WorldWideScience
1

Particle identification by modified Bragg-curve centroid detection  

Energy Technology Data Exchange (ETDEWEB)

A new article identification method based on the measurement of Bragg-curve centroids using a gas-filled ionization chamber has been improved for detection of low-energy particles around 1 MeV per nucleon by introducing a nonuniform distribution of resistance on the anode electrode. Almost the same quality of Z-resolutions as in the conventional ..delta..E-E method could be obtained up to Z=19.

1987-03-01

2

On-line measurement and inspection technologies of surface properties of steel sheets; Koban hyomen hinshitsu no onrain keisoku oyobi kensa gijutsu  

Energy Technology Data Exchange (ETDEWEB)

In steel production lines such as pickling lines, cold rolling mills and coil processing lines, the needs for on-line continuous measurement of surface quality and property of products and on-line inspection of surface defects have become strong. This is because user requirements for the surface quality of various products have become severer than before and besides, expectations are running high on the side of manufacturers for higher speeds of production lines and higher quality by the adoption of automatic inspection. As for the measurement of surface quality, continuous measurements along the full length of a steel strip are required in order to overcome problems derived from off-line, batch measurements that cannot satisfy user's demands for quality assurance. As for surface defects detection, various kinds of methods have been ...

1999-12-01

3

Giant magnetoresistance sensing technologies for detecting small defects in metallic structures  

Science.gov (United States)

Giant magnetoresistance (GMR) has been used with Eddy current testing to detect small defects not only in thin film structures but also in multilayered metallic structures. This work detected small scratches in the thin film under the surface where these defects were unable to be inspected or monitored by regular testing. In addition, rotational GMR magnetic sensor based Eddy current probes were used for detecting buried corner cracks at the edge of holes in metallic structures. The results of this study proved that giant magnetoresistance is very powerful and effective to sense the magnetic field, which is the result from the perturbation of the Eddy currents caused by a defect. This method can be used for quality control of metallization layers on silicon wafer and to detect cracks in thick structures such as cracks in aging aircraft.

2008-01-01

5

Dynamic construction of outage lists for safety analysis of power transmission lines. Dynamische Erstellung von Ausfallisten fuer die Sicherheitsanalyse elektrischer Energieuebertragungssysteme  

Energy Technology Data Exchange (ETDEWEB)

An adaptive contingency selection process is set up which produces outage lists in order to guarantee on-line network security control. The quality index system used so far did not detect and reveal all critical variables due to observation problems in the mapping of two functions. The new process uses the results of the outage simulation computing of the system status just past for the drawing up of an up-to-date outage list. A linear correcting function transform the G{sub 2}-values of the standard quality index method - which still incorporate the observation problem effect - into improved values G. Studies which use data from realstic high-voltage networks prove that the detection of critical variables is far superior to ordinary methods. (orig.).

1990-04-23

6

Lung cancer screening program using annual chest radiographs with computed radiography (FCR)  

Energy Technology Data Exchange (ETDEWEB)

In the Wajima lung cancer screening program conducted under the auspices of Kanazawa University Hospital, Fuji Computed Radiography (FCR) was utilized in a new chest radiography trial. The results of the screening program are that the necessity of repeat examinations due to poor image quality are less common and the method enables detection of small pulmonary nodular shadows which are possibly candidates for surgery. Oblique chest X-ray with FCR is remarkably effective for the detection and the identification of small lesions. However, the disadvantage of slow processing and high cost must be fully satisfied if FCR is to become a new imaging modality for mass screening.

1987-08-01

7

Lung cancer screening program using annual chest radiographs with computed radiography (FCR)  

International Nuclear Information System (INIS)

In the Wajima lung cancer screening program conducted under the auspices of Kanazawa University Hospital, Fuji Computed Radiography (FCR) was utilized in a new chest radiography trial. The results of the screening program are that the necessity of repeat examinations due to poor image quality are less common and the method enables detection of small pulmonary nodular shadows which are possibly candidates for surgery. Oblique chest X-ray with FCR is remarkably effective for the detection and the identification of small lesions. However, the disadvantage of slow processing and high cost must be fully satisfied if FCR is to become a new imaging modality for mass screening. (author).

1987-01-01

8

Non-destructive testing of refractories, especially AZS materials, with ultrasound, microwaves and {gamma}-radiation  

Energy Technology Data Exchange (ETDEWEB)

In principle four different methods (ultrasound, microwaves, {gamma}-radiation and x-rays) are available for the non-destructive testing of refractories. Three of these methods, i.e. ultrasound, microwaves and {gamma}-radiation, are in use by different producers of AZS materials to carry out the quality control of their products. This paper will compare the three methods on the basis of the physical properties, present the existing devices, and show the advantages as well as the limits of the different methods. {gamma}-radiography, the oldest method in use, has one main disadvantage, which is the requirement of protection against radioactive radiation. Furthermore, while cracks and cavities can be detected with this method, structural changes can not be monitored. Therefore, the ultrasonic method was ...

1995-08-01

10

Real-time monitoring of dosimetry and image quality during digital radiology examinations  

International Nuclear Information System (INIS)

Objective: To explore the feasibility of real-time monitoring exposure dose and image quality by using the data stored in the DICOM image archive of direct digital radiography system. Methods: Model TO. 16 was exposed, the current increased gradually from 0.5 to 125 mAs. The displayed number of model A( diameter 11.1 mm), D (diameter 4.0 mm) and J( diameter 0.7 mm) were recorded, and the detect factors (H_T) was also calculated. Images were sent to workstation before the end of DR examination. An automatic procedure was implemented to extract dose data and exposure parameters from the DICOM header file. Maximum, minimum and 3rd quartile values were preinstalled. Mean values exceeding the threshold trigger alarm signal to guide radiologist to explore the cause. Results: When the current of point A was less than 10 mAs and the current of point D and J were less than 16 mAs, the detect factor (H_T) ...

2009-12-01

11

Application of the microbiological method DEFT/APC to detect minimally processed vegetables treated with gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

Marketing of minimally processed vegetables (MPV) are gaining impetus due to its convenience, freshness and apparent health effect. However, minimal processing does not reduce pathogenic microorganisms to safe levels. Food irradiation is used to extend the shelf life and to inactivate food-borne pathogens. In combination with minimal processing it could improve safety and quality of MPV. A microbiological screening method based on the use of direct epifluorescent filter technique (DEFT) and aerobic plate count (APC) has been established for the detection of irradiated foodstuffs. The aim of this study was to evaluate the applicability of this technique in detecting MPV irradiation. Samples from retail markets were irradiated with 0.5 and 1.0 kGy using a {sup 60}Co facility. In general, with a dose increment, DEFT counts remained similar independent of the irradiation while APC counts decreased ...

2009-07-15

12

State-of-the-art techniques for internal quality measurements in steel sheets production processes; Hakkoban seizo ni okeru naibu hinshitsu no onrain keisoku oyobi kensa gijutsu  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the state-of-the-art ultrasonic and magnetic measuring techniques developed at Kawasaki Steel and used in the production process of steel sheets are described. Representative examples shown here are as follows: (1) Magnetic flux leakage testing system for the detection of nonmetallic inclusions, (2) Nondestructive orientation measurement for secondary re-crystallized grains in grain-oriented electrical steel by ultrasonic interferometry, (3) Immersion testing method for the detection of nonmetallic inclusions, (4) Surface wave probe for the detection of surface flaws in rolls used in rolling mills. Developments of these techniques and their applications to actual steel sheets production processes have contributed to advance in technologies for quality assurance and control. With the help of these techniques, steel sheet products with advanced and uniform properties ...

1999-12-01

13

Microdialysis unit for molecular weight separation  

Energy Technology Data Exchange (ETDEWEB)

The present invention relates generally to an apparatus and method for separating high molecular weight molecules from low molecular weight molecules. More specifically, the invention relates to the use of microdialysis for removal of the salt (low molecular weight molecules) from a nucleotide sample (high molecular weight molecules) for ESI-MS analysis. The dialysis or separation performance of the present invention is improved by (1) increasing dialysis temperature thereby increasing desalting efficiency and improving spectrum quality; (2) adding piperidine and imidazole to the dialysis buffer solution and reducing charge states and further increasing detection sensitivity for DNA; (3) using low concentrations of dialysis buffer and shifting the DNA negative ions to higher charge states, producing a nearly 10-fold increase in detection sensitivity and a slightly decreased desalting efficiency, or (4) ...

1999-09-21

14

Eddy current probe development based on a magnetic sensor array; Developpement d'un imageur magnetique pour le controle non destructif par courants de Foucault  

Energy Technology Data Exchange (ETDEWEB)

This research deals with in the study of the use of innovating magnetic sensors in eddy current non destructive inspection. The author reports an analysis survey of magnetic sensor performances. This survey enables the selection of magnetic sensor technologies used in non destructive inspection. He presents the state-of-the-art of eddy current probes exploiting the qualities of innovating magnetic sensors, and describes the methods enabling the use of these magnetic sensors in non destructive testing. Two main applications of innovating magnetic sensors are identified: the detection of very small defects by means of magneto-resistive sensors, and the detection of deep defects by means of giant magneto-impedances. Based on the use of modelling, optimization, signal processing tools, probes are manufactured for these both applications.

2007-06-15

15

Statistical Methods and Software for the Analysis of Occupational Exposure Data with Non-detectable Values  

Energy Technology Data Exchange (ETDEWEB)

Environmental exposure measurements are, in general, positive and may be subject to left censoring; i.e,. the measured value is less than a ''detection limit''. In occupational monitoring, strategies for assessing workplace exposures typically focus on the mean exposure level or the probability that any measurement exceeds a limit. Parametric methods used to determine acceptable levels of exposure, are often based on a two parameter lognormal distribution. The mean exposure level, an upper percentile, and the exceedance fraction are used to characterize exposure levels, and confidence limits are used to describe the uncertainty in these estimates. Statistical methods for random samples (without non-detects) from the lognormal distribution are well known for each of these situations. In this report, methods for estimating these quantities based on ...

2005-09-20

16

MRT versus CT in the diagnosis of pneumonia. Evaluation of a T_2-weighted utrafast turbo-spin-echo sequence (UTSE)  

International Nuclear Information System (INIS)

Purpose: To evaluate a T_2-weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T_2-weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR_e_f_f/T_E/Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis and representation of the lesions, in 25% MRT was superior. MRT was better for the ...

1999-05-01

17

Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures  

Energy Technology Data Exchange (ETDEWEB)

AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the ...

2002-04-01

18

Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures  

International Nuclear Information System (INIS)

AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the ...

2002-04-01

19

Indoor air quality and thermal comfort studies of an under-floor air-conditioning system in the tropics  

Energy Technology Data Exchange (ETDEWEB)

This paper reports thermal comfort and indoor air quality (IAQ) studies of an under-floor air-conditioning (UFAC) system in a hot and humid climate. Thermal comfort parameters were measured at pre-determined grid points within an imaginary plane to predict the air flow pattern of the supply air jet as well as to determine the occurrence of thermal stratification in the office space. Fanger's thermal comfort index was also computed to detect the occupants' thermal sensation. Besides, the concentration levels of dust and carbon dioxide were recorded with the intention to examine the quality of the indoor air. Statistical methods were applied to derive the relationship between air velocity and the other parameters as mentioned earlier. The main findings from the study revealed reasonable level of acceptability of IAQ associated with the UFAC system. However, occupants are likely to ...

2002-07-01

20

The influence of scattered radiation on recording systems and quality-assurance test parameters  

International Nuclear Information System (INIS)

Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).

1988-02-23

21

The influence of scattered radiation on recording systems and quality-assurance test parameters  

International Nuclear Information System (INIS)

Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).

22

Computed radiography. Evaluation of its role in the mass survey for lung cancer: Phantom study  

Energy Technology Data Exchange (ETDEWEB)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in the retrocardiac and subdiaphragmatic ...

1987-12-01

23

Computed radiography  

International Nuclear Information System (INIS)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in the retrocardiac and subdiaphragmatic ...

1987-01-01

24

Quality measurement and control in physician decision making: state of the art.  

UK PubMed Central (United Kingdom)

The status of the concept of controlling the quality of physicians is reviewed as are studies that have been done on methods to measure and improve quality. The conclusions are dismal given the rhetoric...Full Text Available

1982-01-01

25

Advanced phosphors  

Energy Technology Data Exchange (ETDEWEB)

This invention relates to new phosphor materials and to combinatorial methods of synthesizing and detecting the same. In addition, methods of using phosphors to generate luminescence are also disclosed.

2000-01-01

28

A study of the effects of scattered radiation on radiographic quality and methods of elimination of such radiation  

International Nuclear Information System (INIS)

Many mechanical parts are subjected to stresses and strains that may eventually lead to their failure. In order to prevent the costly delays associated with equipment down-time, many parts have to be tested for weaknesses and defects when machinery is constructed or dismantled for maintenance. These procedures are known as Non-Destructive Testing (NDT) methods. Five types of non-destructive testing methods routinely used are radiographic testing, ultrasonic testing, magnetic particle inspection, liquid penetrant testing and eddy current testing. Out of these five techniques industrial radiography plays an important role in non-destructive testing to reveal interior defects in materials. In radiography almost two-thirds of the radiation reaching the film is scattered radiation which does not form the image of defects. Scattered radiation generated inside and outside a material has a very large effect on sensitivity of flaw ...

1998-02-01

29

The LSST Data Mining Research Agenda  

CERN Document Server

We describe features of the LSST science database that are amenable to scientific data mining, object classification, outlier identification, anomaly detection, image quality assurance, and survey science validation. The data mining research agenda includes: scalability (at petabytes scales) of existing machine learning and data mining algorithms; development of grid-enabled parallel data mining algorithms; designing a robust system for brokering classifications from the LSST event pipeline (which may produce 10,000 or more event alerts per night); multi-resolution methods for exploration of petascale databases; indexing of multi-attribute multi-dimensional astronomical databases (beyond spatial indexing) for rapid querying of petabyte databases; and more.

2008-01-01

30

Removal of scattered thermal neutrons using antiscatter grid  

International Nuclear Information System (INIS)

One of the significant factors of neutron radiographic image degradation is scattering blur from the object. A practical method is described to enhance image quality by eliminating the overlapping of scattered thermal neutrons component from the objects in ETRR-2 neutron radiography facility, using aluminum Gd-coated antiscatter grid. The MCNP code was used to determine the optimum grid dimensions that will reduce the scattered thermal neutrons from the object. An experiment was performed to determine the optimum grid height and irradiation time that gives the best image with acceptable geometric unsharpness. Using the MCNP code it was found that 97% of the scattered neutrons were removed by the grid. The wall dimensions and Gd coating are so small that the facility resolution cannot detect the image pattern superposition on the film.

2006-12-01

31

P03-378 - Erectile dysfunction in psychiatric patients  

British Library Electronic Table of Contents (United Kingdom)

Introduction: Erectile dysfunction (ED) is defined as the inability to achieve or maintain an erection sufficient for sexual activity. Objectives: ED is a common condition in psychiatric patients, which can modify their quality of life. Aims: The aim of this study is to assess the prevalence and the severity of ED in psychiatric patients. Methods: This naturalistic, observational study was conducted during a six months period. The International Index of Erectile Function (IIEF) 15-item questionnaire was used to assess 144 male inpatients with different psychiatric disorders. IIEF is a brief, cross-culturally valid, self-administered scale for detecting treatment-related changes in patients with erectile dysfunction and addresses the relevant domains of male sexual function: erectile functi...

2011-01-01

32

Environmental Kuznets curve for CO2 in Canada  

British Library Electronic Table of Contents (United Kingdom)

According to the environmental Kuznets curve hypothesis, the relationship between per-capita GDP and per-capita pollutant emissions has an inverted-U shape. This implies that, past a certain point, economic growth may actually be profitable for environmental quality. Most studies on this subject are based on estimating fully parametric quadratic or cubic regression models. While this is not technically wrong, such an approach somewhat lacks flexibility since it may fail to detect the true shape of the relationship if it happens not to be of the specified form. We use semiparametric and flexible nonlinear parametric modeling methods in an attempt to provide more robust inferences. We find little evidence in favour of the environmental Kuznets curve hypothesis. Our main results could be inte...

2010-01-01

33

Development of the high sensitivity real-time neutron radiography for low-flux neutron sources  

Energy Technology Data Exchange (ETDEWEB)

The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose of developing a system with higher sensitivity, consideration ...

1994-08-01

34

Development of the high sensitivity real-time neutron radiography for low-flux neutron sources  

International Nuclear Information System (INIS)

The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose of developing a system with higher sensitivity, consideration ...

1994-01-01

35

Detection of Microcalcification in Mammograms Using Wavelet Transform and Fuzzy Shell Clustering  

CERN Document Server

Microcalcifications in mammogram have been mainly targeted as a reliable earliest sign of breast cancer and their early detection is vital to improve its prognosis. Since their size is very small and may be easily overlooked by the examining radiologist, computer-based detection output can assist the radiologist to improve the diagnostic accuracy. In this paper, we have proposed an algorithm for detecting microcalcification in mammogram. The proposed microcalcification detection algorithm involves mammogram quality enhancement using multirresolution analysis based on the dyadic wavelet transform and microcalcification detection by fuzzy shell clustering. It may be possible to detect nodular components such as microcalcification accurately by introducing shape information. The effectiveness of the proposed algorithm for microcalcification ...

2010-01-01

36

Improving the Quality of Life  

Wastenet

...and supply ensuring better food quality for the consumer developing safer and more flexible food production processes and technologies raw materials for food production; production and processing systems; by-products and wastes from fisheries and agro-industry; new food sources; packaging systems; quality monitoring; traceability Food contamination detecting and eliminating infectious and toxic agents throughout the food chain establishing the hazards and origins of food contaminants producing food more safely rapid ...

37

Theoretical review of techniques for the remote detection of methane in underground coal mines  

Energy Technology Data Exchange (ETDEWEB)

The nature and relationship of methane to coal mines is discussed and sources of information are outlined. Methods of gas analysis in general and methods for the detection of methane in use in coal mines are described. Methods of remote detection of gases and those that have application for use in underground coal mining operations are discussed. The report represents recommendations on remote methane detection systems that may find application in underground coal mines. (20 refs.)

1983-01-01

38

Development of a universal plate-agglutination test for detecting Haemophilus parasuis  

UK PubMed Central (United Kingdom)

Due to the serovar diversity in Haemophilus (H.) parasuis, it is difficult to develop a universal serological method for detection of this pathogen....Full Text Available

2010-12-01

39

The Health-Related Quality of Life in Long-Term Colorectal Cancer Survivors Study: objectives, methods, and patient sample  

UK PubMed Central (United Kingdom)

ObjectivesThe objective of this paper is to describe the complex mixed-methods design of a study conducted to assess health-related quality of life (HRQOL) outcomes...Full Text Available

2008-07-01

40

MRI in preoperative evaluation of chronic paranasal sinusitis - a comparison with CT  

International Nuclear Information System (INIS)

Purpose: To determine the value of MRI in the preoperative evaluation of chronic paranasal sinusitis and to compare the results with CT and intraoperative findings. Method/Materials: 42 patients with clinical signs of chronic paranasal sinusitis underwent MRI after CT evaluation on one day, with subsequent functional endoscopic sinus surgery on the next day. Coronary CT was obtained with 5-mm slices and table-feed in the prone position, while MRI was performed in the supine position with coronary T_2-TSE+pd and coronary and transverse HASTE, each with 5-mm slice thickness. Aquisition time in MRI was less than 8 minutes. Two radiologists reviewed the CT and MRI scans for signs of sinusitis and detection of anatomical landmarks. The results were correlated with the intraoperative findings. Results: MRI offered no artifacts of dental work and showed more often high quality pictures than CT. CT and MRI demonstrated a good ...

2001-04-01

41

Detection and Toxin Typing of Clostridium perfringens in Formalin-Fixed, Paraffin-Embedded Tissue Samples by PCR?  

UK PubMed Central (United Kingdom)

Since current microbiology methods are not suitable to detect Clostridium perfringens in formalin-fixed, paraffin-embedded tissue samples, we developed a PCR assay to detect toxin-encoding...Full Text Available

2009-03-01

42

Detection and Identification of Ciprofloxacin-Resistant Yersinia pestis by Denaturing High-Performance Liquid Chromatography  

UK PubMed Central (United Kingdom)

Denaturing high-performance liquid chromatography (DHPLC) has been used extensively to detect genetic variation. We used this method to detect and identify Yersinia pestis KIM5 ciprofloxacin-resistant...Full Text Available

2003-07-01

43

Method for detecting and diagnosing disease caused by pathological protein aggregation  

Energy Technology Data Exchange (ETDEWEB)

A method is provided for detecting pathological macromolecules in a patient. The method is comprised of the following: obtaining body fluid from the patient; pretreating the body fluid; subjecting the pretreated body fluid to size-exclusion chromatography to create an excluded fluid; and analyzing the excluded fluid to detect macromolecules having a predetermined molecular weight. The method also allows for comparing elution spectra with reference spectra of suspect pathologic proteins.

2000-05-16

44

Determination of Cinchona alkaloids and Vitamin B_6 by high-performance liquid chromatography with fluorescence detection  

International Nuclear Information System (INIS)

A simple and specific method has been developed for the simultaneous determination of the four major Cinchona alkaloids and their dihydroderivatives and pyridoxine hydrochloride (Vitamin B_6) by high-performance liquid chromatography (HPLC) with fluorescence detection (#lambda#_e_m=420 nm with #lambda#_e_x=330 nm). The chromatographic separation was performed on a Phenomenex Prodigy ODS column (5 #mu#m, 250 mmx3.2 mm i.d.), recommended for basic compounds, under isocratic reversed-phase conditions. The method allowed a good peak shape and an effective resolution of the tested compounds. The extraction of alkaloids from the Cinchona succirubra bark was carried out in mild and fast conditions (ambient temperature, 20 min) by ultrasonication. The procedure showed to be advantageous respect to a reference method, which involved Soxhlet extraction. The results were compared statistically by means of the ...

2004-06-04

45

Quantitative and qualitative aspects of agricultural products  

International Nuclear Information System (INIS)

The following aspects will be discussed: The main function of the Division of Inspection Services and its role in the Marketing of agricultural products; the shelf life of agricultural products: short review of present methods with a practical example of losses incurred due to limited keeping quality; irradiation and heat treatment: advantages of inhibited microbiological activities and undesirable chemical changes from a quality control point of view; quality standards: the basic principles of quality control; consequences of effective post-harvest treatment: export of deciduous and citrus fruit; the magnitude of the problem of poor keeping quality and quality requirements; other fruit; quantities and export limitations and vegetables; quantity and quality requirements; local marketing: fruit and vegetables subjected to ...

46

Grading of quality assurance requirements  

International Nuclear Information System (INIS)

The present Manual provides guidance and illustrative examples for applying a method by which graded quality assurance requirements may be determined and adapted to the items and services of a nuclear power plant in conformance with the requirements of the IAEA Nuclear Safety Standards (NUSS) Code and Safety Guides on quality assurance. The Manual replaces the previous publication IAEA-TECDOC-303 on the same subject. Various methods of grading quality assurance are available in a number of Member States. During the development of the present Manual it was not considered practical to attempt to resolve the differences between those methods and it was preferred to identify and benefit from the good practices available in all the methods. The method presented in this Manual deals with the aspects of management, ...

47

Supervision monitoring for radiation environment around Daya Bay and Lingao nuclear power stations  

International Nuclear Information System (INIS)

This paper systematically introduces the supervision monitoring for radiation environment around the Guangdong Daya Bay and Ling Ao nuclear power station by the Guangdong Environmental Radiation Research and Monitoring Center. It includes the monitoring plan, methods, quality assurance, main results and conclusions. The results show that: (1) The gas discharge have not caused any detectable impacts to the terrestrial and atmospheric environment since their operation; (2) "1"1"0"mAg could only be detected in seawater in the West Daya Bay in 1995 and 1997 and in sediments in 1997. The maximum annual average in seawater was 3.1 Bq/m"3, annual average of "1"1"0"mAg in sediments was 1.0 Bq/kg(dry). But it was always detectable in pearl oyster, gulfweed and cuttlefish in the West Daya Bay. The "1"1"0"mAg concentrations in halobios were relatively higher in 1994, 1996 and 1997. The maximum ...

2004-05-01

48

Optical chemical sensors for atmospheric pollutants based on nano porous materials: application to the formaldehyde and the other carbonyl compounds; Capteurs chimiques a transduction optique de polluants atmospheriques a base de materiaux nanoporeux: application au formaldehyde et autres composes carbonyles  

Energy Technology Data Exchange (ETDEWEB)

Formaldehyde, a well-identified indoor pollutant, was recently classified as carcinogenic. New regulations for the air quality are expected and therefore there is a need for low-cost sensors, sensitive and selective with a fast response time for the detection of formaldehyde at ppb level. In the present work, we had developed a chemical sensor based on nano-porous matrices doped with Fluoral-P and optical methods of detection. The nano-porous matrices, elaborated via the Sol-Gel process, display nano-pores whose cavity is tailored for the trapping of the targeted pollutant. They provide a first selectivity with the discrimination of the pollutants by their size. A second selectivity is obtained with a molecular probe, Fluoral-P, which reacts specifically with formaldehyde leading to the 3,5- di-acetyl-1,4-dihydro-lutidine (DDL). The kinetics of formation of DDL was studied as function of many parameters ...

2006-12-15

49

Key methods for sustaining quality engineering data in nuclear power plants  

International Nuclear Information System (INIS)

This paper discusses key methods for sustaining quality engineering data, the fundamental principles that these methods are based on, and the methods for supporting the performance of nuclear power plants by the provision of quality engineering data at all times. The concept of an 'engineering data foundation', and a Configuration Management data model are developed. The concepts and methods for managing the integrity of engineering data across many different databases and document systems are developed, including the key concepts of data-positions and data-values, Master Data and Copy Data, and the concept of a 'partnership between people and technology'. (author). 7 refs., 1 tab., 2 figs.

1995-06-04

50

Rapid Detection of Ofloxacin Resistance in Mycobacterium tuberculosis by Two Low-Cost Colorimetric Methods: Resazurin and Nitrate Reductase Assays  

UK PubMed Central (United Kingdom)

We have evaluated the performance of two rapid, low-cost methods for the detection of ofloxacin (OFX) resistance with 95 Mycobacterium tuberculosis isolates from countries with high...Full Text Available

2005-04-01

51

Analysis of the Type IV Fimbrial-Subunit Gene fimA of Xanthomonas hyacinthi: Application in PCR-Mediated Detection of Yellow Disease in Hyacinths  

UK PubMed Central (United Kingdom)

A sensitive and specific detection method was developed for Xanthomonas hyacinthi; this method was based on amplification of a subsequence of the type IV fimbrial-subunit gene fimA...Full Text Available

2001-02-01

52

Application of radionuclide X-ray fluorescence analysis to the monitoring of the quality of air  

International Nuclear Information System (INIS)

An X-ray fluorometric train was set up for analyzing gravitational fallout, and tested on standard reference samples of fly ashes from conventional power plants. Analysis of thin layers proved inappropriate, and therefore pelletization of the samples, either alone or together with the X-ray MIX binder, was applied. Sample grinding in an agate mortar was found sufficient to suppress the particle size effect. The optimum pressure was 20 MPa. The optimum geometry was sought for "1"0"9Cd source, and limits of detection of 2.78-0.47 #mu#g were achieved for Cr-Zr elements. Tominaga's method was employed for matrix effect correction. Ti, Fe, Cu, Zn, As, Rb, Sr, Zr and Pb were determined in the SRM's; the relative errors ranged from units per cent (for Zn, Rb, Sr and Zr present in concentrations about 100 ppm and for Fe in concentrations of units per cent) up to 45% (for Ti present in a concentration of 0.67%). The method developed ...

1990-10-01

53

CERES BDS Quality Summaries - Atmospheric Science Data Center - NASA  

Science.gov (United States)

Nov 18, 2010 ... Roughly speaking, the fidelity interval we quote is a "3 sigma" value. ... surface of the foremost quartz filter which is then chemically altered by ... ( CERES) scanner point accuracy using a coastline detection system", ...

54

USGS Water-Quality Information: Fecal Indicator Bacteria  

Science.gov (United States)

USGS - science for a changing world USGS Home Contact USGS Search USGS USGS Water-Quality Information * Home * Data * Methods * Labs * Publications * Topics * Programs * Contact Us...

2011-08-27

55

Quality assurance requirements for packaging, shipping, receiving, storage, and handling of items for water-cooled nuclear power plants (Revision 1) - October 1976  

International Nuclear Information System (INIS)

This guide describes an acceptable method of complying with the Commission's regulations with regard to the quality assurance requirements for the packaging, shipping, receiving, storage, and handling of items for water-cooled nuclear power plants.

56

Quality assurance requirements for installation, inspection, and testing of mechanical equipment and systems  

International Nuclear Information System (INIS)

The guide describes a method acceptable to the NRC staff for complying with the Commission's regulations with regard to quality assurance requirements for installation, inspection, and testing of mechanical equipment and systems for water-cooled and high-temperature gas-cooled nuclear power plants.

57

Impact of an Electronic Medical Record on Diabetes Quality of Care  

UK PubMed Central (United Kingdom)

PURPOSE This study was designed to evaluate the impact of electronic medical record (EMR) implementation on quality of diabetes care.METHODS We conducted a 5-year longitudinal...Full Text Available

2005-07-01

58

Fuzzy theory applied in quality management of distributed manufacturing system: A literature review and classification  

British Library Electronic Table of Contents (United Kingdom)

Fuzzy theory has been regarded as a very important technique for quality management (QM) of distributed manufacturing system and attracts the attentions of academic and industry; however, there is a lack of a comprehensive literature review and a classification scheme for it. This paper is the first academic literature review of the fuzzy theory applied in quality management of distributed manufacturing system. It involves five most popular databases in this research area and covers more than 20 journals, proposes a classification scheme using clustering analysis method. Sixty-one journal articles were finally selected, reviewed and classified. Each selected article was classified firstly based on four QM dimensions (quality planning, quality control, quality assurance and quality improvem...

2011-01-01

59

External quality control for immunocytochemistry on cytology samples: a review of UK NEQAS ICC (cytology module) results  

British Library Electronic Table of Contents (United Kingdom)

I. S. Kirbis, P. Maxwell, M. S. Flear, K. Miller and M. Ibrahim External quality control for immunocytochemistry on cytology samples: a review of UK NEQAS ICC (cytology module) results Objective:- To date, external quality control for immunocytochemistry on cytology samples is provided only by the United Kingdom national external quality assessment service for immunocytochemistry and in situ hybridisation (UK NEQAS ICC & ISH). For the purpose of this study a retrospective analysis of a comprehensive collection of quality-related data regarding immunocytochemistry on cytology samples collected through this service was analysed. Methods:- The quality of immunocytochemical reactions, using on-line collected data, was analysed for the last 23 UK NEQAS ICC cytology module external quality asses...

2011-01-01

60

Diagnostic quality in hysterosalpingography  

International Nuclear Information System (INIS)

Purpose: To compare the diagnostic quality and adverse events of the water-soluble, non-ionic, iso-osmolar, dimeric contrast media iodixanol and iotrolan in hysterosalpingography (HSG). Material and Methods: One hundred and twenty patients participated in a double-blind randomized parallel-group phase-III study. Questionnaires and patient interviews were used. Diagnostic quality was assessed using a visual analogue scale and the quality in specific regions was rated using a categorical scale. Results: Overall diagnostic quality was equal for the two groups. There was no statistically significant difference between the two groups in diagnostic quality in the specific regions of interest. No differences between the contrast media were found with regard to adverse events. Conclusion: Both contrast media provided images of high diagnostic ...

1998-11-01

61

Detection and classification of bearing flaking using kullback discrimination information; Kullback shikibetsu johoryo (KDI) wo mochiita jikuuke no tendomen hakuri no kenchi to shikibetsu  

Energy Technology Data Exchange (ETDEWEB)

Since bearing is in wide use as basic parts for rotary machines, detection and diagnosis of its defects are important in practical use. To discriminate defect portions by early detection of roller bearing flaking, the conventional parameter method using peakedness is poor. Thus to directly obtain difference in waveform, the new method was applied to such detection which uses KDI as the scale of a difference in waveform, and a most neighborhood classification rule based on KDI. The detection and discrimination abilities of this method was studied mainly in experiment. The experiment used a bench scale rotor and a supporting bearing, and attempted detection and discrimination of no flaking, outer ring flaking and inner ring flaking. As a result, this method could detect and ...

1998-06-15

62

High quality water supply system; Joshitsusui kyokyu system  

Energy Technology Data Exchange (ETDEWEB)

This paper, firstly, introduces the background in developing a high quality water supply system, in which the drinking water system is isolated inside a building. Results of questionnaire on the high quality service water are illustrated. The results of questionnaire have revealed that the high quality service water is extremely interested. Then, are described the target quality of high quality water, the constitution of high quality water supply system, the treatment process, the measures to secure safety and sanitary, and the method of maintenance. The high quality water is produced through the activated charcoal absorption treatment, membrane treatment, ozonation, cooling, mineral addition, and disinfection of city water. Furthermore, application examples of this system adopted to a department store and a bachelor ...

1995-01-15

63

The application of the Fuji Computed Radiography system for the diagnosis of pneumoconiosis; Determination of optimum conditions of image processing  

Energy Technology Data Exchange (ETDEWEB)

A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above mentioned image processings are adopted, FCR can be used for the diagnosis of pneumoconiosis with the same ...

1993-06-01

64

The application of the Fuji Computed Radiography system for the diagnosis of pneumoconiosis  

International Nuclear Information System (INIS)

A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above mentioned image processings are adopted, FCR can be used for the diagnosis of pneumoconiosis with the same ...

1993-01-01

65

Quantitative bone scintigraphy in renal osteodystrophy  

International Nuclear Information System (INIS)

The need for noninvasive sensitive techniques for the diagnosis and follow-up of metabolic bone disease in dialysis patients has stimulated the author's interest in the efficacy of more detailed quantitative bone scintigraphy. Using hemodialysis to reduce elevated soft-tissue activity at scintigraphy, an attempt was made to assess the diagnostic sensitivity of quantitative bone scintigraphy as compared to qualitative bone scintigraphic, biochemical, radiographic and bone histologic studies. The second aim of these studies was to determine if one of the two major components of renal osteodystrophy is a major determinant for skeletal radiotracer uptake. The clinical observations on the efficacy and possible specificity of quantitative bone scintigraphy in the diagnosis and follow-up during treatment of renal osteodystrophy are presented briefly in this chapter. Thus, the use of scintigraphy for the routine detection and follow-up of renal osteodystrophy in dialysis ...

66

DOE personnel neutron dosimetry evaluation and upgrade program  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. An Effective Dose ...

1988-10-01

67

Consequences of warm-up of a sector above 80K  

CERN Document Server

There may be circumstances when a sector has to be partially or totally warmed-up to temperatures above 80 K, that is when thermal dilatation starts to play a role. Some equipment have been identify as presenting a risk, like the non-conform "plug-in" modules in the arcs. Because of motion induced by thermal dilatation, the electrical (ElQA) quality control may also have to be done again after cool-down. The main reason identified so far for partial warm-up is the required maintenance of the cooling towers and the cryogenics plants. There is also the request from the vacuum group to periodically warm-up the beam screen to temperatures in the 100 K region to release and pump-out the gas crysorbed on the surface of the beam screen. Observed and expected temperature conditions and statistics on failures of PIMs in sectors which have been warmed-up will be presented in this contribution. Methods to detect buckled PIMs will be ...

2009-01-01

68

Comparison of fluorescence in situ hybridisation using peptide nucleic acid probes, Gram stain/acridine orange leukocyte cytospin and differential time to positivity methods for detection of catheter related bloodstream infection in patients after haematopoietic stem cell transplantation  

British Library Electronic Table of Contents (United Kingdom)

Abstract In 46 febrile neutropenic patients who had undergone haematopoietic stem cell transplantation, the fluorescence in situ hybridisation using peptide nucleic acid probes (PNA FISH), Gram stain/acridine orange leukocyte cytospin (Gram/AOLC), and differential time to positivity (DTP) methods were performed for detection of catheter related bloodstream infections (CRBSIs). As compared with the DTP method (which detected 11 patients with CRBSI), the PNA FISH and the Gram/AOLC methods detected ten of 11 CRBSI patients, resulting in a sensitivity, specificity, negative predictive value and positive predictive value of 91%, 100%, 97% and 100%, respectively, for the PNA FISH method as well as for the Gram/AOLC method.

2010-01-01

69

Coal industry of South Africa  

Energy Technology Data Exchange (ETDEWEB)

This paper discusses geology, coalfields, coal quality, seams and strata, coal reserves, mining methods, production, coal liquefaction, and research on spontaneous combustion and methane explosions.

1980-06-01

70

Quality assurance program requirements (operation)  

International Nuclear Information System (INIS)

Apppendix B of 10 CFR Part 50 establishes quality assurance requirements for the operation of nuclear power plant safety-related structures, systems and components. This Guide describes an acceptable method for complying with these regulations with regard to overall quality assurance program requirements for the operation phase of nuclear power plants. Input to this Guide has been provided by the Advisory Committee on Reactor Safeguards.

71

Quality assurance program requirements (design and construction)  

International Nuclear Information System (INIS)

Appendix B to 10 CFR Part 50 establishes overall quality assurance requirements for the design, construction and operation of safety-related structures, systems, and components. This guide presents a method acceptable to the Commission for complying with these regulations with regard to overall quality assurance program requirements during design and construction of nuclear power plants. Input to this guide has been provided by the Advisory Committee on Reactor Safeguards.

72

Acoustic and visual remote sensing of barrels of radioactive waste: Application of civilian and military technology to environmental management of the oceans  

Energy Technology Data Exchange (ETDEWEB)

As part of an ongoing strategic research project to find barrels of radioactive waste off San Francisco, the U.S. Navy (USN), the U.S. Geological Survey (USGS), and the Gulf of the Farallones National Marine Sanctuary (GFNMS) pooled their expertise, resources, and technology to form a partnership to verify new computer enhancement techniques developed for detecting targets the size of 55 gallon barrels on sidescan sonar images. Between 1946 and 1970, approximately 47,800 large barrels and other containers of radioactive waste were dumped in the ocean west of San Francisco; the containers litter an area of the sea floor of at least 1400 km {sup 2} knows as the Farallon Island Radioactive Waste Dump. The exact location of the containers and the potential hazard the containers pose to the environment is unknown. The USGS developed computer techniques and contracted with private industry to enhance sidescan data, collected in cooperation with the GFNMS, to ...

1995-04-01

73

Rapid Detection of Ophiostoma piceae and O. quercus in Stained Wood by PCR  

UK PubMed Central (United Kingdom)

A rapid, sensitive, and simple method was developed to detect the sapstain fungi Ophiostoma piceae and O. quercus in stained wood. By using microwave heating for DNA...Full Text Available

1999-01-01

74

Immunoquantitative Real-Time PCR for Detection and Quantification of Staphylococcus aureus Enterotoxin B in Foods  

UK PubMed Central (United Kingdom)

A real-time immunoquantitative PCR (iqPCR) method for detection of Staphylococcus aureus enterotoxin B (SEB) was developed and evaluated using both pure cultures and foods. The assay...Full Text Available

2006-10-01

75

Evaluation of Colorimetric Methods Using Nicotinamide for Rapid Detection of Pyrazinamide Resistance in Mycobacterium tuberculosis?  

UK PubMed Central (United Kingdom)

The direct detection of pyrazinamide resistance in Mycobacterium tuberculosis is sufficiently difficult that many laboratories do not attempt it. Most pyrazinamide resistance is caused...Full Text Available

2010-08-01

76

Enzyme amplified immunoassay: a novel technique applied to direct detection of Chlamydia trachomatis in clinical specimens.  

UK PubMed Central (United Kingdom)

Endocervical swabs from 212 women and urethral swabs from 100 men were tested by the routine methods for McCoy cell culture and simultaneously by a novel enzyme amplified immunoassay test to detect...Full Text Available

1985-10-01

77

Diarrheal Illness Detected Through Syndromic Surveillance After a Massive Power Outage: New York City, August 2003  

UK PubMed Central (United Kingdom)

Objectives. We investigated increases in diarrheal illness detected through syndromic surveillance after a power outage in New York City on August 14, 2003.Methods....Full Text Available

2006-03-01

78

Detection of cellular responses to toxicants by dielectrophoresis  

UK PubMed Central (United Kingdom)

The dielectrophoretic (DEP) crossover method has been applied to the detection of cell responses to toxicants. Time and dose responses of the human cultured leukemia (HL-60) line were measured...Full Text Available

2002-08-31

79

Cavity detection by the electric method: the 3-dimensional case  

Energy Technology Data Exchange (ETDEWEB)

In this paper the authors prove a uniqueness theorem for the electric detection of cavities in a three dimensional solid from Cauchy data measured on the surface. The cavities, finite in number, are assumed to be insulating. The surfaces of the cavities are assumed to be smooth on the complement of a set that is, in some sense, negligible. (orig.)

2004-02-01

80

A faster pedigree-based generalized multifactor dimensionality reduction method for detecting gene-gene interactions  

UK PubMed Central (United Kingdom)

We proposed a faster pedigree-based generalized multifactor dimensionality reduction algorithm, called PedG-MDR II (PII), to detect gene-gene interactions underlying complex traits. Inherited...Full Text Available

2011-01-01

81

Imaging-based dust sensors: equipment and methods  

Science.gov (United States)

Dust detection and control in real time, represent one of the most challenging problem in all those environments where fine and ultrafine airborne particulate solids products are present. The presence of such products can be linked to several factors, often directly related and influenced by the working-production actions performed. Independently from the causes generating dust, airborne contaminants are an occupational problem of increasing interest as they are related to a wide number of diseases. In particular, airborne dusts are well known to be associated with several classical occupational lung diseases, such as the pneumoconiosis, especially at high levels of exposure. Nowadays there is also an increasing interest in other dust related diseases, from the most serious as cancer and asthma, to those related with allergies or irritation and other illnesses, also occurring at lower levels of exposure. Among the different critical factors influencing health risk ...

2004-05-01

82

Method and device for identifying different species of honeybees  

Energy Technology Data Exchange (ETDEWEB)

A method and device have been provided for distinguishing Africanized honeybees from European honeybees. The method is based on the discovery of a distinct difference in the acoustical signatures of these two species of honeybees in flight. The European honeybee signature has a fundamental power peak in the 210 to 240 Hz range while the Africanized honeybee signature has a fundamental power peak in the 260 to 290 Hz range. The acoustic signal produced by honeybees is analyzed by means of a detecting device to quickly determine the honeybee species through the detection of the presence of frequencies in one of these distinct ranges. The device includes a microphone for acoustical signal detection which feeds the detected signal into a frequency analyzer which is designed to detect the presence of either of the known fundamental wingbeat ...

1989-01-01

83

The detection and characterization of natural fractures using P-wave reflection data, multicomponent VSP, borehole image logs and the in-situ stress field determination  

Energy Technology Data Exchange (ETDEWEB)

The objectives of this project are to detect and characterize fractures in a naturally fractured tight gas reservoir, using surface seismic methods, borehole imaging logs, and in-situ stress field data. Further, the project aims to evaluate the various seismic methods as to their effectiveness in characterizing the fractures, and to formulate the optimum employment of the seismic methods as regards fracture characterization.

1995-04-01

84

Plagiarism Detection in arXiv  

CERN Document Server

We describe a large-scale application of methods for finding plagiarism in research document collections. The methods are applied to a collection of 284,834 documents collected by arXiv.org over a 14 year period, covering a few different research disciplines. The methodology efficiently detects a variety of problematic author behaviors, and heuristics are developed to reduce the number of false positives. The methods are also efficient enough to implement as a real-time submission screen for a collection many times larger.

2007-01-01

85

Ventilation intensity - Influence on the air quality and its calculation method; Die Lueftungsintensitaet - Auswirkung auf die Luftqualitaet und deren Berechnungsmethoden  

Energy Technology Data Exchange (ETDEWEB)

Because of good thermal insulation of advanced energetic buildings and their good airtightness the air hygiene is insufficient. A normal ventilation behaviour by window opening consumes too much heating energy. A calculation method is shown taking into account a required air change number, flow rate and indoor air quality as thermal comfort in the rooms occupied by different number of persons. (GL)

2006-07-01

86

Infrared radiation features of coal and rocks under loading  

Energy Technology Data Exchange (ETDEWEB)

Samples of fat coal-E, its roof sandstone-A and blind coal-W from two coal mines in Hebei Province of China were brought to the laboratory to study the features of infrared thermal images and radiation temperature in the course of uni-axial load and uni-axial cycle load. To check the results of infrared remote sensing detection, two other methods, acoustic emission detection and electrical resistance detection were also used. The AGA-782 thermalvision detected change of the temperature field of the samples` surfaces. The study showed that: (1) coal rocks and sandstone in the course of loading have three types of infrared thermal image features and three types of infrared radiation temperature features; (2) infrared detection is comparable with acoustic emission detection and electrical resistance detection. Generally, ...

1998-10-01

87

Diagnosis of occipital condyle fractures; Diagnostik von Frakturen der Okzipitalkondylen  

Energy Technology Data Exchange (ETDEWEB)

Following the conventional X-ray diagnosis of the skull and upper cervical spine, CT proved to be the primary diagnostic method after a skull and brain injury: For all 4 cases we succeeded in detecting the occipital condyle fracture and in determing its size and location by reconstructions (coronal, sagittal, 3-D). In the case of complex occompanying injuries like soft tissue hematomas (cerebral, in the spinal cord, and the soft tissue of the neck) or for the detection of brain stem contusion, MRT had significant advantages. MRT can offer a higher image quality in soft tissue, especially in the spinal cord and the brain. (orig.) [Deutsch] Im Anschluss an die konventionelle Roentgendiagnostik des Schaedels und der Halswirbelsaeule, erwies sich die Computertomographie als primaer einzusetzendes diagnostisches Verfahren, nach erlittenem Schaedel-Hirn-Trauma. In allen Faellen gelang der exakte ...

1995-01-01

88

Colonoscopy  

Medline Plus

... experts agree-- a colonoscopy is the most accurate test to detect the cancer, but because of cost ... method. Dr. Randall Burt: Colonoscopy is the best test. The question is therefore shouldn't everyone, since ...

89

Asymmetric Totally-corrective Boosting for Real-time Object Detection  

CERN Document Server

Real-time object detection is one of the core problems in computer vision. The cascade boosting framework proposed by Viola and Jones has become the standard for this problem. In this framework, the learning goal for each node is asymmetric, which is required to achieve a high detection rate and a moderate false positive rate. We develop new boosting algorithms to address this asymmetric learning problem. We show that our methods explicitly optimize asymmetric loss objectives in a totally corrective fashion. The methods are totally corrective in the sense that the coefficients of all selected weak classifiers are updated at each iteration. In contract, conventional boosting like AdaBoost is stage-wise in that only the current weak classifier's coefficient is updated. At the heart of the totally corrective boosting is the column generation technique. Experiments on face detection ...

2010-01-01

90
91

Limitation of immunohistochemical localization of estrogen receptor  

Energy Technology Data Exchange (ETDEWEB)

Although the radioreceptor method is widely used for estrogen receptor assay in human tissue, it has several limitations and a number of alternative methods are being explored. An immunohistochemical method of estrogen receptor assay using a specific antibody to estradiol has been proposed as a suitable alternative. The present study was designed to evaluate the validity of this method in detecting true estrogen receptors in human tumor tissue. Using radioiodinated antibody to estrogen, we have demonstrated that the estrogen antibody can detect the estrogen when it is bound to 4S type receptor but is unable to bind to estrogen when the hormone is bound to 8S type receptor. Our observations suggest that the immunohistochemical method of detection of intracellular cytosolic receptor for estrogen is not a suitable ...

1986-10-01

92

Coal quality engineering aids purchasing  

Energy Technology Data Exchange (ETDEWEB)

New York State Electric and Gas Co. (NYSEG) has developed a tool called Coal Quality Engineering Analysis (CQEA) to evaluate the cost impacts of coal quality on its power plants. CQEA allows quantification of the effect of coal quality on plant operating costs and has become an important factor in coal purchasing. The article describes the development of the analysis method, including a logic diagram of CQEA relationships. The results of CQEA calculations on the impact of one coal on overall production costs of different units, the impact of different coals on overall production costs of one unit, and production cost vs. coal quality, are presented and discussed. The use of the CQEA system within NYSEG is described.

1987-06-01

93

Supernova Neutrinos Detection On Earth  

CERN Document Server

In this paper, we first discuss the detection of supernova neutrino on Earth. Then we propose a possible method to acquire information about $\\theta_{13}$ smaller than $1.5^\\circ$ by detecting the ratio of the event numbers of different flavor supernova neutrinos. Such an sensitivity cannot yet be achieved by the Daya Bay reactor neutrino experiment.

2009-01-01

94

Detection of Atopobium vaginae in postmenopausal women by cultivation-independent methods warrants further investigation.  

Science.gov (United States)

We sequenced 16S rRNA genes from the vaginal swab contents of a postmenopausal woman with asymptomatic bacterial vaginosis (BV). Sequences from Atopobium vaginae were the most commonly detected. In a survey of 35 other postmenopausal women, this organism was detected in 44% with BV but not in any subjects deemed healthy. PMID:15071062

2004-04-01

95

Detection of intracardiac calcification using Fuji computed radiography  

International Nuclear Information System (INIS)

Fuji Computed Radiography (FCR) was evaluated for detection of intracardiac calcification as compared with conventional radiography in 77 patients. Intracardiac calcification was found in 37 patients (left coronary artery: 31, right coronary artery: 11, valve: 9) on cine-fluorography. The sensitivity for detecting these calcified foci with FCR was higher than conventional screen-film method. Especially, sensitivity for detecting left coronary artery calcification with FCR was significantly higher than conventional method (71 %, 32 %) (p < 0.01), Fine anatomical details of calcification were well shown on FCR. Chest radiography using FCR is of great use for detection of intracardiac calcification. (author).

1986-01-01

96

Oil-filled cable surveillance system using newly developed optical fiber gas sensor  

Energy Technology Data Exchange (ETDEWEB)

A new surveillance system for Oil-Filled cable, which can provide continuous monitoring, using a newly developed optical gas sensor that can detect the concentration of the gas dissolved in the oil with extremely high sensitivity has been developed. It was proved that the degree of deterioration of the insulating oil can be detected by measuring C{sub 2}H{sub 2} and CH{sub 4} by investigating the relation between the degree of deterioration and amount of combustible gas generated. In order to detect extremely small amounts of gas, a new gas detecting method using absorption line of the gas using a frequency modulated technique has been developed. The gas detection ability was also confirmed by examination using a 66 kV of cable and the possibility of detection at an early stage is expected.

1996-04-01

97

Detection of mice lung cancer by neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Thermal neutron beam from the TNRF of JRR-3M was utilized for detection of mice lung cancer in vivo. Both the static and real-time neutron imaging were tried. Very strong thermal neutron beam is necessary to detect lung cancers because small changes are hidden by the very large attenuation of thermal neutron beam by the hydrogens in the tissues. The detection was successfully performed. Especially, the Super Eye of Hamamatsu Photonics contributed very effectively. Bone marrows and cartilages were also shown clearly. If an efficient and compact neutron source will become available in future, this method will grow up as a powerful tool for biomedical application. (author).

1995-11-01

98

Methodology for designing air-quality-monitoring networks. 1. Theoretical aspects  

Energy Technology Data Exchange (ETDEWEB)

An objective methodology is presented for determining the number and disposition of ambient air-quality stations in a monitoring network for the primary purpose of compliance with air-quality standards. The methodology utilizes a data base with real or simulated data from an air quality dispersion model for application with a two-step process for ascertaining the optimal monitoring network. In the first step, the air-quality patterns in the data base are collapsed into a single composite pattern through a figure-of-merit (FOM) concept. The most-desirable locations are ranked and identified using the resultant FOM fields. In the second step the network configuration is determined on the basis of the concept of spheres of influence (SOI) developed from cutoff values of spatial-correlation coefficients between potential monitoring sites and adjacent locations. The minimum number of required stations is ...

1986-01-01

99

Determination of As, Cd, Pb, and Hg in urine using inductively coupled plasma mass spectrometry with the direct injection high efficiency nebulizer  

Energy Technology Data Exchange (ETDEWEB)

The application of the large-bore direct injection high efficiency nebulizer (LB-DIHEN) for the determination of arsenic (As), cadmium (Cd), lead (Pb), and mercury (Hg) in urine by inductively coupled plasma mass spectrometry (ICP-MS) is described. The LB-DIHEN is compared with the standard method using a concentric pneumatic nebulizer and cyclonic spray chamber. In addition to the toxicological significance of As, Cd, Pb, and Hg, these elements represent a cross-section of analytical issues including spectral interferences (e.g., {sup 40}Ar{sup 35}Cl{sup +} on {sup 75}As{sup +} and {sup 98}Mo{sup 16}O{sup +} on {sup 114}Cd{sup +}) and memory effects (Hg). In this study, the low sample consumption of the LB-DIHEN is used to reduce the volume of urine needed for analysis, and to reduce the volume of final diluted sample required for analysis. Eliminating the spray chamber and reducing the dead volume of the nebulizer reduces memory effects, especially for analytes ...

2008-03-15

100

SPIO-enhanced MR angiography for the detection of venous thrombosis in an animal model; SPIO-unterstuetzte MR-Angiographie zur Detektion venoeser Thromben im Tiermodell  

Energy Technology Data Exchange (ETDEWEB)

Purpose: An animal model is used to investigate whether MR angiography combined with super-paramagnetic particles of iron oxide (SPIO) is suitable for detecting thromboses. Methods: 42 rats in groups of 7 each were examined on days 1, 3, 5, 7, 9 and 11, respectively, after mechanical/chemical thrombus induction in a 1.5 Tesla magnet with a FISP sequence (TR/TE/FA 50 ms/6 ms/40 ). Imaging was performed before and up to 90 minutes after intravenous injection of 30 {mu}mol FE/kg BW of the experimental SPIO (hydrodynamic diameter, 34{+-}17 nm LLS; R1 and R2 relaxivity at 0.47 T, 31 and 57 L/(mmol*s)). MIP reconstructions of MR angiographies were submitted to consensus assessment by two examiners using histology as the gold standard. Results: The image quality of MIP reconstructions was rated as good in 38 of 42 cases. With regard to thrombotic vessel occlusion, MR angiography coincided with histology in 17 of 42 cases and ...

1999-03-01

101

Method and apparatus for detecting explosives  

Energy Technology Data Exchange (ETDEWEB)

A method and apparatus is provided for detecting explosives by thermal imaging. The explosive material is subjected to a high energy wave which can be either a sound wave or an electromagnetic wave which will initiate a chemical reaction in the explosive material which chemical reaction will produce heat. The heat is then sensed by a thermal imaging device which will provide a signal to a computing device which will alert a user of the apparatus to the possibility of an explosive device being present.

2011-05-10

102

Comparison of C18-Carboxypropylbetaine and Glass Bead DNA Extraction Methods for Detection of Mycobacterium bovis in Bovine Milk Samples and Analysis of Samples by PCR  

UK PubMed Central (United Kingdom)

The purpose of this prospective study was to compare two different milk preparation methods to assay for the presence of Mycobacterium bovis by PCR. Detection by a C18-carboxypropylbetaine...Full Text Available

1998-08-01

103

Multicriteria analysis of ventilation in summer period  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a multicriteria analysis of ventilation during summertime in Europe. Multicriteria analysis theories are used to determine the most suitable ventilation strategy on a university building, that is to say to ensure the best possible indoor air quality, thermal comfort of the occupants and the lower energy consumption in case of accelerated diurnal or nocturnal ventilation and/or air conditioning. After defining the possible actions, the criteria of quality regarding thermal comfort, indoor air quality and energy consumption are defined. The possible actions are then assessed relative to each of these three criteria and ranked from the best to the worst ones using two different multicriteria analysis methods. (author)

2002-02-01

104

Methodological Quality of Studies on the Measurement Properties of Neck Pain and Disability Questionnaires: A Systematic Review  

British Library Electronic Table of Contents (United Kingdom)

Objective: The aim of this study was to obtain an overview of the methodological quality of studies on the measurement properties of neck pain and disability questionnaires and to describe how well various aspects of the design and statistical analyses of studies on measurement properties are performed. Methods: A systematic review was performed of published studies on the measurement properties of neck pain and disability questionnaires. Two reviewers independently rated the quality of the studies using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. This checklist was developed in an international Delphi consensus study. Results: A total of 47 articles were included on the measurement properties of 8 different questionnaires. The meth...

2011-01-01

105

Hybrid ventilation. Control strategies for hybrid ventilation, consequences for air quality, thermal comfort and energy use; Hybrid ventilasjon  

Energy Technology Data Exchange (ETDEWEB)

This article deals with the need for control strategies and control systems in buildings with hybrid ventilation. In this respect, control strategies are methods of keeping certain parameters like temperature, air quality etc within specified limits. A control system is automatic and includes sensors, motors, dampers etc. The article also discusses consequences with respect to thermal comfort, air quality and energy use following selection of control parameters for controlling air masses.

2001-07-01

106

A multi-marker model for detecting chromosomal segments displaying QTL activity  

Science.gov (United States)

A statistical method is presented for detecting quantitative trait loci (QTLs), based on the linear model. Unlike methods able to detect a few well separated QTLs and to estimate their effects and positions, this method considers the genome as a whole and enables the detection of chromosomal segments involved in the differences between two homozygous lines, and their backcross, doubled haploid, or F[sub 2] progenies, for a quantitative trait. Genetic markers must be codominant, but missing markers are accepted, provided they are missing independently from the experiment. Asymptotic properties, which are of practical use, are developed. This method does not rely on strong genetic hypotheses, and thus does not permit any precise genetic analysis of the trait under study, but it does assess which regions of the genome are involved, whatever the ...

1993-08-01

107

Programmable radionuclide X-ray fluorescence multi-channel spectrometric analyzer, type 123-1  

International Nuclear Information System (INIS)

The whole equipment consists of three separate portable parts: a detector case, a microprocessor and a graphic TV monitor. Magnetic tape memory and an x-y recorder can be connected for recording the measured spectra. The analyzer contains two built-in exchangeable excitation radionuclides. Fluorescence and scattered radiation is detected using a proportional detector. The detected pulses are analyzed by a 256-channel analyzer and the results are shown on the display. The device may be used in mining laboratories, coal and ore dressing plant control rooms or in mining fields of open cast mines for quick detection of the quality of mined or dressed raw materials. (E.S.). 1 fig.

1988-01-01

108

Quality engineering and control. Annual progress report, January-December 1981  

International Nuclear Information System (INIS)

Brief summaries are given of research carried out in the following areas: absorption spectroscopy of titanium, niobium, and molybdenum in uranium alloys; atomic absorption spectroscopy of selenium in stainless steel, computer program improvements for spectrophotometer control, and detection of beryllium in stack gases; electrolysis for inactivation of bacteria in cooling-tower water; improved solvent analysis by gas chromatography; sequential radionuclide separation for various sample matrices; progress on an electron microprobe analyzer; and miscellaneous projects.

109

The influence of stray radiation on image quality  

International Nuclear Information System (INIS)

The present state of knowledge on the influence of stray radiation on image quality and its physical description and quantification is summarized. Experimental results on the influence of physical parameters on the fraction of scattered radiation and the effect of scatter reduction by air gap technique and secondary radiation grids are committed. Open theoretical and practical problems and the limitations of common methods of scatter reduction are pointed out. (author).

110

Power cables: methods of defects localization; Cables d'energie: methodes de localisation des defauts  

Energy Technology Data Exchange (ETDEWEB)

The defects localization in power cables follows several steps: identification, pre-localization and precise localization. Pre-localization methods, other than echo-metry, are presented first: bridge methods, particular case of low voltage networks, future perspectives. Then, the precise localization methods are described: magneto-acoustic method, audible frequencies method. The particular case of underwater and high-voltage cables is considered too (oil and gas leaks detection). (J.S.)

2006-08-15

111

Experimental studies on a structure of eddy current probe for detection of magnetic flux disturbed by a flaw  

International Nuclear Information System (INIS)

Bobbin-coil-type eddy current probes, which are conventionally used for nondestructive inspection of steam generator tubes in pressurized-water-type nuclear power plants, have poor detectability for circumferential flaws. Hence a new type of eddy current probe was proposed to detect effectively the magnetic flux component disturbed by a flaw and thus to eliminate the flaw direction dependency on the flaw detectability. In the course of development of the proposed method, structures of the probe were investigated based on the measurement of magnetic fields induced by exciting flat coils with several shapes. The new type of probe proposed here consists of differential pick-up coils detecting magnetic flux and exciting coils having a parallelogrammic shape, and its structure was fabricated experimentally in order to detect flaws independently of their directions. ...

1995-01-01

112

An effective method to estimate multidimensional Gaussian states  

CERN Document Server

A simple and efficient method for characterization of multidimensional Gaussian states is suggested and experimentally demonstrated. Our scheme shows analogies with tomography of finite dimensional quantum states, with the covariance matrix playing the role of the density matrix and homodyne detection providing Stern-Gerlach-like projections. The major difference stems from a different character of relevant noises: while the statistics of Stern-Gerlach-like measurements is governed by binomial statistics, the detection of quadrature variances correspond to chi-square statistics. For Gaussian and near Gaussian states the suggested method provides, compared to standard tomography techniques, more stable and reliable reconstructions. In addition, by putting together reconstruction methods for Gaussian and arbitrary states, we obtain a tool to detect the ...

2009-01-01

113

Groundwater quality assessment plan for single-shell tank waste management Area U at the Hanford Site  

Energy Technology Data Exchange (ETDEWEB)

Waste Management Area U (WMA U) includes the U Tank Farm, is currently regulated under RCRA interim-status regulations, and is scheduled for closure probably post-2030. Groundwater monitoring has been under an evaluation program that compared general contaminant indicator parameters from downgradient wells to background values established from upgradient wells. One of the indicator parameters, specific conductance, exceeded its background value in one downgradient well triggering a change from detection monitoring to a groundwater quality assessment program. The objective of the first phase of this assessment program is to determine whether the increased concentrations of nitrate and chromium in groundwater are from WMA U or from an upgradient source. Based on the results of the first determination, if WMA U is not the source of contamination, then the site will revert to detection monitoring. If WMA U is the source, then a ...

2000-03-21

114

Fuel injection control for diesel engine  

Energy Technology Data Exchange (ETDEWEB)

A method is described for controlling fuel injection in a diesel engine having a fuel injection nozzle, comprising the steps of: detecting an idling state of the diesel engine and pressure in a combustion chamber; obtaining a pressure increment rate from the pressure detected by the detecting step; selecting a valve opening pressure of the fuel injection nozzle at a relatively low level when the idling state is detected by the detecting step, thereby setting a two peaks characteristics of a fuel injection rate; and controlling the fuel injection nozzle in response to the pressure increment rate so that the pressure increment rate in the combustion chamber is maintained within a predetermined value by changing a fuel injection quantity of a pilot injection from the fuel injection nozzle.

1987-11-10

115

Traumatic and Non-traumatic Fibromyalgia Syndrome: Impact Assessment on the Life Quality of Women  

British Library Electronic Table of Contents (United Kingdom)

Objective To investigate the impact on life quality of women with traumatic and non-traumatic origin fibromyalgia syndrome [FMS]. Method Women affected with FMS were selected and divided into two groups: those with traumatic origin FMS [Group 1] and those with non-traumatic origin FMS [Group 2]. A standard question form was used for the research, as well as the fibromyalgia impact questionnaire [FIQ] for evaluation of life quality. Results Seventy-two patients, 34 for Group 1 and 38 for Group 2 were analyzed. The main triggering symptoms were divorce [23.5 percent of cases] and death in the family [23.5 percent of cases]. In addition to diffuse pain, the main symptoms presented were poor sleep quality, weariness, and paresthesia, with no difference between the groups; migraine had a greate...

2011-01-01

116

Determinants of software quality in offshore development - An empirical study of an Indian vendor  

British Library Electronic Table of Contents (United Kingdom)

ContextCost advantage has been one of the primary drivers of successful offshoring engagements of Indian software and services companies. However, the emphasis has shifted to the ability of the vendors to provide high quality over cost advantage in delivering software products and services. Meeting high quality requirements of the clients is a challenge due to the very nature of development and delivery of software through offshoring. ObjectiveThe objective of this research paper is to identify and evaluate the key determinants of quality in the case of software projects delivered through offshoring model. MethodA detailed survey was conducted among project managers/project leaders (leads) of a leading midsize Indian IT services company to evaluate the relationship of the determinants on t...

2011-01-01

117

Bilateral but not Unilateral Testicular Hypotrophy Predicts for Severe Impairment of Semen Quality in Men with Varicocele Undergoing Infertility Evaluation  

British Library Electronic Table of Contents (United Kingdom)

ObjectivesVaricocele is a common cause of infertility, and varicocele-associated testicular hypotrophy has been described as a potential cause of decreased semen quality. We investigated the relationship between testicular hypotrophy and poor semen quality in infertile men with varicoceles. We hypothesized that bilateral hypotrophy is required before the semen quality is severely impaired.MethodsWe retrospectively identified consecutive patients with palpable varicoceles undergoing an infertility evaluation at a single academic center. Each patient was evaluated by the same clinician with history and physical examination. Testicular hypotrophy was defined as a size discrepancy of greater than 3 mL or an absolute size of less than 14 mL. Multivariate logistic regression analysis was used to...

2008-01-01

118

Development of radioimmunometric assays and kits for non-clinical applications. Proceedings of a final research coordination meeting  

International Nuclear Information System (INIS)

Immunoassays are versatile analytical techniques that had a leading role in various clinical applications, during the last four decades. The studies carried out by Rosalyn Yalow, Solomon Berson and Roger Ekins in the 1960s gave a breakthrough in the development of this novel analytical method. Sensitivity up to femtomolar concentrations, high specificity and universal application to different classes of molecular species made immunoassay a very useful tool in analytical investigation. The expertise acquired by immunochemists in producing antibodies against any antigen and the ability of radiochemists in labeling the antigens with "1"2"5I without affecting the active site are the two main factors responsible for the above development. There are concerns about the safety and health of humans due to the high-level contamination of environment by pesticides, industrial compounds and metals, anabolic steroids in milk and meat products, and presence of mycotoxins in food ...

2004-12-06

119

Simultaneous ultraviolet spectrophotometric determination of nitrate and nitrite in water  

Energy Technology Data Exchange (ETDEWEB)

A rapid and accurate method for the direct simultaneous determination of nitrate and nitrite is proposed. The method is applied to the determination of nitrate and nitrite in rainwater and wastewater without preliminary separation. The determinations are performed by a CPA matrix method with ultraviolet spectrophotometric detection. The results obtained are in agreement with those obtained by conventional methods for the determination of nitrate and nitrite.

1991-02-01

120

Determination of lead in biological and environmental samples by "2"0"3Pb isotope dilution substoichiometric method  

International Nuclear Information System (INIS)

A procedure for the determination of lead in various biological and environmental samples by "2"0"3Pb radioisotope dilution substoichiometric method is presented. The accuracy of the method by comparison with the literature values of reference materials appears to be good. The standard deviation of the method is less than 10%, and detection limit is about 0.1 #mu#g of lead. (author) 5 refs.

121

Quality control in laboratory investigations on Schistosoma mansoni on St Lucia, West Indies: a staff assessment scheme*  

UK PubMed Central (United Kingdom)

A method is described for the supervision of technicians engaged in microscopical screening of large numbers of stools for Schistosoma mansoni ova. The scheme presents graphically...Full Text Available

1978-01-01

122

Noise suppression in scatter correction for cone-beam CT  

UK PubMed Central (United Kingdom)

Scatter correction is crucial to the quality of reconstructed images in x-ray cone-beam computed tomography (CBCT). Most of existing scatter correction methods assume smooth scatter distributions. The...Full Text Available

2009-03-01

123

Exercise training for systolic heart failure: Cochrane systematic review and meta-analysis  

UK PubMed Central (United Kingdom)

AimsTo determine the effect of exercise training on clinical events and health-related quality of life (HRQoL) of patients with systolic heart failure.Methods...Full Text Available

2010-07-01

124

Determining insoluble impurities in spent sulfuric acid from the production of synthetic alcohols  

Energy Technology Data Exchange (ETDEWEB)

Ammonium sulfate is produced from spent sulfuric acid from the production of alcohols. Certain mineral and organic impurities exist in the sulfuric acid that impair the quality of the ammonium sulfate. A detailed method for the chemical analysis for the impurities is presented.

1983-01-01

125

Design of the Endobronchial Valve for Emphysema Palliation Trial (VENT): a non-surgical method of lung volume reduction  

UK PubMed Central (United Kingdom)

BackgroundLung volume reduction surgery is effective at improving lung function, quality of life, and mortality in carefully selected individuals with advanced emphysema. Recently,...Full Text Available

126

Adapting developing country epidemiological assessment techniques to improve the quality of health needs assessments in developed countries  

UK PubMed Central (United Kingdom)

BackgroundWe were commissioned to carry out three health assessments in urban areas of Dublin in Ireland. We required an epidemiologically robust method that could collect data rapidly...Full Text Available

127

How does one develop the right quality assurance program for waste management projects?  

International Nuclear Information System (INIS)

The quality assurance requirements in use today for radioactive waste facilities, geologic repositories and hazardous waste projects were developed initially for the nuclear power plant industry, and their intent is being applied by regulations and guidance documents to radioactive and hazardous waste programs. The wording of the NRC quality assurance requirements in Appendix B of 10CFR50, the related guidance documents and the industry's ANSI/ASME NQA-1 were developed over a period of several years to address quality assurance for the design and construction of the complex and interactive systems to produce electrical power using nuclear fuel. Now, those same documents are the basis for the quality assurance requirements and guidance for waste management facilities and repositories. The intent of Appendix B of 10CFR50 and NQA-1 can easily be applied to waste projects, providing one understands and uses ...

1988-10-03

128

Method and system for detecting explosives  

Energy Technology Data Exchange (ETDEWEB)

A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

2009-03-10

129

Explosives detection system and method  

Energy Technology Data Exchange (ETDEWEB)

A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

2007-12-11

130

Application of wavelet analysis to signal processing methods for eddy-current test; ueburetto kaiseki no kadenryushinshoho heno tekiyo  

Energy Technology Data Exchange (ETDEWEB)

This study deals with the application of wavelet analysis to detection and characterization of defects from eddy-current and ultrasonic testing signals of a low signal-to-noise ratio. Presented in this paper are the methods for processing eddy-current testing signals of heat exchanger tubes of a steam generator in a nuclear power plant. The results of processing eddy-current testing signals of tube test pieces with artificial flaws show that the flaw signals corrupted by noise and/or non-defect signals can be effectively detected and characterized by using the wavelet methods. (author)

1998-12-15

131

A quantitative method to detect explosives and selected semivolatiles in soil samples by Fourier transform infrared spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a novel Fourier transform infrared (FTIR) spectroscopic method that can be used to rapidly screen soil samples from potentially hazardous waste sites. Samples are heated in a thermal desorption unit and the resultant vapors are collected and analyzed in a long-path gas cell mounted in a FTIR. Laboratory analysis of a soil sample by FTIR takes approximately 10 minutes. This method has been developed to identify and quantify microgram concentrations of explosives in soil samples and is directly applicable to the detection of selected volatile organics, semivolatile organics, and pesticides.

1995-06-01

132

Use of the acoustic method for checking the quality of concrete of hydroelectric and pumped storage stations  

Energy Technology Data Exchange (ETDEWEB)

This article describes acoustic methods used in the in-service inspection of the dams and peripheral concrete structures of the Toktogul, Kurpsai, and Bratsk hydroelectric and pumped storage plants. The tests were conducted to assess the compression strength, elasticity, and tensile strength of the concretes. Comparative evaluations against drill core studies proved the acoustic methods to be sufficiently accurate in predicting aging behavior and loss of mechanical and physical integrity in the concretes.

1987-09-01

133

Effects of sediment quality on macroinvertebrates in the Sunraysia region of the Murray-Darling Rivers, Australia  

International Nuclear Information System (INIS)

A field-based microcosm approach was tested to identify deterioration of sediment quality in waterways using freshwater macroinvertebrates. The method can potentially identify the nature of contaminants based on species-specific responses. Sediments were collected from the Murray and Darling Rivers and irrigation drains within the Sunraysia region of south-eastern Australia and compared to non-polluted reference sediment. Clean sediments were also spiked with fertiliser to test whether nutrients affected the aquatic fauna. Seven of the eight sediments from the Sunraysia region had a negative impact on the macroinvertebrates, in particular sediment from the Darling River, which supported an impoverished fauna. Three species of chironomid showed varied responses to sediment quality and, although it was hypothesised that nutrients may have impacted on the macroinvertebrate fauna, the results suggest that other pollutants are ...

2008-12-01

134

Assessment of the effects of pixel loss on image quality in direct digital radiography  

Energy Technology Data Exchange (ETDEWEB)

Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. ...

2004-03-21

135

Assessment of the effects of pixel loss on image quality in direct digital radiography  

International Nuclear Information System (INIS)

Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. Measurement of the MTF, NPS and DQE can ...

2004-03-21

136

Use of a point-of-care beta-hydroxybutyrate sensor for detection of ketonemia in dogs.  

Science.gov (United States)

The urine test strip is the most common test used to detect ketones in veterinary patients, but it can underestimate the degree of ketonuria and hence, ketonemia. Additionally, adequate urine samples for analysis may be difficult to obtain from dehydrated animals. The standard method used to detect and monitor ketonemia in human medicine is measurement of serum or whole blood beta-hydroxybutyrate (?HOB). A point-of-care (POC) analyzer has been validated for this purpose in humans. This study compared the accuracy of the POC device to an enzymatic reaction laboratory method for measurement of ?HOB in dogs. Although the POC sensor tended to overestimate ?HOB concentrations, there was good correlation (R(2) = 0.96) and good agreement between the 2 methods with a bias +/- precision of 0.0860 +/- 0.3410 mmol/L ?HOB. The POC ?HOB sensor can be useful for assessing ketonemia in dogs. ...

2010-09-01

137

Liquid chromatography with ultraviolet and dual parallel mass spectrometric detection for analysis of vitamin D in retail fortified orange juice  

British Library Electronic Table of Contents (United Kingdom)

Samples of vitamin D fortified orange juice obtained from retail food stores were analyzed for vitamin D3 content using a method developed by combining the best features of two AOAC methods. Detection by ultraviolet absorption at 265nm was compared to detection by selected ion monitoring (SIM) using atmospheric pressure chemical ionization (APCI) mass spectrometry (MS). Furthermore, an ion trap (IT) mass spectrometer was employed in a 'dual parallel MS' arrangement to simultaneously obtain qualitative APCI-ITMS data. The method was applied to 33 samples of 3 national American orange juice brands and 7 samples of 5 other American brands collected using a statistically designed sampling plan as part of the National Food and Nutrient Analysis Program to provide values for the USDA National Nu...

2011-01-01

138

Hybrid Camera Surveillance System Using Robust Human Detection  

Science.gov (United States)

We propose a novel surveillance system that uses hybrid camera network. The system contains a panorama camera and PTZ cameras to take the wide range images and face images at high enough resolution for identification tasks. The robust human detection methods include robust background subtraction method (RRC), skin color segmentation and face tracking method. First, the system detects persons from a panorama image, and then the detailed face images are obtained with the PTZ cameras. The PTZ cameras can track the faces using the four directional features and the relaxation matching. In addition, the system has automatic camera position calibration feature. Thus, the user can use the system without any troublesome settings.

2007-01-01

139

Electrochemical noise in corrosion  

International Nuclear Information System (INIS)

By varying different variables (potential, chloride content, surface pretreatment etc.) it is possible to show the effect of increasingly harsher corrosion conditions on passive-layer stability. These changes will not be detected by conventional methods e.g. measurement of passive current density, until a very late stage. Electrochemical noise measurement will allow the action of inhibitors to be detected in a rapid and effective manner. High-alloy steels and titanium claddings subjected to pitting corrosion in chloride-containing media demonstrate how to use this method for problem solutions and to open up new practical applications. The effect of mechanical stresses (natural, tensile) on the corrosion system can be detected by electrochemical noise which opens up new methods for crack corrosion studying and monitoring. (orig./DG).

1993-10-07

140

Three-dimensional rotational angiography of the carotid arteries with high-flow injection from the aortic arch. Preliminary experience  

International Nuclear Information System (INIS)

Purpose: Three-dimensional rotational angiography (3DRA) is a new technique based on a rotational angiographic acquisition able to display arterial vessels in a 3D rendering mode. The system was mainly developed for neuroradiological evaluations but preliminary extracranial experiences have also been reported. The aim of our work was to compare the results of three-dimensional angiography of the carotid arteries done with high-flow injection of contrast medium from the aortic arch with the results of selective angiography. Materials and methods: Twenty patients underwent digital angiography of the supra-aortic vessels in order to quantify a stenosis of the carotid bifurcations previously detected at Doppler Ultrasound. Examinations were performed with the Philips Integris Allura system provided with the rotational angiography (RA) tool connected to a workstation for three-dimensional reconstruction able to display vessels in a 3D fashion ...

141

Optically stimulated luminescence and thermoluminescence in CVD diamond and dosimetric evaluation in fields of ionizing radiation; Luminiscencia opticamente estimulada y termoluminiscencia en diamante DQV y evaluacion dosimetrica en campos de radiacion ionizante  

Energy Technology Data Exchange (ETDEWEB)

The optically stimulated luminescence (OSL) results a highly appropriate dosimetric technique for readings of absorbed radiation 'in alive' and 'in situ', as well as in real time. The CVD diamond on the other hand presents excellent qualities like radiation reader thanks to its reproducibility, radiation resistance, biocompatibility and non toxicity. The present work studies the answer of two diamond films pure and polluted with nitrogen (750 ppm) grown by the Chemical Vapor Deposition method (CVD) on silicon substrate (001) irradiated with beta (Sr-90) in the 0.833-100 Gy interval. The optical stimulation was carried out by 40 seconds with infrared laser (830 nm, 0.36 W/cm{sup 2}) and the filter BG-39 (300-600 nm) coupled the PM. The intensity and the decay of the hyperbolic type of the LOE curves were similar in both samples, for the non doped diamond were observed trapping states in 200-380 C being ...

2006-07-01

142

Configurable Middleware-Level Intrusion Detection for Embedded Systems  

Energy Technology Data Exchange (ETDEWEB)

Embedded systems have become integral parts of a diverse range of systems from automobiles to critical infrastructure applications such as gas and electric power distribution. Unfortunately, research on computer security in general and intrusion detection in particular, has not kept pace. Furthermore, embedded systems, by their very nature, are application specific and therefore frameworks for developing application-specific intrusion detection systems for distributed embedded systems must be researched, designed, and implemented. In this paper, we present a configurable middleware-based intrusion detection framework. In particular, this paper presents a system model and a concrete implementation of a highly configurable intrusion detection framework that is integrated into MicroQoSCORBA, a highly configurable middleware framework developed for embedded systems. By exploiting the application-specific ...

2005-06-20

143

MRT versus CT in the diagnosis of pneumonia. Evaluation of a T{sub 2}-weighted utrafast turbo-spin-echo sequence (UTSE); MRT versus CT in der Diagnostik von Pneumonien. Evaluation einer T{sub 2}-gewichteten ultraschnellen Turbo-Spin-Echo-Sequenz (UTSE)  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate a T{sub 2}-weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T{sub 2}-weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR{sub eff}/T{sub E}/Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis and representation of the lesions, in 25% MRT was superior. MRT was better for the ...

1999-05-01

144

Combined inverse modeling approach and load duration curve method for variable nitrogen total maximum daily load development in an agricultural watershed  

British Library Electronic Table of Contents (United Kingdom)

Purpose Nonpoint sources (NPS) pollution has been an important cause for water quality impairment worldwide. To take the temporal variations of both NPS pollution and in-stream attenuation into consideration, an inverse modeling approach and the load duration curve (LDC) method were combined for variable nutrient total maximum daily load (TMDL) development. Methods Water quality and hydrological parameters were monitored monthly along the ChangLe River system in 2004?2008. The catchment NPS export load (EL) and TMDL for total nitrogen (TN) were estimated by the inverse format of an existing stream nutrient transport equation. The LDC method was used to describe the variability of EL, TMDL, requiring load (RLR) and percent (the ratio between the RLR and the EL, RPR) reduction, and then to s...

2011-01-01

145

Boring of full scale deposition holes using a novel dry blind boring method  

Energy Technology Data Exchange (ETDEWEB)

Three holes the size of deposition holes (depth 7.5 m and diameter 1.5 m) were bored in the Research Tunnel at Olkiluoto, Finland. A novel full-face boring technique was used based on rotary crushing of rock and removal of crushed rock by vacuum flushing through the drill string. The purpose of the work was to demonstrate the feasibility of the technique. During the boring test procedures were carried out in order to determine the effect of changes in operating parameters on the performance of the boring machine and the quality of the hole. The boring method was found to be technically feasible and efficient. Evaluation of the quality of the hole included studies of the geometry of the hole, measurements of the surface roughness using a laser profilometer and study of excavation disturbances in the zone adjacent to the surface of the holes using two novel methods, He-gas diffusion and the {sup ...

1996-10-01

146

Microcantilever detector for explosives  

Energy Technology Data Exchange (ETDEWEB)

Methods and apparatus for detecting the presence of explosives by analyzing a vapor sample from the suspect vicinity utilize at least one microcantilever. Explosive gas molecules which have been adsorbed onto the microcantilever are subsequently heated to cause combustion. Heat, along with momentum transfer from combustion, causes bending and a transient resonance response of the microcantilever which may be detected by a laser diode which is focused on the microcantilever and a photodetector which detects deflection of the reflected laser beam caused by heat-induced deflection and resonance response of the microcantilever. 2 figs.

1999-06-29

147

A high-sensitivity scintillation chamber for radon in gas  

Energy Technology Data Exchange (ETDEWEB)

A large scintillation chamber of 6.7 l volume for direct radon concentration measurements in gas is presented. With two 5 in. photomultipliers on opposite sides, working in coincidence, a concentration as low as about 0.5 mBq/l is detectable with 10% standard deviation after 1000 min measuring time. With the achieved background count rate of 0.42 counts/min and the counting efficiency of 0.607 for [sup 222]Rn and its progenies the absolute minimal detectable specific activity is reached with 0.17 mBq/l at about 12 000 min. The method to determine this minimum detectable activity is outlined. ((orig.))

1994-06-15

148

Improvement of detectability for circumferential crack of Steam Generator tube by eddy current and ultrasonic testing method  

International Nuclear Information System (INIS)

Steam Generator (SG) tubes in PWR plant are periodically inspected using eddy current testing (ECT) method. In Japan, bobbin coil type dual function probe is used for full length inspection, but the detectability for circumferential crack is very poor, and to improve detectability for circumferential crack and supplement regular ECT, various kinds of multi segment eddy current probes and multi transducer ultrasonic testing (UT) method have been developed. ECT probes are constructed of multiple surfaceriding special winding differential type coils and UT probe consists of 16 transducers which are spaced equally around the probe circumference for 360deg wall coverage. Both of those EC and UT probes are designed effective to detect circumferential crack. On the other hand, various kinds of laboratory induced circumferential cracks have been made and destroyed to prove the ...

1991-08-01

149

Geometrically anisotropic probes: an improved eddy current technique  

Energy Technology Data Exchange (ETDEWEB)

Geometrically anisotropic eddy current probes are a type of separate function probes especially fit to the detection of defects showing a preferential direction. This kind of flaw induces a coupling between the transmitter and the receiver by guiding eddy currents from the one to the other. On the other hand, this coupling will be almost non-existent in the presence of defects or spurious effects not displaying this geometrical particularity. Basic studies on an elementary two-coil set-up allow the acknowledgment of the intrinsic qualities of such probes: good signal-to-noise ratio, influence field practically constant on the whole defect length, ability to detect bridged defects, insensitivity to lift off. These results can be improved by achieving multicoils probes adapted to different kinds of problems. An application to continuous casting slabs testing yields very interesting results in the ...

1987-06-01

150

Study of cosmic ray nuclei detection by an image calorimeter  

Energy Technology Data Exchange (ETDEWEB)

It is shown that a cosmic gamma-ray telescope made of a multilayer silicon tracker and a imaging CsI calorimeter, is capable of identifying cosmic ray nuclei. The telescope charge resolution is estimated around 4% independently of charge. Simulation methods are used to determine the telescope properties for nuclei detection.

1995-09-01

151

Radiation treatment of crude drugs. Development of suitable methods of detection. Strahlenbehandlung von Arzneidrogen. Entwicklung geeigneter Nachweismethoden  

Energy Technology Data Exchange (ETDEWEB)

It may be necessary to reduce microbiological contamination of crude drugs (medicinal plants or their parts like roots, leaves, flowers). This can be done by treating the drugs with ionizing radiation. Meethods for detection of such an irradiation were developed. It could be pointed out that measurements of luminescence, viscosity and electron spin resonance were suitable for specific drugs, but not for all drugs. (orig.).

1992-09-01

152

Evaluation of the Bactec MGIT 960 system in combination with the MGIT TBc identification test for detection of Mycobacterium tuberculosis complex in respiratory specimens.  

Science.gov (United States)

The sensitivity and specificity of the MGIT TBc identification (TBc ID) test for Mycobacterium tuberculosis complex (MTC) detection in positive Bactec MGIT cultures were 95.2% and 99.2%, respectively. When MTC-positive results obtained from two additional molecular methods were included, the sensitivity of the MGIT TBc ID test was 85.4%, while that of culture was 95.7%. PMID:21450949

2011-03-30

153

Detection of aortoarterial graft infections by leukocyte scintigraphy  

Energy Technology Data Exchange (ETDEWEB)

Infections of aortoarterial prostheses are serious, difficult to detect, and difficult to treat. Scintigraphy with indium-111 labeled autologous leukocytes is an accurate noninvasive method of assessing the presence and extent of such an infection. In three cases of aorto-arterial bypass graft infections, the leukocyte study was successful in establishing the diagnosis and in assessing the extent of infection. Other noninvasive diagnostic techniques are useful, but all have serious limitations. The leukocyte study alone appears to be free of likely sources of error.

1983-09-01

154

A rapid and simple DNA extraction procedure to detect Salmonella spp. and Listeria monocytogenes from fresh produce using real-time PCR  

Science.gov (United States)

DNA isolation procedures significantly influence the outcome of PCR-based detection of human pathogens. Unlike clinical samples, DNA isolation from food samples such as fresh and fresh-cut produce has remained a formidable task and has hampered the sensitivity and accuracy of molecular methods. We...

155

Preparatory Signal Detection for Annex I Countries under the Kyoto Protocol. A Lesson for the Post-Kyoto Policy Process  

Energy Technology Data Exchange (ETDEWEB)

The focus of this study is on the preparatory detection of uncertain net greenhouse gas (GHG) emission changes (also termed emission signals) under the Kyoto Protocol. The crucial question to be addressed is: How well do we need to know net emissions if we want to detect a specified emission signal after a given time? No restrictions exist as to what concerns the net emitter, which may be any GHG source or sink. Annex I countries are chosen as net emitters, simply for reasons of data availability and because of the excellent possibility of comparing net emitters (inter-country comparison). The countries' emissions - in an increasing number of cases even their uncertainties - are available permitting the application of preparatory signal detection techniques, which are suited to address the aforementioned question. We currently discuss four hierarchically-ordered detection concepts to assess ...

2004-06-14

156

Reduction of fluoroscopic exposure for the air-contrast barium enema  

Energy Technology Data Exchange (ETDEWEB)

In a fluoroscopic imaging system, image quality and patient dose are both affected by the optical system linking the image intensifier with the video camera. The effect on patient exposure of increasing the optical iris aperture size over that required for other procedures performed on the same imaging system was investigated for the air-contrast barium enema examination. Using a large-area transmission ionisation chamber to monitor the Roentgen-area-product of entrance exposure, a decrease in fluoroscopic radiation of greater than 50% was clinically documented for a fluoroscopic system utilising kVp and mA variable automatic brightness control. For this iris change, the video image was of acceptable quality for positioning and monitoring the patient, and no deleterious effect was detected in the conduct of the air-contrast exam. The availability of a variable-sized operator-selectable iris diaphragm would permit this ...

1983-11-01

157

A facile and green preparation of high-quality CdTe semiconductor nanocrystals at room temperature  

Energy Technology Data Exchange (ETDEWEB)

One chemical reagent, hydrazine hydrate, was discovered to accelerate the growth of semiconductor nanocrystals (cadmium telluride) instead of additional energy, which was applied to the synthesis of high-quality CdTe nanocrystals at room temperature and ambient conditions within several hours. Under this mild condition the mercapto stabilizers were not destroyed, and they guaranteed CdTe nanocrystal particle sizes with narrow and uniform distribution over the largest possible range. The CdTe nanocrystals (photoluminescence emission range of 530-660 nm) synthesized in this way had very good spectral properties; for instance, they showed high photoluminescence quantum yield of up to 60%. Furthermore, we have succeeded in detecting the living Borrelia burgdorferi of Lyme disease by its photoluminescence image using CdTe nanocrystals.

2008-06-18

158

Novel Method for Processing Respiratory Specimens for Detection of Mycobacteria by Using C18-Carboxypropylbetaine: Blinded Study  

UK PubMed Central (United Kingdom)

A novel method for processing respiratory specimens to improve culture and acid-fast staining of mycobacteria is introduced. This new method utilized N,N-dimethyl-N-(n-octadecyl)-N-(3-carboxypropyl)ammonium...Full Text Available

1998-07-01

159

Determination of lead in soil samples by "2"0"3Pb radioisotope dilution substoichiometric method  

International Nuclear Information System (INIS)

A procedure for the determination of lead in soil samples by "2"0"3Pb radioisotope dilution substoichiometric method is described. Japan NIES No.2 river clay standard sample and 83-40 Tibet soil standard sample were determined. The obtained values were in good agreement with reference values. The standard deviation of the method was less then 5%. Detection limit was about 0.1 #mu#g Pb.

160

The Blind NasoTracheal Aspiration Method Is Not a Useful Tool for Pathogen Detection of Pneumonia in Children  

UK PubMed Central (United Kingdom)

BackgroundAcute lower respiratory infection (ALRI) is a major cause of hospitalization for children in China, while the etiological diagnosis of ALRI remains a challenge. This study...Full Text Available

161

Species-specific Fungal DNA in Airborne Dust as Surrogate for Occupational Mycotoxin Exposure?  

UK PubMed Central (United Kingdom)

Possible health risks associated with occupational inhalation of mycotoxin-containing dust remain largely unknown, partly because methods for mycotoxin detection are not sensitive enough for the small...Full Text Available

162

Selective imaging of adherent targeted ultrasound contrast agents  

UK PubMed Central (United Kingdom)

The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available

2007-04-21

163

ProMoST: A tool for calculating the pI and molecular mass of phosphorylated and modified proteins on 2 dimensional gels  

UK PubMed Central (United Kingdom)

Protein modifications such as phosphorylation are often studied by two-dimensional gel electrophoresis since the perturbation in the protein’s pI value is readily detected by this method....Full Text Available

2009-01-01

164

Power of grammatical evolution neural networks to detect gene-gene interactions in the presence of error  

UK PubMed Central (United Kingdom)

BackgroundWith the advent of increasingly efficient means to obtain genetic information, a great insurgence of data has resulted, leading to the need for methods for analyzing this...Full Text Available

165

LED Arrays as Cost Effective and Efficient Light Sources for Widefield Microscopy  

UK PubMed Central (United Kingdom)

New developments in fluorophores as well as in detection methods have fueled the rapid growth of optical imaging in the life sciences. Commercial widefield microscopes generally use arc lamps, excitation/emission...Full Text Available

166

Improved DNA Sequencing Accuracy and Detection of Heterozygous Alleles Using Manganese Citrate and Different Fluorescent Dye Terminators  

UK PubMed Central (United Kingdom)

The use of dideoxynucleotide triphosphates labeled with different fluorescent dyes (dye terminators) is the most versatile method for automated DNA sequencing. However, variation in peak heights reduces...Full Text Available

1999-06-01

167

Host-Encoded Reporters for the Detection and Purification of Multiple Enveloped Viruses  

UK PubMed Central (United Kingdom)

The identification of host cell factors for virus replication holds great promise for the development of new anti-viral therapies. Recently, high-throughput screening methods have emerged as...Full Text Available

2010-08-01

168

High-density multiplex detection of nucleic acid sequences: oligonucleotide ligation assay and sequence-coded separation.  

UK PubMed Central (United Kingdom)

We describe a non-isotopic, semi-automated method for large-scale multiplex analysis of nucleic acid sequences, using the cystic fibrosis transmembrane regulator (CFTR) gene as an example. Products...Full Text Available

1994-10-25

169

High-Throughput Screen for Poly-3-Hydroxybutyrate in Escherichia coli and Synechocystis sp. Strain PCC6803  

UK PubMed Central (United Kingdom)

A novel, quantitative method for detecting poly-3-hydroxybutyrate (PHB) amounts in viable cells was developed to allow for high-throughput screening of mutant libraries. The staining technique was demonstrated...Full Text Available

2006-05-01

170

Gene expression analysis of interferon ? in laser capture microdissected cervical epithelium  

UK PubMed Central (United Kingdom)

Optimal sample handling techniques for tissue preparation and storage, RNA extraction and quantification, and target gene detection are crucial for reliable gene expression analysis. Methods...Full Text Available

2008-10-01

171

Gear fault detection using customized multiwavelet lifting schemes  

Science.gov (United States)

Fault symptoms of running gearboxes must be detected as early as possible to avoid serious accidents. Diverse advanced methods are developed for this challenging task. However, for multiwavelet transforms, the fixed basis functions independent of the input dynamic response signals will possibly reduce the accuracy of fault diagnosis. Meanwhile, for multiwavelet denoising technique, the universal threshold denoising tends to overkill important but weak features in gear fault diagnosis. To overcome the shortcoming, a novel method incorporating customized (i.e., signal-based) multiwavelet lifting schemes with sliding window denoising is proposed in this paper. On the basis of Hermite spline interpolation, various vector prediction and update operators with the desirable properties of biorthogonality, symmetry, short support and vanishing moments are constructed. The customized lifting-based multiwavelets for feature matching ...

2010-07-01

172

Failure to detect circulating DNA--anti-DNA complexes by four radioimmunological methods in patients with systemic lupus erythematosus.  

UK PubMed Central (United Kingdom)

The presence of DNA-anti-DNA complexes in sera from patients with systemic lupus erythematosus (SLE) was investigated by two new radioimmunoassays (RIA) developed for this purpose and by measuring the...Full Text Available

1977-12-01

173

Effective audit trails--a taxonomy for determination of information requirements.  

UK PubMed Central (United Kingdom)

Current methods of detecting confidentiality breaches in electronic medical record systems are inadequate, partially due to the lack of necessary information at the point of audit trail analysis. In...Full Text Available

1999-01-01

174

Detection of Unculturable Bacteria in Periodontal Health and Disease by PCR  

UK PubMed Central (United Kingdom)

Recently developed molecular methods have made it possible to characterize mixed microflora in their entirety, including the substantial numbers of bacteria which do not grow on artificial culture media....Full Text Available

1999-05-01

175

Detection of Chlamydia trachomatis in genital swabs: comparison of commercial and in house amplification methods with culture  

UK PubMed Central (United Kingdom)

AIMS: To evaluate the sensitivity of the Roche Cobas, Roche Amplicor plate kit, ligase chain reaction (LCR), and an in house polymerase chain reaction (PCR) by titration of purified elementary bodies...Full Text Available

1998-08-01

176

Detection of Atopobium vaginae in Postmenopausal Women by Cultivation-Independent Methods Warrants Further Investigation  

UK PubMed Central (United Kingdom)

We sequenced 16S rRNA genes from the vaginal swab contents of a postmenopausal woman with asymptomatic bacterial vaginosis (BV). Sequences from Atopobium vaginae were the most commonly...Full Text Available

2004-04-01

177

Comparative experimental study of dual energy subtraction and conventional digital radiography on chest  

International Nuclear Information System (INIS)

Objective: To compare the efficiency of dual energy subtraction and conventional direct digital radiography in signal detecting ability. Methods: 200 plastic balls which were 4 mm in diameter were taken as signals and were placed on a 10 cm thick plastic board and the right upper thorax of a healthy volunteer. The signals were examined by DES and CDR separately and were estimated by 3 radiologists with 5-value-differentiation method. ROC curve analysis was made by ROC kit software. Results: when signals on plastic board were detected by CDR and DES, ROC curve analysis indicated that there was no significant difference (P=0.4851 > 0.05, two-tailed) between the area under the ROC curves of the two methods (Az=0.9931 for CDR and Az=0.9879 for DES). The difference was significant (P=0.0002 <0.01, two-tailed) between the area under the ROC curves of CDR and DES (Az=0.7276 for CDR ...

2005-06-01

178

Clinical significance of Fas and FasL protein expression in gastric carcinoma and local lymph node tissues  

UK PubMed Central (United Kingdom)

AIM: To investigate the relation of Fas and Fas ligand (FasL) protein expression with carcinogenesis and metastasis of gastric carcinoma.METHODS: Immunohistochemistry was used to detect Fas and...Full Text Available

2010-03-14

179

Analysis of Quantitative Interactions between Two Species of Arbuscular Mycorrhizal Fungi, Glomus mosseae and G. intraradices, by Real-Time PCR  

UK PubMed Central (United Kingdom)

Arbuscular mycorrhizal fungi (AMF) are obligate biotrophs, known to play an important role in ecological processes. Conventional light microscopy is the most common method used to detect their presence...Full Text Available

2006-06-01

180

A double antibody solid phase assay for DNA autoantibodies for clinical use.  

UK PubMed Central (United Kingdom)

DNA antoantibodies in serum will bind to antigen-coated polystyrene tubes and can be detected by radiolabelled anti-immunoglobulin. The method is quantitative, gives information on the antibody class...Full Text Available

1976-08-01

181

A convenient and sensitive allergy test: IgE crosslinking-induced luciferase expression in cultured mast cells  

UK PubMed Central (United Kingdom)

BackgroundFor the detection of allergen-specific IgE in sera, solid-phase IgE-binding assays like the CAP test are commonly used. Although such immunochemical methods are very sensitive,...Full Text Available

2010-10-01

182

A Simple Colorimetric Assay for Specific Detection of Glutathione-S Transferase Activity Associated with DDT Resistance in Mosquitoes  

UK PubMed Central (United Kingdom)

BackgroundInsecticide-based methods represent the most effective means of blocking the transmission of vector borne diseases. However, insecticide resistance poses a serious threat...Full Text Available

183

A Hybrid Capillary-Microfluidic Device for the Separation, Lysis, and Electrochemical Detection of Vesicles  

UK PubMed Central (United Kingdom)

The primary method for neuronal communication involves the extracellular release of small molecules that are packaged in secretory vesicles. We have developed a platform to separate, lyse, and...Full Text Available

2009-03-15

184

Analysis of o-tyrosine as a method for the identification of irradiated chicken and the comparison with other methods (analysis of volatiles and ESR-spectroscopy)  

Energy Technology Data Exchange (ETDEWEB)

With the mentioned method to analyse O-tyrosine with HPLC/fluorescence-detection, the irradiation of chicken meat can be determined in a simple and fast way. The formation of o-tyrosine is proportional to the applied dose but because it is also depending on the applied dose rate and the temperature during the irradiation, it is not possible to control the irradiation dose. Since unirradiated chicken can contain little amounts of o-tyrosine and to confirm some results, a second method is needed. Together with one of the other mentioned methods (analysis of the volatiles or esr-spectroscopy) it is possible to recognize irradiated chicken with a high security. (author).

1990-01-01

185

Practical measurement of diffusion constants in sintered zirconias by using a light-scattering method  

Energy Technology Data Exchange (ETDEWEB)

A practical method to determine the ionic diffusion coefficient and activation energy by using quasielastic light scattering (QELS) is presented. It is shown that a temperature dependence curve of the QELS intensity at a fixed frequency can be well fitted by Jonscher's formula and that the diffusion parameters can be obtained from this curve fitting. This method is successfully applied not only to crystals with high optical quality, as reported earlier, but also to opaque ceramics, which are more important than the crystals from a practical point of view. The composition dependence of the ionic diffusion coefficient is studied in sintered YbSZ to show the usefulness of this method.

1991-03-01

186

Development of an analysis rule of diagnosis error for standard method of human reliability analysis  

International Nuclear Information System (INIS)

This paper presents the status of development of Korea standard method for Human Reliability Analysis (HRA), and proposed a standard procedure and rules for the evaluation of diagnosis error probability. The quality of KSNP HRA was evaluated using the requirement of ASME PRA standard guideline, and the design requirement for the standard HRA method was defined. Analysis procedure and rules, developed so far, to analyze diagnosis error probability was suggested as a part of the standard method. And also a study of comprehensive application was performed to evaluate the suitability of the proposed rules.

2003-10-01

187

Developing methods for testing and monitoring packing, detachable connections used in well geophysical apparatus. O razrabotke metodov ispytaniy i kontrolya uplotnitel'nykh raz''yemnykh soyedineniy, primenyayemykh v skvazhinnoy geofizicheskoy apparature  

Energy Technology Data Exchange (ETDEWEB)

Development of surface monitoring of the quality of round rubber packing rings for well instruments is discussed. A method is shown for testing the rings under conditions which simulate the operating conditions. A method is proposed for rapid monitoring of the conditions for vulcanization of the rings by the method of determining the ''ring modulus.''

1983-01-01

188

The sensory quality of irradiated breaded poultry products  

International Nuclear Information System (INIS)

The colour, odour, flavour and texture of a breaded turkey escalope irradiated at doses of 2 and 4 kGy was assessed using a trained sensory panel. Irradiation did not affect raw appearance but during storage the irradiated breaded products became paler than the control samples. The off odour of the raw irradiated products was stronger than that of the unirradiated samples. Irradiation also affected the odour, flavour and texture of the cooked products. Although the trained panelists were able to detect significant differences between irradiated and unirradiated breaded turkey escalopes, the numerical differences between treatments were often quite small. It is possible that an untrained consumer group would be unable to detect these differences. Further research is needed with consumer groups to establish if irradiated breaded products are acceptable. (author). 10 refs, 3 tabs.

1994-07-01

189

Suitability of Molecular Markers for Selection of Potatoes Resistant to Globodera spp  

British Library Electronic Table of Contents (United Kingdom)

Globodera rostochiensis and Globodera pallida are parasitic root cyst nematodes of potato (PCN), which significantly reduce yield and quality. The genetics and available molecular markers should make resistance to nematodes an excellent candidate for marker assisted selection. The study presents results of testing the suitability of known molecular markers for detection of resistance in a set of cultivars. We revealed some inconsistencies in genealogical data of the cultivars and showed inconsistent usefulness in detecting resistant cultivars. The marker TG689 was identified in almost all cultivars resistant to G. rostochiensis and together with other markers was used for verifying the resistance in a group of breeding lines. The marker TG689 was the most effective. However, the efficiency...

2011-01-01

190

Identification of pork derivatives in food products by species-specific polymerase chain reaction (PCR) for halal verification  

British Library Electronic Table of Contents (United Kingdom)

Pork identification in four types of food products, which are sausages and the casings, bread and biscuits, using species-specific polymerase chain reaction (PCR) detection of a conserved region in the mitochondrial (mt) 12S ribosomal RNA (rRNA) gene was developed. Genomic DNA of the food products were successfully extracted except for the casing samples, where no genomic DNA was detected. The extracted genomic DNA was then subjected to PCR amplification targeting the specific regions of the 12S rRNA gene. The genomic DNA from the food products were found to be of good quality and produced clear PCR products on the amplification of 12S rRNA gene of 387 base pairs (bp) from pork species. The species-specific PCR identification yielded excellent results for identification of pork derivatives...

2007-01-01

191

New remote sensing techniques for the detection and quantification of earth surface CO2 degassing  

British Library Electronic Table of Contents (United Kingdom)

Earth degassing specifically of carbon dioxide CO2 is of increasing interest with respect to the global carbon budget, related climate effects, earthquake and volcano eruption mechanisms, as well as plant physiological reactions in gas-rich environments. Investigations in all of these disciplines require the detection of surface CO2 degassing structures and quantification of their emissions. We introduce minimal thermal change detection based on infrared imaging as a new remote sensing tool for the detection of earth surface thermal anomalies suiting among others to discover earth degassing locations of any origin. The method allows for seamless areal search and monitoring of degassing structures in any terrain. As proof of concept infrared imaging measurements were performed at the Bossol...

2008-01-01

192

Idaho National Laboratory Supervisory Control and Data Acquisition Intrusion Detection System (SCADA IDS)  

Energy Technology Data Exchange (ETDEWEB)

Current Intrusion Detection System (IDS) technology is not suited to be widely deployed inside a Supervisory, Control and Data Acquisition (SCADA) environment. Anomaly- and signature-based IDS technologies have developed methods to cover information technology-based networks activity and protocols effectively. However, these IDS technologies do not include the fine protocol granularity required to ensure network security inside an environment with weak protocols lacking authentication and encryption. By implementing a more specific and more intelligent packet inspection mechanism, tailored traffic flow analysis, and unique packet tampering detection, IDS technology developed specifically for SCADA environments can be deployed with confidence in detecting malicious activity.

2008-05-01

193

Comparison of media and methods for detecting and enumerating Listeria monocytogenes in refrigerated cabbage.  

Science.gov (United States)

Direct plating, selective enrichment, and cold enrichment followed by secondary selective enrichment procedures were compared for detecting and enumerating Listeria monocytogenes in chopped cabbage stored at 5 degrees C for up to 64 days. Addition of Fe3+ to solid media enhanced detection of the organism. Cold enrichment (5 degrees C) in nutrient broth and brain heart infusion broth followed by secondary enrichment (48 h, 30 degrees C) in Trypticase soy-yeast extract-antibiotic broth and thiocyanate-nalidixic acid broth and plating on selective agar media (Doyle and Schoeni selective enrichment agar [minus acriflavin hydrochloride, supplemented with 5 micrograms of Fe3+/ml] and McBride Listeria agar) resulted in the detection of highest populations. PMID:3111369

1987-05-01

194

Use of internal quality control materials for the preparation and maintenance of reliable methods for the measurement of lead in blood  

Energy Technology Data Exchange (ETDEWEB)

The performance of a group of reference laboratories measuring lead in blood, has been monitored by an intensive external quality assessment programme, since 1974. Performance was similar to that observed in other, larger quality control surveys but rapidly improved following detailed investigations of critical factors in the analytical methodology. The introduction of a rigorous internal quality control protocol, with all laboratories using the same well-characterised materials, has produced external quality control results that are both accurate and very tightly distributed. Between-laboratory coefficients of variation of less than 5%, less than 6% and less than 20% are now obtained at concentrations of over 1.0 ..mu..mol/l (20.7 ..mu..g/dl), 0.5-1.0 ..mu..mol/l (10-20 ..mu..g/dl) and less than 0.5 ..mu..mol/l (10 ..mu..g/dl), respectively. These results represent the best that can be achieved by ...

1988-12-01

195

Precooling techniques and applications for horticultural products - a review  

Energy Technology Data Exchange (ETDEWEB)

One of the most important factors affecting the postharvest life and quality of horticultural crops is temperature. Quality loss after harvest occurs as a result of physiological and biological processes, the rates of which are influenced primarily by product temperature. As the maintenance of market quality is of vital importance to the success of the horticultural industry, it is necessary not only to cool the product but to cool it as quickly as possible after harvest. The process of precooling is the removal of field heat which arrest the deteriorative and senescence processes so as to maintain a high level of quality that ensures customer satisfaction. This paper provides a critical review to portray precooling as an intricate part of temperature management and to highlight the importance of its utilisation for extending the shelf life and maintaining the quality of ...

2001-07-01

196

Improving safety and quality: how can education help?  

Science.gov (United States)

National efforts to improve the quality and safety of health care present challenges for medical education and training. Today's doctors need to be skilled communicators who know how to identify, prevent and manage adverse events and near misses, how to use evidence and information, how to work safely in a team, how to practise ethically, and how to be workplace teachers and learners. These competencies (knowledge, skills and attitudes) are set out in the National Patient Safety Education Framework (NPSF) of the Australian Council for Safety and Quality in Health Care. The NPSF is designed to help medical schools, vocational colleges, health organisations and private practitioners develop curricula to enable health professionals to work safely. The NPSF describes what doctors (depending on their level of knowledge and experience) can do to demonstrate competencies in a range of quality and safety activities. Medical ...

2006-05-15

197

Comparison of the quality of the chest film between digital radiography and conventional high kV radiography  

International Nuclear Information System (INIS)

Objective: To evaluate the quality and usefulness of direct digital radiography system in roentgenogram of chest in clinical practice. Methods: 1000 cases of chest roentgenograms with digital radiography and high kV conventional radiography were selected for analysis by 3 senior radiologists. Results: 1. With digital radiography system, the quality of chest film was assessed as grade A in 50.6%, grade B in 38.5%, grade C in 10.9%, and no waste film. 2. With conventional high kV radiography, the quality of chest film was assessed as grade A in 41.1%, grade B in 44.1%, grade C in 13.3%, and waste film in 1.5%. The direct digital radiography was statistically superior to the conventional high kV radiography. 3. The fine structure of the lungs could be revealed in 100.0% of chest roentgenogram with direct digital radiograph system, which was significantly higher than that acquired with the conventional high ...

2003-02-01

198

Enabling Technology for Monitoring & Predicting Gas Turbine Health & Performance in IGCC Powerplants  

Energy Technology Data Exchange (ETDEWEB)

The ''Enabling & Information Technology To Increase RAM for Advanced Powerplants'' program, by DOE request, was re-directed, de-scoped to two tasks, shortened to a 2-year period of performance, and refocused to develop, validate and accelerate the commercial use of enabling materials technologies and sensors for coal/IGCC powerplants. The new program was re-titled ''Enabling Technology for Monitoring & Predicting Gas Turbine Health & Performance in IGCC Powerplants''. This final report summarizes the work accomplished from March 1, 2003 to March 31, 2004 on the four original tasks, and the work accomplished from April 1, 2004 to July 30, 2005 on the two re-directed tasks. The program Tasks are summarized below: Task 1--IGCC Environmental Impact on high Temperature Materials: The first task was refocused to address IGCC environmental impacts on high temperature materials used in gas turbines. This task ...

2005-12-01

199

Quality control and evaluation for environmental radiological baseline study of Guangdong Daya Bay nuclear power station  

International Nuclear Information System (INIS)

The main points of quality control methods and technique of environmental radiological baseline study of Guangdong Daya Bay Nuclear Power Station are reported. Results of intercalibration of international and inland laboratories are given. The random chosen samples are checked and compared with two measurement methods. The data obtained in Daya Bay environment are put to the correlation statistics test using the linear regression analysis method between the correlative items such as "4"0K activity by gamma spectrum measurement and potassium content by chemical analysis, total #alpha#(#beta#) activity and nuclide content, as well as environmental gamma radiation dose rate and TLD accumulation dose. The data of Daya Bay environmental radioactivity baseline level show good concordance and reliability.

200

Nanocontact heteroepitaxy of thin GaSb and AlGaSb films on Si substrates using ultrahigh-density nanodot seeds.  

Science.gov (United States)

A film of GaSb grown epitaxially on a Si substrate is a direct transition semiconductor useful for application as a light source in Si photonics and channel material in next-generation field effect transistors because its energy bandgap is close to the optical fibre communication wavelength and it possesses high carrier mobility. Here, we report a novel method for heteroepitaxial growth of high-quality GaSb/Si films, despite having a lattice mismatch as large as ? 12%, using elastically strain-relaxed GaSb nanodots with ultrahigh density as seed crystals for film growth. The nanodot seed crystals were grown epitaxially by restricted contact with the Si substrate through nanowindows in an ultrathin SiO(2) film on the Si substrate. A light-emitting diode containing GaSb/Si films with a thickness of ? 90 nm fabricated by this method operated at room temperature. The growth method was also used to fabricate ...

2011-05-17

201

Robust line width estimation  

Energy Technology Data Exchange (ETDEWEB)

Fabrication of diffused titanium optical guides on a LiNbO/sub 3/ crystal substrate requires precise quality assurance. Light couplers in particular must be positioned within micron specifications. This requirement is the reason that the width of lines detected during microscopic inspection of the crystal is such an important parameter for quality evaluation. To assist in the inspection of these optical guides, a line width estimation program has been developed for an IBM PC based microscope inspection system. A digital image processing approach is used to develop an algorithm which can be tailored by the user for specific signal and noise characteristics. Default filter parameters, which can be updated and saved interactively by the user, are stored in a file on disk. The final program can be executed stand-alone or through a commercially available, menu-driven, image processing software package. Details concerning the ...

1986-07-01

202

Thermal stability of coke  

Science.gov (United States)

A method is presented for calculating the thermal stability of blast furnace coke over a wide range of sizes, based on a study of the coke behaviour pattern in the blast furnace and the change in its thermo-elastic properties during reheating. Using as an example a Novolipetsk metallurgical plant, the possibility was demonstrated of using the thermal stability index calculated by the proposed method for an unambiguous assessment of the quality of blast furnace coke.

1983-01-01

203

The scintigraphy of the brain: development, methods and present consequence  

International Nuclear Information System (INIS)

Brain scintiscanning which was first carried out exclusively 'statical' and only with test substances of limited quality has been replaced nowadays by 'dynamical' camera-sequency-scintiscanning with technetium. This brought considerable progress not only for identifying but also for the differential diagnosis of cerebro-organic processes. Development, methods, and integration of brain scintiscanning in a diagnostical conception are described briefly. (orig.).

204

Determination of heavy metals in welders' working environment using nuclear analytical methods  

International Nuclear Information System (INIS)

Technological processes of welding are significant sources of pollution in the working area. Evaluation of chemical quality of working area was made by means of radionuclide x-ray fluorescence analysis and activation analysis with fast neutrons. Welding aerosols were sampled by filtration method on Synpor 4 membrane ultra-filters. For selected types of welding filter metals, determination of heavy metals in aerosols was performed. (author).

1985-01-01

205

Determination of heavy metals in welders' working environment using nuclear analytical methods  

Energy Technology Data Exchange (ETDEWEB)

Technological processes of welding are significant sources of pollution in the working area. Evaluation of chemical quality of working area was made by means of radionuclide x-ray fluorescence analysis and activation analysis with fast neutrons. Welding aerosols were sampled by filtration method on Synpor 4 membrane ultra-filters. For selected types of welding filter metals, determination of heavy metals in aerosols was performed.

1985-01-03

206

Modern imaging methods for diagnostic evaluation of tumors of the oropharynx and the oral cavity  

International Nuclear Information System (INIS)

Differentiating a benign from a malignant lesion by information such as density data, or signal intensities or echo gradients, is not possible with CT, nor MRI, nor ultrasonography. Only some lesions show characteristic signs. Inflammations cannot be difscriminated from malignant tumors. CTs of small tumors in particular are so poor in contrast that it is much more difficult to detect tumors or discriminate them from other lesions, as compared to MR images or ultrasonographs. CT does not detect surface tumors, but is more sensitive than MRI or US in detecting discrete cortical bone lesions. The same applies to small calcified tumors. MRI however is most sensitive in detecting tumor volumes in the yellow marrow, and is the best modality for evaluation of extraossal extension of tumors. CT yields better results than MRI if applied for simultaneous screening of lymph node metastases in the lower neck. MRI ...

207

A systematic review to investigate the effectiveness and acceptability of interventions for moist desquamation in radiotherapy patients  

Energy Technology Data Exchange (ETDEWEB)

Aim: To systematically review the currently available high quality evidence evaluating treatments for moist desquamation in radiotherapy patients. Design: Systematic literature review. Methods: Electronic databases, websites, reference lists, key journals and conference proceedings were searched. Attempts were also made to uncover unpublished material. Relevant studies proceeded to data extraction and quality assessment. Results: Twenty studies were found; 10 were eligible for inclusion. Although many studies were small, none had unacceptably poor quality. No meta-analysis was undertaken as the studies were not homogenous in their interventions or methods. No convincing evidence for any intervention was found. Conclusion: Despite being recommended by many guidelines (College of Radiographers Summary of Intervention for Acute Radiotherapy Induced Skin Reactions in Cancer Patients ...

2009-08-15

208

Hierarchical Kohonenen net for anomaly detection in network security.  

Science.gov (United States)

A novel multilevel hierarchical Kohonen Net (K-Map) for an intrusion detection system is presented. Each level of the hierarchical map is modeled as a simple winner-take-all K-Map. One significant advantage of this multilevel hierarchical K-Map is its computational efficiency. Unlike other statistical anomaly detection methods such as nearest neighbor approach, K-means clustering or probabilistic analysis that employ distance computation in the feature space to identify the outliers, our approach does not involve costly point-to-point computation in organizing the data into clusters. Another advantage is the reduced network size. We use the classification capability of the K-Map on selected dimensions of data set in detecting anomalies. Randomly selected subsets that contain both attacks and normal records from the KDD Cup 1999 benchmark data are used to train the hierarchical net. We use a confidence ...

2005-04-01

209

Fatigue crack detection in aircraft skin structures using eddy current array technique  

International Nuclear Information System (INIS)

Detection of fatigue damage cracks in aircraft skin structures is an ongoing NDT challenge. Cracks growing rate is difficult to predict, and for this reason, it is important to detect them as soon as possible to avoid a catastrophic break. Eddy current methods are known and well-accepted techniques which are relatively simple to carry out. However, with conventional inspection of airframe structures using standard driver-pickup eddy current probes, it is difficult to detect small fatigue cracks initiated in the second layer of the skin and in the shadow region at fastener holes. Such difficulty is related to fasteners length and their spacing which reduces test sensitivity. This report explains the development of improved eddy current probe/technique to detect and visualize fatigue cracks in fasteners. In this study, an eddy current array probe was evaluated and new coil design was ...

2004-01-01

210

Sorbent extraction and high performance liquid chromatography (HPLC) of homidium bromide and isometamidium chloride in bovine plasma  

International Nuclear Information System (INIS)

Homidium bromide and isometamidium chloride are used extensively in the treatment of bovine trypanosomiasis in Africa, but no specific and sensitive method to detect the drug in plasma has been published yet. Comparing the methods of other investigators it was found that they could not overcome the protein binding of these drugs which reduced the available and determined drug to 10% of the real concentrations. These techniques overcome the protein binding by enzyme digestion and an alteration of the pH before adding the sample directly on clean-up columns. Drug recover rates above 80% were obtained. For the detection, the HPLC was employed using a C18 reversed phase analytical column and UV detection, determining both drugs as intact molecules. (author).

1992-01-01

211

Mining User Comment Activity for Detecting Forum Spammers in YouTube  

CERN Document Server

Research shows that comment spamming (comments which are unsolicited, unrelated, abusive, hateful, commercial advertisements etc) in online discussion forums has become a common phenomenon in Web 2.0 applications and there is a strong need to counter or combat comment spamming. We present a method to automatically detect comment spammer in YouTube (largest and a popular video sharing website) forums. The proposed technique is based on mining comment activity log of a user and extracting patterns (such as time interval between subsequent comments, presence of exactly same comment across multiple unrelated videos) indicating spam behavior. We perform empirical analysis on data crawled from YouTube and demonstrate that the proposed method is effective for the task of comment spammer detection.

2011-01-01

212

Final report: technical contributions to the development of incipient fault detection/location instrumentation  

Energy Technology Data Exchange (ETDEWEB)

The transmission of electrical energy by use of underground cables is increasing. Fault location techniques have certain limitations; incipient fault detection and location would help reduce the maintenance cost of these lines as well as improve the reliability of service. The report discusses some test results related to RF-probing techniques applied to high-voltage transmission lines. The high-frequency losses and attenuation in high-voltage cables places certain ultimate limitations on RF-probing techniques for incipient fault detection. Time-domain reflectrometry methods were employed to assess the RF-transmission properties of high-voltage cables at frequencies as high as 6 GHz. Fast-Fourier-transform deconvolution was used to obtain loss measurements as a function of frequency. The loss mechanisms were identified. The measurement hardware and methods are discussed as well as analysis approach ...

1986-04-01

213

Identification of oxidation states of ultra-trace elements by radiation detection  

International Nuclear Information System (INIS)

The determination of the oxidation state of ultra-trace elements in the environment, especially in the case of actinides, is of importance in many ways. Speciation techniques using radiation may comprise methods based on the detection of the nuclear and atomic radiations emitted in radioactive decay or methods using external sources of excitation. In the former instance, information can be obtained from the energy and intensity of radiation, but at present the partition method is still the most commonly used, although its reliability is questionable. Excitation with intense laser beams, as is currently being used for trace element analysis in photoacoustic and thermal lensing spectroscopic techniques, could conceivably be applied under suitable conditions to ultra-trace elements with a sensitivity approaching that of the radiochemical methods.

1989-11-01

214

''SEPIO NUANCE DT'' digital mammography system  

International Nuclear Information System (INIS)

In the past, the need for high quality images, i.e., very sharp and clear images, in mammography have prevented mammography equipment from being digitalized; however, recent advances in detection technology such as development of a high resolution digital X-ray detector have produced improvements in digital mammography. Digital mammography is expected to replace conventional film-screen mammography. We have developed a digital mammography system, named ''SEPIO NUANCE DT'', which is equipped with a direct conversion flat panel detector. The present paper describes the high basic performance and user-friendly functions of the system. (author)

2007-03-01

215

"1H MR spectroscopy in pediatrics  

International Nuclear Information System (INIS)

Spectral appearance and concentrations of the most prominent metabolites are affected by brain development. This knowledge is essential for the detection of pathological changes in pediatric patients. This paper discusses specific conditions of MR spectroscopic examination of children and the effects of age on MR spectra quality and quantitation of the studied metabolites. Clinical examples show several diseases that are reflected in changes in "1H MR spectra due to pathological alterations in the biochemical pathways of the observed metabolites. Attention is given to the main metabolites such as N-acetylaspartate, creatine/phosphocreatine, cholines, lactate, inositol, etc.

2008-08-01

216

Subthreshold depression in Parkinson's disease  

British Library Electronic Table of Contents (United Kingdom)

AbstractBackground: Quality of life in Parkinson patients with subthreshold depression could be improved if the prevalence and symptom profile were better understood. Methods: Our study used standard DSM-IV and Judd criteria as well as motor, depression, and quality-of-life scales to investigate a sample of 110 nondemented Parkinson patients. This led to formation of nondepressed (48.2%), subthreshold depressed (25.5%), and depressed (26.4%) groups. Results: Quality of life was seen to be significantly lower in subthreshold depressed patients than in the nondepressed, and there were differences in the frequency of depressive symptoms that partially overlapped with nonmotor symptoms of vegetative origin in Parkinson's disease (appetite, sleep disorders). Key measures of depression (diminish...

2011-01-01

217

On-farm water management in saline groundwater area under scarce canal water supply condition in the Northwest India  

British Library Electronic Table of Contents (United Kingdom)

The study investigates the possibility of enhancing crop water productivity in the parts of Northwest India where groundwater quality is marginal and canal water supply is severely scarce. Soil, Water, Atmosphere and Plant (SWAP) model was calibrated and validated in three farmers' fields with varying canal water availability and groundwater quality in the Kaithal Irrigation Circle of the Bhakra Canal system, Haryana. On the basis of predicted and observed soil water content, pressure heads, salt concentration at 2 week intervals and crop yields, the model was found suitable for use in the region. A few nomographs were prepared to provide a graphical method to predict the effect of different combinations of water quality and depth of water application on crop yield and soil salinity and to...

2008-01-01

218

Depression, coronary artery disease, type 2 diabetes, metabolic syndrome and quality of life in Taiwanese adults from a cardiovascular department of a major hospital in Southern Taiwan  

British Library Electronic Table of Contents (United Kingdom)

Aims.- To examine the relationships between depression, coronary artery disease, type 2 diabetes, metabolic syndrome and quality of life in Taiwanese adults from a cardiovascular department of a major hospital in Taiwan. Background.- Research suggests associations between depression, metabolic syndrome and quality of life. Despite this fact, few studies have investigated these relationships among Taiwanese. Design.- A cross-sectional descriptive correlational design was used to conduct this study. Methods.- A convenience sample of 140 adults participated in the study. Data were analysed with descriptive statistics, Pearson-s correlations, hierarchical regression and t-tests. Results.- Almost a half of the subjects (465%) had metabolic syndrome. The most common combination of metabolic synd...

2011-01-01

219

Tests of effective utilization of industrially produced materials: soil engineering properties and earthworking problems of coal ash and red mud  

Energy Technology Data Exchange (ETDEWEB)

An account of problems arising in the use of coal ash and red mud as filling or banking materials. The soil engineering properties of these materials are explained. Problems encountered in on-site use include difficulty in controlling moisture content, absorption swelling and strongly alkaline atmospheres. For long-term use, it will be necessary to minimize the variations in engineering characteristics and in quality that result from the method of discharge and from the raw materials themselves. There must also be thorough quality control during shipment. (7 refs.) (In Japanese)

1982-01-01

220

Remote on-board coal quality sensing techniques in coal cutting and handling systems  

Energy Technology Data Exchange (ETDEWEB)

A review of the literature was undertaken to determine the potential for development of instrumentation for on-board remote sensing of coal quality. This review report acts as an inventory of commercially available techniques being tested or under development, particularly in the areas of the cutting horizon measurement methods associated with longwall mining equipment and coal/waste monitoring techniques in coal handling systems. While technology is available which can discriminate rocks from coal on a conveyor belt, the literature indicates that this hardware has yet to be adapted to continuous surface mining machines. 23 refs., 18 figs.

1987-09-01

221

Quality Concepts for the Improved Use of Recycled Polymeric Materials: A Review  

British Library Electronic Table of Contents (United Kingdom)

Polymeric waste materials should be considered resources for the manufacture of new products through recycling processes, with a similar status to virgin fossil-based plastics and biopolymers from renewable resources. Several efforts can be made to achieve this qualitative quantum leap in plastics recycling, and consequently introduce recycled products, with competitive performance, to the market. Scientific knowledge about the degradation processes during the life cycle and the development of fast and reliable analytical methods for the quality assessment of recycled plastics are fundamental to guarantee their performance in new applications. Different strategies-restabilisation, rebuilding, compatibilisation, and addition of elastomers and fillers-can be used to upgrade the structure and...

2008-01-01

222

New demands to satisfy for air quality monitoring organisms; De nouvelles demandes a satisfaire pour les organismes de surveillance de la qualite de l'air  

Energy Technology Data Exchange (ETDEWEB)

The measurement of air pollutants is no more sufficient. It is necessary to assess the risk induced by air pollution, and then to put in place actions to reduce it. The air quality monitoring takes into account different pollutants: nitrogen oxides, carbon monoxide, particulates for the traffic; sulfur dioxide and particulates for use of fuel or coal or chemical transformations in air; ozone and nitrogen dioxide from hydrocarbon and nitrogen oxides emissions; the use of simulation methods allow to calculate the concentrations levels for these pollutants taken as indicators. (N.C.)

2000-07-01

223

Investigations of the metallurgical characteristics of different cokes for cupola furnace operation. Pt. 1; Materials and methods. Untersuchung des metallurgischen Verhaltens unterschiedlicher Kokssorten fuer den Kupolofenbetrieb. T. 1; Voraussetzungen und untersuchte Kokse  

Energy Technology Data Exchange (ETDEWEB)

The report discusses: Combustion characteristics of various commercial cokes for cupola furnace operation; quality level of modern cokes; foundry coke, blast furnace coke, MB coke; characteristic data, e.g. grain size distribution, drum resistance, concentrations of water, carbon, sulphur, ash, and volatiles, reactivity; changes in coke quality during transport. (HS)

1993-06-14

224

Adaptive Waveform Correlation Detectors for Arrays: Algorithms for Autonomous Calibration  

Energy Technology Data Exchange (ETDEWEB)

Waveform correlation detectors compare a signal template with successive windows of a continuous data stream and report a detection when the correlation coefficient, or some comparable detection statistic, exceeds a specified threshold. Since correlation detectors exploit the fine structure of the full waveform, they are exquisitely sensitive when compared to power (STA/LTA) detectors. The drawback of correlation detectors is that they require complete knowledge of the signal to be detected, which limits such methods to instances of seismicity in which a very similar signal has already been observed by every station used. Such instances include earthquake swarms, aftershock sequences, repeating industrial seismicity, and many other forms of controlled explosions. The reduction in the detection threshold is even greater when the techniques are applied to arrays since stacking can be ...

2009-07-23

225

The magnetic resonance and its agro-industry applications; a review  

International Nuclear Information System (INIS)

The electromagnetic properties that present hydrogen and other nucleus of agro-alimentary products, have allowed widely use of magnetic resonance (MR) to study the composition and internal structure of these biological materials in a micro and macroscopic scale, in a nondestructive way. In this paper the physical principles, basic equipment to measure the MR signals and the MR imaging of any biological sample, are explained. It is also shown a review of the main agro-alimentary applications, emphasizing in the use of this principle to examine the internal quality of fruits and vegetables. In these products, the MR has been used to detect and follow the evolution of different factors that determine the internal quality after harvesting, during storage and after post harvesting processes. The main studies that have been conducted with MR in harvested products are about physiological disorders that take place during storage ...

226

Radiotherapy quality insurance by individualized in vivo dosimetry: state of the art; Dosimetrie individuelle in vivo pour le controle de qualite en radiotherapie: etat de l'art  

Energy Technology Data Exchange (ETDEWEB)

The quality insurance in radiotherapy in the frame of highly complex technical process as Intensity modulated radiotherapy (I.M.R.T.) needs independent control of the delivered dose to the patient. Actually, up to now, most of the radiotherapy treatments rely only on computed dosimetry through a rather complicated series of linked simulation tool. This dosimetry approach requires also qualified treatment means based on cautious quality insurance procedures. However, erroneous parameters could be difficult to detect and systematical errors could happen leading to radiotherapy accidents. In this context, in vivo dosimetry has a critical role of final control of the delivered dose. As many beam incidences and ports are used for any photon therapy treatment, external control could be very tedious and time consuming. Therefore, innovations are needed for in vivo dosimetry to provide ergonomic and efficient tools for these ...

2009-06-15

227

Fault detection by Turam TEM survey. Numerical model studies and a case history; TEM ho Turam sokutei haichi ni yoru danso kenshutsu no kokoromi. Model keisan to jisshirei  

Energy Technology Data Exchange (ETDEWEB)

With an objective to detect faults estimated to exist along the Shigesumi valley in the Kamioka mine, discussions were given by using electromagnetic survey, which uses the Turam measurement arrangement based on the TEM method, and three-dimensional model calculations. The Turam measurement arrangement, which installs transmission loop fixedly, is used to identify nature and distribution of electrically conductive objects upon noticing abnormal portions in magnetic fields in the measurement data. In the model calculation, the plate model calculation method and the FDTD method were used, and so was the calculation code TEM3DL. The result revealed that strong topographical influence is seen from steep V-shaped valley existing along the traverse line in the measurement data, but an abnormal resistivity band accompanying remarkable distortion in the curve was detected. According to the ...

1997-05-27

228

Shielded and unshielded geometries in the search for orphan sources  

Energy Technology Data Exchange (ETDEWEB)

A car-borne NaI(Tl) spectrometric system was used together with a {sup 137}Cs source to obtain realistic data in the search for unshielded and semi-shielded orphan sources. The potassium-stripped counts (PSC) method was used to estimate the influence by the shielding on the detection ability. A reduction of about 5% in the critical distance was obtained for the semi-shielded source. A curve fitting method was also developed and evaluated. Results from the curve fitting method showed inferior ability to find the source compared to the PSC method. However, it can be a useful complementary tool, for characterisation of the source shielding, and estimation of the distance from the road.

2006-05-15

229

Shielded and unshielded geometries in the search for orphan sources  

International Nuclear Information System (INIS)

A car-borne NaI(Tl) spectrometric system was used together with a "1"3"7Cs source to obtain realistic data in the search for unshielded and semi-shielded orphan sources. The potassium-stripped counts (PSC) method was used to estimate the influence by the shielding on the detection ability. A reduction of about 5% in the critical distance was obtained for the semi-shielded source. A curve fitting method was also developed and evaluated. Results from the curve fitting method showed inferior ability to find the source compared to the PSC method. However, it can be a useful complementary tool, for characterisation of the source shielding, and estimation of the distance from the road.

2006-05-01

230

Nondestructive testing of metal coating thickness and control of chemical composition using radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The principle is described of a method using low-activity emitters as the primary radiation source for analysis. The selection of the radiation source and the detection methods including the assessment of the applicability of various radiation detectors are discussed. The benefits and the constraints of the method are considered. Practical examples are presented showing the application possibilities of the method for testing the thickness of bearing layers, piston ring coats, lead layers, etc. The possibility is shown of applying the rapid test for the composition of tungsten and chromium alloyed metal materials in testing complex systems. (J.K.).

1974-12-03

231

A Two-Step Etching Method to Fabricate Nanopores in Silicon  

CERN Document Server

A cost effectively method to fabricate nanopores in silicon by only using the conventional wet-etching technique is developed in this research. The main concept of the proposed method is a two-step etching process, including a premier double-sided wet etching and a succeeding track-etching. A special fixture is designed to hold the pre-etched silicon wafer inside it such that the track-etching can be effectively carried out. An electrochemical system is employed to detect and record the ion diffusion current once the pre-etched cavities are etched into a through nanopore. Experimental results indicate that the proposed method can cost effectively fabricate nanopores in silicon.

2008-01-01

232

QTL mapping in outbred half-sib families using Bayesian model selection.  

Science.gov (United States)

In this article, we propose a model selection method, the Bayesian composite model space approach, to map quantitative trait loci (QTL) in a half-sib population for continuous and binary traits. In our method, the identity-by-descent-based variance component model is used. To demonstrate the performance of this model, the method was applied to map QTL underlying production traits on BTA6 in a Chinese half-sib dairy cattle population. A total of four QTLs were detected, whereas only one QTL was identified using the traditional least square (LS) method. We also conducted two simulation experiments to validate the efficiency of our method. The results suggest that the proposed method based on a multiple-QTL model is efficient in mapping multiple QTL for an outbred half-sib population and is more powerful than the LS method ...

2011-04-13

233

Simulation study using 3-D wavefield modeling for oil and gas exploration; Sanjigen hadoba modeling wo mochiita sekiyu tanko no simulation study  

Energy Technology Data Exchange (ETDEWEB)

As the surroundings of objects of oil exploration grow more complicated, seismic survey methods have turned 3-dimensional and, in this report, several models are examined using the 3-dimensional simulation technology. The result obtained by the conventional wave tracking method is different from actual wavefields, and is unrealistic. The difference method among the fullwave modelling methods demands an exorbitantly long computation time and high cost. A pseudospectral method has been developed which is superior to the difference method, and has been put to practical use thanks to the advent of parallel computers. It is found that a 3-dimensional survey is mandatory in describing faults. After examining the SEG/EAGE Salt model, it is learned that the salt is well-developed and that 3-dimensional depth migration is required for sub-salt exploration. It is also ...

1997-05-27

234

[Development of efficient DNA isolation procedures for Cryptosporidium and Trichinella PCR detection in fecal samples].  

Science.gov (United States)

PCR detection of genetic material of the parasites present in faeces may be an alternative for microscopic and serological tests routinely used for diagnosing parasitic enteral infections. However, small amount of target DNA combined with low efficiency of total DNA extraction, and presence of PCR inhibitors in the samples to be amplified, may cause false negative detection results. The aim of this work was to evaluate the impact of DNA isolation procedure used on the amplification of DNA fragments from the genomes of protozoan Cryptosporidium parvum and the nematode Trichinella spiralis. Two methods based on different principles of biological material lysis were evaluated; NucliSENS miniMAG employing simultaneously applied chemical lysis and mechanical disruption or mechanical disruption followed by enzymatic lysis in case of QIAamp DNA Stool Mini Kit. Both of the analyzed systems for nucleic acids purification allowed ...

2009-01-01

235

Quantitative analysis of iodine in thyroidin. II. Method of combustion in flask with oxygen  

Energy Technology Data Exchange (ETDEWEB)

The authors experimentally study the separate stages of the determination of iodine in thyroidin by the combustion method in a flask with oxygen. The monotypic, conventional procedures and the procedure of Kolii and Pakhomov were studied. With addition of potassium iodide, a sixfold amount (compared with the initial) of iodine is liberated. Further, the liberated iodine is titrated by sodium thiosulfate. The authors find the degree of influence of a high nitrogen content on the determination of iodine in organic compounds. The procedure developed for the quantitative determination of the iodine in thyroidin by the combustion method is simple, fairly rapid, and can be used for the reliable control of the quality of thyroidin preparations and its starting raw material.

1986-11-01

236

Particle Detection with drift Chambers  

CERN Document Server

Particle Detection with drift Chambers

2008-01-01

237

Detection of basepair substitution mutation at a frequency of 1 x 10(-7) by combining two genotypic selection methods, MutEx enrichment and allele-specific competitive blocker PCR.  

Science.gov (United States)

The detection of rare mutations has many important applications, including risk assessment of drugs and chemicals, measuring environmental exposures to genotoxins, and cancer cell detection. A sensitive genotypic selection method has been developed that combines two different mutant allele selection techniques, MutEx enrichment and allele-specific competitive blocker PCR (ACB-PCR). This method was developed and evaluated for the detection of a CAA --> AAA mutation at codon 61 of the mouse H-ras gene. The MutEx enrichment is based on MutS binding to a mismatched basepair in heteroduplex DNA. The bound MutS protects the mutant allele from degradation during subsequent exonuclease treatment. ACB-PCR preferentially amplifies a mutant allele in a PCR reaction using a primer that has more mismatches to the wild-type allele than the mutant allele. By combining these two approaches, the ...

1998-01-01

238

Thermal NDE method for thermal spray coatings  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a feasibility demonstration of a thermal scanning NDE system for thermal spray coatings. Non-bonds were detected between several types of coatings and their substrates. Aluminum anti-skid coatings having very rough surfaces were included. A technique for producing known non-bond areas for calibrating and demonstrating NDE methods was developed.

1982-01-01

239

The different structural scales of the breast and their impact on time-of-flight and diffraction tomography  

Energy Technology Data Exchange (ETDEWEB)

Ultrasound tomography is an attractive imaging method for the detection of breast cancer. The complex anatomy of the breast with its different spatial scales and material property contrasts make accurate reconstructions very challenging. This paper proposes a hybrid approach whereby Travel-of-Flight and Diffraction Tomography are combined together to achieve high-resolution and high-accuracy sound-speed reconstructions. The method is validated with several numerical phantoms.

2010-01-01

240

Laser monitoring of the size and polarization of the gamma beams of #gamma##gamma# and e#gamma# colliders  

International Nuclear Information System (INIS)

It is proposed to measure the spot sizes and polarization of #gamma# beams of future #gamma#e and #gamma##gamma# colliders detecting e"+e"- pairs produced as a result of interaction of high energy #gamma# quanta with density modulated and not modulated laser photons. The quantum electrodynamics cross sections, necessary numerical results as well as a short comparison of the proposed method with some other methods are given. (orig.).

241

Instantaneous energy density as a feature for gear fault detection  

Science.gov (United States)

In this work, energy-based features for gear fault diagnosis and prediction are proposed. The instantaneous energy density is shown to obtain high values when defected teeth are engaged. Three methods are compared in terms of sensitivity, reliability and computation effectiveness. The Wigner Ville distribution is contrasted to the wavelet transform and the newly proposed empirical mode decomposition scheme. It is shown that all three methods are capable of a reliable prediction. An empirical law, which relates the energy content to the crack magnitude is established.

2006-07-01

242

Detection of acute myocardial infarction in spontaneously hypertensive rats by /sup 99m/Tc-Pyrrolidino methyl tetracycline  

Energy Technology Data Exchange (ETDEWEB)

The myocardial infarct induced by isoproterenol in spontaneously hypertensive rats accumulates higher activities of /sup 99/sup(m)Tc-PM tetracycline compared with the cardiac infarct in normotensive rats caused by the same method. The isoproterenol model of the myocardial necrosis was induced in intact rats without opening the thorax and is a convenient method for experimental radioisotope studies.

1983-01-01

243

Computer tomography used in tumour diagnosis in children  

Energy Technology Data Exchange (ETDEWEB)

Computer tomography used in the diagnosis of tumours is described in the light of particularly great diagnostic difficulties in children. Computer tomography was applied in 12 cases. A high diagnostic value of this method was demonstrated, which makes possible a more accurate diagnosis of the position of the tumour, its size, and expanding tendency. The possibility of estimating healthy tissues and organs, and those with pathological changes on the basis of differences in their density with a detection threshold at 0.5% density difference facilitates not infrequently preoperative diagnosis raising the value of the method.

1981-01-01

244

CT colonography. Virtual coloscopy; CT-Kolonographie. Virtuelle Koloskopie  

Energy Technology Data Exchange (ETDEWEB)

The CT colonography or virtual coloscopy is a new diagnostic method that allows the presentation of the whole colon using minimal invasive procedures. The method allows the detection of colorectal polyps and colorectal carcinomas. The book includes the following chapters: indications for CT colonography, diagnostic procedures, data processing and interpretation, diagnostic findings, preparation of the diagnostic result description and documentation, screening.

2009-07-01

245

Particle Swarm Optimization and gravitational wave data analysis: Performance on a binary inspiral testbed  

CERN Document Server

The detection and estimation of gravitational wave (GW) signals belonging to a parameterized family of waveforms requires, in general, the numerical maximization of a data-dependent function of the signal parameters. Due to noise in the data, the function to be maximized is often highly multi-modal with numerous local maxima. Searching for the global maximum then becomes computationally expensive, which in turn can limit the scientific scope of the search. Stochastic optimization is one possible approach to reducing computational costs in such applications. We report results from a first investigation of the Particle Swarm Optimization (PSO) method in this context. The method is applied to a testbed motivated by the problem of detection and estimation of a binary inspiral signal. Our results show that PSO works well in the presence of high multi-modality, making it a viable candidate ...

2010-01-01

246

Detection of 36 antibiotics in coastal waters using high performance liquid chromatography-tandem mass spectrometry  

British Library Electronic Table of Contents (United Kingdom)

Among pharmaceuticals and personal care products released into the aquatic environment, antibiotics are of particular concern, because of their ubiquity and health effects. Although scientists have recently paid more attention to the threat of antibiotics to coastal ecosystems, researchers have often focused on relatively few antibiotics, because of the absence of suitable analytical methods. We have therefore developed a method for the rapid detection of 36 antibiotic residues in coastal waters, including tetracyclines (TCs), sulfanilamides (SAs), and quinolones (QLs). The method consists of solid-phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis, using electrospray ionization (ESI) in positive mode. The SPE was performed with Oasis HLB and Oasi...

2011-01-01

247

Application of remote sensing and geophysics to the detection and monitoring of acid mine drainage  

Energy Technology Data Exchange (ETDEWEB)

The results of a study on the application of remote sensing and geophysical methods for the detection and monitoring of acid mine drainage (AMD) are summarized, with emphasis on those that appear most suitable. The study consisted of a literature review, an information survey of users and suppliers, and discussions with various experts. Space-borne sensors, airborne sensors, airborne videography and digital frame cameras, spectroradiometers, radar, and photographic data are considered. Geophysical methods are effective for measurement of sulphides, areas of active chemical oxidation, acid mine drainage, and contaminated ground water movement. The popularity and effectiveness of various geophysical methods are rated for AMD applications. 25 refs., 1 fig., 3 tabs.

1995-06-01

248

Absolute subcriticality measurement without calibration and detection efficiency dependence by the /sup 252/Cf source-driven noise method  

Energy Technology Data Exchange (ETDEWEB)

The /sup 252/Cf-source-driven noise analysis method determines the subcriticality of a system containing fissionable material from the ratio of cross power spectral densities between the detectors that detect particles from the fission process and between these detectors and an ionization chamber containing a spontaneously fissioning neutron source which provides neutrons to induce fission in the system. This method has two advantages: (1) a calibration is not required and thus subcriticality can be determined from measurements only on the subcritical system of interest, and (2) the subcriticality is independent of the type of detector or its efficiency. These properties of this technique are illustrated by measurements.

1984-01-01

249

A Study on TOFD Inspection Using Phased Array Ultrasonic Technique  

Energy Technology Data Exchange (ETDEWEB)

The techniques in order to measure the depth of defect in weldment and structure accurately have been developed. Many researches have made efforts to develop the methods for the accurate depth sizing of defect. TOFD is known as the most accurate method of various methods for measuring depth sizing. However, there is a possibility to miss defects because of the limitation of beam coverage for the ultrasound incident angle. In this study, the results for detectability and depth sizing using phased array ultrasonic technique for thick body were compared with those of conventional TOFD technique. It was experimentally confirmed that the phased array ultrasonic TOFD technique gives good detectability and accurate depth measurement for the various types of defects. The phased array ultrasonic TOFD technique developed in this study will contribute to increase the inspection reliability in ...

2005-08-15

250

A Laplacian approach to multi-oriented text detection in video.  

Science.gov (United States)

In this paper, we propose a method based on the Laplacian in the frequency domain for video text detection. Unlike many other approaches which assume that text is horizontally-oriented, our method is able to handle text of arbitrary orientation. The input image is first filtered with Fourier-Laplacian. K-means clustering is then used to identify candidate text regions based on the maximum difference. The skeleton of each connected component helps to separate the different text strings from each other. Finally, text string straightness and edge density are used for false positive elimination. Experimental results show that the proposed method is able to handle graphics text and scene text of both horizontal and nonhorizontal orientation. PMID:20733217

2011-02-01

251

Sensors and instrumentation for atmospheric pollutions control; Capteurs et instrumentation pour le controle des pollutions atmospheriques  

Energy Technology Data Exchange (ETDEWEB)

Reinforcement of the legislation concerning the emission of atmospheric pollutants, aerosols, refrigerants, solvents etc and the reduction of the greenhouse effect, has led to the development of performing instruments for the survey and control of ambient air quality and for the limitation of exhaust gases, combustion products, volatile organic compounds (VOC), particulates and noxious compounds in the atmosphere. This study is divided in 4 main parts. The first part describes the context of the air quality control: the problems linked with the environment and health, the pollutants characteristics, the pollution levels and the detection sensitivity of instruments according to the different type of pollutants (petroleum products, VOCs, ozone compounds, particulates, smells..), the protocols of air pollution measurements and their application (chimney smokes, industrial volatile compounds, indoor and ambient air ...

1996-11-01

252

Implant detectibility of intervertebral disc spacers in post fusion MRI: evaluation of the MRI scan quality by using a scoring system - an in vitro study  

International Nuclear Information System (INIS)

Intervertebral spacers for anterior spine fusion are made of different materials, such as titanium and cobalt chromium alloys and carbon fiber-reinforced polymers. Implant-related susceptibility artifacts can decrease the quality of MRI scans. The aim of this cadaveric study was to demonstrate the extent that implant-related MRI artifacting affects the postfusion differentiation of determined regions of interest (ROIs). In six cadaveric porcine spines, we evaluated the postimplantation MRI scans of a titanium, cobalt-chromium and carbon spacer that differed in shape and surface qualities. A spacer made of human cortical bone was used as a control. A defined evaluation unit was divided into ROIs to characterize the spinal canal as well as the intervertebral disc space. Considering 15 different MRI sequences read independently by an interobserver-validated team of specialists the artifact-affected image quality of the median ...

2007-02-01

253

Nondestructive techniques for the control of conditioned radioactive wastes  

International Nuclear Information System (INIS)

The final product of the radwaste conditioning process must satisfy certain requirments and physico-chemical properties in order to assure its safe long-term behaviour. Of course, the foreseen quality assurance and quality control should be conducted by means of non-destructive techniques. This work presents an over-view of various applicable non-destructive methods of analysis, showing their fields of investigation in testing waste packages, together with some arising practical problems. The most promising methods, such as eddy current testing, ultrasonic testing, #gamma#-scanning, #gamma#-spectroscopy, neutron counting and computerized tomography, are treated more deeply and some applications are presented. Particular attention is devoted to the development of a device based on computerized tomography; its essential components are reported and some design problems are also discussed.

2005-09-01

254

Automatic calculation of bathymetry for coastal hydrodynamic models  

British Library Electronic Table of Contents (United Kingdom)

A methodology is proposed to facilitate the construction of gridded bathymetry data for the use of hydrodynamic models on the continental shelf. It relies on the carrying out of three successive tasks: (1) automatic selection of records of better quality among multiple sets of overlapping data; (2) elimination of data points located on land; and (3) taking into account the shoreline as bathymetric data. Algorithms are proposed to perform sorting of the records according to their quality as well as masking by the coastline. The suggested method facilitates the updating of bathymetry data and optimizes their use. It enables automatic execution of all the tasks and building of new digital bathymetry models in a few hours, without action from the operator. The method has been tested many times...

2011-01-01

255

The mask detection technology for occluded face analysis in the surveillance system.  

Science.gov (United States)

The surveillance systems have been widely used in automatic teller machines (ATMs), banks, convenient stores, etc. For example, when a customer uses the ATM, the surveillance systems will record his/her face information. The information will help us understand and trace who withdrew money. However, when criminals use the ATM to withdraw illegal money, they usually block their faces with something (in Taiwan, criminals usually use safety helmets or masks to block their faces). That will degrade the purpose of the surveillance system. In previous work, we already proposed a technology for safety helmet detection. In this paper, we propose a mask detection technology based upon automatic face recognition methods. We use the Gabor filters to generate facial features and utilize geometric analysis algorithms for mask detection. The technology can give an early warning to save-guards when any "customer" or ...

2005-05-01

256

Monitoring report of groundwater quality in and around the former Yotsugi open-pit mining site, Ningyo-toge, Okayama, Japan  

Energy Technology Data Exchange (ETDEWEB)

Monitoring of groundwater quality from boreholes in and around the former Yotsugi open-pit mining site in the Ningyo-toge Environmental Engineering Center, JNC, have been carried out to estimate extent and quality of contaminated water plume from the buried heap-leaching residue. In this report, data collected from 1979 to 1998 fiscal year were listed and their spatial and time variation of physicochemical parameters, uranium and radium were also summarized. Additionally, groundwater sampler has been improved and analytical method has been modified. Some results from groundwater quality were; 1. Generally, electric conductivity and concentrations of uranium and radium outside of the site tend to lower than one from the inside area. 2. Data from borehole No. 13, installed outside of the site, exceptionally little higher than one from the inside area. (author)

1999-08-01

257

Exploration of exposure dose optimization for pelvic examination in direct digital radiography with a phantom  

International Nuclear Information System (INIS)

Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly different. Conclusion: The image quality of direct digital radiography system is improved as ...

2005-10-01

258

MRI in preoperative evaluation of chronic paranasal sinusitis - a comparison with CT; MRT in der praeoperativen Diagnostik der chronischen Sinusitis im Vergleich mit der CT  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To determine the value of MRI in the preoperative evaluation of chronic paranasal sinusitis and to compare the results with CT and intraoperative findings. Method/Materials: 42 patients with clinical signs of chronic paranasal sinusitis underwent MRI after CT evaluation on one day, with subsequent functional endoscopic sinus surgery on the next day. Coronary CT was obtained with 5-mm slices and table-feed in the prone position, while MRI was performed in the supine position with coronary T{sub 2}-TSE+pd and coronary and transverse HASTE, each with 5-mm slice thickness. Aquisition time in MRI was less than 8 minutes. Two radiologists reviewed the CT and MRI scans for signs of sinusitis and detection of anatomical landmarks. The results were correlated with the intraoperative findings. Results: MRI offered no artifacts of dental work and showed more often high quality pictures than CT. CT and MRI demonstrated a good ...

2001-04-01

259

Imaging techniques for the injured ankle joint and tarsal bones  

International Nuclear Information System (INIS)

In the case of injuries of the ankle joint, an imaging technique is expected to reveal the state of the bones, ligaments, and articular cartilage. Irrespective of novel imaging techniques, a plain radiography will be made in order to obtain a first picture of the injury. Examples are given, showing that further orientation along the Lauge-Hansen classification scheme of this type of injury helps to completely ascertain the damage to the Articulatio talocruralis. Further examinations applying specific methods such as arthrography will detect possible, isolated syndesmosis ruptures; lesions of the ligaments can also be directly detected by CT or MRT. The articular cartilage and its lesions can be visualized by a combination of CT and arthrography, but are better shown by the completely non-invasive MRT. This latter method also gives insight into pathological processes with the bone. It allows to ...

260

The interpolation damage detection method for frames under seismic excitation  

Science.gov (United States)

In this paper a new procedure, addressed as Interpolation Damage Detecting Method (IDDM), is investigated as a possible mean for early detection and location of light damage in a structure struck by an earthquake. Damage is defined in terms of the accuracy of a spline function in interpolating the operational mode shapes (ODS) of the structure. At a certain location a decrease (statistically meaningful) of accuracy, with respect to a reference configuration, points out a localized variation of the operational shapes thus revealing the existence of damage. In this paper, the proposed method is applied to a numerical model of a multistory frame, simulating a damaged condition through a reduction of the story stiffness. Several damage scenarios have been considered and the results indicate the effectiveness of the method to assess and localize damage for the case of concentrated damage ...

2011-10-01

261

Results of UT training for defect detection and sizing technique using specimens with fatigue crack and SCC  

International Nuclear Information System (INIS)

At the importance increase of UT (ultrasonic testing) with the application of rules on fitness-for-service for nuclear power plants, JAPEIC (Japan power engineering and inspection corporation) started education training for defect detection and sizing technique. Weld joints specimen with EDM (Electro-Discharged Machining) notches, fatigue cracks and intergranular stress corrosion cracks were tested and practiced repeatedly based on a modified ultrasonic method and the defect size measuring accuracy of the trainees was surely improved. Results of the blind test confirmed effectiveness of education training. (T. Tanaka)

2005-04-01

262

On the Generation of a Robust Residual for Closed-loopControl systems that Exhibit Sensor Faults  

DEFF Research Database (Denmark)

This paper presents a novel design methodology, based on shaping the system frequency response, for the generation of an appropriate residual signal that is sensitive to sensor faults in the presence of model uncertainty and exogenous unknown (unmeasured) disturbances. An integrated feedback controller design and robust frequency-based fault detection approach is proposed for Single-Input/Single-Output systems. The effciency of the proposed method is demonstrated on a Single Machine Innite Bus (SMIB) power system that achieves a coordinate power system stabilizer with satisfactory sensor fault detection capabilities.

2007-01-01

263

Method for limiting scram discharge water  

International Nuclear Information System (INIS)

Object: To limit the discharge amount of reactor water in a primary system at the time of scram to prevent excessive outflow of reactor water outside the system. Structure: A signal from an upper limit position indicator detects the fact that control rods are completely inserted when the reactor is urgently stopped and the detection signal causes a valve in an outflow line of the discharge water from a control rod driving mechanism to be closed to limit the amount of discharge flown into the scram discharge vessel, thus preventing outflow of reactor water in the primary system after the scram has been initiated. (Kamimura, M.).

264

Leak detection on petroleum pipelines  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a unique method, currently under evaluation, that can continuously track pipeline operation providing essentially instantaneous responses to leaks or ruptures without causing a pressure drop or energy loss. Using the highly linear characteristics of a very accurate and repeatable meter and then correlating it to a second identical unit, a dynamic leak detection system is planned that can be retrofitted on existing pipelines without a major construction effort nor destroying the integrity of the existing transmission line. Initial tests performed on a crude oil transmission line verified the equipment's performance and established that the repeatability limits are sufficient to continue development of the concept.

1984-04-01

265

Generation and detection of superstrong shock waves during ablation of an aluminum surface by intense femtosecond laser pulses  

British Library Electronic Table of Contents (United Kingdom)

Superstrong shock waves of multimegabar level generated during ablation of an aluminum surface by intense (<1 PW/cm2) femtosecond laser pulses have been detected by observing the propagation of a shock wave in air from the ablated surface to a broadband piezoelectric receiver. The estimated initial pressure and velocity of the shock wave (ablation plume) agree well with data obtained earlier by various methods for shock waves propagating inside ablated targets.

2011-01-01

266

Accurate determination of detection efficiency and self-absorption factors in measuring radon daughter  

International Nuclear Information System (INIS)

The detection efficiency of #alpha# particles of "2"1"4Po 7.69 MeV and "2"1"8Po 6.00 MeV in measuring radon daughters were determined through the data which were measured with long-lived #alpha# standard source and radon daughter standard source and with curve-fitting method of general formulation. The indeterminacy was #<=#2.5% and #<=#2.7% respectively. Their ranges in filter membrane were also determined, and the effect of the indeterminacy on the self-absorption factors was #<=#1.3%.

267

A Grafcet-based expert system for process control; Un systeme expert base sur le Grafcet pour le controle de procede  

Energy Technology Data Exchange (ETDEWEB)

This article describes a hierarchical and functional model for continuous process control aid. The expertise is represented by graphs from a simple functional restructuring of the Grafcet, which is the formalism used by the designers of the command-control program. The new structure is familiar to the operator, and it is settled in an expert system. The application built on the basis of this method detects some default types which are not detected by the control-command. It proposes a diagnosis to the operator, and can explain and justify the state of the process. (authors) 9 refs.

1997-11-01

268

One-step RNA pathogen detection with reverse transcriptase activity of a mutated thermostable Thermus aquaticus DNA polymerase  

British Library Electronic Table of Contents (United Kingdom)

We describe the cloning and characterization of a mutated thermostable DNA polymerase from Thermus aquaticus (Taq) that exhibits an increased reverse transcriptase activity and is therefore designated for one-step PCR pathogen detection using established real-time detection methods. We demonstrate that this Taq polymerase mutant (Taq M1) has similar PCR sensitivity and nuclease activity as the respective Taq wild-type DNA polymerase. In addition, and in marked contrast to the wild-type, Taq M1 exhibits a significantly increased reverse transcriptase activity especially at high temperatures (>60degreeC). RNA generally hosts highly stable secondary structure motifs, such as hairpins and G-quadruplexes, which complicate, or in the worst case obviate, reverse transcription (RT). Thus, RT at hi...

2010-01-01

269

Identification and staging of bladder carcinoma  

International Nuclear Information System (INIS)

The purpose of the present study was to compare the effectiveness of MRI, CT and radioimmunoscintigraphy in the staging and detection of bladder cancers in 28 patients. We distinguish two groups: Group I included the tumour stages CIS-T_3_A and the second group the deep infiltrative tumours T_3_B-T_4. MRI was slightly superior to CT in respect of tumour staging (75% correct results as compared to 63%). No understaging occurred with MRI, whereas in 22% of the cases the stage of the tumour was underestimated using CT diagnostics. Overstaging occurred in 25% of the MRI and 15% of the CT-diagnostics, respectively. RIS cannot distinguish the tumour groups, and hence this method is useful only for the detection of the primary tumour and metastases. In 77% of cases the tumour was detected and in 15% the tumour could be safely excluded. (orig.).

270

Fault detection and diagnosis of a gearbox in marine propulsion systems using bispectrum analysis and artificial neural networks  

British Library Electronic Table of Contents (United Kingdom)

A marine propulsion system is a very complicated system composed of many mechanical components. As a result, the vibration signal of a gearbox in the system is strongly coupled with the vibration signatures of other components including a diesel engine and main shaft. It is therefore imperative to assess the coupling effect on diagnostic reliability in the process of gear fault diagnosis. For this reason, a fault detection and diagnosis method based on bispectrum analysis and artificial neural networks (ANNs) was proposed for the gearbox with consideration given to the impact of the other components in marine propulsion systems. To monitor the gear conditions, the bispectrum analysis was first employed to detect gear faults. The amplitude-frequency plots containing gear characteristic sign...

2011-01-01

271

False discovery rate: setting the probability of false claim of detection  

CERN Document Server

When testing multiple hypothesis in a survey --e.g. many different source locations, template waveforms, and so on-- the final result consists in a set of confidence intervals, each one at a desired confidence level. But the probability that at least one of these intervals does not cover the true value increases with the number of trials. With a sufficiently large array of confidence intervals, one can be sure that at least one is missing the true value. In particular, the probability of false claim of detection becomes not negligible. In order to compensate for this, one should increase the confidence level, at the price of a reduced detection power. False discovery rate control is a relatively new statistical procedure that bounds the number of mistakes made when performing multiple hypothesis tests. We shall review this method, discussing exercise applications to the field of gravitational wave surveys.

2005-01-01

272

Ergosterol analyses of oil palm seedlings and plants infected with Ganoderma  

British Library Electronic Table of Contents (United Kingdom)

Basal stem rot of oil palm (OP) by Ganoderma boninense is of major economic concern and it is the predominant disease of OP in SE Asia. Also, other plantation crops are affected by Ganoderma. The early detection of symptoms is crucial for control, although effective methods remain elusive. Ergosterol is the principal sterol of fungi and plays an essential role in the cell membrane and other cellular constituents. The analysis of ergosterol is useful for fungal detection in solid plant substrates. The present report compares ergosterol concentration in sound and decayed OP seedlings and mature plants using HPLC with diode array detection. The disease of OP requires to be considered as a white rot process where fungal biomass will increase from a low to high level as the infection progresses...

2011-01-01

273

Direct detection of Salmonella without pre-enrichment in milk, ice-cream and fruit juice by PCR against hilA gene  

British Library Electronic Table of Contents (United Kingdom)

A novel PCR based assay was devised to specifically detect contamination of any Salmonella serovar in milk, fruit juice and ice-cream without pre-enrichment. This method utilizes primers against hilA gene which is conserved in all Salmonella serovars and absent from the close relatives of Salmonella. An optimized protocol, in terms time and money, is provided for the reduction of PCR contaminants from milk, ice-cream and juice through the use of routine laboratory chemicals. The simplicity, efficiency (time taken 3-4 h) and sensitivity (to about 5-10 CFU/ml) of this technique confers a unique advantage over other previously used time consuming detection techniques. This technique does not involve pre-enrichment of the samples or extensive sample processing, which was a pre-requisite in mos...

2012-01-01

274

Diagnostic and Prognostic Utility of t(14;18) in Follicular Lymphoma  

British Library Electronic Table of Contents (United Kingdom)

Abstract Background: Follicular lymphoma (FL) is one of the most common non-Hodgkin's lymphomas of B cells, being closely associated with a t(14;18) translocation. Detection of t(14;18), which is present in 70-95% of FL, might aid in FL diagnosis. Objective: To compare the efficacy of routine polymerase chain reaction (PCR) and fluorescence in situ hybridization (FISH) techniques in detecting t(14;18) in paraffin-embedded tissue samples of FL patients at different stages. Combined with other immunophenotypic biological determinants, detection of t(14;18) might help to determine patients at increased risk according to the FL International Prognostic Index (FLIPI) and therefore facilitate appropriate treatment. Design and Methods: This study was mainly based on a retrospective examination of...

2007-01-01

275

Determination of low-molecular-weight organic acids and inorganic anions by gradient elution chromatography  

Energy Technology Data Exchange (ETDEWEB)

Conditions of the separation and detection of organic and inorganic anions by gradient ion chromatography and suppressed conductivity detection were studied, and the procedure of gradient elution was optimized. A detection limit of 1 x 10{sup -3} {mu}g x L{sup -1} was obtained using the pre-concentrated column and most relative standard deviations obtained in the determination of seven organic and inorganic anions were below 5%. This method was proved to be simple, rapid and accurate for the separation and determination of low-molecular-weight organic acids and inorganic anions and could be applied in the analysis of the samples from water and steam systems of thermal power plants with satisfactory results. (orig.)

2007-03-15

276

Detecting hot spots at hazardous-waste sites  

Energy Technology Data Exchange (ETDEWEB)

Evaluating the need for remedial cleanup at a waste site involves both finding the average contaminant concentration and identifying highly contaminated areas, or hot spots. A nomographic procedure to determine the sample configuration needed to locate a hot spot is presented. The technique can be used to develop a waste-site sampling plant - to determine either the grid spacing required to detect a hot spot at a given level of confidence, or the probability of finding a hot spot of a certain size, given a particular grid spacing. The method and computer program (ELIPGRID) were developed for locating geologic deposits, but the basic procedure can also be used to detect hot spots at chemical- or nuclear-waste disposal sites. Nomographs based on the original program are presented for three sampling-grid configurations - square, rectangular and triangular.

1984-07-09

277

A Comprehensive Survey of Data Mining-based Fraud Detection Research  

CERN Document Server

This survey paper categorises, compares, and summarises from almost all published technical and review articles in automated fraud detection within the last 10 years. It defines the professional fraudster, formalises the main types and subtypes of known fraud, and presents the nature of data evidence collected within affected industries. Within the business context of mining the data to achieve higher cost savings, this research presents methods and techniques together with their problems. Compared to all related reviews on fraud detection, this survey covers much more technical articles and is the only one, to the best of our knowledge, which proposes alternative data and solutions from related domains.

2010-01-01

278

Marketers report on oil quality  

Energy Technology Data Exchange (ETDEWEB)

The quality of fuel oils is discussed. The problems that the fuel oil marketer must deal with that relate to the quality of the fuel oil are described.

1985-04-01

279

Method for syndrome coding and its application to fast hardware data selection based on the processors operating in the GF(2sup(m)) Galois field  

International Nuclear Information System (INIS)

The method of syndrome coding for data compression read out from multiwire proportional chambers that has been previously proposed is generalized in case of its application to registration of the coordinates of events detected. The questions of execution of arithmetic and algebraic operations on the Galois field elements and their hardware implementation are considered. The method of computation is presented of a specialized processor for parallel computing the coordinates of three sparks. The estimate of its speed is equal to 185 ns. Data compression, data selection and coordinate calculations are performed without use of memory elements and timing pulses.

280

Fundamentals for remote structural health monitoring of wind turbine blades - a pre-project. Annex B - Sensors and non-destructive testing methods for damage detection in wind turbine blades  

Energy Technology Data Exchange (ETDEWEB)

This annex provides a description of the sensor schemes and the non-destructive testing (NDT) methods that have been investigated in this project. Acoustic emission and fibre optic sensors are described in some detail whereas only the key features of well-established NDT methods are presented. Estimates of the cost of different sensor systems are given and the advantages and disadvantages of the different schemes is discussed. (au)

2002-05-01

281

Coverage and large scale anisotropies estimation methods for the Pierre Auger Observatory  

Energy Technology Data Exchange (ETDEWEB)

When searching for anisotropies in the arrival directions of Ultra High Energy Cosmic Rays, one must estimate the number of events expected in each direction of the sky in the case of a perfect isotropy. We present in this article a new method, developed for the Auger Observatory, based on a smooth estimate of the zenith angle distribution obtained from the data itself (which is essentially unchanged in the case of the presence of a large scale anisotropy pattern). We also study the sensitivity of several methods to detect large-scale anisotropies in the cosmic ray arrival direction distribution : Rayleigh analysis, dipole fitting and angular power spectrum estimation.

2005-07-01

282

Analytical methods for heavy metals in herbal medicines  

British Library Electronic Table of Contents (United Kingdom)

Abstract Introduction - It is estimated that about 70-80% of the world's population relies on non-conventional medicine, mainly of herbal origin. However, owing to the nature and sources of herbal medicines, they are sometimes contaminated with toxic heavy metals such as lead, arsenic, mercury and cadmium, which impose serious health risks to consumers. It is critical to analyse source materials for heavy metals in order to ensure that their concentrations meet the related standards or regulations limiting their concentrations in herbal medicines. In this review, different analytical methods for analysis of heavy metals in herbal medicines are discussed. Objective - To provide a comprehensive review of the current state of the art in analytical methods used to detect heavy metals in herbal...

2011-01-01

283

An optical fiber methane sensing system employing a two-step reference measuring method  

British Library Electronic Table of Contents (United Kingdom)

An optical fiber methane sensing system utilizing a super-luminescent diode (SLD) in the 1.33-mm band and a fiber Fabry-Perot tunable filter (FFP-TF) is developed. A two-step reference measuring method, which is based on differential absorption technique, is employed; a reference channel is introduced to eliminate the fluctuation of the illuminant spectrum, and the reference wavelength acquired by tuning the FFP-TF is introduced to eliminate the environmental influence. The two-step reference measuring method has improved the reliability and stability of the system. A minimum detectable methane concentration of 0.3% has been experimentally achieved.

2008-01-01

285

Assessment of soil-gas, soil, and water contamination at the former 19th Street landfill, Fort Gordon, Georgia, 2009-2010  

Science.gov (United States)

Soil gas, soil, and water were assessed for organic and inorganic constituents at the former 19th Street landfill at Fort Gordon, Georgia, from February to September 2010. Passive soil-gas samplers were analyzed to evaluate organic constituents in the hyporheic zone and flood plain of a creek and soil gas within the estimated boundaries of the former landfill. Soil and water samples were analyzed to evaluate inorganic constituents in soil samples, and organic and inorganic constituents in the surface water of a creek adjacent to the landfill, respectively. This assessment was conducted to provide environmental constituent data to Fort Gordon pursuant to requirements of the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. The passive soil-gas samplers deployed in the water-saturated hyporheic zone and flood plain of the creek adjacent to the former landfill indicated the presence of total petroleum hydrocarbon (TPH) and octane above ...

2011-01-01

286

Computed tomography of the thorax: a status report  

Energy Technology Data Exchange (ETDEWEB)

Computed tomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computed tomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. ...

1981-11-01

287

Computed tomography of the thorax: a status report  

International Nuclear Information System (INIS)

Computed tomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computed tomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. ...

288

Process-integrated online monitoring of safety-relevant aluminum airbag pressure vessel components for a combined defect detection and material property determination by using contactless NDT (EMUS and EC)  

Energy Technology Data Exchange (ETDEWEB)

Airbag pressure vessels for the north-American market mainly are made by forging and by the use of steel alloys. In Europe aluminum alloys are common and the manufacturing process is extrusion of circular blanks - made from cold rolled plates - in a form applying a 100 t press at room temperature. Then by heat treatment the strength/hardness of the material is properly adjusted and after that the pressure vessel parts have to be continuously inspected with an inspection and handling cycle time of 3 s. Inspection of the axis-symmetric parts is asked for surface breaking extrusion defects as well as for surface parallel delaminations in the bulk volume. Furthermore, the material strength is a quality characteristic that has to be nondestructively registered and documented. The inspection is performed by eddy current probes and an EMAT, of which the eddy current impedance measurements are used for surface breaking extrusion defect detection and ...

1999-07-01

289

The influence of different SPECT reconstruction algorithms on cardiac ischemia with the use artificial neural networks  

International Nuclear Information System (INIS)

The aim of the study was the attempt to evaluate the influence of two different methods of cardiac perfusion SPECT reconstruction (FBP and ITW) on clinical efficacy in diagnosing the coronary artery disease as well as the cardiac ischemia detection in three areas of heart vascularized by main coronary arteries: LAD, LCX and RCA with the use of artificial neural networks (ANN). The study was performed retrospectively with the use of the diagnostic image records as well as clinical dataset of 43 patients. Myocardial perfusion stress/rest SPECT study and X-ray coronarography data were evaluated for each patient. The results of coronary angiography were considered the reference method. The cardiac SPECT data were reconstructed using the two different methods: filtered backprojection (FBP) and iterative Wallis method (ITW). The local perfusion deficits denominated in stress and rest ...

290

Waveguide device and method for making same  

Energy Technology Data Exchange (ETDEWEB)

A monolithic micromachined waveguide device or devices with low-loss, high-power handling, and near-optical frequency ranges is set forth. The waveguide and integrated devices are capable of transmitting near-optical frequencies due to optical-quality sidewall roughness. The device or devices are fabricated in parallel, may be mass produced using a LIGA manufacturing process, and may include a passive component such as a diplexer and/or an active capping layer capable of particularized signal processing of the waveforms propagated by the waveguide.

2007-08-14

291

Transbrachial arterial digital subtraction angiography  

International Nuclear Information System (INIS)

27 cases including 7 outpatients, underwent intraarterial DSA using 4-F nylon catheter, by transbrachial arterial approach. Much of DSAs were performed in Fuji Computed Radiography (FCR), which has high spatial resolution. In all cases, image quality satisfied clinical demands. No major complication occured in this series. Transbrachial arterial digital subtraction angiography is excellent and safe method for screening of vascular disease. (author).

1985-01-01

292

Thermal fatigue failure at the White Cliffs solar thermal power plant  

Energy Technology Data Exchange (ETDEWEB)

The failure of receivers has been one of the main operating problems at the White Cliffs solar thermal power plant. This Technical Note reports the results of an initial investigation that identifies the cause as having been their thermal fatiguing of the tube walls. The fatigue appears to be caused by unstable heat transfer at vapor qualities below the point where critical heat flux is generally exceeded. Methods for avoiding this problem are tested.

1995-02-01

293

New standard environmental management  

International Nuclear Information System (INIS)

The ISO 14001:2004 standard, like ISO 9001:2000 on quality management, transcends the preventive approach (based on a rigid and more or less adequate process-management model still mainly inspired by traditional production methods) and introduces in its stead a highly flexible approach applicable to any socio-economic activity. It is structured by processes rather than system elements, and is based on the quest for efficacy and ongoing improvement.

294

Neutron radiography with the cyclotron, 6  

International Nuclear Information System (INIS)

The image processing system for the dynamic neutron radiography has been developed. It is based on the hardware subset, composed by the method of the pipe-line and use of algorithm of local statistics. The processing speed per one pixel is shorter than 100 n sec and video-rate processing can be executed on it. Some image processes for improving the quality of the real-time neutron image, noise reduction and contrast stretching would be attempted by the use of this system. (author).

1988-01-01

295

Dose specification and quality assurance of RTOG protocol 95-17; a cooperative group study of 192Ir breast implants as sole therapy  

UK PubMed Central (United Kingdom)

PurposeRTOG protocol 95-17 was a phase I/II trial to evaluate multi-catheter brachytherapy as the sole method of adjuvant breast radiotherapy for stage I/II breast...Full Text Available

2007-12-01

296

Development document for proposed effluent limitations guidelines and standards for the transportation equipment cleaning category  

Energy Technology Data Exchange (ETDEWEB)

Contents of this report are under the following topical sections: Legal Authority; Summary and Scope; Data Collection Activities; Industry Description; Industry Subcategorization; Water Use and Wastewater Characterization; Pollutants Selected for Regulation; Pollution Prevention and Wastewater Treatment Technologies; Development of Control and Treatment Options; Costs of Technology Bases for Regulations; Pollutant Reduction Estimates; Non-Water Quality Impacts; Implementation of Proposed Effluent Limitation Guidelines and Standards; Analytical Methods; and Glossary.

1998-05-01

297

Absorbed dose and dose equivalent depth distributions for protons with energies from 2 to 600 MeV  

Energy Technology Data Exchange (ETDEWEB)

Depth dose distributions for protons in the energy range from 2 to 600 MeV have been calculated by Monte Carlo and analytical methods. The dependence on energy of Maximum Dose Equivalent (MDE), quality factor and isotropic factor recommended for practical use are presented. The problems connected with regulation of maximum permissible proton fluxes are discussed. (author).

1989-01-01

298

Statistical methods for environmental pollution monitoring  

Energy Technology Data Exchange (ETDEWEB)

This volume covers planning, design, and data analysis. It offers statistical methods for designing environmental sampling and monitoring programs as well as analyzing the resulting data. Statistical sample survey methods to problems of estimating average and total amounts of environmental pollution are presented in detail. The book also provides a broad array of statistical analysis methods for many purposes...numerous examples...three case studies...end-of-chapter questions...computer codes (showing what output looks like along with its interpretation)...a discussion of Kriging methods for estimating pollution concentration contours over space and/or time...nomographs for determining the number of samples required to detect hot spots with specified confidence...and a description and tables for conducting Rosner's test to identify outlaying (usually large) pollution ...

1986-01-01

299

Evaluation of the Curve-fitting method and the Horner-plot method for estimation of the true formation temperature using temperature recovery logging data  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the method to estimate the true formation temperature using temperature recovery logging data after the well reach to total depth (T.D.). The method designated as ''Curve-fitting method (CFM)'' is based on mathematical model proposed by Middleton (1979, 1982). The accuracy and applicability of this method are evaluated with several field data and compared advantageously with the Horner-plot method. Then, real-time data acquisition system including interpretation software has also been successfully developed. As a conclusion, the followings are confirmed: (1) The developed CFM can be applicable to the estimation of the true formation temperature even using 24 hours temperature recovery data, although the Horner-plot method might need up to 120 hours recovery data, usually. (2) Though depending upon the ...

1995-01-26

300

Rapid vegetative propagation of conifers  

Energy Technology Data Exchange (ETDEWEB)

Factors influencing the rooting-potential of stem cuttings of conifers were studied for the purpose of improving methods of rapid vegetative propagation. Within the bounds of hereditary limits, root regeneration depends, to a considerable extent, on the qualities of rooting-media, date of cutting excision, age and physiological conditions of the stock plant, age of the cutting-wood, its position on the plant, and chemical treatment. Hardwood cuttings, which have a relatively high content of endogenous auxin and carbohydrates, and morphological root initials, gave the best results. This method made it possible to increase the growth rate of cuttings 2.5-5 times that of cuttings taken from shoots of current growth. (Refs. 21).

1981-04-01

301

Laboratory robotics systems at the Savannah River Laboratory  

International Nuclear Information System (INIS)

Many analytical chemistry methods normally used at the Savannah River site require repetitive procedures and handling of radioactive and other hazardous solutions. Robotics is being investigated as a method of reducing personnel fatigue and radiation exposure and also increasing product quality. Several applications of various commercially available robot systems are discussed involving cold (nonradioactive) and hot (radioactive) sample preparations and glovebox waste removal. Problems encountered in robot programming, parts fixturing, design of special robot hands and other support equipment, glovebox operation, and operator-system interaction are discussed. A typical robot system cost analysis for one application is given.

1983-11-16

302

In situ monitoring of grouted electrolytes  

Energy Technology Data Exchange (ETDEWEB)

Cement-based composites are widely used in applications which demand long-term service life. One important example is in immobilization matrices for low-level radioactive and other hazardous wastes, which demands long-term retention and durability. The authors describe conductivity measurements of grouts flooded with water and in contact with a sink that consists of pure water. The conductivity measurements were designed and carried out in parallel with present quality verification methods and standard leach tests of the nuclear waste management industry. For the first time, the authors show that the method of replacing intrusive chemical analysis with conductivity measurements of the leaching samples yields equivalent results.

1996-04-01

303

A Bayesian hierarchical approach to dual response surface modelling  

British Library Electronic Table of Contents (United Kingdom)

In modern quality engineering, dual response surface methodology is a powerful tool to model an industrial process by using both the mean and the standard deviation of the measurements as the responses. The least squares method in regression is often used to estimate the coefficients in the mean and standard deviation models, and various decision criteria are proposed by researchers to find the optimal conditions. Based on the inherent hierarchical structure of the dual response problems, we propose a Bayesian hierarchical approach to model dual response surfaces. Such an approach is compared with two frequentist least squares methods by using two real data sets and simulated data.

2011-01-01

304

Testing of abrasion materials  

Energy Technology Data Exchange (ETDEWEB)

A method of abrasion testing according to ASTM C 704-76 a is presented for steel fibre concrete mortar, fusion-cast basalt and a surface coating material and results of practical interest are mentioned. Due to the high technical demands on these materials and their specific fields of application, the very first test already supplied interesting findings. From the user's point of view, the method is an interesting alternative to the common test methods, e.g. according to DIN 52 108 (wheel test according to Boehme). In English-speaking countries, testing according to ASTM is often mandatory in the refractory industry in order to assure constant quality of refractory materials after setting. The method is characterized by good comparability and high accuracy of measurement. Only the test piece is exchanged while the test conditions remain constant, so that accurate information ...

1983-06-01

305

Rough surface  

International Nuclear Information System (INIS)

For the determination of the thermal-hydraulic performances of rough surfaces, the method of evaluation is particularly important. In order to increase confidence in the results, a new evaluation procedure was introduced. This procedure is based on the transformation of simple channel experimental results to equal boundary conditions, and on the suitable application and confirmation of these transformed values in more complicated flow channel geometries. Existing methods, applied to the results obtained in an annular channel, do not fulfil all the transformation requirements. Thus a new, more complete transformation method, which uses the turbulent eddy diffusivity model, was developed. To check the quality of this transformation, within the scope of the new evaluation procedure, the results of experimental investigation in annular channels and in a bundle of hexagonal geometry were used together with ...

2009-08-01

306

Computer Aided Optimization of the Unconventional Processing  

CERN Document Server

The unconventional technologies, currently applied at a certain category of materials, difficult to be processed through usual techniques, have undergone during the last 60 years all the stages, since their discovery to their use on a large scale. They are based on elementary mechanisms which run the processing through classic methods, yet, they use in addition the interconnections of these methods. This leads to a plus in performance by increasing the outcomes precision, reducing the processing time, increasing the quality of the finite product, etc. This performance can be much increased by using the computer and a software product in assisting the human operator in the processing by an unconventional method such as; the electric or electro-chemical erosion, the complex electric-electro-chemical erosion, the processing by a laser fascicle and so on. The present work presents such an application based ...

2009-01-01

307

Combined migration velocity model-building and its application in tunnel seismic prediction  

Science.gov (United States)

We propose a combined migration velocity analysis and imaging method based on Kirchhoff integral migration and reverse time migration, using the residual curvature analysis and layer stripping strategy to build the velocity model. This method improves the image resolution of Kirchhoff integral migration and reduces the computations of the reverse time migration. It combines the advantages of efficiency and accuracy of the two migration methods. Its application in tunnel seismic prediction shows good results. Numerical experiments show that the imaging results of reverse time migration are better than the imaging results of Kirchhoff integral migration in many aspects of tunnel prediction. Field data show that this method has efficient computations and can establish a reasonable velocity model and a high quality imaging section. Combination with geological information can make an ...

2010-09-01

308

Application of nuclear analytical methods in determining heavy metals in a welder's working environment  

International Nuclear Information System (INIS)

The problems are discussed of using radionuclide X-ray fluorescence analysis (the most frequently used source is "2"4"1Am) and neutron activation analysis for monitoring the chemical quality of the working environment of a welder. Elements determinable by these methods are listed and the advantages of the methods stated with regard to speed, simplicity and appropriate accuracy of measurement together with commercial availability of the instruments. Welding as a source of harmful substances is assessed by determination of the amount of chromium in aerosols generated by welding austenitic chromium-nickel steels. The described methods allow to obtain a complex image of the chemical nature of welding aerosols and to understand the mechanism of their impact on the human organism. (J.C.).

1986-01-01

309

Radiogauging to investigate two phase flow. Graduation report  

Energy Technology Data Exchange (ETDEWEB)

New measuring methods are developed and are tested with the small reactor simulator MIDAS (Mini Dodewaard ASsembly). The purpose of this work is to be able to measure accurately as many different properties of the flow as possible in the coming bigger simulator SIDAS (Simulated Dodewaard ASsembly). In SIDAS the flow around a fuel assembly of the Dutch Dodewaard reactor will be simulated. An extensive evaluation of the gamma detection system showed that the detection system could be simplified strongly. The simplified system is used to measure the radial and axial distribution of the void fraction in the core of MIDAS for three different operating conditions. Two new measuring methods have been developed and tested. A method to estimate the probability density of the void fraction in time. Due to the nonlinear relation between transmission and void fraction the determined average ...

1992-11-12

310

Development of a leak location system for use on underground electric power transmission cable. Final report  

Energy Technology Data Exchange (ETDEWEB)

This report describes a study to evaluate methods for locating leaks of dielectric fluid from buried high-voltage cable systems. Two primary types of leak location systems were investigated: (1) systems that will rapidly isolate the leak within a manhole section, typically 1000-m long on a feeder that might be 30-km long; and (2) systems that will then pinpoint the location of the leak. Rapid leak isolation was accomplished by developing an enhanced conductivity oil probe which allows the injection of a small quantity of conductive oil and which indicates the path of the oil as it drifts downstream in the direction of the leak. Two methods for pinpointing the leak were proven. The more successful method was the use of trained leak location dogs which were found to have far better sensitivity than instruments and which could detect cable oil alone without the need for additives. A tracer gas injection ...

1982-10-01

311

Large-scale production of single-walled carbon nanotubes by induction thermal plasma  

International Nuclear Information System (INIS)

High quality single-walled carbon nanotubes (SWNT) have been synthesized at large scales by the method of direct evaporation of carbon black and metallic catalyst mixtures, using induction thermal plasma technology. The processing system consists mainly of an RF plasma torch, which generates a plasma jet of extremely high temperature (?15 000 K), with a high energy density and abundance of reactive species (ions and neutrals). With the present reactor system, it has been demonstrated that carbon soot product which contains approximately 40 wt% of SWNT can be continuously synthesized at the high production rate of ?100 g h-1. The processing parameters involved have been examined closely in order to evaluate their individual influences on SWNT synthesis. The results have shown that the quality and purity of the SWNT produced are critically affected by the grade of carbon black, the plasma gas composition and the metallic ...

2007-04-21

312

Development of food preservation and processing techniques by radiation  

International Nuclear Information System (INIS)

Development of food preservation and processing techniques by radiation was performed. Gamma irradiation at 2-10 kGy is considered to be an effective method to control pathogenic bacteria in species including Escherichia coli O157:H7. Gamma irradiation at 5 kGy completely eliminated pathogenic bacteria in beef. Gamma irradiation at such doses and subsequent storage at less than 4 deg C could ensure hygienic quality and prolong the microbiological shelf-life resulting from the reduction of spoilage microorganisms. Gamma irradiation on pre-rigor beef shortens the aging-period, improves tenderness and enhances the beef quality. And, a new beef processing method using gamma irradiation, such as in the low salt sausage and hygienic beef patty was developed. Safety tests of gamma-irradiated meats(beefs: 0-5 kGy; porks: 0-30 kGy) in areas such as genotoxicity, acute toxicity, four-week oral toxicity, rat ...

1988-04-18

313

Performance Evaluation of Several Types of Pulsed Eddy Current Probes for Detecting Wall Thickness Reduction  

Science.gov (United States)

In this paper, four different types of pulsed eddy current (PEC) probe are designed and their performance of detecting wall thickness reduction is compared. By using the backward difference method in time and the finite element method in space, PEC signals from various thickness and materials are numerically calculated and three features of the signal are selected. Since PEC signals and features are obtained by various types and sizes of probe, the comparison is made through the normalized features which reflect the sensitivity of the feature to thickness reduction. The normalized features indicate that the shielded reflection probe provides the best sensitivity to wall thickness reduction for all three signal features. Results show that the best sensitivity to thickness reduction is achieved by the peak value, but also suggest that the time to peak can be a good candidate because of its linear relationship with the ...

2010-02-01

314

Partial unmixing as a tool for single surface class detection and time series analysis  

British Library Electronic Table of Contents (United Kingdom)

In this paper we present the results of time series analysis for a coal mining region based on partial unmixing. We test the method also known as mixture tuned matched filtering on an eight image Landsat 5 TM and Landsat 7 ETM+ time series covering the period from 1987 to 2003. Common change detection methods often include the comparison of two interactively generated classification results, such as derived from Maximum Likelihood classification. These approaches often yield highly accurate results. However, disadvantages include a strong analyst bias and hardly repeatable results. For a quantitative monitoring of a single surface class' development over time they are often not recommendable. Our goal was to test an unbiased quantitative way to assess the development of coal surfaces, such...

2008-01-01

315

No evidence of over-reporting of SARS in mainland China  

British Library Electronic Table of Contents (United Kingdom)

Summary Objective To find out whether there was over-reporting of SARS patients in mainland China in view of the relatively low case fatality ratio in mainland China, in comparison with other affected countries and areas. Methods We searched PubMed for all SARS antibody detection papers (in English or Chinese language) using the keywords `SARS' and `antibody'. Then the resulting articles were further read through to select the SARS detection results using ELISA methods of serum samples collected at least 1 month after disease onset. A multi-level logistic regression was applied to test for possible differences in the proportions positive between locations of the study. Results A total of 48 studies were identified, including 39 from mainland China and nine from elsewhere (Hong Kong, Taiwan...

2009-01-01

316

Gear fault detection using customized multiwavelet lifting schemes  

British Library Electronic Table of Contents (United Kingdom)

Fault symptoms of running gearboxes must be detected as early as possible to avoid serious accidents. Diverse advanced methods are developed for this challenging task. However, for multiwavelet transforms, the fixed basis functions independent of the input dynamic response signals will possibly reduce the accuracy of fault diagnosis. Meanwhile, for multiwavelet denoising technique, the universal threshold denoising tends to overkill important but weak features in gear fault diagnosis. To overcome the shortcoming, a novel method incorporating customized (i.e., signal-based) multiwavelet lifting schemes with sliding window denoising is proposed in this paper. On the basis of Hermite spline interpolation, various vector prediction and update operators with the desirable properties of biorthog...

2010-01-01

317

Determination and removal of malondialdehyde and other 2-thiobarbituric acid reactive substances in waste cooking oil  

British Library Electronic Table of Contents (United Kingdom)

Waste cooking oil can be recovered and processed into animal feed additives after purification. Unfortunately, the traditional purification processes are insufficient for the removal of the harmful compounds formed during frying, mainly about malondialdehyde and other 2-thiobarbituric acid reactive substances. In the present paper, firstly, a simple and reliable HPLC method was developed to measure the content of malondialdehyde in purified waste cooking oil. The detection limit and the standard recovery of the analysis method are 1.20x10-5gl-1 and 96.5-99.2%, respectively, which is accurate and valid enough for the detection of malondialdehyde in waste cooking oil. Furthermore, the removal of malondialdehyde and other 2-thiobarbituric acid reactive substances from waste cooking oil was in...

2011-01-01

318

Biomagnetic separation of Salmonella Typhimurium with high affine and specific ligand peptides isolated by phage display technique  

Energy Technology Data Exchange (ETDEWEB)

Analyses of food-borne pathogens are of great importance in order to minimize the health risk for customers. Thus, very sensitive and rapid detection methods are required. Current conventional culture techniques are very time consuming. Modern immunoassays and biochemical analysis also require pre-enrichment steps resulting in a turnaround time of at least 24 h. Biomagnetic separation (BMS) is a promising more rapid method. In this study we describe the isolation of high affine and specific peptides from a phage-peptide library, which combined with BMS allows the detection of Salmonella spp. with a similar sensitivity as that of immunomagnetic separation using antibodies.

2007-04-15

319

CT colonography with minimal bowel preparation: evaluation of tagging quality, patient acceptance and diagnostic accuracy in two iodine-based preparation schemes  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to compare a 1-day with a 2-day iodine bowel preparation for CT colonography in a positive faecal occult blood test (FOBT) screening population. One hundred consecutive patients underwent CT colonography and colonoscopy with segmental unblinding. The first 50 patients (group 1) ingested 7*50 ml iodinated contrast starting 2 days before CT colonography. The latter 50 patients (group 2) ingested 4*50 ml iodinated contrast starting 1 day before CT colonography. Per colonic segment measurements of residual stool attenuation and homogeneity were performed, and a subjective evaluation of tagging quality (grade 1-5) was done. Independently, two reviewers performed polyp and carcinoma detection. The tagging density was 638 and 618 HU (p = 0.458) and homogeneity 91 and 86 HU for groups 1 and 2, respectively (p = 0.145). The tagging quality was graded 5 (excellent) in 90% of all segments in group 1 and 91% ...

2010-02-15

320

Rational protection of the quality of coastal waters by means of integrated, real-time management of the water environment; Proteccion racional de la calidad de las aguas costeras mediante la gestion integrada y en tiempo real del medio hidrico  

Energy Technology Data Exchange (ETDEWEB)

Before the implementation Water Framework directive, it was usual to forget that a good environment protection of the receiving waters needs a correct and coordinated operation of the subsystems of the water cycle, specially sewerage system, WWTP and receiving waters. This explains that most of the countries have focused their efforts in the treatment of dry weather flows forgetting the management of wet weather flows. Actually the idea that a sewerage system or a WWTP can not be planned or managed independently without considering the effects on the receiving waters is commonly accepted because not only each one of these systems must work correctly but also it is required a minimum impact in the receiving waters of the sewerage and WWTP overflows in dry and wet weather. All these links will affect the management strategy of the sewerage system (storm water detection tanks, gates, pumping stations, etc)., the interceptor, the WWTP and the receiving waters. Only an ...

2005-07-01

321

Focused ion beam etching of nanometer-size GaN/AlGaN device structures and their optical characterization by micro-photoluminescence/Raman mapping  

Energy Technology Data Exchange (ETDEWEB)

The authors report on the nano-fabrication of GaN/AlGaN device structures using focused ion beam (FIB) etching, illustrated on a GaN/AlGaN heterostructure field effect transistor (HFET). Pillars as small as 20nm to 300nm in diameter were fabricated from the GaN/AlGaN HFET. Micro-photoluminescence and UV micro-Raman maps were recorded from the FIB-etched pattern to assess its material quality. Photoluminescence was detected from 300nm-size GaN/AlGaN HFET pillars, i.e., from the AlGaN as well as the GaN layers in the device structure, despite the induced etch damage. Properties of the GaN and the AlGaN layers in the FIB-etched areas were mapped using UV Micro-Raman spectroscopy. Damage introduced by FIB-etching was assessed. The fabricated nanometer-size GaN/AlGaN structures were found to be of good quality. The results demonstrate the potential of FIB-etching for the nano-fabrication of III-V nitride devices.

2000-07-01

322

Advanced nanoscale separations and mass spectrometry for sensitive high-throughput proteomics  

Energy Technology Data Exchange (ETDEWEB)

We review recent development in separations and mass spectrometric instrumentation for sensitive and high-throughput proteomic analyses. These efforts have been primarily focused on the development of high-efficiency (separation peak capacity of ~103) nanoscale liquid chromatography (nanoLC; e.g., flow rates extending down to ~20 nL/min at optimal separation linear velocities through narrow packed capillaries) in combination with advanced mass spectrometry (MS), including high sensitivity and high resolution Fourier transform ion cyclotron resonance (FTICR) MS. This technology enables MS analysis of low nanogram-level proteomic samples (i.e., nanoscale proteomics) with individual protein identification sensitivity at the low zeptomole-level. The resultant protein measurement dynamic range can reach 106 for nanogram-sized proteomic samples, while more abundant proteins can be detected from complex sub-picogram size proteome samples. The average proteome ...

2005-06-01

323

One-step RNA pathogen detection with reverse transcriptase activity of a mutated thermostable Thermus aquaticus DNA polymerase.  

Science.gov (United States)

We describe the cloning and characterization of a mutated thermostable DNA polymerase from Thermus aquaticus (Taq) that exhibits an increased reverse transcriptase activity and is therefore designated for one-step PCR pathogen detection using established real-time detection methods. We demonstrate that this Taq polymerase mutant (Taq M1) has similar PCR sensitivity and nuclease activity as the respective Taq wild-type DNA polymerase. In addition, and in marked contrast to the wild-type, Taq M1 exhibits a significantly increased reverse transcriptase activity especially at high temperatures (>60 degrees C). RNA generally hosts highly stable secondary structure motifs, such as hairpins and G-quadruplexes, which complicate, or in the worst case obviate, reverse transcription (RT). Thus, RT at high temperatures is desired to weaken or melt secondary structure motifs. To demonstrate the ability of Taq M1 for RNA ...

2010-02-01

324

Development of methodics for the characterization of the composition of the ion-collision-induced secondary-particle flux by comparison of the yield contributions of photoinduced ion formation processes; Entwicklung einer Methodik zur Charakterisierung der Zusammensetzung des ionenbeschussinduzierten Sekundaerteilchenflusses durch Vergleich der Ausbeuteanteile photoinduzierter Ionenbildungsprozesse  

Energy Technology Data Exchange (ETDEWEB)

The aim of this work was to develop a method to distinguish between different ion formation processes and to determine the influence of these processes on the total number of detected monatomic ions of a certain element. A vector/matrix-formalism was developed, which describes the physical processes of sputtering, ion formation, mass separation and detection in laser-SNMS. In the framework of the method developed, based on this theoretic formalism, changes in the secondary flux contribution of the respective element were observed by comparing the detected monatomic ion yield obtained in specifically aligned (SIMS and) laser-SNMS experiments. The yields resulting from these experiments were used to calculate characteristic numbers to compare the flux composition from different surfaces. The potential of the method was demonstrated for the elements boron, iron and ...

2008-10-13

325

Phthalate monoesters in perfusate from a dual placenta perfusion system, the placenta tissue and umbilical cord blood  

British Library Electronic Table of Contents (United Kingdom)

Fetal exposure to phthalates may be associated with adverse reproductive effects, including cryptorchidism and decreased semen quality. Information about human placental transfer is needed to qualify the hypotheses. A dual recirculating placenta perfusion system to monitor concentrations of eight phthalate monoesters in fetal and maternal perfusates was established. In addition to perfusate background measures of phthalate monoesters, the concentrations in umbilical cord plasma and placenta tissue were measured. Monomethyl phthalate (mMP), monoethyl phthalate (mEP), monobutyl phthalate (mBP), and mono (2-ethyl-hexyl) phthalate (mEHP) were detected in both maternal and fetal perfusate, demonstrating a release of compounds from tissue or blood to perfusates. The distribution of compounds bet...

2007-01-01

326

Neutron-induced fission cross-section of {sup 233}U in the energy range 0.5<E{sub n}< 20 MeV  

Energy Technology Data Exchange (ETDEWEB)

The neutron-induced fission cross-section of {sup 233}U has been measured at the CERN n-TOF facility relative to the standard fission cross-section of {sup 235}U between 0.5 and 20MeV. The experiment was performed with a fast ionization chamber for the detection of the fission fragments and to discriminate against {alpha} -particles from the natural radioactivity of the samples. The high instantaneous flux and the low background of the n-TOF facility result in data with uncertainties of {approx} 3%, which were found in good agreement with previous experiments. The high quality of the present results allows to improve the evaluation of the {sup 233}U (n,f) cross-section and, consequently, the design of energy systems based on the Th/U cycle. (orig.)

2011-01-15

327

Air conditioning in high rise buildings; conditionnement d'air dans les immeubles de grande hauteur  

Energy Technology Data Exchange (ETDEWEB)

This book brings together the 103 presentations given at the 2. conference of the international institute of refrigeration (IIF/IIR) about air conditioning in high rise office buildings. The main themes are: design of air conditioning equipment for high buildings; air quality and thermal comfort inside these buildings; constraints and possible improvements of the refrigeration equipment used; energy conservation; fire protection and smokes detection. All themes are presented both on the technical and economical points of view and concern more particularly the buildings of Chinese cities. This publication is available both on the book and CD-Rom forms. (J.S.)

2000-07-01

328

A study of reconstruction algorithms and filters for an industrial X-ray tomography system  

Energy Technology Data Exchange (ETDEWEB)

Computed tomography (CT) has been incorporated in an industrial Diode-Array Digital Radiography (DADR) system. An input data size of 512 pixel points x 400 projections yielded a 400x400 output image matrix. Reconstruction algorithms used are the filtered backprojection (FBP) and the direct Fourier reconstruction (DFR). Various filters were used in the FBP reconstruction process and their effects on image quality were evaluated. A spatial resolution of 100 {mu}m was measured with a block of plates and a minimum detectable feature size in the range of 10-100 {mu}m was measured using thin wires. Industrial specimens imaged have included ceramic samples, ball bearings and integrated circuits. A number of engineering problems have been solved, such as adjustment of the X-ray source, centering of the rotator spindle in the view field and beam-hardening corrections. (orig.).

1990-12-20

329

High resolution Computed Tomography in the study of temporal bone trauma  

International Nuclear Information System (INIS)

Thirty-five patients with temporal bone fractures were examined; the fractures were sometimes associated with dislocation of the assicular chain caused by road fatalities. Computed Tomography (CT) was performed either because of the presence of clinical symptoms associated with trauma of the temporal bone, because of a hemotympanum discovered during a CT scan of the brain. Thirty-three fractures were detected: 19 longitudinal, 6 transverse, and 8 complex. An incudostapedial dislocation was also detected, together with a displacement of a stapedial prosthesis from the lenticular process of incus, and 3 incus-malleus dislocation associated with fractures. High resolution CT allows the precise definition of the course of the fractures, of the associated dislocation of the ossicular chain, and of facial nerve lesion, thus allowing a more accurate surgical intervention. In the examination of the temporal bone, high resolution CT is preferible to ...

1988-01-01

330

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two detectors, respectively and the imaging quality of phantoms. ...

2007-01-01

331

Submucosal Dexamethasone Injection Improves Quality of Life Measures After Third Molar Surgery: A Comparative Study  

British Library Electronic Table of Contents (United Kingdom)

PurposeThe purpose of the present study was to compare the effect of submucosal versus intramuscular administration of dexamethasone sodium phosphate on patients' quality of life after surgical removal of impacted lower third molars. Patients and MethodsA randomized, non-blind, clinical trial was planned. The sample was composed of patients requiring extraction under local anesthesia of a single partial bony impacted mandibular third molar with Class II or III and position B or C, according to the Pell and Gregory classification. The patients were randomly distributed into 1 of 3 groups: submucosal dexamethasone, intramuscular dexamethasone, and a control group that received no steroid. A modified translated questionnaire was used to assess the patients' perception regarding different qual...

2011-01-01

332

Somatic radiation risk in different mammography techniques  

International Nuclear Information System (INIS)

By measuring organ doses with TLD at an Alderson-Rando-phantom it was tested to evaluate the somatic risk for mammographies. Similarly as the genetic risk can be expressed by the genetic significant dose, the somatic risk can be expressed by the somatic significant dose index. The measurement results of the mammography show a large deviation of almost one power of ten with dependence of the chosen technique. In conventional xeroradiography and recording technique with foilless film the somatic radiation risk is the highest. By using amplifying foils in combination with high-sensitive films it is relatively small. Unfortunately the magnitude of the somatic risk in the different mammography techniques is in the ratio reciprocal to the corresponding image quality. At the time being the most favourable technique is mammography with a soft rastering method, although the xeromammography with additional high aluminium-filtering is a further ...

1981-01-01

333

Quality of life after surgery for rectal cancer with special reference to pelvic floor dysfunction  

British Library Electronic Table of Contents (United Kingdom)

Abstract Aim- Conventional outcomes such as survival, tumour recurrence and complication rates after surgery for rectal cancer have been rigorously assessed, but the importance of maintaining quality of life (QOL) after surgery for rectal cancer has received less attention. The aim of the current study was to analyse QOL and the occurrence of pelvic dysfunction after the surgical treatment of rectal cancer. Method- Between May 2005 and May 2008, 150 patients with rectal cancer underwent abdominoperineal resection (APR) or anterior resection (AR). Seventy-four answered two preoperative questionnaires. At a follow up of 1-year, 65 were alive without sign of recurrence and answered the same questionnaires: (a) validated RAND 36-item health survey QOL questionnaire; and (b) self-administered d...

2011-01-01

334

Normalized noise power spectrum of full field digital mammography detector system  

International Nuclear Information System (INIS)

Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)

335

Normalized Noise Power Spectrum of Full Field Digital Mammography System  

International Nuclear Information System (INIS)

A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.

2010-01-05

336

Mental health in patients with systemic sclerosis: a controlled investigation  

British Library Electronic Table of Contents (United Kingdom)

Abstract Background Despite the undeniable impact of systemic sclerosis (SS) on quality of life, only a few studies so far have focused on its psychiatric or psychological aspects. We aimed at assessing psychiatric symptoms and self-image in inpatients with SS and comparing them with patients with either a very mild skin condition or a serious skin condition. Methods Three groups were recruited: (i) 38 consecutive female inpatients with SS; (ii) 38 age-matched female outpatients with melanocytic naevi; (iii) 35 age-matched female inpatients with melanoma. All participants completed the Zung Anxiety Scale, the Zung Depression Scale and a self-report questionnaire measuring self-perceived personal qualities. Patients with SS were also clinically interviewed by a psychologist. Results The cli...

2008-01-01

337

Laparoscopic sigmoid resection for diverticular disease has no advantages over open approach: midterm results of a randomized controlled trial  

British Library Electronic Table of Contents (United Kingdom)

Purpose Elective laparoscopic sigmoid resection (LSR) for symptomatic diverticular disease is supposed to have significant short-term advantages compared to open surgery (open sigmoid resection (OSR)). This opinion is rather based on inferences from trials on colonic resections for malignant diseases or minor laparoscopic surgery. This randomized controlled trial was conducted to compare quality of life as well as morbidity and clinical outcome after LSR vs. OSR following a midterm follow-up period. Methods Patients presenting with a symptomatic sigmoid diverticular disease stage II/III (Stock/Hansen) were randomly allocated to LSR or OSR in a prospective multicenter trial. Endpoints included the quality of life assessed with a standardized questionnaire, postoperative mortality, and compl...

2011-01-01

338

Cost-effectiveness of a barrier-strengthening moisturizing cream as maintenance therapy vs. no treatment after an initial steroid course in patients with atopic dermatitis in Sweden - with model applications for Denmark, Norway and Finland  

British Library Electronic Table of Contents (United Kingdom)

Abstract Background Atopic dermatitis (AD) affects health and quality of life and it has great impact on both health-care costs and costs to the society. Objectives The objective of this study was to develop a model to analyse the cost-effectiveness of a barrier-strengthening moisturizing cream as maintenance therapy compared with no treatment after initial treatment with betamethasone valerate in adult patients with AD in Sweden. A further aim was to apply a similar health-economic analysis for Denmark, Norway and Finland. Methods A Markov simulation model was developed including data from three sources: (i) efficacy data from a randomized controlled trial including patients with moderate AD treated with either a moisturizing cream or no treatment, (ii) resource utilization and quality of...

2010-01-01

339

Comparison of skeletal and bone marrow radionuclide scintimetry of femoral neck fracture  

Energy Technology Data Exchange (ETDEWEB)

Twenty-six patients with late complications following femoral neck fracture were examined with both skeletal and bone marrow radionuclide scintimetry. There was no correlation between the methods with respect to the quantitative assessment of femoral head vascularity based on different uptake ratios comparing the fractured and the intact side. Skeletal scintimetry always had good image quality and permitted reliable differentation between nonunion of the fracture and late segmental collapse, in contrast to bone marrow scintimetry which gave poor image quality. Skeletal scintimetry thus seems superior to bone marrow scintimetry for assessment and differential diagnosis of late complications following femoral neck fracture. It is emphasized that the physiological mechanisms for radionuclide uptake must be taken into account when comparing scintimetric studies using different tracers.

1984-01-01

340

Comparison of skeletal and bone marrow radionuclide scintimetry of femoral neck fracture  

International Nuclear Information System (INIS)

Twenty-six patients with late complications following femoral neck fracture were examined with both skeletal and bone marrow radionuclide scintimetry. There was no correlation between the methods with respect to the quantitative assessment of femoral head vascularity based on different uptake ratios comparing the fractured and the intact side. Skeletal scintimetry always had good image quality and permitted reliable differentation between nonunion of the fracture and late segmental collapse, in contrast to bone marrow scintimetry which gave poor image quality. Skeletal scintimetry thus seems superior to bone marrow scintimetry for assessment and differential diagnosis of late complications following femoral neck fracture. It is emphasized that the physiological mechanisms for radionuclide uptake must be taken into account when comparing scintimetric studies using different tracers. (author).

341

A survey of point of care testing in Irish hospitals: room for improvement  

British Library Electronic Table of Contents (United Kingdom)

Background ?Guidelines for safe and effective management and use of point of care testing? have been recently launched in Ireland. Aims To survey point of care testing (POCT) services in the Republic of Ireland. Methods A questionnaire covering accreditation status, existence of POCT committees, quality management systems, and staff resources was distributed by the Irish External Quality Assessment Scheme (IEQAS). Results Of those that returned completed questionnaires, 56% had assigned specific POCT responsibilities to designated staff. Most support was for blood gases and glucose analysis. Compared with other published studies, Irish laboratories gave similar support for blood gases, less for glucose and much less for urinalysis. Conclusions This survey demonstrated poor IT support for P...

2011-01-01

342

The detection of spiral arm modulation in the stellar disk of an optically flocculent and an optically grand design galaxy  

CERN Document Server

Two dimensional Fourier spectra of near-infrared images of galaxies provide a powerful diagnostic tool for the detection of spiral arm modulation in stellar disks. Spiral arm modulation may be understood in terms of interference patterns of outgoing and incoming density wave packets or modes. The brightness along a spiral arm will be increased where two wave crests meet and constructively interfere, but will be decreased where a wave crest and a wave trough destructively interfere. Spiral arm modulation has hitherto only been detected in grand design spirals (such as Messier 81). Spiral arm amplitude variations have the potential to become a powerful constraint for the study of galactic dynamics. We illustrate our method in two galaxies: NGC 4062 and NGC 5248. In both cases, we have detected trailing and leading m=2 waves with similar pitch angles. This suggests that the amplification mechanism is the ...

2000-01-01

343

Real World Evaluation of Dual-Zone ICD and CRT-D Programming Compared to Single-Zone Programming: The ALTITUDE REDUCES Study  

British Library Electronic Table of Contents (United Kingdom)

Tachycardia Detection, ICD, CRT-D Devices, Appropriate and Inappropriate Shock.-Introduction: We evaluated the frequency of appropriate and inappropriate shocks and survival in patients using dual-zone programming versus single-zone programming. Methods and Results: For the ALTITUDE REDUCES study, patients were followed for 1.6 1.1 years. The 12-month incidence of any shock was lower for dual-versus single-zone programmed detection at rates -170 bpm and between 170-200 bpm (P < 0.001). Appropriate shock rates at 1 year were also lower with dual-zone programming in these rate intervals (single zone 9.1%, 5.4%, P < 0.001, dual zone 6.7%, 4.7%, P < 0.02). There were no detectable differences between single- and dual-zone shock incidence at detection rates - 200 bpm (P = 0.14). Inappropriate s...

2011-01-01

344

Pressure based leak detection system implanted on the business Unit Exploration and Production of PETROBRAS in Rio Grande do Norte e Ceara; Sistema de deteccao de vazamentos em dutos baseado em pressao implantado na Unidade de Negocios de Exploracao e Producao da PETROBRAS no Rio de Grande do Norte e Ceara  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the experience faced by people who works in PETROBRAS Business Unit (UN-RNCE), located in Rio Grande do Norte Province, Brazil, during the implementation of a pipeline leak detection system. That application involved nine multiphase oil pipelines distributed along several production facilities. Because of the emergency after the leakage that polluted the Guanabara bay and due to the two phases and multi phases pipelines characteristics, the UN-RNCE decided to apply the Pressure Point Analysis (PPA) technology in order to detect leakages. It is a statistical method for leak detection e uses a very simple instrumentation which facilitates the installation and maintenance. However, in order to get the best performance of the system, it is necessary to know thoroughly the whole process and have a fast and reliable SCADA system for long distance communication. Finally it will be shown the ...

2003-07-01

345

Boron-Lined Neutron Detector Measurements  

Energy Technology Data Exchange (ETDEWEB)

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. Reported here are the results of tests of a newly designed ...

2009-11-02

346

Probabilistic leak before break evaluation of straight pipes of primary heat transport piping of Tarapur-3 and 4 NPP  

International Nuclear Information System (INIS)

Piping systems transporting high-pressure fluid will release a large amount of energy, leading to whipping of the broken pipe as well as impingement of the ejecting fluids on adjacent structures if they fracture unstably. Postulation of such an event in design of piping systems in nuclear power plants often requires various counter measures such as installation of pipe whip restraints or jet impingement shields to prevent such damage. One of the approaches to justify exclusion of unstable fracture from the design conditions is leak-before-break (LBB) analysis. In order to demonstrate LBB behavior, it is necessary to prove that in the presence of a part-through wall flaw in the pipe, this flaw will not grow through the wall under fatigue loading and is stable (level 2 LBB) and that the leak of fluid through the penetration is detected by leak detection systems before unstable fracture occurs (level 3 LBB). If this can be demonstrated in plant ...

2006-11-01

347

Control system fabrication of fuel elements and assepblies for the FFTF reactor  

International Nuclear Information System (INIS)

The procedure and operation-by-operation methods of the quality control of structural and fuel materials, mixed fuel pellets of UO_2-PuO_2, fuel element cans made of the AISI-316 steel and ready fuel elements are described as well as spacer wires (steel AISI-316), cases of fuel assemblies (FA) and completed FAs. The methods are used in manifacturing fuel elements and FAs for the FFTF reactor. The RDT standards that regulate the structure and functioning of the system of fuel element and FA production management are outlined. Destructive analytical methods characterized by sufficient accuracy but low productivity are noted to represent a considerable share of operations. Some specialized means of nondestructive testing are developed, such as the gauge to measure the total plutonium content in a fuel element, neutron radiography deVice and a laser gauge to measure the FA dimensions. The experience gained ...

348

Control system fabrication of fuel elements and assemblies for the FFTF reactor  

Energy Technology Data Exchange (ETDEWEB)

The procedure and operation-by-operation methods of the quality control of structural and fuel materials, mixed fuel pellets of UO/sub 2/-PuO/sub 2/, fuel element cans made of the AISI-316 steel and ready fuel elements are described as well as spacer wires (steel AISI-316), cases of fuel assemblies (FA) and completed FAs. The methods are used in manifacturing fuel elements and FAs for the FFTF reactor. The RDT standards that regulate the structure and functioning of the system of fuel element and FA production management are outlined. Destructive analytical methods characterized by sufficient accuracy but low productivity are noted to represent a considerable share of operations. Some specialized means of nondestructive testing are developed, such as the gauge to measure the total plutonium content in a fuel element, neutron radiography deVice and a laser gauge to measure the FA dimensions. The ...

1984-01-01

349

Status of the WAND (Waste Assay for Nonradioactive Disposal) project as of July 1997  

Energy Technology Data Exchange (ETDEWEB)

The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform the data analysis. WAND system minimum detectable activities (MDAs) for point sources ...

1998-03-01

350

Recent advances in analytical determination of cisplatin and its hydrolysis products  

International Nuclear Information System (INIS)

Cisplatin (cis-diaminedichloroplatinum [II] is a coordination compound, used in the treatment of several solid tumors. Cisplatin and its hydrolysis products exhibit a great pharmacological effect but are very toxic and probably carcinogenic. The present review summarizes the most important advances in the last years in the techniques employed for the detection and quantification of cisplatin and its hydrolysis products and in the different matrixes studied. The new emerging techniques and their modifications recently developed, fundamentally the combined use of detection and separation techniques for the analysis of platinum species and their impact on the speed, sensitivity and specificity of the analytical determination, with regard to the techniques used in the last century are discussed. High-Performance Liquid Chromatography and Capillary Electrophoresis, coupled with detection methods such as Mass ...

2009-01-01

351

Measurements and elimination of Cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry  

International Nuclear Information System (INIS)

In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component of a fiber-optic radiation detector and to ...

2007-08-21

352

Electrochemical detection of DNA hybridization based on silver-enhanced gold nanoparticle label  

Energy Technology Data Exchange (ETDEWEB)

An electrochemical detection method for analyzing sequence-specific DNA using gold nanoparticle DNA probes and subsequent signal amplification step by silver enhancement is described. The assay relies on the electrostatic adsorption of target oligonucleotides onto the sensing surface of the glassy carbon electrode (GCE) and its hybridization to the gold nanoparticle-labeled oligonucleotides DNA probe. After silver deposition onto gold nanoparticles, binding events between probe and target were monitored by the differential pulse voltammetry (DPV) signal of the large number of silver atoms anchored on the hybrids at the electrode surface. The signal intensity difference permits to distinguish between the match of two perfectly matched DNA strands and the near-perfect match where just one base pair was wrong. Coupled with this 'nanoparticle-promoted' reduction of silver signal amplification method, the ...

2002-10-03

353

Radioanalytical methods of rare earth element determination  

International Nuclear Information System (INIS)

Instrumental neutron activation analysis (INAA) and radionuclide X-ray fluorescence analysis (RXFA) were used for the determination of rare earth elements. For INAA, solution obtained by sample decomposition was dripped onto filter paper, enclosed and sealed into a polyethylene foil. The sample was activated in reactor WWR-S over a period of 4 to 6 hours with a neutron fluence of 10"1"3cm"-"2. Gamma radiation measurement was carried out with a planar and a coaxial HP-Ge detector in three decay periods. La, Ce, Nd, Sm, Eu, Gd, Tb, Ho, Tm, Yb and Lu were determined. The advantage of the method is its accuracy and high sensitivity, the disadvantage is the time-consuming analysis. The RXFA method was used as a rapid and operative method for the analysis of loose ore samples, aqueous and organic solutions of rare earth elements. For exciting X-ray radiation, "2"4"1Am was used and the radiation of K-lines was ...

1989-06-01

354

European multicentre evaluation of the Super Aution SA-4220 urinalysis analyser.  

Science.gov (United States)

A multicentre evaluation of the urine test strip analyser Super Aution-4220 was carried out in six laboratories. The analytical performance of the instrument with regard to imprecision, linearity, detection limit, drift, carry-over and method comparison was studied. Using the Aution stick 8 test strip the pH, glucose, protein, ketones, bilirubin, blood, urobilinogen and leukocyte esterase were analysed. Specific gravity measurements were performed by refractive index method. Within-run and between-run imprecision determined at three levels of analyte were good. No carry-over was observed. Obtained results were linear through all the described analytical range. No significant drift was detected. Method comparison with some quantitative methods was performed and showed a good correlation with most of the analytes. The study of interferences showed minor ...

1998-12-01

355

Security of mobile agents: a new concept of the integrity protection  

CERN Document Server

The recent developments in the mobile technology (mobile phones, middleware) created a need for new methods of protecting the code transmitted through the network. The proposed mechanisms not only secure the compiled program, but also the data, that can be gathered during its "journey". The oldest and the simplest methods are more concentrated on integrity of the code itself and on the detection of unauthorized manipulation. Other, more advanced proposals protect not only the code but also the execution state and the collected data. The paper is divided into two parts. The first one is mostly devoted to different methods of securing the code and protecting its integrity; starting from watermarking and fingerprinting, up to methods designed specially for mobile agent systems: encrypted function, cryptographic traces, time limited black-box security, chained-MAC protocol, ...

2005-01-01

356

Optical dating: insufficiently bleached sediments  

International Nuclear Information System (INIS)

Although infrared-stimulated luminescence (IRSL) signals in feldspars can be bleached rapidly by sunlight, there could still be a small amount of IRSL signal remaining in sediment grains if they have experienced only relatively short sunlight exposure before deposition. This remaining signal results in a ''remnant dose'' stored in the grain and is important for young samples but negligible for old samples. Several methods have been introduced to detect insufficient bleaching, and some of them can provide information on the extent of the bleaching. Others can only distinguish between samples bleached for a very long time and for a short time. Empirical methods are introduced to evaluate the possible values of equivalent dose accumulated since the grains were deposited. These methods involve the analysis of the equivalent doses and the natural IRSL signals obtained using single-disc dose determination ...

1993-07-01

357

Headspace gas chromatographic method for determination of methyl bromide in food ingredients  

Energy Technology Data Exchange (ETDEWEB)

A headspace gas chromatographic (GC) method, which can be automated, has been developed for determination of methyl bromide. This method has been applied to wheat, flour, cocoa, and peanuts. Samples to be analyzed are placed in headspace sample vials, water is added, and the vials are sealed with Teflon-lined septa. After an appropriate equilibration time at 32 degrees C, the samples are analyzed within 10 h. A sample of the headspace is withdrawn and analyzed on a gas chromatograph equipped with an electron capture detector (ECD). Methyl bromide levels were quantitated by comparison of peak area with a standard. The standard was generated by adding a known amount of methyl bromide to a portion of the matrix being analyzed and which was known to be methyl bromide free. The detection limit of the method was 0.4 ppb. The coefficient of variation (CV) was 6.5% for wheat, 8.3% for flour, 3.3% for cocoa, and ...

1985-11-01

358

Quality Management for Neutron Transmutation Doping of Silicon Ingot in HANARO  

Energy Technology Data Exchange (ETDEWEB)

By using this doping method, silicon semiconductors with extremely uniform dopant distributions can be produced, and this is the dominant advantage of NTD compared with a conventional chemical doping. Good uniformity of a dopant concentration is usually required for high power applications such as thyristor (SCR), IGBT, IGCT and GTO and for special sensors. Achieving an accurate neutron fluence corresponding to a target resistivity as well as a uniform irradiation is the prime target of a neutron irradiation for NTD. Generally, in order to reach an accurate neutron fluence, a real time neutron flux is monitored by a neutron detector such as a Self-powered Neutron Detector(SPND). And, after an irradiation, the total irradiation fluence is confirmed by measuring the absolute activity of a neutron activation sample that has been irradiated with a silicon ingot, and thus the SPND can be properly calibrated. Excellent irradiation uniformity and a high accuracy for a ...

2007-10-15

359

Outdoor air quality and health effects : a case study  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the results of a study carried out at three sites in Madurai, India in order to assess ambient air quality levels and their impact on public health in urban areas. Indicators of public health were sought through primary and secondary health data and blood lead concentrations of male and female inhabitants and shopkeepers. Lean concentrations in blood samples were examined according to distance from the road, age, smoking status, hours of stay per day in the city, and period of stay in years in Madurai. Ambient air quality level indicators included the level of gaseous and particulate pollution using Central Pollution Control Board standard estimation methods. Observed atmospheric conditions across the three sites are examined according to mean solar insolation, mean temperature, mean relative humidity and mean wind velocity. The study concluded that pollution abatement measures must be implemented to ...

2005-07-01

360

Digital image precessing for neutron television fluoroscopic system and its application to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the reconstructed image. The image ...

1984-09-01

361

Digital image precessing for neutron television fluoroscopic system and its application to neutron computed tomography  

International Nuclear Information System (INIS)

The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the reconstructed image. The image ...

1984-01-01

362

Advanced fuzzy logic controllers design and evaluation for buildings' occupants thermal-visual comfort and indoor air quality satisfaction  

Energy Technology Data Exchange (ETDEWEB)

The aim of this paper is to present and evaluate control strategies for adjustment and preservation of air quality, thermal and visual comfort for buildings' occupants while, simultaneously, energy consumption reduction is achieved. Fuzzy PID, fuzzy PD and adaptive fuzzy PD control methods are applied. The inputs to any controller are: the PMV index affecting thermal comfort, the CO{sub 2} concentration affecting indoor air quality and the illuminance level affecting visual comfort. The adaptive fuzzy PD controller adapts the inputs and outputs scaling factors and is based on a second order reference model. More specifically, the scaling factors are modified according to a sigmoid type function, in such a way that the measured variable to be as closer as possible to the reference model. The adaptive fuzzy PD controller is compared to a non-adaptive fuzzy PD and to an ON-OFF one. The comparison criteria are the ...

2001-07-01

363

X-ray fluorescence analysis as auxiliary method of restorers  

International Nuclear Information System (INIS)

The principle is described of X-ray fluorescence analysis and the manner of detecting the emitted characteristic radiation. The advantages are presented of radionuclide X-ray fluorescence analysis which consist primarily in the possibility of conducting a totally non-destructive analysis, and of accurate and relatively narrow localization of the analyzed area, the simultaneous qualitative and quantitative determinations of a large number of elements in the order of concentrations 10"1 to 10"-"4%, stability of excitation radiation flux, simple design and relatively low capital costs. The so-called matrix effect is pointed to. A number of examples is given of the use of the cited method, including its use in the analysis of art objects. (J.B.).

1987-09-07

364

Observation of high-lying weak autoionizing resonances of Ne, and Mg atoms by charge-separated photoion-yield method  

Energy Technology Data Exchange (ETDEWEB)

Doubly-excited 2s{sup -1}2p{sup -1}3pnp autoionizing resonance series of Ne atom as well as autoionizing resonances in the 2s region of Na and Mg atoms have been studied with monochromatized synchrotron radiation. Use of charge-separated photoion-yield method allowed us to detect these weak resonances in a clarified way in the yield curves of doubly-charged ions. The observed resonance states have been interpreted with the help of MCDF calculations, and the decay processes of these resonance states are discussed briefly.

2007-03-01

365

Observation of high-lying weak autoionizing resonances of Ne, and Mg atoms by charge-separated photoion-yield method  

International Nuclear Information System (INIS)

Doubly-excited 2s-12p-13pnp autoionizing resonance series of Ne atom as well as autoionizing resonances in the 2s region of Na and Mg atoms have been studied with monochromatized synchrotron radiation. Use of charge-separated photoion-yield method allowed us to detect these weak resonances in a clarified way in the yield curves of doubly-charged ions. The observed resonance states have been interpreted with the help of MCDF calculations, and the decay processes of these resonance states are discussed briefly.

2007-03-01

366

Method of combustion for dual fuel engine  

Energy Technology Data Exchange (ETDEWEB)

Apparatus and a method of introducing a primary fuel, which may be a coal water slurry, and a high combustion auxiliary fuel, which may be a conventional diesel oil, into an internal combustion diesel engine comprises detecting the load conditions of the engine, determining the amount of time prior to the top dead center position of the piston to inject the main fuel into the combustion chamber, and determining the relationship of the timing of the injection of the auxiliary fuel into the combustion chamber to achieve a predetermined specific fuel consumption, a predetermined combustion efficiency, and a predetermined peak cylinder firing pressure. 19 figures.

1993-12-21

367

LET-dependence of the trapping parameters in TLD-100 determined with a computerised curve fitting method  

International Nuclear Information System (INIS)

With a computerized curve fitting method the trapping parameters of TLD-100 chips were calculated after #alpha#-, #beta#- and #gamma#-irradiation. The absorption of radiation produces an additional glow peak at 250 deg C, and the dominant one arises at 280 deg C. After the analysis of the glow curves only a little LET-dependence of the trap depths and that of the half widths was detected. The charge densities after irradiation before heating of the taps responsible for the high temperature glow peaks (T>240 deg C) show a LET-dependence. (author).

1985-10-22

368

Comprehensive characterization of fuel, clad and wrapper materials and assemblies for fast reactors - towards design, development and performance  

International Nuclear Information System (INIS)

The paper provides a brief description of the fuel characterization for Fast Breeder Test Reactor (FBTR) and Prototype Fast Breeder Reactor (PFBR). The development and characterization of mechanical properties of Alloy D9 clad and wrapper tubes are discussed. The problems associated with fusion welding of Alloy D9 are outlined. Non-destructive characterization of cladding tubes by optimum encircling eddy current probes, on-line and off-line neural network methods is presented. Both the on-line and off-line neural network methods could readily detect and size defects specified by the designers

2004-01-01

369

Characterization of nuclear fuels by ICP mass-spectrometric techniques  

British Library Electronic Table of Contents (United Kingdom)

Isotopic analyses of radioactive materials such as irradiated nuclear fuel are of major importance for the optimization of the nuclear fuel cycle and for safeguard aspects. Among the mass-spectrometric techniques available, inductively coupled plasma mass spectrometry (ICP-MS) and thermal ionization mass spectrometry are the most frequently applied methods for nuclear applications. Because of the low detection limits, the ability to analyze the isotopic composition of the elements and the applicability of the techniques for measuring stable as well as radioactive nuclides with similar sensitivity, both mass-spectrometric techniques are an excellent amendment to classical radioactivity counting methods. The paper describes selected applications of multicollector ICP-MS in combination with c...

2008-01-01

370

Uptake of oleate from albumin solutions by rat liver. Failure to detect catalysis of the dissociation of oleate from albumin by an albumin receptor.  

UK PubMed Central (United Kingdom)

The hepatic removal of albumin-bound substances from plasma requires that they dissociate from albumin. Using indirect methods, we and others have proposed that dissociation may be catalyzed by interaction...Full Text Available

1987-04-01

371

Uncommon bone tumors of the skull: Ewing's sarcoma and Triton's tumor  

International Nuclear Information System (INIS)

Ewing's sarcoma and Triton's tumor are two uncommon bone tumors of the skull that have nonspecific clinical and imaging features. However, imaging methods are important in the detection of the lesions during the diagnostic investigation in order to evaluate the extent of the bone lesions, involvement of the soft tissues and brain, and to determine the presence of local recurrence and metastases. The confirmatory diagnosis relies on histological studies and immunohistochemistry. The authors report two cases of patients with these tumors and present the radiological findings. (author)

372

Thorium different-ligand complexes with morin as analytic form for extraction-photometric determination of thorium microamounts  

International Nuclear Information System (INIS)

Consideration is given to results of investigation into thorium complexing with morin (H_2Mor) in extraction systems containing different carboxylic acids as well as different salt background. The obtained data enabled to suggest the method of photometric determination of thorium in the form of Th(HMor)_2Benz_2 different-ligand complex (where Benz-anion of benzilic acid) with 0.25 #mu#g/ml detection limit.

1989-01-01

373

Study of complexing reactions and ligand exchange of zirconium and hafnium tetrachlorides with substituted derivative of O-naphthoquinonediazide  

Energy Technology Data Exchange (ETDEWEB)

Using the PMR method the interaction of zirconium and hafnium tetrachlorides with tri.tet.butylphenyl ester of 1,2- naphthoquinonediazide (2)-5-sulfonic acid is studied. The formation of MCl/sub 4/xNQD complexes is established, the equilibrium constants and thermodynamic parameters of complexing reaction are determined. The presence of rapid ligand exchange, proceeding according to associative mechanism, is detected. The rate constants and activation energies of the exchange reaction are calculated.

1981-11-01

374

Study of complexing reactions and ligand exchange of zirconium and hafnium tetrachlorides with substituted derivative of O-naphthoquinonediazide  

International Nuclear Information System (INIS)

Using the PMR method the interaction of zirconium and hafnium tetrachlorides with tri.tet.butylphenyl ester of 1,2- naphthoquinonediazide (2)-5-sulfonic acid is studied. The formation of MCl_4xNQD complexes is established, the equilibrium constants and thermodynamic parameters of complexing reaction are determined. The presence of rapid ligand exchange, proceeding according to associative mechanism, is detected. The rate constants and activation energies of the exchange reaction are calculated.

375

Spectrophotometric technique quantitatively determines NaMBT inhibitor in ethylene glycol-water solutions  

Science.gov (United States)

Spectrophotometric method, using a ratio-recording ultraviolet-absorption spectrophotometer, permits analysis of NaMBT in ethylene glycol-water solutions with high accuracy. It reduces analysis time, requires smaller samples, and is able to detect extremely small concentrations of mercaptobenzothiazole.

1967-01-01

376

Spectrophotometric determination of rhenium with acetylacetone  

Energy Technology Data Exchange (ETDEWEB)

The optimum conditions of complex formation of rhenium(IV) with acetylacetone in water-ethanol medium were found, and a spectrophotometric method for determining rhenium with limit of detection 0.1 ..mu..g/ml was proposed. Rhenium can be determined in the presence of a 1000-fold excess of molybdenum. The procedure was tested on model solutions and used for the determination of rhenium in alloys.

1987-10-10

377

Scattered radiation effect on the defect image in high-energy bremsstrahlung introscopy  

International Nuclear Information System (INIS)

Results of the evaluation of the scattered radiation effect on the image of defects in examined products are given. The formula is suggested which characterizes the image of defects on a scintillation screen as well as accumulation factors are calculated by the Monte-Carlo method. Values of fluctuations of absorbed energy in the screen used for the evaluation of sensitivity are experimentally obtained. The effect of high-energy bremsstrahlung on the defect detection is analyzed.

378

Potential U.S. contributions to in-reactor experiments for fast reactor surveillance systems  

International Nuclear Information System (INIS)

It is maintained that special features of FFTF make it an ideal system to test sodium boiling detection techniques by acoustic/neutronic methods and to test the response of acoustic/neutronic sensors to vibrations. It is shown that accumulated research results indicate that such tests in FFTF are feasible, predictable, promising and safe. (author).

379

Pollution control instrumentation for oil and effluents  

Energy Technology Data Exchange (ETDEWEB)

This book provides discusses recent developments in oil pollution control instrumentation. Some of the topics covered are as follows: 1. Technical requirements of the IMCO International Performance and Test Specification A393x concerning oil content meters; and 2. Oil in water detection; and 3. Methods for the disposal of recovered oil and oily sludge; and 4. Oil content monitoring at ballast water treatment facilities and offshore production platforms.

1986-01-01

380

Nondestructive determination of airborne lead particulates by the radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).

1980-01-01

381

Nitrogen isotope identification by Bragg-curve spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

Projectilelike fragments following the 80 MeV /sup 16/O+/sup 27/Al reaction have been detected using a Bragg-curve spectroscopy ionization chamber (BCS-IC). The atomic number is deduced from the Bragg-peak amplitude. Nitrogen isotopes are clearly resolved using either range or energy loss data. This is the first application of the BCS method for complete ion identification in a heavy-ion-induced reaction.

1984-07-14

382

Nitrogen isotope identification by Bragg-curve spectroscopy  

International Nuclear Information System (INIS)

Projectilelike fragments following the 80 MeV "1"6O+"2"7Al reaction have been detected using a Bragg-curve spectroscopy ionization chamber (BCS-IC). The atomic number is deduced from the Bragg-peak amplitude. Nitrogen isotopes are clearly resolved using either range or energy loss data. This is the first application of the BCS method for complete ion identification in a heavy-ion-induced reaction.

383

Monitoring for Xenon Radionuclides and CTBT Verification  

International Nuclear Information System (INIS)

The Comprehensive Nuclear-Test-Ban-Treaty (CTBT), which was opened for signature in 1996, bans all nuclear explosions in all environments. Republic of Korea has been working to monitor compliance with CTBT by deterring and detecting any nuclear explosions conducted anywhere on Earth. For the verification of CTBT, several techniques are implemented. Radionuclide monitoring is of particular importance since it is the only method which can provide absolute assurance that a nuclear detonation has occurred

2010-10-01

384

Lyme myocarditis diagnosed by indium-111-antimyosin antibody scintigraphy  

Energy Technology Data Exchange (ETDEWEB)

We report a new case of Lyme disease with cardiac manifestations, which has been possible to follow during the long period of 12 years. We have detected the usual ECG abnormalities, and concentric hypertrophic myocardiopathy, by echocardiography. The acute myocarditis was demonstrated by /sup 111/In-antimyosin scintigraphy, which showed global myocardial uptake of the tracer, constituting the first report, to our knowledge, of Lyme myocarditis diagnosed by this method.

1989-06-01

385

Long-range correlation analysis of earthquake-related geochemical variations recorded in Central Italy  

Energy Technology Data Exchange (ETDEWEB)

The long-range correlation properties in the hourly time variability of geochemical signals measured in a 70 m depth well at Triponzo (Umbria region), are investigated by the detrended fluctuation analysis (DFA). DFA is a data processing method that allows for the detection of scaling behaviors in observational time series even in the presence of non-stationarities. The procedure adopted has allowed for the unambiguous identification of possible correlations among the recorded signals and local earthquakes.

2004-07-01

386

Identification and determination of elements in Taraxacum officinale plant from different Bratislava localities  

Energy Technology Data Exchange (ETDEWEB)

Elements Ti, Mn, Fe, Ni, Cu, Zn, Pb, Br, Rb and Sr were determined by the method of radionuclide X-ray fluorescence analysis with semiconductor detection in samples of Taraxacum officinale from various localities of Bratislava. The dependence of their content on the source and the degree of the air pollution was found out.

1983-01-01

387

Identification and determination of elements in Taraxacum officinale plant from different Bratislava localities  

International Nuclear Information System (INIS)

Elements Ti, Mn, Fe, Ni, Cu, Zn, Pb, Br, Rb and Sr were determined by the method of radionuclide X-ray fluorescence analysis with semiconductor detection in samples of Taraxacum officinale from various localities of Bratislava. The dependence of their content on the source and the degree of the air pollution was found out. (author).

1983-01-01

388

Heavy metals in welding fumes  

Energy Technology Data Exchange (ETDEWEB)

Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A /sup 241/Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer.

1984-10-01

389

Heavy metals in welding fumes  

International Nuclear Information System (INIS)

Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A "2"4"1Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer. (E.S.).

1984-01-01

390

Gene rearrangement and radiation carcinogenesis  

International Nuclear Information System (INIS)

The development of leukemia and thyroid cancer is characterized by activation of the abl oncogene and ret oncogene, respectively. In order to clarify the relationship between these gene aberrations and radiation, the pro-myelogenous leukemia-derived cell line HL60 and the thyroid cancer-derived cell line 8505C, were irradiated in vitro with 100Gy of X-rays. RNA was then extracted from 10"8 cells of the respective cell lines and examined by the reverse transcription PCR method for rearrangements of abl and ret genes. Five kinds of positive bands were observed in the HL-60 cells irradiated with 100Gy of X-ray. Similarly, six positive bands were also observed in the 8505C cells irradiated with 100Gy. In vitro X-irradiation activation of oncogenes found in radiation induced cancers imply that gene rearrangement by X-rays is involved in the development of malignant tumors. Furthermore, in an experiment to detect radiation effects in A-bomb ...

1993-11-01

391

Determination of [sup 99]Tc in sea water at ultra low levels  

Energy Technology Data Exchange (ETDEWEB)

A method based on the collection of [sup 99]Tc from 500 l sea water samples by anion exchange and further extraction of TcO[sub 4][sup -] into 5% triisooctylamine-xylene has been improved to include a decontamination factor 6.5x10[sup 5] for uranium. The detection limit for [sup 99]Tc is thereby reduced to 3 mBq/m[sup 3].

1994-01-20

392

Comparison of the NucliSens easyMAG and Qiagen BioRobot 9604 Nucleic Acid Extraction Systems for Detection of RNA and DNA Respiratory Viruses in Nasopharyngeal Aspirate Samples?  

UK PubMed Central (United Kingdom)

The NucliSens easyMAG and BioRot 9604 automated nucleic acid extraction systems were evaluated and compared with the manual QIAamp (Qiagen) extraction method for their abilities to extract nucleic acid...Full Text Available

2008-07-01

393

Clinical translation of ultraviolet autofluorescence microscopy towards endomicroscopy for early detection of cancer  

Science.gov (United States)

The non-invasiveness of autofluorescence technology may reduce sampling error and time delay for histopathology diagnosis. We establish biophotonic methods and guidelines to visualize and interpret early epithelial tissue changes that signify disease. Flexible and rigid fiber endomicroscopy instrumentation design parameters feasible for translation towards clinical use are in development.

2010-12-01

394

Analysis of TL glow curves in differently doped LiF:Mg,Ti  

International Nuclear Information System (INIS)

A computerised curve-fitting method was developed to calculate the trapping parameters in LiF TLD-100 and LiF:Mg, Ti. After irradiation in a "6"0Co field and with X rays emitted at different voltages the TL process is best described by first-order kinetics. A dependence of the trapping parameters on both the concentration of Mg and Ti and photon energy was detected. (author).

395

Unidirectional growth, linear and nonlinear optical, dielectric and mechanical properties of organic adduct of L-tartaric acid nicotinamide  

International Nuclear Information System (INIS)

An attempt has been made to grow L-tartaric acid nicotinamide (LTN); a complex of tartaric acid, by employing a modified unidirectional method. The crystalline structure and quality are investigated by single crystal XRD and rocking curve studies. The linear and nonlinear optical properties are studied by UV-vis-NIR spectral analysis, SHG test, phase matching and laser induced damage threshold measurement. For comparison, parallel growth of the crystal was carried out by conventional method and the properties of the LTN samples grown by the conventional and unidirectional methods are investigated. The mechanical, photoconductivity and dielectric behavior of LTN crystals are also investigated.

2011-03-15

396

Novel automated assay for the quality control of mexiletine hydrochloride formulations using sequential injection and on-line dilution  

British Library Electronic Table of Contents (United Kingdom)

The first automated method for the determination of mexiletine hydrochloride - an antiarrhythmic agent - is reported. The method is based on the reaction of the analyte with o-phthalaldehyde (OPA) in the presence of sulfite in basic medium using a sequential injection (SI) manifold. The reaction product was monitored spectrofluorimetrically (lex=350nm/lem=446nm). A simple and effective on-line dilution approach was adopted in order to expand the linearity and apply the method to assay, dosage uniformity and dissolution tests with minimum sample preparation. Chemical (pH, amount concentrations of OPA and sulfite) and instrumental variables (temperature, flow rate, injection volumes, etc.) that affected the determination were studied. The developed assay was validated in terms of linearity, ...

2008-01-01

397

Maximum entropy probability method applied to assess voltage sag frequency due to transmission line fault in the electric power system  

British Library Electronic Table of Contents (United Kingdom)

Abstract Voltage sag caused by faults on an electric power transmission line is one of the most intractable power quality issues for both utility companies and customers. The fault in power system randomly exists along transmission lines due to the combination of many uncertain factors. To predict and assess the annual expected sag frequency (ESF) deriving from the faults along lines, a stochastic based method that employs maximum entropy principle, namely the maximum entropy probability method (MEPM), has been introduced in this paper. Moreover, various types of faults have been considered systematically. With the fault line intervals and the sample moments taken into account, the discrete values of distribution probability of fault locations along the transmission lines have been estimat...

2010-01-01

398

Isolation of functional mitochondria from rat kidney and skeletal muscle without manual homogenization  

British Library Electronic Table of Contents (United Kingdom)

Isolation of functional and intact mitochondria from solid tissue is crucial for studies that focus on the elucidation of normal mitochondrial physiology and/or mitochondrial dysfunction in conditions such as aging, diabetes, and cancer. There is growing recognition of the importance of mitochondria both as targets for drug development and as off-target mediators of drug side effects. Unfortunately, mitochondrial isolation from tissue is generally carried out using homogenizer-based methods that require extensive operator experience to obtain reproducible high-quality preparations. These methods limit dissemination, impede scale-up, and contribute to difficulties in reproducing experimental results over time and across laboratories. Here we describe semiautomated methods to disrupt tissue ...

2011-01-01

399

Ion nitriding of aluminium  

Energy Technology Data Exchange (ETDEWEB)

The present study is devoted to the investigation of the mechanism of aluminium nitriding by a technique that employs implantation of low-energy nitrogen ions and diffusional transport of atoms. The nitriding of aluminium is investigated, because this is a method for surface modification of aluminium and has a potential for application in a broad spectrum of fields such as automobile, marine, aviation, space technologies, etc. However, at present nitriding of aluminium does not find any large scale industrial application, due to problems in the formation of stoichiometric aluminium nitride layers with a sufficient thickness and good quality. For the purposes of this study, ion nitriding is chosen, as an ion beam method with the advantage of good and independent control over the process parameters, which thus can be related uniquely to the physical properties of the resulting layers. Moreover, ion nitriding has a close ...

2002-09-01

400

Computerized management of time, tasks, and priorities  

Energy Technology Data Exchange (ETDEWEB)

Even before Egyptian times, fiber and paper-based methods were used to manage time, tasks, and priorities. Papyrus and paper were effective in their time, but now is the time for the even more effective computer-based methods of time management. This study compares paper and computer methods of the management of time, tasks, and priorities. Discussed are recommended strengths of off-the-shelf software for time management. Integrated software is recommended. A case study of the use of idea processing software to manage publication tasks and priorities is examined. Illustrated--for classroom-style training--are uses of a computer to enhance the quality and increase the efficiency of the coordination of publications from conception and research to printing and issuance. 3 refs., 43 figs.

1988-01-01

401

Comparison of methods used for preparation of biological CRM`s  

Energy Technology Data Exchange (ETDEWEB)

The starting material for two certified and one candidate reference material was obtained from dried grass specially cultivated on a selected and well prepared soil. The Community Bureau of Reference (BCR) of the Commission of the European Communities produced two certified reference materials (CRM`s) from this dried grass: a rye grass material (CRM 281) certified in 1988 for the quality control of trace and toxic element analyses and a hay powder material (CRM 129) certified in 1989 for monitoring trace and minor elements. A fraction of the dried grass was used in 1993 for the preparation of a hay powder with a particle size of < 63 {mu}m using newly developed grinding techniques. This paper compares the production methods of these three materials and the obtained particle size distribution of the powders. The analytical evaluation of these production methods was carried out by solid sampling Zeeman atomic absorption ...

1995-05-01

402

A rapid response air quality analysis system for use in projects having stringent quality assurance requirements  

International Nuclear Information System (INIS)

This paper describes an approach to solve air quality problems which frequently occur during iterations of the baseline change process. From a schedule standpoint, it is desirable to perform this evaluation in as short a time as possible while budgetary pressures limit the size of the staff available to do the work. Without a method in place to deal with baseline change proposal requests the environment analysts may not be able to produce the analysis results in the time frame expected. Using a concept called the Rapid Response Air Quality Analysis System (RAAS), the problems of timing and cost become tractable. The system could be adapted to assess other atmospheric pathway impacts, e.g., acoustics or visibility. The air quality analysis system used to perform the EA analysis (EA) for the Salt Repository Project (part of the Civilian Radioactive Waste Management Program), and later to evaluate the ...

403

Advantages of magnification in digital phase-contrast mammography using a practical X-ray tube  

Energy Technology Data Exchange (ETDEWEB)

Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point source results in a phase contrast too narrow for detection with CR. In addition to phase contrast improving image quality, a re-scaling effect ...

2008-12-15

404

Station set residual : event classification using historical distribution of observing stations.  

Science.gov (United States)

Analysts working at the International Data Centre in support of treaty monitoring through the Comprehensive Nuclear-Test-Ban Treaty Organization spend a significant amount of time reviewing hypothesized seismic events produced by an automatic processing system. When reviewing these events to determine their legitimacy, analysts take a variety of approaches that rely heavily on training and past experience. One method used by analysts to gauge the validity of an event involves examining the set of stations involved in the detection of an event. In particular, leveraging past experience, an analyst can say that an event located in a certain part of the world is expected to be detected by Stations A, B, and C. Implicit in this statement is that such an event would usually not be detected by Stations X, Y, or Z. For some well understood parts of the world, the absence of one or more ...

2010-04-01

405

Evaluation of calcification in pulmonary nodules using bone images obtained with single exposure energy subtraction  

Energy Technology Data Exchange (ETDEWEB)

Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: (1) conventional radiography (CXR), (2) low kV conventional radiography (Low), (3) Fuji computed radiography (FCR), (4) bone images with conventional singles exposure energy subtraction (ES) and (5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, images of 42 lung nodules (21 calcified lung nodules and 21 ...

1995-08-01

406

Evaluation of calcification in pulmonary nodules using bone images obtained with single exposure energy subtraction  

International Nuclear Information System (INIS)

Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: 1) conventional radiography (CXR), 2) low kV conventional radiography (Low), 3) Fuji computed radiography (FCR), 4) bone images with conventional singles exposure energy subtraction (ES) and 5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, images of 42 lung nodules (21 calcified lung nodules and 21 ...

1995-01-01

407

Characterization of a time-of-flight mass spectrometer and its applications in the study of solid surfaces; Charakterisierung eines Flugzeitmassenspektrometers und seine Anwendungen in der Festkoerperoberflaechenuntersuchung  

Energy Technology Data Exchange (ETDEWEB)

The object and the purpose of the present work was to develop, to assemble and to start running a new TOF (time of flight) mass spectrometer for imaging SNMS analytic which is optimized for the analysis of highly molecular secondary ions. The most important purpose was the characterization of the TOF mass spectrometer. The obtained mass spectra of indium, tantalum and silver clusters reflect the excellent properties of the TOF mass spectrometer for the detection of large clusters with good detection efficiency up to masses of 16000 amu. The possibility of the deflection of selected saturated atom and cluster peaks serves for further improvement of the detection efficiency for large molecules. The accessible mass resolution was determined to be of the order of m/{delta}m=1000 in the high mass region. Numerous measurements were carried out to characterize the useful yield of this spectrometer. For a best possible adaptation ...

2006-12-21

408

Scientific information and public opinion. Daily press analysis about ozone hole in the years 1996-1997; Informazione scientifica e opinione pubblica. Analisi della stampa quotidiana italiana negli anni 1996-1997 sul tema del buco dell'ozono  

Energy Technology Data Exchange (ETDEWEB)

One of ENEA's many activities consists in dealing with the analysis of information strategies. In this case the analysis concerns an environmental issue, the ozone hole which, in spite of the consideration given by the media, is not sufficiently highlighted, as well as in the case of climate changes issue. A survey of the coverage of four daily newspapers was realized; the time period covered by the analysis spans form January 1996 to December 1997, 77 articles in total. The newspapers involved are: La Repubblica, Il Corriere della Sera, L'Unita' on a national scale, and Il Resto del Carlino on a regional scale. The number of articles analyzed is divided as follows: 26 for the Repubblica, 24 for the Corriere della Sera, 21 for the Unita', 6 for the Resto del Carlino. The purpose of the work was to detect quality and quantity indicators of the Italian press about the ozone hole issue and possible environmental ...

1999-07-01

409

The use of molecular biology techniques for the diagnosis and epidemiological study of foot-and-mouth disease virus in Thailand  

International Nuclear Information System (INIS)

The detection of foot-and-mouth disease (FMD) virus from various kinds of field samples (tissue extract and cell culture isolate) was studied using the polymerase chain reaction (PCR) technique. The gene selected for diagnosis was the polymerase gene and an amplification target product of 454 bp in length was produced using AP5/AP6 primer sets. The PCR product was further examined by NcoI endonuclease digestion. The presence of the internal restriction site was confirmed by demonstration of two small fragments of 330 bp and 124 bp in length. Forty-nine samples that gave positive and negative results by ELISA typing and were positive by the PCR test were tested by NcoI digestion to confirm the results. About 10% of PCR products could not be confirmed by the method. Furthermore the FMD RNA polymerase gene could be detected by the PCR method in samples negative in both ELISA typing and the virus isolation ...

2000-05-01

410

Current Status on Stress Diagnostic Kit and Detection Technology  

Energy Technology Data Exchange (ETDEWEB)

The accurate measurement of a stress level is one of the most important issues in a stress diagnosis and its measurement could be of great value in clinical medicine. Stress has a potent effect on the spirit and physical condition of an individual. There are various methods available for its measurement. Some of the commonly used techniques for the diagnosis of a stress level include analysis of the body fluids, questionnaire assessments, psychophysiological evaluations and by determining heart rate variability (HRV) of subjects. However, the existing diagnostic methods have several defects like, a low sensitivity, inaccuracy and long of operation time. In this report, we present a diagnostic technology to detect a stress level which is the origin of various diseases. This method can be of great help in providing an early diagnosis through a biosensor and might play a vital role in preventing diseases ...

2008-06-15

411

The map equation  

CERN Document Server

Many real-world networks are so large that we must simplify their structure before we can extract useful information about the systems they represent. As the tools for doing these simplifications proliferate within the network literature, researchers would benefit from some guidelines about which of the so-called community detection algorithms are most appropriate for the structures they are studying and the questions they are asking. Here we show that different methods highlight different aspects of a network's structure and that the the sort of information that we seek to extract about the system must guide us in our decision. For example, many community detection algorithms, including the popular modularity maximization approach, infer module assignments from an underlying model of the network formation process. However, we are not always as interested in how a system's network structure was formed, as we are in how a ...

2009-01-01

412

The Galactic Exoplanet Survey Telescope (GEST)  

CERN Document Server

The Galactic Exoplanet Survey Telescope (GEST) will observe a 2 square degree field in the Galactic bulge to search for extra-solar planets using a gravitational lensing technique. This gravitational lensing technique is the only method employing currently available technology that can detect Earth-mass planets at high signal-to-noise, and can measure the frequency of terrestrial planets as a function of Galactic position. GEST's sensitivity extends down to the mass of Mars, and it can detect hundreds of terrestrial planets with semi-major axes ranging from 0.7 AU to infinity. GEST will be the first truly comprehensive survey of the Galaxy for planets like those in our own Solar System.

2002-01-01

413

Rocky Mountain spotted fever in areas of high and low prevalence: survey for canine antibodies to spotted fever rickettsiae.  

Science.gov (United States)

Antibodies to Rickettsia rickettsii were detected by indirect immunofluorescence in sera from 149 of 467 dogs (32%) examined from 4 military installations located in Kentucky, North Carolina, Pennsylvania, and Virginia. The prevalence at individual installations ranged from 4.3% at Fort Knox, Ky, to 63.4% at Fort Bragg, NC. Most of the seropositive dogs were in the working and sporting groups of dogs. The difference in antibody prevalence between sexes was not significant. Serologic responses were related to R rickettsii infection, although antibodies to R montana also were detected in a few of the sera. Comparison of serodiagnostic methods indicated that the indirect fluorescent antibody test was more sensitive than was the indirect hemagglutination test for obtaining survey data on the prevalence of Rocky Mountain spotted fever in the area. PMID:6808878

1982-08-01

414

Real-time neutron monitoring method using an imaging plate  

Energy Technology Data Exchange (ETDEWEB)

A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)

1999-07-01

415

Real-time neutron monitoring method using an imaging plate  

International Nuclear Information System (INIS)

A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)

1999-04-19

416

Properties of different eddy-current probes for steam generator tube testing  

Energy Technology Data Exchange (ETDEWEB)

With steam generator check testing, the numerous types of defect not only have to be detected reliably but also to be identified correctly and classified according to depth. A priori, no signals are provided by the physical eddy-current mechanism, i.e. the disturbance of an excited eddy-current field by a defect, which will allow unambiguous identification and classification of the defects. The task, therefore, consists in designing the eddy-current method in terms of measurement technology in such a way as to obtain useful detection, identification and classification by a translation of the signals as simple and as save as possible. Internal through-flow wils and internal rotating probes were examined for their suitability to fulfill this three-pronged task with steam generator inspection.

1981-01-01

417

Properties of different eddy-current probes for steam generator tube testing  

International Nuclear Information System (INIS)

With steam generator check testing, the numerous types of defect not only have to be detected reliably but also to be identified correctly and classified according to depth. A priori, no signals are provided by the physical eddy-current mechanism, i.e. the disturbance of an excited eddy-current field by a defect, which will allow unambiguous identification and classification of the defects. The task, therefore, consists in designing the eddy-current method in terms of measurement technology in such a way as to obtain useful detection, identification and classification by a translation of the signals as simple and as save as possible. Internal through-flow wils and internal rotating probes were examined for their suitability to fulfill this three-pronged task with steam generator inspection. (orig./RW).

1981-01-01

418

Progress Report Towards the ICANOE Detector  

CERN Document Server

We present a proposal for a combined ICARUS & NOE general purpose detector, to be installed in Hall B of the Gran Sasso Laboratory.The main scientific goal is the one of elucidating in a comprehensive way the pattern of neutrino $9 masses and mixings, following both (1) the S-KAM results and (2) the predictions on atmospheric neutrinos of the large solution of the Solar Neutrinos deficit. To achieve these goals, the experimental method is based upon the $9 complementary and simultaneous detection of CERN beam (CNGS) and cosmic ray (CR) events. This is made possible because of the complete isotropy of the detection technique. For the currently allowed values of the S-KAM results, both $9 CNGS and cosmic ray data will give independent measurements and provide a precise $(sin^{2}2\\theta; \\Delta m^{2})$ determination rather than a wide band of allowed values. Since we can observe and unambiguously identify $9 $\

1999-01-01

419

Nano photonic sensors for microdamage detection : an exploratory simulation.  

Energy Technology Data Exchange (ETDEWEB)

Nano photonic materials are synthetically manufactured crystals at the nano scale with the target of creating a microstructure with a special electro-magnetic periodicity. Such nano photonic materials have the ability to control light propagation and thus are capable of creating photonic bandgaps in the frequency domain. We propose using nano photonic crystals as sensors to detect microdamage in composite materials. We demonstrate using a simulation model that a nano photonic sensor attached to a composite bar experiences a significant change in its bandgap profile when damage is induced in the composite bar. The model predicts the frequency response of the nano photonic sensor using the transfer matrix method. A damage metric to evaluate the change in the frequency response is developed. Successful developments of nano photonic sensors allow damage identification at scales not attainable using current sensing technologies.

2005-04-01

420

Monoclonal antibodies: new agents for cancer detection and targeted therapy  

International Nuclear Information System (INIS)

Antibodies directed against markers on cancer cells are gaining in importance for the purpose of targeting diagnostic and therapeutic agents. In the past, this approach has had very limited success principally because the classical methods for producing antibodies from blood serum of animals immunized with cancer cells or extracts were unsatisfactory. The situation has changed dramatically since 1975 following the design of procedures for 'immortalizing' antibody-producing cells (lymphocytes) by fusing them with cultured myeloma cells to form hybridomas which continuously secrete antibodies. Since these hybridomas produce antibodies coded for by a single antibody-producing cell, the antibodies are called monoclonal. Building on these advances in biomedical research, it is now possible to reproducibly manufacture monoclonal antibodies on a scale suitable for use in cancer detection and therapy.

421

In vivo chicken model for peripheral intravascular human fibrin clot detection  

Energy Technology Data Exchange (ETDEWEB)

A chicken model was prepared that provides a simple and economical method of evaluating the use of fibrin-specific monoclonal antibody 64C5 in the detection of peripheral vascular thrombi. Human fibrin was clotted in segments of a chicken's femoral artery and vein prior to intravenous injection of radioiodinated antibody 64C5. After a 3-hr perfusion time, the thrombosed and contralateral control segments of the vessels were excised and counted for radioactivity. The radiolabeled 64C5 uptake ratio of the thrombosed segment to the control segment was 5.4 +/- 1.2 (p less than 0.007) in the femoral artery, and 3.8 +/- 1.1 (p less than 0.02) in the femoral vein. This in vivo chicken model may also find application in studies of targeting agents for human fibrin.

1988-08-01

422

Field results using measurement-while-drilling directional systems in Long Beach, California  

Energy Technology Data Exchange (ETDEWEB)

One of the more extensive uses of directional drilling anywhere in the world has been in the development of the East Wilmington Oil Field in Long Beach, California. The Measurement-While-Drilling (MWD) directional system has been tested on several wells and proven to provide the required accuracy, along with many advantages over past methods, used in the field development. Accurate transmission by MWD of bottom-hole measurements to the surface is provided by mud pressure pulses generated in the drill pipe downhole and detected by a pressure transducer includes the means for detecting, recording and processing these pressure pulses, to translate the information from the pressure pulses to rig floor displays usable by the drilling crew. 2 refs.

1981-01-01

423

Evaluation of surgical gamma probes for sentinel node localisation in cervical and vulvar cancer  

International Nuclear Information System (INIS)

Sentinel node (SN) scintigraphy for cervical and vulvar cancer guides the gynaecological oncologist in finding the metastatic lymph nodes during lymphadenectomy. The role of the surgical gamma probe in the sentinel node concept in gynaecological oncology is to localise (SN) both intra-operatively and transcutaneously. Intra-operative hand-held collimated gamma probes are increasingly used for detection of the sentinel lymph node. A comparative evaluation of handheld gamma probes: Neoprobe 1500, Europrobe, Gamma Finder, Gamma Ray Prospector GRP1 and GPR2 was performed using different detection methods. Laboratory tests were performed in which sensitivity, spatial resolution and angular sensitivity were evaluated. The results for each gamma probe were summarised and discussed. Awareness of a gamma probes capabilities and limitations should be considered in the appropriate selection of a device. (author)

424

Estimating personal costs incurred by a woman participating in mammography screening in the National Breast and Cervical Cancer Early Detection Program  

British Library Electronic Table of Contents (United Kingdom)

BACKGROUND.The National Breast and Cervical Cancer Early Detection Program (NBCCEDP) covers the direct clinical costs of breast and cervical cancer screening and diagnostic follow-up for medically underserved, low-income women. Personal costs are not covered. In this report, the authors estimated personal costs per woman participating in NBCCEDP mammography screening by race/ethnicity and also estimated lifetime personal costs (ages 50-74 years).METHODS.A decision analysis model was constructed and parameterized by using empiric data from a retrospective cohort survey of mammography rescreening among women ages 50 years to 64 years who participated in the NBCCEDP. Data from 1870 women were collected from 1999 to 2000. The model simulated the flow of resources incurred by a woman participat...

2008-01-01

425

Detection of previous neutron irradiation and reprocessing of uranium materials for nuclear forensic purposes  

International Nuclear Information System (INIS)

The paper describes novel analytical methods developed for the detection of previous neutron irradiation and reprocessing of illicit nuclear materials, which is an important characteristic of nuclear materials of unknown origin in nuclear forensics. Alpha spectrometry and inductively coupled plasma sector-field mass spectrometry (ICP-SFMS) using solution nebulization and direct, quasi-non-destructive laser ablation as sample introduction were applied for the measurement of trace-level "2"3"2U, "2"3"6U and plutonium isotopes deriving from previous neutron irradiation of uranium-containing nuclear materials. The measured radionuclides and isotope ratios give important information on the raw material used for fuel production and enable confirm the supposed provenance of illicit nuclear material.

2009-04-01

426

Detection of Visual Deficits in Aging DBA/2J Mice by Two Behavioral Assays  

British Library Electronic Table of Contents (United Kingdom)

Purpose: The DBA/2J mice have been used as an animal model for human pigmentary glaucoma. However, these mice develop various degrees of disease symptoms at different ages, making it difficult to detect pathological changes of retinal degeneration at glaucoma onset. The purpose of this study is to develop a non-invasive assay to identify individual mice that develop visual deficits. Materials and Methods: We apply two behavioral tests, a swimming test of visual discrimination and a test of optomotor response, to identify glaucomatous DBA/2J mice. We then examine whether the elevation of intraocular pressure (IOP), the common risk factor for glaucoma, affects visual performances of the DBA/2J mice. We further compare the retinal ganglion cell death, one of the signature glaucoma symptoms, i...

2011-01-01

427

Cryo-irradiation as a terminal method for the sterilization of drug aqueous solutions  

British Library Electronic Table of Contents (United Kingdom)

The aim of this study is to evaluate the specificities of the irradiation of drugs in frozen aqueous solution. The structures of the degradation products were determined to gain insight into the radiolysis mechanisms occurring in frozen aqueous solutions. Metoclopramide hydrochloride and metoprolol tartrate were chosen as models. The frozen solutions were irradiated at dry ice temperature by high energy electrons at various doses. The drug purity (chemical potency) and the radiolysis products were quantified by HPLC-DAD. Characterization of the degradation products was performed by LC-APCI-MS-MS. The structures of the radiolysis products detected in irradiated frozen aqueous solutions were compared to those detected in solid-state and aqueous solutions (previous studies). For both metoclop...

2008-01-01

428

Coupling of magnetostriction and electrostriction in the porous rheological composite  

Energy Technology Data Exchange (ETDEWEB)

The production method of the elastic composite containing ferrous particles and titanium barium particles dispersed in the porous silicone matrix is described in this article. Since it contains ferrous and titanium barium particles, this composite shows magnetorheological and also electrorheological properties. The electrostriction of composite samples in the electric field with maximal intensity 1.5x10{sup 6} V/m was investigated. The magnetostriction in the magnetic field with maximal induction 1 T was also investigated. It was found that samples elongate with increased electric field intensity, and the magnetic field induction was detected. By increasing the samples' elongation with increase of ferrous particles, titanium barium particles and pores number were also detected. In the investigated division of the electric and magnetic field the elongation changed in a linear way. The maximal elongation achieved was ...

2008-08-15

429

Cosmic ray antiproton/electron discrimination capability of the CAPRICE silicon-tungsten calorimeter using neural networks  

Energy Technology Data Exchange (ETDEWEB)

A data analysis based on an artificial neural network classifier is proposed to identify cosmic ray antiprotons detected with the CAPRICE silicon-tungsten imaging calorimeter against electron background in the energy range 1.2-4.0 GeV. A set of new physical variables, describing the events inside the calorimeter on the base of their different patterns, are introduced in order to discriminate between hadronic and electromagnetic showers. The ability of the artificial neural network classifier to perform a careful multidimensional analysis gives the possibility to identify antiprotons with an electron rejection 408{+-}85 (stat) at 95.0{+-}0.2 (stat)% of signal detection efficiency. The high accuracy achieved by this method improves substantially the efficiency in the evaluation of the cosmic ray antiproton spectrum. (orig.).

1996-11-01

430

Catalyst and method for reduction of nitrogen oxides  

Energy Technology Data Exchange (ETDEWEB)

A Selective Catalytic Reduction (SCR) catalyst was prepared by slurry coating ZSM-5 zeolite onto a cordierite monolith, then subliming an iron salt onto the zeolite, calcining the monolith, and then dipping the monolith either into an aqueous solution of manganese nitrate and cerium nitrate and then calcining, or by similar treatment with separate solutions of manganese nitrate and cerium nitrate. The supported catalyst containing iron, manganese, and cerium showed 80 percent conversion at 113 degrees Celsius of a feed gas containing nitrogen oxides having 4 parts NO to one part NO.sub.2, about one equivalent ammonia, and excess oxygen; conversion improved to 94 percent at 147 degrees Celsius. N.sub.2O was not detected (detection limit: 0.6 percent N.sub.2O).

2008-08-19

431

Catalyst and method for reduction of nitrogen oxides  

Energy Technology Data Exchange (ETDEWEB)

A Selective Catalytic Reduction (SCR) catalyst was prepared by slurry coating ZSM-5 zeolite onto a cordierite monolith, then subliming an iron salt onto the zeolite, calcining the monolith, and then dipping the monolith either into an aqueous solution of manganese nitrate and cerium nitrate and then calcining, or by similar treatment with separate solutions of manganese nitrate and cerium nitrate. The supported catalyst containing iron, manganese, and cerium showed 80 percent conversion at 113 degrees Celsius of a feed gas containing nitrogen oxides having 4 parts NO to one part NO.sub.2, about one equivalent ammonia, and excess oxygen; conversion improved to 94 percent at 147 degrees Celsius. N.sub.2O was not detected (detection limit: 0.6 percent N.sub.2O).

2008-05-27

432

Authentication of byte sequences  

Energy Technology Data Exchange (ETDEWEB)

Algorithms for the authentication of byte sequences are described. The algorithms are designed to authenticate data in the Storage, Retrieval, Analysis, and Display (SRAD) Test Data Archive of the Radiation Effects and Testing Directorate (9100) at Sandia National Laboratories, and may be used in similar situations where authentication of stored data is required. The algorithms use a well-known error detection method called the Cyclic Redundancy Check (CRC). When a byte sequence is authenticated and stored, CRC bytes are generated and attached to the end of the sequence. When the authenticated data is retrieved, the authentication check consists of processing the entire sequence, including the CRC bytes, and checking for a remainder of zero. The error detection properties of the CRC are extensive and result in a reliable authentication of SRAD data.

1991-06-01

433

Monitoring of the insecticide trichlorfon by phosphorus-31 nuclear magnetic resonance ({sup 31}P NMR) spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

Trichlorfon is an organophosphorus insecticide, which is extensively being used for protection of fruit crops. Trichlorfon is a thermal labile compound, which cannot be easily determined by gas chromatography (GC) and has no suitable group for sensitive detection by high performance liquid chromatography (HPLC). In this study, a {sup 31}P nuclear magnetic resonance ({sup 31}P NMR) has been described for monitoring of trichlorfon without any separation step. The quantitative works of {sup 31}P NMR spectroscopy has been performed in the presence of an internal standard (hexamethylphosphoramide). Limit of detection (LOD) for this method has been found to be 55 mg L{sup -1}, without any sample preparation, and the linear working range was 150-5500 mg L{sup -1}. Relative standard deviation (R.S.D.%) of the method for three replicates within and between days was obtained {<=}9%. The average recovery ...

2006-08-25

434

Luminescence characteristics for the detection of radiation treatment of shellfish by using isolated minerals  

International Nuclear Information System (INIS)

Seven types of shellfish were irradiated by gamma ray at doses of 0, 3 and 6 kGy. Pulse photo-stimulated luminescence (PPSL) and thermoluminescence (TL) methods were employed to detect the radiation treatment. The screening of irradiation was carried out by the PPSL method followed by identification using the TL technique. Most of the irradiated shellfish were screened out correctly and only a few showed photon counts a bit higher than the lower threshold value by much lower than the upper threshold value. The TL method was employed using minerals isolated from all the control and irradiated shellfish samples by density gradient treatment. Three parameters, integrated intensities of first glow curves (TL1), ratios of first to that of second glow curves (TL1/TL2), and the shapes of maxima of first glow curves, were utilized for the identification of gamma ray treatment of shellfish. (author)

435

Effective multiplication factor measurement by feynman-{alpha} method. 3  

Energy Technology Data Exchange (ETDEWEB)

The sub-criticality monitoring system has been developed for criticality safety control in nuclear fuel handling plants. In the past experiments performed with the Deuterium Critical Assembly (DCA), it was confirmed that the detection of sub-criticality was possible to k{sub eff} = 0.3. To investigate the applicability of the method to more generalized system, experiments were performed in the light-water-moderated system of the modified DCA core. From these experiments, it was confirmed that the prompt decay constant ({alpha}), which was a index of the sub-criticality, was detected between k{sub eff} = 0.623 and k{sub eff} = 0.870 and the difference of 0.05 - 0.1{Delta}k could be distinguished. The {alpha} values were numerically calculated with 2D transport code TWODANT and monte carlo code KENO V.a, and the results were compared with the measured values. The differences between calculated and measured values were proved ...

1998-06-01

436

Determination of low level sulfides in environmental waters by automated gas dialysis/methylene blue colorimetry  

Energy Technology Data Exchange (ETDEWEB)

A sensitive and rapid automated method has been developed for the selective analysis of acid extractable sulfide in environmental samples by combining gas dialysis separation techniques with methylene blue detection procedures. Acid extractable sulfide is separated from the sample matrix by the gas dialysis membrane and subsequently trapped in a dilute sodium hydroxide receiving stream. This stream is reacted with N,N-dimethyl-p-phenylenediamine and ferric chloride to produce methylene blue which is then quantitated colorimetrically at 660 nm. For standards and nonturbid environmental samples, there is good agreement between the results obtained by this procedure and the standard methylene blue method. The effect of interferences on the accurate determination of sulfide by both methods was also examined and it was found that cupric ions significantly interfered with sulfide estimation. To obtain ...

1990-01-01

437

Analysis of pesticides in dried hops by liquid chromatography-tandem mass spectrometry.  

Science.gov (United States)

An analytical method was developed for the determination of eleven agrochemicals [abamectin (as B1a), bifenazate, bifenthrin, carfentrazone-ethyl, cymoxanil, hexythiazox, imidacloprid, mefenoxam, pymetrozine, quinoxyfen, and trifloxystrobin] in dried hops. The method utilized polymeric and NH2 solid phase extraction (SPE) column cleanups and liquid chromatography with mass spectrometry (LC-MS/MS). Method validation and concurrent recoveries from untreated dried hops ranged from 71 to 126% for all compounds over three levels of fortification (0.10, 1.0, and 10.0 ppm). Commercially grown hop samples collected from several field sites had detectable residues of bifenazate, bifenthrin, hexythiazox, and quinoxyfen. The control sample used was free of contamination below the 0.050 ppm level for all agrochemicals of interest. The limit of quantitation and limit of detection for all ...

2008-07-02

438

Untersuchung von Bildqualitat und Genauigkeit der Dosisberechnung bei cone-beam-CT-Aufnahmen mit reduziertem Projektionsdatensatz (half scan, half fan) im Hinblick auf die Verwendbarkeit fur die adaptive Bestrahlungsplanung  

British Library Electronic Table of Contents (United Kingdom)

Subject of this study is the question of whether cone beam CT (CBCT) images with reduced projection data are suitable for use in adaptive radiation therapy (ART) treatment planning. For this purpose image quality and dose calculation accuracy depending on imaging modality were analysed. In this context, two CBCT-methods will be indicated having reduced projection data sets: Scans acquired with 200^o rotation angle in order to accelerate the CBCT process (half scan), or scans with an asymmetric cone beam and detector offset, used to enlarge the field-of-view (half fan). Methods: For three different CBCT-modes (On-Board-Imaging, Varian Medical Systems), two of them based on reduced projection data, and a conventional multidetector CT system, the main image quality parameters were studied. Tr...

2011-01-01

439

The application of irradiation techniques for food preservation and processing improvement  

Energy Technology Data Exchange (ETDEWEB)

This project has intended to develop alternative techniques to be used in food industry for food processing and utilization by safe irradiation methods. For improvement of rheology and processing in corn starch by irradiation, the production of modified starch with low viscosity as well as with excellent viscosity stability became feasible by the control of gamma irradiation dose levels and the amount of added inorganic peroxides to starch. Also, this project was developed the improvement methods of hygienic quality and long-term storage of dried red pepper by gamma irradiation. And, in Korean medicinal plants, 10 kGy gamma irradiation was effective for improving sanitary quality and increasing extraction yield of major components. For the sanitization of health and convenience foods, gamma irradiation was more effective than ozone treatment in decontamination of microorganisms, with minimal effect on ...

1997-09-01

440

Phosphorus and nitrogen in the eutrophication of waters. Fosfori ja typpi vesien rehevoeittaejinae - vaikutusten arviointi  

Energy Technology Data Exchange (ETDEWEB)

This report is a summary of the contribution of nitrogen and phosphorus in the eutrophication process of inland and coastal waters. Special attention was paid to the mechanisms of these nutrients in regulating biological processes and to the methods available in estimating their effects in the eutrophication of water bodies. The report includes five chapters which are entitled: Introduction, which is a general background to the subject with special attention to the requirements of the Finnish Water Act. Phosphorus and nitrogen as factors regulating biological processes. The topics included are: definition of eutrophication, forms of phosphorus and nitrogen and their sources to inland and coastal waters, effects of these nutrients as growth factors of phytoplankton and macrophytes and consequences of eutrophication. Estimation of the effects of phosphorus and nitrogen. The topics discussed from the point of view of the tasks of the National Board of Waters and the ...

1992-01-01

441

Nuclear forensics-metrological basis for legal defensibility  

International Nuclear Information System (INIS)

The admissibility of nuclear forensics measurements and opinions derived from them in US Federal and State courts are based on criteria established by the US Supreme Court in the case of Daubert v. Merrell Dow and the 2000 Amendment of Rule 702 of the Federal Rules of Evidence. These criteria are being addressed by new efforts that include the development of certified reference materials (CRMs) to provide the basis for analytical method development, optimization, calibration, validation, quality control, testing, readiness, and declaration of measurement uncertainties. Quality data is crucial for all stages of the program, from R and D, and database development, to actual casework. Weakness at any point in the program can propagate to reduce the confidence of final conclusions. The new certified reference materials will provide the necessary means to demonstrate a high level of metrological rigor for nuclear forensics ...

2009-12-01

442

Material and process improvements in condenser tubing  

Energy Technology Data Exchange (ETDEWEB)

The reliability of the surface condenser is a key factor in plant performance level and maintenance cost optimization. This is especially the case for thermal nuclear plants where condenser raw wa-ter ingress can introduce contamination into the chemically-controlled, steam/water loop potentially causing damage to sensitive equipment. Two important parameters must be taken into account when attempting to optimize the quality and the reliability of condenser tubing. They include selecting the appropriate material according to the cooling water corrosion level present. A second and equally important parameter is the manufac-turing of the tubing product itself. This paper will identify methods to optimize manufacturing processes and improve tubing quality, according to VALTIMET's 30 years of condenser welded tubing production experience. Those methods complete the core manufacturing process ...

2010-07-01

443

Different purification methods and quality of sunflower biodiesel  

Energy Technology Data Exchange (ETDEWEB)

Biodiesel is derived from triacylglycerides and is produced primarily through transesterification, a chemical reaction of vegetable oils with alcohol, methanol or ethanol. The cost of raw material should be considered since 85 per cent of production cost is related to vegetable oil. The purpose of this study was to evaluate oil expression of sunflower seed. It also examined the sunflower crude oil as a raw material for biodiesel by transesterification in both laboratory and pilot scale studies. Three different biodiesel purification methods were examined. The best result for oil expelling (68.4 per cent) at the experimental stage was obtained for seeds with a moisture content of 6.9 per cent at 25 degrees C and at a screw speed of 114 rpm. For biodiesel production at the laboratory scale, the best result for oil expelling was 87.5 per cent. It was obtained with an ethanol:oil molar ratio of 4.7:1 and with a 4.42 per cent catalyst concentration related to the ...

2010-07-01

444

Determination and characteristics of the transition to two-phase slug flow in small horizontal channels  

Energy Technology Data Exchange (ETDEWEB)

Two-phase pressure drop and fluctuating static pressures were measured in a small horizontal rectangular channel (hydraulic diameter = 5.44 mm). The two-phase fluid was an air/water mixture at atmospheric pressure tested over a mass flux range of 50 to 2,000 kg/m[sup 2] [center dot] s. Two-phase flow patterns were identified and an objective method was found for determining the flow pattern transition from bubble or plug flow to slug flow. The method is based on an RMS static pressure measurement. In particular, it is shown that the transition is accompanied by a clear and abrupt increase in the RMS pressure when plotted as a function of mass quality. Use of the RMS pressure as a two-phase flow pattern transition indicator is shown to have advantages over pressure-versus-time trace evaluations reported in the literature. The transition is substantiated by a clear local change in slope in the curve of two-phase pressure drop ...

1994-03-01

445

Challenges in validating the sterilisation dose for processed human amniotic membranes  

Energy Technology Data Exchange (ETDEWEB)

Most of the tissue banks in the Asia Pacific region have been using ionising radiation at 25 kGy to sterilise human tissues for save clinical usage. Under tissue banking quality system, any dose employed for sterilisation has to be validated and the validation exercise has to be a part of quality document. Tissue grafts, unlike medical items, are not produced in large number per each processing batch and tissues relatively have a different microbial population. A Code of Practice established by the International Atomic Energy Agency (IAEA) in 2004 offers several validation methods using smaller number of samples compared to ISO 11137 (1995), which is meant for medical products. The methods emphasise on bioburden determination, followed by sterility test on samples after they were exposed to verification dose for attaining of sterility assurance level (SAL) of 10{sup -1}. This paper describes our ...

2007-11-15

446

Bisulfite genomic sequencing of DNA from dried blood spot microvolume samples.  

Science.gov (United States)

DNA methylation is an important event in epigenetic changes in cells, and a fundamental regulator of gene transcription. Bisulfite genomic sequencing is a powerful technique used in studies of DNA methylation. However, the established procedures often require relatively large amounts of DNA. In everyday practice, samples submitted for analysis might contain very small amounts of poor quality material, as is often the case with forensic stain samples. In this study, we assess a modified, more efficient method of bisulfite genomic sequencing. Genomic DNA extracted from 3-mm dried blood spots using QIAamp micro kit was treated with sodium bisulfite (using EpiTect kit). Subsequent methylation-specific PCR (MSP) followed by DNA sequencing displayed the differentially methylated region of imprinted gene SNRPN. Our results show that this new combination of efficient DNA extraction and bisulfite treatment provides high quality ...

2011-07-01

447

Assisted reproductive technologies for male factor infertility.  

Science.gov (United States)

Experience in the diagnosis and treatment of infertility has led to an increased understanding of the prominent role male factors play in many couples' inability to conceive. While many forms of male factor infertility are amenable to treatment, for some patients there is no corrective therapy available. For this reason, a great deal of attention has been focused on developing technologies for semen processing and sperm utilization in cases of decreased semen quality. One area of research is the development of more sophisticated methods of assessing sperm function, as well as methods of sperm preparation. Progress is also being made in the application of technologies such as intrauterine insemination and in vitro fertilization in the treatment of male factor infertility. Such developments have improved prospects for fertility among patients suffering from decreased semen quality, as well as those ...

1991-10-01

448

The importance of radiation quality for optimisation in radiology  

UK PubMed Central (United Kingdom)

Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available

449

Spray-formed tooling and aluminum strip  

Energy Technology Data Exchange (ETDEWEB)

Spray forming is an advanced materials processing technology that converts a bulk liquid metal to a near-net-shape solid by depositing atomized droplets onto a suitably shaped substrate. By combining rapid solidification processing with product shape control, spray forming can reduce manufacturing costs while improving product quality. De Laval nozzles offer an alternative method to the more conventional spray nozzle designs. Two applications are described: high-volume production of aluminum alloy strip, and the production of specialized tooling, such as injection molds and dies, for rapid prototyping.

1995-11-01

450

Polyurethane - positioning aids in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

A simple and cheap method is described for the manufacturing of individual positioning aids made of foamed polyurethane. Some examples are given to demonstrate the applicability of these positioning aids for the irradiation of different body regions. The reproducibility of the radiation field in the head and neck area was investigated with and without positioning aid. It was proved that the field is adjusted more exactly when positioning aids are applied. The dosimetric investigations performed showed a negligible influence of foamed polyurethane on the radiation quality. So the positioning aids could be left within the radiation field when drawing the field borders.

1985-06-01

451

Heating-cooling ceilings and cold beams; Plafonds chauffants-rafraichissants et poutres froides  

Energy Technology Data Exchange (ETDEWEB)

The aim of this document is to make a state-of-the-art of the techniques of heating-cooling ceilings and cold beams. These systems offer many advantages: they generate a high quality thermal comfort, they are energy efficient, and offer important room saving, particularly interesting in the case of building renovation. The document comprises 5 parts dealing with: 1 - the heating-cooling ceilings; 2 - the cold beams; 3 - the elements necessary for the dimensioning (building-system interactions, ventilation, temperature regulation and safety systems); 4 - dimensioning method; 5 - design, realization and operation: the rules to follow. (J.S.)

2004-07-01

452

Employing exergy-optimized pin fins in the design of an absorber in a solar air heater  

Energy Technology Data Exchange (ETDEWEB)

Fins serve as heat transfer augmentation features in solar air heaters; however, they increase pressure drop in flow channels. Pin fins are relatively good heat transfer augmentation features with superior aerodynamic performance, and as a result find application in some solar air heaters. The exergy optimization method is employed in sizing the pin fin. Results indicate that high efficiency of the optimized fin improves the heat absorption and dissipation potential of a solar air heater. With optimum fin efficiency and superior absorptive coating quality, useful energy losses can be minimized. Some important observations pertinent in design are made. (author)

2010-02-15

453

Efficient Cartesian-grid-based modeling of rotationally symmetric bodies  

DEFF Research Database (Denmark)

Axially symmetric waveguides, resonators, and scatterers of arbitrary cross section and anisotropy in the cross section can be modeled rigorously with use of 2-D Cartesian-grid based codes by means of mere redefinition of material permittivity and permeability profiles. The method is illustrated by the frequencydomain simulations of resonant modes in a circular-cylinder cavity with perfectly conducting walls, a shielded uniaxial anisotropic dielectric cylinder, and an open dielectric sphere for which, after proper implementation of the perfectly matched layer boundary conditions, the radiation quality factor is also determined.

2007-01-01

454

Effects of variable hardness, ph, alkalinity, suspended clay, and humics on the chemical speciation and aquatic toxicity of copper  

Science.gov (United States)

The effects of variable hardness, pH, alkalinity, humics, and suspended clay on the chemical speciation of copper and its toxicity to fathead minnow larvae in Lake Superior water were investigated. Two proposed methods (toxicity factors and chemical speciation) for predicting LC50 values in specific natural waters from laboratory toxicity data and the average site specific values of general water quality parameters were evaluated. The accuracy of the cupric ion-selective electrode in determining CU/sup +2/ activities in ambient and chemically altered Lake Superior water was also determined.

1986-03-01

455

Does energy substitution affect carbon dioxide emissions - Income relationship?  

British Library Electronic Table of Contents (United Kingdom)

Considerable discussion has taken place during the last decade regarding the role of economic growth in determining environmental quality. Using data from 30 OECD countries for the period 1960-2003 and the nonparametric method of generalized additive models, which enables us to use flexible functional forms, this paper examines the environmental Kuznets curve hypothesis for carbon dioxide (CO2). We find that the reduction of coal share in energy use has a significant effect on CO2. Our results imply that economic growth is not sufficient to decrease CO2 emissions.

2010-01-01

456

Core preservation with a laminated, heat-sealed package  

Energy Technology Data Exchange (ETDEWEB)

A core preservation package was developed to maintain the reservoir characteristics of core samples and consequently to improve the quality of data obtained through laboratory core analyses. The package is a heat-sealable plastic-aluminum laminate similar to those common in the food-packaging industry. The laminated core preservation package acts as an impermeable barrier to water vapor and gases, and is resistant to chemical alteration and degradation by core fluids. These performance characteristics result in effective core preservation by maintaining the fluid content of the core. Other advantages of the laminated package are that it is fast and simple to use and eliminates the cumbersome dip-coat step used in some core preservation methods.

1988-12-01

457

Boring of full scale deposition holes using a novel dry blind boring method  

Energy Technology Data Exchange (ETDEWEB)

As a part of the Finnish radioactive waste disposal research three holes (the size of deposition holes) were bored in the research tunnel at Olkiluoto in Finland. A novel full-face boring technique was used based on rotary crushing of rock and removal of crushed rock by vacuum flushing through the drill string an the purpose of the work was to demonstrate the feasibility of the technique. During the boring test procedures were carried out in order to determine the effect of charges in operating parameters on the performance of the boring machine and the quality of the hole. (refs.).

1996-11-01

458

Biogas supply to the natural gas supply grid. Study; Einspeisung von Biogas in das Erdgasnetz. Studie  

Energy Technology Data Exchange (ETDEWEB)

Biogas supply to the public gas grid is a new option discussed in the most recent publication of Fachagentur Nachwachsende Rohstoffe (FNR) e.V. The biogas is purified, upgraded to natural gas quality and fed into an existing gas grid. Once there, it can be transported across long distances and also used for electric power generation at the consumer side. The study investigates inhowfar and in what instances this method is feasible and promising. It discusses the technical background and the regional potential of biogas. Seven model biogas systems are presented as examples. (orig.)

2006-07-01

459

Angular scattering in electron capture and loss D/sup -/ beam formation processes  

Energy Technology Data Exchange (ETDEWEB)

The development of high energy (> 150 keV) neutral beams for heating and fueling magnetic fusion devices depends on the ability to produce well-collimated negative ion beams. The double capture charge-exchange technique is a known, scalable method. In order to maximize the overall efficiency of the process and to achieve the desired beam characteristics, it is necessary to examine the optical qualities of the beams as well as the total efficiency of beam production. A combined modeling and experimental study of the angular scattering effects in negative ion formation and loss processes has therefore been undertaken.

1980-01-01

460

Anaerobic digestion of municipal solid waste: Technical developments  

Energy Technology Data Exchange (ETDEWEB)

The anaerobic biogasification of organic wastes generates two useful products: a medium-Btu fuel gas and a compost-quality organic residue. Although commercial-scale digestion systems are used to treat municipal sewage wastes, the disposal of solid organic wastes, including municipal solid wastes (MSW), requires a more cost-efficient process. Modern biogasification systems employ high-rate, high-solids fermentation methods to improve process efficiency and reduce capital costs. The design criteria and development stages are discussed. These systems are also compared with conventional low-solids fermentation technology.

1996-01-01

461

An investigation of passive ventilation cooling and control strategies for an educational building  

Energy Technology Data Exchange (ETDEWEB)

Many non-domestic buildings, built recently in the UK, use natural means to provide ventilation for indoor air quality and thermal comfort. This paper presents monitoring results obtained from such a purpose built naturally ventilated educational building. Its performance during the summer is discussed based on monitored results. Using thermal and ventilation modelling, the paper also discusses the optimisation of the building's summer performance. Recommendations on the selection of appropriate ventilation strategies in relation to the prevailing external conditions are derived and the appropriateness of the control methods is discussed. (author)

2001-02-01

462

Quality assurance handbook for measurement laboratories  

International Nuclear Information System (INIS)

This handbook provides guidance in the application of quality assurance to measurement activities. It is intended to help those persons making measurements in applying quality assurance to their work activities by showing how laboratory practices and quality assurance requirements are integrated to provide control within those activities. The use of the guidance found in this handbook should help provide consistency in the interpretation of quality assurance requirements across all types of measurement laboratories. This handbook also can assist quality assurance personnel in understanding the relationships between laboratory practices and quality assurance requirements. The handbook is composed of three chapters and several appendices. Basic guidance is provided by the three chapters. In Chapter 1, the role of quality assurance in obtaining ...

463

An efficient method for 3-D pre stack migration in time reverse-time depth by using finite difference method; Um metodo eficiente para migracao pre-empilhamento 3-D em profundidade reversa no tempo pelo metodo das diferencas finitas  

Energy Technology Data Exchange (ETDEWEB)

Much of the current technology on 3D-prestack depth migration is based on the Kirchhoff method and the traveltime information needed for this purpose is obtained by the ray-theory approximation. The main motivation driving these options is to reduce computations but it can also have an adverse effect on the quality of results. Experience with real data indicates that the corresponding poststack data migrated by the reverse-time method often yields superior results. Considerable computational efficiency can be obtained by employing nonuniform coarse grid spacing during the reverse-time migration. We followed this strategy for developing a parallel scheme for doing 3D- prestack depth migration. However, we worked only on a small subset of shot gathers whose determined by the Quasi-Monte Carlo method. The results were indistinguishable from those obtained by using a much larger population of uniformly ...

1997-07-01

464

The optimization of gamma spectra processing in prompt gamma neutron activation analysis (PGNAA)  

International Nuclear Information System (INIS)

The uncertainty of the elemental analysis is one of the major factors governing the utility of on-line Prompt Gamma Neutron Activation Analysis (PGNAA) in the blending and sorting of bulk materials. In this paper, a general method applicable to Gamma spectra processing is presented and applied to PGNAA in mineral industry. Based on the Fourier transform of spectra and their de-correlation in the Fourier space (the improvement of the conditioning of the correlation matrix), processing of overlapping of characteristic peaks minimizes the propagation of random errors, which optimizes the accuracy and decreases the detection limits of elemental analyses. In comparison with classical methods based on the linear combinations of relevant regions of spectra the improvement may be considerable, especially when several elements are interfering. The method is applied to four case stories covering both borehole ...

2009-04-15

465

Magnetic resonance imaging in joint diseases  

International Nuclear Information System (INIS)

Magnetic resonance imaging has proven an invaluable method in the diagnosis of joint diseases associated with osteonecrotic, inflammatory, traumatic and degenerative processes. At the clinical level, it has an important role in decisions about the method of treatment and evaluations of the therapeutic success. When the merits of MRT are balanced against those of conventional radiography including tomography and CT, which both ensure better spatial resolution in the visualisation of cortical and spongy bone structures, it becomes quite evident that MRT must not be regarded as an alternative method of imaging but as one that can be used additionally to obtain the most information for the diagnosis of arthropathy. The question as to whether new pulse sequences (snap shots) or invasive techniques like intra-articular injection of paramagnetic substances (MR arthrography) are likely to become routine procedures in the ...

466

A liquid chromatography?fluorimetric method for the in vitro estimation of the skin penetration of disodium phenyldibenzimidazole tetrasulfonate from sunscreen formulations through human skin  

British Library Electronic Table of Contents (United Kingdom)

Disodium phenyldibenzimidazole tetrasulfonate (PDT) is a new organic UV filter with hydrophilic properties used in modern sunscreen spray formulations. The aim of this work was to develop and validate an analytical method that can be used to study skin absorption of PDT from sunscreens. Results obtained in vitro for human skin showed a low level of absorption. The proposed in vitro method employs a diffusion cell. Sunscreen lotion was applied onto pretreated human skin, which was then placed in the cell. PDT was collected in a receptor liquid, the surface of which was in contact with the skin. The solutions obtained were diluted appropriately and analyzed by liquid chromatography without any interference. The analytical features of chromatographic determination with fluorimetic detection w...

2006-01-01

467

Limitations of traveling wave relaying for overhead EHV transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Limitations of traveling wave relaying schemes for protection of overhead extra-high voltage transmission lines are investigated. A method of analysis of traveling wave phenomena for three phase transmission lines is developed in which the interdependent phase voltages and currents are decoupled into their modal counterparts, which are approximately independent. A time domain digital simulation program is used to solve the modal transmission line equations to obtain the fault induced traveling waves detected at the relay location. The frequency dependence of the aerial modes is ignored but their losses are included. A lumped element analysis method, originally developed for transient analysis of lossy coaxial cables, is adapted here to obtain approximate solution for the fault induced traveling waves of the ground mode. Excellent agreement is found between the results obtained by this method and ...

1986-01-01

468

Traces of evidence. Nuclear forensics and illicit trafficking  

International Nuclear Information System (INIS)

An IAEA databank lists a number of reported cases of illicitly trafficked nuclear or other radioactive materials. Apart from the traditional concern with nuclear proliferation, the post September 11th public is now wary of a possible attack by terrorists with a nuclear or radiation dispersion device (RDD). Until now, the seized quantities have not been sufficient to manufacture a nuclear explosive device, but they might be enough to construct an RDD. Recognizing the latent global challenge to public health and safety, the G8 States (Japan, USA, Germany, France, UK, Italy, Canada, and Russia) have called for 'joint international efforts to identify and suppress illicit supply' of, and demand for, nuclear material and to deter potential traffickers. One measure gaining in significance is to identify seized material and trace it back to its origin the objective of an emerging science known as nuclear forensics. Repeatedly nuclear or other radioactive material of unknown origin are ...

2003-06-01

469

Intelligent Extruder  

Energy Technology Data Exchange (ETDEWEB)

''Intelligent Extruder'' described in this report is a software system and associated support services for monitoring and control of compounding extruders to improve material quality, reduce waste and energy use, with minimal addition of new sensors or changes to the factory floor system components. Emphasis is on process improvements to the mixing, melting and de-volatilization of base resins, fillers, pigments, fire retardants and other additives in the :finishing'' stage of high value added engineering polymer materials. While GE Plastics materials were used for experimental studies throughout the program, the concepts and principles are broadly applicable to other manufacturers materials. The project involved a joint collaboration among GE Global Research, GE Industrial Systems and Coperion Werner & Pleiderer, USA, a major manufacturer of compounding equipment. Scope of the program included development ...

2003-04-24

470

Chemical, sensory and microbiological changes of gamma irradiated coconut cream powder  

Energy Technology Data Exchange (ETDEWEB)

A study was carried out to determine optimum decontamination dose for a locally manufactured coconut cream powder. Samples were gamma irradiated (0-15 kGy) and ageing process was achieved using GEER oven at 60 deg. C for 7 days, which is equivalent to one-year storage at room temperature. Iodine value (IV), ranging from 4.8 to 6.4, was not affected by radiation doses and storage, however peroxide value and thiobarbituric acid (TBA) generally increased with radiation doses. In most samples, peroxide value (meq/kg) reduced after storage, whilst the TBA (mg malonaldehyde/kg), indicator for product quality, slightly increased. The sensory evaluation conducted using 25 taste panellists indicated that scores on odour, creamy taste and overall acceptance for all irradiated samples at more than 5 kGy were significantly lower (P<0.05) than the control. However, the panellists could not detect any significant differences among the irradiation ...

2007-11-15

471

A study of neutron room scattering at RPCF  

International Nuclear Information System (INIS)

High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers dosimeters use CR39 for neutron detection, ...

1997-01-05

472

A study of neutron room scattering at RPCF  

Energy Technology Data Exchange (ETDEWEB)

High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers dosimeters use CR39 for neutron detection, ...

1996-09-01

473

Ultrasensitive fluorescence detection of DNA  

Science.gov (United States)

Progress on Ultrasensitive fluorescence detection of DNA is briefly described. (CBS)

1991-01-01

474

Fluorescent Silicate Materials for the Detection of Paraoxon  

Science.gov (United States)

... significantly lower limits of detection. The complex fluorescence spectra of these constructs indicated that only a portion ...

2010-03-19

475

Thermal modelling of underground coal fires in Northern China  

Energy Technology Data Exchange (ETDEWEB)

The thesis describes work undertaken as part of a larger remote sensing based project which aims to detect, measure and monitor coal fires in two test areas in northern China. The first main topic addressed in this thesis is the detection of fires using several different thermal remote sensing data sets. The synergistic use of the different data sets is emphasised. The second major part of the thesis deals with thermal modelling of the coal fires. Three different models are developed, which allow a fire's depth, temperature, extent, total heat output and rate of movement to be determined. The models are tested both in the laboratory and using various field data sets. A model based on the assumption that the fire is a point heat source and that the temperature distribution around it is spherically symmetrical is shown to be the most effective. A simpler, one-dimensional coal fire model and a model based on the finite element ...

1998-07-01

476

Tau Boo b: Hunting for reflected starlight  

CERN Document Server

Aims. We attempt to detect starlight reflected from the hot Jupiter orbiting the main-sequence star Tau Boo, in order to determine the albedo of the planetary atmosphere, the orbital inclination of the planetary system and the exact mass of the planetary companion. Methods. We analyze high-precision, high-resolution spectra, collected over two half nights using UVES at the VLT/UT2, by way of data synthesis. We interpret our data using two different atmospheric models for hot Jupiters. Results. Although a weak candidate signal appears near the most probable radial velocity amplitude, its statistical significance is insufficient for us to claim a detection. However, this feature agrees very well with a completely independently obtained result by another research group, which searched for reflected light from Tau Boo b. As a consequence of the non-detection of reflected light, we place upper limits to the ...

2010-01-01

477

Safety assessment and life time management of nuclear power plants: from reasonable design to reliable structural health monitoring  

International Nuclear Information System (INIS)

Nowadays the safety of Nuclear Power Plants is becoming more and more significant. Therefore consideration of severe accidents shall be included in both design and operating process of Nuclear Power Plants. In particular ground motion forms one of the important natural hazards. For structural analysis both linear-elastic and non-linear methods are specified by the engineering codes for earthquake resistance design. However, time history analysis is required for investigation of non-linear structural behaviour. Moreover, non-linearities are often caused by the presence of damage. This can be detected by means of structural health monitoring and subsequently system identification. In this paper the advantages of both dynamic time history analysis and damage detection by means of wavelet analysis are discussed. First, the non-linear behaviour of a frame structure due to an artificial earthquake motion is analyzed. A comparison ...

2005-06-15

478

Iterative Dense Correspondence Correction Through Bundle Adjustment Feedback-Based Error Detection  

Energy Technology Data Exchange (ETDEWEB)

A novel method to detect and correct inaccuracies in a set of unconstrained dense correspondences between two images is presented. Starting with a robust, general-purpose dense correspondence algorithm, an initial pose estimate and dense 3D scene reconstruction are obtained and bundle-adjusted. Reprojection errors are then computed for each correspondence pair, which is used as a metric to distinguish high and low-error correspondences. An affine neighborhood-based coarse-to-fine iterative search algorithm is then applied only on the high-error correspondences to correct their positions. Such an error detection and correction mechanism is novel for unconstrained dense correspondences, for example not obtained through epipolar geometry-based guided matching. Results indicate that correspondences in regions with issues such as occlusions, repetitive patterns and moving objects can be identified and corrected, such that a more ...

2009-11-23

479

Inspection of PFR steam generators  

International Nuclear Information System (INIS)

The inspection of PFR evaporator tubing, superheater and reheater tubing, and tube plate examinations, are described. Ferritic steel U tubes in the evaporator have been examined by an eddy current system operating at 400 kHz using flexible rotating probes. Surface defects as shallow as 0.1 mm can be detected and sized in the range 0.1 to 0.5 mm deep. An ultrasonic method is under development for wall thickness. Special test coil probes have been developed for examination of the type 316 stainless steel superheater and reheater tubing. Crack-life defects in the bore are detectable at approximately 10% wall thickness and 20% on the outside diameter. Tube plate examinations from the tube holes, have been conducted using eddy current probes which identify surface breaking cracks in the holes. For detecting curtain cracks between tube plate holes, ultrasonic compression wave probes have been used. (U.K.).

1976-03-09

480

Experience with abdominal gamma imaging in patients with bleeding of the lower digestive tube  

International Nuclear Information System (INIS)

This study concerns our experiences with abdominal gamma imaging using Tc-99m colloid and with abdominal angiography using Tc-99m-pyrophosphate labelled erythrocytes ''in vivo'' based on the modified technique described by Callahan. The dynamic or perfusion phase was first performed, then the static phase during which for the first two hours scans were taken every 15 minutes and thereafter every 4-6 hours. The routine image corresponds to the first, although it was necessary at times to take oblique projections. The study was felt to be accomplished after 48 hours upon observing no extravasation of radioactive material in the abdominal region, or upon detecting a bleeding site. The investigation was performed on 11 patients, 8 having positive scans of abdominal extravasation, later confirmed in 6 by endoscopy and by surgery. In 2, the presence of salmonelosis was shown by laboratory analysis. Endoscopy and angiography XR are both invasor ...

1985-04-25

481

Detection of the heavy Higgs boson at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We consider the possibility of detecting a heavy Higgs boson (m_H>2m_Z) in proposed #gamma##gamma# colliders through the semileptonic mode #gamma##gamma##->#H#->#ZZ#->#q bar ql"+l-. We show that due to the nonmonochromatic nature of the photon beams produced by the laser-backscattering method, the resultant cross section for Higgs production is much smaller than the on-resonance cross section, and generally decreases with increasing collider energy. Although continuum ZZ production is expected to be negligible, we demonstrate the presence of, and calculate sizable backgrounds from, #gamma##gamma##->#l"+l-Z,q bar qZ, with Z#->#q bar q,l"+l-, respectively, and #gamma##gamma##->#t bar t#->#b bar bl"+l-#nu# bar #nu#. This channel may be used to detect a Higgs boson of mass m_H up to around 350 GeV at a 0.5 TeV e"+e- collider, assuming a nominal yearly luminosity of 10--20 fb"-"1.

482

Containment of genetically engineered organisms after application to subsurface environments. Technical completion report  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of containing genetically engineered bacteria with enhanced dehalogenating properties for in situ bioremediation was investigated. (1) An agarose matrix microbead protocol and a detection system for contained microorganisms or DNA were developed. Multiplex Polymerase Chain Reaction (PCR) allowed tracking of a consortium of encapsulated organisms or several gene targets from a single species. Gene sequences encoding the enzymes responsible for initiating the biodegradation of toluene, octane, and 2,4-D were detected by multiplex PCR and nucleic acid probes from similar to 1-10 biodegradative cells/g soil. Improved DNA extraction methods resulted in PCR reactions detecting similar to 6 cells/g soil. (2) The pcpB gene (for the broad-spectrum detoxicant pentachlorophenol (PCP) hydroxylase) isolated from Flavobacterium sp. strain ATCC 39723 was used in attempts to develop an improved ...

1993-06-01

483

Community Detection using a Measure of Global Influence  

CERN Document Server

The growing popularity of online social networks has provided researchers with access to large amount of social network data. This, coupled with the ever increasing computation speed, storage capacity and data mining capabilities, led to the renewal of interest in automatic community detection methods. Surprisingly, there is no universally accepted definition of the community. One frequently used definition states that ``communities, that have more and/or better-connected `internal edges' connecting members of the set than `cut edges' connecting the set to the rest of the world''[Leskovec et al. 20008]. This definition inspired the modularity-maximization class of community detection algorithms, which look for regions of the network that have higher than expected density of edges within them. We introduce an alternative definition which states that a community is composed of individuals who have more influence on others ...

2008-01-01

484

Coal mine fire inventory and monitoring in Jharia coalfield Bihar, India, using thematic mapper thermal IR data  

Energy Technology Data Exchange (ETDEWEB)

Largest coal mine fires in the world are reported from Jharia coalfield in Dhanbad district, Bihar State of India. In this paper we report the utility of day and night time Thematic Mapper thermal IR data (120 m x 120 m) for detecting and monitoring mine fires in Jharia. For this purpose, seven sets of TM data acquired between 1985 to 1995 have been analysed. Data processing methods include geometric and radiometric corrections, conversion of DN values to at-satellite temperatures and colour coding of temperature images. The pixel-integrated temperatures of 50{degrees}C and above have been classified as mine fires and achieved an accuracy of 81.2%. Also, assessed year wise, colliery-wise and geological formation-wise mine fire distribution in this area. Although TM thermal data is of coarser resolution, it enabled detection of mine fires mainly because of the large areal extent and high temperature range of mine fires. It ...

1996-08-01

485

Use of electron beam irradiation to improve the microbiological safety of Hippophae rhamnoides  

Energy Technology Data Exchange (ETDEWEB)

Sea buckthorn (Hippophae rhamnoides) is increasingly used in food supplements due to its dietary and medicinal compounds with a beneficial role in human diet and health. As many other medicinal plants, sea buckthorn can be contaminated with microorganisms which exerts an important impact on the overall quality of the products. Irradiation is an effective method for food preservation because it is able to destroy pathogenic microorganisms keeping the organoleptic and nutritional characteristics of the foods. The objective of the present study was to investigate the application of electron beam irradiation in order to improve the microbiological safety of sea buckthorn. The experimental results indicated that the electron beam treatment might be a good method to remove undesirable microorganisms from sea buckthorn without significant changes in its active principles.

2007-09-21

486

Measurement of the ratio of liquid to solid phases in a continuous ingot  

International Nuclear Information System (INIS)

A radiometric method of measuring the ratio of liquid and solid phases (crust thickness) in a continuous ingot for automation of the continuous steel casting process, has been proposed. The essence of the method is, that radiation flux, bearing information on the object tested, is transformed in a succession of electric pulses, which is processed afterwords for obtaining necessary information. In this case either the flux of non-scattered radiation, passed through the object, or the flux of single-scattered radiation reflected from the object is registered. Block-diagram and specifications of a radiometric device with the Co source of 50 gxequiv. Ra activity developed for this purpose are presented. The technique for calibration ob the device and the results of its tests, are described. It is shown, that introduction of such devices for the control crust thickness at the installations of continuous steel casting of metallurgical works would ...

487

Industrial application of green chromatography-I. Separation and analysis of niacinamide in skincare creams using pure water as the mobile phase  

British Library Electronic Table of Contents (United Kingdom)

In this work, chromatographic separation of niacin and niacinamide using pure water as the sole component in the mobile phase has been investigated. The separation and analysis of niacinamide have been optimized using three columns at different temperatures and various flow rates. Our results clearly demonstrate that separation and analysis of niacinamide from skincare products can be achieved using pure water as the eluent at 60^oC on a Waters XTerra MS C18 column, a Waters XBridge C18 column, or at 80^oC on a Hamilton PRP-1 column. The separation efficiency, quantification quality, and analysis time of this new method are at least comparable with those of the traditional HPLC methods. Compared with traditional HPLC, the major advantage of this newly developed green chromatography techniq...

2011-01-01

488

Estrogen and raloxifene improve metaphyseal fracture healing in the early phase of osteoporosis. A new fracture-healing model at the tibia in rat  

British Library Electronic Table of Contents (United Kingdom)

Background Fracture healing in osteoporosis is delayed. Quality and speed of fracture healing in osteoporotic fractures are crucial with regard to the outcome of patients. The question arises whether established antiosteoporotic drugs can further improve fracture healing. Materials and methods Osteoporosis manifests predominantly in the metaphyseal bone. Nevertheless, an established metaphyseal fracture model is lacking. A standardized metaphyseal fracture-healing model with stable plate fixation was developed for rat tibiae. The healing process was analyzed by biomechanical, gene expression, and histomorphometric methods in ovariectomized (OVX) and sham-operated rats (SHAM), compared to standardized estrogen (E)- and raloxifene (R)-supplemented diets. Results Estrogen and raloxifene impro...

2010-01-01

489

A report on collective ion acceleration via space charge waves on intense relativistic electron beams  

Science.gov (United States)

Collective methods of ion acceleration using intense relativistic electron beams (IREB) have stimulated a great deal of interest in the past few years. The main virtue of an IREB collective ion accelerator is the high internal electric field strength. The primary drawback has been an insufficient ion energy gain or inadequate scaleability. An extensive study for generating a high quality electron beam has been done and is presented in Section 2. In Section 3 an intense ion injector study was conducted by the method of computer simulation. The last addition to the proposal was a design for producing a toroidal magnetic field. This field will be needed in a future study of high energy and high current electron beams.

1981-02-01

490

A Trajectory Correction based on Multi-Step Lining-up for the CLIC Main Linac  

CERN Document Server

In the CLIC main linac it is very important to minimise the trajectory excursion and consequently the emittance dilution in order to obtain the required luminosity. Several algorithms have been proposed and lately the ballistic method has proved to be very effective. The trajectory method described in this Note retains the main advantages of the latter while adding some interesting features. It is based on the separation of the unknown variables like the quadrupole misalignments, the offset and slope of the injection straight line and the misalignments of the beam position monitors (BPM). This is achieved by referring the trajectory relatively to the injection line and not to the average pre-alignment line and by using two trajectories each corresponding to slightly different quadrupole strengths. A reference straight line is then derived onto which the beam is bent by a kick obtained by moving the first quadrupole. The other quadrupoles are ...

1999-01-01

491

In-situ measurement of epithelial tissue optical properties: Development and implementation of diffuse reflectance spectroscopy techniques  

Science.gov (United States)

Cancer is a severe threat to human health. Early detection is considered the best way to increase the chance for survival. While the traditional cancer detection method, biopsy, is invasive, noninvasive optical diagnostic techniques are revolutionizing the way that cancer is diagnosed. Reflectance spectroscopy is one of these optical spectroscopy techniques showing promise as a diagnostic tool for pre-cancer detection. When a neoplasia occurs in tissue, morphologic and biochemical changes happen in the tissue, which in turn results in the change of optical properties and reflectance spectroscopy. Therefore, a pre-cancer can be detected by extracting optical properties from reflectance spectroscopy. This dissertation described the construction of a fiberoptic based reflectance system and the development of a series of modeling studies. This research is aimed at establishing an ...

2009-01-01

492

Water Quality and 401 Certification | Clean Water Act | US EPA  

Science.gov (United States)

Clean Water Act You are here: Water Laws & Regulations Policy & Guidance Clean Water Act Water Quality and 401 Certification Water Quality and 401 Certification Water Quality...

2011-08-28