The fission cross section of /SUP 242m/ Am has been measured from 0.005 eV to 20 MeV using time-of-flight techniques at the Oak Ridge Electron Linear Accelerator. A hemispherical plate fission ionizationchamber with five pairs of plates contained three deposits totaling 507 ..mu..g of /SUP 242m/ Am, one deposit of 168 ..mu..g /sup 235/U, and a ''weightless'' deposit of /sup 252/Cf, which served as a monitor of chamber performance. The fission of /sup 235/U, served as the cross-section standard for energies above 101 keV while /sup 6/Li(n,..cap alpha..), normalized to /sup 235/U fission in the 7.8- to 11.0-eV interval, served as a shape standard below 101 keV. Approximately 360 h of data were obtained at a flight path distance of 9.1 m, primarily with 40-ns bursts. Particular attention was paid to correction of backgrounds, especially inscattered-neutron-induced ...
The fission cross section of /SUP 242m/ Am has been measured from 0.005 eV to 20 MeV using time-of-flight techniques at the Oak Ridge Electron Linear Accelerator. A hemispherical plate fission ionizationchamber with five pairs of plates contained three deposits totaling 507 #mu#g of /SUP 242m/ Am, one deposit of 168 #mu#g "2"3"5U, and a ''weightless'' deposit of "2"5"2Cf, which served as a monitor of chamber performance. The fission of "2"3"5U, served as the cross-section standard for energies above 101 keV while "6Li(n,#alpha#), normalized to "2"3"5U fission in the 7.8- to 11.0-eV interval, served as a shape standard below 101 keV. Approximately 360 h of data were obtained at a flight path distance of 9.1 m, primarily with 40-ns bursts. Particular attention was paid to correction of backgrounds, especially inscattered-neutron-induced events. The fission resonance integral was found to be 1800 + or - ...
A new type of ionizationchamber with levitated electrode has been developed. In this ionizationchamber, an ion-collection electrode levitates in the air without getting any physical support from the insulator. The electrode is charged by an electrostatic charger without physical contact. The charge of the electrode is read out at a Faraday cage periodically at a given time interval without physical contact. Because its electrode levitates, the ionizationchamber produces no background current caused by leaks or piezo current. In addition, as the charging of its electrode and the read-out of its charge are carried out without physical contact, no irregular charge or contact potential difference due to the chattering between electrode and contact point occurs. Through experiments, it was found that this ionization ...
A custom-built graphite-coated transmission ionizationchamber is compared to the VacuDAP 2001 (VacuTec, Dresden, Germany), which has transparent conductive electrodes. A study was made of the dependence of response on x-ray tube potential for both types of chamber under identical conditions of exposure using over-table and under-table x-ray tubes. Since the calibration factor is the dose-area product of the radiation incident on the patient per chamber reading, it depends on the intrinsic response of the chamber as well as the effect of material in the beam between the x-ray tube and patient. Differences of about 20% were measured between the intrinsic and the over-table calibration factors and between the over-table and the under-table calibration factors for both chambers. The VacuDAP display is specifically calibrated for the over-table condition and would ...
The /sup 252/Cf-source-driven neutron noise analysis method for obtaining the subcriticality of an assembly of fissile material from cross-power spectral densities (CPSDs) was developed to avoid some difficulties inherent in other measurement methods. This method requires measurement of frequency-dependent CPSD between a pair of detectors in or near the fissile assembly and CPSDs between these detectors and a source of correlated neutron noise from an ionizationchamber containing /sup 252/Cf, also in or near the fissile assembly. Also, the auto-power spectral density of the source is required. The ratio of spectral densities is then formed and is related to the subcriticality. To date various measurements have been performed which demonstrate the usefulness of the method including measurements with single uranium metal cylinders. The experiments described here, which used coupled uranium (93.15 wt % /sup 235/U) metal ...
An ionizationchamber with fast timing properties was built at CERN for measuring fission cross-sections of minor actinides at the n(_)TOF neutron beam. The design of this new chamber and of the front-end electronics was optimized to match the innovative features of the n(_)TOF facility, in particular the high instantaneous neutron flux and low background. For the most radioactive isotopes, a special version of the chamber, designed according to the ISO2919 standards, was built in order to comply with the radioprotection requirements at CERN. The detector and front-end electronics are here described, together with the simulated and measured response to fission fragments and #alpha#-particles. The performances of the chamber during the first measurement campaign at n(_)TOF are presented, focusing in particular on the fast time response, the good background rejection capability, ...
A new method named 'Bragg curve spectroscopy', based on the Bragg curve of the heavy ion being stopped in a gaseous ionizationchamber, has been developed for identifying the particle and measuring its energy. The design of such a chamber and the experience obtained with chamber using various kinds of fast heavy ions are described. In conclusion, several problems to be solved in this method are pointed out.
A new method named 'Bragg curve spectroscopy', based on the Bragg curve of the heavy ion being stopped in a gaseous ionizationchamber, has been developed for identifying the particle and measuring its energy. The design of such a chamber and the experience obtained with chamber using various kinds of fast heavy ions are described. In conclusion, several problems to be solved in this method are pointed out. (orig.).
The Bragg Curve Spectrometer (BCS) is an ionizationchamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. We have constructed and tested several versions of the BCS. The results are described.
The Bragg Curve Spectrometer (BCS) is an ionizationchamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. We have constructed and tested several versions of the BCS. The results are described.
In an ionizationchamber with the electric field parallel to the particle trajectories, the time dependence of the anode signal contains all the information about the energy and the nuclear charge of the ionizing particle. By proper pulse shaping with a long and a short time constant the total ionization charge and the ionization charge integrated around the Bragg maximum, respectively, can be obtained. The former signal is proportional to the total energy, whereas the latter allows the nuclear charge to be deduced directly. An energy resolution of 0.4% and a Z resolution ..delta..Z/Z = 1/82 was achieved for 130 MeV /sup 32/S ions and argon-methane as the stopping medium.
The development of a new configuration of chemical ionization (CI)-based ion source is presented. The ambient air containing the gaseous sample is sniffed into an enclosed ionizationchamber which is of sub-ambient pressure, and is subsequently mixed with metastable species in front of the ion inlet of the mass spectrometer. Metastable helium atoms (He*) are used in this study as the primary ionizing agents and are generated from a dielectric barrier discharge (DBD) source. The DBD is powered by an AC high-voltage supply and the configuration of the electrodes is in such a way that the generated plasma is confined within the discharge tube and is not extended into the ionizationchamber. The construction of the ion source is simple, and volatile compounds released from the bulky sample can...
When exposure-calibrated ionizationchambers are used to calibrate megavoltage X-ray and electron beam therapy machines, the calibration factor can be divided into a chamber-dependent and a chamber-independent component. Until recently, only the chamber-independent part, which has been derived theoretically, has been used; the chamber-dependent component has been ignored. Recent experimental and theoretical considerations, however, have indicated that the dependent component must be taken into account and can affect the calibration by as much as 4%. The calibration can change due to (i) the thickness of the chamber wall, (ii) the chamber wall composition, i.e. whether the chamber is constructed of air-equivalent material, or tissue- or water-equivalent material, and (iii) the size of the ...
A novel approach to the Bragg curve spectroscopy is utilized to construct a charged particle detector which makes fragment elemental identification and energy measurement possible. The advantage of the construction includes good timing and spectroscopic properties with a very low energy threshold. ((orig.))
An unexpectedly high probability of collisions between the fission particles and the atoms in an ionizationchamber along the entire particle track causes a strong fluctuation of the shapes of the Bragg curves. This fluctuation imposes an upper limit of the charge resolution ..delta..Z/Z which can be achieved.
A detector head for in situ inspection of irradiated nuclear fuel assemblies submerged in a water-filled nuclear fuel storage pond. The detector head includes two parallel arms which extend from a housing and which are spaced apart so as to be positionable on opposite sides of a submerged fuel assembly. Each arm includes an ionizationchamber and two fission chambers. One fission chamber in each arm is enclosed in a cadmium shield and the other fission chamber is unshielded. The ratio of the outputs of the shielded and unshielded fission chambers is used to determine the boron content of the pond water. Correcting for the boron content, the neutron flux and gamma ray intensity are then used to verify the declared exposure, cooling time and fissile material content of the irradiated fuel assembly.
The Bragg Curve Spectrometer (BCS) is an ionizationchamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is proportional to the specific ionization along the track. The preamp output is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. Several versions of the BCS have been constructed and tested. Test results, detector characteristics and some design problems are discussed.
There are two types of ionizationchamber using magnetically levitated electrode: one is that by Tanaka et al. and the other, by authors'. The latter lacks the sensitivity relative to the former and thereby to solve the problem, authors made an improvement so that the electrode charge could be readout by noncontact after the leviated electrode was electrified by noncontact for an interval. This new type ionizationchamber made it possible to measure the quite low dose radiation with stability and high sensitivity. Actually, the electrode was suspended by the teflon thread fixed on the steel cup levitated magnetically in the ionizationchamber of which wall was covered by Al and equipped with an electrostatic charger for the electrode by noncontact. After measurement, the electrode was moved in the Faraday cage placed under the ...
A patent is claimed for the invention of a hardening (ionizing radiation resistance) process for MOS type components and CMOS or bipolar type components. The ionizing radiation effect on those systems is the electron-hole pair production, which induces interference phenomena. The MOS main structure is successively composed of a silicon substrate layer, a layer of an irradiation resistant material and a layer of partially monocrystalline silicon.
An alternative utilization is presented for the gaseous ionizationchamber in the detection of energetic heavy ions, which is called Bragg Curve Spectroscopy (BCS). Conceptually, BCS involves using the maximum data available from the Bragg curve of the stopping heavy ion (HI) for purposes of identifying the particle and measuring its energy. A detector has been designed that measures the Bragg curve with high precision. From the Bragg curve the range from the length of the track, the total energy from the integral of the specific ionization over the track, the dE/dx from the specific ionization at the beginning of the track, and the Bragg peak from the maximum of the specific ionization of the HI are determined. This last signal measures the atomic number, Z, of the HI unambiguously.
A complete heavy ion identification system in heavy ion reaction studies consists, in general, of: 1) a position sensitive avalanche counter, and 2) ionizationchamber to obtain total energy as well as a heavy ion identifier signal (such as the E#DELTA#E signal from a E-#DELTA#E type detector or the height of the Bragg peak that scales as Z of the heavy ion in a Bragg curve ionizationchamber). In addition, a time-of-flight information may be needed to resolve the masses of the ions. With this motivation in mind, a composite detector system consisting of a Bragg curve spectroscopy ionizationchamber (BCS-IC) and a one dimensional position sensitive parallel grid avalanche counter (XPS-PGAC) has been developed and used successfully at the BARC-TIFR pelletron accelerator facility. The design and performance of this gas detector system are reported. (author). 4 ...
The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionizationchambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionizationchambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration certificate and data sheets are presented. (author)
The Bragg-curve detector of the parallel plate ionizationchamber type generates a signal that is a distorted replica of the original Bragg-curve. In result of this distortion, the signal peak height is not only a function of the atomic number of the heavy ion, as it is often stated, but also of the particle mass. This mass effect was studied with the aid of computer simulation, and it was found to be dependent on the Frisch grid to anode gap width and on the detector gas. The charge resolution of the detector is affected very significantly by this mass dependence of the signal peak height. Therefore, a careful selection of the detector gas and the grid to anode gap width is necessary, if good charge resolution over a wide range of heavy ions is required. (orig.).
The Bragg-curve detector of the parallel plate ionizationchamber type generates a signal that is a distorted replica of the original Bragg-curve. In result of this distortion, the signal peak height is not only a function of the atomic number of the heavy ion, as it is often stated, but also of the particle mass. This mass effect was studied with the aid of computer simulation, and it was found to be dependent on the Frisch grid to anode gap width and on the detector gas. The charge resolution of the detector is affected very significantly by this mass dependence of the signal peak height. Therefore, a careful selection of the detector gas and the grid to anode gap width is necessary, if good charge resolution over a wide range of heavy ions is required.
A focal plane detector system consisting of a vertical drift chamber, parallel plate avalanche counters, and an ionizationchamber with segmented anodes has been installed in the Broad Range Spectrometer at the Holifield Facility at Oak Ridge. The system, which has been designed for use with light-heavy ions with energies ranging from 10 to 25 MeV/amu, has a position resolution of approx. 0.1 mm, a scattering angle resolution of approx. 3 mrad, and a mass resolution of approx. 1/60.
In the beam pipe of the positron damping ring of the Next Linear Collider, electrons will be created by beam interaction with the surrounding vacuum chamber wall and give rise to an electron cloud. Several solutions are possible for avoiding the electron cloud, without changing the bunch structure or the diameter of the vacuum chamber. Some of the currently available solutions for preventing this spurious electron load include reducing residual gas ionization by the beam, minimizing beam photon-induced electron production, and lowering the secondary electron yield (SEY) of the chamber wall. We will report on recent SEY measurements performed at SLAC on TiN coatings and TiZrV non-evaporable getter thin films.
A new method of particle identification of heavy ions through the measurement of the Bragg curve centroid and particle energy has been developed using a gas ionizationchamber with a resistive anode layer. Z-resolutions comparable to the conventional ..delta..E-E counter telescope could be rather easily attained.
A new method of particle identification of heavy ions through the measurement of the Bragg curve centroid and particle energy has been developed using a gas ionizationchamber with a resistive anode layer. Z-resolutions comparable to the conventional #DELTA#E-E counter telescope could be rather easily attained. (orig.).
A new article identification method based on the measurement of Bragg-curve centroids using a gas-filled ionizationchamber has been improved for detection of low-energy particles around 1 MeV per nucleon by introducing a nonuniform distribution of resistance on the anode electrode. Almost the same quality of Z-resolutions as in the conventional ..delta..E-E method could be obtained up to Z=19.
Projectilelike fragments following the 80 MeV /sup 16/O+/sup 27/Al reaction have been detected using a Bragg-curve spectroscopy ionizationchamber (BCS-IC). The atomic number is deduced from the Bragg-peak amplitude. Nitrogen isotopes are clearly resolved using either range or energy loss data. This is the first application of the BCS method for complete ion identification in a heavy-ion-induced reaction.
Projectilelike fragments following the 80 MeV "1"6O+"2"7Al reaction have been detected using a Bragg-curve spectroscopy ionizationchamber (BCS-IC). The atomic number is deduced from the Bragg-peak amplitude. Nitrogen isotopes are clearly resolved using either range or energy loss data. This is the first application of the BCS method for complete ion identification in a heavy-ion-induced reaction.
The performance of a Bragg ionizationchamber has been investigated as a function of the counting rate with approx.= 5 MeV/amu /sup 32/S beams: up to approx.= 20 kHz the energy resolution is below 0.9% and the Z resolving power is more than 50. (orig.).
In this work dosimetric analysis using thermoluminescence technique to study the beams characteristics of x-rays employed in dental radiology has been carried out. The obtained results with CaSO{sub 4}:Dy thermoluminescent dosimeters (TLD) were compared to the doses obtained with parallel-plates ionizationchamber. Dosimetric evaluations were also done using radiographic films of large dimensions. The x-rays equipments analyzed were installed in the radiological services of Odontology Department of Sergipe Federal University (U.F.S.). Depending on the anatomical region to be examined the proper exposure time was select, for a fix voltage of 70 kV. The results with TLD and ionizationchamber have been determined to female and male individuals. The intraoral regions analysed were the peri apical of the incisors, molar and pre-molar teeth and the occlusive region. These regions were simulated using acrylic ...
The part of the FFTF Reactor Characterization Program reported in this paper is a measurement of absolute fission rates of eight major fuel isotopes at two different positions within the reactor. The instruments employed in these tests were fission ionizationchambers for which the absolute efficiency and fissionable deposit mass assay have been rigorously established.
In everyday radiotherapy we must carry out the determination of absorbed dose measurement according to JARP's protocol. We explained an outline of JARP's 1974 and 1986 protocol in electron beam therapy, and mentioned it about the matter that should examined. To use it easily in clinic, a simplified procedure based on precisely to JARP's 1986 protocol is practical, the character of this procedure settles briefly the determination of mean incident energy of electron beams and get ready to table of ionization to absorbed dose conversion factor for various ionizationchamber. Also, this procedure almost not influence on the accuracy of determination. We described systematically practical procedure for requisite absorbed dose calculation in a patient in electron beam therapy. (author).
A heavy ion gas detector system consisting of a Bragg-curve spectroscopy ionizationchamber for particle identification and a multiwire proportional chamber as position sensitive fast trigger device is described. The Bragg IC has been tested with several beams up to Z=36 to investigate some aspects of the BCS method. Results are reported on energy resolution and linearity, Z resolving power and mass sensitivity. The energy resolution is well below 1%. The Bragg-peak amplitude is fairly independent of the energy in a wide energy range and single elements are identified up to Z=38 with a resolving power Z/..delta..Zproportional50-80. Isotope identification by range measurement is limited by the straggling in the ionization process and the mass resolving power is M/..delta..Mproportional20-26 for S and Si isotopes. The MWPC allows subnanosecond time resolution and position identification along the in-plane ...
A heavy ion gas detector system consisting of a Bragg-curve spectroscopy ionizationchamber for particle identification and a multiwire proportional chamber as position sensitive fast trigger device is described. The Bragg IC has been tested with several beams up to Z=36 to investigate some aspects of the BCS method. Results are reported on energy resolution and linearity, Z resolving power and mass sensitivity. The energy resolution is well below 1%. The Bragg-peak amplitude is fairly independent of the energy in a wide energy range and single elements are identified up to Z=38 with a resolving power Z/#DELTA#Zproportional50-80. Isotope identification by range measurement is limited by the straggling in the ionization process and the mass resolving power is M/#DELTA#Mproportional20-26 for S and Si isotopes. The MWPC allows subnanosecond time resolution and position identification along the in-plane ...
Because the number of neutrons and gamma rays and the energy spectrum of particles from spontaneous fission are well characterized for {sup 252}Cf, it can be used as a timed source of fission neutrons and gamma rays. The first such usage incorporated a {sup 252}Cf source into gas scintillators. This paper describes a timed source of neutrons and gamma rays made by depositing {sup 252}Cf on one electrode of a parallel plate ionizationchamber that can then be used for determining detection-system characteristics. The emission time of neutrons from spontaneous fission has also been determined by recording the emission time of prompt gamma rays from a {sup 252}Cf source (not incorporated into a detector) adjacent to the surface of a solid or liquid scintillator. This well characterized source of neutrons can thus be used as a randomly pulsed source for a variety of applications. This paper illustrates the use of this type of source to determine ...
This digest paper presents the theoretical project of a fission engine for space ship as imagined by Y. Ronen from the Ben-Gourion Univ. (Israel). In this engine, the combustion chamber is covered with metastable {sup 242}Am thin sheets. The fission reaction is triggered with a bombardment of neutrons and the fission fragments ionize a gas (hydrogen, for instance) which is overheated and ejected through the engine nozzle. (J.S.)
Energy and angular double-differential cross-section (DDX) data of fragment production reactions by neutrons or protons are very scarce due to experimental difficulties of fragment detection. We adopted a Bragg curve spectrometer (BCS), which is a gridded-ionizationchamber that can identify fragments on the basis of the Bragg peak value. We have been developing the BCS for neutron and proton-induced reactions applying the digital waveform analysis technique to obtain better ability of particle discrimination than the analog electronic circuit. (T. Tanaka)
A multiple sampling dE/dx counter using a multiwire proportional chamber equipped with catbode pads was constructed for the multiple detection of dE/dx values along a particle trajectory. For low-energy particles this counter was proved to be useful as a Bragg-curve detector. At relativistic energies around E=14.6 GeV/nucleon good particle identification was obtained by cathode pad signals as well as anode signals for the range of projectile fragments from Z=1 (minimum ionization) up to a beam charge of Z=14. (orig.).
A new method, near-infrared laser desorption/ionization aerosol mass spectrometry (NIR-LDI-AMS), is described for the real time analysis of organic aerosols at atmospherically relevant mass loadings. Use of a single NIR laser pulse to vaporize and ionize particle components deposited on an aluminum probe results in minimal fragmentation to produce exclusively intact pseudomolecular anions at [M-H](-). Limits of detection (total particulate mass sampled) for oxidized compounds of relevance to atmospheric primary and secondary organic aerosol range from 89 fg for pinic acid to 8.8 pg for cholesterol. NIR-LDI-AMS was used in conjunction with the University of Vermont Environmental Chamber to study secondary organic aerosol (SOA) formation from ozonolysis of limonene at total aerosol mass loadings ranging from 3.2 to 25.0 ?g m(-3) and with a time resolution of several minutes. NIR-LDI-AMS permitted direct delineation between ...
Long-Range Alpha Detector (LRAD) systems are designed to monitor alpha contamination by measuring the number of ions in the air. Alpha particles are a form of ionizing radiation and a typical 5-MeV alpha particle will create about 150,000 ion pairs in air. Field tests at various DOE sites have shown that LRAD Surface Soil Monitors (SSM), Sample Monitors, and Object Monitors are faster and more sensitive than traditional alpha detectors for measuring alpha contamination. This paper discusses the various applications of LRAD technology to low-level radioactive waste management.
Energy and angular double differential cross-section data of fragments by tens of MeV neutron or proton are important to evaluate dosimetry and radiation effect in devices or instruments, since fragments cause a large local ionization. Up to now, experimental data of the fragment production are very scarce due to experimental difficulties of fragment detection. A bragg curve spectrometer (BCS) for fragment measurement is a gridded-ionizationchamber that identify fragments on the basis of the difference of Bragg peak value. The BCS was fabricated to adopt for fragment measurement in neutron-induced reactions and tested with a charged-particle beam and then applied to a neutron field successfully. The structure of BCS is a cylindrical gridded ionizationchamber, and filled with a Ar + 10% CH{sub 4} gas at a pressure of 2.7 x 10{sup 4} Pa. To confirm the performance of BCS, the ...
A significant amount of X-rays were detected as a leakage from some of the Crooke`s tubes which were used in the teaching of science at junior and senior high schools in Japan. We measured the leaked dose of X-rays from the Crooke`s tubes with ionizingchambers, film badges and TLDs. The maximum leaked dose at 5cm distance from those tubes was estimated 143mSv/h. The effective energy of leaked X-rays was 19.3keV. The maximum dose of students exposed during the teaching of science were estimated 0.15mSv per experiment, which exceeded the value recommended in the ICRP publication 36. (author)
We describe calculations of the energy loss, range, stopping power, multiple scattering, and other related properties of a high-energy heavy-ion beam at any one of a set of beam line elements. A beam line element (e.g., any beam modification, detection, or control device) is characterized by its thickness, areal density, aperture, and function. The loss of multiply scattered particles to any finite-aperture detector is calculated in the small-angle approximation, and the position of the Bragg peak, as given by particles stopping in the second of two ionizationchambers used for Bragg curve measurements, is estimated. A general purpose computer program, PROPAGATE, has been written to allow addition, deletion, and modification of the beam line elements used in the calculation and to provide a convenient means of repeating such calculations for arbitrary beam lines. Calculations and experimental measurements are compared and found to be in ...
This report describes all time and frequency analysis parameters measured with the new Nuclear Weapons Identification System (NWIS) processor with three input channels: (1) the {sup 252}Cf source ionizationchamber; (2) a detection channel; and (3) a second detection channel for active measurements. An intuitive and physical description of the various functions is given as well as a brief mathematical description and a brief description of how the data are acquired. If the full five channel capability is used, the number of functions increases in number but not in type. The parameters provided by this new NWIS processor can be divided into two general classes: time analysis signatures including multiplicities and frequency analysis signatures. Data from measurements with an 18.75 kg highly enriched uranium (93.2 wt%, {sup 235}U) metal casting for storage are presented to illustrate the various time and frequency analysis parameters.
This report describes all time and frequency analysis parameters measured with the new Nuclear Weapons Identification System (NWIS) processor with three input channels: (1) the 252Cf source ionizationchamber (2) a detection channel; and (3) a second detection channel for active measurements. An intuitive and physical description of the various functions is given as well as a brief mathematical description and a brief description of how the data are acquired. If the fill five channel capability is used, the number of functions increases in number but not in type. The parameters provided by this new NWIS processor can be divided into two general classes: time analysis signatures including multiplicities and frequency analysis signatures. Data from measurements with an 18.75 kg highly enriched uranium (93.2 wt 0/0, 235U) metai casting for storage are presented to illustrate the various time and frequency analysis parameters.
By using Bragg curve spectroscopy, one can measure atomic number and energy of high energy heavy ions stopping in a gas-filled ionizationchamber with longitudinal electric field. In this paper, we report on the results obtained with an isobutane filled detector. An energy resolution of 0.8% fwhm and a Z resolution of 2.7% fwhm were achieved for elastically scattered 300 MeV /sup 40/Ar ions. We study the Bragg peak amplitude dependence on the energy of the incoming ions, a dependence presumably due to the Frisch grid screening inefficiency. The corrected Bragg peak spectrum of inelastically scattered 300 MeV /sup 40/Ar ions exhibits a satisfactory Z separation around Z = 18.
By using Bragg curve spectroscopy, one can measure atomic number and energy of high energy heavy ions stopping in a gas-filled ionizationchamber with longitudinal electric field. In this paper, we report on the results obtained with an isobutane filled detector. An energy resolution of 0.8% fwhm and a Z resolution of 2.7% fwhm were achieved for elastically scattered 300 MeV "4"0Ar ions. We study the Bragg peak amplitude dependence on the energy of the incoming ions, a dependence presumably due to the Frisch grid screening inefficiency. The corrected Bragg peak spectrum of inelastically scattered 300 MeV "4"0Ar ions exhibits a satisfactory Z separation around Z = 18. (orig.).
A time-of-flight (TOF) spectrometer has been constructed at the JAERI 20 MV tandem accelerator facility. A position-sensitive start detector, which consists of a thin carbon foil, microchannel plates and a resistive plate, was developed for the TOF measurements through the spectrometer. The time and position resolutions obtained were 120 ps and 0.3 mm for ..cap alpha.. particles from /sup 241/Am, respectively. A two-dimensional position-sensitive detector was also developed to measure the solid angle of the spectrometer and the maximum solid angle obtained was 9.5 msr. As a particle detector a Bragg curve ionizationchamber was developed. From the Bragg curves of heavy ions in the detector, energies, ranges and Bragg curve peaks were measured and used for particle identification. The resolving power Z/..delta..Z of the atomic number was about 50.
The neutron-induced fission cross-section of {sup 233}U has been measured at the CERN n-TOF facility relative to the standard fission cross-section of {sup 235}U between 0.5 and 20MeV. The experiment was performed with a fast ionizationchamber for the detection of the fission fragments and to discriminate against {alpha} -particles from the natural radioactivity of the samples. The high instantaneous flux and the low background of the n-TOF facility result in data with uncertainties of {approx} 3%, which were found in good agreement with previous experiments. The high quality of the present results allows to improve the evaluation of the {sup 233}U (n,f) cross-section and, consequently, the design of energy systems based on the Th/U cycle. (orig.)
Relative doses of 75 MeV/u "1"2C ion beam after passing through different thickness of degraders were measured with the double ionizationchamber method. The degrader's thickness equalized to penetration depth of the beam in water and its Bragg curve were obtained. The measured Bragg curve is compared with that calculated based on a model set up by the authors. Meanwhile, the inactivation effect of the ion beam passing through different thickness of degraders on melanoma (B_1_6) cells was measured, and the corresponding survival fraction data for B_1_6 cells were acquired
Summaries are included of research contracts which expired prior to Dec. 31, 1960. The contracts were concerned with investigations of: electrophysiological responses of biological systems in nerve cells to irradiation with small doses of ionizing radiations; the mode of the protective action of certain sulfhydryl compounds against radiation effects on the synthesis of deoxyribonucleic acid, using tritium-labeled thymidine; development of a bubble chamber method of monitoring and dosimetry for Low fast neutron fluxes; effects of incorporated radioisotopes on the stability of genetic materials; interrelation of root and leaf absorption of radioisotopes in herbaceous plants; uptake of radioactive wastes by lowland rice from soils contaminated by irrigation water, and decontamination of the rice; and comparison between mutation rates induced by acute and chronic gamma irradiations. (B.O.G.)
It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionizationchamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.
Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle3 treatment planning system, and the dose was calculated in a water phantom. Ionizationchamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as w...
The /sup 252/Cf-source-driven noise analysis method determines the subcriticality of a system containing fissionable material from the ratio of cross power spectral densities between the detectors that detect particles from the fission process and between these detectors and an ionizationchamber containing a spontaneously fissioning neutron source which provides neutrons to induce fission in the system. This method has two advantages: (1) a calibration is not required and thus subcriticality can be determined from measurements only on the subcritical system of interest, and (2) the subcriticality is independent of the type of detector or its efficiency. These properties of this technique are illustrated by measurements.
The widespread use of building materials with relatively high radium concentrations may increase population exposure. A method is presented for measuring effective diffusion coefficients and exhalation rates of radon from such materials. Equations for use in the experimental determination of these values are obtained theoretically. The experimental set-up consists of a container which is hermetically sealed to a slab of the building material. Nitrogen is blown through the container and then through an ionizationchamber which is connected to an electrometer and X-Y plotter, and the radon concentration is measured continuously. Exhalation rates of radon from some major building materials measured by this method will be used as reference levels. The method can also be used to determine other properties such as porosity. (author).
The goal of this DOE-supported exhibition is to demystify Einstein`s formula E = mc{sup 2} by illustrating the interchangeability of matter (m) and energy (E), c{sup 2} being the exchange rate. The exhibition has two major parts, {open_quotes}matter into energy{close_quotes} and {open_quotes}energy into matter{close_quotes}, plus a video to connect them. {open_quotes}Matter into energy{close_quotes} has now been completed and has been placed on the museum floor. Positrons from a {sup 22}Na source are annihilated to produce gamma rays that are caught in NaI detectors. The viewer can alter the alignment of the detectors and observe the consequences for the rates of single and coincident counts. The viewer can also observe the effects of placing absorbers in front of the counters. Prototype explanatory graphics were placed around the exhibit and those will probably be changed after we have some experience with their effectiveness. The connecting video is in the process of being produced ...
The Muon Ionization Cooling Experiment (MICE) focusing solenoid magnets focus the muon beam within the MICE cooling channel on a liquid or solid absorber that is within the warm bore of solenoid. The focusing magnet has a warm bore of 470 mm. his magnet consists of two coils 210-mm long that is separated by an aluminum mandrel that is 200 mm long. Each of the coils has its own leads. The coils may be operated in either the non-flip mode (solenoid mode with both coils at the same polarity) or the lip mode (quadrupole focusing mode where both coils are at opposite polarity). This report describes the focusing solenoid magnet design that will be built by the vendor. The progress on the construction of the first of the focusing magnets will also be discussed in this report. Ultimately three of these magnets will be built. These magnets will be cooled using a pair 1.5 W (at 4.2 K) pulse tube coolers.
Full text of publication follows: Slightly over-stoichiometric lithium orthosilicate pebbles have been selected as one optional breeder material for the European Helium Cooled Pebble Bed (HCPB) blanket. This material has been developed in collaboration of Research Center Karlsruhe and the Schott Glass, Mainz. The lithium orthosilicate pebbles are fabricated from lithium hydroxide and silica by a melting and spraying method in a semi-industrial scale facility. Lithium hydroxide was selected as the precursor since enriched lithium hydroxide is commercially available. The lithium orthosilicate pebbles produced by the process contains oxide phases besides orthosilicate, but it was also found that the oxide phases can be decomposed by annealing at high temperatures. The lithium orthosilicate pebbles produced in this way possesses satisfactory pebble characteristics. Therefore, the authors performed out-of-pile annealing tests using the lithium orthosilicate pebbles irradiated in a research ...
The purpose of this study is to evaluate the accuracy of dose calculations by three algorithms. Depth dose, OPF (Output Factor) and dose profiles were measured in a heterogeneous phantom. These values were also calculated by three algorithms of the Batho power law (BPL), Equivalent-Tissue Air Ratio (ETAR) and Convolution superposition (CS). The data were obtained for 4, 6 and 10 MV photon beams with a linear accelerator (Varian 21EX). Field size ranged from 3 x 3 cm"2 to 10 x 10 cm"2. Dose profiles of beam penumbra were also measured by a 0.125 ml ionizationchamber at the point of 8, 13 and 18 cm from the surface of the phantom at intervals of 1 mm. Differences between measured and calculated depth doses were within 2% in BPL and CS, but depth doses were overestimated in ETAR. OPFs were also overestimated with the error of more than 4% in ETAR. Absorbed dose calculated by CS were in agreement with the values measured by the ...
The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma distribution was compared to the dose distribution measured by an ionizationchamber at three different ...
Experience with multiwire proportional chambers at high rates at the Argonne Zero Gradient Synchrotron is described. A buildup of silicon on the sense wires was observed where the beam passed through the chamber. Analysis of the chamber gas indicated that the density of silicon was probably less than 10 ppM.
Experience with multiwire proportional chambers at high rates at the Argonne Zero Gradient Synchrotron is described. A buildup of silicon on the sense wires was observed where the beam passed through the chamber. Analysis of the chamber gas indicated that the density of silicon was probably less than 10 ppM.
As part of a U.S. multi-regional pilot study conducted by the six Centers for Radiological Physics, 12-mm-diameter by 0.4-mm-thick CaSO/sub 4/:Dy Teflon-embedded discs were evaluated and used to measure patient entrance exposure on 60 average patients at 12 clinical centers. The discs were found to have adequate sensitivity, reproducibility and linearity up to 69.7 microC kg-1 (270 mR). The minimum measurable exposure was estimated as 0.4 microC kg-1 (1.5 mR). All responses were corrected for energy dependence, which varied +/- 20% from 1.7 to 6.5 mm Al half-value layer. Patient entrance exposure values ranged from 1.3 to 28 microC kg-1 (5 to 110 mR), with a median value of 5.2 microC kg-1 (20 mR). This value agreed with exposure measurements made on the chest radiography equipment using an ionizationchamber and a phantom which simulated an average patient, and with published Nationwide Evaluation of X-Ray Trends (NEXT) data for the same ...
The DITE (Divertor Injection Tokamak Experiment) program has been undertaken to demonstrate the feasibility of impurity control by the use of a diverter in an injection-heated toroidal plasma configuration. Rather than behaving in accordance with neoclassical toroidal containment theory, the plasma is subject to various instabilities, particularly the resistive fluid MHD types, follows the empirical scaling of energy confinement time with plasma parameters observed in other plasma devices. DITE experiments have, however, extended the range of current and density. Impurities arising from plasma interactions with the vacuum vessel surface are controlled by the bundle divertor, which diverts a portion of plasma and power in the plasma scrape-off layer into a separate target chamber where impurities can be removed. Auxiliary plasma heating is provided by the injection of powerful beams of neutral hydrogen atoms produced by multi-aperture ion sources and hydrogen gas ...
This paper describes recent measurements of the subcritical neutron multiplication factor using the /sup 252/Cf source-driven neutron noise analysis method. This work was supported by a program of collaboration between the United States Department of Energy and the Power Reactor and Nuclear Fuel Development Corporation of Japan related to the development of fast breeder technology. The experiment reported consists of a configuration of two interacting tanks of uranyl nitrate aqueous solution with different uranium concentrations in each tank. The /sup 252/Cf-source-driven neutron noise analysis method obtains the subcriticality from the signals of three detectors: the first, a parallel plate ionizationchamber with /sup 252/Cf electroplated on one of its plates that is located in or near the system containing the fissile material, and produces an electrical pulse for every spontaneous fission that occurs and thereby serves as a timed source of ...
High pressure xenon ionizationchamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics was used to characterize the pulse rise time of deposited gamma ...
A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionizationchamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL sheet was suggested to provide a convenient means of measuring the dose distribution around {sup 60}Co ...
The "2"3"3U(n, f) cross-section has been measured at n_TOF in a wide energy range with a dedicated fission ionizationchamber. We report here the results from 0.30 meV to 1 MeV neutron energy. The "2"3"3U(n, f) cross-section has been determined relative to a reference sample of "2"3"5U(n, f) measured simultaneously with the same detector. The very high instantaneous neutron flux and the intrinsically low background of the n TOF installation result in an accuracy around 3% in the whole energy range, while the energy resolution of the neutron beam allows for an accurate description of the fission cross-section by means of R-matrix analysis over a wide energy range. The present data provide the basis for a more precise evaluation of the "2"3"3U fission cross-section, and for improving the reliability of databases needed for the design of new energy systems based on the Th/U cycle. (Author)
The BEATRIX-II irradiation experiment is an in-situ tritium release experiment being carried out in the Fast Flux Test Facility (FFTF) reactor to evaluate the tritium release characteristics of fusion solid breeder materials. A sophisticated tritium gas handling system has been developed to continuously monitor the tritium recovery from the specimens and facilitate tritium removal from the experiment's sweep gas flow stream. The in-situ recovery experiment accommodates two different in-reactor specimen canisters with individual gas streams and temperature monitoring/control. Ionizationchambers have been specifically designed to respond to the rapid changes in the tritium release rate at the anticipated tritium concentrations. Two ceramic electrolysis cells have proved effective in reducing the moisture in the gas streams to hydrogen/tritium. A tritium getter system, capable of reducing the tritium level by a factor greater than 4000, ...
A computerized system for monitoring dose-area product (DAP) has been developed for region of interest (ROI) fluoroscopy in which patient exposure is reduced using an x-ray attenuating filter with an aperture. The system includes an IBM compatible computer which is connected through an IEEE-488 interface to an electrometer which measures the charge from a DAP ionizationchamber. A digital input/output board connects the computer to the filter placement device to determine whether the filter is in or out of the beam, and to the x-ray generator to determine when the exposure is due to spot filming. The computer logs the DAP from conventional fluoroscopy, ROI fluoroscopy and spot filming separately, applying the appropriate calibration factor for each. Measured DAPs, fluoroscopic DAP rates and exposure times are displayed in real-time. The system has been installed in a GI fluoroscopic room so that the dose-reduction potential of ROI imaging can ...
The aim of this work was to study acute alterations of the enterohepatic recirculation (EHR) of bile acids 3 days after an 8-Gy radiation exposure in vivo in the rat by a washout technique. Using this technique in association with HPLC analysis, the EHR of the major individual bile acids was determined in control and irradiated animals. Ex vivo ileal taurocholate absorption was also studied in Ussing chambers. Major hepatic enzyme activities involved in bile acid synthesis were also measured. Measurements of bile acid intestinal content and intestinal absorption efficiency calculation from washout showed reduced intestinal absorption with significant differences from one bile acid to another: absorption of taurocholate and tauromuricholate was decreased, whereas absorption of the more hydrophobic taurochenodeoxycholate was increased, suggesting that intestinal passive diffusion was enhanced, whereas ileal active transport might be reduced. Basal hepatic secretion ...
An aerial radiological survey was performed from 11 to 20 March 1982 over a 260-square-kilometer area centered on the Grand Gulf Nuclear Station at Port Gibson, Mississippi (the station was not yet in operation at the time of the survey). All gamma ray data were collected by flying east-west lines spaced 152 meters apart at an altitude 91 meters above ground level. Processed data showed that all gamma rays detected within the survey area were those expected from naturally occurring terrestrial background emitters. Count rates obtained from the aerial platform were converted to exposure rates at 1 meter above the ground and are presented in the form of an isoradiation contour map. The observed exposure rates were between 5 and 13 microroentgens per hour (#mu#R/h), with most of the area ranging from 9 to 10 #mu#R/h. These values include an estimated cosmic ray contribution of 3.6 #mu#R/h. The exposure rate obtained from soil samples and ionization ...
The APMP/TCRI Dosimetry Working Group performed the APMP.RI(I)-K3 key comparison of measurement of air kerma for medium-energy x-rays (100 kV to 250 kV) between 2000 and 2003. In total, 11 institutes took part in the comparison, among which 8 were APMP member laboratories. Two commercial cavity ionizationchambers were used as transfer instruments and circulated among the participants. All the participants established the 100 kV, 135 kV, 180 kV and 250 kV x-ray beam qualities equivalent to those of the BIPM. The results showed that the maximum difference between the participants and the BIPM in the medium-energy x-ray range, evaluated using the comparison data of the linking laboratories ARPANSA and PTB, is less than 1.4%. The degrees of equivalence between the participants are presented and this comparison confirms the calibration capabilities of the participating laboratories. (authors)
An extensive set of benchmark measurement of PDDs and beam profiles was performed in a heterogeneous layer phantom, including a lung equivalent heterogeneity, by means of several detectors and compared against the predicted dose values by different calculation algorithms in two treatment planning systems. PDDs were measured with TLDs, plane parallel and cylindrical ionizationchambers and beam profiles with films. Additionally, Monte Carlo simulations by meansof the PENELOPE code were performed. Four different field sizes (10x10, 5x5, 2x2, and1x1 cm"2) and two lung equivalent materials (CIRS, #rho#_e"w=0.195 and St. Bartholomew Hospital, London, #rho#_e"w=0.244-0.322) were studied. The performance of four correction-based algorithms and one based on convolution-superposition was analyzed. The correction-based algorithms were the Batho, the Modified Batho, and the Equivalent TAR implemented in the Cadplan (Varian) treatment planning system and ...
Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle"3 treatment planning system, and the dose was calculated in a water phantom. Ionizationchamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as well as its spatial dosimetric characteristics. Results: Agreement within 5.0% was observed between the Pinnacle"3 predicted dose distributions and the ...
The work presented in part 1 of this study established that the sorption of anhydrous HX into dehydrated Na{sub 56}Y progresses through a sequence of steps involving HX ionization and charge separation, oxygen framework protonation, formation of {alpha}-cage confined cation-anion contact ion pairs, and proton solvation by HX. A logical extension, which is the subjected of this study, concerns the effect of extraframework alkali metal cation type (M = Li{sup +}, Na{sup +}, K{sup +}, Rb{sup +}, Cs{sup +}) on the sorption process. The question of the acidity of proton-loaded zeolites compared to Broensted acid zeolites is addressed by using probe reactions with weak bases like ethane and cyclopropane. Additional insight into these systems is also obtained from a quantitative comparison of the kinetic and thermodynamic activation parameters for the dehydrohalogenation of proton-loaded zeolites exemplified by (HX){sub 8}Na{sub 56}Y relative to the ...
This study was carried out to evaluate the biochemical and morphological effects of ionizing radiation on ovary. Immature mice (ICR, 3 week-old) were irradiated at a dose of LD{sub 80(30)} at KAERI. The ovaries were collected after 6 hours, 12 hours, 1 day, and 2 days post irradiation. To analyze the morphological changes, histological staining with hematoxylin-eosin, immuno- histochemical preparation using in situ 3'-end labeling was performed. DNA fragmentation analysis and flowcytometric evaluation of DNA extracted from whole ovary were performed. As a result of DNA fragmentation analysis, DNA fragments with 185, 370, and 555 base pairs were clearly shown at 6 hours post irradiation. The percentage of A{sub 0} cell cycle was significantly increased in the irradiated group than control. In situ 3'-end labeled follicles were increased at 6 hours post irradiation. The radiation-induced follicular atresia was taken place via an ...
Radioactive ion beams (RIBs) of short-lived isotopes of fluorine are in demand for investigating astrophysical phenomena related to the hot CNO cycle and rp processes responsible for stellar nucleosynthesis. Since negative ion beams are required for injection into tandem electrostatic accelerators, such as the 25 MV tandem accelerator used for post acceleration of RIBs for the Holifield Radioactive Ion Beam Facility (HRIBF) research program at the Oak Ridge National Laboratory (ORNL), efficient, direct-formation F{sup -} ion sources are highly desirable for RIB applications involving this type of post-accelerator. We have conceived and evaluated a direct extraction F{sup -} source for potential RIB applications which is predicated on the reverse polarity operation of a positive electron-beam-plasma target/ion source (EBPTIS) while simultaneously feeding fluorine rich compounds and Cs vapor into the source. The source is found to operate in two separately distinct temperature regimes ...
An apparatus is described for measuring the overall decontamination factor of first and second filters, the first and second filters being located in a plenum having an upstream chamber, an intermediate chamber, and a downstream chamber. The first filter is located between the upstream and intermediate chambers and the second filter is located between the intermediate and downstream chambers. The apparatus comprises a. an aerosol generator for producing a challenge aerosol composed of individual particles, the aerosol generator being in fluid communication with the upstream chamber; b. an upstream collector for collecting the challenge aerosol before the challenge aerosol enters the first filter, the upstream collector being disposed in the upstream chamber; c. an intermediate collector for collecting the challenge aerosol that passes ...
Superfluidity in fermionic systems originates from pairing of fermions, and Bose condensation of these so-called Cooper pairs. The Cooper pairs are usually made of fermions of different species; for example in superconductors they are pairs of electrons with opposite spins. Thus the most favorable situation for pairing and superfluidity is when the two species of fermions that form pairs have the same density. This paper studies the possible superfluid states when the two pairing species have different densities, and show that the resultant states have remarkable similarities to the phases of liquid crystals. This enables us to provide a unified description of the possible pairing phases, and understand the phase transitions among them.
A fuel injector comprises first and second housing parts, the first housing part being located within a bore or recess formed in the second housing part, the housing parts defining therebetween an inlet chamber, a delivery chamber axially spaced from the inlet chamber, and a filtration flow path interconnecting the inlet and delivery chambers to remove particulate contaminants from the flow of fuel therebetween.
A multiwire cylindrical drift chamber is the main detector of the AMPIR 4#pi#-spectrometer for studying pion-nucleon reactions. The chamber has possibility to measure three coordinates by the electron drift time and by the charge division method. Chamber design and geometry, test bench, readout electronics and also results of calculations, simulation and tests are described.
A cylindrical multiwire drift chamber is the central detector of the AMPIR spectrometer. It has 4{pi} acceptance angle and was designed to study pion-nucleon reactions. The chamber can determine the three coordinates through the electron drift time and charge division ration. The paper describes the layout and design of the chamber, the test bench, the data output circuit, the design parameters, and the results of computer simulations and tests.
A cylindrical multiwire drift chamber is the central detector of the AMPIR spectrometer. It has 4#pi# acceptance angle and was designed to study pion-nucleon reactions. The chamber can determine the three coordinates through the electron drift time and charge division ration. The paper describes the layout and design of the chamber, the test bench, the data output circuit, the design parameters, and the results of computer simulations and tests.
To evaluate the contribution of genetic influences on the individual variation in plateau serum salicylate levels, salicylate metabolism was studied in seven pairs of identical and six pairs of fraternal...Full Text Available
The risks of genetic, leukemia and malignant diseases from medical X-ray diagnostic examinations were estimated using the frequency of radiographic and fluoroscopic exposures per diagnostic examination, child expectancy, leukemia and malignancy significant factors, and using a weighting factor determined on the basis of data concerning the cancer mortality among atomic bomb survivors in Nagasaki and of a recommendation of International Commission of Radiological Protection. The organ or tissue doses with respect to the stochastic risks were determined with ionizationchambers and thermoluminescent dosimeters placed at the positions of the organs or tissues in a RANDO woman phantom which was exposed to diagnostic X-rays according to technical factors of typical radiographic and fluoroscopic examinations obtained from a nationwide survey. The resultant risks by age-group and type of radiographic and fluoroscopic examination are tabulated in terms ...
Cylindrical test pieces of concrete are used for measurements of "2"2"2Rn exhalation rates. Except one flat end surface of a test piece, other parts of its exteriority are covered with sealant. Radon atoms can escape only through its end surface from the interior into the outside air. This treatment makes the radon transport in the concrete one dimensional phenomena. The piece is put in an airtight container. Time variations of radon concentrations in the air of the container are measured with a plane multiwire-electrode ionizationchamber. From this result, the radon areal exhalation rate is deduced for the piece. Exhalation rates are measured for four pieces with different length. Then, the diffusion coefficient is obtained for radon in the concrete as (5.0 #+-# 1.0) x 10"-"8m"2s"-"1 (a one-block method). A two-block method has been invented to obtain simultaneously values of three parameters: diffusion coefficient, porosity of concrete, and ...
In this work tests of quality control in beams of X rays have been carried out, at diagnostic level, of two radiological services equipments of Brazilian hospitals (Aracaju, SE). We obtained the air kerma and kerma rate values, the beams efficiency, the coherence between the luminous fields and the referring fields of irradiation and half-value layer to each equipment and set of parameters. The measures of direct form have been obtained using two ionizationchambers, one cylindrical and another one with parallel plates. An optional method for accomplishment some of the tests were carried out with CaSO{sub 4}:Dy + Teflon thermoluminescent dosimeters. The values of air kerma were evaluated for three tube voltage, 40, 60 and 81 kV at 1.0 m from the focus of the equipments. For each one of the voltages three distinct current values were chosen besides a fixed value of exposition time. The results showed that the values of air kerma varied between ...
As a series of estimations of population doses and of risk estimates from medical exposures in Japan, the malignancy significant dose (MSD) and the fatal malignant risk from beam therapy were estimated based on a nationwide survey of radiotherapeutic treatments, using a malignancy significant factor and a weighting factor determined from the data on the cancer mortality among the atomic bomb survivors in Nagasaki. The effective dose was defined as a sum of the product of the weighting factor and the organ or tissue doses with respect to the malignant diseases. The organ or tissue doses were determined with ionizationchambers placed at the positions of their center in a MixDp-phantom simulated lung tissues by a block of cork, using a telecobalt unit, a conventional X-ray unit and a medical linear accelerator. The organ or tissue doses were categorized into three dose components; namely 1) dose from useful beams; 2) scattered radiation dose from ...
'Improvement in understanding of the deposition of ambient dust particles on ECAM (Environmental Continuous Air Monitor) filters, reduction of the alpha-particle interference of radon progeny and other radioactive aerosols in different particle size ranges on filters, and development of ECAM''s with increased sensitivity under dusty outdoor conditions. As of May 1, 1998 (1/2 year into the project) the research-prototype 30-cm pulsed ionizationchamber (PIC) is assembled and operational with an alpha particle energy resolution of better than 45 keV for 5-MeV alpha particles. Measurements of spectral resolution for alpha particles from radon decay products have been made as a function of filter type and dust loading conditions. So far, a study of ten filter types has found that the best combination of resolution and throughput is obtained with 3.0 \\265m Millipore fluoropore and 1.0 \\265m Corning FNMB filters. ...
The "2"3"3U(n,f) cross section has been measured at the white neutron source n_TOF in a wide energy range with a dedicated fission ionizationchamber. We report here the results from #approx#30 meV to 1 MeV neutron energy. The "2"3"3U(n,f) cross section has been determined relative to a reference sample of "2"3"5U(n,f) measured simultaneously with the same detector. The very high instantaneous neutron flux and the intrinsically low background of the n_TOF installation result in an accuracy around 3% in the whole energy range, while the energy resolution of the neutron beam allows for an accurate description of the fission cross section by means of R-matrix analysis over a wide energy range. The results are, in general, in good agreement with the most recent high-accuracy measurement of this fission cross section, over the more limited range of the previous measurements, and indicated that even the latest evaluations underestimate the cross ...
A method and apparatus for operating a compression ignition engine having a cylinder wall, a piston, and a head defining a combustion chamber. The method and apparatus includes delivering fuel substantially uniformly into the combustion chamber, the fuel being dispersed throughout the combustion chamber and spaced from the cylinder wall, delivering an oxidant into the combustion chamber sufficient to support combustion at a first predetermined combustion duration, and delivering a diluent into the combustion chamber sufficient to change the first predetermined combustion duration to a second predetermined combustion duration different from the first predetermined combustion duration.
A two module electron beam source operating over a wide range of output parameters has been designed and fabricated to be used in conjunction with a pair of electron beam sustained CO_2 lasers. Each module comprised a grid-controlled thermionic electron beam gun including a compact grid pulser for control of the electron beam, a 250 kV thyratron switched modulator for acceleration of the electron beam, a 1 kHz filament heater and a complex computerized control system. The system was designed to reliably produce 45 #mu#s wide electron pulses of 150-200 keV energy, operate at repetition rates of 1-10 pps and current densities of 5-20 mA/cm"2. Additional parameters are listed. The high voltage cathode assembly employs 132 thoriated tungsten filaments distributed over the area of the 250 cm x 10 cm output window. The cathode assembly including the control grids is supported by two high voltage ceramic bushings in a stainless steel vacuum chamber. ...
Presently, most charge state distributions produced with highly charged ion sources are predicted with models that approximate the ionization process with the Lotz formula. The Lotz ionization cross sections decrease approximately geometrically with increasing charge state except for ions with very few vacancies, for ions with very few electrons, and for electron impact energies which barely exceed the ionization energy. The geometrical decrease causes these models to predict a maximum abundance for most of the charge states, which is only weakly dependent on the charge state. Experimental results, however, yield much higher abundances for ions with an empty M shell than ions with a partly filled M shell. This difference is explained with indirect ionization processes that are neglected by the Lotz approximation, and normally can be neglected for the ionization of the L shell, but ...
A burner system particularly useful for downhole deployment includes a tubular combustion chamber unit housed within a tubular coolant jacket assembly. The combustion chamber unit includes a monolithic tube of refractory material whose inner surface defines the combustion zone. A metal reinforcing sleeve surrounds and extends the length of the refractory tube. The inner surface of the coolant jacket assembly and outer surface of the combustion chamber unit are dimensioned so that those surfaces are close to one another in standby condition so that the combustion chamber unit has limited freedom to expand with that expansion being stabilized by the coolant jacket assembly so that compression forces in the refractory tube do not exceed about one-half the safe compressive stress of the material; and the materials of the combustion chamber unit are selected to establish thermal gradient ...
The National Ignition Facility (NIF) is a proposed Department of Energy facility which will contribute to the resolution of important Defense Program and inertial fusion energy issues for energy production in the future. The NIF will consist of a laser system with 192 independent beamlets transported to a target chamber. The target chamber is a multi-purpose structure that provides the interface between the target and the laser optics. The chamber must be capable of achieving moderate vacuum levels in reasonable times; it must remain dimensionally stable within micron tolerances, provide support for the optics, diagnostics, and target positioner; it must minimize the debris from the x-ray and laser light environments; and it must be capable of supporting external neutron shielding. The chamber must also be fabricated from a low neutron activation material. The fusion reaction in the target gives off ...
We performed a prospective study evaluating the 2-year success rate of extracapsular cataract surgery and posterior chamber IOL insertion performed in 610 eyes by an experienced surgeon in the Nepal...Full Text Available
... Radon gas concentrations are measured using instruments with calibrations traceable to the UK National Physical Laboratory and PTB, Germany. The primary facility is a 43 m3 walk-in chamber accessed by an airlock. Radon gas is maintained at a level in this chamber that is ...
A device for reducing the muzzle blast and flash from large caliber guns is disclosed. A container having a plurality of internal chambers and baffle plates filled with an aqueous foam is mounted to the muzzle of the gun barrel. The foam and chambers co-o...
Purpose:To investigate the clinical usage of dose verification of Helical Tomotherapy plans by using 2D-array ion chambers, and to develop an efficient way to validate the dose delivered...Full Text Available
This brief paper is an introduction to the concept of designing residential warm air furnaces without combustion chambers. This is possible since some small burners do not require the thermal support of a combustion chamber to complete the combustion process.
We report on the discovery of kinematic shock signatures associated with a localized radio jet interaction in the merging Seyfert galaxy NGC 5929. We explore the velocity-dependent ionization structure of the gas and find that low-ionization gas at the interaction site is significantly more disturbed than high-ionization gas, which we attribute to a local enhancement of shock ionization due to the influence of the jet. The characteristic width of the broad low-ionization emission is consistent with shock velocities predicted from the ionization conditions of the gas. We interpret the relative prominence of shocks to the high density of gas in the nuclear environment of the galaxy and place some constraints of their importance as feedback mechanisms in Seyferts.
Research conducted since the last progress report includes the synthesis and characterization of twenty three novel proton-ionizable crown ether compounds. Metal ion complexation behavior of new and previously-synthesized proton-ionizable crown ether compounds has been probed by solvent extraction and transport across polymer-supported liquid membranes. The behavior of neutral polyether and proton-ionizable polyether ligands in polymeric membrane electrodes has been assessed. Studies of the use of proton-ionizable crown ethers for separation of lithium isotopes were initiated. Also, the thermodynamics of interactions between alkali metal cations and ionized crown ethers have been probed by titration calorimetry. 10 refs., 1 tab.
The conceptual design of the support structures of the EM muon chambers is presented. On each side of the detector the EM chambers are arranged in four layers: one layer of MDTs and the three layers of TGCs. The chambers are mounted on four individual wheel structures per side. The four wheels are inclined by 1.23% and suspended from two longitudinal beams parallel to the beam axis. In order to allow for the opening of the ATLAS detector the wheels can be displaced longitudinally over a distance of 6 m. In addition individual wheels can be separated from each other by up to 1 m for maintenance purposes.
Parameters of the vortex air flow in an isothermal model of the cyclone chamber are studied. The effect of the air velocity in nozzles on the values and character of the distribution of pressure and tangential and longitudinal velocities of air in the chamber is determined. Numerical modeling of the flow is performed, and it is shown that numerical calculation by the k-w turbulence model is in agreement with experimental data.
The neutron detector is cased in a metal envelop and has one detector with a very sensitive fission chamber and a second detector with a fission chamber less sensitive that the first one and a boron coated ionisation chamber for reducing gamma radiation detection.
In this first quarterly technical report for DOE Contract No. DE-AC22-87PC79654, a description of the background, technology, and application is provided. The design and fabrication of advanced combustion chambers were completed during this period. Initial testing on both the bare metal and refractory lined advanced chambers were initiated. The units were tested initially with gas but primarily with coal. A Pittsburgh No. 8 pulverized coal was used for these test activities. Both advanced chambers pulsed well.
Since the most efficient way to improve fuel economy in the part-load range is to increase the compression ratio, emphasis is placed on combustion chambers allowing high compression ratios combined with low octane requirements. According to Porsche experience, many demands can be met in the simplest manner by locating the combustion chamber in the piston crown. This configuration offers various advantages over its counterpart installed in the cylinder head. 24 refs.
For the step-and-shoot intensity-modulated radiation therapy (IMRT) technique, the combination of high dose rate, multiple beam segments and low dose per segment can lead to significant differences between the planned dose and the dose delivered to the patient. In this technique, a dose delivery inaccuracy known as the 'overshoot' effect is caused by the dose servo control system. This typically occurs in the first and last beam segments and causes an over- and underdose, respectively. Some dose positional error in the segment sequence is also possible there. Commercial ionizationchambers (RK-type) and radiographic Kodak films were used for the measurements. The reported results were obtained using the Pinnacle{sup 3}-V6.2 treatment planning system and a Varian Clinac 21 EX linear accelerator equipped with a 120-leaf Millennium MLC. The dose inaccuracy measurements were based on the comparison of the dose and profiles for ...
The goal of this work is to present a systematic Monte Carlo validation study on the clinical implementation of the enhanced dynamic wedges (EDWs) into the Pinnacle"3 (Philips Medical Systems, Fitchburg, WI) treatment planning system (TPS) and QA procedures for patient plan verification treated with EDWs. Modeling of EDW beams in the Pinnacle"3 TPS, which employs a collapsed-cone convolution superposition (CCCS) dose model, was based on a combination of measured open-beam data and the 'Golden Segmented Treatment Table' (GSTT) provided by Varian for each photon beam energy. To validate EDW models, dose profiles of 6 and 10 MV photon beams from a Clinac 2100 C/D were measured in virtual water at depths from near-surface to 30 cm for a wide range of field sizes and wedge angles using the Profiler 2 (Sun Nuclear Corporation, Melbourne, FL) diode array system. The EDW output factors (EDWOFs) for square fields from 4 to 20 cm wide were measured in virtual water using a small-volume ...
This paper presents the isothermal characteristics of methanol onto two specimens of activated carbons namely Maxsorb III and Tsurumi activated charcoal. Dubinin Raduskevich (D-R) equation is used to correlate the adsorption isotherms and to form the pressure-temperature-concentration diagram for both of the assorted pairs. Experimental results show that the maximum adsorption capacity of Maxsorb III/methanol pair is 1.76 times that of activated charcoal/methanol pair. Employing a time-independent mathematical model, the performance of adsorption cooling cycle using Maxsorb III/methanol and activated charcoal/methanol pairs has been studied and compared with that of three other types of carbon based adsorbent/methanol pairs. Theoretical calculations show the superiority of Maxsorb III/methanol pair for both of air-conditioning and ice-making applications. ...
The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).
The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).
Although skin is usually exposed during human exposures to ionizing radiation, there have been no thorough examinations of the transcriptional response of skin fibroblasts and keratinocytes...Full Text Available
This thesis describes the analysis of the semileptonic decay D{sup 0} {yields} {bar K}{sup 0} {pi}{sup -} {mu}{sup +}{nu} using FOCUS data. FOCUS is a fixed target experiment at Fermilab that studies the physics of the charm quark. Particles containing charm are produced by photon-gluon fusion from the collision of a photon beam on a BeO target. The experiment is characterized by excellent vertex resolution and particle identification. The spectrometer consists of three systems for track reconstruction (two silicon systems and one multiwire proportional chamber system) and two magnets of opposite polarity. The polarity of the magnet is such that the events of e{sup +}e{sup -} pairs produced in the target (which constitutes the main background) travel through a central opening in the detectors without interactions. Particle momentum is measured from the deflection angle in the magnets. Three multicell Cerenkov counters are used for charged ...
Abstract Ionizing radiation is a ubiquitous feature of the Cosmos, from exogenous cosmic rays (CR) to the intrinsic mineral radioactivity of a habitable world, and its influences on the emergence and persistence of life are wide-ranging and profound. Much attention has already been focused on the deleterious effects of ionizing radiation on organisms and the complex molecules of life, but ionizing radiation also performs many crucial functions in the generation of habitable planetary environments and the origins of life. This review surveys the role of CR and mineral radioactivity in star formation, generation of biogenic elements, and the synthesis of organic molecules and driving of prebiotic chemistry. Another major theme is the multiple layers of shielding of planetary surfaces from th...
The ionization, excitation, and radiative recombination rates for highly stripped ions are cal- culated with Maxwellian and non-Maxwellian electron distribution functions of the type Cmexp(-vm/wm) (2<=m<=5) as encountered in laser-heated plasmas and certain types of turbulent plasmas. The direct-radiative-recombination rates are found to decrease by at most 30% as m is increased from 2 to 5. On the other hand, the ionization and excitation rates are found to be strongly reduced if the transition energy ? exceeds twice the local temperature kBTe. The effect of this on the distribution of energy levels and degrees of ionization in laser-produced plasmas could be important.
The CDF II eXtremely Fast Tracker (XFT) is the trigger processor which reconstructs charged particle tracks in the CDF II central outer tracking chamber. The XFT tracks are also extrapolated to the electromagnetic calorimeter and muon chambers and are associated to electromagnetic clusters and muon stubs to generate trigger electron and muon candidates. The steady increase of the Tevatron instantaneous luminosity and the resulting higher occupancy of the chamber demanded an upgrade of the original system, which performed tracking only in the transverse plane of the chamber and was consequently affected by a significant level of fake tracks. In the upgraded XFT, tracking is reinforced by using additional data from the stereo layers of the chamber to reduce the level of fake tracks and to perform three-dimensional track reconstruction. A review of this upgrade is presented.
This chapter is concerned with standards and guidances for limiting radiation exposures. It is divided into three sections, each of which has several parts. Section 1: Ionizing Radiation -- Standards and Guidances Applicable to the Public: Part A, Radiation Protection Standards; Part B, Environmental Radiation Standards; Part C, Exempt Levels of Radioactivity; Part D, Protective Action Guides for Accidents. Section 2: Ionizing Radiation -- Standards Applicable to the Workplace. Section 3: Medical and Other Standards.
Effect of single and chronic irradiation on factors of hamsters natural immunity such as complement, lysozyme and antibodies in norm and in the cestode invasion has been investigated. Significant phase changes in the complement activity level, lysozyme content and specific antibodies tite have been shown to occur in hamster blood under the influence of ionizing radiation. Cestode invasion in irradiated host organism increases the negative effect of ionizing radiation on the hamster immyne system.
A spherical-geometry, self-extraction negative ion source has been designed and fabricated. The source utilizes direct surface ionization to form negative ion beams resulting from interactions between high electron affinity gaseous elemental or molecular materials and a negatively biased, spherical-sector LaB{sub 6} surface ionizer maintained at {similar to}1300 K. The design features of this source and principles upon which the source is based are discussed in this report.
Device for separating and collecting ultrafine atomized powder from the gas stream of a gas atomizing apparatus comprises a housing having an interior wall oriented at an angle relative to horizontal so as to form a downwardly converging, conical expansion chamber, an inlet conduit communicated to the expansion chamber proximate an upper region thereof for receiving the gas stream, and an outlet proximate a lower region of the expansion chamber. The inlet conduit is oriented at a compound inclined angle (with respect to horizontal) selected to promote separation and collection of powder from the gas stream in the expansion chamber. The compound angle comprises a first entrance angle that is greater than the angle of repose of the powder on the housing interior wall such that any powder accumulation in the inlet conduit tends to flow down the wall toward the outlet. The second angle is selected generally ...
Operation safety and reliability are major guidelines in the design of city-gate units. Conventional natural gas heaters operate by a indirect mechanism, where liquid water is used to transfer heat by natural convection between the combustion chamber and the natural gas coil. In this work, the concept of vapor chamber is evaluated as an indirect gas heater. In a vapor chamber, liquid water is in contact with the heat source, and vaporizes. The vapor condenses in contact with the heat sink. A reduced scale model was built and tested in order to compare these two heating concepts where the combustion chamber was replaced by electrical cartridge heaters. This engineering model can operate either as a conventional heater or as a vapor chamber. The comparison between the concepts was done by inducing a controlled power to the cartridges and by measuring the resulting temperature ...
180 deg magnet chamber is used in Folded Tandem Ion Accelerator for passage and 180 deg bending of ion beam. The chamber is placed between 180 deg terminal magnet (Electro-magnet), which is used for bending, and analysing the beams. Magnet with a particular magnetic field strength bends ions of only specified mass energy product through a precise path. There is also a space limitation in the direction of magnetic field. Both of them require the magnet chamber to be of a close tolerance. Accuracy of center distance between inlet and outlet port of the magnet chamber has to be at par with the concentricity of high energy and low energy beam line. To achieve this we started the fabrication of magnet chamber by following two methods: a) Circular rolling and bending of rectangular tube for 180 deg sector of magnet chamber b) Machining 180 deg sector in two half and ...
Sequence-directed variations in the canonical DNA double helix structure that retain Watson-Crick base-pairing play important roles in DNA recognition, topology, and nucleosome positioning....Full Text Available
Overviews, publications, and new directions are presented for the following research topics: geminate charge pairs in hexane, dipoles in nonpolar and polar organic liquids, organic donor-acceptor interfaces, and charge-transfer states (phenanthrene/PMDA).
The EMS effect is explained in the flucton model as a consequence of scale invariance violation. Nontrivial behaviour of the ratio between structural functions and production cross sections for lepton pairs for different nuclei at x > 1 is predicted.
A pneumatic device is in the form of a U-shaped frame, on which a prong is attached by using two pairs of levers. It also has a hydraulic or pneumatic cyclinder, whose rod is connected to one of the pairs of levers. All connections are hinges.
of increasing numbers of vortices as a function of the thickness. Vortices are these whirlpool shaped structures. They are interesting because they come paired with...
Positron-electron pair creation near the threshold energy is extremely difficult to investigate by both experiments and theory. First test experiments were performed at the ILL to determine the cross sections for positron-electron pair creation near threshold using prompt {gamma}-rays from different targets after neutron capture and conventional radioactive sources. Pair creation was studied in a Ge detector, which simultaneously acted as sample and detector. First results are presented which show a significant deviation from theoretical values near threshold.
Recently, Wang et al. proposed a three-party simultaneous quantum secure direct communication (3P-SQSDC) scheme with EPR pairs, which enables three involved parties to exchange their secret messages simultaneously by using an EPR pair. This work proposed an enhancement on Wang et al.'s scheme. With the enhancement, the communications in the improved 3P-SQSDC can be paralleled and thus improves the protocol efficiency.
Pairing correlations in multi-quasiparticle states in deformed nuclei are expected to be reduced because of blocking. New intrinsic states and their associated rotational bands have been identified allowing comparisons to be made as a function of seniority and between nuclei. The possible effects of the reduced pairing on the collective rotation, and its manifestation in terms of alignment, are discussed. 13 refs., 2 figs.
The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an {sup 55}Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For ...
Simultaneous reduction of NO{sub x} and particulate emissions in a direct-injection diesel engine has been realized experimentally with a high squish combustion chamber. The purpose of this study is to investigate the effects of high squish combustion chamber on combustion process in detail. Engine CFD code FREC was used for the analysis. The results show the followings. (1) Compared with standard toroidal chamber, high squish chamber generates high turbulence due to strong squish and large expansion flow is caused in the cavity. (2) Rich and high-turbulence combustion, which forms ring area in the cavity under squish lip, continues during the combustion. (3) The high squish combustion chamber keeps fuel long in the cavity and less hid spreads out to the cold clearance volume. (4) For the condition of retarded injection timing, the effect of high squish is mainly observed at initial ...
This paper describes the experimental results of accelerated aging tests conducted on three different types of polymer materials. Salt fog chamber tests were used to study the surface degradation modes for all materials. The work presented here was performed using a newly constructed fog chamber system that was able to control both chamber humidity and UV radiation. The changes in the surface morphology, material structure and leakage current were examined to study the influence of environmental humidity.
In this first quarterly technical report for DOE Contract No. DE-AC22-87PC79654, a description of the background, technology, and application is provided. The design and fabrication of advanced combustion chambers were completed during this period. Initial testing on both the bare metal and refractory lined advanced chambers were initiated. The units were tested initially with gas but primarily with coal. A Pittsburgh No. 8 pulverized coal was used for these test activities. Both advanced chambers pulsed well.
A pump down model for a vacuum chamber with a reversibly adsorbed phase is presented. The outgassing equation which predicts the variation of coverage at the wall surface of a vacuum chamber with time is derived. Then the measured and the true outgassing rates are defined. The theoretical measured outgassing rate shows only a very weak dependence for pumping speed. This prediction is opposite to the experimental result that the measured outgassing rate depends significantly on pumping speed. It is discussed that the experimental measured outgassing rate must be described as the product of the effective pumping speed and the measured pressure in the pumped chamber, in which the measured pressure is equivalent to the equilibrium pressure of the wall surface described by the equilibrium adsorption isotherm as a function of the shifted surface coverage {theta}-{delta}{theta} by a small coverage {delta}{theta} from the coverage ...
In order to realize simultaneous reduction of NO{sub x} and Particulate emissions, effects of combustion chamber geometry were investigated in a high speed direct-injection diesel engine. The reentrant combustion chambers with different throat diameter were compared in terms of engine performance, combustion characteristics and emissions such as NO{sub x}, particulate and THC. The phenomena of combustion process were also observed with endoscopic high speed photography. The results showed that when the throat diameter of a reentrant combustion chamber was reduced to an extent, NO{sub x} and particulate decreased simultaneously due to retarded injection timing and the intensified squish. (author)
SummaryThe polarized nature of neurons as well as the size and density of synapses complicates the manipulation and visualization of cell biological processes that control synaptic...Full Text Available
Some non-human animals may possess the ability to recall the "what", "where", and "when" of a single past event. We tested the hypothesis that male meadow voles possess the capacity to recall the "what", "where", and "when" of a single past event associated with mate selection in two experiments. Briefly, male voles were allowed to explore an apparatus that contained two chambers. One chamber contained a day-20 pregnant female (24 h prepartum). The other chamber contained a sexually mature female that was neither pregnant nor lactating (REF female). Twenty-four hour after the exposure, the males were placed in the same apparatus, which was empty and clean. At this time, the pregnant female would have entered postpartum estrus (PPE), a period of heightened sexual receptivity. Males initially chose and spent significantly more time investigating the chamber that originally housed the pregnant female (now ...
The most serious challenges in the design of chambers for inertial fusion energy (IFE) are 1) protecting the first wall from fusion energy pulses on the order of several hundred megajoules released in the form of x rays, target debris, and high energy neutrons, and 2) operating the chamber at a pulse repetition rate of 5-10 Hz (i.e., re-establishing, the wall protection and chamber conditions needed for beam propagation to the target between pulses). In meeting these challenges, designers have capitalized on the ability to separate the fusion burn physics from the geometry and environment of the fusion chamber. Most recent conceptual designs use gases or flowing liquids inside the chamber. Thin liquid layers of molten salt or metal and low pressure, high-Z gases can protect the first wall from x rays and target debris, while thick liquid layers have the added benefit of protecting ...
A design is proposed for forming the rear screen of a chamber firebox at the point of aerodynamic projection and a design for attaching the pipes of the aerodynamic projection using girders linked with the screen by hinges and movable connections.
The work presented here demonstrates the ability of proton-transfer-reaction mass spectrometry (PTR-MS) to perform fast-response measurements of volatile organic compounds (VOCs) (including methanol, acetonitrile, acetaldehyde, acetone, PAN-type compounds, alpha- and beta-pinene, nopinone and pinonaldehyde) at the pptv level and its versatile applicability in the field of environmental trace gas analysis. Laboratory and field experiments including various calibration techniques and intercomparisons with other measurement techniques such as gas chromatography, atmospheric pressure chemical ionization and Fourier transformation infrared spectroscopy were performed providing a first characterization of the PTR-MS instrument performance (sensitivity, detection limit, precision, accuracy). Typically a detection limit (S/N=2) of 50 pptv for a 10 s signal integration time, a precision of 5 % and an accuracy in the range between 10 and 25 % were observed. Due to its ...
We have measured the K-shell ionization probability across the 6.06-MeV resonance in /sup 88/Sr(p,p/sub 0/) where the resonance width is large compared to the energy transferred to the electron. The results are found to agree quantitatively with the theory developed by Blair and Anholt. The effect of the time delay on the ionization probability, introduced by the nuclear scattering at the resonance energy, is discussed.
The crossed electron-ion beams technique was used to measure absolute cross sections for single ionization of Ar"2"+, Kr"2"+ and Xe"2"+ ions at electron energies ranging from threshold to 2000 eV. In contrast to some previous measurements, the metastable contents of the ion beams were small even in the case of Xe"2"+. All measured cross section curves show significant contributions from excitation-autoionization and possibly direct ionization of inner-shell electrons. There is evidence for resonance-excitation-double-autoionization in the case of Xe"2"+. (author).
Photoelectron resonance capture ionization (PERCI) is a soft and sensitive ionization method, based on the attachment of low-energy (<1 eV) photoelectrons to organic analyte molecules. PERCI has been developed in our laboratory for the real-time analysis of organic particles by mass spectrometry, and is employed here to monitor the heterogeneous reaction of ozone with oleic acid. Simplified identification of the reaction products is possible as a result of the soft nature of PERCI, giving predominantly the [M--H](-) ions. The major particle-phase products are identified as: 1-nonanal, nonanoic acid, 9-oxononanoic acid, and azelaic acid, consistent with proposed mechanisms. New insight into this well-studied heterogeneous reaction is gained as additional minor particle-phase products, consistent with the Criegee mechanism, are readily detected. PMID:15468105
Rotifers of class Bdelloidea are common invertebrate animals with highly unusual characteristics, including apparently obligate asexuality, the ability to resume reproduction after desiccation at any...Full Text Available
An estimate for the number of ionizing photons per baryon as a function of redshift is computed based on the plausible extrapolation of the observed galaxy UV luminosity function and the latest results on the properties of the escape fraction of ionizing radiation. It is found that, if the escape fraction for low mass galaxies (Mtot<10^{11}Msun) is assumed to be negligibly small, as indicated by numerical simulations, then there are not enough ionizing photons to reionize the universe by z=6 for the cosmology favored by the WMAP 3rd year results, while the WMAP 1st year cosmology is marginally consistent with the reionization requirement. The escape fraction as a function of galaxy mass would have to be constant to within a factor of two for the whole mass range of galaxies for reionization to be possible within the WMAP 3rd year cosmology.
We study the redshift evolution of galaxy pair fractions and merger rates for different types of galaxies using kinematic pairs selected from the DEEP2 Redshift Survey. Parameterizing the evolution of the pair fraction as (1+z)^{m}, we find that the companion rate increases mildly with redshift with m = 0.41+-0.20 for all galaxies with -21 < M_B^{e} < -19. Blue galaxies show slightly faster evolution in the blue companion rate with m = 1.27+-0.35 while red galaxies have had fewer red companions in the past as evidenced by the negative slope m = -0.92+-0.59. We find that at low redshift the pair fraction within the red sequence exceeds that of the blue cloud, indicating a higher merger probability among red galaxies compared to that among the blue galaxies. With further assumptions on the merger time scale and the fraction of pairs that will merge, the galaxy major merger rates ...
The top-color assisted technicolor (TC2) mode predicts the existence of a pair of charged top-pions $\\pi^{\\pm}_t$. In this paper, we study the production of the charged top-pions pair $\\pi^{\\pm}_t$ at next generation $\\gamma\\gamma$ colliders. The results show that the production rates can reach the level of $10^2$ fb with reasonable parameter space. With a large number of events and the clean background, the charged top-pion should be observable at the $\\gamma\\gamma$ colliders. Therefore, our studies can help us to search for charged top-pion, and furthermore, to test the TC2 model.
Three types of drift chambers are being constructed for the Fermilab D/O/ experiment. The construction and readout of these chambers stress good spatial resolution, good two hit separation, and dE/dx. A 106 MHz FADC system with hardware zero suppression is being constructed to readout this system. 8 refs., 12 figs., 1 tab.
A phenomenological model is presented for prediction of the combustion characteristics of a quiescent chamber diesel engine. Predictions with the model have shown acceptable agreement with a range of experimental data. The major physical processes controlling combustion have been characterized, and the dominant role of air entrainment and turbulent mixing confirmed quantitatively. 45 refs.
This is a patent for a device to increase compaction of the loaded batch in a coking chamber that assures a balanced compaction of the batch from the upper to the bottom layer. The leveling rod has a device on the external end that causes the rod to shift vertically and bring pressure on the material and the pressing attachment. Opposite the loading hoppers of the coking chambers there are guides that ensure the rod will be sunk perpendicularly into the loaded material.
The invention concerns an improvement of a cooling device for rotors of multistage axial steam turbines by providing in the first stage of each group of turbine stages a circulation loop connecting the wheel chamber on the inlet side of the rotor disc of the first stage with the wheel chamber on its outlet side. This is to cause the cooling effect not to be hampered by gap widths of the seal in the bottom range of the rotor blades changing during operation. Design particulars are described in detail. (UWI).
A combined gas/steam turbine process includes a high-pressure furnace and a high pressure gasification unit with a mounted upstream of a combustion chamber there is a gas turbine with a waste heat system. Combustion heat which is not needed to heat the flue gas to combustion temperature is released from the furnace and transferred to ths combustion air going into the combustion chamber.
Based on the Weinberg-Salam theory, the competition of the Neutrino Energy Loss (NEL) rates due to the pair, photo- and plasma process are canvassed. The ratio factor C1, C2 and C3 which correspond the different contributions of the pair, photo- and plasma neutrino process to those of the total NEL rates are accurately taken into account. The ratio factors are very sensitive to the temperature and density. The ratio factor C2 always is lower than the ratio factor C1 and C3. The pair NEL process is the dominant contribution before the crossed point O(C1=C3=0.45) and the plasma NEL process will be the main dominant contribution after the crossed point O. With increasing temperature, the crossed point O will move to the direction of higher density. (authors)
We consider the electron-positron pair creation by a photon in an external constant electric field. The presented treatment is based on a purely quasiclassical calculation of the imaginary part of the on-shell photon polarization operator. By using this approach we find the pair production rate for photons with polarization parallel as well as orthogonal to the external electric field in the leading order in the parameter eE/m"2, which has been recently found by other methods. For the orthogonal polarization we also find a new contribution to the rate, which is leading in the ratio of the photon energy to the electron mass #omega#/m. We also reproduce by a purely geometrical calculation the exponential factor in the probability of the stimulated pair creation at arbitrary energy of the photon.
Complex numbers are an intrinsic part of the mathematical formalism of quantum theory and are perhaps its most characteristic feature. In this article, we show that the complex nature of the quantum formalism can be derived directly from the assumption that a pair of real numbers is associated with each sequence of measurement outcomes, with the probability of this sequence being a real-valued function of this number pair. By making use of elementary symmetry conditions, and without assuming that these real number pairs have any other algebraic structure, we show that these pairs must be manipulated according to the rules of complex arithmetic. We demonstrate that these complex numbers combine according to Feynman's sum and product rules, with the modulus-squared yielding the probability of a sequence of outcomes.
An analysis of the cross section for hadronic production of gluino-squark pairs close to threshold is presented. Within the framework of non-relativistic QCD a significant enhancement compared to fixed order perturbation theory is observed which originates from the characteristic remnants of the gluino-squark resonances below the nominal pair threshold. The analysis includes all colour configurations of S-wave gluino-squark pairs, i.e. triplet, sextet and 15 representation. Matching coefficients at leading order are separately evaluated for all colour configurations. The dominant QCD corrections, arising from initial- and final-state radiation are included. The non-relativistic dynamics of the gluino pair is solved by calculating the Green's function in Next-to-Leading Order (NLO). The results are applied to benchmark scenarios, based on Snowmass Points and Slopes (SPS). As a consequence of the large ...
... Using a weighted linear regression on randomly selected coincident SSM/I-buoy pairs from each of the climate m codes, it was possible to produce ...
Leptonic pair production on nuclei ad EMC-effect are discussed within the frames of the flucton model with scaling distortion. Cumulative production of direct photons and leptonic pairs as a test of the model of hard collisions is considered. The results of calculations of massive leptonic pair production cross sections on nucleus fluctons, caculations of the ratio of deuterium and iron structural functions, cross sections of direct photon production on sup(181)Ta nuclei at Esub(p)=400 GeV and cross section of #pi#-meson production in the model of hard collisions are presented. Experimental discovery of direct cumulative photons is concluded to be important for understanding the mechanism of parton hard scattering from nucleus fluctons.
In this paper an efficient quantum secure direct communication (QSDC) scheme with authentication is presented, which is based on quantum entanglement and polarized single photons. The present protocol uses Einstein-Podolsky-Rosen (EPR) pairs and polarized single photons in batches. A particle of the EPR pairs is retained in the sender's station, and the other is transmitted forth and back between the sender and the receiver, similar to the ``ping-pong'' QSDC protocol. According to the shared information beforehand, these two kinds of quantum states are mixed and then transmitted via a quantum channel. The EPR pairs are used to transmit secret messages and the polarized single photons used for authentication and eavesdropping check. Consequently, because of the dual contributions of the polarized single photons, no classical information is needed. The intrinsic efficiency and total efficiency are both 1 in this scheme as ...
Counter rotating longitudinal vortices produced by winglet in a channel are known to enhance heat transfer. In the present investigation the flow structure and heat-transfer enhancement by a winglet pair of non-zero thickness has been studied. A delta winglet pair type vortex generator is placed in a hydrodynamically developed and thermally developing laminar channel flow. Computations are done by solving the unsteady, three-dimensional, incompressible Navier-Strokes equations and energy equation using a modified Marker-and-Cell (MAC) method. The flow structure is complex and consists of main, corner and induced vortices. It is observed that as compared to a channel without winglets, the heat transfer is enhanced by 33% when single winglet is used and by 67% when a winglet pair is employed. Effects of thickness of the winglets and Reynolds number on the heat transfer augmentation are presented.
Electron trapping in crossed electric and magnetic fields is an important mechanism by which electrical discharges can develop in low pressure gases. The authors report observations of discharges produced by this mechanism around a spherical anode in two space simulation chambers, namely the Space Plasma Interaction Experiment (SPIE) at the University of Maryland, and the NASA-Lewis B-2 chamber. They have identified two types of discharges in these experiments. In the B-2 chamber, the breakdown takes the form of a runaway dischage with spherical topology, limited only by the ability of the power supply to provide the current. In the SPIE chamber this type of discharge also occurs, in addition to a low current toroidal discharge which is observed at higher magnetic fields. They present measurements of both types of discharge and show how the trapping effect of the magnetic field together with secondary ...
This study tried to reduce NO{sub x} and particulate emissions simultaneously in a high speed direct-injection diesel engine. Fuel-rich combustion was used to reduce NO{sub x} emission at initial combustion stage and high turbulence combustion was used to reduce particulate emission at diffusion combustion stage. Experiments were carried out to investigate the effects of high squish combustion chambers with small throat on combustion process and exhaust emissions. Results showed that in the high squish combustion chamber, both NO{sub x} and particulate emissions reduced with retarded injection timing. Endoscopic high speed photography was employed to analyze experimental results. In the original combustion chamber at the early combustion stage, the high luminosity flame tended to spread out of the cavity. Fuel-rich mixture burned slowly over the piston crown. In the high squish combustion chamber, flame ...
The activation of nuclear factor-kappa B1 (NFκB1) in cancer cells may confer resistance to ionizing radiation (IR). To enhance the therapeutic efficiency of IR in lung cancer, we screened for...Full Text Available
The cross section database for electron impact excitation and electron impact ionization for hydrogen beam kinetic energies greater than 100 eV was considered, giving for each particular process a reference to a recommended publication of cross sections, as well as the accuracy or estimated accuracy. The work is motivated by the application of neutral beam injection in magnetic confinement devices, such as large tokamaks. 9 refs, 2 figs.
The book is divided into two approximately equal parts. The first four chapters are relatively lengthy and cover the basic principles of radiation biology, carcinogenesis and therapy, along with a brief introduction to radiological physics to orient the reader without background in this specialized related discipline. The remainder consists of twenty-four relatively brief chapters, each covering the radiation biology of a specific organ, tissue, or systems tissues, with emphasis on the tumorigenic and tumoricidal action of ionizing radiations.
Theoretical x-ray transition energies, lifetimes and partial multiplet fluorescence yields are presented for all spectroscopic terms of electron configurations with a single K-shell vacancy and varying number of electrons in the L-shell and M/sub 1/-subshell for multiply-ionized silicon. 9 tables.
The semiclassical approximation with straight-line trajectories is applied to the Coulomb ionization of K, L and M shells by heavy charged particles. The calculational aspects are discussed in detail. Scaling relations for the experimentally relevant quantities are derived. The theoretical predictions are compared with experiment. The relation of the present work to the earlier results of the semiclassical approximation and partial-wave Born approximation is discussed in detail. (author).
This volume of the monograph covers the following topics: activation analysis, non-activation interaction analysis (elastic scattering of charged particles, absorption and backscattering of beta radiation and photons, radionuclide X-ray fluorescence analysis, thermalization, scattering and absorption of neutrons, use of ionization caused by nuclear radiation, use of ionization by alpha or beta radiation for the measurement of pressure, density and flow rate of gases), and automation in radioanalytical chemistry. (P.A.).
Exploding bridgewire (EBW) initiation of high explosives (HE) has been used for many years without a clear understanding of the mechanisms involved. Evidence indicates that the shock pressures produced by the EBW may be insufficient for direct initiation and that the electric field about the wire at the time of burst ionizes the surface of the HE. We hypothesize that the ionization pre-sensitizes the HE so that a weak shock can then initiate a detonation wave. 13 refs., 7 figs.
Organic molecules are a significant and highly varied component of atmospheric aerosols. Measurement of aerosol composition and improvements in our understanding of the complex chemistry involved in their formation and aging are being aided by innovations in soft ionization aerosol MS. (To listen to a podcast about this feature, please go to the Analytical Chemistry multimedia page at pubs.acs.org/page/ancham/audio/index.html.). PMID:21275431
The spontaneous evolution from ultracold Rydberg atoms to plasma is investigated in a caesium MOT by using the method of field ionization. The plasma transferred from atoms in different Rydberg states (n=22-32) are obtained experimentally. Dependence of the threshold time of evolving to plasma and the threshold number of initial Rydberg atoms on the principal quantum number of initial Rydberg states is studied. The experimental results are in agreement with hot-cold Rydberg-Rydberg atom collision ionization theory. (authors)
In the positive column of a neon glow discharge, two different types of ionization waves occur simultaneously. The low-dimensional chaos arising from the nonlinear interaction between the two waves is controlled by a continuous feedback technique. The control strategy is derived from the time-delayed autosynchronization method. Two spatially displaced points of observation are used to obtain the control information, using the propagation characteristics of the chaotic wave.
Cesium ions (Cs"+) are used for the production of the feed ions necessary to obtain Fourier transform mass spectra (FTMS). The molecule chosen for the initial study of this Cs"+ desorption ionization (DI-FTMS) was vitamin B-12 because of its nonvolatile, thermally labile character. 21 references.
A physical explanation is given for the positive differential voltage-current characteristic seen at low current in weakly ionized, low-pressure positive column discharges in argon/mercury gas mixtures. {copyright} {ital 1996 The American Physical Society.}
Two methods to cool muon beams deeply below the limit conventionally established for the ionization cooling are proposed. In Phase Ionization Cooling (PIC), the beam is focused at wedge absorber plates each half of particle oscillation period by imposing a weak parametric resonance along the beam path. The resonance growth of particle amplitude is surmounted by the ionization cooling. At optimum, such arrangement results in reduction of each of two transverse emittances by an order of value in addition to the preceding 6D ionization cooling. Next, resonance focusing and transverse cooling can be continued in the regime of a fast Reverse Emittance Exchange (REMEX). Here, the sign of the absorber wedge is opposite to PIC while the dispersion increased. REMEX to be accompanied by the bunch lengthening and acceleration in order to maintain the relative energy spread at an appropriate level. The limitations ...
The photoelectron resonance capture ionization (PERCI) of cysteine (Cys) and small gas-phase neutral peptides that contain the Cys residue (Cys-Gly, g-Glu-Cys, and glutathione (g-Glu-Cys-Gly)) is reported. At an ionization energy less than 1eV two types of dissociative electron attachment ionization were observed for Cys: hydrogen atom loss, resulting in formation of the ion [Cys-H]-, and dissociation of the CH2-SH bond, resulting in formation of the ion [SH]-. The presence of these ions suggests that both the p*(-CO2H) and *(C-S) orbitals can act as low energy electrophores on Cys. This ionization trend was observed for the dipeptides Cys-Gly and g-Glu-Cys as well as glutathione, with evidence that dissociation of the CH2-SH bond in these peptides can also result in ions of the form [M-SH...
We compare the predictions of four different algorithms for the distribution of ionized gas during the Epoch of Reionization. These algorithms are all used to run a 100 Mpc/h simulation of reionization with the same initial conditions. Two of the algorithms are state-of-the-art ray-tracing radiative transfer codes that use disparate methods to calculate the ionization history. The other two algorithms are fast but more approximate schemes based on iterative application of a smoothing filter to the underlying source and density fields. We compare these algorithms' resulting ionization and 21 cm fields using several different statistical measures. The two radiative transfer schemes are in excellent agreement with each other (with the cross-correlation coefficient of the ionization fields >0.8 for k 0.6 for k < 1 h/Mpc). When used to predict the 21cm power spectrum at different times during ...
We analyze spin correlations between top quark and anti-top quark produced at polarized e{sup +} e{sup -} and {gamma}{gamma} colliders. We consider a generic spin basis to find a strong spin correlation. Optimal spin decompositions for top quark pair are presented for e{sup +}e{sup -} and {gamma}{gamma} colliders. We show the cross- section in these bases and discuss the characteristics of results.
We present a scheme for three-party simultaneous quantum secure direct communication by using EPR pairs. In the scheme, three legitimate parties can simultaneously exchange their secret messages. It is also proved to be secure against the intercept-and-resend attack, the disturbance attack and the entangled-and-measure attack.
We used microarrays and a previously established linkage map to localize the genetic determinants of brain gene expression for a backcross family of lake whitefish species pairs (Coregonus sp.). Our...Full Text Available
The non-natural pyrido[2,3-d]pyrimidine nucleoside F, which pairs preferentially with guanine (G) and adenine (A) within double-helical DNA, recognizes with high selectivity AT base pairs within triple-helical...Full Text Available
The electron scattering form factor for excitation of the 1/sup +/ state of /sup 88/Sr at 3.486 MeV has been calculated in the quasiparticle random phase approximation (QRPA). The disagreement between the data and restricted shell-model calculations can be explained in terms of the pairing correlations introduced by the QRPA; no ..delta..-h admixtures are required.
The electron scattering form factor for excitation of the 1"+ state of "8"8Sr at 3.486 MeV has been calculated in the quasiparticle random phase approximation (QRPA). The disagreement between the data and restricted shell-model calculations can be explained in terms of the pairing correlations introduced by the QRPA; no #DELTA#-h admixtures are required. (orig.).
The point-defect-impurity pair diffusion model proposed recently by Mulvaney and Richardson is adopted and modified to simulate the coupled diffusion of phosphorus and self-interstitials in phosphorus-implanted silicon. The assumption of implantation-induced, but empirically determined initial interstitial distributions of Gaussian shape allows a simulation of the net effect of transient enhanced diffusion. As a result an improved modeling of phosphorus diffusion in silicon is achieved for a broad range of ion-implantation and annealing conditions. (author).
Given the spectrum of a Hamiltonian, a methodology is developed which employs the Landau-Ginsburg theory for characterizing phase transitions in infinite systems to identify phase transition remnants in finite fermion systems. As a first application of our approach we discuss pairing in finite nuclei. (orig.)
We study the signals for composite vector leptoquarks in e"+e- colliders (CERN e"+e- collider LEP II, Next Linear Collider, and CERN Linear Collider) through their effects on the production of jet pairs, as well as their single and pair productions. We also analyze their production in #gamma#e and #gamma##gamma# collisions.
Progress in four research areas on this project are summarized under the following topics: (1) Geminate charge pair recombination in hexane; (2) Fast current measurements resulting from excitation of charge transfer (CT) states; (3) Measurement of the dipole moment of excited states by DC conductivity; and (4) Charge separation at macroscopic interfaces between electron donor and acceptor solids. In a final section, personnel who have contributed to the project during the past budget period are described.
Laser-induced change is studied of the optical absorption and luminescence due to F-H pairs generated by an electron pulse in SrF_2. It is found that laser irradiation near 2.34 eV at a delay of 26 #mu#s after an electron pulse by which F-H pairs are generated reduces the component I of the pairs that has a decay time of 59 #mu#s and optical absorption bands at 2.34 and 4.13 eV and enhances the component II that has a decay time of 7.7 ms and has optical absorption bands at 2.7 and 3.35 eV. Laser irradiation near 2.7 eV at a delay of 4 ms after the electron pulse is found to induce the reverse reaction. Studies of dichroism of the laser-induced reduction and enhancement of the optical absorption bands and the luminescence reveal that the direction of the #SIGMA#-#SIGMA# transition of the F_2"- molecular ion is converted by the transformation from I to II and vice versa. It is suggested that the component I corresponds to ...
Proton and neutron transfer populating low-lying states have been studied in the system {sup 144}Sm+{sup 88}Sr at an energy below the Coulomb barrier. The experimental cross sections for the single proton transfer are well reproduced by DWBA-calculations using spectroscopic information from light ion reactions. The two-proton transfer appears enhanced relative to the uncorrelated sequential transfer of single protons. The same holds for the transfer of proton pairs, the enhancement is kept for the second pair. This is interpreted as a supercurrent between two superfluid nuclear proton-pair wave functions: More mass and charge is transported per time unit in pairs than by single nucleons. Neutron transfer is observed with large cross sections and is found to contribute to the energy loss observed in the transfer reactions. For mixed proton-neutron transfers the sequential nature of the transfer reactions ...
Proton and neutron transfer populating low-lying states have been studied in the system "1"4"4Sm+"8"8Sr at an energy below the Coulomb barrier. The experimental cross sections for the single proton transfer are well reproduced by DWBA-calculations using spectroscopic information from light ion reactions. The two-proton transfer appears enhanced relative to the uncorrelated sequential transfer of single protons. The same holds for the transfer of proton pairs, the enhancement is kept for the second pair. This is interpreted as a supercurrent between two superfluid nuclear proton-pair wave functions: More mass and charge is transported per time unit in pairs than by single nucleons. Neutron transfer is observed with large cross sections and is found to contribute to the energy loss observed in the transfer reactions. For mixed proton-neutron transfers the sequential nature of the transfer reactions is ...
The experimental survey about the heat transfer between the working fluid and the combustion chamber wall with a direct injection diesel engine has shown the production of a soot layer with increasing loads on the combustion chamber wall. Because the combustion process of methanol occurs without the formation of wall deposits, the same engine spark ignitioned with methanol at the same conditions has shown a higher heat transfer coefficient. Because the heat losses do not only depend on the heat transfer coefficient but also on the driving temperature difference between the working fluid and the combustion chamber wall, the methanol engine with corresponding process management showed lower heat losses than the diesel engine at nearly the same load. (orig./HW)
Based on the CFD-code FLUENT trademark, theoretical studies were conducted of the influences of incineration chamber geometry (direct, countercurrent and center flow) on the combustion process. The boundary conditions, e.g., the thermal input and the waste grate, were kept constant. Close attention was paid to the distribution of flow, spe-cies, and temperatures. In addition, the influence of a dis-placement body at the end of the combustion chamber was tested. The variation of different wall materials and the prediction of problem areas concerning corrosion, slagging, and contamination completed the studies. Close to the chamber walls, high CO-concentrations may indi-cate corrosion; particle flow may indicate where contami-nation, slagging or erosion could occur. (orig.)
This paper addresses the stability aspects of several successful dc superconducting magnets such as large bubble chamber magnets, and magnets for the Mirror Fusion Test Facility and MHD Research Facility. Specifically, it will cover Argonne National Laboratory 12-Foot Bubble Chamber magnets, the 15-foot Bubble Chamber magnets at Fermi National Laboratory, the MFTF-B Magnet System at Lawrence Livermore National Laboratory, the U-25B Bypass MHD Magnet, and the CFFF Superconducting MHD magnet built by Argonne National Laboratory. All of these magnets are cooled in pool-boiling mode. Magnet design is briefly reviewed. Discussed in detail are the adopted stability critera, analyses of stability and disturbance, stability simulation, and the final results of magnet performance and the observed coil disturbances.
This paper consists the radiation streaming analysis of Horizontal penetrations in Calandria Vault of 540 MWe PHWR. There are total 19 penetrations, penetrating east and west walls of calandria vault of 540 MWe PHWR. These penetrations are provided to accommodate ion chambers. HFUs and SDS - 2. Penetrations described here are not present in 220 MWe units except for ion chamber penetrations. As these penetrations are in accessible area, a detailed analysis has been carried out to find out the neutron and gamma dose rates around these penetrations when reactor is operating. Analysis has been carried out using computer code DOT-III and MCNP. Predictions by this method compare well with the measurements at ion chamber locations at KGS-1,2. (author)
An intake system is described for a direct fuel injection diesel engine having a cylinder block, at least one cylinder in the cylinder block, a piston in the cylinder having a recess on a top surface thereof, a cylinder head mounted on the cylinder block on top of the cylinder, a fuel injector adapted to directly inject fuel into a combustion chamber formed between the lower side of the cylinder head and the recess on the top surface of the piston, and below the injector, and a single exhaust passage opening to the combustion chamber at a location near the injector, the intake system comprising first and second intake passages in the cylinder head, the first and second intake passages are independent of each other and adapted to introduce air into the combustion chamber. The controller means are coupled to the second intake passage for controlling the flow of air therethrough.
Flame propagating through zirconium particle cloud in a small-scale vertical rectangle chamber was investigated experimentally. In the experiments, the zirconium quoted 99% purity was used and the diameter of particles was distributed 1?22 ?m. The zirconium dust was dispersed into the chamber by air flow and ignited by an electrode spark. A high-speed video camera was used to record the images of the propagating flame. Micro-thermocouples, schlieren optical system and microscopic lens were used to obtain temperature profiles and flame structure, respectively. Based on the experimental results, flame propagation characteristics and flame structure of zirconium particle cloud were analyzed. The propagation velocity of the flame is quite slow in the initial 14 ms and then accelerates to maxim...
An apparatus for non-invasively inspecting an object, such as an item of luggage, for explosives material is described. It comprises a multi-channel thermal neutron inspection system having a plurality of neutron irradiation chambers. Simultaneous operation of several channels increases the maximum system throughput several times. Each chamber has a lithium neutron source which is stimulated to neutron production by a proton beam. Beam switching magnets are energised by pulsing to divert a common proton beam to each source in turn. The initial beam is generated by a radio frequency quadrupole accelerator. The advantages of this system are very low residual source activity and controllable neutron production thereby minimising safety hazards. The irradiation chamber may contain several different gamma ray detectors to identify the elements present in explosives material. In addition, a neutron radiography imaging means may ...
The unburned HC in a direct-injection diesel engine is a cause of exhaust odor and SOF emission. Reduction of HC by changing the injection nozzle specifications was attempted in previous studies. In this study, some experiments in which the mixture formation was varied by using different hole diameters in a multihole nozzle and spray angles to the combustion chamber wall have been conducted. When the diameter of injection holes, which influences the fuel adhering to on the cylinder head walls and the combustion chamber wall, becomes smaller, the HC emission in the idling condition, HC deviation from cylinder to cylinder and HC increase with long idling time are decreased. The same effects were obtained by decreasing the diameter of all holes and by injecting the spray downward to the combustion chamber. 13 refs., 13 figs., 1 tab.
In an attempt to overcome inadequacies perceived in the approach to providing energy to village communities using the conventional Khadi and Village Industries Commission biogas plant as well as the Janata model, a biogas digester has been developed suitable for a farmer having only one hectare of land. The information on gas yields and other data from a variety of substrates in a laboratory digester are presented. The digester itself consists of a chamber underground into which the influent flows through a channel. Gas is collected in a dome which constitutes the upper part of the digestion chamber and is maintained under pressure by water. The dome can be made of any suitable material such as plastic, ferrocement and brick and mortar. The upper part of the chamber itself is exposed to sun light which enhances microbial growth. Water which surrounds the dome ensures a minimum of temperature variation. 3 references.
Several proposals have been made on the method of calculating generation of formaldehyde released from plywood. In calculating generation per hour of a volatile organic compound of adhesives or coatings using a chamber method, such models are frequently used that the generation is largest when the specimen is exposed in the chamber and that the generation attenuates with lapse of time. In the meantime, a number of studies for calculating formaldehyde generation from construction materials are often those determining a specific quantity of generation in a stationary state, while few studies are the observation of time series variation from immediately after the exposure into the chamber. Accordingly, the subject studies used lauan plywood as the samples and examined the method of calculating the change with lapse of time of the formaldehyde generation. (translated by NEDO)
2000-003 Wire pad chambers (WPC) have been proposed for the outer Region 4 of the LHCb Muon System. These are double gap MWPCs with small wire spacing allowing to obtain 99% detection efficiency in a 20 ns time window. The chambers have a rectangular shape with the vertical dimension from 20 cm in Station 1 to 30 cm in Station 5. The horizontal dimensions will be different with the maximal size of 3 meters in Station 5. The wires are in the vertical direction. The short wire length allows to use small wire spacing needed for high time resolution. Also, this helps to obtain the uniform gas gain over the whole chamber area. The WPC has one row of the wire pads formed by grouping wires in separate readout channels. Four WPC prototypes have been built at PNPI and tested in the PS beam at CERN. Here we report on the results from these tests. Also, the results of simulation of the WPC performance are presented.
Simplifying hypotheses are required when combustion and aerodynamic phenomena are considered simultaneously. In this paper, a turbulent combustion model is proposed, in which the combustion chemistry is reduced to a single reaction. In this way, only two variables are needed to describe the problem and combustion can be characterized by the consumption of one of the two reactive species. In a first step, the instantaneous consumption rate is obtained using the Lagrangian form of the mass fraction equation of the species under consideration, and by considering the equilibrium state only. This state is determined in order to preserve the consistency with results that should be obtained using a complete kinetics scheme. In a second step, the average rate is determined using the instantaneous consumption term and a probabilistic density function. This model was tested on various configurations and in particular on an experimental main chamber and on a reheating ...
Processes and apparatus are disclosed for generation of radioisotope contaminant fission fragment free ozone from oxygen containing streams by chemonuclear irradiation accomplished by passing the stream past high energy radiation sources placed in sealed chambers.
Mouse models for the study of autistic-like behaviors are increasingly needed to test hypotheses about the causes of autism, and to evaluate potential treatments. Both the automated 3-chambered...Full Text Available
An investigation was conducted to determine the cause of coating residue found in the test gun chambers during qualification firing of 120-mm combustible cartridge case (CCC) ammunition for the MlAl/A2 main battle tank. The CCC is coated with a clear epox...
To carry out studies on the radon behavior under controlled and stable conditions it was designed and constructed a system that consists of two parts: a container of mineral rich in Uranium and an experimentation chamber with radon united one to the other one by a step valve. The container of uranium mineral approximately contains 800 gr of uranium with a law of 0.28%; the radon gas emanated by the mineral is contained tightly by the container. When the valve opens up the radon gas it spreads to the radon experimental chamber; this contains 3 accesses that allow to install different types of detectors. The versatility of the system is exemplified with two experiments: 1. With the radon experimental chamber and an associated spectroscopic system, the radon and two of its decay products are identified. 2. The design of the system allows to couple the mineral container to other experimental geometries to demonstrate this fact ...
BackgroundWith the phasing out of ozone-depleting substances in accordance with the United Nations Montreal Protocol, phosphine remains as the only economically viable fumigant for...Full Text Available
This patent describes in an dual gas-liquid fuel four cycle engine having cylinders and wherein each cylinder is operatively connected thereto and each cylinder has a piston, two inlet valves, two exhaust valves and a first liquid fuel injector. It comprises: at least one fuel torch cell operatively connected to at least one cylinder, the torch cell having a torch cell nozzle at one end thereof and the other end having appropriate means to connect the torch cell to a fuel supply, a second fuel injector mounted in the torch cell at a predetermined angle to an axis of the torch cell, the torch cell defining an auto-ignition chamber, the second fuel injector being in operative communication with the auto-ignition chamber by an injector nozzle passageway, the injector nozzle passageway entering the auto-ignition chamber at a predetermined angle relative to the axis, and a torch nozzle passage connecting the auto-ignition ...
Abstract in english In this work the air flow in a furnace was computationally investigated. The furnace, for which experimental test data are available, is composed of a movable block burner connected to a cylindrical combustion chamber by a conical quarl. The apertures between the movable and the fixed blocks of the burner determine the ratio of the tangential to the radial air streams supplied to the furnace. Three different positions of the movable blocks were studied at this time. A thr (more) ee-dimensional investigation was performed by means of the finite volume method. The numerical grid was developed by the multiblock technique. The turbulence phenomenon was addressed by the RNG k-epsilon model. Profiles of the axial, tangential and radial velocities in the combustion chamber were outlined. The map of the predicted axial velocity in the combustion chamber was compared with a map of the experimental axial velocity. ...
We have demonstrated that, with simple pH adjustment, volatile drugs such as methamphetamine, amphetamine, 3,4-methylenedioxymethamphetamine (MDMA), ketamine, and valproic acid could be analyzed rapidly from raw biofluid samples (e.g. urine and serum) without dilution, or extraction, using atmospheric pressure ionization. The ion source was a variant type of atmospheric pressure chemical ionization (APCI) that used a dielectric barrier discharge (DBD) to generate the metastable helium gas and reagent ions. The sample solution was loaded in a disposable glass pipette, and the volatile compounds were purged by nitrogen gas to be reacted with the metastable helium gas. The electrodes of the DBD were arranged in such a way that the generated glow discharge was confined within the discharge tub...
A high-precision Li isotope analysis was developed for determining the Li"+ ion emitted from lithium phosphate as an ion source material by a Re double-filament ionization method in the thermal ionization mass spectrometry. In this method, Li isotopic fractionation is distinctly less sensitive to the filament temperature than those in the previous methods, and stable and high ion beam intensity of more than 8 x 10"-"1"1 A for "7Li is obtained. These advantages in determining the "7Li/"6Li ratio result in the analytical reproducibility of 0.26 per mille (1#sigma#). Furthermore, the sample preparation is simple and the low temperature (850degC) required by this method ensures the analysis of the isotopic composition of small amounts of Li with less influence of Li contamination to the sample, compared with the previous methods. (author).
Photoelectron resonance capture ionization (PERCI) mass spectrometry has been developed for the direct online analysis of organics, including lipids. Analysis is conducted without the need for sample preparation or chemical derivatization such as methylation, foregoing the use of harmful or toxic chemicals. PERCI is currently being adapted towards the analysis of edible oils. Herein, as a proof of principle of the simplicity and potential utility of this method towards the analysis of edible oils, we present the analysis of the prevalent fatty acids (FA) in Tuscan extra-virgin olive oil along with triolein and linolenic acid (LNA) standards. Ionization of olive oil results in little fragmentation of the prevalent FA, which are measured as their molecular ions, [FA-H]-. The relative concent...
A crossed-electron-ion-beam experiment was used to measure the total ionization cross section for Ar"8"+ in the energy range from 50 to 600 eV. The present results are roughly in agreement with the previous measurements of Defrance et al. [Nucl. Instrum. Methods Phys. Res. B 23, 256 (1987)] above 450 eV. However, the present measurements show a significant contribution below the threshold for direct ionization. The present measurements agree with the distorted-wave calculations of Pindzola et al. [Phys. Rev. A 41, 1375 (1990)] when 3% of the incident ion beam is assumed to be in metastable states and excitation autoionization from metastable states is included.
Abstract We use Smoothed Particle Hydrodynamics to simulate the formation of a massive (106-M-) stellar cluster system formed from the gravitational collapse of a turbulent molecular cloud. We investigate the hierarchical clustering properties of our model system and we study the influence of the photoionizing radiation produced by the system's multiple O-type stars on the evolution of the protocluster. We find that dense gas near the ionizing sources prevents the radiation from eroding the filaments in which most of the star formation occurs and that instead, ionized gas fills pre-existing voids and bubbles originally created by the turbulent velocity field.
Thick targets of several heavy lanthanide (Ho-Lu) compounds were bombarded by protons and "3He ions of 3 MeV/amu, and M_#alpha# and M_#beta# X-rays were measured with a crystal spectrometer. Ionization probabilities of the N-shell for zero impact parameter were obtained from the X-ray intensity ratio for proton and "3He ion impacts. A shell dependence of the ionization probability was found in a scaling plot. X-ray spectra of lanthanide compounds were compared and no chemical effect was observed. This result is considered to be due to the fact that the main component of M_#alpha# and M_#beta# lines is for radiative transition after the refilling of the 4f orbit (3d"-"14f"n"+"1 #-># 4f"n) where n denotes the number of 4f electrons of the target atom before ionization. (orig.).
High molecular weight products of the ozonolysis reaction of particle-phase 9-octadecenoic acid (oleic acid) have been studied by photoelectron resonance capture ionization (PERCI) mass spectrometry (MS). Oleic acid particles ( Formula Not Shown , Formula Not Shown ) were reacted with ozone (1.8x10-4atm) in a flow reactor at reaction times of 8 and 23s. Particles were sampled on-line with a differentially pumped particle inlet and chemically analyzed by PERCI-MS. PERCI is a soft ionization method that permits the direct measurement of relatively high molecular weight compounds, facilitating molecular identification. In addition to cyclic oxygenates, such as secondary ozonides and geminal diperoxides that were reported previously, we demonstrate the formation of polymers at the particle sur...
The proton and deuteron spectra following resonant multiphoton ionization of H{sub 2} and HD at 193 nm through the {ital E},{ital F} state have been studied at power densities of 10{sup 10} W/cm{sup 2}. Our results show that the intermediate state induces competition between 3(2+1)-photon ionization, dissociation, and dissociative ionization channels. We find that the competition depends on the specific vibrational and rotational levels excited in the intermediate state. At the same time, the mere presence of this bound intermediate state renders these three-photon fragmentation channels so efficient that higher-order fragmentation processes, such as Coulomb explosions requiring many more photons, are not observed.
A means of determination of a ctive hydrogen of hydroxyl, carboxyl, sulfhydryl, amino, amido and sulfonamido groups by chemical ionization mass spectrometry using ammonia and trideuterioammonia as reagent gases is described. The method is based on exchange of active hydrogen for deuterium occurring during the chemical ionization process using trideuterioammonia, with comparison of m/z for ammonium adduct [M + NH1]+ and trideuterioammonium adduct [M--nH + nD + ND4]+, or of protonated molecular ion [M + H]+ and deuteronated molecular ion [M--nH + nD + D]+ yielding the number of active hydrogens. Applications have been made to several classes of biologically important compounds. PMID:427257
High-pressure waterjet equipment is now technically and economically viable and commercially available for the following mining and construction applications: (1) drilling soft to medium-hard rock; (2) slotting, discing, chambering, and reaming in all types of rock. However, additional field experience is needed to prepare detailed economic evaluations. Extensive development of new explosives techniques and blasting methods will be required to take full advantage of the unique waterjet hole slotting, discing, and chambering capabilities.
Discusses design of unconventional pneumatic forms for construction of monolithic liners in mine roadways driven by drilling and blasting. The forms were developed for construction of the municipal subway in Leningrad. They were successfully tested in the Pavlogradugol' mines for construction of chambers situated at shaft bottom at depths of 420 m. The chambers were situated in unstable rock strata. A set of pneumatic forms consisted of 4 to 7 units, each 0.4 m thick and 1.2-2.2 m long. Air pressure was 0.03 MPa, installation time was about 20 min. Service life of pneumatic forms ranged from 3 to 4 years.
Objective: Optimization and testing of a high temperature combustion chamber for burning coal gas and conventional fuels natural gas or fuel oil. Coal gas is not available in such quantity for testing a full scaled combustion chamber. Therefore the design of the combustion chamber is based of experimental results from model tests and numerical solution procedures. Working program: (1) Analytical model for burning coal gas implemented in an existing computational fluid dynamics (CFD) code. (2) Three-dimensional calculations of a full scaled combustion chamber with a CFD code for flows accompanied by combustion and chemical reaction. (3) Improvement of measuring method for determination of flame temperature and concentration. (4) Temperature and concentration profil measuring in a full scaled combustion chamber by operating with natural gas or fuel oil. Results: An analytical model ...
Apparatus and a method of introducing a primary fuel, which may be a coal water slurry, and a high combustion auxiliary fuel, which may be a conventional diesel oil, into an internal combustion diesel engine comprises detecting the load conditions of the engine, determining the amount of time prior to the top dead center position of the piston to inject the main fuel into the combustion chamber, and determining the relationship of the timing of the injection of the auxiliary fuel into the combustion chamber to achieve a predetermined specific fuel consumption, a predetermined combustion efficiency, and a predetermined peak cylinder firing pressure. 19 figures.
An LPP ignition timing control is described for an internal combustion engine including a combustion chamber, means effective to ignite a combustible charge within the combustion chamber and power output apparatus including a rotating crankshaft driven in response to the expansion of the combustible charge following the ignition thereof and having a predefined TDC rotational reference position, the engine being of the type having a normal combustion mode characterized by combustion pressure peaks compatible with closed loop LPP ignition timing control and an abnormal combustion mode which may not be so compatible.
Absolute fission rate measurements using modified National Bureau of Standards fission chambers were performed in the Fast Flux Test Facility at two core locations for isotopic deposits of {sup 232}Th, {sup 233}U, {sup 235}U, {sup 238}U, {sup 237}Np, {sup 239}Pu, {sup 240}Pu, and {sup 241}Pu. Monitor chamber results at a third location were analyzed to support other experiments involving passive dosimeter fission rate determinations.
Absolute fission rate measurements using modified National Bureau of Standards fission chambers were performed in the Fast Flux Test Facility at two core locations for isotopic deposits of {sup 232}Th, {sup 233}U, {sup 235}U, {sup 238}U, {sup 237}Np, {sup 239}Pu, {sup 240}Pu, and {sup 241}Pu. Monitor chamber results at a third location were analyzed to support other experiments involving passive dosimeter fission rate determinations.
A large scintillation chamber of 6.7 l volume for direct radon concentration measurements in gas is presented. With two 5 in. photomultipliers on opposite sides, working in coincidence, a concentration as low as about 0.5 mBq/l is detectable with 10% standard deviation after 1000 min measuring time. With the achieved background count rate of 0.42 counts/min and the counting efficiency of 0.607 for [sup 222]Rn and its progenies the absolute minimal detectable specific activity is reached with 0.17 mBq/l at about 12 000 min. The method to determine this minimum detectable activity is outlined. ((orig.))
Full text: Introduction. Children, especially premature infants and neonates, are at a much higher risk to obtain an X ray induced disturbance of life - particularly cancer. On the one hand this is due to their longer life expectancy and on the other hand it is due to their higher cell proliferation rate. The paediatric radiology unit of the Inselspital Bern recently installed some of the most advanced X ray equipment nowadays available. It is based on the two latest digital technologies: double read computed radiography (CR) and direct digital radiography (DR). Only the implementation of these digital radiography systems permits the digital acquisition and additionally the analysis of acquired data. The systematic analysis of large amounts of biometric data and exposition data is the basis for further dose reduction and a systematic quality control (QC). Patients are increasingly critical concerning radiation exposure - especially parents regarding their children. Besides an ...
We propose a quantum secure direct communication scheme based on non-orthogonal entangled pairs and local measurement. In this scheme, we use eight non-orthogonal entangled pairs to act as quantum channels. Due to the non-orthogonality of the quantum channels, the present protocol can availably prohibit from all kinds of valid eavesdropping and acquire a secure quantum channel. By local measurement, the sender acquires a secret random sequence. The process of encoding on the random sequence is identical to the one in one-time-pad. So the present protocol is secure. Even for a highly lossy channel, our scheme is also valid. The scheme is feasible with present-day techniques.
We present a quantum secure direct communication scheme achieved by swapping quantum entanglement. In this scheme a set of ordered Einstein-Podolsky-Rosen (EPR) pairs is used as a quantum information channel for sending secret messages directly. After insuring the safety of the quantum channel, the sender Alice encodes the secret messages directly by applying a series local operations on her particle sequences according to their stipulation. Using three EPR pairs, three bits of secret classical information can be faithfully transmitted from Alice to remote Bob without revealing any information to a potential eavesdropper. By both Alice and Bob's GHZ state measurement results, Bob is able to read out the encoded secret messages directly. The protocol is completely secure if perfect quantum channel is used, because there is not a transmission of the qubits carrying the secret message between Alice and Bob in the public channel.
I describe a search for anomalous production of Z pairs through a new massive resonance X in 2.5-2.9 fb{sup -1} of p{bar p} collisions at {radical}s = 1.96 TeV using the CDFII Detector at the Fermilab Tevatron. I reconstruct Z pairs through their decays to electrons, muons, and quarks. To achieve perhaps the most efficient lepton reconstruction ever used at CDF, I apply a thorough understanding of the detector and new reconstruction software heavily revised for this purpose. In particular, I have designed and employ new general-purpose algorithms for tracking at large {eta} in order to increase muon acceptance. Upon analyzing the unblinded signal samples, I observe no X {yields} ZZ candidates and set upper limits on the production cross section using a Kaluza-Klein graviton-like acceptance.
Methylation of the DNA bases in the Watson-Crick GC and AT base pairs by the methyldiazonium ion was investigated employing density functional and second order Moller-Plesset (MP2) perturbation theories. Methylation at the N3, N7 and O6 sites of guanine, N1, N3 and N7 sites of adenine, O2 and N3 sites of cytosine and the O2 and O4 sites of thymine were considered. The computed reactivities for methylation follow the order N7(guanine)>N3(adenine)>O6(guanine) which is in agreement with experiment. The base pairing in DNA is found to play a significant role with regard to reactivities of the different sites.
Various characteristics of F stars are described. The spectra of F stars are analyzed, and it is determined that the spectral types are based on ionization levels. The CNO cycle and rotation speeds of the stars are examined. The period-luminosity relation of pulsators is studied, and specific examples of unstable pulsators are presented.
To capitalize on the response of tumor cells to ionizing radiation, we developed a controlled-release nanoparticle drug delivery system using a targeting peptide that recognizes a radiation-induced...Full Text Available
A fast and sensitive LC-ESI-MS method is described for the comparative quantification of 16 estrogen metabolites based on the derivatization of estrogens with a novel derivatizing reagent, N-methyl-nicotinic...Full Text Available
Spectral line intensity data are presented for ionized hydrogen regions in the giant spiral galaxy M101. The influence of interstellar extinction is assessed and electron temperatures of the gas clouds are derived.
Numerical simulations predict that a large number of baryons reside in intergalactic space at temperatures between 10^5-10^7 K. Highly-ionized metals, such as O VII and O VIII, are good tracers of this ``warm-hot intergalactic medium'', or WHIM. For collisionally-ionized gas, the ionization fraction of each ion peaks at some particular temperature (``peak temperatures''), so different ions can therefore trace the IGM at different temperatures. We performed a hydrodynamic simulation to study the metal distributions in the IGM. We then draw random lines-of-sight across the simulated region and synthesize resonance absorption line spectra in a similar way to simulating the Ly-alpha forest. By studying the distribution functions of H- and He-like O, Si and Fe in a collisionally-ionized IGM and comparing with semi-analytic results based on the Press-Schechter formalism, we find: (1) ions with higher peak ...
AbstractBackgroundIonizing radiation (IR) initiates intracellular oxidative stress through enhanced formation of reactive oxygen species (ROS) that attack DNA leading...Full Text Available
We report the first quantitative assessment of electrosprayed droplet/ion focusing enabled by the use of a voltage-assisted air amplifier between an electrospray ionization emitter and a hybrid...Full Text Available
Cancer treatment with ionizing radiation is often compromised by organ motion, in particular for lung cases. Motion uncertainties can significantly degrade an otherwise optimized treatment plan....Full Text Available
Our goal was to determine whether chlorpyrifos oxon, dichlorvos, diisopropylfluorophosphate (DFP), and sarin covalently bind to human albumin. Human albumin or plasma was treated with organophosphorus...Full Text Available
BackgroundDNA repair is the general term for the collection of critical mechanisms which repair many forms of DNA damage such as methylation or ionizing radiation. DNA repair has...Full Text Available
DNA double-strand breaks (DSBs) are generally accepted to be the most biologically significant lesion by which ionizing radiation causes cancer and hereditary disease. However, no information on the...Full Text Available
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MS) has been explored widely for DNA sequencing. The major requirement for this method is that the DNA sequencing fragments...Full Text Available
A compensatory response, viz. in vivo recovery from radiation damage to mitochondria, occurs in preclimacteric pear fruits (Pyrus communis L.) treated with ionizing...Full Text Available
The work scope of 'Biological Research for the Radiation Protection' had contained the research about ornithine decarboxylase and its controlling proteins, thioredoxin, peroxiredoxin, S-adenosymethionine decarboxylase, and glutamate decarboxylase 67KD effect on the cell death triggered ionizing radiation and H_2O_2(toxic agents). In this study, to elucidate the role of these proteins in the ionizing radiation (or H_2O_2)-induced apoptotic cell death, we utilized sensesed (or antisensed) cells, which overexpress (or down-regulate) RNAs associated with these proteins biosynthesis, and investigated the effects of these genes on the cytotoxicity caused by ionizing radiation and H_2O_2(or paraquat). We also investigated whether genisteine(or thiamine) may enhance the cytotoxic efficacy of tumor cells caused by ionizing radiation (may enhance the preventing effect radiation or paraquat-induced damage) because ...
MRI plays an increasingly important role for assessment of patients with chronic liver disease. MRI has numerous advantages, including lack of ionizing radiation and the possibility of performing...Full Text Available
The document published under A/63:46 and titled report of the scientific committee of United Nations for the study of ionizing radiations effects, gives the situation of the fifty sixth session of the committee that stood at Vienna from the 10. to 18. july 2008. In the chapter 3 of this report the writers summarize the strategic planning and the working program of the scientific committee for the period 2009-2013. They note that the committee worry about the inadequate means, particularly in personnel. The priorities for the given period will be the medical exposure of patients, the radiation levels and the effects of energy production, the exposure to natural radiation sources and the improvement of the understanding of the effects of the low doses radiation exposure. (N.C.)
The aim of this paper is to investigate the total ionizing dose (TID) radiation effects on MOS capacitor with nitride/oxide stack gate. The stack gate MOS capacitors are fabricated with 20 nm oxide, 40 nm nitride or 110 nm nitride respectively. Through the analysis of CV curve of the irradiation capacitors, it is found that the degradation of the CV curve is due to a significant increase of interface traps and somewhat smaller oxide charge. It is also shown that the thicker of the nitride, more interface traps and oxide charge will be occurred. (authors)
The results of theoretical and experimental investigations, describing the effect of ionizing radiation on wood and its main components and methods for production of wood-plastic composites by means of radiation-induced chemical modification are generalized. Domestic and foreign experience in their production is systematized; physico-mechanical characteristics of new material, simulation and calculation of irradiating devices, as well as calculation and experimental study of #gamma#-radiation attenuation both by wood material and by wood of different species are given. Gamma sources ("6"0Co isotope, a hot loop of a nuclear reactor) as well as electron accelerators are considered as ionizing radiation sources.
We have constructed an apparatus to study electron impact ionization of ions which should provide additional insight into the mechanisms involved. Using multiparameter coincidence techniques, we will detect both outgoing electrons from ionization process and will be able to analyze the momenta of both particles simultaneously. Coupled with a high resolution electron gun, this information should have broad application to the difficult problem of three bodies interacting via the long range Coulomb force. If sufficient accuracy can be achieved, information regarding the relative phase of the outgoing electron wavefunctions can be obtained.
The combined magnetic braking-ambipolar diffusion problem in weakly ionized, rigidly rotating disks is studied. An analytical solution is presented for a disk whose angular velocity and magnetic yield vectors are aligned with the symmetry axis, illustrating the effects of the relative azimuthal drift of neutrals and ions. The effects of radial drift are added, commenting on the ratio of the characteristic ambipolar diffusion and magnetic braking time scales in high-mass and low-mass disks. A numerical calculation is used to show the combined action of these two processes. 31 references.
The procedure of charge-coupled devices (CCD) are investigated by using MOS capacitors for enhancing their ionizing radiation tolerance. Authors have found that the gate oxidation temperature, thickness of SiO_2 gate insulator and high temperature processes after gate oxidation are crucial for determining the radiation tolerance of the devices, and proposed to decrease the thickness of gate insulator, perform gate oxidation at 1000 deg C by means of dry oxidation and minimize the number of high temperature procedure steps after gate oxidation. All stated above is a necessary preparation for priducing radiation hardened charge-coupled devices.
The objectives of the research in the field of epidemiology , performed at the Belgian Nuclear Research Centre SCK-CEN are (1) to study cancer mortality and morbidity in nuclear workers in Belgium; (2) to document the feasibility of retrospective cohort studies in Belgium; (3) to participate in the IARC study. For radiobiology, the main objectives are: (1) to elucidate the mechanisms of the effects of ionizing radiation on the mammalian embryo during the early phase of its development, (2) to assess the genetic risks of maternal exposure to ionizing radiation, (3) to elucidate the mechanisms by which damage to the brain and mental retardation are caused in man after prenatal irradiation. The main achievements in these domains for 1997 are presented.
Hitherto in this laboratory, ionization coefficients alpha and attachment coefficients #eta# have been determined from Townsend's discharge experiments by a curve-fitting method. However, the method proved to be laborious, Formulae have been derived in this paper to give value of alpha and #eta# as a function of Isubo, Isub1 and Isub2 where Isubo is the photoelectric current at a gap setting d and Isub2 the current at another gap setting 2 d. The values of alpha and #eta# obtained give currents in agreement to within 3% in the best cases with the observed currents.
Neutral atom beams with energies above 200 keV may be required for various purposes in magnetic fusion devices following TFTR, JET and MFTF-B. These beams can be produced much more efficiently by electron detachment from negative ion beams than by electron capture by positive ions. We have investigated the efficiency with which such neutral atoms can be produced by electron detachment in partially ionized hydrogen plasma neutralizers.
Atomic L- and M-shell ionization cross sections by protons have been calculated in the plane-wave Born approximation for /sub 79/Au and /sub 92/U with incident energy from 0.1 to 3 MeV with use of relativistic and nonrelativistic Hartree-Slater wave functions. These results are compared with those from the screened hydrogenic model to study the effects of relativity and wave functions. The relativistic and wave-function effects are found to operate in opposite directions. For M/sub 1,2,3/-subshell cross sections, severe cancellations occur between these two factors.
The authors investigated the influence of tartaric acid, which possesses complex-forming properties. In order to establish the optimum system of possible refinement of tellurium, the authors study the kinetics of both the cathodic and the anodic processes. The investigation of processes of discharging-ionization of tellurium from nitric acid electrolytes in the presence of tartrate ions showed the possibility of preparing a nitric-tartaric acid electrolyte which can be used for commercial purposes and from which a high-purity raffinate was obtained from technical tellurium.
This work presents a study of the {sup 1}P{sup 0} excited states of He that can be reached by absorption of a single photon carrying an energy close to the double ionization threshold (DIT) (79 eV). Above the DIT, these states are the double continuum states; below, they are the double excited states. These two types of states are tightly coupled to the single continuum states with or without excitation of the residual ion He{sup +}, owing to their degeneracy in energy. In a one-photon process, these states can only be formed owing to the electronic correlations in the system which must be well described to obtain quantitative good results. Our study is a part of the work which aims at a united description of all these doubly excited, ionized-excited, and double continuum states. We use the Hyperspherical R-Matrix with Semiclassical Outgoing Waves (HRM-SOW) method, initially dedicated to double photoionization studies. We extend it to extract ...
Humans are quite unusual compared to other great apes in that reproduction typically takes place within long-term, iteroparous pairings—social arrangements that have been culturally reified...Full Text Available
We report a whole-genome shotgun assembly (called WGSA) of the human genome generated at Celera in 2001. The Celera-generated shotgun data set consisted of 27 million sequencing reads organized in pairs...Full Text Available
Computational methods for determining the secondary structure of RNA sequences from given alignments are currently either based on thermodynamic folding, compensatory base pair substitutions or both....Full Text Available
The genes which encode glycosomal glyceraldehyde-phosphate dehydrogenase (gGAPDH) of Trypanosoma cruzi are arranged as a tandemly repeated pair on a single chromosome and are identical at the level...Full Text Available
This talk summarizes recent progress in top quark physics studies for high energy linear electron-positron colliders as presented at the LCWS2000 Workshop at Fermilab. New results were presented for top pair production at threshold and in the continuum, as well as for top production at #gamma##gamma# colliders.
Some extensions of the Standard Model often predict a Z'gauge boson which mediates flavor-changing neutral-current (FCNC) interaction between up and top quarks. These new physics models are phenomenologically attractive because they can explain the top quark forward-backward asymmetry $A^t_FB$ measured recently by the Tevatron collider. In addition, they will induce the top quark FCNC decays and the like-sign top pair production which can be explored at the LHC. In this work we focus on two such models (the left-right model and the $U(1)_X$ model) to investigate their correlated effects on $A^t_FB$, the FCNC decays $t -> u V (V=g,Z,\\gamma)$ and the like-sign top pair production at the LHC. We also pay special attention on the most recently measured $A^t_FB$ in the large invariant mass region. We find that under the current experimental constrains both models can alleviate the deviation of $A^t_FB$ and, meanwhile, enhance some FCNC decays ...
The C-C chemokine receptor 5, 32 base-pair deletion (CCR5-Δ32) allele confers strong resistance to infection by the AIDS virus HIV. Previous studies have suggested...Full Text Available
Purpose.Since 2002, six blind patients have undergone implantation of an epiretinal 4 × 4 electrode array designed to directly stimulate the remaining cells of the retina...Full Text Available
Superconductivity in A-15 compounds is examined in terms of electron pairing induced by exchange of acoustic plasmons. The electronic band structure of Nb_3Sn, V_3Si, and similar materials favor transition temperatures of Tsub(c)approximately20 K. (Auth.).
Digestion of plant chromatin from Brassica pekinensis and Matthiola incana with staphylococcus nuclease leads to a DNA repeat of 175 plus or minus 8 and a core size of 140 base pairs. DNase I digestion...Full Text Available
THEMIS-A: The Solid State Telescope (SST) measures the incoming intensity ... units (heads), each SST unit has two pairs of opposing ion and electron sensors. .... The five small satellites were launched together on a Delta II rocket and they ...
The sequence information available for homeodomains reveals that salt bridges connecting pairs 19/30, 31/42, and 17/52 are frequent, whereas aliphatic residues at these sites are rare and mainly restricted...Full Text Available
The T-loop motif is an important recurrent RNA structural building block consisting of a U-turn sub-motif and a UA trans Watson–Crick/Hoogsteen base pair. In the presence of...Full Text Available
We investigate the effects of single-particle structure and pairing on the equilibration of positive and negative-parity level densities for the even-even nuclei "5"8","6"2","6"6Fe and "5"8Ni and the odd-A nuclei "5"9Ni and "6"5Fe. Calculations are performed using the shell model Monte Carlo method in the complete fp-gds shell-model space using a pairing+quadrupole type residual interaction. We find for the even-even nuclei that the positive-parity states dominate at low excitation energies due to strong pairing correlations. At excitation energies at which pairs are broken, single-particle structure of these nuclei is seen to play the decisive role for the energy dependence of the ratio of negative-to-positive parity level densities. We also find that equilibration energies are noticeably lower for the odd-A nuclei "5"9Ni and "6"5Fe than for the neighboring even-even nuclei "5"8Ni and "6"6Fe.
We report the use of cysteine-substituted mutants in conjunction with in situ oxidation to determine the physical proximity of a pair of engineered cysteines in the pore region of the voltage-gated...Full Text Available
Evidence is presented for a distinctive type of hippocampal synaptic modification [previously described for a molluscan gamma-aminobutyric acid (GABA) synapse after paired pre- and postsynaptic excitation]:...Full Text Available
Activation-induced cytidine deaminase (AID) protein initiates Ig gene mutation by deaminating cytosines, converting them into uracils. Excision of AID-induced uracils by uracil-N-glycosylase...Full Text Available
Sep 9, 2009... a French Ariane rocket successfully launched a new Earth-observing satellite ... The payload is a pair of identical sensors known as "high-resolution ... the resulting image) are activated simultaneously by incoming radiation; ...
Alcohol dependence (AD) is clinically and etiologically heterogeneous. The goal of this study was to explore AD subtypes among a sample of 1, 221 participants in the Irish Affected Sib Pair...Full Text Available
The effect of feedback and materials on perceptual learning was examined in normal hearing listeners exposed to cochlear implant simulations. Generalization was most robust when feedback paired...Full Text Available
BackgroundGene duplication is the primary force of new gene evolution. Deciphering whether a pair of duplicated genes has evolved divergent functions is often challenging. The zebrafish...Full Text Available
Despite their structural resemblance, a pair of cyclic halogenated compounds, 1-chloro-1,2,2-trifluorocyclobutane (F3) and 1,2-dichlorohexafluorocyclobutane (F6), exhibit completely different anesthetic...Full Text Available
PCR was used with the primer pair VANS1-NS21 to detect the arbuscular mycorrhizal fungus Glomus intraradices (commercial inoculum source) on roots of lettuce, zinnia, leek, pepper, and endive plants....Full Text Available
A sensitive assay based on the polymerase chain reaction for the detection of Ockelbo virus RNA was developed. Two primer pairs from the gene coding for the E2 glycoprotein were chosen. By use of a...Full Text Available
Competent Haemophilus cells recognize and preferentially take up Haemophilus DNA during genetic transformation. This preferential uptake is correlated with the presence on incoming DNA of an 11-base-pair...Full Text Available
An RNA secondary structure is locally optimal if there is no lower energy structure that can be obtained by the addition or removal of a single base pair, where energy is defined according...Full Text Available
The cellular properties of long-term potentiation (LTP) following pairing of pre- and postsynaptic activity were examined at a known glutamatergic synapse in the leech, specifically between the pressure...Full Text Available
1. Paired or single recordings of paraventricular and/or supraoptic oxytocin cells at the beginning of suckling in urethane-anaesthetized rats enabled us to study cell recruitment and compare the characteristics...Full Text Available
Recent evidence suggests a role for corticotropin-releasing factor (CRF) in the regulation of pair bonding in prairie voles. We have previously shown that monogamous and non-monogamous vole...Full Text Available
A G-matrix, derived from a meson-exchange potential in nuclear matter, is applied to finite, semi-magic nuclei. For the open shell the broken-pair model, which can accommodate many single-particle levels, is used. The excitations of the closed shell are treated as particle-hole states. Energy spectra and electromagnetic transition densities are calculated for /sup 88/Sr and /sup 58/Ni. The energies of the non-collective states are well described. Pairing correlations in the ground state have almost the correct strength in a multishell model space. To improve the energies of the collective 2/sup +/ and 3/sup -/ states the inclusion of core-polarisation effects in the force is required. Transition charge densities for collective states become strongly surface-peaked by core-polarisation effects, as is observed in experiments. The effects of pairing correlations and core polarisation on the magnetic form factor of the 3.486 ...
A G-matrix, derived from a meson-exchange potential in nuclear matter, is applied to finite, semi-magic nuclei. For the open shell the broken-pair model, which can accommodate many single-particle levels, is used. The excitations of the closed shell are treated as particle-hole states. Energy spectra and electromagnetic transition densities are calculated for "8"8Sr and "5"8Ni. The energies of the non-collective states are well described. Pairing correlations in the ground state have almost the correct strength in a multishell model space. To improve the energies of the collective 2"+ and 3"- states the inclusion of core-polarisation effects in the force is required. Transition charge densities for collective states become strongly surface-peaked by core-polarisation effects, as is observed in experiments. The effects of pairing correlations and core polarisation on the magnetic form factor of the 3.486 MeV 1"+ state in ...
BackgroundFormation of site specific genomic double strand breaks (DSBs), induced by the expression of a pair of engineered zinc-finger nucleases (ZFNs), dramatically increases the...Full Text Available
The “cloverleaf” base-pairing pattern was established as the structural paradigm of active tRNA species some 30 years ago. Nevertheless, this pattern does not accommodate the folding...Full Text Available
The construction of the linear isomorphous and relativistic semigroup, of the Lorentz group and of tachyons was done using a dual pair of space-times, where the sought realization of the parametric semigroup is the semigroup of relativist endomorphisms. The obtained relativistic semigroup of dual space-time transformations possesses certain theoretical-probability properties.
BackgroundGenotyping analysis using capillary DNA sequencing with fluorescently labeled primer pairs obtained by polymerase chain reaction (PCR) is widely used, but is expensive....Full Text Available
Several signatures of new physics accessible at the LHC either suffer from top-quark production as a significant background or contain top quarks themselves. In this talk, we present results on top quark physics obtained from the first LHC data collected by the CMS experiment.They include measurements of the top pair production cross section in various channels and their combination, measurements of the top quark mass, the single top cross section, a search for new particles decaying into top pairs, and a first look at the charge asymmetry.
We review some interesting virtual effects from the minimal supersymmetric model (MSSM) at {gamma}{gamma} colliders. We conclude that in the research respects, such as supersymmetric particle pair production, CP-violation and electroweak-like one-loop corrections in top quark pair production, the FCNC in the R{sub p}-violating MSSM, linear collider (LC) operating in photon-photon collision mode provides powerful facilities in the measurements of new physics objects. For a precise and thorough study of the new physics, the investigation of the supersymmetric quantum effects is necessary. (author)
We review some interesting virtual effects from the minimal supersymmetric model (MSSM) at #gamma##gamma# colliders. We conclude that in the research respects, such as supersymmetric particle pair production, CP-violation and electroweak-like one-loop corrections in top quark pair production, the FCNC in the R_p-violating MSSM, linear collider (LC) operating in photon-photon collision mode provides powerful facilities in the measurements of new physics objects. For a precise and thorough study of the new physics, the investigation of the supersymmetric quantum effects is necessary. (author)
By its very nature redox potential measurement is suitable for determining the concentration ratio of a stable redox pair through its interaction with a chemically inert electrode surface but not the absolute concentration of a material. The measured redox potentials agree only rarely with those which are easily calculable theoretically. No individual defined stable redox pair is available in power station water. It is therefore not simply possible to measure definable mixed potentials more precisely. For these reasons redox potential measurement in the power station, as also with other types of water, can no longer be regarded as an indicator, by which it can be established whether oxidizing or reducing materials predominate in the water.
By its very nature redox potential measurement is suitable for determining the concentration ratio of a stable redox pair through its interaction with a chemically inert electrode surface but not the absolute concentration of a material. The measured redox potentials agree only rarely with those which are easily calculable theoretically. No individual defined stable redox pair is available in power station water. It is therefore not simply possible to measure definable mixed potentials more precisely. For these reasons redox potential measurement in the power station, as also with other types of water, can no longer be regarded as an indicator, by which it can be established whether oxidizing or reducing materials predominate in the water. (orig.).
We present methods to measure the beam polarizations and the luminosity of [gamma][gamma] colliders at TeV energy scale. The beam polarizations of a [gamma][gamma] collider can easily be monitored by comparing the numbers of events of the processes [gamma][gamma] [yields] l[sup +]l[sup -] and [gamma][gamma] [yields] W[sup +] W[sup -], where l means e or [mu]. The luminosity of a [gamma][gamma] collider is also measurable by the event rate of W boson pair productions and the light lepton pair productions. (orig.)
Gaussian-process models are developed to detect genetic linkage using complete high-resolution maps of identity by descent between affected relative pairs. Approximations are given for the significance level and power of the likelihood-ratio test of no linkage and for likelihood-ratio confidence regions for trait loci. The sample sizes required to detect linkage by using different classes of affected relative pairs are compared, and the problem of combining data from different classes of relatives is discussed. 23 refs., 2 figs.
Feasibility of using sterile females for population suppression of Earias vittella (Fabricius) was evaluated by conducting studies on mating competitiveness of radiation sterilized females, both in individual pairs and in simulated large population conditions. Results showed that sterility induced by using a 10:1:1 ratio (sterile female: normal female: normal male) in single pair experiments and also in simulated large population conditions was more than 99.0 per cent. Release of radiation- sterilized females of E. vittella in natural populations has thus an excellent potential for population suppression. (author)
The total and differential atomic pair-correlation functions of an icosahedral (quasicrystalline) solid were determined for the first time, directly by the differential anomalous-x-ray-scattering technique using synchrotron radiation. The observed atomic distances involving uranium atoms in icosahedral Pd/sub 58.8/U/sub 20.6/Si/sub 20.6/ suggest the presence of a quasicrystalline sublattice with vertex decoration. The pair distribution functions in the icosahedral and amorphous phases are similar up to the second-nearest neighbors, or up to 6 A-circle.
The total and differential atomic pair-correlation functions of an icosahedral (quasicrystalline) solid were determined for the first time, directly by the differential anomalous-x-ray-scattering technique using synchrotron radiation. The observed atomic distances involving uranium atoms in icosahedral Pd/sub 58.8/U/sub 20.6/Si/sub 20.6/ suggest the presence of a quasicrystalline sublattice with vertex decoration. The pair distribution functions in the icosahedral and amorphous phases are similar up to the second-nearest neighbors, or up to 6 A-circle.
Based on the exact results obtained by Bethe ansatz, we demonstrate the existence of stable bound pair (BP) wave packet in Bose Hubbard model with arbitrary on-site interaction U. In large-U regime, it is found that an incoming single-particle (SP) can coherently pass through a BP wave packet and leave a coherent shift in the position of it. This suggests a simple scheme for constructing a BP charge qubit to realize a quantum switch, which is capable of controlling the coherent transport of one and only one photon in a one-dimensional waveguide.
The recent measurements by the BES Collaboration of J/psi decays into a photon and a proton-antiproton pair indicate a strong enhancement at the proton-antiproton threshold not observed in the decays into a neutral pion and a proton-antiproton pair. Is this enhancement due to a proton-antiproton quasi-bound state or a baryonium? A natural explanation follows from a traditional model of proton-antiproton interactions based on G-parity transformation. The observed proton-antiproton structure is due to a strong attraction in the 1S0 state, and possibly to a near-threshold quasi-bound state in the 11S0 wave.
Gas quenching for the hardening of steel parts is a lower-pollution alternative to quenching in quenchants such as oil or salt. As the surfaces of the cooled parts remain clean after gas quenching, there is no need to wash them after heat treatment, which reduces the consumption of oils and detergents. The fire risk and ventilation requirements of oil quenching are eliminated. In addition, some trials have shown that gas quenching has a positive effect on distortion, representing a saving in finishing work and thus a reduction in costs. Today, gas quenching is used almost solely in vacuum furnaces. Quenching is normally performed in the same chamber as heating, which means that besides quenching the batch, the quenching system must also remove heat from the heating elements and insulation of the furnace. Previous trials performed by IVF have shown that gas quenching with helium of ball bearing and carburizing steels (and other steels) in sizes up to 25 mm at ...
A homogeneous turbulent mixing of coolant flows with different temperatures at the fuel assembly inlets is an important requirement to minimize hot spots in a fuel assembly of a High Performance Light Water Reactor (HPLWR). Therefore, the mixing chamber between lower core plate, flow adjuster and the mixing chamber within the cluster foot piece diffuser have been investigated using the Computational Fluid Dynamics (CFD)-code Fluent 6.1 and its implemented k-#epsilon# model. The previously presented 3D-CAD-geometry has been simplified using Gambit 2.1.2 and consists of various inlet and outlet tubes or channels in the foot piece bottom plate, the lower core plate and the flow adjuster establishing the boundaries of two consecutive mixing chambers. The temperature distribution at the inlet of the sub-channels of the cluster fuel assemblies is presented. It reveals temperature variations at the coolant inlet of the nine fuel ...
The performance of jet fuel with an oxidant mixture containing 70 percent liquid fluorine and 30 percent liquid oxygen by weight was investigated in a 500-pound-thrust engine operating at a chamber pressure of 300 pounds per square inch absolute. A one-oxidant-on-one-fuel skewed-hole impinging-jet injector was evaluated in a chamber of characteristic length equal to 50 inches. A maximum experimental specific impulse of 268 pound-seconds per pound was obtained at 25 percent fuel, which corresponds to 96 percent of the maximum theoretical specific impulse based on frozen composition expansion. The maximum characteristic velocity obtained was 6050 feet per second at 23 percent fuel, or 94 percent of the theoretical maximum. The average thrust coefficient was 1.38 for the 500-pound thrust combustion-chamber nozzle used, which was 99 percent of the theoretical (frozen) maximum. Mixtures of fluorine and oxygen were found to be ...
A computer model of cryogenic system for storing solid antimatter is used to explore the radiative cooling-power requirements for long-term antimatter storage. If vacuum-chamber pressures as low as 10 to -18th power torr can be reached, and the rest of the large set of assumptions is valid, milligram quantities of solid antimatter could be stored indefinitely at 1.5 K using cooling powers of less than a microwatt. Many of the assumptions made are problematic and need verification, as they could potentially change the results greatly. The system modeled is a sphere of solid anti-parahydrogen at 1.5 K or below levitated in a spherical cryogenic vacuum chamber. The free matter gas in the chamber is assumed to be molecular hydrogen, and sublimation of both matter and antimatter is assumed to be negligible. The antihydrogen is assumed to be in thermal equilibrium, although annihilation-energy deposition is localized and ...
The United States Air Force School of Aerospace Medicine (USAFSAM) tests the quantitative fit of masks which are worn by military personnel during nuclear, biological, and chemical warfare. Subjects are placed in a Dynatech-Frontier Fit Testing Chamber, salt air is fed into the chamber, and samples of air are drawn from the mask and the chamber. The ratio of salt air outside the mask to salt air inside the mask is called the quantitative fit factor. A motion-time study was conducted to evaluate the efficiency of the layout and work method presently used in the laboratory. A link analysis was done to determine equipment priorities, and the link data and design guidelines were used to develop three proposed laboratory designs. The proposals were evaluated by projecting the time and motion efficiency, and the energy expended working in each design. Also evaluated were the lengths of the equipment links for each proposal, and ...
We investigated a method of analyzing the hemodynamics of the lung mass by contrast enhanced dynamic computed tomography (dynamic CT) to determine the difference in vascular supply between the pulmonary artery and bronchial artery using an experimental model. Our experimental model consisted of two injectors connected to two tubes, representing the pulmonary artery and bronchial artery, which were further connected to a chamber representing the lung mass. Following infusion of contrast medium into each tube with some delay time, dynamic CT scans were performed to obtain time density curves of the two tubes and the chamber. Using the time-density curve of contrast passage, flow rates from the two tubes into the chamber were calculated by the curve fitting method. Calculated values correlated well with the adopted flow rates of fluid from the injectors (r=0.893) in the experiment. The results indicate our method of ...
We investigated a method of analyzing the hemodynamics of the lung mass by contrast enhanced dynamic computed tomography (dynamic CT) to determine the difference in vascular supply between the pulmonary artery and bronchial artery using an experimental model. Our experimental model consisted of two injectors connected to two tubes, representing the pulmonary artery and bronchial artery, which were further connected to a chamber representing the lung mass. Following infusion of contrast medium into each tube with some delay time, dynamic CT scans were performed to obtain time density curves of the two tubes and the chamber. Using the time-density curve of contrast passage, flow rates from the two tubes into the chamber were calculated by the curve fitting method. Calculated values correlated well with the adopted flow rates of fluid from the injectors (r=0.893) in the experiment. The results indicate our method of ...
Causes of variation of hydrocarbon (HC) concentration in cylinder to cylinder at idling condition in a direct injection diesel engine were studied. The ratio of l/d=6 gives larger HC variation in cylinder to cylinder than the l/d=2, where l means the nozzle hole length and d means the nozzle hole diameter. This is because the condition of l/d=6 can result in the large spray penetration and increase the fuel on the combustion chamber. The spray structure changes between nozzles and also changes between nozzle holes. This is not caused by the shape of nozzle hole but is affected by the pressure change near the inlet of nozzle hole when the needle valve is lifted. The change of spray structure can change the injection volume between nozzle holes. The injection volume is less for a nozzle hole where the curved angle becomes sharp to the nozzle central angle, and is more at the opposite side. When the injection volume of the nozzle hole near the ...
Both horizontally and vertically oriented rotating chambers with granular material held on the inner surface by centrifugal action are examined. Modifications to the condition for controlled quasi-static flow on an incline plane, phi/sub w/ < #alpha# < phi/sub r/, where phi/sub w/ is the wall friction angle, #alpha# is the angle of inclination of the plane, and phi/sub r/ is the drained angle of repose of the material are examined for the case of horizontal and vertical surfaces of revolution. Allowed included half angles for horizontally oriented chambers are likely to be in the range of 30"0 +- 10"0 for ceramic particles and metal surfaces. For vertical orientations the maximum half-angle of the top cone is slightly less than the wall friction angle phi/sub w/ while the lower portion can have a half angle as large as (90"0 - phi/sub w). Percolation of fines through shearing granular solids is briefly discussed and recommended ...
Apparatus and methods are described for generating heat and electricity from the consumption of a variety of aluminum products. The method consists of (A) a reaction chamber containing an aqueous electrolyte solution and adapted for introduction therein of aluminum pieces of various shapes and sizes up to a certain maximum predetermined size and for effecting a chemical reaction between said aqueous electrolyte and said aluminum pieces yielding aluminum hydroxide and an intermediate reactant; (B) means for feeding said aluminum pieces into said reaction chamber in small quantities upon demand; (C) means for removing the heat generated in said chamber as a result of said reaction; (D) means for removing said aluminum hydroxide reaction product; and (E) means for oxidizing said intermediate reactant in an electrochemical cell, thereby generating electrical energy. The intermediate reactant is preferably hydrogen or zinc. The ...
Apparatus and methods for generating heat and electricity from the consumption of a variety of aluminum products comprise: (A) a reaction chamber containing an aqueous electrolyte solution and adapted for introduction therein of aluminum pieces of various shapes and sizes up to a certain maximum predetermined size and for effecting a chemical reaction between said aqueous electrolyte and said aluminum pieces yielding aluminum hydroxide and an intermediate reactant; (B) means for feeding said aluminum pieces into said reaction chamber in small quantities upon demand; (C) means for removing the heat generated in said chamber as a result of said reaction; (D) means for removing said aluminum hydroxide reaction product; and (E) means for oxidizing said intermediate reactant in an electrochemical cell, thereby generating electrical energy. The intermediate reactant is preferably hydrogen or zinc. The latter may be used in a ...
The front-end electronics system for the anode signals of the CMS Endcap Muon cathode strip chambers has about 183000 channels. The purposes of the anode front-end electronics are to acquire precise muon timing information for bunch crossing number identification at the Level-1 muon trigger system and to provide a coarse radial position of the muon track. Each anode channel consists of an input protection network, amplifier, shaper, constant-fraction discriminator, and a programmable delay. The essential parts of the electronics include a 16-channel amplifier-shaper-discriminator ASIC CMP16 and a 16-channel ASIC D16G providing programmable time delay. The ASIC CMP16 was optimized for the large cathode chamber size (up to 3 x 2.5 m2) and for the large input capacitance (up to 200 pf). The ASIC combines low power consumption (30 mW/channel) with good time resolution (2 - 3 ns). The del ay ASIC D16G makes possible the alignment of signals with an ...
The results of an experimental investigation of the performance of a small bore engine with a swirl chamber when operating as a dual fuel engine with commercial methane as the gaseous fuel were presented in this paper. The experiment involved using a 3-dimensional computational fluid dynamics model to predict the performance of the engine. A detailed chemical kinetics for the gaseous fuel component, consisting primarily of methane and a reduced detailed chemical kinetics for the diesel fuel while considering the turbulent combustion processes an associated performance of a dual fuel engine with a swirl chamber were incorporated in the simulation. The study experimentally and numerically investigated the effects of changes in the quantities of the liquid fuel pilot and gaseous fuels on the combustion processes, engine performance, cyclic variations, and emissions. The paper discussed the experimental approach and results. It also discussed the ...
The LHCb Muon detector system is made of several (1368) Multi Wire Proportional Chambers (MWPCs). Those chambers differ in size, readout and constructing materials and are built in various countries: their assembly takes place in different sites and foresee many steps. To ensure the production quality and keep track of panels/chambers production an on-line database has been set up. This web based tool allows an easy sharing of the information: the database update is made possible trough a web interface. The update is easy and reliable. The interface helps the information sharing in different sites and helps optimizing the production rate by allowing feedback on production needs and quality between sites contributing to the production chain. The planning is made using the information on the material availability. Quality tests and crosschecks are made easier, as well as the overall production monitoring. The tool has been ...
The use of primary electron counting techniques as an alternative to the more usual parallel plate avalanche chamber that has been employed in soft x-ray scattering experiments is being investigated at the National Synchrotron Light Source. The theoretical aspects of primary electron counting and motivation behind building a primary electron counting detector are described, as well as characteristics and future improvements of the device constructed at the NSLS. The detector consists of a low electric field drift region and a low pressure multistep avalanche region which can be operated with two or three stages of electron multiplication. The device has worked well in extensive tests as a simple parallel plate avalanche chamber, providing energy resolutions of 58% and 43% at 277 and 500 eV, respectively. Operated as a primary electron counter, preliminary results show an energy resolution of 38% at 500 eV.
We formulate a complete theory of Edge Radiation based on a novel method relying on Fourier Optics techniques. Similar types of radiation like Transition Undulator Radiation are addressed in the framework of the same formalism. Special attention is payed in discussing the validity of approximations upon which the theory is built. Our study makes consistent use of both similarity techniques and comparisons with numerical results from simulation. We discuss both near and far zone. Physical understanding of many asymptotes is discussed. Based on the solution of the field equation with a tensor Green's function technique, we also discuss an analytical model to describe the presence of a vacuum chamber. In particular, explicit calculations for a circular vacuum chamber are reported. Finally, we consider the use of Edge Radiation as a tool for electron beam diagnostics. We discuss Coherent Edge Radiation, Extraction of Edge Radiation by a mirror, and ...
The isothermal flow field for the axial cyclone has been experimentally determined. The velocity fields are used for determination particle paths (particle removal and suspended state), and inter alia of heat and mass transfer processes in the axial cyclone combustion chamber. The results are extremely significant as input value approximations for mathematical modelling, since experimentally obtained results are indispensable for complex flows and geometries. (orig.) [Deutsch] Es ist fuer den Axialzyklon experimentell das isotherme Stroemungsfeld ermittelt. Die Geschwindigkeitsfelder dienen zur Ermittlung der Partikelbahnen (Partikelabscheidung, Schwebebedingung), der Waerme- und Stoffuebertragungsprozesse u.a. in der Axialzyklonbrennkammer. Die Ergebnisse sind als Startwertnaeherung bei einer mathematischen Modellierung sehr wichtig, da bei komplexen Stroemungen und Geometrien versuchstechnische Ergebnisse unumgaenglich sind. (orig.)
The major bottleneck for popularization and utilization of the conventional mechanical valve pulse combustors is the self-priming mode of gas supply. An aerodynamic valve (as against mechanical valve) self-excited pulse combustor of the Helmholtz-type with continuous supply of gas and air was designed and a mathematical model was established in this paper. The theoretical model employed well-stirred reactor model and a single step Arrhenius chemistry, and took those factors which might affect the combustion stability into account. The factors include the variation of the mass rate of the reactants affected by the pressure in the combustion chamber, the convective and radiation heat loss in the combustion chamber, and the heat transfer and wall friction in the tailpipe. The effect of wall t...
A method for determining the mobility of hydrogen as a function of temperature in superconducting niobium cavities comprising: 1) heating a cavity under test to remove free hydrogen; 2) introducing hydrogen-3 gas into the cavity; 3) cooling the cavity to allow absorption of hydrogen-3; and 4) measuring the amount of hydrogen-3 by: a) cooling the cavity to about 4.degree. K while flowing a known and regulated amount of inert carrier gas such as argon or helium into the cavity; b) allowing the cavity to warm at a stable rate from 4.degree. K to room temperature as it leaves the chamber; and c) directing the exit gas to an ion chamber radiation detector.
Research was performed to assess the feasibility of barrier membrane substances, for use within mining or associated high risk environments, in restricting the diffusion transport of radon gas quantities. Specific tests were conducted to determine permeability parameters of a variety of membrane materials with reference to radon flow capabilities. Tests were conducted both within laboratory and in-situ emanation environments where concentrations and diffusion flows of radon gas were known to exist. Equilibrium radon gas concentrations were monitored in initially radon-free chambers adjacent to gas sources, but separated by specified membrane substances. Membrane barrier effectiveness was demonstrated to result in reduced emanation concentrations of radon gas within the sampling chamber atmosphere. Minimum gas concentrations were evidenced where the barrier membrane material was shown to exhibit lowest radon permeability characteristics.
This patent describes a low emission duel fuel engine system. It comprises: a dual fuel engine having a combustion chamber; a fuel oil supply connected to the engine; a fuel gas supply connected to the engine; and means connected between the fuel oil supply and the engine for injecting fuel oil into the engine. The means connected between the engine and fuel oil supply limiting the injection of fuel oil to the combustion chamber to pilot ignition quantities only, wherein the limiting means includes means for limiting the injection of fuel oil such that the exhaust emission of NO{sub x} is at an emission rate of less than 1 GM/PH-HR, whereby the exhaust emission performance of the dual fuel engine is enhanced.
The light gain due to S/sub 2/ molecules in a supersonically cooled gas mixture is calculated. The S/sub 2/ molecules formed due to the recombination of the sulfur atoms, and the combustion gas mixture was preheated in a precombustion chamber. Optimal gas flow and nozzle parameters are found which correspond to the highest possible light gain using Cs/sub 2/-Ar and S/sub 2/-Ar gas mixtures. The steady state gas flow in the nozzle was calculated, taking into account the chemical reactions in the one-dimensional approximation. It is shown that the maximum gain values vary in the 0.0001-0.002 range for gas pressures in the precombustion chamber in the range 10-100 atm. The optimal initial relative concentration of Cs/sub 2/ molecules and S/sub 2/ molecules are given. 32 references.
A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a {sup 241}Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).
A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a "2"4"1Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).
This paper presents a reformer prototype for the production of the necessary H{sub 2} to supply a 5 kW PEMFC and its first results. The fuel processor consists of an OSR and a WGS and a PROX reactors. The design of the system was carried out with a one-dimensional model. The mixture chamber was specially studied with a CFD code (Fluent), taking into account the effect of fuel evaporation and the cool flame process. The aim of the designed facility is to be able of characterising each component and controlling each working parameter. Eventually, using diesel as fuel, results from the mixture chamber, OSR, WGS and PROX reactors are presented. It also includes conclusions and future works. (authors)
A method is described for controlling fuel injection in a diesel engine having a fuel injection nozzle, comprising the steps of: detecting an idling state of the diesel engine and pressure in a combustion chamber; obtaining a pressure increment rate from the pressure detected by the detecting step; selecting a valve opening pressure of the fuel injection nozzle at a relatively low level when the idling state is detected by the detecting step, thereby setting a two peaks characteristics of a fuel injection rate; and controlling the fuel injection nozzle in response to the pressure increment rate so that the pressure increment rate in the combustion chamber is maintained within a predetermined value by changing a fuel injection quantity of a pilot injection from the fuel injection nozzle.
In order to replace copper fungicides in organic potato production, 53 copper-free preparations (CFPs) based on natural compounds, including plant extracts and microorganisms, and five copper preparations were evaluated for their potential to control Phytophthora infestans, the pathogen that causes late blight of potatoes. In in vitro assays, 30% of the CFPs inhibited indirect germination of sporangia, 26% mycelial growth and in growth chamber experiments, 21% efficiently reduced foliar blight of tomato plants. In micro-plot field trials with applications twice a week, the copper preparations were the most effective and reduced foliar blight by 99%. Of the CFPs tested, Oekofluid P, Mycosin and other sulphuric clays, and C-2000 reduced late blight the most, from 63% to 37%. In small-plot tr...
An apparatus for measuring the overall decontamination factors of first and second filters located in a plenum. The first filter separates the plenum's upstream and intermediate chambers. The second filter separates the plenum's intermediate and downstream chambers. The apparatus comprises an aerosol generator that generates a challenge aerosol. An upstream collector collects unfiltered aerosol which is piped to first and second dilution stages and then to a laser aerosol spectrometer. An intermediate collector collects challenge aerosol that penetrates the first filter. The filtered aerosol is piped to the first dilution stage, diluted, and then piped to the laser aerosol spectrometer which detects single particles. A downstream collector collects challenge aerosol that penetrates both filters. The twice-filtered aerosol is piped to the aerosol spectrometer. A pump and several valves control the movement of aerosol within the ...
We report on aging measurements of a photon detector candidate for the HERA-B RICH. The prototype, a proportional wire chamber operated with TMAE, was mounted on an argon filled test-beam RICH and was aged by UV light at rates we expect in HERA-B. We monitored gain and current continuously, and checked the chamber with Cherenkov photons at regular intervals. The number of detected photons/track (projected to 2.75 m C sub 4 F sub 1 sub 0 in HERA-B) dropped from 26 to 11 after two days of aging - well below the 20 required for pi/K separation. Based on these results, HERA-B decided to use multi-anode PMTs as photon detectors in the RICH.
The modeling methods used to compute the neutron-induced activation of target and near-target materials in the NIF facility are presented. A detailed space and energy description of the neutron environment in the different materials is provided. A new capability has been developed to treat in a general way the activation of debris produced in an operational regime of yield and no-yield experiments. First calculations are addressed to analyze the activity of the debris into the target chamber. The contribution of the different components to activity, interior dose rates, and waste disposal rating (WDR) is determined. The importance of the activation coming from primary irradiation in the target, and from secondary irradiation in debris deposited onto the first wall is assessed. Finally, waste hazards of the activated debris when removed out of the chamber and stored are analyzed. (authors)
Magnolia bark and ginger rhizome is a drug pair in many prescriptions for treatment of mental disorders in traditional Chinese medicine (TCM). However, compatibility and synergism mechanism of two herbs on antidepressant actions have not been reported. The aim of this study was to approach the rationale of the drug pair in TCM. We evaluated antidepressant-like effects of mixture of honokiol and magnolol (HMM), polysaccharides (PMB) from magnolia bark, essential oil (OGR) and polysaccharides (PGR) from ginger rhizome alone, and the possibility of synergistic interactions in their combinations in the mouse forced swimming test (FST) and tail suspension test (TST). Serotonin (5-HT) and noradrenaline (NE) levels in prefrontal cortex, hippocampus and striatum were also examined. 30 mg/kg HMM decreased immobility in the FST and TST in mice after one- and two-week treatment. OGR (19.5 or 39 mg/kg) alone was ineffective. The combination of an ...
The energy distribution of ion beams is important especially for low energy ion beam applications. The energy distributions of negative-ion beams produced through secondary ion emission by sputtering were measured and compared with theoretically estimated distributions by use of four different negative-ion production probability equations (modified surface ionization model, exponential velocity dependence model, and our modified exponential velocity dependence models (modified decaying factor model and combination model of velocity dependence and surface ionization)). In the measurements, the energy distributions of C"- and Ag"- beams had a peak at a few to several eV and the full width at half maximum were 15 eV and 11 eV, respectively. These results could be well explained by the estimated distributions by virtue of our combination model or the modified surface ionization model. copyright 1996 American Institute of ...
Estimations on the somatic and genetic effects of small doses of ionizing radiations in Man have been proposed by the Advisory Committee on the Biological Effects of Ionizing Radiation, set up by the U.S. National Academy of Sciences. They have been published in an important report, issued in 1972, from which we briefly analyze here the Chapter dealing with the somatic effects. Small doses of raditions are expected to promote only carcinogenic effects. After a rapid survey of the human experience on which the estimations are based, as regards the latent period of cancers, the plateau region (period of high risk) and the absolute and relative risk expressed per rem, per 10"6 persons, per year, for leukaemia (having the highest risk) and for the ''other cancers''. These estimations were obtained by linear extrapolation to the 1 rem level from observations made after irradiation at relatively high dose levels and much higher dose-rates. This ...
This thesis reports investigations using gamma-radiation to decontaminate poultry carcasses. The application to foods of doses of ionizing radiation sufficient to reduce the number of viable specific non-sporeforming pathogenic microorganisms so that none is detectable in the treated food by any standard method is termed radicidation. The doses used in this study were at such a level that no undesirable or unfavourable side-effects occurred. The effects of these doses were studied on salmonellae and other microorganisms present in, or associated with poultry carcasses and in liquid and on solid culture media as well. Decimal reduction (D_1_0) values were estimated. These represent the dose (kGy) required to achieve a reduction in initial colony count from N_0 to 0.1 N_0. Together with the estimation of the numbers of Salmonella present per carcass the data were used to predict the effect of an ionizing radiation treatment of poultry. Data on ...
The introduction of positron emission tomography (PET)/magnetic resonance (MR) systems into medical practice in the foreseeable future may not only lead to a gain in clinical diagnosis compared to PET/computed tomography (CT) imaging due to the superior soft-tissue contrast of the MR technology but can also substantially reduce exposure of patients to ionizing radiation. On the other hand, there are also risks and health effects associated with the use of diagnostic MR devices that have to be considered carefully. This review article summarizes biophysical and biological aspects, which are of relevance for the assessment of health effects related to the exposure of patients to both ionizing radiation in PET and magnetic and electromagnetic fields in MR. On this basis, some considerations concerning the justification and optimization of PET/MR examinations are presented - as far as this is possible at this very early stage. Current safety ...
Optical Isotope shift measurements have been performed for the {sup 240f,242f}Am fission isomers to test the stability of nuclear deformation as function of the neutron number. The method is based on resonance ionization spectroscopy (RIS) in a buffer gas cell with fission detection of the ionization process. The {sup 240f,242f}Am fission isomers have been produced by {sup 242}Pu(p, 3n), {sup 242}Pu(d, 2n) reactions, respectively. Relative isotope shift ratios X{sub exp}{sup 242f}(500 nm)=IS{sup 242f,241}/IS{sup 243,241}=41.4(8) and X{sub exp}{sup 240f}(500 nm)=IS{sup 240f,241}/IS{sup 243,241}=39.2(8) were measured. From these ratios a small difference {delta}{beta}{sub 2}{sup 242f,240f}=0.0076(14) of the deformation parameter {beta}{sub 2} can be deduced assuming that the isotope shift between the reference isotopes {sup 241,243}Am is caused by a pure volume change. (orig.)
Recently developed oxygen O18 method [K. Franzreb, J. Lorincik, P. Williams, Surf. Sci. 573 (2004) 291; R.C. Sobers, K. Franzreb, P. Williams, Appl. Surf. Sci. 231-232 (2004) 729; P. Williams, R.C. Sobers Jr., K. Franzreb, J. Lorincik, Appl. Surf. Sci. 252 (2006) 6429] is able to quantitatively determine the flux ratio of oxygen to matrix species at dynamical SIMS sputtering. This flux ratio can be directly related to the surface oxygen concentration at dynamical sputtering - an important parameter controlling the ionization yield of emitted species. It is argued that the oxygen O18 method is a worthy step forward in gathering relevant experimental data that might eventually lead to the understanding of oxygen enhancement mechanism in SIMS. A current status of understanding of the ionization processes in SIMS is briefly discussed in terms of non-adiabatic strongly velocity dependent processes represented by the electron tunneling and ...
The recent development of matrix-assisted UV laser desorption (LD) mass spectrometry has made possible the ionization and detection of extremely large molecules (with molecular weights exceeding 100,000 Daltons). This technique has generated enormous interest in the biological community for the direct examination of large peptides and oligonucleotides. Although this matrix-assisted ionization method has been developed and used almost exclusively with time-of-flight (TOF) mass spectrometers, research is currently in progress to demonstrate this technique with trapped ion mass spectrometers, such as Fourier transform ion cyclotron resonance mass spectrometry (FTMS). The potential capabilities of FTMS for wide mass range, high resolution measurement, and ion trapping experiments suggest that this instrumental technique should be useful for the detailed structural characterization of large ions generated by the matrix-assisted technique. We have ...
The narrow emission line spectra of active galactic nuclei are not accurately described by simple photoionization models of single clouds. Recent Hubble Space Telescope images of Seyfert 2 galaxies show that these objects are rich with ionization cones, knots, filaments, and strands of ionized gas. Here we extend to the narrow line region the ``locally optimally emitting cloud'' (LOC) model, in which the observed spectra are predominantly determined by powerful selection effects. We present a large grid of photoionization models covering a wide range of physical conditions and show the optimal conditions for producing many of the strongest emission lines. We show that the integrated narrow line spectrum can be predicted by an integration of an ensemble of clouds, and we present these results in the form of diagnostic line ratio diagrams making comparisons with observations. We also predict key diagnostic line ratios as a function of distance ...
K beta X-ray lines from partially M-shell-ionized ions of titanium through nickel which are produced in vacuum-spark plasmas have been observed systematically for the first time, using a high-resolution curved-crystal spectrometer. Each K beta line is clearly separated into its corresponding charge state. As a result, it is possible to measure the K beta-type transition energies of the M-shell-ionized ions. The transition energies accurately determined are compared with those calculated for iron ions, and the agreement is excellent except for ions having some additional 3d outer-shell electrons or 3s inner-shell vacancies. The square root of the K beta transition frequency is expressed as a linear function of the nuclear charge for isoelectronic sequences. The effective nuclear charges have been also determined for each K beta transition. The 3p electrons do not affect the effective nuclear charges. 10 references.
Thick targets of several heavy lanthanide (Ho-Lu) compounds were bombarded by protons and /sup 3/He ions of 3 MeV/amu, and M/sub ..cap alpha../ and M/sub ..beta../ X-rays were measured with a crystal spectrometer. Ionization probabilities of the N-shell for zero impact parameter were obtained from the X-ray intensity ratio for proton and /sup 3/He ion impacts. A shell dependence of the ionization probability was found in a scaling plot. X-ray spectra of lanthanide compounds were compared and no chemical effect was observed. This result is considered to be due to the fact that the main component of M/sub ..cap alpha../ and M/sub ..beta../ lines is for radiative transition after the refilling of the 4f orbit (3d/sup -1/4f/sup n+1/ -> 4f/sup n/) where n denotes the number of 4f electrons of the target atom before ionization.
Ignoring the numerous, known and mainly unknown, interactions between chemicals and ionizing radiations, causes strong controversy about the risks of ionizing radiations. Yet the best known interactions between chemicals and radiations is that between radon and tobacco smoke. Although it is and it will be always impossible to derive quite quantitative laws for this interaction, it has been possible to derive some semi-quantitative relationships based on reasonable assumptions and statistics on lung cancer deaths in developed countries. They show that ignoring the dangers of tobacco smoking as we did still long after we had recognised the dangers of radiations, could asses to radiations thirty or forty times more risks than reality. As present world is flown by tens of thousands chemicals, little or not present in a natural environment, and as it would be very surprising that some hundreds of these do not behave like those contained in tobacco ...
Gemini North adaptive optics imaging spectroscopy is presented for the Galactic ultra-compact HII (UCHII) region K3-50A. Data were obtained in the K-band using the Near-infrared Integral Field Spectrograph (NIFS) behind the facility adaptive optics module ALTAIR in natural guide star mode. The NIFS data cube reveals a complex spatial morphology across the 0.1 pc scale of the 3'' UCHII region. Comparison of the nebular emission to Cloudy ionization models shows that the central source must have an effective temperature between about 37000 K and 45000 K with preferred values near 40000 K. Evidence is presented for sharp density variations in the nebula which are interpreted as a clearing of material nearest the central source. High excitation lines of FeIII and SeIV show that the ionization of the nebula clearly changes with distance from the central source. A double lobed kinematic signature (+/- 25 kms) is evident in the Br gamma line map which ...
Selecting an appropriate matrix solution is one of the most effective means of increasing the ionization efficiency of phosphopeptides in matrix-assisted laser-desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). In this study, we systematically assessed matrix combinations of 2, 6-dihydroxyacetophenone (DHAP) and diammonium hydrogen citrate (DAHC), and demonstrated that the low ratio DHAP/DAHC matrix was more effective in enhancing the ionization of phosphopeptides. Low femtomole level of phosphopeptides from the tryptic digests of ?-casein and ?-casein was readily detected by MALDI-TOF-MS in both positive and negative ion mode without desalination or phosphopeptide enrichment. Compared with the DHB/PA matrix, the optimized DHAP/DAHC matrix yielded superior sample homogeneity and higher phosphopeptide measurement sensitivity, particularly when multiple phosphorylated peptides were assessed. Finally, the ...
The aim of the present study was to test a mathematical model of the biochemical processes in the parathyroid glands responsible for the secretion of parathyroid hormone resulting from extracellular calcium reduction. A double exponential curve described the parathyroid hormone secretion induced by rapid lowering of blood-ionized calcium in humans with normal as well as abnormal parathyroid tissue. Our data show that it was possible to establish a simple mathematical model of the parathyroid hormone response to blood-ionized calcium lowering, sufficient to fit experimental data obtained from patients with abnormal and normal parathyroid tissue. The fitted parameters showed no significant differences between patients with insulin-dependent diabetes mellitus and controls. In primary hyperparathyroidism, the parathyroid hormone production and steady-state transport across the cell membrane were increased, probably due to the larger amount of ...
At the Savannah River Site (SRS), nuclear production reactors used de-ionizers to control the chemistry of the reactor moderator during their operation to produce nuclear materials primarily for the weapons program. These de-ionizers were removed from the reactors and stored as a legacy waste with no path to disposal due to the relatively high 14C contamination (i.e., on the order of 20 curies per de-ionizer for 48-50 de-ionizers) and the low disposal limit of 4.2 Ci previously established for the Intermediate Level Vault (ILV). The ILV is considered most appropriate facility within which to dispose these items due to the method of solidifying waste items with cementitious material inside concrete vaults. In previous analyses the 14C ILV disposal limit was established at 4.2 Ci resulting from the use of a very conservative method to analyze the dose received from atmospheric releases of gaseous 14C. ...
Microbiological comparison between irradiated and non-irradiated foodstuff has been studied for a long time as a way to detect whether a foodstuff has been irradiated or not. Generally, the proposed methods are based on the fact that ionization select species of bacteria which are recognized to be radioresistant. So reduction or elimination of known radiation sensitive microbes from the normal endogenous microflora could give an indication that the foodstuff has been irradiated, predominance of known radioresistant bacteria should be another indication. In the present work, we try to develop a test based on the radiosensitivity of the bacteria independently of their place. These first experiments show that the determination of radiosensitivity of strains isolated from a product or even of global radioresistance of mesophilic microflora could indicate if this product has been previously submitted to ionizing radiations. (4 tabs).
The authors address the question of the limitations on voltage and current transfer to loads in magnetic storage systems utilizing microsecond conduction time plasma opening switches. They propose that the limitation of performance results from neutral atoms that are not entrained into the ionized material that is driven by the magnetic field of the rising generator current. Evidence in support of this proposition is gathered from experiments performed on the Ace-4 and Hawk generators. They set forth a theory to describe the effect of neutrals on the electrical performance of plasma opening switches. The neutral gas is assumed to be present in the region between the moving plasma mass and the generator, primarily in the region in which the plasma is injected initially. The essential elements of the theory are a weak photoionization source to seed the gas with a low concentration of electrons, and joule heating accompanied by further ionization ...
All measurements were made with the NBS high-pressure photoionization mass spectrometer. The fractional of C/sub 5/H/sub 10//sup +/ions in a cyclopentane-cyclohexane mixture were determined as a function of pressure in order to define the fraction of the ions which did charge exchange with cyclohexane; i.e. the fraction which remained cyclic after ionization. The data for mixtures of various compositions (2.5 to 10% cyclohexane) are summarized for measurements performed at 10.62 eV: (a) 292K, > 96% cyclic; 347 K, greater than or equal to 94% cyclic; 386 K, 84 +- 4% cyclic; and 412 K, 78 +- 6% cyclic; entropy, enthalpy, and activation energy were determined; 10.49 eV was obtained as the ionization potential of cyclopentane. 1 figure.
Long before possible organic effects, exposure to ionizing radiations can provoke anxiety. In front of invisibility, the imagination quickly ignites. The terrorists have perfectly understood it. They are ready to use ionizing radiations as a weapon to remind traumatic images deeply rooted in people's memory. These images induce anxiety with all the clinical expressions connected to it. These symptoms require to be treated because of a possible anarchic development. For that purpose, plans have been elaborated to coordinate the different professional's actions. The coherence of medical management and communication aims to allow the most implicated people to find the way to face the events. When it is not possible, medico-psychological cells permit a specialized care. (author)
Recent research findings of epidemiologist Alice Stewart suggest that nuclear workers may be at risk of contracting cancer even though their measured occupational doses fall within current safety standards. It is argued that these standards are inappropriate as they are based on extrapolations of studies on survivors of the Hiroshima and Nagasaki explosions. These individuals received single doses of radiation, whereas today's nuclear industry personnel are exposed to low-level ionizing radiation over the length of their working lives. Stewart's team linked low dose occupational exposure to ionizing radiation with an increased risk of cancer in respiratory, digestive and blood-forming tissues. The nuclear industry and United States government agencies hotly contest these assertion with their potentially damaging political and economic consequences. (UK).
Recent research findings of epidemiologist Alice Stewart suggest that nuclear workers may be at risk of contracting cancer even though their measured occupational doses fall within current safety standards. It is argued that these standards are inappropriate as they are based on extrapolations of studies on survivors of the Hiroshima and Nagasaki explosions. These individuals received single doses of radiation, whereas today's nuclear industry personnel are exposed to low-level ionizing radiation over the length of their working lives. Stewart's team linked low dose occupational exposure to ionizing radiation with an increased risk of cancer in respiratory, digestive and blood-forming tissues. The nuclear industry and United States government agencies hotly contest these assertion with their potentially damaging political and economic consequences. (UK).
The book presents a very good account of all aspects of protection from ionizing radiation. The quantities and units are given and defined used in nuclear physics and dosimetry. The effects of ionizing radiation on cells and on man are described. The principles are presented of radiation protection including limits and valid regulations and decrees. Also discussed is internal irradiation and its modelling. A great part of the book is devoted to aspects of monitoring persons, the living and working environment and to the determination of internal contamination. The system of radiation protection in Czechoslovakia is described and some practical questions are discussed of protection during radiodiagnosis and radiotherapy, in the nuclear fuel cycle, in the operation of nuclear power installations and in crack detection. In conclusion a survey is given of the population exposure from various natural and artificial sources. (M.D.). 57 figs., 34 ...
An investigation was made of the accumulation of laser damage to transparent polymers irradiated with nanosecond pulses from neodymium and ruby lasers. The damage was investigated by the method of scattering and luminescence in the visible and near ultraviolet parts of the spectrum. It was established that there were two stages in laser damage by repeated irradiation with pulses of intensity below the single-shot damage threshold. An absorbing defect evolved during the first stage in such a way as to create a thermal instability in the surrounding matrix. During the second stage this thermal instability caused spatial growth of laser damage because of propagation of an ionization-inducing absorption wave with a front traveling at the rate governed by the electron component of the thermal conductivity.
Carcinogenesis is now generally recognized to be an important detrimental effect in man after low dose irradiation. The carcinogenic action of ionizing radiation is clearly demonstrated after exposure to relatively high doses (in excess of 0.5 Gy) but for lower dose levels reliable direct observations are not available. With the introduction of special protocols for the performance of large scale screening programs by mammography the average absorbed dose in glandular tissue in the average breast can be restricted to a value of 3 mGy per mammogram. The risk for tumor induction after exposure to these low doses can never be established from human epidemiology. In order to investigate the risk of repeated exposure to small dose of ionizing radiation the induction of mammary tumors has been investigated in rats of the WAG/Rij strain after single and fractionated irradiations with gamma-rays. (author). 8 refs., 3 figs.
Maintenance of genomic integrity in embryonic cells is pivotal to proper embryogenesis, organogenesis and to the continuity of species. Cultured mouse embryonic stem cells (mESCs), a model for early embryonic cells, differ from cultured somatic cells in their capacity to remodel chromatin, in their repertoire of DNA repair enzymes, and in the regulation of cell cycle checkpoints. Using 129XC3HF1 mESCs heterozygous for Aprt, we characterized loss of Aprt heterozygosity after exposure to ionizing radiation. We report here that the frequency of loss of heterozygosity mutants in mESCs can be induced several hundred-fold by exposure to 5-10Gy of X-rays. This induction is 50-100-fold higher than the induction reported for mouse adult or embryonic fibroblasts. The primary mechanism underlying the...
This paper reports extensive new optical and radio observations of NGC 5728, emphasizing the central regions. Deep photographs revealing detail in the faint spiral arms are briefly discussed. Broad-band UBV CCD images obtained to examine the colors of the stellar populations that comprise the bar and central ring are presented. The velocity field and emission maps obtained from imaging spectroscopic measurements in the H-alpha emission line are discussed. Conventional long-slit spectra covering the ionized gas in the nuclear region are described. Detailed maps of the radio emission in the central regions of NGC 5728 are presented. These combined data provide considerable evidence for the inflow of gas into the nuclear region, in response to the nonaxisymmetric gravitational potential of the bar. The possible relation of this phenomenon to the Seyfert nature of NGC 5728 is also considered. 48 references.
The main objectives of research in the field of health effects at the Belgian Nuclear Research Centre SCK-CEN are: (1) to study cancer mortality and morbidity in nuclear workers in Belgium; (2) to document the feasibility of retrospective cohort studies in Belgium; (3) to participate in the IARC study; (4) to elucidate the mechanisms of the effects of ionizing radiation on the mammalian embryo during the early phases of its development; (5) to assess the genetic risks of material exposure to ionizing radiation; (6) to elucidate the cellular mechanisms leading to brain damage after prenatal irradiation; (7) to advise authorities and to provide the general population with adequate information concerning the health risk arising from radiation exposure. Progress and major achievements in these topical areas for 1997 are reported.
Poly(lactic acid) (PLA) is attractive as a substitute for classical polymer packaging material due to its biodegradability and sufficient mechanical and barrier properties. Presented research was focused on the changes of basic mechanical parameters after ionizing irradiation performed with doses in the range of 2.5-25 kGy, commonly used in radiation sterilization and preservation of foods. Two commercial available PLA packaging films were tested. The influence of radiation dose on the mechanical properties - tensile strength and elongation were determined using standardized methods. Radiation resistance of PLA is sufficient for packaging applications. The investigations of gas products of radiolysis of PLA have been made by gas chromatography after electron beam (EB) irradiations. (authors)
Ionizing radiation has been used to treat poultry to remove harmful microorganisms, mainly Salmonella, which contaminates chicken, goose and other fresh and frozen poultry. This microorganism is sensitive to low dose radiation. Thus, irradiating these foods with doses between 1 to 7 kGy results in a large reduction of bacteria. Since it is necessary to determine whether irradiation has occurred and to what extend, this work studied the signal produced by ionizing radiation within the hard crystalline matrix of chicken`s bone to establish a control method. Chicken`s drumsticks were irradiated and bones separated from flesh were lyophilized and milled. ESR spectrum was then obtained. The ESR signal increased linearly with dose over the range 0.25 to 8.0 kGy. Free radicals evaluated during 30 days after irradiation showed stable in this period. (Author).
Photoelectron resonance capture ionization aerosol mass spectrometry (PERCI-AMS) has been applied to the analysis of proxies for marine aerosols with and without ozone; proxies used were mixed oleic acid-amino acid particles. The mechanism of ion formation for serine (104 m/z), glutamic acid (146 m/z), and phenylalanine (164 m/z) was dissociative electron attachment. This corresponds to loss of the hydrogen atom only, allowing for straightforward identification of the free amino acids. No ozonolysis products for the free amino acids were observed, even at high concentrations of ozone (500 ppm for 19 s). The direct detection of a novel gas-phase hydrated anion, [serine + H2O-H]-, is described. These preliminary results suggest that PERCI-AMS may provide an effective, simple and direct onlin...
The effects of strong Coulomb correlations in dense three-dimensional electron-hole plasmas are studied by means of unbiased direct path integral Monte Carlo simulations. The formation and dissociation of bound states, such as excitons and bi-excitons is analyzed and the density-temperature region of their appearance is identified. At high density, the Mott transition to the fully ionized metallic state (electron-hole liquid) is detected. Particular attention is paid to the influence of the hole to electron mass ratio $M$ on the properties of the plasma. Above a critical value of about M=80 formation of a hole Coulomb crystal was recently verified [Phys. Rev. Lett. {\\bf 95}, 235006 (2005)] which is supported by additional results. Results are related to the excitonic phase diagram of intermediate valent Tm[Se,Te], where large values of $M$ have been observed experimentally.
This paper reviews various techniques to harden Charged Coupled Device (CCD) sensors and the results after irradiation of three Thomson n buried channel CCDs having a different degree of hardening. It describes the major irradiation effects on CCD performances and it makes a comparison of the results between the different hardening levels. It shows good results on dark voltage after ionizing radiation for TH 7863M device hardened both by design and by operating conditions (MPP mode) with respect to the standard device TH 7863A. The irradiations were performed with "6"0Co or X-ray (10 keV) sources on devices in operating mode. (author). 3 refs., 8 figs.
Much theoretical and experimental efforts have been expended in recent years to study those atomic processes which are specially relevant to understanding high temperature laboratory plasmas. For magnetically confined fusion plasmas, the temperature range of interest spans from the hundreds of eV at plasma edges to 10 keV at the center of the plasma, where most of the impurity ions are nearly fully ionized. These highly stripped ions interact strongly with electrons in the plasma, leading to further excitation and ionization of the ions, as well as electron capture. Radiations are emitted during these processes, which easily escape to plasma container walls, thus cooling the plasma. One of the dominant modes of radiation emission has been identified with dielectronic recombination. This paper reviews this work.
High-spin states in the neutron-rich nuclei {sup 172,173}Yb have been populated in a {sup 170}Er({sup 7}Li,(p,d,t)xn) incomplete-fusion reaction and the emitted {gamma}-radiation was detected with the GASP array. The signature partners of the 7/2{sup +}[633] rotational band of the odd-N {sup 173}Yb isotope have been newly established and were observed up to spin values of (45/2{sup +}) and (43/2{sup +}), respectively. The ground-state band of the even-even nucleus {sup 172}Yb has been observed up to a spin value of (22{sup +}). No band crossings were found in these bands. To explain this observation, it is proposed that the static pair field is absent, considering that the neutron odd-even mass differences reach for these nuclei very small values and that the band crossing is absent in cranked shell modell calculations without pairing. The results indicate, however, that strong dynamic correlations are still present. (orig.)
The authors introduce the single electron (Cooper-pair) tunneling junctions using c-axis Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+d} (Bi-2212) superconducting single crystal whiskers. Focused-ion-beam (FIB) etching patterned the Bi-2212 whiskers. The fabricated small stacked junctions have in-plane area S smaller than <1 {micro}m{sup 2}. The junctions showed the current-voltage (I-V) characteristics with the periodic structure of current peaks. The stacking layered structure of Bi-2212 works as multi-junctions array which decrease the effective capacitance, C{sub {Sigma}} = C{sub 0}/N, where C{sub 0} is the capacitance of junction and N is the layer number of elementary junctions. The period of current peaks of I-V curves corresponds to the charging energy of the single Cooper pair, 2Ec (=e{sup 2}/C{sub {Sigma}}).
We calculate parity-dependent level densities for the even-even isotopes "5"8","6"2","6"6Fe and "5"8Ni and the odd-A nuclei "5"9Ni and "6"5Fe using the shell model Monte Carlo method. We perform these calculations in the complete fp-gds shell-model space using a pairing+quadrupole residual interaction. We find that, due to pairing of identical nucleons, the low-energy spectrum is dominated by positive parity states. Although these pairs break at around the same excitation energy in all nuclei, the energy dependence of the ratio of negative-to-positive parity level densities depends strongly on the particular nucleus of interest. We find equilibration of both parities at noticeably lower excitation energies for the odd-A nuclei "5"9Ni and "6"5Fe than for the neighboring even-even nuclei "5"8Ni and "6"6Fe.
The device for removing drilling fines from the well head includes a support disk encompassing the sucker rod of the drilling machine with frame made in the form of a dish with inner conical surface, and overturned truncated cone located in the dish of the support disk with the formation between them of a ring guide slit. In order to improve the effectiveness of removing the drilling fines and convenience of operation by excluding heavy manual auxiliary operations to clean the well head and to move the device from one well to another, it is equipped with a mechanism for suspension with a drive. The inner conical surface of the dish is equipped with slide blocks, while the overturned truncated cone is equipped with projections. The suspension mechanism is made in the form of a hydrocylinder and two pairs of levers connected in pairs by means of hinges. The hinges of each pair of levers are connected to the hydrocylinder, and ...
The method and results are presented of measurements of the coefficients of "2"2"2Rn emanation from samples of fly- ashes and slag and other commonly used building materials. A chamber was used for electrostatic collection of "2"2"2Rn decay products. The coefficients of emanation ranged from 0.2% (fly- ashes) to 21.3% (phosphogipsum from phosphorit). (author).
This book presents papers on internal combustion engines. Topics considered include the influence of partial suppression of heat rejection on performance and emissions, duothermic combustion, turbochargers made of sintered silicon nitrides, heat flux, low heat rejection engines, exhaust energy recovery, combustion chamber insulation, computerized simulation, heat transfer, friction, hoop stress effects, and bonding ceramics and metals.
Radon concentration measurements were made in the interior of the great pyramid of ''Cheops'' at Giza. Measurements were carried out using CR-39 as a solid state nuclear track detector. The CR-39 sheets were placed inside the Queen's and King's chambers and along the ascending corridor leading to them. An evaluation of the radon concentration is presented and discussed. (author).
Radon concentration measurements were made in the interior of the great pyramid of ''Cheops'' at Giza. Measurements were carried out using CR-39 as a solid state nuclear track detector. The CR-39 sheets were placed inside the Queen's and King's chambers and along the ascending corridor leading to them. An evaluation of the radon concentration is presented and discussed. (author).
Radon concentration measurement in the ground can be used for the prospecting for uranium and earthquake prediction. Some results of radon concentration measurement in the soil are presented here. The moisture condensation at the detector surface can affect on the detection efficiency. Due to this problem we tested a few filter papers on water permeability. The ratio of track densities on solid state nuclear track detector (SSNTD) in the open and the closed diffusion chamber is also determined. (author)
The radiation dose to a series of adult and paediatric patients undergoing cardiac catheterisations and adults having percutaneous transluminal coronary angioplasty has been measured/determined directly using lithium fluoride thermoluminescent dosemeters and indirectly using an air ionisation chamber which indicated exposure-area product. Somatic and genetic risks are estimated from the dosimetry results. It is suggested that the magnitude of the radiation hazard is negligible compared with other clinical hazards associated with these procedures. (author).
To evaluate a dose conversion factor from the `Working Level of Month` (WLM) of radon to the absorbed dose (mGy), the quality of radon and its progeny was assessed, and exposures controlled for each deposition region were planed as follows: 1) exposure of radon gas to the entire respiratory tract, 2) exposure of `unattached` fractions to the upper respiratory tract, 3) exposure of `attached` fractions onto ultrafine particles to the deep lung, 4) exposure of `attached` fractions onto fine particles to the lower respiratory tract, 5) exposure of `attached` fractions onto coarse particles to the upper respiratory tract. In this preliminary study, a prototype exposure system of radon and its progeny for small rodents was designed. A whole body exposure chamber with a volume of about 0.5 m{sup 3} was used, which it held 20 rats. The aging and mixing chamber separated by the exposure chamber had a volume of about 1 m{sup 3}. As ...
Technical studies on constructing the J-PARC (Japan Proton Accelerator Research Complex) are presented by five authors: (1) on the wiring for electromagnets of the 50 GeV synchrotron, (2) on the fast beam-extraction from the 50 GeV synchrotron into two opposite directions, (3) on the target chamber system for the generation of muons, (4) on the design of large aperture electromagnets, and (5) on the maintenance and control of the electromagnet power supplies. (K.Y.)
Water hyacinth (Eichhornia crassipes [Mart.] Solms) plants were grown in environmental chambers at ambient and enriched CO2 levels (330 and 600 microliters CO2...Full Text Available
Stereoscopic Particle Image Velocimetry (PIV) measurements are made in horizontal planes in a simplified scale model of a spray dryer using water as fluid. The sample rate was sufficient to resolve phenomena at lower frequencies. Data reveal asymmetric velocity fields in both mean fields and dynamics. Data were analysed using Proper Orthogonal Decomposition (POD). An important periodic event is an elongation of the jet core cross section that results in a downstream displacement of the jet towards the chamber wall.
MPFDs are a new class of detectors that utilize properties from existing radiation detector designs. A majority of these characteristics come from fission chamber designs. These include radiation hardness, gamma-ray background insensitivity, and large signal output.
As a part of a phenomenological model, a method for simulating the wall/jet interaction in a direct injection diesel engine is proposed. The method is based on the application of the momentum conservation equation in the different directions in which the wall jet is spread, and takes into account both the interaction with the combustion chamber geometry and with swirl. It takes as initial conditions the results of calculating the free jet, which is divided into packages. The predictions provide good agreement with those by other researchers. (author).
This study mainly concerns medical explorations by radioisotopes. Detectors with medical exams and applications are described. Ionisation chambers, semiconductor detectors and scintillation counters are also presented. Uses of radioisotopes in medicine in vivo and in vitro techniques are explained. Examples of scintiscanning are given like: angiography, nuclear cardiography and thyroid scintiscanning. The importance of the study is to present a panorama of nuclear medicine laboratories -at the time- in hospitals in Lebanon.
For the first time in China, Daya Bay Nuclear Power Station applied the advanced technology of worldwide commercial pressurized reactors to the in-core detectors, the leading excore six-chamber instrumentation for precise axial power distribution, and the related data processing. Described in this article are the neutron flux measurement in Daya Bay Nuclear Power Station, and the detailed data processing.
Complete text of publication follows. In order to extend the capabilities of the electron cyclotron resonance (ECR) ion source (ECRIS) of ATOMKI it has been transformed into a special plasma facility [1,2]. The transformation is reversible and was simply done by changing several main components of the ion source by new ones, namely: the hexapole magnet, the plasma chamber and the microwave source. The basic requirements of the transformation were: (1) most parts of the present ECRIS should be used in the new assembly in the same way and (2) the transformation time between the two operation modes should not be more than 2-3 days (in both directions). The following sub-systems are used identically in both configurations: solenoid coils, vacuum system, gas dosing system, ovens, probes. The extraction optics and beam transport system can also be used in the new configuration to check the components and charge-state of the plasma. A new, large, but unusually thin ...
The frequency dependence of the tunneling spectrum #alpha#"2F (#omega#) is analyzed in terms of electron pairing induced by exchange of acoustic plasmons in addition to the usual phonon-exchange mechanism. Analytic expressions are obtained for the electron self-energy, the tunneling function #alpha#"2F, and the electron pairing coupling lambda which determines the superconducting properties. The resulting theory is applied to recent tunneling data of Nb_3Sn in order to examine the anomalous discrepancies with the phonon density of states found by neutron scattering experiments. The results demonstrate how the high-temperature (T/sub c/ approx. 20 "0K) superconducting properties of A-15 compounds are enhanced by acoustic-plasmon contributions, and thus they reconcile these high transition temperatures with the relatively small values of the phonon part of lambda estimated from several independent experiments.
To test the assumption underlying every morphometric twin study that the brains of monozygotic twins are almost identical. Methods: High resolution MRI of the neurocranium of 26 monozygotic twin pairs were acquired and the volumes of 36 cerebral structures were measured. The same twins served as control group after rear-ranging them into non-related pairs of same sex and matching them for age, body height and body weight. Results: For most of the examined structures the correlations within the twins were significant (R = 0,97-0,59). Except for total forebrain volume the controls showed no significant similarity. Conclusions: For almost every measured cerebral structure the assumption, that significant similarities exist between healthy monozygotic twins is correct. Therefore discordant monozygotic twins represent an excellent sample when investigating cerebral correlates of neurologic and psychiatric disorders. (orig.)
Porcine pancreatic lipase immobilized on celite particles has been employed as a catalyst for the esterification of dodecanol and decanoic acid in a predominantly organic system. Solvent influence on the equilibrium position and on the catalyst activity has been studied using 20 solvents, including aliphatic and aromatic hydrocarbons, ethers, ketones, nitro- and halogenated hydrocarbons, and esters. The equilibrium constant for esterification correlates well with the solubility of water in the organic solvent, which in turn shows a good relationship with a function of Guttman's donor number and the electron pair acceptance index number of the solvent. This may be rationalized in terms of the requirements for solvation of water and of the reactants. The catalyst activity, measured as the initial rate of the esterification reaction, is best correlated as a function of both n-octanol-water partition coefficient (log P) and either the electron pair ...
The small-angle X-ray scattering technique was used to determine the intermolecular structure and interaction potentials in oxi-and deoxi-hemoglobin solutions. The pair correlation function obtained by the ZERNICKE-PRINS equation characterizes the intermolecular structure of the hemoglobin molecules. The intermolecular structure is concentration dependent. The hemoglobin molecules have a 'short range order structure' with a range of about 4 molecule diameters at 324 g/l. The potential functions of the hemoglobin-hemoglobin interaction have been determined on the basis of fluid theories. Except for the deoxi-hemoglobin solution having the concentration 370 g/l, the pair interaction consists in a short repulsion and a weak short-range attraction against kT. The potential minimum is between 1.2 - 1.5 nm above the greatest hemoglobin diameter. (author).
The authors present the results of a search for W{prime} boson decaying to electron-neutrino pairs in p{bar p} collisions at a center-of-mass energy of 1.96 TeV, using a data sample corresponding to 205 pb{sup -1} of integrated luminosity collected by the CDF II detector at Fermilab. They observe no evidence for this decay mode and set limits on the production cross section times branching fraction, assuming the neutrinos from W{prime} boson decays to be light. If they assume the manifest left-right symmetric model, they exclude a W{prime} boson with mass less than 788 GeV/c{sup 2} at the 95% confidence level.
We compute QCD corrections to the production of a ttbar pair in association with a hard photon at the Tevatron and the LHC. This process allows a direct measurement of the top quark electromagnetic couplings that, at the moment, are only loosely constrained. We include top quark decays, treating them in the narrow width approximation, and retain spin correlations of final-state particles. Photon radiation off top quark decay products is included in our calculation and yields a significant contribution to the cross-section. We study next-to-leading order QCD corrections to the ppbar -> ttbar+gamma process at the Tevatron for the selection criteria used in a recent measurement by the CDF collaboration. We also discuss the impact of QCD corrections to the pp -> ttbar+gamma process on the measurement of the top quark electric charge at the 14 TeV LHC.
The production of pairs of doubly charged vector bileptons is studied at future #gamma##gamma# colliders. The unpolarized cross section for the #gamma##gamma##->#Y"-"-Y"+"+ subprocess is analytically calculated and convoluted to predict the number of events in the complete e"+e"-#->##gamma##gamma##->#Y"-"-Y"+"+ process. The gauge or nongauge character of the vector bilepton Y"#+-#"#+-# is discussed. It is found that, as a consequence of its spectacular signature, as it decays dominantly into two identical charged leptons, and also due to its charge contents, which significantly enhance the cross section, the detection of this class of particles with mass in the sub-TeV region can be at the reach of these colliders. The model-independent nature of our results is stressed.
Many studies on multisensory processes have focused on performance in simplified experimental situations, with a single stimulus in each sensory modality. However, these results cannot necessarily be applied to explain our perceptual behavior in natural scenes where various signals exist within one sensory modality. We investigated the role of audio-visual syllable congruency on participants? auditory localization bias or the ventriloquism effect using spoken utterances and two videos of a talking face. Salience of facial movements was also manipulated. Results indicated that more salient visual utterances attracted participants? auditory localization. Congruent pairing of audio-visual utterances elicited greater localization bias than incongruent pairing, while previous studies have repor...
Subcutaneous involvement frequently occurs in maxillary sinus carcinoma. Radical resection does not include removal of the skin at risk. In standard postoperative wedge-pair treatment plans, the surface dose is dependent upon beam weighting, beam energy, and patient contour. Thermoluminescent dosimetry (TLD) measurements were performed to evaluate the surface dose of patients undergoing postoperative irradiation of maxillary sinus carcinoma following primary resection. When 60 Gy was delivered to isocenter with a 45 degrees wedge pair and 6 MV photons with 1 cm bolus, the subcutaneous tissues at risk received {approximately} 30 Gy. Based upon presented TLD measurements, supplemental electron beam therapy to the subcutaneous tissues if primarily involved should be considered.
This invention pertains to a light weight underground pipe or cable installing device adapted for use in a narrow and deep operating trench. More particularly this underground pipe installing device employs a pair of laterally movable gates positioned adjacent the bottom of the operating trench where the earth is more solid to securely clamp the device in the operating trench to enable it to withstand the forces exerted as the actuating rod is forced through the earth from the so-called operating trench to the target trench. To accommodate the laterally movable gates positioned adjacent the bottom of the narrow pipe installing device, a pair of top operated double-acting rod clamping jaws, operated by a hydraulic cylinder positioned above the actuating rod are employed.
The band crossing in "1"3"2Ba has been investigated by using the interacting boson model. A broken neutron pair has been coupled to a collective boson core. The boson-fermion interaction hamiltonian contains terms which can transform a boson into a pair of quasiparticles and vice versa. The parameters were partly determined by fitting the collective states of "1"3"2","1"3"4Ba and the yrast states of "1"3"1Ba. The energy backbending has been satisfactorily reproduced. Good agreement of the electromagnetic moments has been reached. The structure of the wave functions has been discussed. (author)
We report on a two-photon interference experiment in a quantum relay configuration using two picosecond regime PPLN waveguide based sources emitting paired photons at 1550 nm. The results show that the picosecond regime associated with a guided-wave scheme should have important repercussions for quantum relay implementations in real conditions, essential for improving both the working distance and the efficiency of quantum cryptography and networking systems. In contrast to already reported regimes, namely femtosecond and CW, it allows achieving a 99% net visibility two-photon interference while maintaining a high effective photon pair rate using only standard telecom components and detectors.
We present a method for grouping the synonyms of a lemma according to its dictionary senses. The senses are defined by a large machine readable dictionary for French, the TLFi (Tr\\'esor de la langue fran\\c{c}aise informatis\\'e) and the synonyms are given by 5 synonym dictionaries (also for French). To evaluate the proposed method, we manually constructed a gold standard where for each (word, definition) pair and given the set of synonyms defined for that word by the 5 synonym dictionaries, 4 lexicographers specified the set of synonyms they judge adequate. While inter-annotator agreement ranges on that task from 67% to at best 88% depending on the annotator pair and on the synonym dictionary being considered, the automatic procedure we propose scores a precision of 67% and a recall of 71%. The proposed method is compared with related work namely, word sense disambiguation, synonym lexicon acquisition and WordNet construction.
Given a set of users, their friend relationships, and a distance threshold per friend pair, the proximity detection problem is to find each pair of friends such that the Euclidean distance between them is within the given threshold. This problem plays an essential role in friend-locator applications and massively multiplayer online games. Existing proximity detection solutions either incur substantial location update costs or their performance does not scale well to a large number of users. Motivated by this, we present a centralized proximity detection solution that assigns each mobile client with a mobile region. We then design a self-tuning policy to adjust the radius of the region automatically, in order to minimize communication cost. In addition, we analyze the communication cost of our solutions, and provide valuable insights on their behaviors. Extensive experiments suggest that our proposed solution is efficient and robust with respect ...
Thinning and burning forests established on revegetated mine pits in jarrah (Eucalyptus marginata) forests of south-west Australia is being considered as a management option to accelerate succession in sites with excessive tree densities. To assess the impact of thinning and burning on reptiles and small mammals, we installed trapping grids in eight thinned and burned sites, each paired with untreated controls. Of the eight pairs, four were in rehabilitated sites (planted with nonlocal species) and four were in restored sites (seeded with local species). Thinning and burning had no significant impact on the small mammal community, although Cercatetus concinnus was more abundant in rehabilitated sites. In contrast, thinning and burning significantly increased reptile abundance and species r...
A dielectric-wall linear accelerator is improved by a high-voltage, fast rise-time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators. A high voltage is placed between the electrodes sufficient to stress the voltage breakdown of the insulator on command. A light trigger, such as a laser, is focused along at least one line along the edge surface of the laminated alternating layers of isolated conductors and insulators extending between the electrodes. The laser is energized to initiate a surface breakdown by a fluence of photons, thus causing the electrical switch to close very promptly. Such insulators and lasers are incorporated in a dielectric wall linear accelerator with Blumlein modules, and phasing is controlled by adjusting the length of fiber optic cables that carry the laser light to the insulator surface.
A dielectric-wall linear accelerator is improved by a high-voltage, fast rise-time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators. A high voltage is placed between the electrodes sufficient to stress the voltage breakdown of the insulator on command. A light trigger, such as a laser, is focused along at least one line along the edge surface of the laminated alternating layers of isolated conductors and insulators extending between the electrodes. The laser is energized to initiate a surface breakdown by a fluence of photons, thus causing the electrical switch to close very promptly. Such insulators and lasers are incorporated in a dielectric wall linear accelerator with Blumlein modules, and phasing is controlled by adjusting the length of fiber optic cables that carry the laser light to the insulator surface. 12 figs.
By using the paired comparison methodology, it was possible to establish evaluative priorities, providing criterion weights which reflected the thoughts and feelings of an advisory committee consisting of experts in the task selection process. For the U.S. Army Infantry School, the weights can be used to stress higher weighted criterion results in the task selection process. By extending the size and diversity of the advisory committee, the use of paired comparison methodology can provide an effective, reliable procedure for (1) constructing evaluative criterion weights for the task selection process and in other areas which have multiple criteria used for evaluative purposes and (2) incorporating into an evaluative design the valuable contributions of various experts and interest groups. (Author/BW)
We have studied the vibrational properties of the filled tetrahedral semiconductor LiMgAs and its binary analog AlAs by using the plane-wave pseudopotential method within density functional theory. The calculated lattice constants for the studied compounds are in good agreement with previous theoretical and experimental results. The phonon dispersion curves and phonon density of states are calculated by using density functional perturbation theory. The sound speeds in different directions are quantitatively similar in LiMgAs and AlAs. The assignment of the zone center modes to the relative motion of the atoms shows that the lower optic modes are due to the Mg-As pair vibrations, while for the upper ones the Li-Mg pair dominates, which is attributed to the smaller Mg atom mass. The longitudinal interatomic force constant of Mg-As is about 66% higher than that of Li-As, showing the relatively high covalency of the former bond.
In this paper we present an approximation method for the convolution of two planar curves using pairs of compatible cubic B?zier curves with linear normals (LN). We characterize the necessary and sufficient conditions for two compatible cubic B?zier LN curves with the same linear normal map to exist. Using this characterization, we obtain the cubic spline approximation of the convolution curve. As illustration, we apply our method to the approximation of a font where the letters are constructed as the Minkowski sum of two planar curves. We also present numerical results using our approximation method for offset curves and compare our method to previous results.
Spectroscopy based on the Andreev reflection (AR) process at the interface between the normal metal tip and the superconductor has become one of the very successful methods for studies in novel exotic superconductors. The method is capable to address the size, symmetry as well as multiplicity of the superconducting order parameter. The method provided one of the first evidences of the two-gap superconductivity in MgB{sub 2} with a detailed temperature dependence of the both gaps. A theory treating the Andreev reflection spectroscopy in the mixed state is missing. We analyse the AR spectra of MgB{sub 2} in the mixed state via modelling the magnetic pair-breaking by the increasing spectral broadening parameter {gamma}. As a result a non-trivial pair breaking effect in the {pi}-band is found.
Ab initio planewave pseudopotential method is used to study carbon diffusion and pairing in crystalline silicon. The calculation is performed with a 40 Ry planewave cutoff and 2x2x2 special k-point sampling with a supercell of 64 atoms. It is found that substitutional carbon attracts interstitial Si forming a <001> C interstitial with a large binding energy of 1.45 eV. The interstitial carbon is mobile and can migrate with a migration energy of 0.5 eV. The interstitial carbon can bind further to another substitutional carbon forming a substitutional carbon-interstitutional carbon pair with a binding energy of 1.0 eV. This model is used to understand the effect of high C concentration on the transient enhanced diffusion in Si.
The pair-specific ground state energy of Newtonian N-body systems grows monotonically in N. This furnishes a whole family of simple new tests for minimality of putative ground state energies obtained through computer experiments. Inspection of several publically available lists of such computer-experimentally obtained putative ground state energies has yielded several dozen instances which failed (at least) one of these tests. Although the correct ground state energy is not revealed by this method, it does yield a better upper bound on it than the experimentally found value whenever the latter fails a monotonicity test. The surveyed N-body systems include in particular N point charges with 2- or 3-dimensional Coulomb pair interactions, placed either on the unit 2-sphere or on a 2-torus (a.k.a. Thomson, Fekete, or Riesz problems).
This paper presents results from a research case study that examined the distribution of travel time of origin-destination (OD) pairs on a transportation network under incident conditions. Using a transportation simulation dynamic traffic assignment (DTA) model, incident on a transportation network is executed under normal conditions, incident conditions without traveler information availability, and incident conditions assuming that users had perfect knowledge of the incident conditions and could select paths to avoid the incident location. The results suggest that incidents have a different impact on different OD pairs. The results confirm that an effective traveler information system has the potential to ease the impacts of incident conditions network wide. Yet it is also important to n...
The titers of several preparations of kuru. Creutzfeldt-Jacob disease, and scrapie viruses were reduced by only 1/10th or less by high doses of gamma radiation of 50 kGy and by only 1/10th-1/1000th...Full Text Available
A total dose hardening treatment is applied to SIMOX buried oxides. Total ionizing dose radiation testing is performed on fully-depleted transistors fabricated on both hardened and non-hardened substrates. At 200 krads x-ray dose, the front gate shift is reduced from -0.7 to -0.2 V for FETs built on the hardened wafers.
A new channel of nonlinear ionization of quantum system in a strong laser field is discussed. The probability of spontaneous radiation decay from the ground state in a short-range potential to the final Volkov wave function, is calculated by the first order of the perturbation theory. It is shown that this process at high intensities of the laser field will be comparable with the high harmonic generation. (orig.)
Exposure of teachers of physics to X-radiation emitted by instruments which are used for demonstrating rarefied gas discharges during physics lessons at secondary schools is discussed. The measurements performed provide an explicit evidence that an effective, annual exposure dose under the most unfavorable conditions does not exceed admissible levels according to Polish regulations pertaining to persons non-occupationally exposed to ionizing radiation. (author). 3 refs,1 fig.
The paper deals with a model in which the motion of a gas in plasma accerators and high-curent discharges in the present of a skin effect is treated as expulsion by a 'magnetic piston' under the action of surface current flow. Specifically examined is the situation where the initial gas pressure is negligible in comparison with the magnetic pressure, and the motion of the gas may be treated as a self-simulating one. A system of hydrodynamic equations of the problem is derived and integrated by Adam's method. Results are plotted and discussed.
We discuss optimal detection of fast radio transients from astrophysical objects while taking into account the effects of propagation through intervening ionized media, including dispersion, scattering and scintillation.Our analysis applies to the giant-pulse phenomenon exhibited by some pulsars, for which we show examples, and to radio pulses from other astrophysical sources, such as prompt radio emission from gamma-ray burst sources and modulated signals from extra-terrestrial civilizations.
Room air quality and thus thermal comfort for the occupiers in closed spaces depend on several factors: temperature and humidity of the air, temperature of the surrounding surfaces, content of foreign matter of the air, acoustical perceptions, electric fields and ions as well as colours and light. Air humidification, cleaning and ionization largely contributes to improved room air quality. The article goes into problems of too dry and polluted air as well as into measures with which these problems can be solved. (BWI).
It may be necessary to reduce microbiological contamination of crude drugs (medicinal plants or their parts like roots, leaves, flowers). This can be done by treating the drugs with ionizing radiation. Meethods for detection of such an irradiation were developed. It could be pointed out that measurements of luminescence, viscosity and electron spin resonance were suitable for specific drugs, but not for all drugs. (orig.).
Food irradiation is the process of exposing food to an ionizing energy to kill harmful bacteria and other organisms and extend shelf-life. It is a safe process and has been approved by some 50 countries worldwide and applied commercially in the USA, Japan, China and several European countries for many years. Trends law regulations and new applications in Europe and another countries has been described. (author)
An introduction is presented on the radiation hazards connected with biomedical radiography and nuclear medicine. The frequency of radiodiagnostic efforts was rather high in the Netherlands. This was reduced considerably by abolishing the thorax screening of the population. About diagnostic nuclear medicine less can be said because far fewer numerical data are available. An exposition of genetically and somatically significant doses and how to compute them is given. The drawing up of a profit versus risk evaluation for medical applications of ionizing radiations is recommended. (Auth.).
Much of the material presented in this book derived originally from the series ''Physical Processes in Gaseous Nebulae'' initiated at the Harvard College Observatory in the 1930's. The subject of gaseous nebulae, which offers opportunities for studies of stellar evolution, should be of interest to atomic physicists, spectroscopists, plasma experts, and to observers and theoreticians alike for the study of attenuated ionized gases.
Conceptual and factual advances in understanding neuronal migration in the past two decades have provided new insight into the pathogenesis of brain malformations at the cellular, molecular, and functional levels. Some of these results may have direct implications in understanding the consequences of ionizing radiation on the fetal central nervous system in utero. (orig.).
The process of mouse skin tumor formation is subdivided into three operational stages. These stages include initiation, promotion and progression. Ionizing radiation has been found to be a weak initiating agent in the production of malignant squamous cell carcinomas, a complete carcinogen and an agent effective in causing tumor progression. Four skin tumor histologies have been seen with ionizing radiation: benign papillomas, squamous (SCC) and basal (BCC) cell carcinomas and fibrosarcomas. Distinct non-ras transforming genes have been detected in radiation initiated SCCs. A benign papilloma cell line (308) was used as a model system to study ionizing radiation induced progression. A variant 308 cell line (308 10 Gy 5) derived by irradiation of the parental 308 cell has been characterized. The 308 10 Gy 5 cells unlike the parental 308 cells from malignant tumors in athymic nude mice upon subcutaneous injection. The variant ...
A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.
Results are described of the study of the analytical applicability of a highly efficient ion source developed for a mass spectrometer. Its ionizer is in the form of a partially closed cavity with a small aperture for leading out ions, heated to a high temperature. The new ion source increases the sensitivity of the apparatus in operations with transuranium elements by almost two orders of magnitude. It is possible to perform isotopic analyses with a high salt content in the sample, and to study the characteristics of nuclear fuel, even without chemical separation of the sample elements.
Various physics applications involve the computation of the standard hypergeometric function {sub 2}F{sub 1} and its derivatives. Because it is not an intrinsic in the common programming languages, automatic differentiation tools will either differentiate through the code that computes {sub 2}F{sub 1} if that code is available or require the user to provide a hand-written derivative code. We present options for the derivative computation in the context of an ionization problem and compare the approach implemented in the Diamant library to standard methods.
The decree refers to conditions of irradiation of food and its components for radappertization and radurization using gamma radiation from cobalt 60 or cesium 137, X radiation or electron beam up to maximum total medium absorbed dose 10 kGy.
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4? geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon.
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4{pi} geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4#pi# geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).
Late somatic and genetic radiation effects are imperfectly understood, particularly in the human species. However the available information is sufficient to draw reasonably precise risk estimates in man for many types of damage by means of scientifically justifiable procedures and with the necessary caution. This overall absolute risk of major somatic and genetic damage may be set at around 10"-"4/rad of chronic whole-body doses.
The Wannier threshold law for three-particle fragmentation is reviewed. By integrating the Schroedinger equation along a path where the reaction coordinate R is complex, anharmonic corrections to the simple power law are obtained. These corrections are found to be non-analytic in the energy E, in contrast to the expected analytic dependence upon E.
Angular wave functions are investigated which describe the motion of two electrons in the field of a nucleus at fixed equal distances from electrons to the nucleus. Calculation methods are considered that include matching of power series and expansion in series of Legendre polynomials. Asymptotic properties of solutions at small large distances are determined.
A simple and continuous model for the on-state current of polysilicon thin-film transistors, suitable for implementation in circuit simulators, is presented. The model includes the potential barrier at the grain boundaries, the channel length modulation and the excess current due to impact ionization. Comparison between measured output characteristics and the model shows excellent agreement over wide range of bias voltages and for devices with different gate lengths.
The most striking achievement in magnetic fusion experiments during last few years was the discovery of plasma detachment from material targets, a much needed effect for plasmas with high power fusion parameters. Due to the very low heat loads on the targets observed in these regimes and potentially low erosion of the targets, detached regimes look attractive from the International Thermonuclear Experimental Reactor (ITER) design point of view. Thus the author has experimental proof for the possibility for a co-existence of fusion relevant hot plasma in the core and a low temperature partly ionized plasma at the edge of magnetic fusion device. Although somewhat similar behavior of edge plasma was considered theoretically even before plasma detachment was found experimentally, it was not clear in the beginning how these theoretical and experimental findings would fit together. Now, after a few years of intensive additional experimental and theoretical studies, a ...
Tunneling spectroscopy of normal-insulator-superconductor junction is investigated theoretically. In anisotropic superconductors, differently from the case of isotropic superconductor, the effective pair potentials felt by quasiparticles depend on the direction of their motion. By taking this effect into account, it is shown that the conductance spectra strongly depend on the crystal orientation. Using Green`s function method, local density of states (LDOS) in superconductor is also calculated. The close relation between conductance spectra and LDOS is presented. The calculation is compared with experimental spectra of high-{Tc} superconductors.
BackgroundThe association between infertility and sperm disomy is well documented. Results vary but most report that men with severely compromised semen parameters have a significantly...Full Text Available
I report on a lattice computation of the energy of a system of two light quarks and two static antiquarks as a function of the separation of the static antiquarks. In terms of hadrons such a system corresponds to a pair of B mesons and its energy to the hadronic potential. I present selected results for different isospin, spin and parity combinations of the individual B mesons mainly focusing on those channels relevant to determine, whether two B mesons may form a bound tetraquark state.
Radial distribution functions of liquid sodium and caesium at 100"0C have been calculated by the method of molecular dynamics with interionic pair potentials derived from Heine-Abarenkov-Shaw type model potential. The results were found to be in good agreement with recent experimental data. (Auth.).
The e/sup -/..-->..e/sup -/(..nu..nu-bar) process in the field of a circularly polarized plane wave is studied in the framework of the Glashow-Weinberg-Salam model. General expressions for the probability of creation of neutrino pairs are obtained, and the case of a low-intensity wave is studied in detail. The effects of asymmetry of emission of electron and muon neutrinos are estimated, and comparison with previous results is performed.
A model for generating the observed cosmic-ray antiproton spectrum in plasma consisting mainly of electron--positron pairs (n/sub plus-or-minus//n/sub p/> or approx. =10) is discussed. Coulomb collisions in the plasma would cause additional energy losses, significantly enhancing the antiproton flux at energies < or approx. =1 GeV. The computed p-bar/p ratio satisfactorily fits the observations.
The relations between nuclear energy availability and nuclear plant safety are analyzed in the particular cases of naval propulsion nuclear boilers (aircraft carriers, submarines): safety objectives, present and potential risk analysis, optimization of the availability-safety couple, at the design stage and during operation (procedural rules related to the boiler state, real time decisions). 6 fig., 1 tab.
A 13.1-kb DNA fragment carrying Pseudomonas denitrificans cob genes has been sequenced. The nucleotide sequence and genetic analysis revealed that this fragment contained five different cob genes named...Full Text Available
A model of formation of cosmic ray antiproton spectrum in plasma consisting mainly of electron-positron pairs (nsub(+-)/nsub(p) > or approximately 10) is considered. Additional energy losses due to Coulomb collisions in plasma provide significant increase of the antiproton flux in the energy range < or approximately 1 GeV. Calculated anti p/p ratio is in a satisfactory agreement with the observational data.
...Project objectives to restore/create network of secure lapwing breeding sites to provide conservation management advice to planners, developers and land managers to raise awareness of lapwing conservation issues in the local areaKey dates so far First pair of lapwing breeding at Parc Bryn Bach, mitigation site for loss of a nearby large lapwing breeding colony, in May 2008Work planned or underway Continued working with developers and landowners to ...
Muon captures by nucleon pairs via meson-exchange currents produce a high energy excitation tail in heavy nuclei. The muon induced fission by these excitations is calculated in several subactinide nuclei with high threshold fission barriers. The probability for delayed fission ranges from 4 x 10"-"5 to 4 x 10"-"3 for the isotopes considered. (orig.).
The hierarchy of integrable nonlinear equations associated with the quadratic bundle is considered. The expressions for the solution of linearization of these equations and their conservation law in the terms of solutions of corresponding Lax pairs are found. It is shown for the first member of the hierarchy that the conservation law is connected with the solution of linearized equation due to the Noether's theorem. The local hierarchy and three nonlocal ones of the infinitesimal symmetries and conservation laws explicitly expressed through the variables of the nonlinear equations are derived. (author)
The indirect detection of particle dark matter (DM) is based on the search for anomalous components in cosmic rays (CRs) due to the annihilation of DM pairs in the galactic halo, on the top of the standard astrophysical production. These additional exotic components are potentially detectable at Earth as spectral distortions for the various cosmic radiations: $\\chi + \\chi \\to q \\bar{q}, W^+ W^-, ... \\to \\bar{p}, \\bar{D}, e^+ \\gamma and \
The research of the CELLO collaboration is reviewed. After a description of the CELLO detector tests of QCD and hadronic final states by determination of the strong coupling constant and studies of inclusive production of electrons and muons in multihadronic events in e"+e"- annihilation are described. Then studies of deep inelastic e#gamma# scattering with lepton pair production and the study of the structure function of the photon are briefly described. Finally studies on QED processes are described together with tau decays. (HSI).
Recent observations of the evolutionary properties of paired and interacting galaxies are reviewed, with special emphasis on their global emission properties and star formation rates. Data at several wavelengths provide strong confirmation of the hypothesis, proposed originally by Larson and Tinsley, that interactions trigger global bursts of star formation in galaxies. The nature and properties of the starbursts, and their overall role in galactic evolution are also discussed.
A ligase chain reaction assay based on a single-base-pair difference in the V9 region of the 16S rRNA gene (16S rDNA) was developed to distinguish between Listeria monocytogenes and other Listeria species....Full Text Available
Cystic fibrosis (CF) is a monogenic disease characterized by a high variability of disease severity and outcome that points to the role of environmental factors and modulating genes that shape the course...Full Text Available
Over 7000 events containing a fully reconstructed D{bar D} pair have been extracted from data recorded by the FOCUS photoproduction experiment at Fermilab. Preliminary results from a study of correlations between D and {bar D} mesons are presented. Correlations are used to study perturbative QCD predictions and investigate non-perturbative effects. We also present a preliminary result on the production of {psi}(3770).
Experiments were carried out to determine the adsorption capability of some commercial activated and non-activated charcoal samples with methanol to select the most favourable pair to be used in a solar adsorption refrigeration system. The results obtained are presented. A simple method has been used to enhance the adsorption capability of the lumpwood charcoal. (Author)