WorldWideScience
1

On the performances of Intensity Modulated Protons, RapidArc and Helical Tomotherapy for selected paediatric cases  

UK PubMed Central (United Kingdom)

BackgroundTo evaluate the performance of three different advanced treatment techniques on a group of complex paediatric cancer cases.MethodsCT...Full Text Available

2

Computerized tomography and head growth curve infantile macrocephaly with normal psychomotor development  

Energy Technology Data Exchange (ETDEWEB)

Macrocephaly was defined as a head measuring larger than 98th percentile. We have evaluated CT findings and head growth curves in 25 infants with large heads. Ten (40%) of 25 infants with large heads were normal developmentally and neurologically. Five (20%) of those were mentally retarded. The other 10 infants (40%) included hydrocephalus (4 cases), malformation syndrome (3 cases), brain tumor (1 case), metabolic disorder (1 case) and degenerative disorder (1 case). Their head growth curves were typed as (I), (II) and (III): Type (I) (excessive head growth curve to 2 SDs above normal); Type (II) (head growth curve gradually approached to 2 SDs above normal); Type (III) (head growth curve parallel to 2 SDs above normal). Ten of macrocephaly with normal psychomotor development were studied clinically ...

1982-01-01

3

Follow-up and diagnosis of recurrences after radio-chemotherapy of malignant head and neck tumors  

International Nuclear Information System (INIS)

339 CT und 95 MRT examinations in 210 partients were evaluated retrospectively to determine the value of CT and MRT for follow-up of head and neck tumors and for diagnosing recurrences. Semi-quantitative evaluation of tumor extent during and after radiotherapy showed advantages for MRT since changes induced by treatment, particularly oedema, produced less contrast loss in the images. CT had a sensitivity of 81% for the recognition of recurrences; this was 92% for MRT. Specificity for CT was 76% and for MRT 86%. Concerning the reliability of individual diagnostic criteria, space occupying lesions were the most valuable in CT diagnosis. For MRT, space occupying lesions and infiltration into neighbouring structures were of equal value. Because of differences in the nature of the signals, MRT proved better than CT in characterising recurrent ...

4

Effective dose estimation in whole-body multislice CT in paediatric trauma patients  

Energy Technology Data Exchange (ETDEWEB)

The number of multislice CT (MSCT) scans performed in polytraumatized children has increased rapidly. There is growing concern regarding the radiation dose in MSCT and its long-term consequences, especially in children. To determine the effective dose to polytraumatized children who undergo whole-body MSCT. A total of 51 traumatized children aged 0-16 years underwent a polytrauma protocol CT scan between November 2004 and August 2006 at our institution. The effective dose was calculated retrospectively by a computer program (CT-Expo 1.5, Hannover, Germany). The mean effective dose was 20.8 mSv (range 8.6-48.9 mSv, SD{+-}7.9 mSv). There was no statistically significant difference in the effective dose between male and female patients. Whole-body MSCT is a superior diagnostic tool in polytraumatized children with 20.8 mSv per patient being a justified mean effective dose. In a potentially life-threatening situation whole-body ...

2009-03-15

5

Computed tomography of the acetabular fractures  

Energy Technology Data Exchange (ETDEWEB)

In a retrospective study of 21 patients, in whom the acetabular fractures were suspected on initial radiographs, we compared and analysed the computed tomographic findings and plain radiographic findings. The results were as follow: 1. In patients with multiple trauma, no further change in position was required during CT examinations. 2. CT showed intraarticular loose bodies, which were invisible on plain radiographs. 3. CT was useful in detecting the fractures of acetabular rims, medial wall of acetabulum, and femoral head. 4. CT permitted better evaluation of shape, extent, and degree of separation of fracture fragments. 5. CT was helpful in detecting the associated fractures and soft tissue injuries. 6. CT also demonstrated the adequacy of reduction, the position of metallic fixation devices, and the presence or absence of remaining ...

1986-04-15

7

Reevaluation of the 'Falx sign'  

Energy Technology Data Exchange (ETDEWEB)

Visualization of falx cerebral on non-enhanced computer tomography (CT) of children with severe head injuries (the falx sign) has been regarded as an evidence of subarachnoid hemorrhage. On the contrary, other authors have reported reverse results. To evaluate clinical significance of the falx sign, authors studied frequency of visualization and CT number of falx cerebri and dural sinuses in 65 children with head injury and 65 children without head injury examined by cranial computer tomography at the Department of radiology, St Paul's Hospital, Catholic Medical College from March to September, 1981. All patients with head trauma were studied within 1 week of the traumatic event. Visualization of falx cerebri was observed at slice in the region of lateral ventricle and slice near to vertex respectively. On the slice in the region of lateral ventricle, ...

1982-06-15

8

Traumatic extremity arterial injury in children: Epidemiology, diagnostics, treatment and prognostic value of Mangled Extremity Severity Score  

UK PubMed Central (United Kingdom)

BackgroundTraumatic paediatric arterial injuries are a great challenge due to low incidence and specific characteristics of paediatric anatomy and physiology. The aim of the present...Full Text Available

9

Paediatric Palliative Care: Theory to Practice  

UK PubMed Central (United Kingdom)

Paediatric palliative care is a holistic approach aimed at addressing the complex issues related to the care of children and families facing chronic life limiting illnesses. The needs of children are...Full Text Available

2011-01-01

10

Investigation into paediatric bilirubin analyses in Australia and New Zealand.  

UK PubMed Central (United Kingdom)

A small regional survey of direct spectrophotometric methods and a larger Australian and New Zealand survey of paediatric bilirubin analyses are described. The overall performance of both groups was...Full Text Available

1982-01-01

11

Anatomical changes after radical surgery and reconstruction with pedunculated or revascularized flaps in advanced head and neck cancer: CT and MR features; Modificazioni anatomiche dopo chirurgia radicale e ricostruzione con lembi peduncolati o rivascolarizzati nei tumori cervico-facciali negli stadi avanzati: Aspetti con Tomografia Computerizzata e Risonanza Magnetica  

Energy Technology Data Exchange (ETDEWEB)

January, 1992, to October, 1995, sixty-four patients with advanced head and neck cancer underwent head and neck reconstructive surgery using myocutaneous or revascularized flaps; in the same period, all patients were consecutively examined with CT and MRI. Myocutaneous flaps were used in 26 patients: 12 flaps were tubular and 14 linear. Revascularized flaps were used in 38 patients: to repair a large defect in 26 patients (14 latissimus dorsi flaps and 12 temporal muscle flaps) and to repair an oral damage in 12 patients (5 revascularized radial and 7 jejunal flaps). CT and MR images of myocutaneous flaps showed the flaps as fatty areas, repairing large surgical defects, hypodense at CT and hyperintense at MRI, with no post-contrast enhancement. The appearance of revascularized flaps at CT and MRI depends on the characteristics of the structure used to repair ...

1997-04-01

12

Anatomical changes after radical surgery and reconstruction with pedunculated or revascularized flaps in advanced head and neck cancer: CT and MR features  

International Nuclear Information System (INIS)

January, 1992, to October, 1995, sixty-four patients with advanced head and neck cancer underwent head and neck reconstructive surgery using myocutaneous or revascularized flaps; in the same period, all patients were consecutively examined with CT and MRI. Myocutaneous flaps were used in 26 patients: 12 flaps were tubular and 14 linear. Revascularized flaps were used in 38 patients: to repair a large defect in 26 patients (14 latissimus dorsi flaps and 12 temporal muscle flaps) and to repair an oral damage in 12 patients (5 revascularized radial and 7 jejunal flaps). CT and MR images of myocutaneous flaps showed the flaps as fatty areas, repairing large surgical defects, hypodense at CT and hyperintense at MRI, with no post-contrast enhancement. The appearance of revascularized flaps at CT and MRI depends on the characteristics of the structure used to repair ...

1997-01-01

13

Is energy imparted a good measure of the radiation risk associated with CT examinations  

International Nuclear Information System (INIS)

The dose distribution in a Rando phantom has been measured for typical EMI 5005 CT scans of the head, chest, abdomen and pelvis. These dose distributions have been used to generate quantitative estimates of the somatic and genetic radiation risks associated with these CT examinations and also to measure the total energy imparted during each scan. A comparison has been made between the radiation risk estimates and the energy imparted measurements. The energy imparted measurements are not a good indicator of the somatic and/or genetic risks when one type of CT scan is compared with another. However, for a given type of scan, the energy imparted may be a reasonable indicator of the relative somatic risks associated with different CT examinations. Considerable care should be taken when interpreting and using any measured value of energy imparted in a radiological examination since ...

14

Multi-modality imaging of uveal melanomas using combined PET/CT, high-resolution PET and MR imaging  

Energy Technology Data Exchange (ETDEWEB)

We investigated the efficacy of combined FDG-PET/CT imaging for the diagnosis of small-size uveal melanomas and the feasibility of combining separate, high-resolution (HR) FDG-PET with MRI for its improved localization and detection. Patients, methods: 3 patients with small-size uveal melanomas (0.2-1.5 ml) were imaged on a combined whole-body PET/CT, a HR brain-PET, and a 1.5 T MRI. Static, contrast-enhanced FDG-PET/CT imaging was performed of head and torso with CT contrast enhancement. HR PET imaging was performed in dynamic mode 0-180 min post-injection of FDG. MRI imaging was performed using a high-resolution small-loop-coil placed over the eye in question with T2-3D-TSE and T1-3D-SE with 18 ml Gd-contrast. Patients had their eyes shaded during the scans. Lesion visibility on high-resolution FDGPET images was graded for confidence: 1: none, 2: suggestive, 3: clear. Mean tumour ...

2008-07-01

15

Application of low-dose radiation protocols in survey CT scans  

International Nuclear Information System (INIS)

Objective: To characterize the protocols with low-dose radiation in survey CT scans for localization. Methods: Eighty standard adult patients, head and body phantoms were recruited. Default protocols provided by operator's manual setting were that all the tube voltage for head, chest, abdomen and lumbar was 120 kV; the tube currents were 20,10,20 and 40 mA, respectively. Values of kV and mA in the low-dose experiments were optimized according to the device options. For chest and abdomen, the tube position were compared between default (0 degree) and 180 degree. Phantoms were scanned with above protocols, and the radiation doses were measured respectively. Paired t-test were used for comparisons of standard deviation in CT value, noise and exposure surface dose (ESD) between group with default protocols and group with optimized protocols. Results: The optimized protocols in low-dose ...

2009-08-01

16

A three-dimensional display system for brain CT images  

International Nuclear Information System (INIS)

Commercially available CT devices reconstruct cross-sectional slices of the human body. A sequence of such abutting cross-sectional slices can be, and usually is, used to obtain information about the region of the head, which requires several slices to cover it. However, there are situations for which such asequence of displays is far from optimal - for example, when one would like to see the anatomic relationship between two features appearing in different slices or the shape of a particular region or tumor. The Computer Aided Three-Dimensional Reconstruction and Imaging System (CATRIS), developed at our university, can build up a three-dimensional image from a series of CT cross-sections and can display its stereoscopic image on a three-dimensional graphic display system, thus providing helpful information for clinical use in recognizing the anatomic relationship between two features appearing in different slices or the ...

17

Determinants of the drug utilization profile in the paediatric population in Italy's Lombardy Region  

UK PubMed Central (United Kingdom)

AIMSTo evaluate the intraregional differences in drug prescribing to children and adolescents.METHODSPrescriptions reimbursed...Full Text Available

2009-05-01

18

Quantitative CT assessment of proximal femoral bone density. An experimental study concerning its correlation to breaking load for femoral neck fractures  

International Nuclear Information System (INIS)

Purpose: In an experimental study, the correlation between the trabecular bone density of the different regions of the proximal femur and the fracture load in the setting of femoral neck fractures was examined. Methods: The bone mineral density 41 random proximal human femora was estimated by single-energy quanitative CT (SE-QCT). The trabecular bone density was measured at the greatest possible extracortical volume at midcapital, midneck and intertrochanteric level and in the 1 cm"3 volumes of the centres of these regions in a standardised 10 mm thick slice in the middle of the femoral neck axis (in mg/ml Ca-hydroxyl apatite). The proximal femora were then isolated and mounted on a compression/bending device under two-legged stand conditions and loaded up to the point when a femoral neck fracture occurred. Results: Statistical analysis revealed a linear correlation between the trabecular bone density and the fracture load for the greater regions, with the highest ...

19

Computed tomography whole body imaging in multi-trauma: 7 years experience  

International Nuclear Information System (INIS)

AIM: To assess the impact of the introduction of a computed tomography (CT) imaging protocol for multi-trauma patients on the workload, overall diagnostic yield, and effect on detection of cervical spine injury and pneumothorax. METHOD: Between February 1997 and April 2004, all patients presenting acutely to the Emergency Department (ED) with haemodynamically stable trauma (Abbreviated Injury Scale 3 or more) involving more than two body systems were imaged with a comprehensive pre-set helical CT protocol (including non-contrast head, cervical spine: cranio-cervical and cervico-thoracic junctions; and oral and intravenous contrast-enhanced thoracic, abdomen and pelvis) after initial triage and a standard trauma series of radiographs (chest, lateral C-spine and pelvis). Diagnosis of cervical spine fracture and pneumothorax was noted before and after the CT protocol was carried out and findings from all ...

2006-04-01

20

The role of 3D Helical CT in the reconstructive treatment of maxillofacial cancers  

International Nuclear Information System (INIS)

Purpose of this work is to investigate the role of Helical CT and the usefulness of three-dimensional (3D) imaging for pre-operative planning and follow-up of reconstructive maxillofacial surgery with alloplastic material in neoplastic disease involving this region. From 1996 to 1999 eleven patients were examined with Helical CT and 3D images for planning of maxillofacial plastic and reconstructive surgery for advanced cancer of this anatomically complex region. A 3D-modulated titanium mesh (100%) or micro nets was used to rebuild the anterior surface of maxillary bone and the orbital floor. The mesh was cut to the appropriate size and shape and curved where necessary. Within the residual sinusal cavity a siliconed filling was used surmounting an acrylic prosthesis with dental arch to rebuild the palate. A rehydrated bovine pericardium was affixed and moduled on the borders in two cases only. Three-dimensionally reconstructed ...

2000-12-01

21

The usefulness of CBF brain SPECT in forensic medicine: the civil law codes cases. A description of four cases  

International Nuclear Information System (INIS)

The aim of this report was to assess the usefulness of cerebral blood flow (CBF) scanning utilising the SPECT technique in forensic medicine cases in the area of civil law cases. CBF SPECT scanning was performed in four patients utilising "9"9"mTc-ECD and a triple-head gammacamera. In the analysis both the asymmetry index and cerebellar normalisation were applied. Reference values were obtained by studying 30 healthy volunteers. In those cases CBF SPECT scanning played an important role in forensic argument. It influenced the sentence and the amount of financial compensation. CBF SPECT scanning may provide valuable information in forensic medicine argument in civil law cases, but only when taken together with psychometric tests and other neuroimaging methods (CT, MRI). The value of CBF SPECT scanning alone may be limited in judicial proceedings. (author)

22

Mapping of local cerebral blood flow with stable xenon-enhanced CT and the curve-fitting method of analysis  

Energy Technology Data Exchange (ETDEWEB)

A noninvasive method is described for estimating local cerebral blood flow (LCBF) and local partition coefficients by means of computed tomographic scanning during inhalation of 30% stable xenon gas in oxygen. Time-dependent xenon concentrations in arterial blood and brain tissue during the wash-in and washout phases are used to calculate partition coefficients and LCBF values by means of a least-squares curve-fitting analysis. Control values for partition coefficient and LCBF obtained from control subjects with minor head trauma in the chronic stage were compatible with those in several past reports, and reproducibility was satisfactory. The theoretic grounds underlying this new method of curve-fitting analysis are discussed.

1988-07-01

23

Mapping of local cerebral blood flow with stable xenon-enhanced CT and the curve-fitting method of analysis  

International Nuclear Information System (INIS)

A noninvasive method is described for estimating local cerebral blood flow (LCBF) and local partition coefficients by means of computed tomographic scanning during inhalation of 30% stable xenon gas in oxygen. Time-dependent xenon concentrations in arterial blood and brain tissue during the wash-in and washout phases are used to calculate partition coefficients and LCBF values by means of a least-squares curve-fitting analysis. Control values for partition coefficient and LCBF obtained from control subjects with minor head trauma in the chronic stage were compatible with those in several past reports, and reproducibility was satisfactory. The theoretic grounds underlying this new method of curve-fitting analysis are discussed.

24

Functional MRI of the pharynx in obstructive sleep apnea (OSA) with rapid 2-D flash sequences  

International Nuclear Information System (INIS)

Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager ('Vision', Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, functional fiberoptic nasopharyngoscopy and polysomnography. A ...

25

Comparative evaluation of similarity measures for the rigid registration of multi-modal head images  

Energy Technology Data Exchange (ETDEWEB)

Image registrations that are based on similarity measures simply adjust the parameters of an appropriate spatial transformation model until the similarity measure reaches an optimum. The numerous similarity measures that have been proposed in the past are differently sensitive to imaging modality, image content and differences in the image content, selection of the floating and target image, partial image overlap, etc. In this paper, we evaluate and compare 12 similarity measures for the rigid registration. To study the impact of different imaging modalities on the behavior of similarity measures, we have used 16 CT/MR and 6 PET/MR image pairs with known 'gold standard' registrations. The results for the PET/MR registration and for the registration of CT to both rectified and unrectified MR images indicate that mutual information, normalized mutual information and the entropy correlation coefficient are the most accurate ...

2007-09-21

26

Comparison of high resolution whole-body MRI using parallel imaging and PET-CT. First experiences with a 32-channel MRI system  

International Nuclear Information System (INIS)

To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI scanner (Magnetom Avanto, Siemens Medical Solutions) with a total field of view of ...

27

Urinary tract infection in children.  

UK PubMed Central (United Kingdom)

During 1968-77, 572 consecutive children with one or more positive urine cultures who were referred by their family doctors to one paediatric surgical outpatient clinic were investigated and prospectively...Full Text Available

1984-08-04

28

The Role of Placental Homeobox Genes in Human Fetal Growth Restriction  

UK PubMed Central (United Kingdom)

Fetal growth restriction (FGR) is an adverse pregnancy outcome associated with significant perinatal and paediatric morbidity and mortality, and an increased risk of chronic disease later in adult life....Full Text Available

2011-01-01

29

Nutrient needs and feeding of premature infants. Nutrition Committee, Canadian Paediatric Society.  

UK PubMed Central (United Kingdom)

OBJECTIVE: To recommend appropriate intake of nutrients, food sources and feeding practices for premature infants. OPTIONS: Unfortified milk from the premature infant's own mother, fortified milk from...Full Text Available

1995-06-01

30

Quantitative CT assessment of proximal femoral bone density. An experimental study concerning its correlation to breaking load for femoral neck fractures; Quantitative CT des proximalen Femurs. Experimentelle Untersuchungen zur Korrelation mit der Bruchlast bei Schenkelhalsfrakturen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: In an experimental study, the correlation between the trabecular bone density of the different regions of the proximal femur and the fracture load in the setting of femoral neck fractures was examined. Methods: The bone mineral density 41 random proximal human femora was estimated by single-energy quanitative CT (SE-QCT). The trabecular bone density was measured at the greatest possible extracortical volume at midcapital, midneck and intertrochanteric level and in the 1 cm{sup 3} volumes of the centres of these regions in a standardised 10 mm thick slice in the middle of the femoral neck axis (in mg/ml Ca-hydroxyl apatite). The proximal femora were then isolated and mounted on a compression/bending device under two-legged stand conditions and loaded up to the point when a femoral neck fracture occurred. Results: Statistical analysis revealed a linear correlation between the trabecular bone density and the fracture load for the greater regions, with the ...

1997-12-01

31

10% low density corn-oil emulsion oral contrast agent for abdominal computed tomography  

Energy Technology Data Exchange (ETDEWEB)

CT of the gastrointestinal tract is commonly performed after administration of a high-density diluted iodinated oral contrast material. However, because if inadequate mixing of the contrast material with the gastrointestinal contents, pseudotumor and poor mucosal visualization are frequently shown on abdominal CT. To overcome these problem, 10% corn oil emulsion (COE) is tested as an alternative oral contrast agent in 40 patients. We analyse patients tolerance, gastric mucosal visualization and discrimination of pancreas from the duodenal C-loop to 10% COE in 40 patients compared with those obtained from 35 patients, who was received high-density diluted iodinated oral contrast agent (gastrografin). The results are as follows : 1. Patients' tolerance to 10% COE is similar to that to conventional oral contrast agent. 2. Image of the gastric mucosa from patients receiving 10% COE is superior to that receiving oral contrast agent. 3. The ...

1990-10-15

32

10% low density corn-oil emulsion oral contrast agent for abdominal computed tomography  

International Nuclear Information System (INIS)

CT of the gastrointestinal tract is commonly performed after administration of a high-density diluted iodinated oral contrast material. However, because if inadequate mixing of the contrast material with the gastrointestinal contents, pseudotumor and poor mucosal visualization are frequently shown on abdominal CT. To overcome these problem, 10% corn oil emulsion (COE) is tested as an alternative oral contrast agent in 40 patients. We analyse patients tolerance, gastric mucosal visualization and discrimination of pancreas from the duodenal C-loop to 10% COE in 40 patients compared with those obtained from 35 patients, who was received high-density diluted iodinated oral contrast agent (gastrografin). The results are as follows : 1. Patients' tolerance to 10% COE is similar to that to conventional oral contrast agent. 2. Image of the gastric mucosa from patients receiving 10% COE is superior to that receiving oral contrast agent. 3. The ...

1990-10-01

33

Feature-based rectal contour propagation from planning CT to cone beam CT  

UK PubMed Central (United Kingdom)

The purpose of this work is to develop a novel feature-based registration strategy to automatically map the rectal contours from planning computed tomography (CT) (pCT) to cone beam CT (CBCT). The rectal...Full Text Available

2008-10-01

35

Gunshot wounds to the head. Correlations between CT and clinical findings, neurosurgical treatment and long-term sequels; Traumi cranio-encefalici da proiettile: correlazione tra tomografia computerizzata, clinica, trattamento neurochirurgico e sequele a distanza  

Energy Technology Data Exchange (ETDEWEB)

With the aim of demonstrating the usefulness of computerised tomography (CT) findings in the planning of brain neurosurgery in gunshot victims, for prompt and successful treatment, 30 patients with brain gunshot wounds were examined with CT over 5 years. The mortality rate of firearm wounds of the skull base was 34% higher than that of the hemisphere; this is due to carotid hemorrhage and midbrain damage. Such traumas require emergency radiological diagnosis and neurosurgical treatment because of their severity and early irreversible complications. Complex operations and skilled surgeons may prevent disabling postoperative sequels. CT findings are indispensable and must be correctly interpreted. The radiologist and the neurosurgeon must collaborate closely and both must consider several diagnostic factors affecting surgical planning. [Italian] Scopo dello studio e' stato quello di dimostrare ...

2000-03-01

36

Paediatric radiography - the avoidance of late radiation damage to the growing hip  

Energy Technology Data Exchange (ETDEWEB)

Epiphyseal plates of growing bones are sensitive to ionizing radiation and this poses problems for the paediatric radiotherapist. In this case report we describe a child in whom electron beam therapy to the groin delivered only low dose radiation to the proximal hip epiphyses - 130 cGy fractionated over 5 weeks - but who suffered late maldevelopment. We explore the success of various radiotherapy techniques in minimizing the dose to the hip epiphyses in four other children. The appropriate positioning of the limb, the choice of treatment modality and, where possible, individual shielding blocks are considered and their effect on the dose to the hip estimated. Absorbed doses of radiation delivered to the midpoint of the proximal femoral epiphyses have been retrospectively determined. (author).

1993-04-01

37

Renal artery stenosis after radiotherapy for Ewing's sarcoma  

International Nuclear Information System (INIS)

Background: the fact that therapeutic irradiation can induce significant stenosis in the arteries of the head, neck, and chest, as welt as in the aorta and the iliac arteries, is familiar in daily practice and well documented in the literature. By contrast, radiation-induced renal artery stenosis seems to be a less widely known complication. Patients and methods: the sudden onset of medically refractory arterial hypertension and coma in a 27-year-old man is reported, who had been treated at age 20 with chemotherapy and radiotherapy for Ewing's sarcoma in the lumbar region. This treatment had been performed at the hospital of Sion, Switzerland in 2001. Also, the relevant literature from 1965 to 2007 is reviewed to underscore various aspects of this problem and to demonstrate the clinical relevance of renal artery stenosis as a potential long-term sequela of radiotherapy. Conclusion: radiation-induced renal artery stenosis has only rarely been described in the ...

2008-09-01

38

The application of 64 multidetector CT angiography in the evaluation of carotid stenosis and follow-up of carotid endarterectomy and percutaneous transluminal stenting  

International Nuclear Information System (INIS)

Objective: To evaluate the diagnostic value of 64 multidetector-row CT angiography for internal carotid artery (ICA) stenosis and the application in the follow-up of carotid endarterectomy and percutaneous transluminal stenting. Methods: Forty transient ischemic attack (TIA) patients with interpretable CTA and DSA of the cervical carotid arteries were selected from May 2005 to December 2005. This yielded a total of 80 vessels. The CTA curved planar reformations (CPR) and DSA images referenced to the distal cervical internal carotid were graded by two senior neuroradiologists blindly, according to the North American Symptomatic Carotid Endarterectomy Trial (NASCET) guidelines. The paired-t test was used to verify the statistical significant difference between pre-operating and post-operating of carotid endarterectomy or percutaneous transluminal stenting in measuring the vascular diameter and area of cross section using CTA. Results: When the 70% stenosis was used ...

2006-09-01

39

Utility of CT in the diagnosis of psoitis  

International Nuclear Information System (INIS)

A 65-year-old woman who was diagnosed as having psoitis by CT findings, which disclosed non-symmetrical dilation of the psoas muscle and gaseous image. Pus from the psoas muscle seen at surgery corresponded to CT findings. Preoperative CT examination was useful in the establishment of diagnosis. (Namekawa, K.).

1984-01-01

41

MULTIMODALITY IMAGING: BEYOND PET/CT AND SPECT/CT  

UK PubMed Central (United Kingdom)

Multimodality imaging with PET/CT and SPECT/CT has become commonplace in clinical practice and in preclinical and basic medical research. Do other combinations of imaging modalities have a similar...Full Text Available

2009-09-01

43

Enhanced CT and CT virtual endoscopy in diagnosis of heterotopic pancreas  

UK PubMed Central (United Kingdom)

AIM: To improve the diagnosis of heterotopic pancreas by the use of contrast-enhanced computed tomography (CT) imaging and CT virtual endoscopy (CTVE).METHODS: A total of six patients with heterotopic...Full Text Available

2011-09-07

44

CT evaluation of acetabular fractures  

International Nuclear Information System (INIS)

The paper deals with sixteen cases of acetabular fractures studied with CT. After a short description of the normal CT findings, the different kind of fractures are reported. The usefulness of CT examination in evaluating acetabular fractures and their complications is confirmed both in conservative treatment and surgical approach.

1986-01-01

45

Radiation doses and somatic risk to patients during cardiac radiological procedures  

International Nuclear Information System (INIS)

The radiation dose to a series of adult and paediatric patients undergoing cardiac catheterisations and adults having percutaneous transluminal coronary angioplasty has been measured/determined directly using lithium fluoride thermoluminescent dosemeters and indirectly using an air ionisation chamber which indicated exposure-area product. Somatic and genetic risks are estimated from the dosimetry results. It is suggested that the magnitude of the radiation hazard is negligible compared with other clinical hazards associated with these procedures. (author).

1986-01-01

46

Iodine nutrition and risk of thyroid irradiation from nuclear accidents  

International Nuclear Information System (INIS)

The objectives of this paper are to discuss the following aspects of physiopathology of iodine nutrition related to thyroid irradiation by nuclear accidents: (1) The cycle of iodine in nature, the dietary sources of iodine and the recommended dietary allowances for iodine. (2) The anomalies of thyroid metabolism induced by iodine deficiency. The caricatural situation as seen in endemic goitre will be used as mode. (3) The specific paediatric aspects of adaptation to iodine deficiency. (4) The present status of iodine nutrition in Europe. (author).

47

Importance of computer tomography in paediatric diagnostics of abdominal and pelvic tumours  

Energy Technology Data Exchange (ETDEWEB)

In a joint study conducted by the University Clinic of Radiology, Graz, and the Medical University Clinic, Innsbruck, the results of computer tomography examinations of the abdomen and pelvis in 23 cases of tumours in children are discussed. In children computer tomography resents special difficulties on account of the very poorly developed fatty layers between the organs and the increased incidence of movement artifacts. The importance of computer tomography for the diagnosis of abdominal and pelvic tumours is discussed.

1980-03-01

48

Concepts of radiotherapy treatment planning  

International Nuclear Information System (INIS)

Full text: Radiotherapy treatment planning (RTP) relies heavily on medical imaging. Until recently, the most important planning tool was the treatment simulator. The kilovoltage radiographic capabilities in a treatment simulator enabled the boundaries of treatment fields to be visualized with respect to bony anatomic landmarks. Perhaps the most important advance in treatment planning in recent years is the ability to visualize the passage of the beams with respect to a more accurate geometrical representation of the tumor and other soft tissue structures. This 'virtual simulation' uses a computer-based representation of a patient to determine the extent of the disease and the location of radiation sensitive normal tissue. Computer tomographic (CT) imaging produces a high-resolution three-dimensional representation of anatomy that can be correlated with other image sets such as magnetic resonance images (MRI) of function. Positron emission tomographic (PET) imaging ...

2000-12-01

49

Automatic segmentation of thoracic and pelvic CT images for radiotherapy planning using implicit anatomic knowledge and organ-specific segmentation strategies  

Energy Technology Data Exchange (ETDEWEB)

Automatic segmentation of anatomical structures in medical images is a valuable tool for efficient computer-aided radiotherapy and surgery planning and an enabling technology for dynamic adaptive radiotherapy. This paper presents the design, algorithms and validation of new software for the automatic segmentation of CT images used for radiotherapy treatment planning. A coarse to fine approach is followed that consists of presegmentation, anatomic orientation and structure segmentation. No user input or a priori information about the image content is required. In presegmentation, the body outline, the bones and lung equivalent tissue are detected. Anatomic orientation recognizes the patient's position, orientation and gender and creates an elastic mapping of the slice positions to a reference scale. Structure segmentation is divided into localization, outlining and refinement, performed by procedures with implicit anatomic knowledge using standard image ...

2008-03-21

50

Underground reservoirs for high-head pumped-storage stations  

Science.gov (United States)

The advantages of using heads of around 1000 m in conjunction with underground location of the lower reservoirs for pumped storage plants are described, and the possible layouts, equipment, and construction methods are discussed.

1973-03-01

51

Coordination of the Eyes and Head during Visual Orienting  

UK PubMed Central (United Kingdom)

Changing the direction of the line of sight is essential for the visual exploration of our environment. When the head does not move, re-orientation of the visual axis is accomplished with high...Full Text Available

2008-10-01

52

Computed tomography of head in Clinic Pediatrics  

Energy Technology Data Exchange (ETDEWEB)

138 unselected head tomographies of children by computer are reported and analysed. The major aspect stressed by the authors is the excellent precision of this radiological technique.

1982-02-01

53

Comparison of high resolution whole-body MRI using parallel imaging and PET-CT. First experiences with a 32-channel MRI system; Hochaufloesendes Ganzkoerpertumorstaging unter Verwendung paralleler Bildgebung im Vergleich zur PET-CT. Erste Erfahrungen auf einem 32-Kanal-MRT-System  

Energy Technology Data Exchange (ETDEWEB)

To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI scanner (Magnetom Avanto, Siemens Medical Solutions) with a total field of view of ...

2004-09-01

54

Point/counterpoint: dose-related issues in cardiac CT imaging  

British Library Electronic Table of Contents (United Kingdom)

This manuscript reviews some of the more controversial dose-related issues in cardiac CT imaging. Discussion covers the relative merits of cardiac CT versus MR, advantages and concerns regarding gated versus nongated cardiac CT and advantages and concerns regarding the use of breast shields in girls undergoing cardiac CT imaging.

2011-01-01

55

A stochastic convolution/superposition method with isocenter sampling to evaluate intrafraction motion effects in IMRT  

International Nuclear Information System (INIS)

Current methods to calculate dose distributions with organ motion can be broadly classified as 'dose convolution' and 'fluence convolution' methods. In the former, a static dose distribution is convolved with the probability distribution function (PDF) that characterizes the motion. However, artifacts are produced near the surface and around inhomogeneities because the method assumes shift invariance. Fluence convolution avoids these artifacts by convolving the PDF with the incident fluence instead of the patient dose. In this paper we present an alternative method that improves the accuracy, generality as well as the speed of dose calculation with organ motion. The algorithm starts by sampling an isocenter point from a parametrically defined space curve corresponding to the patient-specific motion trajectory. Then a photon is sampled in the linac head and propagated through the three-dimensional (3-D) collimator structure corresponding to a particular MLC segment ...

2005-04-01

56

Serotypes and susceptibilities of paediatric clinical isolates of Streptococcus pneumoniae in Crete, Greece, before and after the heptavalent pneumococcal conjugate vaccine.  

Science.gov (United States)

All Streptococcus pneumoniae strains isolated from paediatric clinical samples at Heraklion University General Hospital in the 10-year period 2000-2009 were tested for serotype and susceptibility to antimicrobials. Among a total of 258 strains, 159 were isolated in the 5-year period 2000-2004, before the introduction of the heptavalent pneumococcal conjugate vaccine (PCV7), and 99 in the post-PCV7 5-year period 2005-2009. The prevalence of PCV7-included serotypes decreased in the post-PCV7 period (p?=?0.0002), but an increase was observed for serotypes 7F (p?=?0.002) and 19A (p?=?0.004). Pan-susceptibility rates and susceptibility to cotrimoxazole increased in the post-PCV7 period (p?=?0.01 and p?=?0.008, respectively), but serotype 19A emerged as a contributor to multi-resistance (p?=?0.007). PCV7 was followed by decreased S. pneumoniae resistance and prevalence of vaccine-related serotypes but increased prevalence of serotypes 7F and 19A. Continuing surveillance ...

2010-07-10

57

SLAP Tears  

Science.gov (United States)

... your upper arm bone (humerus), your shoulder blade (scapula), and your collarbone (clavicle). The head of your ...

61

Creation of the BioBank, Early Detection and Discovery Biomarkers  

Science.gov (United States)

Pancreatic Cancer; Head and Neck Cancer; Breast Cancer

2011-04-03

62

Quantification of lung surface area using computed tomography  

UK PubMed Central (United Kingdom)

ObjectiveTo refine the CT prediction of emphysema by comparing histology and CT for specific regions of lung. To incorporate both regional lung density measured by CT and cluster...Full Text Available

2010-01-01

63

Performance evaluation of an automatic anatomy segmentation algorithm on repeat or four-dimensional CT images using a deformable image registration method  

UK PubMed Central (United Kingdom)

PurposeAuto-propagation of anatomical region-of-interests (ROIs) from the planning CT to daily CT is an essential step in image-guided adaptive radiotherapy. The...Full Text Available

2008-09-01

64

Evaluation of tilted cone-beam CT orbits in the development of a dedicated hybrid mammotomograph  

UK PubMed Central (United Kingdom)

A compact dedicated 3D breast SPECT-CT (mammotomography) system is currently under development. In its initial prototype, the cone-beam CT sub-system is restricted to a fixed-tilt circular rotation...Full Text Available

2009-06-21

65

Dual Energy and Low kVp CT in the Abdomen  

UK PubMed Central (United Kingdom)

Low kVp settings provide high conspicuity of contrast materials at CT but may result in high image noise, particularly in larger patients. Material decomposition at dual energy CT can differentiate...Full Text Available

2009-07-01

66

Superselective intra-arterial DSA in patients with femoral head necrosis and femoral neck fracture. Superselektive intraarterielle DSA bei Hueftkopfnekrose und Schenkelhalsfraktur  

Energy Technology Data Exchange (ETDEWEB)

The prospective study includes 25 patients without pathology of the femoral head for the evaluation of the normal femoral head perfusion. In addition 34 patients with femoral head necrosis underwent i.a. DSA preoperatively before pedicled pelvic bone grafting. 15 patients after pelvic bone graft operation and 7 patients with medial femoral head fracture were also examined via superselective DSA. In cases with femoral head necrosis a rarefaction or interruption of the rami nutricii proximales, or an occlusion of the medial circumflex femoral artery were observed. Patients with medial femoral neck fracture showed an interruption of the rami nutricii proximales of the femoral head. Postoperative DSA - after pedicled pelvic bone graft - revealed a regular arterial graft perfusion in 82%. (orig.).

1991-06-01

67

Evaluation of femoral head perfusion by dynamic MRI  

International Nuclear Information System (INIS)

The purpose of this study was to evaluate the usefulness of dynamic MRI for femoral head perfusion. Objects were 64 femoral heads of 44 normal cases (20-95 years old), 10 cases (33-90 y) of femoral neck fracture and 8 cases (61-86 y) using steroid due to articular rheumatism, nephrosis and other diseases. Siemens 1.0 T Magneton Impact with body array coil was used for dynamic MRI by the fast low-angle shot 2D method for every 17 sec interval. Gd-DTPA was injected intravenously. ROI was defined in the center of femur head and of trochanter to monitor their values for the dynamic curve. Evaluation was done on the ratio of enhancement ratio (ER) in the head/trochanter and on the curve in both heads. In normal cases, the head ER was significantly lower in >60 years old cases. There was neither significant correlation between their ...

1998-05-01

68

Age-Related Long-Term Functional Results after Riboflavin UV A Corneal Cross-Linking.  

Science.gov (United States)

Purpose. To report a comparative prospective long-term functional analysis after Riboflavin UV A corneal cross-linking (CXL) in three different age groups of patients affected by progressive keratoconus (KC). Methods. Functional analysis comprised paediatric patients (?18 years) included 152 eyes (29.5%); intermediate group (19-26 years) 286 eyes (55.4%), and adults (?27 years) 78 eyes (15.1%). CXL was performed according to the Siena protocol by using the Vega CBM (Caporossi-Baiocchi-Mazzotta) X linker (CSO, Florence, Italy) at Siena University by the same authors. Pre- and post-op examinations included UCVA, BSCVA, corneal topography, and surface aberrometry (CSO Eye Top, Florence, Italy), at 48 months followup. Results. At 48 months followup paediatrics, intermediate, and adult patients showed a mean gain in UCVA of +0.2, +0.14 and +0.12 Snellen lines. BSCVA gained by a mean of +0.21, +0.2, and +0.1 Snellen lines. K(max) was reduced by a ...

2011-08-04

69

Functional MRI of the pharynx in obstructive sleep apnea (OSA) with rapid 2-D flash sequences; Funktionelle MRT des Pharynx bei obstruktiver Schlafapnoe (OSA) mit schnellen 2D-FLASH-Sequenzen  

Energy Technology Data Exchange (ETDEWEB)

Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager (`Vision`, Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, functional fiberoptic nasopharyngoscopy and polysomnography. A ...

1996-03-01

70

Towards an objective evaluation of tolerances for beam modeling in a treatment planning system  

International Nuclear Information System (INIS)

The performance of a convolution/superposition based treatment planning system depends on the ability of the dose calculation algorithm to accurately account for physical interactions taking place in the tissue, key components of the linac head and on the accuracy of the photon beam model. Generally the user has little or no control over the performance of the dose calculation algorithm but is responsible for the accuracy of the beam model within the constraints imposed by the system. This study explores the dosimetric impact of limitations in photon beam modeling accuracy on complex 3D clinical treatment plans. A total of 70 photon beam models was created in the Pinnacle(TM) treatment planning system. Two of the models served as references for 6 MV and 15 MV beams, while the rest were created by perturbing the reference models in order to produce specific deviations in specific regions of the calculated dose profiles (central axis and transverse). The beam models ...

2007-09-21

71

Radiation therapy for Ewing's sarcoma: Results from Memorial Sloan-Kettering in the modern era  

International Nuclear Information System (INIS)

Purpose: To evaluate the outcomes of patients with Ewing's sarcoma family of tumors (ESFT) treated with modern radiotherapy techniques with MRI along with optimal chemotherapy. Methods and Materials: The records of all 60 patients with ESFT who received radiation to the primary site between 1990 and 2004 were reviewed. All patients received chemotherapy, including vincristine, doxorubicin, cyclophosphamide, ifosfamide, and etoposide. Radiation was used as the sole modality for local control in 31 patients and was given either before (n = 3) or after surgical resection (n = 26) in the remainder. All patients had MRI and CT scan-based treatment planning, and 43% received intensity-modulated radiation therapy. Radiation doses ranged from 30 Gy to 60 Gy (median, 51 Gy), and 35% received hyperfractionated radiotherapy. Results: Median age was 16 years (range, 2-40 years). Because of selection bias for radiotherapy, the majority of primary tumors were centrally located ...

2006-02-01

72

Monte Carlo simulation and dosimetric verification of radiotherapy beam modifiers  

International Nuclear Information System (INIS)

Monte Carlo simulation of beam modifiers such as physical wedges and compensating filters has been performed with a rectilinear voxel geometry module. A modified version of the EGS4/DOSXYZ code has been developed for this purpose. The new implementations have been validated against the BEAM Monte Carlo code using its standard component modules (CMs) in several geometrical conditions. No significant disagreements were found within the statistical errors of 0.5% for photons and 2% for electrons. The clinical applicability and flexibility of the new version of the code has been assessed through an extensive verification versus dosimetric data. Both Varian multi-leaf collimator (MLC) wedges and standard wedges have been simulated and compared against experiments for 6 MV photon beams and different field sizes. Good agreement was found between calculated and measured depth doses and lateral dose profiles along both wedged and unwedged directions for different depths and focus-to-surface ...

2001-11-01

73

Convolution/superposition using the Monte Carlo method  

International Nuclear Information System (INIS)

The convolution/superposition calculations for radiotherapy dose distributions are traditionally performed by convolving polyenergetic energy deposition kernels with TERMA (total energy released per unit mass) precomputed in each voxel of the irradiated phantom. We propose an alternative method in which the TERMA calculation is replaced by random sampling of photon energy, direction and interaction point. Then, a direction is randomly sampled from the angular distribution of the monoenergetic kernel corresponding to the photon energy. The kernel ray is propagated across the phantom, and energy is deposited in each voxel traversed. An important advantage of the explicit sampling of energy is that spectral changes with depth are automatically accounted for. No spectral or kernel hardening corrections are needed. Furthermore, the continuous sampling of photon direction allows us to model sharp changes in fluence, such as those due to collimator tongue-and-groove. The use of explicit ...

2003-07-21

74

Three-dimensional simulation study of compact toroid plasmoid injection into magnetized plasmas  

Energy Technology Data Exchange (ETDEWEB)

Three-dimensional dynamics of a compact toroid (CT) plasmoid, which is injected into a magnetized target plasma region is investigated by using magnetohydrodynamic (MHD) numerical simulations. It is found that the process of the CT penetration into this region is much more complicated than what has been analyzed so far by using a conducting sphere (CS) model. The injected CT suffers from a tilting instability, which grows with the similar time scale as the CT penetration. The instability is accompanied by magnetic reconnection between the CT magnetic field and the target magnetic field, which disrupts the magnetic configuration of the CT. Magnetic reconnection plays a role to supply the high density plasma initially confined in the CT magnetic field into the target region. Also, the penetration depth of the CT high ...

1999-04-01

75

CT diagnosis of intrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Purpose: To evaluate contrast-enhanced CT scan in the diagnosis of intrahepatic cholangiocarcinoma by correlating the CT appearance with pathologic specimens. Materials and methods: Twenty-eight patients with pathologically proven intrahepatic cholangiocarcinoma were examined. Unenhanced abdominal CT study were performed in 28 patients; conventional contrast-enhanced CT in 27 patients. Enhanced CT scan including fast injection, fast scan and delayed scan at the largest section of the lesion was done in 7 patients. Contiguous 10 mm CT scans of the surgical specimens were also obtained in 8 patients. The preoperative and specimen CT scans in these 8 patients were compared with the corresponding pathological sections. A total of 103 areas of the pathological sections was compared with the CT appearances. Results: All ...

77

Role of CT in TNM staging of laryngeal and hypopharyngeal tumors  

International Nuclear Information System (INIS)

70 patients with squamouscell carcinoma of larynx and hypopharynx were examined by computed tomography; the TNM staging of tumors by CT, by endoscopy and by surgical operation was reviewed. CT proved to be reliable both to recognize the presence of neoplasms, with the exception of those very superficial, and their deep spreading to preepiglottic and paralaryngeal spaces, to the soft tissues of the neck and to the cartilages. Therefore CT is the examination of choice in laryngeal neoplasms staging, because it precisely completes the clinical and endoscopical informations.

1986-01-01

79

Computed tomography - old ideas and new technology  

International Nuclear Information System (INIS)

Several recently introduced 'new' techniques in computed tomography - iterative reconstruction, gated cardiac CT, multiple-source, and dual-energy CT - actually date back to the early days of CT. We review the historic origins and evolution of these techniques, which may provide some insight into the latest innovations in commercial CT systems. (orig.)

2011-03-01

80

CT-guided percutaneous aspiration and drainage of postoperative abdominal fluid collections  

International Nuclear Information System (INIS)

The authors report the personal techniques and the results of CT-guided percutaneous drainage of postoperative abdominal fluid collections. CT-guided percutaneous drainage offers many advantages over surgery: it is less invasive, can be repeated and requires no anesthesia, there are not surgery-related risks and lower morbidity and mortality rates. Moreover, subsequent hospitalization is shorter and costs are consequently reduced. The authors conclude that CT-guided percutaneous drainage is the method of choice in the treatment of postoperative abdominal fluid collections.

1999-03-01

81

CT colonography. Virtual coloscopy; CT-Kolonographie. Virtuelle Koloskopie  

Energy Technology Data Exchange (ETDEWEB)

The CT colonography or virtual coloscopy is a new diagnostic method that allows the presentation of the whole colon using minimal invasive procedures. The method allows the detection of colorectal polyps and colorectal carcinomas. The book includes the following chapters: indications for CT colonography, diagnostic procedures, data processing and interpretation, diagnostic findings, preparation of the diagnostic result description and documentation, screening.

2009-07-01

82

The imaging findings of small({<=}15mm) portal defects in the liver on CT arterial portography : evaluation with CT hepatic arteriography and lipiodol CT  

Energy Technology Data Exchange (ETDEWEB)

To assess the malignant potential of small({<=}15mm) portal defects seen on CT arterial portography, the findings of CT hepatic arteriography and lipiodol CT were reviewed. In 91 patients who underwent both CTAP and CTHA, small portal defects were reviewed for frequency, multiplicity and location. We prospectively evauluated changes in the size and enhancement pattern of malignant lesions on follow up CT according to density on CTHA, location, lipiodol deposits on lipiodol CT, and multiplicity. Among the 91 patients, 102 small defects were defected in 42 patients(46%). Small portal defects were benign, malignant, and of undetermined malignant potential in 77%, 20% and 3% of cases, respectively. Small portal defects that were hyperattenuated on CTHA, and lipiodol deposits on lipiodol CT, were malignant in 42% and 70% of cases, respectively. Location and ...

1999-05-01

83

CT versus MRI in the study of the articular diseases of the knee  

International Nuclear Information System (INIS)

The authors present a comparison between the diagnostic accuracy of Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) in the articular pathologies of the knee. CT and MRI were performed in 30 patients who subsequently underwent surgery. CT and MRI results were compared on three bases: technique, definition of normal anatomy, and diagnostic accuracy. CT allowed a standardization of the technique, while MRI was superior in defining normal anatomy - especially in the study of capsulo-ligamentous structures. In all cases the use of both CT and MRI allowed a correct diagnosis, showing the site, extent and gravity of the lesion. CT proved to be superior to MRI in 4 cases, while MRI corrected CT diagnosis in 11 cases; in 15 patients both techniques had the same diagnostic accuracy. Meniscal tears were better identified by ...

1988-01-01

84

PET/CT-guided interventional procedures: rationale, justification, initial study, and research plan  

International Nuclear Information System (INIS)

Positron-emission tomography (PET) and PET/CT (computed tomography) are becoming increasingly important for diagnosis and treatment of cancer. Clinically relevant changes can sometimes be seen on PET that are not seen on other imaging modalities. However, PET is not suitable for guiding biopsy as the images are not obtained in real-time. Therefore, our research group has begun developing a concept for PET/CT-guided interventional procedures. This paper presents the rationale for this concept, outlines our research plan, and includes an initial study to evaluate the relative sensitivity of CT and PET/CT in detecting suspicious lesions. (orig.)

2007-06-01

85

Differential diagnosis by CT units with contrast enhancement  

Energy Technology Data Exchange (ETDEWEB)

Variation of CT units, in organs, before and after using contrast enhancing medium was reviewed and personal experience was presented. In the normal brain CT units was little changed by contrast enhancement (CE), whereas remarkable change was observed at lesions. No difference of CT units was observed between the normal liver and hepatomas. The normal kidney had higher CE effect than hypernephromas suggesting an increase of the sensitivity. CE was not found in cysts or necrosis. The changes of CT units in the cases of cerebral diseases are tabled with various contrast medium and scanners.

1981-04-01

86

Computed tomography in the evaluation of soft tissue tumors  

International Nuclear Information System (INIS)

In order to evaluate the role of Computed Tomography (CT) in prediction of nature, staging and follow-up of soft-tessue tumors, the authors examined by CT 124 patients with soft tissue neoplasms who later underwent surgery (116 cases) or fine needle biopsy (8 cases). Comparison between CT and surgical or anatomical results showed that CT was able to correctly predict the benignancy or malignancy of the masses in 76% of cases but it was very seldom able to allow an hystological prediction. On the contrary CT was found to be a very useful tool for pre-therapeutic staging and follow-up of the tumors, because it gave many diagnostic information which influenced therapeutic choiches and strategies.

1986-01-01

87

Computed tomography in spinal osteoblastoma  

International Nuclear Information System (INIS)

In order to stress the role of computed tomography (CT) in the evaluation of benign spinal osteoblastoma, the authors examined by CT 10 patients with surgically and histologically proved osteoblastomas of the spine. Basing on surgical and histopathological findings CT proved to be a very important method for attesting the presence of the tumors (usually showed by radiographic examination), and specially for their staging and follow-up. CT in fact showed the real extent of the tumor into the spinal canal and towards the paraspinal soft tissues, and allowed the aerly detection of post surgical relapses. The authors conclude that CT is a primary diagnostic modality for preoperative planning and follow-up of benign osteoblastoma.

1986-01-01

88

Cerebral and meningeal manifestations of AIDS: Sensitivity of CT and T sub 2 -weighted MR (129 patients). Zerebrale und meningeale Manifestation des AIDS: Sensitivitaet von CT und T sub 2 -gewichteter MRT (129 Patienten)  

Energy Technology Data Exchange (ETDEWEB)

We studied 129 AIDS patients with suspected or proved intracranial manifestations of the disease. The purpose of this study was to compare the diagnostic sensitivity of unenhanced and contrast enhanced CT and unenhanced T{sub 2}-weighted MR. Thus, in 20% of our patients MR but not CT was diagnostic. In another 20% MR provided additional diagnostic information. In conclusion, MR is recommended as the imaging modality of choice in AIDS patients with non-conclusive cranial CT. (orig./GDG).

1990-09-01

89

Analysis of brain CT on 120 patients of human cysticercosis  

International Nuclear Information System (INIS)

A study on brain CT was made in 120 patients of human cysticercosis, which is a rare disease in Japan and clinical symptoms and laboratory data for the diagnosis were also discussed. From the point of therapeutic view, we proposed a new differentiation on brain CT of human cysticercosis, which is divided into two groups according to the alve or dead parasite. Furthermore, we proposed a new type named multiple large and small cysts type on brain CT. The idea of diagnostic standard was made integrating brain CT image, clinical symptoms and labolatory data. (author).

90

Quality of life in patients with head and neck cancers.  

UK PubMed Central (United Kingdom)

OBJECTIVE: The aim was to assess the psychosocial effects on the quality of life (QOL) of adults with head and neck cancer (HNC) and any gender variations with predictive factors that may influence...Full Text Available

2006-05-01

91

Measuring head for radionuclide X-ray fluorescence analyzer  

International Nuclear Information System (INIS)

The design of a gaging head for a portable radionuclide X-ray fluorescence analyzer is described. The gaging head is designed as a construction unit system which enables the application of lateral reflexion geometry as well as of coaxial geometry. It is designed so that adjustment from one geometry to the other is labour and time saving. The selection of characteristic radiation is performed by a couple of Ross' differential filters. These filters are prepared by a novel technique developed by our laboratory. The filter exchange is effected by the longitudinal move of the couple of filters encapsulated in a holder. The shift of the filters is controlled by means of a triggering mechanism situated in the body of the gaging head handle. This design makes is possible to handle the gaging head during measurements with one hand. A simple interchange of the absorption filter for the transmissive filter allows ...

1976-05-21

92

Magnetic resonance imaging findings in 46 elbows with a radial head fracture  

UK PubMed Central (United Kingdom)

Background and purposeRadial head fractures are common, and may be associated with other injuries of clinical importance. We present the results of a standard additional MRI scan...Full Text Available

2010-06-01

93

Lack of Osteoradionecrosis of the Mandible after IMRT for Head and Neck Cancer: Likely Contributions of both Dental Care and Improved Dose Distributions  

UK PubMed Central (United Kingdom)

PurposeTo assess the prevalence and the dosimetric and clinical predictors of mandibular osteoradionecrosis (ORN) in patients with head and neck (HN) cancer who underwent...Full Text Available

2007-06-01

94

Head and Neck Sentinel Lymph Node Biopsy: Current State of the Art  

UK PubMed Central (United Kingdom)

Sentinel node biopsy is an alternative to elective neck dissection for the management of T1/T2 oral and oro-pharyngeal squamous cell carcinomas and is also finding application to head and neck cancer...Full Text Available

95

Effects of Age on Optical Coherence Tomography Measurements of Healthy Retinal Nerve Fiber Layer, Macula and Optic Nerve Head  

UK PubMed Central (United Kingdom)

PurposeTo determine the effects of age on global and sectoral peripapillary retinal nerve fiber layer (RNFL), macular thicknesses and optic nerve head (ONH) parameters...Full Text Available

2009-06-01

96

Read/write characteristics of focused-ion-beam-etched heads for perpendicular magnetic recording media  

International Nuclear Information System (INIS)

The read/write characteristics for perpendicular magnetic recording media of focused-ion-beam (FIB)-etched recording heads were investigated. It was found that the trailing edge of an FIB-etched head produces a higher gradient in the magnetic field perpendicular to the medium than a head which has not been etched. The signal-to-noise ratio of the medium increased with the FIB-etched write gap. A high-Bs and thin pole increased the magnetic field's gradient in the perpendicular direction, resulting in excellent read/write characteristics.

2001-10-01

97

ProgDERAILED2.PDF  

Wastenet

and its consequences on customers and transport services -Dr Alexander Hedderich, Deutsche Bahn AG, Head of Competition (

98

DoseWatchers - A computer based X ray dose monitoring project in paediatric radiology  

International Nuclear Information System (INIS)

Full text: Introduction. Children, especially premature infants and neonates, are at a much higher risk to obtain an X ray induced disturbance of life - particularly cancer. On the one hand this is due to their longer life expectancy and on the other hand it is due to their higher cell proliferation rate. The paediatric radiology unit of the Inselspital Bern recently installed some of the most advanced X ray equipment nowadays available. It is based on the two latest digital technologies: double read computed radiography (CR) and direct digital radiography (DR). Only the implementation of these digital radiography systems permits the digital acquisition and additionally the analysis of acquired data. The systematic analysis of large amounts of biometric data and exposition data is the basis for further dose reduction and a systematic quality control (QC). Patients are increasingly critical concerning radiation exposure - especially parents regarding their children. ...

2006-11-13

99

Prospective evaluation of femoral head viability following femoral neck fracture  

International Nuclear Information System (INIS)

The bone scans of 33 patients (pts) with recent subcapital fractures (fx) of the femur were evaluated prospectively to determine their value in predicting femoral head visability. Each of the 33 pts (ll men, 22 women, age range 30-92) had a pre-operative bone scan within 72 hrs of the fx (23 pts within 24 hrs). Anterior and posterior planar views of both hips and pinhole views (50% of pts) were obtained 2 hrs after administration of Tc-99m HDP. The femoral head was classified as perfused if it showed the same activity as the opposite normal side or if it showed only slightly decreased activity. Femoral heads showing absent activity were classified as nonperfused. Overall, 20 of the 33 pts showed a photopenic femoral head on the side of the fx. Only 2 pts showed increased activity at hte site of the fx. Internal fixation of the fx was performed in 23 pts, 12 of whom had one or more follow-up scans. Five ...

1984-06-05

100

Mandrel head for pressing out patches during repair of casing columns  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this invention is to assure operating reliability of a Mandrel head in tubes of various diameters. This goal is achieved in that it is equipped with movable expanding sectors, which are installed on a rigid conical plunger dye. It is also equipped with spring-loaded conical slides blocks which are installed on a shaft. The upper ends of the sectors of the sectorial head are attached by hinges to a rigid cone shaped plunger dye. The lower ends are installed with the possibility of interacting with the slide blocks.

1980-07-17

101

Enhanced CT in the diagnosis of acute appendicitis to evaluate the severity of disease. Comparison of CT findings and histological diagnosis  

Energy Technology Data Exchange (ETDEWEB)

To assess the potential of CT in evaluating the histological severity of acute appendicitis in comparison with surgical and pathological findings. The CT images of 75 patients with surgically proven appendicitis, including 10 cases of catarrhal, 34 of phlegmonous, and 31 of gangrenous appendicitis, were retrospectively analyzed for the following five CT findings: hazy periappendiceal densities, enlarged appendix, increased enhancement of the appendiceal wall, increased enhancement of the periappendiceal intestinal wall, and deficiency of the appendiceal wall. By comparing all the CT findings and the pathological severity of appendicitis (catarrhal, phlegmonous, and gangrenous), the prevalence of the five CT findings was calculated for each pathological category. Abnormal CT findings were noted in only one case of catarrhal appendicitis. Increased enhancement of ...

2001-08-01

102

CT-Expo - a novel program for dose evaluation in CT  

International Nuclear Information System (INIS)

CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey on CT practice. Three different application modules offer free ...

2002-12-01

103

An evaluation of low-dose single-slice helical CT in pulmonary CT scan  

International Nuclear Information System (INIS)

Objective: To investigate the feasibility of low-dose single-slice helical CT in pulmonary CT scan and evaluate the clinical application. Methods: Thirteen cases were selected out of 132 cases, in which low-dose (50mAs) single-slice helical CT scan of chest was performed. This set of cases included 7 cases of multiple metastatic nodules; 3 of solitary pulmonary, nodule; and 3 of pulmonary patchy lesions. Regular dose (170mAs) CT scan was also performed on all those patients. The regular dose and low dose CT scan were compared on sensitivity of detecting the lesions; the performance in demonstrating the details of the abnormalities; and the capability of revealing the segmental bronchi as well. Results: The same number and size of the pulmonary nodules were revealed with scan modalities loaded with different doses. No significant difference in demonstrating the details of the nodules ...

2006-04-01

104

Diagnostic value of immediate CT after chemoembolization in patients with hepatocellular carcinoma: comparison with 2-3 week delayed CT  

Energy Technology Data Exchange (ETDEWEB)

Lipiodol CT is a important modality for the diagnosis of hepatocellular carcinoma and compared is usually performed at 2-3 week after Lipiodol injection. Therefore, we assessed and the diagnostic value and merits of immediate CT after chemoembolization from there of 2-3 week delayed Lipiodol CT. Thirty three cases of chemoembolization which were performed both immediate CT after chemoembolization and 2-3 week delayed Lipiodol CT were reviewed retrospectively. They were divided into four grades according to pattern of lipiodol uptake by three radiologists. The diagnostic value of immediate Lipiodol CT was compared to delayed Lipiodol CT. Grade 0 was two cases(3.0%) and Grade 1 was seven cases(21.2%). In the cases of Grade 2(23/33, 69.7%), tumor uptake could be dishing wished from parenchymal uptake of Lipiodol by its density and pattern, ...

1995-08-15

105

CT-Expo - a novel program for dose evaluation in CT; CT-Expo - ein neuartiges Programm zur Dosisevaluierung in der CT  

Energy Technology Data Exchange (ETDEWEB)

CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey on CT practice. Three different application modules offer free ...

2002-12-01

106

Improving surgical outcome following the Norwood procedure  

British Library Electronic Table of Contents (United Kingdom)

Background The Norwood procedure consists of three palliative operations, performed in neonates with hypoplastic left heart syndrome. Especially the first stage (Norwood I) is associated with the highest mortality rates in paediatric cardiac surgery (up to 25%). During surgery, the aorta is reconstructed and a systemic-to-pulmonary shunt is applied. Originally the modified Blalock-Taussig shunt was used, but recently the right-ventricle-to-pulmonary-artery shunt is increasingly being employed. We reviewed the results of our operative strategy, where an individualised choice of shunt is made. Furthermore, attempts to reduce interstage mortality (between Norwood I and II) were assessed. Methods All neonates who underwent Norwood stage I palliation from August 2004 until November 2010 were in...

2011-01-01

107

Bipolar Disorder in Children and Adolescents Recognised in the UK: A Clinic-Based Study  

British Library Electronic Table of Contents (United Kingdom)

Background:- Diagnoses of paediatric bipolar disorder have increased over the last two decades in the United States, where high levels of comorbidity with ADHD have also been reported. Aims:- To explore how British clinicians apply these diagnoses. Method:- We compared 378 young people under the age of 18 who received a diagnosis of bipolar disorder and/or ADHD from a large NHS mental health trust between 1992 and 2007. Results:- Children with bipolar disorder were rare in this sample (n-=-35, 1.0%), particularly under the age of 13 (n-=-9, 0.3%). Children with bipolar disorder presented more often with affective and psychotic symptoms than children with ADHD. Irritability was common in both disorders. Core ADHD symptoms were prevalent in both conditions but occurred in a greater proportio...

2011-01-01

108

Computed Tomography of the spine in multiple myeloma  

International Nuclear Information System (INIS)

Computed Tomography (CT) of the spine was performed on 17 patients with myeloma in order to assess the role of the technique in recognizing and evaluating the extent of the lesions. Myelomatous lesions followed two patterns at CT: first of all, multiple focal lesions, whose density is either solid, liquid, or fatty; second, an extensive pattern involving the spongiosa of the vertebra, including the posterior arch. CT detected more lesions than conventional radiology; furthermore, the extent of the lesions was much better demonstrated by CT. CT should thus be performed: a) in case of pain and/or neurological findings in negative radiological examinations; b) to evaluate the extent of myelomatous lesions (mainly in the spine); c) in solitary myeloma CT may be performed on different bone segments with clinical symptomatology but normal X-ray findings.

1988-01-01

109

Head pose estimation in computer vision: a survey.  

Science.gov (United States)

The capacity to estimate the head pose of another person is a common human ability that presents a unique challenge for computer vision systems. Compared to face detection and recognition, which have been the primary foci of face-related vision research, identity-invariant head pose estimation has fewer rigorously evaluated systems or generic solutions. In this paper, we discuss the inherent difficulties in head pose estimation and present an organized survey describing the evolution of the field. Our discussion focuses on the advantages and disadvantages of each approach and spans 90 of the most innovative and characteristic papers that have been published on this topic. We compare these systems by focusing on their ability to estimate coarse and fine head pose, highlighting approaches that are well suited for unconstrained environments. PMID:19229078

2009-04-01

110

Forming the COUNCIL Based Clusters in Securing Wireless Ad Hoc Networks  

CERN Document Server

In cluster-based routing protocol (CBRP), two-level hierarchical structure is successfully used to reduce over-flooding in wireless Ad Hoc networks. As it is vulnerable to a single point of failure, we propose a new adaptive distributed threshold scheme to replace the cluster head by a group of cluster heads within each cluster, called COUNCIL, and distribute the service of single cluster head to multiple cluster heads using (k,n) threshold secret sharing scheme. An Ad Hoc network formed by COUNCIL based clusters can work correctly when the number of compromised cluster heads is smaller than k. To implement this adaptive threshold scheme in wireless Ad Hoc Networks, membership of the clusters should be defined in an adaptive way. In this paper, we mainly discuss our algorithm for forming COUNCIL based clusters using the concept of dominating set from graph theory.

2010-01-01

111

Scintigraphical observation of femoral head in femoral neck fractures. Comparison with histological findings  

Energy Technology Data Exchange (ETDEWEB)

In 10 cases of femoral neck fracture treated with prosthetic replacement, the preoperative sup(99m)Tc-MDP scintigraphs were investigated and then compared with each histological findings of the extracted femoral head. The appearances of the scintigraphs were classified into following 3 patterns; increased activity pattern of sup(99m)Tc-MDP uptake in the overall femoral head (type I) in 4 cases, deficient activity pattern at the lateral side correspond to weight-bearing area (type II) in 2 cases and considerably deficient activity pattern in the whole femoral head (type III) in remaining 4 cases. Histological examination of the extracted femoral heads revealed the narrow part of ischemic necrosis in type I. However type II showed extensive necrosis in the portion of deficient activity by scintigraphs and in type III, the femoral heads except articular cartilage were entirely ...

1984-06-01

112

Scintigraphical observation of femoral head in femoral neck fractures  

International Nuclear Information System (INIS)

In IO cases of femoral neck fracture treated with prosthetic replacement, the preopera tive sup(99m)Tc-MDP scintigraphs were investigated and then compared with each histological findings of the extracted femoral head. The appearances of the scintigraphs were classified into following 3 patterns; increased activity pattern of sup(99m)Tc-MDP uptake in the overall femoral head (type I) in 4 cases, deficient activity pattern at the lateral side correspond to weight-bearing area (type II) in 2 cases and considerably deficient activity pattern in the whole femoral head (type III) in remaining 4 cases. Histological examination of the extracted femoral heads revealed the narrow part of ischemic necrosis in type I. However type II showed extensive necrosis in the portion of deficient activity by scintigraphs and in type III, the femoral heads except articular cartilage were entirely ...

113

TLD assessment of mouse dosimetry during microCT imaging  

UK PubMed Central (United Kingdom)

Advances in laboratory animal imaging have provided new resources for noninvasive biomedical research. Among these technologies is microcomputed tomography (microCT) which is widely used to obtain high...Full Text Available

2008-09-01

114

SEGMENTING CT PROSTATE IMAGES USING POPULATION AND PATIENT-SPECIFIC STATISTICS FOR RADIOTHERAPY  

UK PubMed Central (United Kingdom)

This paper presents a new deformable model using both population and patient-specific statistics to segment the prostate from CT images. There are two novelties in the proposed method. First,...Full Text Available

2009-08-07

115

Role of CT in the assessment of the volume to be irradiated in bone metastases  

International Nuclear Information System (INIS)

In the Department of Radiology of Catholic University S. Cuore in Rome, a review was made of 342 CT examinations with a view towards optimizing the therapeutic planning in patients affected by bone metastases. All patients were submitted to radiological positioning and then to CT evaluation in order to assess the volume to be treated. In 224 cases it was not necessary to perform wide CT examination (3-5 standard tomograms being enough, 2 of which at the superior and inferior margins of the planned field). In the second group of 118 patients it was necessary to perform CT (serial axial scans) - increasing by 1-1.5 cm - up to the superior and inferior margins of the lesion. The existence of 2 types of lesions was confirmed: those involving mainly bony structures and those infiltrating the soft tissues. CT evaluation allowed the definition of the target volume to the real extension of ...

1988-01-01

116

Range accuracy in carbon ion treatment planning based on CT-calibration with real tissue samples  

UK PubMed Central (United Kingdom)

BackgroundThe precision in carbon ion radiotherapy depends on the calibration of Hounsfield units (HU) as measured with computed tomography (CT) to water equivalence. This calibration...Full Text Available

117

Multiscale registration of planning CT and daily cone beam CT images for adaptive radiation therapy  

UK PubMed Central (United Kingdom)

Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available

2009-01-01

118

Longitudinal assessment of lung cancer progression in the mouse using in vivo micro-CT imaging  

UK PubMed Central (United Kingdom)

Purpose: Small animal micro-CT imaging is being used increasingly in preclinical biomedical research to provide phenotypic descriptions of genomic models. Most of this imaging is coincident...Full Text Available

2010-09-01

119

Localization of islet cell tumors by dynamic CT: comparison with plain CT, arteriography, sonography, and venous sampling  

Energy Technology Data Exchange (ETDEWEB)

Ten patients with suspected islet cell tumors (seven with possible gastrinomas, three with insulinomas) underwent diagnostic evaluation with dynamic CT scanning, routine CT scanning, angiography, and sonography. Venous sampling was also performed in selected instances. Nine sites of gastrinoma and three insulinomas were confirmed surgically in eight patients. Two patients had negative surgical explorations. Routine CT demonstrated five of the nine gastrinomas and one of two insulinomas. Angiography was positive in six of nine gastrinomas and all three insulinomas. Sonography showed only two of the nine gastrinomas and two of the three insulinomas. Dynamic CT scanning demonstrated three additional lesions (two gastrinomas, on insulinoma) not visible on routine CT scanning. Although most of these lesions were visible arteriographically, dynamic CT scans at the ...

1984-09-01

120

Ganglioneuromas in childhood: MRI and CT characteristics  

International Nuclear Information System (INIS)

Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in ...

2000-05-01

121

Effect of Edge-Preserving Adaptive Image Filter on Low-Contrast Detectability in CT Systems: Application of ROC Analysis  

UK PubMed Central (United Kingdom)

Objective. For the multislice CT (MSCT) systems with a larger number of detector rows, it is essential to employ dose-reduction techniques. As...Full Text Available

2008-01-01

122

Diagnostic Performance of Computed Tomography Colonography in Symptomatic Patients and in Patients with Increased Risk for Colorectal Disease  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate the diagnostic performance (colorectal lesions) of computed tomography (CT) colonography in 111 patients, a majority of whom were at high risk for colorectal neoplasia. Material and Methods: After bowel preparation, CT colonography was performed, immediately followed by conventional colonoscopy. The diagnostic performance of CT colonography was analyzed relative to lesion size, histological diagnosis, and diagnostic certainty. Results: The sensitivity of CT colonography increased with lesion size (P<0.001), and was 91% (21/23) for lesions > or = 10 mm. All 10 carcinomas and 86% (19/22) of adenomas > or = 5 mm were detected. Unconfirmed or false-positive CT findings were generally small and/or reported with low diagnostic certainty. The specificity of CT colonography would be 45% (30/66; 95% CI 34% to 57%) if patients ...

2006-11-15

123

Clinical value of SPECT/CT for evaluation of patients with painful knees after total knee arthroplasty- a new dimension of diagnostics?  

UK PubMed Central (United Kingdom)

BackgroundThe purpose of our study was to evaluate the clinical value of hybrid SPECT/CT for the assessment of patients with painful total knee arthroplasty (TKA).MethodsTwenty-three...Full Text Available

124

CT evaulation of thoracic and abdominal fatty masses  

International Nuclear Information System (INIS)

The diagnostic accuracy of computed tomography (CT) in several patterns of thoracic and abdominal fatty masses, has been examined. In selected cases our findings overlap the features of the recent literature. The possibility of surgical therapy in peculiar cases of adipose deposits, commonly esteemed benign, is considered.

1986-01-01

125

Value of computed Tomography in re-staging patients undergoing second-look laparotomy for ovarian cancer  

International Nuclear Information System (INIS)

Twenty-five patients with ovarian carcinoma who had been operated and treated with chemotherapy underwent clinical examination and CT before reintervention (second-look laparotomy) to detect the presence of eventual recurrences. The prediction of recurrence based on CT and clinical findings was compared with the surgical findings at reintervention. CT proved to be more accurate than clinical examination in detecting recurrences; this was especially true for masses in the abdominal cavity, with the exception of small peritoneal nodules. The authors suggest the use of CT for staging the patients candidate to reintervention. This might help to avoid reintervantion in patients with persistent disease and to plan treatment.

1991-01-01

127

PET/CT cardiology: an area whose boundaries are still out of sight  

International Nuclear Information System (INIS)

Positron emission tomography (PET) and X-ray computed tomography (CT) performed with PET/CT cameras allow us to obtain concurrently information on the presence and degree of alterations of myocardial perfusion and metabolism and on coronary arteries calcification. Furthermore, by gated myocardial perfusion studies, PET may provide crucial information on regional coronary blood flow reserve and endothelial dysfunction. A number of recent papers provide some insight on the potential of PET/CT in cardiology and in the assessment of various cardiovascular diseases including various types of vasculitis and metabolic diseases.

2006-05-01

128

New mass screening project for lung cancer with mobile spiral computed tomography (CT) and computed radiography (CR) in Ehime district  

Energy Technology Data Exchange (ETDEWEB)

To improve the detection rate of lung cancer, we have introduced low-dose CT and CR technique into a population-based annual mass screening. From December 1999, 3868 and 12618 individuals participated in this screening program with CT and with CR, respectively. Primary lung cancer was detected in 15 (0.39%) by CT and 8 (0.06%) by CR. This results show high detection rate of primary lung cancer as had been previously reported. (author)

2002-01-01

129

Computed Tomography of the cranio-cervical junction in rhematoid arthritis  

International Nuclear Information System (INIS)

Twenty rheumatoid arthritis (RA) patients with involvement of the cranio-cervical junction (CCJ) were given CT scan. In most cases the myelo-CT technique with the lumbar injection of small quantities of non-ionic contrast medium was adopted; CT easily diagnosed the horizontal and vertical dislocations on the CCJ, the bone strcture lesions and the inflammatory masses. A high frequency of medullary compressions was also found in these patients. Myelo-CT appears to be the technique of choice for the precise definition of the various factors responsible for the neurological complications found in RA of the CCJ.

1987-01-01

130

CT-pathologic correlation of focal area of ground-glass attenuation (GGA) in the peripheral lung  

Energy Technology Data Exchange (ETDEWEB)

We compared the characteristics on thin-section CT images with the histological structure of thirty-four surgically resected peripheral lung lesions 30 mm or less in diameter with a greater than 50% area of GGA on thin-section CT. Pathologically, focal area of GGA corresponded to alveolar replacement growth of tumor or interstitial fibrotic thickening of inflammation. It is considered that determination of the GGA in small peripheral lung lesions on thin-section CT is useful for the diagnosis of early adenocarcinomas. (author)

2001-07-01

131

Lung studies with spiral CT. pitch 1 versus pitch 2  

International Nuclear Information System (INIS)

In Spiral CT, the pitch is the ratio of the distance to tabletop travels per 360 degrees rotation to nominal slice width, expressed in mm. Performing Spiral CT examination with pitch 2 allows to reduce examination time, exposure and contrast dose, and X-ray tube overload. The authors investigated the yield of pitch 2 in lung parenchyma studies, particular relative to diagnostic image quality.

1999-03-01

132

Dosimetry in dental radiology. Dentascan spiral CT versus panoramic radiography  

International Nuclear Information System (INIS)

The study compares the doses absorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations.

1999-05-01

133

Computer tomography of orbita in children  

Energy Technology Data Exchange (ETDEWEB)

The experiences are described of the examination of orbita in children using computer tomography (CT). Over a period of four years 42 examinations were performed of children in the age ranging between 7 months and 15 years, i.e., 2.7 percent of all CT examinations performed. The highest diagnostic yield was in orbita tumours. The possibilities of CT are demonstrated on examples.

1983-07-01

134

Computed tomography of the urinary bladder. Clinical application of the olive oil-filled method  

Energy Technology Data Exchange (ETDEWEB)

Out of one hundred cases of the urinary bladder abnormalities examined by this method, CT staging and pathological correlations were investigated in 61 cases of the urinary bladder neoplasms. Accuracy of CT staging was 87% in this series with possible exception of 6 cases involving the bladder base and dome. CT scan using this method is the most reliable procedure to determine the treatment modalities of the urinary bladder tumors.

1982-01-01

135

Computed tomography of the chest: A teaching file  

Energy Technology Data Exchange (ETDEWEB)

As a self-teaching tool, this illustrated guide facilitates home study of the complexities of thoracic CT's. Over 400 illustrations and accompanying copy are used to provide a basis for understanding the CT appearances of disease processes and a comparison of CT lookalikes. It updates new and interesting developments in the format of case presentations.

1987-01-01

136

CT scan findings in cerebral paragonimiasis  

International Nuclear Information System (INIS)

Computed tomography was performed on 5 patients with chronic cerebral paragonimiasis. CT showed solitary or multiple, amorphous, round, or oval calcifications, and ventricular enlargement in all 5 cases. A large low-density area is also found in 4 of the 5 cases. These CT findings are compatible with previously reported findings of simple X-ray films of the skull, pneumoencephalography, and pathological studies. (author).

1982-01-01

137

CT manifestations of ileal dysgenesis  

Energy Technology Data Exchange (ETDEWEB)

Ileal dysgenesis is an uncommon condition of unknown etiology occurring in the distal ileum in the region of the vitelline duct. The CT appearance of this lesion, although not previously described to our knowledge, is characteristic. We report a patient with ileal dysgenesis who had an abdominal CT scan to evaluate chronic iron deficiency anemia and protein-losing enteropathy. Recognition of this lesion by pediatric radiologists is important; so that surgical treatment, which is simple and effective, can be initiated quickly. (orig.)

2007-02-15

138

Disposal of old heads for Daya Bay NPP  

International Nuclear Information System (INIS)

The paper introduces the disposal procedures of the old reactor pressure vessel head. Reactor pressure vessel (RPV) heads were replaced successfully in Daya Bay Nuclear Power Plant. The on-site treatment and disposal of replaced heads was thereafter implemented. This is the first time in China for large size radioactive article disposal. To guarantee the safety of old head treatment, issues of radiation protection have to be taken into account. Dose rate distribution of the old head surface and radioactivity were initially calculated according to the operation history and the neutron flux rate of the reactor. Shielding calculation and package design was thereafter worked out based on the data obtained from the old head, e.g. neutron flux, sorts of nuclides, radioactivity and dose rates. Shielding package was afterwards manufactured in special factories and ...

139

Tracheal cross-sectional area in children: CT determination  

Energy Technology Data Exchange (ETDEWEB)

A computer method that calculates tracheal cross-sectional area by compensating for partial volume averaging was developed and validated in a study with phantoms. The program was then used to determine the tracheal cross-sectional area of 30 normal children who ranged in age from four months to 18 years. CT-derived cross sections were correlated with age, height, weight, and body-surface area, and they were compared with findings of published clinical and post-mortem studies. CT cross-sectional areas ranged from 20 to 275 mm/sup 2/, varied by as much as 22% at the three different tracheal levels studied, and appeared to correlate most closely with body height. CT-derived tracheal cross-sectional areas are quite similar to those in published reports of postmortem and clinical studies. Measurements of tracheal cross section by CT may prove useful in quantitating tracheal compromise by intrinsic or ...

1983-10-01

140

Tracheal compression by mediastinal masses in children: CT evaluation  

Energy Technology Data Exchange (ETDEWEB)

Chest computed tomography (CT) was valuable in detecting extrinsic tracheal compression by mediastinal masses in two pediatric patients. This prompted an independent evaluation by CT of 14 children with masses involving the middle mediastinum and possible intrathoracic tracheal narrowing. Computer programs permit precise calculation of tracheal cross-sectional areas. Any apparent decrease in tracheal area may be compared with CT-derived data in normal children. Chest CT not only demonstrates the presence of extrinsic airway compression in pediatric patients with mediastinal masses, but also is capable of precisely measuring the extent of this narrowing. This method identifies children at potential risk for respiratory compromise and may aid in subsequent therapy.

1983-10-01

141

Subdural effusions in children under two years. Clinical and computer-tomographical data  

Energy Technology Data Exchange (ETDEWEB)

We investigated 161 children under 24 months of age by CT of the skull and reviewed the anamnestic and clinical history. 87 children showed subdural effusions, and 74 did not. There were 33 patients with other pathological findings in CT, and 41 had normal scans. Age and sex distribution as well as localization of the subdural effusions were consistent with the literature. The 87 children with subdural effusions represented 17% in a sample of about 5000 CT scans. CT was the most reliable method for diagnosis of subdural effusions, compared to other techniques. There was a preponderance of small subdural effusions from 1 to 7 mm thickness (51%). Other CT abnormalities accompanying subdural effusions were found. Most frequently the interhemispheric sulcus was dilated and an internal hydrocephalus was present. Also in our group there were 7 anamnestical and 6 clinical symptoms highly ...

1980-05-01

142

Role of Computed Tomography in postoperative diskitis  

International Nuclear Information System (INIS)

Six patients with diskitis following lumbar disk surgery were investigated by Computed Tomography (CT). Four patients underwent CT in a rather early phase of the disease (5-37 days after the onset of the symptoms): a posterior paravertebral fluid collection was always recognized, while the plain film was normal. Later on (2-4 months), the classical signs of diskitis were evident, with both CT and the plain film. The collection was always present at CT. A reintervention, performed on 3 patients, revealed the purulent content of the collections. It seems reasonable to suggest a relationship between the collection and the subsequent diskitis; the collection is probably an early sign of the disease. Its detection is of grat value, because it could allow an immediate and adequate therapy. The authors stress the usefulness of performing CT in an early phase on this kind of symptomatic ...

1988-01-01

143

Reduction of diagnostic expense in space-occupying processes of the pancreas by fine-needle biopsy under computerized tomography (CT)  

International Nuclear Information System (INIS)

Comparative analysis of diagnostic accuracy (dignity determination) in CT-guided fine-needle biopsy (141 patients), CT (141), ultrasonography (89), angiography (50), and cholegraphy (ERCP, 55), was carried out in suspected space-occupying lesions of the pancreas. With accuracy of 86%, sensitivity of 37% and specificity of 92% fine-needle biopsy was superior to imaging procedures. Additional comparison of the results concerning the patients and Roc curves confirm the statements. For reduction of the number of imaging investigations a diagnostic algorithm is proposed, that starts with diagnostic CT and subsequent fine-needle biopsy controlled by CT. This would result in a more adequate use of angiography and ERCP and in the elimination of ultrasonography. (author).

144

Radiation risk in computerized tomography (CT)  

Energy Technology Data Exchange (ETDEWEB)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional ...

1984-01-01

145

Radiation risk in computerized tomography (CT)  

International Nuclear Information System (INIS)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional ...

1984-01-01

146

Radiation risk in computerized tomography (CT)  

International Nuclear Information System (INIS)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional ...

147

Lacrimal gland masses on CT and MRI: a report of four cases  

International Nuclear Information System (INIS)

In an extended case report, we discuss four cases with masses in the lacrimal fossa representing the most important entities in this region (lymphoma, pleomorphadenoma, inflammatory pseudotumor, and malignant epithelial tumor). The different indications for CT and MRI are explained. For the differential diagnosis of lacrimal gland lesions, the following imaging parameters are important: The shape of the lacrimal gland, the inner structure, the degree of contrast enhancement, and the surrounding bony structures. In the evaluation of the expansion of lacrimal gland lesions, CT in thin slices with multiplanar reconstructions is equal to MRI. However, the contrast-enhancement of lacrimal glands is better evaluated with MRI than with CT. The bony structures are better visualized on CT than on MRI. (orig.).

148

Formulation and practice of standards for radiation protection of #gamma#-ray industrial computed tomography  

International Nuclear Information System (INIS)

There are many differences between industrial CT and industrial radiography, such as imaging principle, inspection time, radiation dose and the requirements for operators etc. The national standards for radiation protection of industrial detection are not applicable to the requirements of protection and safety for #gamma#-ray industrial CT to some extent now. In order to standardize the production and use for #gamma#-ray industrial CT, protect the safety of operators and the public, and to promote the popularization and application of #gamma#-ray industrial CT, it is significant to establish the national standards for radiation protection of #gamma#-ray industrial CT as soon as possible. The purpose of this paper is to introduce the contents of this standard, and specify some important terms. Then there is a brief discussion on the existing problems during establishing such ...

2009-03-01

149

Detection of recurrence and the effect of transcatheter hepatic arterial embolization using lipiodol (Lp-TAE) assessed by the lipiodol accumulative pattern on CT  

Energy Technology Data Exchange (ETDEWEB)

We evaluated the relation between the lipiodol accumulative pattern on CT 1 month after 1st Lp-TAE and the effect of Lp-TAE and recurrence of hepatocellular carcinoma (HCC) in 70 cases undergoing Lp-TAE twice. The lipiodol accumulative pattern on CT can be classified into four types (I: homogeneous, II: defect, III: inhomogeneous, IV: no or slight). In the type I, recurrence of the main tumor was 26.7%, daughter was 73.7%, suggesting a good effect of Lp-TAE. In the types II, III and IV, recurrence of the main tumor was seen in 66.7%, 83.3% and 83.3%, respectively, suggesting that the effect of Lp-TAE was worse according to the lipiodol accumulative pattern on CT. The lipiodol accumulative pattern on CT is useful for the detection of recurrence and assessment of the effect of Lp-TAE. (author).

1993-08-01

150

Computed tomography of middle ear cholesteatomas without tympanic membrane perforation  

International Nuclear Information System (INIS)

The growth of a middle ear cholesteatoma behind a normal tympanic membrane is a rate though possible event. In such cases, CT may provide useful information for diagnosis. The results are presented of a CT study carried out on 14 patients affected with unilateral conductive hearing loss and with normal tympanic membrane. CT allowed the diagnosis of meddle ear cholesteatoma to be made in all cases. All patients were treated with surgery: 8 of them underwent tympanoplasty and 6 explorative tympanotomy. While the diagnosis of cholesteatoma was confirmed in 13 patients, in 1 case tympanosclerosis was diagnosed. CT diagnosis of middle ear cholesteatoma is based on the demonstration of a low-density soft-tissue mass, in association with bone erosion or ossicular dislocation. The author emphasizes the difficulty of a CT diagnosis of cholesteatoma in the patients with middle ear soft-tissue ...

1991-01-01

151

{sup 99m}Tc-MDP scintigraphy of femoral head necrosis following femoral neck fracture  

Energy Technology Data Exchange (ETDEWEB)

Secondary ischemic necrosis of femoral head due to loss of blood supply following to femoral neck fracture is well known. The regional distribution of bone-seeking radiopharmaceuricals in the skeleton can depend on a number of factors, but bone blood flow is a major physiological determinant of regional skeletal uptake of Tc-99m polyphosphate and bone imaging may thus be used for the evaluation of vascularity of the femoral head. The authors made a comparative study of scintigraphic findings and operative findings of 28 cases of femoral neck fracture treated at Kyung Hee University Hospital from April 1980 to May 1984. The results were as follows: 1. In 16 cases of proven avascular necorsis of femoral head, scintigraphy showed absent or decreased activity in 14 cases (87.5%), while radiography showed increased density in 10 cases (62.5%). 2. In 12 cases of proven vital femoral head, scintigraphy showed ...

1985-02-15

152

Multidetector-row helical CT: analysis of time management and workflow  

International Nuclear Information System (INIS)

The purpose of this study was to evaluate time management and workflow for multidetector-row helical CT (MDCT). Time for patient and data handling of at total of 580 patients were evaluated at two different time periods (December 1999, August 2000), each for the following baseline measurements: (a) change of clothes/instruction; (b) patient placement on the CT table/i.v. catheter; (c) CT planning and programming; (d) CT data acquisition; (e) CT data reconstruction; (f) CT data storage/printing. All imaging was performed on a Somatom Volume Zoom (Siemens, Erlangen, Germany). Time measurements summarized for different CT protocols revealed the following: (a) 5:01 min (#+-#2.06 min); (b) 4:36 min (#+-#2.43 min); (c) 4:11 min (#+-#2.55 min); (d) 0:43 min (#+-#0.15 min); (e) 6:59 min (#+-#2.39 min); (f) 09:51 min (#+-#3.51 min). Planning and ...

2002-03-01

153

High-End CT for clinical and scientific applications; High-End-CT im klinischen und wissenschaftlichen Einsatz  

Energy Technology Data Exchange (ETDEWEB)

The enhancements described of high-performance CT systems of latest design have again confirmed the importance of CT systems for acute and selective diagnostic imaging. Higher availability, shorter exposure times, and better applicability and handling for examination of poly-traumata patients or patients of intensive care departments are some of the advantages achieved with CT systems which demonstrate CT system efficiency in addition to MRI, which for specific examinations will remain the modality of first choice for diagnostic evaluation. The Tomoscan Av-E presented here was able to answer all relevant diagnostic questions appearing in routine diagnostics and scientific work. For patients, examinations using the spiral CT technique also offers significant advantages. (orig./CB) [Deutsch] Durch die dargestellten Verbesserungen bei Hochleistungs-CT-Systemen ...

1997-12-01

154

Value of micro-CT as an Investigative Tool for Osteochondritis Dissecans. A preliminary study with comparison to histology  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate micro computed tomography (micro-CT) for the assessment of osteochondritis dissecans in comparison with histology. Material and Methods: Osteochondritis dissecans lesions of 3 patients were evaluated using micro-CT (0.125 mA, 40 keV, 60 m slice thickness, 60 m isotropic resolution, entire sample) and light microscopy (toluidine blue, 3-5 m slice thickness). The methods were compared regarding preparation time, detectability of tissue types and morphologic features of bone and cartilage. Results: Non-destructive micro-CT imaging of the entire sample was faster than histologic preparation of a single slice for light microscopy. Morphologic features of bone and cartilage could be imaged in a comparable way to histology. It was not possible to image cells or different tissue types of bone and cartilage with micro-CT. Conclusion: Micro-CT is a fast, non-destructive ...

2003-09-01

155

Value of micro-CT as an Investigative Tool for Osteochondritis Dissecans. A preliminary study with comparison to histology  

International Nuclear Information System (INIS)

Purpose: To evaluate micro computed tomography (micro-CT) for the assessment of osteochondritis dissecans in comparison with histology. Material and Methods: Osteochondritis dissecans lesions of 3 patients were evaluated using micro-CT (0.125 mA, 40 keV, 60 m slice thickness, 60 m isotropic resolution, entire sample) and light microscopy (toluidine blue, 3-5 m slice thickness). The methods were compared regarding preparation time, detectability of tissue types and morphologic features of bone and cartilage. Results: Non-destructive micro-CT imaging of the entire sample was faster than histologic preparation of a single slice for light microscopy. Morphologic features of bone and cartilage could be imaged in a comparable way to histology. It was not possible to image cells or different tissue types of bone and cartilage with micro-CT. Conclusion: Micro-CT is a fast, non-destructive ...

2003-09-01

156

Ultrasonography and Computerized Tomography in the diagnosis of complex abdominal lesions  

International Nuclear Information System (INIS)

Complex abdominal lesions include a variety of pathologies, such as septated, infected, and hemorrhagic cysts, abscesses, tumors, and fluid collections of different ethiology. These lesions present diagnostic difficulties with both Ultrasonography (US) and Computed Tomography (CT), since findings may not be present or, when present, are not specific. Keeping these limitations in mind, we evaluated 105 patients (111 abdominal lesions) with both US and CT in order to compare their adequacy in predicting the nature of the lesion. On the basis of US and CT results, complex abdominal lesions were divided in four classes: class I includes 43 cases in which both examinations gave the same contribution to the definition of the nature of the lesion, class II (14 lesions, mainly sperimentated cysts), in which US was superior to CT, class III includes 45 cases of hemorrhagic cysts, abscesses, fluid collections ...

1988-01-01

157

The diagnostic value of MRI and gadolinium-DTPA compared with CT for the diagnosis of bladder tumours  

International Nuclear Information System (INIS)

In a prospective study, 58 patients with carcinomas of the bladder were examined by CT and MRI; in 48, gadolinium-DTPA was administered intravenously. MRI provided exact staging in 89%, compared with 80% with CT. There was 13% over-staging with CT and 11% with MRI. MRI, unlike CT did not result in any under-staging. In 36 patients a quotient could be calculated from the signal intensity of the tumour and surrounding soft tissues both before and after the intravenous contrast medium and the increased quotient after contrast administration could be estimated. There was a significant increase in the tumour/muscle quotient with a mean of 72#+-#22% (minimum 43%, maximum 153%), corresponding to a marked increase of the signal form the tumour when compared with the precontrast images. This had the following advantages compared with CT: Accurate differentiation between superficial and ...

158

Pelvic CT for the prognostic evaluation of anorectal malformation  

International Nuclear Information System (INIS)

The anatomical patterns of anorectal malformations have so far been studied according to the principles which inspire Pena's technique for the surgical treatment of anorectal anomalies. Thus, the diagnostic study of anorectal malformation has by the authors been considered a work of classification, but of identification. Among the diagnostic procedures in use in author's Institute, preoperative CT of pelvis is performed to assess the presence and to define the development of muscular sphincteric structure towards prognostic evaluation of continence, the major long-term goal. Seven patients, aged 1-30 months, with anorectal anomalies were studied with preoperative CT of the pelvis. CT scans showed well-developed sphinteric muscles in 3 patients (2 with recto-ureteral and 1 with recto-vestibular fistulas), poorly-developed muscular structure in 3 patients (with recto-vaginal, cloacal and prostatic fistulas), absence of ...

1989-01-01

159

MRI in preoperative evaluation of chronic paranasal sinusitis - a comparison with CT  

International Nuclear Information System (INIS)

Purpose: To determine the value of MRI in the preoperative evaluation of chronic paranasal sinusitis and to compare the results with CT and intraoperative findings. Method/Materials: 42 patients with clinical signs of chronic paranasal sinusitis underwent MRI after CT evaluation on one day, with subsequent functional endoscopic sinus surgery on the next day. Coronary CT was obtained with 5-mm slices and table-feed in the prone position, while MRI was performed in the supine position with coronary T_2-TSE+pd and coronary and transverse HASTE, each with 5-mm slice thickness. Aquisition time in MRI was less than 8 minutes. Two radiologists reviewed the CT and MRI scans for signs of sinusitis and detection of anatomical landmarks. The results were correlated with the intraoperative findings. Results: MRI offered no artifacts of dental work and showed more often high quality pictures than ...

2001-04-01

160

Lipiodol-CT findings of hepatocellular carcinoma: Correlation with lipiodol accumulation pattern and serum AFP  

Energy Technology Data Exchange (ETDEWEB)

Early diagnosis of hepatocellular carcinoma (hepatoma) along with surgical resection is the most appropriate therapeutic modality. For this purpose, there have been many reports concerning the diagnostic value of Lipiodol-CT scan. The authors selected 45 patients with hepatoma during the period of Feb.1986 to Jan. 1988 who received a conventional CT scan, hepatic angiography and a Lipiodol-CT scan. The results were as follows: 1. There was no statistical significant between serum AFP level and mass size, morphology and amount of necrosis. 2. Tumor necrosis was observed in a single massive and multinodular type when the tumor size exceeded 5 cm. 3. Pattern II on Lipiodol-CT, homogenous accumulation of Lipiodol except for the area of inner necrosis, was most frequently demonstrated, which means that a tumor mass with hypervascularity and increased blood flow will attract Lipiodol better. 4. ...

1989-12-15

161

CT appearances of unilateral cleft palate 20 years after bone graft surgery  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To describe CT appearances in patients with unilateral cleft lip and palate (CLP) 20 years after bone graft surgery. Material and Methods: Eighteen consecutive patients with unilateral CLP were examined. All patients had been treated with primary closure, both in infancy and early childhood, supplemented with bone grafting at the age of around 10 years. The CT examination of the upper jaw included a dental CT program. The CT appearances of the cleft side were compared with those of the untreated non-cleft side. Results: Abnormal CT appearances included skew nasal aperture (n=17), nasal septal deviation (n=17), low floor of nasal aperture (n=15) at or towards the cleft side, and deviation of anterior nasal spine towards the non-cleft side (n=18). The posterior part of the bone cleft was visible in all patients, and the dental arch was V-shaped in 8. Conclusion: Although ...

2002-11-01

162

CT appearances of unilateral cleft palate 20 years after bone graft surgery  

International Nuclear Information System (INIS)

Purpose: To describe CT appearances in patients with unilateral cleft lip and palate (CLP) 20 years after bone graft surgery. Material and Methods: Eighteen consecutive patients with unilateral CLP were examined. All patients had been treated with primary closure, both in infancy and early childhood, supplemented with bone grafting at the age of around 10 years. The CT examination of the upper jaw included a dental CT program. The CT appearances of the cleft side were compared with those of the untreated non-cleft side. Results: Abnormal CT appearances included skew nasal aperture (n=17), nasal septal deviation (n=17), low floor of nasal aperture (n=15) at or towards the cleft side, and deviation of anterior nasal spine towards the non-cleft side (n=18). The posterior part of the bone cleft was visible in all patients, and the dental arch was V-shaped in 8. Conclusion: Although ...

2002-11-01

163

Evaluation of the hemodynamics of the femoral head compared with the ilium, femoral neck and femoral intertrochanteric region in healthy adults. Measurement with positron emission tomography (PET)  

International Nuclear Information System (INIS)

Non-traumatic osteonecrosis of the femoral head (ONF) is considered to be a disease that occurs primarily due to ischemia of the femoral head, while its etiology and pathology are not fully understood. It is therefore necessary to identify the characteristics of the hemodynamics of the femoral head. In this study, the hemodynamics in the ilium and proximal regions of the femur, including the femoral head, was investigated using positron emission tomography (PET). The subjects of this study consisted of 8 hip joints of four healthy male adults and 3 hip joints on the contralateral side of a femoral neck fracture, avulsion fracture of the greater trochanter and coxarthrosis (1 case each, all females) for a total of 11 hip joints of 7 subjects. The ages of the subjects ranged from 25 to 87 years (average age: 54 years). Blood flow was measured by means of the H_2"1"5O dynamic study method and blood volume ...

2005-10-01

164

Multiphasic helical CT of hepatocellular carcinoma. Evaluation after chemo embolization  

International Nuclear Information System (INIS)

The main purpose of this work is to report the personal experience with addition of contrast-enhanced multiphase helical CT to unenhanced CT (Lipiodol CT) in the evaluation of patients with hepatocellular carcinoma treated with chemoembolization and to analyze the present role of oily agent CT. It has been retrospectively reviewed the examinations of 42 consecutive patients submitted to globla chemoembolization over a 2-year period. CT was performed 18-30 days after the treatment. The Lipiodol CT study was carried out with volume acquisitions. It has been considered as nodules all well-defined areas with dense oily agent uptake; uptake itself was classified as: 0=absent, I=lower tha 10% of the tumor volume; II=lower than 50%, III=50%, IV=homogeneous. Contrast-enhanced helical CT was performed with the 2-phase technique in 28 patients and ...

2000-06-01

165

Waste characterization study for the Kemp's Ridley sea turtle. Technical memo  

Energy Technology Data Exchange (ETDEWEB)

The Kemp's Ridley sea turtle, Lepidochelys kempi, is an endangered species. The National Marine Fisheries Service's Head Start program is part of an international operation to save the turtles from extinction. Under the Head Start program, eggs from the Ridley's only known wild nesting beach at Rancho Nuevo in Mexico are transported to Padre Island on the Texas coast to be hatched. The head start enables the turtles to develop a survival advantage. The principal objective was to develop baseline waste-characterization data required to design a waste-water treatment scheme for the Galveston Head Start facility. As a secondary objective, preliminary testing of some filtration components was undertaken to determine which units were most appropriate for inclusion in a wastewater treatment scheme.

1988-02-01

166

COAST and MRO to Join Forces  

Science.gov (United States)

Cambridge scientists in the late 1980's. This same team, then headed by Professor John Baldwin, built the world's first separated-element optical/infrared aperture synthesis...

2011-09-15

167

A Role for the Army Medical Specialist Corps in Nation ...  

Science.gov (United States)

... in MEDCAP "the level of interface was left up ... of these patients had peripheral nerve injuries, head ... with poorly constructed prosthesis or waiting for ...

1993-04-13

168

Lacrimal gland masses on CT and MRI: a report of four cases; Raumforderungen der Traenendruese in CT und MRT am Beispiel von vier Faellen  

Energy Technology Data Exchange (ETDEWEB)

In an extended case report, we discuss four cases with masses in the lacrimal fossa representing the most important entities in this region (lymphoma, pleomorphadenoma, inflammatory pseudotumor, and malignant epithelial tumor). The different indications for CT and MRI are explained. For the differential diagnosis of lacrimal gland lesions, the following imaging parameters are important: The shape of the lacrimal gland, the inner structure, the degree of contrast enhancement, and the surrounding bony structures. In the evaluation of the expansion of lacrimal gland lesions, CT in thin slices with multiplanar reconstructions is equal to MRI. However, the contrast-enhancement of lacrimal glands is better evaluated with MRI than with CT. The bony structures are better visualized on CT than on MRI. (orig.) [Deutsch] In einem erweiterten Fallbericht wird ueber die vier grossen Entitaeten bei ...

1995-11-01

169

Role of positron emission tomography-computed tomography in staging and early chemotherapy response evaluation in children with neuroblastoma  

International Nuclear Information System (INIS)

To evaluate the role of positron emission tomography-computed tomography (PET-CT) in staging and determining early treatment response to chemotherapy in children with neuroblastoma (NB) and its correlation with the final outcome. Patients and Methods: Seventeen patients of NB with mean age of 51.5 months (age range 2-132 months; 14 males, 3 females) underwent serial "1"8F-fluorodeoxyglucose (FDG) PET-CT imaging. All 17 patients were for staging before any treatment. Twelve of 17 patients underwent "1"3"1I meta-iodobezylguanidine (MIBG) scan and bone scan. MIBG uptake was seen in the primary lesion in 11/12 patients. MIBG uptake in bones was seen in 3/12 patients. All bone lesions were concordant on MIBG and bone scan. Early response to chemotherapy was evaluated after two cycles using PET-CT. A 30% reduction in longest diameter was taken as cut-off value for response on CT based on the response ...

170

Update on well-baby and well-child care from 0 to 5 years  

Science.gov (United States)

AbstractOBJECTIVETo provide an overview of the 2009 edition of the Rourke Baby Record (RBR), which incorporates recent research in the literature relating to preventive health care for children aged 0 to 5 years.QUALITY OF EVIDENCERecommendations are identified as supported by good, fair, or consensus evidence, according to the classification of the Canadian Task Force on Preventive Health Care.MAIN MESSAGENew information and recommendations are given for growth monitoring, nutrition, developmental surveillance, physical examination maneuvers, immunization schedules, and advice for parents. Anticipatory guidance updates relate to injury prevention, infant swaddling, literacy facilitation, nonparental child care, parenting skills programs, serum lead levels, over-the-counter cough and cold medications, pacifiers, antipyretics, insect repellents, and dental care and oral health. The 2009 RBR is available in English and French in both National and Ontario versions and is endorsed by the ...

2010-12-01

171

TWENTE Study: The Real-World Endeavor Resolute Versus Xience V Drug-Eluting Stent Study in Twente: study design, rationale and objectives  

UK PubMed Central (United Kingdom)

Background. New-generation drug-eluting stents (DES) may solve several problems encountered with first-generation DES, but there is a lack of prospective head-to-head comparisons between...Full Text Available

2010-08-01

172

Plugging indicator for controlling the sodium quality. Indicateur de bouchage pour le controle de la qualite du sodium  

Energy Technology Data Exchange (ETDEWEB)

This device has and head-race pipe with an external part and a coaxial inner part. A measuring head is mounted movable between these 2 parts and has at least a thermocouple and a mobile grid for varying the section and the sodium flow to facilitate the impurities dissolution. This ensemble is completed by a longitudinal body containing the main parts of the indicator and surrounded by a thermal exchanger to cool the sodium.

1991-09-20

173

Experience with Aerosol Generation During Rotary Mode Core Sampling in the Hanford Single Shell Waste Tanks  

Energy Technology Data Exchange (ETDEWEB)

This document provides data on aerosol concentrations in tank head spaces, total mass of aerosols in the tank head space and mass of aerosols sent to the exhauster during Rotary Mode Core Sampling from November 1994 through June 1999. A decontamination factor for the RMCS exhauster filter housing is calculated based on operation data.

2000-01-24

174

Evaluation in femoral neck fracture scintimetry: modes of region of interest selection and influence on results  

Energy Technology Data Exchange (ETDEWEB)

Different sized ROIs within the femoral head and different modes of calculation were used in (/sup 99m/Tc)MDP scintimetry after femoral neck fracture. In preoperative scintimetry, correction for increased trochanteric uptake gave the best discrimination, whereas in postoperative scintimetry the direct ratio fractured/intact femoral head was superior. The change in ROI size had little influence.

1985-04-01

175

Device for marking and searching for information on a magnetic carrier  

Science.gov (United States)

A device for marking and searching for information on a magnetic carrier is described. In order to increase the noise immunity and reliability of the data recording and reading paths, the recording head is included between the amplifier of the clock pulses for the master oscillator and through the amplifier of the code pulses for the logical element unit. The reproduction head is connected through the code pulse shaper-amplifier with a switch which is connected with the display unit, and through another analogous clock pulse amplifier with a multivibrator.

1984-03-01

176

Crab crossing in a gamma-gamma collider  

International Nuclear Information System (INIS)

The crabbing of an incident photon beam from a laser, and the electron beam with which it interacts at the conversion point, is shown to have the same efficiency as in head-on Compton scattering, but with the advantages of a crossing geometry. The resulting #gamma#-ray beam is also crabbed, which allows for a crossing collision point, while maintaining the luminosity at the same value it would have in a head-on collision.

1994-03-28

177

Crab crossing in a Gamma-Gamma collider  

Energy Technology Data Exchange (ETDEWEB)

The crabbing of an incident photon beam from a laser, and the electron beam with which it interacts at the conversion point, is shown to have the same efficiency as in head-on Compton scattering, but with the advantages of a crossing geometry. The resulting {gamma}-ray beam is also crabbed, which allows for a crossing collision point, while maintaining the luminosity at the same value it would have in a head-on collision. ((orig.)).

1995-02-01

178

Crab crossing in a Gamma-Gamma collider  

International Nuclear Information System (INIS)

The crabbing of an incident photon beam from a laser, and the electron beam with which it interacts at the conversion point, is shown to have the same efficiency as in head-on Compton scattering, but with the advantages of a crossing geometry. The resulting #gamma#-ray beam is also crabbed, which allows for a crossing collision point, while maintaining the luminosity at the same value it would have in a head-on collision. ((orig.)).

179

Accurate positioning for head and neck cancer patients using 2D and 3D image guidance  

UK PubMed Central (United Kingdom)

Our goal is to determine an optimized image-guided setup by comparing setup errors determined by two-dimensional (2D) and three-dimensional (3D) image guidance for head and neck cancer (HNC)...Full Text Available

180

A tube inspection device. Dispositif de controle de tubes  

Energy Technology Data Exchange (ETDEWEB)

The device, aimed at non destructive control of the inner side of tubes such as steam generator tubes, is composed of a control sensor mounted on a support; the sensor head may rotate in the tube and a measuring system and signal processing allow for the exact determination of the angular position of the sensor head (application to ultrasonic or eddy current probes).

1993-05-07

181

Thin-Section CT findings of lung small peripheral adenocarcinoma detected by CT physical examination  

Energy Technology Data Exchange (ETDEWEB)

Subjects were 18 cases with adenocarcinoma of 20 mm or less in diameter, which were detected and resected surgically from September, 1993 to August, 1998. On these cases, thin-Section CT (TSCT) images were compared with pathological findings. Patients were 15 men and 3 women, with mean age of 63.4-year-old. An average tumor size was 11.5 mm (5-17 mm). According to pathological classification of Noguchi, type A as in 6 cases, type B in 3, type C in 7 and type F in 2. TSCT was carried by vas voltage =150 kVp, vas current =200 mA, beam width =2 mm, WW =2000 HU, and WL =-700 HU. The ratio of CT attenuation value in cancer by TSCT correlated with the ratio of aeration rate in the pathologic specimen. The cases of 30% or less on the ratio of CT attenuation value were 100% in types A and B, and 71% in type C. These results suggested that it is necessary to devide into two type in group of type C and the ratio of ...

1999-11-01

182

High resolution Computed Tomography in the study of temporal bone trauma  

International Nuclear Information System (INIS)

Thirty-five patients with temporal bone fractures were examined; the fractures were sometimes associated with dislocation of the assicular chain caused by road fatalities. Computed Tomography (CT) was performed either because of the presence of clinical symptoms associated with trauma of the temporal bone, because of a hemotympanum discovered during a CT scan of the brain. Thirty-three fractures were detected: 19 longitudinal, 6 transverse, and 8 complex. An incudostapedial dislocation was also detected, together with a displacement of a stapedial prosthesis from the lenticular process of incus, and 3 incus-malleus dislocation associated with fractures. High resolution CT allows the precise definition of the course of the fractures, of the associated dislocation of the ossicular chain, and of facial nerve lesion, thus allowing a more accurate surgical intervention. In the examination of the temporal bone, high resolution ...

1988-01-01

183

Effect of pressure on iodine complexes, 2  

International Nuclear Information System (INIS)

Absorption spectra of the CT bands of I_2 complexes with Et_2O, Et_2S, and Et_2Se in heptane have been measured up to 4400 bar at 25"0C. The equilibrium constants and the volume changes accompanying complex formation, and the molar extinction coefficients and absorption maxima have been estimated. The volume changes were comparable with those estimated by the visible I_2 bands and by the X-ray data of the I_2 complexes in the crystalline state. In the CT bands of Et_2S-I_2 and Et_2Se-I_2 complexes inversion of shift from red to blue has been observed with increasing pressure though the CT band of Et_2O-I_2 complex shifted only through red. This inversion appears to be characteristic of the strong CT complex. Enhancement of the molar extinction coefficient of the CT band has been found with increasing pressure suggesting enhancement of the CT interaction between ...

1979-01-01

184

Computed tomography (CT) in renal trauma  

International Nuclear Information System (INIS)

CT scans were performed on 25 patients suspected of sustaining ranal trauma. The utility of CT in both detecting renal damage and appraising the gravity of injuries was assessed. Nowadays, in fact, nephrectomy or reserved for lesions devastanting the kidney parenchyma or rupturing the renal pedicle; so it is very important to identyfy both the purposes of a better planned therapeutic approach. CT does both, being more accurate than urography in the detection of renal fractures, intra or extraparenchymal hematomas and contrast media extravasation. Urography very often shows aspecific lesion patterns and sometimes it is also falsely negative. In the present series CT was more reliable than angiography itself, particulary in the diagnosis of extra-renal hematic collections, contrast media extravasation and injuries to the other abdominal organs. Although CT may arouse the suspicion of ...

1987-01-01

185

Computed Tomography in staging and follow-up of thoracic Hodgkin's diseases  

International Nuclear Information System (INIS)

As yet, the role of Computed Tomography (CT) as a routine imaging technique in the staging and follow-up of thoracic Hodgkin's disease has not been assessed. The authors reported the results obtained in 120 patients affected with thoracic Hodgkin's disease, staged and followed by means af chest X-rays and CT. CT better identified intrathoracic involvement of mediastinal nodes, of lung parenchyma, of pleura, and of pericarcial and chest walls in 54/120 patients (45%), with staging modifications in 18 (15%) of them only. Treatment was changed only in 12 patients (19%) where radiation therapy had been planned. The clinical value of the additional information yielded by CT was especially evident in the follow-up: CT allowed the correct evaluation of persistent/ recurrent disease in 51/117 patients (43.5%), a figure high enough to suggest the use of CT in the routive ...

1990-01-01

186

Computed Tomography in pulmonary cystic fibrosis  

International Nuclear Information System (INIS)

This study was aimed at evaluating CT sensitivity in identifying the signs of pulmonary cystic fibrosis (CF). The chests of 39 patients (16 males and 23 females, mean age 19.1 years) were examined by CT: all patients had been given a clinical score according to Schwachman and Kulckzycki criteria. Thickened bronchial walls were observed in all cases, which are typical of peribronchitis. Bronchiectases were present in 87% of cases; their extent, pattern and localization were exactly shown on CT scans. Bronchoceles were seen on CT scans in 64% of patients; less frequent was the finding of atelectases and subpleural bullous emphysema. In a great number of patients (64% and 82%, respectively) pleural thickening and hilar adenopathy were demonstrated on CT scans. In conclusion, our results confirm CT as a more sensitive method than conventional radiography to identify ...

1991-01-01

187

CT of blunt chest trauma in children  

Energy Technology Data Exchange (ETDEWEB)

While trauma is still the leading cause of death in the pediatric age range, it is surprising how little the CT appearances of pediatric chest injury have been investigated in the literature. We have reviewed the CT findings of blunt chest trauma in 44 children for whom chest CT examinations were requested to investigate the extent of intrathoracic injury. We noted a propensity for pulmonary contusions to be located posteriorly or posteromedially, and for them to be anatomically nonsegmental and crescentic in shape. This is possibly attributable to the relatively compliant anterior chest wall in children. The CT appearances of other major thoracic injuries are described, including pulmonary lacerations, pneumothoraces, malpositioned chest tubes, mediastinal hematomas, aortic injury, tracheobronchial injury, hemopericardium, and spinal injuries with paraspinal fluid collections. Children demonstrating ...

1993-03-01

188

Prognostic precision in postoperative /sup 99m/Tc-MDP scintimetry after femoral neck fracture  

Energy Technology Data Exchange (ETDEWEB)

A 2-year follow-up regarding healing complications, such as redisplacement, nonunion, and segmental collapse of the femoral head, was performed in 306 patients operated on for femoral neck fracture and examined with /sup 99m/Technetium-MDP scintimetry within 2 weeks postoperatively. Scintimetric evaluation was performed by selecting regions of interest over the femoral head on the fracture side and the intact side and by comparing the uptake. A femoral head ratio fractured/intact side thus was obtained. Of 199 patients with an intact femoral head uptake (ratio less than or equal to 1.0), 181 showed no signs of healing complications at 2 years, whereas 18 had developed healing complications. Of 107 cases with a deficient femoral-head uptake (ratio < 1.0), 96 had developed healing complications within 2 years from the operation, while 11 cases had no signs of radiographic ...

1987-01-01

189

Prognostic precision in postoperative "9"9"mTc-MDP scintimetry after femoral neck fracture  

International Nuclear Information System (INIS)

A 2-year follow-up regarding healing complications, such as redisplacement, nonunion, and segmental collapse of the femoral head, was performed in 306 patients operated on for femoral neck fracture and examined with "9"9"mTechnetium-MDP scintimetry within 2 weeks postoperatively. Scintimetric evaluation was performed by selecting regions of interest over the femoral head on the fracture side and the intact side and by comparing the uptake. A femoral head ratio fractured/intact side thus was obtained. Of 199 patients with an intact femoral head uptake (ratio #<=# 1.0), 181 showed no signs of healing complications at 2 years, whereas 18 had developed healing complications. Of 107 cases with a deficient femoral-head uptake (ratio < 1.0), 96 had developed healing complications within 2 years from the operation, while 11 cases had no signs of radiographic complications. We conclude ...

190

Femoral head vitality after intracapsular hip fracture  

International Nuclear Information System (INIS)

Femoral head vitality before, during and at various intervals from the operation was determined by tetracycline labeling and/or _9_9 sp (m)Tc-MDP scintimetry. In a three-year follow-up, healing prognosis could be determined by scintimetry 3 weeks from operation; deficient femoral head vitality predicting healing complications and retained vitality predicting uncomplicated healing. A comparison between pre- and postoperative scintimetry indicated that further impairment of the femoral head vitality could be caused by the operative procedure, and as tetracycline labeling prior to and after fracture reduction in 370 fractures proved equivalent, it was concluded that the procedure of osteosynthesis probably was responsible for capsular vessel injury, using a four-flanged nail. The four-flanged nail was compared with a low-traumatic method of osteosynthesis, two hook-pins, in a prospective randomized 14 month study, and the ...

2010-06-01

191

Femoral head viability following hip fracture. Prognostic role of radionuclide bone imaging  

Energy Technology Data Exchange (ETDEWEB)

A retrospective study was made of all radionuclide (RN) bone images performed at our institution over a two-year period to evaluate femoral head viability after nonpathologic fracture of the femoral neck. Twelve patients had avascular femoral heads during the perioperative period, of which nine had adequate follow-up. Seven of these nine patients had follow-up bone images. Revascularization occurred in four patients, while three had persistent absence of femoral head uptake. With clinical follow-up ranging from four to 29 months (median: 14 months), only two of these nine patients developed clinical or radiographic evidence of osteonecrosis. RN bone imaging performed in the perioperative period does not reliably predict the development of post-traumatic osteonecrosis of the femoral head and, at present, should not be used to determine prospectively method of treatment of femoral neck fracture.

1985-03-01

192

Femoral head viability following hip fracture. Prognostic role of radionuclide bone imaging  

International Nuclear Information System (INIS)

A retrospective study was made of all radionuclide (RN) bone images performed at our institution over a two-year period to evaluate femoral head viability after nonpathologic fracture of the femoral neck. Twelve patients had avascular femoral heads during the perioperative period, of which nine had adequate follow-up. Seven of these nine patients had follow-up bone images. Revascularization occurred in four patients, while three had persistent absence of femoral head uptake. With clinical follow-up ranging from four to 29 months (median: 14 months), only two of these nine patients developed clinical or radiographic evidence of osteonecrosis. RN bone imaging performed in the perioperative period does not reliably predict the development of post-traumatic osteonecrosis of the femoral head and, at present, should not be used to determine prospectively method of treatment of femoral neck fracture.

193

The value of computed tomography in the diagnosis of grating scapula  

Energy Technology Data Exchange (ETDEWEB)

Snapping or grating scapula is a condition of the shoulder girdle in which the patient complains of pain and an audible snapping sound which may be associated with pain. We evaluated the diagnostic value of the computed tomography (CT) scans using the clinical diagnosis of a grating scapula as the gold standard. This retrospective study reports the sensitivity, specificity, likelihood ratio and receiver operator characteristic curve for the CT scans and the k value as a measure of the interobserver agreement. None of the parameters validated the examination. We therefore concluded that CT scans are inappropriate for differentiation between a grating scapula and a normally functioning shoulder except in cases where bony abnormalities are present. (orig.)

1994-07-01

194

Synovial cysts of the lumbar spine: CT and MRI correlations  

Energy Technology Data Exchange (ETDEWEB)

Intraspinal synovial cysts were diagnosed in six patients during a 5-year period and retrospectively studied. Plain films of the lumbar spine showed degenerative changes in all patients. Lumbar myelography showed a posterior and lateral defect caused by extradural compression. Using CT without contrast enhancement established the diagnosis in five of the six patients. In four cases MRI was performed, three before and after injection of gadolinium diethyline-triamine penta-acetic acid (Gd-DTPA). Including the patient with a false-negative CT, MRI was positive in all patients. (orig.)

1994-08-01

195

Spiral CT with three-dimensional and multiplanar reconstruction in the diagnosis of anterior chest wall joint and bone disorders  

Energy Technology Data Exchange (ETDEWEB)

Twenty-seven patients with symptoms or clinical findings suggesting joint or bone disorders of the anterior chest wall (ACW) were evaluated by spiral CT with 3-dimensional (3-D) and multiplanar reconstructions. Preceding conventional ACW tomography was performed in 10 patients. ACW joint and bone changes were visualized more adequately by coronal 2-D reconstructions based on spiral CT than by conventional tomography. In addition, nonossified costal cartilages and soft tissue lesions were demonstrated. 3-D reconstructions sometimes added information, especially in patients with fracture and dislocation. (orig.).

1994-09-01

196

Phase- and size-adjusted CT cut-off for differentiating neoplastic lesions from normal colon in contrast-enhanced CT colonography  

Energy Technology Data Exchange (ETDEWEB)

A computed tomography (CT) cut-off for differentiating neoplastic lesions (polyps/carcinoma) from normal colon in contrast-enhanced CT colonography (CTC) relating to the contrast phase and lesion size is determined. CT values of 64 colonic lesions (27 polyps <10 mm, 13 polyps {>=}10 mm, 24 carcinomas) were determined by region-of-interest (ROI) measurements in 38 patients who underwent contrast-enhanced CTC. In addition, the height (H) of the colonic lesions was measured in CT. CT values were also measured in the aorta (A), superior mesenteric vein (V) and colonic wall. The contrast phase was defined by xA + (1 - x)V using x as a weighting factor for describing the different contrast phases ranging from the pure arterial phase (x=1) over the intermediate phases (x=0.9-0.1) to the pure venous phase (x=0). The CT values of the lesions were correlated ...

2004-12-01

197

Ovarial tumours in the CT image - correlation of histology and CT diagnosis  

Energy Technology Data Exchange (ETDEWEB)

The value of CT in respect of preoperative determination of tumour status and of tumour classification was studied using 127 histologically identified ovarial tumours as basis in a blind study via mutual image classification by the two participating institutes. The medium accuracy of diagnosis was 82%, but the results were found to be greatly dependent on tumour histology. Quotas of more than 90% were obtained in case of functional cysts, cystomas, cystadeno-carcinomas and dermoids, whereas classification was less successful with the other types of tumours such as germ cell tumours, tumours of the sexually differentiated stroma, metastases and tubo-ovarial abscesses.

1984-04-01

198

Integration of SPECT with CT to plan radiotherapy fields. n application to conformal irradiation for lung carcinoma  

International Nuclear Information System (INIS)

Single photon emission computed tomography (SPECT) of lung perfusions permits to map functioning lung parenchyma with higher sensitivity than CT. Delivering higher radiations doses it used to increase local control in lung carcinoma; this strategy is based on radiobiological and clinical studies. Lung parenchyma is a dose-limiting tissue in patients irradiated for lung cancer. Functional mapping based on SPECT and CT findings permits to design radiation beams such as to minimize irradiation of functioning lung.

1999-04-01

199

Dentascan CT of mandibular incisive canal. Radiological anatomy and therapeutic implications  

International Nuclear Information System (INIS)

The main purpose of this paper is to stress the importance of CT depiction of the mandibular incisive canal. This anatomical structure contains a major neurovascular bundle and is thus very important in the planning of mandibular implants in the canine-incisive area. The importance of careful assessment of the mandibular canal course before implantology is now widely recognized. The same holds true for the canine-incisive region in the jaw, to detect the incisive canal if present and prevent any complications from its accidental damage. CT with a dedicated software showed the incisive canal in a large number of patients, which calls for precise reporting of its presence, course, and relationships with teeth.

1999-11-01

200

CT findings of foreign bodies in the chest: a pictorial essay  

Energy Technology Data Exchange (ETDEWEB)

The most common causes of tracheobronchial foreign bodies are peanuts in children, and meat and dentures in adults. The most common causes of esophageal foreign bodies are coins in children and meat in adults. It is passable to diagnose a foreign body by visualization on a chest radiograph, if the foreign bodies are radio opaque. However, if the foreign bodies are radiolucent and the patients do not remember the history of aspiration, it is important to evaluate CT findings for foreign bodies and their complications. We describe the CT findings of various thoracic foreign bodies in children and adults.

2008-05-15

201

Development of Guide System for a Reactor Head Maintenance Robot  

Energy Technology Data Exchange (ETDEWEB)

The Control Rod Drive(CRD) nozzles for PWR nuclear power plants(NPP) house the control rod drives. The number of nozzle penetrations range from the mid-30's to over 100 in each reactor head. The integrity of CRD nozzles is very important, because the primary pressure boundary is established with the J-groove weld joining the nozzle to the head clad surface. The Alloy 600 PWSC CRD nozzle leaks discovered in the fall of 2000 and spring of 2001 in several US plants. Therefore the NRC has recommended a more proactive effort by US utilities to inspect similarly susceptible nozzles in all US plants. The primary safety concern is circumferential cracks that can permit the nozzles to separate from the head at high velocity and produce a large-break leak in the reactor vessel. A secondary concern is head leakage from any through-wall cracks in the nozzle or J-groove weld area. Numerous inspection and ...

2005-07-01

202

The effect of patient positioning aids on PET quantification in PET/MR imaging  

British Library Electronic Table of Contents (United Kingdom)

Objectives Clinical PET/MR requires the use of patient positioning aids to immobilize and support patients for the duration of the combined examination. Ancillary immobilization devices contribute to overall attenuation of the PET signal, but are not detected with conventional MR sequences and, hence, are ignored in standard MR-based attenuation correction (MR-AC). We report on the quantitative effect of not accounting for the attenuation of patient positioning aids in combined PET/MR imaging. Methods We used phantom and patient data acquired with positioning aids on a PET/CT scanner (Biograph 16, HI-REZ) to mimic PET/MR imaging conditions. Reference CT-based attenuation maps were generated from measured (original) CT transmission images (origCT-AC). We also created MR-like attenuation map...

2011-01-01

203

Structure and Characterization of Nicotinic Acetylcholine ...  

Science.gov (United States)

... the ct-neurotoxin from Dendroaspis viridis venom (a-DTX) , which binds to four sites on the AcChR molecule (Conti-Tronconi & Raftery 1986). ...

1991-11-07

204

Paroxysmal nocturnal hemoglobinuria: a case report of MR, CT findings  

Energy Technology Data Exchange (ETDEWEB)

Paroxysmal nocturnal hemoglobinuria (PNH) is a rare, acquired disease involving multiple hematopoietic cell lines. Characteristics of PNH are intrinsic hemolytic anemia, iron deficiency anemia and venous thrombosis. We report a case of PNH with characterostoc MR and CT findings. The signal intensity of renal cortex was lower than that of medulla on both T1-and T2-weighted MR imaging. On T2 weighted MR images, the liver showed very low signal intensity but the signal intensity of the spleen was normal. On precontrast CT the attenuation of renal cortex was higher than that of renal medulla and the attenuation of liver was higher than that of the spleen. These findings of MR imaging and CT were the result from the deposition of hemosiderin in the cells of proximal convoluted tubules and transfusional hemosiderosis of liver.

1995-10-15

207

Identification and staging of bladder carcinoma  

International Nuclear Information System (INIS)

The purpose of the present study was to compare the effectiveness of MRI, CT and radioimmunoscintigraphy in the staging and detection of bladder cancers in 28 patients. We distinguish two groups: Group I included the tumour stages CIS-T_3_A and the second group the deep infiltrative tumours T_3_B-T_4. MRI was slightly superior to CT in respect of tumour staging (75% correct results as compared to 63%). No understaging occurred with MRI, whereas in 22% of the cases the stage of the tumour was underestimated using CT diagnostics. Overstaging occurred in 25% of the MRI and 15% of the CT-diagnostics, respectively. RIS cannot distinguish the tumour groups, and hence this method is useful only for the detection of the primary tumour and metastases. In 77% of cases the tumour was detected and in 15% the tumour could be safely excluded. (orig.).

208

Estimated fetal radiation dose from multislice CT studies  

International Nuclear Information System (INIS)

It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.

209

Cardiac transplantation. Value of computed tomography  

International Nuclear Information System (INIS)

In 9 over 12 patients who underwent cardiac transplantation computed tomography was performed. In 5 of them CT was obtained also before the surgical treatment. In all patients angio-CT technique was performed, while the ECG-gated technique was employed only before surgery. CT shows changes in morphology of both atria but over all of the right one, and rotation of the heart on the longitudinal axis. The conditions of the pericardium are particulary well demonstrated: in 5 cases pericardial effusion was observed, 3 times localized and 2 times diffuse. Only in 1 patient a small thrombus in the right atrium was demonstrated. CT allows the possibility to obtain simultaneously information on mediastinum, lung and pleura. Pleural effusion, pulmonary infections and mediastinal complications are easily demonstrated.

1986-01-01

210

COBAS AMPLICOR CT/NG Test for Neisseia gonorrhoeae Package Insert  

Science.gov (United States)

... The thermostable Thermus aquaticus DNA polymerase, (Taq pol), in the presence of excess deoxynucleoside triphosphates (dNTPs), including deoxyadenosine ...

211

CF findings of bowel infarction in 56 surgical patients, 5 of whom with reversible ischemia  

International Nuclear Information System (INIS)

Bowel infarction is a rare and typical condition of the elderly; despite improvements in diagnostic imaging and vascular surgery, bowel infarction remains a major cause of acute abdomen, with mortality rates ranging 70-80%. Diagnosis on often late because clinical sings, laboratory data and radiologic findings are a specific. The authors investigated radiographic and particular CT patterns of intestinal infraction in 56 patients submitted to surgery within 12 hours of admission. We also report the CT findings of 5 of these patients who had reversible mesenteric ischemia. CT is more sensitive than radiography and does not exhibit the limitations of angiography (i.e., invasiveness, radiation exposure an complex organization. Therefore CT can presently be considered the method of choice in patients with suspected bowel infarction.

1999-04-01

212

CT in the study of thoracic-pulmonary complications after liver transplantation  

International Nuclear Information System (INIS)

In this article is reviewed the role of Computed Tomography (CT) in thoracic complications following ortho topic liver transplantation (OLT). In a post-OLT population of 567 patients transplanted in the Italian institutions, 100 patients (17.6%) were examined with chest CT. It was reviewed data relative to the total number of examinations, clinical and/or radiographic indications, the CT technique-i.e., conventional (with (out) intravenous, i.v., contrast material) or high-resolution (HRCT). It also reviewed the radiologic patterns and their correlation with the other clinical, bronchoscopic and/or laboratory results. Of 152 chest CT examinations, 45 (29.6%) were performed because of clinical indications, 31 (20.4%) because of a radiographic abnormality, 64 (42.1%) because of clinical and radiographic abnormality, 64 (42.1%) because of clinical and radiographic indications, while in 12 cases (7.9%) the ...

2000-12-01

213

Aortic non communicating dissections. A study with helical CT  

International Nuclear Information System (INIS)

The evaluate the signs of aortic intramural hematoma with helical CT and the diagnostic role of this technique in patients with this condition. It was reviewed the CT findings of 396 patients submitted to emergency examinations for suspected aortic dissection from 1995 to 1999. Only 18 patients (6 women and 12 men) had CT signs of aortic intramural hematoma. Helical CT studies were carried out with the following parameters: slice thickness 10 mm, reconstruction index 10, feed 1.5 mm, conventional algorithm with minimum values of 130 kV and 125mA. All patients were examined with dynamic contrast-enhanced CT, before and after a power injection of 130 mL ionic contrast material. It was studied: hematoma localization and longitudinal extension; thickness and density of aortic wall; presence and location of intimal calcifications; integrity of intimal wall; hemo mediastinum and/or hemo ...

2000-09-01

214

Prognostic value of dynamic MRI in assessing post-traumatic femoral head vascularity  

Energy Technology Data Exchange (ETDEWEB)

The vascular status of femoral heads in the post-traumatic period of intracapsular femoral neck fracture (ICFNF) remains uncertain until the patient actually develops avascular necrosis (AVN). Several methods for predicting the viability of femoral head have been reported, that are not effective or widely used because of unreliability, potential complications, and technical difficulties. The present study involved the use of Dynamic MRI (DMRI) in assessing femoral head vascularity to predict AVN. The role of DMRI was studied prospectively in 30 patients with 31 ICFNF. Fractures were divided in to three types (Type A, B, or C) based on the femoral head vascularity shown by dynamic curve patterns on MRI evaluation. Type A was preserved vascularity, Type B was some decrease in vascularity but still viable while Type C was significantly reduced vascularity. These were followed-up for 6 months to 2 years to ...

2009-06-15

215

To study the role of dynamic magnetic resonance imaging in assessing the femoral head vascularity in intracapsular femoral neck fractures  

Energy Technology Data Exchange (ETDEWEB)

Intracapsular femoral neck fractures remain unsolved fractures even after improvement in techniques of diagnosis and internal fixation. Individuals who sustain displaced femoral neck fractures are at high risk of developing avascular necrosis and non-union. Although several methods for predicting the viability of femoral head have been reported, they are not effective or widely used because of unreliability, potential complications and technical difficulties. Dynamic MRI was introduced in the recent past as a simple, non-invasive technique to predict the femoral head viability after the femoral neck fractures. In this study role of dynamic MRI was studied in 30 patients with 31 intracapsular femoral neck fractures. Fractures were divided in to three types according to dynamic curve patterns on MRI evaluation and were followed up for 6 months to 2 years to observe the final outcome. Sensitivity, Specificity and the Accuracy of dynamic MRI in ...

2010-09-15

216

To study the role of dynamic magnetic resonance imaging in assessing the femoral head vascularity in intracapsular femoral neck fractures  

International Nuclear Information System (INIS)

Intracapsular femoral neck fractures remain unsolved fractures even after improvement in techniques of diagnosis and internal fixation. Individuals who sustain displaced femoral neck fractures are at high risk of developing avascular necrosis and non-union. Although several methods for predicting the viability of femoral head have been reported, they are not effective or widely used because of unreliability, potential complications and technical difficulties. Dynamic MRI was introduced in the recent past as a simple, non-invasive technique to predict the femoral head viability after the femoral neck fractures. In this study role of dynamic MRI was studied in 30 patients with 31 intracapsular femoral neck fractures. Fractures were divided in to three types according to dynamic curve patterns on MRI evaluation and were followed up for 6 months to 2 years to observe the final outcome. Sensitivity, Specificity and the Accuracy of dynamic MRI in ...

2010-09-01

217

Studies on scintigraphic findings after femoral head replacement  

Energy Technology Data Exchange (ETDEWEB)

Femoral head replacement was performed for femoral neck fracture or femoral head necrosis on 36 hips of 34 patients on whom Tc-99m MDP scintigraphy was done for analysis of radioisotope uptake around the prosthesis. In the cases with satisfactory clinical course after replacement surgery the uptake was high in the area between the prosthesis and the trochanter, in the area of the stem tip of the prosthesis and in the acetabular area. The high uptake decreased gradually and reached a normal level by 8 months after surgery. The cases with no decrease of high uptake by 8 months after surgery were considered to have had an eventful postoperative course associated with some complication such as infection, fracture, loosening etc. Tc-99m MDP scintigraphy was useful for early detection of complications and to evaluate progress of the operated patients. (author)

2001-03-01

218

Self-organization and electrical properties of Head-to-Tail poly(3-hexylthiophene) in Langmuir-Blodgett films  

Energy Technology Data Exchange (ETDEWEB)

The conductive ultra thin films were fabricated from mixed monolayers containing stearic acid and Head-to-Tail poly(3-alkylthiophene). These films exhibited well-defined layered structures as determined by optical absorption and X-ray diffraction measurements. The UV-Vis absorption spectra of these films showed lower energy absorption shifts of 48 nm from that of the random poly(3-alkylthiophene)/stearic acid LB films. The blue shift of absorption maximum of the LB film is attributed to the increase of {pi}-conjugation length caused by no steric hindrance of alkyl side chains. The conductivity of the Head-to-Tail poly(3-hexylthiophene)/stearic acid LB films was greatly improved in the range of 67-100 S/cm. (orig.)

1997-01-01

219

Modelling the tribology of thin film interfaces  

CERN Document Server

substrate). Within each group of simulations, three lubricant film thicknesses are studied to examine the effect of varying lubricant thickness. Statistical data are collected from each simulation and presented in this work. Via these data, together with the evolution, of atomic and molecular configurations, a very detailed picture of the properties of this thin film interface is presented. In particular, we conclude that perfluoropolyether lubricant forms distinct molecular layers when confined between two substrates, the rate of heat generation under shearing conditions typical of those in a head-disk interface is insufficient for thermal mechanisms to result directly in lubricant degradation, and mechanical stresses attained in the head-disk interface are unlikely to result in any significant degree of lubricant degradation. This thesis examines the tribology of a head-disk interface in an operating hard disk drive via ...

2000-01-01

220

Meeting report: A celebration of the work of Professor Tony Hart, Liverpool, United Kingdom, 7 March 2009  

British Library Electronic Table of Contents (United Kingdom)

Over 300 delegates participated in this scientific meeting to celebrate the career of the late Professor Tony Hart, who was Head of Department of Medical Microbiology, University of Liverpool, from 1986 until his death in September 2007. The meeting, which was opened by Professor James Stewart (Head, School of Infection and Host Defence, University of Liverpool) and closed by Professor Bernard Brabin (Head of the Child Health Group, Liverpool School of Tropical Medicine), captured some of the major elements that distinguished Tony Harts remarkable career. These included: broad research interests spanning both human and veterinary medicine; the ability to conduct both clinical and basic science research with equal skill and vigour; and his phenomenal mentorship of postgraduate students. Eac...

2010-01-01

221

Jet plume injection and combustion system for internal combustion engines  

Energy Technology Data Exchange (ETDEWEB)

This invention is comprised of an improved combustion system for an internal combustion engine is disclosed wherein a rich air/fuel mixture is furnished at high pressure to one or more jet plume generator cavities adjacent to a cylinder and then injected through one or more orifices from the cavities into the head space of the cylinder to form one or more turbulent jet plumes in the head space of the cylinder prior to ignition of the rich air/fuel mixture in the cavity of the jet plume generator. The portion of the rich air/fuel mixture remaining in the cavity of the generator is then ignited to provide a secondary jet, comprising incomplete combustion products which are injected into the cylinder to initiate combustion in the already formed turbulent jet plume. Formation of the turbulent jet plume in the head space of the cylinder prior to ignition has been found to yield a higher maximum combustion pressure in the ...

1992-12-31

222

Intake system for direct fuel injection diesel engine  

Energy Technology Data Exchange (ETDEWEB)

An intake system is described for a direct fuel injection diesel engine having a cylinder block, at least one cylinder in the cylinder block, a piston in the cylinder having a recess on a top surface thereof, a cylinder head mounted on the cylinder block on top of the cylinder, a fuel injector adapted to directly inject fuel into a combustion chamber formed between the lower side of the cylinder head and the recess on the top surface of the piston, and below the injector, and a single exhaust passage opening to the combustion chamber at a location near the injector, the intake system comprising first and second intake passages in the cylinder head, the first and second intake passages are independent of each other and adapted to introduce air into the combustion chamber. The controller means are coupled to the second intake passage for controlling the flow of air therethrough.

1987-08-25

223

Experience curves for feasibility studies and planning of modern low-head hydro turbines  

Energy Technology Data Exchange (ETDEWEB)

Results are presented of an extensive investigation of the characteristics of over two hundred low-head turbines manufactured all over the world that have been installed or are due to be installed in hydropower plants between 1953 and 1984. The research focused mainly on bulb turbines, with horizontal shaft arrangement and tubular turbines with their shafts either horizontal or inclined at an angle to the horizontal. The characteristics of the above mentioned type of turbines are presented in the form of statistical diagrams and regression equations suitable for preliminary design and feasibility studies of low-head hydro projects. Nomographs have been developed for displaying the relationships between the various turbine characteristics and comparing the important dimensions and parameters of turbines which have found common application in the hydropower technology. New simplified parametric ratio for selection of turbines have been developed ...

1982-12-01

224

Small lung neoplasms with growing attitude of alveolar lining. CT-pathologic correlation  

Energy Technology Data Exchange (ETDEWEB)

The article correlates CT and pathologic findings in 25 lung nodules with ground glass attenuation, which are small than 2 cm in diameter. They includes adenocarcinomas (Noguchi's classification type A, B, C) and a typical adenomatous hyperplasia. (author)

2000-01-01

225

Polyp measurement based on CT colonography and colonoscopy: variability and systematic differences  

Energy Technology Data Exchange (ETDEWEB)

To assess the variability and systematic differences in polyp measurements on optical colonoscopy and CT colonography. Gastroenterologists measured 51 polyps by visual estimation, forceps comparison and linear probe. CT colonography observers randomly assessed polyp size two-dimensionally (abdominal and intermediate window) and three-dimensionally (manually and semi-automatically). Linear mixed models were used to assess the variability and systematic differences between CT colonography and optical colonoscopy techniques. The variability of forceps and linear probe measurements was comparable and both showed less variability than measurement by visual assessment. Measurements by linear probe were 0.7 mm smaller than measurements by visual assessment or by forceps. The variability of all CT colonography techniques was lower than for measurements by forceps or visual assessment and sometimes lower (only ...

2010-06-15

226

Increased renal corticomedullary FDG activity in a patient of NHL-malignant or benign?  

International Nuclear Information System (INIS)

Authors describe diagnostic dilemma of differentiating pyelonephritis with lymphomatous involvement of kidney in a known case of lymphoma. FDG uptake pattern was non-discriminatory and pyelonephritis diagnosed retrospectively on follow up study. Authors emphasize the importance of recognition of features and subtle clues of infection evident on CT component of PET-CT. (author)

227

Current diagnosis of tumors developed in the internal auditory canal and cerebellopontine angle  

Energy Technology Data Exchange (ETDEWEB)

The introduction of CT scan and, more recently, magnetic resonance imaging, has radically changed the diagnostic approach to tumors developed in the internal auditory canal and cerebellopontine angle. CT scan with intravenous injection visualizes tumors lying in the cerebellopontine angle. Magnetic resonance imaging, especially using gadolinium, is a very accurate means for diagnosing tumors of both the auditory canal and cerebellopontine angle.

1988-10-13

228

Comparison of CT and MRI in patients with tibial plateau fracture: can CT findings predict ligament tear or meniscal injury?  

Energy Technology Data Exchange (ETDEWEB)

(1) To determine the accuracy of computed tomography (CT) in the evaluation of ligament tear and avulsion in patients with tibial plateau fracture. (2) To evaluate whether the presence or severity of fracture gap and articular depression can predict meniscal injury. A fellowship-trained musculoskeletal radiologist retrospectively reviewed knee CT and MRI examinations of 41 consecutive patients presenting to a level 1 trauma center with tibial plateau fractures. Fracture gap, articular depression, ligament tear and footprint avulsions were assessed on CT examinations. The MRI studies were examined for osseous and soft tissue injuries, including meniscal tear, meniscal displacement, ligament tear, and ligament avulsion. CT demonstrated torn ligaments with 80% sensitivity and 98% specificity. Only 2% of ligaments deemed intact on careful CT evaluation had partial or complete tears on ...

2007-02-15

229

Comparative accuracy of Computed Tomography and lymphoangiography in detecting lymph node metastases from epithelial cancer of the ovary  

International Nuclear Information System (INIS)

The accuracy is investigated of both lymphangiography and CT in detecting lymph nodes metastases in 59 patients evaluated preoperatively and subsequently submitted to surgery with selective/systemic pelvic and paraaortic lymphadenectomy. CT accuracy was also investigated in 46 patients with a clinically suspected relapse of ovarian cancer (verified by means of clinical and/or CT follow-up in 36 patients, by laparotomy in 7, by fine-needle biopsy in 1 and by necroscopy in the last 2). In the first group (previously untreated patients) the overall results in the pelvis were, respectively, for lymphangiography and CT: 94.9% vs 89.8% accuracy, 86.6% vs 60% sensitivity, 97.7% vs 100% specificity, and 92.8% vs 100%, 95.5% vs 88% positive and negative predictive values. In the paraaortic region the results were: 89.1% vs 86.5% accuracy, 73.3% vs 66.6% sensitivity, 100% specificity for both techniques, 100% ...

1991-01-01

230

CT imaging of a primary malignant mixed mullerian tumor arising from the peritoneum  

British Library Electronic Table of Contents (United Kingdom)

Primary peritoneal malignant mixed mullerian tumors are very rare. We report the case of a patient presenting with pain in the right upper quadrant of the abdomen and in whom the physical examination demonstrated a peritoneal mass. Computed tomography (CT) confirmed the presence of a mass, with invasion of adjacent organs.

2008-01-01

231

Assessment of arterial tumor vascularity in small hepatocellular carcinoma. Comparison between color Doppler ultrasonography and radiographic imagings with contrast medium: dynamic CT, angiography, and CT hepatic arteriography  

Energy Technology Data Exchange (ETDEWEB)

Hepatocellular carcinoma (HCC) is characterized by tumor vascularization from the hepatic artery. The objective of our work was to compare color Doppler ultrasonography (CDU), including power Doppler ultrasonography (PDU) with radiographic imagings with contrast medium in regard to the detection of the arterial tumor vascularity of small hepatocellular carcinomas (HCC). We examined 42 small HCC lesions 2 cm or less in diameter in 37 patients for arterial tumor vascularity by conventional CDU, PDU, dynamic computed tomography (dCT), digital subtraction angiography (DSA), and CT hepatic arteriography (CTA). Color images were detected in 25 (59.5%) and 28 (66.7%) of the 42 lesions with conventional CDU and PDU, respectively, and tumor vascularity was detected in 26 (61.9%) by dCT, 23 (54.8%) by DSA, and 29 (69.0%) by CTA. Tumor vascularity could be detected in 51.9% by PDU and CTA, more than by conventional CDU, ...

2000-10-01

232

Accuracy of single versus combined use of ultrasonography or computed tomography in the localization of parathyroid adenoma  

International Nuclear Information System (INIS)

Objective was to assess the accuracy of a single versus combined use of ultrasound (US) or computed tomography (CT) in the localization of diseased parathyroid glands. Forty-one patients with hyper-parathyroidism treated surgically between January 2000 to December 2005 at Jordan University Hospital, Amman, Jordan were included in this study. Preoperative ultrasonographic and CT findings were reviewed and compared to the intraoperative and pathologic diagnosis of diseased parathyroid glands. The mean age of patients was 46 years (range 16-70; 15 males and 26 females). Parathyroid adenoma was confirmed in 33 patients and hyperplasia of the parathyroid glands in 8 patients. Preoperative evaluation was carried out in 32 patients (CT scan) and in 23 patients (US). In 18 cases, the diagnosis of parathyroid disease was based on CT findings alone and in 9 patients the diagnosis was based on a single US finding. ...

233

Abdominal masses in the pediatric age. Characterization by CT guided fine needle aspiration biopsy  

International Nuclear Information System (INIS)

CT-guided fine needle aspiration biopsy (FNAB) is known to improve diagnosis of expansive abdominal lesions, especially relative to more invasive procedure like explorative laparotomy. FNAB in not commonly use in pediatric patients because of their poor collaboration and of associated risks. The authors investigated the feasibility of FNAB in the pediatric age.

1999-04-01

234

Modern imaging methods for diagnostic evaluation of tumors of the oropharynx and the oral cavity; Moderne bildgebende Methoden bei der Diagnostik von Tumoren des Oropharynx und der Mundhoehle  

Energy Technology Data Exchange (ETDEWEB)

Differentiating a benign from a malignant lesion by information such as density data, or signal intensities or echo gradients, is not possible with CT, nor MRI, nor ultrasonography. Only some lesions show characteristic signs. Inflammations cannot be difscriminated from malignant tumors. CTs of small tumors in particular are so poor in contrast that it is much more difficult to detect tumors or discriminate them from other lesions, as compared to MR images or ultrasonographs. CT does not detect surface tumors, but is more sensitive than MRI or US in detecting discrete cortical bone lesions. The same applies to small calcified tumors. MRI however is most sensitive in detecting tumor volumes in the yellow marrow, and is the best modality for evaluation of extraossal extension of tumors. CT yields better results than MRI if applied for simultaneous screening of lymph node metastases in the lower neck. MRI frequently is spoilt ...

1996-11-01

235

MRI in preoperative evaluation of chronic paranasal sinusitis - a comparison with CT; MRT in der praeoperativen Diagnostik der chronischen Sinusitis im Vergleich mit der CT  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To determine the value of MRI in the preoperative evaluation of chronic paranasal sinusitis and to compare the results with CT and intraoperative findings. Method/Materials: 42 patients with clinical signs of chronic paranasal sinusitis underwent MRI after CT evaluation on one day, with subsequent functional endoscopic sinus surgery on the next day. Coronary CT was obtained with 5-mm slices and table-feed in the prone position, while MRI was performed in the supine position with coronary T{sub 2}-TSE+pd and coronary and transverse HASTE, each with 5-mm slice thickness. Aquisition time in MRI was less than 8 minutes. Two radiologists reviewed the CT and MRI scans for signs of sinusitis and detection of anatomical landmarks. The results were correlated with the intraoperative findings. Results: MRI offered no artifacts of dental work and showed more often high quality pictures than ...

2001-04-01

236

Ganglioneuromas in childhood: MRI and CT characteristics; Ganglioneurome im Kindesalter: CT- und MRT-Charakteristika  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in ...

2000-05-01

237

Value of ultrasonography, Ct and MR imaging in the diagnosis of primary hyperparathyroidism  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate the significance of preoperative localization of abnormal parathyroid glands to the surgical outcome in patients with primary hyperparathyroidism. Material and Methods: Thirty-nine patients with primary hyperparathyroidism were studied preoperatively with US (39 patients), CT (30 patients) and MR imaging (18 patients). The overall diagnostic accuracy for US was 87%, CT 66% and MR 94%. In patients with a single parathyroid adenoma US was the most cost-effective localization technique with a detection rate of 96%. CT had a lower detection rate (78%) but was of particular value for fairly large ectopic adenomas in the root of the neck. MR imaging was a good confirmatory test (93%). In patients with multiple gland disease (primary hyperplasia and multiple adenomas), no single localization study alone was sufficient. Combination of all 3 studies, however, alerted the physician to the presence of disease in ...

1996-09-01

238

Modern imaging methods for diagnostic evaluation of tumors of the oropharynx and the oral cavity  

International Nuclear Information System (INIS)

Differentiating a benign from a malignant lesion by information such as density data, or signal intensities or echo gradients, is not possible with CT, nor MRI, nor ultrasonography. Only some lesions show characteristic signs. Inflammations cannot be difscriminated from malignant tumors. CTs of small tumors in particular are so poor in contrast that it is much more difficult to detect tumors or discriminate them from other lesions, as compared to MR images or ultrasonographs. CT does not detect surface tumors, but is more sensitive than MRI or US in detecting discrete cortical bone lesions. The same applies to small calcified tumors. MRI however is most sensitive in detecting tumor volumes in the yellow marrow, and is the best modality for evaluation of extraossal extension of tumors. CT yields better results than MRI if applied for simultaneous screening of lymph node metastases in the lower neck. MRI frequently is spoilt ...

239

Malignant pulmonary lesion. Possible causes of CT misdiagnosis; Possibilita' di falsi negativi nella diagnosi delle neoplasie polmonari con Tomografia Computerzzata  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this work is to describe the radiological appearance of overlooked malignant pulmonary lesions at CT and to analyze the reasons of misdiagnosis. Ten patient with pulmonary lesion (PML) overlooked at forst CT examination were selected among patients with lung cancer. Endobronchial location of the tumors and their small size were the most frequent causes of misdiagnosis of PML at chest CT in the series. However, a systematic evaluation of CT scans can reduce the percentage of missed lesions. [Italian] Scopo del presente lavoro e' di descrivere le caratteristiche radiologiche delle lesioni polmonari maligne non identificate con la Tomografia Computerizzata (TC) e definire le possibili cause di errore. Sono stati esaminato 10 pazienti con tumore polmonare. Le sedi endobronchiale e centrale nonche' le piccole dimensioni delle lesioni polmonari maligne rappresentano le cause ...

1999-06-01

240

Macromodular splenic tuberculosis in a medically-treated AIDS patient: diagnosis and management by CT  

International Nuclear Information System (INIS)

We used computerized tomography (CT) in the study of eight patients with macronodular splenic tuberculosis prior to the microbiological diagnosis. These patients underwent additional CT controls during and after tuberculostatic therapy. All the patients studed presented the acquired immunodeficiency syndrome (AIDS). Splenomegaly and numerosous round, hypodense lesions that showed no contrast uptake were found in all the subjects. Only three patients presented evidence of tuberculosis in plain radiography and/or chest X-ray. Two patients presented abdominal lymph nodes. None of them showed evidence of hepatic lesions or ascites. follow-up CT scans revealed a progressive reduction of the lesions, which eventually disappeared completely, and splenomegaly was considerably reduced. Anthough it is uncommon, we should suspect splenic involvement in tuberculosis if the clinical and radiological contexts are appropriate. ...

241

Lipiodol-CT in the detection of tumor persistence in hepatocellular carcinoma treated with percutaneous ethanol injection  

Energy Technology Data Exchange (ETDEWEB)

Our purpose was to investigate the usefulness of Lipiodol-CT for detection of residual viable neoplastic tissue in hepatocellular carcinoma (HCC) lesions treated by means of percutaneous ethanol injection (PEI). An emulsion of 5 to 20 ml iodized oil and 50 to 70 mg doxorubicin hydrochloride was intraarterially injected in 18 patients with 25 HCC lesions treated by means of PEI one to 24 months before. At CT performed 3 to 5 weeks after injection, retention of Lipiodol was observed in 9 of 13 tumors that still contained viable neoplastic tissue and in 2 of 12 tumors proven to have undergone complete necrosis after PEI. The sensitivity and specificity of Lipiodol-CT were 69.2% and 83.3%, respectively. Thus, Lipiodol-CT seems to have limited diagnostic value after PEI, probably as a consequence of the alcohol-induced vascular damage, accounting for both false-negative and false-positive results. (orig.).

1994-07-01

242

Intrahepatic cholangiocarcinoma : gross appearance and corresponding pathologic and radiologic features  

International Nuclear Information System (INIS)

To assess the clinical and pathologic features of each type of intrahepatic cholangiocarcinoma, which is divided into three types according to gross appearance, and to determine the efficacy of CT in detecting this tumor. The pathologic and CT features of 53 surgically proven cases of intrahepatic cholangio-carcinoma were reviewed. On the basis of their gross appearance, the tumors were divided into three types, as follows : mass forming (n=33), periductal infiltrating (n=6), and intraductal growth type (n=14). CT scans were analyzed for sensitivity of detection and correlation between a tumors appearance and its histopathology. The most common histopathologic feature of mass forming and periductal infiltrating type was tubular adenocarcinoma, while in the intraductal growth type, papillary adenocarcinoma (100%) was common. With regard to pattern of tumor spread, intrahepatic and lymph node metastasis were more common in ...

1999-05-01

243

Computed tomography of the orbit  

Energy Technology Data Exchange (ETDEWEB)

In less than a decade computed tomography (CT scanning) had a profound impact on diagnostic radiology. Radiology of the orbit is no exception. As early as 1973, reports published in the radiological literature indicated that this new noninvasive imaging method was a highly effective way of demonstrating intraorbital mass lesions. As CT scanners became widely available, computed tomography became a significant adjunct to ophthalmological diagnosis. Today the main indications for CT scanning of the orbit are: (1) suspected mass lesions, most frequently presenting as exophthalmos, (2) orbital trauma, including foreign bodies, (3) some congenital anomalies, and (4) suspicion of extension into the orbit of extraorbital disease processes. Along with ultrasonography, another new noninvasive imaging technique, CT has replaced a number of more invasive and often less effective diagnostic methods, such as orbital ...

1981-01-01

244

Comparative evaluation of US, CT and MR imaging in the diagnosis of hepatocellular carcinoma in cirrhotic patients  

International Nuclear Information System (INIS)

The contribution of US, CT and MR imaging was investigated in 25 cirrhotic patients with hepatocellular carcinoma. The following parameters were considered: lesion detection, site and size of the lesion, daughter nodules, location and/or infiltration of intrahepatic vessels, patency of portal vein and collateral vessels, signs of chronic liver disease, steatosis, ascitis, and lymphadenopathy. The results confirm the value of US, which also allowed lesion biopsy in all cases. CT was as accurate as US in detecting the lesion and even superior in demonstranting daughter nodules. MR imaging, with conventional SE and IR sequences, was inferior since it missed 3 lesions due to motion artifacts; more over, a smaller number of daughter nodules was seen than with CT. The authors conclude that, at present, MR imaging cannot replace US and CT; the latter, if combined with artheriography, using either hidrosoluble ...

1991-01-01

245

Atelectasis on pediatric chest CT: comparison of sedation techniques  

International Nuclear Information System (INIS)

Background. A change in practice at our institution resulted in increased use of anesthesia for CT scan of the chest in children who required sedation. Objective. To determine whether there is a difference in the frequency or severity of pulmonary atelectasis on CT scan in children sedated by anesthesiologists compared with children sedated by radiologists using intravenous pentobarbital. Materials and methods. Retrospective blinded review of 60 CT scans of the chest performed in 41 children. Forty-one studies in children sedated by radiologists (median age 29 months) were compared with 19 studies in children sedated by anesthesiologists (median age 25 months). Results. Atelectasis sufficient to obscure pulmonary metastases was shown in 5 of 41 (12 %) radiology sedations and 13 of 19 (68 %) anesthesiology sedations (P < 0.01). Higher grades of atelectasis were recorded in children under anesthesia (P < 0.01). ...

1999-07-01

246

Primary malignant lymphoma of the brain; Primaere maligne Lymphome des Gehirns  

Energy Technology Data Exchange (ETDEWEB)

Primary malignant lymphoma of the brain is a disease of unknown etiology, which is increasing in incidence and has an unfavorable prognosis. Despite the lack of specific changes on CT or MRI in most cases, these procedures may typically facilitate the diagnosis: A focal-enhancing mass with subependymal spread on CT or MRI and hyperattenuation on nonenhanced CT are the most reliable features in the diagnosis of primary malignant lymphoma of the brain. Peritumoral edema and mass effect are usually not prominent features. On unenhanced CT scans they usually appear homogeneously isodense to mildly hyperdense relative to the gray matter. On MRI these tumors are slightly hypointense on T1-weighted images and slightly hpyerintense on PD- and T2-weighted images relative to the gray matter. On CT and MRI enhancement is usually homogeneous. Contrast-enhanced MRI, with its multiplanar ...

1997-01-01

247

Liver trauma from penetrating injuries. Miscellanea, personal series, clinical and CT findings  

International Nuclear Information System (INIS)

Penetrating liver wounds are related to many causes and rank second after blunt abdominal and liver trauma. In this report are examined the clinical and radiological findings of personal series of patients with penetrating trauma, especially by firearms and stab and cut wounds. It will also tried to define the diagnostic workup of these traumas, which is especially based on CT signs of liver damage and associated changes and which is of basic importance for following treatment, both surgical or conservative. In the last seven years it was retrospectively reviewed 31 cases of penetrating liver trauma. The patients were 19 men and 12 women, ranging in age 18 to 73 (mean 42), with penetrating liver injuries from firearms (16 patients) and stab (9 cases) wounds; 6 patients had injuries from different cases. Abdominal CT was carried out in emergency with the CT Angiography (CTA) technique in all patients. In the patients with ...

2000-12-01

248

Visually Mediated Odor Tracking During Flight in Drosophila  

UK PubMed Central (United Kingdom)

Flying insects use visual cues to stabilize their heading in a wind stream. Many animals additionally track odors carried in the wind. As such, visual stabilization of upwind tracking directly aids...Full Text Available

249

Ultrasound diagnosis of cephalopagus conjoined twin pregnancy at 29 weeks  

UK PubMed Central (United Kingdom)

The authors report a case of a cephalopagus conjoined twin that was diagnosed at 29 weeks of gestation despite the mother having had two ultrasounds done previously. The fetus had one head and face,...Full Text Available

250

Timing of Births and Reproductive Success in Captive Red-tailed Phascogales, Phascogale calura  

Science.gov (United States)

... and sperm showed an association with the oviduct epithelial tissue. Estimate of sperm storage duration At ASDP in ... Sperm heads show no particular association with the epithelial tissue. enlarge fig...

251

The use of etoricoxib to treat an idiopathic stabbing headache: a case report  

UK PubMed Central (United Kingdom)

According to the International Headache Society, idiopathic stabbing headache (ISH), an indomethacin-responsive headache syndrome, is a paroxysmal disorder of short duration manifested as head pain...Full Text Available

252

The promises and perils of p53  

UK PubMed Central (United Kingdom)

Five studies show that disabling p53, an essential tumour-suppressor protein, improves the efficiency of stem-cell production. Are these results a ‘heads up’ that cancer cells...Full Text Available

2009-08-27

253

The Relationship Between the Stomatognathic System and Body Posture  

UK PubMed Central (United Kingdom)

In recent years, many researchers have investigated the various factors that can influence body posture: mood states, anxiety, head and neck positions, oral functions (respiration,...Full Text Available

2009-01-01

254

Swell opportunities for Japanese hydro  

Energy Technology Data Exchange (ETDEWEB)

Japan has upwards of 40 pumped storage plants in operation and new river sites are becoming scarce, but peak demand is still rising. A plant under construction in Okinawa offers a solution: make use of the head between the coastal cliffs and sea level, using seawater as the medium. (author)

1998-03-01

255

Superheavy elements - the quest in perspective  

International Nuclear Information System (INIS)

A review is presented of the quest for superheavy elements under the following headings - early history; physical and nuclear properties unique to superheavy elements; searches in nature; terrestrial samples; extra-terrestrial samples; and searches at accelerators. 72 references. (U.K.).

256

Structural aberrations in group A Staphylococcus bacteriophages.  

UK PubMed Central (United Kingdom)

Six related Staphylococcus phages spontaneously produced various abnormal head and tail structures: (i) giant capsids which were tailed and apparently contained nucleic acid; (ii) regular and irregular...Full Text Available

1976-05-01

257

Spindle cell carcinoma of head and neck: an immunohistochemical and molecular approach to its pathogenesis  

UK PubMed Central (United Kingdom)

BackgroundSpindle cell carcinoma (SpCC) is a rare microscopic type of cancer of the mouth and oropharynx. Although SpCC is thought to arise from squamous cell carcinoma (SCC), it...Full Text Available

2007-05-01

258

Single-molecular analysis of the binding state of myosin V and actin  

Energy Technology Data Exchange (ETDEWEB)

A class-V myosin, myosin V, one of 18 known classes of actin-based motor proteins, plays a role in transporting organelles within a cell. Unlike myosin-II, which functions as an assembly in the thick filaments of muscle, myosin V is a two-headed processive motor protein, which functions as a single molecule: myosin V performs many consecutive steps before it detaches from an actin filament accompanied by catalytic cycles of ATP (adenosine 5'-triphosphate) ase. The mechanism of such chemomechanical steps is explained by a 'Hand-over-hand model' in which two heads of myosin V alternately repeat single-headed and double-headed bindings with an actin filament. To investigate the binding state of myosin V at several key nucleotide states during ATP hydrolysis, we measured the mechanical properties of a single myosin V - actin complex by applying an external load with optical trap.

2006-03-21

259

Safety of pull-type and introducer percutaneous endoscopic gastrostomy tubes in oncology patients: a retrospective analysis  

UK PubMed Central (United Kingdom)

BackgroundPercutaneous endoscopic gastrostomy (PEG) allows long-term tube feeding. Safety of pull-type and introducer PEG placement in oncology patients with head/neck or oesophageal...Full Text Available

260

SPASE Resource Description - the VMO - NASA  

Science.gov (United States)

THEMIS-A: The Solid State Telescope (SST) measures the incoming intensity ... units (heads), each SST unit has two pairs of opposing ion and electron sensors. .... The five small satellites were launched together on a Delta II rocket and they ...

261

PET imaging of heat-inducible suicide gene expression in mice bearing head and neck squamous cell carcinoma xenografts  

UK PubMed Central (United Kingdom)

The ability to achieve tumor selective expression of therapeutic genes is an area that needs improvement for cancer gene therapy to be successful. One approach to address this is through the...Full Text Available

2009-02-01

262

ORNL nuclear waste programs annual progress report for period ending September 30, 1982  

Energy Technology Data Exchange (ETDEWEB)

Research progress is reported in 20 activities under the headings: spent fuels, defense waste management, commercial waste management, remedial action, and conventional reactors. Separate entries were prepared for each activity.

1983-05-01

263

Monitoring of the Water Levels in the Wetlands of Fourmile Branch Near the F- and H-Areas of SRS: FY97  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the piezometer network is to establish baseline hydraulic head data for the water table aquifer at the F- and H-Area seeplines prior to startup of the groundwater extraction/injection remediation system.

1999-06-02

264

In Their Own Words: Charlie Bolden  

National Aeronautics and Space Administration (NASA)

NASA Administrator Charles Bolden, who flew four space shuttle missions, talks about how space travel changed his life and how he applies his astronaut training to his work as the head of the space agency.

2011-10-19

265

Image-based modeling of tumor shrinkage in head and neck radiation therapy1  

UK PubMed Central (United Kingdom)

Purpose: Understanding the kinetics of tumor growth∕shrinkage represents a critical step in quantitative assessment of therapeutics and realization of adaptive radiation therapy....Full Text Available

2010-05-01

266

High-efficiency pump for space helium transfer. Final Technical Report  

Energy Technology Data Exchange (ETDEWEB)

A centrifugal pump was developed for the efficient and reliable transfer of liquid helium in space. The pump can be used to refill cryostats on orbiting satellites which use liquid helium for refrigeration at extremely low temperatures. The pump meets the head and flow requirements of on-orbit helium transfer: a flow rate of 800 L/hr at a head of 128 J/kg. The overall pump efficiency at the design point is 0.45. The design head and flow requirements are met with zero net positive suction head, which is the condition in an orbiting helium supply Dewar. The mass transfer efficiency calculated for a space transfer operation is 0.99. Steel ball bearings are used with gas fiber-reinforced teflon retainers to provide solid lubrication. These bearings have demonstrated the longest life in liquid helium endurance tests under simulated pumping conditions. Technology developed in the project also has application ...

1991-12-01

267

Head position modulates optokinetic nystagmus  

UK PubMed Central (United Kingdom)

Orientation and movement relies on both visual and vestibular information mapped in separate coordinate systems. Here, we examine how coordinate systems interact to guide eye movements of rabbits....Full Text Available

2011-08-01

268

Global Soil Water Holding Capacity Dataset from UNEP ... - GCMD - NASA  

Science.gov (United States)

Global Soil Water Holding Capacity Dataset from UNEP/GRID. Entry ID: GNV0025 ... Dao at unep.org. Contact Address: Head of Metadata & Socio-Economics Unit ...

269

Genome-Wide Analysis Reveals a Major Role in Cell Fate Maintenance and an Unexpected Role in Endoreduplication for the Drosophila FoxA Gene Fork Head  

UK PubMed Central (United Kingdom)

Transcription factors drive organogenesis, from the initiation of cell fate decisions to the maintenance and implementation of these decisions. The Drosophila embryonic salivary gland...Full Text Available

270

FFTF reactor assembly system technology  

Science.gov (United States)

An overview is presented of the FFTF reactor and plant together with descriptions of core components, core internals, core system, primary and secondary control rod system, reactor instrumentation, reactor vessel and closure head, and supporting test programs. (DG)

1975-11-13

271

FFTF reactor assembly system technology  

International Nuclear Information System (INIS)

An overview is presented of the FFTF reactor and plant together with descriptions of core components, core internals, core system, primary and secondary control rod system, reactor instrumentation, reactor vessel and closure head, and supporting test programs.

1976-03-13

272

Emotions run high in race for collider  

CERN Multimedia

The head of KEK expressed his dismay that SLAC has entered into a collaboration with 3 other US labs and proposes to build the next linear collider at Fermilab, Ilinois. KEK wants the next accelerator to be built somewhere in the Asian Pacific region (1 page).

2001-01-01

273

Diagnostic radiology: An Anglo-American textbook of imaging  

Energy Technology Data Exchange (ETDEWEB)

This multiauthored text is aimed particularly toward the resident or registrar training in diagnostic radiology. This is a text book on the entire scope of diagnostic imaging. It includes techniques and imaging modalities of all the systems, head, face and neck. The book covers the entire gamut of diagnostic radiology.

1986-01-01

274

Central gating of fly optomotor response  

UK PubMed Central (United Kingdom)

We study the integration of multisensory and central input at the level of an identified fly motoneuron, the ventral cervical nerve motoneuron (VCNM) cell, which controls head movements of the animal....Full Text Available

2010-11-16

275

Accelerated hyperfractionation (AHF) compared to conventional fractionation (CF) in the postoperative radiotherapy of locally advanced head and neck cancer: influence of proliferation  

UK PubMed Central (United Kingdom)

Based on the assumption that an accelerated proliferation process prevails in tumour cell residues after surgery, the possibility that treatment acceleration would offer a therapeutic advantage in postoperative...Full Text Available

2002-02-12

276

45 CFR Appendix to Part 1308 - Head Start Program Performance Standards on Services to Children With Disabilities  

Science.gov (United States)

...8Eligibility Criteria: Emotional/Behavioral Disorders Guidance for Paragraph...at-risk for emotional/behavioral disorders and their parents to help...Evaluation Team for Emotional/behavioral Disorders: Psychologist,...

2010-10-01

277

3 CFR - Guidelines for Human Stem Cell Research  

Science.gov (United States)

...false Guidelines for Human Stem Cell Research Presidential Documents ...2009 Guidelines for Human Stem Cell Research Memorandum for the Heads...scientifically worthy human stem cell research, including human...

2010-01-01

278

Influence of contrast-enhanced CT and MRI with or without SPIO particles on therapy and therapy costs for patients with focal liver disease; Einfluss von biphasischer Spiral-CT, nativer und eisenoxidverstaerkter MRT auf Therapie und Therapiekosten bei Patienten mit fokalen Leberlaesionen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Evaluation of the diagnostic efficacy and cost-benefit of contrast enhanced CT (CT) and MRI pre- and post-SPIO-particles in focal hepatic disease with consideration of therapeutic outcome. Results: In 34/52 (65.4%) of the cases the correct diagnosis was primarily stated by CT (sensitivity [se.] 85.2%, specificity [sp.] 44.0%). In additional 10/52 of the cases unenhanced MRI (se. 91.4%, sp. 75.0%) enabled correct diagnoses, and in another 6 cases the diagnosis was established only by SPIO-MRI (se. 100%, sp. 86.7%). Considering the possible therapeutic recommendation arising from each modality, CT would have induced needless therapy costs of 191,042 DM, unenhanced MRI of 171,035 DM, and SPIO-MRI of 7,311 DM. In comparison to the real therapy costs of 221,873 DM, this would have corresponded to an unnecessary increase of therapy costs of 86.1%, 77.1%, and 3.3%, respectively. In two cases (91 ...

2000-03-01

279

An extended CT scale technique for evaluating periprosthetic bone lesions - an in vitro study; Extended-field CT-Technik zur Evaluation von periprothetischen Knochenlaesionen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: In the present study the reduction of artifacts using an extended CT scale technique was examined in 5 vitallium and 5 titanium-aluminium-vanadium tumor prostheses. Methods: 5 titanium-aluminium-vanadium and 5 vitallium distal femur Mutars {sup trademark} tumor prostheses (Mutars {sup trademark} - Modular Universal Tumor And Revision System) were implanted in 10 human femur specimens. 110 artifical drill hole lesions of 1 mm, 2 mm, 3 mm, 5 mm and 8 mm diameter were placed in the bone around the hexagonal stem of the tumor prosthesis and furthermore in the proximal part of the femur. All specimens were examined using conventional CT and an extended CT scale technique in a slice thickness of 3 mm. Results: In the proximal part of the femur all drill holes could be detected using 3 mm slices, no artefacts were observed. Along the hexagonal stem smooth lines arising from each hexagonal plane could be observed. This ...

2001-12-01

280

September 2008 - Permanent Representative of Austria to the United Nations Office and specialised institutions in Geneva, Ambassador C. Strohal, visiting the ATLAS control with Collaboration physicist M. Aleksa, accompanied by CMS Collaboration physicist F. Pauss and Physics Deputy Department Head M. Doser.  

CERN Multimedia

September 2008 - Permanent Representative of Austria to the United Nations Office and specialised institutions in Geneva, Ambassador C. Strohal, visiting the ATLAS control with Collaboration physicist M. Aleksa, accompanied by CMS Collaboration physicist F. Pauss and Physics Deputy Department Head M. Doser.

2008-01-01

281

Osteocyte death and hip fracture.  

Science.gov (United States)

The viability of osteocytes can be demonstrated in sawn decalcified sections of bone by their lactate dehydrogenase activity. In the cancellous bone of the femoral head, the proportion of lacunae containing viable osteocytes decreased from 88 +/- 7% (mean +/- SD) at 10-29 years to 58 +/- 12% (P Ultimate compressive strength did not correlate with osteocyte viability. In the femoral head there is gradual, age-related reduction in osteocyte viability that can be more pronounced in hip fracture. Osteocyte death may affect bone quality by impairing repair of fatigue damage. PMID:8275364

1993-01-01

282

Organ doses and integral doses in X-ray diagnosis of the chest and of the head  

International Nuclear Information System (INIS)

Organ and tissue doses and integral doses in patients due to diagnostic x-ray examinations of the chest and of the head will be presented. These data have been obtained by measuring the dose distributions in man phantoms by LiF-dosimetry. The data will be compared with data obtained by Monte-Carlo calculations. To obtain average organ doses for a special type of examination for the population or for a specified subpopulation in the variation of the exposure, data due to the different techniques used by the different radiologists has to be known. Such data will be presented. The results of the investigation will be discussed in connection with the concept of the 'somatic significant.

1977-04-01

283

Manufacturing of golf club using wood-plastic combination produced by. gamma. -irradiation  

Energy Technology Data Exchange (ETDEWEB)

Wood-plastic combination (WPC) was produced by {gamma}-irradiation of persimmon impregnated with acrylonitrile and styrene. The hardness and strength of WPC obtained were higher than those of an unmodified wood. Thus, it was found that the WPC is suited for a head of golf club, because the Shore hardness value of WPC is 36% greater than that of unmodified wood. An impregnation method of monomers with some pigments could produce colored WPC without diminishing natural grain. Head of golf club could be manufactured from colored WPC in practice. (auhtor).

1992-01-01

284

Manufacturing of golf club using wood-plastic combination produced by #gamma#-irradiation  

International Nuclear Information System (INIS)

Wood-plastic combination (WPC) was produced by #gamma#-irradiation of persimmon impregnated with acrylonitrile and styrene. The hardness and strength of WPC obtained were higher than those of an unmodified wood. Thus, it was found that the WPC is suited for a head of golf club, because the Shore hardness value of WPC is 36% greater than that of unmodified wood. An impregnation method of monomers with some pigments could produce colored WPC without diminishing natural grain. Head of golf club could be manufactured from colored WPC in practice. (auhtor).

1992-01-01

285

Intermediate form of osteopetrosis with recessive inheritance  

International Nuclear Information System (INIS)

The clinical and radiographic features of the intermediate form of osteopetrosis in two sibs are presented in which the disorder appears to have been inherited as a recessive trait. Although this form of osteopetrosis has been poorly delineated, its recognition is practically important in order to give an accurate prognosis. This paper also presents an unusual complication of bilateral avascular necrosis of the femoral head in the younger sib. Radiographic changes of the femoral heads suggest those of Legg-Calve-Perthes disease, though the possibility of avascular necrosis following unrecognized femoral neck fracture is not completely excluded. (orig.).

286

Evaluation of perfusion of the femoral head after femoral neck fracture using bone scintigraphy  

International Nuclear Information System (INIS)

We treated 13 patients for femoral neck fracture. They consisted of 2 males and 11 females, and were classified according to Garden stage classification; Stage I, 3 cases; Stage II, 2 cases; Stage III, 2 cases; Stage IV, 4 cases. Two trochanteric fracture cases were used by control. We evaluated perfusion of the femoral head after femoral neck fracture using bone scintigraphy, which is considered useful for evaluation of perfusion of the femoral neck before operation. (author)

2002-09-01

287

Axiomatic Design Approach for a Reactor Head Structure Assembly  

Energy Technology Data Exchange (ETDEWEB)

Korea Atomic Energy Research Institute (KAERI) has been developing the integral reactor. The reactor head structure assembly (RHSA) is the structure installed over the reactor cover. Due to the characteristics of an integral reactor, there are many instrument cables and power cables coming out from the reactor cover and main components. The RHSA provides an interface location to connect these cables from Architecture Engineer (AE) and System Designer (SD). It also prevents a pipe whip and it prohibits instruments from becoming missiles. In this research, the axiomatic design approach for the RHSA is performed.

2006-07-01

288

A revised dosimetric model of the adult head and brain  

Energy Technology Data Exchange (ETDEWEB)

During the last decade, new radiopharmaceutical have been introduced for brain imaging. The marked differences of these tracers in tissue specificity within the brain and their increasing use for diagnostic studies support the need for a more anthropomorphic model of the human brain and head. Brain and head models developed in the past have been only simplistic representations of this anatomic region. For example, the brain within the phantom of MIRD Pamphlet No. 5 Revised is modeled simply as a single ellipsoid of tissue With no differentiation of its internal structures. To address this need, the MIRD Committee established a Task Group in 1992 to construct a more detailed brain model to include the cerebral cortex, the white matter, the cerebellum, the thalamus, the caudate nucleus, the lentiform nucleus, the cerebral spinal fluid, the lateral ventricles, and the third ventricle. This brain model has been included within a slightly modified ...

1996-06-01

289

A revised dosimetric model of the adult head and brain  

International Nuclear Information System (INIS)

During the last decade, new radiopharmaceutical have been introduced for brain imaging. The marked differences of these tracers in tissue specificity within the brain and their increasing use for diagnostic studies support the need for a more anthropomorphic model of the human brain and head. Brain and head models developed in the past have been only simplistic representations of this anatomic region. For example, the brain within the phantom of MIRD Pamphlet No. 5 Revised is modeled simply as a single ellipsoid of tissue With no differentiation of its internal structures. To address this need, the MIRD Committee established a Task Group in 1992 to construct a more detailed brain model to include the cerebral cortex, the white matter, the cerebellum, the thalamus, the caudate nucleus, the lentiform nucleus, the cerebral spinal fluid, the lateral ventricles, and the third ventricle. This brain model has been included within a slightly modified ...

1996-07-21

290

A model of episodic memory: mental time travel along encoded trajectories using grid cells.  

Science.gov (United States)

The definition of episodic memory includes the concept of mental time travel: the ability to re-experience a previously experienced trajectory through continuous dimensions of space and time, and to recall specific events or stimuli along this trajectory. Lesions of the hippocampus and entorhinal cortex impair human episodic memory function and impair rat performance in tasks that could be solved by retrieval of trajectories. Recent physiological data suggests a novel model for encoding and retrieval of trajectories, and for associating specific stimuli with specific positions along the trajectory. During encoding in the model, external input drives the activity of head direction cells. Entorhinal grid cells integrate the head direction input to update an internal representation of location, and drive hippocampal place cells. Trajectories are encoded by Hebbian modification of excitatory synaptic connections between hippocampal place cells and ...

2009-07-15

291

3D time-of-flight MR angiography of the intracranial vessels: optimization of the technique with water excitation, parallel acquisition, eight-channel phased-array head coil and low-dose contrast administration  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study is three folds: to compare the eight-channel phased-array and standard circularly polarized (CP) head coils in visualiazation of the intracranial vessels, to compare the three-dimentional (3D) time-of-flight (TOF) MR angiography (MRA) techniques, and to define the effects of parallel imaging in 3D TOF MRA. Fifteen healthy volunteers underwent 3D TOF MRA of the intracranial vessels using eight-channel phased-array and CP standard head coils. The following MRA techniques were obtained on each volunteer: (1) conventional 3D TOF MRA with magnetization transfer; (2) 3D TOF MRA with water excitation for background suppression; and (3) low-dose (0.5 ml) gadolinium-enhanced 3D TOF MRA with water excitation. Results are demonstrating that water excitation is a valuable background suppression technique, especially when applied with an eight-channel phased-array head coil. For central and proximal portions of the ...

2004-11-01

292

Whole-body tumor staging: MRI or FDG-PET/CT?; Ganzkoerpertumorstaging: MRT oder FDG-PET/CT  

Energy Technology Data Exchange (ETDEWEB)

Technical innovations such as the availability of movable patient platforms and the introduction of 32-channel systems have made whole-body MRI for tumor staging feasible. In addition, the development of dual-modality PET/CT systems offers the opportunity to perform anatometabolic tumor staging with whole-body coverage in a single session. Based on an increase in patient survival when applying a stage-adapted therapy in different malignant diseases the relevant question relates to the accuracies of whole-body MRI and whole-body PET/CT for TNM staging. This review article addresses whole-body tumor staging with MRI and FDG-PET/CT with special emphasis on diagnostic accuracies for staging different malignant diseases. (orig.) [German] Technische Neuerungen, wie die Verfuegbarkeit beweglicher Tischaufsaetze oder die Einfuehrung von 32-Kanal-Systemen, haben die Ganzkoerperbildgebung mit der MRT ermoeglicht. Die Entwicklung ...

2004-09-01

293

Studies on the mechanism of action of enterotoxin-induced fluid secretion in the gut  

International Nuclear Information System (INIS)

The mechanism of action of Clostridium difficile enterotoxin A (CA), of Escherichia coli enterotoxin (STa) and of cholera toxin (CT), which are known to cause severe diarrhea, were studied in a preparation of ligated jejunal loops of anesthetized rats in vivo. The toxins were administered intraluminally. Pharmacological agents, which were tested for their potency to influence toxin-related effects, were administered subcutaneously. Net fluid transport was determined gravimetrically, prostaglandin (PG) E_2-output into the lumen, cyclic adenosine monophosphate (cAMP) and cyclic guanosine monophosphate (cGMP) contents in the mucosa were measured by radioimmunoassay, serotonin-(5-HT)-output into the lumen was determined by high performance liquid chromatography. The histopathological effects of CA and CT were examined by light- and scanning electron microscopy. All three toxins caused net fluid secretion (FS). 5-HT_2-(ketanserin) and ...

1992-01-01

294

Feasibility of ultra-low-dose multislice CT colonography for the detection of colorectal lesions: preliminary experience  

Energy Technology Data Exchange (ETDEWEB)

Our objective was to evaluate the feasibility of ultra-low-dose scanning for multislice CT colonography in the detection of colorectal lesions. Twenty-seven patients (14 men, 13 women) with clinical indication for conventional colonoscopy were recruited. Multislice spiral CT (Somatom Plus 4 Volume Zoom, Siemens, Germany) examinations were performed after standard oral colonoscopic preparation and colonic distension with room air. Images were acquired using 2.5-mm collimation, 3.0-mm slice thickness, standard reconstruction kernel, 140 kVp, and 10 mAs. Supine and prone acquisitions were obtained in all patients. Images were analyzed on a workstation by two gastrointestinal radiologists. Conventional colonoscopy was performed on the same day in all patients and represented the standard of reference. Total radiation exposure was also calculated. All colorectal cancers were correctly identified at CT colonography (9 of 9, ...

2003-06-01

295

CT characterization of bile duct dilatation: Differential diagnosis of obstructive jaundice  

Energy Technology Data Exchange (ETDEWEB)

Each disease affecting the bile ducts tends to produce characteristic pattern of biliary dilatation: recurrent pyogenic cholangitis causes dilatation and straightening of the larger (central) intrahepatic ducts: clonorchiasis causes dilatation of the smaller (peripheral) intrahepatic ducts; and carcinoma along the extrahepatic ducts causes (proportional) dilatation and tortuosity of both larger and smaller intrahepatic ducts. To evaluate the specificity of the pattern and morphology of the dilated biliary tree on CT scans (CT characterization) three independent radiologists who were unifamiliar with the cases were asked to classify 62 CT scans in patients with obstructive jaundice. The case population consisted of 14 cases with recurrent pyogenic cholangitis, 18 cases with clonorchiasis and 30 cases with carcinoma along the extrahepatic ducts, which were intermixed randomly. Classification was made only on the basis of ...

1992-07-15

296

CT characterization of bile duct dilatation: Differential diagnosis of obstructive jaundice  

International Nuclear Information System (INIS)

Each disease affecting the bile ducts tends to produce characteristic pattern of biliary dilatation: recurrent pyogenic cholangitis causes dilatation and straightening of the larger (central) intrahepatic ducts: clonorchiasis causes dilatation of the smaller (peripheral) intrahepatic ducts; and carcinoma along the extrahepatic ducts causes (proportional) dilatation and tortuosity of both larger and smaller intrahepatic ducts. To evaluate the specificity of the pattern and morphology of the dilated biliary tree on CT scans (CT characterization) three independent radiologists who were unifamiliar with the cases were asked to classify 62 CT scans in patients with obstructive jaundice. The case population consisted of 14 cases with recurrent pyogenic cholangitis, 18 cases with clonorchiasis and 30 cases with carcinoma along the extrahepatic ducts, which were intermixed randomly. Classification was made only on the basis of ...

1992-07-01

297

Validity of the CT to attenuation coefficient map conversion methods  

International Nuclear Information System (INIS)

The most important commercialized methods of attenuation correction in SPECT are based on attenuation coefficient map from a transmission imaging method. The transmission imaging system can be the linear source of radioelement or a X-ray CT system. The image of transmission imaging system is not useful unless to replacement of the attenuation coefficient or CT number with the attenuation coefficient in SPECT energy. In this paper we essay to evaluate the validity and estimate the error of the most used method of this transformation. The final result shows that the methods which use a linear or multi-linear curve accept a error in their estimation. The value of mA is not important but the patient thickness is very important and it can introduce a error more than 10 percent in the final result.

2004-04-27

298

Trabecular scaffolds created using micro CT guided fused deposition modeling  

British Library Electronic Table of Contents (United Kingdom)

Free form fabrication and high resolution imaging techniques enable the creation of biomimetic tissue engineering scaffolds. A 3D CAD model of canine trabecular bone was produced via micro CT and exported to a fused deposition modeler, to produce polybutylene terephthalate (PBT) trabeculated scaffolds and four other scaffold groups of varying pore structures. The five scaffold groups were divided into subgroups (n=6) and compression tested at two load rates (49?N/s and 294?N/s). Two groups were soaked in a 25??C saline solution for 7?days before compression testing. Micro CT was used to compare porosity, connectivity density, and trabecular separation of each scaffold type to a canine trabecular bone sample. At 49?N/s the dry trabecular scaffolds had a compressive stiffness of 4.94?1.19?MP...

2008-01-01

299

The use of magnetic resonance imaging for diagnosis and staging of renal cell carcinoma  

International Nuclear Information System (INIS)

The use of magnetic resonance imaging for diagnosis and the preoperative staging of renal cell carconoma was evaluated in 79 patients with 88 tumors. Gradient-echo and spin-echo images before and after intravenous administration of Gadolinium DTPA were compared with the results of computed tomography (CT) and histologic staging. The two imaging techniques had comparable results: T-stage was predicted correctly with CT in 78%.4% and with MRI in 84.0% of the cases, while the N-stage was accurately assessed in 81.8% and 79.5%, respectively. MRI had some advantages in diagnosing perirental tumor spread and in excluding an infiltration beyond Gerota's fascia. Therefore, MRI is a true alternative to CT for staging large renal cell carcinomas and especially for patients with contraindications for iodinated contrast agents. (orig.).

300

Role of MRI in the diagnostic evaluation of parotid diseases  

International Nuclear Information System (INIS)

MRI findings in 13 patients with monolateral parotid tumor were compared with US, sialographic and CT findings. MRI did not allow an accurate diagnosis in 2 patients with diffuse chronic parotitis. MRI was superior to CT in 1 case in defining the intraglandular site of the lesion, and in 2 patients in showing the extraglandular involvement. MRI proved to be superior to CT thanks to its contrast resolution and to multiplanar imaging. MRI high contrast resolution made it possible to demonstrate neoplastic lesions of 4 mm in diameter. The lesion has low signal intensity on T1-weighted images and high signal intensity on T2-weighted. Parotid tumors cannot be characterized by signal intensity alone: only morphology allows to discriminate between benign and malignant lesions. To conclude, US is a screening method, while MRI is helpful in detecting multifocal lesions and in evaluating the tumor extent.

1988-01-01

301

PET/MRI hybrid imaging: devices and initial results  

British Library Electronic Table of Contents (United Kingdom)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...

2008-01-01

302

Dissection of the thoracic aorta - role of CT and MRT following aortic replacement  

International Nuclear Information System (INIS)

Dynamic CT and MRT were performed in 21 patients who had undergone prosthetic replacement of the aorta because of dissection of the thoracic aorta. There is no difference between MRI and dynamic CT in the demonstration of a persistent intimal flap, the formation of a thrombus and the assessment of the aortic diameter in patients who underwent surgery for thoraco-abdominal aortic dissection. MRI, however, is superior in the identification of the true and false lumen and the demonstration of the distal anastomotic site. The major advantages of MRI are that there is no need for intravenous contrast agents, that it is high sensitive to flow phenomena, and that it can demonstrate the aortic arch and the ascending aorta on sagittal oblique sections. The major disadvantages of MRI are the limited access to the patient during the procedure, and the inability to examine patients fitted with pacemakers or who are on assisted ventilation. Today, MRI is ...

303

Calcified metastases of the kidney. Etiology, pathogenesis, CT findings and diagnostic problems; Metastasi renali calcificate: eziologia, patogenesi, aspetti con tomografia computerizzata e diagnostica differenziale  

Energy Technology Data Exchange (ETDEWEB)

Aim of the work was to describe computerised tomography (CT) findings of calcified renal metastases focusing on differential diagnosis problems. Abdominal CT scans of 8000 patients with tumor, performed from 1984 to 1998, have been retrospectively reviewed. [Italian] Scopo del lavoro e' quello di descrivere gli aspetti con tomografia computerizzata delle metastasi renali calcificate enfatizzando le problematiche diagnostico differenziali. Sono state valutate retrospettivamente le indagini TC addominali di 8000 pazienti affetti da tumore nel periodo 1984-1998, analizzando le lesioni calcificate riscontrate.

2000-03-01

304

CT findings of malignant lymphoma of the anterior mediastinum. Differentiation from invasive thymoma  

Energy Technology Data Exchange (ETDEWEB)

CT findings were compared retrospectively between 9 cases with malignant lymphoma of the anterior mediastinum and 8 cases with invasive thymoma. CT findings of malignant lymphoma were as follows: (1) The majority of the tumors were bilateral and extended beyond the anterior mediastinum to the other mediastinum compartments. (2) Their margin was either smooth or lobulated. (3) Their density was either homogeneous or heterogeneous. In the case with heterogeneous density, ring, triangle and/or band-like low density areas, just like interspace of fused lymph nodes, were demonstrated. Calcification or cysts could not be shown. (4) Patent inherent vessels without deviation were occasionally demonstrated running through the tumors. (5) The tumors faced and contacted widely to anterior chest wall and often pressed the lung laterally at the anterior parietomediastinal pleural reflection. (6) Pleural implants were not demonstrated. (author).

1989-04-01

305

Brain CT image and handedness of schizophrenia  

International Nuclear Information System (INIS)

Brain CT images were reviewed of 98 schizophrenic patients and 90 healthy persons in relation to handedness and aging. CT images were further reconstructed to examine morphologically subtle changes in each region. Schizophrenic patients had progressive brain atrophy and dilated lateral ventricles, especially on the left side and in the posterior part of the lateral ventricle. These findings were more marked in left-handed than in right-handed schizophrenic patients. According to age groups, there were significant differences between schizophrenic and normal persons over the age of 40. The incidence of left handedness was significantly higher in schizophrenic patients in their fourties than the age-matched normal persons (31.4% vs 15.1%). Morphological abnormality and laterality might be due to the same pathologic consequences. (N.K.).

306

Biomechanical properties of the femoral neck relative to osteosynthesis methods and bone mineral content assessed by computed tomography  

International Nuclear Information System (INIS)

Bone mineral content as determined by computerized tomography (CT) and mechanical strength on axial loading were compared in 36 cadaveric femur specimens. Based on the CT measurements of density and area, the mass of a transverse slice of the femur was estimated. Highly significant correlations were demonstrated between strength and cancellous bone density. Even higher correlations were revealed when the bone masses of the proximal and distal femoral areas were calculated. Based on these findings, an equal distribution of the effective mass of the femur was postulated. This hypothesis was confirmed in an experimental rotational model. The CT attenuation values were also correlated to direct measurements of bone mineral content, i.e. calcium. Moreover, the strength of different metal implants, commonly used in femoral neck fractures, were assessed in cadaver specimens. 134 refs., 13 figs., 12 tabs.

307

Benign lymphoepithelial lesion of the parotid gland in AIDS patients: CT characteristics  

International Nuclear Information System (INIS)

Contrast agent-enhanced CT scans in nine male patients with histologically proved benign lymphoepithelial lesions of the perotid gland were reviewed. All scans showed cystic-appearing masses with peripheral rim enhancement corresponding to the macroscopic appearance of the lesion. Five patients were seropositive for human immunodeficiency virus (HIV) infection or had infections seen in acquired immunodeficiency syndrome. Three patients were members of high-risk groups. Only one patient had symptoms of the SICCA syndrome. Once a rare cause of parotid gland enlargement, benign lymphoepithelial lesions have recently been seen with increasing frequency in patients with HIV infection. Although the CT appearance is not pathognomic, correlation results of aspiration cytology and with clinical history can lead to a preoperative diagnosis of a benign lymphoepithelial lesion.

308

Adenopathies in lung cancer: a comparison of pathology, Computed Tomography and endoscopic ultrasound findings  

International Nuclear Information System (INIS)

A prospective comparative study with pathology was performed to assess the clinical value of Computed Tomography (CT) and endoscopic ultrasound (EUS) for nodal staging in lung cancer. A total of 329 nodal stations were dissected or sampled and 755 lymph nodes were examined at histology. On a pre-station basis, CT had greater sensitivity (74%) than EUS (56%), but EUS was more specific (83% versus 93%). The accuracy rates of the two techniques were similar. In conclusion, endoscopic ultrasound should be part of a routine preoperative diagnostic approach to non-small-cell lung cancer., because of its high specificity. Results can be improved when EUS and CT are combined., which suggests that these imaging modalities should be used together in selected patients for the noninvasive staging of non-small-cell lung cancer to identify local lymphatic spread.

1999-01-01

309

3-D brain CT image display for planning of craniofacial operation  

International Nuclear Information System (INIS)

The authors have been developing a 3D brain CT image display system for planning of craniofacial operations. This system helps doctors plan craniofacial operations on a graphic display (GD) terminal by rendering 3D images reconstructed from a set of slices. The authors reveal how the system generates 3D shapes of organs from given CT images and how it modifies or transforms the obtained shapes according to the user's request. The system functions now available are extraction and display of the skull and the skin, measurement of the distance between two points on the skull given through the GD terminal, and generating and eliminating a polygonal region arbitrarily given on the skull as an operative region. (Auth.).

310

Analytical study on integrity of BWR reactor internal structures against water hammer under RIA conditions  

Energy Technology Data Exchange (ETDEWEB)

The integrity of the RPV head and reactor internals was assessed by means of fluid-structural analyses using a coupled method to evaluate the water hammer phenomenon arising from high burnup fuel failure under RIA conditions. The fluid viscosity effect on the water column burst as well as the complex three-dimensional flow paths caused by a core shroud and standpipes were considered in this study. The three analysis scenarios were designed to investigate the above mentioned influential factors separately. In the first scenario, a two-dimensional axisymmetric reactor vessel model without any reactor internals was modeled to assess the influence of the fluid dynamics in the NSC RIA regulatory evaluation. This model has an actual RPV geometry and can be simply separated from other influential factors in order to concentrate only on investigation of the fluid viscosity effect. In the second scenario, a two-dimensional axisymmetric reactor vessel model with major ...

2003-07-01

311

The role of computed tomography in complex facial trauma  

Energy Technology Data Exchange (ETDEWEB)

Tridimensional localization of bone and soft tissue injuries in complex facial trauma is fundamental for treatment. The face can be conceptualized as 3 groups of interconnected osseous struts that are oriented in the horizontal, sagittal and coronal planes. Each group of struts is closely related to specific soft tissue structures that are susceptible to injury. Any single CT section in the coronal plane or in the axial plane contains parts of one or more these struts. Facial CT in biplane were performed in 32 patients of facial trauma. The most common site of facial fractures is found in middle part of horizontal struts, geometrically in anteromedial portion of the inferior orbital fissure of the face. The most common soft tissue injury combined with facial fracture is hematoma and/or herniated orbital contents into the maxillary sinus. The serious combined soft tissue injuries were ocular rupture, retroorbital hematoma and optic nerve injury ...

1988-02-15

312

The Prevalence of Concha Bullosa and Nasal Septal Deviation and Their Relationship to Maxillary Sinusitis by Volumetric Tomography  

UK PubMed Central (United Kingdom)

The objective of this study was to determine the prevalence of concha bullosa and nasal septal deviation and their potential relationships to maxillary sinusitis. 883 CT scans taken at Creighton University...Full Text Available

2010-01-01

313

TECAB - Totally Endoscopic Coronary Artery Bypass  

Medline Plus

... CT angiograph for the peripheral rteries. a beautiful 3D-vision on the structures inside e chest. Okay. ... have an angled camera here. This is a 3D camera, and the surgeon has got th What ...

314

Regulation of the brown and white fat gene programs through a PRDM16/CtBP transcriptional complex  

UK PubMed Central (United Kingdom)

Brown fat is a specialized tissue that can dissipate energy and counteract obesity through a pattern of gene expression that greatly increases mitochondrial content and uncoupled respiration. PRDM16...Full Text Available

2008-05-15

315

Quantifying the accuracy of automated structure segmentation in 4D CT images using a deformable image registration algorithm  

UK PubMed Central (United Kingdom)

Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. One key component of 4D radiotherapy planning...Full Text Available

2008-04-01

316

ORNL RSIC-18 - NASA Technical Report Server (NTRS)  

Science.gov (United States)

W. Wayne Scott. ABSTRClCT. Primary proton and secondary particle doses (both .... W. Wayne Scott and R. G. Alsmiller, Jr., Comparisons of Results Ob- ...

317

Noise suppression in scatter correction for cone-beam CT  

UK PubMed Central (United Kingdom)

Scatter correction is crucial to the quality of reconstructed images in x-ray cone-beam computed tomography (CBCT). Most of existing scatter correction methods assume smooth scatter distributions. The...Full Text Available

2009-03-01

318

MRI in pleural diseases  

International Nuclear Information System (INIS)

The MRI and CT appearances in 48 patients with histologically confirmed benign and malignant pleural abnormalities were compared retrospectively. Abnormal pleural changes were shown in 47 out of the 48 patients by high signal intensity of the pleura in T_2-weighted sequences and in contrast enhanced T_1-weighted sequences on MRI. CT showed abnormalities in 45 out of 48 patients. Delineation of pleural and pulmonary changes by CT was possible in 13 out of 23 cases, and pleural disease from effusions in 15 out of 28 cases. T_2-weighted MRI was successful in 14 out of 23 and 4 out of 28 cases, respectively. T_1-weighted images after contrast were successful in 20 out of 23 and 22 out of 28 cases, respectively. Indications of malignant pleural disease were the presence of mediastinal or circumferential involvement or involvement of the entire pleura, thickness of more than 10 mm and nodular changes. The most reliable sign of ...

320

Is hepatotropic contrast enhanced MR a more effective method in differential diagnosis of hemangioma than multi-phase CT and unenhanced MR?  

UK PubMed Central (United Kingdom)

BackgroundCavernous hemangiomas are the most frequent neoplasms of the liver and in routine clinical practice they often need to be differentiated from malignant tumors and other...Full Text Available

321

Is Computerized Tomography Angiographic Surveillance Valuable for Prevention of Tracheoinnominate Artery Fistula, a Life-Threatening Complication after Tracheostomy?  

UK PubMed Central (United Kingdom)

ObjectiveThe aim of this study was to evaluate the utility of volume-rendered helical computerized tomography (CT) angiography focusing tracheostomy tube and innominate artery for...Full Text Available

2011-02-01

322

High resolution computed tomography in the study of cervical spine trauma  

International Nuclear Information System (INIS)

Correct ortopedic therapy for traumas of the cervical rachis requires perfect knowledge of the spatial balance of the fracture focus. The authors belive Computed Tomography (CT) to be the most suitable, and often indispensable, method for this purpose. Twenty-four patients were examined for traumatic pathology of the cervical rachis. In 7 cases with clinically minor traumas, the negative outcome of the traditional traumas, the negative outcome of the traditional exam was considered reliable and sufficient for therapeutic purposes. The extant 17 patients were examined also by means of CT, either to better dermine the characteristics of skeletal lesions already ascertained with traditional techniques or to asses the presence of clinically-suspected osteo-articular lesions, even with negative conventional X-rays. For 9 of these patients orthopedic treatment was considered sufficient, whereas 8 patients underwent surgery and were subsequently ...

1989-01-01

323

Focal lesions in external auditory canal: computed tomography images  

International Nuclear Information System (INIS)

To analyze and review the most common focal lesions of the external auditory canal (EAC), describing the computed tomography (CT) findings. The CT images of EAC were reviewed in a series of 167 patients. Abnormal findings were recorded in 13 cases. The CT images were correlated with otoscopic and/or intraoperative findings. There were four cases of osteoma (one located outside the EAC); all of which were treated surgically, as was the one case of exostosis. Six patients presented debris in EAC, coinciding with clinical evidence of external otitis. There were two cholesteatomas derived from EAC, one of them secondary to survery to treat osteoma. On patient was diagnosed as having a basal cell carcinoma of the ear, extending to EAC, but refused to undergo surgery. Five patients presented small triangular laminae of dense bone arising from the upper wall of the EAC which were defined as abnormal variants of the fusion of the ...

324

Early detection of bone metastases of Ewing's sarcoma by magnetic resonance imaging  

International Nuclear Information System (INIS)

Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).

325

Diagnostic possibilities following implantation of carbon-fibre-reinforced plastic (CFRP) total hip arthroplasty  

International Nuclear Information System (INIS)

Introduction: There are many problems in the radiological diagnosis of aseptic loosening in total hip arthroplasty. Computed tomography (CT) and magnetic resonance tomography (MRT) are not usable for metallic implants (stainless steel, cobalt alloy, titanium alloy). Material and Methods: From April 1993 to December 1993 15 CFRP non-cemented hip prostheses have been implanted. In a prospective clinical study plane radiographs, CT and MRT have been analysed. Results: Three stems were revised (1 femoral fracture, 1 severe thigh pain, 1 aseptic loosening). CFRP are not visible in plane radiographs. There was a complete (two-third of the cases) or nearly complete (one-third of the cases) small sclerotic interface between the prosthesis and the bone, these were apparent in CT and MRT in stable implant cases and did not have any clinical correlations. Discussion: The small sclerotic interface is quite different in comparison to so ...

326

Diagnosis of Ewing's sarcoma in the thoracic spine - problems in differential diagnosis  

International Nuclear Information System (INIS)

Spinal Ewing's sarcomas are rare and cause problems in differential diagnosis. The radiologic, nuclear medicine and CT findings in two children with histologically proven Ewing's sarcoma are presented and problems in differential diagnosis discussed. Biopsy should be done early. (orig.).

327

Ct3d: tracking microglia motility in 3D using a novel cosegmentation approach  

UK PubMed Central (United Kingdom)

Motivation: Cell tracking is an important method to quantitatively analyze time-lapse microscopy data. While numerous methods and tools exist for tracking cells in 2D time-lapse images,...Full Text Available

2011-02-15

328

Computed tomography of the mediastinal tumor  

Energy Technology Data Exchange (ETDEWEB)

Forty-one cases of mediastinal tumor examined by computed tomography were reviewed. CT findings of the mediastinal malignancy were as follows: 1) inhomogeneous density on contrast CT, 2) equivocaton of fat plane surrounding the tumor, 3) irregular margin. Benign teratoma had smooth margin and included fat or calcification density. Mediastinal seminoma was observed as a lobulated mass with no calcification on CT. These findings were similar to the patterns of malignant thymoma or lymphoma. Consequently, it was very difficult to differentiate between malignant thymoma and malignant lymphoma by CT. According to our data, malignant thymoma tended to expand to only one side of the anterior mediastinum and to invade the anterior chest wall. On the other hand, malignant lymphoma of anterior medistinal type expanded into the trachea and the superior vena cava. In patients with sarcoidosis, the enlargement of ...

1984-12-01

329

Computed tomography and magnetic resonance imaging of acquired abnormalities of the inner ear and cerebello-pontine angle  

International Nuclear Information System (INIS)

CT and MRI of acquired abnormalities of the inner ear and cerebello-pontine angle present themselves with very typical findings. The imaging should be adapted to the pathology looked for and either CT or MRI should be used alone or in combination.CT, especially high resolution CT (HRCT), provides an excellent bone contrast, while MRI has a much superior soft tissue contrast. Acute inflammatory changes of the inner ear are solely depicted by contrast-enhanced MRI. HRCT excellently depicts osseous changes of the inner ear and cerebellopontine angle such as chronic ossifying labyrinthitis occurring after acute labyrinthitis, otosclerotic or traumatic changes. Tumorous changes not yielding to bony changes are best delineated by MRI. Posttraumatic hemorrhage and chronic fibrotic changes within the labyrinth are depicted by MRI, only. In conclusion HRCT and MRI are excellent methods to delineate acquired ...

2003-03-01

330

Closed loop obstructions of the small bowel: role of Computed Tomography  

International Nuclear Information System (INIS)

Small bowel obstructions can be distinguished into more simple and closed loop obstructions. The latter is a more severe condition which is often complicated by strangulation with vascular impairment, edema and intramural and mesenteric hemorrhage. Consequent arterial insufficiency rapidly leads to ischemia, infarction and necrosis. The radiologist plays a role in the early recognition of the closed loop obstruction and of any sign of strangulation. The role of CT in the diagnosis and workup of patients with suspected intestinal occlusion has been analyzed in the literature with reported 63% sensitivity, 78% specificity and 66% accuracy. CT is also capable of revealing the causes of occlusion in 73-95% of cases. The above CT signs allow to identify closed loop obstruction and also small bowel strangulation, thus supplying a valuable contribution to diagnosis and accurate preoperative evaluation. The conclusion is that ...

1999-01-01

331

Body weight-tailored contrast material injection protocol for 64-detector row computed tomography coronary angiography  

International Nuclear Information System (INIS)

The aim of this study was to assess the body weight-tailored contrast material injection protocol for 64-detector computed tomography (CT) to maintain optimal coronary CT attenuation. A total of 60 patients who underwent CT coronary angiography were assigned to one of three groups: protocol A, total of 0.7 ml kg"-"1 with 300 mg I/ml iodine concentration; protocol B, total of 0.6 ml kg"-"1 with 350 mg I/ml; protocol C, total of 0.7 ml kg"-"1 with 350 mg I/ml. The injection duration was 10 s in all patients. The proportion of intracoronary attenuation values >325 Hounsfield unit (HU) was compared on a per-vessel and per-patient basis. The attenuation value was significantly more likely to exceed 325 HU with protocol C (95% for reader 1 and 90% for reader 2) than with protocol A or B on the per-vessel analysis (P325 HU) with 64-detector CT when using an injection duration of 10 s. (author)

2011-01-01

332

Body dose conversion factors for computerized tomography  

International Nuclear Information System (INIS)

While there have been many experimental and calculational investigations on absorbed dose distribution in the patient resulting from conventional X-ray procedures, such data for computerized tomography (CT) are still sparse. As this diagnostic procedure has shown a rapid increase in application during recent years, we have determined absorbed dose to body organs in a human phantom resulting from CT examinations. The exposure model consists of the heterogeneous MIRD-5 phantom and a suitable Monte-Carlo method to calculate absorbed dose to organs of interest. The exposure conditions are specified according to the exposure specifications of a CT-scanner currently in use. The calculations cover the range of body tissues of interest in terms of organ absorbed doses as well as a risk weighted absorbed dose. A detailed example showing the calculation of red bone marrow dose is given and a somatic effective dose equivalent Hsub(ES) ...

1980-10-31

333

Assessment of the value of various tomography modalities for diagnostic evaluation of the female genital system  

International Nuclear Information System (INIS)

The comprehensive survey explains the indications and the specific value of the modern tomographic modalities with respect to the various diagnostic issues. Numerous reproductions of CT, MRI, US scans illustrate the aspects discussed. (orig./CB)

2001-09-01

334

A study on brain CT of neurological endemic cretinism  

International Nuclear Information System (INIS)

A study on brain CT was made in 20 cases of typical endemic cretinism and 15 cases of normal persons. These patients from severely iodine deficient area were diagnosed as neurological endemic cretinism characterized by severe mental retardation with impairment of hearing, speech, neuromotor, etc. to varying degrees. The brain CT showed that there were many and deep depressions in cerebral cortex, especially in frontal and parietal lobes of some cretins, the lateral ventricle system was dilated, particularly in posterior part of it, and the interhemisphere fissure, lateral fissure and subarachnoid cisterns were also expanded. The CT value of cortex was higher and white matter was lower than that of normal persons. In some severe cases, the two hemispheres of brain were not the same in size. These findings above indicated that these endemic cretins had a severe retardation of brain development including cerebral cortex and ...

335

A computer-assisted method for 3D subtraction angiography based on spiral CT  

International Nuclear Information System (INIS)

The objective of this study was to develop a method for 3D subtraction CT angiography and to optimize the visualization after semiautomatic segmentation. Ten patients with aneurysms of the abdominal aorta were examined using spiral CT. To reconstruct the vessels, as well as adjacent organs such as the liver and kidneys, one image data volume was acquired before and after injection of the contrast agent. The CT scans were obtained with a Siemens Somatom Plus 4. To improve the results of automatic segmentation, as well as visualization by maximum intensity projection (i.e. removal of bony structures), subtraction of both image volumes is necessary. However, small translation shifts disturb the subtraction process and produce artificial contours. To calculate the disparities along the three coordinate axes of two corresponding image volumes, a cepstrum filter is applied to a pair of image volumes. After detection of the ...

336

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT  

UK PubMed Central (United Kingdom)

Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available

2010-01-01

337

Spectrum of abdominal pathologies detected with CT in long term dialysis patients  

Energy Technology Data Exchange (ETDEWEB)

As a consequence of the expanded use of long term hemodialysis and continuous ambulatory peritoneal dialysis (CAPD) treatments and extended life spans, complications of end-stage renal disease and dialysis treatments are being encountered with increasing frequency in these patients. Computed tomography can accurately depict many of the potential complications of end-stage renal disease on dialysis. This article presents the abdominal CT findings of 429 end-stage renal disease patients who are on either hemodialysis or continuous ambulatory peritoneal dialysis treatment.

2009-11-15

338

Sonography and Computed Tomography in the evaluation of giant Baker's cysts  

International Nuclear Information System (INIS)

The US study of the posterior compartment of the knee usually allows the clinical suspicion of popliteal cyst to be confirmed. Neverthless, in case of giant Baker's cysts - which are, at any rate, less frequent -US diagnosis is more difficult. CT can help determine the benign nature of the lesion, and hallow an accurate spatial evaluation. Moreover CT, when accurately performed, demonstrates the caudal or cranial cystic spread, together with its clear separation from adjacent muscular tissues. Direct coronal scans are more useful to obtain better spatial definition than reformatted images.

1991-01-01

339

Role of Spiral and Multislice Computed Tomography in the evaluation of traumatic and spontaneous oesophageal perforation. Our experience  

International Nuclear Information System (INIS)

Purpose: To assess the role of CT in the evaluation of traumatic and spontaneous oesophageal perforation. Materials and methods: From March 2001 to May 2003, we studied 12 patients (7 males and 5 females; age range: 25-66 years, mean age: 43.5 years) with suspected oesophageal perforation due to motor-vehicle accidents (4 cases), stab wound (one case), post-intubation (2 cases), foreign body ingestion (2 cases) and spontaneous (3 cases). Five patients underwent standard chest and cervical radiography; two patients with suspected foreign body ingestion also underwent a gastrografin swallow study; all of the 12 patients underwent CT of the neck, chest and abdomen before and after intravenous, and in four cases oral, administration of contrast material. Results: In 5 patients with cervical, thoracic and abdominal trauma, the CT examination showed the presence of pleuroparenchymal injury (pneumothorax, pleural effusion and ...

2005-03-01

340

Pulmonary emphysema quantitation with Computed Tomography. Comparison between the visual score with high resolution CT, expiratory density mask with spiral CT and lung function studies; Valutazione quantitativa dell`enfisema polmonare mediante Tomografia Computerizzata. Confronto tra il punteggio visivo con alta risoluzione nell`inspirazione, maschera della densita` automatica con Tomografia Computerizzata spirale nell`espirazione ed esami funzionali respiratori  

Energy Technology Data Exchange (ETDEWEB)

CT is the most accurate method to detect pulmonary emphysema in vivo. They compared prospectively two different methods for emphysema quantitation in 5 normal volunteers and 20 consecutive patients with chronic obstructive pulmonary disease (COPD). All subjects were submitted to function tests and HRCT; three scans were acquired at preselected levels during inspiration. The type and extent of pulmonary emphysema were defined by two independent observers under blind conditions. Disagreements were subsequently settled by consent. All subjects were also examined with expiratory spiral CT using a density mask program, at two different cut-off levels (-850,-900 HU). Visual score and expiratory spiral density mask values (-850 HU) were significantly correlated (r = 0.86), but the visual extent of emphysema was always higher than shown by expiratory spiral CT. The emphysema extent assessed with both CT methods ...

1997-04-01

341

Pulmonary emphysema quantitation with Computed Tomography. Comparison between the visual score with high resolution CT, expiratory density mask with spiral CT and lung function studies  

International Nuclear Information System (INIS)

CT is the most accurate method to detect pulmonary emphysema in vivo. They compared prospectively two different methods for emphysema quantitation in 5 normal volunteers and 20 consecutive patients with chronic obstructive pulmonary disease (COPD). All subjects were submitted to function tests and HRCT; three scans were acquired at preselected levels during inspiration. The type and extent of pulmonary emphysema were defined by two independent observers under blind conditions. Disagreements were subsequently settled by consent. All subjects were also examined with expiratory spiral CT using a density mask program, at two different cut-off levels (-850,-900 HU). Visual score and expiratory spiral density mask values (-850 HU) were significantly correlated (r = 0.86), but the visual extent of emphysema was always higher than shown by expiratory spiral CT. The emphysema extent assessed with both CT methods ...

1997-01-01

342

Computerized tomography in the diagnosis and follow up in three observations of primitive suprasellar germinoma  

International Nuclear Information System (INIS)

Three cases of primitive suprasellar germinomas are reported: the tumors show typical clinical signs (diabetes insipidus, disfunctions), but CT findings are not so specific. It is very important to reach a correct diagnosis based on clinical and radiological findings, because of very high radiosensibility of the tumor. The accuracy of preoparative diagnosis has been enhanced by CT in addition to conventional neuroradiological examinations. Due to the possible risk of meningeal spreading following biopsy, some authors prefer to avoid biopsy and to treat directly the patient by radiotherapy; a rapid reduction of the tumor size at the dose of 30 Gy suggest a possible germinoma.

1986-01-01

343

Computed tomography of hilar cholangiocarcinoma: a new sign  

International Nuclear Information System (INIS)

Thirty-seven patients with histologic proof of cholangiocarcinoma at the confluence were examined by computed tomography (CT) to determine whether this examination is of value in the assessment of these patients for surgery and whether there are any features specific to this type of tumor. Thirty-two patients showed intrahepatic duct dilatation; six of these showed dilatation of ducts in one lobe only. Eighteen patients had intrahepatic low-attenuation areas, while eight had a mass lesion in the porta hepatis. The results of this study show that CT provides useful anatomic information preoperatively but that the appearances are nonspecific. Lobar atrophy is highly suggestive of hilar cholangiocarcinoma, either of long-standing or with unilateral portal venous involvement.

1986-04-14

344

Computed tomography in the evaluation of 41 cases of Ewing's sarcoma  

International Nuclear Information System (INIS)

Computed tomography (CT) has already proved extremely effective both in cerebral and abdominal pathology. Several recent publications describing first heterogeneous series [1, 2, 7, 11-17], then studies of a single type of lesion [3-6, 8] have illustrated its usefulness in the study of bone lesions. This report deals with 41 cases of Ewing's sarcoma studied by CT at the Institut Gustave Roussy from October 1977 to July 1981, and tries to show both the limitations and indications of this technique for the diagnosis, treatment, and follow-up of Ewing's sarcoma as well as in the diagnosis of any eventual recurrence. (orig.).

345

Childhood neuroborreliosis: clinicoradiological correlation  

Energy Technology Data Exchange (ETDEWEB)

We report the cranial CT and MRI findings in three children with Lyme disease (neuroborreliosis). The neuroimaging findings in children have been rarely reported. We found cranial MRI far superior to cranial CT. Ring-enhancing lesions have been described in acute disseminating encephalomyelitis and multiple sclerosis but not in neuroborreliosis. Although other infectious and inflammatory diseases cannot be excluded, Lyme disease should be included in the differential diagnosis and put forward as being the most likely diagnosis in the appropriate clinical setting. Gadopentetate dimeglumine is helpful in assessing the response to antibiotic treatment. (orig.)

1995-10-01

346

CT colonography and cost-effectiveness  

Energy Technology Data Exchange (ETDEWEB)

CT colonography (CTC) is increasingly advocated as an effective initial screening tool for colorectal cancer. Nowadays, policy-makers are increasingly interested in cost-effectiveness issues. A number of studies assessing the cost-effectiveness of CTC have been published to date. The majority of findings indicate that CTC is probably not cost-effective when colonoscopy is available, but this conclusion is sensitive to a number of key parameters. This review discusses the findings of these studies, and considers those factors which most influence final conclusions, notably intervention costs, compliance rates, effectiveness of colonoscopy, and the assumed prevalence and natural history of diminutive advanced polyps. (orig.)

2008-11-15

347

Longitudinal changes in extended roles in radiography  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The purpose of this research was to identify the extent and scope of changes to radiography practice. Method: Questionnaires were sent to radiology managers at acute National Health Service (NHS) hospitals in 2000 as a follow-up to an initial survey conducted in 1998. Information was sought on region, teaching/non-teaching status, the nature of extended role tasks undertaken and the year in which these tasks were first undertaken. Results: Some 172 questionnaires were returned from a total of 253 dispatched (68%). In 161 hospitals radiographers administered intravenous injections and performed barium enemas in 119 hospitals, while a red-dot system was in operation in 141 hospitals. Reporting by radiographers had increased since 1998. Replies indicated that, at 124 hospitals, radiographers were reporting in ultrasound. Skeletal reporting was the second most-frequently-reported activity, with 63 hospitals indicating that radiographers reported in this modality, while barium ...

2002-11-01

348

Case report: Denys- Drash syndrome.  

Science.gov (United States)

BACKGROUND: Denys-Drash Syndrome (DDS) is an uncommon disorder that appears sporadically and in rare cases may be inherited as an autosomal dominant trait It manifests either at birth or within the first year of life and typically consists of the triad of congenital nephropathy, Wilms tumour and intersex disorder. CASE REPORT: A 10 year-old Caucasian girl was referred to the Dental Department, at Glasgow Royal Hospital for Sick Children by her Paediatric Nephrologist Consultant. The patient was being teased by her peers over her markedly discoloured teeth. The dental history revealed that the patient was a regular dental attendee from an early age. She was dentally anxious having only experienced dental treatment under general anaesthesia (GA) when she was 4 years old. Apparently her primary dentition also showed a generalised discolouration. TREATMENT: This consisted of multiple visits for diet analysis and tooth brushing instruction with the use of disclosing ...

2007-12-01

349

Role of early phase helical CT images in the evaluation of wall invasion of colorectal cancer. Pathological correlation  

Energy Technology Data Exchange (ETDEWEB)

The usefulness of helical CT early phase images optimized by the SmartPrep method for evaluation of wall invasion by colorectal cancer was investigated. Between August 1997 and September 1998, CT was performed to evaluate the primary tumor and local extension in 10 consecutive patients with colorectal cancer confirmed by barium enema- and/or colonoscopy. Early-phase images were acquired by using SmartPrep application software. This method allows the optimal scan delay time to be obtained by continuous monitoring of increases in CT values after injection of contrast medium. Sections of the surgical specimens, close to the same plane as the CT images, and of the same slice thickness, were analyzed histopathologically. All 10 cancers, regardless of size, showed strong enhancement on the early-phase images (81.4-112 HU, mean: 95.1 HU). The strongly enhanced image areas on CT ...

2000-02-01

350

Le leucodistrofie: aspetti clinici e quadri con Tomografia Computerizzata e con Risonanza Magnetica  

International Nuclear Information System (INIS)

Leukodystrophies are inherited white matter diseases due to abnormalities occurring in myelin synthesis and/or maintenance. The most common types of these rare childhood conditions are represented by adrenoleukodystrophy, metachromatic leukodystrophy, Canavan's, Alexander's, Krabbe's, and Pelizaeus-Merzbacher's diseases. Most of them are lethal during childhood, with the exception of the adrenoleukodystrophy-adrenomyeloneuropathy complex, which sometimes, during its early phases, may be cured with a dietary therapy. The aims of this paper are: 1) the description of inheritance factors, pathogenesis, pathological and clinical findings of each of the most frequent childhood leukodystrophies; 2) the description of the most common patterns of these conditions on CT and MR imaging; 3) the evaluation of the diagnostic capabilities of these two imaging techniques and the comparison of their results. Finally, some of the therapies suggested for the mild forms of these ...

1991-01-01

351

Influence of contrast-enhanced CT and MRI with or without SPIO particles on therapy and therapy costs for patients with focal liver disease  

International Nuclear Information System (INIS)

Purpose: Evaluation of the diagnostic efficacy and cost-benefit of contrast enhanced CT (CT) and MRI pre- and post-SPIO-particles in focal hepatic disease with consideration of therapeutic outcome. Results: In 34/52 (65.4%) of the cases the correct diagnosis was primarily stated by CT (sensitivity [se.] 85.2%, specificity [sp.] 44.0%). In additional 10/52 of the cases unenhanced MRI (se. 91.4%, sp. 75.0%) enabled correct diagnoses, and in another 6 cases the diagnosis was established only by SPIO-MRI (se. 100%, sp. 86.7%). Considering the possible therapeutic recommendation arising from each modality, CT would have induced needless therapy costs of 191,042 DM, unenhanced MRI of 171,035 DM, and SPIO-MRI of 7,311 DM. In comparison to the real therapy costs of 221,873 DM, this would have corresponded to an unnecessary increase of therapy costs of 86.1%, 77.1%, and 3.3%, respectively. In two cases (91 ...

2000-03-01

352

Helical CT defecography  

International Nuclear Information System (INIS)

The purpose of this work is to investigate the possible role of Helical CT defecography in pelvic floor disorders by comparing the results of the investigations with those of conventional defecography. The series analyzed consisted of 90 patients, namely 62 women and 28 men, ranging in age 24-82 years. They were all submitted to conventional defecography, and 18 questionable cases were also studied with Helical CT defecography. The conventional examination was performed during the 4 standard phases of resting, squeezing, Valsalva and straining; it is used a remote-control unit. The parameters for Helical CT defecography were: 5 mm beam collimation, pitch 2, 120 KV, 250 m As and 18-20 degrees gantry inclination to acquire coronal images of the pelvic floor. The rectal ampulla was distended with a bolus of 300 mL nonionic iodinated contrast agent (dilution: 3g/cc). The patient wore a napkin and was seated on the table, except ...

1999-11-01

353

Fracture toughness characterisation in the ductile-to-brittle transition and upper shelf regimes using pre-cracked Charpy single-edge bend specimens  

International Nuclear Information System (INIS)

Fracture toughness data of pre-cracked Charpy single-edge bend, SE(B), specimens are compared with those of standard compact, C(T), specimens in the upper shelf and ductile-to-brittle transition regimes. Charpy sized SE(B) specimens provide ductile fracture toughness data, which are compatible with those of standard C(T) specimens. Statistical methods such as the exponential curve fitting method (ECF), the engineering lower bound toughness method (ELB), and the Master Curve method (MC) are used to provide meaningful lower bound cleavage fracture toughness estimates from the toughness scatter of the Charpy sized SE(B) specimens in the ductile-to-brittle transition regime. In this regime, according to the ELB and MC methods, SE(B) specimens provide cleavage toughness data, which tend to be non-conservative compared to those of standard C(T) specimens. However, analyses based on the exponential curve fitting method show good ...

2005-08-01

354

Experimental parameters differentially affect the humoral response of the cholera-toxin-based murine model of food allergy  

DEFF Research Database (Denmark)

Background: Recent studies have developed a murine model of IgE-mediated food allergy based on oral coadministration of antigen and cholera toxin (CT) to establish a maximal response for studying immunopathogenic mechanisms and immunotherapeutic strategies. However, for studying subtle immunomodulating factors or factors effective during response initiation, this maximal response-based model is less suitable due to a lack of sensitivity. Therefore, in attempts to identify essential parameters to fine-tune the immune response towards a submaximal level, potentially more sensitive, we were interested in characterizing the individual effects of the parameters in the CT-based model: CT dose, antigen type and dose, and number of immunizations. Methods: BALB/c mice were orally sensitized weekly for 3 or 7 weeks with graded doses of CT and various food antigens (soy-trypsin inhibitor, ovalbumin or ovomucoid). ...

2003-01-01

355

Autoregressive model-based compensation method for the saturated secondary current of a current transformer  

Energy Technology Data Exchange (ETDEWEB)

This paper presented a technique to compensate for distorted secondary currents. Since current distortion can cause operating time delays in protective relays, attempts are made to minimize current transformer (CT) saturation by choosing a CT with a voltage rating that is at least twice that required for the maximum steady-state symmetrical fault current. However, the possibility of saturation still exists because of the DC component of an asymmetrical fault current and the remanent flux in a CT core. An advanced algorithm for the compensation of the distorted signal due to CT saturation was proposed. The secondary current can be expressed as the linear combination of sinusoidal and exponential signals, if no saturation occurs. In this study, the algorithm first utilized the third difference function for detecting the start and end of saturation in real-time. The AR model-based FIR filter and the least ...

2006-07-01

356

Early detection by sup(99m)Tc-Sn-pyrophosphate scintigraphy of femoral head necrosis following medial femoral neck fractures  

International Nuclear Information System (INIS)

A selected series of 24 patients with displaced medial femoral neck fracture, treated with closed reduction and osteosynthesis with cancellous bone screws (ASIF), were investigated. During an observation period of 6 to 26 months, serial hip joint scintigraphies were performed and compared with serial X-ray examinations. At the first scintigraphic examination performed on average 5-6 weeks after the fracture, two separate investigators found a decreased amount of activity or no activity in the femoral head of 10 and 8 patients, respectively. At the second scintigraphic examination performed on average 11.1 weeks after the fracture both investigators found no activity or a decreased amount of activity in 8 patients. This figure declined to 7 during the following period, because one patient with decreased activity was recorded as having normal activity 15 months after the fracture. These 7 patients all developed radiological signs of femoral head ...

357

MRT versus CT in the diagnosis of pneumonia. Evaluation of a T{sub 2}-weighted utrafast turbo-spin-echo sequence (UTSE); MRT versus CT in der Diagnostik von Pneumonien. Evaluation einer T{sub 2}-gewichteten ultraschnellen Turbo-Spin-Echo-Sequenz (UTSE)  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate a T{sub 2}-weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T{sub 2}-weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR{sub eff}/T{sub E}/Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis and representation of the lesions, in 25% MRT was superior. MRT was better for the detection of pulmonary ...

1999-05-01

358

Wilsonville Advanced Coal Liquefaction Research and Development Facility, Wilsonville, Alabama. Topical report No. 10, thermal stress analysis  

Science.gov (United States)

The thermal dissolver, the main reactor of the SRC unit, has suffered a recurring problem. Specifically, it has been observed that whenever the reactor vessel is cooled to below 400/sup 0/F, its bottom head gasket leaks. An analysis of the thermal stress induced in the gasket, owing to transients across the bottom head flange, was sought. The analysis was facilitated by judiciously dividing a symmetric section of the reactor into 79 differential elements. Heat balances have been developed around each element. A numerical technique, the backward finite-difference approach, was employed to obtain the thermal behavior across the bottom head flange as a function of reactor heat-up time. The analysis performed affords an explanation for the failure of the gasket. Based on results of this work, recommendations have been suggested to provide the gasket and bolt stress requirements that are necessary to avoid leaks due to ...

1983-08-01

359

Variable-speed generation enhances hydro operation  

Energy Technology Data Exchange (ETDEWEB)

Two major developments have given impetus to wider adoption of variable-speed turbine/generators in hydroelectric plants, both essentially environmental: (1) the need for stream-bed stability below river dams, and (2) the need to minimize fish damage. Also, the need to stabilize pumped-storage and generating efficiencies to match extreme changes in head levels has been a driving force. Variable-speed operation in hydro applications is relatively new to North America. In other parts of the world, it has been used in pumped-storage plants since 1971. In the US, and increasing potential exists for variable-speed hydro, considering the 30 pumped-storage plants already in operation and several river plants struggling with high head fluctuations--including four at stations operated by the Bonneville Power Administration. Several modifications to hydro-plant hardware and operating procedures are actively being considered at Bonneville--all of them ...

1993-07-01

360

Quantitative assessment of bone scintigraphy in the hip joint disease  

International Nuclear Information System (INIS)

Quantitative assessment of bone scintigraphy was performed in fifty-six patients with hip joint disease including femoral neck fracture, aseptic necrosis of the femoral head, traumatic dislocation of the hip, Perthes disease, and transient synovitis of the hip. In the static study, bone scintigraphy was obtained 3 hours after injection of sup(99m)Tc-MDP by gamma camera equipped with a computer and uptake ratios were calculated. In the dynamic study, bone scintigraphy was performed in one, 3 and 5 hours after injection of radionuclide. Femoral head uptake ratio was markedly decreased in osteonecrosis following femoral neck fracture and characteristically increased in aseptic necrosis of the femoral head but prolonged retention of sup(99m)Tc-MDP could be observed. Uptake ratios of epiphysis were decreased in Perthes disease but normal in transient synovitis of the hip. Static and dynamic study of bone scintigraphy may be ...

361

Program plan for development of underground hydroelectric pumped storage technology  

Science.gov (United States)

The Underground Hydroelectric Pumped Storage (UHPS) Program Plan describes in detail the planned activities and expected accomplishments in the conduct of UHPS technology development and validation envisioned in the 1976 to 1990 time frame. This document describes the program objectives, implementation strategy, and management methodology. The concept of underground hydroelectric pumped storage is fully directed to application in the electric utility industry. This technology involves using electrical energy generated by base-load plants during off-peak load periods to drive a high-head pump/turbine which pumps water from a lower reservoir to a substantially elevated (upper) reservoir corresponding to a head of 1000 m or so. The upper reservoir is at ground level and the lower reservoir is below ground. Then, during peak-load periods, water in the upper reservoir is allowed to flow to the lower reservoir which, in turn, drives a hydraulic ...

1976-03-01

362

Non-hematological tumors of head and neck region in the pediatric age group in a tertiary care cancer center  

British Library Electronic Table of Contents (United Kingdom)

Purpose To analyze the clinical profile, management and outcome of non-hematological tumors in head and neck region in children less than 18?years of age. Patients and methods Medical records of patients (0?18?years) presenting with non-hematological tumors of head and neck region from 2000 to 2010 were reviewed. Result Out of the 78 patients identified, 50 were males with median age of 14?years (3?months to 18?years). Histologically, 58 out of the 78 patients had malignant tumors and 20 were metastatic at presentation. Common site of tumor origin was noted as thyroid (23/78), salivary glands (21/78) and nasopharynx (13/78). Out of 78 patients, 44 patients were treated by surgery, 26 patients received radiation and 13 patients received chemotherapy, while 9 patients received radio-iodine (...

2011-01-01

363

Low field magnetic resonance imaging of femoral neck fractures  

International Nuclear Information System (INIS)

Fourteen patients with cervical hip fractures were treated with internal fixation using titanium screws. The femoral head vitality was evaluated with "9"9Tc"m-MDP scintigraphy and scintimetry within 2 weeks postoperatively and by serial low field magnetic resonance imaging (MR). Two patients with reduced radionuclide uptake (femoral head ratio =# 1.0), MR revealed a focal decrease of the signal intensity in the femoral head or neck at 2, 3 and 7 months after fracture, respectively. The radiographs in one of these patients were normal at 7 months after fracture. The second one showed signs of necrosis at 16 months and the last one developed delayed/non-union. With a non-ferromagnetic osteosynthesis the healing course after femoral neck fracture can be studied with low field MR equipment without disturbing artifacts. The time period between ischaemia and definite abnormalities on MR may embrace several months. (orig.).

364

Device for removing drilling fines from a well head  

Energy Technology Data Exchange (ETDEWEB)

The device for removing drilling fines from the well head includes a support disk encompassing the sucker rod of the drilling machine with frame made in the form of a dish with inner conical surface, and overturned truncated cone located in the dish of the support disk with the formation between them of a ring guide slit. In order to improve the effectiveness of removing the drilling fines and convenience of operation by excluding heavy manual auxiliary operations to clean the well head and to move the device from one well to another, it is equipped with a mechanism for suspension with a drive. The inner conical surface of the dish is equipped with slide blocks, while the overturned truncated cone is equipped with projections. The suspension mechanism is made in the form of a hydrocylinder and two pairs of levers connected in pairs by means of hinges. The hinges of each pair of levers are connected to the hydrocylinder, and the levers are ...

1982-01-01

365

CT-guided injection for ganglion impar blockade: a radiological approach to the management of coccydynia  

International Nuclear Information System (INIS)

Aim: To evaluate the role of computed tomography (CT) in needle placement for ganglion impar blocks, and to determine the efficacy of CT-guided ganglion impar blocks in the management of coccydynia. Materials and methods: The results of ganglion impar blockade in eight patients with coccydynia secondary to trauma or unknown cause were reviewed. The diagnosis of coccydynia was based on clinical history, location of pain, and response to previous diagnostic and therapeutic procedures. The eight patients were treated with CT-guided ganglion impar blocks to manage their coccyx pain after conservative procedures, including oral medication and cushions, failed to provide relief. All patients were subjected to ganglion impar blocks under a thin-section CT-guided technique for needle placement, using a mixture of bupivacaine and triamcinolone. The patients were followed-up for a period of 6-months. Results: ...

2010-01-01

366

Upper limb dysfunction following selective neck dissection: A retrospective questionnaire study  

British Library Electronic Table of Contents (United Kingdom)

Background. To determine total upper limb function following selective neck dissection over a mean follow-up of 1.6 years. Methods. A retrospective questionnaire study in a tertiary head and neck surgical unit. One hundred forty-eight patients who underwent selective neck dissection for head and neck cancer from January 2000 to December 2005 were invited to participate. The main outcome measure was ipsilateral upper limb dysfunction as measured by the Disability of Arm, Shoulder and Hand (DASH) questionnaire. Results. Sixty-five patients responded to the invitation to join the study from 148 invited. Despite accessory nerve conserving surgery for all the selective neck dissections studied, 23% reported no upper limb dysfunction, 54% reported mild upper limb dysfunction, 15% reported modera...

2009-01-01

367

Two-photon calcium imaging from head-fixed Drosophila during optomotor walking behavior  

British Library Electronic Table of Contents (United Kingdom)

Drosophila melanogaster is a model organism rich in genetic tools to manipulate and identify neural circuits involved in specific behaviors. Here we present a technique for two-photon calcium imaging in the central brain of head-fixed Drosophila walking on an air-supported ball. The ball's motion is tracked at high resolution and can be treated as a proxy for the fly's own movements. We used the genetically encoded calcium sensor, GCaMP3.0, to record from important elements of the motion-processing pathway, the horizontal-system lobula plate tangential cells (LPTCs) in the fly optic lobe. We presented motion stimuli to the tethered fly and found that calcium transients in horizontal-system neurons correlated with robust optomotor behavior during walking. Our technique allows both behavior ...

2010-01-01

368

Study on probability of failure for RPV nozzle region under severe accident conditions  

Energy Technology Data Exchange (ETDEWEB)

Most of previous study for creep rupture of RPV lower head under severe accident condition, have been focused on global failure of RPV lower head. In contract, the local failure of the RPV nozzle region has not been studied in detail. The existence and features of nozzle failure in LAVA-ICI specimen of KAERI and LHF-4 specimen of Sandia National Lab., are observed. It is confirmed that the nozzle failure of LHF-4 specimen is due to the hoop stress in the RPV. The tensile tests in various temperatures and the creep rupture tests in various temperatures and stresses, are accomplished. The finite element analysis for LAVA-ICI experiment was confirmed, and the stress and deformation analysis results are used in LAVA-ICI experiment. 17 refs., 34 figs., 3 tabs. (Author)

2001-04-01

369

Sizing pumps for slurries  

Energy Technology Data Exchange (ETDEWEB)

Slurry characteristics have a significant impact on centrifugal pump performance. For instance, as particle size increases or the percent solids concentration increases, pump head and efficiency decrease. Therefore, before a slurry pump is selected, it is important to define the slurry characteristics as accurately as possible. The effect of the slurry characteristics on the head and efficiency of the centrifugal pump will be emphasized (the effect on flowrate is less significant). The effect of slurry characteristics is more predominant in smaller pumps (with smaller diameter impellers) than in larger pumps. The data and relationship between the various slurry parameters have been developed from correlations and nomographs published by pump vendors from their field data and test results. The information helps to avoid specifying an undersized pump/motor assembly for slurry service.

1996-11-01

370

Role of cerebrospinal fluid pressure in the pathogenesis of glaucoma  

British Library Electronic Table of Contents (United Kingdom)

Abstract. The pathogenesis of normal (intraocular) pressure glaucoma has remained unclear so far. As hospital-based studies showed an association of normal-pressure glaucoma with low systemic blood pressure, particularly at night, and with vasospastic symptoms, it has been hypothesized that a vascular factor may play a primary role in the pathogenesis of normal-pressure glaucoma. That assumption may, however, be contradicted by the morphology of the optic nerve head. Eyes with normal-pressure glaucoma and glaucomatous eyes with high-intraocular pressure can show a strikingly similar appearance of the optic nerve head, including a loss of neuroretinal rim, a deepening of the optic cup, and an enlargement of parapapillary atrophy. These features, however, are not found in any (other) vascula...

2011-01-01

371

Resveratrol causes COX-2- and p53-dependent apoptosis in head and neck squamous cell cancer cells  

British Library Electronic Table of Contents (United Kingdom)

Cyclooxygenase-2 (COX-2) content is increased in many types of tumor cells. We have investigated the mechanism by which resveratrol, a stilbene that is pro-apoptotic in many tumor cell lines, causes apoptosis in human head and neck squamous cell carcinoma UMSCC-22B cells by a mechanism involving cellular COX-2. UMSCC-22B cells treated with resveratrol for 24 h, with or without selected inhibitors, were examined: (1) for the presence of nuclear activated ERK1/2, p53 and COX-2, (2) for evidence of apoptosis, and (3) by chromatin immunoprecipitation to demonstrate p53 binding to the p21 promoter. Stilbene-induced apoptosis was concentration-dependent, and associated with ERK1/2 activation, serine-15 p53 phosphorylation and nuclear accumulation of these proteins. These effects were blocked by ...

2008-01-01

372

NAME=\\  

Wastenet

...The RSPB: Great crested grebe A delightfully elegant waterbird with ornate head plumes which led to its being hunted for its feathers, almost leading to its extermination from the UK. E-mail to a friendE-newsletterContact us Home England Northern Ireland Scotland Wales About Overview Awards & recognition Contact us Facts and figures History How we are run Inspiring work Job vacancies Looking to the future Media centre Offices The RSPB view ...status: Green Listen Get Flash player Play sound 1 videoLatin name Podiceps cristatusFamily Grebes (Podicipedidae)Overview A delightfully elegant waterbird with ornate head plumes which led to its being hunted for its feathers, almost leading to its extermination from the UK. They dive to feed and also to escape, preferring this to flying. On land they are clumsy because their feet are placed so far back on their bodies. ...

373

Literary Lives and a Literal Death: Yajnavalkya, Sakalya, and an Upaniṣadic Death Sentence  

British Library Electronic Table of Contents (United Kingdom)

One of the most popular stories found in the Upani?ads centers around a debate between the ritualist and philosopher, Yajnavalkya, and a series of interlocutors about the nature of sacrifice, the self, and the cosmos. This story, from a textual-historical perspective, is unique in that the last interlocutor, Sakalya, is said to die by having his head shatter because he is unable to answer a question about the fundamental nature of immortality. In this paper, I analyze the interrelationship of these two main characters and argue that this relationship is one key to not only understanding the portrayal of these characters, but also the larger import of this debate about immortality. I provide an intratextual rationale for the head-shattering conclusion and discuss how character and d...

2011-01-01

374

Joule-Thomson cryogenic cooler with extremely high thermal stability  

Science.gov (United States)

An 80-K Joule-Thomson (J-T) cooling system designed for the Probe Infrared Laser Spectrometer (PIRLS) proposed for the Huygens Titan Probe of the Cassini Saturn orbiter mission is presented. The cryogenic cooling requirements of the PIRLS instrument are listed, and the cooler system design including details of a J-T cryostat, cold head, and dewar design is described along with the results of a thermal modeling effort and lab cooler performance testing. It is shown that by using active feedback temperature control of the cold head in combination with the self-regulating action of the J-T cryostat, a temperature stability of less than 0.1 mK/min is achieved by the cooler weighting 1.8 kg.

1991-06-01

375

Effect of postharvest water deficit stress on gene expression in heads of broccoli (Brassica oleracea var. italica)  

British Library Electronic Table of Contents (United Kingdom)

Harvested plant organs such as heads of broccoli (Brassica oleracea L. var. italica) experience a range of stresses that can lead to premature reduction in quality and eventual senescence. Understanding plant responses to stress may open up novel opportunities to extend postharvest life. One of the first stresses experienced by harvested organs is likely to be water deficit stress since severance of the vascular system halts the normal flux of water into the tissue. For broccoli branchlets with their cut ends held in water, transcriptome analysis based on hybridization of broccoli floret mRNA to a heterologous Arabidopsis microarray revealed that the transcript abundance of 431 genes reliably changed within 48h of harvest. Of these, transcripts of 146 genes increased and 34 genes decreased...

2011-01-01

376

Design of aircraft-carried sampling system for aerial radioactivity monitoring  

International Nuclear Information System (INIS)

This paper presents the development of technical requirements for the design of aircraft-mounted sampling equipment for the airborne radioactivity monitoring. A design concept and internal equipments required for the sampling system will be described in detail to provide information for the development of technical requirements for aircraft-mounted sampling equipment. This will be followed by description of the exterior designing process. Difficulties of designing exterior of the sampling system lie in the fluid dynamics performance of the system. The objective of the design is to maximize the suction flow necessary for achieving high efficiency of radionuclide sampling, while minimizing disturbance to the aircraft which carries the system. The design optimization was performed with the computational fluid dynamics (CFD) code FLUENT. The design options considered here were (1) diameter to head ratio of top and back head, (2) nozzle length and ...

2009-03-01

377

Design of Reactor Head Structure Assembly Using Axiomatic Design  

Energy Technology Data Exchange (ETDEWEB)

The Reactor Head Structure Assembly(RHSA) is the structure located on the reactor assembly. The purpose of the assembly is providing interface location for cables, preventing pipe whips, prohibiting instruments from becoming missiles, and restraining CEDMs' horizontal motion. On the RHSA, Reactor Disconnect Panels(RDP) are installed. The installation location of RDP is to be decided to minimize the geometric interface with other components. Since the neighborhood of RHSA is crowded due to many connectors and cables, it is necessary to find the good design of RHSA to make an intricate situation attenuated and the required function maintained. The geometric shape and overall configuration of RHSA are determined by axiomatic design approach. The FRs of RHSA are specified and the corresponding DPs are found to satisfy FRs in sequence. The finite element analysis is carried out based on the result of the axiomatic design to evaluate the structural integrity.

2007-07-01

378

Correlation of MRI and histomorphological findings in bone marrow oedema syndrome of the hip  

Energy Technology Data Exchange (ETDEWEB)

In 15 patients (16 hip joints) we found the clinical and radiological signs of BMOS. On T1-weighted MRI images areas of low signal intensity could be observed in the head, neck and the intertrochanteric region of the femur in various extensions. These areas showed a significant increase in signal intensity on the T2-weighted images. Because pain was resistant to conservative therapy all these patients were treated by core decompression of the femoral head in a prospective study. Bone cores were evaluated histologically using undecalcified sections and quantitative microradiography. The existence of intramedullary oedema in exactly the regions exhibiting the MRI pattern of bone marrow oedema was verified histologically; however, bone and marrow changes similar to those of early avascular necrosis (AVN) were also visible. (orig.)

1993-10-01

379

Apparatus for in situ determination of burnup cooling time and fissile content of an irradiated nuclear fuel assembly in a fuel storage pond  

Energy Technology Data Exchange (ETDEWEB)

A detector head for in situ inspection of irradiated nuclear fuel assemblies submerged in a water-filled nuclear fuel storage pond. The detector head includes two parallel arms which extend from a housing and which are spaced apart so as to be positionable on opposite sides of a submerged fuel assembly. Each arm includes an ionization chamber and two fission chambers. One fission chamber in each arm is enclosed in a cadmium shield and the other fission chamber is unshielded. The ratio of the outputs of the shielded and unshielded fission chambers is used to determine the boron content of the pond water. Correcting for the boron content, the neutron flux and gamma ray intensity are then used to verify the declared exposure, cooling time and fissile material content of the irradiated fuel assembly.

1985-04-09

380

Angiography of the head using Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Forty-seven subtraction images of FCR were compared with subtraction images of conventional angiography of the head. Quality of the FCR images were equal or superior to that of conventional angiography. Antero-posterior projection of external carotid arteriography by FCR was most useful because of its wide dynamic range. As contrast resolution of FCR is superior to that of conventional angiography, only half diluted contrast media was needed. As for spacial resolution, FCR is slightly inferior to conventional angiography. However, most vessels which are clinically important were adequately demonstrated. A weak point of FCR which should be improved is relatively long time to process the images after radiation exposure. (author).

1985-01-01

381

Reliability of diagnostic imaging techniques in suspected acute appendicitis: proposed diagnostic protocol; Indicacion de las tecnicas de diagnostico por la imagen en la sospecha de apendicitis aguda: propuesta de protocolo diagnostico  

Energy Technology Data Exchange (ETDEWEB)

To study the utility of ultrasound and computed tomography (CT) in case of suspected appendicitis. To determine the diagnostic yield in terms of different clinical contexts and patient characteristics. to assess the costs and benefits of introducing these techniques and propose a protocol for their use. Negative appendectomies, complications and length of hospital stay in a group of 152 patients with suspected appendicitis who underwent ultrasound and CT were compared with those of 180 patients who underwent appendectomy during the same time period, but had not been selected for the first group: these patients costs for each group were calculated. In the first group, the diagnostic value of the clinical signs was also evaluated. The reliability of the clinical signs was limited, while the results with ultrasound and CT were excellent. The incidence of negative appendectomy was 9.6% in the study group and 12.2% in the ...

2001-07-01

382

Preoperative staging of rectal carcinoma with combined sonography and pelvic computed tomography  

International Nuclear Information System (INIS)

The accurate staging of rectal carcinoma is very important for treatment planning. The histological data obtained from surgical specimens of 22 patients with rectal carcinoma were compared with pre-and postoperative endorectal US findings and with preoperative CT results. According to an adapted version of Astler and Coller classification, the different degrees of tumor spread into the rectal wall were represented as follows: stage A: 1 patient; stage B1: 5 patients; stage B2: 6 patients; stage C1: 1 patient; stage C2: 8 patients and stage D: 1 patient. Preoperative staging, based on the overall results of CT and US, was in agreement with histology in 19 of 22 cases. Individual analysis of US and CT results, in comparison with histological data, showed US staging accuracy to be 77.3% (17/22 patients). US accuracy in demonstrating tumor spread into the rectal wall (stages A, B1, C1) was 100% (7/7 patients); US was 70% ...

1991-01-01

383

Normal development of paranasal sinuses in children: A CT study  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the normal development of the paranasal sinuses in children with CT, authors prospectively studied with brain CT scans of 260 children without known sinus disease, ranging image from 7 days to 16 years. Maximal anteroposterior and transverse diameters(mm) and maximal cross- sectional area(mm{sup 2}) of both sides of the maxillary sinus were measured with the aid of computer device. As to the ethmoidal and spheroidal sinuses, we simply documented the presence of the aplastic ethmoidal sinus and calculated the age-incidence of the spheroidal sinus pneumatization, respectively.There noted three phases in the development of the maxillary sinus. The anteroposterior and transverse diameters of the maxillary sinus increased nearly in parallel. The former was always greater than the latter. In no cases was the edathamil sinus aplastic and almost all sinuses were pneumatized even in infants as early as 7 old days. CT ...

1993-11-15

384

Intrahepatic peripheral cholangiocarcinoma; dynamic features of CT scans  

International Nuclear Information System (INIS)

To elucidate the dynamic features of CT scans in peripheral cholangiocarcinoma for the differentiation of this tumor from various primary hepatic neoplasms. Materials were 24 cases of pathologically confirmed peripheral cholangiocarcinoma. Contrast enhancement patterns of central and peripheral portion of the masses were analyzed at three phases including arterial dominant(22), tissue equilibria(24), and postequilibria(9). Other associated CT findings and laboratory data were analyzed. Serum total bilirubin was mostly below 2 mg/dl(22/24), hepatitis B surface antigen was positive in only 9%, serum alphafetoprotein was elevated in 18%, carcinoembryonic antigen in 47%, cancer antigen 19-9 in 60%. In the arterial dominant image(22), 50% of the cases showed peripheral hyperdensity and 50% total hypodensity. In the tissue equilibrial images(24), 63% showed total hypodensity, 25% peripheral hyperdensity, and 13% total isodensity. In the ...

1995-05-01

385

Fecal incontinence in operated cases for anorectal malformations  

International Nuclear Information System (INIS)

In spite of great progress in surgical treatment of anorectal malformations, fecal incontinence is still, in variable degrees, a frequent and unpleasant postsurgical sequela. The most frequent causes of incontinence are: 1) the incorrect placement of the pulled-through colon in the levator ani and sphincteric muscular complex during abdomino-perineal surgical procedures; 2) the poor development of sphinteric musculature; 3) the associated sacral anomalies. Postoperative CT helps to evaluate all the above-mentioned conditions, in view of possible new surgical procedure for improving continence (besides postoperative CT can help in choosing the more suitable surgical technique). Nine patients, aged 3 to 13 years (2 with good continence and 7 with various degrees of incontinence), were studied with pelvic postoperative CT. In the cases (2) with good continence the CT picture was: good development of ...

1989-01-01

386

Computer modelling of eddy current probes for ISI of pressure tube/calandria tube assemblies in PHWRs  

International Nuclear Information System (INIS)

Non-destructive Evaluation (NDE) plays a major role in ensuring the safe and reliable operation of PHWRs which are the mainstay of India's nuclear power programme. An important in-service inspection (ISI) requirement in these reactors is carried out through Eddy Current Testing (ECT) of the pressure tube (PT)/calandria tube (CT) assemblies. The material of construction of these assemblies is zircaloy-2. The two main objectives of this ISI are the detection of garter spring between CT and PT and the profiling of gap between CT and PT. The paper discusses the work carried out at the authors' laboratory on the development of ECT probes for ISI of PT/CT assemblies. Emphasis has been given on the work done on the design and optimisation of the probes using computer modeling. A 2-D finite element code has been developed for this purpose. The code is developed around a diffusion equation which can be derived ...

1991-12-01

387

Computed tomography in the diagnosis of cavum septum pellucidum  

Energy Technology Data Exchange (ETDEWEB)

The cavum septum pellucidum is an anatomical variants of the septum pellucidum, and lying between two lateral ventricles and this is referred to as the fifth ventricle. Occasionally, posterior extension of the cavum septum pellucidum towards the splenium is seen and this is known as the cavum vergae, or sixth ventricle. The septum is double membrane and occasionally a narrow cavity containing CSF is present between these membrane. The roof of the cavum septum pellucidum is formed by the corpus callosum and its floor by the anterior pillars of the fornix. This cavum outlined with air is occasionally seen in the pneumoencephalography. Brain CT scans of 1000 patients were performed, and the diagnosis could be made on the basis of the characteristic shape, density and location. Other diagnostic procedure are not necessary in these cases. Patients were examined with CT scanner from June-80' to Dec-80', at department of radiology, ...

1981-09-15

388

Computed Tomography in the study of pulmonary tuberculosis  

International Nuclear Information System (INIS)

The authors carried out a retrospective study on 4 years' work on a series of patients with proved active tuberculosis examined in the Departments of Bronchopneumology and Infectious Disease of the Arezzo Civil Hospital. The population was heterogenerous from the immunologic viewpoint. This paper compared the effectiveness of Computed Tomography (CT) with that of conventional chest radiography (CR) in the diagnosis and prognosis of tuberculosis. All patients underwent chest CR in double projection and conventional CT studies of the chest; 16 patients were also submitted to high resolution CT (HRCT). Consolidation was the most frequent parenchymal lesion in immunocompetent patients; it was often associated with cavitation, with no clear topographic prevalence in the upper lobes. Pleural effusion, as the only sign of disease and with empyema features, was found in 10 immunocompetent patients. No predominant pattern was found ...

1997-01-01

389

Cerebral blood flow measurement using stable xenon CT with very short inhalation times  

Energy Technology Data Exchange (ETDEWEB)

A noninvasive, simplified method using inhalation of stable xenon (Xe{sup s}) and computed tomographic (CT) scanning to estimate regional cerebral blood flow (rCBF) and regional partition coefficient (r{lambda}) is described. Twenty-four patients with cerebrovascular occlusive disease and six volunteer controls inhaled 30% Xe{sup s} and 70% oxygen for 180 seconds and exhaled for 144 seconds during serial CT scanning without denitrogenation. The end-tidal Xe{sup s} concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) for arteries with the curve fitting method. The time-CT number (Hounsfield unit) curve for cerebral tissue during the Xe{sup s} washin and washout phases was used to calculate r{lambda} and rCBF using least squares curve fitting analysis. The resultant r{lambda} and rCBF map demonstrated a reliable distribution ...

1991-02-01

390

Cerebral blood flow measurement using stable xenon CT with very short inhalation times  

International Nuclear Information System (INIS)

A noninvasive, simplified method using inhalation of stable xenon (Xe"s) and computed tomographic (CT) scanning to estimate regional cerebral blood flow (rCBF) and regional partition coefficient (r#lambda#) is described. Twenty-four patients with cerebrovascular occlusive disease and six volunteer controls inhaled 30% Xe"s and 70% oxygen for 180 seconds and exhaled for 144 seconds during serial CT scanning without denitrogenation. The end-tidal Xe"s concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) for arteries with the curve fitting method. The time-CT number (Hounsfield unit) curve for cerebral tissue during the Xe"s washin and washout phases was used to calculate r#lambda# and rCBF using least squares curve fitting analysis. The resultant r#lambda# and rCBF map demonstrated a reliable distribution between the gray and ...

391

Can simulation measurements be used to predict the irradiated lung volume in the tangential fields in patients treated for breast cancer  

Energy Technology Data Exchange (ETDEWEB)

A simple method of estimating the amount of lung irradiated in patients with breast cancer would be of use in minimizing lung complications. To determine whether simple measurements taken at the time of simulation can be used to predict the lung volume in the radiation field, we performed CT scans as part of treatment planning in 40 cases undergoing radiotherapy for breast cancer. Parameters measured from simulator films included: (a) the perpendicular distance from the posterior tangential field edge to the posterior part of the anterior chest wall at the center of the field (CLD); (b) the maximum perpendicular distance from the posterior tangential field edge to the posterior part of the anterior chest wall (MLD); and (c) the length of lung (L) as measured at the posterior tangential field edge on the simulator film. CT scans of the chest were performed with the patient in the treatment position with 1 cm slice intervals, covering lung apex ...

1990-01-01

392

CT findings of intrahepatic cholangiocarcinoma associated with hepatolithiasis  

International Nuclear Information System (INIS)

To assess the CT findings of intrahepatic cholangiocarcinoma associated with hepatolithiasis. The CT features of 26 patients with cholangiocarcinoma and hepatolithiasis were reviewed and compared with those of 23 patients with intrahepatic stones alone, acting as control subjects. CT findings were analyzed for tumor appearance and adjacency to hepatolithiasis. We studied clinical findings, noting the presence or absence of wall thickening or soft tissue attenuation within the bile duct, the luminal diameter of dilated bile duct, and the presence of periductal enhancement, and compared these with the findings for control groups. CT images of the tumor revealed a hepatic low-attenuating mass with peripheral rim enhancement(n = 14,54 %), or periductal thickening, or low-attenuating lesions in segmental dilatation of intrahepataic bile ducts(n = 12, 46 %). Most hepatic tumors were seen in areas adjacent to ...

1999-09-01

393

CT colonography with minimal bowel preparation: evaluation of tagging quality, patient acceptance and diagnostic accuracy in two iodine-based preparation schemes  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to compare a 1-day with a 2-day iodine bowel preparation for CT colonography in a positive faecal occult blood test (FOBT) screening population. One hundred consecutive patients underwent CT colonography and colonoscopy with segmental unblinding. The first 50 patients (group 1) ingested 7*50 ml iodinated contrast starting 2 days before CT colonography. The latter 50 patients (group 2) ingested 4*50 ml iodinated contrast starting 1 day before CT colonography. Per colonic segment measurements of residual stool attenuation and homogeneity were performed, and a subjective evaluation of tagging quality (grade 1-5) was done. Independently, two reviewers performed polyp and carcinoma detection. The tagging density was 638 and 618 HU (p = 0.458) and homogeneity 91 and 86 HU for groups 1 and 2, respectively (p = 0.145). The tagging quality was graded 5 (excellent) in 90% of all segments ...

2010-02-15

394

Anatomic variations on PNS CT  

Energy Technology Data Exchange (ETDEWEB)

To illustrate frequently encountered anatomic variations on PNS computed tomography(CT) and to assess their clinical significance. CT findings of 1523 patients, who underwent PNS CT with no history of sinus surgery, were reviewed, and prevalence of each anatomic variation and its relationship with mucociliary clearance pathway was evaluated. Two categories of anatomic variations were encountered. The first group included variations of the turbinates, such as concha bullosa(28.6%), paradoxical middle turbinate(31.5%), of the uncinate process, such as medially bent or folded(36.3%), laterally bent(3.7%) or uncinate bulla(0.5%), of the ethmoidal sinus, such as Haller's cell(28.2%), large agger nasi cell(9.6%) or large ethmoidal bulla(23.5%) and nasal septal deviation(24.1%), which might cause obstruction of mucociliary clearance pathway and thus give rise to secondary obstructive sinusitis. The second group included ...

1994-09-15

395

Anatomic variations on PNS CT  

International Nuclear Information System (INIS)

To illustrate frequently encountered anatomic variations on PNS computed tomography(CT) and to assess their clinical significance. CT findings of 1523 patients, who underwent PNS CT with no history of sinus surgery, were reviewed, and prevalence of each anatomic variation and its relationship with mucociliary clearance pathway was evaluated. Two categories of anatomic variations were encountered. The first group included variations of the turbinates, such as concha bullosa(28.6%), paradoxical middle turbinate(31.5%), of the uncinate process, such as medially bent or folded(36.3%), laterally bent(3.7%) or uncinate bulla(0.5%), of the ethmoidal sinus, such as Haller's cell(28.2%), large agger nasi cell(9.6%) or large ethmoidal bulla(23.5%) and nasal septal deviation(24.1%), which might cause obstruction of mucociliary clearance pathway and thus give rise to secondary obstructive sinusitis. The second group included Onodi ...

1994-09-01

396

AIDS and lung infection by Mycobacterium xenopi. Role of Computed Tomography  

International Nuclear Information System (INIS)

Mycobacterium xenopi is one of the most common agents responsible for nontubercolar mycobacterial pulmonary disease on AIDS patients. These lesions have been studied with conventional radiography while CT has been used in patients with a specific mycobacterioses or non-AIDS pulmonary conditions from Mycobacterium xenopi. 12 AIDS patients were examined. They had pulmonary lesions from Mycobacterium xenopi, patients age ranged 30 to 46 years. All patients had CD4 blood levels lower than 250 cells/mL and Mycobacterium xenopi in the sputum. All patients underwent a standard chest radiograph and a CT examination. CT images were evaluated by three radiologists independently and the definitive diagnosis was made in the presence of a fourth radiologist. Chest CT showed parenchymal consolidation in 66% of cases, associated with bilateral basal bands in 16% of cases. Consolidation was unilateral in 41% of cases ...

2000-06-01

397

A comparison of x-ray detectors for mouse CT imaging  

International Nuclear Information System (INIS)

There is significant interest in using computed tomography (CT) for in vivo imaging applications in mouse models of disease. Most commercially available mouse x-ray CT scanners utilize a charge-coupled device (CCD) detector coupled via fibre optic taper to a phosphor screen. However, there has been little research to determine if this is the optimum detector for the specific task of in vivo mouse imaging. To investigate this issue, we have evaluated four detectors, including an amorphous selenium (a-Se) detector, an amorphous silicon (a-Si) detector with a gadolinium oxysulphide (GOS) screen, a CCD with a 3:1 fibre taper and a GOS screen, and a CCD with a 2:1 fibre taper and both GOS and thallium-doped caesium iodide (CsI:Tl) screens. The detectors were evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), detective quantum efficiency (DQE), stability over multiple exposures, and noise in reconstructed ...

2004-12-07

398

Spatial distribution of opsin-encoding mRNAs in the tiered larval retinas of the sunburst diving beetle Thermonectus marmoratus (Coleoptera: Dytiscidae)  

UK PubMed Central (United Kingdom)

Larvae of the sunburst diving beetle, Thermonectus marmoratus, have a cluster of six stemmata (E1-6) and one eye patch on each side of the head. Each eye has two retinas: a...Full Text Available

2009-12-01

399

Some optimization measurements and parameters of a radionuclide X-ray fluorescence spectrometer  

International Nuclear Information System (INIS)

An irradiation head with sample holders is described and measurement geometry is reported. Measurements were made for optimizing the distance between the source and the sample and for optimizing the sample diameter. The optimal distance between the source and the sample does not depend on the collimator diameter. The sample diameter should not exceed 30 - 35 mm. Sensitivity and detection limits were determined for Zn, Pb and Br and calibration curves were plotted. (M.D.) 6 figs., 2 tabs., 4 refs.

1986-01-01

400

Small-scale hydroelectric power demonstration project: Boott Hydropower, Inc. Eldred L. Field Hydroelectric Project: Final technical and construction cost report  

Energy Technology Data Exchange (ETDEWEB)

The Lowell Hydroelectric Project (Eldred L. Field) is a key feature of the Departments of Energy's National Low Head Hydroelectric Power Demonstration Program. This report summarizes the Project's Construction which began in October 1983 and was completed in November 1985. It also details project construction costs.

1988-03-01

401

Sequential changes in the femoral head after intracapsular fracture of the femoral neck. MRI findings  

International Nuclear Information System (INIS)

Authors obtained T1-weighted MRI images of the femoral head after fracture of the femoral neck and classified the signals into four patterns to investigate the sequential changes of the femoral head. The T1-weighted MRI images obtained initially after femoral neck fracture showed a normal pattern in 10 of the 15 hip joints studied. MRI images obtained subsequently still showed the normal signal pattern in eight of the 10 hip joints which had shown the normal pattern in the first MRI, while two of the 10 joints subsequently showed a band pattern. The joint with the homogeneous pattern in the first MRI subsequently showed a band pattern. Of the three joints with an inhomogeneous pattern in the first MRI, two joints showed a subsequent band pattern, and the other a normal pattern. The joints which showed a band pattern continued to show a similar band pattern. Eventually, all hip joints studied showed a normal or band pattern within six months ...

1998-07-01

402

Radiations against tumors: a bit old-fashioned?; Rayonnements contre tumeurs: un rien demode?  

Energy Technology Data Exchange (ETDEWEB)

The proton therapy gives an irradiation adapted to the shape and the depth of tumors ( eyes, head and neck) with a millimetric, even sub millimetric precision for the ophthalmological tumors. It is equally an excellent tool for the pediatrics tumors. For numerous treatments in France the proton therapy is associated to the photons treatments (x radiation). however, others physical treatments could modulate the medical offer, such thermal therapy or treatments by ultrasonic waves. (N.C.)

2004-09-01

403

Quantitative Trait Loci for Grain Yield and Adaptation of Durum Wheat (Triticum durum Desf.) Across a Wide Range of Water Availability  

UK PubMed Central (United Kingdom)

Grain yield is a major goal for the improvement of durum wheat, particularly in drought-prone areas. In this study, the genetic basis of grain yield (GY), heading date (HD), and plant height (PH) was...Full Text Available

2008-01-01

404

Proceedings, international symposium on mine mechanization and automation  

Energy Technology Data Exchange (ETDEWEB)

Papers are presented under the session headings: research in mechanical fragmentation; rock characterization, remote sensing and interface detection; monitoring, data transmission and communications; tunnel boring machines; minewide monitoring and expert systems for ground control; machine guidance; shaft and raise boring; automation of drilling equipment; machine automation and control; new developments in mechanical miners; materials handling; innovative mining systems; general minewide monitoring and expert systems; ground support; human factors; and extraterrestrial mining.

1991-01-01

405

Proceedings of the 1991 ASME JSME thermal engineering joint conference  

International Nuclear Information System (INIS)

This book is organized under the following headings: Electrohydrodynamic heat transfer augmentation; Forced convection augmentation and heat transfer control; Turbulent heat transfer; Thermal problems in the environment; Energy conversion systems; Measurement, visualization, and imaging; Thermal problems in space technology; and Thermal properties.

1991-03-17

406

Practical approach to the loss of smell  

Energy Technology Data Exchange (ETDEWEB)

Loss of the sense of smell can be easily confirmed in any physician's office by having the patient try to identify various odors. The etiology of anosmia can be extremely varied, including nasopharyngeal disorders such as rhinitis and tumors; neurologic conditions such as head trauma, neoplasms, vascular lesions and infections of the central nervous system; viral infections; familial and congenital disorders; drugs; industrial exposure; endocrine diseases, and several other disorders. The prognosis of anosmia is guarded, and its treatment depends on the etiology.

1982-09-01

407

PU.1 is a major transcriptional activator of the tumour suppressor gene LIMD1  

UK PubMed Central (United Kingdom)

LIMD1 is a tumour suppressor gene (TSG) down regulated in ∼80% of lung cancers with loss also demonstrated in breast and head and neck squamous cell carcinomas. LIMD1 is also a candidate TSG...Full Text Available

2011-04-06

408

Osteonecrosis in patients receiving dialysis: report of two cases and review of the literature.  

Science.gov (United States)

Two patients receiving maintenance dialysis therapy developed osteonecrosis, the first in the humeral head and the second in the talus. Both patients lacked known risk factors for developing osteonecrosis. A possible pathogenic role of secondary hyperparathyroidism in this disorder is suggested. Rheumatologists evaluating patients receiving maintenance dialysis with rheumatic manifestations should be aware of this potential complication. PMID:2185360

1990-03-01

409

Nuclear power generation. Chapter 14  

International Nuclear Information System (INIS)

As part of a handbook on the efficient use of energy a chapter is included which is intended to give an appreciation of the principles and problems involved in the generation of nuclear power. The subject is discussed under the following headings: introductory nuclear physics; basic reactor physics; thermal reactors; fast reactors; fuel reserves and utilization; environmental considerations; nuclear fusion. (U.K.).

1975-01-01

410

Monitoring of the Water Levels in the Wetlands of Fourmile Branch near the F and H Areas of SRS: January - December 2000  

Energy Technology Data Exchange (ETDEWEB)

In 2000, a network of twenty-three piezometers was used to measure hydraulic head in the water-table aquifer (Upper Aquifer Zone of the Upper Three Runs Aquifer, or UAZ of the UTRA) along the ground water outcrops (i.e. seeplines) near the F- and H-Areas.

2001-07-10

411

Model tests on a semi-axial pump turbine  

Energy Technology Data Exchange (ETDEWEB)

Due to their good hydraulic characteristic semi-axial pump turbines are used in the medium head range of pumped storage plants. This paper describes model tests performed on a semiaxial pump turbine model and shows the results of these tests. The aim of the model tests was the optimization of the hydraulic water passage, the measurement of the hydraulic characteristics over the whole operating range, the investigation of the cavitation behaviour, the investigation of the hydraulic forces and torques as well as the proof of the values guaranteed to the customer.

1984-03-01

412

Method for processing statistical information concerning sucker-rod pump unit operations  

Energy Technology Data Exchange (ETDEWEB)

The authors propose an integrated indicator of pump-rod couplings that allows both the couplings and the pump operations to be appraised according to the given formula. (Formula provided). The dynamic relationships of rod operations were determined with nomographs. These relationships involve such factors as: the type and size of the sucker-rod string; the pressure load at the equalizer head and its correlation to threshold pressure at pump discharge; pump diameter; the rod weight and construction; and integral reliability indicators.

1982-01-01

413

Johnston vows to head off gas proration ban  

International Nuclear Information System (INIS)

This paper reports that Sen. Bennett Johnston (D-La.) has vowed if Congress enacts an omnibus energy bill in the fall, it will not include a restriction on states' rights to proration natural gas production. Johnston, Senate energy committee chairman, will lead Senate conferees in their negotiations with members of the House of Representatives. The House energy bill has an antiproration amendment. The Senate's bill does not. Oklahoma's and Texas' recent actions to proration gas production prompted the federal legislation.

414

Jet cutting and cleaning bibliography  

Energy Technology Data Exchange (ETDEWEB)

This bibliography includes over 600 references (with abstracts) on all aspects of waterjet cutting and cleaning. The references are listed under the following chapter headings: fluid mechanics of jets; jet impact; equipment; jet cleaning; jet cutting; civil engineering; mining and tunnelling; precision cutting; underwater; safety; and bibliographies. Separate author and corporate source indexes are provided.

1988-01-01

415

How the Performance of a Superconducting Magnet is affected by theConnection between a small cooler and the Magnet  

Energy Technology Data Exchange (ETDEWEB)

As low temperature cryocoolers become more frequently used to cool superconducting magnets, it becomes increasingly apparent that the connection between the cooler and the magnet has an effect on the design and performance of the magnet. In general, the use of small coolers can be considered in two different temperature ranges; (1) from 3.8 to 4.8 K for magnet fabricated with LTS conductor and (2) from 18 to 35 K for magnets fabricated using HTS conductor. In general, both temperature ranges call for the use of a two-stage cooler. The best method for connecting a cooler to the magnet depends on a number of factors. The factors include: (1) whether the cooler must be used to cool down the magnet from room temperature, (2) whether the magnet must have one or more reservoirs of liquid cryogen to keep the magnet cold during a loss of cooling, and (3) constraints on the distance from the cooler cold heads and the magnet and its shield. Two methods for connecting low ...

2005-09-08

416

Genetic Control of Capsid Length in Bacteriophage T4 I. Isolation and Preliminary Description of Four New Mutants  

UK PubMed Central (United Kingdom)

Four new mutants are described whose phenotypic expression affects the length of the head of bacteriophage T4D. All mutants produce some phenotypically normal phage particles. Mutant pt21-34...Full Text Available

1973-08-01

417

Expression Levels of Thymidylate Synthase, Thymidylate Phosphorylase and Dihydropyrimidine Dehydrogenase in Head and Neck Squamous Cell Carcinoma: Preliminary Study  

UK PubMed Central (United Kingdom)

IntroductionPharyngo-laryngeal tumors classified as T3-4, N0-3, M0, are conventionally treated by mutilating surgery (total (pharyngo)-laryngectomy). Neo-adjuvant chemotherapy with...Full Text Available

418

Electron linear accelerators for radiotherapy  

International Nuclear Information System (INIS)

Present-day requirements for radiotherapy equipment are considered. The recently developed linacs of LUE-5, LUE-25, LUE-15MM models, as well as a newly designed unified series of medical linacs of LUER-5M, LUER-20M, LUER-40M models are described in brief. The main scientific and technical problems that were solved during their construction, namely, development of accelerating structures, a radiation head, dosimetry equipment, a programming unit, a magnetic mirror etc. are described.

1983-06-01

419

Earth Sciences Division annual report 1980  

Energy Technology Data Exchange (ETDEWEB)

Summaries of the highlights of programs in the Earth Sciences Division are presented under four headings; Geosciences, Geothermal Energy Development, Nuclear Waste Isolation, and Marine Sciences. Utilizing both basic and applied research in a wide spectrum of topics, these programs are providing results that will be of value in helping to secure the nation's energy future. Separate abstracts have been prepared for each project for inclusion in the Energy Data Base. (DMC)

1981-07-01

420

EFFECT OF SHIP ATTITUDE AND SHIP MOTION ON PRIMARY COOLANT SYSTEM FLOW RATES. Appendix A: DERIVATION OF EFFECT OF ANGULAR ACCELERATION ON DRIVING HEAD IN A NATURAL CIRCULATION REACTOR  

Science.gov (United States)

Analytical techniques for analyzing the effects of ship motion and attitude on the primary coolant system flow rates are presented. Design data for minimizing these effects are given. (C.J.G.)

1960-01-24

421

Cytology of a giant adult-type rhabdomyoma of the tongue  

British Library Electronic Table of Contents (United Kingdom)

Abstract Adult rhabdomyoma is a rare primary benign tumour of striated muscle origin that almost exclusively presents in the head and neck region with predilection for male. We herein report a case of an adult rhabdomyoma in a 67-year-old male with cytologic features. The lesions was located in the tongue extended to the left parapharyngeal region. We discuss the cytological findings with a brief review of the literature on this entity. Diagn. Cytopathol. 2010. 2010 Wiley-Liss, Inc.

2011-01-01

422

Crumbling case for nuclear power  

Energy Technology Data Exchange (ETDEWEB)

In connection with the Public Inquiry into the CEGB proposal to build a pressurised water reactor at Sizewell in Suffolk, the case for nuclear power is examined under the headings: the economics of nuclear power - how they would like them to be; systems analysis - net effective cost; CEGB prejudices the results (comparison with coal-fired plants; forecasting on various assumptions); discounting future costs; back-end costs soar (reprocessing); real reprocessing costs; AGR costs balloon.

1983-01-01

423

Combustion chamber layout for modern Otto engines  

Energy Technology Data Exchange (ETDEWEB)

Since the most efficient way to improve fuel economy in the part-load range is to increase the compression ratio, emphasis is placed on combustion chambers allowing high compression ratios combined with low octane requirements. According to Porsche experience, many demands can be met in the simplest manner by locating the combustion chamber in the piston crown. This configuration offers various advantages over its counterpart installed in the cylinder head. 24 refs.

1981-10-01

424

Bibliography of prosopis  

Energy Technology Data Exchange (ETDEWEB)

References covering the years 1904-80 are listed under the following headings: cultivation and occurrence (India and Pakistan, Africa, South America, Pacific, Middle East); Taxonomy, morphology, variation and selection; Reference works and reviews; Ecology of Prosopis (General effects on surrounding soil and vegetation): Physiology (General, Roots, Growth, Hydrology, Saline tolerance); Control of mesquite: Propagation (Germination and other nursery techniques, Vegetative propagation): and Utilization (General, Chemical analyses, Food and Ethnobiology, Fodder, Wood, Charcoal, Gum, Paper). 141 references.

1981-01-01

425

A brief history of the World Wide Web Where it as invented, how it's used, and where it's headed  

CERN Multimedia

The World Wide Web has its historical roots in things such as the creation of the telegraph, the launching of the Sputnik and more, but it really all started in March 1989, when Tim Berners-Lee, a computer scientist at CERN in Geneva wrote a paper called Information Management: A proposal

2005-01-01

426

Virtual colonoscopy (CT colonography) in the identification of colorectal cancer. A prospective study in symptomatic patients  

International Nuclear Information System (INIS)

Aim of this study was to evaluate the sensitivity of virtual colonoscopy (CT colonography) in the identification of colorectal cancer and to define the limitations and the advantages of this imaging modality, as well as indications to the examination. It was examined prospectively 62 symptomatic patients aged 36 to 82 years (28 women and 34 men). All patients underwent both conventional and virtual colonoscopy on the same day; the conventional examination allowed exploration of the entire colon. Conventional colonoscopy identified 89 lesions 3-50 mm in diameter, namely 84 benign and 5 malignant lesions. No lesions were identified in 12 patients. CT colonography identified 52 of the 89 lesions, with 57.1% diagnostic accuracy. They were 11 false positives (82.5% positive predictive value and 52.2% specificity) and 37 false negatives (24.5% negative predictive value and 58.4% sensitivity). Sensitivity was significantly higher (85.7%) for polyps ...

2000-06-01

427

Untersuchung von Bildqualitat und Genauigkeit der Dosisberechnung bei cone-beam-CT-Aufnahmen mit reduziertem Projektionsdatensatz (half scan, half fan) im Hinblick auf die Verwendbarkeit fur die adaptive Bestrahlungsplanung  

British Library Electronic Table of Contents (United Kingdom)

Subject of this study is the question of whether cone beam CT (CBCT) images with reduced projection data are suitable for use in adaptive radiation therapy (ART) treatment planning. For this purpose image quality and dose calculation accuracy depending on imaging modality were analysed. In this context, two CBCT-methods will be indicated having reduced projection data sets: Scans acquired with 200^o rotation angle in order to accelerate the CBCT process (half scan), or scans with an asymmetric cone beam and detector offset, used to enlarge the field-of-view (half fan). Methods: For three different CBCT-modes (On-Board-Imaging, Varian Medical Systems), two of them based on reduced projection data, and a conventional multidetector CT system, the main image quality parameters were studied. Tr...

2011-01-01

428

Scatter measurements for optical cone-beam computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Both x-ray and optical cone-beam CT (CBCT) scanners are limited by scattered photons that contaminate the primary images. Transparent radiochromic gels and plastics are anticipated to produce less scattering than polymerization gels and hence result in reconstructed dose distributions with greater contrast and dynamic range. Four methods of scatter measurement were investigated to quantify scatter fractions using an in-house optical CBCT scanner. The methods consisted of generating either 'coin' shadows or primary beamlets in transmission images. The four methods generated similar results of 10% scatter fractions in gel transmission images for this particular scanner configuration with both leuco crystal violet and carbon black micelle gels. The scatter contributions were distributed as 5% from micelle gel, 2% from Teflon wall, 2% from refractive index matching liquid and 1% other sources. Applying a uniform background subtraction of 2% of open ...

2009-05-01

429

Relationship between QRS transition zone and the interventricular septum; Using CT scan  

Energy Technology Data Exchange (ETDEWEB)

The relationship between the QRS transition zone of the standard 12-lead ECG and interventricular septum was studied. The position and the angle to the horizontal line of the interventricular septum were evaluated with computed tomography (CT) and compared to the QRS transition zone. The subjects were 36 patients with no cardiovascular diseases. The patients were divided into 3 groups according to the position of QRS transition zone: V{sub 1}-V{sub 2} (8 cases), V{sub 3}-V{sub 4} (21 cases), and V{sub 5}-V{sub 6} (7 cases). The interventricular septum on CT was directed to the anterior chest wall between V{sub 3} and V{sub 4} in all 3 groups. The mean value of the interventricular septal angle did not differ from group to group, 52.1deg for V{sub 1}-V{sub 2} group, 49.8deg for V{sub 3}-V{sub 4} group, and 48.2deg for V{sub 5}-V{sub 6}. It was concluded that the direction of the interventricular septum was not one of the major determinants of ...

1991-11-01

430

Recreating wetland ecosystems in an oil sands disturbed landscape : Suncor consolidated-tailings demonstration wetlands  

Energy Technology Data Exchange (ETDEWEB)

Open pit oil sands mining involves the disturbance of thin overburden covers of Boreal forest lands that must be returned to equivalent land capability after mining activities have ceased. Before mining starts, any wetlands are drained, timber is harvested, and peat, topsoils and subsoils are stockpiled for later use. This article discussed wetland reclamation activities conducted by Suncor Energy at its open pit mining operations. Research facilities were constructed in order to determine if wetlands constructed with consolidated tailings (CT) and pond effluent water (PEW) were able to support a sustainable vegetation community. Thirty-three cat-tail plots were established at the facility as well as unplanted plots in order to determine how quickly natural establishment occurred. Shoreline plug transplants and transplants from a natural saline lake were also introduced. Within 5 years, over 23 plant species had naturally colonized the CT ...

2009-10-01

431

Real-time cross-sectional averaged void fraction measurements in vertical annulus gas-liquid two-phase flow by neutron radiography and X-ray tomography techniques  

Energy Technology Data Exchange (ETDEWEB)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray CT technique. (orig.).

1995-03-11

432

Real-time cross-sectional averaged void fraction measurements in vertical annulus gas-liquid two-phase flow by neutron radiography and X-ray tomography techniques  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray CT technique. (orig.).

1995-03-01

433

Radiofrequency ablation of lung and liver lesions using CT fluoroscopy  

International Nuclear Information System (INIS)

Full text: Tumour ablation with radiofrequency (RF) energy is a relatively new procedure for the treatment of focal malignant disease. At our institution this is currently being used in the treatment of certain liver and lung lesions with the patients involved being enrolled in clinical trials. The poster describes the technique used at our institution for the placement of the radiofrequency ablation electrode using CT fluoroscopy. Criteria for patient selection are included. Complications from the procedure are described, as well as follow up appearances and results. Our results from the treatment of primary and secondary lesions in the liver correlate well with published literature. Treatment is still not as successful as surgical resection but there is significantly less morbidity. Where this method may be appropriate is when the patient is not a candidate for surgical resection. The treatment of colorectal metastases in the lung shows early promise as a ...

2002-06-01

434

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial pilot studies with ...

2008-06-01

435

Methodological study of hemodynamic analysis of lung mass by contrast enhanced dynamic CT  

Energy Technology Data Exchange (ETDEWEB)

We investigated a method of analyzing the hemodynamics of the lung mass by contrast enhanced dynamic computed tomography (dynamic CT) to determine the difference in vascular supply between the pulmonary artery and bronchial artery using an experimental model. Our experimental model consisted of two injectors connected to two tubes, representing the pulmonary artery and bronchial artery, which were further connected to a chamber representing the lung mass. Following infusion of contrast medium into each tube with some delay time, dynamic CT scans were performed to obtain time density curves of the two tubes and the chamber. Using the time-density curve of contrast passage, flow rates from the two tubes into the chamber were calculated by the curve fitting method. Calculated values correlated well with the adopted flow rates of fluid from the injectors (r=0.893) in the experiment. The results indicate our method of individually measuring flow ...

1996-06-01

436

Methodological study of hemodynamic analysis of lung mass by contrast enhanced dynamic CT  

International Nuclear Information System (INIS)

We investigated a method of analyzing the hemodynamics of the lung mass by contrast enhanced dynamic computed tomography (dynamic CT) to determine the difference in vascular supply between the pulmonary artery and bronchial artery using an experimental model. Our experimental model consisted of two injectors connected to two tubes, representing the pulmonary artery and bronchial artery, which were further connected to a chamber representing the lung mass. Following infusion of contrast medium into each tube with some delay time, dynamic CT scans were performed to obtain time density curves of the two tubes and the chamber. Using the time-density curve of contrast passage, flow rates from the two tubes into the chamber were calculated by the curve fitting method. Calculated values correlated well with the adopted flow rates of fluid from the injectors (r=0.893) in the experiment. The results indicate our method of individually measuring flow ...

437

Mesenchymal tumors of the pancreas. CT patterns; Tumori mesenchimali del pancreas: aspetti con tomografia computerizzata  

Energy Technology Data Exchange (ETDEWEB)

Purpose of this item is to report the CT patterns of pancreatic mesenchymal lesions and to investigate the capabilities and limitations of this technique in terms of characterization. In selected cases, CT can provide virtually diagnostic information (lipoma and teratoma), or at least highly suggestive findings (NHL, plexiform neurofibroma, lymphangioma). Moreover, knowledge of the variable morphostructural patterns of mesenchymal hisototypes (SCH, Sarcoma etc.) permits to include them in the differential diagnosis of pancreatic masses. [Italian] Scopo di questo rapporto e' descrivere gli aspetti semeiologici dei tumori mesenchimali del pancreas con la TC verificandone le possibilita e i limiti per la caratterizzazione. Pur nella rarita' dei reperti considerati, la TC puo' consentire l'effettiva caratterizzazione in alcuni casi (lipoma, neurofibroma plessiforme, linfangioma) o includere anche istotipi meno ...

1999-10-01

438

Magnetic resonance imaging in acute intractional tuberculosis; Magnetresonanztomographie bei akuter intrakranieller Tuberkulose  

Energy Technology Data Exchange (ETDEWEB)

We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.) [Deutsch] Die Befunde von drei Patienten mit intrakranieller Tuberkulose (intrakranielle Miliartuberkulose, Meningitis tuberculosa, Neuritis und Tuberkulome) in der Magnetresonanztomographie (MRT) wurden mit der Computertomographie (CT) verglichen. Sowohl die MRT als auch die CT wurden nativ und nach Kontrastmittelgabe durchgefuehrt. Die MRT zeigte sich im Nachweis von Granulomen insbesondere im Bereich des Hirnstamms ueberlegen. Ebenso wurde ein hoeherer ...

1994-12-31

439

MRT versus CT in the diagnosis of pneumonia. Evaluation of a T_2-weighted utrafast turbo-spin-echo sequence (UTSE)  

International Nuclear Information System (INIS)

Purpose: To evaluate a T_2-weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T_2-weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR_e_f_f/T_E/Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis and representation of the lesions, in 25% MRT was superior. MRT was better for the detection of pulmonary abscesses. In 93% the ...

1999-05-01

440

Iodixanol in cerebral computed tomography: a randomized, double-blind, phase-III, parallel study with iodixanol and iohexol  

International Nuclear Information System (INIS)

Iodixanol is a new nonionic dimer, isotonic with blood at all clinically relevant concentrations. Iodixanol (270 mg I/ml) was compared in a double-blind, randomized, parallel-group, phase-III study to the monomeric nonionic iohexol (300 mg I/ml) for evaluation of safety, tolerability and radiographic efficacy during cerebral CT. One hundred adult patients scheduled to undergo contrast-enhanced cerebral CT were randomly allocated to receive either iodixanol or iohexol. All completed the trial. Safety was evaluated by recording discomfort and other adverse events, tolerance by assessing intensity and incidence of discomfort. Radiographic efficacy was assessed from the diagnostic information and the radiographic density. No serious adverse events occurred. One patient (2 %) in the iodixanol group and one patient (2 %) in the iohexol group experienced a transient reddening at the neck and lower neck-line, respectively. Both contrast agents were ...

1999-09-01

441

Intrapartum FHR monitoring and neonatal CT brain scan  

Energy Technology Data Exchange (ETDEWEB)

The effect of fetal distress on the neonatal brain was investigated by neonatal CT brain scan, FHR monitoring and mode of delivery. This study involved 11 cases of full term vertex delivery in which FHR was recorded by fetal direct ECG during the second stage labor. All infants weighed 2,500 g or more. FHR monitoring was evaluated by Hon's classification. Neonatal brain edema was evaluated by cranial CT histgraphic analysis (Nakada's method). 1) Subdural hemorrhage was noted in 6 of 7 infants delivered by vacuum extraction or fundal pressure (Kristeller's method). 2) Intracranial hemorrhage was demonstrated in all of 3 infants with 5-min. Apgar score 7 or less. 3) Two cases with prolonged bradycardia and no variability had intraventricular or intracerebral hemorrhage which resulted in severe central nervous system damage. 4) The degree of neonatal brain edema correlated with 5-min. Apgar score. 5) One case with ...

1982-12-01

442

Intrapartum FHR monitoring and neonatal CT brain scan  

International Nuclear Information System (INIS)

The effect of fetal distress on the neonatal brain was investigated by neonatal CT brain scan, FHR monitoring and mode of delivery. This study involved 11 cases of full term vertex delivery in which FHR was recorded by fetal direct ECG during the second stage labor. All infants weighed 2,500 g or more. FHR monitoring was evaluated by Hon's classification. Neonatal brain edema was evaluated by cranial CT histgraphic analysis (Nakada's method). 1) Subdural hemorrhage was noted in 6 of 7 infants delivered by vacuum extraction or fundal pressure (Kristeller's method). 2) Intracranial hemorrhage was demonstrated in all of 3 infants with 5-min. Apgar score 7 or less. 3) Two cases with prolonged bradycardia and no variability had intraventricular or intracerebral hemorrhage which resulted in severe central nervous system damage. 4) The degree of neonatal brain edema correlated with 5-min. Apgar score. 5) One case with prolonged bradycardia and no ...

1982-01-01

443

Evolution of virtual CT laparoscopy for preoperative imaging in laparoscopic cholecystectomy  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to determine the feasibility of virtual endoscopy, named as ''virtual CT laparoscopy'', in the hepatobiliary system prior to laparoscopic cholecystectomy. We applied this technique to 28 patients suspected of having biliary disease. These images were compared and analyzed qualitatively based on visualization of the structures critical to operative cholangiography and surgical findings. Twenty-four patients, who underwent laparoscopic cholecystectomy, were evaluated as follows: the common bile duct and the hepatic duct were adequately visualized in 23 (96%) of the 24 patients, the cystic duct in 21 (88%), the gallbladder opacification in 20 (83%), the liver inferior surface in 20 (83%). Four patients had anatomic variations detected virtual CT laparoscopy and were proven by operative cholangiography and surgical findings. We emphasize that our new technique may contribute to the ...

2002-06-01

444

Evaluation of selective alveolo-bronchography with Fuji computed radiography and x-ray CT  

International Nuclear Information System (INIS)

Selective alveolo-bronchography (SAB) has been routinely used to evaluate anatomical changes in the bronchiole and its distal air spaces. A narrowing of the bronchiole and abnormal pooling of contrast medium in the destroyed air space are the prime findings. Since the object of radiography is extremely thin, direct magnification radiography is mandatory to obtain radiologic details. However, the problem with this technique is that radiographic quality varies depending upon the size of the patient and the concentration of contrast medium to be introduced in the lung. This study had two goals. One was to improve the image quality of SAB by Fuji Computed Radiography (FCR). FCR provides radiographs with a good contrast and stable density throughout a wide range of exposure factors which occur in the use of SAB. The other goal was to separately evaluate morphological abnormalities in the outer and inner zones of the lung using X-ray CT. This idea was derived from our ...

1986-01-01

445

Dosimetry in dental radiology. Dentascan spiral CT versus panoramic radiography; Dosimetria nella radiologia odontostomatologica: confronto tra tomografia computerizzata spirale e ortopantomografia  

Energy Technology Data Exchange (ETDEWEB)

The study compares the doses absorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations. [Italian] Questo lavoro intende confrontare le dosi assorbite nel distretto dento-mascellare, con le due principali tecniche utilizzate in questo campo: TC spirale e ortopantomografia. Emerge come l'esame panoramico delle arcate dentarie eseguito con l'ortopantomografo comporti la'ssorbimento di dosi inferiori rispetto a quelle dell'esame TC spirale con programma Dentascan. Questi dati, pur essendo soggetti a ...

1999-05-01

446

Diagnostic features of intrahepatic cholangiocarcinoma according to the gross type classification  

International Nuclear Information System (INIS)

Forty resected cases of intrahepatic cholangiocarcinoma were classified into four types according to the gross appearance; type I: mass forming type (n=8), type II: mass forming with periductal infiltrating type (n=20), type III: periductal infiltrating type (n=9) and type IV: intraductal growth type (n=3). Diagnostic features of these four types were studied. Peripheral enhancement was a common angiographic feature and tumor stains were recognized in 88%, 20%, 0%, 33%, respectively. Angiography and dynamic computed tomography (D-CT) were useful in differential diagnosis with hepatocellular carcinoma. Accuracy rate in diagnosis of portal vein involvement by angiography and D-CT was 82% and 91%, respectively. MRI was more useful in tumor detection than D-CT in cases with attenuation difference, in 55% of type II and in 75% of type III. Increase of arterial involvement, biliary tract involvement and portal vein involvement, ...

1998-08-01

447

Computed tomography of the thorax: a status report  

Energy Technology Data Exchange (ETDEWEB)

Computed tomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computed tomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. Future applications of CT include the ...

1981-11-01

448

Computed tomography of the thorax: a status report  

International Nuclear Information System (INIS)

Computed tomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computed tomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. Future applications of CT include the ...

449

Computed tomography of the chest in the postoperative recurrences of bronchogenic carcinoma  

International Nuclear Information System (INIS)

The authors describe the different types of postoperative carcinoma recurrences, as seen on CT examinations of the chest, in 38 patients who underwent different surgical procedures for bronchogenic carcinoma (12 pneumonectomies, 22 lobectomies, 2 segmentectomies, and 2 atypical resections). The recurrences were classified as follows: 1) recurrence in the bronchial stump; 2) limph node enlargement; 3) recurrence in the thoracic wall; 4) recurrence in the residual lobe; 5) pleural effusion; 6) nodule in the contralateral lung. The CT findings, Correlated with those from plain chest radiographs and clinical simptoms, indicate a higher incidence of recurrences in the hilar region, either in the bronchial stump or as node after total and subtotal resection are separately analyzed. While after pneumonectomy plain chest radiographs fail to demonstrate the recurrence in most cases, so that CT is nearly always mandatory, after ...

1990-01-01

450

Cholangiocarcinoma associated with recurrent pyogenic cholangitis: sonographic and CT findings  

International Nuclear Information System (INIS)

Cholangiocarcinoma may be associated with recurrent pyogenic cholangitis as a complication of longstanding proliferative cholangitis in the presence of intrahepatic stones. Sonographic and CT findings of six patients with cholangiocarcinoma of the liver associated with recurrent pyogenic cholangitis are presented. The cases were among 128 patients who underwent partial resection of the liver because of recurrent pyogenic cholangitis and its complication. On sonogram the mass was depicted in four patients as an ill-defined heterogenously echogenic mass and in one patient as a bulging contour; in the remaining one case the mass was not detected. There were small or large, shadowing or non shadowing stones within the tumor in five cases. In one case, the stone was in the duct proximal to the tumor. On CT scans of four patients, the tumors were depicted as an ill-defined, irregular low attenuation masses with variable contrast enhancement, the ...

1992-01-01

451

CT-guided percutaneous core biopsies of pulmonary lesions: Diagnostic accuracy, complications and therapeutic impact  

International Nuclear Information System (INIS)

To evaluate the diagnostic accuracy, complications, and therapeutic impact of CT-guided percutaneous core biopsies of pulmonary lesions. Material and methods: Seventy-nine patients underwent diagnostic CT-guided percutaneous core biopsies of pulmonary lesions between July 1995 and March 1999. Evaluation included corresponding clinical data, pathologic results, and therapeutic consequences. Results: There were 29 benign and 50 malignant lesions. Percutaneous core biopsy had an overall diagnostic accuracy of 95%. For malignant lesions, core biopsy was positive in 48 patients (sensitivity 96%), and for benign lesions, in 27 (sensitivity 93%). There were no false-positive findings. Pneumothoraces were observed in 19 patients (24%) and 4 of them required a chest drain (5%). There were no hematothoraces or major bleeding complications; however, postinterventional local hemorrhages were observed in 23 patients (29%). No hemoptysis was noted. ...

2001-03-01

452

CT diagnosis of subphrenic abscess after splenectomy for trauma; Ruolo della tomografia computerizzata nella valutazione degli ascessi subfrenici dopo splenectomia post-traumatica  

Energy Technology Data Exchange (ETDEWEB)

The paper studies subphrenic inflammatory abscesses and splenic fluid collections after splenectomy for trauma. These complications may appear early or late postoperatively; they are easily demonstrated with computerized tomography, which permits accurate spatial assessment of the lesions and appropriate treatment with percutaneous drainage. It has been also investigates the diagnostic accuracy of the CT in subphrenic inflammatory conditions after emergency splenectomy for traumatic spleen rupture and found that CT is a precious tool for rapid and easy diagnosis and follow-up of subphrenic abscesses treated with percutaneous drainage. [Italian] Scopo del lavoro e' di valutare il ruolo della tomografia computerizzata nelle flogrosi subfreniche secondarie a splenectomia d'urgenza per rottura traumatica della milza, documentando come tale metodica risulti accurata nel diagnosticare e monitorare in modo semplice e rapido ...

1999-09-01

453

Benign and malign pulmonary tumors in childhood; Benigne und maligne Lungentumoren im Kindesalter  

Energy Technology Data Exchange (ETDEWEB)

Pulmonary tumors in children are rare. Nevertheless, there are besides malign primary neoplasms and metastases also some benign tumors that the radiologist should know. The identification of some tumors is difficult, since some of them may mimic pulmonary inflammation. The first diagnostic tool is chest radiography. After that, a CT with contrastmedium should be performed, if possible a multislice-CT (MSCT). Identification of mediastinal structures is best with MRI. (orig.) [German] Tumoren der Lunge sind im Kindesalter selten. Trotzdem finden sich neben den malignen primaeren und sekundaeren Raumforderungen auch im Kindesalter immer wieder benigne Tumoren, die der Radiologe kennen sollte. Eine eindeutige Identifizierung kann schwierig sein, da z. B. entzuendliche Infiltrate vorgetaeuscht werden koennen. Die primaere Untersuchungsmethode ist das konventionelle Thoraxroentgen. Die weitere Diagnostik muss mit der Computertomographie, nach ...

2003-12-01

454

A new application of MRT of the lung using ultra-shot turbo spin echo sequences (UTSE)  

International Nuclear Information System (INIS)

T_2 weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T_E=90 ms, T_R=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good quality. Compared with CT, contrast is better with MRT, offering diagnostic ...

455

A look ahead: PET/MR versus PET/CT  

Energy Technology Data Exchange (ETDEWEB)

Integration of positron emission tomography (PET) and magnetic resonance (MR) has become a topic of increasing interest to the imaging community over the past two years. In this text, the authors attempt to distinguish facts from fiction concerning such integrated systems. Analysis of existing information of combined imaging on existing brain PET/MR systems and imaging experience with PET-computed tomography (CT) is reviewed. Various types of system integration of PET and MR are discussed with completely independent systems on one hand and completely integrated systems with the possibility of simultaneous data acquisition on the other hand. Furthermore, it is discussed, what simultaneous data acquisition with nuclear imaging systems combined with MR or CT really means, as technical simultaneity may not be relevant in light of the pharmacokinetics of the nuclear tracers used. The authors conclude that combining PET/MR is an interesting research ...

2009-03-15

456

Excessive copper concentrations in the tap water of households with copper pipes and an assessment of possible health hazards for infants. First results of a study; Gesundheitliche Gefaehrdung ungestillter Saeuglinge durch Kupfer in Haushalten mit kupfernen Trinkwasserleitungen. Erste Ergebnisse einer prospektiven Studie  

Energy Technology Data Exchange (ETDEWEB)

To determined precisely a possible connection between the amount of copper in tap-water and the risk of early childhood liver disease, it was attempted through an epidemiological survey, to determine the extent of excessive concentrations of copper in the tap-water of households with copper pipes. Water samples from 956 households were tested for copper, and the state of health of the infants in these households was documented. Infants who had been fed using water with a copper concentration of 0.8 mg/l or more received a paediatric examination with a blood serum analysis to rule out any liver damage. A copper level greater than 0.8 mg/l was found in only 2% of the households examined. Eight infants were examined by a paediatrician and their serum was analysed. These infants had either been breast-fed to the 12th week or had received more than 200 ml of tap water per day during first 12 months. None of the infants examined showed any signs of liver malfunction. ...

2000-04-01

457

Radiological diagnosis of lesions of intervertebral discs; Radiologische Diagnostik von Bandscheibenlaesionen  

Energy Technology Data Exchange (ETDEWEB)

During their life, intervertebral discs undergo degenerative changes which need not necessarily become lesions. Conventional X-rays do not provide information on the condition of the intervertebral discs, so MRT or CT are recommended as primary techniques as they are non-invasive. Invasive methods like myelography and especially discography should not be used unless a case is highly problematic. In infants with pains in the back, MRT should be carried out as early as possible as there is nearly always an organic cause. (orig.) [German] Die Bandscheibe ist im Laufe des Lebens degenerativen Veraenderungen unterworfen, die klinisch zu Beschwerden fuehren koennen, aber nicht fuehren muessen. Konventionlle Roentgenaufnahmen lassen zwar die Hoehenminderung des Bandscheibenfachs und begleitende knoecherne Veraenderungen erkennen, nicht aber den Zustand der Bandscheibe selbst. Die Beurteilung der Bandscheibe und des Knochens gelingt mit der CT, die ...

2003-03-01

458

Clinically silent heterotaxy with polysplenia syndrome and IVC azygous continuation draining to SVC: CT findings. Case report  

International Nuclear Information System (INIS)

Patients with heterotaxy syndrome often have complex cardiac and extracardiac anomalies requiring further detailed diagnostic evaluation. They often present severe cardiac failure early in life. Newer radiological modalities in the form of spiral computed tomography (CT) and three-dimensional reconstruction of spiral CT allow clear definition of the anatomy of these anomalies. A 59-year-old woman was diagnosed with polysplenia and multiple anomalies in an abdominal ultrasonography (US) during a control medical examination due to a trivial dietary mistake. She was then referred to our institution for further examination of these anomalies and an additional thoraco-abdominal computed tomography (CT) examination. The patient was totally asymptomatic at the time of admission. There was no significant past history and no abnormal laboratory data. We performed abdominal, pelvic and thoracic CT examinations ...

2007-01-01

459

A new application of MRT of the lung using ultra-shot turbo spin echo sequences (UTSE); Ein neuer Ansatz in der Magnetresonanztomographie der Lunge mit einer ultrakurzen Turbo-Spin-Echo-Sequenz (UTSE)  

Energy Technology Data Exchange (ETDEWEB)

T{sub 2} weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T{sub E}=90 ms, T{sub R}=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good quality. Compared with CT, contrast is better with MRT, offering ...

1996-05-01

460

Sonography, Computed Tomography and ERCP in the diagnosis of focal exocrine pancreatic disease  

International Nuclear Information System (INIS)

In spite of the improved imaging techniques currently available, mortality for pancreatic cancer is still high, and pancreatics is often diagnosed only in its advanced stages. The authors investigated the value of different imaging techniques - i.e., US, CT, and ERCP - for an early diagnosis, when a more effective (curative?) treatment can be suggested. Fifty-six cases of pancreatic cancer and 36 cases of chronic pancreatitis were evaluated. The results indicate that ERCP, with the help of statistical methods, is superior to US and CT not only in evaluating early neoplastic or inflammatory lesions, but also for their differential diagnosis. In the letter case, ERCP can sometimes be used as a valid alternative to fine-needle aspiration biopsy.

1991-01-01

461

Sialography, echography and computed tomography in parotid gland study  

International Nuclear Information System (INIS)

The diagnostic accuracy of sialography and ultrasonography (US) in the evaluation of parotid masses is evaluated. Furthermore the role of computed tomography (CT) in this pathology is discussed. In the personal experience US proved to be the best method in the recognition of a parotid tumor while sialography was superior in defining the intra or extraparotid site. The two investigations showed the same accuracy in the definition of benign or malignant nature of the mass. Therefore we consider US the only investigation in most istances; sialography could be performed when the site of the lesion is uncertain or an inflammatory lesion is suspected. CT is never the first investigation; its use is limited to a low number of cases, mainly for the evaluation of large masses and when the association US-sialography does not allow a sure diagnosis.

1985-01-01

462

Retroperitoneoscopic partial adrenalectomy for small adrenal tumours (<=1 cm): the Ruijin clinical experience in 88 patients  

British Library Electronic Table of Contents (United Kingdom)

Study Type - Therapy (case series)Level of Evidence 4 OBJECTIVE To present our experience of retroperitoneoscopic partial adrenalectomy (RPA) for small adrenal tumours, as with modern imaging methods small adrenal lesions are being diagnosed more commonly, and retroperitoneoscopic adrenal surgery for small adrenal tumours (PATIENTS AND METHODS We retrospectively reviewed the records of 389 consecutive retroperitoneoscopic adrenalectomies from September 2005 to December 2008, 88 of which were small adrenal tumours and treated by RPA. Ultrasonography and computed tomography (CT) were used in all patients before RPA, and magnetic resonance imaging or positron emission tomography/CT in some patients. We used RPA for adrenal tumours and total adrenalectomy for adrenal cancer. During the surgery...

2010-01-01

463

Radioexposure of children in cranial examinations with new-generation CT equipment  

Energy Technology Data Exchange (ETDEWEB)

Using phantoms of children simulating a child of 6 months of age and another one aged 6 years, the authors measured the amount of radioexposure of the lens of the eye, the thyroid and of the gonads. The two computer tomographs Somatom SF and Tomoscan 300 under examination, produced radiodoses of comparable magnitudes. Both devices allow additional examination techniques of particularly high economy. It was found that in cranial CT the exposure of the lens to radiation is generally below 1 R if the orbitae are not situated in the plane of section. If a distance of 2-3 cm is maintained from the orbitae, the dose remains below 0.5 R. Protecting the gonads is meaningful in a 6-year-old boy, whereas covering-up of the thyroid reduced the dose only slightly.

1983-04-01

464

Preoperative image diagnosis of hypertrophied parathyroid glands in patients with renal osteodystrophy  

International Nuclear Information System (INIS)

Computed tomography (CT) of the neck and mediastinum was performed in 16 patients with renal osteodystrophy. Thirty out of 34 excised parathyroid glands weighing more than 500mg were diagnosed preoperatively (88.2%). Scintigraphy of the neck with _2_0_1TlCl and sup(99m)TcOsub(4-) was also performed in 15 patients. The introduction of subtraction method with a mini-computor in the scintigraphy has remarkably improved the visualization rate of parathyroid glands. Ultrasonic echography (US) of the neck which is able to obtain not only transverse butalso longitudinal imaging was done in 7 patients. It has about same detection rate of the glands with CT. The visualization of enlarged parathyroid glands is valuable not only for localization but also for undeniable evidence of hyperparathyroidism. Also, repeated follow-up examination can determine the effectiveness of conservative treatment. (author).

465

Malignant solitary fibrous tumor of the thyroid gland: Report of a case and review of the literature  

British Library Electronic Table of Contents (United Kingdom)

Abstract Solitary fibrous tumors of the thyroid gland (T-SFT) are rarely described, with only 21 cases being reported in the English literatures, all showing benign clinical characteristics. We herein present a 76-year-old woman presenting with a 3-month history of rapidly enlarging neck masses and the CT showed masses with partial calcification in the right thyroid lobe. We performed right hemithyroidectomy and isthmectomy with negative margin under general anesthesia. Histologically, the masses consisted of pleomorphic spindle cells with high mitoses and collagen bands. Immunohistochemically, the tumor cells showed positive reactions for CD34, vimentin and bcl-2, then a diagnosis of malignant solitary fibrous tumor of the right thyroid was made. Six months postoperatively, the CT showed ...

2011-01-01

466

Image diagnosis of parathyroid glands in chronic renal failure  

Energy Technology Data Exchange (ETDEWEB)

Twenty-two out of 31 patients with chronic renal failure and secondary hyperparathyroidism who underwent parathyroidectomy before operation underwent non-invasive image diagnosis of parathyroid glands by computed tomography (CT), scintigraphy with /sup 201/TlCl and /sup 99m/TcO/sup 4 +/, and/or ultrasonography. CT visualized 39 of 45 parathyroid glands (86.7%), weighing more than 500 mg. Scintigraphy with a subtraction method using a computer performed the diagnosis in 19 of 27 glands (70.4%). Ultrasonography detected 21 of 27 glands (77.8%). Image diagnosis was also useful in the postoperative follow-up study. The non-invasive image diagnosis of parathyroid glands in patients with chronic renal failure is thus valuable for 1) definite diagnosis of secondary hyperparathyroidism, 2) localization, and 3) diagnosis for effectiveness of conservative treatment.

1983-07-01

467

Evaluation of node involvement in non small cell bronchogenic carcinoma. CT-pathology correlation  

International Nuclear Information System (INIS)

The main purpose of this work is to evaluate the role of CT in identifying other morphological signs of met static lymph node involvement from non small cell bronchogenic carcinoma. This is done to improve N staging, a critical step in this disease. In fact, since diameter is the only criterion used to distinguish normal form abnormal lymph nodes, mediastinal CT only has 80% diagnostic accuracy. 137 patients with known or suspected lung cancer were examined with Helical CT during early and late arterial phases (2 min. delay, 3 mm thickness, 5 mm inter slice gap) to depict node characteristics. Mediastinal lymph nodes, located according to the American Thoracic Society mapping, were considered normal when they were not visible or, if visible, less than 1 cm in diameter and of homogeneous density; lymph nodes over 1 cm in diameter and homogenous density were considered reactive. A lymph node was considered metastatic when, ...

2000-05-01

468

Early-stage focal nodular hyperplasia: US/CT/MR features correlated with histology  

Energy Technology Data Exchange (ETDEWEB)

Two cases of focal nodular hyperplasia (FNH), in which ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MR) studies detected an atypical hemorrhagic pattern associated with an intrahepatic arterio venous malformation (AVM) around the growths, are presented. In both cases, histology demonstrated a very early regenerative stage and necrotic-hemorrhagic areas within the lesions. In these cases, the analysis of radiological findings, surgical specimens and histology seemed to confirm the pathogenetic hypothesis suggested by Wanless: in normal liver parenchyma, a ``blood steal`` phenomenon due to congenital or acquired intrahepatic AVM could cause ischemic damage, appearing as a hemorrhagic necrotic area, the extent of which depends on the degree of residual portal supply. (orig.)

1994-02-01

469

Contrast material extravasation following upper abdominal trauma. Detection with helical Computerized Tomography  

International Nuclear Information System (INIS)

Active contrast material extravasation can be recognized with conventional CT scanners, though it has been considered a rare finding. Helical CT seems to increase the detection rate and especially to boost the radiologist's confidence in this diagnosis. Though active bleeding is defined in severely-injured subjects requiring urgent intervention and may be associated with findings of hypovolaemic shock, it should not be considered itself as a negative prognostic factor. Contrast extravasation is due to ongoing hemorrhage and its detection is critical for urged treatment. Accurate anatomical location permits to choose surgical management or transcatheter embolization and thus decreases time consumption for precis e bleeding site identification.

1999-03-01

470

Computational mouse atlases and their application to automatic assessment of craniofacial dysmorphology caused by the Crouzon mutation Fgfr2C342Y  

British Library Electronic Table of Contents (United Kingdom)

Abstract Crouzon syndrome is characterized by premature fusion of sutures and synchondroses. Recently, the first mouse model of the syndrome was generated, having the mutation Cys342Tyr in Fgfr2c, equivalent to the most common human Crouzon/Pfeiffer syndrome mutation. In this study, a set of micro-computed tomography (CT) scannings of the skulls of wild-type mice and Crouzon mice were analysed with respect to the dysmorphology caused by Crouzon syndrome. A computational craniofacial atlas was built automatically from the set of wild-type mouse micro-CT volumes using (1) affine and (2) non-rigid image registration. Subsequently, the atlas was deformed to match each subject from the two groups of mice. The accuracy of these registrations was measured by a comparison of manually placed landma...

2007-01-01

471

Brain tumors in children and teenagers up to 18 in CT; Nowotwory mozgowia u dzieci i mlodziezy do 18. roku zycia rozpoznane w tomografii komputerowej  

Energy Technology Data Exchange (ETDEWEB)

The results of the CT investigation in children and teenagers up to 18, made in 1990-1994 were exposed to retrospective analysis: 2279 children were examined. The computer research proved the pathological changes in case 1205 people - 52%. In this group 58 children turned out to suffer from brain tumors. The most frequent tumor spatted was: astrocytoma (8), ependymoma (5), oligodendroglioma (3). The brain tumors happen to appear more often in case of boys (34) than in case of girls (22). (author) 6 refs, 2 figs, 2 tabs

1995-12-31

472

Usefulness of "1"8F-FDG PET in intrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Surgical resection is the only curative treatment strategy for intrahepatic cholangiocarcinoma (CC). Therefore, accurate staging is essential for appropriate management of patients with CC. We assessed the usefulness of 2-["1"8F]fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) in the staging of CC. We undertook a retrospective review of FDG PET images in 21 patients (10 female, 11 male; mean age 57 years) diagnosed with CC. Ten patients had hilar CC and 11, peripheral CC. Patients underwent abdominal magnetic resonance imaging (MRI) (n=20) and computed tomography (CT) (n=12) for the evaluation of primary tumours, and chest radiography and whole-body bone scintigraphy for work-up of distant metastases. For semi-quantitative analysis, the maximum voxel standardised uptake value (SUV_m_a_x) was obtained from the primary tumour. All peripheral CCs showed intensely increased FDG uptake, and some demonstrated ring-shaped uptake corresponding to ...

2003-11-01

473

Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques  

International Nuclear Information System (INIS)

Positron emission tomography (PET) is a fully quantitative technology for imaging metabolic pathways and dynamic processes in vivo. Attenuation correction of raw PET data is a prerequisite for quantification and is typically based on separate transmission measurements. In PET/CT attenuation correction, however, is performed routinely based on the available CT transmission data. Recently, combined PET/magnetic resonance (MR) has been proposed as a viable alternative to PET/CT. Current concepts of PET/MRI do not include CT-like transmission sources and, therefore, alternative methods of PET attenuation correction must be found. This article reviews existing approaches to MR-based attenuation correction (MR-AC). Most groups have proposed MR-AC algorithms for brain PET studies and more recently also for torso PET/MR imaging. Most MR-AC strategies require the use of complementary MR and transmission images, ...

2009-03-01

474

The Growth of an Extrapancreatic Solid Pseudopapillary Tumor from the Greater Omentum: A Case Report  

Energy Technology Data Exchange (ETDEWEB)

A solid pseudopapillary tumor is an uncommon tumor of the pancreas that rarely metastasizes to other organs and usually shows good prognosis. An extrapancreatic tumor arising from a solid pseudopapillary tumor is very rare. We report a case of an atypical extrapancreatic solid pseudopapillary tumor that arose from the great omentum and disseminated to the peritoneum, and discuss the radiologic findings, including the CT, US, and MRI.

2010-01-15

475

The Growth of an Extrapancreatic Solid Pseudopapillary Tumor from the Greater Omentum: A Case Report  

International Nuclear Information System (INIS)

A solid pseudopapillary tumor is an uncommon tumor of the pancreas that rarely metastasizes to other organs and usually shows good prognosis. An extrapancreatic tumor arising from a solid pseudopapillary tumor is very rare. We report a case of an atypical extrapancreatic solid pseudopapillary tumor that arose from the great omentum and disseminated to the peritoneum, and discuss the radiologic findings, including the CT, US, and MRI

2010-01-01

476

The DNA and RNA specificity of eilatin Ru(II) complexes as compared to eilatin and ethidium bromide  

UK PubMed Central (United Kingdom)

Eilatin-containing ruthenium complexes bind to a broad range of different nucleic acids including: calf thymus (CT) DNA, tRNAPhe, polymeric RNAs and DNAs, and viral RNAs including the HIV-1...Full Text Available

2003-10-01

477

Rational imaging strategies in larynx disease; Rationelle bildgebende Strategien bei Kehlkopferkrankungen  

Energy Technology Data Exchange (ETDEWEB)

Clinical information is indispensable for swift and cost-effective clarification of diseases of the larynx. While quality clarification of neurological changes in the area of the posterior cranial fossa and in the course of the vagus nerve as a cause of glottis malfunction is possible with MRI, localized disease of the larynx can more effectively be assessed with low-artifact CT. In the particularly difficult assessment of the post-operative larynx, a recurrence can be diagnosed only after a baseline study has been carried out after the end of therapy. With knowledge of the pretherapeutic findings, the findings immediately post-therapy, and the operation technique used, the optimal CT examination, which can be carried out quickly, will be able to provide more information about recurrence. (orig.) [Deutsch] Zur schnellen und kostenguenstigen Abklaerung von Erkrankungen des Larynx ist die klinische Information unabdingbar: Wenn neurologische ...

1998-02-01

478

Radiological diagnosis of lesions of intervertebral discs  

International Nuclear Information System (INIS)

During their life, intervertebral discs undergo degenerative changes which need not necessarily become lesions. Conventional X-rays do not provide information on the condition of the intervertebral discs, so MRT or CT are recommended as primary techniques as they are non-invasive. Invasive methods like myelography and especially discography should not be used unless a case is highly problematic. In infants with pains in the back, MRT should be carried out as early as possible as there is nearly always an organic cause. (orig.)

2003-03-01

479

Radiologic findings of extraosseous Ewing's sarcoma  

International Nuclear Information System (INIS)

The purpose of this study is to evaluate the radiologic findings of the extraosseous Ewing's sarcoma. Six patients with pathologically confirmed extraosseous Ewing's sarcoma were retrospectively reviewed. Patients included two men and four women with an average age of 21.5 years (age range 9-48 years). Plain radiographs (six patients), magnetic resonance (MR) images (five patients), computed tomographic (CT) scans (three patients) and whole body scintigraphy (two patients) were reviewed and analyzed. Images were evaluated with regard to lesion location, size, margin, muscle or bone involvement and intrinsic imaging characteristics on CT and MRI. The tumors were located in the thigh (three patients), back (two patients) and upper arm (one patient). The tumors ranged in size from 2.3 cm to 7.5 cm (mean, 5.2 cm), were mainly well circumscribed and showed no evidence of calcification prior to treatment. Margins were well defined in four out of the ...

2005-09-01

480

Peripheral cholangiocarcinoma : three-phase helical CT appearance  

International Nuclear Information System (INIS)

To analyze the enhancement patterns and morphology of peripheral cholangiocar-cinomas (CCs), as seen on three-phase helical CT. Three-phase helical CT scans of 25 cases of 24 patients with pathologically-proven CCs were retrospectively reviewed. After intravenous administration of contrast media, scans of the hepatic arterial phase (HAP) were obtained at 30 seconds, of the portal venous phase (PVP) at 70 seconds, and of the delayed phase (DP) at 3 minutes. Linear, dense, marginal enhancement was seen in 17 CCs (68%), mainly on HAP images (64%) while thick, band-like, peripheral enhancement was seen in 18 (72%), on either PVP (52%) or DP (44%). Internal enhancement was observed in 23 CCs (92%) on PVP (68%) and/or DP (88%), and 19 CCs (76%) among them showed incomplete enhancement of stippled and/or septated patterns. Most (76%) were seen throughout all three phases to be hypoattenuating, as compared to the surrounding parenchyma. On HAP, ...

1997-08-01

481

Patterns of vascular invasion of intrahepatic peripheral cholangiocarcinoma examined with angiography and angiographic CT  

International Nuclear Information System (INIS)

To evaluate the radiological patterns of vascular invasion in peripheral cholangiocarcinomas. Hepatic arteriography and portography in 20 cases with cholangiocarcinoma including 12 cases with angiographic CT were retrospectively analyzed. The arteriography showed no arterioportal shunt, hypertrophy of tumor vessel, or tumor staining extending to central portion of the mass in all cases. However, doughnut shaped peripheral tumor staining was seen until late hepatogram phase in 12 cases and compensatory hyperperfusion around the mass was seen in six cases (eight cases if include arterial CT). Encasement of tumor vessel was seen in 12 cases, and hypertrophy of feeding vessel in nine cases. On portography, the filling defect on segmental portal branch could be demonstrated only in 11 cases. Shape of the portal defect was tapered narrowing in six cases, abrupt narrowing in two cases but intraluminal nodular filling defect was not seen. Remaining ...

1995-01-01

482

Optimizing bowel preparation for multidetector row CT colonography: Effect of Citramag and Picolax  

Energy Technology Data Exchange (ETDEWEB)

AIM: To compare the adequacy and acceptability of Picolax and Citramag bowel cleansing agents for CT colonography. MATERIALS AND METHODS: Multidetector row CT colonography was performed in 124 subjects; 43 had been prepared with Picolax and 81 with Citramag. Datasets were assessed for retained fluid and solid residue, and overall adequacy of segmental visualization. Preparation acceptability was also assessed. RESULTS: There was significantly less retained fluid with Picolax. The odds of being in the next higher category for retained fluid when using Picolax were 0.33 (CI: 0.22-0.50, p<0.0001) when compared with Citramag, for all segments combined. However there was significantly more retained solid residue with Picolax. The odds of being in the next higher category for retained residue when using Picolax were 2.44 (CI: 1.41-4.24, p=0.002) when compared with Citramag, for all segments combined. There was no significant difference with ...

2003-09-01

483

Multislice spiral CT (MSCT) in pediatric radiology: dose reduction for chest and abdomen examinations  

International Nuclear Information System (INIS)

The advent of multislice spiral CT (MSCT) technique has led to new aspects of dose reduction, especially for the dedicated use of MSCT in children. Optimizing pediatric MSCT protocols according to the clinical problem allows reduction of radiation exposure to a minimum without loss of diagnostic quality. The different parameters that influence the degree of dose reduction, like tube current-time product (mAs), tube voltage (kV), collimation and pitch, are discussed in context with previously published data and our own experience in nearly 200 pediatric CT examinations. In our department, the effective mAs is calculated for a pediatric chest MSCT by multiplication of the body weight in kilogram with a factor of 1 to 1.5 and for a pediatric abdominal MSCT by multiplication with a factor of 2 to 2.5. To calculate the equivalent effective dose for a contrast media-enhanced 80 kV protocol, the effective mAs of the 120 kV protocol can be multiplied ...

2004-07-01

484

Multislice helical CT in the diagnosis of hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Objective: To investigate the value ofMSCT in observing the direct findings of hilar cholangiocarcinoma1Methods Multislice helical CT studies were performed on the upper abdomen in 19 consecutive patientswith painless jaundice1 Precontrast and dynamic contrast enhanced (25 s phase and 60 s phase) scanswere conducted, and 3D imageswere reconstructed using enhanced raw data in 15 cases1 The direct CT findings of hilar cholangiocarcinoma were studied by three radiologists respectively in a 32scale strategy1 The morphological features and extension of bile duct involvement by hilar cholangiocarcinoma were analyzed1 All the 19 caseswere pathologically p roved as hilar cholangiocarcinoma by surgery (15 cases) and ERCP ( 4 cases) 1 Results The direct findings and extension of hilar cholangiocarcinoma could be demonstrated in 14 out of 15 3D reconstruction images, 8 out of 19 in 25 s phase, and 7 out of 19 in 60 s phase of contrast enhancement scans, ...

2005-11-01

485

Moxel: A molar tooth voxel model for dosimetric studies  

Energy Technology Data Exchange (ETDEWEB)

Stylized numerical models of the tooth are usually employed in qualification procedure related to Electronic Paramagnetic Resonance in long-term accidental contamination dose reconstruction. In this work a voxel model was developed from the microCT image data set of a human non contaminated molar tooth. A stylized model, reproducing the characteristics of the voxel model, was also created in order to investigate the level of accuracy that can be obtained in this kind of study.

2010-02-15

486

Micro borehole drilling platform  

Energy Technology Data Exchange (ETDEWEB)

This study by CTES, L.C. meets two main objectives. First, evaluate the feasibility of using coiled tubing (CT) to drill 1.0 inches-2.5 inches diameter directional holes in hard rocks. Second, develop a conceptual design for a micro borehole drilling platform (MBDP) meeting specific size, weight, and performance requirements. The Statement of Work (SOW) in Appendix A contains detailed specifications for the feasibility study and conceptual design.

1996-10-01

487

Magnetic resonance imaging in acute intractional tuberculosis  

International Nuclear Information System (INIS)

We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.).

488

Hyperoxia-induced acute lung injury using a pig model. Correlation between MR imaging and histologic results  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to correlate MR imaging findings with pathology in experimental hyperoxia-induced acute lung injury, which has similar pathology to diffuse alveolar damage (DAD). Seventeen Yorkshire pigs were studied. These animals were exposed to more than 80% oxygen for 24, 48, 72, and 96 hours in a sealed cage. The lungs were removed and inflated with air infused through the trachea, and then examined by both MRI and high-resolution CT (HRCT). T1-weighted spin-echo (T1WSE), T2-weighted fast (T2WFSE), and half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequences were performed. Severity in MR findings and signal-to-noise ratios (SNR) on MR images were well correlated with pathological scores. CT values were also correlated well with pathologic scores. Abnormal SNR values were obtained from a pathological score of 5, whereas abnormal CT values were obtained from a pathological score of 15. ...

2001-06-01

489

Feasibility study of computed tomography colonography using limited bowel preparation at normal and low-dose levels study  

Energy Technology Data Exchange (ETDEWEB)

The purpose was to evaluate low-dose CT colonography without cathartic cleansing in terms of image quality, polyp visualization and patient acceptance. Sixty-one patients scheduled for colonoscopy started a low-fiber diet, lactulose and amidotrizoic-acid for fecal tagging 2 days prior to the CT scan (standard dose, 5.8-8.2 mSv). The original raw data of 51 patients were modified and reconstructed at simulated 2.3 and 0.7 mSv levels. Two observers evaluated the standard dose scan regarding image quality and polyps. A third evaluated the presence of polyps at all three mSv levels in a blinded prospective way. All observers were blinded to the reference standard: colonoscopy. At three times patients were given questionnaires relating to their experiences and preference. Image quality was sufficient in all patients, but significantly lower in the cecum, sigmoid and rectum. The two observers correctly identified respectively 10/15 (67%) and 9/15 ...

2007-12-15

490

Ewing's sarcoma of the sacrum  

International Nuclear Information System (INIS)

A lytic lesion with softtissue extension in the sacrum of a 47-year old man was needle-biopsied under computed tomographic (CT) guidance using an 18-gauge cutting needle. The cytologic appearance of the lesion and immunohistochemical staining were diagnostic of Ewing's sarcoma. Specifically, a new marker (O13) for the presence of glycoprotein p30/32 mic2 in Ewing's sarcoma was utilized. (orig.).

491

Evaluation of NucliSens easyMAG for automated nucleic acid extraction from various clinical specimens.  

Science.gov (United States)

The objectives of this study were to evaluate the performance of the NucliSens easyMAG platform for nucleic acid extraction from different clinical specimens compared to NucliSens miniMAG platform and manual QIAGEN extraction. The NucliSens easyMAG and the NucliSens miniMAG showed equal performance on 215 throat swabs since real-time nucleic acid sequence-based amplification scored the same samples positive for Mycoplasma pneumoniae (n=9) and Chlamydia pneumoniae (n=5) RNAs, although internal control RNA was slightly better detected with the NucliSens easyMAG (99.3% versus 96.8%). NucliSens easyMAG extracted nucleic acids more efficiently (higher recovery and/or fewer inhibitors) compared to QIAGEN extraction by showing, on average, lower Ct values in real-time LightCycler PCR, although 4 individual specimen out of 45 were found positive only with QIAGEN. For nine M. pneumoniae-positive throat swabs, the mean difference in Ct values between ...

2006-12-13

492

Estimation of organ dose during radiological and computer tomographic examinations with calculations of the somatically significant doses  

Energy Technology Data Exchange (ETDEWEB)

The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different.

1980-10-01

493

Estimation of organ dose during radiological and computer tomographic examinations with calculations of the somatically significant doses  

International Nuclear Information System (INIS)

The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different. (orig.).

1980-01-01

494

Different phenotypes of lattice corneal dystrophy type I in patients with 417C>T (R124C) and 1762A>G (H572R) mutations in TGFBI (BIGH3)  

UK PubMed Central (United Kingdom)

PurposeTo describe clinical data and to characterize mutations in the transforming growth factor beta-induced (TGFBI) gene in patients from three unrelated Chilean...Full Text Available

495

Cystic lesions of the seminal vesicles. Demonstration by MRI. Zystische Raumforderungen der Samenblasen. Darstellung mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Between October 1990 and March 1991, 8 patients with cystic lesions in the region of the posterior bladder wall, the seminal vesicles and the prostate were examined by MRI. In all cases there was accurate characterisation of the lesion and of its anatomy. In 3 patients with abnormalities in the retrovesical space there was very good agreement with the operative findings. 4 patients were treated conservatively. In these patients there was good agreement with the findings on cystoscopy, CT and sonography. (orig.).

1992-07-01

496

Computed tomography of intrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Intrahepatic cholangiocarcinoma is an uncommon tumor as primary hepatic neoplasm. Five cases of cholangiocarcinoma, mass forming peripheral type, are reported about its CT findings. They were manifested as a poorly marginated low density mass with a irregular stellate area. In one case, a cut section of the gross specimen following surgery showed a central callagenous scar and vessels within the necrotic tumor. (author).

497

Computed tomographic findings of intrahepatic peripheral cholangiocarcinoma  

International Nuclear Information System (INIS)

Cholangiocarcinoma is synonymous with bile duct carcinoma, and can originate in a small intrahepatic bile duct (peripheral type), a major intrahepatic duct including the hepatic hills, an extrahepatic duct, or near the papilla of Vater (central type). In a sense bile duct carcinoma of the peripheral type is cholangiocarcinoma of the liver; it has the same gross configuration as hepatocellular carcinoma, resulting in difficulty to differentiate on the CT. The authors studied CT findings of 14 cases of pathologically proven peripheral type cholangiocarcinoma of the liver during the last 4 years. The results were as follows: 1. Of 14 cases, 8 were female and 6 were male, and the age ranged from 5th to 7th decades. 2. Preoperative clinical diagnosis were as follows: hepatoma 8 cases, abscess 5 cases and metastasis 1 case in order of frequency. 3. Diagnosis were confirmed by hepatic lobectomy in 7 cases, wedge resection in 5 cases and needle biopsy ...

1986-08-01

498

Comparative evaluation of Computed Tomography and Magnetic Resonance Imaging (1.5 T) in the detection of brain metastases  

International Nuclear Information System (INIS)

Forty-four patients with small cell carcinoma of the bronchus underwent CT and MR studies of the brain to detect cerebral metastases. All patients were studied with contrast-enhanced CT scans, short (T1-weighted) and long (T2-weighted), spin-echo (SE) and FLASH 90 grades sequences were also obtained. A quantitative comparison of the results was carried out to assess the sensitivity of the different techniques in the detection of brain metastases according to lesion diameter. Metastases were identified in 19/44 patients (43%). All techniques detected the lesions >2 cm; of the metastases <2 cm, 63/124 (51%) were detected only by GdDTPA SE-T1 and FLASH sequences and 11 more (9%) only by Gd-DTPA SE-T1 scans. All the lesions identified oh enhanced CT scans or on T2-weighted images were easily detected by Gd-DTPA scans. CT sensitivity was higher than that of pre-contrast SE-T1 and FLASH studies and only ...

1991-01-01

499

CT colonography: techniques of visualization and findings; CT Kolonographie: Techniken der Visualisierung und Befundung  

Energy Technology Data Exchange (ETDEWEB)

Evaluation and interpretation of CT colonography is based on both 2D and 3D techniques. The 2D techniques are popular mainly because the time needed for evaluation is short. The 3D techniques allow better definition than the 2D techniques, especially of polyps close to folds or at the base of a fold. The evaluation strategies generally accepted so far (primarily 2D, with 3D for problem cases, or vice versa) demand knowledge of both 2D and 3D techniques. Newer 3D visualization techniques help make it possible to acquire more complete and faster recording particularly of areas that are not easily accessible to endoscopic examination. These user-friendly developments are thus well suited to improving the detection and the security of detection of polyps. It must be remembered that experience and the knowledge of associated artifacts and the limitations they can impose on diagnosis are prime requirements for the implementation of such visualization techniques. (orig.) ...

2008-02-15

500

CF findings of bowel infarction in 56 surgical patients, 5 of whom with reversible ischemia; Aspetti alla tomografia computerizzata dell'infarto intestinale. 56 pazienti sottoposti a interventi chirurgico di cui 5 con ischemia mesenterica reversibile.  

Energy Technology Data Exchange (ETDEWEB)

Bowel infarction is a rare and typical condition of the elderly; despite improvements in diagnostic imaging and vascular surgery, bowel infarction remains a major cause of acute abdomen, with mortality rates ranging 70-80%. Diagnosis on often late because clinical signs, laboratory data and radiologic findings are a specific. The authors investigated radiographic and particular CT patterns of intestinal infraction in 56 patients submitted to surgery within 12 hours of admission. We also report the CT findings of 5 of these patients who had reversible mesenteric ischemia. CT is more sensitive than radiography and does not exhibit the limitations of angiography (i.e., invasiveness, radiation exposure and complex organization). Therefore CT can presently be considered the method of choice in patients with suspected bowel infarction. [Italian] L'infarto intestinale rappresenta una malattia rara e ...

1999-04-01