEWEB)

The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the {gamma}-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10{sup 6}n/cm{sup 2}s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/{gamma} ratio {approx} 10{sup 6}n/cm{sup 2}mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame ...

2000-07-01

74

Real-time neutron radiography  

International Nuclear Information System (INIS)

The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the #gamma#-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10"6n/cm"2s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/#gamma# ratio #approx# 10"6n/cm"2mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame grabber and a ...

2000-01-01

75

Eddy current probe development based on a magnetic sensor array; Developpement d'un imageur magnetique pour le controle non destructif par courants de Foucault  

Energy Technology Data Exchange (ETDEWEB)

This research deals with in the study of the use of innovating magnetic sensors in eddy current non destructive inspection. The author reports an analysis survey of magnetic sensor performances. This survey enables the selection of magnetic sensor technologies used in non destructive inspection. He presents the state-of-the-art of eddy current probes exploiting the qualities of innovating magnetic sensors, and describes the methods enabling the use of these magnetic sensors in non destructive testing. Two main applications of innovating magnetic sensors are identified: the detection of very small defects by means of magneto-resistive sensors, and the detection of deep defects by means of giant magneto-impedances. Based on the use of modelling, optimization, signal processing tools, probes are manufactured for these both applications.

2007-06-15

76

Read Code Quality Assurance  

UK PubMed Central (United Kingdom)

As controlled clinical vocabularies assume an increasing role in modern clinical information systems, so the issue of their quality demands greater attention. In order to meet the resulting stringent...Full Text Available

1998-07-01

77

High quality water supply system; Joshitsusui kyokyu system  

Energy Technology Data Exchange (ETDEWEB)

This paper, firstly, introduces the background in developing a high quality water supply system, in which the drinking water system is isolated inside a building. Results of questionnaire on the high quality service water are illustrated. The results of questionnaire have revealed that the high quality service water is extremely interested. Then, are described the target quality of high quality water, the constitution of high quality water supply system, the treatment process, the measures to secure safety and sanitary, and the method of maintenance. The high quality water is produced through the activated charcoal absorption treatment, membrane treatment, ozonation, cooling, mineral addition, and disinfection of city water. Furthermore, application examples of this ...

1995-01-15

78

Pipeline integrity inspections  

Energy Technology Data Exchange (ETDEWEB)

The conference paper gives a short description of the strategies within Statoil Gas Transport for pipeline condition monitoring and control. This is done for ensuring that the pipeline integrity can be maintained during all phases from construction to operation. Efficient condition monitoring and control can only be performed if the total pipeline integrity is taken into consideration such as design conditions, experience, environmental information, and general improved knowledge or the like for determining the requirement of inspection. Such philosophy will ensure the pipeline integrity better as corrective actions can be taken at a very early stage before any damage to the pipeline system have developed. 1 fig.

1995-12-31

79

Energy Savings Modeling and Inspection Guidelines for Commercial Building Federal Tax Deductions, Second Edition  

Energy Technology Data Exchange (ETDEWEB)

This document provides guidance for modeling and inspecting energy-efficient property in commercial buildings for certification of the energy and power cost savings related to Section 179D of the Internal Revenue Code enacted in Section 1331 of the 2005 Energy Policy Act and noted in Internal Revenue Service Notice 2006-52. Specifically, Section 179D provides federal tax deductions for energy-efficient property related to a commercial building's envelope; interior lighting; heating, ventilating, and air conditioning; and service hot water systems.

2007-05-01

80

Energy Savings Modeling and Inspection Guidelines for Commercial Building Federal Tax Deductions  

Energy Technology Data Exchange (ETDEWEB)

This document provides guidance for modeling and inspecting energy-efficient property in commercial buildings for certification of the energy and power cost savings related to Section 179D of the Internal Revenue Code enacted in Section 1331 of the 2005 Energy Policy Act and noted in Internal Revenue Service Notice 2006-52. Specifically, Section 179D provides federal tax deductions for energy-efficient property related to a commercial building's envelope; interior lighting; heating, ventilating, and air conditioning; and service hot water systems.

2007-02-01

81

Annual Report 2007. Nuclear Regulatory Authority  

International Nuclear Information System (INIS)

The present Annual Report of Activities of the Nuclear Regulatory Authority (ARN), prepared regularly from the creation as independent institution, describes across tree parts and seven annexes the activities developed by the organism during 2007. The main topic are: the organization and the activity of the ARN; the regulatory standards; the licensing and inspection of nuclear power plants and critical facilities; the emergency systems; the occupational surveillance; the environmental monitoring; improved organizational. Also, this publication have annexes with the following content: regulatory documents; inspections to medical, industrial and training installations; regulatory guides; measurement and evaluation of the drinking water of Ezeiza.

2004-07-11

82

`Procurement quality engineering`: A measurement driven system to assure quality at each step in the procurement process  

Energy Technology Data Exchange (ETDEWEB)

The `Procurement Quality Function` is an element of the Body of Knowledge of Quality Engineering, as defined by the American Society for Quality Control (ASQC). This paper describes the Procurement Quality function which has been installed as an integral part of the Quality Engineering group of the Technical and Management Support Services (T&MSS) contractor to the United States Department of Energy (DOE) Yucca Mountain Site Characterization Project. Each of the elements of the T&MSS Procurement Quality Engineering (PQE) system is discussed along with the measurements obtained. With the installation and development of the PQE system we have attained more meaningful evaluation of supplier capability, reduction of procurement document review reject ratios from 31% to less than 2% per quarter, more effective ...

1993-12-31

83

Development of Guide System for a Reactor Head Maintenance Robot  

Energy Technology Data Exchange (ETDEWEB)

The Control Rod Drive(CRD) nozzles for PWR nuclear power plants(NPP) house the control rod drives. The number of nozzle penetrations range from the mid-30's to over 100 in each reactor head. The integrity of CRD nozzles is very important, because the primary pressure boundary is established with the J-groove weld joining the nozzle to the head clad surface. The Alloy 600 PWSC CRD nozzle leaks discovered in the fall of 2000 and spring of 2001 in several US plants. Therefore the NRC has recommended a more proactive effort by US utilities to inspect similarly susceptible nozzles in all US plants. The primary safety concern is circumferential cracks that can permit the nozzles to separate from the head at high velocity and produce a large-break leak in the reactor vessel. A secondary concern is head leakage from any through-wall cracks in the nozzle or J-groove weld area. Numerous inspection and repair tools have been developed to address ...

2005-07-01

84

Demonstration of mobile accelerator neutron radiography for in situ detection of moisture and corrosion in aircraft structures  

Energy Technology Data Exchange (ETDEWEB)

A demonstration of the first mobile 'on-off' neutron radiography system, developed by Vought Corporation Advanced Technology Center, has been conducted at McClellan Air Force Base. On-site neutron radiography operations with the engineering model were carried out to demonstrate the potential of such a system for in situ detection of hidden moisture and corrosion in aircraft structures, and to assess the performance of the unique hardware system in a depot environment. Inspections were performed on F-111 and F-106 aircraft, and several structures removed from T-39 and A-10 aircraft were also inspected. The effectiveness of the new N-ray system for imaging moisture and corrosion was confirmed after subsequent removal of skins from some of the F-111 structures. Excellent correlation of radiographic images with actual moisture and corrosion damage ...

1983-01-01

85

Safety and exploitation of dams: quality approach for the control of dams in Drire Provence-Alpes-Cote-d'Azur. Dams life. Activities of the control services; Securite et exploitation des barrages: demarche qualite pour le controle des barrages en Drire Provence-Alpes-Cote-d'Azur. La vie des barrages. Activites des services du controle  

Energy Technology Data Exchange (ETDEWEB)

This issue of Barrages newsletter comprises three articles. The first article treats of the quality approach relative to the organization of the inspections of big and medium size dams. It summarizes the improvements of this approach added in 2003 after analysis of the experience feedback. The second article presents the conclusions of the decennial and annual inspections of dams in exploitation. Only the observations requiring a special follow-up are reported. The last article summarizes the activities of the control services for the third quarter of 2003: decennial and annual visits, important facts, administrative instructions, studies, projects and works, organization of services, technical studies etc.. (J.S.)

2003-07-01

86

Explosives detector  

Energy Technology Data Exchange (ETDEWEB)

An apparatus for non-invasively inspecting an object, such as an item of luggage, for explosives material is described. It comprises a multi-channel thermal neutron inspection system having a plurality of neutron irradiation chambers. Simultaneous operation of several channels increases the maximum system throughput several times. Each chamber has a lithium neutron source which is stimulated to neutron production by a proton beam. Beam switching magnets are energised by pulsing to divert a common proton beam to each source in turn. The initial beam is generated by a radio frequency quadrupole accelerator. The advantages of this system are very low residual source activity and controllable neutron production thereby minimising safety hazards. The irradiation chamber may contain several different gamma ray detectors to identify the elements present in explosives material. In addition, ...

1991-10-02

87

Fuzzy theory applied in quality management of distributed manufacturing system: A literature review and classification  

British Library Electronic Table of Contents (United Kingdom)

Fuzzy theory has been regarded as a very important technique for quality management (QM) of distributed manufacturing system and attracts the attentions of academic and industry; however, there is a lack of a comprehensive literature review and a classification scheme for it. This paper is the first academic literature review of the fuzzy theory applied in quality management of distributed manufacturing system. It involves five most popular databases in this research area and covers more than 20 journals, proposes a classification scheme using clustering analysis method. Sixty-one journal articles were finally selected, reviewed and classified. Each selected article was classified firstly based on four QM dimensions (quality planning, quality control, quality assurance and quality improvem...

2011-01-01

88

Eddy current signal analysis techniques for assessing degradation of support plate structures in nuclear steam generators  

Energy Technology Data Exchange (ETDEWEB)

The steam generator (SG) is one of the most critical components of the heat transfer system in nuclear generation stations. Testing the structural integrity of SG tubing and SG internals is a key element of the fitness-for-service assessments to assure the safe and continuous operation of nuclear power plants. Recent eddy current (ET) inspections of two nuclear power plants revealed degradation of some of the tube support plate (TSP) structures, which was also confirmed by visual inspection. The phenomena was described as metal loss, caused by flow-accelerated corrosion of the carbon steel trefoil support plate and varying from minor to complete loss of the ligaments. This loss of TSP ligaments results in lack of support for the adjacent tubes making them more susceptible to fretting-wear damage and fatigue cracking. A signal analysis method, based on the responses at low frequency of two types of eddy current probes, has ...

2006-07-01

89

United States Domestic Research Reactor Infrastrucutre TRIGA Reactor Fuel Support  

Energy Technology Data Exchange (ETDEWEB)

The United State Domestic Research Reactor Infrastructure Program at the Idaho National Laboratory manages and provides project management, technical, quality engineering, quality inspection and nuclear material support for the United States Department of Energy sponsored University Reactor Fuels Program. This program provides fresh, unirradiated nuclear fuel to Domestic University Research Reactor Facilities and is responsible for the return of the DOE-owned, irradiated nuclear fuel over the life of the program. This presentation will introduce the program management team, the universities supported by the program, the status of the program and focus on the return process of irradiated nuclear fuel for long term storage at DOE managed receipt facilities. It will include lessons learned from research reactor facilities that have successfully shipped spent fuel elements to DOE receipt facilities.

2011-03-01

90

Characteristics Testing of the ECT Bobbin Probe for S/G Tube Inspection  

Energy Technology Data Exchange (ETDEWEB)

The bobbin probe technique is basically one of the important ECT methods for the steam generator tube integrity assessment that is practiced during each plant outage. The bobbin probe also is the essential component which consists of the whole ECT examination system, and provides a decisive data for the evaluation of tube integrity in compliance with acceptance criteria described in specific procedures. The selection of probe is especially important because the quality of acquired ECT data is determined by the probe design characteristics, such as geometry and operation frequency, and has an important effect on examination results. The Electric Power Research Institute (EPRI) has recently defined the procedures for the qualification of eddy current hardware and technique. These procedures provide two basic methods for qualification. Flawed tube removed from operation, or artificial flaw is required for the original qualification of technique ...

2010-05-15

91

Characteristics Testing of the ECT Bobbin Probe for S/G Tube Inspection  

International Nuclear Information System (INIS)

The bobbin probe technique is basically one of the important ECT methods for the steam generator tube integrity assessment that is practiced during each plant outage. The bobbin probe also is the essential component which consists of the whole ECT examination system, and provides a decisive data for the evaluation of tube integrity in compliance with acceptance criteria described in specific procedures. The selection of probe is especially important because the quality of acquired ECT data is determined by the probe design characteristics, such as geometry and operation frequency, and has an important effect on examination results. The Electric Power Research Institute (EPRI) has recently defined the procedures for the qualification of eddy current hardware and technique. These procedures provide two basic methods for qualification. Flawed tube removed from operation, or artificial flaw is required for the original qualification of technique ...

2010-05-01

92

Chalon/Saint-Marcel manufacturing plant; L'usine de Chalon/Saint-Marcel  

Energy Technology Data Exchange (ETDEWEB)

AREVA is the world leader in the design and construction of nuclear power plants, the manufacture of heavy components, and the supply of nuclear fuel and nuclear services such as maintenance and inspection. The Equipment Division provides the widest range of nuclear components and equipment, manufactured at its two facilities in Jeumont, northern France, and St. Marcel, in Burgundy. The St. Marcel plant, set on 35 ha (87.5 acres) near Chalon-sur-Saone, was established in 1973 in a region with a long history of specialized metalworking and mechanical activities to meet the demand for non-military nuclear requirements in France. The site offers two advantages: - excellent facilities for loading and transporting heavy components on the Saone river, - it's proximity to other group sites. Since its completion in 1975, the Chalon/St. Marcel facility has manufactured all the heavy components for French pressurized water reactors (PWRs) ranging from 900 MW to 1500 ...

2008-07-01

93

Korea-IAEA Unattended Safeguards Approach on the Spent Fuel Transfer to Dry Storage in Wolsung NPP  

Energy Technology Data Exchange (ETDEWEB)

The field trial of an unattended monitoring system for SF transfer verification ended in June 2005. The system is aiming to improve the safeguards measures applied during SF transfers and reduce inspection effort currently required by the Operator, NNCA and the IAEA. They were reviewed based on its technical performance and other issues in this paper.

2006-07-01

94

Korea-IAEA Unattended Safeguards Approach on the Spent Fuel Transfer to Dry Storage in Wolsung NPP  

International Nuclear Information System (INIS)

The field trial of an unattended monitoring system for SF transfer verification ended in June 2005. The system is aiming to improve the safeguards measures applied during SF transfers and reduce inspection effort currently required by the Operator, NNCA and the IAEA. They were reviewed based on its technical performance and other issues in this paper.

2006-05-25

95

Detection of drugs and explosives using neutron computerized tomography and artificial intelligence techniques  

International Nuclear Information System (INIS)

In this study the development of a methodology to detect illicit drugs and plastic explosives is described with the objective of being applied in the realm of public security. For this end, non-destructive assay with neutrons was used and the technique applied was the real time neutron radiography together with computerized tomography. The system is endowed with automatic responses based upon the application of an artificial intelligence technique. In previous tests using real samples, the system proved capable of identifying 97% of the inspected materials.

2010-06-01

96

Analysis of chlorinated polyvinyl chloride pipe burst problems :Vasquez residence system inspection.  

Energy Technology Data Exchange (ETDEWEB)

This report documents the investigation regarding the failure of CPVC piping that was used to connect a solar hot water system to standard plumbing in a home. Details of the failure are described along with numerous pictures and diagrams. A potential failure mechanism is described and recommendations are outlined to prevent such a failure.

2005-10-01

97

A novel gamma scanning system for on-line diagnostic inspection of industrial process columns  

International Nuclear Information System (INIS)

A computerised gamma scanning facilities for on-line investigation of industrial process columns and vessels has been developed by the Malaysian Nuclear Agency (Nuclear Malaysia). The technology, based on the principle of gamma-ray absorption, has been successfully applied for real-time troubleshooting, process investigation and predictive maintenance of a number of distillation columns and process vessels in petroleum refineries, gas processing plants and chemical plants in the country and the surrounding region. This paper outlines basic characteristics of the system and describes the inspection procedures, and in addition, presents a number of case studies. The case studies are purposely chosen to illustrate the versatility of the technology, and furthermore to demonstrate the economic benefits which can be realised from the application of this technology. (Author)

98

Quality assurance requirements in various codes and standards  

International Nuclear Information System (INIS)

The quality assurance requirements in various countries and according to various international codes and standards are presented, compared and critically discussed. Cases of developing countries are also discussed, and the use of IAEA code of practice and other codes for quality assurance in these countries is reviewed. Recommendations are made regarding the quality assurance system to be applied for Egypt's nuclear power plants.

99

Applications of a downhole programmable microprocessor for a geothermal borehole inspection tool  

Energy Technology Data Exchange (ETDEWEB)

The high-temperature scanning borehole inspection system is currently being developed jointly by the Los Alamos National Laboratory (LANL) and Westfalische Berggewerkschaftskasse (WBK) of West Germany. The downhole instrument is a digital televiewer that utilized a microprocessor to digitize, process and transmit the acoustic information to the surface acquisition and control system. The primary operation of the downhole acoustic assembly uses a piezoelectric crystal acting as a receiver-transmitter which is mounted on the rotating head. The crystal emits a burst of acoustic energy that propagates through the borehole fluid with a portion of the energy reflected by the borehole wall back to the crystal. The time of travel and the amplitude of the reflected signal are conditioned by the microprocessor and transmitted along with other pertinent data to the surface data processing center. This instrument has been designed ...

1987-01-01

100

Long-term preventive maintenance of instrumentation control equipment for PWR plants  

International Nuclear Information System (INIS)

Since the PWR plants in Japan have been operated more than 30 years, main instrumentation control equipment of analog systems has been renewed to digital control systems. Renewal works had to be done in short period within periodical inspection term and for several facilities. The Mitsubishi LTD group had been provided with these market needs by its digital control system (MELTAC-NplusR 3) applicable to main instrumentation control equipment for primary and secondary systems and had already finished the renewal for practical plants. (T. Tanaka)

2006-02-01

101

Implantation of an electronic system for real time neutron graphic images acquisition at the IPEN/CNEN Argonaut reactor  

International Nuclear Information System (INIS)

The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)

2004-04-01

102

Artificial intelligence: the future in nuclear plant maintenance  

Energy Technology Data Exchange (ETDEWEB)

The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.

1984-12-01

103

Artificial intelligence: the future in nuclear plant maintenance  

International Nuclear Information System (INIS)

The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.

1984-09-23

104

30 CFR 77.1606 - Loading and haulage equipment; inspection and maintenance.  

Science.gov (United States)

...2010-07-01 false Loading and haulage equipment; inspection and maintenance... § 77.1606 Loading and haulage equipment; inspection and maintenance. (a) Mobile loading and haulage equipment shall be inspected by a...

2010-07-01

105

Safety performance indicators. Topical issues paper no. 5  

International Nuclear Information System (INIS)

Since its creation the nuclear industry has been struggling with the question of how safe is safe enough. Safety is a common goal to all involved in the design, operation and regulation of a nuclear installation. As a concept safety is not easy to define. However, there is a general understanding of what attributes a nuclear power plant should have in order to operate safely. The challenge lies in measuring the attributes. The new competitive open electricity market, in many countries throughout the world, is increasing the economic pressure on operators to lower operating costs without jeopardizing safety. Challenges are occurring at a rate that is unprecedented in the nuclear industry: competitiveness; downsizing; ageing; policy changes; reorganization; restructuring; mergers; globalization; and takeovers demand increasing attention to the management of safety. There are various means to measure safety performance, some of which are more qualitative in nature and others which through ...

2001-09-03

106

How to start a utility TQM program  

Energy Technology Data Exchange (ETDEWEB)

Huntsville, Alabama Utilities has successfully provided services for over 53 years. However, the quality of service demands from customers are changing every day! Part of this demand is due to updated digital appliances, home and business computers, and automated systems. A quality program was initiated in 1992 as a result of an internal assessment. The Malcolm Baldrige approach was selected which includes seven areas: (1) Leadership; (2) Information and Analysis; (3) Strategic Planning; (4) Human Resource Utilization; (5) Quality Assurance of Products and Services: (6) Quality Results: (7) Customer Satisfaction. Training for and implementation of the Quality program is discussed in detail.

1994-12-31

107

Improving the Quality of Life  

Wastenet

...and supply ensuring better food quality for the consumer developing safer and more flexible food production processes and technologies raw materials for food production; production and processing systems; by-products and wastes from fisheries and agro-industry; new food sources; packaging systems; quality monitoring; traceability Food contamination detecting and eliminating infectious and toxic agents throughout the food chain establishing the hazards and origins of food contaminants producing food more safely rapid ...

108

Transmit-receive eddy current probes  

International Nuclear Information System (INIS)

In the last two decades, due to increased inspection demands, eddy current instrumentation has advanced from single-frequency, single-output instruments to multifrequency, computer-aided systems. This has significantly increased the scope of eddy current testing, but, unfortunately, it has also increased the cost and complexity of inspections. In addition, this approach has not always improved defect detectability or signal-to-noise. Most eddy current testing applications are still performed with impedance probes, which have well known limitations. However, recent research at AECL has led to improved eddy current inspections through the design and development of transmit-receive (T/R) probes. T/R eddy current probes, with laterally displaced transmit and receive coils, present a number of advantages over impedance probes. They have improved signal-to-noise ratio in the presence of variable lift-off ...

1997-10-27

109

Real time neutron radioscopy - trends and applications  

International Nuclear Information System (INIS)

Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor

2003-11-12

110

The Experience of Cooperation with IAEA new approach for Spent Fuel Transfer Campaign at CANDU Reactors  

Energy Technology Data Exchange (ETDEWEB)

It was agreed that both of the Republic Of Korea (ROK) and the International Atomic Energy Agency (IAEA) cooperate with the new approach using the Unattended Monitoring Systems (UMS), the mailbox declaration and the short notice inspections, which can decrease the agency inspection efforts and operator' s burden. As a result of the positive cooperation of ROK for applying new approach, the IAEA could accomplish a successful implementation of new safeguards approach during last transfer campaigns at Wolsung site. As of the end of Feb. 2007, the IAEA installed the UMS at Wolsung units 2, 3 and 4. The transfer campaigns at Wolsung units 2 and 4 are performing from April, 2007. The IAEA will install the UMS at Wolsung unit 1 by the end of 2007. Then agency will inspect all of transfer campaign at Wolsung units by using new approach with UMS, mailbox declaration and SNI. It is based on the SSAC full ...

2007-07-01

111

The Experience of Cooperation with IAEA new approach for Spent Fuel Transfer Campaign at CANDU Reactors  

International Nuclear Information System (INIS)

It was agreed that both of the Republic Of Korea (ROK) and the International Atomic Energy Agency (IAEA) cooperate with the new approach using the Unattended Monitoring Systems (UMS), the mailbox declaration and the short notice inspections, which can decrease the agency inspection efforts and operator' s burden. As a result of the positive cooperation of ROK for applying new approach, the IAEA could accomplish a successful implementation of new safeguards approach during last transfer campaigns at Wolsung site. As of the end of Feb. 2007, the IAEA installed the UMS at Wolsung units 2, 3 and 4. The transfer campaigns at Wolsung units 2 and 4 are performing from April, 2007. The IAEA will install the UMS at Wolsung unit 1 by the end of 2007. Then agency will inspect all of transfer campaign at Wolsung units by using new approach with UMS, mailbox declaration and SNI. It is based on the SSAC full ...

2007-05-10

112

Underground piping handbook  

Energy Technology Data Exchange (ETDEWEB)

This book provides the information required to design and prepare construction drawings, and to install, inspect, test, and commission buried piping. Both pressure and gravity piping are covered, including water, steam, gases, and sewers. Directed primarily toward underground industrial piping systems, this is a succinct, well-organized compilation of practical knowledge. Checklists, examples, tables, charts, nomographs, short cuts, and helpful hints gained through years of experience complete this timely and useful ''how to'' book.

1985-01-01

113

Pipe crawlers  

International Nuclear Information System (INIS)

The patent concerns pipe crawlers, i.e. apparatus capable of moving along the bores of pipes and tubes. Pipe crawlers are employed for conveying inspection equipment along the bores of pipes and tubes. The pipe crawler comprises a piston and assembly system, which controls the movement of the crawler and supports the assembly centrally within the bore of the pipe or tube. (UK).

1984-11-29

114

Micromachining using focused ion beams  

Energy Technology Data Exchange (ETDEWEB)

Focused ion beam (FIB) systems prove to be useful precision micromachining tools for a wide variety of applications. This micromachining technique includes scanning ion microscopy (SIM), micromachining by physical sputtering, and the ion-beam induced surface chemistry for etching and deposition. This technique is applied to image and modify IC's, to micromechanical applications, to modify the tip shape of tungsten emitters, and to prepare cross sections of selected regions for inspection in a transmission electron microscope (TEM). (orig.)

1994-11-16

115

Improving airport explosives detection  

Energy Technology Data Exchange (ETDEWEB)

ORNL has developed the technology to detect hidden explosives in luggage using X ray and neutron detection devices. The Federal Aviation Administration has ordered the airlines to buy and install Thermal Neutron Analysis (TNA) units. The combined pulsed-neutron and X-ray interrogation inspection (CPNX) system developed at ORNL uses less radioactive materials as well as being more sensitive to weapons, electronic devices and plastic explosives.

1990-01-01

116

A tube inspection device. Dispositif de controle de tubes  

Energy Technology Data Exchange (ETDEWEB)

The device, aimed at non destructive control of the inner side of tubes such as steam generator tubes, is composed of a control sensor mounted on a support; the sensor head may rotate in the tube and a measuring system and signal processing allow for the exact determination of the angular position of the sensor head (application to ultrasonic or eddy current probes).

1993-05-07

117

Integrated thermal and nonthermal treatment technology and subsystem cost sensitivity analysis  

Energy Technology Data Exchange (ETDEWEB)

The U.S. Department of Energy`s (DOE) Environmental Management Office of Science and Technology (EM-50) authorized studies on alternative systems for treating contact-handled DOE mixed low-level radioactive waste (MLLW). The on-going Integrated Thermal Treatment Systems` (ITTS) and the Integrated Nonthermal Treatment Systems` (INTS) studies satisfy this request. EM-50 further authorized supporting studies including this technology and subsystem cost sensitivity analysis. This analysis identifies areas where technology development could have the greatest impact on total life cycle system costs. These areas are determined by evaluating the sensitivity of system life cycle costs relative to changes in life cycle component or phase costs, subsystem costs, contingency allowance, facility capacity, operating life, and disposal costs. For all treatment systems, the ...

1997-02-01

118

Supply of medium and small hydropower equipment  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a brief account of Lingling Hydroelectric Power Equipment General Works, the capacity of equipment production, the organization body, the quality assurance system and supervision of government department on its product quality.

1995-07-01

119

A predictive model of Health Related Quality of life of parents of chronically ill children: the importance of care-dependency of their child and their support system  

UK PubMed Central (United Kingdom)

BackgroundParents of chronically ill children are at risk for a lower Health Related Quality of Life (HRQoL). Insight in the dynamics of factors influencing parental HRQoL is necessary...Full Text Available

120

The development of automatic surface dose-rate measuring and recording system for radioactive waste drum  

International Nuclear Information System (INIS)

The system which is performed the transportation and measurement of drum automatically to measure the surface dose-rate of radioactive waste drum and can inspect place of contaminated sources and precise dose-rate within a drum according to measuring many places equally at the same time has been developed. It is expected that the system be used to minimized radiation exposure of workers and manage the drum effectively according to established at the production facilities as well as the radioactive waste treatment facilities. (author). 7 refs., 9 tabs., 16 figs.

121

Development of radioimmunometric assays and kits for non-clinical applications. Proceedings of a final research coordination meeting  

International Nuclear Information System (INIS)

Immunoassays are versatile analytical techniques that had a leading role in various clinical applications, during the last four decades. The studies carried out by Rosalyn Yalow, Solomon Berson and Roger Ekins in the 1960s gave a breakthrough in the development of this novel analytical method. Sensitivity up to femtomolar concentrations, high specificity and universal application to different classes of molecular species made immunoassay a very useful tool in analytical investigation. The expertise acquired by immunochemists in producing antibodies against any antigen and the ability of radiochemists in labeling the antigens with "1"2"5I without affecting the active site are the two main factors responsible for the above development. There are concerns about the safety and health of humans due to the high-level contamination of environment by pesticides, industrial compounds and metals, anabolic steroids in milk and meat products, and presence of mycotoxins in food and feed ...

2004-12-06

122

Review of UCN 3,4 PSA model based on NEI PRA peer review process guidance, rev.0  

International Nuclear Information System (INIS)

Recently, under the de-regulation environment, nuclear industry has attempted various approaches to improve the economics of Nuclear Power Plants (NPP). One of these efforts is the Risk Informed/Performance-Based Operation (RIPBO). This approach uses the risk and performance information to manage the resources effectively and efficiently that are used in the operation of NPP. In RIPBO, PSA quality is one of the most important things. The nuclear industry and regulatory body of U.S.A have developed a measure to evaluate the quality of PSA. NEI (Nuclear Energy Institute) has developed a guidance called 'NEI PRA Peer Review Guidance,' and NRC (Nuclear Regulatory Committee) and ASME have developed the 'PRA Standard.' In Korea, several projects are on going now, such as the extension of AOT/STI of RPS/ESFAS, Risk-Informed In-Service Inspection (RI-ISI). However, in Korea, there have been no attempts to evaluate the ...

2004-10-03

123

Review of UCN 3,4 PSA model based on NEI PRA peer review process guidance, rev.0  

Energy Technology Data Exchange (ETDEWEB)

Recently, under the de-regulation environment, nuclear industry has attempted various approaches to improve the economics of Nuclear Power Plants (NPP). One of these efforts is the Risk Informed/Performance-Based Operation (RIPBO). This approach uses the risk and performance information to manage the resources effectively and efficiently that are used in the operation of NPP. In RIPBO, PSA quality is one of the most important things. The nuclear industry and regulatory body of U.S.A have developed a measure to evaluate the quality of PSA. NEI (Nuclear Energy Institute) has developed a guidance called 'NEI PRA Peer Review Guidance,' and NRC (Nuclear Regulatory Committee) and ASME have developed the 'PRA Standard.' In Korea, several projects are on going now, such as the extension of AOT/STI of RPS/ESFAS, Risk-Informed In-Service Inspection (RI-ISI). However, in Korea, there have been no ...

2003-05-01

124

Review of UCN 3,4 PSA model based on ASME PRA standard rev.0  

International Nuclear Information System (INIS)

Recently, under the de-regulation environment, nuclear industry has attempted various approaches to improve the economics of Nuclear Power Plants (NPP). One of these efforts is the Risk Informed/Performance-Based operation (RIPBO). This approach uses the risk and performance information to manage the resources effectively and efficiently that are used in the operation of NPP. In RIPBO, PSA quality is one of the most important things. The nuclear industry and regulatory body of U.S.A have developed a measure to evaluate the quality of PSA. NEI (Nuclear Energy Institute) has developed a guidance called 'NEI PRA Peer Review Guidance,' and NRC (Nuclear Regulatory Committee) and ASME have developed the 'PRA Standard.' In Korea, several projects are on going now, such as the extension of AOT/STI of RPS/ESFAS, Risk-Informed In-Service Inspection (RI-ISI). However, in Korea, there have been no attempts to evaluate the ...

2011-03-13

125

Review of UCN 3,4 PSA model based on ASME PRA standard rev.0  

Energy Technology Data Exchange (ETDEWEB)

Recently, under the de-regulation environment, nuclear industry has attempted various approaches to improve the economics of Nuclear Power Plants (NPP). One of these efforts is the Risk Informed/Performance-Based operation (RIPBO). This approach uses the risk and performance information to manage the resources effectively and efficiently that are used in the operation of NPP. In RIPBO, PSA quality is one of the most important things. The nuclear industry and regulatory body of U.S.A have developed a measure to evaluate the quality of PSA. NEI (Nuclear Energy Institute) has developed a guidance called 'NEI PRA Peer Review Guidance,' and NRC (Nuclear Regulatory Committee) and ASME have developed the 'PRA Standard.' In Korea, several projects are on going now, such as the extension of AOT/STI of RPS/ESFAS, Risk-Informed In-Service Inspection (RI-ISI). However, in Korea, there have been no ...

2003-05-01

126

Review of KSNP LPSD PSA model based of ANS LPSD PRA standard, rev.0  

Energy Technology Data Exchange (ETDEWEB)

Recently, under the de-regulation environment, nuclear industry has attempted various approaches to improve the economics of Nuclear Power Plants (NPP). One of these efforts is the Risk Informed/Performance-based Operation (RIPBO). This approach uses the risk and performance information to manage the resources effectively and efficiently that are used in the operation of NPP. In RIPBO, PSA quality is one of the most important things. The nuclear industry and regulatory body of U.S.A have developed a measure to evaluate the quality of PSA. NEI (Nuclear Energy Institute) has developed a guidance called 'NEI PRA Peer Review Guidance,' and NRC (Nuclear Regulatory Committee) and ASME have developed the 'PRA Standard.' In Korea, several projects are on going now, such as the extension of AOT/STI of RPS/ESFAS, Risk-informed In-service Inspection (RI-ISI). However, in Korea, there have been no ...

2004-02-01

127

The influence of scattered radiation on recording systems and quality-assurance test parameters  

International Nuclear Information System (INIS)

Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).

1988-02-23

128

The influence of scattered radiation on recording systems and quality-assurance test parameters  

International Nuclear Information System (INIS)

Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).

129

The upgrade of nuclear material accounting system at KAERI  

International Nuclear Information System (INIS)

The agreement between the government of Republic Of Korea (ROK) and the IAEA for the application of safeguards was signed and entered into force in 1975. The Additional Protocol (AP) to the Safeguards Agreement between the ROK and the IAEA was signed in 1999 and entered into force on 19 February 2004. Also, Implementation of Integrated Safeguards (IS) was started on 1 July, 2008 after a draw of the broader conclusion. The IAEA provides 2 hours notification for Random Interim Inspection (RII) under IS. For RII, the facility has to prepare the inspection documents in a short time. Therefore, KAERI (Korea Atomic Energy Research Institute) developed a new computerized nuclear material accounting system named KASIS (KAERI Safeguards Information treatment System) to treat the data by on-line for RII. For the efficient IS implementation, KAERI has a plan to upgrade the system to reflect ...

2010-10-01

130

Improving radiotherapy quality and safety: a common objective of A.S.N. and the Ile de France Regional Hospital Agency. Thoughts on successful cooperation in Ile de France; Ameliorer la qualite et la securite de la radiotherapie: un objectif conjoint de l'A.S.N. et de l'Agence regionale de l'hospitalisation Ile de France. Reflexions sur une cooperation feconde en Ile de France  

Energy Technology Data Exchange (ETDEWEB)

Radiotherapy recent development in cancer treatment needs strong procedures and quality assessment to improve safety both for patients and professionals. In Ile de France territory, a coordinated action between ASN inspectors and medical doctors specialized in public health (MISP), working as civil servants in health administration, was initiated at the end of 2007. An inspection guideline was implemented in a workshop between ASN and Regional Hospital Agency (ARH). The MISP as health administrator has to verify if care organisation responds to treatment cancer regulatory framework: as a doctor he is authorized to access to patient records to know which treatment was chosen. He has to assure if the therapeutic guidelines are respected. His comprehensive approach is essentially patient-oriented. The MISP inspection coordinated with ASN inspectors is a very pertinent pluri-disciplinary approach, undeniably necessary in such a ...

2009-02-15

131

Improving radiotherapy quality and safety: a common objective of A.S.N. and the Ile de France Regional Hospital Agency. Thoughts on successful cooperation in Ile de France  

International Nuclear Information System (INIS)

Radiotherapy recent development in cancer treatment needs strong procedures and quality assessment to improve safety both for patients and professionals. In Ile de France territory, a coordinated action between ASN inspectors and medical doctors specialized in public health (MISP), working as civil servants in health administration, was initiated at the end of 2007. An inspection guideline was implemented in a workshop between ASN and Regional Hospital Agency (ARH). The MISP as health administrator has to verify if care organisation responds to treatment cancer regulatory framework: as a doctor he is authorized to access to patient records to know which treatment was chosen. He has to assure if the therapeutic guidelines are respected. His comprehensive approach is essentially patient-oriented. The MISP inspection coordinated with ASN inspectors is a very pertinent pluri-disciplinary approach, undeniably necessary in such a ...

2009-02-01

132

Results of regular inspection of No.2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc  

International Nuclear Information System (INIS)

The regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from January 7 to February 8, 1985. The summary of the results of this regular inspection is as follows. The facilities as the object of inspection were radiation control facilities and waste facilities. On these facilities as the object of inspection, the appearance, disassembling, functional, performance and other inspections were carried out, and as the results, abnormality was not found at all. The works related to this regular inspection were accomplished within the range of the allowable radiation dose based on the relevant laws. (Kako, I.).

1986-01-01

133

Special phased array applications for pipeline girth weld inspections  

Energy Technology Data Exchange (ETDEWEB)

Pipeline automated ultrasonic testing (AUT) uses fully automated equipment that travels around a pipe on a welding band in a linear scan to allow array pulses to provide ultrasound information on weld zones. Pipeline AUT is also used for zone discrimination as well as with special calibration blocks, dual gate output displays, and rapid defect sizing. AUT allows for the inspection of welds soon after completion, and can save construction costs by process control when combined with engineering critical assessment (ECA) to minimize rejection rates. Ultrasonic phased arrays (UPA) use an array of elements that are all individually wired, pulsed, and time-shifted. Elements are pulsed in groups of approximately 16 elements at a time for pipeline welds. Phased arrays can be used to combine electronic scanning, sectorial scanning and precision focusing to give a practical combination of displays. Optimum angles can be selected for welds and other components, and the ...

2004-07-01

134

Experience in complying with quality assurance requirements for cask lifting devices  

International Nuclear Information System (INIS)

The Nuclear Assurance Corporation (NAC) owns and operates four NAC-1 truck casks. These casks are used to ship spent reactor fuel assemblies and radioactive reactor-core components. The casks have been loaded or unloaded at a total of fifteen nuclear facilities in the United States. In addition, NAC has used another large, overweight-truck cask to ship radioactive reactor core components from a reactor to a waste burial site. There are many individual differences in the cask handling facilities at each of the reactor stations, nuclear research facilities and the storage and burial sites serviced. Various types of auxiliary lifting and handling devices for on-site cask operations have been required. The quality assurance requirements for the equipment used in interfacing casks with nuclear power plant facilities have become more stringent. This paper presents details on the type of special equipment being employed, the quality assurance ...

135

Materials Research Related to W-band Cavity Construction  

Energy Technology Data Exchange (ETDEWEB)

Low power rf measurements, S11, of electro-discharge machined (EDM) diffusion bonded mm-wave traveling wave rf cavities were not in satisfactory agreement with electromagnetic simulations. During subsequent mechanical inspection, the cell-to-cell iris were found to be distorted. This led to a series of systematic experiments to study the mechanical properties of oxygen free high conductivity Copper (OFHC) and Glidcop AL-15. Results of these studies which include cell-to-cell iris distortion, EDM machining accuracies, surface quality, and the results of different bonding techniques are presented. The results of our mechanical studies are used to develop a set of mechanical design constraints for a second series of constant impedance W-Band structures that also used wire EDM and high temperature bonding for their manufacture.

2000-10-18

136

Learning material defect patterns by separating mixtures of independent component analyzers from NDT sonic signals  

British Library Electronic Table of Contents (United Kingdom)

This paper introduces the application of independent component analysis mixture modelling (ICAMM) in non-destructive testing (NDT). The application consists of discriminating patterns for material quality control from homogeneous and defective materials inspected by impact-echo testing. This problem is modelled as a mixture of independent component analysis (ICA) models, representing a class of defective or homogeneous material by an ICA model whose parameters are learned from the impact-echo signal spectrum. These parameters define a kind of particular signature for the different defects. The proposed procedure is intended to exploit to the maximum the information obtained with the cost efficiency of only a single impact. To illustrate this capability, four levels of classification detail...

2010-01-01

137

IGC'97: highlights  

International Nuclear Information System (INIS)

The IGC Highlights briefly outlines some of the the significant progresses made by Indira Gandhi Centre for Atomic Research, Kalpakkam during the period 1996-1997. The Fast Breeder Test Reactor (FBTR) was operated at the maximum power level possible with the available partial core. The first generation of electricity from FBTR and its synchronization with the grid in 1997 marked a significant step in the nuclear programme of the Centre. Another important event was the commissioning of the "2"3"3U - fuelled Kamini reactor.The mission-oriented programmes in fast reactor technology was supported by a host of research and development programmes, in closely related areas namely materials technology, welding metallurgy, sodium technology, manufacturing technology, non-destructive testing, quality engineering, in-service inspection, electronics and instrumentation and safety research. The Highlights also contains the organisation chart and the list of ...

138

Giant magnetoresistance sensing technologies for detecting small defects in metallic structures  

Science.gov (United States)

Giant magnetoresistance (GMR) has been used with Eddy current testing to detect small defects not only in thin film structures but also in multilayered metallic structures. This work detected small scratches in the thin film under the surface where these defects were unable to be inspected or monitored by regular testing. In addition, rotational GMR magnetic sensor based Eddy current probes were used for detecting buried corner cracks at the edge of holes in metallic structures. The results of this study proved that giant magnetoresistance is very powerful and effective to sense the magnetic field, which is the result from the perturbation of the Eddy currents caused by a defect. This method can be used for quality control of metallization layers on silicon wafer and to detect cracks in thick structures such as cracks in aging aircraft.

2008-01-01

139

Application of probabilistic safety assessment models to risk-based inspection of piping  

International Nuclear Information System (INIS)

From the beginning, one of the most useful applications of Probabilistic Safety Assessment (PSA) is its use in evaluating the risk importance of changes to plant design, operations, or other plant conditions. Risk importance measures the impact of a change on the risk. Risk is defined as a combination of the likelihood of failure and consequence of the failure. The consequence can be safety system unavailability, core melt frequency, early release, or various other consequence measures. The goal in this PSA application is to evaluate the risk importance of an ISI process, as applied to plant piping systems. Two approaches can be taken in this evaluation: Current PSA Approach or the Blended Approach. Both are discussed here.

1996-07-21

140

Quality assurance considerations in nuclear waste management  

International Nuclear Information System (INIS)

Proper use of quality assurance will provide the basis for an effective management control system for nuclear waste management programs. Control is essential for achieving successful programs free from costly losses and failures and for assuring the public and regulators that the environment and health and safety are being protected. The essence of quality assurance is the conscientious use of planned and systematic actions, based on selecting and applying appropriate requirements from an established quality assurance standard. Developing a quality assurance program consists of using knowledge of the technical and managerial aspects of a project to identify and evaluate risks of loss and failure and then to select appropriate quality assurance requirements that will minimize the risks. Those requirements are integrated into the project planning documents and are ...

141

A hybrid approach based on SERVQUAL and fuzzy TOPSIS for evaluating transportation service quality  

British Library Electronic Table of Contents (United Kingdom)

Managing service quality is vital to retain customer satisfaction and augment revenues for any business organization. Often it is difficult to assess service quality due to lack of quantifiable measures and limited data. In this paper, we present a hybrid approach based on SERVQUAL and fuzzy TOPSIS for evaluating service quality of urban transportation systems. The proposed approach consists of three steps. The first step involves development of a SERVQUAL based questionnaire to collect data for measuring transportation service quality. The participants provide linguistic assessments to rate the service quality criteria and the alternatives. In step 2, the linguistic ratings are combined through fuzzy TOPSIS to generate an overall performance score for each alternative. The alternative wit...

2011-01-01

142

Quality assurance program requirements (operation)  

International Nuclear Information System (INIS)

Apppendix B of 10 CFR Part 50 establishes quality assurance requirements for the operation of nuclear power plant safety-related structures, systems and components. This Guide describes an acceptable method for complying with these regulations with regard to overall quality assurance program requirements for the operation phase of nuclear power plants. Input to this Guide has been provided by the Advisory Committee on Reactor Safeguards.

143

Quality assurance program requirements (design and construction)  

International Nuclear Information System (INIS)

Appendix B to 10 CFR Part 50 establishes overall quality assurance requirements for the design, construction and operation of safety-related structures, systems, and components. This guide presents a method acceptable to the Commission for complying with these regulations with regard to overall quality assurance program requirements during design and construction of nuclear power plants. Input to this guide has been provided by the Advisory Committee on Reactor Safeguards.

144

Building ventilation, state of the art, prospective; Ventilation des batiments etat des lieux, prospective  

Energy Technology Data Exchange (ETDEWEB)

This conference is composed of 21 communications and 21 posters in the domain of building ventilation and indoor air quality; the main themes are: indoor air quality assessment and optimization; performance enhancement and optimization of ventilation systems and equipment; ventilation systems for renovated and rehabilitated buildings; French and European regulations, standardizations and certifications; experimental and numerical simulation studies concerning ventilation systems, air flow, temperature distribution, air quality, thermal comfort and ventilation-induced acoustic levels

1995-10-01

145

Maintaining Quality Performance in a Rapidly Changing Workplace - NASA  

Science.gov (United States)

360 degree Surveys. Measuring. Measuring successes successes ... Self- Assessment. Safeguards. Equipment. Reactor. Protection. Systems. Containment ...

146

Enhanced Reliability MEMS Deformable Mirrors for Space Imaging ...  

Science.gov (United States)

Sep 3, 2010 ... These higher-quality deformable mirrors will enable diffraction-limited performance for many space-based optical systems such as space-based ...

147

Ashbrook Simon-Hartley Profile on Environmental Expert  

Wastenet

...been a world leader in the design, manufacture and installation of high quality precision-engineered systems for water and wastewater treatment fo Create Free Account ...

148

Ashbrook Simon-Hartley Profile on Environmental Expert  

Wastenet

...been a world leader in the design, manufacture and installation of high quality precision-engineered systems for water and wastewater treatment fo Bulletins Environmental Expert ...

149

A Danish decision-support GIS tool for management of urban air quality and human exposures  

Energy Technology Data Exchange (ETDEWEB)

A new prototype model system named AirGIS has been developed to support local authorities in air quality management for big Danish cities. The system is based on the Danish operational street pollution model (OSPM), technical and cadastral digital maps and Danish national administrative databases on buildings, cadastres and populations. It applies a geographic information system (GIS). AirGIS estimates ambient air pollution levels at high temporal and spatial resolutions. The model system enables mapping of traffic emissions, air quality levels and human exposures at residence addresses, at workplace addresses and in streets. Mapping and scenario results can be compared with air quality limits. Impact assessment of traffic air pollution abatement measures can also be carried out. (author)

2001-07-01

150

Real-time 3-D SAFT-UT system evaluation and validation  

International Nuclear Information System (INIS)

SAFT-UT technology is shown to provide significant enhancements to the inspection of materials used in US nuclear power plants. This report provides guidelines for the implementation of SAFT-UT technology and shows the results from its application. An overview of the development of SAFT-UT is provided so that the reader may become familiar with the technology. Then the basic fundamentals are presented with an extensive list of references. A comprehensive operating procedure, which is used in conjunction with the SAFT-UT field system developed by Pacific Northwest Laboratory (PNL), provides the recipe for both SAFT data acquisition and analysis. The specification for the hardware implementation is provided for the SAFT-UT system along with a description of the subsequent developments and improvements. One development of technical interest is the SAFT real time processor. Performance of the real-time processor is impressive ...

1993-05-17

151

Operational experiences with cathodic protection of Statoil's main onshore pipelines: a description of the online monitoring systems  

Energy Technology Data Exchange (ETDEWEB)

Statoil is operating an increasing number of offshore and onshore pipelines in the North Sea area and elsewhere. Cathodic protection is a significant part of the corrosion management for these lines and we have collected a significant amount of experience with respect to design and operation of the systems. This paper deals with our comprehensive program for the onshore cathodic protection systems and the various challenges in different countries with respect to technical matters, such as operating conditions and different terrain. Generally, the systems are based on automatically controlled rectifier systems with a wide range of current drainage and very comprehensive monitoring of potentials and current flowing. The use of coupons, polarisation cells and buried reference cells are essential, as well as the use of intensive measurements along the route. The use of online monitoring of selected test ...

1999-07-01

152

Technical requirements for the ASME PRA standard for nuclear power plant applications  

Energy Technology Data Exchange (ETDEWEB)

In 1998 the American Society of Mechanical Engineers (ASME) formed the Committee on Nuclear Risk Management (CNRM) and a Project Team to develop a standard on PRAs for use in risk informed applications. This ASME standard is being developed to help provide an adequate level of quality in PRAs that are being used to support ASME initiatives to risk informed in-service inspection (ISI) and in-service testing (IST) of nuclear power plant components. A related need supported by the industry and the U.S. Nuclear Regulatory Commission is to reduce the level of effort that is being expended in pilot applications of risk informed initiatives to address questions about the sufficiency of quality in the supporting PRA models. The purpose of this paper is to discuss the authors' views on some of the technical issues that were encountered in the effort to develop the ASME PRA standard. Draft 12 of this standard has been issued ...

2000-07-01

153

Technical requirements for the ASME PRA standard for nuclear power plant applications  

International Nuclear Information System (INIS)

In 1998 the American Society of Mechanical Engineers (ASME) formed the Committee on Nuclear Risk Management (CNRM) and a Project Team to develop a standard on PRAs for use in risk informed applications. This ASME standard is being developed to help provide an adequate level of quality in PRAs that are being used to support ASME initiatives to risk informed in-service inspection (ISI) and in-service testing (IST) of nuclear power plant components. A related need supported by the industry and the U.S. Nuclear Regulatory Commission is to reduce the level of effort that is being expended in pilot applications of risk informed initiatives to address questions about the sufficiency of quality in the supporting PRA models. The purpose of this paper is to discuss the authors' views on some of the technical issues that were encountered in the effort to develop the ASME PRA standard. Draft 12 of this standard has been issued for ...

154

Development of PHWR fuel fabrication in Korea  

Energy Technology Data Exchange (ETDEWEB)

Korea Advanced Energy Research Institute (KAERI) started a research project to develop the PHWR (CANDU) nuclear fuel fabrication technology in 1981. Based on the results of the intensive developmental work, several prototype fuel bundles were fabricated and tested in the Hot Test Loop at KAERI continuously in 1983 and 1984. After that, irradiation test and post-irradiation examination were carried out for two KAERI-made fuel bundles at Chalk River Nuclear Laboratories in Canada in 1984. Since the results of in-pile and out-of-pile tests with prototype fuel bundles proved to be satisfactory, 48 additional fuel bundles were loaded in Wolsung reactor (CANDU) in 1984 and 1985, and all of them were discharged without a defect after excellent performance in the power reactor. In 1985, the Korean government decided that KAERI supplies all the fuel necessary for the Wolsung reactor. For the mass production of nuclear fuel bundle, several process equipment, facilities and automation methods ...

1988-01-01

155

A smart location system  

Energy Technology Data Exchange (ETDEWEB)

Details of a novel intelligent pipeline anomaly location system were presented. The system was based on the emission and reception of extra low frequencies(ELF) disposed close to a pipeline that were then logged in the memory of an in-line inspection (ILI) tool to provide a more precise reference than time-based above-ground marker systems for the location of pipeline anomalies. The system consisted of 2 pairs of transmitter (TX) and receiving (RX) circuits working at low and varied frequencies. An additional module was installed in the front section of an ILI tool, which contained a frequency transmitter whose signals are transmitted through cabling to an external transmitter and retransmitted simultaneously to a receiver installed in the rear section of an additional module of the tool in order to guarantee that the signal recorded by the tool corresponded to the smart location ...

2004-07-01

156

Regulatory quality assurance requirements for the operation of nuclear R and D facilities in Korea  

International Nuclear Information System (INIS)

Full text: Korea Atomic Energy Research Institute (KAERI) has many R and D facilities in operation. including HANARO research reactor, radioactive waste treatment facility (RWTF), post-irradiation examination facility (PIEF) and irradiated material test facility (IMEF). Recently. nation-wide interest is focused on the safety and security of major industrial facilities. Safe operation of nuclear facilities is imperative because of the consequence of public disaster by radiological release/contamination, in case of an accident. Recently, Ministry of Science and Technology (MOST) of the Korean government announced amendments of Atomic Energy laws to enforce requirements of the physical protection and radiological emergency. All provisions on nuclear safety regulation and radiation protection are entrusted to the Atomic Energy Act(AEA). The Act is enacted as the main law concerning the safety regulation of nuclear installations, and is supplemented by the Enforcement Decree and Enforcement ...

2006-10-15

157

The application of expert systems technology to rotating machine condition monitoring  

Energy Technology Data Exchange (ETDEWEB)

An expert system was developed which helps maintenance personnel diagnose the condition of rotor and stator windings and their cores, in motors and generators rated 2300 V and above. The expert system, called MICAA[TM], used an approach which has been found to be effective for diagnosing medical problems. The program required the user to input machine nameplate information, operating status, and any past test data available. In addition, the program would suggest tests that may be useful, as well as provide guidance to maintenance personnel on what to look for in visual inspections of the machine. The expert system stored and correlated all this information, calculated the overall condition of the component in question, and identified the most likely specific causes of any deterioration. The basic methodology of motor and generator condition assessment, and the architecture and processing performed by ...

1995-12-31

158

Implantation of an electronic system for real time neutron graphic images acquisition at the IPEN/CNEN Argonaut reactor; Implantacao de um sistema eletronico para aquisicao de imagens neutrongraficas em tempo real no reator Argonauta do IEN/CNEN  

Energy Technology Data Exchange (ETDEWEB)

The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)

2004-04-15

159

Electronic imaging system for neutron radiography at a low power research reactor  

Energy Technology Data Exchange (ETDEWEB)

This paper describes an electronic imaging system for producing real time neutron radiography from a low power research reactor, which will allow inspections of samples with high efficiency, in terms of measuring time and result analysis. This system has been implanted because of its potential use in various scientific and industrial areas where neutron radiography with photographic film could not be applied. This real time system is installed in neutron radiography facility of Argonauta nuclear research reactor, at the Instituto de Engenharia Nuclear of the Comissao Nacional de Energia Nuclear, in Brazil. It is adequate to perform real time neutron radiography of static and dynamic events of samples.

2010-08-15

160

Electronic imaging system for neutron radiography at a low power research reactor  

International Nuclear Information System (INIS)

This paper describes an electronic imaging system for producing real time neutron radiography from a low power research reactor, which will allow inspections of samples with high efficiency, in terms of measuring time and result analysis. This system has been implanted because of its potential use in various scientific and industrial areas where neutron radiography with photographic film could not be applied. This real time system is installed in neutron radiography facility of Argonauta nuclear research reactor, at the Instituto de Engenharia Nuclear of the Comissao Nacional de Energia Nuclear, in Brazil. It is adequate to perform real time neutron radiography of static and dynamic events of samples.

2010-08-01

161

A Review of the IAEA Vulnerability Assessment Level Scheme: Applicabiliy to DTRA and DOE Programs in the FSU  

Energy Technology Data Exchange (ETDEWEB)

The International Atomic Energy Agency (IAEA) plans to use the Common Criteria, as the tool for developing graded and measurable evaluation criteria for information technology (IT) in safeguards systems in facilities subject to IAEA inspection. In their draft paper [ITSECSES] the IAEA defines a three-tiered Vulnerability Assessment Level (VAL) scheme. Each increased VAL level (1-3) defines additional and more stringent security and security-related requirements for the system developer, the system evaluator (assessor or authenticator), and for the IAEA. When all parties meet all requirements for a particular VAL level, IAEA has a measurable degree of confidence in the secure and proper operation of an IT system.

2001-12-06

162

Development of quality assurance requirements - an international comparison  

International Nuclear Information System (INIS)

Total quality management strategy and the worldwide introduction of the DIN/ISO 9000 (EN 29 000) series of standards have given new impetus to traditional quality assurance. The most important change must surely be seen in the holistic approach of total quality management and its strict orientation towards customer requirements and satisfaction. International codes and standards for the nuclear industry will also have to be brought into line as part of the process of harmonizing quality assurance system standards. One possible approach is simply to specify a supplementary 'delta' of nuclear-specific requirements to be appended to the broad range of conventional requirements. It is a particular feature of quality-assured procedures in Germany that product and/or component related quality requirements and quality ...

163

Hybrid ventilation. Control strategies for hybrid ventilation, consequences for air quality, thermal comfort and energy use; Hybrid ventilasjon  

Energy Technology Data Exchange (ETDEWEB)

This article deals with the need for control strategies and control systems in buildings with hybrid ventilation. In this respect, control strategies are methods of keeping certain parameters like temperature, air quality etc within specified limits. A control system is automatic and includes sensors, motors, dampers etc. The article also discusses consequences with respect to thermal comfort, air quality and energy use following selection of control parameters for controlling air masses.

2001-07-01

164

Environmental Restoration Program quality assurance system requirements for the Hanford Site  

International Nuclear Information System (INIS)

This document defines the quality assurance program requirements for the US Department of Energy, Richland Field Office, Environmental Restoration program at the Hanford Site. This document integrates quality assurance requirements from US Department of Energy Orders, the Hanford Federal Facility Agreement and Consent Order, and applicable industry standards into a single source document for the development of quality assurance programs applicable to the Environmental Restoration program items and activities. This document has been configured into three parts and fifteen criteria to provide user organizations with a workable document that best facilitates line operations. When developing individual user organization quality assurance programs, the document configuration provides each organization with the Flexibility to incorporate only those parts and criteria that are applicable to their individual ...

165

Combined heuristic with fuzzy system to transmission system expansion planning  

Energy Technology Data Exchange (ETDEWEB)

A heuristic algorithm that employs fuzzy logic is proposed to the power system transmission expansion planning problem. The algorithm is based on the divide to conquer strategy, which is controlled by the fuzzy system. The algorithm provides high quality solutions with the use of fuzzy decision making, which is based on nondeterministic criteria to guide the search. The fuzzy system provides a self-adjusting mechanism that eliminates the manual adjustment of parameters to each system being solved. (author)

2011-01-15

166

Automated Eddy Current Inspection of Space Shuttle APV ...  

Science.gov (United States)

... perform the inspection in the extremely limited space between adjacent blades and at the blade root, miniature eddy current probes were developed ...

167

Recommendations and quality control in brachytherapy; Recommandations pour le controle de qualite en curietherapie  

Energy Technology Data Exchange (ETDEWEB)

Brachytherapy consists of sealed radioactive source implantation. The diversity in the nature of radioelements, in their energy and activity requires strict implantation and utilization rules. These rules include radioactive source physical parameters check, after-loading machine and treatment planning system quality assurance and safe and reproducible dosimetric systems. Patient and medical workers information guarantee radioprotection and prevention of accidental exposures. (authors)

2002-11-01

168

Evaluation of chips quality by the analysis of two different harvesting methodologies  

Energy Technology Data Exchange (ETDEWEB)

The Council for Research in Agriculture, Agricultural Engineering Research Unit (CRA-ING) in Rome, Italy has developed an innovative short-rotation forestry (SRF) harvesting system. The system involves a 2 step operation, notably the tree felling and inter-row windrowing performed by a feller windrower equipment; and subsequent chipping performed by a harvester equipped with a pick-up device. The low moisture content of the windrowed trees at harvesting time affects their physical qualities and mechanical strength throughout the chipping operation. The purpose of this study was to analyze the moisture losses of windrowed trees, in relation to the windrow location, on field storage and weather condition. In addition, the study characterized chips quality changes during on field storage by the 2 different harvesting systems. The innovative 2-step system was ...

2010-07-01

169

Digital processing to improve image quality in real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction technique, and so on. For the real-time application a contouring operation and an averaging approach can also be utilized effectively.

1985-01-01

170

Digital processing to improve image quality in real-time neutron radiography  

International Nuclear Information System (INIS)

Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction technique, and so on. For the real-time application a contouring operation and an averaging approach can also be utilized effectively. ...

1985-01-01

171

Coal quality engineering aids purchasing  

Energy Technology Data Exchange (ETDEWEB)

New York State Electric and Gas Co. (NYSEG) has developed a tool called Coal Quality Engineering Analysis (CQEA) to evaluate the cost impacts of coal quality on its power plants. CQEA allows quantification of the effect of coal quality on plant operating costs and has become an important factor in coal purchasing. The article describes the development of the analysis method, including a logic diagram of CQEA relationships. The results of CQEA calculations on the impact of one coal on overall production costs of different units, the impact of different coals on overall production costs of one unit, and production cost vs. coal quality, are presented and discussed. The use of the CQEA system within NYSEG is described.

1987-06-01

172

Technical support of regulatory authority in Ukraine  

International Nuclear Information System (INIS)

Main results of 15-year SSTC NRS activity in the field of technical support of regulatory authority are presented. The article also described management policy, quality assurance system, personnel training system and international co-operation of SSTC. (author)

2007-08-01

173

Ravenscraig coke ovens 1988 and onwards  

Energy Technology Data Exchange (ETDEWEB)

The coking plant is described with some details of coal supplies and coke quality. Engineering improvements to the by-product system and coke oven machines, major repair of two batteries, installation of a PLC-based monitoring and control system, and training of personnel are dealt with at greater length.

1989-01-01

174

Gastrointestinal radiography using Fuji computed radiography (FCR)  

International Nuclear Information System (INIS)

Initial clinical experience in gastrointestinal radiography using Fuji Computed Radiography(FCR) system was reported. Image quality of conventional film/screen radiography and FCR system on upper GI series and barium enema was compared. Reflecting wide dynamic range of the system, improved image quality was confirmed, particularity in visibility of fine mucosal pattern(area gastricae), folds and overall contour. High sensor sensitivity of the system could reduce radiation dose requirement significantly. Diagnostically acceptable images were obtained with approximately 1/5 of routine dose for conventional radiography except in cases of lateral view of the rectum. (author).

1985-01-01

175

Failure modes, reliability and integrity of floating storage unit (FPSO, FSU) turret and swivel systems  

Energy Technology Data Exchange (ETDEWEB)

This report provides an assessment of the designs of turret and swivel systems for floating production, storage and offloading (FPSO) vessels and floating storage Units (FSU) which are either purpose built or converted from tankers. Use of FPSO and FSO in the North Sea with the move to subsea and deepwater production is discussed, and the background to FPSO and FSU turret systems is traced. Details are given of general issues relating to ship structure, systems affecting the turret, swivel systems, mooring systems, turret loading, scaffolding and support structure, on-board personnel, and construction standards. Turret system components and types are described, and failure modes, operation and safety relevant components are examined. Inspection and maintenance, examples of good and poor practice, and applicable regulations are considered. ...

2002-07-01

176

A study on the transient piping vibration of power plant. Secondary piping system of Wolsung 1 unit  

Energy Technology Data Exchange (ETDEWEB)

In order to maintain a safe operation and availability of generating facilities, qualitative and quantitative assessment of piping vibration was performed vibration sources and damages of piping support was identified on the second piping system of Wolsung nuclear power plant unit 1 .Inspected piping supports and structures in both hot and cold condition .Established evaluation procedures of piping vibration .Performed the static analysis of 2 nd piping system .Established optimal vibration reducing method .The measured vibration level after installing rigid supports and energy absorbing type restraint was reduced about 7 times in velocity unit (author). 24 refs., 95 figs.

1996-08-01

177

Wall thinning trend analyses for secondary side piping of Korean NPPs  

International Nuclear Information System (INIS)

Since the mid-1990s, nuclear power plants in Korea have experienced wall thinning, leaks, and ruptures of secondary side piping caused by flow-accelerated corrosion (FAC). The pipe failures have increased as operating time progresses. In order to prevent the FAC-induced pipe failures and to develop an effective FAC management strategy, KEPRI and KOPEC have conducted a study for developing systematic FAC management technology for secondary side piping of all Korean nuclear power plants. As a part of the study, FAC analyses were performed using the CHECWORKS code. The analysis results were used to select components for inspection and to determine inspection intervals on each nuclear power plant. This paper describes the introduction of the FAC analysis method and the wall thinning trend analysis results by reactor type, system, and water treatment amine. This paper also represents the site application feasibility for ...

2003-08-17

178

Inspection of PFR steam generators  

International Nuclear Information System (INIS)

The inspection of PFR evaporator tubing, superheater and reheater tubing, and tube plate examinations, are described. Ferritic steel U tubes in the evaporator have been examined by an eddy current system operating at 400 kHz using flexible rotating probes. Surface defects as shallow as 0.1 mm can be detected and sized in the range 0.1 to 0.5 mm deep. An ultrasonic method is under development for wall thickness. Special test coil probes have been developed for examination of the type 316 stainless steel superheater and reheater tubing. Crack-life defects in the bore are detectable at approximately 10% wall thickness and 20% on the outside diameter. Tube plate examinations from the tube holes, have been conducted using eddy current probes which identify surface breaking cracks in the holes. For detecting curtain cracks between tube plate holes, ultrasonic compression wave probes have been used. (U.K.).

1976-03-09

179

Cost reduced inspection concept of PE/XLPE medium voltage cables; Kostensparende Zustandsanalyse an PE-/VPE-isolierten Mittelspannungskabeln  

Energy Technology Data Exchange (ETDEWEB)

The microelectronic cable diagnosis is a substantial tool to determine destruction free the residual strength and the lifetime of laid PE/XLPE medium voltage cables. Fundamentals of the ageing diagnosis and a cost reduced inspection concept are the `Isothermal-Relaxation-Current` Analysis and the Neuro-Fuzzy evaluation software. These new tools are able to determine the ageing status of the investigated cable without any references. The authors also show that the test breakdown during the assessment of the ageing status of criterial systems can be reduced by this approach. The cable diagnosis equipment KDA is also useful for the steering of investment as well as for preventive maintenance. (orig.) [Deutsch] Die zerstoerungsfreie dielektrische Kabeldiagnostik kann heute einen wesentlichen Beitrag zur Bestimmung der Restfestigkeit und der Restlebensdauer eines PE/VPE-isolierten Mittelspannungskabels leisten. Basis der Alterungsdiagnose und des ...

1997-12-15

180

Current ventilation and air conditioning systems and strategies  

Energy Technology Data Exchange (ETDEWEB)

The report examines common ventilation and air conditioning systems and strategies for both domestic and commercial buildings; and covers issues such as energy conservation, indoor air quality and occupant comfort. Drawing data from many countries in Europe and the United States of America, various natural, mechanical and air conditioning systems were compared using criteria such as climate, level of occupant interaction, and level of system comfort. This classification system is evaluated and seen as a valuable framework for further research. (U.K.)

1994-02-01

181

Environmental Restoration Project quality system requirements for the Hanford Site. Revision 3  

International Nuclear Information System (INIS)

This document defines the quality system requirements for the US Department of Energy, Richland Operations Office (DOE-RL), Environmental Restoration (ER) Project at the Hanford Site. The Environmental Restoration Project Quality System Requirements for the Hanford Site integrates quality assurance requirements from the DOE Orders, the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement), the Hanford Facility Resource Conservation and Recovery Act of 1976 (RCRA) Permit, and applicable Federal and Washington State regulations. This document, based on ten criteria, provides user organizations with the flexibility to incorporate only those criteria and paragraphs applicable to their specific scopes of work. The requirements of this document are to be applied based on a graded approach that takes into consideration the risk inherent in, as well as the importance ...

182

Comparison of the quality of the chest film between digital radiography and conventional high kV radiography  

International Nuclear Information System (INIS)

Objective: To evaluate the quality and usefulness of direct digital radiography system in roentgenogram of chest in clinical practice. Methods: 1000 cases of chest roentgenograms with digital radiography and high kV conventional radiography were selected for analysis by 3 senior radiologists. Results: 1. With digital radiography system, the quality of chest film was assessed as grade A in 50.6%, grade B in 38.5%, grade C in 10.9%, and no waste film. 2. With conventional high kV radiography, the quality of chest film was assessed as grade A in 41.1%, grade B in 44.1%, grade C in 13.3%, and waste film in 1.5%. The direct digital radiography was statistically superior to the conventional high kV radiography. 3. The fine structure of the lungs could be revealed in 100.0% of chest roentgenogram with direct digital radiograph system, which was significantly higher ...

2003-02-01

183

Quality assurance requirements and description for the Civilian Radioactive Waste Management Program  

International Nuclear Information System (INIS)

The Quality Assurance Requirements and Description (QARD) is the principal quality assurance document for the Civilian Radioactive Waste Management Program (Program). It establishes the minimum requirements for the Quality Assurance Program. The QARD contains regulatory requirements and program commitments necessary for the development of an effective quality assurance program. Quality assurance implementing documents must be based on, and consistent with, QARD requirements. The QARD applies to the following: (1) acceptance of spent nuclear fuel and high-level radioactive waste; (2) transport of spent nuclear fuel and high-level radioactive waste; (3) the Monitored Retrievable Storage (MRS) facility through application for an operating license; (4) Mined Geologic Disposal System (MGDS), including the site characterization activities (exploratory studies facility ...

184

Non-destructive Inspection of Surfaces  

International Science & Technology Center (ISTC)

Highly Precision Method for Nondestructive Analysis of Surfaces in a Subnanometer Depth Range

185

INFLATABLE EDDY CURRENT INSPECTION PROBE FOR ...  

Science.gov (United States)

... INTERMEDIATE TO THE CENTRALIZERS IS A SENSING SECTION COMPRISED OF MULTIPLE EDDY CURRENT PROBES ON FLEXIBLE ...

1981-12-01

186

Studies of the correlated electron system SmB_6  

International Nuclear Information System (INIS)

We have prepared high-quality, single crystals of SmB_6 under various conditions to improve sample quality. We have measured the resistivity and magnetic susceptibility from room to liquid-helium temperatures to sort samples. We have applied pulsed magnetic fields as high as 50 T at temperatures as low as 40 mK while measuring resistivity. Our samples are of higher quality than previously known. All solvent-grown, single-crystal samples should be etched to remove a surface conductivity. (orig.).

187

Radiological protection. Textbook for radiographers and reference book for radiological safety officers  

International Nuclear Information System (INIS)

The textbook is primarily intended for radiologic staff and radiologic safety officers and gives information on the current regulatory provisions of the German X-ray Ordinance, applications of X-rays, quality assurance, organisational aspects of film processing and quality requirements of X-rays. An annex lists the guidelines of the Bundesaerztekammer (German National Chamber of Physicians) relating to quality assurance aspects, and further useful information on commercially available film-screen systems, the various associations of physicians in Germany, and requirements and performance of radiation surveys. (vhe).

188

Key methods for sustaining quality engineering data in nuclear power plants  

International Nuclear Information System (INIS)

This paper discusses key methods for sustaining quality engineering data, the fundamental principles that these methods are based on, and the methods for supporting the performance of nuclear power plants by the provision of quality engineering data at all times. The concept of an 'engineering data foundation', and a Configuration Management data model are developed. The concepts and methods for managing the integrity of engineering data across many different databases and document systems are developed, including the key concepts of data-positions and data-values, Master Data and Copy Data, and the concept of a 'partnership between people and technology'. (author). 7 refs., 1 tab., 2 figs.

1995-06-04

189

Improving air quality in tertiary buildings; Ameliorer la qualite de l'air dans les batiments tertiaires  

Energy Technology Data Exchange (ETDEWEB)

In order to promote the use of natural gas air-conditioning systems in the tertiary sector, Gaz de France (the French gas utility) in association with Electricite de France (EdF) and the French chamber of council engineers (CICF) have created the Acerclim organization which aims at certifying the quality of the design, realization and exploitation of air processing and air-conditioning installations according to the ISO 9001 criteria. This article describes this quality procedure named 'CHSB Air'. (J.S.)

2002-07-01

190

Nuclear material accountability by isotope dilution mass spectrometry  

International Nuclear Information System (INIS)

This paper discusses the mass spectrometric system that has been developed at the ICPP (Idaho Chemical Processing Plant) to meet the multiple constraints of U accountability, high sample load, and plant process control. The measurement system must produce high-quality accountability results while maintaining high sample throughput and reasonable turnaround time. The mass spectrometric system that has evolved to meet these demands includes extensive operator training, routine quality control checks, and continuing review of performance. 7 refs.

1981-07-13

191

Safety gas management system utilizing telephone cable  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the safety gas management system utilizing public telephone cables. Buyo Gas Co., Ltd. has installed about 100 governors for exclusive-use or use in the districts to control the gas supply to the consumers. A gas safety management system has been developed. This system consists of a pressure sensor, the terminals of gas leak alarms, and their masters. The features lie in that the system can utilize public cables, is operative at interruption of power service, can correspond to emergency situations, serves to save the cost, and can display the data constantly. For electric facilities in a governor room and the NTT cable service work, sufficient agreement with the possessor is required. In the case of non-utility electric facilities, some restrictions are imposed on the cable work for laying from privately-owned transformers, etc. Insurance for the facilities is necessary to prepare ...

1988-02-10

192

Idaho National Laboratory Supervisory Control and Data Acquisition Intrusion Detection System (SCADA IDS)  

Energy Technology Data Exchange (ETDEWEB)

Current Intrusion Detection System (IDS) technology is not suited to be widely deployed inside a Supervisory, Control and Data Acquisition (SCADA) environment. Anomaly- and signature-based IDS technologies have developed methods to cover information technology-based networks activity and protocols effectively. However, these IDS technologies do not include the fine protocol granularity required to ensure network security inside an environment with weak protocols lacking authentication and encryption. By implementing a more specific and more intelligent packet inspection mechanism, tailored traffic flow analysis, and unique packet tampering detection, IDS technology developed specifically for SCADA environments can be deployed with confidence in detecting malicious activity.

2008-05-01

193

Eddy currents signal processing for steam generator inspection in PWR nuclear power plants  

International Nuclear Information System (INIS)

Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostic system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of these items.

1992-01-01

194

Development and application of gamma scanning technology for on-line investigation of industrial process columns and vessels  

International Nuclear Information System (INIS)

Plant Assessment Technology (PAT) group, in association with Intelligent System (IS) Group and Engineering Services Department of Malaysian Institute for Nuclear Technology Research (MINT) has developed gamma scanning facilities for on-line investigation of industrial process columns and vessels. The technology, based on the principle of gamma-ray absorption, has been successfully applied for troubleshooting of a number of distillation columns and process vessels in petroleum refineries, gas processing plants and chemical plants in the country and the region. This paper outlines basic characteristics of the system and describes the inspection procedures, and in addition, case studies are also presented. The case studies are purposely chosen to illustrate the versatility of the technology, and furthermore to demonstrate the economic benefits which can be realised from the application of this technology. (author)

1998-10-30

195

A note on classical ground state energies  

CERN Document Server

The pair-specific ground state energy of Newtonian N-body systems grows monotonically in N. This furnishes a whole family of simple new tests for minimality of putative ground state energies obtained through computer experiments. Inspection of several publically available lists of such computer-experimentally obtained putative ground state energies has yielded several dozen instances which failed (at least) one of these tests. Although the correct ground state energy is not revealed by this method, it does yield a better upper bound on it than the experimentally found value whenever the latter fails a monotonicity test. The surveyed N-body systems include in particular N point charges with 2- or 3-dimensional Coulomb pair interactions, placed either on the unit 2-sphere or on a 2-torus (a.k.a. Thomson, Fekete, or Riesz problems).

2009-01-01

196

Results of the 2nd periodical inspection of the asphalt solidification facility and the incinerator in Unit 2 of the Sendai Nuclear Power Station  

International Nuclear Information System (INIS)

The 2nd periodical inspection was carried out on the asphalt solidification facility and the incinerator in Unit 2 of the Sendai Nuclear Power Station from November 5 to 28, 1985. Inspection was made in radiation control facility and disposal facility. By external appearance, disassembly, function and performance tests there were observed no abnormalities. The personnel exposure doses during the inspection were below the permissible level. In the inspection, improvement etc. works were not done. (Mori, K.).

1986-01-01

197

Terra Nova 2006 turnaround  

Energy Technology Data Exchange (ETDEWEB)

Petro-Canada's Terra Nova offshore oil platform was designed with the expectation that its Floating, Production, Storage and Offloading (FPSO) vessel would be taken off location for maintenance and modifications work within the first 10 years of operation. Petro-Canada's 2006 extended Turnaround project was initiated to prepare for the maintenance and transport of the FPSO. The project aimed to execute an extended turnaround in approximately 90 days. The cost of the project was estimated at $190.5 million. Shutdown occurred early on May 7, 2006 due to the failure of a generator gearbox. Staff were increased from 80 to 120 to complete critical preparation work. On June 17, the FPSO was disconnected and departed for Conception Bay. A turret cover plate was installed, and the FPSO began its voyage to a Rotterdam shipyard in the Netherlands. In order to complete the journey, a comprehensive marine transit manual and emergency response plan was needed. The vessel transited ...

2006-07-01

198

IEA Annex 27. Assessment of air quality, comfort and sound of ventilation systems in houses; IEA Annex 27. Beoordeling van woningventilatiesystemen op luchtkwaliteit, comfort en geluid  

Energy Technology Data Exchange (ETDEWEB)

In the international study of IEA Annex 27 `Demonstration and evaluation of domestic ventilation systems` a number of simple tools to gain insight into the characteristics of ventilation systems for dwellings are presented. The assessment is made with respect to e.g. indoor air quality, comfort, noise, energy, costs and reliability. In three articles the results of Annex 27 will be discussed. In the first article background information of IEA Annex 27 was given as well as applications in the Netherlands. In this second article attention is paid to the assessment models (`simplified tools`) for indoor air quality, thermal comfort and noise. 6 refs.

1999-09-01

199

Radiation doses in adults and children in standardized diagnostic radiology  

International Nuclear Information System (INIS)

For comparison of radiation exposure and risk in different diagnostic procedures for adults and children dose measurements and calculations of organs with special risk were carried out. Parameters of image formation influencing image quality as well as of exposure concerning infants and children are recorded and discussed as to radiation exposure and protection. Conclusions are drawn with respect to systems of image formation and to standards of examination and quality assurance.

1987-01-01

200

Quality assurance requirements for the design of nuclear fuel reprocessing facilities  

International Nuclear Information System (INIS)

Requirements and guidance are provided for a quality assurance program for the design of nuclear fuel reprocessing facilities involving structures, systems and components whose satisfactory performance is required to prevent accidents that could cause undue risk to the health and safety of the public, or to mitigate the consequences of such accidents if they were to occur. The standard is to be used in conjunction with ANSI N46.2.

201

BBSRC CASE studentship: The impact of nutrition on the gluten composition and processing quality of wheat  

Environmental Research Database

DescriptionThe objective of this project is to relate the processing quality of wheat to the composition of the developing and mature grain using material grown under a range of nutrient regimes including long term organic and fertilised systems from the Rothamsted Broadbalk experiment, variety trials and organically grown wheat. Preliminary studies have indicated substantial differences in the transcriptome profiles of wheat grown with artificial fertiliser and with organic fertiliser on Broadbalk and tru [continued...

2008-01-31

202

Atlas of room air flow; Raumstroemungsatlas  

Energy Technology Data Exchange (ETDEWEB)

Within the framework of the IEA project Annex 20 - Airflow patters within buildings , an airflow data base was built up as a prototype. It enables airflow profiles, comfort and interior air quality to be studied without having to carry out a 1:1 experiment or having to run an expensive simulation code. The data base contains a number of pre-calculated room airflow profiles with their associated depictions of air quality and risks of drafts for given premises and for different ventilation systems. figs., tabs., refs.

1994-12-31

203

An intelligent management system for corporate information- calculating network development  

CERN Document Server

An approach to solving the problem of managerial control quality improvement corporate information-calculating networks (CICN) is proposed. The approach is based on the concept of a flexible toolkit. A macro-model, system-science and system-engineering models of an intelligent managerial control system (IMCS) for CICN development are considered as well as its dynamics. The practical opportunity of IMCS implementation is assessed. (5 refs).

2001-01-01

204

NAS battery demonstration at American Electric Power:a study for the DOE energy storage program.  

Energy Technology Data Exchange (ETDEWEB)

The first U.S. demonstration of the NGK sodium/sulfur battery technology was launched in August 2002 when a prototype system was installed at a commercial office building in Gahanna, Ohio. American Electric Power served as the host utility that provided the office space and technical support throughout the project. The system was used to both reduce demand peaks (peak-shaving operation) and to mitigate grid power disturbances (power quality operation) at the demonstration site. This report documents the results of the demonstration, provides an economic analysis of a commercial sodium/sulfur battery energy storage system at a typical site, and describes a side-by-side demonstration of the capabilities of the sodium/sulfur battery system, a lead-acid battery system, and a flywheel-based energy storage system in a power ...

2006-03-01

205

Quality differentiated tariffs; Kvalitetdifferensierte tariffer  

Energy Technology Data Exchange (ETDEWEB)

Flexible delivery reliability (FLP), which is in focus in this report, means that the customer shall be able to choose from a number of different grid tariffs of different qualities. This way he shows his actual willingness to pay for quality. It is an important difference compared with the KILE system, which is based on a surveyed willingness to pay. As it is planned to be implemented, FLP assumes that the customer must choose one of a number of different subscriptions and that he makes his choice based on his own preferences and costs what suits him best. The various subscribers entail different degrees of delivery reliability. For the grid companies, customers and regulatory authorities the FLP represents a challenge. It is assumed that the customers have a conscious attitude or preference with respect to delivery quality. That is not always the case today.

2003-11-01

206

Decree of the Czechoslovak Atomic Energy Commission No. 436/1990 on quality assurance of selected facilities with respect to nuclear safety of nuclear facilities  

International Nuclear Information System (INIS)

The Decree specifies basic quality assurance requirements applicable to machines, their parts and materials, civil engineering structures, means for automated control of technological processes including hardware and software, and electricity supply systems related to nuclear safety of nuclear facilities, and stipulates binding procedures for the implementation of technical and organizational provisions associated with the quality of selected equipment to ensure nuclear safety of nuclear facilities. Safety classes are defined for selected equipment. Requirements laid on safety assurance documentation are specified, and requirements placed on safety assurance programmes, their preparation, finalization and approval are defined. Quality assurance requirements are also specified with respect to the designing, manufacture, construction, operation, repair, modification and decommissioning of nuclear ...

1995-02-01

207

Base flow hydrology and water quality of an Ozarks spring and associated recharge area, southern Missouri, USA  

British Library Electronic Table of Contents (United Kingdom)

Human activities in the karst Ozark Plateaus can impact water quality of springs where surface water is rapidly transferred to subsurface conduits. Bennett Spring, in southern Missouri, is the fourth largest spring in the state and supports local tourism activities. Questions regarding poorly functioning on-site wastewater systems (OWS) have raised concerns over the long-term water quality of the spring. This study reports the results of a surface water quality monitoring program in the recharge area where monthly samples were collected at base flow to identify potential pollution sources to the spring. Base flow hydrology of the recharge area was highly variable over the study period, which was drier than normal, causing an incomplete sampling record due to no flow conditions at some site...

2011-01-01

208

The Power Industry Reform and the lesson from California Situation  

Energy Technology Data Exchange (ETDEWEB)

What kind of lesson do we get from California situation? The first is that the sufficient investment to the operational regulation should be prepared as a system. It is necessary to introduce the systems related to capacity, such as the capacity market system that makes retail suppliers secure the fixed rate of their running peak-load as reserve capacity and other system that secure the 5-year supply capacity by a contract, in which suppliers can pay the penalty if they purchase more capacity than in the contract. The second is that the supplementary measures should be systematized for the supply system not to be in a panic in a case of the shortage situation of equipment. The exchange authority should control the regular inspection program on generators to reduce the market control of the supply companies. Through the supplementary system, ...

2001-03-01

209

EM-MWD technology; EM-MWD system jitsuyoka gijutsu  

Energy Technology Data Exchange (ETDEWEB)

A project on the title is a special study of TRC (Technology Research Center) Japan National Oil Corporation, which aims at developing a system collecting many data near well bottom while drilling. The project is a 3-year project from 1993 to 1995 succeeding to results of a project on real-time drilling control technology which was finished in fiscal 1992. This paper is a record in fiscal 1993. In 1993, the first year, TRC starts a joint study with relational enterprises aiming at utilizing an EM-MWD (electromagnetic-measurement while drilling) system practically. Based on the past fruit of the study, the EM-MWD system was applied to an highly inclined well or a horizontal well. A total system was constructed, which improved electromagnetic radiation transmission efficiency, and reliability, and workability. An electromagnetic radiation receiver system for an offshore drilling rig ...

1994-10-31

210

A study of the effects of scattered radiation on radiographic quality and methods of elimination of such radiation  

International Nuclear Information System (INIS)

Many mechanical parts are subjected to stresses and strains that may eventually lead to their failure. In order to prevent the costly delays associated with equipment down-time, many parts have to be tested for weaknesses and defects when machinery is constructed or dismantled for maintenance. These procedures are known as Non-Destructive Testing (NDT) methods. Five types of non-destructive testing methods routinely used are radiographic testing, ultrasonic testing, magnetic particle inspection, liquid penetrant testing and eddy current testing. Out of these five techniques industrial radiography plays an important role in non-destructive testing to reveal interior defects in materials. In radiography almost two-thirds of the radiation reaching the film is scattered radiation which does not form the image of defects. Scattered radiation generated inside and outside a material has a very large effect on sensitivity of flaw detection since it reduces image contrast. ...

1998-02-01

211

Study on quality assurance for high-level radioactive waste disposal project  

International Nuclear Information System (INIS)

The U.S. Department of Energy (DOE) has developed comparatively detailed quality assurance requirements for the high-level radioactive waste disposal systems. Quality assurance is recognized as a key issue for confidence building and smooth implementation of the HLW program in Japan, and Japan is at an initial phase of repository development. Then the quality assurance requirements at site research and site selection, site characterization, and site suitability analysis used in the Yucca Mountain project were examined in detail and comprehensive descriptions were developed using flow charts. Additionally, the applicability to the Japan high-level radioactive waste disposal project was studied. The examination and study were performed for the following QA requirements: The requirements that have the relative importance at site research and site selection, site characterization, and site suitability ...

2005-03-01

212

How does one develop the right quality assurance program for waste management projects?  

International Nuclear Information System (INIS)

The quality assurance requirements in use today for radioactive waste facilities, geologic repositories and hazardous waste projects were developed initially for the nuclear power plant industry, and their intent is being applied by regulations and guidance documents to radioactive and hazardous waste programs. The wording of the NRC quality assurance requirements in Appendix B of 10CFR50, the related guidance documents and the industry's ANSI/ASME NQA-1 were developed over a period of several years to address quality assurance for the design and construction of the complex and interactive systems to produce electrical power using nuclear fuel. Now, those same documents are the basis for the quality assurance requirements and guidance for waste management facilities and repositories. The intent of Appendix B of 10CFR50 and NQA-1 can easily be applied to waste projects, providing one ...

1988-10-03

213

Environmental Restoration Remedial Action quality assurance requirements document  

International Nuclear Information System (INIS)

This document defines the quality assurance requirements for the US Department of Energy-Richland Operations Office Environmental Restoration Remedial Action program at the Hanford Site. The Environmental Restoration Remedial Action program implements significant commitments made by the US Department of Energy in the Hanford Federal Facility Agreement and Consent Order entered into with the Washington State Department of Ecology and the US Environmental Protection Agency. This document combines quality assurance requirements from various source documents into one set of requirements for use by the US Department of Energy-Richland Operations Office and other Environmental Restoration Remedial Action program participants. This document will serve as the basis for developing Quality Assurance Program Plans and implementing procedures by the participants. The requirements of this document will be applied to activities affecting ...

214

Acid-deposition research program. Volume 2. Design of the emission inventory: emission inventory of sulfur oxides and nitrogen oxides in Alberta  

Energy Technology Data Exchange (ETDEWEB)

To predict air quality properly at a given location, it is necessary to identify all emission sources that will have significant impact at that location. Furthermore, the atmospheric pollutants that are emitted by these sources must be identified and quantitatively characterized. Once the air-quality predictions have been made, it is desirable to have some historical air-quality data for comparison. An efficient means of obtaining this information is through the use of detailed emission inventories and an inventory of air-quality-monitoring stations. Therefore, as part of the Alberta Government/Industry Acid Deposition Research Program (ADRP), three comprehensive inventories have been developed, namely: a sulfur dioxide (SO/sub 2/) emission inventory, a nitrogen oxides (NOx) emission inventory, and an inventory of air-quality-monitoring stations. Volume 2, Design of the Emission ...

1987-11-01

215

Withania somnifera Improves Semen Quality in Stress-Related Male Fertility  

UK PubMed Central (United Kingdom)

Stress has been reported to be a causative factor for male infertility. Withania somnifera has been documented in Ayurveda and Unani medicine system for its stress-combating properties....Full Text Available

2011-01-01

216

NAME=\\  

Wastenet

...Quality = $290,604 to improve permit compliance and appropriate preservation of wetlands by providing a spatial dataset to locate individual wetland permits on a property using high resolution imagery within specific regions of Virginia; this data set will be compared with the permit Comprehensive Environmental Database System that is currently used ...

217

Is the Kaiser Permanente model superior in terms of clinical integration?: a comparative study of Kaiser Permanente, Northern California and the Danish healthcare system  

UK PubMed Central (United Kingdom)

BackgroundIntegration of medical care across clinicians and settings could enhance the quality of care for patients. To date, there is limited data on the levels of integration in...Full Text Available

218

Development of a Coke-Free Cupola Furnace. Energy Conserving Shaft Furnace for Iron Materials. Final Report.  

Science.gov (United States)

Coke-fired cupola furnaces were improved and made suitable for the production of high-quality casting melts by numerous additional devices. Moreover, they were equipped with environmental protection systems with numerous dust separation devices and afterb...

1986-01-01

219

Customizing systemic therapy in patients with advanced non-small cell lung cancer  

UK PubMed Central (United Kingdom)

Lung cancer is the leading cause of cancer deaths worldwide. Standard chemotherapy has been shown to improve quality of life and has a modest influence on overall survival. This modest improvement in...Full Text Available

2011-07-01

220

CERES BDS Quality Summaries - Atmospheric Science Data Center - NASA  

Science.gov (United States)

Nov 18, 2010 ... Roughly speaking, the fidelity interval we quote is a "3 sigma" value. ... surface of the foremost quartz filter which is then chemically altered by ... ( CERES) scanner point accuracy using a coastline detection system", ...

221

Air shifting diffusion; Diffusion d'air par deplacement  

Energy Technology Data Exchange (ETDEWEB)

The technique of air diffusion by shifting presents several advantages in terms of thermal comfort, indoor air quality and energy conservation. This book presents the principle, dimensioning, and implementation of air shifting diffusion systems. (J.S.)

2001-07-01

222

A Wireless Health Outcomes Monitoring System (WHOMS): development and field testing with cancer patients using mobile phones  

UK PubMed Central (United Kingdom)

BackgroundHealth-Related Quality of Life assessment is widely used in clinical research, but rarely in clinical practice. Barriers including practical difficulties administering...Full Text Available

223

Systems Analysis of Safeguards Effectiveness in a Uranium Conversion Facility  

Energy Technology Data Exchange (ETDEWEB)

The U.S. Department of Energy (DOE) is interested in developing tools and methods for potential U.S. use in designing and evaluating safeguards systems. For this goal several DOE National Laboratories are defining the characteristics of typical facilities of several size scales, and the safeguards measures and instrumentation that could be applied. Lawrence Livermore National Laboratory is providing systems modeling and analysis of facility and safeguards operations, diversion path generation, and safeguards system effectiveness. The constituent elements of diversion scenarios are structured using directed graphs (digraphs) and fault trees. Safeguards indicator probabilities are based on sampling statistics and/or measurement accuracies. Scenarios are ranked based on value and quantity of material removed and the estimated probability of non-detection. Significant scenarios, especially those involving timeliness or randomly ...

2004-06-16

224

Evaluation of measuring data of small photovoltaic power systems within the framework of the German Federal-State 1000 Roofs PV programme. Final report; 1000-Daecher Mess- und Auswerteprogramm. Auswertung der Messdaten von photovoltaischen Kleinanlagen im Rahmen des Bund-Laender-1000 Daecher-Photovoltaik-Programms. Wissenschaftlicher Endbericht  

Energy Technology Data Exchange (ETDEWEB)

Within the framework of the German Federal-State 1000 Roofs Photovoltaic Programme monthly measuring data and verbal comments on the PV system operation (reports on failures and defects) have been collected, stored in a databank and evaluated for the period 1991 to 1997 for a differing number of PV systems. In addition to this came along data of initially 100, then 40 intensively measured systems. The results of the measuring data evaluation as well as the results of further accompanying research projects to the Federal-State 1000 Roofs Photovoltaic Programme (e.g. low energy yield analysis, on-site inspections and measuring of nominal powers) are summarised. Starting from the gained results, conclusions and recommendations are given for the design, installation and operation for future grid-connected PV-systems. Also it is pointed to the remaining need for optimisation and R and D. ...

1998-10-16

225

Remote on-board coal quality sensing techniques in coal cutting and handling systems  

Energy Technology Data Exchange (ETDEWEB)

A review of the literature was undertaken to determine the potential for development of instrumentation for on-board remote sensing of coal quality. This review report acts as an inventory of commercially available techniques being tested or under development, particularly in the areas of the cutting horizon measurement methods associated with longwall mining equipment and coal/waste monitoring techniques in coal handling systems. While technology is available which can discriminate rocks from coal on a conveyor belt, the literature indicates that this hardware has yet to be adapted to continuous surface mining machines. 23 refs., 18 figs.

1987-09-01

226

Evaluation of the chest radiography using Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Chest radiograms obtained by using Fuji Computed Radiography (FCR) system were compared to conventional film/screen radiograms. The FCR images showed better image quality in diagnostic information than the conventional chest images. In FCR, the radiation exposure to patient for chest examination could be reduced up to one tenths of conventional chest examination. The main advantages or FCR were considered to depend on the contrast processing and frequency processing properties. The use of FCR in clinical work may improve both diagnostic quality and radiation exposure.

1991-12-01

227

Integrity of feedwater and main steam piping in KWU light water reactor plants  

Energy Technology Data Exchange (ETDEWEB)

New standard catalogs for piping, supports, and valves have been introduced by Kraftwerk Union (KWU) for the first time in its Convoy series of PWR plants. These catalogs, underlying regulatory codes, and newly developed KWU specifications are described. Feedwater and main steam piping systems within the containment, including pipe supports and valves, are used to demonstrate the high quality level of piping technology achieved in the Federal Republic of Germany. Such quality standards ensure the integrity of single components as well as of the entire system, so that, under certain conditions, pipe whip restraints against postulated breaks have become unnecessary. The quality aspects apply basically for both PWR and BWR plants of KWU.

1986-07-01

228

The Status of Korea-IAEA Enhanced Cooperation on the Spent Fuel Transfer to Dry Storage in CANDU Reactors  

Energy Technology Data Exchange (ETDEWEB)

Based on the enhanced cooperation between Republic of Korea (ROK) and International Atomic Energy Agency (IAEA), IAEA installed new safeguards equipment (Unattended Monitoring System, UMS) at Wolsung unit 2 on January, 2005. The UMS was utilized in parallel with traditional human surveillance during the transfer campaign of Wolsung unit 2 (7 March - 22 July). Installation of UMS at all Wolsung units will be decided on the basis of the result of this test. The transfer campaign with UMS at Wolsung units 2 and 4 was started from September 1, 2006 at the same time. Implementation of UMS to the transfer campaign in Wolsung site will be considerably reduced the IAEA's inspection effort and burden of operator.

2006-07-01

229

The Status of Korea-IAEA Enhanced Cooperation on the Spent Fuel Transfer to Dry Storage in CANDU Reactors  

International Nuclear Information System (INIS)

Based on the enhanced cooperation between Republic of Korea (ROK) and International Atomic Energy Agency (IAEA), IAEA installed new safeguards equipment (Unattended Monitoring System, UMS) at Wolsung unit 2 on January, 2005. The UMS was utilized in parallel with traditional human surveillance during the transfer campaign of Wolsung unit 2 (7 March - 22 July). Installation of UMS at all Wolsung units will be decided on the basis of the result of this test. The transfer campaign with UMS at Wolsung units 2 and 4 was started from September 1, 2006 at the same time. Implementation of UMS to the transfer campaign in Wolsung site will be considerably reduced the IAEA's inspection effort and burden of operator.

2006-11-02

230

Induction motor for tunnel exhauster; Tunnel haifukiyo yudo dendoki  

Energy Technology Data Exchange (ETDEWEB)

A totally-enclosed, fan-cooled, rib-cooled type induction motor is adopted for an exhauster which is to be installed in a ventilation station for dust catcher in a tunnel. It has the highest capacity in Japan for the above purpose, and is provided with a cooling fan inside to recirculate cooled air, thereby improving cooling efficiency and reducing size and weight. Three-row combined angular ball bearings are used as the thrust bearings, and grease lubrication system is adopted to simplify the inspection/maintenance works. It is to be delivered to Japan Highway Public Corporation's Shizuoka Construction Bureau, Yaizu site office. Its electric specifications are 455 kW, 440 V, 890 A and 510 rpm, and its mechanical specifications are thrust load: 16 kN and impeller load: 7.2 kN. (translated by NEDO)

2000-01-10

231

Flywheel rotor and containment technology development, FY83  

Energy Technology Data Exchange (ETDEWEB)

The Department of Energy decided to terminate the Flywheel Rotor and Containment Technology Development project during FY 1983. Activities this year included fabrication, inspection, and test evaluation of rotor and containment structures. A peak energy of 700 Wh was stored at an energy density of 70 Wh/kg. In cyclic tests, 10,000 cycles from design speed to half speed were logged without failure. The first test of a lightweight containment structure indicates the need for additional development. In complementary studies, production cost estimates were made for three flywheel designs. In a cooperative program with the University of Wisconsin, work began on construction of a flywheel/continuously variable transmission/heat engine car which promises fuel economy improvements of up to 100%. Suggestions are made for the direction of future work when interest in flywheel system reappears.

1983-09-12

232

A novel electrochemical alkylation of aniline with methanol over Zn/Cu salts modified kaolin  

British Library Electronic Table of Contents (United Kingdom)

A novel liquid phase alkylation of aniline with methanol over Zn/Cu salts modified kaolin assisted with a pair of porous carbon electrode in slurry-bed reactor under constant current intensity, room temperature and atmospheric pressure was reported. The Zn/Cu salts modified kaolin catalysts were synthesized and characterized by infrared spectrometer (IR), powder X-ray diffraction (XRD) and scanning electron microscopy (SEM), which showed that the transition metals were completely supported on kaolins structure and formed a pored one. The effect parameters, such as initial pH, electrolysis time, metal ratio with kaolin and salts composition in this electrochemical catalytic system, were studied. The procedure was inspected by ultraviolet-visible spectrum (UV-vis), and the product distributi...

2008-01-01

233

Stabilization of synchrotron radiation beam at HASYLAB  

Energy Technology Data Exchange (ETDEWEB)

At DORIS II/HASYLAB a vertical beam position control system is in regular operation. It controls the position and angle of a photon beam simultaneously, and can stabilize beam movements up to frequencies of 0.1 Hz. To suppress beam vibrations up to 50 Hz and above, a prototype beam stabilization system for these frequencies was built and tested successfully. The present beam oscillations at the HASYLAB beamlines are explained, the quality of the beam position control system and the results of the prototype test are presented.

1989-07-01

234

Interventional MR imaging: Clinical results obtained with a 1.5 Tesla system  

International Nuclear Information System (INIS)

The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.).

235

Characterization of Adaptive Optics at Keck Observatory  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the adaptive optics (AO) system at Keck Observatory is characterized. The AO system is described in detail. The physical parameters of the lenslets, CCD and deformable mirror, the calibration procedures and the signal processing algorithms are explained. Results of sky performance tests are presented: the AO system is shown to deliver images with an average Strehl ratio of up to 0.37 at 1.59 {micro}m using a bright guide star. An error budget that is consistent with the observed image quality is presented.

2003-07-24

236

Achieving more reliable operation of turbine generators at nuclear power plants by improving the water chemistry of the generator stator cooling system  

British Library Electronic Table of Contents (United Kingdom)

Ways of improving the water chemistry used in the turbine generator stator?s cooling systems at Russian nuclear power plants are considered. Data obtained from operational chemical monitoring of indicators characterizing the quality of cooling water in the turbine generator stator cooling systems of operating power units at nuclear power plants are presented.

2011-01-01

237

Calendar year 1993 groundwater quality report for the Chestnut Ridge Hydrogeologic Regime Y-12 Plant, Oak Ridge, Tennessee. 1993 Groundwater quality data interpretations and proposed program modifications  

Energy Technology Data Exchange (ETDEWEB)

This groundwater quality report (GWQR) contains an evaluation of the groundwater quality data obtained during the 1993 calendar year (CY) at several hazardous and non-hazardous waste management facilities associated with the US DOE Y-12 Plant located on the DOE Oak Ridge Reservation (ORR) southeast of Oak Ridge, Tennessee. The groundwater quality data are presented in Part 1 of the GWQR submitted by Martin Marietta Energy Systems, Inc. to the Tennessee Department of Environment and Conservation (TDEC) in February 1994. Groundwater quality data evaluated in this report were obtained at several hazardous and non-hazardous waste management sites located within the Chestnut Ridge Hydrogeologic Regime (Chestnut Ridge Regime). The Chestnut Ridge Regime encompasses a section of Chestnut Ridge south of the Y-12 Plant and is one of three hydrogeologic regimes defined for the purposes of ...

1994-09-01

238

Study of Water Quality Value in Sub of the Stream Area of Cisadane Rivers Upstream as Reference Area Based on Macro invertebrate Composition  

International Nuclear Information System (INIS)

Specific structure of biota community condition can used as indicator for the ecosystem stability value or the waters pollution level where the aquatic biota exist. the macro invertebrates as bio indicator organism can used to assess the upper Cisadane Sub River Basin water quality. The grouping and calculation result from family number, Ept presences (sensitive macro invertebrate), Diversity index (H"'), DO value and TOC value showed 5 criteria of water quality as reference site. This criteria is used to determine water quality level from ten branches of rivers in the upper Cisadane Sub River Basin, Cijeruk districts. The biotic index calculation for ASPT (Average Score Per Taxon) and T and T (index Trihadiningrum and Tjindronegoro) is used to asses water quality based on macro invertebrate composition indicator. Both biotic index system support and give the similar evaluation to ...

2001-11-01

239

Supervision of construction, quality assurance, operating experience in the new heating power station II; Bauueberwachung, Qualitaetssicherung, Betriebserfahrungen mit dem neuen Heizkraftwerk II  

Energy Technology Data Exchange (ETDEWEB)

After 3 years of construction the trial run of the heating power station HKW 2 ended in November 1997 on time. No extraordinary damage occured during construction, assembly or commissioning. The plant has been operating according to schedule since November 1997. A brief inspection carried out in the summer of 1998 in order to assess warranty claims showed no damage to any part except one valve. Experience shows that all aforementioned activities were necessary. The paper reports about success and negative experience. Certification according to DIN EN ISO 9000ff., however, affords to guarantee of high-quality construction. Builders of such plants therefore need to set up their own quality assurance centre and ensure its technical competence. If necessary,additional experts should be called in.Quality assurance costs for HKW 2 came to about 0.5-0.6 percent of total costs. In view of the success and long ...

1998-07-01

240

Evaluation of structural integrity of crossover leg piping system with dynamic whip restraints  

Energy Technology Data Exchange (ETDEWEB)

Interference between the crossover leg of the Reactor Coolant System(RCS) and the Pipe Whip Restraints(PWR) has brought a degradation issue of the integrity of the Reactor Coolant System in Westinghouse type Nuclear Power Plants(NPPs) of Korea. According to the gap inspection carried out during planned overhaul (year 2000), interference between the crossover leg and the PWR was found in each RCS loop. This plant has had the high vibration problem on the RC pump 'B'. The reason for the high vibration in the RC pump 'B' had been massively surveyed and it was found that the crossover leg of RCS contacted with the PWR in hot condition. Since the contact between the crossover leg and the PWR changes the dynamic characteristics of the piping system for the RCS, this is considered as one reason for the high vibration. And a possibility of overstress on the crossover leg due ...

2001-07-01

241

Demonstration of realtime radiography on pipeline girth welds: Final report  

Energy Technology Data Exchange (ETDEWEB)

Conventional radiography has been the accepted nondestructive testing (NDT) method used for many years to either ''accent'' or ''reject'' a field weld in the pipeline industry. However, conventional radiography requires the expense of film, developing chemicals, and manpower for film development. It also normally has a delay of 2 hours or more between when the weld was radiographed and when the radiographic film of the weld is available for interpretation. Over the last few years, a newer approach to performing radiographic testing, called ''realtime'' radiography, has been used in several different types of field inspection operations. The realtime radiography system forms the image with optical imaging in lieu of photographic film. Objectives of this project were: (Task 1) Integration of realtime x-ray system ...

1988-09-01

242

Integrated Safeguards proposal for Finland. Final report on Task FIN C 1264 of the Finnish Support Programme to IAEA Safeguards  

Energy Technology Data Exchange (ETDEWEB)

The IAEA has requested several member states to present their proposal of the application of the Integrated Safeguards (IS) system in their nuclear facilities. This report contains a IS proposal for Finland prepared under the Task FIN C 1264 of The Finnish Support Programme to IAEA Safeguards. The comprehensive safeguards system of the International Atomic Energy Agency (IAEA) has been one of the main tools in the fight against nuclear proliferation since the entry-into-force of the Nuclear Non-proliferation Treaty three decades ago. In the 1990s some of the inherent weaknesses of this so-called traditional safeguards system were revealed first in Iraq and then in North Korea. Therefore, the member states of the LAEA decided to give the Agency additional legal authority in order to make its control system more effective as well as more efficient than before. This was accomplished by the approval of the ...

2000-08-01

243

Radiant heating and cooling, displacement ventilation with heat recovery and storm water cooling: An environmentally responsible HVAC system  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the design, operation, and performance of an HVAC system installed as part of a project to demonstrate energy efficiency and environmental responsibility in commercial buildings. The systems installed in the 2180 m{sup 2} office building provide superior air quality and thermal comfort while requiring only half the electrical energy of conventional systems primarily because of the hydronic heating and cooling system. Gas use for the building is higher than expected because of longer operating hours and poor performance of the boiler/absorption chiller.

1998-12-31

244

Sound climate installations. Gezonde klimaatinstallaties  

Energy Technology Data Exchange (ETDEWEB)

An uncomfortable thermal climate, draft complaints and a bad airquality are often related to the climate installation. To avoid badfunctioning of the system a number of preconditions has to be fulfilledwith regard to design, planning and execution, adjustments, completion,control, maintenance and management of the installations. First threetypes of health problems in buildings are shortly discussed: buildingrelated illness, sick building syndrome and building or installationrelated complaints. Then some functions of the climate installationsare described: air filtration, filter classes and filter quality, aswell as investment costs for better filters. Next the causes for thecomplaints are dealt with: air conditioning, ventilation, air quality,and temperatures. Subsequently health affecting aspects in relation tothe climate systems are discussed: outdoor air pollution,microorganisms, bacteria (legionella ...

1989-10-01

245

Reduction of fluoroscopic exposure for the air-contrast barium enema  

Energy Technology Data Exchange (ETDEWEB)

In a fluoroscopic imaging system, image quality and patient dose are both affected by the optical system linking the image intensifier with the video camera. The effect on patient exposure of increasing the optical iris aperture size over that required for other procedures performed on the same imaging system was investigated for the air-contrast barium enema examination. Using a large-area transmission ionisation chamber to monitor the Roentgen-area-product of entrance exposure, a decrease in fluoroscopic radiation of greater than 50% was clinically documented for a fluoroscopic system utilising kVp and mA variable automatic brightness control. For this iris change, the video image was of acceptable quality for positioning and monitoring the patient, and no deleterious effect was detected in the conduct of the air-contrast exam. The availability of a ...

1983-11-01

246

Measuring e-CRM service quality in the library context: a preliminary study  

British Library Electronic Table of Contents (United Kingdom)

Purpose - Customer relationship management (CRM) indicates a comprehensive strategy and an interactive process intended to achieve an optimum balance between corporate investment and the satisfaction of customer needs to generate the maximum profit. E-CRM refers to CRM using internet technology plus a database, OLAP, data warehouse, data mining, etc. In order to gain an understanding of the efficiency of implementing an e-CRM system within the library context, to develop theoretically and empirically an evaluation process for the e-CRM system and survey its impact on service quality, a pilot scheme was initiated in 2004. The pilot scheme was to design and implement an e-CRM prototype system for a particular academic library in Taiwan and to survey the system's performances. This paper aims...

2008-01-01

247

Electromagnetic compatibility and power quality: engineering contribution; Compatibilite electromagnetique et qualite de l`onde: contribution de l`ingenieur-conseil  

Energy Technology Data Exchange (ETDEWEB)

Problems relating to electromagnetic compatibility and power quality were discussed, combined with a discussion of the role that consulting engineers can play in resolving them. The need for the consulting engineer to be aware of design specifications of equipment was considered essential. Similarly, the interrelationship between installations using variable speed drives, halogenous lighting systems, capacitor banks, high-voltage power lines, power transformers, etc., and the need for familiarity with the operating characteristics of different types of power systems were stressed as key ingredients to success in ascertaining events and causes of equipment failure or power system problems on the network. The main sources of disturbances, impact of voltage variations, the importance of controlling voltage imbalance, and system protection were summarized. 4 figs.

1996-08-01

248

Recent uses of robotics for remote inspection and maintenance  

International Nuclear Information System (INIS)

This paper documents some of the recent uses of robotics for inspection and maintenance activities in Ontario Hydro's nuclear power plants in areas other than fuel channels and steam generators. 7 figs.

1992-11-22

249

Radiographic experience with power transmission equipment  

Energy Technology Data Exchange (ETDEWEB)

This paper describes radiography as one of the most efficient and cost effective methods for inspecting electric cabls. Details of one project in particular, i.e., the inspection of high-pressure, oil-filled, pipe-type cables (HPOF) are given. 2 refs.

1980-01-01

250

Eddy Current Inspection of Mildly Ferromagnetic Tubing.  

Science.gov (United States)

The past decade has seen the development of eddy current probes for inspection of the mildly ferro-magnetic alloy Monel 400. Due to the rapid advances in permanent magnet technology similar probes have been upgraded to magnetically saturate, and hence ins...

1984-01-01

251

Digital image precessing for neutron television fluoroscopic system and its application to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are ...

1984-09-01

252

Digital image precessing for neutron television fluoroscopic system and its application to neutron computed tomography  

International Nuclear Information System (INIS)

The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are ...

1984-01-01

253

Improving safety and quality: how can education help?  

Science.gov (United States)

National efforts to improve the quality and safety of health care present challenges for medical education and training. Today's doctors need to be skilled communicators who know how to identify, prevent and manage adverse events and near misses, how to use evidence and information, how to work safely in a team, how to practise ethically, and how to be workplace teachers and learners. These competencies (knowledge, skills and attitudes) are set out in the National Patient Safety Education Framework (NPSF) of the Australian Council for Safety and Quality in Health Care. The NPSF is designed to help medical schools, vocational colleges, health organisations and private practitioners develop curricula to enable health professionals to work safely. The NPSF describes what doctors (depending on their level of knowledge and experience) can do to demonstrate competencies in a range of quality and safety activities. Medical ...

2006-05-15

254

SPECIAL EDDY CURRENT PROBES FOR HEAT ...  

Science.gov (United States)

... Accession Number : ADD326926. Title : SPECIAL EDDY CURRENT PROBES FOR HEAT EXCHANGER INSPECTION. Corporate Author : ...

1986-11-01

255

Multiple-Element Eddy Current Probes for Enhanced ...  

Science.gov (United States)

... Accession Number : ADD335251. Title : Multiple-Element Eddy Current Probes for Enhanced Inspection,. Corporate Author : ...

1993-07-01

256

Conflict among the circuits: who may conduct inspections under the Clean Air Act  

Energy Technology Data Exchange (ETDEWEB)

Bunker Hill Co. v. Environmental Protection Agency (EPA) challenged EPA's right to make on-site inspections. A review of the arguments in three Circuit Court Cases shows that the inspection would be meaningless if the chemical company retained exclusive control over inspections and the generated information, but neither court held the company in contempt for refusing admission to inspectors. Industry's claim that on-site monitoring is unconstitutional and the compromises in lawsuits suggest a lack of compliance by both industry and EPA in monitoring regulations. Congress needs to rewrite less-ambiguous regulations. 59 references. (DCK)

1983-01-01

257

Characterization of eddy current probes used in steam generator tubes inspection  

International Nuclear Information System (INIS)

In in-service inspection of steam-generator tubes, the need for reproducibility of the measurement results and for comparison of these results over two successive inspections has led EDF to specify the main characteristics of the eddy-current probes and to design equipment to measure them. This equipment is presented here and the electrical and magnetic results are correlated with those obtained by testing tubes with reference defects.

1985-02-01

258

Characterization of Eddy Current probes used in steam generator tubes inspection  

International Nuclear Information System (INIS)

In in-service inspection of steam-generator tubes, the need for reproducibility of the measurement results and for comparison of these results over two successive inspections has led EDF to specify the main characteristics of the Eddy-Current probes and to design equipment to measure them. This equipment is presented here and the electrical and magnetic results are correlated with those obtained by testing tubes with reference defects. 5 refs.

1985-02-01

259

In-situ examination of turbine components (blade roots, rotor steeple grooves and disk-blade rim attachments) of low-pressure steam turbine, using phased array technology  

Energy Technology Data Exchange (ETDEWEB)

A feasibility study test and 3 field trials were performed at Darlington NGS in 1996, 1999 and 2000 on ABB LP turbines. The scope of these trials was to commission in-situ automatic phased array systems capable to inspect blade roots and rotor steeples of L-0 and L-1 rows. GE disk-blade rim attachments were inspected at Bruce B nuclear station, in fall of 1999. The automated ultrasonic phased array technology is capable of high-speed rate and reliable detection and sizing. The capability demonstration was performed on mock-ups and reference blocks, using EDM notches. A custom built UT simulation software: Imagine 3D interfaces with SimScan to generates the spreadsheets/charts with target and probe coordinates and ultrasonic path and angles (refracted and skew) to hit the reference target. Examination of L-0 blade and rotor steeple grooves was performed with 2 phased array systems under networking. Data ...

2000-07-01

260

Quantum Teleportation with Continuous Variables: a survey  

CERN Document Server

Very recently we have assisted to a new development of quantum information, the so-called continuous variable (CV) quantum information theory. Such a further development has been mainly due to the experimental and theoretical advantages offered by CV systems, i.e., quantum systems described by a set of observables, like position and momentum, which have a continuous spectrum of eigenvalues. According to this novel trend, quantum information protocols like quantum teleportation have been suitably extended to the CV framework. Here, we briefly review some mathematical tools relative to CV systems and we consequently develop the concepts of quantum entanglement and teleportation in the CV framework, by analogy with the qubit-based approach. Some connections between teleportation fidelity and entanglement properties of the underlying quantum channel are inspected. Next, we face the study of CV quantum ...

2006-01-01

261

Full autonomous monitoring tools inside nuclear reactor building  

Energy Technology Data Exchange (ETDEWEB)

In this paper, we define, design and test a radiation tolerant autonomous monitoring tool for nuclear embedded applications. The goal of the instrumentation system was to record the values of some parameters such as dose, temperature or vibrations appearing inside the containment building of nuclear power plants. The knowledge of these parameters will be a good help for predictive maintenance of the power plant components. For the design of the monitoring tool, we rely on commercial-off-the-shelf (COTS) low power electronic components to use battery-supplied power. A large amount of components starting from discrete transistors or logic units to memories and micro-controllers was associated to define and design a prototype. We then confirm the environment conditions tolerance estimated to up to 2 kGy of total dose and 80 C for temperature by on-line irradiation experiments for individual components and functions and prototypes. Two different sets of about 60 ...

2009-07-01

262

Standard review plan for the review of environmental restoration remedial action quality assurance program plans  

International Nuclear Information System (INIS)

This plan establishes both the scope of the review and the acceptance criteria to be utilized for the review of Quality Assurance Program Plans (QAPPs) developed in accordance with the requirements of DOE/RL-90-28. DOE/RL-90-28, the Environmental Restoration Remedial Action Quality Assurance Requirements Document (QARD) defines all quality assurance (QA) requirements governing activities that affect the quality of the Environmental Restoration Remedial Action (ERRA) program at the Hanford Site. These requirements are defined in three parts, Part 1 of Quality Management and Administration tasks, Part 2 for Environmental Data Operations, and Part 3 of the Design and Construction of items, systems, and facilities. The purpose of this document is to identify the scope of the review by the DOE Field Office, Richland staff, and establish the acceptance criteria (Parts ...

263

Exploration of exposure dose optimization for pelvic examination in direct digital radiography with a phantom  

International Nuclear Information System (INIS)

Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly different. Conclusion: The image quality of direct digital radiography ...

2005-10-01

264

CAR International. A simple model to determine city street air quality  

Energy Technology Data Exchange (ETDEWEB)

Based on wind tunnel experiments, theoretical considerations and measurements the dispersion model CAR (Calculation of Air pollution from Road traffic) has been developed for determining air quality in city streets. CAR International is a simple parameterized model using readily available input data and calculating annual percentile values and average concentrations close to streets (at the kerb side) for non-reactive air pollutants and NO{sub 2}. Originally the model was set up for the Dutch situation (traffic, meteorology) with a system of fixed parameters. In order to extend its application to other countries the program has been made more flexible and user friendly. User defined system data can now be changed interactively, such as emission factors of passenger cars and trucks, fraction of directly emitted NO{sub 2}, city and regional background concentration, and average regional wind speed. The accuracy of the model ...

1995-06-22

265

Solid suspension in stirred tanks: UVP measurements and CFD simulations  

British Library Electronic Table of Contents (United Kingdom)

Abstract Suspension of solids in stirred reactor is widely used for catalytic reactions, dissolution, etc. Quality of solid suspension is an important parameter required for the reliable design, optimum performance, and scale up of the system. Quality of suspension depends on local characteristics of solid velocity and hold up profiles. The present work was focused on investigating quality of solid suspension using ultrasound velocity profiler (UVP) measurements and CFD simulations. The slip velocity measurements carried out with UVP were used to evaluate different drag correlations used in CFD simulations. Results discussed in this work would be useful for extending the applications of CFD models for simulating large stirred slurry reactors.

2011-01-01

266

On-farm water management in saline groundwater area under scarce canal water supply condition in the Northwest India  

British Library Electronic Table of Contents (United Kingdom)

The study investigates the possibility of enhancing crop water productivity in the parts of Northwest India where groundwater quality is marginal and canal water supply is severely scarce. Soil, Water, Atmosphere and Plant (SWAP) model was calibrated and validated in three farmers' fields with varying canal water availability and groundwater quality in the Kaithal Irrigation Circle of the Bhakra Canal system, Haryana. On the basis of predicted and observed soil water content, pressure heads, salt concentration at 2 week intervals and crop yields, the model was found suitable for use in the region. A few nomographs were prepared to provide a graphical method to predict the effect of different combinations of water quality and depth of water application on crop yield and soil salinity and to...

2008-01-01

267

Natural gas and quality of fuels for the reduction of atmospheric pollution  

International Nuclear Information System (INIS)

The production of atmospheric pollutants in combustion processes depends on plant characteristic, combustion conditions and fuel quality. The influence of fuel quality on the emission of sulphur oxides, nitrogen oxides, carbon monoxide, dust and carbon dioxide and on the emission of some toxic pollutants, such as heavy metals and polycyclic aromatic hydrocarbons, is analysed. The comparison between the emission limits, fixed by the Italian legislation, and the uncontrolled pollutant emissions, produced by fossil fuel combustion in power plants and industrial use, shows that, in order to comply with the limits, a reduction of pollutant emissions is required through the use of abatement systems and cleaner fuels where natural gas has a primary role. The use of cleaner fuels is particularly required in heating plants and appliances for the residential sector, where the development of new gas technologies further increases the ...

1998-01-01

268

Design of automatic monitoring network for the water quality management of river basin  

Energy Technology Data Exchange (ETDEWEB)

In designing automatic water quality monitoring networks for a river basin, determination of measurement locations and items is critical to the effectiveness of the total system. In this paper we studied how to decide these two design factors when a monitoring network is designed for the purpose of water quality surveillance and emergency alarm. For measurement locations, candidate sites are chosen based on the intake amount for water supply and the point sources of contamination. Then, detailed locations are decided according to the contaminant flow distance. As for measurement items, characteristics and the accident history of water pollution in the basin must be taken into account. Considering economic aspects, we proposed a two-stage measurement plan: basic components for all locations and selective ones variable for different locations. Proposed methodology is demonstrated through a case study for Nak-dong River Basin. ...

1996-04-30

269

Ventilation concept, indoor air quality and measurement results in the ``Passivhaus Kranichstein``  

Energy Technology Data Exchange (ETDEWEB)

The ``Passivhaus Darmstadt-Kranichstein`` is a 4 unit terrace house with an extremely low total annual energy consumption of less than 32 kWh/m{sup 2} of living area, thereof about 12 kWh are needed for room heating. The determining factors for the low consumption are the superinsulation, airtightness of the thermal envelope in combination with a highly efficient VAV ventilation system, and an improved window construction. The results of a detailed monitoring program allow decisive statements concerning reduction of energy consumption, relief of environment, indoor air quality, and thermal comfort. (author)

1994-12-31

270

Analysis of beam emittance in FEL (Free Electron Laser)  

International Nuclear Information System (INIS)

To achieve high efficiency for the conversion of electron kinetic energy in an electron beam to electromagnetic energy in a Free Electron Laser (FEL), it is important to improve the beam quality. And hence, it is necessary to study and minimize the emittance growth of the beam. According to the requirements for the beam quality in an FEL, the author analyzed the emittance growth caused by the jump of the electric field in an accelerator, energy increase, wakefield in a waveguide, space charge effect and distribution of particles in a beam as well as the wakefield in a deflect system etc. The author also estimated the emittance change caused by the variation of the microwave field from the gun to the first accelerator for such case.

271

A database for QA/QC in neutron activation analysis and gamma-ray spectrometry  

International Nuclear Information System (INIS)

A database has been designed for storing, retrieving and analyzing information about samples, experimental conditions and results obtained by neutron activation analysis and gamma-ray spectrometry. It has been created using Microsoft ACCESS 2002 under a Windows operating system. The database has been designed not only for saving information but also for quality assurance and quality control purposes. The structure of the relational design has been discussed and demonstrated with a new graphical feature of ACCESS 2002 called PIVOTCHART. (author)

2007-04-01

272

Monitoring processes and measuring the effectiveness of the management system  

International Nuclear Information System (INIS)

This document presents the way which the 8th principle of the quality management system 'Process approach' is applied, the principle that is identified and used by international standard ISO 9000. In order to understand the evolution of the management system requirements, as used today in different activities namely, industry, services, and nuclear activities, the authors present an evolution of the quality concept and its traceability to different standards, applicable in time. There are described the requirements of ISO 9001 standard, that represents the most widely spread model for modern organization management and the IAEA concerns related to integration of the above standard requirements into the most recent safety IAEA standard 'The Management System for facilities and activities'. The IAEA Safety Standard GS-R-3 describes a management model considering both the evolution of ...

2009-10-12

273

Simulation on energy use for mechanical ventilation and air-conditioning (MVAC) systems in train compartments  

Energy Technology Data Exchange (ETDEWEB)

Unlike the conventional automotive, modem railway trains are designed with non-openable windows; and a mechanical ventilation and air-conditioning (MVAC) system is installed in each train compartment for better indoor air quality as well as to provide a thermally comfortable environment. The ventilation rate is no doubt a critical element in the design of a MVAC system, especially in Hong Kong where the daily passenger load is extremely heavy. Earlier studies illustrated that carbon dioxide can be controlled at 1000 ppm by increasing the ventilation rate to 25.2 m{sup 3} h{sup -1}; however, it will also lead to an increase in energy consumption. In this paper, the electrical energy consumption at various ventilation rates was studied, and the cost of maintaining a low carbon dioxide level was estimated These provide solid information for the local railway companies to improve the air quality inside the ...

2000-01-01

274

Laboratory robotics systems at the Savannah River Laboratory  

International Nuclear Information System (INIS)

Many analytical chemistry methods normally used at the Savannah River site require repetitive procedures and handling of radioactive and other hazardous solutions. Robotics is being investigated as a method of reducing personnel fatigue and radiation exposure and also increasing product quality. Several applications of various commercially available robot systems are discussed involving cold (nonradioactive) and hot (radioactive) sample preparations and glovebox waste removal. Problems encountered in robot programming, parts fixturing, design of special robot hands and other support equipment, glovebox operation, and operator-system interaction are discussed. A typical robot system cost analysis for one application is given.

1983-11-16

275

Displacement ventilation in industry - a design principle for improved air quality  

Energy Technology Data Exchange (ETDEWEB)

There is very little quantitative documentation of actual improvements resulting from the installation of new general ventilation systems in industrial settings. Therefore the performance of the common mixing design principle was compared to the displacement design principle by means of an intervention study in a workshop (V = 12,000 m[sup 3]), where thermoplastics were moulded. An experimental signal-response tracer gas technique was used. In terms of supplying fresh air to the zone of occupancy the displacement system was better than the mixing system by a factor of 2. In terms of the exposure level to a simulated contaminant (tracer gas) the displacement system was better by a factor 1.5-18. (author)

1992-10-01

276

Application of the neutron television fluoroscopic system to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).

1984-10-01

277

Application of the neutron television fluoroscopic system to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter.

1984-10-01

278

An application of the neutron television fluoroscopic system to neutron computed tomography  

International Nuclear Information System (INIS)

Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).

1984-10-01

279

The Philadelphia Marriott: A convention center flagship hotel  

Energy Technology Data Exchange (ETDEWEB)

This article describes the state-of-the-art HVAC system at the Philadelphia Marriott Hotel. Thermal comfort and indoor air quality are emphasized. The system uses a hybrid gas absorption/electric centrifugal chilled water plant, variable flow pumping, water-side economizers to provide free cooling, central air handling units with air-side economizers and flow monitoring equipment.

1997-01-01

280

Neutron radiography with the cyclotron, 6  

International Nuclear Information System (INIS)

The image processing system for the dynamic neutron radiography has been developed. It is based on the hardware subset, composed by the method of the pipe-line and use of algorithm of local statistics. The processing speed per one pixel is shorter than 100 n sec and video-rate processing can be executed on it. Some image processes for improving the quality of the real-time neutron image, noise reduction and contrast stretching would be attempted by the use of this system. (author).

1988-01-01

281

Coal bibliography  

Energy Technology Data Exchange (ETDEWEB)

This report contains basic bibliographic data for reports held by Resource Management and Mining (Ministry of Energy) in its Coal Technical Information System (CTIS). This system contains a large number of published and unpublished reports relating to New Zealand's coal, peat, and oil shale resources. This material has been accumulated from a wide range of sources and is of widely varying quality.

1987-01-01

282

Applications of the phased array technique; Anwendungsmoeglichkeiten der Gruppenstrahlertechnik  

Energy Technology Data Exchange (ETDEWEB)

The application of the phased array technique was limited to heavy and thick wall components as present in the nuclear industry. With the improvement of the equipment and probes other application areas are now open for the phased array technique, e.g. the inspection of the turbine blade root, weld inspection in a wall thickness range between 12 and 40 mm, inspection of aircraft components, inspection of spot welds or inspection of concretes. The aim of the use of phased array techniques has not been changed related to the first applications, i.e. the adaptation of the sound beam to the geometry by steering the angel of incidence or the skewing angle as well as the focussing of sound fields. Due to the fact, that the new applications of the phased array techniques in some cases don't leave the laboratories for the time being, the examples of this contribution will focus ...

1999-07-01

283

Amchitka Mud Pit Sites 2006 Post-Closure Monitoring and Inspection Report, Amchitka Island, Alaska, Rev. No.: 0  

Energy Technology Data Exchange (ETDEWEB)

In 2001, the U.S. Department of Energy (DOE), National Nuclear Security Administration (NNSA/NSO) remediated six areas associated with Amchitka mud pit release sites located on Amchitka Island, Alaska. This included the construction of seven closure caps. To ensure the integrity and effectiveness of remedial action, the mud pit sites are to be inspected every five years as part of DOE's long-term monitoring and surveillance program. In August of 2006, the closure caps were inspected in accordance with the ''Post-Closure Monitoring and Inspection Plan for Amchitka Island Mud Pit Release Sites'' (Rev. 0, November 2005). This post-closure monitoring report provides the 2006 cap inspection results.

2006-09-01

284

The use of artificial neural network analysis and multiple regression for trap quality evaluation: a case study of the Northern Kuqa Depression of Tarim Basin in western China  

Energy Technology Data Exchange (ETDEWEB)

Artificial neural network analysis is found to be far superior to multiple regression when applied to the evaluation of trap quality in the Northern Kuqa Depression, a gas-rich depression of Tarim Basin in western China. This is because this technique can correlate the complex and non-linear relationship between trap quality and related geological factors, whereas multiple regression can only describe a linear relationship. However, multiple regression can work as an auxiliary tool, as it is suited to high-speed calculations and can indicate the degree of dependence between the trap quality and its related geological factors which artificial neural network analysis cannot. For illustration, we have investigated 30 traps in the Northern Kuqa Depression. For each of the traps, the values of 14 selected geological factors were all known. While geologists were also able to assign individual trap quality ...

2004-03-01

285

Development of new CAD system for steel structures of nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

IHI has developed a new Three-Dimensional Computer-Aided Design (3D-CAD) system to improve the design efficiency and quality of the steel structure of nuclear power plants. This system covers every design phase from the initial arrangement of structure to the production design sharing the same database. The system incorporates the design rules and professional expertise of designers, and enable easy and efficient design. The system can easily generate the three-dimensional data for structures, model data for stress analyses and composite arrangement data. The system has already been applied to several plants under construction and has achieved excellent results. The outline of the new CAD system is introduced. (author)

1999-09-01

286

Research and implementation of stretch-out operation in Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

Stretch-out operation mode can deepen the reactor burnup when the boron concentration is near 0 mg/L, in which the additional reactivity is introduced by the reducing of the moderator temperature and the decreasing of the load. Stretch-out is used in many nuclear power plants all over the world. The first stretch-out operation has been used for the first time in China. As a specific operation mode, which outruns the original reactor core design, the related and specialized design argument and safety analysis is required. As a consequence of the continuous or stepwise reduction of load and moderator temperature, the neurotic measurement system and the reactor control and protection system parameters should be modified specially. Based on the schedule of the electricity production, the first stretch-out operation had been carried out from March 12 to March 21 2003. It successfully avoided the overlapping between 209 and 109 ...

2006-02-01

287

Renewal of existing fossil-fired plants incorporating fully-fired combined cycle  

Energy Technology Data Exchange (ETDEWEB)

The present article describes the features of the fully-fired combined cycles and the outline of the plant. Hitachi has optimized fully-fired combined cycle systems by executing a heat recovery type combined cycle. For the fully-fired combined cycles, it is possible to raise plant efficiency through the selection of adequate gas turbine types and cycles. It is possible to apply existing boiler facilities, fuel combustion systems, and stacks. It is possible to execute civil and architectural works on existing plants in-service as well as modification works during routine inspections. The NOx increment by gas turbine unit installations can be reduced by denitration plant modifications. Examples of the fully-fired combined cycles under planning are also introduced. Furthermore, the relational technique and operational characteristics are mentioned, as for combustion characteristics under low oxygen concentration in the wind ...

1993-02-01

288

Remote replacement of TF (toroidal field) and PF (poloidal field) coils for the compact ignition tokamak  

Energy Technology Data Exchange (ETDEWEB)

The use of deuterium-tritium fuel in the Compact Ignition Tokamak will require applying remote handling technology for ex-vessel maintenance and replacement of machine components. Highly activated and contaminated components of the fusion devices auxiliary systems, such as diagnostics and RF heating, must be replaced using remotely operated maintenance equipment in the test cell. In-vessel remote maintenance included replacement of divertor and first wall hardware, faraday shields, and for an in-vessel inspection system. Provision for remote replacement of a vacuum vessel sector, toroidal field coil or poloidal field ring coil was not included in the project baseline. As a result of recent coil failures experienced at a number of facilities, the CIT project decided to reconsider the question of remote recovery from a coil failure and, in January of 1990, initiated a coil replacement study. This study focused on the ...

1990-01-01

289

Long-term reliability of amorphous alloy wound core distribution transformers  

Energy Technology Data Exchange (ETDEWEB)

In order to verify long-term reliability of amorphous alloy wound core distribution transformers, accelerated aging tests and field trials used by actual transformers were practiced. As for accelerated aging tests, short-circuit tests were added to imitate mechanical stress in operation on a utility's distribution system. As a result, even after the equivalent of 30 years, which was the normal expected transformer's life, magnetic characteristic was unchanged, so these transformers could be operated. Also, about field trials, two hundred transformers of four kinds were installed on a utility's distribution system to look into no-load characteristics. They were equipped with a mechanism to measure load current, background vibration and lightning surge current, so the influence for magnetic characteristic could be inspected. As a result, remarkable change wasn't seen even after six months.

1994-01-01

290

Eddy currents signal processing for steam generator inspection in PWR nuclear power plants; Traitement des signaux de courants de Foucault pour le controle des tubes de generateurs de vapeur dans les centrales nucleaires REP  

Energy Technology Data Exchange (ETDEWEB)

Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostics system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of these items.

1991-07-01

291

Eddy currents signal processing for steam generator inspection in PWR nuclear power plants. Traitement des signaux courants de Foucault pour le controle des tubes de generateurs de vapeur dans les centrales nucleaires REP  

Energy Technology Data Exchange (ETDEWEB)

Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostic system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of these items.

1992-01-01

292

Analysis of defect detection in steam generator tubes of FBR, under support plates and in the presence of sodium using multi-frequency eddy current algorithms  

International Nuclear Information System (INIS)

In the present paper we estimate the effect of sodium in the in-service inspection of non-magnetic steam generators tubes using eddy current technique and eddy current probes based on a differential double bobbin coil configuration. Experimental measurements of defects signals in steam generator tubes of fast breeder reactor are compared with simulations results of a two-dimensional axisymmetric finite element code to validate a reliable electromagnetic model of the system (eddy current coils, steam generator tube, defect) when there is no sodium on the outer steam generator tube surface. The electromagnetic code is used to evaluate the sodium band and sodium layer signals when a defect is located under steam generator support plate. Using a multi-frequency algorithm, its parameters are determined in the 'no sodium condition' (there is no sodium on the outer steam generator tube surface), defects signal is enhanced during eddy currents ...

2007-04-22

293

A rapid response air quality analysis system for use in projects having stringent quality assurance requirements  

International Nuclear Information System (INIS)

This paper describes an approach to solve air quality problems which frequently occur during iterations of the baseline change process. From a schedule standpoint, it is desirable to perform this evaluation in as short a time as possible while budgetary pressures limit the size of the staff available to do the work. Without a method in place to deal with baseline change proposal requests the environment analysts may not be able to produce the analysis results in the time frame expected. Using a concept called the Rapid Response Air Quality Analysis System (RAAS), the problems of timing and cost become tractable. The system could be adapted to assess other atmospheric pathway impacts, e.g., acoustics or visibility. The air quality analysis system used to perform the EA analysis (EA) for the Salt Repository Project (part of the Civilian Radioactive Waste ...

294

Indoor air quality and thermal comfort studies of an under-floor air-conditioning system in the tropics  

Energy Technology Data Exchange (ETDEWEB)

This paper reports thermal comfort and indoor air quality (IAQ) studies of an under-floor air-conditioning (UFAC) system in a hot and humid climate. Thermal comfort parameters were measured at pre-determined grid points within an imaginary plane to predict the air flow pattern of the supply air jet as well as to determine the occurrence of thermal stratification in the office space. Fanger's thermal comfort index was also computed to detect the occupants' thermal sensation. Besides, the concentration levels of dust and carbon dioxide were recorded with the intention to examine the quality of the indoor air. Statistical methods were applied to derive the relationship between air velocity and the other parameters as mentioned earlier. The main findings from the study revealed reasonable level of acceptability of IAQ associated with the UFAC system. However, occupants are likely to ...

2002-07-01

295

Marketers report on oil quality  

Energy Technology Data Exchange (ETDEWEB)

The quality of fuel oils is discussed. The problems that the fuel oil marketer must deal with that relate to the quality of the fuel oil are described.

1985-04-01

296

Effect of gasoline octane quality on vehicle acceleration performance  

Energy Technology Data Exchange (ETDEWEB)

A study was conducted under the auspices of the Coordinating Research Council, Inc. (CRC) to assess the potential effects of gasoline octane quality on vehicle acceleration performance. Twelve participating laboratories, representing both the oil and the automotive industries, tested a total of 182 vehicles as part of the 1989 CRC Octane Number Requirement Survey. The vehicles consisted of 78 with electronic knock control systems and 104 without. All testing was performed using the 1989/1990 CRC FBRU fuel series. The results showed that acceleration performance of vehicles with knock sensors was significantly affected by gasoline octane quality. Octane effects on acceleration performance were most pronounced at maximum-throttle (detent) conditions and at octane levels below the vehicles' octane requirements; however, some knock-sensor vehicles did show improved acceleration performance with fuels at octane levels ...

1991-07-01

297

Effect of Suburban Development and Landscape Position on Water Quality in Three Small Watersheds Within the Croton System, New York.  

Science.gov (United States)

Internal hydrological processes in suburban watersheds and their effects on water quality warrant investigation. Instrument clusters (throughfall collectors, suction lysimeters, monitoring wells, and shallow and deep piezometers) were installed at several locations within three small (50 - 70 ha) watersheds (one forested, two with different degrees of suburban development) in the Croton Watershed, southeastern New York. Biweekly and storm samples were analyzed for base cations, selected anions, and DOC over a one-year period. The topographic index (TI) quantified landscape position; flowpath analyses determined degree of development at each cluster, using % impervious cover as the metric. Water quality degradation was observed in sites with medium and high TI values; no such effect was observed along the ridges, i.e., low TI values. At medium TI values, areas with more than 5% impervious had degraded water quality. At high ...

2003-12-01

298

Assessment of the effects of pixel loss on image quality in direct digital radiography  

Energy Technology Data Exchange (ETDEWEB)

Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. ...

2004-03-21

299

Assessment of the effects of pixel loss on image quality in direct digital radiography  

International Nuclear Information System (INIS)

Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. Measurement of the MTF, NPS and DQE can ...

2004-03-21

300

Refrigerator operating experience on whole body MRI magnet systems  

International Nuclear Information System (INIS)

Several refrigerators for liquid helium and liquid nitrogen systems have been integrated successfully into IGC manufactured whole body Magnetic Resonance Imaging (MRI) magnet systems. The refrigerators have been tested in systems with magnetic fields of 0.6T to 1.5T. Tests were performed to study the effectiveness of the refrigerators, the magnetic field effects on the refrigerators, the effect of the refrigerators on the field uniformity and magnetic resonance image quality. The interface between the refrigerator and the whole body MRI magnet system cryostat was specifically designed to allow retrofit to the existing IGC magnet systems, while ensuring good heat transfer characteristics and good vibration isolation from the cryostat. The interface between the refrigerator and the cryostat and the refrigerator test results are presented.

1985-08-01

301

Development of the high sensitivity real-time neutron radiography for low-flux neutron sources  

Energy Technology Data Exchange (ETDEWEB)

The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose ...

1994-08-01

302

Development of the high sensitivity real-time neutron radiography for low-flux neutron sources  

International Nuclear Information System (INIS)

The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose ...

1994-01-01

304

Integrating decision support tools and environmental information systems: a case study on the Province of Milan  

International Nuclear Information System (INIS)

The paper demonstrates an application of advanced decision support tools within the framework of the environmental information system of the Province of Milan. These tools include environmental simulation models, multi criteria analysis, risk analysis and environmental accounting for marketable emission permits. After describing the general structure of the system, three demonstrational case studies are introduced concerning: groundwater pollution management; atmospheric pollution management; urban environmental quality perception and management. In the conclusion, potential use of tools like the ones implemented by the province of Milan within the framework of Local Agenda 21 processes is recalled.

2006-03-01

305

Heating-cooling ceilings and cold beams; Plafonds chauffants-rafraichissants et poutres froides  

Energy Technology Data Exchange (ETDEWEB)

The aim of this document is to make a state-of-the-art of the techniques of heating-cooling ceilings and cold beams. These systems offer many advantages: they generate a high quality thermal comfort, they are energy efficient, and offer important room saving, particularly interesting in the case of building renovation. The document comprises 5 parts dealing with: 1 - the heating-cooling ceilings; 2 - the cold beams; 3 - the elements necessary for the dimensioning (building-system interactions, ventilation, temperature regulation and safety systems); 4 - dimensioning method; 5 - design, realization and operation: the rules to follow. (J.S.)

2004-07-01

306

Anaerobic digestion of municipal solid waste: Technical developments  

Energy Technology Data Exchange (ETDEWEB)

The anaerobic biogasification of organic wastes generates two useful products: a medium-Btu fuel gas and a compost-quality organic residue. Although commercial-scale digestion systems are used to treat municipal sewage wastes, the disposal of solid organic wastes, including municipal solid wastes (MSW), requires a more cost-efficient process. Modern biogasification systems employ high-rate, high-solids fermentation methods to improve process efficiency and reduce capital costs. The design criteria and development stages are discussed. These systems are also compared with conventional low-solids fermentation technology.

1996-01-01

307

''SEPIO NUANCE DT'' digital mammography system  

International Nuclear Information System (INIS)

In the past, the need for high quality images, i.e., very sharp and clear images, in mammography have prevented mammography equipment from being digitalized; however, recent advances in detection technology such as development of a high resolution digital X-ray detector have produced improvements in digital mammography. Digital mammography is expected to replace conventional film-screen mammography. We have developed a digital mammography system, named ''SEPIO NUANCE DT'', which is equipped with a direct conversion flat panel detector. The present paper describes the high basic performance and user-friendly functions of the system. (author)

2007-03-01

308

Normalized noise power spectrum of full field digital mammography detector system  

International Nuclear Information System (INIS)

Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)

309

Normalized Noise Power Spectrum of Full Field Digital Mammography System  

International Nuclear Information System (INIS)

A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.

2010-01-05

310

Mental health in patients with systemic sclerosis: a controlled investigation  

British Library Electronic Table of Contents (United Kingdom)

Abstract Background Despite the undeniable impact of systemic sclerosis (SS) on quality of life, only a few studies so far have focused on its psychiatric or psychological aspects. We aimed at assessing psychiatric symptoms and self-image in inpatients with SS and comparing them with patients with either a very mild skin condition or a serious skin condition. Methods Three groups were recruited: (i) 38 consecutive female inpatients with SS; (ii) 38 age-matched female outpatients with melanocytic naevi; (iii) 35 age-matched female inpatients with melanoma. All participants completed the Zung Anxiety Scale, the Zung Depression Scale and a self-report questionnaire measuring self-perceived personal qualities. Patients with SS were also clinically interviewed by a psychologist. Results The cli...

2008-01-01

311

MOVPE growth of GaAs and InP based compounds in production reactors using TBAs and TBP  

Energy Technology Data Exchange (ETDEWEB)

Today TBP and TBAs are the compounds which have the highest potential to replace the hydrides arsine and phosphine in the MOVPE process. The authors have demonstrated the entire material system Ga-In-As-P can be grown without any loss of quality using TBP and TBAs not only in one reactor, but in a complete family of reactors. These reactors range from small-scale single wafer R and D reactors to multiwafer Planetary Reactor systems. Both InP based and GaAs based materials could be grown with an excellent quality. Thus all growth processes for III-V devices--long and short wavelength lasers, LEDs, high speed transistors, etc.--can be switched to TBP and TBAs. This will drastically reduce safety hazards and lead to processes that have advantages both from the ecological and economical point of view.

1996-12-31

312

Effect of convective wall currents on the air quality of source ventilation. Einfluss konvektiver Wandstroemungen auf die Luftqualitaet bei Quellueftung  

Energy Technology Data Exchange (ETDEWEB)

With the combination of source ventilation and ceiling cooling for air-conditioning of working and recreation rooms, a ventilation system is available which fulfills the highest demands regarding thermal comfort. In order to utilize the advantages of this ventilation system with regard to air quality and thermal comfort to an optimum, the influence of the radiation exchange between cooling ceiling and walls on the flow in the room is investigated experimentally. Energy transfer from the walls to the cooled ceiling may result in an insufficient temperature of the walls compared to ambient air and in an upward flow on the wall surfaces (downward flow of) driven by gravity, which influences the flow pattern in the case of source ventilation. (orig.)

1993-07-01

313

Dynamic construction of outage lists for safety analysis of power transmission lines. Dynamische Erstellung von Ausfallisten fuer die Sicherheitsanalyse elektrischer Energieuebertragungssysteme  

Energy Technology Data Exchange (ETDEWEB)

An adaptive contingency selection process is set up which produces outage lists in order to guarantee on-line network security control. The quality index system used so far did not detect and reveal all critical variables due to observation problems in the mapping of two functions. The new process uses the results of the outage simulation computing of the system status just past for the drawing up of an up-to-date outage list. A linear correcting function transform the G{sub 2}-values of the standard quality index method - which still incorporate the observation problem effect - into improved values G. Studies which use data from realstic high-voltage networks prove that the detection of critical variables is far superior to ordinary methods. (orig.).

1990-04-23

314

Continuous emission monitoring and quality assurance requirements for new power plants  

International Nuclear Information System (INIS)

Electric utility plants, for which construction commenced after September 18, 1978, must install and operate continuous emission monitoring (CEM) systems to demonstrate compliance with SO_2 and NO_x emission standards. Furthermore, effective December 4, 1987, each plant must develop and implement a CEM quality assurance (QA) program. This paper reviews the CEM and QA requirements set forth by new source performance standards (NSPS) promulgated by the Environmental Protection Agency. The paper summarizes operating characteristics of the 32 power plants currently subject to NSPS and describes the types of CEM systems used by these plants. Also, to the extent available, the paper presents the results of initial (i.e., first quarter 1988) QA activities (e.g., audits and calibration drift assessments) conducted by these plants.

1988-09-25

315

Re-Analysis of In-Service Inspection of Pressure Tubes and Feeder Pipes in Wolsong Unit 1  

Energy Technology Data Exchange (ETDEWEB)

Since the first commercial operation in 1983, Wolsung unit 1 has experienced several aging phenomena, especially in pressure tubes and feeder pipes. In case of pressure tubes, in-service inspections (ISI) revealed that a major portion of inspected tubes was in contact with calandria tubes. The likelihood of blister formation was a safety concern because it is a potential threat to pressure tube integrity. Wolsung unit 1 was, therefore, subjected to the SLAR (Spacer Location And Reposition) work to separate the contacted pressure tubes from calandria tubes. In this paper, experience of in-service inspection to the pressure tubes will be discussed including the irradiation creep elongation and CIGAR (Channel Inspection and Gauging Apparatus for Reactors) examination of pressure tubes. On the other hand, the problem of wall thinning in the feeder pipes became of great concern since 1996. ...

2005-07-01

316

Re-Analysis of In-Service Inspection of Pressure Tubes and Feeder Pipes in Wolsong Unit 1  

International Nuclear Information System (INIS)

Since the first commercial operation in 1983, Wolsung unit 1 has experienced several aging phenomena, especially in pressure tubes and feeder pipes. In case of pressure tubes, in-service inspections (ISI) revealed that a major portion of inspected tubes was in contact with calandria tubes. The likelihood of blister formation was a safety concern because it is a potential threat to pressure tube integrity. Wolsung unit 1 was, therefore, subjected to the SLAR (Spacer Location And Reposition) work to separate the contacted pressure tubes from calandria tubes. In this paper, experience of in-service inspection to the pressure tubes will be discussed including the irradiation creep elongation and CIGAR (Channel Inspection and Gauging Apparatus for Reactors) examination of pressure tubes. On the other hand, the problem of wall thinning in the feeder pipes became of great concern since 1996. ...

2005-10-27

317

High-accuracy gauge control technologies over the full length and full width of cold rolled strip; Reikan tandemumiru ni okeru zencho{center_dot}zenpuku hanko seigyo gijutsu  

Energy Technology Data Exchange (ETDEWEB)

At tandem cold rolling mills in Kawasaki Steel, by means of applying newly developed strip longitudinal (rolling) and transverse gauge control systems, high accuracy of thickness of within {+-}0.5 % has been achieved over the full length and full width of cold rolled strip, as gauge accuracy in a coil in longitudinal and transverse directions has become an extremely important quality control item in the manufacturing of cold rolled sheets due to the stricter quality requirements of customers, in recent years. The longitudinal gauge accuracy has been improved by the development of a high-response drive system for a mill mair motor, an all-stands gauge control system and a dynamic set-up control system. The transverse gauge accuracy has been improved by applying a one-side tapered work roll shifting method and the development of an edge drop control ...

1999-12-01

318

Harmonics in power systems of ships with electrical propulsion drives. Comparison between different converters  

Energy Technology Data Exchange (ETDEWEB)

In this report the effects of harmonics in marine power systems is discussed and a comparison is given between the most typical converter types, including pulse width modulated drives, load commutated inverters and cycloconverters. The effect of harmonic distortion on the power system equipment and loads is first briefly discussed. Special attention is given to the circumstances in the low voltage distribution system, where general load equipment is connected. In addition to the total harmonic distortion the effect of voltage deviation to the supply quality is also considered. The origin of harmonics in the load currents of the three converter types is then considered. The differences between the converters are outlined, and the most typical spectra are presented. The possible means for reducing the harmonic distortion are also studied. The solutions considered are the increasing of the short circuit ...

1996-11-01

319

Generalized simulation model for reservoir system analysis. Technical paper  

Energy Technology Data Exchange (ETDEWEB)

This paper overviews the general features of computer program 'HEC-5, Simulation of Flood Control and Conservation Systems', with emphasis on the capabilities of the most recent release of HEC-5, Version 7.2, dated March 1991. HEC-5 can simulate the essential features and operation goals and constraints of simple or complex systems with simulation intervals ranging from minutes to one month. Single event flood analysis and period of record conservation analysis may be accomplished with the model. Flood control analysis includes balanced system operation for downstream damage centers with consideration of forecasted local flows and hydrologic routing. In addition, induced surcharge operation based on spillway gate regulation schedules can be simulated. Hydropower analysis may include run-of-river, peaking, and pumped storage plants as well as system power operation. Water supply ...

1992-03-01

320

An experimental study of the ventilation performance of cold-air distribution systems  

Energy Technology Data Exchange (ETDEWEB)

The ventilation performance of cold-air distribution systems was investigated in a full-scale test room for three different designs of ceiling-mounted diffusers: a large square radial, a small square radial, and two linear diffusers. The supply air temperature was 38 F (3.3 C). Tests were conducted with internal heat loads and with and without furnishings. The local mean ages of air, air diffusion effectiveness, and contaminant-removal efficiency were measured using tracer gas techniques to assess the performance of the ventilation system in maintaining adequate air quality conditions in the occupied region. Air velocities and temperatures were also measured in the occupied region to calculate the air diffusion performance index (ADPI). It was found that the cold-air distribution system provided satisfactory air quality and thermal comfort conditions to the occupied region of the ...

1994-12-31

321

Investigation of corrosion experienced in a spray calciner/ceramic melter vitrification system  

Energy Technology Data Exchange (ETDEWEB)

After periodic testing of a large-scale spray calciner/ceramic melter vitrification system over a 2-yr period, sufficient corrosion was noted on various parts of the vitrification system to warrant its disassembly and inspection. A majority of the 316 SS sintered metal filters on the spray calciner were damaged by chemical corrosion and/or high temperature oxidation. Inconel-601 portions of the melter lid were attacked by chlorides and sulfates which volatilized from the molten glass. The refractory blocks, making up the walls of the melter, were attacked by the waste glass. This attack was occurring when operating temperatures were >1200/sup 0/C. The melter floor was protected by a sludge layer and showed no corrosion. Corrosion to the Inconel-690 electrodes was minimal, and no corrosion was noted in the offgas treatment system downstream of the sintered metal filters. It is believed that most of ...

1980-08-01

322

Development of a HVDC prototype breaker. Final report  

Energy Technology Data Exchange (ETDEWEB)

The significant design features of a high-voltage dc (HVDC) circuit breaker based on the commutation concept were developed. Tests of components indicate the breaker is capable of interrupting a fault current of 10 kA on a 400 kV system and absorbing up to 10 MJ of system energy without generating more than 1.6 per unit (P.U.) voltage of the system. Interactions of the breaker with a three-terminal network were studied, using a system simulator. An ultrafast hydraulic actuator system was developed for this program which enables the breaker to initiate the current limiting process within 5 ms after receipt of a trip signal. A new hydraulic valve, operated by a repulsion coil, minimizes the delay before motion begins. Interruption will occur in series-connected vacuum interrupters. A 400 kV circuit breaker is estimated to require eight breaks in series. Only a single break was tested ...

1980-06-01

323

State of the Art Laser Induced Breakdown Spectroscopy  

International Nuclear Information System (INIS)

Methods currently being used or developed for the elemental analysis of materials are chemical analysis, non-destructive inspection and calorimetry. The chemical analysis, which removes high-level radioactive elements through chemical treatments and then performs the quantitative analysis using the ICP-MS(Inductively Coupled Plasma - Mass Spectrometer) or the ID-MS(Isotope Dilution Mass Spectrometer), is recognized the most accurate. However, it requires a long, complex pre-treatment process in which a mass spectrometer could be contaminated. To solve this problem, a new method, which can be performed with high-level radioactivity and at high temperature, was desired. Such a method should also have the same accuracy as the chemical analysis, with a less possibility for instruments to be contaminated. In addition, as interests in the environment and the life quality are increased, a detailed analysis on the environmental impacts is also ...

324

Replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory  

Energy Technology Data Exchange (ETDEWEB)

The DOE-Idaho Operations Office (DOE-ID) has prepared an environmental assessment (EA) on the replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory at the Idaho National Engineering Laboratory (INEL). The purpose of this project is to replace the existing Health Physics Instrumentation Laboratory (HPIL) with a new facility to provide a safe environment for maintaining and calibrating radiation detection instruments used at the Idaho National Engineering Laboratory. The existing HPIL facility provides portable health physics monitoring instrumentation and direct reading dosimetry procurement, maintenance and calibration of radiation detection instruments, and research and development support-services to the INEL and others. However, the existing facility was not originally designed for laboratory activities and does not provide an adequate, safe environment for calibration activities. The EA examined the potential environmental impacts of the ...

1995-05-01

325

Implementation of integrated safeguards in Nuclear Fuel Plant at Pitesti, Romania  

International Nuclear Information System (INIS)

The nuclear activity was conducted for many years in Romania under Traditional Safeguards (TS) and has developed in good conditions the specific nuclear safeguards. Now there is a good opportunity to improve the performance and quality of the safeguards activity and at the same time to increase the accountancy and control of nuclear materials by passing to Integrated Safeguards (IS) implementation. The legal framework is the Law 100/2000 for ratification of the Protocol between Romania and International Atomic Energy Agency (IAEA), additional completion to the Agreement between the Socialist Republic of Romania Government and IAEA relating to safeguards. It is part of the Treaty on the non-proliferation of nuclear weapons published in the Official Gazette no. 3/31 January 1970, and the Additional Protocol published in the Official Gazette no. 295/ 29.06.2000. The first discussion about Integrated Safeguards (IS) between the Nuclear Fuel Plant (FCN) representatives ...

2009-10-12

326

Linac Coherent Light Source Longitudinal Feedback Model  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL). To ensure the vitality of FEL lasing, it is critical to preserve the high quality of the electron beam during acceleration and compression. The peak current and final energy are very sensitive to system jitter. To minimize this sensitivity, a longitudinal feedback system on the bunch length and energy is required, together with other diagnostics and feedback systems (e.g., on transverse phase space). Here, we describe a simulation framework, which includes a realistic jitter model for the LCLS accelerator system, the RF acceleration, structure wakefield, and second order optics. Simulation results show that to meet the tight requirements set by the FEL, such a longitudinal feedback system is mandatory.

2005-06-15

327

Assessment of periodic sub-diurnal Earth rotation variations at tidal frequencies through transformation of VLBI normal equation systems  

British Library Electronic Table of Contents (United Kingdom)

We present an empirical model for periodic variations of diurnal and sub-diurnal Earth rotation parameters (ERPs) that was derived based on the transformation of normal equation (NEQ) systems of Very Long Baseline Interferometry (VLBI) observing sessions. NEQ systems that contain highly resolved polar motion and UT1-TAI with a temporal resolution of 15?min were generated and then transformed to the coefficients of the tidal ERP model to be solved for. To investigate the quality of this model, comparisons with empirical models from the Global Positioning System (GPS), another VLBI model and the model adopted by the conventions of the International Earth Rotation and Reference Systems Service (IERS) were performed. The absolute coefficients of these models agree almost completely within 7.5?...

2011-01-01

328

Application of Risk Management for Control and Monitoring Systems  

CERN Document Server

This paper presents an application of the state of the art and new trends for risk management of safety-related control and monitoring systems, currently applied in the industry. These techniques not only enable to manage safety and reliability issues but they also help in the control of quality and economic factors affected by the availability and maintenance of the system. The method includes an unambiguous definition of the system in terms of functions and a systematic analysis of hazardous situations, undesired events and possible malfunctions. It also includes the identification and quantification of the risk associated to the system. The required risk reduction is specified in terms of safety integrity levels. The safety integrity level results in requirements, preventive measures, possible improvements and recommendations to assure the satisfactory management of the risk.

2001-01-01

329

Computed radiography (FCR) with a dual side reading system. Comparison with conventional radiography for visualization of nodular lung cancers  

International Nuclear Information System (INIS)

To assess the diagnostic capability Fuji computed radiography (FCR) using a dual side reading system was compared to the conventional radiography using a film-screen system. Twenty-eight patients with lung cancer were examined with a new FCR system (FCR 5501D) and a conventional screen-film system concurrently. FCR utilizes a reading system that detects emissions from dual sides of imaging plate. Chest X-rays were obtained with same exposure factors in both systems. Image qualities of both systems were compared by two radiologists using a five-level score. There were no lesion that FCR images were inferior to film-screen images. The frequency of score +1 or +2 that FCR images were superior to film-screen images was 31% in large nodular shadows, 40% in accompanying shadows with a nodule, 67% of small nodular shadows, and ...

2003-02-01

330

Standards for transport and storage components established by The Atomic Energy Society of Japan and The Japan Society of Mechanical Engineers  

Energy Technology Data Exchange (ETDEWEB)

Since June 1997 the standards/specifications and inspection/certification of various products in Japan have been reviewed by Ministries and Agencies, with the aim of reducing direct government intervention to a necessary minimum and creating a free and fair socio-economic system that is fully opened to the international community and based on the rules of self-responsibility and market principles. Reflecting this policy the administrative regulations which prescribe technical standards as specific requirements have been revised by degrees into performance prescriptions. Detailed provisions in ordinances and notices have been abolished gradually to utilize voluntary standards and rules. In the nuclear energy field voluntary standards are being developed to make up statutory performance requirements by the Atomic Energy Society of Japan (AESJ) and the Japan Society of Mechanical Engineers (JSME) together with other organizations such as the Japan ...

2004-07-01

331

Seal Monitoring System for an Explosive Containment Vessel  

Energy Technology Data Exchange (ETDEWEB)

Researchers at Lawrence Livermore National Laboratory are developing high-performance explosive firing vessels to contain (one time) explosive detonations that contain toxic metals and hazardous gases. The filament-wound polymer composite vessels are designed to contain up to 80 lb (TNT equivalent) explosive in a 2-meter sphere without leakage. So far, two half-scale (1-meter diameter) vessels have been tested; one up to 150% of the design explosive limit. Peak dynamic pressures in excess of 280 MPa (40 Ksi) in the vessel were calculated and measured. Results indicated that there was a small amount of gas and particle leakage past the first two of the seven o-ring seals. However, the remaining five seals prevented any transient leakage of the toxic gases and particulates out of the vessel. These results were later confirmed by visual inspection and particulate analysis of swipes taken from the sealing surfaces.

2004-06-28

332

Measures for reliability improvement of on-site power plant at steel works  

Energy Technology Data Exchange (ETDEWEB)

This report describes the arrangement and features of the Ogishima thermal power plant facilities, as well as activities being performed there for operation control, regular inspection and improvement in reliability. The power plant uses about 48 percent of the by-product gas as its fuel to supply about 81 percent of the required power. Operation of the No. 1 unit started in 1976. Currently, the plant has three units, each with an output of 125MW. Each unit consists of a natural circulation boiler with a maximum evaporation capacity of 410 ton/hour and a reheat regenerative condensing turbine with a main vapor pressure of 127 kg/cm/sup 2/G. Techniques used for water properties control and combustion control are also described. In the plant, convetional time management integrity techniques are now being replaced by state management integrity techniques that determines the deterioration tendency in separate sections of the facilities which are divided in ...

1988-04-15

333

High Velocity Molecular Outflows In Massive Cluster Forming Region G10.6-0.4  

CERN Document Server

We report the arcsecond resolution SMA observations of the $^{12}$CO (2-1) transition in the massive cluster forming region G10.6-0.4. In these observations, the high velocity $^{12}$CO emission is resolved into individual outflow systems, which have a typical size scale of a few arcseconds. These molecular outflows are energetic, and are interacting with the ambient molecular gas. By inspecting the shock signatures traced by CH$_{3}$OH, SiO, and HCN emissions, we suggest that abundant star formation activities are distributed over the entire 0.5 pc scale dense molecular envelope. The star formation efficiency over one global free-fall timescale (of the 0.5 pc molecular envelope, $\\sim$10$^{5}$ years) is about a few percent. The total energy feedback of these high velocity outflows is higher than 10$^{47}$ erg, which is comparable to the total kinetic energy in the rotational motion of the dense molecular envelope. From order-of-magnitude ...

2010-01-01

334

Consequences of power peak production on sediments in tunnels and surge shafts. Partial report Phase 1: Field investigations; Konsekvenser av effektkjoering paa sedimentforhold i tunneler og svingesjakter. Delrapport fase 1: Feltundersoekelser  

Energy Technology Data Exchange (ETDEWEB)

In July 1997, a field inspection was carried out of parts of the tunnel system of the Tonstad hydroelectric power station, Norway. This report discusses the findings: (1) The main drift has a varying bottom covering of sediments, (2) The tunnel to Ousdal had on its downmost 2 km an almost unbroken and apparently stable armour layer along the walls and an unstable or incomplete armour layer in the middle, (3) The tunnel to Homstoel almost had no bottom layer, (3) Sediments in side inlets and niches are of two kinds: (a) masses added through side inlets, (b) fine sand and mud deposited by the main tunnel, (4) A few cases were observed of downfallen rocks and of peeled rock of about 1 m size. It looks as if the Homstoel tunnel may have been previously used for larger discharges than that from Ousdal and that the latter is now being used to the limit of what the previously established armour layer can stand

1997-10-01

335

CFD Application to the Regulatory Assessment of FAC-Caused CANDU Feeder Pipe Wall Thinning Issue  

Energy Technology Data Exchange (ETDEWEB)

From the results of the In-Service Inspection (ISI) measuring the wall thickness of outlet (hot-leg side) feeder pipes performed at two Canadian nuclear power plants, Point Lepreau and Gentilly-2 in 1995 and 1996, respectively, the wall thinning degradation of feeder pipes at the bend part was found to be much more severe than expected. It has been well known that such wall thinning of feeder pipes is caused by the flow accelerated corrosion (FAC) which is one of the mechanical-chemical degradation mechanisms affecting the integrity of piping systems. For the Wolsung unit 1, the wall thickness measurements have been performed during every overhaul period since 1996. The wall thinning rates at the bends of outlet feeder pipes were assessed to exceed the design value. However, for the Wolsung units 2, 3 and 4, the wall thinning rates of all the outlet feeder pipes were assessed not to exceed it. The reason is because the content of Cr in the ...

2007-07-01

336

CFD Application to the Regulatory Assessment of FAC-Caused CANDU Feeder Pipe Wall Thinning Issue  

International Nuclear Information System (INIS)

From the results of the In-Service Inspection (ISI) measuring the wall thickness of outlet (hot-leg side) feeder pipes performed at two Canadian nuclear power plants, Point Lepreau and Gentilly-2 in 1995 and 1996, respectively, the wall thinning degradation of feeder pipes at the bend part was found to be much more severe than expected. It has been well known that such wall thinning of feeder pipes is caused by the flow accelerated corrosion (FAC) which is one of the mechanical-chemical degradation mechanisms affecting the integrity of piping systems. For the Wolsung unit 1, the wall thickness measurements have been performed during every overhaul period since 1996. The wall thinning rates at the bends of outlet feeder pipes were assessed to exceed the design value. However, for the Wolsung units 2, 3 and 4, the wall thinning rates of all the outlet feeder pipes were assessed not to exceed it. The reason is because the content of Cr in the ...

2007-05-10

337

Boat sampling technique for assessment of ageing of components  

International Nuclear Information System (INIS)

Boat sampling technique (BST) is a surface sampling technique, which has been developed for obtaining, in-situ, metal samples from the surface of an operating component without affecting its operating service life. The BST is non-destructive in nature and the sample is obtained without plastic deformation or without thermal degradation of the parent material. The shape and size of the sample depends upon the shape of the cutter and the surface geometry of the parent material. Miniature test specimens are generated from the sample and the specimens are subjected to various tests, viz. Metallurgical Evaluation, Metallographic Evaluation, Micro-hardness Evaluation, sensitisation test, small punch test etc. to confirm the integrity and assessment of safe operating life of the component. This paper highlights design objective of boat sampling technique, description of sampling module, sampling cutter and its performance evaluation, cutting process, boat samples, operational sequence of ...

2006-11-01

338

The role of the United States Food Safety and Inspection Service after the Chernobyl accident  

International Nuclear Information System (INIS)

The Food Safety and Inspection Service (FSIS) of the United States Department of Agriculture (USDA) inspects domestic and imported meat and poultry food products to assure the public that they are safe, wholesome, not economically adulterated and properly labeled. The Service also monitors the activities of meat and poultry plants and related activities in allied industries, and establishes standards and approves labels for meat and poultry products. As part of its responsibility, shortly after the Chernobyl accident occurred, FSIS developed a plan to assess this accident's impact on domestically produced and imported meat and poultry

1989-09-01

339

Implementation and management of Daya Bay Nuclear Power Plant in-core flux thimble tube in-service inspection  

International Nuclear Information System (INIS)

This article discusses the Daya Bay nuclear power plant in-core flux thimble tube in-service inspection method and strategy. High light of the multiple frequency eddy current technology adopted including frequency and probe choice, standard design, data acquisition process are involved. The wear defect-growing trends are studied on base of the history data, which contribute to the in-service inspection strategy decision. (authors)

2003-04-08

340

High Resolution Eddy Current Probes for Non Destructive Testing  

Science.gov (United States)

New industrial Non Destructive Testing requires the development of new probes: technologies such as high spatial resolution probes for small breaking flaws detection or flexible probes for complex curved surfaces inspection. The CEA/LIST has designed and integrated 2 probes to answer industrial's constraints. The first one is based on Giant Magneto-Resistance and is able to detect 50 ?m3 flaws. The second one is based on micro-coils etched on kapton and its flexibility is adapted to curved surfaces inspection. Both are multi-elements probes, allowing fast inspection. This paper presents those new probes, their design and their performances.

2008-02-01

341

Finite element calculations for eddy current interactions with collinear slots  

Energy Technology Data Exchange (ETDEWEB)

The results of finite element calculations detailing the interactions of eddy currents with fine collinear slots in nonferromagnetic and ferromagnetic conductors are presented. These are applicable to both remote field eddy current inspection tools and conventional reflected impedance eddy current probes. The calculations show that, while fine slots have little interaction with collinear induced currents in nonferromagnetic conductors, there are much larger effects in ferromagnetic conductors. This is due to magnetic field interactions. The term eddy current inspection' is therefore somewhat restrictive and the much broader term electromagnetic inspection' is proposed.

1994-01-01

342

The utilization of non-destructive method for in-service inspections in nuclear power components  

International Nuclear Information System (INIS)

To ensure safe and reliable power production nuclear power plants must be operated at high level. Non destructive in-service inspections are inseparable part of the effort. Non destructive in-service inspections are essential on the ground of degradation mechanisms existence in nuclear power components. Degradation processes are constituent of operation of each industrial installation including nuclear power plants. Mission of non-destructive testing is degradation detection, closer characterization of its parameters (dimensions) and to supply as much information as possible to nuclear power plant operator. Eddy current testing method can be assigned to surface - volumetric methods. Method enables inspection of electrically conductive materials. It is particularly suitable for inspection of non-ferromagnetic materials like austenitic stainless steel and brass. The method is used for detection of stress ...

2006-01-01

343

National Response Center Intro Page  

Science.gov (United States)

operations and defense, personnel misconduct (PM), law enforcement (LE), and counterintelligence (CI) investigations.- At any time, the USG may inspect and seize data stored on...

2011-02-28

344

Foveal Machine Vision for Mobile Robots using Agent Based Gaze  

Science.gov (United States)

... non- emissive guidance and collision alert, automated transport in dynamic environments, and assembly and inspection. Foveal Vision, Autonomous Agents, ...

345

Cartridge Cases.  

Science.gov (United States)

This report provides procedures for evaluating metal, consumable, and combustible cartridge cases. It identifies supporting tests, facilities, and equipment required. Subtests include weapon and ammunition preparation, initial inspection, ammunition chara...

1980-01-01

346

Arms Control Verification Is No Longer a Stumbling Block to ...  

Science.gov (United States)

... irispectors to operate or Soviet territory. They exr-essed this reluctarice ir interniat ionai law terms, claimirig that inspect ior act ivit ies ...

1992-05-01

347

Use of BWR/6 PRA to assess the effect of proposed new QA requirements  

International Nuclear Information System (INIS)

The probabilistic risk assessment (PRA) of the General Electric BWR/6 Mark III standard plant has been used to assess the effect of proposed new quality assurance requirements on the off-site plant risk. This work was performed by General Electric Company under contract to the Electric Power Research Institute. First, the potential changes in the reliability of structures, systems and components were estimated. Then those changes that could affect the event tree and fault tree results were identified. Finally these changes were propagated through the probabilistic risk assessment fault trees and event trees to determine the effect upon off-site plant risk. The results show that applying quality assurance requirements, very nearly equal to those of 10CFR50, Appendix B (3), to nearly all nonsafety-related structures, systems, and components would have a negligible effect on off-site plant risk. In this ...

1985-02-01

348

The building tomorrow and after..; Le batiment demain et apres-demain..  

Energy Technology Data Exchange (ETDEWEB)

During its jubilee, the French building technical and scientific centre (CSTB) has organized a colloquium about the future tendencies of buildings evolution in the 20 forthcoming years: autonomy in energy production and wastes or effluents management, reduction of water consumption and management of water, hot water production and space heating, bio-sensors for the management of indoor air-quality, control of noise environment using active acoustic systems etc.. (J.S.)

1998-01-01

349

Program Status | Environmental Information Exchange Network & Grant Program | US EPA  

Wastenet

... Reduce partner costs, save time, and overcome delays in data transmission. Data Exchanges States are currently submitting data to each other and to the EPA in the exchanges listed below. Data Exchanges are typically referred to by their acronyms, which are listed below. To find out more about EPA data exchanges, please follow the links to EPA Web sites. AQS - Air Quality Sub-system (...

350

Pipe behaviour in bottom ash slurry systems  

Energy Technology Data Exchange (ETDEWEB)

This study presents the results of an 18-year long investigation of pipe deterioration in cyclone slag slurry transport. The goal was to study pipe behaviour in this extremely abrasive service and select an optimum piping material. Comparisons are given for high quality alloy cast steel pipes and pipes alined with cast basalt rings marketed under the name Abresist.

1982-09-01

351

Pipe behaviour in bottom ash slurry systems  

Energy Technology Data Exchange (ETDEWEB)

This study presents the results of an 18-year long investigation of pipe deterioration in cyclone slag slurry transport. The goal was to study pipe behaviour in this extremely abrasive service and select an optimum piping material. Comparisons are given for high quality alloy cast steel pipes and pipes lined with cast basalt rings marketed under the name Abresist. Based on the results, thoughts are offered on the broader meanings of certain findings.

1982-09-01

352

New standard environmental management  

International Nuclear Information System (INIS)

The ISO 14001:2004 standard, like ISO 9001:2000 on quality management, transcends the preventive approach (based on a rigid and more or less adequate process-management model still mainly inspired by traditional production methods) and introduces in its stead a highly flexible approach applicable to any socio-economic activity. It is structured by processes rather than system elements, and is based on the quest for efficacy and ongoing improvement.

353

Green design focus: Energy efficiency and environmental responsibility  

Energy Technology Data Exchange (ETDEWEB)

This case study illustrates how an existing building can be transformed into a sustainable, green facility through teamwork. This multi-purpose building comprises office space, combustion testing facilities, and microwave communications center. The paper discusses internal systems design, indoor air quality, commissioning, economics, operations and maintenance, and monitoring.

1998-02-01

354

Environmental and thermal efficiency benefits by use of RDF  

International Nuclear Information System (INIS)

This paper presents a brief overview of refuse derived fuel (RDF) processing systems, and the different types of RDF. The quality of RDF, combustion of RDF in fluidized beds, and moving grate reactors, operating conditions, emissions (sulphur dioxide, nitrogen oxides, carbon monoxide and hydrogen chloride) and thermal efficiency are discussed. (UK).

1994-05-01

355

Combined-cycle cogen plant a successful good neighbor  

Energy Technology Data Exchange (ETDEWEB)

This article describes a new natural-gas-fired combined cycle cogeneration plant in Bellingham, Washington. The topics of the article include community impact, siting constraints, natural gas fuel, the flexibility provided by the steam turbine, the cooling tower and pumps, air-quality, noise, and cooling water system constraints, and community relations program.

1993-04-01

356

Sensors and instrumentation for atmospheric pollutions control; Capteurs et instrumentation pour le controle des pollutions atmospheriques  

Energy Technology Data Exchange (ETDEWEB)

Reinforcement of the legislation concerning the emission of atmospheric pollutants, aerosols, refrigerants, solvents etc and the reduction of the greenhouse effect, has led to the development of performing instruments for the survey and control of ambient air quality and for the limitation of exhaust gases, combustion products, volatile organic compounds (VOC), particulates and noxious compounds in the atmosphere. This study is divided in 4 main parts. The first part describes the context of the air quality control: the problems linked with the environment and health, the pollutants characteristics, the pollution levels and the detection sensitivity of instruments according to the different type of pollutants (petroleum products, VOCs, ozone compounds, particulates, smells..), the protocols of air pollution measurements and their application (chimney smokes, industrial volatile compounds, indoor and ambient air quality, ...

1996-11-01

357

Large-scale production of single-walled carbon nanotubes by induction thermal plasma  

International Nuclear Information System (INIS)

High quality single-walled carbon nanotubes (SWNT) have been synthesized at large scales by the method of direct evaporation of carbon black and metallic catalyst mixtures, using induction thermal plasma technology. The processing system consists mainly of an RF plasma torch, which generates a plasma jet of extremely high temperature (?15 000 K), with a high energy density and abundance of reactive species (ions and neutrals). With the present reactor system, it has been demonstrated that carbon soot product which contains approximately 40 wt% of SWNT can be continuously synthesized at the high production rate of ?100 g h-1. The processing parameters involved have been examined closely in order to evaluate their individual influences on SWNT synthesis. The results have shown that the quality and purity of the SWNT produced are critically affected by the grade of carbon black, the plasma gas composition ...

2007-04-21

358

Implant detectibility of intervertebral disc spacers in post fusion MRI: evaluation of the MRI scan quality by using a scoring system - an in vitro study  

International Nuclear Information System (INIS)

Intervertebral spacers for anterior spine fusion are made of different materials, such as titanium and cobalt chromium alloys and carbon fiber-reinforced polymers. Implant-related susceptibility artifacts can decrease the quality of MRI scans. The aim of this cadaveric study was to demonstrate the extent that implant-related MRI artifacting affects the postfusion differentiation of determined regions of interest (ROIs). In six cadaveric porcine spines, we evaluated the postimplantation MRI scans of a titanium, cobalt-chromium and carbon spacer that differed in shape and surface qualities. A spacer made of human cortical bone was used as a control. A defined evaluation unit was divided into ROIs to characterize the spinal canal as well as the intervertebral disc space. Considering 15 different MRI sequences read independently by an interobserver-validated team of specialists the artifact-affected image quality of the median ...

2007-02-01

359

Numerical analysis of a natural convection cooling system for radioactive canisters storage  

International Nuclear Information System (INIS)

This paper describes the use of numerical analysis for studying natural convection cooling systems for long term storage of heat producing radioactive materials, including special nuclear materials and nuclear waste. The paper explains the major design philosophy, and shares the experiences of numerical modeling. The strategy of storing radioactive material is to immobilize nuclear high-level waste by a vitrification process, convertion it into borosilicate glass, and cast the glass into stainless steel canisters. These canisters are seal welded, decontaminated, inspected, and temporarily stored in an underground vault until they can be sent to a geologic repository for permanent storage. These canisters generate heat by nuclear decay of radioactive isotopes. The function of the storage facility ventilation system is to ensure that the glass centerline temperature does not exceed the glass transition temperature during ...

1995-02-01

360

Joint Thesaurus. Part I (A-L) + Part II (M-Z)  

International Nuclear Information System (INIS)

This is the 1st revision of the INIS/ETDE Joint Thesaurus. It contains 20 953 valid descriptors and 8 600 forbidden terms. It was last updated in December 2003. The Joint Thesaurus contains the controlled terminology for indexing all information within the subject scope of both INIS (International Nuclear Information System) and ETDE (Energy Technology Data Exchange) information systems. The terminology is intended for use in subject description for input or retrieval of information in those systems. The thesaurus is a terminological control device used in translating from the natural language of documents, indexers or users into a more constrained system language It is also a controlled and dynamic vocabulary of semantically and generically related terms which covers a specific domain of knowledge. The domain of knowledge covered by this Thesaurus includes physics (in particular, plasma physics, atomic ...

1998-05-01

361

Development of a neutron imaging facility at the CENM Al Maamora TRIGA  

Energy Technology Data Exchange (ETDEWEB)

The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of the tangential channel is around 3.10{sup 11} n*cm{sup 2}/s. This facility will be based on a conical neutron collimator with two circular ...

2009-07-01

362

Development of a neutron imaging facility at the CENM Al Maamora TRIGA  

International Nuclear Information System (INIS)

The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of the tangential channel is around 3.1011 n*cm2/s. This facility will be based on a conical neutron collimator with two circular diaphragms with ...

2009-06-07

363

Soil less culture; I sistemi di coltivazione senza suolo  

Energy Technology Data Exchange (ETDEWEB)

The paper gives a general view of techniques and systems related to soil less culture developed in the last years (on substrate in beg; NFT; Ebb-Flood, aeroponic,..) taking into account their management and problems (water quality, control of plant nutrition and irrigation; substrates; pathological aspects,..). The evolution, now in progress, of soil less culture from open to closed system as a way to realized an environmental friendly growing system, is considered. When plants are grown with open cycle techniques a large amount of waste solution, with an a high content of nutrients, are discharged in soil and water. Furthermore, they need an extra-utilization of water and fertilizers. Another aspect is the utilization of low cost substrates, which can be reused for more than one cultural cycle without negative effects on yield, and also finally discharged without negative effects on the environment. ...

1996-01-01

364

Rational protection of the quality of coastal waters by means of integrated, real-time management of the water environment; Proteccion racional de la calidad de las aguas costeras mediante la gestion integrada y en tiempo real del medio hidrico  

Energy Technology Data Exchange (ETDEWEB)

Before the implementation Water Framework directive, it was usual to forget that a good environment protection of the receiving waters needs a correct and coordinated operation of the subsystems of the water cycle, specially sewerage system, WWTP and receiving waters. This explains that most of the countries have focused their efforts in the treatment of dry weather flows forgetting the management of wet weather flows. Actually the idea that a sewerage system or a WWTP can not be planned or managed independently without considering the effects on the receiving waters is commonly accepted because not only each one of these systems must work correctly but also it is required a minimum impact in the receiving waters of the sewerage and WWTP overflows in dry and wet weather. All these links will affect the management strategy of the sewerage system (storm water detection tanks, gates, pumping stations, ...

2005-07-01

365

Latest trends in rolling mill facilities toward the 21st century; 21 seiki ni muketa saishin atsuen setsubi no doko  

Energy Technology Data Exchange (ETDEWEB)

Described herein are the latest trends in rolling mill facilities toward the 21st. century and new techniques developed by Hitachi Ltd. These cover hot rolling facilities, such as two-stage twin, high crown control-roll cross mill, roll shaping machine and continuous hot rolling systems; cold rolling facilities, such as pickling line-tandem cold mill and other continuous systems; and fine steel rolling facilities, such as roll mill for very small diameter pipes and others to improve productivity and product quality. The other new techniques include systems to pursue reliability and maintainability, in which electric appliances, instruments and computers are integrated, or equipped with built-in large-capacity inverters and drivers. For hot rolling, the above techniques lead to development of a new system named Hi-HOT, which produces high-quality hot coils at a ...

1996-06-01

366

Ventilation on demand: The efficient way to ensure clean air; Bedarfsgeregelte Lueftung: Dicke Luft wirtschaftlich verhindern  

Energy Technology Data Exchange (ETDEWEB)

Ventilation systems must ensure high room air quality with minimum energy consumption in all states of operation. Systems for ventilation on demand are increasing their market share. (orig./MSK) [Deutsch] Oberste Aufgabe von Raumlufttechnischen Anlagen ist die Sicherstellung guter Raumluftqualitaet bei minimalem Energieverbrauch unter allen Betriebsbedingungen. Um dieses Ziel zu erreichen, setzt sich am Markt zunehmend die bedarfsgeregelte Lueftung durch. (orig./MSK)

1997-11-01

367

Renovation of air-conditioning at La Defense; Renovation de la climatisation a La Defense  

Energy Technology Data Exchange (ETDEWEB)

Twenty years after its building, the tertiary sector of La Defense district near Paris has been rehabilitated. The main reason is not only the age and wear of materials but the heating costs, the fire protection regulations, the search for a better air quality and air renewing with less dusts, smells and noise and a controlled moisture. This paper describes first the original installation of the Monge CB 6 office building and then the renovated installation: the central hot and cold air-treatment plant, the variable flow ventilation system, the air extraction and supply system threw the roofs and the pressure and thermal regulation of the installation. (J.S.)

1997-05-01

368

Renewable energy systems for rural areas  

International Nuclear Information System (INIS)

In the rural areas, especially those located far enough from infrastructure facilities (highways and national roads, electricity and gas networks, etc.), energy supply (both quantitatively and qualitatively) is scarcer than in the urban ones. The purpose of this paper is to analyse the use of renewable energy hybrid systems in order to increase the quality and the quantity of energy supplied to the rural settlements. The paper is thus a guide of how to choose the appropriate energy source with higher potential and efficiency, minimal capital and operational costs and better comfort. (authors)

2007-11-22

369

Performance Testing Methodology for Safety-Critical Programmable Logic Controller  

International Nuclear Information System (INIS)

The Programmable Logic Controller (PLC) for use in Nuclear Power Plant safety-related applications is being developed and tested first time in Korea. This safety-related PLC is being developed with requirements of regulatory guideline and industry standards for safety system. To test that the quality of the developed PLC is sufficient to be used in safety critical system, document review and various product testings were performed over the development documents for S/W, H/W, and V/V. This paper provides the performance testing methodology and its effectiveness for PLC platform conducted by KOPEC

2009-05-01

370

Nippon Kokan technical report, No. 108, July 1985  

Energy Technology Data Exchange (ETDEWEB)

Contents include: countermeasures to save energy of sintering plant and future plans in fukuyama works; improvement of surface quality of continuous-casting slab; development of direct quenching and tempering type HT80 steel with good weldability; numerical analysis of fluid flow in a geothermal reservoir; the finite-element calculation of turbulent flow using the universal law of the wall; development of PC 4 dual fuel engine; design of industrialized housing; Computer-aided Navigation system (CANSY); and new production control system in Fukuyama Works.

1985-01-01

371

Low Temperature Systems (LTS); LTS (Lage Temperatuur Systemen)  

Energy Technology Data Exchange (ETDEWEB)

Several aspects of low temperature systems (LTS) are discussed in five articles. In the first article the role of municipalities in the Netherlands in the implementation of LTS is outlined. In the second article a brief overview is given of a brochure in which 9 projects with LTS are described. In article three the results of a literature study on qualitative aspects (thermal comfort, air quality, energy consumption, safety and cost) of LTS are presented. In the fourth article it is outlined why one should apply LTS, and the fifth article is a reflection of the discussion that took place at the TVVL symposium on sustainable concepts and sustainable installation

1999-04-01

372

DKV conference Vol. 26 (1999). No. 4. Session 4; DKV-Tagungsbericht. 26. Jahrgang (1999). Bd. 4. Arbeitsabteilung 4  

Energy Technology Data Exchange (ETDEWEB)

Vol. 4 comprises 23 papers on the following subjects: General aspects (effects in the human/environment systeme); Trends in space HVAC engineering; Heating systems engineering; Air quality and thermal comfort. [German] Der Tagungsband 4 enthaelt 23 Aufsaetze. Sie sind in die folgenden vier Themen-Bloecke aufgeteilt: Allgemeines (Wirkungen in der wahrgenommenen Wirkungssystem: Mensch-Umwelt); Entwicklungen in der Raumlufttechnik; Heizungstechnik; Luftqualitaet und Behaglichkeit. (AKF)

2000-07-01

373

Triacontanol-mediated regulation of growth and other physiological attributes, active constituents and yield of Mentha arvensis L.  

British Library Electronic Table of Contents (United Kingdom)

Triacontanol (TRIA) has been realized as a potent plant growth promoting substance for a number of agricultural and horticultural crops. Out of a large number of essential oil bearing plants, mint (Mentha arvensis L.) constitutes the most important source of therapeutic agents used in the alternative systems of medicine. The mint plant has marvelous medicinal properties. In view of enhancing growth, yield and quality of this medicinally important plant, a pot experiment was conducted according to simple randomized block design. The experiment was aimed at studying the effect of four concentrations of TRIA (10?0, 10?7, 10?6 and 10?5?M) on the performance of mint with regard to growth and other physiological attributes, crop yield and quality attributes and the yield and contents of active c...

2011-01-01

374

The work of the CONRAD task group 5.2: research studies on biokinetic models.  

Science.gov (United States)

The objective of this Task Group is the coordination of research studies on biokinetic models and the evaluation of the implications of new biokinetic models on dose assessment and safety standards. For this the new ICRP models, which will be used for a revision of ICRP Publications 30, 54, 68 and 78, are implemented into six different computer codes in five European countries and quality assured by intercomparison procedures. The work has started with the implementation of the new ICRP Alimentary Tract Model. New systemic models and the new NCRP wound model will follow. The work also includes the evaluation of experimental results in terms of formulation by the new model structures and a quality assurance of model formulation. PMID:17556343

2007-06-07

375

Studies on the appearance of skeletal anomalies in red porgy: effect of culture intensiveness, feeding habits and nutritional quality of live preys  

British Library Electronic Table of Contents (United Kingdom)

Summary Despite the great interest of red porgy as a new species for Mediterranean aquaculture, its commercial production is constrained by the high incidence of skeletal deformities occurring in this species under culture conditions. Several studies have been conducted to better understand the origin of these anomalies in this species, using different system intensiveness, rotifers enrichment products or rotifers docosahexaenoic acid content. The first study showed that culture intensification increased the number of fish with an extra vertebrae, what was probably related to the different nutritional quality of live preys employed in each treatment, since water temperature, salinity and genetic background were identical for the different batches of fish studied. Total incidence of skeleta...

2010-01-01

376

Searching for immunomodulatory sequences in sea bass (Dicentrarchus labrax L.): Transcripts analysis from thymus  

British Library Electronic Table of Contents (United Kingdom)

The thymus is a key organ of the immune system in most vertebrates and, for this reason, it has been used in this paper for the generation of a normalized cDNA library from sea bass (Dicentrarchus labrax), one of the most extensively cultured species in South Mediterranean aquaculture. A total of 1632 ESTs from this library were initially analysed for sequence quality and vector sequences and, after this control, 1264 (77% of total clones sequenced) high-quality ESTs were further processed. The total collection of D. labrax thymus ESTs has been deposited in the EBI-GenBank-DBJ database (GenBank accession numbers from FN565576 to FN566839). The functional classification of ESTs was performed by Gene Ontology and KEGG annotation and, successively, the sequences were analysed using the Immuno...

2010-01-01

377

Repetitive model refactoring strategy for the design space exploration of intensive signal processing applications  

British Library Electronic Table of Contents (United Kingdom)

The efficient design of computation intensive multidimensional signal processing applications requires dealing with three kinds of constraints: those implied by the data dependencies, the non-functional requirements (real-time, power consumption) and resources availability of the execution platform. Modeling and Analysis of Real-time and Embedded systems (MARTE) UML profile through its repetitive structure modeling (RSM) package is well suited to model the inherent parallelism within these applications, a compact representation of parallel execution platforms and the distributive mapping of one on another. The execution of such a specification respects the whole set of constraints defined upon, while the quality of the scheduling is directly linked to the quality of the mapping of the mult...

2011-01-01

378

Improvement of lake water quality by paying farmers to abate nonpoint source pollution. Research report  

Energy Technology Data Exchange (ETDEWEB)

To mitigate damages caused by agricultural runoff, private lake owners' associations are paying for inlake and instream pollution abatement measures and on land-conservation practices. This phenomenon supports the notion that individuals who benefit from improved water quality should be willing to pay part of the abatement costs. The research suggests that on land-conservation measures can substantially reduce sediment delivery at low cost. The Sediment Economics (SEDEC) model was modified and then used to select and to site management systems that achieved stated sediment goals at least cost. Other resource policies such as T value, no-till, and contouring were compared with the least-cost frontier and shown to be more costly. The noncropland areas substantially reduced sediment delivery to water channels and lowered abatement costs. Further research is needed for long-range watershed-planning models such as SEDEC.

1988-12-01

379

Combined inverse modeling approach and load duration curve method for variable nitrogen total maximum daily load development in an agricultural watershed  

British Library Electronic Table of Contents (United Kingdom)

Purpose Nonpoint sources (NPS) pollution has been an important cause for water quality impairment worldwide. To take the temporal variations of both NPS pollution and in-stream attenuation into consideration, an inverse modeling approach and the load duration curve (LDC) method were combined for variable nutrient total maximum daily load (TMDL) development. Methods Water quality and hydrological parameters were monitored monthly along the ChangLe River system in 2004?2008. The catchment NPS export load (EL) and TMDL for total nitrogen (TN) were estimated by the inverse format of an existing stream nutrient transport equation. The LDC method was used to describe the variability of EL, TMDL, requiring load (RLR) and percent (the ratio between the RLR and the EL, RPR) reduction, and then to s...

2011-01-01

380

Care programmes and integrated care pathways  

British Library Electronic Table of Contents (United Kingdom)

Purpose - The article discusses how care programmes and integrated care pathways can be linked, finding ways to improve healthcare process professional and logistical quality from a supply chain and a network point-of-view. Design/methodology/approach - The authors argue that owing to cost containment goals and increasing healthcare demand, healthcare services systems are challenged to improve service quality, whilst at the same time finding ways to improve delivery processes. It explores if the combination of two instruments, care programmes and integrated care pathways, can meet both goals. This combination is illustrated by an example from the Institute of Mental Health Care Eindhoven en de Kempen. Findings - Analysis suggests that care programmes can be combined with integrated care pa...

2008-01-01

381

Atmospheric pollution 1980. Proceedings of the fourteenth international colloquium, Paris, France, May 5-8, 1980  

Energy Technology Data Exchange (ETDEWEB)

Papers are presented on the modeling, dispersion, formation, transformation, monitoring and biological effects of atmospheric pollution. Specific topics include a prognostic mesoscale model for pollutant transport and diffusion, commuter exposure modeling, a Gaussian plume model for an urban area, carbon monoxide dispersion in an urbanized area, wind-tunnel modeling of flue gas dispersion, the regional-scale transport of fine aerosol components in eastern North America, and a Markov process for the generation of hourly average wind vectors. Attention is also given to photochemical aerosol formation in multicomponent systems, heterogeneous nitrogen oxide-particulate reactions, the generation and measurement of primary soot aerosols of size between 50 and 400 A, inertial particle size classification techniques, the design of air quality monitoring networks, visibilities in polluted and unpolluted areas, and monitoring air ...

1980-01-01

382

Assurance and assessment techniques for nuclear weapon related software  

Energy Technology Data Exchange (ETDEWEB)

Sandia National Laboratories has the qualification evaluation responsibility for the design of certain components intended for use in nuclear weapons. Specific techniques in assurance and assessment have been developed to provide the quality evidence that the software has been properly qualified for use. Qualification Evaluation is a process for assessing the suitability of either a process used to develop or manufacture the product, or the product itself The qualification process uses a team approach to evaluating a product or process, chaired by a Quality Assurance professional, with other members representing the design organization, the systems organization, and the production agency. Suitable for use implies that adequate and appropriate definition and documentation has been produced and formally released, adequate verification and validation activities have taken place to ensure proper operation, and the software ...

1993-12-31

383

A survey of point of care testing in Irish hospitals: room for improvement  

British Library Electronic Table of Contents (United Kingdom)

Background ?Guidelines for safe and effective management and use of point of care testing? have been recently launched in Ireland. Aims To survey point of care testing (POCT) services in the Republic of Ireland. Methods A questionnaire covering accreditation status, existence of POCT committees, quality management systems, and staff resources was distributed by the Irish External Quality Assessment Scheme (IEQAS). Results Of those that returned completed questionnaires, 56% had assigned specific POCT responsibilities to designated staff. Most support was for blood gases and glucose analysis. Compared with other published studies, Irish laboratories gave similar support for blood gases, less for glucose and much less for urinalysis. Conclusions This survey demonstrated poor IT support for P...

2011-01-01

384

Tree fruit IPM programs in the western United States: the challenge of enhancing biological control through intensive management  

British Library Electronic Table of Contents (United Kingdom)

The seminal work of Stern and his coauthors on integrated control has had a profound and long-lasting effect on the development of IPM programs in western orchard systems. Management systems based solely on pesticides have proven to be unstable, and the success of IPM systems in western orchards has been driven by conservation of natural enemies to control secondary pests, combined with pesticides and mating disruption to suppress the key lepidopteran pests. However, the legislatively mandated changes in pesticide use patterns prompted by the Food Quality Protection Act of 1996 have resulted in an increased instability of pest populations in orchards because of natural enemy destruction. The management system changes have made it necessary to focus efforts on enhancing biological control n...

2009-01-01

385

Interventional MR imaging: Clinical results obtained with a 1.5 Tesla system; Interventionelle MR-Tomographie: Klinische Erfahrungen mit einem 1,5 Tesla System  

Energy Technology Data Exchange (ETDEWEB)

The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.) [Deutsch] Es wurde die klinische Durchfuehrbarkeit interventioneller Techniken an einem kombinierten Durchleuchtungs- und MR-Arbeitsplatz untersucht. Dieses Hybridsystem erwies sich bei einer Vielzahl interventioneller Eingriffe als vorteilhaft. Der 1,5 Tesla-Magnet ist offenen MR-Systemen hinsichtlich Bildqualitaet und Messzeit ueberlegen. (orig.)

1997-05-01

386

Automation techniques for fully automated coil transport; Kanzen jido koiru hanso wo jitsugen shita jidoka gijutsu  

Energy Technology Data Exchange (ETDEWEB)

Kawasaki Steel started the construction of an automatic steel strip coil transportation system in the 1980's. Presently, most of the in-plant transportation of hot-rolled or cold-rolled coils are automated. For establishing the automatic transportation, there were developed various technologies, such as, the optimum handling technology using artificial intelligence, the technology of preventing additional piling of coils on existing coils by using an ultrasonic wave and a laser beam. Through the improvements of these technologies, a full-automated transportation system has been achieved and the system has contributed substantially toward product quality assurance and cost reduction. This paper gives the changes in the automation technology of coil transportation in the automation of No. 3 finishing hot rolling mill, now having the latest automatic system, in Chiba Works. ...

1999-12-01

387

Computer aided research system its framework and scopes. Kenkyu kaihatsu shien system wo kangaeru  

Energy Technology Data Exchange (ETDEWEB)

Discussions were given on the current status of research systems and problems that occur in structuring the systems. The purpose is to improve efficiency and quality of the research flows, that is to better arrange the research infrastructures. Among the researches, the developmental researches of products and production techniques constitute the important factor of an integrated production system. Input information and output information must be determined in each developmental process, and the ways of internal processing must be arranged and structured. The basic proposition for structuring an aid system is to clarify what material development this system can bring about, what scenario can be drawn for the material development as its result, and what element technology is required for that scenario in what form and at what level. Discussions are required on ...

1991-07-05

388

US Department of Energy investments in natural gas R&D: An analysis of the gas industry proposal  

Energy Technology Data Exchange (ETDEWEB)

The natural gas industry has proposed an increase in the DOE gas R&D budget from about $100 million to about $250 million per year for each of the next 10 years. The proposal includes four programs: natural gas supplies, fuel cells, natural gas vehicles and stationary combustion systems. This paper is a qualitative assessment of the gas industry proposal and recommends a natural gas R&D strategy for the DOE. The methodology is a conceptual framework based on an analysis of market failures and the energy policy objectives of the DOE`s (1991) National Energy Strategy. This framework would assist the DOE in constructing an R&D portfolio that achieves energy policy objectives. The natural gas supply program is recommended to the extent that it contributes to energy price stability. Stationary combustion programs are supported on grounds of economic efficiency and environmental quality. The fuel cell program is supported on grounds of ...

1992-04-13

389

The 300 Area Integrated Field Research Challenge Quality Assurance Project Plan  

Energy Technology Data Exchange (ETDEWEB)

Pacific Northwest National Laboratory and a group of expert collaborators are using the U.S. Department of Energy Hanford Site 300 Area uranium plume within the footprint of the 300-FF-5 groundwater operable unit as a site for an Integrated Field-Scale Subsurface Research Challenge (IFRC). The IFRC is entitled Multi-Scale Mass Transfer Processes Controlling Natural Attenuation and Engineered Remediation: An IFRC Focused on the Hanford Site 300 Area Uranium Plume Project. The theme is investigation of multi-scale mass transfer processes. A series of forefront science questions on mass transfer are posed for research that relate to the effect of spatial heterogeneities; the importance of scale; coupled interactions between biogeochemical, hydrologic, and mass transfer processes; and measurements/approaches needed to characterize and model a mass transfer-dominated system. This Quality Assurance Project Plan provides the ...

2009-04-29

390

Series fan-powered boxes: Their impact on indoor air quality and comfort  

Energy Technology Data Exchange (ETDEWEB)

Until the concerns about indoor air quality (IAQ) reached a peak in the last five years, interior zones of office buildings were traditionally served with cooling-only shut-off variable air volume (VAV) boxes. Heat gains from lighting and equipment, in addition to those from occupants themselves, caused supply air quantities of 13 C to 15 C (55 F to 60 F) air to be sustained at rates on the order of 2.5 L/s per square meter (0.5 cfm per square feet), a rate that most designers at the time felt would provide a comfortable and well ventilated environment. More recently, the reduction in lighting loads, the use of cold air systems, and, most importantly, the concern that acceptable indoor air quality may not be maintained at low air flow rates, has led to a different solution in interior zones: the series fan-powered mixing box.

1996-07-01

391

Root Architecture of Jarrah (Eucalyptus marginata) Trees in Relation to Post-Mining Deep Ripping in Western Australia  

British Library Electronic Table of Contents (United Kingdom)

Abstract This research aimed to investigate coarse root systems of Jarrah (Eucalyptus marginata Donn ex Sm.) trees at a 13-year-old restored bauxite mine site in south-western Australia. Excavations in an area with small trees (low-quality site) revealed that deep ripping equipment failed to penetrate the cemented lateritic subsoil, restricting coarse roots (roots >5 mm in diameter) to the top 0.5 m of the soil profile, resulting in fewer (1,344 stems/ha) and smaller (mean height 4.5 m) Jarrah trees. An adjacent area within the same pit (high-quality site), with a stand density of 3,256 stems/ha and a mean height of 8.0 m, had a kaolinitic clay subsoil which coarse roots penetrated to the average ripping depth (1.5 m). Trees at the low-quality site did not penetrate the subsoil with their ...

2007-01-01

392

Nanocontact heteroepitaxy of thin GaSb and AlGaSb films on Si substrates using ultrahigh-density nanodot seeds.  

Science.gov (United States)

A film of GaSb grown epitaxially on a Si substrate is a direct transition semiconductor useful for application as a light source in Si photonics and channel material in next-generation field effect transistors because its energy bandgap is close to the optical fibre communication wavelength and it possesses high carrier mobility. Here, we report a novel method for heteroepitaxial growth of high-quality GaSb/Si films, despite having a lattice mismatch as large as ? 12%, using elastically strain-relaxed GaSb nanodots with ultrahigh density as seed crystals for film growth. The nanodot seed crystals were grown epitaxially by restricted contact with the Si substrate through nanowindows in an ultrathin SiO(2) film on the Si substrate. A light-emitting diode containing GaSb/Si films with a thickness of ? 90 nm fabricated by this method operated at room temperature. The growth method was also used to fabricate AlGaSb films of high quality. Our method ...

2011-05-17

393

Construction of a homogeneous phantom for radiographic image standardization; Construcao de um fantoma homogeneo para padronizacao de imagens radiograficas  

Energy Technology Data Exchange (ETDEWEB)

The principle of radiodiagnosis consists in the fact the X-ray beam is attenuated at different degrees by distinct tissues. For this reason, the anatomical structures have distinct radiological opacities, that produce the radiographic image. The progresses in radiology are related to the development if new radiographic image formation systems that enable an amplification in the quality, with low dose and/or risk to the patient. The objective of this work is the sensitometric valuation of a screen-film combination, that is still the most used, for the standardization, of radiographic images. Thinking about this, were constructed homogeneous phantoms of the chest, skull and pelvis, for the calibration of X-ray beams, with the purpose of obtaining radiographic images of good quality, basing in the routine of a radiodiagnosis service and in the scientific knowledge. Questions were approached about the choice of the suitable ...

1996-12-31

394

A tool for the LHCb MWPC production monitoring the LNF on-line database  

CERN Document Server

The LHCb Muon detector system is made of several (1368) Multi Wire Proportional Chambers (MWPCs). Those chambers differ in size, readout and constructing materials and are built in various countries: their assembly takes place in different sites and foresee many steps. To ensure the production quality and keep track of panels/chambers production an on-line database has been set up. This web based tool allows an easy sharing of the information: the database update is made possible trough a web interface. The update is easy and reliable. The interface helps the information sharing in different sites and helps optimizing the production rate by allowing feedback on production needs and quality between sites contributing to the production chain. The planning is made using the information on the material availability. Quality tests and crosschecks are made easier, as well as the overall production monitoring. ...

2006-01-01

395

Simultaneous absolute and differential operation of eddy current bobbin probes for heat exchanger tube inspection  

Energy Technology Data Exchange (ETDEWEB)

Here the authors try to dissolve some commonly held misconceptions about the operation of eddy current probes used for inspecting heat exchanger tubes. With the help of computer model results, the authors demonstrate that, for optimized operation, absolute/differential probes should be operated with coil current flowing in phase with another. This month's feature should be of interest to researchers as well as for NDT field personnel.

2000-05-01

396

Inspection, a practised art?; Revisionen, eine geuebte Praxis?  

Energy Technology Data Exchange (ETDEWEB)

Revisions at steam turbines should present a problem-free procedure due to the long use of these machines. Changes in the market result in difficulties during the inspection work. The shortage of qualified personnel and manufacturing capacities are the cause for these difficulties. Important procedures of revisions are described in detail in the VGB regulations. Direct contacts between the customers and the suppliers facilitate the expirations substantially. In the case of good planning and under consideration of the well-known regulations, a revision can be accomplished to the satisfaction of customers and suppliers.

2008-07-01

397

Short term hydroelectric power system scheduling with wind turbine generators using the multi-pass iteration particle swarm optimization approach  

Energy Technology Data Exchange (ETDEWEB)

This paper uses multi-pass iteration particle swarm optimization (MIPSO) to solve short term hydroelectric generation scheduling of a power system with wind turbine generators. MIPSO is a new algorithm for solving nonlinear optimal scheduling problems. A new index called iteration best (IB) is incorporated into particle swarm optimization (PSO) to improve solution quality. The concept of multi-pass dynamic programming is applied to modify PSO further and improve computation efficiency. The feasible operational regions of the hydro units and pumped storage plants over the whole scheduling time range must be determined before applying MIPSO to the problem. Wind turbine power generation then shaves the power system load curves. Next, MIPSO calculates hydroelectric generation scheduling. It begins with a coarse time stage and searching space and refines the time interval between two time stages and the search spacing pass by ...

2008-04-15

398

Managing high-bandwidth real-time data storage  

Energy Technology Data Exchange (ETDEWEB)

There exist certain systems which generate real-time data at high bandwidth, but do not necessarily require the long-term retention of that data in normal conditions. In some cases, the data may not actually be useful, and in others, there may be too much data to permanently retain in long-term storage whether it is useful or not. However, certain portions of the data may be identified as being vitally important from time to time, and must therefore be retained for further analysis or permanent storage without interrupting the ongoing collection of new data. We have developed a system, Mahanaxar, intended to address this problem. It provides quality of service guarantees for incoming real-time data streams and simultaneous access to already-recorded data on a best-effort basis utilizing any spare bandwidth. It has built in mechanisms for reliability and indexing, can scale upwards to meet increasing bandwidth requirements, ...

2009-01-01

399

Low-temperature brown rice storage by using renewable energy from snow  

Energy Technology Data Exchange (ETDEWEB)

This paper reported on a study that was conducted in Japan to determine whether renewable energy generated from snow can be used to replace the cooling system and electricity used for cooling a rice storehouse that maintained the grain temperature below 15 degrees C. However, the low-temperature storage system required a cooling system and electricity to cool rice in summer. In this study, a snow pile using 890 t of snow was made at the beginning of March next to the rice storehouse. The shape of the snow pile was a trapezium, 17 x 23 m at the bottom and 4 x 10 m at the top and 5 m in height. The snow pile was covered with 200 to 300 mm of wood chips to act as an insulation layer. Approximately 27 per cent of the energy for cooling the rice storehouse could be replaced by using the snow pile in summer. The quality of stored rice was almost similar to that of freshly harvested rice. The study showed that ...

2010-07-01

400

Higher Education in East Asia and Singapore: Rise of the Confucian Model  

Science.gov (United States)

The paper reviews Asia-Pacific higher education and university research, focusing principally on the "Confucian" education nations Japan, Korea, China, Hong Kong China, Taiwan, Singapore and Vietnam. Except for Vietnam, these systems exhibit a special developmental dynamism--still playing out everywhere except Japan--and have created a distinctive model of higher education more effective in some respects than systems in North America, the English-speaking world and Europe where the modern university was incubated. The Confucian Model rests on four interdependent elements: (1) strong nation-state shaping of structures, funding and priorities; (2) a tendency to universal tertiary participation, partly financed by growing levels of household funding of tuition, sustained by a private duty, grounded in Confucian values, to invest in education; (3) "one chance" national examinations that mediate social competition and university hierarchy and focus ...

2011-05-01

401

Healthy Buildings and Green Building Rating Systems; Gezond bouwen en duurzaamheidslabels  

Energy Technology Data Exchange (ETDEWEB)

The awareness of health issues related to buildings has heightened past decades. Indoor Environmental Quality (IEQ) has been addressed in most Green Building Rating Systems nowadays. This article analyses the scope of IEQ (Indoor Environmental Quality) within Rating Systems GPR Gebouw, BREEAM-NL (Dutch version of Building Research Establishment's Environmental Assessment Method) and LEED (Leadership in Energy and Environmental Design). Each Rating System allocates health aspects. However, none of these Rating Systems addresses a complete set of relevant aspects. High ratings do not guarantee healthy buildings. It is concluded that, in general, credits for energy efficiency do not interfere with credits for enhanced indoor environmental quality. [Dutch] Gezondheidsaspecten van gebouwen hebben afgelopen decennia steeds meer en ...

2010-11-15

402

IEA HPP Annex 29 - ground-source heat pumps overcoming technical and market barriers. Status report Norway  

International Nuclear Information System (INIS)

Norway is a member of Annex 29, 'Ground-Source Heat Pump Systems Overcoming Technical and Market Barriers' (2004-2006), organized under the umbrella of the International Energy Agency (IEA) and the IEA Heat Pump Programme (HPP). The 7 participating countries are Austria (Operating Agent), Canada, Japan, Norway, Spain, Sweden and the USA. The Norwegian participation is financed by ENOVA SF, and SINTEF Energy Research is responsible for planning and carrying out the Norwegian activities. This report provides a status for ground-source heat pump (GSHP) systems in Norway with regard to state-of-the-art technology, installation examples, geological data, costs and market opportunities. A Norwegian Internet home page for ground-source heat pump systems (www.energy.sintef.no/prosjekt/Annex29) is also presented. GSHP systems in Norway are classified as direct systems (groundwater and ...

403

Production of jet fuel using heavy crude oil; Producao de combustiveis de aviacao a partir de petroleos pesados  

Energy Technology Data Exchange (ETDEWEB)

The production of heavy crude oils increased in the last years in the world. Crude oils with high density, viscosity, acidity and sulfur, nitrogen, metals and asphaltenes contents, by the others hand, low stability and low product quality. The challenger of many refiners is find solutions to refine the heavy crude oils, and produce fuels with certify quality, such as Jet Fuel. The principal aviation technique on the world work with gas turbines engines feted for jet fuel (JET A1). The quality specifications of this fuel are establish by International Norms: ASTM-1655, DEF STAN 91-91-3 (DERD 2494) and joint Fuelling System Check List. The world technologies to obtain jet fuel from mixtures of heavy crude oil with middle crude oils are: Atmospheric distillation, with a posterior hydrogenation and finally the additivation. Studies carried out have demonstrates that the Cubans heavy crude oils is ...

2004-07-01

404

Development of food preservation and processing techniques by radiation  

International Nuclear Information System (INIS)

Development of food preservation and processing techniques by radiation was performed. Gamma irradiation at 2-10 kGy is considered to be an effective method to control pathogenic bacteria in species including Escherichia coli O157:H7. Gamma irradiation at 5 kGy completely eliminated pathogenic bacteria in beef. Gamma irradiation at such doses and subsequent storage at less than 4 deg C could ensure hygienic quality and prolong the microbiological shelf-life resulting from the reduction of spoilage microorganisms. Gamma irradiation on pre-rigor beef shortens the aging-period, improves tenderness and enhances the beef quality. And, a new beef processing method using gamma irradiation, such as in the low salt sausage and hygienic beef patty was developed. Safety tests of gamma-irradiated meats(beefs: 0-5 kGy; porks: 0-30 kGy) in areas such as genotoxicity, acute toxicity, four-week oral toxicity, rat hepato carcinogenesis and the anti oxidative ...

1988-04-18

405

Canon's flat-panel detector  

International Nuclear Information System (INIS)

We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curve, modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ)) for Cannon's flat-panel detector (FPD), Fuji computed radiography (FCR) and screen-film (S/F) systems, respectively. First, the digital and overall characteristic curves of FPD and FCR systems were more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of FPD system were better than those of FCR system a little at lower spatial frequencies than 0.8 mm"-"1, but the overall MTF of FPD and FCR systems were worse than that of S/F system a little at all spatial frequencies. Third, the digital and overall WS of FPD system were similar or better than those of FCR system, but the ...

2002-12-01

406

Canon's flat-panel detector  

Energy Technology Data Exchange (ETDEWEB)

We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curve, modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ)) for Cannon's flat-panel detector (FPD), Fuji computed radiography (FCR) and screen-film (S/F) systems, respectively. First, the digital and overall characteristic curves of FPD and FCR systems were more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of FPD system were better than those of FCR system a little at lower spatial frequencies than 0.8 mm{sup -1}, but the overall MTF of FPD and FCR systems were worse than that of S/F system a little at all spatial frequencies. Third, the digital and overall WS of FPD system were similar or better than those of FCR ...

2002-12-01

407

Enhanced defect detection and sizing accuracy using matrix phased array ultrasonic tools  

Energy Technology Data Exchange (ETDEWEB)

Although ultrasonic testing inspection technology and tools have improved significantly, there is still a need for more reliable detection, monitoring, and accurate sizing of crack-like and planar defects, complex corrosion damage, and detection of secondary features within deformed pipe. Ultrasonic two dimensional (2D) matrix phased array technology offers some unique advantages that make the technology promising for improving detection and sizing of pipeline flaws resulting from welding or from in-service damage. Ultrasonic modeling and simulation has been conducted to evaluate the detection and sizing capabilities of 2D matrix arrays for various pipeline inspection concepts. Simulations have been performed using both flexible and rigid array probes. Inspection concepts using rigid probes were evaluated for inspections from both the outside and inside pipe surfaces, while flexible probes were ...

2009-07-01

408

Truck tactics: dispatch from Vancouver  

Energy Technology Data Exchange (ETDEWEB)

Any mine that uses haultrucks has a dispatching system of some sort, even if it is only a very basic and simple arrangement. The larger, more complex operations have found that, if properly applied, automated computerised dispatching improves the productivity of the equipment as well as improving overall control and reporting. However, not every mine can justify going this far; in these cases a computerised monitoring and reporting system with manual dispatching can still give considerable benefits. Wenco International Mining Systems of Vancouver supplies its computerised system to three different specification levels to suit most open pit mining operations. The article describes the 3 PMCSs (Production Monitoring and Control System) available: PMCS 1000, for monitoring and reporting only; PMCS 2000, for dispatching to maximise production; and PMCS 3000, for dispatching with ...

1991-11-01

409

Regulatory requirements for design of safety related computer based control Systems in Indian PHWRs: case study of DPHS-PCS for TAPP-3 and 4  

International Nuclear Information System (INIS)

Computer based control systems for safety related applications in nuclear power plants have to meet not only the functional, performance and interface requirements, they in addition, have to meet regulatory requirements like enhanced reliability, safety and security and should provide fault tolerance, diagnostics and self-supervision. The control system architecture, hardware design and software design should meet requirements as specified in design code and guides of AERB. The Dual Processor Hot Standby Process Control System (DPHS-PCS) for TAPP-3 and 4 is a safety related (Class- IB) system. DPHS-PCS regulates PHT pressure, Pressuriser pressure, Pressuriser level, Bleed condenser pressure, Bleed condenser level and Steam generator pressure. The performance, reliability and safety requirements of this control system are met by employing a fault tolerant computer configuration ...

2005-03-01

410

Evaluation of FCR system by means of NEQ(u)  

Energy Technology Data Exchange (ETDEWEB)

A number of noise equivalent quanta (NEQ(u)) has been used in the evaluation of imaging systems. In this paper, we have evaluated the image quality of Fuji computed radiography (FCR) using of NEQ (u) and considered with the effects of the aliasing error of the FCR. The noise samples of the FCR were made by three different exposure levels, and one of these has the same exposure level of the screen-film system. These samples were set with the same characteristic curve condition as that of the screen-film system. Results indicate that NEQ (u) of the FCR system at low frequencies varies depending on the exposure level. On the same exposure level, NEQ(u) of screen-film system has a higher value than that of FCR in the frequency region over 2.5 cycles/mm. Moreover, the aliasing error of FCR increases at the frequency region over 5 cycles/mm. We concluded that it is ...

1991-07-01

411

Evaluation of FCR system by means of NEQ(u)  

International Nuclear Information System (INIS)

A number of noise equivalent quanta (NEQ(u)) has been used in the evaluation of imaging systems. In this paper, we have evaluated the image quality of Fuji computed radiography (FCR) using of NEQ (u) and considered with the effects of the aliasing error of the FCR. The noise samples of the FCR were made by three different exposure levels, and one of these has the same exposure level of the screen-film system. These samples were set with the same characteristic curve condition as that of the screen-film system. Results indicate that NEQ (u) of the FCR system at low frequencies varies depending on the exposure level. On the same exposure level, NEQ(u) of screen-film system has a higher value than that of FCR in the frequency region over 2.5 cycles/mm. Moreover, the aliasing error of FCR increases at the frequency region over 5 cycles/mm. We concluded that it is ...

1991-01-01

412

The importance of radiation quality for optimisation in radiology  

UK PubMed Central (United Kingdom)

Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available

413

Pacific Northwest Laboratory FY 1993 Site Maintenance Plan for maintenance of DOE nonnuclear facilities  

Energy Technology Data Exchange (ETDEWEB)

This Site Maintenance Plan has been developed for Pacific Northwest Laboratory's (PNL) Nonnuclear Facilities. It is based on requirements specified by US Department of Energy (DOE) Order 4330.4A, Chapter I, Change No. 4. The objective of this maintenance plan is to provide baseline information for compliance to the DOE Order 4330.4A, to identify needed improvements, and to document the planned maintenance budget for Fiscal Year (FY) 1993 and to estimate maintenance budgets for FY 1994 and FY 1995 for all PNL facilities. Using the results of the self-assessment, PNL has selected 12 of the 36 elements of the Maintenance Program defined by DOE Order 4330.4A, Chapter I, for improvement. The elements selected for improvement are: Facility Condition Inspections; Work Request (Order) System; Formal Job Planning and Estimating; Work Performance (Time) Standards; Priority System; Maintenance Procedures and Other ...

1992-09-28

414

Pacific Northwest Laboratory FY 1993 Site Maintenance Plan for maintenance of DOE nonnuclear facilities  

Energy Technology Data Exchange (ETDEWEB)

This Site Maintenance Plan has been developed for Pacific Northwest Laboratory`s (PNL) Nonnuclear Facilities. It is based on requirements specified by US Department of Energy (DOE) Order 4330.4A, Chapter I, Change No. 4. The objective of this maintenance plan is to provide baseline information for compliance to the DOE Order 4330.4A, to identify needed improvements, and to document the planned maintenance budget for Fiscal Year (FY) 1993 and to estimate maintenance budgets for FY 1994 and FY 1995 for all PNL facilities. Using the results of the self-assessment, PNL has selected 12 of the 36 elements of the Maintenance Program defined by DOE Order 4330.4A, Chapter I, for improvement. The elements selected for improvement are: Facility Condition Inspections; Work Request (Order) System; Formal Job Planning and Estimating; Work Performance (Time) Standards; Priority System; Maintenance Procedures and Other Work-Related ...

1992-09-28

415

Analysis of log rate noise in Ontario's CANDU reactors  

Energy Technology Data Exchange (ETDEWEB)

In the fall of 2003, the operators noticed that in the recently-refurbished Bruce A Shutdown System no. 1 (SDS1) the noise level in Log Rate signals were much larger than before. At the request of the Canadian Nuclear Safety Commission (CNSC), all Canadian CANDU reactors took action to characterize their Log Rate noise. Staff of the Inspection and Maintenance Services division of Ontario Power Generation (OPG) has collected high-speed high-accuracy noise data from nearly all 16 Ontario reactors, either as part of routine measurements before planned outages or as a dedicated noise recording. This paper gives the results of examining a suitable subset of this data, with respect to the characteristics and possible causes of Log Rate noise. The reactor and instrumentation design is different at each station: the locations of the moderator injection nozzles, the location of the ion chambers for each system, and the design of the ...

2007-07-01

416

A statistical pattern recognition paradigm for structural health monitoring  

Energy Technology Data Exchange (ETDEWEB)

The process of implementing a damage detection strategy for aerospace, civil and mechanical engineering infrastructure is referred to as structural health monitoring (SHM). Here damage is defined as changes to the material and/or geometric properties of these systems, including changes to the boundary conditions and system connectivity, which adversely affect the system's current or future performance. Our approach is to address the SHM problem in the context of a statistical pattern recognition paradigm (Farrar, Nix and Doebling, 2001). In this paradigm, the process can be broken down into four parts: (1) Operational Evaluation, (2) Data Acquisition, (3) Feature Extraction, and (4) Statistical Model Development for Feature Discrimination. When one attempts to apply this paradigm to data from 'real-world' structures, it quickly becomes apparent that data cleansing, normalization, fusion and ...

2004-01-01

417

The Burrard utilization study report: Review and analysis of the future role of Burrard Thermal Generating Station  

Energy Technology Data Exchange (ETDEWEB)

The Burrard Thermal Generating Station is located at Port Moody, British Columbia, and burns natural gas to supply steam to six turbine units for generating up to 912 MW of electricity. The Burrard plant accounts for ca 8.7% of the provincial generating capability. Burrard is expected to continue to fill a vital role as a supplier of displaceable firm energy to the British Columbia Hydro system. In parallel with a renewed focus on Burrard from a system planning perspective, there have also been concerns about air pollution from the plant in the context of its possible effect on the region's air quality. To address this and other issues surrounding Burrard's future, B.C. Hydro established a project team to conduct a utilization study. The team's work focused on the role of Burrard in providing a reliable and profitable role in electricity generation, the options for dealing with the air ...

1993-01-01

418

Enterprise energy management : Part 1  

Energy Technology Data Exchange (ETDEWEB)

The needs of large industrial, commercial, and institutional energy consumers are more closely connected with the needs of power utilities and energy services companies, a result of the evolving global energy environment. Consumer choice, competition amongst energy suppliers, and increased demand are brought about in some regions by deregulation. Increasingly, large energy consumers expect high levels of quality and reliability from the energy delivered. As a result, management of the cost and the quality of the energy product and the energy assets that produce, deliver, control and consume it requires different strategies. Three major challenges must be overcome: (1) requirement to support economic and efficient delivery, purchasing and use of energy, (2) requirement to guarantee higher levels of power quality and reliability, and (3) requirement to supply the growing demand for energy while establishing a market-based ...

2001-09-01

419

Quality assurance handbook for measurement laboratories  

International Nuclear Information System (INIS)

This handbook provides guidance in the application of quality assurance to measurement activities. It is intended to help those persons making measurements in applying quality assurance to their work activities by showing how laboratory practices and quality assurance requirements are integrated to provide control within those activities. The use of the guidance found in this handbook should help provide consistency in the interpretation of quality assurance requirements across all types of measurement laboratories. This handbook also can assist quality assurance personnel in understanding the relationships between laboratory practices and quality assurance requirements. The handbook is composed of three chapters and several appendices. Basic guidance is provided by the three chapters. In Chapter 1, the role of quality assurance in obtaining ...

420

The systemic perspective of service processes: underlying theory, architecture and approach  

British Library Electronic Table of Contents (United Kingdom)

As competition in the service industry grows, delivering high-quality service to meet customers' needs and expectations becomes paramount. In order to achieve a thorough understanding of customers, companies are increasingly adopting Customer Relationship Management (CRM) initiatives. However, CRM does not have the process vision necessary to cope with complex and cross-functional processes. This problem is better handled by Business Process Management (BPM) initiatives, which, by their turn, struggle to built-in customer intelligence in their systems. Based upon systems theory, we discuss the roles of CRM and BPM in an integrated approach to deliver customer fulfillment. As the evolution of service-oriented approaches requires us to consider both customer interactions and experiences as k...

2008-01-01

421

Sustainable Manufacturing System Focusing on the Natural Growth of Bamboo  

Science.gov (United States)

Recently, sustainable materials have attracted attention because of the need to alleviate environmental problems. Bamboo, in particular, has attracted attention as a sustainable material because it has the fastest natural growth rate among various natural materials. A self-bonding fiberboard using high quality bamboo fiber extracted with a machining center has been enabled to be fabricated by hot press forming. Therefore, we propose a sustainable manufacturing system that focuses on bamboo. An environmental impact of our system was evaluated by life cycle assessment (LCA), comparing with a glass fiber reinforced plastic production. Additionally, based on the LCA result, higher efficient fiber extraction process was proposed by an application of in-situ measurement of uninformed bamboo shape with irregularity.

422

Short-term impacts of air pollutants in Switzerland: Preliminary scenario calculations for selected Swiss energy systems  

Energy Technology Data Exchange (ETDEWEB)

In the frame of the comprehensive assessment of Swiss energy systems, air quality simulations were performed by using a 3-dimensional photo-chemical dispersion model. The objective is to investigate the impacts of pollutants in Switzerland for future options of Swiss energy systems. Four scenarios were investigated: Base Case: simulations with the projected emissions for the year 2030, Scenario 1) all nuclear power plants were replaced by oil-driven combined cycle plants (CCP), Scenarios 2 to 4) traffic emissions were reduced in whole Switzerland as well as in the cities and on the highways separately. Changes in the pollutant concentrations and depositions, and the possible short-term impacts are discussed on the basis of exceedences of critical levels for plants and limits given to protect the public health. (author) 2 figs., 7 refs.

1999-08-01

423

Short term hydroelectric power system scheduling with wind turbine generators using the multi-pass iteration particle swarm optimization approach  

British Library Electronic Table of Contents (United Kingdom)

This paper uses multi-pass iteration particle swarm optimization (MIPSO) to solve short term hydroelectric generation scheduling of a power system with wind turbine generators. MIPSO is a new algorithm for solving nonlinear optimal scheduling problems. A new index called iteration best (IB) is incorporated into particle swarm optimization (PSO) to improve solution quality. The concept of multi-pass dynamic programming is applied to modify PSO further and improve computation efficiency.The feasible operational regions of the hydro units and pumped storage plants over the whole scheduling time range must be determined before applying MIPSO to the problem. Wind turbine power generation then shaves the power system load curves. Next, MIPSO calculates hydroelectric generation scheduling. It beg...

2008-01-01

424

Preliminary Fabry Perot testing - 1986  

Science.gov (United States)

Fabry Perot interferometry is a method of determining instantaneous velocities of an object in motion. The interferometer system is composed of the Fabry Perot interferometer, a laser, an electronic streak camera, and several focusing lenses. The first tests discussed were done on exploding bridgewire devices. During these tests, several system parameters were changed. These changes did not seem to affect the data, which appeared to be consistent. The second tests performed focused on slapper-type devices. It was determined that sandblasted, vapor-deposited aluminum on the slapper material would be required to yield quality data. Streak camera failure prevented much data from being collected. An effort is being made to replace the current streak camera. After it is replaced, a Fabry Perot and velocity interferometry system for any reflector comparison will be made. The results will be published as the ...

1987-04-30

425

Portal localization images using computed radiography for high-energy electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy electron beam therapy. (author)

2002-09-01

426

Gas sensor arrays (electronic noses) and their combination with trap techniques  

Energy Technology Data Exchange (ETDEWEB)

In the food, chemical and safety industry there is a demand for gas detectors for process control applications, like quality control of food or leakage control in chemical plants. Gas sensor array systems have the potential to be used in this areas, with the advantage of being also affordable systems compared to other systems like gaschromatographs (GC) or infrared detectors (NIR, FTIR). One of the main drawbacks of the gas sensors is their response to non interesting ambient factors like temperature, pressure and humidity. Metal oxide sensors (MOS) have a low ambient temperature and pressure dependency. Some of them (SnO + dopands) have some sensitivity to humidity. In many cases the response of the sensors is often non-linear, which implies a concentration dependant pattern of the samples. (orig.)

2001-07-01

427

Collaborative Search Trails for Video Search  

CERN Document Server

In this paper we present an approach for supporting users in the difficult task of searching for video. We use collaborative feedback mined from the interactions of earlier users of a video search system to help users in their current search tasks. Our objective is to improve the quality of the results that users find, and in doing so also assist users to explore a large and complex information space. It is hoped that this will lead to them considering search options that they may not have considered otherwise. We performed a user centred evaluation. The results of our evaluation indicate that we achieved our goals, the performance of the users in finding relevant video clips was enhanced with our system; users were able to explore the collection of video clips more and users demonstrated a preference for our system that provided recommendations.

2009-01-01

428

Capturing the Daylight Dividend  

Energy Technology Data Exchange (ETDEWEB)

Capturing the Daylight Dividend conducted activities to build market demand for daylight as a means of improving indoor environmental quality, overcoming technological barriers to effective daylighting, and informing and assisting state and regional market transformation and resource acquisition program implementation efforts. The program clarified the benefits of daylight by examining whole building systems energy interactions between windows, lighting, heating, and air conditioning in daylit buildings, and daylighting's effect on the human circadian system and productivity. The project undertook work to advance photosensors, dimming systems, and ballasts, and provided technical training in specifying and operating daylighting controls in buildings. Future daylighting work is recommended in metric development, technology development, testing, training, education, and outreach.

2006-04-30

429

A Multi-Layered Image Cache for Scientific Visualization  

Energy Technology Data Exchange (ETDEWEB)

We introduce a multi-layered image cache system that is designed to work with a pool of rendering engines to facilitate an interactive, frameless, asynchronous rendering environment. Our system decouples the rendering from the display of imagery. Therefore, it decouples render frequency and resolution from display frequency and resolution, and allows asynchronous transmission of imagery instead of the compute/send cycle of standard parallel systems. It also allows local, incremental refinement of imagery without requiring all imagery to be re-rendered. Images are placed in fixed position in camera (vs. world) space to eliminate occlusion artifacts. Display quality is improved by increasing the number of images. Interactivity is improved by decreasing the number of images.

2003-06-26

430

Increased Mercury Bioaccumulation Follows Water Quality Improvement  

International Nuclear Information System (INIS)

Changes in physical and chemical characteristics of aquatic habitats made to reduce or eliminate ecological risks can sometimes have unforeseen consequences. Environmental management activities on the U.S. Dept. of Energy reservation in Oak Ridge, Tennessee,have succeeded in improving water quality in streams impacted by discharges fi-om industrial facilities and waste disposal sites. The diversity and abundance of pollution-sensitive components of the benthic macroinvertebrate communities of three streams improved after new waste treatment systems or remedial actions reduced inputs of various toxic chemicals. Two of the streams were known to be mercury-contaminated from historical spills and waste disposal practices. Waterborne mercury concentrations in the third were typical of uncontaminated systems. In each case, concentrations of mercury in fish, or the apparent biological availability of mercury increased over the ...

431

Air pollution exposure monitoring and estimating. Part 1: Integrated air quality monitoring system  

Energy Technology Data Exchange (ETDEWEB)

This paper presents an integrated exposure monitoring system, based on an expansion of existing air quality monitoring systems using dispersion modelling. The system allows: (1) identifying geographical areas whose inhabitants are most exposed to ambient pollution; (2) identifying how many people in an area are exposed to concentrations of pollution exceeding air quality guidelines: (3) describing the exposure of population subgroups (e.g. children): (4) planning pollution abatement measures and quantifying their effects; (5) establishing risk assessment and management programs, and (6) investigating the short- and long-term effects of both pollutants and pollution sources on public health. The effect of pollution is rarely very large and in order to discover it, exposure estimation must provide data that reflects both spatial and temporal variations. Estimates of pollution exposure ...

1999-08-01

432

Phantom and animal imaging studies using PLS synchrotron X-rays  

CERN Document Server

Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and inexpensive ultra-high resolution imaging ...

2001-01-01

433

Impact of independent power producers in a deregulated system  

Energy Technology Data Exchange (ETDEWEB)

Independent power producers (IPPs) have had open access to existing power systems ever since the electric power industry was restructured and deregulated. IPPs are small-scale, distributed, and independently operated. Introducing an IPP to the power system can be beneficial to the existing power system because it can increase the security margin or reduce production cost and environmental pollution. The disadvantage is that some IPPs are not subject to dispatch control, consequently, they may reduce the network security. Often IPPs use co-generation, small-scale hydro, even fuel cells or other types of renewable energy sources. An evaluation of IPPs impact on an existing utility power system was determined in a modified IEEE 14 bus system. The total generating cost, environmental impact, transmission line margin, voltage profile, network congestion, security and other power ...

1997-04-01

434

Water Quality and 401 Certification | Clean Water Act | US EPA  

Science.gov (United States)

Clean Water Act You are here: Water Laws & Regulations Policy & Guidance Clean Water Act Water Quality and 401 Certification Water Quality and 401 Certification Water Quality...

2011-08-28

444

Utility activities that create power quality problems  

Energy Technology Data Exchange (ETDEWEB)

Power quality problems are caused by activities normal to utility operations such as maintenance outages and capacitor switching or events that are abnormal such as lightning strikes and equipment failures. Disconnection and reconnection of transmission lines and transformers can cause switching surges, and are more severe on extra high voltage transmission lines than high voltage lines. Capacitor switching can cause transients and harmonics that may affect sensitive equipment, and are the source of 3rd, 5th, 7th and 9th harmonics in the hundreds of hertz ranges. Overload, sudden loss of generating capacity and transmission line faults are typical problems affecting system stability. Fault interruptions and reclosings can cause surges in the distribution system, and lightning strikes may cause voltage surges or dips due to arrester sparkover. Blackouts, brownouts, voltage fluctuations, travelling wave overvoltages, ...

1992-02-01

445

Use of morphine sulfate (MS Contin) in patients with burns: a pilot study.  

Science.gov (United States)

Morphine sulfate (MS Contin), a proven analgesic in the treatment of cancer pain and chronic benign pain, seems to be a good analgesic for the treatment of burn pain. MS Contin is morphine sulfate incorporated in a wax cellulose matrix delivery system. This wax cellulose delivery system gives MS Contin its duration of action. Ten patients were enrolled in an open-labeled, nonrandomized study. The study was designed to examine the analgesic efficacy of MS Contin in the burn population. Each patient remained in the study for 6 days. The efficacy of the analgesic regimen was subjectively measured by the visual pain scale. The MS Contin group was retrospectively compared with a group of patients who were given continuous intravenous infusions of morphine. The two groups were matched according to age, burn size, surgical procedures, and hospital stay. The analgesic qualities of MS Contin were comparable to those of continuous ...

446

Untersuchung von Bildqualitat und Genauigkeit der Dosisberechnung bei cone-beam-CT-Aufnahmen mit reduziertem Projektionsdatensatz (half scan, half fan) im Hinblick auf die Verwendbarkeit fur die adaptive Bestrahlungsplanung  

British Library Electronic Table of Contents (United Kingdom)

Subject of this study is the question of whether cone beam CT (CBCT) images with reduced projection data are suitable for use in adaptive radiation therapy (ART) treatment planning. For this purpose image quality and dose calculation accuracy depending on imaging modality were analysed. In this context, two CBCT-methods will be indicated having reduced projection data sets: Scans acquired with 200^o rotation angle in order to accelerate the CBCT process (half scan), or scans with an asymmetric cone beam and detector offset, used to enlarge the field-of-view (half fan). Methods: For three different CBCT-modes (On-Board-Imaging, Varian Medical Systems), two of them based on reduced projection data, and a conventional multidetector CT system, the main image quality parameters were studied. Tr...

2011-01-01

447

Transport of a power plant tracer plume over Grand Canyon National Park  

Energy Technology Data Exchange (ETDEWEB)

Meteorological and air-quality data, as well as surface tracer concentration values, were collected during 1990 to assess the impact of Navajo Generating Station (NGS) emissions on Grand Canyon National Park (GCNP) air quality. These data have been used in the present investigation to determine between direct and indirect transport routes taken by the NGS plume to produce measured high-tracer concentration events at GCNP. Results show that complex-terrain features affect local wind-flow patterns during winter in the Grand Canyon area. Local channelling, decoupled canyon winds, and slope and valley flows dominate in the region when synoptic systems are weak. Direct NGS plume transport to GCNP occurs with northeasterly plume-height winds, while indirect transport to the park is caused by wind direction shifts associated with passing synoptic systems. Calculated polluted airmass positions along the modeled ...

1999-08-01

448

The dosimetric verification of a pencil beam based treatment planning system  

International Nuclear Information System (INIS)

A new three-dimensional treatment planning system (TPS) based on convolution/superposition algorithms (TMS-Radix from HELAX AB, Uppsala, Sweden) was recently installed at the University Hospital in Lund. The purpose of the present study was to design a quality assurance and acceptance testing programme to meet the specific characteristics of this convolution model. The model is based on parametrization of a non-measurable quantity - the polyenergetic pencil beam. However, the verification of the treatment planning model is still dependent on numerous comparisons of measured depth-doses and dose profiles. The test programme was divided in two basic parts: (i) model implementation and beam data consistency and (ii) model performance and limitations in special situations. The first part was scheduled for all photon beam qualities available before they could be used for clinical treatment planning. The second part was performed ...

449

Performance of the upgraded LTP-II at the ALS Optical Metrology Laboratory  

Energy Technology Data Exchange (ETDEWEB)

The next generation of synchrotrons and free electron laser facilities requires x-ray optical systems with extremely high performance, generally of diffraction limited quality. Fabrication and use of such optics requires adequate, highly accurate metrology and dedicated instrumentation. Previously, we suggested ways to improve the performance of the Long Trace Profiler (LTP), a slope measuring instrument widely used to characterize x-ray optics at long spatial wavelengths. The main way is use of a CCD detector and corresponding technique for calibration of photo-response non-uniformity [J. L. Kirschman, et al., Proceedings of SPIE 6704, 67040J (2007)]. The present work focuses on the performance and characteristics of the upgraded LTP-II at the ALS Optical Metrology Laboratory. This includes a review of the overall aspects of the design, control system, the movement and measurement regimes for the stage, and analysis of the ...

2008-07-14

450

Multilayer reflective coatings for extreme-ultraviolet lithography  

Energy Technology Data Exchange (ETDEWEB)

Multilayer mirror coatings which reflect extreme ultraviolet (EUV) radiation are a key enabling technology for EUV lithography. Mo/Si multilayers with reflectances of 67.5% at 13.4 nm are now routinely achieved and reflectances of 70 2% at 11.4 nm were obtained with MO/Be multilayers. High reflectance is achieved with careful control of substrate quality, layer thicknesses, multilayer materials, interface quality, and surface termination. Reflectance and film stress were found to be stable relative to the requirements for application to EUV lithography. The run-to-run reproducibility of the reflectance peak position was characterized to be better than 0.2%, providing the required wavelength matching among the seven multilayer-coated mirrors used in the present lithography system design. Uniformity of coating was improved to better than 0.5% across 150 mm diameter substrates. These improvements in EUV multilayer mirror ...

1998-03-10

451

Improving the PSA quality in the human reliability analysis of pre-accident human errors  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the activities for improving the Probabilistic Safety Assessment (PSA) quality in the human reliability analysis (HRA) of the pre-accident human errors for the Korea Standard Nuclear Power Plant (KSNP). We evaluate the HRA results of the PSA for the KSNP and identify the items to be improved using the ASME PRA Standard. Evaluation results show that the ratio of items to be improved for pre-accident human errors is relatively high when compared with the ratio of those for post-accident human errors. They also show that more than 50% of the items to be improved for pre-accident human errors are related to the identification and screening analysis for them. In this paper, we develop the modeling guidelines for pre-accident human errors and apply them to the auxiliary feedwater system of the KSNP. Application results show that more than 50% of the items to be improved for the pre-accident human errors of the auxiliary feedwater ...

2004-07-01

452

Improving the PSA quality in the human reliability analysis of pre-accident human errors  

International Nuclear Information System (INIS)

This paper describes the activities for improving the Probabilistic Safety Assessment (PSA) quality in the human reliability analysis (HRA) of the pre-accident human errors for the Korea Standard Nuclear Power Plant (KSNP). We evaluate the HRA results of the PSA for the KSNP and identify the items to be improved using the ASME PRA Standard. Evaluation results show that the ratio of items to be improved for pre-accident human errors is relatively high when compared with the ratio of those for post-accident human errors. They also show that more than 50% of the items to be improved for pre-accident human errors are related to the identification and screening analysis for them. In this paper, we develop the modeling guidelines for pre-accident human errors and apply them to the auxiliary feedwater system of the KSNP. Application results show that more than 50% of the items to be improved for the pre-accident human errors of the auxiliary feedwater ...

2004-06-06

453

Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures  

Energy Technology Data Exchange (ETDEWEB)

AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image ...

2002-04-01

454

Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures  

International Nuclear Information System (INIS)

AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image ...

2002-04-01

455

Control system fabrication of fuel elements and assepblies for the FFTF reactor  

International Nuclear Information System (INIS)

The procedure and operation-by-operation methods of the quality control of structural and fuel materials, mixed fuel pellets of UO_2-PuO_2, fuel element cans made of the AISI-316 steel and ready fuel elements are described as well as spacer wires (steel AISI-316), cases of fuel assemblies (FA) and completed FAs. The methods are used in manifacturing fuel elements and FAs for the FFTF reactor. The RDT standards that regulate the structure and functioning of the system of fuel element and FA production management are outlined. Destructive analytical methods characterized by sufficient accuracy but low productivity are noted to represent a considerable share of operations. Some specialized means of nondestructive testing are developed, such as the gauge to measure the total plutonium content in a fuel element, neutron radiography deVice and a laser gauge to measure the FA dimensions. The experience gained served as a basis for designing the ...

456

Control system fabrication of fuel elements and assemblies for the FFTF reactor  

Energy Technology Data Exchange (ETDEWEB)

The procedure and operation-by-operation methods of the quality control of structural and fuel materials, mixed fuel pellets of UO/sub 2/-PuO/sub 2/, fuel element cans made of the AISI-316 steel and ready fuel elements are described as well as spacer wires (steel AISI-316), cases of fuel assemblies (FA) and completed FAs. The methods are used in manifacturing fuel elements and FAs for the FFTF reactor. The RDT standards that regulate the structure and functioning of the system of fuel element and FA production management are outlined. Destructive analytical methods characterized by sufficient accuracy but low productivity are noted to represent a considerable share of operations. Some specialized means of nondestructive testing are developed, such as the gauge to measure the total plutonium content in a fuel element, neutron radiography deVice and a laser gauge to measure the FA dimensions. The experience gained served as a basis for designing ...

1984-01-01

457

CR portal imaging; A linac graphy using storage phosphor imaging systems  

Energy Technology Data Exchange (ETDEWEB)

In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In computed radiography, image processing (tone scale modification and edge enhancement) is possible, and is advantageous portal ...

1992-07-01

458

A method of predicting pressure profiles in horizontal 37-element clusters  

International Nuclear Information System (INIS)

A new two-phase friction multiplier correlation has been developed to predict the pressure profile in two-phase flow with heat addition. The main difference from other pressure drop prediction routines is that in addition to the effect of quality, the effects of system pressure, heat and mass flux on the two-phase multiplier are included. The inception of two-phase flow is defined to occur at the onset of significant void in the subcooled boiling regime instead of the boundary between negative and positive thermodynamic equilibrium quality. Pressure drop data from an experiment with a fully segmented 6-metre long, 37-element fuel string were used to optimize the constants and exponents of this correlation for the friction multiplier. This pressure drop prediction technique was shown to successfully predict the measured pressure profiles. The more than one hundred overall pressure drop data were predicted with an RMS error ...

1983-04-18

459

Steam generator access modification and waterlance cleaning for Wolsong and other nuclear plants  

International Nuclear Information System (INIS)

Steam generators for nuclear plants require access to the primary and secondary side for various inspection, cleaning and repair procedures and upon achieving access various inspection and cleaning tasks must be carried out. Steam generators currently at manufacture are therefore provided with; primary side access via the primary manways, steam drum access via the steam drum manway, U-bend region access via the secondary manway and drum-internals access passages, tubesheet secondary side access via tubesheet level inspection ports and tube support plate access via tube support level access ports. Many CANDU steam generators were built with only primary and drum manways and either no tubesheet ports or ports which were located ineffectively. The steam generators at Wolsong 1 were built with secondary side inspection ports that provided only limited access away from the no-tube-lane. In addition they have ...

2002-05-05

460

Field trial of a fast single-pass transmit-receive probe during Gentilly II steam generator tube inspection  

International Nuclear Information System (INIS)

A new generation of transmit-receive single-pass probes, denoted as C6 or X probe, was field tested during the Gentilly II, 2000 steam generator tube inspection. This probe has a performance equivalent to rotating probes and can be used for tubesheet and full-length inspection at an inspection speed equivalent to that of bobbin probes. Existing C3 transmit-receive probes have been demonstrated to be effective in detecting circumferential cracks. The C5 probe can detect both circumferential and axial cracks and volumetric defects but cannot discriminate between them. The C6 probe expands on the capabilities of both probes in a single probe head. It can simultaneously detect and discriminate between circumferential and axial cracks to satisfy different plugging criteria. It has excellent coverage, good defect detectability, and improved sizing and characterization. Probe data is displayed in C-scan format so that the amount ...

2000-11-19

461

EPA: Environmental Quality and Recreation: Global Warming  

Science.gov (United States)

Archived Web resource. Information about the impacts of global warming on the environmental quality and recreation, such as ... ...

462

Ventilation by the windows in classrooms: a case study  

Energy Technology Data Exchange (ETDEWEB)

Four classrooms of two secondary schools located around Lyon in France have been monitored. The objectives are to analyse the quality of the indoor air and the thermal comfort and also the behaviour of the occupants towards opening of the windows. This paper briefly describes the context and the nature of the monitoring campaign, and presents the results of the measurements with direct interpretation of the ventilation needs. Results from this study show that allowable CO{sub 2} levels are overpassed several times in a school day. The presence of a mechanical ventilation system leads to lower peaks but the fresh airflow is too small to prevent an indoor confining, that is also revealed by the aerobiological analysis. (author)

1994-12-31

463

Solar-powered refrigerator unit with solar module and transport equipment as stand-alone compact system. Solarkuehlgeraet mit Solarmodul und Transportvorrichtung als autonomes Kompaktsystem  

Energy Technology Data Exchange (ETDEWEB)

A compact and energy independent solar-powered refrigeration unit was to be developed to store and transport small quantities of high-quality commodities needing refrigeration. This unit comprises the following matched components: thermo-electrical refrigerator unit, solar generator and transport equipment. The solar generator is a specially developed panel with 36 cells. This unit may best be used in human medicine, veterinary medicine, environmental protection analysis, laboratories and leisure time activities. (BWI)

1994-01-01

464

Orbit of the double-mode cepheid Y Carinae  

Energy Technology Data Exchange (ETDEWEB)

The double-mode cepheid Y Car has been found to have a variable centre-of-mass velocity. Though the observations did not cover a cycle, an orbital period of about 400-600 days was estimated. Radial-velocity observations of this star have now been continued in order to derive the orbital elements. Observations were made with the photoelectric radial-velocity spectrophotometer at the coude focus of the 1.88-m reflector at Sutherland. The velocity system was standardized by frequent nightly observations of stars in the Mount Wilson catalogue with 'a'-quality radial velocities.

1983-06-01

465

Facility Safety Plan B360 Complex Biohazardous Operations CMLS-412r0  

Science.gov (United States)

This Addendum to the Facility Safety Plan (FSP) 360 Complex describes the safety requirements for the safe conduct of all biohazardous research operations in all buildings within the 360 complex program areas. These requirements include all the responsibilities and authorities of building personnel, operational hazards, and environmental concerns and their controls. In addition, this Addendum prescribes facility-specific training requirements and emergency controls, as well as maintenance and quality assurance requirements for ES&H-related building systems.

2007-01-08

466

Development of an injection molding tool for complex microfluidic geometries  

British Library Electronic Table of Contents (United Kingdom)

This paper will track the design and results of an injection molding tool developed to manufacture microfluidic chips. The mold design and injection molding process was complicated by the presence of integrated capillary fluidic interconnects. We determined that design of the runner and gate system responsible for delivering molten plastic to the cavity had a significant impact on the quality of parts produced by the mold and the size of the process window. Numerical results confirm our findings that reducing gate lengths and increasing part thickness dramatically improved the filling profile and lowered injection pressures by 37%. Finally, the influence of gate location on part shrinkage is analyzed and discussed.

2011-01-01

467

DWPF Melter No.2 Prototype Bus Bar Test Report  

Energy Technology Data Exchange (ETDEWEB)

Characterization and performance testing of a prototype DWPF Melter No.2 Dome Heater Bus Bar are described. The prototype bus bar was designed to address the design features of the existing system which may have contributed to water leaks on Melter No.1. Performance testing of the prototype revealed significant improvement over the existing design in reduction of both bus bar and heater connection maximum temperature, while characterization revealed a few minor design and manufacturing flaws in the bar. The prototype is recommended as an improvement over the existing design. Recommendations are also made in the area of quality control to ensure that critical design requirements are met.

2003-03-26

468

Controlled serial compensator for load control and excess-current release. Geregelter Serienkompensator fuer Lastflussregelung und Ueberstrombegrenzung  

Energy Technology Data Exchange (ETDEWEB)

With the compensator-series equipment put into operation in 1992 - giving a performance of 330 Mvar - it was made possible for high-performance electronics to use a continuously variable, fully loaded power transmission line and to regulate the energy flow and minimise overcurrent losses. As well as these technical qualities, this system could offer environmental advantages for European implementation. This would avoid the need to plan and construct new high voltage transmission lines in order to meet increased demand. (orig.)

1994-06-01

469

Biotoxicity characterization of a produced-water discharge in Wyoming  

International Nuclear Information System (INIS)

The objectives of this paper are to document the physicochemical and aquatic toxicological quality of a beneficial-use produced-water discharge and its effect on a receiving stream in Wyoming. Fish and water-flea survival, growth, and reproduction tests indicated that the discharge and all other sampling stations passed the state effluent biomonitoring acute toxicity testing endpoints. while benthic macroinvertebrates were absent at the discharge point designated by the Natl. Pollutant Discharge Elimination System (NPDES), productive and reproducing populations were present at all other downstream and mixing-zone stations. This investigation confirmed the validity of the beneficial-use subcategory for this oilfield discharge.

470

Biogas supply to the natural gas supply grid. Study; Einspeisung von Biogas in das Erdgasnetz. Studie  

Energy Technology Data Exchange (ETDEWEB)

Biogas supply to the public gas grid is a new option discussed in the most recent publication of Fachagentur Nachwachsende Rohstoffe (FNR) e.V. The biogas is purified, upgraded to natural gas quality and fed into an existing gas grid. Once there, it can be transported across long distances and also used for electric power generation at the consumer side. The study investigates inhowfar and in what instances this method is feasible and promising. It discusses the technical background and the regional potential of biogas. Seven model biogas systems are presented as examples. (orig.)

2006-07-01

471

A study on reliability of electro-hydraulic governor control system for large steam turbine in power plant  

Energy Technology Data Exchange (ETDEWEB)

In this work, the right management procedure for hydraulic power oil will be discussed and suggested. A thermal power plant turbine should respond to the change of load status. However, to satisfy the frequency of alternating current, the revolution per minute should be kept constant. Therefore, by controlling the flow rate of the steam to the turbine, the governor satisfies the load variation without alternating the revolution per minutes of the turbine. To protect the governor, the hydraulic power unit should be managed carefully by controlling the quality and the flow rate of the oil.

2008-07-01

472

3. forum solar practice. Proceedings; 3. Forum Solarpraxis. Solartechnik: Markt + Finanzen, Marketing + Verkauf. Tagungsband  

Energy Technology Data Exchange (ETDEWEB)

This proceedings volume contains contributions by about 70 authors on market trends, funding, marketing, boundary conditions and sales promotion of thermal solar energy and photovoltaic systems. The contributions reflect the diversity of authors, e.g. consultants, advocates and agents of solar technology producers and financial organisations. Central issues were markets in and outside Europe, quality assurance, interdepartmental cooperations, and marketing strategies of the solar industry. The proceedings volume also contains the conference schedule and self-descriptions of the authors' institutions. (orig.)

2002-07-01

473

Investigation of acoustic waves generated in an elastic solid by a pulsed ion beam and their application in a FIB based scanning ion acoustic microscope  

International Nuclear Information System (INIS)

The aim of this work is to investigate the acoustic wave generation by pulsed and periodically modulated ion beams in different solid materials depending on the beam parameters and to demonstrate the possibility to apply an intensity modulated focused ion beam (FIB) for acoustic emission and for nondestructive investigation of the internal structure of materials on a microscopic scale. The combination of a FIB and an ultrasound microscope in one device can provide the opportunity of nondestructive investigation, production and modification of micro- and nanostructures simultaneously. This work consists of the two main experimental parts. In the first part the process of elastic wave generation during the irradiation of metallic samples by a pulsed beam of energetic ions was investigated in an energy range from 1.5 to 10 MeV and pulse durations of 0.5-5 #mu#s, applying ions with different masses, e.g. oxygen, silicon and gold, in charge states from 1"+ to 4"+. The acoustic amplitude ...

474

Health-hazard evaluation report HETA 84-427-1613, Pikes Peak Dialysis Center, Colorado Springs, Colorado  

Energy Technology Data Exchange (ETDEWEB)

Environmental and breathing zone samples were analyzed for formaldehyde at the Pikes Peak Dialysis Center, Colorado Springs, Colorado in August, 1984 and February, 1985. The evaluation was requested by a representative of the Center to determine if there was a health hazard due to formaldehyde. Eight employees were interviewed. The ventilation systems were investigated. Personal protective clothing was inspected. Breathing-zone samples contained 0 28 to 1.0 (mg/m/sup 3/) formaldehyde. The OSHA standard for formaldehyde is 3.7 mg/m/sup 3/. Area formaldehyde concentrations ranged from nondetectable to 0.75 mg/m/sup 3/. Health complaints reported included sore throat, congestion, cough, and eye, nose and throat irritation. Most of the complaints originated from employees in the formalin mixing, reuse sterilization, and dialysis unit packing sections. The exhaust system in the reuse sterilization area was not working ...

1985-08-01

475

Compatibility analysis of DUPIC fuel (part 3) - radiation physics analysis  

International Nuclear Information System (INIS)

As a part of the compatibility analysis of DUPIC fuel in CANDU reactors, the radiation physics calculations have been performed for the CANDU primary shielding system, thermal shield, radiation damage, transportation cask and storage. At first, the primary shield system was assessed for the DUPIC fuel core, which has shown that the dose rates and heat deposition rates through the primary shield of the DUPIC fuel core are not much different from those of natural uranium core because the power levels on the core periphery are similar for both cores. Secondly, the radiation effects on the critical components and the themal shields were assessed when the DUPIC fuel is loaded in CANDU reactors. Compared with the displacement per atom (DPA) of the critical component for natural uranium core, that for the DUPIC fuel core was increased by -30% for the innermost groove and the weld points and by -10% for the corner of the calandria subshells and annular ...

2009-07-01

476

Application of neutron radiography systems in JRR-3M to nuclear engineering  

Energy Technology Data Exchange (ETDEWEB)

Initial major applications of neutron radiography (NR) to nuclear engineering were nondestructive inspections of nuclear fuel, control rods, reactor materials and some other components. Increase in the available neutron flux over 10{sup 8} n/cm{sup 2}s at the JRR-3M thermal neutron radiography facility (TNRF) in 1991 has expanded the application field to the dynamic but clear imaging of moving objects and fluid phenomena. The JRR-3M TNRF is facilitated with three major imaging systems, being characterized by spatial and/or temporal resolutions: 1. Static neutron radiography (SNR), 2. real-time neutron radiography (RNR) with an imaging rate of 30 frames/s and 3. High-frame-rate neutron radiography (HFRNR). SNR has been used for three-dimensional visualization of air-water two-phase flows in a simulated rod bundle. Three-dimensional computed tomography clearly illustrated average void fraction distributions around tie spacers. RNR has been used ...

1999-07-01

477

Three-terminal electric transport measurements on gold nano-particles combined with ex situ TEM inspection  

International Nuclear Information System (INIS)

We have fabricated nanometer-spaced electrodes on electron-transparent silicon nitride membranes. A thin Cr/Au layer is evaporated on the backside of the membrane which serves as a gate electrode. Using these devices, we have performed three-terminal electron transport measurements on gold nano-particles at liquid helium temperature. Coulomb Blockade features have been observed and the capacitance to the gate has been extracted. After transport measurements, the Cr/Au back gate is removed and the devices are inspected with a transmission-electron microscope (TEM). TEM inspection reveals the presence of a few nano-particles in the nanogap, which is in agreement with the transport measurements. In addition, the nano-particle size as observed by TEM coincides with the one estimated from the gate capacitance value.

2009-10-14

478

Special eddy current probes for heat exchanger inspection  

International Nuclear Information System (INIS)

Until a decade ago, only the differential bobbin type eddy current probe was considered necessary for reliable heat exchanger tube inspection. The introduction of different tube materials, manufacturing processes and a variety of service induced failures has greatly increased the demands of eddy current testing. Optimized probe designs enhanced by improved instrumentation can help satisfy some of these demands. Some of the more difficult inspection problems are detection of circumferential cracks, fretting wear under non-ferromagnetic support plates and shallow internal defects. Reliable detection and sizing of such defects is often made more difficult by the fact they frequently occur in defect prone regions such as under tubesheets or support plates and in transition regions of finned tubes. Probe designs effective in overcoming these difficulties exist. This paper describes a number of such probes and their performance.

1986-11-17

479

Intervention device, especially for control, inspection and maintenance of heat exchangers. Dispositif d'intervention, notamment pour le controle, l'inspection et la maintenance des echangeurs de chaleur  

Energy Technology Data Exchange (ETDEWEB)

The steam generator inspection and maintenance device has an articulated arm formed at least by two rigid segments connected by a pivot and two plates on the ends of the arms by articulated joints which enable them to rotate about two orthogonal axis. One of the axis is parralel to the axis of the pivot between the arm sections while the other is perpendicular to the surface of the corresponding plate. Each of the plates carries coupling elements which are able to engage with the perforations of the heat exchanger tube plates and also a support for a maintenance tool.

1990-09-21

480

Development of SDT sensor based eddy current probe for detection of deep fatigue cracks in multi-layer structure  

British Library Electronic Table of Contents (United Kingdom)

The detection and characterization of deeply buried fatigue damage in thick, multi-layer airframe components pose significant technical challenges to the aviation safety community. Currently, no nondestructive evaluation technique is available to reliably detect such potential damage from the exterior of the airframe, which is highly desirable in light of inspection cost as well as avoidance of structure damage. Recent technological advances in high-sensitivity magnetic sensors, i.e., spin-dependent tunneling (SDT) sensors, make it feasible to employ electromagnetic inspection techniques for deep fatigue crack inspection. In this work, we report on the development and fabrication of a low frequency eddy current probe based on a magnetically shielded SDT pickup sensor concentrically located...

2010-01-01

481

High air quality and low energy consumption. Performance of hybrid ventilation with CO2-sensors; Hoge luchtkwaliteit en lage energiebesparing. Goede prestaties van hybride ventilatie met CO2-sensoren  

Energy Technology Data Exchange (ETDEWEB)

The school building complex Waterland in The Hague, Netherlands, was built with a hybrid ventilation system. The indoor environment and energy consumption were monitored for one year. Air quality and thermal comfort are of a high quality and the consumption of energy for heating is circa 35% lower than normal. The Waterland project was one of eight demonstration projects, carried out within the framework of the ECBS-Annex 35: Hybrid ventilation in New and retrofitted Office Buildings. ECBS stands for the IEA-program Energy Conservation in Buildings and Community Systems. [Dutch] In ECBCs-annex 35 (ECBS staat voor het IEA-programma Energy Conservation in Buildings and Community Systems) is uitgebreid onderzoek gedaan naar hybride ventilatiesystemen in kantoren en scholen. Dit project heeft geleid tot acht internationale voorbeeldprojecten, waarvan scholencomplex Waterland te Den Haag ...

2005-11-01

482

A Human Reliability Analysis of Pre-Accident Human Errors in the Low Power and Shutdown PSA of the KSNP  

International Nuclear Information System (INIS)

Korea Atomic Energy Research Institute, using the ANS Low Power /Shutdown (LPSD)PRA Standard, evaluated the LPSD PSA model of the KSNP, Younggwang (YGN) Units 5 and 6, and identified the items to be improved. The evaluation results of human reliability analysis (HRA) of the pre-accident human errors in the LPSD PSA model of the KSNP showed that 13 items among 15 items of supporting requirements for those in the ANS PRA Standard were identified as them to be improved. Thus, we newly carried out a HRA for pre-accident human errors in the LPSD PSA model for the KSNP to improve its quality. We considered potential pre-accident human errors for all manual valves and control/instrumentation equipment of the systems modeled in the KSNP LPSD PSA model except reactor protection system/ engineering safety features actuation system. We reviewed 160 manual valves and 56 control/instrumentation equipment. The number ...

2003-04-20

483

Energy policy for integrating the building environmental performance model of an air conditioned building in a subtropical climate  

Energy Technology Data Exchange (ETDEWEB)

For an air conditioned building, the major electricity consumption is by the heating, and air conditioning (HVAC) system. As energy saving strategies may be in conflict with the criteria of indoor air quality and thermal comfort, a concept of the building environmental performance model (BEPM) has been developed to optimize energy consumption in HVAC systems without any deterioration of the indoor air quality and thermal comfort. The BEPM is divided into two main modules: the adaptive comfort temperature (ACT) module and the new demand control ventilation (nDCV) module. This study aims to enhance and prompt the conventional operation of the air side systems by incorporating temperature reset with the adaptive comfort temperature control and the new demand control ventilation system in high rise buildings in Hong Kong. A new example weather year (1991) was ...

2006-09-15

484

Real-time monitoring of dosimetry and image quality during digital radiology examinations  

International Nuclear Information System (INIS)

Objective: To explore the feasibility of real-time monitoring exposure dose and image quality by using the data stored in the DICOM image archive of direct digital radiography system. Methods: Model TO. 16 was exposed, the current increased gradually from 0.5 to 125 mAs. The displayed number of model A( diameter 11.1 mm), D (diameter 4.0 mm) and J( diameter 0.7 mm) were recorded, and the detect factors (H_T) was also calculated. Images were sent to workstation before the end of DR examination. An automatic procedure was implemented to extract dose data and exposure parameters from the DICOM header file. Maximum, minimum and 3rd quartile values were preinstalled. Mean values exceeding the threshold trigger alarm signal to guide radiologist to explore the cause. Results: When the current of point A was less than 10 mAs and the current of point D and J were less than 16 mAs, the detect factor (H_T) increased with the rise of current. While point A ...

2009-12-01

485

Optimization of sorghum-methane production systems  

Energy Technology Data Exchange (ETDEWEB)

This dissertation concerns a study of the utilization of sorghum biomass as the fuel for a methane production system. The objective of this research is to determine an optimal sorghum-methane production system based on anaerobic batch digestion technology. The system is described as the interaction of three components: estimation of available biomass, storage of biomass, and the gas production. Levelized costs are obtained for each component. The biomass supply is assumed to decay exponentially in quality with storage time. The gas production process is a batch type of digestion with an exponential production rate. Gas production is formulated for a fixed planning horizon (one year) as a function of the number of batches and the batch residence times. The cost equation is then described as a function of these gas production equations and their levelized costs. The structure of this resulting equation is ...

1984-01-01

486

On-line video image processing system for real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of gray scale and resolved to 240 x 256 picture elements (pixels) on a monochrome CRT, ...

1983-09-15

487

Hardware Testing and System Evaluation: Procedures to Evaluate Commodity Hardware for Production Clusters  

Energy Technology Data Exchange (ETDEWEB)

Without stable hardware any program will fail. The frustration and expense of supporting bad hardware can drain an organization, delay progress, and frustrate everyone involved. At Stanford Linear Accelerator Center (SLAC), we have created a testing method that helps our group, SLAC Computer Services (SCS), weed out potentially bad hardware and purchase the best hardware at the best possible cost. Commodity hardware changes often, so new evaluations happen periodically each time we purchase systems and minor re-evaluations happen for revised systems for our clusters, about twice a year. This general framework helps SCS perform correct, efficient evaluations. This article outlines SCS's computer testing methods and our system acceptance criteria. We expanded the basic ideas to other evaluations such as storage, and we think the methods outlined in this article has helped us choose hardware that is much more stable ...

2004-02-27

488

An on-line video image processing system for real-time neutron radiography  

International Nuclear Information System (INIS)

The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of gray scale and resolved to 240 x 256 picture elements (pixels) on a monochrome CRT, ...

1983-09-01

489

Acceptance testing in digital systems of mammography. Protocols applicability  

International Nuclear Information System (INIS)

Acceptance testing of mammographic imaging systems technical is the first approach in order to guarantee that mammograms will be achieved with the minimum radiation dose compatible with an image quality suitable for diagnose purposes. The aim of this study is to assess the practical applicability of different protocols in acceptance test of digital mammographic systems. This study has been carried out on the results of the acceptance tests of five flat panel digital mammographic systems. Parameters established in the systems technical specifications and those evaluated in the consulted protocols were tested. Due to the fact that the legislation in our country does not demand to consider a specific protocol, the results obtained were also compared considering different existing protocols. Results show discrepancies between manufacturers limiting values and those established in the ...

490

Selection of ancillary data to derive production management units in sweet corn (Zea Mays var. rugosa) using MANOVA and an information criterion  

British Library Electronic Table of Contents (United Kingdom)

In production systems where high-resolution harvest data are unavailable there is often a reliance on ancillary information to generate potential management units. In these situations correct identification of relevant sources of data is important to minimize cost to the grower. For three fields in a sweet corn production system in central NSW, Australia, several sets of high-resolution data were obtained using soil and crop canopy sensors. Management units were derived by k-means classification for 2?5 classes using three approaches: (1) with soil data, (2) with crop data and (3) a combination of both soil and crop data. Crop quantity and quality were sampled manually, and the sample data were related to the different management units using multivariate analysis of variance (MANOVA). The ...

2011-01-01

491

Review of SCDAP/RELAP5 Code Application to severe accident analysis of CANDU Reactors  

International Nuclear Information System (INIS)

SCDAP/RELAP5 code has been developed in US for best-estimate simulation of light water reactors transients during nuclear accidents. The code models the coupled behaviour of the cooling system, reactor core and fission products release during the accident. It is the result of the coupling between RELAP5, modelling thermal hydraulic, control system, reactor kinetics and the transport of noncondensable gases, and SCDAP code modelling the behaviour of the reactor core during severe accidents. The paper briefly presents the application of SCDAP/RELAP5 code to CANDU severe accident analysis. Also, the paper proposes a summary of the needs for development that could enhance the quality of the severe accidents related predictions in CANDU reactors. (authors)

2009-10-12

492

Recommendations for a proposed standard for performing systems analysis  

Science.gov (United States)

In August 1995, the Nuclear Regulatory Commission (NRC) issued a policy statement proposing improved regulatory decisionmaking by increasing the use of PRA [probabilistic risk assessment] in all regulatory matters to the extent supported by the state-of-the-art in PRA methods and data. A key aspect in using PRA in risk-informed regulatory activities is establishing the appropriate scope and attributes of the PRA. In this regard, ASME decided to develop a consensus PRA Standard. The objective is to develop a PRA Standard such that the technical quality of nuclear plant PRAs will be sufficient to support risk-informed regulatory applications. This paper presents examples recommendations for the systems analysis element of a PRA for incorporation into the ASME PRA Standard.

1998-08-01

493

Recommendations for a proposed standard for performing systems analysis  

Energy Technology Data Exchange (ETDEWEB)

In August 1995, the US Nuclear Regulatory Commission (NRC) issued a policy statement proposing improved regulatory decision making by increasing the use of probabilistic risk assessment (PRA) in all regulatory matters to the extent supported by the state-of-the-art in PRA methods and data. A key aspect in using PRA in risk-informed regulatory activities is establishing the appropriate scope and attributes of the PRA. In this regard, the American Society of Mechanical Engineers (ASME) decided to develop a consensus PRA standard. The objective is to develop a PRA standard such that the technical quality of nuclear plant PRAs will be sufficient to support risk-informed regulatory applications. The authors present example recommendations for the systems analysis element of a PRA for incorporation into the ASME PRA standard.

1998-12-31

494

Phthalate monoesters in perfusate from a dual placenta perfusion system, the placenta tissue and umbilical cord blood  

British Library Electronic Table of Contents (United Kingdom)

Fetal exposure to phthalates may be associated with adverse reproductive effects, including cryptorchidism and decreased semen quality. Information about human placental transfer is needed to qualify the hypotheses. A dual recirculating placenta perfusion system to monitor concentrations of eight phthalate monoesters in fetal and maternal perfusates was established. In addition to perfusate background measures of phthalate monoesters, the concentrations in umbilical cord plasma and placenta tissue were measured. Monomethyl phthalate (mMP), monoethyl phthalate (mEP), monobutyl phthalate (mBP), and mono (2-ethyl-hexyl) phthalate (mEHP) were detected in both maternal and fetal perfusate, demonstrating a release of compounds from tissue or blood to perfusates. The distribution of compounds bet...

2007-01-01

495

Model-based fuzzy control of power system static/dynamic security using the pattern recognition approach  

Energy Technology Data Exchange (ETDEWEB)

Using databases derived from the pattern recognition approach, the paper presents a methodology for utilizing fuzzy models to enhance the quality of decision-making using fuzzy-logic algorithms. Two multi-objective fuzzy-logic control algorithms for controlling power system static/dynamic security are presented and analyzed. The first algorithm is based on the successive inferences of fuzzy implication rules for each individual objective, and the second algorithm is an application of the method of fuzzy linear programming. The paper discusses the properties, advantages and limitations of applying fuzzy decision-making logic in the pattern-recognition approach and concludes by highlighting potential areas for further development. (author)

1994-07-01

496

Model-based automation system for demand-based heating and ventilation; Modellgestuetztes Mess- und Automatisierungssystem zur bedarfsgerechten Heizung und Lueftung  

Energy Technology Data Exchange (ETDEWEB)

Better quality of thermal comfort as well as reduced heat energy demand and accordingly CO{sub 2} emission can be achieved by better heating and ventilation strategies in private buildings. The paper deals with a novel model-based measurement and automation system. It describes the implementation of better strategies under given technical circumstances. (orig.) [German] Durch Verbesserung der Heizungs- und Lueftungsstrategien im privaten Lebensbereich kann sowohl Heizenergie eingespart und damit die CO{sub 2}-Emission verringert, als auch die Raumbehaglichkeit verbessert werden. Der Beitrag behandelt ein modellgestuetztes Mess- und Automatisierungssystem, mit dem die Realisierung der verbesserten Strategien unter gegebenen technischen Randbedingungen praktisch erst moeglich wird. (orig.)