implications for treatment. In M.A. Chesney 8,. R. H. Rosenman (Eds.) Anqer and hostility in cardiovascular and behavioral disorders (pp. 103-126). ...
The historical back ground of free electron laser (FEL) and the present status of development and utilization research of FEL facilities in the world are explained. Eight facilities such as Stanford Univ., UCSB, Duke Univ., Vanderbilt Univ., LANL AFEL (USA), FOM FELIX (Netherlands), N-lands LURE CLIO (France) and FELI (Japan) can be used. The principle of FEL generation process is that free electrons move in a zigzag direction to generate radio waves which interfere with each other to become monochromatic light and then free electron laser. The benefits of FEL, quality of electron beam, limit of wave length of FEL, problems and development of utilization technologies of FEL are explained. (S.Y.)
This digest paper presents the theoretical project of a fission engine for space ship as imagined by Y. Ronen from the Ben-Gourion Univ. (Israel). In this engine, the combustion chamber is covered with metastable {sup 242}Am thin sheets. The fission reaction is triggered with a bombardment of neutrons and the fission fragments ionize a gas (hydrogen, for instance) which is overheated and ejected through the engine nozzle. (J.S.)
Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance dose values of thoracoabdominal babygrams and abdomen X-rays in DvHK could be ...
Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance dose values of thoracoabdominal babygrams and abdomen X-rays in DvHK could be reduced in the last ...
Norway is a member of Annex 29, 'Ground-Source Heat Pump Systems Overcoming Technical and Market Barriers' (2004-2006), organized under the umbrella of the International Energy Agency (IEA) and the IEA Heat Pump Programme (HPP). The 7 participating countries are Austria (Operating Agent), Canada, Japan, Norway, Spain, Sweden and the USA. The Norwegian participation is financed by ENOVA SF, and SINTEF Energy Research is responsible for planning and carrying out the Norwegian activities. This report provides a status for ground-source heat pump (GSHP) systems in Norway with regard to state-of-the-art technology, installation examples, geological data, costs and market opportunities. A Norwegian Internet home page for ground-source heat pump systems (www.energy.sintef.no/prosjekt/Annex29) is also presented. GSHP systems in Norway are classified as direct systems (groundwater and soil/ground) and indirect closed-loop systems (vertical-rock and horizontal-soil/ground). The vast majority of ...
Attention was focused on the fission process in light nuclear systems. A model calculation based on the transition-state model of nuclear fission was applied to [sup 47]V fission as populated through multiple entrance channels and to fusion-fission cross sections for production of [sup 28]Al through three different entrance channels. Angular distributions are shown for different mass channels of the [sup 29]Si+[sup 27]Al reaction at E[sub lab] = 125 MeV. Pronounced structure is seen in the symmetric and near-symmetric fission channels from the [sup 24]Mg+[sup 24]Mg reaction; cross sections for binary fragment emission are shown for E[sub lab] = 90 MeV. A large Bragg-curve detector was used in this experiment. Ways to optimize detector response were studied; in addition, the Bragg detector was instrumented with an internal position-sensitive multiwire proportional counter.
This report briefly describes the studies on the mechanism of in vivo DNA repairing by the author in Research Reactor Institute, Kyoto Univ. for the past 30 years. First, the ability of UV radiation to induce transformation was investigated with viral DNA. The formation of thymine-thymine dimer was found harmful to organisms and such dimers were removable by UV-radiation at a low frequency. The mutability was determined in three different E.coli strains with mutator gene, mutT, mutS or mutL. The ability to excise 8-oxoguanin developed in primer DNA was deficient in mutT and miss-pairing left after DNA replication could not be recovered in mutL and mutS strains. Further, DNA repairing mechanism was investigated in other microorganisms; single-strand cleavage caused by exposure to BNCB radiation (boron-neutron-captured beam) could not be repaired in E. coli. Whereas for Deinococcus radiodurans, of which survival rate was not decreased by #gamma#-ray radiation at 5 ...
Calculations have been made to determine the production of "1"8"8W from "1"8"6W in several US fission reactor systems, e.g., Fast Flux Test Facility (FFTF), the High Flux Isotope Reactor (HFIR), and the Advanced Test Reactor (ATR). Important input to these calculations are the cross-section parameters for "1"8"6W, "1"8"7W, and "1"8"8W. Only two values have been measured for "1"8"7W and none for "1"8"8W. Consequently, results from integral measurements play a crucial role in determining the "1"8"7W and "1"8"8W values. This has been studied for irradiations in the FFTF and the Oregon State Univ. (OSU) research reactor. Short irradiation of enriched "1"8"6W in both the FFTF and the OSU reactors have produced #mu#Ci/g quantities of "1"8"8W/"1"8"8Re. Measurements were made of the "1"8"8W gamma ray emission. These results were incorporated with other available data to provide more accurate "1"8"8W calculations in fission reactor systems.
This Report of activity displays the work developed at Centre d`Etude Nucleaires de Bordeaux-Gradignan (CENBG) in the period 1995-1996. A number of 68 short progress notes are presented in the fields of Cosmic particles (3), Nuclear Astrophysics (4), High Spins-Large Deformations (8), Basic Interactions (9), Exotic Nuclei (10), Hybrid Systems (4), Theoretical Physics (28), Cellular Microanalysis by means of Nuclear Probes (3) and Technical Development (3). The main problems attacked at CENBG, established as orientations by scientific board of IN2P3 (CENBG is a UMR of Bordeaux-1 Univ. and CNRS-IN2P3) are the following: the research of Majorana/Dirac nature of neutrino (in the framework of NEMO Experiment) in relation with the problem of origin of mass in the Universe and the cosmological puzzle of dark matter, the investigation of the origin of high energy (20 to 200 GeV) cosmic radiation (in the framework of CELESTE Experiment), the study of extreme issues in ...