WorldWideScience
 
 
1

Palo Verde control room human study: results  

International Nuclear Information System (INIS)

(1981). United States Guidetti, RP Luna, SF Rowland, JW Bechtel, Downey,

2

Palo Verde control room human factors study: methodology  

International Nuclear Information System (INIS)

(1981). United States Guidetti, RP Luna, SF Rowland, JW Bechtel, Downey,

3

Conditional risk assessment of SNR 300 in case of an unprotected loss of flow accident  

International Nuclear Information System (INIS)

This paper gives a summary of a risk study assuming unprotected loss of flow (ULOF) in the SNR 300. This study was initiated in 1979/80 by the Karlsruhe Nuclear Research Center and performed in close cooperation with Science Applications Inc., Palo Alto, USA, and Interatom Company. Part of the results also was integrated in the 'Risk Related Analysis for the SNR 300' carried out by the Gesellschaft fuer Reactorsicherheit. The character of the study described here is similar to other risk studies like the Reactor Safety Study and the German Risk Study for Nuclear Power Plants. The objectives and the methodology of the analyses are described and its results are discussed. (orig./RW).

4

Storing hydroelectricity to meet peak-hour demand  

Energy Technology Data Exchange (ETDEWEB)

This paper reports on pumped storage plants which have become an effective way for some utility companies that derive power from hydroelectric facilities to economically store baseload energy during off-peak hours for use during peak hourly demands. According to the Electric Power Research Institute (EPRI) in Palo Alto, Calif., 36 of these plants provide approximately 20 gigawatts, or about 3 percent of U.S. generating capacity. During peak-demand periods, utilities are often stretched beyond their capacity to provide power and must therefore purchase it from neighboring utilities. Building new baseload power plants, typically nuclear or coal-fired facilities that run 24 hours per day seven days a week, is expensive, about $1500 per kilowatt, according to Robert Schainker, program manager for energy storage at the EPRI. Schainker the that building peaking plants at $400 per kilowatt, which run a few hours a day on gas or oil fuel, is less costly than building ...

1992-04-01

5

Storing hydroelectricity to meet peak-hour demand  

International Nuclear Information System (INIS)

This paper reports on pumped storage plants which have become an effective way for some utility companies that derive power from hydroelectric facilities to economically store baseload energy during off-peak hours for use during peak hourly demands. According to the Electric Power Research Institute (EPRI) in Palo Alto, Calif., 36 of these plants provide approximately 20 gigawatts, or about 3 percent of U.S. generating capacity. During peak-demand periods, utilities are often stretched beyond their capacity to provide power and must therefore purchase it from neighboring utilities. Building new baseload power plants, typically nuclear or coal-fired facilities that run 24 hours per day seven days a week, is expensive, about $1500 per kilowatt, according to Robert Schainker, program manager for energy storage at the EPRI. Schainker the that building peaking plants at $400 per kilowatt, which run a few hours a day on gas or oil fuel, is less costly than building ...

1992-01-01

6

Adjoint sensitivity theory for steady-state ground-water flow  

Science.gov (United States)

In this study, adjoint sensitivity theory is developed for equations of two-dimensional steady-state flow in a confined aquifer. Both the primary flow equation and the adjoint sensitivity equation are solved using the Galerkin finite element method. The developed computer code is used to investigate the regional flow parameters of the Leadville Formation of the Paradox Basin in Utah and the Wolcamp carbonate/sandstone aquifer of the Palo Duro Basin in the Texas Panhandle. Two performance measures are evaluated, local heads and velocity in the vicinity of potential high-level nuclear waste repositories. The results illustrate the sensitivity of calculated local heads to the boundary conditions. Local velocity-related performance measures are more sensitive to hydraulic conductivities. The uncertainty in the performance measure is a function of the parameter sensitivity, parameter variance and the correlation between parameters. Given a parameter covariance matrix, ...

1983-11-01

7

Comparison of the argon tunable dye laser with the flashlamp pulsed dye laser in treatment of facial telangiectasia  

Science.gov (United States)

A prospective, side-by-side comparison study of two different lasers for the treatment of solar- induced telangiectasia was carried out in 14 patients at the Beckman Laser Institute and Medical Clinic. The argon tunable dye laser (Coherent, Palo Alto, Calif.) was used in the method modified from Orenstein and Nelson to completely treat discrete telangiectasias on one cheek. Specifically, the argon tunable dye laser (ATDL) was set at 0.7 - 0.8 watts, 585 nm wavelength, shutter-pulsed at 0.1 second duration with a spot size of 0.1 mm, and individual vessels were 'traced out' with 4X loupe magnification. Each patient's opposite cheek was then treated in the standard fashion with the flashlamp pulsed dye laser (Candela, Natick, Mass.) using a technique similar to Polla's et al. Specifically, the flashlamp pulsed dye laser (FPDL) was set at 585 nm wavelength, pulsed mode of 450 microseconds pulse duration, spot size of 5 mm, overlapping 10 - 20%, with power densities of ...

1992-06-01