Efforts have been made to develop fuel cell powered EVs (electric vehicles) in several countries and to demonstrate its high potential. Since 1990 fuel cell research has been conducted at FUT (the Fukui University of Technology) beginning with PAFC. Research effort is now being focused upon the application of fuel cells to the EV drive as this technology shows great future potential, particularly in the area concerning environmental protection. PEFC (Polymer Electrolyte Fuel Cell) has been chosen as the fuel cell for the EV power source because it possesses an inherent high power density and it also has another important feature; operation can be started under ambient temperature without preheating. The principal objective of this research is to pursue the optimum system of a PEFC drive EV. The size of the prototype vehicle in the university project is limited to a certain range and the capacity of the ...
The manual presents the fundamentals of thermodynamics and fluid mechanics, the main components of steam powerplants, and the power generation process. The following concepts and subjects are discussed at length: steam generator; steam turbines; turbogenerators; condensers; cooling technology; water/steam cycle and water treatment; design data of fossil-fuelled powerplants; design and optimisation of nuclear powerplant thermodynamics; pipelines and fittings; control systems in steam powerplants; connection to the electricity grid and self-supply of thermal powerplants; powerplant transformer concepts and definitions. (HAG).
This is a manuscript for a lecture contents: 1. Steam power and fundamentals of the steam power process, 2. conventional, nuclear and other steam generation processes, 3. cooling systems for steam powerplants, 4. gas turbine powerplants and combined-cycle powerplants, 5. cogeneration, 6. development of thermal powerplants and environmental effects. (orig.).
This is a manuscript for a lecture contents: 1) Steam power and fundamentals of the steam power process, 3) conventional, nuclear and other steam generation processes, 4) cooling systems for steam powerplants, 5) gas turbine powerplants and combined-cycle powerplants, 6) cogeneration, 7) development of thermal powerplants and environmental effects. (GL).
All powerplant engineers face the problem of peak power demands. Pumped storage plants are used to generate peak load power by pumping up water utilizing off-peak energy of hydrothermal and thermonuclear plants. This is the first accessible text/reference to cover hydroelectric power generation with emphasis on engineering to meet peak power demands by means of pumped storge plants, tidal powerplants, and low head power generation. Text covers hydrology, mechanical and electrical equipment, accessories such as penstocks and valves, and civil engineering considerations. Contains descriptions of several existing plants. Includes 200 diagrams and 50 photographs.
All powerplant engineers face the problem of peak power demands. Pumped storage plants are used to generate peak load power by pumping up water utilizing off-peak energy of hydrothermal and thermonuclear plants. This is a reference to cover hydroelectric power generation with emphasis on engineering to meet peak power demands by means of pumped storage plants, tidal powerplants, and low head power generation. Text covers hydrology, mechanical and electrical equipment, accessories such as penstocks and valves, and civil engineering considerations. Contains descriptions of several existing plants. Includes 200 diagrams and 50 photographs.
Some general topical information (generating capacity and electric power generation, development and structure of electric power consumption, frequency and peak load, exchange of electricity) is followed by an account of the situation of coal-fired powerplants, hydroelectric powerplants and nuclear powerplants, and a brief discussion of the environmental situation (emissions and wastes, immissions, and air pollution abatement measures for powerplants). (orig./UA).
... Treatment of electrical systems for pumped storage plants is not covered in the manual, although much of the information is applicable to pumped ...
The article presents briefly the plans of the British Petroleum Oil Company for a new hydrogen powerplant that includes an offshore platform in the North Sea.
Data on French nuclear electricity generation sites, nuclear powerplant operations personnel, operation simulators, nuclear training centers and training statistics are presented.
After that power fluctuations had occurred at Borssele nuclear power station it was decided to install a power system stabilizer. This stabilizer shall reduce the unwanted power fluctuations. The preliminary research and the results of measurements carried out during commissioning are described. (J.C.R.)
Due to development of electric power system and considering an increase of electrical energy consumption, needs for larger units in new powerplants are obvious. Connection of large nuclear powerplants to the grid, depending on their power and location, usually requires significant investments in transmission network development and construction. Considering the capacity of the 400 kV transmission network in Croatia, this problem is evident. This paper deals with the possibilities of nuclear powerplants construction, as one possible option in electric power system development, and their interconnection to the electricity grid. (author).
In Hungary, legislation for nuclear powerplants was developed at the end of the 1970s, among which is the quality assurance code for nuclear powerplants. Hungarian practice is presented, including discussion of the requirements for quality assurance, qualification of the suppliers and inspection practices. The general requirements of quality assurance in the course of construction of a nuclear powerplant are presented: quality assurance of technological equipment, fuel, electrical equipment, automatic instrumentations, building structures and technology.
The general requirements applicable to the quality assurance of the Finnish nuclear powerplants are presented in the Council of State Decision (395/91) and in the guide YVL 1.4. This guide specifies the quality assurance requirements to be applied during the operation of the nuclear powerplants as well as of the other nuclear facilities. Quality assurance applies to all the activities and organizations with a bearing on the safe operation of the nuclear powerplants. (5 refs.).
Originally designed exclusively for peak load covering, pumped storage plants are now faced with new challenges brought about by the deregulation of the electricity market and the substantial growth of wind power capacity. Today's pumped storage plants are started more frequently and often for shorter periods of time. The grid controlling tasks have increased the importance of the role played by this type of powerplant and improved sales considerably. But the operational demands have grown substantially as well. This paper discusses the ensuing adaptation of powerplant operation as well as options available to powerplant operators. (orig.)
Despite the fact that there is still a potential to improve the efficiency of classic brown coal powerplants by various measures from 36% to approx. 40-41%, the essential big increase of the efficiency to values of approx. 46% can only be achieved by the transition to combined gas and steam turbine processes. This means for the solid fuel brown coal that a gasification is integrated into the powerplant process. The combined cycle powerplant with an integrated brown coal gasification represents this new powerplant concept. The applied High Temperature Winkler method (HTW-method) is an advancement of the Winkler method that works at environmental pressure and was developed by the Rheinbraun AG. (orig./DG).
Stretch-Out and Extended Low Power Operation is two particular operating modes applied for nuclear electricity generation. The relevant safety analysis and the impacts on plant operation are well illustrated, as well as some operation experiences earned in Daya Bay nuclear power station. The safety analysis and plant practice show that Stretch-Out operation and Extended Low Power Operation are operable in Daya Bay nuclear power station
The invention concerns a procedure for operating reactors in nuclear powerplants. It aims at utilizing power reserves in nuclear powerplants. This can be achieved by a steam-side connection of the steam generators of two reactors. The amount of steam exchanged between the units is chosen in such a way that power changes at the steam turbines feedback mainly to the corresponding reactor. In order to realize a high power transfer it is necessary to return the amount of condensate produced in the steam receiving unit and corresponding to the power transferred to the feedwater system of the steam donating unit.
Electrical power is generated by steam turbines (steam being produced by coal, oil, gas or nuclear reactors), hydro units, gas turbines, internal combustion engines, jet engines, and pumped storage plants. Nuclear PowerPlants generate only 15% of the total electrical power in the US. Nuclear PowerPlants being cheaper to run are generally base loaded. The pumped-storage and gas turbine plants have ideal characteristics for peaking duty. In the pumping mode, pumped storage plants are used to provide additional system load and in the generating mode, they supply reactive power during peak load demands. Gas turbine plants have higher running costs, but are used as peaking units with a fast start capability. Fossil power ...
Deregulation and restructuring changes in the electric power industry have provided opportunities to build new powerplants. These powerplants, however, will not enjoy long-term power purchase agreements with the utilities they serve, but will have to respond to the market. This is where the term `merchant plant` originates. Calpine Corp. presented its reasons for believing that now is the best time to be building new merchant plants based on modern natural gas-fired, combined-cycle powerplants. Among those reasons are: (1) construction of new nuclear powerplants has been rejected by people on both sides of the border, (2) attempts to promote alternative energy sources such as solar, wind and biomass have not added significant ...
Due to changed operational conditions and because of the increasing age of several hydro powerplant components, there is an increasing risk of damages and the control of degradation mechanisms is of increasing significance. Therefore lifetime considerations for safety relevant components in pumped-storage plants become more and more important. The development of a lifetime management system, in conjunction with monitoring systems and specific surveillance for a group of pumped-storage powerplants of different ages and in a wide range of power output is presented. The special focus is on the impact of fatigue strength considerations within this framework. The applied procedure will be described for typical mechanical components in pumped-storage plants exemplarily. (orig.)
Ways of improving the water chemistry used in the turbine generator stator?s cooling systems at Russian nuclear powerplants are considered. Data obtained from operational chemical monitoring of indicators characterizing the quality of cooling water in the turbine generator stator cooling systems of operating power units at nuclear powerplants are presented.
Project management mode plays a key role in project construction, especially in nuclear power field. From the aspects of right, responsibility and benefit, this paper discussed the differences among the common used project management modes. Also the main kinds of the construction management modes used in China's nuclear powerplants were summarized. At last, considering the experience of Ningde nuclear powerplant, this paper put forward several perspectives about the selection of project management mode in nuclear powerplant construction. (authors)
Research in concentrated thermal solar powerplants of all types and, in particular, those based on central receiver, namely solar tower plants, has experienced great impetus in the last decade, reaching full commercial operation with the PS10 plant in Spain. In spite of previous demonstration plants testing different receivers and power cycle layouts, this first commercial powerplant adopted a cavity receiver generating saturated steam and therefore penalising cycle efficiency in order to gain plant reliability. According to the experience gained, if a competitive Levelised Cost of Electricity is to be reached, capital and maintenance costs must be reduced and efficiencies must be increased. To achieve these goals, modifying the power cycle is deemed essential, whether using ...
This work presents the project and relates the implementation of a power system stabilizer in Itauba hydroelectric powerplant, Brazil. Some forecasts and field experiments are also presented. 10 refs., 19 figs.
The present guidelines supplement the 'VGB guidelines for the reduction of noise in thermal powerplants' with indications for the ordering and quality assurance of the individual noise-producing machines and equipment of powerplant operation. These guides are to simplify the commissioning and delivering for the orderer and deliverer. In addition, these guidelines are to lead to a successful cooperation of all parties in the reduction of the sound radiation. A precondition for this is an explanation of the sound technical demands which must be made on the single machines or mechanical equipment in powerplant systems. A protection of the neighbourhood as well as operational personnel against noise according to the state of technology is to be achieved by a clear form of ordering and quality assurance. The ordering and assurance procedure for all aggregates in ...
This appendix provides a listing of the BNW-I optimization code, MFCIRI, for a metal finned tube dry-cooled heat rejection system for powerplants. (LCL)
Intended to be used in conjunction with ANSI N45.2 and addresses the quality assurance requirements related to subsurface investigations performed prior to the construction of safety related structures of nuclear powerplants.
Requirements for the installation, inspection, and testing that assure the quality of important components of a nuclear powerplant during construction are presented.
This guide describes an acceptable method of complying with the Commission's regulations with regard to the quality assurance requirements for the packaging, shipping, receiving, storage, and handling of items for water-cooled nuclear powerplants.
This article puts the case for coal fired combined cycle gas turbine (CCGT) powerplants. The need to gasify the coal for the CCGT, use of fluidised bed combustors or gasification systems, the difference in prices of coal and natural gas, and coal and natural gas reserves are discussed. (UK)
The installation procedure, the fabrication, fitting up, positioning, adjustment and welding of piping, examinations, hydrostatics testing and insulation of piping for reactor primary circuit piping of Daya Bay Nuclear powerPlant are briefly described.
This standard provides the general requirements used in the design, construction, testing, and commissioning of concrete containment structures for CANDU nuclear powerplants designated as class containment and is directed to the owners, designers, manufacturers, fabricators, and constructors of the concrete components and parts.
Outage is a specific period of time for radiation protection in a nuclear powerplant, in which the radiation risk and collective dose are both at the highest level. In this article, the practice and experience of occupational exposure control in the outages of Daya Bay Nuclear PowerPlant are introduced through following aspects: early involvement in outage preparation by radiation protection service, control of source term, radiation protection and safety management in the outage implementation processes, the effectiveness of the plant's safety management network and overall involvement of all staffs of the plant, experience feedback and continuous improvement in radiation protection management, etc
The paper deals with the exploitation of the pumped storage plants for the control of the Slovak power system. For that purpose current utilization of pumped storage plants currently in operation was analyzed from the point of view of their part in the operation control of the Slovak power system. The aim of this analysis was to exploit knowledge gained so far for the future outlook up to the year 2010, including the evaluation of the need to construct pumped storage plant Ipel with a weekly storage cycle. (author).
Future powerplants will be more fuel efficient, environmentally benign, and economical than current powerplants. A high performance power system (HIPPS), based on a coal-fired combined cycle, is currently being developed. The corrosion and temperature-strength properties of currently available metallic materials limit the maximum efficiency of this cycle. Recently, ceramic matrix composites have shown promise in overcoming the design limitations on the future powerplants. In particular, the high-temperature, and corrosion and erosion resistant properties of continuous fiber ceramic composites (CFCCs) will allow engineers to design high-temperature heat exchangers, cyclone vortex finder tubes, and other components. Research being performed to evaluate candidate materials for use in future power ...
Discusses the resolution of the 2. Congress of the Polish Nuclear Society on the energy situation in Poland and recommendations for energy policy. Recommendations for use of nuclear powerplants in Poland are made considering environmental pollution from coal combustion (air pollution by sulfur dioxide, nitrogen oxides and carbon dioxide as well as water pollution by salt from mine water discharged to rivers), development of the Polish economy, forecast increase in energy consumption and the role of nuclear energy in other European countries. Research on nuclear powerplants, safety and environmental aspects as well as comparative efficiency of coal-fired powerplants and nuclear powerplants is evaluated.
The potential public safety impacts from accidents in conceptual fusion powerplants were investigated. Fusion was found to have some potential for accidents, as does any energy generating system. Functions of fusion powerplants were identified that possess sufficient potential for an accidental release of toxic materials to the environment. An assessment was made of the impact of the potential accidents and recommendations are included for R and D that will allow incorporation of safety concerns in fusion powerplant design. This work was based on a review of information available in conceptual design documents of fusion reactor systems.
The potential public safety impacts from accidents in conceptual fusion powerplants were investigated. Fusion was found to have some potential for accidents, as does any energy generating system. Functions of fusion powerplants were identified that possess sufficient potential for an accidental release of toxic materials to the environment. An assessment was made of the impact of the potential accidents and recommendations are included for R and D that will allow incorporation of safety concerns in fusion powerplant design. This work was based on a review of information available in conceptual design documents of fusion reactor systems.
Corrosion is increasingly becoming an important factor reducing the reliability of many nuclear powerplant components. The significance is evaluated of corrosion phenomena with respect to the reliability of primary circuit components of LWR's, viz., the reactor pressure vessel, primary piping, steam generator, and fuel elements. The mechanism of corrosion phenomena is explained and methods of minimizing their effects are presented. An analysis is made of the needs to solve the corrosion problems of nuclear powerplants from the point of view of Czechoslovak producers and research and development activities. International cooperation is reviewed and main problems are formulated on which the solution of corrosion problems of structural materials used in WWER type nuclear powerplants should be focussed. (author).
The demand for cogeneration plants is growing worldwide. For the combination of electricity generation and heat extraction in power stations facilitates an excellent fuel exploitation and makes the operator of the plant independent from external energy suppliers. (orig.)
This paper evaluates a new power tower concept that offers significant benefits for commercialization of power tower technology. The concept uses a molten nitrate salt centralreceiver plant to supply heat, in the form of combustion air preheat, to a conventional combined-cycle powerplant. The evaluation focused on first commercial plants, examined three plant capacities (31, 100, and 300 MWe), and compared these plants with a solar-only 100-MWe plant and with gas-only combined-cycle plants in the same three capacities. Results of the analysis point to several benefits relative to the solar-only plant including low energy cost for first plants, low capital cost for first plants, reduced risk with respect to business ...
This paper focuses on the application and features of a unified multi-machine train condition monitoring and diagnostic system as applied to a 340 MW repowered combined cycle powerplant. Modifications during repowering of the plant required the addition of gas turbines, and design changes to the boiler and steam turbine. Operational procedure during startup also had to be developed. In order to improve the economics of operation, enhancement of both plant operational efficiency and availability were required. Thus it was decided to implement an on-line plant-wide multi-machine Condition Monitoring System. In this paper, the details of the condition monitoring system and some of the design details of the powerplant are presented. Requirements of a condition monitoring system applicable to a combined cycle plant are also ...
Design process of steam generator and condenser at Russian nuclear powerplant type WWER-1000 is identified. The four chapter of the books are organized as nuclear powerplant, types of steam generators specially horizontal steam generator, process of steam generator design and the description of condenser and its process design.
This article examines the developing market for independent power projects in Canada. The topics of the article include bidding in Ontario, the Quebec market, powering British Columbia, and market forces at work in Canada. Discussed are current projects in all stages of completion from bidding to production and includes gas-fired cogeneration, gas-fired combined-cycle electricity generation and cogeneration, wood-waste fired plants, repowering of existing utility plants, and hydroelectric powerplants.
Nuclear options for electricity generations are assessed in this paper. Probabilistic (stochastic) method is used for economic comparison of nuclear powerplants, wind plants and natural gas fired plants. Optimal nuclear powerplant size is also discussed. IRIS is presented as a representative of small and medium reactors
The operating histories and performance of a large (180 MWsub(e)) central condensing plant and five small (5 MWsub(e)) wellhead backpressure powerplants are presented. The thermodynamic performance of the central plant is compared with an estimated possible performance based upon the work of Michaelides. Both types of plant have been shown to be reliable despite some problems due to the contaminants which are associated with geothermal steam.
The aim of this report is to describe the present situation regarding biomass utilization in small powerplants, 0.5 - 20 MW fuel power. Also discussed are the most important technical, economical and environmental conditions which may prevent a fast expansion of small biomass fueled powerplants for generation of district heating in smaller networks and also for electric power generation. Biofuels means a reduction of the net emission of carbon dioxide, but emission of other compounds are not very well known for this size of powerplants. There are only a few biofueled powerplants in Sweden and only a couple with less than 20 MW power supplied. New concepts are under development but not much have been achieved during the most recent years. 25 refs, 10 figs, ...
Inertial Electrostatic Confinement (IEC) fusion was recently described by an Electric Power Research Institute (EPRI) review panel as potentially leading to a most attractive fusion reactor from a utility point of view, if the physics issues can be resolved. Consequently, a design for a small 25-MW electric D-"3He fueled powerplant has been explored. Key powerplant components consist of the IEC, direct energy conversion and a step-down converter for electrical power transmission. (author).
The document gives statistics on the pollutive emissions from Danish powerplants during the period 1987-1996, the main pollutants being sulphur dioxide, nitrogen oxides and carbon dioxide. Data on efficiency levels relative to the production of electricity and heating and on the powerplants` contribution to the total emission of CO{sub 2}, NO{sub x}, and SO{sub 2} from energy consumption in Denmark, are presented, and also as corrected for the net import of electricity. Other data on the emission of each of these chemicals by powerplants are presented as factual, and corrected in accordance with the net import of electricity, and as factual per consumed and produced energy unit at the powerplants. Short notes on related Danish legislation are found in addition to information on sources, methods and definitions used ...
A novel approach to the reliability analysis of a power system with both hydro and pumped storage plants is presented in this paper. The proposed method is based on the concept of peak shaving for the hydro and pumped storage units. Different values of the stored energy of the pumped storage units are employed to demonstrate their effect on the generation reliability of a power system. The proposed scheme has been applied successfully to the reliability analysis of Taiwan power system.
The world's fleet of nuclear powerplants is, on average, more than 20 years old. Even though the design life of a nuclear powerplant is typically 30-40 years, it is quite feasible that many plants will be able to operate in excess of their design lives, provided that nuclear powerplant engineers demonstrate by analysis, trending, equipment and system upgrades, increased vigilance, testing and ageing management that the plant will operate safely. In the operation of nuclear powerplants, safety should be always the prime consideration. Plant operators and regulators must always ensure that plant safety is maintained, and where possible enhanced, during a plant's operating lifetime. Nuclear power ...
Adding capacity to coal-fired plants in small increments of an overall integrated program may be the solution to the 10-year lead time required for the construction of a new plant. A preliminary study evaluates the technical and economic feasibility of a modular natural gas and coal-fired combined-cycle powerplant which can be installed in three distinct phases. The plant sizes are suitable for large industrial and utility applications. The Modular Block PowerPlant (MBPP) concept offers the advantages of phase construction, lower capital cost, lower cost electricity, lower air emissions, lower water requirements, and reduced solid waste discharge. Other advantages include part load availability, reduced coal inventory requirements, and easier plant siting. 11 figures, 4 tables.
Large scale steam storage power generation, one of the new energy storage systems for the future of inflexible electric power sources consisting of nuclear and coal powerplants has been studied on the subjects of the systems to be attached to coal and nuclear power units, of the definition of storage efficiency and of the vertical steam storage vessel technology. Steam storage power generation may be hopeful for its higher efficiency similarly defined as of pumped storage plants while high temperature heat storage and the internal structure of large vertical steam storage vessel (accumulator) need to be developed.
Large scale steam storage power generation, one of the new energy storage systems for the future of inflexible electric power sources consisting of nuclear and coal powerplants has been studied on the subjects of the systems to be attached to coal and nuclear power units, of the definition of storage efficiency and of the vertical steam storage vessel technology. Steam storage power generation may be hopeful for its higher efficiency similarly defined as of pumped storage plants while high temperature heat storage and the internal structure of large vertical steam storage vessel (accumulator) need to be developed. (author).
This study examined the feasibility of using triticale straw for production of electricity in Canada. Triticale is a manmade hybrid of wheat and rye and it has a high potential of growth in Canada. The cost ($/MWh) of producing electricity from triticale straw was estimated using a data intensive techno-economic model. The study also determined the optimum size of a biomass powerplant (MW) which is a trade-off between capital cost of the plant and transportation cost of biomass. Cost curves were also developed in order to evaluate the impact of scale on power production costs. The location of the powerplant and the future expansion of triticale were among the factors considered in the techno-economic mode. The scope of the work included all the processes beginning with the collection of straw to the conversion to electricity through direct combustion at the ...
The proceedings include the following lectures: Facing the challenges - new structures for electricity production. Renewable energies in Europe - chances and challenges. Nuclear outlook in the UK. Sustainable energy for Europe. Requirements of the market and the grid operator at the electricity production companies. Perspectives for the future energy production. Pumped storage plants - status and perspectives. Nuclear power/renewable energies -partners or opponents? New fossil fired power stations in Europe - status and perspectives. Nuclear energy: outlook for new build and lifetime extension in Europe. Biomass in the future European energy market - experiences for dong energy. Meeting the EU 20:20 renewable energy targets: the offshore challenges. DESERTEC: sustainable electricity for Europe, Middle East and North Africa. New powerplants in Europe - a challenge for project and ...
The liberalization of the electricity sector requires utilities to develop sound operation strategies for their powerplants. In this paper, attention is focused on the problem of optimizing the management of the thermal powerplants belonging to a strategic producer that competes with other strategic companies and a set of smaller non-strategic ones in the day-ahead market. The market model suggested here determines an equilibrium condition over the selected period of analysis, in which no producer can increase profits by changing its supply offers given all rivals' bids. Powerplants technical and operating constraints are considered. An iterative procedure, based on the dynamic programming, is used to find the optimum production plans of each producer. Some combinations of powerplants and number of producers are ...
In June 2010, Basic Energy Plan was approved in a Cabinet meeting. It says that Japan aims to construct more than 14 atomic powerplants by 2030. Today, there are 12 plans of construction of atomic powerplant, but it is hard to say that their plans easily come off. That's because public acceptance of atomic powerplant is low in Japan, for example local residents wage opposition campaigns. This study conducts a survey in the form of a questionnaire and analyzes it by Analytical Hierarchical Process (AHP). Analytic Hierarchy Process is a structured technique for dealing with complex decisions. A questionnaire using AHP is very easy to answer and analyze. This survey was conducted in 2 areas. First area is Hohoku-cho, Yamaguchi Pref. that had a plan of construction of atomic powerplant and the plan was demolished by ...
The reduction of emission from powerplants of the public power industry inevitably leads to more and more residual products being obtained which require utilization. Traditionally, the building and building materials industry as well as, for a number of years, the gypsum industry have been the main customers processing these residual materials. To avoid having to tip them at landfills that are in short supply already, further uses are sought; so, for instance, in farming to ameliorate soil and fertilize plants. Relative to this subject, proposals are already available which are presented as lectures at the conference and discussed, together with practical knowledge and new investigation results. (BBR).
The US New Source Review (NSR) program requires powerplant owners to install modern pollution control whenever they upgrade their plants in a way that will cause more pollution. The Clean Air Task Force and other environmental organizations and dozens of states and municipalities have challenged changes to the NSR rule change exempting grandfathered powerplants under certain conditions. The author discussed this legislation and whether the Clear Skies Act will be effective. 9 refs.
(B204)Probabilistic risk assessment (PRA) insights are now used by the United States Nuclear Regulatory Commission (USNRC) to confirm the level of safety for plant operations and to justify changes in nuclear powerplant operating requirements, both on an exception basis and as changeds to a plant's licensing basis. This report examines qualitative and quantitative risk assessments during shutdown plant states, providing feedback to utilities in the use of qualitative models for outage risk management, and also providing input to the development of the American Nuclear Society (ANS) Low Power and Shutdown PRA Standard.
(B204)Probabilistic risk assessment (PRA) insights are now used by the United States Nuclear Regulatory Commission (USNRC) to confirm the level of safety for plant operations and to justify changes in nuclear powerplant operating requirements, both on an exception basis and as changeds to a plant's licensing basis. This report examines qualitative and quantitative risk assessments during shutdown plant states, providing feedback to utilities in the use of qualitative models for outage risk management, and also providing input to the development of the American Nuclear Society (ANS) Low Power and Shutdown PRA Standard.
FuelCell Energy in Connecticut has sold 4.5 MW worth of powerplants to California renewable energy company BioFuels Fuel Cells, part of New Energy Capital and BioFuels Energy. Three molten carbonate fuel cell powerplants - a 2.8 MW DFC3000 unit, a 1.4 MW DFC1500 system, and a 300 kW DFC300 unit - will be installed at three locations in the San Diego area, and utilize purified biogas from the Point Loma wastewater treatment plant as their primary fuel source.
This report considers the effect of pipe-whip restraints and snubbers on the normal operation of piping systems in nuclear powerplants. Also considered are the effect of these postulated event devices on reliability, economics, and the exposure of plant personnel to radiation. Field data were gathered from three nuclear powerplants that had applied for Operating Licenses. Criteria, design philosophies, and data were obtained from the respective nuclear steam system suppliers, architects-engineers and utilities.
The booklet presents general information and practical hints for the task of acquiring and evaluating the data describing investments and other expenditure and activities for pollution abatement measures taken by electric utilities. The information is intended as an aid for establishing standard criteria for assignment and evaluation, and for comparison and classification of pollution abatement measures. As a line of orientation, a catalogue of pollution control measures is given, arranged into the following sections: Fossil-fueled powerplants; nuclear powerplants (BWR and PWR); hydroelectric powerplants; power transmission and distribution. (HSCH)
A case study of a small-scale hydroelectric plant to identify implementation problems is presented. The Montello hydroelectric plant is described including the background and history of the plant, the physical characteristics, the financial history and costs, operation, regulatory agencies, and the problems encountered in its operation. The analyses of the energy and capacity (demand) credits for the Montello hydroelectric plant when it is added to the Wisconsin Power and Light Company generating system is described. The WP and L base case and the results of the analyses are discussed. (WHK)
A reference design was used in preparing a mathematical model of a fusion powerplant with a tokamak reactor to investigate the extent to which the uncertainty still inherent in the physical reactor parameters affects the power costs. While only limited reductions of the power costs are achieved by improvements of the reference values for the reactor burn time, power density in the torus and load on the first wall, the power costs rise in keeping with the extent to which these parameters fall short of the reference values. As the results obtained in present-day experiments are still well below the reference values, a great deal of effort is still required in the fields of plasma physics and materials research to achieve an economically operating fusion powerplant. (orig.).
In-service Test (IST) of the nuclear powerplant is very important to maintain the safety of the plants. The safety features of nuclear powerplant are based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear powerplant to keep operational readiness of pumps and valves. Because of the importance of the IST, most of nuclear powerplants should designate the IST department and personnel. Because the nuclear powerplants of Korea have several types and the designs and operations are different from each other, the methods and experiences are various for the management of the IST program. However, there are no medium to communicate with each other and exchange the tips and information about IST program and ...
Safety related equipment installed in Korean Nuclear PowerPlants are required to perform a safety function during and after a seismic event. To accomplish this safety function, they must be seismically qualified in accordance with the intent and requirements of the USNRC Reg. Guide 1.100 Rev. 02 and IEEE Std. 344-1987. This paper defines and summarizes acceptable criteria and procedures, based on the Korean experience, for seismic qualification of purchased equipment to be installed in a nuclear powerplant. As such the paper is intended to be a concise reference by equipment designers, architectural engineering company and plant owners in uniform implementation of commitments to nuclear regulatory agencies such as the USNRC or Korea Institute of Nuclear Safety (KINS) relating to adequacy of seismic Category 1 equipment. Thus, the paper provides the methodologies which can be used ...
A three-dimensional (3D) thermal-hydraulic model and a numerical procedure for the simulation and analysis of a steady-state, as well as transient operation of nuclear powerplant components are presented. A two-fluid approach is applied to modelling of two-phase flow. Thermal-hydraulics of a horizontal steam generator in the WWER 1000 nuclear powerplant has been simulated at the full load, steady-state operation. A comparison of the numerical results with data measured at the NPP Novovoronjezh shows good agreement. 3D numerical results can be used in plant design or retrofitting, in nuclear powerplant operation and safety analysis and as improvement of existing one-dimensional thermal-hydraulics models of the horizontal steam generator which are assessed by system codes used for the nuclear power ...
A three-dimensional (3D) thermal-hydraulic model and a numerical procedure for the simulation and analysis of a steady-state, as well as transient operation of nuclear powerplant components are presented. A two-fluid approach is applied to modelling of two-phase flow. Thermal-hydraulics of a horizontal steam generator in the WWER 1000 nuclear powerplant has been simulated at the full load, steady-state operation. A comparison of the numerical results with data measured at the NPP Novovoronjezh shows good agreement. 3D numerical results can be used in plant design or retrofitting, in nuclear powerplant operation and safety analysis and as improvement of existing one-dimensional thermal-hydraulics models of the horizontal steam generator which are assessed by system codes used for the nuclear power ...
The current situation in the development of nuclear power in the world and in Czechoslovakia is briefly outlined and the possibilities are discussed of alternative energy resources. The environmental impact is described of conventional powerplants firing coal; sulphur and nitrogen oxides are mentioned and their environmental impacts shown. Their quantities and the quantities of other gaseous, liquid and soid wastes produced by coal powerplants are given. Annual estimates are presented of radioactive material emissions; trace amount emissions of toxic metals and their ecological risks are shown. Concern over the increasing concentration of CO_2 in the atmosphere is voiced. For nuclear powerplants, the amount of radionuclides in stack emission and of those released into water flows is tabulated. Their effect on the aqueous ecosystem is ...
The Wolsung-1 CANDU 600 MWe plant is now in operation. This paper provides an update on the design, construction and commissioning progress reported at last year's conference. The accomplishments of the past year are highlighted with emphasis on how the station has been commissioned in preparation for commercial service and on the skills that were dedicated to the completion of the project. The paper also deals with some of the features of the CANDU 600 MWe Nuclear PowerPlant that make it viable for export.
... As a consequence the Brazilian government introduced a thermoelectric priority programme covering the construction of new gas fired combined cycle powerplants. One such plant has been constructed at the Suape industrial port complex in the state of Pernambuco. The US$350 million Termopernambuco combined cycle gas ...
The present invention provides an improvement in the art of combined steam turbine and gas turbine powerplants of the type wherein the principal source of energy is a fluidized bed combustor fueled by coal. More specifically, the invention pertains to supplemental firing of the gas turbine cycle with a clean hydrocarbon fuel (CHF) at a high incremental efficiency to significantly increase overall plant efficiency.
This case study is an application, to a nuclear powerplant, of the methodology for quantifying environmental costs and benefits, contained in the regional energy plan, adopted in April, 1983, by the Northwest Power Planning Council, pursuant to Public Law 96-501.The study is based on plant number 2 of the Washington Public Power Supply System (WNP-2), currently nearing completion on the Hanford Nuclear Reservation in eastern Washington State. This report describes and documents efforts to quantify and estimate monetary values for the following seven areas of environmental effects: radiation/health effects, socioeconomic/infrastructure effects, consumptive use of water, psychological/health effects (fear/stress), waste management, nuclear powerplant accidents, and decommissioning costs. 103 references.
The report describes the following: overview of the Russian power industry; electric power equipment of Russia; power industry development forecast for Russia; clean coal technology demonstration program of the US Department of Energy; reduction of coal TPS (thermal power station) environmental impacts in Russia; and base options of advanced coal thermal powerplants. Terms of the application of clean coal technology at Russian TPS are discussed in the Conclusions.
The document reports the status of the 'electricity' in Lebanon since 1885 with an emphasis on its present economical situation. Data concerning electric power consumption and distribution as well as the average of rainwater, spring and weather are given. Powerplants in Lebanon, the production of electric power and its consumption are described. A quantitative analysis of specifications of powerplants and their annual and monthly production of electric power, the distribution of electricity consumption in Lebanon (geographical, annual, monthly) are presented in tables and graphs. An overview of the economical status of the 'electricity' in Lebanon is presented. The evolution of prices charges, hour cuts, damages and the impact of Lebanese wars on the distribution and the consumption of electricity are presented
System instability as result of high power generation of one of the largest plants of the Iranian electric power grid prevented the plant to be fully utilized. PSSs were installed on the generating units of the power station, to improve its small signal stability, and enhance the stable generation limit. Domain separation and pole assignment techniques were applied for the PSS design. Several field tests were also carried out to verify its effectiveness. This paper presents the PSS tuning procedure, including the design criteria and some of the field test results.
The developed electrical networks in the agricultural regions of the Estonian SSR make it possible to construct relatively powerful wind powerplants at the sites of the most favorable wind conditions with small outlays for the power transmission lines. The wind powerplant electricity can be used to electrify the production processes in agriculture, while the surplus can be supplied to the energy system. The inclusion of the wind powerplants in the energy system makes it possible to improve the total generation of energy or reduce the consumption of fuel. With the efficient arrangement of the wind powerplants, one can also reduce the energy losses during its transfer. Calculations indicated that in the coastal zones of the Estonian SSR, one can obtain specific ...
Binary geothermal plants were investigated for providing electrical power for MX missile bases. A number of pure hydrocarbons and hydrocarbon mixtures were evaluated as working fluids for geothermal resource temperatures of 365, 400, and 450/sup 0/F. Cycle thermodynamic analyses were conducted for pure geothermal plants and for two types of coal-geothermal hybrid plants. Cycle performance results were presented as net geofluid effectiveness (net plant output in watts per geofluid flow in 1 bm/hr) and cooling water makeup effectiveness (net plant output in watts per makeup water flow in 1 bm/hr). A working fluid containing 90% (mass) isobutane/10% hexane was selected, and plant statepoints and energy balances were determined for 20MW(e) geothermal plants at each of the three resource temperatures. Working fluid heaters ...
This paper describes a maintenance problem in a fusion powerplant. The problem is to specify which life limited parts should be replaced when there is an opportunity. The objective is to minimize the cost rate of replacement parts and of maintenance actions while satisfying a powerplant availability constraint. The maintenance policy is to look ahead and replace all parts that will reach their life limits within a time called a screen. Longer screens yield greater system availabilities because more parts are replaced prior to their life limits.
This document draws together data on hydroelectric power generation and dam construction for 1996. Machinery such as turbines and hydroelectric generators are listed together with their manufacturers. Contact addresses for international organizations concerned with water power are listed. Listings are also given for hydro resources worldwide, and the global distribution of pumped-storage plants, dams and hydroelectric plants. Company data is also listed providing a buyer`s guide for 1996. (UK)
This standard provides requirements and guidelines for installation, inspection and testing activities that assure the quality of important mechanical parts of a nuclear powerplant not covered by the ASME Boiler and Pressure Vessel Code, Section III, during construction. These parts include those mechanical systems and components whose satisfactory performance is required: for the plant to operate reliably; to prevent accidents that could cause undue risk to the health and safety of the public; or to mitigate the consequences of such accidents if they were to occur. The requirements of this standard deal with the protection and control necessary to assure that the requisite quality of those important parts of the plant are preserved from the time items are removed from storage or receiving until they are incorporated into the plant up to but not including fuel loading for PWR ...
The purpose of the chapter is to explain briefly the various considerations that enter into determining the general layout or arrangement of typical hydroelectric powerplants, pumping plants, and pumped-storage plants. Some of the important factors that affect or determine the location, type, and layout of the plant and the selection of the major items of equipment included in the installation are outlined in this chapter. The first consideration in the design of a powerplant, pumping plant, or pumped-storage plant is that it adequately perform its function and be structurally safe. The structure is also designed to give a pleasing architectural appearance.
Experience and technical innovations in powerplant engineering have resulted in continuous improvements of operation control, availability and safety of pumped storage plants. Process control is constantly improved as new developments are made in equipment and systems engineering. Plant control concepts with increasingly complex automation hierarchy are described by which pumped storage processes can be controlled optimally, reliably, and automatically.
A survey has been made in relation with the improvement project intended of energy conservation, and reduction of global warming gas emission at the Bobovdol thermal powerplant located in the suburb of Sofia, the capital of the Republic of Bulgaria. The existing Bobovdol powerplant having a total capacity of 630 MW with three generators is a coal burning thermal powerplant having been used already for 23 to 27 years, hence over-aged. The survey has discussed an improvement project of scrap-and-build type to make the plant a high-efficiency gas combined cycle powerplant using gas turbines. The project calls for building 210-MW gas combined power generation facilities having 70-MW gas turbines, one each in three stages in 2007, 2012 and 2017. As a result of the discussions, the ...
Due to the failure of the instrument and control devices of nuclear powerplants caused by aging, nuclear powerplants occasionally trip. Even a trip of a single nuclear powerplant (NPP) causes an extravagant economical loss and deteriorates public acceptance of nuclear powerplants. Therefore, the replacement of the instrument and control devices with proper consideration of the aging effect is necessary in order to prevent the inadvertent trip. In this paper we investigated the optimal replacement periods of the control computer's components of Wolsung nuclear powerplant Unit 1. We first derived mathematical models of optimal replacement periods to the digital control computer's components of Wolsung NPP Unit 1 and calculated the optimal replacement periods analytically. We ...
The Wolsung-1 CANDU 600 MWe plant is now in operation. This paper provides an update on the design, construction and commissioning progress reported at last year's conference. The accomplishments of the past year are highlighted with emphasis on how the s...
Scaling relations among plant traits are both cause and consequence of processes at organ-to-ecosystem scales. The relationship between leaf nitrogen and phosphorus is of particular interest, as both...Full Text Available
This paper describes the advent of energy pumped storage plants in France, in connection with nuclear power reactors development and gives detailed specifications of different components (pump turbines, alternators, valves ...). 5 figs., 3 tabs.
The report gives results of an analysis of the effect of the availability of a flue gas desulfurization system on the ability of an individual powerplant to generate electricity at its rated capacity. (The availability of anything is the fraction of time it is capable of service, whether or not it is actually in service.) Also analyzed are its effects on a power generating system (a group of several coal-, oil-, and gas- fired powerplants plus nuclear and hydroelectric plants).
Seven central-receiver, solar-thermal powerplants with heliostat concentrators have been built around the world in the last two decades. This technology has proven to be much too expensive for commercial powerplants and efforts to reduce the cost have reached an impasse. It is the nature of the solar concentrators which makes it so expensive. There are two types of concentrators: those, called heliostats, with mirrors on stationary supports, and those with mirrors on mobile supports. Mobile mirrors are potentially much cheaper than heliostats.
Increasing demand for energy production with low impact on the environment and minimised fuel consumption can be met with high efficient coal fired powerplants with advanced steam parameters. An important key to this improvement is the development of high temperature materials with optimised mechanical strength. Based on the results of more than ten years of development a coal fired powerplant with an efficiency above 50 % can now be realised. Future developments focus on materials which enable an efficiency of 52-55 %. (orig.) 25 refs.
The importance of radiation management for nuclear facilities including nuclear powerplants has increased as the general public understanding has progressed, and necessary information for management must be processed exactly and quickly. In nuclear powerplants, radiation management is performed by each individual operation, and collected information is managed by the system of each operation. The distributed-processing radiation management system has been developed aiming to use a general-purpose LAN and make quick and efficient use of information managed by individual operations. This paper describes the system configuration and functions. (author)
As part of the ICAP (International Code Assessment and Applications Program) agreement between ECN (Netherlands Energy Research Foundation) and USNRC, ECN has performed a number of assessment calculations for the thermohydraulic system analysis code RELAP5/MOD2/36.05. This document describes the assessment of this computer program versus a natural circulation experiment as conducted at the Borssele Nuclear PowerPlant. The results of this comparison show that the code RELAP5/MOD2 predicts well the natural circulation behaviour of Nuclear PowerPlant Borssele.
The first 750 MW block of the new South Humber Bank gas-fired combined cycle powerplant, sited about 300 km north from London, was officially commissioned in September 12th 1997. The project has been a major success story for Imatran Voima Oy (IVO), which developed the concept and managed the project and owns 22.5 % of the plant; and ABB PowerPlants Limited, responsible for the turnkey delivery. IVO Generation Services (UK) is responsible for the running and maintenance of the facility. IVO also manages two other existing plants in Britain, at Brigg (240 MW) and Peterborough (360 MW)
The first 750 MW block of the new South Humber Bank gas-fired combined cycle powerplant, sited about 300 km north from London, was officially commissioned in September 12th 1997. The project has been a major success story for Imatran Voima Oy (IVO), which developed the concept and managed the project and owns 22.5 % of the plant; and ABB PowerPlants Limited, responsible for the turnkey delivery. IVO Generation Services (UK) is responsible for the running and maintenance of the facility. IVO also manages two other existing plants in Britain, at Brigg (240 MW) and Peterborough (360 MW).
The operation of pumped-storage plants (PSP) is based on the daily load variations of power demand. It performs power generation at peak load times during the day, and pumps water up into the reservoir during the off-peak times at night. In the Taipower system in Taiwan, there are two pumped storage plants with ten units. These had a total installed capacity of 2,602 MW or a 12 percent capacity at the end of 1995. The plants were able to reduce system generation costs and improve reliability. A Pumped-Storage Plant Benefit Analysis (PSPBA) program was established using the principle of economic dispatch in 1985. This paper explains the rules of the program, the analysis results of the past 10 years, and a a cost benefit evaluation. It was found that the advantages of PSP are not only in supplying the power for peak load, but also in ...
Concepts involving combined gas-turbine/steam-turbine power-generation plants, in which the fuel gas for the gas turbine is produced via the gasification of coal, are now extremely advanced. This technology already permits efficiencies of around 50% current development targets view 65% as achievable. In conventional technology, efficiencies are tied to conditions, such as air and cooling-water temperatures, at the particular location. In combined-cycle powerplants, the properties of the fuel coal also play an important part. There are, in face, coals which can be more advantageously used in a combined-cycle powerplant than in a conventional one. These differences, combined with advantageous concepts for coal-fired combined-cycle power-generating plants, are presented and analyzed. Particular attention is devoted to ...
The U.S. Trade and Development Program (TDP) had received a request from the Hungarian Electricity Board (MVMT) for assistance in support of a feasibility study program to: (1) install new generation capability based on gas/oil fired combined cycle powerplants, and (2) retrofit/refurbish a number of aging coal and oil fired steam plants. A Definitional Mission (DM) recommends that TDP fund the requested feasibility studies for new gas/oil fired combined cycle capabilities discussed in the Terms of Reference (TOR). Hungary will need to install significant new power capacity between now and the end of the century. Gas/oil fired combined cycle plants present probably the only option to install capacity rapidly. There is an opportunity for U.S. firms to supply technology and services with respect to these advanced power generation technologies.
This is a presentation on Human Factors in reactor operations. It discusses issues that deal with powerplant operations, training and design, operational effectiveness and safety, supporting people to achieve effective and error free performance.
A review of the literature is provided for the topic of health-related research and power frequency electromagnetic fields. Minimal evidence for concern is present on the basis of animal and plant research....Full Text Available
Rapid administration of stable iodine is essential for the saturation and subsequent protection of the thyroid gland against the potential harm caused by radioiodines. This paper proposes the Dutch risk analysis that uses an atmospheric dispersion model to calculate the size of the zones around nuclear powerplants where radiological thyroid doses for children might be sufficiently high to warrant iodine administration. Dose calculations for possible releases from the nuclear powerplants of Borssele (The Netherlands), Doel (Belgium) and Emsland (Germany) are based on two scenarios in combination with a 1-y set of authentic, high-resolution meteorological data. The dimensions of the circular zones were defined for each nuclear powerplant. In these zones, with a radius up to 50 km, distribution of stable iodine tablets is advised. PMID:20332130
Rapid administration of stable iodine is essential for the saturation and subsequent protection of the thyroid gland against the potential harm caused by radioiodines. This paper proposes the Dutch risk analysis that uses an atmospheric dispersion model to calculate the size of the zones around nuclear powerplants where radiological thyroid doses for children might be sufficiently high to warrant iodine administration. Dose calculations for possible releases from the nuclear powerplants of Borssele (The Netherlands), Doel (Belgium) and Emsland (Germany) are based on two scenarios in combination with a 1-y set of authentic, high-resolution meteorological data. The dimensions of the circular zones were defined for each nuclear powerplant. In these zones, with a radius up to 50 km, distrib...
Presented here is the calculation of radionuclide concentration in gaseous effluents from the Daya Bay Nuclear PowerPlant by using the Gaussian model, based on the analysis of the radionuclides in gaseous effluents and based on the measured wind field in the area of Guangdong province in November 2005. The calculating results about the relative concentration distribution of the radionuclides in Guangdong province, especially in Daya Bay, Shengzheng, Zhuhai and Guangzhou, are obtained. These results can provide reference data for the effect of radiation on the environment of Guangdong province under normal conditions of operation of the Daya Bay Nuclear PowerPlant. It can also provide reference data for monitoring possible nuclear incidents in nuclear powerplants. (authors)
Presented here is the calculation of the diffusion of radionuclides from the Daya Bay Nuclear PowerPlant under normal operation on the basis of Gaussian model. The model is modified partially considering practical situation, and monitoring meteorological data are adopted. By using the AIRDOS-EPA computer code, the average annual ground-level concentration distribution of radionuclides from Daya Bay Nuclear PowerPlant in 2001 was obtained, the atmospheric dispersion factor and ground deposition rate were also acquired. These calculated results can provide information for understanding the effect on radiation environment due to Daya Bay Nuclear PowerPlant under normal operation. (authors)
Less wind powerplants in the landscape, more power from renewables, less carbon dioxide and higher tax: The advantages of repowering for communities are considerable. Still, they are hesitant to use it. (orig.)
This document is a discussion of a static electrification event in each of the 1050 MVA units installed at the Koeburg Nuclear PowerPlant in South Africa. Results of a tear-down inspection performed after the event are given, as is an analysis of the event. A number of photographs are included.
Electric utility plants, for which construction commenced after September 18, 1978, must install and operate continuous emission monitoring (CEM) systems to demonstrate compliance with SO_2 and NO_x emission standards. Furthermore, effective December 4, 1987, each plant must develop and implement a CEM quality assurance (QA) program. This paper reviews the CEM and QA requirements set forth by new source performance standards (NSPS) promulgated by the Environmental Protection Agency. The paper summarizes operating characteristics of the 32 powerplants currently subject to NSPS and describes the types of CEM systems used by these plants. Also, to the extent available, the paper presents the results of initial (i.e., first quarter 1988) QA activities (e.g., audits and calibration drift assessments) conducted by these plants.
Although not Pakistan`s first independent power project, the 586 MW Uch plant is certainly one of the country`s most important. It is the first gas-fired combined cycle plant to be developed under Pakistan`s Private Power Policy, and uses low heating value natural gas previously thought worthless. The project also features some innovative financing arrangements, and with construction now at an advanced stage, it promises to kick-start the development of private power in Pakistan. (Author)
The layout of the network with its frequency and transmission power control shows how the time behaviour of powerplants and consumers determines the frequency curve during sudden power disturbances. As for switching processes in the network for the turbine, network operation entails loads due to shock-like disturbance functions to which one should not normally respond by switching off. The interception controllers are therefore adjusted via a simulation model by which the vibrations of the turbine rotor can be modelled in real time under different network loads. (GL).
National Power is building its first gas turbine combined cycle power station at Killingholme, situated to the south of the River Humber in the East of England. NEI ABB Gas Turbines Limited was awarded the turnkey contract in July 1990 to build a nominal 650 MW combined cycle power station based around three Asea Brown Boveri GT13E gas turbines. The project is outlined in this article. The plant is due for completion in July 1993. (author)
The author describes feasibility study on the scheme of disposing spent guide tubes at Daya Bay nuclear powerplant, including scheme selection, packing cask design, disposal operation and technological process, budget estimation and safety evaluation. The research results show that the new scheme is feasible on technology, and reasonable on budget. If the scheme is adopted to dispose the spent guide tubes at Daya Bay nuclear power station, it can not only save large funds, but also accumulate experience on disposing non-compressible low and intermediate level solid radioactive wastes produced at nuclear power station for the country
The digital AVR must have the level of redundancy and control functions that conform to the configuration of the excitation control system and to the importance of a particular generator for the user. The digital AVR is not simply a digital version of the analog AVR, but can realize sophisticated control functions that were difficult to achieve with analog circuits, thus making it possible to enhance the stability of power system by PSS (power system stabilizer). This paper describes the test results of the digital AVRs applied to powerplants, their system configuration and functions, as well as the outline of an auto-tuning PSS or AT-PSS planned to be incorporated in the digital AVR in the future.
The development status of the EE-1 Small Community Solar Thermal Power Experiment (SCSE Program) is presented. Current activities on the Phase II single module development effort are presented, together with plans for a Phase III 1 MW/sub e/ demonstration plant. A description of the various subsystems and components is given with a brief review of their development background. Latest performance figures are given for a 1 MW/sub e/ plant, based on 56 power modules, each consisting of a 12m parabolic dish concentrator, a cavity receiver, an organic Rankine power conversion subsystem and a ground-mounted solid-state rectifier.
In this work, the right management procedure for hydraulic power oil will be discussed and suggested. A thermal powerplant turbine should respond to the change of load status. However, to satisfy the frequency of alternating current, the revolution per minute should be kept constant. Therefore, by controlling the flow rate of the steam to the turbine, the governor satisfies the load variation without alternating the revolution per minutes of the turbine. To protect the governor, the hydraulic power unit should be managed carefully by controlling the quality and the flow rate of the oil.
As for No.2 plant in Sendai Nuclear Power Station, which is the fourth nuclear power generation facilities in Kyushu Electric Power Co., Inc., all works have been completed, and at present, the final trial operation is under way. In No.2 plant, many new techniques for raising the reliability and safety, improving the maintainability and reducing radiation exposure were introduced on the basis of the operation experience of PWRs obtained so far, similarly to No.1 plant. In this paper, the main items of the new techniques related to the design and construction of the plant are reported. No. 2 plant is a first improved and standardized plant having the thermal output of 2660 MW for standard three-loop PWRs, and the rated power output was set at 890 MW. As for the turbine, TC6F-40 in ...
Pumped storage plants participate in two structurally different markets: the market for scheduled energy (also known as spot market) and the reserve market. In order to achieve the best possible plant scheduling in terms of revenues the marketing of the available capacity from pumped storage plants needs to be optimised in both markets. Moreover, due to the abilities for providing reserve, pumped storage capacities within an existing powerplant portfolio can lead to synergies for the whole portfolio. The optimised combined participation of a powerplant in both spot and reserve market as well as the coherent portfolio effect are considered as particular challenges in energy economic assessments, e.g. in the light of investment decisions. Based on an extension project and in cooperation with RWTH Aachen University an optimised combined ...
This paper reports on pumped storage plants which have become an effective way for some utility companies that derive power from hydroelectric facilities to economically store baseload energy during off-peak hours for use during peak hourly demands. According to the Electric Power Research Institute (EPRI) in Palo Alto, Calif., 36 of these plants provide approximately 20 gigawatts, or about 3 percent of U.S. generating capacity. During peak-demand periods, utilities are often stretched beyond their capacity to provide power and must therefore purchase it from neighboring utilities. Building new baseload powerplants, typically nuclear or coal-fired facilities that run 24 hours per day seven days a week, is expensive, about $1500 per kilowatt, according to Robert Schainker, program manager for energy storage at the EPRI. Schainker the that ...
This paper reports on pumped storage plants which have become an effective way for some utility companies that derive power from hydroelectric facilities to economically store baseload energy during off-peak hours for use during peak hourly demands. According to the Electric Power Research Institute (EPRI) in Palo Alto, Calif., 36 of these plants provide approximately 20 gigawatts, or about 3 percent of U.S. generating capacity. During peak-demand periods, utilities are often stretched beyond their capacity to provide power and must therefore purchase it from neighboring utilities. Building new baseload powerplants, typically nuclear or coal-fired facilities that run 24 hours per day seven days a week, is expensive, about $1500 per kilowatt, according to Robert Schainker, program manager for energy storage at the EPRI. Schainker the that ...
The power sector in Thailand is the largest contributor to CO{sub 2} emissions. There is high potential to mitigate CO{sub 2} emission via alternative power generating plants. Alternative plants considered in this study include nuclear plants, integrated gasification combined cycle plants, biomass-based plants and supercritical thermal powerplants. The biomass-based plants considered here are fueled with four types of biomass; paddy husk, municipal solid waste (MSW), fuel wood and corncob. The methodology for the optimal expansion plan of the power generating system over the planning horizon is based on the least-cost approach. The results from the least-cost planning analyses show that the nuclear alternative has the highest potential to mitigate not only ...
Daya Bay Nuclear Power Station is the largest joint-venture project which is also the largest commercial nuclear powerplant currently under construction in China mainland. Organized and executed strictly in accordance with international standards, the Daya Bay project is seen as the first step taken by China in the development programme of large-capacity commercial nuclear power units.
Electricity is a universal energy and one of the driving powers of civilisation. World-wide, future developments like growing economies and structural changes in industry, a higher standard of living and a bigger world population - are impossible without appropriate supply of power and electricity. An expert of Siemens Power Generation presents his views. (orig.)
Due to its important hydroelectric power generation facilities (about 525 plants with a total power of 13,314 MW producing about 35.3 TWh annually) Switzerland plays an important role in the interconnected European power system. Large artificial storage lakes in the Swiss Alps can generate peak power during hours of highest demand: 9700 MW are available from accumulated energy and the total power of pumped-storage facilities amounts to 1700 MW. The latter allow refilling the reservoirs at periods of low power demand and generating power at periods of peak demand. In the case of favorable conditions, the yearly average power production could be increased by 6% and the production during the winter period (October to March) by 20% by the year 2020. However, looking forward to the year 2050, the annual ...
Since 1995, OECD started to examine the current situation of government regulation in each member country and discussed to recommend quality improvement of regulation to member countries. The conference on reformation of regulation in power industry was held in October and December 1998. In USA, enhancing competition in supplying electricity was recommended by eliminating differentiation in use of power network, transmission network and incidental facilities. The retail competition is also an important reformation. The reformation in Netherlands can be seen as following EU guide for revealing problems of the existing regulation in the power industry and for opening up a power market. The Dutch government passed the power act for opening up a market to the public between 1999 and 2007. In Japan, the entry of independent power provider (IPP) has been softened. ...
This third Missouri River Basin Commission report on Status of Electric Power in the Missouri River Basin provides information on the status of electric power generation, future needs, and potentials for meeting these needs. Information for this 1980 update is based upon available published information up to and including December 31, 1979. State and federal members of the Missouri River Basin Commission provided information for sections of the report and on legislative activities. Information is included on the planning and projected costs of hydro, nuclear and fossil-fuel powerplants, pumped-storage plants, transmission systems, projected power demands, the environmental, socio-economic-cultural impacts of electric power generation, and regulations affecting energy development. (LCL)
Article. In Norway, a project is planned to evaluate the upgrading potential of the hydroelectric power sector. The article criticizes the authorities for not supporting the upgrading of hydroelectric powerplants in their eager to promote the development of wind power. An important contribution of the planned project will be a book from which the utilities may get advice on measures of upgrading. Generators and control systems account for 80% of the faults and interruptions in the power utilities. The turbine technology has made important progress in the 1990s. By pure upgrading measures alone, the turbine efficiencies may be increased enough for an additional 3 TWh to be taken out from the Norwegian hydroelectric power system. Today, the price of imported carbon-based Danish power determines whether the utilities find it profitable to ...
Experience with the identification and tuning of exciter constants for a generating unit as the Second Nuclear PowerPlant of Taiwan Power Company is reported. Field test is first performed on the excitation system with the generator open-circuited. Since the field test results differ from the computer simulation results using manufacturer`s constants, the authors first modify the manufacturer`s constants based on their previous experience to reach a preliminary set of parameters for the excitation system. Then a hybrid nonlinear simulation-sensitivity matrix method is developed to further refine the excitation system parameters. The exciter constants are tuned in order to give better dynamic response before a power system stabilizer is applied to the generator. Field tests are then performed in order to compare the dynamic response of the generator without and with power system ...
Experience with the identification and tuning of exciter constants for a generating unit as the Second Nuclear PowerPlant of Taiwan Power Company is reported. Field test is first performed on the excitation system with the generator open-circuited. Since the field test results differ from the computer simulation results using manufacturer's constants, the authors first modify the manufacturer's constants based on their previous experience to reach a preliminary set of parameters for the excitation system. Then a hybrid nonlinear simulation-sensitivity matrix method is developed to further refine the excitation system parameters. The exciter constants are tuned in order to give better dynamic response before a power system stabilizer is applied to the generator. Field tests are then performed in order to compare the dynamic response of the generator without and with power system ...
Weakly penetrating radiation monitoring and investigating with area monitors and individual dosimeters were carried out at Daya Bay nuclear powerplant during its refueling outages. This paper introduces monitoring methods, measuring results, data analysis and assessment, presents some suggestions for monitoring plan and protection measures in the future as well. (authors)
The water and steam circuits of steam generators in pressurized-water nuclear powerplants are described together with the mechanism of denting, and the corrosion of spacer plates that leads to cracks in tubes by constriction. The different chemical specifications applicable to the water of the secondary circuit of the generators in normal operation and on first commissioning are listed. The results obtained and the measurements of chemical values taken in operation on the water in the secondary circuits of steam generators at Fessenheim and Bugey are presented.
The water and steam circuits of steam generators in pressurized-water nuclear powerplants are described together with the mechanism of denting, and the corrosion of spacer plates that leads to cracks in tubes by constriction. The different chemical specifications applicable to the water of the secondary circuit of the generators in normal operation and on first commissioning are listed. The results obtained and the measurements of chemical values taken in operation on the water in the secondary circuits of steam generators at Fessenheim and Bugey are presented.
The failure of receivers has been one of the main operating problems at the White Cliffs solar thermal powerplant. This Technical Note reports the results of an initial investigation that identifies the cause as having been their thermal fatiguing of the tube walls. The fatigue appears to be caused by unstable heat transfer at vapor qualities below the point where critical heat flux is generally exceeded. Methods for avoiding this problem are tested.
The possibility of using Direct Flow Control (DFC) to avoid catastrophic accidents due to containment breaches in chemical plant is discussed. Recommendations are made for locating fluidic elements, and the effectiveness of simple DFC protection is analysed. More powerful methods of protection are outlined using spin diversion and the complementary properties of fluidic and conventional valves are exploited. (author).
MOX fuel has been one of the mature nuclear fuels which can be used in light water nuclear powerplant now. The development status in this domain in foreign countries, the major influence of MOX fuel on reactor performance and the countermeasures are introduced in this paper. The application of MOX fuel in China's PWR is discussed in the end. (authors)
The rod drop time event of the Daya Bay Nuclear PowerPlant is caused by the malfunction of the guide tube developed by Framatome. Three temporary solutions were implemented successively and the long term solution was found in the process of searching for the root cause. The different solutions and the root cause are introduced. The safety analysis and license of the solutions are mainly discussed. Experiences and lessons are drawn by summarizing the important items related to nuclear safety.
'Small radioactive source results in big accident' have occurred repeatedly in China and worldwide alike. Radioactive source management is one of the key activities for a nuclear powerplant to maintain its good safety record and image to the public. From aspects of establishing the management system, centralized storage, periodic accounting, performing whole process control to the source usage and experience feedback etc., the author reports the practice and experience of radioactive source management in Daya Bay Nuclear PowerPlant
This standard describes requirements and provides guidelines for the control of activities to be exercised during procurement of items and services which affect the quality of nuclear powerplants. These requirements and guidelines apply to procurement activities for items and services such as designing, purchasing, fabricating, handling, shipping, storage, cleaning, constructing, erecting, installing, inspecting, testing, maintaining, repairing, initial fueling, refueling, and modifying.
Apppendix B of 10 CFR Part 50 establishes quality assurance requirements for the operation of nuclear powerplant safety-related structures, systems and components. This Guide describes an acceptable method for complying with these regulations with regard to overall quality assurance program requirements for the operation phase of nuclear powerplants. Input to this Guide has been provided by the Advisory Committee on Reactor Safeguards.
This volume on specifications for the Saguaro PowerPlant includes the following: subsystem interface definition document; solar collector subsystem specification; receiver specification; thermal energy storage specification; solar steam generator specification; and master control system specification.
The paper discusses the role of the Life Management Programme in ensuring a safe operation of the Dukovany nuclear powerplant. The Programme involves the following major items: (i) primary circuit materials degradation assessment, (ii) pipeline damage control by the Flow Assisted Corrosion Monitoring and Prediction Programme, and (iii) the DIALIFE diagnostic system. (author)
The evaluation of the hazard posed to the skin by very small radioactive sources (diameter < 1mm) has become popularly known as the 'hot particle' problem in European and American nuclear reactor facilities. In this study, research to detect hot particle was performed in Wolsung Nuclear powerplant (NPP) in Korea.
The evaluation of the hazard posed to the skin by very small radioactive sources (diameter < 1mm) has become popularly known as the 'hot particle' problem in European and American nuclear reactor facilities. In this study, research to detect hot particle was performed in Wolsung Nuclear powerplant (NPP) in Korea.
The special geodetic problems encountered during the construction of the Paks nuclear powerplants are treated. The main building with its hermetically connected components including the reactor, the steam generators, the circulation pumps etc. impose special requirements on the control net of datum points. The geodesy tasks solved during the construction of the main building are presented in details.
Often measures of protection and restoration of reinforced concrete structures are not taken until damage occurs which affects powerplant operation. These failures can be avoided by predictive civil engineering maintenance and repair. The consequent application and implementation of a life-time management system for powerplant buildings is being suggested. (orig.)
This standard addresses the design bases for light water reactor, nuclear powerplant structures and components essential for the protection of public health and safety from the potential adverse effects of pipe whip, jet impingement, pressurization of compartments outside containment, environmental conditions and flooding associated with a postulated pipe rupture. The design bases for missile protection and the design bases for containment pressurization are not within this standard.
A historical overview of corrosion problems found in powerplant condensers and mitigation procedures is presented. The paper is organized according to alloy type and failure mode. Alloys considered are copper-base alloys, stainless steels and titanium. Failure modes discussed include erosion-corrosion, sulfide attack, environmentally assisted cracking, galvanic corrosion, steam condensate corrosion, pitting corrosion, and dealloying. Mitigation procedures discussed include cathodic protection, ferrous ion injection, as well as tube cleaning and layup practices.
The early accident Sequence of the Station Blackout accident is simulated for Daya Bay Nuclear PowerPlant, using MELCOR code. The radioactivity of main fission products was derived after calculating the source term in containment. The data will be used for Daya Bay NPP PSA analysis
This standard addresses the design bases for light water reactor, nuclear powerplant structures and components essential for the protection of public health and safety from the potential adverse effects of pipe whip, jet impingement, pressurization of compartments outside containment, environmental conditions and flooding associated with a postulated pipe rupture. The design bases for missile protection and the design bases for containment pressurization are not within this standard.
In co-operation with the Scientific Planning Department of the Central Research Institute for Vessel- and Turbine Building the construction office of the turbine factory Charkow finished the draft of a slowly running (n = 1500 min"-"1) 2 GW-turboset for the operation of nuclear powerplants. The chief purpose of the project was to determine the technical problems that are used to occur during the development of such steam turbines, as well as to settle the most favourable design. (orig./GL).
The focus of the March-April issue is on plant maintenance and plant life extension. Major articles/reports in this issue include: Spent fuel: myths and facts, by Jeffrey S. Merrifield, U.S. Nuclear Regulatory Commission; Critical pipe replacement procedure, by Geoff Gilmore, Climax Portable Machine Tools Inc.; Improving maintenance performance, by Larry Meyer and Joe Giuffre, DC Cook Nuclear Plant, American Electric Power; Equipment deficiency intolerance index, by Douglas F. Helms, Tennessee Valley Authority; Plant profile: I and C modernization at Dukovany, by Josef Rosol, CEZ Dukovany NPP, Czech Republic; and, Report: new plant activities.
The As Pontes coal-fired powerplant in northwest Spain is the largest single emitter of sulphur dioxide in the 'old' EU15. The plant is also among the largest emitters of nitrogen oxides and carbon dioxide in the region, according to the EPER (European Pollutant Emission Register). But Spain has also several other large emitters of air pollutants. The Andorra which is located in the province of Teruel is one of them. The Andorra powerplant emitted 209,148 tones of SO{sub 2} in 2002 which makes it the second largest single emitter of SO{sub 2} in the EU15. It also emitts large quantities of NOx. Also in the northwest of Spain, the Composilla and La Robla powerplants are the SO{sub 2} and NOx emitters.
Fully-fired combined cycle plants utilizing the high temperature gas turbine discharge as gas intake for a coal-fired steam generator were developed in the 1960's. Long-term experience and the excellent reliability statistics of the gas turbines of these plants have proven that the thermodynamic, economical and ecological advantages of combined cycle units over conventional units strongly suggest such plants for fossil-fuel applications. This paper describes the design and operation of these plants. Topics are Gersteinwerk Unit K combined-cycle powerplant, plant design concept, design criteria and performance, gas turbines, steam generators, steam turbines, various modes of operation, typical plant start-up, environmental considerations, prototype plants and topping old steam turbine ...
The Catalagzi Thermal PowerPlant (CTPP) is located at nearly 13 km North-east of Zonguldak city, which is located at the West Black Sea coast in Turkey. The middling products with high ash content of bituminous coals are used in this plant. Seasonal radon concentration measurements have been carried out by using CR-39 plastic track detectors in and around the CTPP. The annual average radon concentration has been found to vary from a minimum of 39.8 {+-} 28.9 Bq m{sup -3}) in the ash area to a maximum of about to 75.0 {+-} 15.7 Bq m{sup -3} in the service building of the powerplant. The annual average radon concentration in the dwellings of the thermal powerplant colony of the plant is 71.0 {+-} 33.4 Bq m{sup -3}. The effective dose has been found to vary from 0.38 to 0.71 mSv y{sup -1} with a mean value of 0.56 mSv ...
The association of Finnish Plastics Industry examined the possibilities to utilize energy content of plastic wastes in spring 1990. A bark fuelled boiler plant of forest industry was used as test powerplant. The power of the plant was 60 Mw. This report discusses shortly the theory of combustion of plastics. About 130 000-15 000 tons of plastic waste, corresponding to 7 % of the solid municipal waste, is dumped annually in Finland. Utilization of the plastic waste recovered from municipal wastes for energy production is technically viable in present powerplants among present energy production. The chipping and mixing of the plastic in the other fuel are the only pretreatment required for the plastic waste. In Finland there are several powerplants using suitable fuels for plastic mixture ...
A wider use of renewable energy sources is considered to be the solution to fossil fuel depletion and environmental pollution. This paper discusses various design considerations for line focussing technology to achieve high efficiency and the possibility of generating power in the megawatt range based on solar thermal technologies. The impacts on the environment of conventional thermal powerplants is outlined and an estimate made of the cost of pollution abatement measures. A cost benefit analysis is made using a typical 200 megawatt solar thermal plant, 500 km from the load centre, compared with a 220 megawatt coal fired and a similar capacity gas fired powerplant, as examples. The results indicated that the energy from the solar thermal powerplant is almost twice as expensive compared to conventionally generated ...
A wider use of renewable energy sources is considered to be the solution to fossil fuel depletion and environmental pollution. This paper discusses various design considerations for line focussing technology to achieve high efficiency and the possibility of generating power in the megawatt range based on solar thermal technologies. The impacts on the environment of conventional thermal powerplants is outlined and an estimate made of the cost of pollution abatement measures. A cost benefit analysis is made using a typical 200 megawatt solar thermal plant, 500 km from the load centre, compared with a 220 megawatt coal fired and a similar capacity gas fired powerplant, as examples. The results indicated that the energy from the solar thermal powerplant is almost twice as expensive compared to conventionally generated ...
The externally fired combined cycle is emerging as an economically viable repowering options for old non-competitive coal fired steam plants. This paper describes the initial operation of a pilot plant located at Kennebunk, Maine and the initial work on the repowering of a 48MW coal fired steam plant located in Warren, PA.
The report gives results of a pilot-plant study of the ammonia absorption/ammonium bisulfate regeneration process for removing SO2 from the stack gas of coal-fired powerplants. Data were developed on the effects of such operating variable in the absorption of SO2 by ammoniacal l...
Installation of the electrical equipment at the Barstow Solar Pilot Plant is the concern of this construction package. Technical specifications for power and instrument cables, meteorological instruments, and control cables are defined. The documentation requirements are briefly discussed.
Power Fluidic systems for the control of liquids and gaseous flows have been adopted for use in radioactive processing plants in the UK. These devices are intrinsically reliable with no mechanical moving parts because they are able to make use of the hydrodynamics of the fluids being controlled. This reliability feature leads to a zero cell maintenance concept and the elimination of mechanical drive/control systems in cell. The first phase of the development work led to their use in the Fast Reactor Reprocessing Plant at Dounreay and the Highly Active Liquor Storage facility at Sellafield. The success of these early developments has led to an extensive development programme for an extended range of applications in the Thermal Oxide Reprocessing Plant and its associated waste treatment facilities at Sellafield. The technology has now been fully demonstrated and adopted for these ...
The IAEA Assessment of Safety Significant Events Team (ASSET) report presents the results of an ASSET team's assessment of their investigation of the effectiveness of the plant for prevention of incidents since 1990 at Zaporozhe nuclear powerplant. The results, conclusions and suggestions presented herein reflect the views of the ASSET experts. They are provided for consideration by the responsible authorities in Ukraine. The ASSET team's views presented in this report are based on visits to the plant, on review of documentation made available by the operating organization and on discussions with utility personnel. The report is intended to enhance operational safety at Zaporozhe by proposing improvements to the policy for the prevention of incidents at the plant. The report includes, as a usual practice, the official response of the operating organization as well as of the ...
The fundamental points to be considered in a waste treatment system for a country like Japan, where the final disposal method has not been decided and the wastes have to be stored in the powerplants, are volume reduction of the wastes, safe storage of the wastes in the plant, and flexibility regarding the final disposal. A system has been developed that consists of a thin film evaporator for the direct solidification of the liquid waste, a pelletizer for producing hard pellets from the powdered wastes, a pellet storage unit, and a solidification unit for the final disposal. A pilot plant with waste treatment capacity of 200 kg/h was built in 1976 and has proved the system feasibility. This paper reports on pilot plant tests of the thin film evaporator and other components, tests on pellet deterioration during long term storage, and integrity tests on the final disposal of the ...
The fundamental points to be considered in a waste treatment system for a country like Japan, where the final disposal method has not been decided and the wastes have to be stored in the powerplants, are volume reduction of the wastes, safe storage of the wastes in the plant, and flexibility regarding the final disposal. A system has been developed that consists of a thin film evaporator for the direct solidification of the liquid waste, a pelletizer for producing hard pellets from the powdered wastes, a pellet storage unit, and a solidification unit for the final disposal. A pilot plant with waste treatment capacity of 200 kg/h was built in 1976 and has proved the system feasibility. This paper reports on pilot plant tests of the thin film evaporator and other components, tests on pellet deterioration during long term storage, and integrity tests on the final disposal of the ...
Being based on the Segal method, calculation was carried out for the natural uranium nuclear fuel cost with Zircaloy-4 cladding having design parameters of Wolsung Nuclear PowerPlant, CANDU-PHWR (Unit 1), currently under construction in Korea aiming at its completion in 1982. An attempt was also made for the sensitivity analysis of each fuel component; i.e., depreciation of fuel manufacturing plant caused by its life time, its load factor, production scale expansion of plant facilities, variations of construction and operating costs of fuel manufacturing plant, fluctuation of interest rates, extent of uranium ore price increases and effect of learning factor. (author).
Design and procurement of equipment for nuclear powerplant took place in late 1970's. A large number of originally installed equipment is obsolete. The manufacturer's do not support their products or have discontinued their production due to technological evolutions or lack of product demand. Lack of spares affects the performance of obsolete equipment and has a negative impact on plant safety and plant production. A proactive approach to address obsolescence is necessary to ensure critical spares are always available when needed. This is an ongoing effort and requires a program to be in place to resolve immediate and longterm issues. A cross-functional team with adequate external exposure is needed to administer the obsolescence program. CANDU utilities and CANDU Owners Group(COG) has taken initiatives to identify lack of equipment spares in the members' plant. The equipment ...
Solar heating of gas turbine plants steps back more and more into the focus of current research. The mainly instationary operation of solar turbine powerplants can only be predicted with sufficient accuracy if the transient behaviour of the receiver for the solar radiation is known. Therefore the transient behaviour of cavity receivers of different design is investigated. The mathematical model used for the simulation of the heat transfer and energy storage processes is illustrated. Computed results for receivers with various inner lining are compared and evaluated concerning their use in practice.
Solar heating of gas turbine plants is moving back to the focus of current research. The mainly unsteady operation of solar turbine powerplants can only be predicted with sufficient accuracy if the transient behavior of the solar radiation receiver is known. Therefore the transient behavior of cavity receivers of different designs is investigated. The mathematical model used to simulate heat transfer and energy storage is illustrated. Computed results for two receivers with different inner lining are compared and evaluated concerning their use in practice.
In this handbook, technical reports on a number of hydro plants under construction are provided. In addition tables of compiled data are presented on a world-wide basis for the following: turbine and hydro generator contracts; hydropower resource potential and development; pumped storage plants; the major dams and hydro plants; roller compacted concrete dams and concrete faced rockfill dams; small hydropower. An address database of international organizations of relevance to hydropower development, national power authorities and nation committees of the International Commission an Large Dams is included. A final and major section of the handbook is a buyer's guide providing extensive company data and information on products and services. (UK)
This very significant and useful report assessed state-of-the-art geothermal technologies. The findings presented in this report are the result of site visits and interviews with plant owners and operators, representatives of major financial institutions, utilities involved with geothermal power purchases and/or wheeling. Information so obtained was supported by literature research and data supplied by engineering firms who have been involved with designing and/or construction of a majority of the plants visited. The interviews were conducted by representatives of the Bonneville Power Administration, the Washington State Energy Office, and the Oregon Department of Energy during the period 1986-1989. [DJE-2005
The integration of a gas turbine into a new type of coal-fired combined cycle powerplant necessitates a multiplicity of far-reaching changes compared with a normal design. The extremely high pre-heating temperature of the air emanating from the heat exchanger of the fluidized bed for the gas turbine combustion chamber has necessitated extensive development work and associated combustion trials. It was possible for these results to influence the design of the burners whereas the manufacture of other components which was on the critical path was already far advanced.
The Michigan Electric Coordination Center (MEPCC), operated by Consumers Power and Detroit Edison Companies, has the responsibility for scheduling the Ludington pumped storage plant. Ludington has an extremely large economic effect on the Consumers Power and Detroit Edison Companies' system due to its size (over 1800 MW net demonstrated generating capability). This paper presents a dynamic programming algorithm for scheduling large pumped storage plants and shows how this method can be coordinated with the commitment of the thermal units of the system.
Those areas in California where synthetic fuel-fired powerplants could be sited in the 1990 time frame, from an air quality perspective were identified. The synfuel-fired powerplants considered in this new study were 500 MW methanol-fired combined cycle (MFCC) and 500 MW integrated gasifier combined-cycle (IGCC) units. For comparison purposes, 500 MW direct coal-fired boilers and 500 MW natural gas-fired combined-cycle units were also considered. The study provides an approximation, for planning purposes, of a reasonable limit of the state's powerplant siting capacity, given the plant types and sizes, conditions, and assumptions specified. The study shows that local emission limitations many times preclude certain types of powerplants even when they are equipped with Best Available ...
The object of this study was to identify those areas in California where synthetic fuel-fired powerplants could be sited in the 1990 time frame, from an air quality perspective. The synfuel-fired powerplants considered in this new study were 500 Mw methanol-fired combined cycle (MFCC) and 500 Mw integrated gasifier combined-cycle (IGCC) units. For comparison purposes, 500 Mw direct coal-fired boilers and 500 Mw natural gas-fired combined-cycle units were also considered. Staff did not attempt to locate plants at any specific sites, but relied primarily upon a regional countywide analysis. The study provides an approximation, for planning purposes, of a reasonable limit of the state's powerplant siting capacity, given the plant types and sizes, conditions, and assumptions specified. The study shows that local ...
Comments are made on the Public Inquiry into CEGB's proposal to construct a pressurized water reactor (PWR) at Sizewell, UK. Aspects discussed include: time elapsed and its possible effect on the result; economics of nuclear powerplants compared with coal-fired powerplants; changes in real sterling/dollar exchange rates; effect of mineworkers' strike; the UK electric power generating system; AGR reactors compared with PWR reactors; extension of Magnox reactor life; radioactive waste management; political decisions.
The regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from January 7 to February 8, 1985. The summary of the results of this regular inspection is as follows. The facilities as the object of inspection were radiation control facilities and waste facilities. On these facilities as the object of inspection, the appearance, disassembling, functional, performance and other inspections were carried out, and as the results, abnormality was not found at all. The works related to this regular inspection were accomplished within the range of the allowable radiation dose based on the relevant laws. (Kako, I.).
Voestalpine AG (Linz, Austria) produces heavy steel for steam turbines, compressors for the promotion of oil and gas as well as for the chemical industry, mechanical engineering and for the offshore technology. A weight range between 1 and 200 tons can be covered. The author of the contribution under consideration is limited to characteristics which have to be managed by a large steel foundry within the range of the steam powerplants. This is described on the basis of produced steam turbines for power stations in the highest performance segment (1,600 MW).
This document contains the accident sequence analysis of internally initiated events for Grand Gulf, Unit 1 as it operates in the Low Power and Shutdown Plant Operational State 5 during a refueling outage. The report documents the methodology used during the analysis, describes the results from the application of the methodology, and compares the results with the results from two full power analyses performed on Grand Gulf.
A study of advancements in powerplant designs for use at geothermal resources in the low to moderate (300 to 400F) temperature range is reported. In 3 case studies, the benefits of R and D to achieve these advancements are evaluated in terms of expected increases in installed geothermal generating capacity over the next 2 decades. A parametric sensitivity study is discussed which analyzes differential power development for combinations of powerplant efficiency and capitol cost. Affordable tradeoffs between plant performance and capital costs are illustrated. The independent review and analysis of the expected costs of construction, operation and maintenance of the Heber Binary Cycle Geothermal Power Demonstration Plant are described. Included in this assessment is an analysis of each of the major cost components of the ...
Traditionally, probabilistic risk analyses [PRA] of severe accidents in nuclear powerplants have limited themselves to consideration of the set of initiating events occurring during full power operation. However, some analyses of accident initiators during low power, shutdown, and other modes of plant operation other than full power have been performed. These studies as well as the Chernobyl accident and recent operating experience at U.S. pressurized water reactors suggested that risks during low power and shutdown could be significant. As such, the analysis of the frequencies, consequences, and risks of these accidents was identified as one task in the Nuclear Regulatory Commission staff's study of the implications of the Chernobyl accident to U.S. commercial nuclear powerplants. The surry PRA ...
Topics related to aerospace power are discussed, taking into account trends and issues of military space power systems technology, space station power system advanced development, the application and use of nuclear power for future spacecraft, the current status of advanced solar array technology development, the application of a parabolic trough concentrator to space station power needs, life test results of the Intelsat-V nickel-cadmium battery, and metal hydride hydrogen storage in nickel hydrogen batteries. Other subjects explored are concerned with alternative fuels, biomass energy, biomedical power, coal gasification, electric power cycles, and electric propulsion. Attention is given to an advanced terrestrial vehicle electric propulsion systems assessment, fuel cells as electric propulsion power ...
An Ottawa-based company, ECS-Power Systems Inc., has successfully completed a series of tests on an innovative device called a hydrodynamic port (HDP), which makes it possible to automatically initiate and maintain emergency cooling of a nuclear reactor core by natural processes, without relying in any way on human intervention, instrumentation, electric power, valves or moving parts of any kind.
By way of introduction, the author describes the electrical equipment of the power station on the River Traun and then lists the main features of the electrical systems such as generators, transformers, the power transmission systems as, e.g., the generator leads, the 8 kV switch plant, the 110 kV oil-filled cable as well as the station-service, control, protection and monitoring systems. The control of the headwater level and of the mechanical systems of the barrage is described in detail.
In connection with the Public Inquiry into the CEGB proposal to build a pressurised water reactor at Sizewell in Suffolk, the case for nuclear power is examined under the headings: the economics of nuclear power - how they would like them to be; systems analysis - net effective cost; CEGB prejudices the results (comparison with coal-fired plants; forecasting on various assumptions); discounting future costs; back-end costs soar (reprocessing); real reprocessing costs; AGR costs balloon.
The Electric Power Research Institute has published a report for planners, designers, owners, and operators of hydroelectric pumped-storage plants that records the operation and maintenance knowledge of 35 domestic and foreign pumped-storage projects. The report provides a comprehensive record of practices that have reduced forced outages and shortened scheduled repairs. As time passes and experienced staff retire at pumped-storage plants, many O M lessons are lost. To remedy that situation, EPRI commissioned Morrison-Knudsen Engineers Inc. to prepare a special report. The 348-page publication records the accumulated civil, geotechnical, mechanical, and electrical O M knowledge and experiences of pumped-storage plant staff. It also includes recommendations to planners and designers of future pumped-storage plants and concludes with descriptions of O M experiences reported by ...
This paper develops optimal bidding strategies for a pumped-storage plant in a pool-based electricity market. In the competitive regime, when compared to simple hydroelectric generator, profit of the pumped-storage plant is maximized by operating it as a generator when market clearing price is high and as a pump when the price is low. Based on forecasted hourly market clearing price, a multistage looping algorithm to maximize the profit of a pumped-storage plant is developed, considering both the spinning and non-spinning reserve bids and meeting the technical operating constraints of the plant. The proposed model is adaptive for the nonlinear three-dimensional relationship between the power produced, the energy stored, and the head of the associated reservoir. Different operating cycles for a realistic pumped-storage plant are considered and simulation results ...
A scheme for on-line tuning of a fuzzy-logic power system stabilizer is presented. firstly, a fuzzy-logic power system stabilizer is developed using speed deviation and accelerating power as the controller input variables. The inference mechanism of fuzzy-logic controller is represented by a decision table, constructed of linguistic IF-THEN rules. The Linguistic rules are available from experts and the design procedure is based on these rules. It assumed that an exact model of the plant is not available and it is difficult to extract the exact parameters of the powerplant. Thus, the design procedure can not be based on an exact model. This is an advantage of fuzzy logic that makes the design of a controller possible without knowing the exact model of the plant. Secondly, two scaling parameters are introduced to tune the fuzzy-logic ...
The competitiveness of a new nuclear plant vs. a new oil or gas fired combined cycle plant or a coal fired plant in East-Asia, is reviewed in the paper. Both the nuclear and the fossil fired plants are evaluated as either utility financed or independent power producer (IPP) financed. Two types of advanced light water reactors (ALWRs) are considered in this paper, namely evolutionary ALWRs (1200 MWe size) and passive ALWRs (600 MWe class). A range of capital and total generation costs for each plant type is reported here. The comparison centers on three elements of overall competitiveness: generation costs, hard currency requirements, and employment requirements. Each of these aspects is considered perspective. Year-by-Year generation cost history over the plant lifetime is shown in some cases. It is found here that a utility financed ...
The paper is concerned with the economic operation of power systems comprising pumped storage and thermal plants. In power systems, pumped storage plants may receive the energy required for pumping water either from the system in which they are integrated or from a neighbouring system. Therefore, two mathematical formulations of the problem are presented depending on the source of energy during pumping. In both cases, the problem is reduced to a non linear optimization problem. Two numerical techniques are suggested for the solution of this optimization problem, namely the Lagrangian Multipliers technique and the Rosen Gradient Projection technique. Numerical examples are presented to demonstrate the techniques. Although the Lagrangian Multipliers technique has the advantage of being a well known technique, however, computer wise, the Rosen Gradient Projection technique proves to be more efficient. The ...
This report describes the arrangement and features of the Ogishima thermal powerplant facilities, as well as activities being performed there for operation control, regular inspection and improvement in reliability. The powerplant uses about 48 percent of the by-product gas as its fuel to supply about 81 percent of the required power. Operation of the No. 1 unit started in 1976. Currently, the plant has three units, each with an output of 125MW. Each unit consists of a natural circulation boiler with a maximum evaporation capacity of 410 ton/hour and a reheat regenerative condensing turbine with a main vapor pressure of 127 kg/cm/sup 2/G. Techniques used for water properties control and combustion control are also described. In the plant, convetional time management integrity techniques are now being replaced by state management integrity ...
Over the past few years, NPCIL has performed comprehensive Level-1 Probabilistic Safety Assessment (PSA) for a 220 MWe Pressurised Heavy Water Reactor (PHWR) at Kakrapar Atomic Power Station (KAPS) and for the first 540 MWe PHWR at Tarapur Atomic Power Project (TAPP- 3 and 4). The major objective of these PSAs was to present an integrated picture of the safety of the plant to identify and understand key plant vulnerabilities. As a result of the availability of these PSAs, there is a desire to use them to operate the plants in the most efficient manner practicable. In recent years, the operation of Indian Nuclear PowerPlants has been characterized by improved availability/capacity factors and reduced forced outages. Frequency of planned outages is also being reduced. In order to achieve this, the PSAs are now being used as an engineering ...
Powerplant components exposed to environments such as water and soil are susceptible to severe corrosion. Many times the effect of corrosion in powerplant components can be catastrophic. The problem is aggravated for underground pipelines due to additional factors such as large network of pipelines, proximity to earth mat, high voltage transmission lines, corrosive chemicals, inadequate approach etc. Other components such as condenser water boxes, internals of pipelines, clarifier bridge structures, cooling water inlet gates and pipes etc. which are in continuous contact with water, are subjected to severe corrosion. The nature and locations of all such components are at places which are not accessible for routine maintenance and hence they require long term reliable protection against corrosion. Experience has shown that anti-corrosive coatings are inadequate in preventing corrosion and due to their ...
Research and development activities sponsored by countries within the International Energy Agency`s solar thermal working group. SolarPACES, have helped reduce the cost of solar thermal systems to one-fifth that of the early pilot plants. Continued technological improvements are currently being proven in next-generation demonstration plants. These advances, along with cost reductions made possible by scale-up to larger production and construction of a succession of powerplants, have made solar thermal systems the lowest-cost solar energy in the world and promise cost-competitiveness with fossil-fuel plants in the future. Solar thermal technologies are appropriate for a wide range of applications, including dispatchable central-station powerplants where they can meet peak-load to near-base-load needs of a utility, and distributed, modular ...
Argentina has two operating PHWR nuclear powerplants. Atucha I NPP is a pressure vessel type heavy water reactor of 360 MW e with 25 years of operation and Embalse NPP is a pressure tube type CANDU-600 reactor of 640 MW e. Atucha II, a third plant of 600 MW e of the pressure vessel type similar to Atucha I, is being constructed. NASA (Nucleoelectrica Argentina S.A.) currently operates both nuclear powerplants. The National Atomic Energy Commission (Comision Nacional de Energia Atomica - CNEA) provides operational support to the plants, including research and development assistance, and actual technical services and maintenance work in different areas. The Chemistry Department, formerly the Reactor Chemistry Department has carried out project and support activities to the plants during the past 20 years. The aim of this work is to describe ...
For the conversion of thermal energy into electric energy in modern condenser powerplants, according to the way of steam generation, two different types of power stations are built: power stations for fossile fuels and nuclear power stations. Also two classes of steam turbines were developed, corresponding to the two power station types, whose steam conditions, by experience and extensive calculations of economy, were determined so that a minimum of power generating cost will result. The two classes, the HMN and the SN series, are composed according to the modular system and designed in such a manner that with a small number of standard components, steam turbines for the power range between 100 and 2,500 MW can be built. (orig.).
The Belgian Tihange 2 nuclear powerplant went into commercial operation in 1983 producing a thermal power of 2785 MW. Since the commissioning of the plant the steam generators U-tubes have been affected by primary stress corrosion cracking. In order to avoid further degradation of the performance and an increase in repair costs, Electrabel, the owner of the plant, decided in 1997 to replace the 3 steam generators. This decision was supported by the feasibility study performed by Tractebel Energy Engineering which demonstrated that an increase of 10% of the initial power together with a fuel cycle length of 18 months was achieved. Tractebel Energy Engineering was entrusted by Electrabel as the owner's engineer to manage the project. This paper presents the role of Tractebel Energy Engineering in this project and the safety analysis program necessary to justify ...
Nuclear powerplant has several safety features and each safety feature is based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear powerplant to keep operational readiness of pumps and valves by In-Service Test (IST). According to Ministry of Education, Science and Technology (MEST) Bulletin 2008-14, the safety functioned pumps and valves of all nuclear powerplants of Korea Hydro and Nuclear Power Co. Ltd.(KHNP) have been tested to verify their performance of safety function. Each safety grade pump has own design requirement and should be tested to identify whether it could meet the requirement. Design requirements and test references of all safety grade pumps of Wolsung Nuclear PowerPlant Unit 2 (Wolsung Unit 2) were examined in this study. And ...
Nuclear powerplant has several safety features and each safety feature is based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear powerplant to keep operational readiness of pumps and valves by In-Service Test (IST). According to Ministry of Education, Science and Technology (MEST) Bulletin 2008-14, the safety functioned pumps and valves of all nuclear powerplants of Korea Hydro and Nuclear Power Co. Ltd.(KHNP) have been tested to verify their performance of safety function. Each safety grade pump has own design requirement and should be tested to identify whether it could meet the requirement. Design requirements and test references of all safety grade pumps of Wolsung Nuclear PowerPlant Unit 2 (Wolsung Unit 2) were examined in this study. And ...
In Romania, the nuclear power is an element of sustainable development, being competitive, efficient and viable in the market economy. Fuel supply is ensured as nuclear fuel is manufactured in the country out of local uranium resources available in Romania. As for the environmental protection, it is known that, unlike the thermal powerplants, the nuclear powerplants do not release sulfur and nitrogen oxides, carbon dioxide and do not generate slag and ashes. The operation of nuclear power units does not release pollutants and, accordingly, these stations can contribute to the limitation and the abatement of environmental pollution. After seven years of Cernavoda NPP Unit 1 operation, a facility for storing low and medium level nuclear fuel wastes was built at the plant site as well as an intermediate dry storage for spent nuclear fuel ...
A linear induction accelerator that produces a beam of energetic heavy ions (T -- 10 GeV, A -- 200 amu) is a prime candidate as a driver for an inertial fusion powerplant. Some early perceptions were that heavy-ion drive fusion would not be cost-competitive with other power sources because of the high cost of the accelerators. However, improved understanding of the physics of heavy-ion transport and acceleration (supported by experimental results), combined with advances in accelerator technology, have resulted in accelerator design costs -- 50% of previous estimates. As a result, heavy-ion drive fusion powerplants are now projected to be cost-competitive with other conceptual fusion powerplants. A brief formulation of transport and acceleration physics is presented here, along with a description of the induction Linac cost optimization ...
A linear induction accelerator that produces a beam of energetic heavy ions (T #approx =# 10 GeV, A #approx =# 200 am#mu#) is a prime candidate as a driver for an inertial fusion powerplant. Some early perceptions were that heavy-ion driven fusion would not be cost-competitive with other power sources because of the high cost of the accelerators. However, improved understanding of the physics of heavy-ion transport and acceleration (supported by experimental results), combined with advances in accelerator technology, have resulted in accelerator design costs -- 50% of previous estimates. As a result, heavy-ion driven fusion powerplants conceptual fusion powerplants. A brief formulation of transport and acceleration physics is presented here, along with a description of the induction Linac cost optimization code LIACEP. Cost trends are ...
Restructured power markets require concepts not only for extending the lifetime of existing plants, but also concepts for reducing the life-cycle costs of existing older steam powerplants in order to remain competitive with the most modern and advanced power generation technology such as combined cycle powerplants. Out of the broad range of methods to extend service life and increase availability, and to increase power output and efficiency, this paper focuses on full repowering. Full repowering replaces the old fired boiler with gas turbine(s) and heat-recovery steam generators (HRSG) as heat input to the existing bottoming cycle and reuses the steam turbine (ST) condenser and further balance of plant (BOP) equipment. The potential offered by this concept is demonstrated. Repowering and ...
This Final Environmental Impact Statement and Environmental Impact Report (Final EIS/EIR) has been prepared to meet the requirements of the National Environmental Policy Act (NEPA) and the California Environmental Quality Act (CEQA). The Proposed Action includes the construction, operation, and decommissioning of a 48 megawatt (gross) geothermal powerplant with ancillary facilities (10-12 production well pads and 3-5 injection well pads, production and injection pipelines), access roads, and a 230-kilovolt (kV) transmission line in the Modoc National Forest in Siskiyou County, California. Alternative locations for the powerplant site within a reasonable distance of the middle of the wellfield were determined to be technically feasible. Three powerplant site alternatives are evaluated in the Final EIS/EIR.
We find dosage of gamma emitters radionuclides of samples collected in the environment of the Chinon nuclear powerplant for 2002 and 2003, these results are presented in two tables: concentrations in gamma emitter radionuclides of samples collected in the terrestrial environment (soils) and aquatic environment (sediments) of the site of Chinon in june 2002 in the frame of the annual surveillance, the second table concerns the concentrations in gamma emitter radionuclides of samples collected in the terrestrial environment (soils and lichens) of the site of Chinon in may 2003 in the frame of the annual surveillance. We find also the dosage of free tritium in the water of the Loire river for 2002 and 2003, upstream and downstream to the powerplant of Chinon. (N.C.)
In the last few years the management of nuclear powerplants as well as the supervising administration of the nuclear industry in Germany has focused more on emergency preparedness. The skills have been improved, but there are also improvements under way, yet. The study gives an overview about the status of emergency preparedness in German powerplants, about the legal framework for emergency preparedness and about the elements of an effective emergency preparedness planning. However, it does not deal with technical accident management but with the organisational aspects of emergency planning. Also, the study gives a short outlook for future trends of development in the field of emergency preparedness in Germany. Major trends are the standardisation of organisational concepts, more training and more national and international feed back of know how on the topic. Yet, there is still some research work to ...
The steam generator is a very important component of a nuclear powerplant. Historically, vertical steam generators came to be used abroad and horizontal steam generators in our country. Both types of steam generators operate successfully in nuclear powerplants and satisfactorily fulfill their functions, enabling the production of electricity. Repeated attempts to re-examine the existing concepts in one or another country have been unsuccessful because there are no convincing arguments for this. Nonetheless, the question of using a different type of steam generator is raised periodically in our country and abroad. This article briefly reviews different concepts of steam generators. Their parameters, characteristics, and thermal efficiency are compared and ways to increase the latter are a...
Presented here is the calculation results of tidal field of Daya Bay by using pseudospectral method. According to the calculation results about the tidal field and measured value of wind in Daya Bay area, the diffusion of radionuclide from Daya Bay Nuclear PowerPlant is simulated by using particle random walk model. The simulation results about the relative concentration distribution of the radionuclides and the trajectory of the distribution centrode are obtained, taking account of tidal current, wind and turbulent current. These results can provide information not only for the reasonable discharge of the radionuclides from Daya Bay Nuclear PowerPlant, but also for understanding the potential effect on environment due to the normal operation of Daya Bay Nuclear PowerPlant. (authors)
The research committee of the Atomic Energy Society of Japan on water chemistry standard aims at establishing the private standard of water chemistry of nuclear powerplants. The committee gathers up 'BWR water chemistry management manual', 'PWR primary system water chemistry management manual' and 'PWR water chemical analysis standard method', and furthermore aims at the standardization of those in future. Looking back on the committee's activities for the past four years, latest results of research of water chemistry mainly contributing to safe and reliable nuclear powerplants were described with the future perspective of water chemistry and a demanded break-through. (T.T.)
Based on the air pollution values typical of brown coal furnaces the paper discusses pollution abatement measures on the part of fuel engineering and flue gas technology. Fuel engineering contributes to air pollution abatement by measures such as stepped air supply, stepped fuel supply and flue gas draw-in. Flue gas technology largely relies on measures such as the SCR method using different catalytic converters, the noncatalytic reduction of nitrogen oxides, the simultaneous separation of sulfur dioxides and nitrogen oxides, and the Denox-Luvo method. The paper concludes with remarks on the RWE brown coal powerplant retrofitting scheme planning to have all powerplants equipped with adequate denitrification systems until the end of 1989 at the latest. (orig./PW)
Operation and maintenance cost estimating methodologies for advanced coal-fired atmospheric circulating fluidized-bed and advanced natural gas-fired combined cycle electric powerplants are presented. The purpose of these cost estimating relationships is for use in long range planning and evaluation of the economics of use of these technologies for electric power generation. Projected annual costs of reference plants at ten different sites in the United States, one in each of the ten DOE regions, are given as of 1989, and comparisons are made with existing technologies. A listing of a computer program implementing the methodologies is included. 14 refs., 4 figs., 13 tabs.
Technology transfer is an integral part of Framatome's general approach to its Chinese partners for the Daya Bay, Ling Ao, and Qinshan phase 2 nuclear powerplant projects. It has been the subject of major operations covering all activities relevant to project management, design and engineering, manufacturing, and maintenance know-how. This presentation is more particularly devoted to nuclear island maintenance knowledge, which has been extensively transferred by Framatome to the Daya Bay plant owner over a period of four years, through a program including the constitution of mixed Franco-Chinese teams to handle plant maintenance, shadow training of Chinese specialists in the maintenance work performed by Framatome or its subcontractors in France, and theoretical training sessions on equipment mockups in China and France. (author)
In order to perform the structural analysis and stress evaluation for frame structures in the nuclear powerplants, ADAMS (AIJ Design Analysis and Modules System) has been developed by the addition of the following functions to the ICES-STRUDL system. 1. Load combination and stress evaluation on the basis of specifications for designing steel structure (issued by the Architecture Institute of Japan). 2. Combination of load and stress evaluation of piping support on the basis of the regulations of Ministry of International Trade and Industry. 3. Addition of other functions than that described above. ADAMS enables structural analysis and stress evaluation exactly and efficiently not only for a large scale structure such as the pipe whip protection structure installed inside of the primary containment vessel for many loading cases but also for a large number of structures such as piping support. This system can be applied not only to nuclear ...
Cooling waters from eleven geographically disparate powerplants were tested for the presence of Naegleria fowleri and Legionella pneumophila (LDB). Control source waters for each plant were also tested for these pathogens. Water from two of the eleven plants contained pathogenic Naegleria, and infectious Legionella were found in seven of the test sites. Pathogenic Naegleria were not found in control waters, but infectious Legionella were found in five of the eleven control source water sites. Concentrations of nitrite, sulfate, and total organic carbon correlated with the concentrations of LDB. A new species of Legionella was isolated from one of the test sites. In laboratory tests, both Acanthamoeba and Naegleria were capable of supporting the growth of Legionella pneumophila.
This paper presents a new application in dynamic voltage control based on an older method of voltage regulation. The resulting method is suitable for adoption inn multi-unit pumped storage plants. Inherent operation characteristics of pumped storage plants in the pumping mode can created visible load rejection overvoltages on the transmission and the nearby distribution networks and cause customer complaints. This paper proposes a method in which the on-line units' excitation system impedance compensators are utilized to reduce the magnitude of these overvoltages. This paper presents the theoretical background, computer simulation results, and the field test results at the Pacific Gas and Electric Company's Helms Pumped Storage Plant. This paper should be of interest in the areas of power system planning as well as power system operation.
Most pumped-storage plants have the capability to operate as synchronous condensers. As such, they can be brought on line very quickly to support system load requirements. However, one of the effects of making a rapid transition from synchronous condenser operation to turbine/governor operation is an initial reverse power flow into the machine. This reverse power flow can be very undesirable at a time when the system is calling for load support. On weak or isolated systems, this reverse power flow can lead to objectionable voltage and frequency dips in the system. With the proper utilization of a static frequency converter (SFC) and its associated controls and auxiliary switchgear systems, the reverse power flow resulting from a transition from synchronous condenser operation can be eliminated. This paper will describe the method by which an SFC system can be used to make this rapid ...
The Nuclear Safety Commission acknowledged the policy of the Agency of Natural Resources and Energy to cope with these important matters on August 8, 1984. The main contents of the investigation and deliberation were as follows, As to the prevention of the occurrence of fires, the prevention of the leak and spread of inflammable liquid and gas, the installation of protective relays and so on, the use of incombustible materials and aseismatic design and the installation of lightning arresters. As to the detection of fires and fire fighting, the proper selection and arrangement of fire detectors and extinguishers, the extinguishers which do not harm the safety function of structures and equipment, and the extinguishers which are not affected by natural phenomena. As to the reduction of the effect of fires, the proper installation of fire walls and extinguishers, and the high temperature shut off of nuclear reactors which is never hampered by any fire. (Kako, I.).
The power industry is undergoing major changes. Deregulation and a competitive climate demand effective solutions. Costs and losses must be reduced, and overall efficiency must be raised. Industrial options connected to energy market and environmental considerations are discussed. Themes discussed in this paper are environmental challenges, the fuel factor, powerplants in use today, the Norwegian power system, the European system, power exchange across borders, the transmission system, the future European system, and options for Norwegian industry. 27 figs.
Constantly increasing resource efficiency together with the broad introduction of CCS technologies is fundamental for a continuous use of fossil fuels in power generation against the background of up-coming requirements for CO2 emission reduction. In principle, CCS means up-grading conventional powerplant technology with proven CO2 removal processes. However, this leads to additional losses, auxiliary power demand and cost. System integration, development or at least adaption of components and processes are the main requirements in this context. Different technology solutions and recent developments will be addressed as well as challenges when implementing in demonstration projects.
A top-level costing model is developed and used to project the cost of electricity (COE) (in mills per kilo watt-hour) expected from conceptual fusion powerplants. Application is restricted to magnetic fusion energy (MFE) concepts. These costs are estimated parametrically in terms of the mass of the fusion-power-core (FPC) heater, the power required to sustain a reacting deuterium-tritium plasma, the heat transport/transfer system that delivers the fusion power to the balance of plant (BOP), and the BOP needed to convert the fusion heat to electrical power. Although the highly integrated (simplified) cost-estimating relationships (CERs) used to express COE in terms of FPC mass power density (MPD) [in kilowatt(electric) per tonne] and the engineering gain Q{sub E} (inverse of fraction of gross electric ...
Tritium occurs in nature in trace amounts, but its concentration is changing due to natural and artificial sources. Studies focusing on natural tritium have to take into account the effect of artificial sources. Also, the impact of tritium is an important issue in environmental protection, e.g. in connection with the emissions from nuclear powerplants. The present work focuses on the rain washout of tritium emitted from the Paks nuclear powerplant in Hungary. Rainwater collectors were placed around the plant and after a period of precipitation, rainwater was collected and analysed for tritium content. Samples were analysed using low-level liquid scintillation counting, with some also subject to the more accurate "3He ingrowth method. The results clearly show the trace of the tritium plume emitted from the plant; however, values are only about one order of ...
Compared with that of Daya Bay Nuclear PowerPlant, the reactor power of QS-II Nuclear PowerPlant is decreased and the primary coolant system is changed from three loops to two loops. Thereby the related systems were re-designed, and corresponding tests and engineering validation were carried out. Results of preliminary operation indicate that it is successful. The author describes the design modifications, features and corresponding tests of some systems, reflecting the successful incorporation of engineering and testing, and revealing the capability to develop nuclear power and design the large or medium sized commercial NPP on Self-Reliance in China
Severe accident analysis has been performed for the Wolsung nuclear power= plants in Korea to investigate severe accident phenomena of CANDU-600 reactors as a part of Level II PSA study. The accident sequence analyzed in this paper is loss of active heat sinks (LOAH) which is caused by loss of off-site power, diesel generators, and DC power. ISAAC (Integrated Severe Accident Analysis Code) computer code developed by KAERI (Korea Atomic Energy Research Institute) was used in this analysis. This paper describes the important thermal-hydraulics and source term behaviors in the primary system and inside containment, and the failure mechanisms of calandria vessel and containment. In addition, some insights for accident management program (AMP) are also given. (Author) 5 refs., 1 tab., 12 figs.
A stable power system stabilizer (PSS) based on the inverse dynamics of the controlled system using an artificial neural network (ANN) is suggested to enhance the dynamic performances of a power system. First, an output feedback control law is driven with some conditions satisfied, which guarantees the internal stability and robustness against the asymptotically stable external disturbances. Then the control law is implemented using the inverse dynamics of the controlled plant. The inverse dynamics of the controlled plant is identified by an ANN, inverse dynamics neural network (IDNN), off-line. The pole-shifting technique and a scaling factor are introduced for the control system to meet the conditions for internal stability and robustness. The proposed controller is applied to a typical single-machine infinite-bus power system. Simulation results under various operation conditions ...
A consequent use of computers and standardized components enables high efficiency for steam turbines while produced at lower manufacturing cost as shown here in the Muehlheim company of Siemens Power Generation, where steam turbines are produced for new stations and retrofitted elder powerplants. [German] Auch eine ueber hundert Jahre alte Technik bietet Raum fuer Innovationen: Konsequenter Computereinsatz und standardisierte Baureihen ermoeglichen bei Dampfturbinen hohe Wirkungsgrade bei relativ niedrigen Fertigungskosten - umgesetzt im Werk Muelheim der Siemens Power Generation, wo Dampfturbinen fuer Neuanlagen und zum Modernisieren bestehender Kraftwerke entstehen. (orig.)
Rapid technology improvements, resulting in high efficiency, emissions reduction and low generation cost, are making gas turbines the generation technology of choice despite some recent reliability problems. The basic reason for the dominance is high efficiency. The rapid pace of gas-turbine technology improvement in the 1990s drove combined-cycle thermal efficiency to nearly 60 percent with natural gas as the fuel. It will probably go even higher after the year 2000. In addition, the gas-fired combined cycle is a bargain. With natural gas prices where they are right now, it is the least-cost generation operation for power producers with access to gas. Many will replace older, high-cost powerplants with new gas-fired combined cycle powerplants.
The authors explain the bankers' point of view of the financial and economic aspects of developments in the energy sector, discussing the financing of natural gas pipelines (Muro, Megal, etc.), of nuclear powerplant construction, of projects in the oil supply sector, and of pollution abatement measures and equipment for the power industry and other industries. The different financial situations of small firms or large firms supplying pollution control equipment are discussed referring to the financing schemes to be set up, explaining among other things the profitability assessment taking into account long-term development or delays in return on capital investment from borrowed funds as induced, e.g., by delays in the licensing procedure. Future demand for borrowed capital for pollution control or nuclear powerplant development is difficult to assess by the banking ...
Inputs on radiological conditions forms the basis of implementation of effective exposure control to plant personnel in nuclear power station. Radiation monitoring system provides this input to the plant operator as well as to health physics group. Several design modifications have been incorporated in the Radiation Monitoring System at Tarapur Atomic Power Station (TAPS 3 and 4) over the similar systems at Kakrapar Atomic Power Station (KAPS) and Kaiga Generating Station (KGS). The radiological monitoring systems installed at TAPS unit 3 and 4 includes on line Radiation Data Acquisition System (RADAS), Emergency sampling system, effluent monitoring system and environmental monitoring system. The design changes and the versatile use of these systems are presented in this paper. (author)
It is described a process of production of celulignin from biomass through acid pre-hydrolysis in continuous reactor made of advanced materials such as niobium, titanium and monel. The celulignin is a fuel of 28.50 MJ/kg of heating power. The utilization of this technology together with eucalyptus reforestation by vegetative propagation and high efficiency thermoelectric plant (triple cycle of steam turbine, gas turbine and MHD electrical generation) allow electric power production with competitive cost when compared to hydroelectric power. (author). 1 ref. 5 figs., 2 tabs
A power system stabilizer based on GMV (Generalized Minimum Variance), one of the adaptive control techniques, is developed to enhance the dynamic performances of a power system using an Artificial Neural Network (ANN). The stabilizer consists of two parts. One part is Inverse Dynamics Neural Networks (IDNN), which is trained to identify the inverse dynamics of controlled plant and used as a one-step ahead controller, or inverse controller. The other part is Adaptive Reference Model (ARM), which prevents excessive controller output. The ARM produces the modified reference value by minimizing a cost function recursively on the assumption that the IDNN perfectly identifies the controlled plant. The IDNN is used in the minimization procedure to calculate the sensitivities. The proposed controller is simulated in a typical one-machine-infinite-bus power system to show its effectiveness ...
The deliveration by the Nuclear Safety Commission was commenced on the alteration in reactor installation, as it had been inquired by the Ministry of International Trade and Industry. The alteration is the additional installation of the reactor No. 2 in the Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc. It is a PWR powerplant with thermal output of about 2,660 MW (electric output of 890 MW), to be installed, adjoining to the reactor No. 1 of the same type and capacity under construction. In the examination by MITI, it was confirmed that the technological capabilities for its construction and operation and the radiation protection measures in power generation are both sufficient. The contents of the examination include the siting conditions, the location and construction of reactor facilities, etc. (J.P.N.).
The deliberation by the Nuclear Safety Commission was initiated on the alteration in reactor installation, as was required by the Ministry of International Trade and Industry. The alteration is the additional installation of the reactor No. 2 in the Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc. It is a PWR powerplant with thermal output of about 2,660 MW (electric output of 890 MW), to be installed, adjoining to the reactor No. 1 of the same type and capacity under construction. In the examination by MITI, it was confirmed that the technological capabilities for its construction and operation and the radiation protection measures in power generation are both sufficient. The contents of the examination include the siting conditions, the location and construction of reactor facilities, etc.
By retrofitting the existing steam turbine dual purpose powerplant with a gas turbine plant and a secondary waste heat boiler the Technische Werke Ludwigshafen AG have considerably improved the energy generation in energetic, economic and ecological terms. The extension of the existing system to a combined cycle process has lead to this positive effect. The erection of a boiler plant during the first two construction phases has fully met the optimistic expectations. (orig.) [Deutsch] Mit der Nachruestung eines vorhandenen Dampfturbinen-HKW um eine Gasturbinenanlage mit nachgeschaltetem Abhitzekessel haben die Technischen Werke Ludwigshafen AG ihre Energieerzeugung entscheidend in energetischer, oekonomischer und oekologischer Sicht optimiert. Insbesondere die Erweiterung des vorhandenen Systems zu einem GuD-Prozess fuehrt zu dieser positiven Bilanz. Die Errichtung der Kesselanlage in den ersten beiden ...
The requirements to design nuclear powerplants for the effects of an instantaneous double-ended guillotine break (DEGB) of the reactor coolant piping have led to excessive design costs, interference with normal plant operation and maintenance, and unnecessary radiation exposure of plant maintenance personnel. This report describes an aspect of the NRC/Lawrence Livermore National laboratory-sponsored research program aimed at investigating whether the probability of DEGB in Reactor Coolant Loop Piping of nuclear powerplants is acceptably small such that the requirements to design for the DEGB effects (e.g., provision of pipe whip restraints) may be removed. This study estimates the probability of indirect DEGB in Reactor Coolant piping as a consequence of seismic-induced structural failures within the containment of the GE supplied boiling water reactor at the ...
The NUclear Power Engineering Corporation (NUPEC) has developed IMPACT-SAMPSON code to analyze integral behavior of light water nuclear powerplants under severe accident conditions. IMPACT-SAMPSON's distinguishing features include interconnected hierarchical modules and mechanistic models covering a wide spectrum of scenarios ranging from normal operation to severe accident events, and high-speed simulation on parallel processing computers. The integral plant behaviors of typical PWR and BWR under severe accident conditions have been analyzed with the IMPACT-SAMPSON code. The PWR plant analyzed was the three-loop, steel-dry containment type with 2,440 MWt. The AE accident scenario was supposed, that is, LOCA by 6-inch hot leg failure followed by accumulated water injection, but no ECCS and containment spray activation. The BWR plant analyzed was the ...
This report describes selective catalytic reduction (SCR) technologies which offer an economical and effective means of reducing nitrogen oxide emissions from electricity generation facilities and reviews the feasibility and cost effectiveness of employing this technology on electricity generating facilities in Ontario. Based on experiences in the United States, in British Columbia, and internationally in Japan and Germany, the indication is that the technology for the installation of SCR systems on new gas-fired combined cycle powerplants and existing coal-fired powerplants has grown enormously during the past decade, and has been established as the control technology of choice for nitrogen oxide emissions. It is widely acknowledged to reduce powerplant nitrogen oxide emissions, and do so at a very reasonable incremental cost. It is estimated that the ...
Transposon-based integration systems have been widely used for genetic manipulation of invertebrate and plant model systems. In the past decade, these powerful tools have begun to be used in...Full Text Available
In order to maintain a safe operation and availability of generating facilities, qualitative and quantitative assessment of piping vibration was performed vibration sources and damages of piping support was identified on the second piping system of Wolsun...
Limestone slurry needs to move efficiently through a complex process, meaning that selecting the right pumps and valves is critical. The article discusses factors to consider in selecting pumps and values for flue gas desulfurization process in coal-fired powerplants. 2 photos.
This paper documents some of the recent uses of robotics for inspection and maintenance activities in Ontario Hydro's nuclear powerplants in areas other than fuel channels and steam generators. 7 figs.
The guide describes a method acceptable to the NRC staff for complying with the Commission's regulations with regard to quality assurance requirements for installation, inspection, and testing of mechanical equipment and systems for water-cooled and high-temperature gas-cooled nuclear powerplants.
The picture of wind energy parks at the German North Sea Coast is well-known. There are also some of them on the Northern Friesian Islands. Recently, however, biogas plants have been conquering the western coast of Schleswig-Holstein, starting from the continent.
This presentation describes a method for analyzing, quantifying, and minimizing the total cost of fossil, combined cycle, and pumped hydro powerplant cycling operation. The method has been developed, refined, and applied during engineering studies at some 160 units in the United States and 8 units at the Irish Electric Supply Board (ESB) generating system. The basic premise of these studies was that utilities are underestimating the cost of cycling operation. The studies showed that the cost of cycling conventional boiler/turbine fossil powerplants can range from between $2,500 and $500,000 per start-stop cycle. It was found that utilities typically estimate these costs by factors of 3 to 30 below actual costs and, thus, often significantly underestimate their true cycling costs. Knowledge of the actual, or total, cost of cycling will reduce power production costs by enabling ...
During the past decades polymer membrane technology has been applied in various industries for a myriad of separation duties. They are also an important candidate for the solution of separation problems associated with the recovery of carbon dioxide in powerplants. The application of membrane technology for carbon dioxide removal is discussed for two different ways of operation in present and future powerplants. First, pressure driven operations are discussed, followed by a discussion of the use of membranes in absorbers. The pressure driven processes based on currently available gas separation membranes are shown to have poor separation characteristics. Further membrane development work appears to be necessary, especially in the area of temperature resistant membranes. Membrane selectivity goals are presented for present and future powerplants. Membrane ...
The author investigates the question of the maximum capacity of steam turbines in nuclear powerplants when towards the end of the nineties turbo-generator units of 3,000 MW and more will be necessary as a result of increased energy demand. (TK).
Environmental surveys to provide base-line data for assessing the potential impact of the operation of Wolseong NPP on marine ecosystems were performed at 3-month intervals in 1981. Physico-chemical properties of seawater and gross beta activities in seaw...
Investigation of Interaction of Laser Radiation with Radioactive Deposits on the metal Surface and Creation of Experimental Stand for Development of Laser Technology for Remote Treatment of Materials Contaminated with Radioactive Substances at the Atomic PowerPlants
This article examines the effects of competition of geothermal energy production with other technologies. The topics of the article include near-term market growth, cause for cautious optimism, limits to development of geothermal energy production, economic arguments for development of geothermal powerplants, the effects of a competitive market on industry survival.
This is the final Report for the technical ''on-the-job traning'' for the Wolsung CANDU nuclear powerplant which is the first Pressurized Heavy Water Reactor setting up in Korea. The technical ''on-the-job traning'' was established to increase the capabi...
Results of field applications of boric acid in the secondary coolant circuits of seven PWR units for the purpose of reducing the rate of corrosion denting are reported. Based on available data at the powerplants considered in this study, it was not possible to support or refute the benefit of using boric acid secondary water treatment.
To estimate of the dispersion trend of 3H and 14C discharged from the Wolsung Nuclear PowerPlants, the present level of 3H and 14C in environmental samples in the vicinity of the Wolsong site was studied. Tree-ring cellulose analyses were carried out for retrospective evaluation of 3H and 14C in the environment around the Wolsong Nuclear PowerPlants. 3H released from the Wolsong Nuclear PowerPlants has affected an area up to a 25-km radius from the site, while almost all 14C was deposited within a 2-km radius, reaching to a natural level over 2 km. Organically bound tritium concentrations in tree rings were strongly correlated with the gaseous tritium discharge rate, while delta14C (excess) in tree rings ranged from 204 per thousand to 460 per thousand, which did not significantly vary with year. PMID:10832930
Legal aspects of using natural gas as boiler fuel for electric utilities are reviewed through one utility's challenges to the PowerPlant and Industrial Fuel Use implementation. ASARCO vs. FPC, 1973, and City of Willcox vs. FPC are discussed. (PSB)
Liquid Phase Catalytic Exchange (LPCE)- Cryogenic Distillation(CD) process was studied which could be available for an optimal tritium removal process of pressurized heavy water reactor system at Wolsung nuclear powerplant in the near future. Based upon ...
In the study three loss-of-feedwater type experiments which were preformed with the PACTEL facility has been calculated with two computer codes. The purpose of the experiments was to gain information about the behaviour of horizontal steam generator in a ...
In situ hybridization, a powerful tool for the molecular cytogeneticist, can be used to physically map repetitive, low-copy, and unique DNA sequences in plant chromosomes. With the availability of a...Full Text Available
The report describes a computer model developed by TVA to simulate the performance and determine the economics of coal cleaning, or coal cleaning combined with flue gas desulfurization (FGD), for powerplant emission control processes over a wide range of user-specified condition...
On the problem of alarm when parts are falling in nuclear powerplant, the artificial neural network (ANN) alarm method based on the signal time-frequency characteristics was developed. The method was realized by the improved BP algorithm, and demonstrated with the data from simulation experiments
The use of excitation system controls, specifically the Power System Stabilizer (PSS), to improve damping of power system oscillations and thus extend steady-state stability limits has been a subject of great interest in recent years. The desire to more fully utilize transmission capacity led to the installation of PSS controls on greater numbers of generating units to maintain stability margins. This paper addresses the tuning and adjustment of PSS controls in a two unit powerplant. Both analytical studies and field test confirmations are presented. The practical difficulties of verifying the PSS control loop gain margin by testing are explored. A simplified procedure is outlined. The Lower Colorado River Authority (LCRA), Fayette Power Project (FPP) consists of two 683.7 MVA tandem compound steam turbine driven generators. The excitation systems are of the alternator rectifier ...
Within the Annual Conference 2009 of the VGB PowerTech e.V. (Essen, Federal Republic of Germany) from 23rd to 25th May, 2009, in Lyon (France) the following lectures were held: (1) Electricity demand, consequences of the financial and economic crisis - Current overview 2020 for the EU-27 (Hans ten Berge); (2) Status and perspectives of the electricity generation mix in France (Bernard Dupraz); (3) European electricity grid - status and perspective (Dominique Maillard); (4) Technologies and acceptance in the European energy market (Gordon MacKerran); (5) EPR construction in Finland, China, France, (Claude Jaouen); (6) EPR Flamanville 3: A project on the path towards nuclear revival (Jacques Alary); (7) Worldwide nuclear Revival and acceptance (Luc Geraets); (8) An overview on the status of final disposal of radioactive wastes worldwide (Piet Zuidema); (9) Who needs pumped storage plants? PSP are partner to grid stability and renewable energies ...
Within the Annual Conference 2009 of the VGB PowerTech e.V. (Essen, Federal Republic of Germany) from 23rd to 25th May, 2009, in Lyon (France) the following lectures were held: (1) Electricity demand, consequences of the financial and economic crisis - Current overview 2020 for the EU-27 (Hans ten Berge); (2) Status and perspectives of the electricity generation mix in France (Bernard Dupraz); (3) European electricity grid - status and perspective (Dominique Maillard); (4) Technologies and acceptance in the European energy market (Gordon MacKerran); (5) EPR construction in Finland, China, France, (Claude Jaouen); (6) EPR Flamanville 3: A project on the path towards nuclear revival (Jacques Alary); (7) Worldwide nuclear Revival and acceptance (Luc Geraets); (8) An overview on the status of final disposal of radioactive wastes worldwide (Piet Zuidema); (9) Who needs pumped storage plants? PSP are partner to grid stability and renewable energies ...
Nuclear Fuel Plant (FCN) is a facility that produces fuel bundles of CANDU-6 type for the CANDU nuclear powerplant. Only natural and depleted uranium in bulk and itemized form are present as nuclear materials in this facility. Uranium and wastes from the plant are handled, processed, treated and stored throughout the entire facility. The nuclear materials with natural and depleted uranium are entirely under nuclear safeguards. The amount of uranium present in the plant in different forms and activities together with zircaloy, beryllium and other hazardous substances, wastes, explosive materials at high temperatures, etc. lead to special measures undertaken by Nuclear Safety Department (DNS) to ensure nuclear safety. Different aspects of safety are continuously monitored in the plant: operational safety, industrial safety, radiological safety, labour safety, ...
The thesis gives an overview of the validation process for thermal-hydraulic system codes and it presents in more detail the assessment and validation of the French code CATHARE for VVER calculations. Three assessment cases are presented: loop seal clearing, core reflooding and flow in a horizontal steam generator. The experience gained during these assessment and validation calculations has been used to analyze the behavior of the horizontal steam generator and the natural circulation in the geometry of the Loviisa nuclear powerplant. Large part of the work has been performed in cooperation with the CATHARE-team in Grenoble, France. (41 refs., 11 figs., 8 tabs.).
Tritium dose management is an important aspect of the radiation protection program at CANDU type reactor sites. This paper describes the bioassay and dosimetry of tritium at CANDU reactor sites, especially for Wolsung Nuclear PowerPlant. It presents a compilation of information drawn from published papers, technical reports, international and national guidelines as well as practical experience both in Korean and Canadian CANDU Nuclear PowerPlants. The implementation of this program would provide a technical basis for calculations and records should be of acceptable quality and should meet overall radiation protection program objectives.
Pressurized fluidized bed combustion (PFBC) is an emerging coal-fired, combined-cycle power generation technology nearing commercial status through several operating and planned demonstration plants throughout the world. Current-generation PFBC plants use ``ruggedized`` gas turbines that can tolerate dust loading common with conventional cyclone gas cleaning. The next generation of PFBC will apply advanced hot gas cleaning systems that will reuse the dust loading to low levels acceptable to high performance, industrial gas turbines. These advances should result in performance and cost advantages. This article examines the demonstration of PFBC technology at Tidd power station.
The Daya Bay reactor neutrino experiment is located at the Daya Bay nuclear powerplant in Shenzhen, China. The experiment deploys eight 'identical' antineutrino detectors to measure antineutrino fluxes from six 2.9 GWth reactor cores in three underground experimental halls at different distances. The target zone of the Daya Bay detector is filled with 20 t 0.1% Gd doped LAB liquid scintillator. The baseline uncorrelated detector uncertainty is ?0.38% using current experimental techniques. Daya Bay can reach a sensitivity of sin22?13<0.01 with baseline uncertainties after 3 years of data taking.
Axial offset anomaly (AOA) is caused by the deposition of crud on the fuel cladding of a PWR. When significant levels of crud build up on the cladding, boron can accumulate in the pores of the crud as a concentrated solution or solid phase, and cause the flux depression. Numerous studies have been conducted on the primary water chemistry to reduce the amount of crud in the primary circuit to avoid radioactivity buildup and unexpected power transition in the plant. However, experiments on the crud are restricted in the laboratory because the crud is a highly radioactive material. The objective of this study is to develop a test method for simulating the deposition of crud in a nuclear powerplant
This paper presents a rationale for and a summary of tasks and missions to which mobile and stationary robots and other teleoperator-controlled devices could be assigned in response to the accidental release of radioactive and other hazardous/toxic materials to the environment. Many of these vehicles and devices currently support operation and maintenance of nuclear powerplants and other nuclear industry facilities. This paper also discusses specific missions for these devices at the Three Mile Island and Chernobyl nuclear powerplant sites at the time of the accidents. Also discussed is the status of devices under development for future applications, as well as research on robotics.
This paper describes and analyses the new situation in the electricity market in Sweden and the attendant emergence of a unique marketing opportunity for industries and powerplants to capitalize on bioenergy. This recent marketing opportunity, which is based on consumer demand, has come about through a number of recent institutional changes in Sweden that have drastically lowered the transaction costs associated with the purchase of green electricity, i.e. electricity generated in what is classified as an environmentally sound manner. This has created a functioning market for green electricity and products made using green electricity.
Life management system is based on the valid nowadays in Estonian powerplants regulation documentation. The system allows to estimate stress distribution in components, find computational assessment of cumulated creep damage, determine when and where it is necessary to cut off the particular number of microsamples or take replicas. Finally, the real metal condition may be assessed on the basis of metallographic specimen research and reasonable 3-R decision - run, repair, replacement - made on further component use. (orig.) 6 refs.
This paper discusses key methods for sustaining quality engineering data, the fundamental principles that these methods are based on, and the methods for supporting the performance of nuclear powerplants by the provision of quality engineering data at all times. The concept of an 'engineering data foundation', and a Configuration Management data model are developed. The concepts and methods for managing the integrity of engineering data across many different databases and document systems are developed, including the key concepts of data-positions and data-values, Master Data and Copy Data, and the concept of a 'partnership between people and technology'. (author). 7 refs., 1 tab., 2 figs.
This paper introduces the inter-comparison results of some environmental radioactivity monitoring items for Daya Bay nuclear powerplant. The inter-comparison was organized by China Institute for Radiation Protection and five laboratories participated in it. The compared items included total #beta# in kelp and sediment, "3H in water, "9"0Sr in soil, artificial nuclides "1"1"0"mAg, "2"4"1Am, "1"0"9Cd, "5"7Co in kelp and sediment. Inter-comparison results are analyzed as well
Sessions covered economic and management, advance control technologies (including pulverized coal dynamic balancing-activator and control strategy by B. DeMarcy and X.Ollat), nuclear technologies, environmental (including purge considerations for seasonal SCR systems by D.P. Evely, NOx and heat rate supervisory control at NRG-Huntley operations by G Lange, comparison of gypsum dewatering technologies at flue gas desulfurization plants by B.A. Perlmutter, beta gauge particulate monitoring by J.L. Arnold), improving performance at nuclear powerplants, network security, and emerging applications.
This article discusses the Daya Bay nuclear powerplant in-core flux thimble tube in-service inspection method and strategy. High light of the multiple frequency eddy current technology adopted including frequency and probe choice, standard design, data acquisition process are involved. The wear defect-growing trends are studied on base of the history data, which contribute to the in-service inspection strategy decision. (authors)
Five fires that occurred in the air and gas treatment systems of U.S. commercial nuclear powerplants are reviewed. The causes of the fires, the method of extinguishing them and possible fire prevention methods are correlated with the properties of the adsorbents. The similarities and differences of adsorbent (carbon) fires of solvent recovery systems and the nuclear air-cleaning units are discussed in relation to fire development, consequences of the fire, and fire extinguishing methods. The latest methodology of fire prevention, as proposed for a New Hampshire nuclear powerplant is described.
Results are summarized of a study on concrete component aging and its significance relative to continued service of nuclear powerplants (NPPs) beyond the initial period for which they were granted operating licenses. Progress is presented of a second study being conducted to identify and provide acceptance criteria for structural safety issues which the USNRC staff will need to address when applications are submitted for continued service of NPPs. Major activities under this program include: development of a materials property data base, establishment of structural component assessment and repair procedures, and development of a methodology for determination of structural reliability. 19 refs., 5 figs., 3 tabs.
A special study was conducted to investigate the influences of minimum approach temperature differences occurring in supercritical-heater/vaporizer and evaporative-condenser heat rejection systems on geothermal-electric binary powerplant performance and cost of electricity. For the systems investigated optimum pinch points for minimizing cost of electricity were estimated to range from 5 to 7/sup 0/F for the heater vaporizer. The minimum approach of condensing temperature to wet-bulb temperature for evaporative condensers was estimated to be about 30/sup 0/F in order to achieve the lowest cost of electricity.
Higher efficiencies of steam powerplants are achieved by raising the operating temperature and pressure. The use of ferritic steels helps to minimize the cost and enhance the flexibility (two-shift operation, frequent starting and stopping). The COST programme had the long-term goal of developing and testing 9- 12 % Cr steels with high fatigue strength and to produce,test and operate critical components for an advanced steam powerplant (steam temperature 600 C and supercritical pressure). (orig.)
The objective of Configuration Risk Management Program(CRMP) is to maintain the safety level by assuring the defense-in-depth of nuclear powerplant while the configurations are changed during plant operations, especially for the LP/SD. Such a safety purpose can be achieved by establishing the risk monitoring programs with both quantitative and qualitative features. Generally, the quantitative risk evaluation models, i.e., PRA models are used for the risk evaluation during full power operation, and the qualitative risk evaluation models such as safety function assessment trees are used. Through this study, safety function assessment trees were developed.
As a counter measure to protect against global warming, the development of CO{sub 2} recovery technology from fossil fuel powerplant flue gas has continued. MEA processes are widely used for CO{sub 2} recovery from combustion flue gas in average use etc. However, if we consider powerplant scale CO{sub 2} recovery, the biggest theme is the reduction of energy needed to recover CO{sub 2}. The paper focuses on sterically hindered amines and a new absorber packing. Also optimum steam system analysis results are indicated. 1 ref., 16 figs., 3 tabs.
A methodology of tsunami PSA was developed in this study. A tsunami PSA consists of tsunami hazard analysis, tsunami fragility analysis and system analysis. In the case of tsunami hazard analysis, evaluation of tsunami return period is major task. For the evaluation of tsunami return period, numerical analysis and empirical method can be applied. The application of this method was applied to a nuclear powerplant, Ulchin 56 NPP, which is located in the east coast of Korean peninsula. Through this study, whole tsunami PSA working procedure was established and example calculation was performed for one of real nuclear powerplant in Korea
A software called KEPCO RCM workstation (KRCM) has been developed to optimize the maintenance strategies of Korean nuclear powerplants. The program modules of the KRCM were designed in a manner that combines EPRI methodologies and KEPRI analysis technique. The KRCM is being applied to the three pilot system, chemical and volume control system, main steam system, and compressed air system of Yonggwang Units 1 and 2. In addition, the KRCM can be utilized as a tool to meet a part of the requirements of maintenance rule (MR) imposed by U.S. NRC. 3 refs., 4 figs. (Author)
High conductivity liquid waste, which is produced in nuclear powerplants, is now processed with radwaste evaporator. The concentrated liquid waste in the evaporator is so highly radioactive and corrosive that the improvement on maintenability and reduction of exposure dose rate are desirable as well as high decontamination factor (DF). Fuji Electric constructed the improved experimental facility of evaporator and carried out an experiment to demonstrate DF, maintenability and controllability of system. As the results, DF, maintenability and controllability were proved to be excellent and its applicability to nuclear powerplant was well established.
Results are reported from initial characterization tests on the environmental effects of the natural draft cooling tower of the Chalk Point Unit 3 oil-fired powerplant located on the shore of Chesapeake Bay. Data are included on updraft air velocity, plume drift, and sea salt deposition in relation to meteorological conditions.
It is important to accurately estimate the effects of strong earthquake motions on the basemat uplift behavior and structural responses for the seismic design of nuclear powerplant buildings. In this paper, an analysis model which describes the soil part using the 3 dimensional FEM was proposed to be used when the ground contact ratio is low, and the validity of this model was confirmed. Furthermore, investigations using the model were carried out where the attaching force under the basemat was taken into account, in order to more realistically estimate the basemat uplift behavior. The effects in the case of the building being embedded were also investigated.
It is important to accurately estimate the effects of strong earthquake motions on the basemat uplift behavior and structural responses for the seismic design of nuclear powerplant buildings. In this paper, an analysis model which describes the soil part using the 3 dimensional FEM was proposed to be used when the ground contact ratio is low, and the validity of this model was confirmed. Furthermore, investigations using the model were carried out where the attaching force under the basemat was taken into account, in order to more realistically estimate the basemat uplift behavior. The effects in the case of the building being embedded were also investigated.
The author describes the purpose, classification and main process of acceptance test of full scope simulator of Daya Bay Nuclear PowerPlant, including the correction of non-conformance items which are discovered during the performance of acceptance tests. The results of the acceptance tests show that the model accepted by the full scope simulator of Daya Bay Nuclear PowerPlant is fully able to cope with the simulation of normal transients and incidental transients and the performance of the simulator indeed compiled with the technical specifications which are defined n the relevant contracts.
The scope and contents investigate and reviewed are as follows : establishment of study plan and references survey, review of related problems and inservice test standards of safety injection pump in use nuclear powerplant, review of the study results in laboratory, the theoretical investigation of temperature rise according to mini-flow rate of pump, mini-flow rate working characteristics of high and low pressure injection pumps at nuclear powerplants, setup of testing equipment for measuring ampere, discharge pressure and vibration, selection and behaviors analysis of major parameters concerning pump degradation.
In this paper the thermal design of a horizontal steam generator for the Indian PHWR nuclear powerplant is described. The main attraction is absence of tube sheet and use of stainless steel 'U' tubes. It is emphasised that with appropriate water chemistry it is possible to use stainless steel tubes, which is many times cheaper than the Incoloy tubes used elsewhere. The design approach, applicable equation for the design and the results of computation in the form of heat transfer area and some important dimensions of the steam generator are presented.
Since the 1970s, Danish electricity supply has been dependent on imported coal. This has lead to greater reliability of supply, as could be seen during the Gulf War when Danish electricity prices remained stable in contrast to conditions in other countries. The disadvantage is the air pollution caused by coal combustion. This is regulated, it is stated, by several international laws and agreements, and these are named here. The nature of this form of pollution is explained in relation to actual Danish powerplants and their efforts to reduce emissions of sulphur dioxide and nitrogen oxides. Carbon dioxide, which is a greenhouse gas, is also emitted. Danish environmental policy concentrates on these problems. The efforts of the electric power companies to reduce air pollution are detailed, both nationally and internationally, and their positive consequences are described. Desulphurization and denitrification costs are ...
Combined energy plants operating on the Brayton-Rankine cycle have gained wide acceptance as the most efficient energy conversion system. The technology is well proven and numerous research activities are underway to develop it further past its present plateau of performance. In developed and emerging economies alike, the current situation in the global economic market has caused the liberalisation of the energy industry in some countries, and in others it is causing a rethink of economic and energy policies. A result is that electric utility companies that have enjoyed a monopoly in power generation and distribution are seeing this privilege being eroded. This is opening up opportunities for independent power production and, consequently, for gas/steam turbine plants because of the technical merits of the technology and its ability to fill the vacuum being created in the energy industry. An economic ...
It is desired that the data on past ground information are easily picked out and used effectively when construction of power facilities such as powerplants is planned. For this purpose, a data base system that is available for survey planning and design business has been developed. This system is divided into subsystems for input, registration, and output, which all can be processed by the personal computers. It also has a retrieval function for maps such as area maps and power facility maps in addition to a retrieval function for characters. As output functions, the system has a function to extract ground information through maps of facilities and their peripheries, an output function for geological profiles and soil test results, and liquefaction analysis and design constant setting support functions. As instances, applications of this system to the thermal power ...
Quality Assurance (QA) has not been taken very seriously in developing countries despite their having significant nuclear power programmes. This may affect plant reliability and demands that urgent and serious attention be given to the development and implementation of Quality Assurance programmes according to local conditions. Confusion has been created by the differences in definitions and interpretations of terminologies of Quality Assurance and Control. Problems have been aggravated by the lack of clearly defined responsibilities and accountabilities during the projects execution phases of site selection, data collection, design, equipment fabrication and construction, etc. Therefore, reliability of nuclear powerplants in developing countries is relatively low. But whenever some programme of QA has been implemented it has helped to improve the plant performance. This is ...
Norway is privileged with extensive resources of natural gas, oil and hydropower. Location of gas fired combined cycle (CC) powerplants in Norway offers advantages due to the availability of natural gas from the Norwegian continental shelf and fairly low ambient temperatures, giving high fuel-to-electricity conversion efficiency. The continental shelf provides large storage capacity for CO{sub 2} in deep saline aquifers and in drained gas fields. In this paper the results of extensive work on CO{sub 2} capture carried out during the last years by Statoil in co-operation with several engineering contractors, are presented. The goal has been to develop a commercially viable concept for a combined cycle powerplant including CO{sub 2} capture and sequestration. The main concept is based on CO{sub 2} capture from exhaust gas from a combined cycle powerplant, using ...
In order to serve for efficient energy utilization and environmental improvement in the Republic of Vietnam, a 'Model project to reduce electric power consumption at cement burning plant' has been implemented. This paper summarizes the achievements. This project is intended to add an advanced, matured and reliable electric power generation facility using cement waste heat to the existing cement plant in Vietnam to produce steam and generate power by utilizing the waste heat generated from the preheating process in the burning plant. The present project has performed the detailed designing on the piping, electric facilities and instrumentation based on the basic agreement on the project. Fabrication of the piping has been executed by the Vietnam side. Valves and electric devices were procured and transported, including those fabricated in the ...
In order to meet the needs of remote servicing performed in nuclear powerplants, in fuel reprocessing plants and in atomic research centers three companies: - STMI, subsidiary of CEA, EDF and SGN, specialized in decontamination and dismantling, - La Calhene, subsidiary of CEA and SGN, specialized in robotics, - Inspectronic, manufacturer of closed circuit television cameras, have combined to create the Visionic Society, the main objectives of which are observation by television and inspections in radioactive environment.
The main steam piping of nuclear powerplant which runs between steam generator and high pressure turbine has been experienced to have a severe effect on the safe operation of the plant due to the vibration induced by the steam flowing inside the piping. ...
Design considerations are given for the secondary side region of a vertical U-tube nuclear stream generator with an integral preheater. The thermal shield design, the novel recirculating water flow distribution scheme, the high porosity tube supports used in the parallel flow regions, and the U-bend supports are discussed for the Wolsung Plant steam generators. Experimental and analytical development programs undertaken to verify the design features are outlined.
As a result of the accident at the Chernobyl PowerPlant the larger part of Belarus turned out to be polluted by radionuclides. At present isotopes of Cs, Sr and Pu, characterized by long half-lives are most dangerous for the health of the population of the polluted territories. The aim of the present work was to characterize plant species with high "1"3"7Cs and "9"0Sr accumulation ability and to determine the dependence of the accumulation on the treatment with biologically active substances. (author)
Pumping is one of the means for storing vast quantities of energy. This article analyses its principles and ways of implementation with emphasis on its double aspect, e.g., on the one hand, off-peak power is transferred to the periods of heaviest load and is thus valorized, even when taking into account losses due to poor efficiency of operations in the pumping and turbine modes, and on the other hand, plants have great flexibility in operation, faciliting the permanent fitting of generation to demand.
The systems analyses and optimization studies performed in connection with a program to design and evaluate a commercial 663 MWe coal-fired combined cycle powerplant using pressurized fluidized bed combustion and advanced technology in the hot gas cleanup system and gas turbines are presented. Details on the plant control system are included. (LCL)
The invention deals with a pumping plant for oil filled power cables. An air driven piston type pump is used as primary pump. A PLS (Programmable Logic control System) is used to control the oil flow to the cable(s). Improvements of the pump includes means for ensuring that the pump piston is operated also at low pressure and flow, and means for sealing off the piston rod to ensure maximum life of seals, to facilitate detection of possible leakages and to avoid contamination of the cable oil. 3 figs.
This paper outlines the development of an organizational model which will be used to determine the influence of supervisory and management functions in a nuclear powerplant (NPP) on risk. A theoretical conceptualization, derived from the empirical literature, is used to describe the organizational structure of NPPs. The parameters and variables associated with this dynamic, process-oriented model are detailed. Applications of the model and preliminary insights derived from this conceptualization are discussed.
The management procedure of a large PRISE (Primary-to-Secondary) leakage accident at Loviisa nuclear powerplant taking into account the plant modifications which are expected to be realized during 1995-96 is described. The management procedure has been validated by performing thermal hydraulic analyses with the computer code RELAP5/MOD3 and the results from these analyses are also shortly discussed. (4 refs., 6 figs., 1 tab.).
A krypton recovery pilot plant has been completed for the Power Reactor and Nuclear Fuel Development Corporation. This is the first industrial facility in the world to make practical use of development results for offgas treatment and storage from nuclear facilities. The cryogenic distillation process was adopted as a proven and reliable method to separate krypton and xenon, and to reduce gas effuents to a level so low that the decontamination factor amounts to more than 1000.
The results of the development work to improve the horizontal steam generator modelling using the CATHARE code as well as the results of the steady-state and the steam-line break calculations are presented. Also the results of the steady-state calculations are compared to the measurements performed in operating VVER powerplants. (9 refs., 6 figs., 2 tabs.).
The results of the development work to improve the horizontal steam generator modelling using the CATHARE code as well as the results of the steady-state and the steam-line break calculations are presented. Also the results of the steady-state calculations are compared to the measurements performed in operating VVER powerplants. (9 refs., 6 figs., 2 tabs.).
Due to the intensity and vast number of subjects, this Bremen experts' discussion, too, could discuss only part of the problem of the possibilitiy to quantify the radiation hazard. One preliminary result is that there is no scientific proof of the harmlessness of radiation exposure during normal operation of a nuclear powerplant, either within the plant or in its vicinity. Other results are that some important questions can not be answered yet, and that there are important hints on the dangers even of low radiation doses. (GL).
The intention of the research carried out was to develop photovoltaic driven solar heating systems applied for drying of medicinal plants in remote areas. Identification of hybrid photovoltaic - photothermal systems was done and discussion of technical features and applicability of such systems in agriculture is presented. Detail technical specification of PV powered medicinal plants solar dryer and cost effectiveness parameters are given. Operational and economic results obtained during testing of the dryer are promising. (orig.) 4 refs.
The present code requirements on quality assurance as well as the present praxice of quality assurance procedures in the operation of nuclear powerplants are presented. On the example of recurring inspections the organizational and technical complications are shown with respect to the code and licensing requirements. Taking the present experiences into account suggestions are given how to transform the general requirements of KTA 1401 to quality assurance requirements during plant operation. (orig.).
The conditions for the production of activated charcoal having a decolorization power (DP) of less than 160 mL/g for methylene blue solutions from the wood of rubber plants were activation temperature of 1000 degrees, rentention time of 30 minutes, and steam-char-ratio of approximately 1.7. The installation of a side-burner around the rotary kiln to decrease the temperature gradient increased the DP of the activated charcoal to 190-200 mL/g without a decrease in yield.
TVA is currently engaged in an extensive program to mitigate steam generator tube denting at the Sequoyah Nuclear Plant, which is in commercial operation, and to prevent or minimize the onset of denting at the Watts Bar Nuclear Plant, which is under construction. This paper describes TVA's denting mitigation program, which is primarily feedwater chemistry and system operation improvement, and the effect the changes that have been implemented have had on the incidence as well as the progression rate of steam generator tube denting during the past 220 effective full power days of Sequoyah unit 1 operation.
Recent research work on adjustable speed pumped storage plants conducted in Japan, the USA and Europe suggests that they have many advantages over fixed-speed plants, and can contribute to power system regulation even in pump mode. This paper describes two types of static frequency converter for such pumped storage plants, especially those with greatly fluctuating heads. The design characteristics and operation of the doubly fed induction machine and the synchronous machine with DC link converter are set out and the devices compared. (UK)
A self contained continuous power generation system as described at INTELEC 1979, was successfully commissioned and put into service in a major communications centre at Cardiff in Wales. The objective was to provide all telecommunications equipment and electrical building engineering services from a dual fuel enginegenerating plant, and to recover waste heat energy to heat or cool the building. The plant, which is fully automatic, comprises five 1300kW engines using natural gas or diesel oil, and associated waste heat boiler and chiller systems. This paper reviews the functioning of the plant during its first three years of operation.
The general types of pumped-storage plants and considerations for determining their need, use, and selection are presented. A brief discussion of TVA's experience on two pumped-storage schemes is included. Pumped-storage plants have become an integral part of many hydropower systems. Most of these systems use pumped-storage plants to meet power requirements during the peak load demands. In any application, large or small, the expected load demand and supply source must be identified to select the best scheme required for the particular system.
A generalised procedure for quantifying the benefits of household biogas plants is presented. The sensitivity of the procedure to the uncertainty in input prices is reduced through the assumption of incremental benefits from the biogas plant. These benefits are quantified in terms of the quantity of fuelwood for which the biogas substitutes in cooking, the quantity of kerosene replaced through the use of biogas for lighting and the diesel fuel displaced through the use of a biogas fuelled dual-fuel engine for motive power. Sensitivity of the monetary benefits for these parameters is examined in order to identify variables which influence the viability of the technology to the end user. (author).
To ensure safe and reliable power production nuclear powerplants must be operated at high level. Non destructive in-service inspections are inseparable part of the effort. Non destructive in-service inspections are essential on the ground of degradation mechanisms existence in nuclear power components. Degradation processes are constituent of operation of each industrial installation including nuclear powerplants. Mission of non-destructive testing is degradation detection, closer characterization of its parameters (dimensions) and to supply as much information as possible to nuclear powerplant operator. Eddy current testing method can be assigned to surface - volumetric methods. Method enables inspection of electrically conductive materials. It is particularly suitable for inspection of non-ferromagnetic materials ...
The paper discusses the potential environmental impacts associated with the operation of a large, say 350 MWe, gas-fired combined cycle power station. It concludes that if appropriate control methods are introduced at the design stage of the plant, environmental impacts are minimal and can be considered acceptable. (author).
Pumped storage plants (PSP) supply up to several GW of power and several ten GWh of capacity. Short start-up times and low start-up costs predestine PSP for the control energy market. Grid charges for PSP endanger the further integration of renewable energy and lead to higher electricity supply costs. Therefore, an amendment of legislation is urgently required. Requirements for building large PSP are met at numerous sites in the low mountain ranges of Germany. (orig.)
These proceedings compile the papers presented at the international conference (1988) sponsored by IEEE Council on ''Robotics and Automation''. The subjects discussed were: automation and robots of nuclear power stations; algorithms of multiprocessors; parallel processing and computer architecture; and U.S. DOE research programs on nuclear powerplants.
This paper reviews power fluidics technology in the nuclear industry giving emphasis also on its potential uses in chemical plants and in flood and irrigation control. This is a technology of controlling process fluids by purely hydrodynamic methods, which should increase system reliability by eliminating valves, pumps and other fluid control devices that are often causes of failure. This review indicates that the hydrodynamics of fluidic components are not satisfactorily understood at present and may be more complex than similar theory in electronics.
This paper introduces an occupational exposure information system in detail, which is developed and in operation presently by Daya Bay nuclear powerplant. It is presented in the paper that individual dose monitoring items and method, design and classification of database configuration, statistics and analysis of individual dose, and management of staff entering and exiting controlled area. The system is instructive to analysing individual dose and optimizing radiation protection measures. (authors)
In the year 2008, the high pressure partial turbine and two low pressure partial turbines in the hard coal power station Bergkamen (Federal Republic of Germany) were modernized. A three-dimensional blade design and innovative seals were used. This resulted into a distinct increase in efficiency among other things.
This heat exchanger is a critical step in the development of the Externally Fired Combined Cycle power system, a direct-coal combustion powerplant (gas turbine). SiC is the only material with the needed resistance to creep, thermal shock, and oxidation; however a protective coating is needed. Ten candidate materials were identified: alumina-based materials, materials stable with SiO, and low expansion materials. An initial screening study should be performed.
18-Months cycle reload design verifications of Daya Bay NPS is briefly described. It was attempted giving the description of analysis scope and key technology for a nuclear powerplant which will be changed fuel management strategy from one year to 18-months cycle
Water chemistry of nuclear powerplants has played an important role in reduction of personnel doses, structural materials and fuel integrity assurance, and reduction of radioactive wastes production. Further contributions are requested for advanced utilization of the LWR, advanced fuels and aging management of plants. Since water chemistry has an effect on all structure and materials immersed and at the same time affected by them, the optimum control not sticking to specific issues and covering the whole plant is required for these requests. Taking account of roles and activities of the industry, governmental institutes and academia, road maps on research and development plans for water chemistry were compiled into identified eleven items with targets and counter measures taken, such as common basic technologies, dose reduction, SCC mitigation, fuel cans corrosion/hydrogen absorption mitigation, ...
This report presents a view of and commentary on the current status of equipment qualification (EQ) in nuclear industries of the major western nations. The introductory chapters discuss the concepts of EQ, the elements of EQ process and highlight some of the key issues in EQ. A brief review of industry practices and some of the prevalent industrial standards is presented, followed by an overview of current regulatory positions in the USA, France, Germany and Sweden. A summary and commentary on the latest research findings on issues relating to accident simulation, to aging simulation and some special topics related to EQ, has been contributed by Franklin Research Centre of Philadelphia. The last part of the report deals with equipment qualification in Canada and gives recommendations on EQ for new plants as well as currently operational CANDU nuclear powerplants.
KEPCO (Korean Electric Power Corp.) with the support of AECL and other Korean and Canadian subcontractors has created a strong multi-company team to execute design and construction of the Wolsung-2 CANDU 6 powerplant. Key concepts of the project team are: 1. KEPCO is the project manager, and AECL is the major engineering and supply contractor; 2. Significant participation by Korean companies in design work in Canada and Korea; 3. Significant manufacturing in both Canada and Korea; 4. Construction by Korean contractors. Key concepts of the Wolsung 2 design are: 1. Evolutionary improvement of the Wolsung-1 plant which balances proven technology and necessary design improvements including current codes and standards. 2. Sharing some structures with the Wolsung-1 plant. This paper describes the successful establishment and operation of the complex project interfaces along with the ...
A 1 MWe powerplant using waste wood fuel is to be installed at a US Marine Corps base, which will supply all wood from a landfill site. The core energy conversion technology is a down-draft gasifier supplying approximately 150 Btu/scf gas to both spark ignition and diesel dual-fuel engine-generator sets. Features of the plant design include: (1) grinding wood fuel from a wide range of waste resources, (2) specialized screening for fines removal, (3) complete tar and other waste product control without landfill disposal, and (4) use of process heat for bulk fuel drying, gasifier air pre-heating, and wastewater evaporation.
An availability assessment of the principal systems of the Heber Geothermal PowerPlant has been carried out based on the final issue of the process descriptions, process flow diagrams, and the approved for design P and IDs prepared by Fluor Power Services, Inc. (FPS). The principal systems are those which contribute most to plant unavailability. The plant equivalent availability, considering forced and deferred corrective maintenance outages, was computed using a 91 state Markov model to represent the 29 principal system failure configurations and their significant combinations. The failure configurations and associated failure and repair rates were defined from system/subsystem availability assessments that were conducted using the availability assessments based on the EPRI GO methodology and availability block diagram models. The availability and unavailability ranking of the ...
Sizewell B is Nuclear Electric's latest power station, and the Pressurised Water Reactor (PWR) design on which it is based represents a ''first'' for the UK. One of the integral components of the plant is the heating, ventilation and air-conditioning (HVAC) system, which performs a contamination control and gaseous waste management function for the site. During the commissioning of Sizewell B Power Station the extract systems of the HVAC plant underwent a procedure known as ''fingerprinting''. This entailed the characterisation of the facilities provided to test the filtration plant during its lifetime. The assessment of their adequacy was then used to identify necessary modifications and/or to propose the manner in which future in situ performance testing would be carried out. The paper outlines the basic principles and procedure that was used to ''fingerprint'' test systems during ...
This paper presents a new method and newly developed stabilizing equipment to prevent the loss of synchronism of generators in pumped-storage plants from spreading. The proposed method includes functions to estimate the swing of each generator by using on-line generator output sampled at a rate of 600 times per second after an occurrence of disturbance such as fault, faulty equipment and so on, to predict generator swing 200-300 milliseconds ahead and loss of synchronism between generators in pumped-storage plants and those in thermal and nuclear plants, and to decide the number of generators that must be shed to maintain stability. Tokyo Electric Power Co. (TEPCO) installed the newly developed stabilizing equipment based on this method in the power system in June, 1986.
This paper presents a new method and newly developed stabilizing equipment to prevent the loss of synchronism of generators in pumped-storage plants from spreading. The proposed method includes functions to estimate the swing of each generator by using on-line generator output sampled at a rate of 600 times per second after an occurrence of disturbance such as fault, faulty equipment and so on, to predict generator swing 200-300 milliseconds ahead and loss of synchronism between generators in pumped-storage plants and those in thermal and nuclear plants, and to decide the number of generators that must be shed to maintain stability. Tokyo Electric Power Co. (TEPCO) installed the newly developed stabilizing equipment based on this method in the power system in June, 1986.
An important growth in the power of the photovoltaic systems connected to a grid has recently been observed. In spite of the advances in module technology, the problems in the system design increased, especially regarding the surface of the earth they occupy. In this work we propose a complete model for plant simulation with different wiring diagrams and under dynamic shading. Results obtained from simulations showed that the configuration with the lowest performance was that of only one serial-parallel group, whereas the highest efficiency corresponded to a design of groups of modules in parallel connected then in series. In general, a higher efficiency was obtained diminishing the quantity of modules in series and increasing their number in parallel. The simulation model proposed allows exploring different alternatives of wiring modules and finding the most efficient configurations for photovoltaic plants of medium and ...
Explosives have rarely been used in decommissioning of nuclear reactors. Nevertheless, controlled blasting can be used advantageously during careful destruction of nuclear powerplants for removal of concrete, pipe systems, and other components. Experiments performed within a former nuclear powerplant demonstrate the feasibility of this method, employing explosive masses up to 15 kg per blast. The loadings of the components and the total plant structure were measured and compared with code predictions. The experiments show a response of the containment predominantly in frequency ranges above 100 Hz, thus keeping the building and components below German regulation limits for shock excitation. The blast wave pressures are reduced drastically within short distances in the building. Dust and debris can be contained with simple methods such as curtains. Use of this method seems to be ...
IHI has developed a new Three-Dimensional Computer-Aided Design (3D-CAD) system to improve the design efficiency and quality of the steel structure of nuclear powerplants. This system covers every design phase from the initial arrangement of structure to the production design sharing the same database. The system incorporates the design rules and professional expertise of designers, and enable easy and efficient design. The system can easily generate the three-dimensional data for structures, model data for stress analyses and composite arrangement data. The system has already been applied to several plants under construction and has achieved excellent results. The outline of the new CAD system is introduced. (author)
Trace elements were extracted from a coal-fired powerplant electrostatic precipitator ash with nitric acid, hydrochloric acid, citric acid, redistilled water, and ammonium hydroxide as extractants. Effluent waters at this plant were sampled to assess the elevation of trace element concentrations compared with intake waters. The results showed a positive correlation between those elements most extractable by water (B, F, Mo, and Se) or acid (As, B, Cd, F, Mo, and Se) and those elements most elevated in effluent waters (As, B, F, Mo, and Se).
The go ahead for setting up the Smart Grid has been given - on the consumer side, for example, in the form of intelligent electricity meters (Smart Meter). It will be some years, however, before a comprehensive and integrated generation, transport and consumer concept can be implemented. An integral part of this implementation concept will be intelligent energy systems that coordinate individual local power grids and thus ensure optimum exploitation of the power generated. But even without full grid networking energy management can be shaped more intelligently - for example by combining and optimising the power generation capacities of several powerplant locations and energy carriers. (orig.)
Among KEPCO's 9 nuclear power units, Korea Nuclear Unit No. 3, the Wolsung Nuclear PowerPlant is the only CANDU-PHWR Unit, while the rest of 8 others are PWR units. The unit was designed by Atomic Energy of Canada, Ltd. of Canada, who also performed overall project management for the plant construction under the provisions and arrangement of the relevant contracts. The gross electrical output of the plant is 678.7 MWe and thermal output of the reactor is 2061 MWth. While these figures lead to lower plant efficiency than LWR counterparts, unit energy cost for fuel is more favorable than LWRs because natural uranium is utilized for the fuel bundles, some of which are already being fabricated domestically. Annual capacity factors for 1983 and 1984 could have been improved, if two major planned outages for the modification works on steam generator ...
Soil electrical resistivity is perhaps the only soil parameter that is used by geologists and geotechnical engineers to explore the subsurface characteristics at a powerplant site and also used by civil and electrical engineers as input to their design. A properly designed and executed field electrical resistivity survey is one method of examining the subsurface profile. The same program can provide information about the corrosion potential of the soil that can play a major role in determining the protection needed for buried steel piping and pile foundations. At the same time, the soil conductivity interpreted from the results of the resistivity testing is an integral part of the design of the electrical grounding system for the plant. This paper describes soil electrical resistivity, test procedures to estimate resistivity values, and how these values can best be used to obtain the parameters required for successful ...
The purpose of organization and management development activities in the commercial nuclear power industry is to foster high levels of powerplant performance and safety through improved human performance. The NRC has been working to develop assessment tools to assay the effects of organizational factors on plant safety. The utility industry has been working on initiatives targeting individual accountability, the improvement of plant performance and the elimination of the items identified through the NRC assessment process. Organization and management activities do not focus on industry organizational charts, but on the personnel processes and dimensions (factors) that affect safety and economic performance. As individual terms these activities are often combined and referred to as organizational factors. As an area of study, organizational factors has become more prominent as the ...
A quantitative energy pathway comparison is made between a modern oil refinery and genetic fusion hydrogen plant supporting hybrid-electric cars powered by gasoline and hydrogen-optimized internal combustion engines, respectively, both meeting President Clinton's goal for advanced car goal of 80 mpg gasoline equivalent. The comparison shows that a fusion electric plant producing hydrogen by water electrolysis at 80% efficiency must have an electric capacity of 10 GWe to support as many hydrogen-powered hybrid cars as one modern 200,000 bbl/day-capacity oil refinery could support in gasoline-powered hybrid cars. A 10 GWe fusion electric plant capital cost is limited to 12.5 B$ to produce electricity at 2.3 cents/kWehr, and hydrogen production by electrolysis at 8 $/GJ, for equal consumer fuel cost per passenger mile as in the oil-gasoline-hybrid pathway.
Human resource competence building and continued enhancement of performance is the most vital input for safe and reliable operations of a Nuclear PowerPlant. Integrated planning leading to the decision of timely selection of optimum number of fresh people and deployment of experienced manpower with desired lead time is inevitable to achieve the above objective. For safe and reliable plant operation human performance analysis followed by suggestive measures to improve the same is needed. Corrective or strengthening input may be in terms of training, work environment, motivations, organizational culture and climate, leadership and prevailing environmental force and bio-rhythm of individuals with critical days are to be worked out The adequacy in training and development not only gives safe and reliable plant operations but results in greater employee satisfaction and self esteem as well. As of date, in ...
To estimate the waste management needs of a fusion power reactor, a scheme for handling radioactive waste from a fusion plant has been devised. The handling scheme proceeds with radioactive waste, primarily from blanket replacement, being stored on-site; waste in cooled and shielded casks is then isolated off-site; finally, the materials are recycled. Using activities and component lifetimes supplied by designers, several conceptual fusion power reactors have been analyzed and their waste streams compared to fission reactors with regard to total activity, specific activity, and lifetimes of activity.
To estimate the waste management needs of a fusion power reactor, a scheme for handling radioactive waste from a fusion plant has been devised. The handling scheme proceeds with radioactive waste, primarily from blanket replacement, being stored on-site; waste in cooled and shielded casks is then isolated off-site; finally, the materials are recycled. Using activities and component lifetimes supplied by designers, several conceptual fusion power reactors have been analyzed and their waste streams compared to fission reactors with regard to total activity, specific activity, and lifetimes of activity.
Describes the wastes produced and the waste disposal methods used at BEWAG powerplants. Wastes covered include fly ash, fluidized bed ash, gypsum from flue gas desulfurization and evaporation residues. Disposal methods include using ashes and gypsum to make building materials. Despite many years of experience in the utilization and disposal of residues from coal-fired power stations BEWAG have not encountered any disposal problems. 5 tabs.
The theme of the conference was 'The paradox: today's coal technologies versus tomorrow's promise'. The sessions covered: today's technologies, tomorrow's potential; economic stability; energy security; transition to sustainable energy future; new coal power technologies leading to zero emission coal; existing powerplants - improved performance through use of new technology; and carbon capture and storage R & D - challenges and opportunities. Some of the papers only consist of the viewgraphs/overheads.
During the normal operation of a Nuclear PowerPlant (NPP), radioactive releases into the atmosphere will be in small quantities. During major accidental situations, though the probability is extremely small, there may be significant release of radioactivity to the environment through the stack or at ground level. To study the external radiation exposure, if any, to the members of public due to releases during the normal operation of a nuclear powerplant (NPP) and also to meet the requirement of emergency preparedness for the NPP site, continuous recording and analysis of environmental dose rate data is essential. This paper presents analysis of the gamma dose rates recorded by the Environmental Dose Logging Systems (EDLS) installed around the site during the last six years in the Emergency Planning Zone (EPZ) of Tarapur Atomic Power Station (TAPS). (author)
The Heat Cycle Research Program, which is conducted for the Department of Energy, has as its objective the development of the technology for effecting the improved utilization of moderate temperature geothermal resources. The current testing involves the investigation of the performance of binary power cycles utilizing mixtures of non-adjacent hydrocarbons as the working fluids, with supercritical vaporization and in-tube condensation. The utilization of these concepts will improve the net geofluid effectiveness (net plant output per unit mass of geofluid) about 20% over that of a conventional binary powerplant. The major prerequisite for this improvement is the achievement of integral, countercurrent condensation. Results are presented for testing of the performance of the condenser at different tube inclinations. The performance in the vertical orientation is better than in either the horizontal or ...
Weld metal, base material and stainless steel overlay specimens for Charpy tests and static tensile tests were irradiated for a year in a power reactor of the Bohunice nuclear powerplant in place of the evaluated surveillance specimens. The material of the specimens was identical with that of the WWER-440 reactor pressure vessels, and was exposed to a fluence of (1.2 - 4.5) x 10"2"3 m"-"2 (E > 0.5 MeV) at approximately 270 degC. Some of the irradiated as well as unirradiated specimens were subjected to regeneration annealing at 475 degC for 168 h. The behavior of the materials after irradiation and annealing was evaluated. (author). 33 tabs., 32 figs., 8 refs.
The rational use of energy has become a priority for all industries in Brazil, mainly after the energy rationing in 2001. Methodologies to quantify and improve the performance of plants that consume and generate electricity and thermal energy are being used to reach this goal. Exergoeconomic analysis provides a complete diagnosis of a plant, both in exergetic and in monetary values. This study shows the methodology used to assess the power generation system of the Companhia Siderurgica Tubarao (CST). The current system is based on a regenerative Rankine cycle using two gases from steel production - blast furnace gas (BFG) and coke oven gas (COG) - to generate electric power and occasionally steam for the process. Use of the Theory of Exergetic Cost allowed determination of monetary and exe...
The paper discusses a number of recent studies investigating into the energy conservation and environmental impacts of electric heating systems (off-peak storage systems). In future, i.e. in and after 1993, off-peak storage systems will be evaluated through comparative analyses of oil-fired heating systems, pollutant emission analyses, the eventual success of pollution abatement measures designed for powerplant emissions to keep within the legal limiting values, and the possible abandonment of pollution abatement measures abroad. Opposing the electric heating studies submitted by the electric power industry the author refutes their favourable results referring to the palliative selection of inadequate or vague parameters. Assuming average powerplant pollutant emissions of 180 mg/standard/sup 3/ the nitrogen oxide emissions of oil-fired heating systems (134.1 kg/Tj) are found to be ...
Internationally, on-line maintenance (OLM) of nuclear powerplants under the operation is prevailed to enhance nuclear safety and economics. In recent years, Korea Hydro and Nuclear Power Co. Ltd. (KHNP) is eager to apply OLM. Ministry of Education, Science and Technology (MEST) has established the related technology development program as an item of 'Overall Planning on Nuclear Safety(2010-2014)' through acceptance to the request of KHNP in 2009. OLM is defined as maintenance that is performed with the main generator connected to the grid. In other words, it means a preventive maintenance to be implemented during the allowable outage time (AOT) with ignoring inoperability of safety-related equipment listed in the technical specifications. The Korea Institute of Nuclear Safety (KINS) is developing the assessment technology of safety concerns for OLM under the auspices of MEST. Draft regulatory rule-making for OLM is devised ...
The goals of the program include predicting the impact of proposed new generating facilities, evaluating proposed high voltage transmission lines, assessing the impact of existing generating facilities, forecasting future demand for electric power, and investigating numerous information gaps through a long-range research program. The PowerPlant Assessment Division (PPAD) is responsible for all PSC licensing support, site specific research, and radiological monitoring. The list of reports summarizes information of over 190 technical publications that represent the Program`s formalized research and monitoring efforts over the last five years. Reports are listed in chronological order by topical heading.
Variations in thermal energy costs of single module solar central receiver systems using one, two, three, and four aperture cavity receivers at a location corresponding to Barstow, California are investigated for nominal power ratings ranging from 100 MWt to 900 MWt. Also considered are the effects on energy costs of changes in plant latitude, and the energy cost impact of the replacement of the single module design with multiple connected modules producing the same thermal power. The results, obtained with the aid of the DELSOL2 computer program, indicate that solar central receiver plant energy costs are insensitive functions of power level, latitude, and configuration. No clear cost of energy advantage between single and multiple modules is seen.
Generated annually from the Edison Electric Institute's POWER STATISTICS Data Base, the EEI Power Directory provides state-by-state data on all utility-owned steam-electric plants in the US. The 1988 directory contains the following information for approximately 2500 units located at 1000 generating sites around the country: unit age, capacity, fuel type, and operating status. In addition, solid waste disposal methods for fly ash, bottom ash, and sludge are covered for approximately 1500 US coal-fired units. The directory contains a listing of more than 800 environmental managers and key environmental staff at over 300 utilities, with names, addresses, and telephone numbers. Special indices list plants and utility owner-operators.
The hydro-generators suffer during its operative useful life a combination of stresses of nature thermal, electric, mechanics and environmental. With the time, they are going losing the capacity to support those stresses and the powerplants suffer, more and more frequently, undesirable stops for repair services and maintenance. In function of the high costs incurred with these stopped, the operation of the powerplant can be economically impracticable. That unavailability of the generation for the electric system, it results in reduction of the reliability, burdening the politics of load ruling. The re-potentiation is a proposal that seeks to extend the useful life of hydro-generators, at the same time that it try to rescue the reliability and the readiness of the plant, with larger power. The power increase is usually made possible, or for ...
In 1970, the Federal Power Commission predicted a fall from 46% to 27% in 1990 as a result of predicted increases in the use of nuclear power. Today, the Department of Energy expects coal to supply about 50% of electricity generation in 1990. About one-eighth of the world's annual hard coal production is used to make electricity in the United States. Power stations in the country used more coal in 1979 than was produced in the whole Western Europe that year. These 405,000,000 tons of coal equivalent were burned in 1257 individual utilities with an aggregate capacity of 235,000 megawatts. There are coal-fired powerplants in 43 of the 50 states. Four factors will be most important in shaping the future development of coal-based electricity: prices, conservation, environmental regulations, and national security. The price differential between coal and oil has now reached a ...
The purpose of this research is to clarify how psychological factor's impact on public acceptance of nuclear energy varies with people's degree of knowledge. For this purpose, we carried out questionnaire survey about nuclear energy at Suginami ward, Tokyo. After collecting data, we applied factor analysis to the data, and found 4 factors: Trust in the Authorities, Superiority of Nuclear Power Generation, Benefit for Nuclear PowerPlants' Siting Areas, and Risk Perception about Nuclear Technology. In addition, using multiple regression analysis, we evaluated the impact of the 4 factors on 2 issues: the decision for or against nuclear policy and the reaction to nuclear powerplant siting. Consequently, we found the change of impact of all 4 factors on the 2 issues. Especially, the impact of the 4 factors to the reaction to nuclear power ...
The purpose of this research is to clarify how psychological factor's impact on public acceptance of nuclear energy varies with people's degree of knowledge. For this purpose, we carried out questionnaire survey about nuclear energy at Suginami ward, Tokyo. After collecting data, we applied factor analysis to the data, and found 4 factors: Trust in the Authorities, Superiority of Nuclear Power Generation, Benefit for Nuclear PowerPlants' Siting Areas, and Risk Perception about Nuclear Technology. In addition, using multiple regression analysis, we evaluated the impact of the 4 factors on 2 issues: the decision for or against nuclear policy and the reaction to nuclear powerplant siting. Consequently, we found the change of impact of all 4 factors on the 2 issues. Especially, the impact of the 4 factors to the reaction to nuclear powerplant ...
The increasing price differential between natural gas and coal will create a demand for technology that can allow the displacement of natural gas with coal in powerplants. Coal gasification is the standard approach suggested to allow coal to displace natural gas. However, the relatively high capital investment required for coal gasification will require fuel cost differentials higher than those anticipated in the near term before coal gasification replaces natural gas. One way of achieving shorter term displacement of natural gas by coal would be to develop technology that would allow coal to be used as the heat source for the endothermic reforming of natural gas. In a natural gas-fired combined cycle powerplant, the endothermic heat of reforming, which would be provided by coal combustion, is recovered in the combined-cycle. Therefore, this portion of the coal`s energy would be converted to ...
The aim of this case study is to analyse the socio-economic effects of forest fuel supply and use chains. Two of the four cases are rural district heating plants. In Perho, the co-operative organisation of forest owners maintains the fuel supply and operates the plant. In Ruukki, the local forestry association supplies forest chips to the plant. These medium-scale plants use small-sized trees from young thinning stands as their main fuel. The trees are felled manually. The other two cases are large powerplants. Alholmens Kraft's new powerplant in Pietarsaari aim to use 250 000 solid-m3 of forest chips annually. The logging residues are hauled to the plant as bales using traditional timber harvesting equipment or as bulk material. At young thinning stands the trees are harvested using an ...
Two major developments have given impetus to wider adoption of variable-speed turbine/generators in hydroelectric plants, both essentially environmental: (1) the need for stream-bed stability below river dams, and (2) the need to minimize fish damage. Also, the need to stabilize pumped-storage and generating efficiencies to match extreme changes in head levels has been a driving force. Variable-speed operation in hydro applications is relatively new to North America. In other parts of the world, it has been used in pumped-storage plants since 1971. In the US, and increasing potential exists for variable-speed hydro, considering the 30 pumped-storage plants already in operation and several river plants struggling with high head fluctuations--including four at stations operated by the Bonneville Power Administration. Several modifications to hydro-plant hardware ...
The possibility of a positive agricultural use of flue gas filter ash from brown coal powerplants is investigated. The suggested measure is mixing ash dump surfaces with extremely acidic spoil bank soils, which balances the high pH value of the alkaline ash and contributes to improved nutrient and soil sorptive conditions. Optimum quantity of spoil bank sands in the mixture with ash is between 10% and 40%. The optimum quantity must be determined for each type of ash considering improvement of soil chemical conditions and water retention capacity. Filter ash properties vary widely; the required amount of spoil bank sand added to investigated ash surfaces near 3 brown coal powerplants was between 25% and 30% of the mixture. The same favourable soil and ash mixture can be produced by adding 60% to 75% filter ash to acidic raw spoil bank soil surfaces forming a top soil layer in a thickness of minimum 60 ...
A life cycle assessment was performed to quantify the non-renewable (fossil) energy use and global warming potential (GWP) in electricity generation from a typical gas fired combined cycle powerplant in Singapore. The cost of electricity generation was estimated using a life cycle cost analysis (LCCA) tool. The life cycle assessment (LCA) of a 367.5 MW gas fired combined cycle powerplant operating in Singapore revealed that hidden processes consume about 8% additional energy in addition to the fuel embedded energy, and the hidden GWP is about 18%. The natural gas consumed during the operational phase accounted for 82% of the life cycle cost of electricity generation. An empirical relation between plant efficiency and life cycle energy use and GWP in addition to a scenario for electricity cost with varying gas prices and plant efficiency have been established.
A life cycle assessment was performed to quantify the non-renewable (fossil) energy use and global warming potential (GWP) in electricity generation from a typical gas fired combined cycle powerplant in Singapore. The cost of electricity generation was estimated using a life cycle cost analysis (LCCA) tool. The life cycle assessment (LCA) of a 367.5 MW gas fired combined cycle powerplant operating in Singapore revealed that hidden processes consume about 8% additional energy in addition to the fuel embedded energy, and the hidden GWP is about 18%. The natural gas consumed during the operational phase accounted for 82% of the life cycle cost of electricity generation. An empirical relation between plant efficiency and life cycle energy use and GWP in addition to a scenario for electricity cost with varying gas prices and plant efficiency have been established.
On 24th of July 2007 Westinghouse Electric Co. signed landmark contracts with China's State Nuclear Power Technology Corporation (SNPTC), to provide four AP1000 nuclear powerplants in China. The AP1000 is a two-loop 1117 MWe Pressurized Water Reactor (PWR). It is based on proven technology, but with an emphasis on safety features that rely on natural driving forces, such as pressurized gas, gravity flow, natural circulation flow and convection. Ansaldo Nucleare has provided a significant support to the passive plant technology development and, starting from 2000, is cooperating with Westinghouse to development of the AP1000 Plant. In the frame of the AP1000 Chinese agreement, Ansaldo Nucleare, in Joint Venture with Mangiarotti Nuclear, has signed a contract with Westinghouse for the design and the supply of innovative components to be installed in the first AP1000 unit to be ...
The spectrum of training aids used in the nuclear industry runs the gamut from the very basic (i.e., valve training aids - gate, globe, check) to the highly complex (i.e., nuclear full scope simulator). Designing and purchasing the best training aids take much time, detailed investigation, and good understanding of plant operations. The training aid that has given the New York Power Authority the best results has been the motor operator valve (MOV) trainer. Some of the items that make the MOV trainer a good choice are: (1) large number of MOVs in the plant, (2) importance of MOVs to safe plant operation, (3) detailed MOV procedures used by the plant, (4) history of MOV problems, and (5) ability to demonstrate important concepts and operation - hammer blow effect, torque and limit switch adjustment and functions, and actual sequence of operation of the limitorque valve operator.
Due to its important hydroelectric power generation facilities (about 525 plants with a total power of 13,314 MW producing about 35.3 TWh annually) Switzerland plays an important role in the interconnected European power system. Large artificial storage lakes in the Swiss Alps can generate peak power during hours of highest demand: 9700 MW are available from accumulated energy and the total power of pumped-storage facilities amounts to 1700 MW. The latter allow refilling the reservoirs at periods of low power demand and generating power at periods of peak demand. In the case of favorable conditions, the yearly average power production could be increased by 6% and the production during the winter period (October to March) by 20% by the year 2020. However, looking forward to the year 2050, the annual ...
This final report for the Swiss Federal Office for Energy addresses the field of programmable logic controllers and thus investigates a topic that has been neglected up to now - the energy consumption of such controllers. The results of measurements made on programmable logic controllers in use both in operational industrial plants and in the Automation Laboratory at the University of Applied Science in Chur, Switzerland are presented, where a detailed analysis was made on a demonstration plant. Also, technical documentation (catalogues) were evaluated and discussed with experts who had practical experience at their disposal. The results of the study are discussed: these show that the power consumption of any particular programmable logic controller is low in comparison to the energy consumption of the processes that are being controlled. Additionally, it was found that the optimisation of newer devices has to a great ...
An almost primordial trend in the conversion and use of energy is an increased complexity and cost of conversion systems designed to utilize cheaper and more-abundant fuels; this trend is exemplified by the progression fossil fission {yields} fusion. The present projections of the latter indicate that capital costs of the fusion ``burner`` far exceed any commensurate savings associated with the cheapest and most-abundant of fuels. These projections suggest competitive fusion power only if internal costs associate with the use of fossil or fission fuels emerge to make them either uneconomic, unacceptable, or both with respect to expensive fusion systems. This ``implementation-by-default`` plan for fusion is re-examined by identifying in general terms fusion power-plant embodiments that might compete favorably under conditions where internal costs (both economic and environmental) of fossil and/or fission are not as great as is needed to justify ...
A paraboloidal dish solar thermal powerplant produces electrical energy by a two-step conversion process. The collector subsystem is composed of a two-axis tracking paraboloidal concentrator and a cavity receiver. The concentrator focuses intercepted sunlight (direct, normal insolation) into a cavity receiver whose aperture encircles the focal point of the concentrator. At the internal wall of the receiver the electromagnetic radiation is converted to thermal energy. A heat engine/generator assembly, which is mounted directly behind th receiver, then converts the thermal energy captured by the receiver to electricity. Developmental activity has been concentrated on relatively small power modules which employ 11- to 12-m-diam dishes to generate nominal power levels of approximately 20 kW. A comparison of advanced heat engines for use on the dish power module is presented in terms of ...
With regard to the operation of nuclear powerplants, Electricite de France formally recognized in 1973 that it was necessary for safety reasons and economically acceptable to adopt organizational principles of quality assurance that would be applicable both to its own activities and to those of its suppliers. Generally speaking, the form and spirit of the quality assurance programme chosen is based largely on the Code of Practice No. 50-C-QA. In particular, the programme focuses on the flexible character of quality assurance requirements and stresses that in the final analysis product quality depends above all on those to whom the project has been assigned, because it is they who are responsible for meeting the quality objectives set. Ten years of experience with the suppliers of Electricite de France has shown that these suppliers, after some initial difficulty, have been able to adapt the application of quality assurance so as to achieve ...
Various types of nuclear powerplants are being constructed and operated in Korea, and in terms of regulatory control, a method of examining and evaluating the structural integrity of containment structure is being used. Generally, after the construction has been completed, all containment structure go through a Structural Integrity Test(hereinafter SIT) in which the displacement occurring in a structure under greater internal pressure than it was designed for is measured and the result is comparatively assessed with the allowed criteria. Most of the nuclear powerplants in Korea are American type plants and their SIT uses the Invar-wire and Extensometer methods. These existing methods are expected to be used for the APR1400 plant currently being built unless some other reliable alternative technique is presented. This tendency can be observed in other ...
Various types of nuclear powerplants are being constructed and operated in Korea, and in terms of regulatory control, a method of examining and evaluating the structural integrity of containment structure is being used. Generally, after the construction has been completed, all containment structure go through a Structural Integrity Test(hereinafter SIT) in which the displacement occurring in a structure under greater internal pressure than it was designed for is measured and the result is comparatively assessed with the allowed criteria. Most of the nuclear powerplants in Korea are American type plants and their SIT uses the Invar-wire and Extensometer methods. These existing methods are expected to be used for the APR1400 plant currently being built unless some other reliable alternative technique is presented. This tendency can be observed in other ...
Objective: To survey the data for the state of health in the ambient residents of Daya Bay Nuclear PowerPlant, and provide the background data to evaluate the state of health affected by fallout of nuclear powerplant. Methods: The datas were collected by a radiation epidemiology. The investigation was carried out in the area within 20 km of radius from Daya Bay Nuclear' PowerPlant, and the subjects who had lived there for three years or longer before January. 1,1993 and covered by the Household Registry were recruited to a cohort. Results: The mortality rate of overall cancer (per 100 000 PYr) was 88.57 (the standard mortality rate was 79.77 ), the mortality rate of leukemia (per 100 000 PYr) was 3.24 (the standard mortality rate was 2.94), the palpation rate of the goiter in 7-14 years old was 8.34%(9.69% in B ultrasonic), the morbidity rate of newborn's ...
The Nuclear Regulatory Commission (NRC) has sponsored several studies to identify and quantify, through the use of models, the potential health effects of accidental releases of radionuclides from nuclear powerplants. The Reactor Safety Study provided the basis for most of the earlier estimates related to these health effects. Subsequent efforts by NRC-supported groups resulted in improved health effects models that were published in the report entitled {open_quotes}Health Effects Models for Nuclear PowerPlant Consequence Analysis{close_quotes}, NUREG/CR-4214, 1985 and revised further in the 1989 report NUREG/CR-4214, Rev. 1, Part 2. The health effects models presented in the 1989 NUREG/CR-4214 report were developed for exposure to low-linear energy transfer (LET) (beta and gamma) radiation based on the best scientific information available at that time. Since the 1989 report was published, two ...
This thesis surveys the concepts of exergy and extends the exergy method of analysis from the standpoint of its applications to the powerplant systems. After a brief historical review of exergy concepts, the general exergy equation is derived from the combined equation of First and Second Law, and it is shown that any special case of exergy equation is a simplified form of the general exergy equation. The mathematical method for the exergy analysis of a steady-state, steady-flow system, analogous to that of the First Law, is given. The exergy losses in a powerplant are discussed. Then in order to examine these losses, the Second Law performance of major processes of combustion, compression, heat transfer, mixing and throttling have been analyzed analytically, and the exergy efficiencies are defined that accurately assess the thermodynamic performance of the corresponding processes. The methods for ...
Based on the IAPWS technical guidance on ''Instrumentation for Monitoring and Control of Cycle Chemistry for Steam-Water Circuits of Fossil-Fired and Combined Cycle PowerPlants,'' the latest situation regarding instrumentation for nuclear powerplants is discussed. As a result of the discussion, it is concluded that: (1) Reliable and safe operation of plants is established by the application of suitable chemical conditions in plant cooling systems, which should be supported by the selection of suitable control targets for monitoring and by the application of reliable instruments. (2) The minimum level of key instrumentation consists of on-line as well as off-line instruments for monitoring the key parameters: - on-line: pH, conductivity, cation conductivity, O{sub 2} and H{sub 2} concentrations, electrochemical corrosion ...
Japan's first water power station to provide public power was the Keage plant (maximum output 160 kW) which began operation in 1891. The installed capacity of pure hydro plants reached 20 481 MW in March 1991; pumped-storage powerplants account for 17 004 MW, making a total of 37 483 MW. Pumped-storage thus represents 45 per cent of total hydro capacity. Pure hydro plants under construction at the end of March 1990 totalled 75, representing 968 MW of capacity. There were also seven pumped-storage plants under construction (each more than 300 MW). The latest survey to establish the hydro potential of Japan indicated the gross theoretical hydro potential to be 717 600 GWh/year and the exploitable potential to be 130 524 GWh/year. Of this exploitable potential, 60 per cent is in operation and 3 per cent is under construction. The exploitable potential ...
A cost study is described which compared the economics of four dry/wet cooling systems to use at the existing Raft River Geothermal Plant. The results apply only at this site and should not be generalized without due consideration of the complete geothermal cycle. These systems are: the Binary Cooling Tower, evaporative condenser, Combin-aire, and a metal fin-tube dry cooling tower with deluge augmentation. The systems were evaluated using cooled, treated geothermal fluid instead of ground or surface water in the cooling loops. All comparisons were performed on the basis of a common plant site - the Raft River 5 MWe geothermal plant in Idaho. The Binary Cooling Tower and the Combin-aire cooling system were designed assuming the use of the isobutane/water surface condenser currently installed at the Raft River Plant. The other two systems had the isobutane ducted to the evaporative condensers. Capital ...
This is a build-and-scrap-and-build job, in which a new No. 1 generator is constructed while the existing plant stays in operation in the same site. Since interference between the new and the existing systems are unavoidable in such work, protection is sufficiently provided and measurements are frequently performed when the work comes to involve important structures positioned close to each other, such as the existing No. 1 and No. 2 OF (oil-filled) cables transmitting power from the existing powerplant to Minami-Yokohama Substation of Tokyo Electric Power Co., Ltd., and the newly planned discharge channel or the existing covered sewerage and the newly planned discharge outlet. Now that the newly planned discharge channel intercepts the OF cables at three places and is installed to pass under the existing cable duct, it once happened that the duct supporting piles were severed for ...
The Greek energy economy in response to the rising energy demand yielded to the pressure to develop new sources, particularly since the early closing of the Aliveri mine was approaching. The well known lignite deposits in the Megalopolis Basin, with approximately 380 MMt of economically recoverable fuel, had remained undeveloped since its low heat value, averaging 4012 kJ (960 kcal/kg), had been considered in all countries of the world to be of too poor quality to be economically usable in thermal powerplants. With the onset of energy shortages in Greece, which in the course of the year 1967 led to intermittent interruptions of power, finally induced the Public Power Corp., within a German economic assistance agreement to advertise an idea competition among German consortia. In 1967 various planning consortia submitted their plans for the treatment of the Megalopolis open-pit mine and for the laying ...
This paper presents a practical case study on the dynamic stability of the Saudi Electricity Company (SEC) power system and its effect on increasing power transfer limit of the interconnection between Eastern Operating Area (SEC-EOA). The problem of optimal tuning of the power system stabilizer parameters was converted into optimization problem wth eigenvalue-based objective functions, which was then solved by genetic algorithms. In this regard, two eigenvalue-based objective functions were considered and the problem is solved using real-coded genetic algorithm (RCGA). The effectiveness of the suggested technique to enhance the power system dynamic stability and to extend the power transfer capability limit of the SEC-EOA and the SEC-EOA power system was verified through a comprehensive eigenvalue analysis and time-domain nonlinear simulation. The results also ...
The ROP margin in a CANDU reactor is decreasing over time due to the Primary Heat-Transport System (PHTS) aging effect. Adjustment of the ROP trip setpoint is required to maintain a high trip-probability and ROP trip effectiveness. Especially, for Wolsong-1, which is scheduled to change the old pressure tubes in 2009, the trend of ROPT after the retubing should be reevaluated. Before setting a ROPT, the main thermal characteristics including Critical Channel Power (CCP) should be calculated by the NUCIRC code. In this paper, the thermalhydraulic evaluation for Wolsung-1 was conducted with the updated Wolsung-1 PHTS data. Specifically, for the case of 0 EFPY (Effective Full Power Year) and 11 EFPY after the retubing, the distribution of the channel flow rate, channel exit quality, critical channel power, and critical power ratio (CPR) of the Wolsong-1 aged plant are calculated
This report summarizes a public workshop that was held on April 27, 1999, in Rockville, Maryland. The workshop was conducted as part of the US Nuclear Regulatory Commission's (NRC) efforts to further develop its understanding of the risks associated with low power and shutdown operations at US nuclear powerplants. A sufficient understanding of such risks is required to support decision-making for risk-informed regulation, in particular Regulatory Guide 1.174, and the development of a consensus standard. During the workshop the NRC staff discussed and requested feedback from the public (including representatives of the nuclear industry, state governments, consultants, private industry, and the media) on the risk associated with low-power and shutdown operations.
This paper uses multi-pass iteration particle swarm optimization (MIPSO) to solve short term hydroelectric generation scheduling of a power system with wind turbine generators. MIPSO is a new algorithm for solving nonlinear optimal scheduling problems. A new index called iteration best (IB) is incorporated into particle swarm optimization (PSO) to improve solution quality. The concept of multi-pass dynamic programming is applied to modify PSO further and improve computation efficiency.The feasible operational regions of the hydro units and pumped storage plants over the whole scheduling time range must be determined before applying MIPSO to the problem. Wind turbine power generation then shaves the power system load curves. Next, MIPSO calculates hydroelectric generation scheduling. It beg...
Severe accident analysis has been performed for the Wolsung nuclear powerplants in Korea to investigate severe accident phenomena of CANDU-600 reactors as a part of Level II PSA study. The accident sequence analyzed in this paper is loss of active heat sinks (LOAH) which is caused by loss of off-site power, diesel generators, and DC power, ISAAC(Integrated Severe Accident Analysis Code) computer code developed by KAERI (Korea Atomic Energy Research Institute) was used in this analysis. This paper describes the important thermal-hydraulics and source term behaviors in the primary system and inside containment, and the failure mechanisms of calandria vessel and containment. In addition, some insights for accident management program (AMP) are also given.
Recently it is strongly required to reduce energy consumption to cope with the global warming. Since energy consumption in commercial and residential sectors are increasing while industrial sector is almost constant in Japan, policies to lead energy conservation in urban areas is quite important. This study aims at investigating the performance of urban energy systems which install combined heat and power (CHP) as a district heating and cooling (DHC) plant and the influence of CHP on the structure of electric power systems of utilities. The behavior of energy technologies and the possibility of energy conservation are evaluated based on an optimization model with respect to total system cost. Sensitivity analysis of population allocation into urban areas indicates that fossil fuel consumption varies in the range of 10--20% compared with conventional systems.
Purpose: To provide a feedwater control device capable of minimizing the adverse response of steam drum level at low power. Consitution: In order to perform feedwater control at low power by the substantial control of three factors, that is, main steam flow rate, feedwater flow rate and steam drum level, the main steam flow rate is determined from the reactor output and feedwater rate is determined from the changes in the feedwater temperature due to the mixing of waters in the reactor clean up system and feedwater. If a difference is resulted between these flow rates, a starting feedwater regulator is controlled instantly to eliminate the difference. The water level in the steam drum is used for amending the difference from the final set value of the drum water level, by which the adverse response of the steam drum level can be minimized. (Seki, T.).
ALSTOM Power Inc.'s PowerPlant Laboratories (ALSTOM) has teamed with the U.S. Department of Energy National Energy Technology Laboratory (DOE NETL), American Electric Company (AEP) and Parsons Energy and Chemical Group to conduct a comprehensive study evaluating coal fired steam powerplants, known as Rankine Cycles, equipped with three different combustion systems: Pulverized Coal (PC), Circulating Fluidized Bed (CFB), and Circulating Moving Bed (CMB{trademark}). Five steam cycles utilizing a wide range of steam conditions were used with these combustion systems. The motivation for this study was to establish through engineering analysis, the most cost-effective performance potential available through improvement in the Rankine Cycle steam conditions and combustion systems while at the same time ensuring that the most stringent emission performance based on CURC (Coal ...
Since the mid-1990s, nuclear powerplants in Korea have experienced wall thinning, leaks, and ruptures of secondary side piping caused by flow-accelerated corrosion (FAC). The pipe failures have increased as operating time progresses. In order to prevent the FAC-induced pipe failures and to develop an effective FAC management strategy, KEPRI and KOPEC have conducted a study for developing systematic FAC management technology for secondary side piping of all Korean nuclear powerplants. As a part of the study, FAC analyses were performed using the CHECWORKS code. The analysis results were used to select components for inspection and to determine inspection intervals on each nuclear powerplant. This paper describes the introduction of the FAC analysis method and the wall thinning trend analysis results by reactor type, system, and water treatment amine. This ...
To understand the environmental dispersion trend of "3H and "1"4C discharged from the Wolsung nuclear powerplant, the present levels of "3H and "1"4C in environmental samples in the vicinity of the Wolsong site were studied. During 1992 through 2002, the annual means of HTO and "1"4C concentrations in air collected at three sampling stations around Wolsong nuclear powerplant were in the range of 1.13 #approx# 29.2 Bq m"-"3 and 0.33 #approx# 0.40 Bq g-C"-"1 respectively, decreasing with distance from the site. The annual mean of TFWT concentrations in pine needle was in the range of 104 #approx# 790 Bq L"-"1 at N-1 and 62.8 #approx# 298 Bq L"-"1 at S"-"2, while the annual mean of "1"4C concentration was in the range of 0.335 #approx# 0.897 g-C"-"1 at N-1 and 0.254 #approx# 0.332 Bq g-C"-"1 #approx# at S"-"2, showing elevated value than a 0.25 Bq g-C"-"1 of background level. (author)
In this paper, we calculated the radioactive concentration distribution of radioactive waste water, the temperature distribution of drained cooling water and the effect of implement from the Daya Bay Nuclear PowerPlant on nearby waters range, discussed and analysed some problems of computational results and computation with Alternating Direction Implicit Method (ADI). The contents of the article included: the establishment of two-dimension tidal current equation, radioactive waste water pollutant dispersion equation and cooling water heat convection diffusion equation, the numerical difference calculation model of tidal current field, concentration field as well as temperature field, effect impingement with ADI method, numerical calculation results. The result of research showed that: when the Daya Bay Nuclear PowerPlant is on normal operation and after the low level radioactive waste water and low ...
As a basic research to consider aging deterioration of the operating nuclear powerplant to seismic fragility analysis, aging deteriorations occurring safety related equipment of both Kori unit 1 and Wolsung unit 1, are investigated in this study. First of all, 378 and 152 safety related equipment are selected at Kori unit 1 and Wolsung unit 1 respectively. Seismic review team including seismic capability engineer, is organized and seismic walkdown is carried out using the nondestructive tests. As a results of seismic walkdown, crack is a typical aging deterioration which can reduce the seismic safety of safety related equipment and the other aging deteriorations such as concrete compressive strength, corrosion, and tightness of anchor bolt, have a much smaller influence than crack. In order to manage the aging deterioration data collected through the seismic walkdown in effective and systematic, EDS(Evaluation of Deteriorated System) DB is ...
As a basic research to consider aging deterioration of the operating nuclear powerplant to seismic fragility analysis, aging deteriorations occurring safety related equipment of both Kori unit 1 and Wolsung unit 1, are investigated in this study. First of all, 378 and 152 safety related equipment are selected at Kori unit 1 and Wolsung unit 1 respectively. Seismic review team including seismic capability engineer, is organized and seismic walkdown is carried out using the nondestructive tests. As a results of seismic walkdown, crack is a typical aging deterioration which can reduce the seismic safety of safety related equipment and the other aging deteriorations such as concrete compressive strength, corrosion, and tightness of anchor bolt, have a much smaller influence than crack. In order to manage the aging deterioration data collected through the seismic walkdown in effective and systematic, EDS(Evaluation of Deteriorated System) DB is ...
Purpose: To permit accurate detection of sodium leakage by distinguishing between variations in the overflow tank level due to changes in sodium temperature accompanying changes in the power level or operating state of a liquid metal sodium cooled fast breeder, and a reduction in power level due to duct leakage. Constitution: The volume of sodium in the primary cooling system is roughly estimated from the temperatures of hot and cold legs, and the duct leak preset level with respect to the sodium liquid level within an overflow tank when the plant is normal is varied according to the state of the plant. More particularly, the volume of sodium within the overflow tank is calculated on the basis of a signal representing the liquid level detected by a liquid level gauge in the overflow tank and a signal representing the temperature detected by hot leg and cold leg thermometers, thereby obtaining the preset ...
Nowadays the safety of Nuclear PowerPlants is becoming more and more significant. Therefore consideration of severe accidents shall be included in both design and operating process of Nuclear PowerPlants. In particular ground motion forms one of the important natural hazards. For structural analysis both linear-elastic and non-linear methods are specified by the engineering codes for earthquake resistance design. However, time history analysis is required for investigation of non-linear structural behaviour. Moreover, non-linearities are often caused by the presence of damage. This can be detected by means of structural health monitoring and subsequently system identification. In this paper the advantages of both dynamic time history analysis and damage detection by means of wavelet analysis are discussed. First, the non-linear behaviour of a frame structure due to an artificial earthquake motion is ...
Decomposition of organic compounds contained in the spent ion exchange resins is considered effective in reducing the waste volume. A system using the wet-oxidation process has been studied for the treatment of the spent resins stored at Trino Nuclear PowerPlant owned by SOGIN. Compared with various processes for treating sludge and resin, the wet-oxidation system is rather simple and the process conditions are mild. Not contaminated ion exchange resin samples similar to those ones used in Trino NPP were processed by wet-oxidation and appropriate decomposition of the organic compounds was verified. After decomposition the residue can be solidified with cement for final disposal. When compared with direct solidification without decomposition, the number of waste packages can be significantly reduced. Additional measures for conditioning secondary waste products have also been studied, and their applicability to the Trino Nuclear ...
Postulated impacts of large energy releases were examined in the light of existing technical information. The magnitudes of direct atmospheric modifications were estimated, and the ecological and economic implications of the modifications were explored. Energy releases from energy centers (10 to 40 powerplants at a single site) and individual powerplant clusters (1 to 4 powerplants) were considered. In the atmosphere the energy will exist initially as increased temperature (sensible heat), moisture (latent heat), and air motion (kinetic energy). Addition of energy could result in increased cloudiness and fog, and changed precipitation patterns. A framework for economic analysis of the impacts of the postulated atmospheric modifications was established on the basis of costs and benefits. Willingness-to-pay was selected as the appropriate measure for valuing ...
In this work, a model for determining the optimal inspection and replacement periods of the safety system in Wolsung Nuclear PowerPlant Unit 1 is developed, which is to minimize economic loss caused by inadvertent trip and the system failure. This model uses cost benefit analysis method and the part for optimal inspection period considers the human error. The model is based on three factors as follows: (i) The cumulative failure distribution function of the safety system, (ii) The probability that the safety system does not operate due to failure of the system or human error when the safety system is needed at an emergency condition and (iii) The average probability that the reactor is tripped due to the failure of system components or human error. The model then is applied to evaluate the safety system in Wolsung Nuclear PowerPlant Unit 1. The optimal replacement periods which are calculated with ...
The ability to monitor the corrosion degradation of key components in fossil fuel powerplants is of utmost importance for Futuregen and ultra-supercritical powerplants. Fireside corrosion occurs in the high temperature sections of energy production facilities due to a number of factors: ash deposition, coal composition, thermal gradients, and low NOx conditions, among others. Problems occur when equipment designed for either oxidizing or reducing conditions is exposed to alternating oxidizing and reducing conditions. This can happen especially near the burners. The use of low NOx burners is becoming more commonplace and can produce reducing environments that accelerate corrosion. One method of addressing corrosion of these surfaces is the use of corrosion probes to monitor when process changes cause corrosive conditions. In such a case, corrosion rate could become a process control variable that ...
Object: To prevent coolant inventory within a cooling system loop in an atomic powerplant from being varied depending on loads thereby relieving restriction of varied speed of coolant flow rate to lowering of a liquid surface due to short in coolant. Structure: Instruments such as a superheater, an evaporator, and the like, which constitute a cooling system loop in an atomic powerplant, have a plurality of free liquid surface of coolant. Portions whose liquid surface is controlled and portions whose liquid surface is varied are adjusted in cross-sectional area so that the sum total of variation in coolant inventory in an instrument such as a superheater provided with an annulus portion in the center thereof and an inner cylindrical portion and a down-comer in the side thereof comes equal to that of variation in coolant inventory in an instrument such as an evaporator similar to the superheater. which ...
An investigation was carried out to determine the significance of a large input of cogeneration units for the electric power generation, next to the input of coal and uranium. Thereto a production plant has been set up to generate heat and electric power. The plant serves as a basis for a number of comparative calculations: basic calculations to investigate the influence of some strategies on the cogeneration input, and sensitivity calculations to determine the influence of a few changes in the starting points. Some variants have been deduced from this plant, which is based on prognosis for the year 2000. By means of the computer calculation program OPINIE (Optimale Inzet en Instelling van Eenheden: Optimal Input and Installation of Units) the minimal variable costs were calculated for different situations. Finally for each considered situation the total annual costs have been ...
The program package COSYMA for assessing the radiological and economic consequences of nuclear accidents, developed with the support of the European Commission, was applied to investigate the health effects and risks from accidental releases of radioactive material from the Daya Bay nuclear powerplant. Population distribution data in the range of 80 km around the site and hourly meteorological data for the year 1985 representative of accident consequence analysis were used. The results showed that early effects are more important at distances closer to the site, while the number of fatal cancers is closely related to the population density and the late effects are still important at distances larger than 50 km from the site. The mean annual expected values for early mortality and late mortality estimated for the population within a circle of 80 km around the Daya Bay nuclear powerplant are 4.5x10"-"3 ...
Modern combined cycle powerplants with natural gas as the only fuel reach efficiencies of up to 55% for electric power generation. Nevertheless the reserve of natural gas is more limited compared to the reserve of coal. Therefore possibilities should be investigated to use coal for such plants also. One concept, that combines the use of coal in a combined cycle application with high efficiencies is examined in this paper. According to this concept the exhaust gas of the gas turbine (vitiated air) is the combustion air for the pulverized coal combustion, that takes place in the bottoming steam generator. Due to the low oxygen content of the vitiated air the burnout of the coal may be incomplete. In order to avoid the incomplete combustion of the coal and the resulting decrease of the efficiency of the plant and possible emission problems, a catalyst, that converts carbon monoxide ...
In this report, the concept of exergy and the general methodology of the exergetic analysis and the thermoeconomic (combined exergetic and economic) analysis of energy conversion systems are presented. The THESIS (THermodynamic and Economc SImulation System) computer program used for these analyses is briefly described. Detailed mass, energy, exergy and money balances for a reference steam powerplant (Harry Allen Station) are shown. The effect of the most important process parameters on the overall efficiency is investigated. A year-by-year and a levelized revenue requirement analysis are presented. The costs of exergy losses are compared with the capital costs and other expenses due to owning and operating each particular plant component. The question whether it is profitable to reduce the exergy losses by increasing these costs and vice versa is investigated. A cost sensitivity analysis including the effect of coal price ...
Methodology based on probabilistic fracture mechanics (PFM) is finding increasing acceptability in demonstrating safety of Nuclear PowerPlant (NPP) piping. In PFM, the methods of fracture mechanics and reliability theory are combined for assessing the reliability of components, which contain cracks. In this work, reliability assessment of Tarapur Atomic PowerPlant (TAPP) 3-4 Primary Heat Transport (PHT) piping is done using PFM. Monte Carlo simulation with stratified sampling is used as a variance reduction technique. PFM model assumes a pre-existing circumferential surface crack before the start of plant operation. The crack grows in size during the lifetime of the plant due to the fatigue loading. This part-through wall crack having escaped hydro-test and pre-service inspection, may result in either a through wall flaw (leak) or may lead to the rupture of ...
The first section of this Handbook describes hydro-electric projects currently under construction or recently commissioned in a number of countries. The major part of the Handbook is devoted to lists of data relating to hydro-electric plants and hydromachinery. These include: data for 1990 submitted by national power authorities on hydro-electric and pumped-storage plants in operation, under construction or planned; more detailed data for pumped-storage plants; country by country data on the dimensions, and reservoir and electrical capacity of major dams and hydro plant; a listing of roller compacted concrete dams; a listing of the world's largest turbines giving data on the largest unit at each scheme in rank order ranging from a unit capacity of 838 MV down to 147 MV; a similar list of the largest hydrogenerators ranging from a unit capacity of 825 MVA down to 150 MVA; ...
The real thermodynamic inefficiencies in a thermal system are related to exergy destruction and exergy loss. An exergy analysis identifies the system components with the highest exergy destruction and the processes that cause them. However, only a part of the exergy destruction in a component can be avoided. A minimum exergy destruction rate for each system component is imposed by physical, technological, and economic constraints. The difference between the total and the unavoidable exergy destruction rate represents the avoidable exergy destruction rate, which provides a realistic measure of the potential for improving the thermodynamic efficiency of a component. The calculation of avoidable cost rates associated with both exergy destruction and capital investment is described in the paper and is applied to the exergoeconomic evaluation of an externally fired combined cycle powerplant. For each plant component, avoidable ...
The leak before break (LBB) concept is difficult to apply to a structure with a thin tube that is immersed in a water environment. A heat exchanger in a nuclear powerplant is such a structure. The present paper addresses an application of the LBB concept to a heat exchanger in a nuclear powerplant. The minimum leaked coolant amount containing the radioactive material which can activate the radiation detector device installed near the heat exchanger is assumed. The postulated initial flaw size that cannot grow to the critical flaw size within the time period to activate the radiation detector is justified. In this case, the radiation detector can activate the warning signal caused by coolant leakage from initially postulated flaws of the heat exchanger. The nuclear plant can safely shutdown when this occurs. Since the postulated initial flaw size can not grow to the critical flaw ...
Wolsong 2, 3, and 4 are CANDU 6 pressurized heavy water nuclear powerplants, each with a gross electrical output of 715 MW(e). The plants were constructed in the Republic of Korea during the 1990s. The three Wolsong units are based on the previous CANDU Wolsong Unit 1, declared in service in 1983. All four units are presently in commercial service. The Wolsong abnormal operating manuals were developed in a cooperative effort between Atomic Energy of Canada Limited, Korea Power Engineering Company staff, and Korea Electric Power Corporation. The role of Atomic Energy of Canada Limited in performing risk assessment studies and supporting CANDU stations for the preparation of emergency operating procedures has greatly benefited the Wolsong abnormal operating manual program. Korea Electric Power Corporation provided training and supervision, Korea ...
Total EU (and Norway) emissions of CO_2 from thermal power generation were some 950 million tonnes in 1990, the Kyoto agreement reference level. An ongoing research project, the GESTCO project, will provide the first documentation that, for the emission sources within the selected key areas, sufficient geological storage capacity is available for at least 30 years and possibly much longer. Cost of energy will obviously increase, but it is anticipated that electricity production cost price will be comparable to that of renewables. It would further have major implications for the European power generating industry which today is totally dominated by fossil fuel combustion with enormous emissions problems. The identification and siting of subsurface CO_2 storage capability can be expected to have considerable effect on the planning for and future siting of fossil fuel plants. In Norway there are plans to build several major, ...
Wet limestone scrubbing is once again becoming a popular technology for removal of sulfur dioxide (SO{sub 2}) from powerplant emissions. Critical to the operation of wet limestone flue gas desulfurization (FGD) systems is accurate chemical analysis of scrubber solids. The analytical technique of thermogravimetry is ideal for this application, as the instrument can give precise readings of the principal scrubber solids components, calcium sulfite/sulfate hemihydrate, calcium sulfate dihydrate (gypsum), and unused calcium carbonate. The data provides plant chemists, engineers, and operators with information needed to fine-tune scrubber operation and detect process upsets. (orig.)
The river Saale cascade consists of seven reservoirs with a total capacity of approx. 415 Mio. m[sup 3]. The entire reservoir system covers a catchment area of 1665 km[sup 2]. The water management tasks extend to the following main fields: flood protection upkeep of minimum water stock, salt load control and power generation. The energy supply capacity of the cascade is mainly used by pumped storage plants. The last of these plants, Hohenwarte II, was put into service in 1963. (orig.)
Generally, Hardening and irradiated brominating phenomena are occurred in the reactor vessel under operation conditions by atomic cavities and creation of impurity atoms which are led by high fast neutron flux. To assure the mechanical integrity of pressure vessel until the end of powerplant life after monitoring the sample specimens on the vessel inside, a series of tests is performed over the retrieved surveillance capsule to examine the changes according to the plant operation in accordance with regulations. Monitoring surveillance capsules attached to neutron shield wall of outer core are consists of impact sample, tensile sample and temperature monitor
This article addresses the possibility that electric utilities may not have enough generating capacity to meet the demands on their systems at some future date as a result of a recent spate of plant-construction cancellations, especially of nuclear facilities. It emphasizes that, when that time arrives, utilities will be willing to try every conceivable possibility for preserving the integrity of their systems, and offers differential pricing of electricity as one such possibility. The article also offers a regional analysis of the effect of plant cancellations and of the potential for differential pricing as a preventative of power shortages. 5 tables.
Rubber lining is used as a corrosion protection material in European flue gas desulfurization plants, for scrubbers, tanks, pipe systems, etc. Although these rubber linings can last more than 15 years, relining still is necessary. The difficulty of shutting down power station units requires that the time scale of this replacement be kept to a minimum. High-pressure water systems have proven successful as an efficient method for removal of the old lining. The working steps and time scale are demonstrated for one such relining case.
Severe accident management can be defined as the use of existing and alternative resources, systems, and actions to prevent or mitigate a core-melt accident in nuclear powerplants. TRAIN (Training pRogram for AMP In NPP), developed for training control room staff and the technical group, is introduced in this report. The TRAIN composes of phenomenological knowledge base (KB), accident sequence KB and accident management procedures with AM strategy control diagrams and information needs. This TRAIN might contribute to training them by obtaining phenomenological knowledge of severe accidents, understanding plant vulnerabilities, and solving problems under high stress. 24 refs., 76 figs., 102 tabs. (Author)
We consider energy investment, when a choice has to be made between fossil fuel and biomass fired production technologies. A dynamic model is presented to illustrate the effect of the different degrees of input price uncertainty on the choice of technology and the timing of the investment. It is shown that when the choice of technology is irreversible, it may be optimal to postpone the investment even if it would otherwise be optimal to invest in one or both of the plant types. We provide a numerical example based on cost, estimates of two different powerplant types. (author)
FLOWER, a computer code recommended by USNRC for assessing the environmental impact in tidal regions, was adapted and improved so as to be suitable to deal with the influence of drift stream along seashore to the dilution of contaminants and heat in the bay mouth. And the code outputs were presented with more mid-results such as average concentrations and temperature values for all tides considered. Finally, the modified code is applied to the dispersion calculation of heat and liquid effluents from Daya Bay Nuclear PowerPlant, and the impacts from routine operation of the plant on Daya Bay sea waters were given.
Most important radionuclides naturally appearing in minerals used to form building materials are described. The frequently met ranges of concentrations of these radionuclides in the building materials composed from natural products as well as from power-plant wastes and metallurgic plant wastes are discussed and propositions concerning the limitation of presence of radioactive nuclides in the building materials are given, with special concern paid to materials for dwelling and public utility buildings. The elaborated technique of measuring potassium 40, radium 226 and thorium 228 concentrations is presented. Data on the organization of controlling-and-measuring laboratories in this field are given. (author).
The design of a solar heated cavity receiver transferring 60 MW of thermal energy to the working medium (air) for a closed-cycle gas turbine is described. The gas turbine plant with its cycle layout is presented. Then the tubes for the receiver are designed taking into account thermal and mechanical loads. It is shown how the occurring stresses are influenced by the destribution of the locally absorbed hat flux. Calculations for an existing coal fired air heater of a closed-cycle gas turbine give a first impression of the long-term behaviour to be expected of the receiver tubes.
In the scope of the nuclear plants lifetime study, the behavior of the cooling towers is discussed. The main geometrical characteristics of the cooling towers in the French nuclear powerplants, are presented. The surveyance program, the risks of accident, the research and development actions are considered. The results of the investigations of the cooling tower structure show that it is a multidiciplinary problem and needs the development of experimental and theoretical methods. Concerning the regenerators, the surveyance actions under operating conditions, the accelerated aging tests, and some aspects of the mechanical resistance, are underlined. It is shown that mainly the creep tests will allow the lifetime estimation of the materials developed for the regenerators.
The role of robotics and remote handling equipment in future nuclear powerplant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.
The role of robotics and remote handling equipment in future nuclear powerplant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.
A process has been developed that exploits the characteristics of microwave heating for the vitrification of high-level radioactive liquid waste. This process, microwave vitrification, has been successfully operated at pilot plant scale in an active cell using simulated liquid waste containing several curies of radioactivity. Excellent decontamination factors have been achieved for both volatiles and nonvolatiles with an average ruthenium decontamination factor of 490 and a gross alpha emitter decontamination factor of 100,000. Almost all the radioactivity is incorporated in a glass block.
A process has been developed that exploits the characteristics of microwave heating for the vitrification of high-level radioactive liquid waste. This process, microwave vitrification, has been successfully operated at pilot plant scale in an active cell using simulated liquid waste containing several curies of radioactivity. Excellent decontamination factors have been achieved for both volatiles and nonvolatiles with an average ruthenium decontamination factor of 490 and a gross alpha emitter decontamination factor of 100,000. Almost all the radioactivity is incorporated in a glass block.
The Jansen pumped-storage plants owned by Bayernwerk Wasserkraft AG are located on the river Pfreimd in eastern Bavaria, Germany. The group comprises the three powerplants at Reisach, Tanzmuehle and Trausnitz, as well as the Rabenleite upper reservoir and two weirs. After forty years of service, the powerplant group has recently been rehabilitated. The rehabilitation and modernization scheme included, inter alia, replacing the surface sealing on the upstream side of the upper reservoir dam, installing a state-of-the-art leakage and stability monitoring system, and renewing the instrumentation and control equipment in the powerplants and in the central control room. Finally, the paper describes the operating experience with the new I and C systems. (orig.) [German] Die Pumpspeicherkraftwerke Jansen der Bayernwerk Wasserkraft AG befinden ...
Due to the cyclical human life, utility loads appear to be cyclical too. During daytime when most factories are in operation, the electricity demand is very high. On the contrary, when most people are sleeping from midnight to daybreak, the electric load is very low, usually only half of the peak load amount. To meet this large gap between peak load and light load, utilities must idle many generation plants during light load period while operating all generation plants during peak load period no matter how expensive they are. This low utilization factor of generation plants and uneconomical operation have sparked utilities to invest in energy storage devices such as pumped storage plants, compressed air energy storage plants, battery energy storage systems (BES) and superconducting magnetic energy storage systems (SMES) etc. Among these, pumped storage is already commercialized and ...
Geologically estimated natural gas resources are 500 Tcm. With the advance in geological science increase of estimated resources is expected. Natural gas reserves in 2000 have been proved to be around 165 Tcm. As it is known the reserves are subject to two constraints, namely: capital invested in the exploration and drilling technologies used to discover new reserves. The natural gas scarcity factor, i.e. ratio between available reserves and natural gas consumption, is around 300 years for the last 50 years. The new discovery of natural gas reserves has given rise to a new energy strategy based on natural gas. Natural gas utilization is constantly increasing in the last 50 years. With new technologies for deep drilling, we have come to know that there are enormous gas resources available at relatively low price. These new discoveries together wth high demand for the environment saving have introduced a new energy strategy on the world scale. This paper presents an evaluation of the ...
Geologically estimated natural gas resources are 500 Tcm. With the advance in geological science increase of estimated resources is expected. Natural gas reserves in 2000 have been proved to be around 165 Tcm. As it is known the reserves are subject to two constraints, namely: capital invested in the exploration and drilling technologies used to discover new reserves. The natural gas scarcity factor, i.e. ratio between available reserves and natural gas consumption, is around 300 years for the last 50 years. The new discovery of natural gas reserves has given rise to a new energy strategy based on natural gas. Natural gas utilization is constantly increasing in the last 50 years. With new technologies for deep drilling, we have come to know that there are enormous gas resources available at relatively low price. These new discoveries together with high demand for the environment saving have introduced a new energy strategy on the world scale. This paper presents an evaluation of the ...
Secondary energy can be described as a surplus of electrical energy in a hydropower because the lower demand of energy in some period of the day and the excess of water in the reservoir during the rainy periods. This study proposes the using of the excess of energy at Itaipu Bi nacional for electrolytically hydrogen production and ammonia for nitrogenous fertilizers. Ammonia is a raw material for nitrogenous fertilizers synthesis and produced using hydrogen and nitrogen from the atmosphere. This paper determines the minimal cost of hydrogen production and the capacity of hydrogen production, with this data and according the ammonia market for nitrogenous fertilizers in the Centre/South region was estimated the better capacity of ammonia production for one plant near Itaipu. The process of ammonia production using energy excess is the most environmental acceptable. (author)
This user's guide describes BNW-III, a computer code developed by the Pacific Northwest Laboratory (PNL) as part of the Dry Cooling Enhancement Program sponsored by the US Department of Energy (DOE). The BNW-III code models a modular dry/wet cooling system for a nuclear or fossil fuel powerplant. The purpose of this guide is to give the code user a brief description of what the BNW-III code is and how to use it. It describes the cooling system being modeled and the various models used. A detailed description of code input and code output is also included. The BNW-III code was developed to analyze a specific cooling system layout. However, there is a large degree of freedom in the type of cooling modules that can be selected and in the performance of those modules. The costs of the modules are input to the code, giving the user a great deal of flexibility.
The transport of air pollutants in coastal regions has been known to be strongly affected by the mesoscale atmospheric circulations such as sea-land breezes. These mesoscale atmospheric circulations depend on synoptic weather conditions. In this study, a three-dimensional sea-land breeze model was developed to evaluate the effects of the sea and land breezes on the atmospheric dispersion of radioactive materials released from nuclear powerplants in Korea. In the model, the hydrostatic primitive equations in the terrain-following coordinate system were used. The mesoscale atmospheric circulation simulation were carried out under various synoptic weather conditions for all seasons around the Wolsung nuclear powerplant site.
The transport of air pollutants in coastal regions has been known to be strongly affected by the mesoscale atmospheric circulations such as sea-land breezes. These mesoscale atmospheric circulations depend on synoptic weather conditions. In this study, a three-dimensional sea-land breeze model was developed to evaluate the effects of the sea and land breezes on the atmospheric dispersion of radioactive materials released from nuclear powerplants in Korea. In the model, the hydrostatic primitive equations in the terrain-following coordinate system were used. The mesoscale atmospheric circulation simulation were carried out under various synoptic weather conditions for all seasons around the Wolsung nuclear powerplant site.
Many powerplants use treated surface water as boiler feedwater and have difficulties in keeping within the limits for organic substances in feedwater (TOC < 200 ppb) or acid conductivity in steam condensate (< 0.2 {mu}S/cm). The characteristics of surface water and the role of organic substances in boiler feedwater are explained and discussed. [German] Viele Kraftwerke bereiten fuer die Erzeugung von Kesselspeisewasser Oberflaechenwasser auf und haben Probleme, die Richtlinien fuer organische Stoffe im Speisewasser (TOC < 200 ppb) oder Saeure-Leitfaehigkeit in Dampfkondensaten (< 0,2 {mu}S/cm) einzuhalten. Die besonderen Eigenschaften von Oberflaechenwaessern und die Bedeutung organischer Stoffe in Kesselspeisewasser werden erlaeutert und diskutiert. (orig.)
This final report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that involves the building of a joint biogas plant serving 60 farmers and industrial companies with an annual processing capacity of 45,000 tons. The plant is to produce biogas to be fed into the gas mains and will not only reduce nutrient loading in a region with an extensive livestock industry but also reduce carbon dioxide emissions by using the gas as a motor fuel. The importance of the project with respect to both the environment and energy policy-making is discussed and the costs involved are examined. Details are presented on the technology used and on the material flows involved. Figures are quoted on energy production. The various biogenic substrates used, such as food wastes, waste oils, cereal wastes and used mushroom substrates, are discussed, as is the use of the solid and liquid outputs of the digester in farming activities.
In the last years, the growing demand for air conditioning has caused a significant increase in demand for primary energy resources. Solar-powered cooling is one of the technologies which allows to obtain, by using the renewable solar source, an important energy saving compared to traditional air conditioning plants. The paper describes different technical installations for solar cooling, their way of operation, advantages and limits. The objective of the present study has been to analyze the technical and economic feasibility of solar absorption cooling systems, designed for two different application fields: industrial refrigeration and air conditioning. The possibility to replace or integrate the existing plants is studied, by considering the refrigeration requirements of a company, whic...
After explaining the main causes for the limited power output of turbine generators with 50 s"-"1, the limits for superheated-steam turbines and for saturated-steam turbines are given. A comparison of the economy in the limiting output range (1,200 MW) shows that half load plants as well as two-shaft turbine generators do not bring any advantages as compared with a single-shaft turbine generator. For the selection of speed of the single-shaft turbine generator the planned way of application is decisive. For base load plants already a speed of 25 s"-"1 is economic in this power range. Concluding, some design features and problems of development for such large turbines with 25 s"-"1 for conventional steam conditions are discussed. (orig.).
Studies technological safety of installing a water spray pressure vessel between electrostatic dedusters and coal sludge ducts. These sprays are in use elsewhere for steam generator ash removal. Dust ignition and explosion tests were carried out to examine flame and pressure wave propagation through the vessel into ducts. Water jet diameter, amount of water sprayed and coal dust removed were varied. Pressure waves exceeded 250 Pa. Test results show the vessel to be suitable for installation in briquetting plants due to its flame and explosion barrier effect and extermination of smoldering dust fires. The only disadvantage of the vessel is seen as its water and electric power consumption; about 8/sup 3//h of water and 1.5 kW/h of power per vessel serving dedusters of a 2,200 m/sup 2/ rotary brown coal dryer.
In the field of Living Probabilistic Safety Assessment (LPSA) the reliability data updating is an important factor. In risk analysis equipment failure data is needed to estimate the frequencies of events contributing to risk posed by a facility. Five years data of emergency diesel generator (EDG) of Daya Bay Nuclear PowerPlant (NPP) has been studied in this paper. The data updating process has been done by using two methods, i.e., the classical method and Bayesian method. The aim of using these methods is to calculate the operational failure rate (@l) and demand failure probability (p). The results show that the operational failure rate is 1.7E-3 per hour and the demand failure probability is 2.4E-2 demand per day for Daya Bay NPP. By comparing the results obtain from classical and Bayesi...
Calcium sulfate dihydrate which is co-produced in the scrubbing of waste gases from bituminous coal powerplants is employed in the underground road securing after recrystallization. Beta-sulfate semi hydrate is obtained from the dihydrate by recrystallisation and it is used as such or as a stiff mixture with additives as a stowing material. Particularly fly ash from coal combustion units, washery refuses and development rocks from coal mining or slags from the metallurgical industry can be used as additives. The compressive and the bending tensile strength of the stowing material can be adjusted by the water content in case beta sulfate semihydrate is used as such.
The moderate earthquake of magnitude 5.2 was occurred at the offshore Uljin on the 29 May 2004. The magnitude of the event is the largest one which is equal to that of the Sokrisan earthquake on the 16 September 1978 since the beginning of the instrumental recording by the Korean Metrological Administration (KMA) in 1978. The magnitude of the event was large enough to be felt in a wide area of the southern Korea. It did not affect the safety of the Uljin nuclear powerplant (NPP) site which is about 80 km away from the epicenter. In this article, we estimate source parameters of the event and evaluate preliminary seismic safety of the Uljin NPP site regarding the event as an empirical Green's function (EGF)
By the department Radio-ecology of the Laboratory for Radiation Research, in the period 1981 up to 1989 inclusive, the transfer has been studied, from soil to plant, of a number of important activation and fission products, originating in the nuclear-power production in nuclear powerplants. The purpose of this study was twofold: on the one side the quantification of this transfer for various agrarian systems and on the other side to find out in how far, after an accidental contamination, certain agriculture activities can influence essentially the transfer and subsequently the radiation burden for the population. Emphasis lay, the last years, in particular upon this second aspect. The results of this study form essential basic data for diffusion models for radioactive materials which, in turn, are important in estimating the effects of measures. (author). 6 refs.; 4 figs.
In Korea, a manufacturing process for the fabrication of CANDU 37-element fuel bundles was successfully developed between 1981 and 1986. At Korea Atomic Energy Research Institute (KAERI), more than 20,000 fuel bundles were produced up to May 1992, for use in Wolsung-1 power reactor. At the time of the conference, about 15,000 of these fuel bundles had been irradiated in Wolsung-1, and almost all of them had performed well. From 1995, the commercial fuel production program will be transferred to Korea Nuclear Fuel Company, which is building a plant with a capacity of 400 tons of uranium per year. So-called CANFLEX fuel, more appropriate to advanced fuel cycles, is being developed jointly by AECL and KAERI. The paper includes a listing of the current status of the Republic of Korea's nuclear powerplants, with planning projections up to the year 2006. 2 tabs.
In conventional powerplants trash-racks are provided at the intakes to protect the turbines. In pumped storage plants, the draft tube or tailrace must also have trash-racks to protect the units while pumping. Because the loads believed to cause many failures of trash-racks are dynamic in nature, it is important to understand the dynamic characteristics of trash-racks structures in general and a single rack in particular. The classical added-mass solution structure-fluid dynamic interaction is known as an approximate solution procedure. An accurate added-mass approach mixed with implementation in finite element framework is proposed. In this proposal, experimental conclusions, supported by theory, led to presentation of more accurate results in vibration of trash-racks. This numerical solution as a powerful method to solve such a complex problem can be employed to carry out dynamic characteristics of ...
The Level 1 probabilistic safety assessment (PSA) for Wolsung(WS) 2/3/4 nuclear powerplant (NPPs) in design stage is performed using the methodologies being equivalent to PWR PSA. Accident sequence evaluation program (ASEP) human reliability analysis (HRA) procedure and technique for human error rate prediction (THERR) are used in HRA of WS 2/3/4 NPPs PSA. The= purpose of this paper is to introduce the procedure and methodology of HRA in WS 2/3/4 NPPs PSA. Also, this paper describes the interim results of importance analysis for human actions modeled in WS 2/3/4 PSA and the findings and recommendations of administrative control of secondary control area from the view of human factors. (Author) 10 refs., 2 tabs.
The Level 1 probabilistic safety assessment (PSA) for Wolsong(WS) 2/3/4 nuclear powerplant(NPPs) in design stage is performed using the methodologies being equivalent to PWR PSA. Accident sequence evaluation program (ASEF) human reliability analysis (HRA) procedure and technique for human error rate prediction (THERP) are used in HRA of WS 2/3/4 NPPs PSA. The purpose of this paper is to introduce the procedure and methodology of HRA in WS 2/3/4 NPPs PSA. Also, this paper describes the interim results of importance analysis for human actions modeled in WS 2/3/4 PSA and the findings and recommendations of administrative control of secondary control area from the view of human factors.
The Heat Cycle Research Program, which is conducted for the Department of Energy, has as its objective the development of the technology for effecting the improved utilization of moderate temperature geothermal resources. The current testing involves the investigation of binary power cycle performance utilizing mixtures of non-adjacent hydrocarbons as the working fluids, with supercritical vaporization and in-tube condensation of the working fluid. The utilization of these concepts verified here will improve the net geofluid effectiveness (net watt hours plant output per pound of geofluid) about 20% over that of a conventional binary powerplant. The major effect in this improvement is the ability to achieve integral, countercurrent condensation. Results are presented for the recent testing including those tests examining the performance of the countercurrent condenser at different tube inclinations and ...
The Electric Power Monthly is prepared by the Survey Management Division; Office of Coal, Nuclear, Electric and Alternate Fuels, Energy Information Administration (EIA), Department of Energy. This publication provides monthly statistics at the national, Census division, and State levels for net generation, fuel consumption, fuel stocks, quantity and quality of fuel, cost of fuel, electricity sales, revenue, and average revenue per kilowatthour of electricity sold. Data on net generation, fuel consumption, fuel stocks, quantity and cost of fuel are also displayed for the North American Electric Reliability Council (NERC) regions. Additionally, statistics by company and plant are published in the EPM on capability of new plants, new generation, fuel consumption, fuel stocks, quantity and quality of fuel, and cost of fuel.
Steam generator tubes in nuclear powerplants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostic system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of these items.
A decontamination washer for working dresses using liquid and supercritical carbon dioxide were designed and manufactured. The size of reactor for decontamination and solidification is about 16 liter. The system is a closed one with recycling ability of carbon dioxide. The efficiency of recycling of carbon dioxide and that of separation of solutes in carbon dioxide were checked. They met all the design goals. A remote control system of the carbon dioxide flow was set in a control panel. The manufactured decontamination washer was brought to Wolsung nuclear powerplants, and installed to check the efficiency of decontamination and the feasibility of usage in nuclear powerplants. The elimination of radioactive oil from the contaminated dresses were very high. However, the decontamination factor was lower than the design goal value. It's due to the low removal rate of radioactive particles ...
Concentrations of {sup 239+240} Pu and {sup 137} Cs were measured for vertical direction and horizontal direction in seawater collected at 21 locations on the 8 directions near Wolsung nuclear powerplant. The inventories of {sup 239+240} Pu and {sup 137} Cs were calculated in seawater column. The concentrations of {sup 239+240} Pu and {sup 137} Cs were in seawater in the range of 8-36 {mu}Bq/L, 2.4-4.5 mBq/L, respectively. The {sup 239+240} Pu concentration increased with depth, however, the {sup 137} Cs concentrations not greatly changed with depth above thermocline.
Concentrations of "2"3"9"+"2"4"0 Pu and "1"3"7 Cs were measured for vertical direction and horizontal direction in seawater collected at 21 locations on the 8 directions near Wolsung nuclear powerplant. The inventories of "2"3"9"+"2"4"0 Pu and "1"3"7 Cs were calculated in seawater column. The concentrations of "2"3"9"+"2"4"0 Pu and "1"3"7 Cs were in seawater in the range of 8-36 #mu#Bq/L, 2.4-4.5 mBq/L, respectively. The "2"3"9"+"2"4"0 Pu concentration increased with depth, however, the "1"3"7 Cs concentrations not greatly changed with depth above thermocline.
This paper presents results about the characterisation of the biomass fly ashes sourced from a thermal powerplant and from a co-generation powerplant located in Portugal, and the study of new cement formulations incorporated with the biomass fly ashes. The study includes a comparative analysis of the phase formation, setting and mechanical behaviour of the new cement-fly ash formulations based on these biomass fly ashes. Techniques such as X-ray diffraction (XRD), X-ray fluorescence spectroscopy (XRF), thermal gravimetric and differential thermal analysis (TG/DTA), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and environmental scanning electron spectroscopy (ESEM) were used to determine the structure and composition of the formulations. Fly ash F1 from the t...
The benchmark calculations have been performed for MCNP-4B code using the measurement data of Wolsong nuclear powerplant 2. In this study, the benchmark calculations have been performed for the criticality, boron worth, reactivity device worth, reactivity coefficient, and flux scan. Cross-section libraries were newly generated from ENDF/B-VI release 3 through NJOY97.114 data processing system and a three-dimensional full core model was developed for MCNP calculation. The simulation results have shown that the criticality is estimated within 4 mkn and the estimated reactivity worth of the control devices are generally consistent with the measurement data. In certain cases, the simulation results have shown large discrepancies against the measurement data, which will be sturdied further in the near future.
A review of tests on earthquake-resistant reinforced concrete structural walls is presented. Laboratory tests of isolated walls and construction joints are discussed. Where appropriate, design recommendations are given. The review indicates only few experimental data are available for short walls which are directly applicable to nuclear powerplant design. In particular, tests of short rectangular walls subjected to load reversals are needed. Tests are also needed to determine the damping and frequency characteristics of cracked short walls. Analytical and experimental results should be correlated so that the hysteretic response observed in tests can be realistically related to the analytical response 'demand' of nuclear powerplant structures. (Auth.).
This paper summarizes the findings from an exploratory definition of a usage strategy for multiple control centre wall displays in CANDU nuclear powerplants. Wall displays are defined as large sized, vertically oriented display surfaces that may be positioned in various locations about a control room to support user information needs. The paper begins by discussing the need for a usage strategy for all control room information resources, and then reviews the history in wall display implementation and usage in nuclear powerplant control rooms. The balance of the paper discusses the approach used in characterization and review of control room task information needs and definition of a wall display usage strategy. The paper concludes by outlining some of the possible impacts on future control room design and operations that the introduction of wall displays may imply. (author)
In order to maintain a safe operation and availability of generating facilities, qualitative and quantitative assessment of piping vibration was performed vibration sources and damages of piping support was identified on the second piping system of Wolsung nuclear powerplant unit 1 .Inspected piping supports and structures in both hot and cold condition .Established evaluation procedures of piping vibration .Performed the static analysis of 2 nd piping system .Established optimal vibration reducing method .The measured vibration level after installing rigid supports and energy absorbing type restraint was reduced about 7 times in velocity unit (author). 24 refs., 95 figs.
The purpose of this study is to investigate on the experimental verification analysis for the pipe whip problems and to obtain the quantitative evaluation technologies for the design technique of pipe whip restraints. These will contribute to the advance of nuclear regulatory technologies and enhance nuclear powerplant safety. This study presents the experimental and transient analytical results of pipe whip tests using the 4', 6' diameter pipe and U-shaped restraints. In the tests, the effects of the overhang length, clearance, impact height on the pipe whip behavior of the pipe-restraints were investigated. The transient impact analysis of the pipe-restraint system was conducted by the finite element program ABAQUS. The applicability of the ABAQUS program to the pipe whip analysis is made clear through this analysis.
This final report for the Swiss Federal Office of Energy (SFOE) describes the 23.5 kW photovoltaic installation on the Customs House in Kreuzlingen, Switzerland. The objective of the 'Zollhof' photovoltaic solar powerplant is to provide the local population with a 'hands-on' solar cell experience, that, according to the authors, should lead to better understanding of renewable energy technology. The commissioning and initial operation of the installation is commented on, as are the above-average production figures of the plant. The power produced is sold by the local utility to its customers as electricity from renewable resources.