Abstract In this paper, a Cognitive Radio Based Medium Access Control (CR-MAC) protocol for Wireless Sensor Body Area Networks (WSBAN) that utilizes cognitive radio transmission is proposed. In this proposal, the sensor nodes are classified into nodes of life-critical health information and nodes of non-critical health information. The CR-MAC protocol prioritizes the critical packets access to the transmission medium by transmitting them with higher power while transmitting lower priority packets using lower transmission power. At the receiver, a higher priority packet experiences collision only when there are more than one critical packettransmission at the same transmission slot while non critical packets experience collision when there are more than one ...
Physical-layer network coding (PNC) is a promising approach for wireless networks. It allows nodes to transmit simultaneously. Due to the difficulties of scheduling simultaneous transmissions, existing works on PNC are based on simplified medium access control (MAC) protocols, which are not applicable to general multi-hop wireless networks, to the best of our knowledge. In this paper, we propose a distributed MAC protocol that supports PNC in multi-hop wireless networks. The proposed MAC protocol is based on the carrier sense multiple access (CSMA) strategy and can be regarded as an extension to the IEEE 802.11 MAC protocol. In the proposed protocol, each node collects information on the queue status of its neighboring nodes. When a node finds that there is an opportunity for some of its neighbors to perform PNC, it notifies its corresponding neighboring nodes and initiates the process of packet exchange using PNC, with the ...
Automatic Repeat Request (ARQ) is an effective technique for reliable transmission of packets in wireless networks. In ARQ, however, only a few erroneous bits in a packet will cause the entire packet to be discarded at the receiver. In this case, it's wasteful to retransmit the correct bit in the received packet. The partial packet recovery only retransmits the unreliable decoded bits in order to increase the throughput of network. In addition, the cooperative transmission based on Interleave-division multiple-access (IDMA) can obtain diversity gains with multiple relays with different locations for multiple sources simultaneously. By exploring the diversity from the channel between relay and destination, we propose a relay-assisted partial packet recovery in CDMA wireless network to improve the performance of ...
As network bandwidth continues to grow and longer paths are used to exchange large scientific data between storage systems and GRID computation, it has become increasingly obvious that there is a need to deploy a packet drop avoidance mechanism into network transmission protocols. Current end-to-end congestion avoidance mechanisms used in Transmission Control Protocol (TCP) have worked well on low bandwidth delay product networks, but with newer high-bandwidth delay networks they have shown to be inefficient and prone to unstable. This is largely due to increased network bandwidth coupled with changes in internet traffic patterns. These changes come from a variety of new network applications that are being developed to take advantage of the increased network bandwidth. This paper will examine the end-to-end congestion avoidance mechanism and perform a step-by-step analysis of its theory. In addition we will propose an ...
Transmission Control Protocol (TCP) provides mechanisms for reliable data communications. Although it works well in wired networks, it fails to offer satisfactory performance in lossy and wireless environments. And in the multi-hop wireless infrastructure, packet delivery suffers high cumulative loss rate if traveling over multiple wireless hops. The Selective acknowledgment (SACK) is one header option that might be used to combat segment corruptions in air channels. In this paper, an alternative set of flow control mechanisms is proposed to handle high packet loss rate in a wireless medium. Using a measurement-based mechanism, sustainable segment delivery is achievable through a novel size-reduction method. Multiple segment retransmission mechanisms are introduced to reduce successive tim...
Wireless mesh networks can provide low-cost solutions for extending the reach of wireless access points by using multi-hop routing over a set of stationary wireless routers. The routing protocol for these networks may need to address quality considerations to meet the requirements of the user. In this paper, we present a quality based routing protocol for wireless mesh networks that tries to maximize the probability of successful transmissions while minimizing the end-to-end delay. The proposed routing protocol uses reactive route discoveries to collect key parameters from candidate routes to estimate the probability of success and delay of data packets transmitted over them. To achieve accurate route quality assessments, a new route quality metric is proposed that uses performance models ...
Multicast transmission has several distinctive traits as opposed to more commonly studied unicast networks. Specially, these include (i) identical packets must be delivered successfully to several nodes, (ii) outage could simultaneously happen at different receivers, and (iii) the multicast rate is dominated by the receiver with the weakest link in order to minimize outage and retransmission. To capture these key traits, we utilize a Poisson cluster process consisting of a distinct Poisson point process (PPP) for the transmitters and receivers, and then define the multicast transmission capacity (MTC) as the maximum achievable multicast rate times the number of multicast clusters per unit volume, accounting for outages and retransmissions. Our main result shows that if $\\tau$ transmission attempts are allowed in a multicast cluster, the MTC is $\\Theta\\left(\\rho k^{x}\\log(k)\\right)$ where $\\rho$ ...
Denial of service attacks (DoS) can cause significant financial damages. Flooding and Malicious packets are two kinds of DoS attacks. This paper presents a new security approach which stops malicious packets and prevents flooding in the critical systems. New concepts of packet stamp a dynamic-multi-communication-point mechanism has been identified for this proposed approach to make the prevention of flooding attacks easier and the performing of malicious packet attacks harder. In addition, dynamic key encryption technique has been adapted as a part of the proposed approach to enhance its functionality.
This paper presents a study of feasibility of different existing methodologies linked to field's data acquisition from remote meteorological stations. The data transmission serves to collect field's meteorological information, such as temperature, humidity and radiation. In our study the experimental data is registered in a weather station located about 100 km from University of Almeria. Various existing techniques are studied, especially Radio, GSM (global system of mobile communication) and GPRS (general packet radio service). In the result of these studies has been designed a system of field's data acquisition (herein referred as Meteologger) which we are going to present in this paper. The system is based on an ATmega 16 microcontroller, which scans 8 sensors together at any programmable intervals. This paper presents the study of the mentioned project, application and some main characteristics of the prototype system and its program. We ...
Multi-fiber WDM networks are becoming the major telecommunication platforms for transmitting exponentially increasing data traffic. While today's networks are mainly providing circuit-switched connections, optical packet-switching technologies have been investigated for years, aiming at achieving more efficient utilizations of network resources. In this paper, we have evaluated, for the first time, the packet-loss performance of multi-fiber optical packet switches (MOPS). Our main contributions are threefold. Firstly, we have proposed simple and accurate analytical models for analyzing packet-loss performance of (i) the most fundamental MOPS configuration, (ii) MOPS equipped with fiber delay lines (FDLs) and (iii) shared wavelength converters (SWCs). Secondly, we have shown that the MOPS n...
Demands for electric power system, which include not only minimization of generation cost but also protection of environmental condition and maintenance of transmission security, have been diversified The priority of these objectives may change according to load change, weather, and other conditions. Since these objectives are usually in a trade-off relationship and generally non-commensurable, it is difficult to handle by conventional optimization of a single objective function. This report describes multi-objective scheduling of thermal power system. The adaptability of three performance indicies, such as economic efficiency, NO{sub x} emission, and transmission security, to operators are defined by membership functions in fuzzy set theory. coordinated solution in which the adaptability of operators is maximized can be obtained by maximizing the fuzzy decision-making function composed of the adaptability index for each ...
Many mobile ad hoc network protocols use simple flooding, in order to adapt to changes in time varying network topology. Most of the times, a network-wide flood results in redundant packets and increases network congestion, probability of packet collision, low utilization of available bandwidth, and most important, higher power consumption. In this paper, we propose a new cross-layer broadcast scheme to minimize broadcast traffic in mobile ad hoc networks. Our scheme is based on use of received signal strength indicator, RSSI, value to reduce the number of broadcast packets. The effectiveness of the proposed technique is verified using simulations.
Applying for AAO scheduled time Applying for AAT service time Applying for Gemini Time Travel and Accommodation AAT Schedule UKST Schedule Instrument capabilities and...
This report deals with the selection of a data communication system for a remote metering system. It covers the following three types of systems: fiber optic, telephone line, and radio packet. It provides a methodology for selecting a communication system for a given remote metering system and a method for comparing costs.
This report presents the data and results of a site specific case study comparing costs of an overhead line with an underground circuit traversing the same route. The costs used for the overhead line are actual numbers for a line scheduled to be built by a utility. The underground circuit costs were developed using the same criteria of line rating, contingencies, and location. Often cost comparisons between overhead and underground lines are made using figures taken from studies with widely varying assumptions. This project attempts to provide a comparison by studying the costs of overhead and underground lines following the same route and using the same design assumptions. Caution must be used, however, in extending the results of this study beyond its original intent. It is site-specific and may be representative of only one area of the country. 9 refs., 23 figs., 18 tabs.
This paper describes a Honshu-Shikoku linking transmission cable building plan and its technical features. The Chugoku District and the Shikoku District are supplied with power currently by the Chugoku-Shikoku trunk line of 220,000 volts. To cope with the anticipated power shortage, a plan was established to install power cables for 500,000 volts on the Honshu-Shikoku connecting bridge. The plan calls far an installation length of 127.4 km and a transmission capacity of 1.2 million kW per line. The cable installation on the Seto Bridge was completed already, the construction is now in the peak period for building steel towers on the land sections, and laying overhead cables and underground cables. Commencement of the operation is scheduled 1994 on one liner, and 2000 on two lines. The technical features include the Japan's first large-capacity, long-distance underground transmission cable ...
Los Alamos National Laboratory (LANL) is a unique facility covering over 43 square miles. The Emergency Management and Response Office (EM&R) is required to respond, provide Incident Command (IC), and coordination for all Laboratory emergencies. This requires IC`s and support staff to respond to the actual scene of the incident. Since the IC is under numerous constraints and stress, the office wanted the capability of locating the EM&R vehicles on an electronic map. An automated vehicle location (AVL) system was required for the additional safety of the emergency response personal. The requirements for the AVL system include total automatic tracking and low cost. After careful consideration, it was determined that the most efficient and cost effective system would be based on packet radio technology as the transmission media. The location is determined by the Department of Defense Global Positioning System (GPS). The system that was ...
Based on the exact results obtained by Bethe ansatz, we demonstrate the existence of stable bound pair (BP) wave packet in Bose Hubbard model with arbitrary on-site interaction U. In large-U regime, it is found that an incoming single-particle (SP) can coherently pass through a BP wave packet and leave a coherent shift in the position of it. This suggests a simple scheme for constructing a BP charge qubit to realize a quantum switch, which is capable of controlling the coherent transport of one and only one photon in a one-dimensional waveguide.
Data communication in a computer network environment is facing serious security threats from numerous sources such as viruses, worms, Zombies etc. These threats can be broadly characterized as internal or external security threats. Internal threats are mainly attributed to sneaker-nets, utility modems and unauthorized users, which can be minimized by skillful network administration, password management and optimum usage policy definition. The external threats need more serious attention as these attacks are mostly coming from public networks such as Internet. Frequency and complexity of such attacks is much higher as compared to internal attacks. This paper presents a host based network layer screening of external and internal IP packets for logging, analyzing and real-time detection of possible IP spoofing and Denial of Service attacks. This work can also be used in tuning security rules definition for gateway firewalls. Software has been developed which ...
Network security is a discipline that focuses on securing networks from unauthorized access. Given the Escalating threats of malicious cyber attacks, modern enterprises employ multiple lines of defense. A comprehensive defense strategy against such attacks should include (I) an attack detection component that deter- mines the fact that a program is compromised, (2) an attack identification and prevention component that identifies attack packets so that one can block such packets in the future and prevents the attack from further propagation. Over the last decade, a significant amount of research has been vested in the systems that can detect cyber attacks either statically at compile time or dynamically at run time, However, not much effort is spent on automated attack packet identification or attack prevention. In this paper we present a unified solution to the problems mentioned above. We implemented this solution after ...
...2010-10-01 2010-10-01 false Use of Federal Supply Schedules. 8.404 Section 8.404 Federal...REGULATION ACQUISITION PLANNING REQUIRED SOURCES OF SUPPLIES AND SERVICES Federal Supply Schedules 8.404 Use of Federal Supply...
One of the essential steps in the main scope Project Management is the Time Management made by the planning and control of the project schedule. In this work is presented the resource constrained scheduling problem beyond its mathematical formulation and a review of papers about this issue. In sequence is presented a practical example of this model considering a simplified model of an engineering project schedule of oil production equipment. The results obtained with the model application are shown and the conclusions about the work with resource constrained scheduling problems. (author)
... terminals, popular tourist spots, political rallies, and subway ... Dynamic scheduling of a two-class queue with ... Stochastic Processes 2nd ed. Wiley. ...
This document is the annual update of the FFTF and Advanced Reactors Transition Program Resource Loaded Schedule for FY 2002 using current project direction and authorized funding levels
The fuel economy of different types of trucks was simulated. Preliminary vehicle simulation activity took place in order to determine a feasible range of vehicle fuel efficiency improvements that could be obtained. Another objective was to provide a start to the Systems Analysis road mapping process in order to identify significant improvements for future studies at minimal costs. Technology improvements to all types of trucks were categorized in relation to engine improvements, the incorporation of continuously variable transmissions, hybrid drivetrain technology and improvements in aerodynamic drag, rolling resistance and weight reduction. The trucks which had the largest national impact were identified from data on vehicles, miles driven, fuel consumption and exhaust gases. The study involved Class 2B utility trucks, Class 6 enclosed delivery trucks, Class 8 transit buses and Class 8 tractor trailer trucks because they best represented the truck fleets in terms ...
This report presents a reassessment of the design of Resistive Cryogenic Cable Systems with regard to dielectric material selection, thermal insulation selection, conductor design, and refrigeration subsystem design. An algorithm using test data generated as part of the program and available from the literature was developed and used to assess the driving parameters for system cost analysis. The results of this cost sensitivity analysis are presented. An electric utility, Public Service Electric and Gas of New Jersey (PSE and G), performed an economic viability evaluation comparing two selected Resistive Cryogenic Cable Systems to a conventional cable system (high pressure oil-filled). The comparison was made for a 35-mile network application on the PSE and G transmission system scheduled to be placed in service in 1995. Consideration was given to equipment capital, installation, and operating costs. It was concluded that a Multilayer Vacuum ...
Current Intrusion Detection System (IDS) technology is not suited to be widely deployed inside a Supervisory, Control and Data Acquisition (SCADA) environment. Anomaly- and signature-based IDS technologies have developed methods to cover information technology-based networks activity and protocols effectively. However, these IDS technologies do not include the fine protocol granularity required to ensure network security inside an environment with weak protocols lacking authentication and encryption. By implementing a more specific and more intelligent packet inspection mechanism, tailored traffic flow analysis, and unique packet tampering detection, IDS technology developed specifically for SCADA environments can be deployed with confidence in detecting malicious activity.
The scattering of atoms by a resonance standing light wave is considered under conditions when the lower of two resonance levels is metastable, while the upper level rapidly decays due to mainly spontaneous radiative transitions to the nonresonance levels of an atom. The diffraction scattering regime is studied, when the Rabi frequency is sufficiently high and many diffraction maxima are formed due to scattering. The dynamics of spontaneous radiation of an atom is investigated. It is shown that scattering slows down substantially the radiative decay of the atom. The regions and characteristics of the power and exponential decay are determined. The adiabatic and nonadiabatic scattering regimes are studied. It is shown that the wave packets of atoms in the metastable and resonance excited states narrow down during scattering. A limiting (minimal) size of the wave packets is found, which is achieved upon nonadiabatic scattering in the case of a ...
The flexibility of bus rapid transit (BRT) in scheduling is one of the greatest differences with traditional buses. In order to improve BRT operation quality, the paper studied the headway optimization and scheduling combination of BRT vehicles. A model has been established to minimize passengers travel costs and vehicles operation cost, and constraints included passenger volume, time, and frequency. The scheduling combination was composed by normal, zone, and express scheduling. The model was solved by genetic algorithm of variable-length coding. The result of the numerical case shows that: the optimization results can save 69.92% cost. The sensitivity analysis shows that, under higher traffic volume or lower speed, the travel cost can be reduced through reasonable scheduling combination....
The propagation of bradyon and tachyon wave functions can be compared by considering them as cases of normal and anomalous dispersion and using the ideas of Brillouin which where developed in order to describe the propagation of light in a transparent medium near an adsorption line. It is found that if a wave packet, or pulse, is formed using a superposition of waves moving only in the positive x direction, including both positive energies, it will propagate superluminally for both bradyons and tachyons. If non-physical states, imaginary moments and energies, are included in the superposition, both types of waves will propagate subluminally and remain within the light cone. This last result has also been obtained by Fox, Kuper and Lipson and Strnad and Kodre for tachyons when they included imaginary energies in their superposition. However, these approaches allow the tachyon to be localizable in space and can lead to divergences in the wave ...
This document defines the requirements for the GPRS (General Packet Radio Service) infrastructure as part of the Dutch Smart Meter Specification. In this document all requirements originating from the NTA 8130, or additionally surveyed by a delegation of the Dutch grid operators, are presented in tables. Each requirement is tightly connected to one or more business use cases presented in the document. The ultimate goal of this procedure is to reduce ambiguity of the requirements due to a better understanding of the requirements.
In Experiment I, lever pressing by squirrel monkeys was maintained under a sequence of variable-interval, multiple variable-interval variable-interval, and multiple variable-interval extinction schedules...Full Text Available
After discrimination training on a multiple variable-interval extinction schedule of food reinforcement, pigeons were placed on the uncued or mixed version of the same schedule and allowed to make...Full Text Available
A fast production scheduling algorithm suitable for generation expansion studies is described in this paper. It can handle several independent rivers, thermal plants, pumped storage plants, import, export, and internal non-firm markets. Inflows and load are deterministic and a one-reservoir limit is imposed on each river. The scheduling problem is formulated as a generalized network problem which is efficiently solved by an adaption of the simplex method. The algorithm is part of a program developed by Hydro-Quebec to conduct preliminary evaluations of alternative expansion plans. The program and the scheduling algorithm are presented.
A fast production scheduling algorithm suitable for generation expansion studies is described in this paper. It can handle several independent rivers, thermal plants, pumped storage plants, import, export, and internal non-firm markets. Inflows and load are deterministic and a one-reservoir limit is imposed on each river. The scheduling problem is formulated as a generalized network problem which is efficiently solved by an adaption of the simplex method. The algorithm is part of a program developed by Hydro-Quebec to conduct preliminary evaluations of alternative expansion plans. The program and the scheduling algorithm are presented.
This paper uses multi-pass iteration particle swarm optimization (MIPSO) to solve short term hydroelectric generation scheduling of a power system with wind turbine generators. MIPSO is a new algorithm for solving nonlinear optimal scheduling problems. A new index called iteration best (IB) is incorporated into particle swarm optimization (PSO) to improve solution quality. The concept of multi-pass dynamic programming is applied to modify PSO further and improve computation efficiency.The feasible operational regions of the hydro units and pumped storage plants over the whole scheduling time range must be determined before applying MIPSO to the problem. Wind turbine power generation then shaves the power system load curves. Next, MIPSO calculates hydroelectric generation scheduling. It beg...
The United States Air Forces air mobility command is responsible for creating a schedule and executing that schedule for a large-scale air mobility network that encompasses aircraft with prioritized missions. Aerial ports (airports) can process or park a maximum number of aircraft, called the maximum on ground (MOG). As the schedule changes due to disruptions, such as equipment failure or weather, the MOG constraint can cause the new schedule to be infeasible. Traditionally, re-planning the channel route schedule to adhere to MOG constraints has been a manual process that usually stops after the first feasible set of changes is found, due to the challenges of large amounts of data and urgency for a re-plan. We extend Bertsimas and Stocks integer program formulation for the commercial airli...
When quantum molecular dynamics (QMD) is applied to the nuclear reactions in theory of relativity region, a number of problems arise, and in order to solve them, the prescription of the extension of ordinary nonrelativistic QMD is introduced, and the analysis of proton incidence reaction by using it is shown. By introducing the interaction corresponding to Lorentz transformation, the problems were solved. QMD is the semiclassical simulation that treats the motion of nucleons represented by Gauss wave packet. The motion of wave packet center is expressed by Newton equations and two-nucleon collision. The introduction of the interaction corresponding to Lorentz transformation is explained. As the result of the introduction, through the relative distance of two particles, the interaction becomes to depend on momentum. The phase distribution function of one body corresponding to Lorentz transformation is used for calculating the final state Pauli ...
Probabilistic broadcast has been widely used as a flooding optimization mechanism to alleviate the effect of broadcast storm problem (BSP) in mobile ad hoc networks (MANETs). Many research studies have been carried-out to develop and evaluate the performance of this mechanism in an error-free (noiseless) environment. In reality, wireless communication channels in MANETs are an error-prone and suffer from high packet-loss due to presence of noise, i.e., noisy environment. In this paper, we propose a simulation model that can be used to evaluate the performance of probabilistic broadcast for flooding in noisy environment. In the proposed model, the noise-level is represented by a generic name, probability of reception (pc) (0<=pc<=1), where pc=1 for noiseless and <1 for noisy environment. The effect of noise is determined randomly by generating a random number \\zeta (0<=\\zeta<1); if \\zeta<=pc means the packet is successfully ...
To facilitate the evaluation of alternate canister designs, 2 canisters were outfitted with thermocouples at elevations of 1/2, 3 1/2, and 6 1/2 inches from the canister bottom. The canisters were fabricated from two inch diameter schedule 10 and two inch diameter schedule 40 stainless steel pipe. Each canister was filled with approximately 2 kilograms of 49 wt percent lanthanide (Ln) loaded 25SrABS glass during 5 inch Cylindrical Induction Melter (CIM5) runs for TTR Tasks 3.03 and 4.03. Melter temperature, total mass of glass poured, and the glass pour rates were almost identical in both runs. The schedule 40 canister has a slightly smaller ID compared to the schedule 10 canister and therefore filled to a level of 9.5 inches compared to 8.0 inches for the schedule 40 canister. The schedule 40 canister had an empty mass of 1906 grams compared to 919 grams for ...
This paper uses multi-pass iteration particle swarm optimization (MIPSO) to solve short term hydroelectric generation scheduling of a power system with wind turbine generators. MIPSO is a new algorithm for solving nonlinear optimal scheduling problems. A new index called iteration best (IB) is incorporated into particle swarm optimization (PSO) to improve solution quality. The concept of multi-pass dynamic programming is applied to modify PSO further and improve computation efficiency. The feasible operational regions of the hydro units and pumped storage plants over the whole scheduling time range must be determined before applying MIPSO to the problem. Wind turbine power generation then shaves the power system load curves. Next, MIPSO calculates hydroelectric generation scheduling. It begins with a coarse time stage and searching space and refines the time interval between two time stages and the ...
This paper describes a study of comparison of global and one-dimensional local optimization methods to operating system scheduler tuning. The operating system scheduler we use is the Linux 2.6.23 Completely Fair Scheduler (CFS) running in simulator (LinSched). We have ported the Hackbench scheduler benchmark to this simulator and use this as the workload. The global optimization approach we use is Particle Swarm Optimization (PSO). We make use of Response Surface Methodology (RSM) to specify optimal parameters for our PSO implementation. The one-dimensional local optimization approach we use is the Golden Section method. In order to use this approach, we convert the scheduler tuning problem from one involving setting of three parameters to one involving the manipulation of one parameter. Our results show that the global optimization approach yields better response but the one- ...
This document presents a detailed schedule for the implementation of the strategy for managing defense remote-handled (RH) transuranic (TRU) waste. The baseline management strategy was defined in the Defense Remote-Handled Transuranic Waste Cost/Schedule Optimization Study and is summarized in this document. Also included are revised RH TRU waste inventory projections, current site management plans, a list of key decision points and milestones, and a discussion of uncertainties associated with management of RH TRU waste. The plans are summarized in a detailed schedule diagram and in an RH TRU waste work off diagram. 9 refs., 5 figs., 4 tabs.
The Michigan Electric Coordination Center (MEPCC), operated by Consumers Power and Detroit Edison Companies, has the responsibility for scheduling the Ludington pumped storage plant. Ludington has an extremely large economic effect on the Consumers Power and Detroit Edison Companies' system due to its size (over 1800 MW net demonstrated generating capability). This paper presents a dynamic programming algorithm for scheduling large pumped storage plants and shows how this method can be coordinated with the commitment of the thermal units of the system.
... f(i, k, α) if node k is the terminal node for ... under which the mean service rate at queue (i, k ... occur frequently in studies of stability in stochastic networks ...
we have a colloquium scheduled. Computing: register your machine and check our network security and visitor computer policies. For Our Information: Once arranged, please let us...
... of Award Costs (Schedule A), are free of material misstatement. An audit includes examining, on a ... support costs, materials and supplies, and the indirect costs. We found two material internal ...
Jan 31, 2006 ... Sick leave accrues at the rate of 1 hour for each 20 hour in a pay status. ... FERS: All periods of service are used in determining the FERS ...
Space Network Ku-band service. ... Completed GLAST mission schedule and budget assessment .... Utilize Ku band SN link (TDRSS) for science data return ...
This Contractor Performance Plan is a detailed execution plan covering fiscal years 2007 and 2008 that implements the Integration Project Baseline in a more aggressive cost and schedule approach.
This proceedings volume comprises 17 papers on the following subjects: Methane hydrates, compounds of gas and water; Compressed air stroage gas turbine power plants / Scheduled application for load levelling between varying wind power production and power demand; Modern pumped storage power stations in the GW range - the PSW Goldisthal example; Lead batteries - new developments and future applications; Alkaline battery systems for hybrid electric road vehicles; Lighium systems and their applications; Zinc/air cells; Hydrogen storage - metal hydride storage, compressed gas storage, LNG storage; Carbon nanofibres for hydrogen storage; Double-layer condensers - technology, cost, perslpectives; Supercondensers in motor vehicles; Superconducting magnetic energy stores; Flywheel storage - status report; Decentralized energy storage in the European integrated supply grid - the EU project DISPOWER; Intercontinental integration of power supply - perspectives of full-scale ...
Background Since 2007, sex has been the major mode of HIV transmission in China, accounting for 75% of new infections in 2009. Reducing sexual transmission is a major challenge for China...Full Text Available
The relationship between malaria transmission intensity and clinical disease is important for predicting the outcome of control measures that reduce transmission. Comparisons of hospital data...Full Text Available
BackgroundMother-to-Child Transmission (MTCT) of HIV remains the main mode of acquisition of HIV in children. Transmission of HIV may occur during pregnancy, delivery or breastfeeding....Full Text Available
A method, which estimates the lightning performance of high voltage transmission lines based on the Monte-Carlo simulation technique, is described in this paper. The average number of faults which occur in a transmission line, dividing them in single-phase and three-phase faults, as well as the average grounding resistances of the transmission lines are calculated. The method is applied, on several operating Greek transmission lines, showing good correlation between predicted and field observation results. The proposed method can be used as a useful tool in the design of electric power systems, aiding in the right insulation dimensioning of a transmission line.(author)
A robust transmission element for transmitting information between downhole tools, such as sections of drill pipe, in the presence of hostile environmental conditions, such as heat, dirt, rocks, mud, fluids, lubricants, and the like. The transmission element maintains reliable connectivity between transmission elements, thereby providing an uninterrupted flow of information between drill string components. A transmission element is mounted within a recess proximate a mating surface of a downhole drilling component, such as a section of drill pipe. To close gaps present between transmission elements, transmission elements may be biased with a "spring force," urging them closer together.
It is well known that for ergodic channel processes the Generalized Max-Weight Matching (GMWM) scheduling policy stabilizes the network for any supportable arrival rate vector within the network capacity region. This policy, however, often requires the solution of an NP-hard optimization problem. This has motivated many researchers to develop sub-optimal algorithms that approximate the GMWM policy in selecting schedule vectors. One implicit assumption commonly shared in this context is that during the algorithm runtime, the channel states remain effectively unchanged. This assumption may not hold as the time needed to select near-optimal schedule vectors usually increases quickly with the network size. In this paper, we incorporate channel variations and the time-efficiency of sub-optimal algorithms into the scheduler design, to dynamically tune the algorithm runtime considering the tradeoff between ...
... ice, hurricanes, and trees (less likely on high voltage transmission lines ) can bring down above ground power lines. Flooding, Leeching ground ...
Transtelephonic electrocardiographic transmission (TET) is the most widespread form of telecardiology since it enables clinicians to assess patients at a distance. The purpose of this study was to assess...Full Text Available
Glycine is a major inhibitory neurotransmitter in the spinal cord and brainstem. Recently, in vivo analysis of glycinergic synaptic transmission has been pursued in zebrafish using...Full Text Available
In mobile ad hoc networks (MANET), nodes usually belong to different authorities and pursue different goals. In order to maximize their own performance, nodes in such networks tend to be selfish and are not willing to forward packets for benefit of others. Meanwhile, some nodes may behave maliciously and try to disrupt the network through wasting other nodes resources in a very large scale. In this article, we present a reputation-based attack resistant cooperation stimulation (RACS) system which ensures that damage caused by malicious nodes can be bounded and cooperation among the selfish nodes can be enforced. Mathematical analyses of the system as well as the simulation results have confirmed effectiveness of our proposed system. RACS is completely self-organizing and distributed. It does not require any tamper-proof hardware or central management policy.
An algorithm for creating synthetic telescope images of Smoothed Particle Hydrodynamics (SPH) density fields is presented, which utilises the adaptive nature of the SPH formalism in full. The imaging process uses Monte Carlo Radiative Transfer (MCRT) methods to model the scattering and absorption of photon packets in the density field, which then exit the system and are captured on a pixelated image plane, creating a 2D image (or a 3D datacube, if the photons are also binned by their wavelength). The algorithm is implemented on the density field directly: no gridding of the field is required, allowing the density field to be described to an identical level of accuracy as the simulations that generated it. Some applications of the method to star and planet formation simulations are presented to illustrate the advantages of this new technique, and suggestions as to how this framework could support a Radiative Equilibrium algorithm are also given as an indication for ...
The antisymmetric many-body trial state which describes a system of interacting fermions is parametrized in terms of localized wave packets. The equations of motion are derived from the time-dependent quantum variational principle. The resulting fermionic molecular dynamics (FMD) equations include a wide range of semi-quantal to classical physics extending from deformed Hartree-Fock theory to newtonian molecular dynamics. Conservation laws are discussed in connection with the choice of the trial state. The model is applied to heavy-ion collisions with which its basic features are illustrated. The results show a great variety of phenomena including deeply inelastic collisions, fusion, incomplete fusion, fragmentation, neck emission, promptly emitted nucleons and evaporation. ((orig.)).
Recently several investigators reported on various means of generating cold plasma jets at atmospheric pressure. More interestingly, these jets turned out to be not continuous plasmas but trains of small high velocity plasma packets/bullets. However, until now little is known of the nature of these 'bullets'. Here we present experimental insights into the physical and chemical characteristics of bullets. We show that their time of initiation, their velocity and the distance they travel are directly dependent on the value of the applied voltage. We also show that these bullets can be controlled by the application of an external electric field. Using an intensified charge coupled device camera we report on their geometrical shape, which was revealed to be 'donut' shaped, therefore giving an indication that solitary surface ionization waves may be responsible for the creation of these bullets. In addition, using emission spectroscopy, we follow the evolution of ...
We investigate optimal resource allocation for delay-limited cooperative communication in time varying wireless networks. Motivated by real-time applications that have stringent delay constraints, we develop a dynamic cooperation strategy that makes optimal use of network resources to achieve a target outage probability (reliability) for each user subject to average power constraints. Using the technique of Lyapunov optimization, we first present a general framework to solve this problem and then derive quasi-closed form solutions for several cooperative protocols proposed in the literature. Unlike earlier works, our scheme does not require prior knowledge of the statistical description of the packet arrival, channel state and node mobility processes and can be implemented in an online fashion.
A fundamental Doppler-like but asymmetric wave effect that shifts received signals in frequency in proportion to their respective source distances, was recently described as means for a whole new generation of communication technology using angle and distance, potentially replacing TDM, FDM or CDMA, for multiplexing. It is equivalent to wave packet compression by scaling of time at the receiver, converting path-dependent phase into distance-dependent shifts, and can multiply the capacity of physical channels. The effect was hitherto unsuspected in physics, appears to be responsible for both the cosmological acceleration and the Pioneer 10/11 anomaly, and is exhibited in audio data. This paper discusses how it may be exploited for instant, passive ranging of signal sources, for verification, rescue and navigation; incoherent aperture synthesis for smaller, yet more accurate radars; universal immunity to jamming or interference; and precision frequency scaling of ...
Fusion device produces high-level neutrons and #gamma#-rays, which would hazard the safety of the public and workers if the doses would be higher than the regulatory limits because of leakage from the bio-shielding and skyshine. It is essential to monitor the radiation doses in the workshop and the enumerative around fusion devices. A radiation monitoring system (RMS) for full (near and far) areas around a nuclear fusion device has been designed and developed, which can achieve the monitoring and controlling of radiation doses in the workshop area by using the Controller Area Network (CAN), in the institution area by using the Bluetooth Ad hoc network based on a new tree topology formation and routing protocol and in a long range environment by using the General Packet Radio Service (GPRS) network. (authors)
Identifying gear damage categories, especially for early faults and combined faults, is a challenging task in gear fault diagnosis. This paper proposes a new multidimensional hybrid intelligent diagnosis method to identify different categories and levels of gear damage automatically. In this method, Hilbert transform, wavelet packet transform (WPT) and empirical mode decomposition (EMD) are performed on gear vibration signals to extract additional fault characteristic information. Then, multidimensional feature sets including time-domain, frequency-domain and time-frequency-domain features are generated to reveal gear health conditions. Multiple classifiers based on several classification algorithms and input features are combined with genetic algorithm (GA). Because of the use of multidim...
When gear fault occurs, the vibration signals always display non-stationary behavior. Therefore time-frequency analysis has become the well-accepted technique for vibration-based gear fault diagnosis. This paper presents the application of a new time-frequency signal processing technique, the Hilbert spectrum based on the maximal overlap discrete wavelet packet transform (MODWPT), to the analysis of simulation signals and gear fault vibration signals measured by the acceleration sensor fixed on the bearing house. As long as the decomposition scale and disjoint dyadic decomposition are chosen suitably, the original signal could be decomposed into a set of monocomponent signals whose instantaneous amplitude and instantaneous frequency own physical meaning. After the instantaneous amplitude a...
Network tomography aims at inferring internal network characteristics based on measurements at the edge of the network. In loss tomography, in particular, the characteristic of interest is the loss rate of individual links. There is a significant body of work dedicated to this problem using multicast and/or unicast end-to-end probes. Independently, recent advances in network coding have shown that there are several advantages from allowing intermediate nodes to process and combine, in addition to just forward, packets. In this paper, we pose the problem of loss tomography in networks that have network coding capabilities. We design a framework for estimating link loss rates, which leverages network coding capabilities and we show that it improves several aspects of tomography, including the identifiability of links, the tradeoff between estimation accuracy and bandwidth efficiency, and the complexity of probe path selection. We discuss the cases of inferring: the ...
Since 1985 the operating sections of the 1200 kV AC Ekibastuz-Urals transmission system were used for a variety of field studies on a wide range of technological problems associated to high voltage transmission lines. The tests performed confirmed correctness of the main engineering and design decision made at development stage and demonstrated that such transmission lines are reliable and efficient. 3 figs.
To determine the transient response of linear and time-invariant transmission systems which are only described for discret frequencies, it is possible to find a good functional approximation by means of the generalized impulse method, combined with the most important natural spline-interpolation functions of the first and the third degree. This procedure has been applied to calculate the step response of the transient behaviour of the zero-sequence impedance system of the high voltage transmission line.
Due to biological effects of magnetic fields of high voltage transmission lines and induced effects on has pipe line, telecommunication system and interference with sensitive electronic equipment, many effort have been done to reduce transmission lines magnetic fields and several ideas have been introduced. In this paper we review three methods: phase split, shielded and compacted line methods. With aid of a developed software programme these methods are then applied to transmission lines and the results are analyzed.
In this paper, research on pass schedule of tandem cold mill (TCM) is carried out. According to load (reduction, rolling force, motor power) balance, non-linear equations set with variables of inter-stand thickness is constructed. The pass schedule optimization is carried out by solving the non-linear equations set. As the traditional method, the Newton-Raphson method is used for solving the non-linear equations set. In this paper a new simple method is brought up. On basis of the monotone relations between thickness and load, the inter-stands thickness is adjusted dynamically. The solution of non-linear equations set can be converged by iterative calculation. This method can avoid the derivative calculation used by traditional method. So, this method is simple and calculation speed is high. It is suitable for on-line control. (author)
In this paper, research on pass schedule of tandem cold mill (TCM) is carried out. According to load (reduction, rolling force, motor power) balance, non-linear equations set with variables of inter-stand thickness is constructed. The pass schedule optimization is carried out by solving the non-linear equations set. As the traditional method, the Newton-Raphson method is used for solving the non-linear equations set. In this paper a new simple method is brought up. On basis of the monotone relations between thickness and load, the inter-stands thickness is adjusted dynamically. The solution of non-linear equations set can be converged by iterative calculation. This method can avoid the derivative calculation used by traditional method. So, this method is simple and calculation speed is high. It is suitable for on-line control. (author)
In this paper we present a model and simulator for many clusters of heterogeneous PCs belonging to a local network. These clusters are assumed to be connected to each other through a global network and each cluster is managed via a local scheduler which is shared by many users. We validate our simulator by comparing the experimental and analytical results of a M/M/4 queuing system. These studies indicate that the simulator is consistent. Next, we do the comparison with a real batch system and we obtain an average error of 10.5\\% for the response time and 12\\% for the makespan. We conclude that the simulator is realistic and well describes the behaviour of a large-scale system. Thus we can study the scheduling of our system called \\dirac in a high throughput context. We justify our decentralized, adaptive and opportunistic approach in comparison to a centralized approach in such a context.
This presentation focuses on the steps taken by the Westinghouse Hanford Company to meet an accelerated schedule for configuration and implementation of the MULTI LIMS in a multiple laboratory environment. The Westinghouse Hanford Company purchased the MULTI LIMS Laboratory Information Management System in August, 1993. Hardware delivery began in October, 1993. Less than four months later, the initial configuration was released for use in two Westinghouse Hanford Company laboratories. Several major obstacles were overcome during implementation. These include information gathering for base table loading, user training, acceptance of the new system by users of a legacy system, and hardware configuration issues. In summary, steps needed to be taken to meet the accelerated implementation schedule of the MULTI LIMS at the Hanford Site. The obstacles faced were overcome through the in-depth knowledge and help of the vendor and the dedication and ...
As an interim report on the study on vibration of transmission lines when gust is blowing, this paper introduces events of confused and other contacts between transmission lines, photographing of transmission line vibration, physical measurement on transmission line response, and development of simulation software. Events of confused contacts of high-voltage transmission lines with overhead ground wires have the following common conditions: gust blows nearly perpendicularly to the line direction; no obstacles exist in upwind directions; the wind blows upward or downward against high-voltage transmission lines; and size of the high-voltage transmission lines is 25 mm{sup 2}. According to photographs of transmission line vibration, it appears that gust caused a high-voltage transmission line on the ...
An Eulerian/Langrangian model was developed to study the two-phase flow in a two-dimensional, axisymmetric, direct-injection diesel engine, under motored and firing conditions. The liquid phase was tracked in a Lagrangian sense using discrete droplet packets (DDP). The gaseous phase was solved using an implicit, iterative, finite-difference, scheme of the control volume variety. Gaseous-phase turbulence was modeled using a compressible two-equation k/epsilon model. Turbulence effects on the liquid phase were modeled by superimposing a randomly oriented turbulent eddy velocity proportional to the root of the turbulent kinetic energy, on each packet's mean relative velocity. Droplet-droplet interactions were neglected. The general knowledge obtained during validation studies, was used to simulate the direct-injection two-stroke diesel engine under motored conditions. The simulation showed that by beginning of the injection, (15/sup 0/ ...
Tension pneumothorax in newborns is a rare but life-threatening complication. We encountered a case of a full-term neonate with a breech presentation. An elective cesarean section was scheduled. Immediately...Full Text Available
The project is currently on schedule. The design review meeting was held on 08/26/97 at the Coastal Systems Station in Panama City, Florida. The mechanical arrangement, performance analysis and design features were presented at the review meeting. A numbe...
The Subseabed Disposal Program has recently completed a 30-day, 0.286-scale laboratory simulation of an In Situ Heat Transfer Experiment (ISHTE), scheduled for eventual deployment in the deep ocean 600 nautical miles north of Hawaii. 10 figures.
The Subseabed Disposal Program has recently completed a 30-day, 0.286-scale laboratory simulation of an In Situ Heat Transfer Experiment (ISHTE), scheduled for eventual deployment in the deep ocean 600 nautical miles north of Hawaii. 10 figures.
Sears for the Kenmore PRO to schedule a free repair. Consumers can continue to use the cooktop (top burners) and the broiler as well as any clock and/or timer functions. Consumer...
An 82-year-old female, with left femoral neck fracture was scheduled for left hip hemiarthroplasty, under spinal anaesthesia. She had been suffering from diabetes, hypertension, lung cancer and was...Full Text Available
Operant conditioning techniques were applied to the study of how target fixations are controlled by the probability of signal occurrence. In a standard vigilance setting, gaze at three illuminable...Full Text Available
subject to a learning curve which should help to lessen the user's time at KSC. An MMSE Payload Handling Fixture has ...... (F4.I ASSlUN IASILlM.ny.CTC I ...
The Secure Automated Fabrication (SAF) line, an automated and remotely controlled manufacturing process, is scheduled for startup in 1987 and will produce mixed uranium/plutonium oxide fuel pins for the Fast Flux Test Facility (FFTF). The application of robotics in the fuel fabrication and supporting operations is described.
Scheduling is a stochastic process performed by production rules. In .... activated, which causes the available goal queue size to be exceeded, then the first goal to ...... when in doubt turn toward the terminal or when in doubt go ...
This workshop covered the latest practical engineering and operational management applications and techniques that have been found to enhance operational costs, reliability, and flexibility, with topics such as establishing the optimal refrigeration design cycle and operating design points; utility management; manpower scheduling; plant control philosophy and automation; short and long term maintenance scheduling; refrigerant loss detection and control; system contamination; component reliability; and equipment technical performance issues.
In this paper we consider the general, no-wait and no-idle permutation flowshop scheduling problem with deteriorating jobs, i.e., jobs whose processing times are increasing functions of their starting times. We assume a linear deterioration function with identical increasing rates for all the jobs and there are some dominating relationships between the machines. We show that the problems to minimize the makespan and the total completion time remain polynomially solvable when deterioration is considered, although these problems are more complicated than their classical counterparts without deterioration.
This paper experimentally evaluates the effects of applying autonomic management to the scheduling of maintenance operations in a deployed Chord network, for various membership churn and workload patterns. Two versions of an autonomic management policy were compared with a static configuration. The autonomic policies varied with respect to the aggressiveness with which they responded to peer access error rates and to wasted maintenance operations. In most experiments, significant improvements due to autonomic management were observed in the performance of routing operations and the quantity of data transmitted between network members. Of the autonomic policies, the more aggressive version gave slightly better results.
The subject of the 5th challenge proposed by the French Society of Operations Research and Decision Analysis (ROADEF) consists in scheduling technicians and interventions for telecommunications (http://www.g-scop.inpg.fr/ChallengeROADEF2007/ or http://www.roadef.org/). We detail the algorithm we proposed for this challenge which is a Greedy Randomized Adaptative Search Procedure (GRASP). Computational results led us to the 1st position in the Junior category and to the 4th position in All category of the Challenge ROADEF 2007.
BackgroundPlasmodium falciparum morbid and fatal risks are considerably higher in areas supporting parasite prevalence ≥25%, when compared with low transmission...Full Text Available
A community health survey of 438 individuals was taken to detect health problems related to high voltage electrical transmission among an adjacent residential population. Results revealed no significant...Full Text Available
OBJECTIVES: To reassess the risk of leukaemia associated with residential exposure near high voltage transmission electric lines of 49 kV and above in view of the recent publications. METHODS: Through...Full Text Available
A mollusciciding campaign was begun in Cul-de-Sac Valley, St Lucia, at the end of 1970, following several years of epidemiological studies in which transmission of Schistosoma mansoni...Full Text Available
To gain insight into the process of mitochondrial transmission in yeast, we directly labeled mitochondrial proteins and mitochondrial DNA (mtDNA) and observed their fate after the fusion of two cells....Full Text Available
This dissertation presents the development of the novel mechanical testing technique of in situ nanoindentation in a transmission electron microscope (TEM). This technique makes it possible to simultaneously observe and quantify the mechanical behavior of nano-scale volumes of solids.
The transmissible gastroenteritis coronavirus (TGEV) infects the epithelial cells of the intestinal tract of pigs, resulting in a high mortality rate in piglets. This study shows the interaction of...Full Text Available
AIM: To examine the determinants of maternal-neonatal transmission of hepatitis B virus (HBV).METHODS: A nested case-control study was conducted in Changsha, Hunan, People’s Republic...Full Text Available
Overhead, high power transmission lines have secured rights of way on agricultural lands in Minnesota. The economic impact of such utility crossings, including effects on land price, was investigated. Sale records and survey data were analyzed. Buyers, sellers, and brokers were interviewed concerning inconvenience, radio interference, appearance, and loss of irrigation possibilities due to the transmission lines. In nine affected sales, there was only one case in which less money was indicated for the farm because of the presence of a transmission line.
Overhead, high power transmission lines have secured rights of way on agricultural lands in Minnesota. The economic impact of such utility crossings, including effects on land price, was investigated. Sale records and survey data were analyzed. Buyers, sellers, and brokers were interviewed concerning inconvenience, radio interference, appearance, and loss of irrigation possibilities due to the transmission lines. In nine affected sales, there was only one case in which less money was indicated for the farm because of the presence of a transmission line.
The Conawapa-Winnipeg Power Transmission Complex includes five interrelated transmission and conversion facilities. This booklet describes work done on the upgrade of the southern receiver system, one component of the complex. The southern receiver system is composed of a network of high voltage transmission lines and station facilities. The booklet includes a description of the upgrade, the project setting, short and long-term effects and impact management, and the next steps to be taken in the process, including the regulatory process and public consultation.
With the increasing use of high voltage alternating current (HVAC) transmission lines there is a growing concern among the public about possible human health effects resulting from exposure to the electric fields associated with these lines. While there is no definitive evidence of such effects, mounting public fear and activism over hypothesized health risks is already causing delays in the licensing and constuction of major power transmission facilities, and is encouraging the formation of regulatory policy. This paper briefly reviews the concerns, biological effects data and standards for HVAC transmission lines.
Transmissions of sperm by unirradiated and irradiated cotton bollworm, Helicoverpa armigera, were studied by live dissection of females immediately after the initiation of mating. In cotton bollworm the sperm transfer was rather a complex process. In fact unirradiated males failed to transfer sperm in about 19% of their matings. When irradiated with 250 Gy and 400 Gy, aberrations of sperm transmission were about 21% and 50% respectively. The failure of spermatophore 'cap' location was an important reason of sperm transmission aberrations. When females mated to high-dose-irradiated males, their oviposition response appeared abnormal
An improved method to design suitable compensating schemes for extra high voltage transmission lines is presented. The technique is general and effective and will greatly facilitate the design of the optimal compensation scheme for extra high voltage transmission lines. The technique is illustrated for a typical 500 kV system. The equations developed here for voltage maxima and minima along the transmission line eliminate the need for point-to-point computation of the voltage profile. The controversy existing in the literature over the problem of making a choice between pi and tee configurations has been removed and it is established with a mathematical proof that the tee configuration requires compensating elements of lower ratings.
The mutual inductance between parallel transmission lines influences the locating of the transmission line faults. A fault location algorithm for parallel lines developed in this paper takes into account the magnetic coupling between parallel lines. The paper presents a detailed description of the developed algorithm and test results performed on a simplified real transmission line. The obtained error is less than 0.5 percent in most cases. Also, the developed algorithm is not sensitive to typical fault parameters, such as: resistance, type, location, and incidence angle. 7 refs, 4 figs, 12 tabs
Silicone-rubber washers function as damping and articulating elements in cast-aluminum spacers that separate bundle subconductors in each phase of extra-high-voltage transmission lines. Spacer/dampers are located every 3 ft. along transmission lines on Canada's first operational 500 and 735 kV system.
A study of the 150-300 keV proton beam transmission through glass (borosilicate) tapered capillaries with different diameters of the input and output of the capillary was performed. The focusing effect was observed. The areal density of the transmitted beam is enhanced by approximately 20 times. It was shown that changing a taper angle from 0.5 deg to 1.7 deg evidences the increase of the transmission coefficient more than by 300 times keeping the initial energy spectrum of ions. (author)
The audible noise produced by corona on high-voltage transmission lines has several characteristics that differentiate it from other community noises. Transmission line noise is quite broadband and has a significant high frequency content. Special instrumentation designed to measure this type of noise pollution is described. All measuring systems have the same three basic elements: a transducer, a processing device, and an output device. Recorders, microphone devices, frequency analyzers, and meteorological instrumentation are discussed.
The prediction of faults on high voltage transmission lines requires the detection of incipient faults, which is implemented by detection of the radio noise due to contaminated insulators, insulation deterioration, and improver connections. It is shown that the radio noise due to incipient faults is separable and identifiable from normal transmission line radio noise, hence faults can be predicted.
This paper presents some results of lightning induced over voltages for a typical high voltage transmission line configuration. The authors developed an elaborated electromagnetic coupling between the lightning channel and characteristics and the resulting induced overvoltage. The lightning current parameters, for local data, in order to determine the occurrence severity for high voltage transmission lines. (author)
Two dimensional Fourier spectra of near-infrared images of galaxies provide a powerful diagnostic tool for the detection of spiral arm modulation in stellar disks. Spiral arm modulation may be understood in terms of interference patterns of outgoing and incoming density wave packets or modes. The brightness along a spiral arm will be increased where two wave crests meet and constructively interfere, but will be decreased where a wave crest and a wave trough destructively interfere. Spiral arm modulation has hitherto only been detected in grand design spirals (such as Messier 81). Spiral arm amplitude variations have the potential to become a powerful constraint for the study of galactic dynamics. We illustrate our method in two galaxies: NGC 4062 and NGC 5248. In both cases, we have detected trailing and leading m=2 waves with similar pitch angles. This suggests that the amplification mechanism is the WASER type II. In this mechanism, the bulge region reflects ...
Because of the stochastic nature of traffic requirement matrix, it is very difficult to get the optimal traffic distribution to minimize the delay even with adaptive routing protocol in a fixed connection network where capacity already defined for each link. Hence there is a requirement to define such a method, which could generate the optimal solution very quickly and efficiently. This paper presenting a new concept to provide the adaptive optimal traffic distribution for dynamic condition of traffic matrix using nature based intelligence methods. With the defined load and fixed capacity of links, average delay for packet has minimized with various variations of evolutionary programming and particle swarm optimization. Comparative study has given over their performance in terms of converging speed. Universal approximation capability, the key feature of feed forward neural network has applied to predict the flow distribution on each link to minimize the average ...
We will report on a new type of tunable semiconductor laser, which is based on the electronic selection of one Bragg grating among an array of such gratings in silica. The device that we have built operates at 120 Mb/s but extension to 1 Gb/s for Gigabit-Ethernet applications would be straightforward. In comparison with tunable semiconductor lasers using gratings in the III-V materials, silica gratings offer two significant advantages: 1-wavelength stability and predictability, 2-the ability to phusically overlap many gratings in a compact space in order to enable the selection of a large number of wavelengths for wavelength division multiplexed communications systems. The time required to chagne the wavelength in our laser has not been measured for lack of the necessary electronics but it is expected to be in the microsecond range on the basis of a straightforward calculation. The robust all solid-state nature of our device and its expected microsecond random-access tuning capability ...
The SCILS program investigates and demonstrates concepts of operation for dispersed theater forces C3. The dispersal concept would increase the number of potential targets for nuclear strike, make these targets smaller, more highly mobile and harder to find, and introduce functional redundancy. The SCILS system is a microcomputer-based approach to preserving and enhancing the effectiveness of C3 operation in a dispersed configuration. In this program, the system was implemented for testing for the 9th Infantry Division in coordination with the Army's Distributed Command and Control System. Technical highlights of the system include a distributed, replicated data base, a video map/graphics-oriented Commander's Decision Display System, a packet switched Multi-Media Network that operates with deployed field communication systems, and a Voice/Data Conferencing System that supports remote coordination/briefing in a dispersed configuration. The program ...
An attempt is made to generalize the spaces of numbers and functions in order to consider certain problems in quantum mechanics, especially in the cases, where wave functions appear which do not belong to the Hilbert space L"2. Often the Soboljev - Schwartz distributions are used but they are not always the appropriate tool because they cannot be multiplied. A modification of the definition of generalized functions PSI(x vector) is proposed by particular conditions. Such conditions imposed on the wave function of a free particle seems to be the most natural by means of physics. It appears, however, that for all spaces with a real norm these conditions are contradictory. This implies together with the extension of the space of functions, an extension of the space of numbers with so called asymptotic numbers A. The four algebraic operations - addition, subtraction, multiplication and division are defined in the set A. To avoid the contradictions between the conditions it is necessary to ...
Although the current Internet Protocol known as IPv4 has served its purpose for over 20 years, its days are numbered. With IPv6 reaching a mature enough level, there is a need to evaluate the performance benefits or drawbacks that the new IPv6 protocol will have in comparison to the well established IPv4 protocol. Theoretically, the overhead between the two different protocols should be directly proportional to the difference in the packet's header size, however according to our findings, the empirical performance difference between IPv4 and IPv6, especially when the transition mechanisms are taken into consideration, is much larger than anticipated. We first examine the performance of each protocol independently. We then examined two transition mechanisms which perform the encapsulation at various points in the network: host-to-host and router-to-router (tunneling). Our experiments were conducted using two dual stack (IPv4/IPv6) routers using end nodes running ...
This document is the third annual revision of the plans and schedules for implementing the Federal Facility Agreement (FFA) compliance program, originally submitted in 1992 as ES/ER-17&D1, Federal Facility Agreement Plans and Schedules for Liquid Low-Level Radioactive Waste Tank Systems at Oak Ridge National Laboratory, Oak Ridge, Tennessee. This document summarizes the progress that has been made to date in implementing the plans and schedules for meeting the FFA commitments for the Liquid Low-Level Waste (LLLW) System at Oak Ridge National Laboratory (ORNL). Information presented in this document provides a comprehensive summary to facilitate understanding of the FFA compliance program for LLLW tank systems and to present plans and schedules associated with remediation, through the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) process, of LLLW tank systems that ...
The Superfund Amendments and Reauthorization Act of the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) requires a Federal Facility Agreement (FFA) for federal facilities placed on the National Priorities List. The Oak Ridge Reservation was placed on that list on December 21, 1989, and the agreement was signed in November 1991 by the Department of Energy Oak Ridge Field Office (DOE-OR), the US Environmental Protection Agency (EPA)-Region IV, and the Tennessee Department of Environment and Conservation (TDEC). The effective date of the FFA was January 1, 1992. Section 9 and Appendix F of the agreement impose design and operating requirements on the Oak Ridge National Laboratory (ORNL) liquid low-level radioactive waste (LLLW) tank systems and identify several plans, schedules, and assessments that must be submitted to EPA/TDEC for review or approval. The initial issue of this document in March 1992 transmitted to EPA/TDEC those plans ...
Combination of radiotherapy and chemotherapy (CRC) is actually one important way of research in oncology. Theoretical advantages are: (1) Spatial cooperation; (2) Additivity, which is only obtained if the toxicity of each modality are different; (3) Supra-additivity, which needs a rigorous in vitro definition; the only way to prove it is to make an isobologram analysis. This model has however, some limitations: qualitative variable could not be used, results could be different, depending on the cell line and isoeffect chosen...In fact, a supra-additivity was only demonstrated for cis platinum and etoposide. Interactions mechanisms were: (1) at the molecular level, creation of new lesions or inhibition of radiation lesions repair; (2) At the cellular level, either cytokinetic cooperation with S-phase dependent drugs, or synchronization for the drugs which blocked the cells in M-phase; (3) At the tissular level, reoxygenation, cycle redistribution. In clinical practice, three main ...
Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmission line voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmission line conductors. Transmission line noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmission lines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, corona radio noise varies significantly with the weather and atmospheric conditions ...
Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmission line voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmission line conductors. Transmission line noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmission lines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, corona radio noise varies significantly with the weather and atmospheric conditions ...
Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmission line voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmission line conductors. Transmission line noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmission lines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, corona radio noise varies significantly with the weather and atmospheric conditions ...
Wheeling electric power, the transmission of electricity not owned by an electric utility over its transmission lines, is a term not generally recognized outside the electric utility industry. Investigation of the term`s origin is intriguing. For centuries, wheel has been used to describe an entire machine, not just individual wheels within a machine. Thus we have waterwheel, spinning wheel, potter`s wheel and, for an automobile, wheels. Wheel as a verb connotes transmission or modification of forces and motion in machinery. With the advent of an understanding of electricity, use of the word wheel was extended to be transmission of electric power as well as mechanical power. Today, use of the term wheeling electric power is restricted to utility transmission of power that it doesn`t own. Cogeneration refers to simultaneous production of electric and thermal power from an energy ...
The magnitude of electric and magnetic fields around a high voltage three-phase transmission line was studied. A three-phase transmission circuit with parallel conductors produces rotating elliptic electric and magnetic fields. This study investigated the optimum arrangement of the phase conductors to minimize the maximum value of the magnetic flux density and to minimize the intensity of the resultant electric field. Two different types of high voltage double circuit transmission lines of 400 kV were considered. The optimum arrangement of the phase conductors was determined. It was concluded that the optimum arrangement can be easily applied to already constructed high voltage transmission lines by properly interchanging the phase conductors at the substations. 10 refs., 1 tab., 4 figs.
The magnitude of electric and magnetic fields around a high voltage three-phase transmission line was studied. A three-phase transmission circuit with parallel conductors produces rotating elliptic electric and magnetic fields. This study investigated the optimum arrangement of the phase conductors to minimize the maximum value of the magnetic flux density and to minimize the intensity of the resultant electric field. Two different types of high voltage double circuit transmission lines of 400 kV were considered. The optimum arrangement of the phase conductors was determined. It was concluded that the optimum arrangement can be easily applied to already constructed high voltage transmission lines by properly interchanging the phase conductors at the substations. 10 refs., 1 tab., 4 figs.
During the early 1970s, controversy developed over the possible biological effects of electric fields from new 500-kilovolt and 765-kilovolt transmission lines. This, along with growing interest in advancing transmission voltage into the ultrahigh-voltage range (1000 kilovolts and above), led to the initiation of numerous research projects. Several reviews of this research by scientists in the US and other countries indicate that transmission lines have not been proven to be a health hazard to people or animals. The issue remains controversial, however, because research has confirmed some subtle effects of electric fields, and because it is an inseparable part of the public opposition that often accompanies the siting of high-voltage transmission lines. In addition, there is renewed interest in magnetic fields, including a possible association between such fields and human cancers. 2 figures, 2 tables.
The invention is a mechanism for retaining an electrical transmission line. In one embodiment of the invention it is a system for retaining an electrical transmission line within downhole components. The invention allows a transmission line to be attached to the internal diameter of drilling components that have a substantially uniform drilling diameter. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string, drill collars, heavy weight drill pipe, and jars. The system also includes a coaxial cable running between the first and second end of a drill pipe, the coaxial cable having a conductive tube and a conductive core within it. The invention allows the electrical transmission line to withstand the tension and compression of drill pipe during routine drilling cycles.
Various initiatives have been undertaken by the Federal Energy Regulatory Commission (FERC) to deregulate wholesale electric energy markets. These initiatives have focused on restructuring the transmission systems in the US and recently have culminated in a proposal requiring formation of and participation in regional transmission organizations. The overall form of regulation selected to determine rates for transmission entities as well as underlying regulatory decisions reached on key issues will have profound implications for transmission entities. For example, traditional cost-based regulation would require one set of accounting and reporting rules, while incentive-based regulation may not be subject to those same rules. An overview of some of the major accounting and financial reporting issues that will need to be considered is presented.
This paper presents a Benders decomposition approach to determine the optimal day-ahead power scheduling in a pool-organized power system, taking into account dispatch, network and security constraints. The study model considers the daily market and the technical constraints resolution as two different and consecutive processes. The daily market is solved in a first stage subject to economical criteria exclusively and then, the constraints solution algorithm is applied to this initial dispatch through the redispatching method. The Benders partitioning algorithm is applied to this constraints solution process to obtain an optimal secure power scheduling. The constraints solution includes a full AC network and security model to incorporate voltages magnitudes as they are a critical factor in some real power systems. The algorithm determines the active power committed to each generator so as to minimize the energy redispatch cost subject to ...
This paper presents a new approach for solving multistage decision problems in power system operation by using a new fuzzy dynamic programming technique. To investigate its validity, the hydrothermal scheduling problem is used as an example problem. Within this problem, uncertainty elements exist such as load demand and natural hydraulic inflows to reservoirs exist which can be expressed by fuzzy numbers. Two new fuzzy decision making techniques for selecting the optimal operating states at each stage are introduced. Further, the hydrothermal scheduling solution obtained had an operating band defined by upper and lower bounds. To further enhance the information that this operating band provides, a midpoint operation technique that applies both forward and backward fuzzy DP is also introduced. This allows the system operator to consider current operating conditions to determine a suitable stage by stage operation policy within the bounds of the ...
All of the project work since the previous report has been on Phase 2B tasks. Therefore, this quarterly progress report summarizes the period's activities in Engineering, Procurement and Civil Construction. Engineering is 95% complete, but revisions and changes are still being incorporated particularly in the Instrument and Electrical areas. Procurement has only valves 4 in. and above yet to order to complete all major items purchased. The scheduled material curve was based on the original estimate of the job. The projected curve reflects the previous month's estimate. Construction of civil work is proceeding according to schedule in the field. The initial bid packages for the Mechanical General Contractor portion of the work have been reviewed and evaluated. Order placement is scheduled for the end of July. The Electrical package is due back from the bidders on July 6. It requires additional evaluation by ...
Summary Purpose BMS-275183 is an oral C-4 methyl carbonate analogue of paclitaxel that has the same mechanism of action, stabilization of tubulin polymerization. The present study was designed to: (i) assess the safety and tolerability of BMS-275183, and (ii) determine a suitable Phase II dose of BMS-275183 when given on a continuous daily schedule to patients with advanced solid tumor(s). Methods This was a multi-institutional, open-label, Phase I, single-arm dose escalation study in which cohorts of eligible patients with advanced malignancies were treated with BMS-275183 orally on a continuous daily schedule. The starting dose level was 6?mg/m2/day administered once daily. Cohorts of 3 patients were treated at each dose level provided no dose-limiting toxicities (DLTs) were observed. Ea...
The U.S. Department of Energy (DOE) Headquarters and associated contractors have developed an IBM PC-based software package that estimates costs, schedules, and public and occupational health risks for a range of mixed-waste management options. A key application of the software package is the comparison of various waste-treatment options documented in the draft Site Treatment Plans prepared in accordance with the requirements of the Federal Facility Compliance Act of 1992. This automated Systems Analysis Methodology consists of a user interface for configuring complexwide or site-specific waste-management options; calculational algorithms for cost, schedule and risk; and user-selected graphical or tabular output of results. The mixed-waste management activities modeled in the automated Systems Analysis Methodology include waste storage, characterization, handling, transportation, treatment, and disposal. Analyses of treatment options identified ...
The ALICE experimental area management team faces various challenges when it comes to sharing scarce resources, indispensable to any efficient installation in a category one worksite. Space, cranes, jigs, and personnel with key competences have to be carefully allocated to activities so as to avoid slowing down work progress. To this intent, a resource loaded planning has been developed that allows highlighting coactivities and prioritizing critical tasks. It uses the built-in capabilities of Microsoft Project. The use of this scheduling tool leads to a more efficient use of time and a safer work environment. The installation sequence resulting from this schedule is presented in this paper. The first part of the sequence focuses on the revision of the coils in the SX2 building. The dipole has then to be installed in the RB26 side of the UX25 cavern. This complex and resource intensive activity has to be performed in parallel with the services ...
A programme to optimize the short-term operation planning of hydrothermal system scheduling is presented. Based on heuristics, an operational planning of pumped storage plants and a method for fast evaluations of spot market deals under consideration of load forecast errors was developed. (orig.) [German] Vorgestellt wird ein Programm, das - basierend auf Heuristiken - den kurzfristigen Einsatz eines hydrothermischen Kraftwerksparks optimiert. Im Programm wurde dazu ein Verfahren zur Pumpseichereinsatzplanung und zur sekundenschnellen Bewertung von Spot-Markt-Geschaeften unter Beruecksichtigung von Lastprognosefehlern entwickelt. (orig.)
The Real-Time Specification for Java (RTSJ) is silent on multiprocessor issues. It attempts not to preclude multiprocessor implementations but provides no direct support. Many areas of the RTSJ leave an implementation considerable freedom on how it provides the defined functionality. One such area is the asynchronous event handling (AEH) model. Events are fired and associated handlers are scheduled for execution in response; handlers have defined scheduling parameters and deadlines. The primary goal of the AEH model is to support a lightweight real-time concurrency model. Hence handlers, in general, do not have dedicated threads. Rather, the implementation is responsible for ensuring that all handlers meet their deadlines. Typically real-time threads are assigned to execute handlers by the...
Variability in production is one of the largest factors that negatively impacts construction project performance. A common construction practice to protect production systems from variability is the use of buffers (Bf). Construction practitioners and researchers have proposed buffering approaches for different production situations, but these approaches have faced practical limitations in their application. A multiobjective analytic model (MAM) is proposed to develop a graphical solution for the design of Work-In-Process (WIP) Bf in order to overcome these practical limitations to Bf application, being demonstrated through the scheduling of repetitive building projects. Multiobjective analytic modeling is based on Simulation?Optimization (SO) modeling and Pareto Fronts concepts. Simulation...
Work on the coke oven gas cleaning demonstration project (CCT-11) this quarter has focused on Phase IIB tasks, and include engineering, construction, and training. Additionally, plans for changes in the operating schedule of the coke plant that affect the demonstration project are described. The project Milestone Schedule and Log is shown. Planned Baseline Supplemental Monitoring activities described in the Environmental Monitoring Plan were completed. Testing of the mechanical systems began in June, 1991. The cold commissioning date has been moved back from October 1, 1991 to November 1, 1991 to allow float for miscellaneous finish-up items beyond the electrical contractor`s projected completion date of October 31, 1991.
Modern scientific computing involves organizing, moving, visualizing, and analyzing massive amounts of data from around the world, as well as employing large-scale computation. The distributed systems that solve large-scale problems will always involve aggregating and scheduling many resources. Data must be located and staged, cache and network capacity must be available at the same time as computing capacity, etc. Every aspect of such a system is dynamic: locating and scheduling resources, adapting running application systems to availability and congestion in the middleware and infrastructure, responding to human interaction, etc. The technologies, the middleware services, and the architectures that are used to build useful high-speed, wide area distributed systems, constitute the field of data intensive computing. This paper explores some of the history and future directions of that field.
Excessive physical activity plays an important role in the progression of anorexia nervosa (AN) by accelerating weight loss during dietary restriction. To search for mechanisms underlying this trait, a panel of mouse chromosome substitution strains derived from C57BL/6J and A/J strains was exposed to a scheduled feeding paradigm and to voluntary running wheel (RW) access. Here, we showed that A/J chromosomes 4, 12 and 13 contribute to the development of a disrupted RW activity in response to daily restricted feeding. This pattern is characterized by intense RW activity during the habitual rest phase and leads to accelerated body weight loss. Regions on mouse chromosomes 4, 12 and 13 display homology with regions on human chromosomes linked with anxiety and obsessionality in AN cohorts. The...
This paper reports on hydroelectric pumped storage which is the only proven and most efficient technology available for energy storage. It is used by utilities to provide peak and intermediate power and to optimize overall system performance. Because of increased environmental and regulatory constraints, few acceptable sites, long schedules, and huge financial commitments, large conventional pumped storage plants, are now virtually impossible to build. As an alternative, small modular pumped storage, with project sizes ranging from 25 MW to 200 MW, was created to overcome the difficulties of conventional projects. The modular approach involves standardizing the elements of a pumped storage plant by utilizing specialized siting techniques and optimizing design, equipment, and construction. Compared with conventional pumped storage, the modular design can reduce cost and expedite schedule; reduce environmental concerns and permitting obstacles; ...
In this paper a new fuzzy decision-making procedure is developed. Two levels of weightings, called upper and lower weights, are proposed to calculate the fuzzy weightings of different criteria. The preference table is introduced to calculate the upper and lower weights. Also a new method is developed to determine the expected preference values of different alternatives. These values are used for generating the priority list of alternatives. The procedure is applied for providing an emergency electric power distribution, scheduling time table. The IEEE 14-bus standard system and a 14-bus system with four power plants are considered as case studies. Using fuzzy decision-making procedure, the regions with more priorities are more connected to the distribution net, while the maximum consumption criterion is also reasonably respected. (author)
The vigilance reinforcement hypothesis (VRH) asserts that errors in signal detection tasks are partially explained by operant reinforcement and extinction processes. VRH predictions were tested with a computerized baggage screening task. Our experiment evaluated the effects of signal schedule (extinction vs. variable interval 6 min) and visual field complexity (dial vs. baggage x-ray) on search behavior rates. There was a main effect for signal schedule [F (1, 20) = 14.0, p = 0.001, p[subscript rep] = 0.99], but no effects for field complexity or interaction. The VRH suggests that performance errors in visual screening work may be reduced through operant conditioning of search behaviors by intensive management of artificially planted signals. (Contains 1 table and 3 figures.)
It is well known that the lightning protection of transmission lines is exclusively relying on their correct initial design. Although detailed engineering studies are usually performed by electric power utilities for the design of new transmission lines, there are reported cases where the design is based simply on tradition or on utilities' standardization policy. In this paper, the lightning protection of high-voltage transmission lines is faced as an optimization problem where optimum design parameters are calculated for the lines, relating their cost with the lightning failures' cost, aiming to reduce or even eliminate lightning failures. The optimization method considers all the available protection means, i.e. ground wires and surge arresters. In order to validate the effectiveness of the proposed method, it is applied on several operating Hellenic transmission lines of 150 kV ...
Since 1994-95 the University of Applied Sciences Berne is working on weather-proof electric bicycles. The main drawbacks of bicycles, no weather-protection, little comfort of the saddle, the difficulty of climbing hills, are to be eliminated. The electro-mechanical drive-train of 'Ultraleichtmobil ULM BE 2000', developed in 1995-96, was mechanically complicated. This resulted in reduced energy-efficiency and intense maintenance. Too, the drive-train was expensive in production. A fully electrical human-power transmission seemed to be the solution to the problems mentioned above. It is appealing not only to the user of the vehicle, but also to the producer and to the persons doing the maintenance. Following an internal study showing the technical feasibility of such an electrical transmission, a controllable DC/DC-converter which allows to operate a pedal-driven generator at maximum efficiency has been developed. The electrical ...
A general calculation method for the analysis of transmission capability of a long-distance single-core ac submarine cable system is presented. The method is based on modal transformation of voltages and currents in multiconductor cable systems. Using this method, numerical calculations on 500 kV submarine cable systems have been performed with particular reference to the effect of the distance between bonds connecting metallic sheath, outer conductor and armor on the transmission capacity of the system. It was clarified that the transmission capacity of the system increased with decreasing bond intervals. Examination of the current distributions between various conductors along the length showed that this increase of transmission capacity was mainly due to the dispersion of the charging current into the metallic sheath, outer conductor and armoring at the bonding points. Analytical results for the ...
This paper examines why ship shaped floating production storage and offloading (FPSO) systems have been selected for the first two developments on Foinaven and Schiehallion fields in West of Shetland operated by BP Exploration. An overview of the concepts considered for the deepwater harsh environment is made against the business objectives and reservoir conditions which are the primary drivers behind development concept selection. Discussion of technical issues for a range of concepts are held on schedule, construction, installation, safety, flexibility to production throughput, capital and operating costs.
Volume four contains calculations for: Borrow areas--site evaluation; temporary facilities--material quantities; embankment quantities--excavation and cover materials; Burro Canyon site excavation quantities--rippable and unrippable materials; site restoration--earthwork quantities and seeding; and bid schedule quantities and material balance.
A 76-year-old, 148-cm woman was scheduled for right upper lobectomy. A 32 Fr left-sided double lumen tube was placed using a conventional technique. Despite several attempts under fiberoptic bronchoscope-guidance,...Full Text Available
BackgroundThe Plasmodium falciparum pre-erythrocytic stage candidate vaccine RTS,S is being developed for protection of young children against...Full Text Available
The principle for working out the time-temperature schedule of the carbonization was determined through the investigation on the carbonization process of the green body and the phenol formaldehyde resin. During the carbonization process, the crack at lower temperatures is due to strain inhomogeneity produced in press. But the crack at higher temperatures results from the improper increasing rate of temperature. The application of the autoclave-carbonization process can increase the mechanical properties of the spherical fuel elements.
The report presents an integrated software system developed at the Norwegian Electric Power Research Institute (EFI), for production scheduling, maintenance handling, network security analysis, inflow forecasting, and load forecasting. The integrated software is being developed with focus on hydro-dominated power supply systems. In specific terms it is expected that application of the software will improve the operational decisions, and make the planning process more effective. The optimal scheduling of hydro resources poses severe computational problems in system operations planning. This necessitates problem decomposition. In the EFI approach, planning is split into three main levels: long-term, mid-term and short-term planning. The long-term planning aims at evaluating the seasonal and pluriannual handling of regional storages in view of firm power supply obligations, inflow statistics, main hydraulic and electric transit limitations, and ...
During the first 18 months of this project, four experimental subtasks were to have begun but only one of these was to have been completed. Additionally, five modeling subtasks were scheduled to begin, four of which were to have been completed. We are on schedule for all but one of these subtasks. All four experimental tasks are progressing on schedule. Initial durability tests were completed. The conclusions drawn from this first round of durability tests are being used to design the next set of tests. Initial baseline engine data were acquired and showed that the engine selected for this task behaves as hoped. However, the dyno controller is inadequate. The engine will be moved to another dyno during the near future. The modeling tasks are also progressing well. A model for the dynamic response of the ignition circuit was developed and validated. Two technical papers resulting from this model were submitted for ...
A summary is provided of the first of three years of experimental and theoretical research on free-forced convection flows in cavity-type solar receivers. New experimental and theoretical results are presented and discussed. The implication of these findings, with respect to the future thrust of the research program, is clarified as well as is possible at the present time. Following various related conclusions a summary and tentative schedule of work projected for year two of research are presented.
This report is an Implementation Guide for Hanford Tanks Initiative C-106 heel retrieval contract management HNF-2511 to provide a set of uniform instructions for managing the two contractors selected. The primary objective is to produce the necessary deliverables and services for the HTI project within schedule and budget.
... (restricted)] 98-118 Oil prices and competitiveness: time series evidence from six oil-producing countries by Mohammad R. Jahan-Parvar & Hassan Mohammadi [Downloadable! (restricted)] 2008, Volume 35, Issue 6 444-485 The S-shaped labor supply schedule: evidence from industrialized countries by Maryke ...
This document, the Standards/Requirements Identification Document (S/RID) Phase 2 Assessment Report for the subject facility, represents the results of a Performance Assessment to determine whether procedures containing S/RID requirements are fully implemented by field personnel in the field. It contains a summary report and three attachments; an assessment schedule, performance objectives, and assessments for selected functional areas.
This document describes a simple and general way to generate House Simulation Protocol (HSP)-consistent internal sensible and latent loads in unoccupied homes. It is newly updated based on recent experience, and provides instructions on how to calculate and set up the operational profiles in unoccupied homes. The document is split into two sections: how to calculate the internal load magnitude and schedule, and then what tools and methods should be used to generate those internal loads to achieve research goals.
This document presents the details of the implementation of the Site Treatment Plan developed by Ames Laboratory in compliance with the Federal Facilities Compliance Act. Topics discussed in this document include: implementation of the plan; milestones; annual updates to the plan; inclusion of new waste streams; modifications of the plan; funding considerations; low-level mixed waste treatment plan and schedules; and TRU mixed waste streams.
... To participate in the live conference call, please dial the following number five to ten minutes prior to the scheduled conference call time:... International callers should dial +1 (706) 643-0585. When prompted by the operator, mention conference pass code 89461112. ... To access the replay, please dial +1 (855) 859-2056, international callers dial +1 (404) 537-3406, ...
The Project was started August 1, 1992. During these first two months, the Project Management plan was issued and approved during discussions at the Pittsburgh Energy and Technology Centre. Feed materials for the experimental work (with the exception of the second solvent) have been received. The analytical work up of these feed materials has been completed, and autoclave stability tests with the solvent and solvent fraction have been performed and analyzed. The Project is proceeding on schedule.
The Project was started August 1, 1992. During these first two months, the Project Management plan was issued and approved during discussions at the Pittsburgh Energy and Technology Centre. Feed materials for the experimental work (with the exception of the second solvent) have been received. The analytical work up of these feed materials has been completed, and autoclave stability tests with the solvent and solvent fraction have been performed and analyzed. The Project is proceeding on schedule.
This document contains responses and planned actions that address the findings of the Tiger Team Assessment of Brookhaven National Laboratory, June 1990. In addition, the document contains descriptions of the management and organizational structure to be used in conducting planned actions, root causes for the problems identified in the findings, responses, planned actions, schedules and milestones for completing planned actions, and, where known, costs associated with planned actions.
...prosthesis) Anatomical loss near hip (preventing use of prosthesis) Anatomical loss or loss of use below elbow M Codes M-1 a, b, or c, 38 CFR 3.350 (c)(1)(i) L Codes L-1 d, e, f, or g, 38 CFR 3.350(b)...
This document presents the proceedings of the Areva technical days, presented during the session 5 the 9 and 10 december 2004, at Istanbul. It deals with the operations of the transmission and distribution division. With manufacturing facilities in over 40 countries and a sales network in over 100, Areva offers customers technological solutions for nuclear power generation and electricity transmission and distribution (the Group also provides interconnect systems to the telecommunications, computer and automotive markets). It provides five topics: a general presentation of Areva, the strategic stakes for transmission and distribution by world-zone, economic and strategic stakes of business unit products, business unit systems and business unit automation. (A.L.B.)
Audible noise from corona discharge had been identified as one of the most important factors in the design of conductor configurations for high-voltage transmission lines. 500 kV and above. Therefore this paper describes audible noise characteristics of 6 X 480 mm{sup 2} conductor bundle in KEPRI 765 kV Test Line and Corona Cage. Prediction formula for audible(corona) noise on a 765 kV Transmission Line was developed using this results. (author). 4 refs., 4 figs., 4 tabs.
A computer-aided design procedure has been developed for the series compensation of an extra high voltage line with a compensating network connected at one or the other end or both ends. Higher degree polynomial equations are derived in terms of compensating elements to compute the network parameters for optimum received power with constrained capacitor terminal voltage, safe line current, Ferranti voltage and transient stability. It is shown that series capacitors located at both ends provide the most effective means from the viewpoint of power transmission capability in either direction, transmission efficiency and series capacitor rating in comparison with a capacitor located at one or the other end.
A detailed examination of the aging processes that may take place in solid-dielectric extruded-type high voltage transmission cables under dry conditions is presented. Particular emphasis is placed on the aging process as affected by the separate and simultaneous action of four main aging factors, namely the electrical, mechanical and thermal stresses, and the physical and chemical environment. A number of pertinent aging models are considered and their validity and applicability to accelerated aging tests on solid-type transmission cables are discussed.
High-voltage transmission lines can pose an environmental problem, especially in countries where the electricity production is at a distance from the demand location. Planning, construction, and operation of high voltage transmission lines should be conducted within a comprehensive environmental policy, which may include assessment of visual impact, landscape and wildlife protection, and reduction of health risks. This paper reviews the environmental policies and action in planning, construction, and operation as developed by the utilities members of the Union Internationale des Producteurs et Distributeurs d`Energie Electrique (UNIPEDE). The paper also presents a brief outline of the health issues associated with the effects of electromagnetic fields to humans.
High-voltage transmission lines can pose an environmental problem, especially in countries where the electricity production is at a distance from the demand location. Planning, construction, and operation of high voltage transmission lines should be conducted within a comprehensive environmental policy, which may include assessment of visual impact, landscape and wildlife protection, and reduction of health risks. This paper reviews the environmental policies and action in planning, construction, and operation as developed by the utilities members of the Union Internationale des Producteurs et Distributeurs d'Energie Electrique (UNIPEDE). The paper also presents a brief outline of the health issues associated with the effects of electromagnetic fields to humans.
Comparisons of the 60 Hz electric field exposures associated with high voltage transmission lines to those associated with common household sources can provide an important input to regulatory decisions that involve transmission line fields. Electric blankets are of interest in this context because the exposures they produce are among the most intense and prolonged of any of the household sources of 60 Hz electric field exposure. This paper presents a theoretical analysis of the body surface fields induced by electric blankets. Electric blanket exposure intensities are compared to those associated with transmission lines.
Construction of high voltage transmission lines in a difficult hilly terrain within the limited time frame calls for the adoption of modern management tools for controlling the progress. The activity on node network system for such works, in which parallel and overlapping activities are involved is highly useful and is being used in Himachal Pradesh State Electricity Board. This network system has helped the Board to provide an effective and efficient mode of progress reporting at all levels of functioning. A remarkable example is the control of construction of 190 km - 200 kV dc transmission line within four years and six months.
Renewable energy technologies such as photovoltaics, solar thermal power plants, and wind turbines are nonconventional, environmentally attractive sources of energy that can be considered for electric power generation. Many of the areas with abundant renewable energy resources (very sunny or windy areas) are far removed from major load centers. Although electrical power can be transmitted over long distances of many hundreds of miles through high-voltage transmission lines, power transmission systems often operate near their limits with little excess capacity for new generation sources. This study assesses the available capacity of transmission systems in designated abundant renewable energy resource regions and identifies the requirements for high-capacity plant integration in selected cases. In general, about 50 MW of power from renewable sources can be integrated into existing transmission systems to ...
... Microwaves, radio waves, and low-frequency electromagnetic fields from high-voltage transmission lines . Non-Methane Hydrocarbon (NMHC): The sum of all hydrocarbon air ...
A number of epidemiological studies indicate an association between depression and proximity to high voltage transmission lines. These studies have been criticized, however, for using surrogate measures of electromagnetic fields (EMFs) and unstandardized measures of depression. In an effort to overcome these limitations, the Center for Epidemiological Studies Depression (CES-D) scale was administered to 152 women living either adjacent to a transmission line or one block away. Results indicate that homes adjacent to the transmission lines have an average EMF level of 4.86 milligauss at their front door and those one block away have an average of 0.68 milligauss. There was no significant difference in CES-D scores between the groups, controlling for demographic variables. There appeared to be an increase in other health effects, including cancer and miscarriages, but these findings were preliminary and need further ...
An automotive powertrain includes a conventional piston engine, a continuously variable ratio transmission, an engine speed sensor and a feedback control system. The control system adjusts both the transmission ratio and the throttle valve in the engine carburetor or fuel metering system in response to the position of the accelerator pedal and in response to the crankshaft speed as measured by the engine sensor. The transmission provides extreme overdrive gear ratios which allow the engine to be operated at wide open throttle even during moderate cruising, and, in addition, the engine carburetor or fuel metering system is calibrated to deliver to the engine a stoichiometric air-fuel mixture which is combined, before combustion, with a special proportion of recirculated exhaust gas. As a result of extensive wide open throttle engine operation with the above mentioned intake charge composition, combustion variables are ...
We investigate opportunistic cooperation between unlicensed secondary users and legacy primary users in a cognitive radio network. Specifically, we consider a model of a cognitive network where a secondary user can cooperatively transmit with the primary user in order to improve the latter's effective transmission rate. In return, the secondary user gets more opportunities for transmitting its own data when the primary user is idle. This kind of interaction between the primary and secondary users is different from the traditional dynamic spectrum access model in which the secondary users try to avoid interfering with the primary users while seeking transmission opportunities on vacant primary channels. In our model, the secondary users need to balance the desire to cooperate more (to create more transmission opportunities) with the need for maintaining sufficient energy levels for their own ...
Schizophrenia is a heterogeneous psychiatric disorder in which multiple neurotransmitter systems have been implicated. Increased and decreased dopamine transmission in the subcortical meso-limbic and...Full Text Available
The company reports that with the help of outside companies, they completed all major fixes including high-voltage transmission lines to neighborhood ...
...Systems, UWA investigating rate uplift effects of shallow foundation systems associated with high voltage transmission line support towers. This work was funded by National Grid, ...
BACKGROUNDNew diagnostic tools are urgently needed to interrupt the transmission of tuberculosis and multidrug-resistant tuberculosis. Rapid,...Full Text Available
Abstract Voltage sag caused by faults on an electric power transmission line is one of the most intractable power quality issues for both utility companies and customers. The fault in power system randomly exists along transmission lines due to the combination of many uncertain factors. To predict and assess the annual expected sag frequency (ESF) deriving from the faults along lines, a stochastic based method that employs maximum entropy principle, namely the maximum entropy probability method (MEPM), has been introduced in this paper. Moreover, various types of faults have been considered systematically. With the fault line intervals and the sample moments taken into account, the discrete values of distribution probability of fault locations along the transmission lines have been estimat...
BackgroundMalaria is one of the most important tropical diseases that affects people globally. The influence of environmental conditions in the patterns of temporal distribution...Full Text Available
BackgroundIt is well established that Legionella pneumophila is a waterborne pathogen; by contrast, the mode of Helicobacter pylori transmission...Full Text Available
The paper presents an alternative approach for the studies of high voltage transmission lines based on artificial intelligence and more specifically artificial neural networks (ANNs). In contrast to the existing conventional-analytical techniques and simulations which are using in the calculations empirical and/or approximating equations, this approach is based only on actual field data and actual measurements. The proposed approach is applied on high voltage transmission lines in order to calculate the lightning outages, on grounding systems in order to assess the grounding resistance and on high voltage transmission lines' polluted insulators in order to estimate the critical flashover voltage. The obtained results are very close to the actual ones for all three case studies, something which clearly implies that the ANN approach is well working and has an acceptable accuracy, constituting an additional tool of ...
miles of high-voltage transmission lines with 12 intercon- nections to electricity systems in New York and Canada. As of 1 March 2003, ISO New England has ...
Summary 1.-The presence of Brucella abortus within free-ranging wildlife populations is an important conservation and management issue because of the risk of brucellosis transmission between wildlife and livestock. Predicting wildlife distributions is necessary to forecast wildlife and livestock spatial overlap and the potential for brucellosis transmission. 2.-We used Global Positioning System data collected from telemetry-collared female elk Cervus elaphus to develop resource selection function (RSF) models during the brucellosis transmission risk period (the abortion and calving periods). We validated extrapolation of predictive models at two nearby elk ranges within the Greater Yellowstone Ecosystem. Additionally, we integrated extrapolated RSF maps and domestic livestock distributions...
The symposium reviewed the use of electronics in mining today. Subjects covered include control systems; remote sensing; telemetry; data transmission; microprocessors and transportation systems. 15 papers have been abstracted separately.
Recently, independent system operators (ISOs) and others have published reports on the costs of transmission congestion. The magnitude of congestion costs cited in these reports has contributed to the national discussion on the current state of U.S. electricity transmission system and whether it provides an adequate platform for competition in wholesale electricity markets. This report reviews reports of congestion costs and begins to assess their implications for the current national discussion on the importance of the U.S. electricity transmission system for enabling competitive wholesale electricity markets. As a guiding principle, we posit that a more robust electricity system could reduce congestion costs; and thereby, (1) facilitate more vibrant and fair competition in wholesale electricity markets, and (2) enable consumers to seek out the lowest prices for electricity. Yet, examining the details suggests that, ...
Contact precautions are implemented to reduce transmission of multidrug-resistant organisms but may also increase hospital costs and patient complications. The goal of this study was to determine...Full Text Available
BackgroundThere is no data documenting the existence of a risk of infection transmission in ambulatory healthcare settings but concern remains. Our objective was to determine the...Full Text Available
Western Area Power Administration (Western) is a power marketing agency of the US Department of Energy, with jurisdiction in 15 western states. The Salt Lake City Area (SLCA) of Western performs the agency`s mission in parts of Colorado, New Mexico, Texas, Utah, Arizona, Wyoming, and Nevada. As part of its mission, Western owns, operates, and maintains a system of transmission lines for transmitting bulk electrical energy from points of generation to and between delivery points. Part of that system in southwestern Colorado includes the Blue Mesa-Curecanti and Blue Mesa-Salida 115-kV transmission lines. Western proposes to conduct maintenance and improve its access roads for these two transmission lines. This paper discusses the impacts to the existing environment as well as the environmental consequences resulting from the maintenance and construction that is proposed.
... is a standard in the utility industry which is used to study switching transients on power distribution networks and high-voltage transmission lines. ...
The pleiotropic actions of neuromodulators on pre- and postsynaptic targets present challenges to disentangling the mechanisms underlying regulation of synaptic transmission. Within the striatum,...Full Text Available
...smart grid applications where you could place them very close to the high-voltage transmission lines , very close to transformers and so on. Photo:...
Aerosol particles are ubiquitous in the troposphere and exert an important influence on global climate and the environment. They affect climate through scattering, transmission, and absorption of...Full Text Available
In the present scenario of market driven business, power supply has become more like a commodity. Reliable and quality power need to be ensured to meet customer requirements. In such a situation, it is extremely important that transmission line faults be identified accurately, reliably and in quick time. Advanced signal processing tools such as discrete wavelet transform (DWT) can be used very effectively for parameterisation and characterization of the fault signals. On the other hand, properly configured neural network (NN) can be utilized for classification of the faults based on the DWT signal. The present contribution uses electromagnetic transient program (EMTP) for modeling of a real transmission system and MATLAB for DWT and NN. Various types of faults have been simulated at different locations along the transmission line and an attempt has been made to correctly identify and locate the fault. (author)
Restructuring of power system has changed the traditional planning objectives and introduced challenges in the field of Transmission Expansion Planning (TEP). Due to these changes, new approaches and criteria are needed for transmission planning in deregulated environment. Therefore, in this paper, a dynamic expansion methodology is presented using a multi-objective optimization framework. Investment cost, congestion cost and reliability are considered in the optimization as three objectives. To overcome the difficulties in solving the non-convex and mixed integer nature of the optimization problems, a Non-Dominated Sorting Genetic Algorithm (NSGA II) approach is used followed by a fuzzy decision making analysis to obtain the final optimal solution. The planning methodology has been demonstrated on the IEEE 24-bus test system and north-east of Iran national 400 kV transmission grid to show the feasibility and capabilities ...
A community health survey of 438 individuals was taken to detect health problems related to high voltage electrical transmission among an adjacent residential population. Results revealed no significant or consistent relationships between exposure to a high voltage DC power line and the perceived health problems that were measured. The sample was not, however, large enough to draw statistically significant conclusions regarding possible health effects with a very low incidence.
This paper is a tutorial discussion of the basic principles of ground relaying for high voltage and extra high voltage transmission lines. Three different HV configurations are considered: Long lines, lines with a weak mid-point station, and mutually-coupled lines. Application criteria for EHV circuits are also discussed, and specific setting calculations are included where appropriate.
SummaryBackgroundInnovative prevention strategies for HIV-1 transmission are urgently needed. PRO2000 vaginal gel was efficacious against HIV-1 transmission in studies...Full Text Available
Overloaded transmission lines are only part of the problem. The ability of the network to carry power is also limited by the supply of reactive power and by frequency stability. Reactive power problems must be corrected in minutes, frequency stability problems in seconds. There is no way that market forces can handle these problems. Reactive power must be supplied to all long transmission and distribution lines to compensate for the loss of reactive volt-amperes - and resulting voltage drop - in the reactance along the line`s length. 7 figs.
The authors present a new concept: 'adaptive optimal reclosure' under transmission line faults by integrating the adaptive and optimal reclosure techniques. Simulation studies prove that the proposed technique is able to first detect the persistence time of fault path arc and then capture the optimal reclosure time, thereby enhancing system stability. (author)
Negative ion intensities of over 3 x 10/sup 5/ A/m/sup 2/ at energies of 2 MeV have been measured in a magnetically insulated transmission line. This negative ion production can affect the power flow in multiterawatt pulsed power devices, and may also have applications in the generation of high-intensity neutral or negative ion beams.
The demands made on data transmission systems by modern mining companies are used to show why the currently used multiplexers cannot satisfy future requirement. The telecommunications department of Bergbau-Forschung GmbH is now developing a telecommunication system for underground work. The requirements made on this system are reported.
This paper investigates the calculation of availability for parallel transmission lines (two or more) in the same tower or on the same right of way. As in many studies, the development of mathematical models is an important step. The models are justified using historical data and known characteristics of power system elements. A statistical method was used to generalize the failure rate and repair rate from real operating data. Application of the new model (which combines common-mode, simultaneous independent, and dependent outages) is discussed.
A 68 MeV neutron transmission experiment on iron has been analyzed with MCNPX using the Los Alamos LA150 neutron data library, the ECN/BRC 150 MeV neutron data library and with the intranuclear cascade code LAHET. The clear improvement of using the data libraries is confirmed. Also, other materials present in LA150 have been checked using the same MCNPX set-up. 10 refs.
The use of irrigation systems in the proximity of high voltage transmission lines is increasing. This study examines the induced voltages and currents on a pivotal irrigation system operating under a 765 kV line. With a few simple precautions such as a system can be operated in complete safety. 1 ref.
Populations living close to high-voltage transmission lines often have residential magnetic field exposures in excess of 1 microT, and sometimes over 2 microT. Yet, populations studied in most epidemiologic...Full Text Available
A broad-based, multidisciplinary research program is being conducted to study biological effects of electric and magnetic fields from high-voltage transmission lines. Assistance and technical support for this program are reported. (DLC)
This patent describes a {gamma}-ray detector. It comprises: a dislocation-free single crystal having an input surface and a transmission surface at opposite ends thereof; an active shield surrounding the crystal and functioning as an anticoincidence counter; and {gamma}-ray detector means disposed adjacent the transmission surface of the crystal for receiving and detecting {gamma}-rays of a predetermined wavelength incident on the input surface of the crystal at a specific Bragg angle and transmitted through the crystal.
The study examined the possibility for fuel ignition by spark discharge caused by induction effects under high voltage transmission lines. Theoretical background information on capacitive spark discharges and fuel ignition processes is given. Laboratory experiments were conducted to test the dependence of fuel ignition on three parameters: impedance in discharge path, multiple discharges, and larger electrode shapes. The results of these tests are discussed in terms of fuel ignition possibilities under high voltage transmission lines.
SiO{sub 2}, TiO{sub 2} and AlO(OH) powders obtained by the sol-gel method were investigated by transmission electron microscopy. The mass-radius relation was used to determine the fractal dimensions from the images. These fractal dimensions were corrected in order to obtain the powder fractal dimensions. The results indicate a good fractal behavior and high fractal dimensions.
The Department of Energy (DOE), Western Area Power Administration (Western) proposes to consolidate segments of two transmission lines near the Gering Substation in Gering, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska, within the city of Gering. Presently, there are three parallel 115-kilovolt (kV) transmission lines on separate rights-of-way (ROW) that terminate at the Gering Substation. The project would include dismantling the Archer-Gering wood-pole transmission line and rebuilding the remaining two lines on single-pole steel double circuit structures. The project would consolidate the Gering-Stegall North and Gering-Stegall South 115-kV transmission lines on to one ROW for a 1.33-mile segment between the Gering Substation and a point west of the ...
The Department of Energy (DOE), Western Area Power Administration (Western) proposes to consolidate segments of two transmission lines near the Gering Substation in Gering, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska, within the city of Gering. Presently, there are three parallel 115-kilovolt (kV) transmission lines on separate rights-of-way (ROW) that terminate at the Gering Substation. The project would include dismantling the Archer-Gering wood-pole transmission line and rebuilding the remaining two lines on single-pole steel double circuit structures. The project would consolidate the Gering-Stegall North and Gering-Stegall South 115-kV transmission lines on to one ROW for a 1.33-mile segment between the Gering Substation and a point west of the ...
Statistical detail is given of the electricity generation and transmission systems in the UK. Breakdown by type of station, by fuel and the proportion generated by others apart from the generating or area boards is presented. Figures are provided for the various high voltage transmission lines in terms of route and circuit length as well as the number of towers and the capacity of mains transformers.
This paper shows a computerized system, that adopt a statistical methodology and simultaneous measurements of wind velocity and environment temperature, as an experiences at the power transmission lines with environmental monitoring systems. 9 figs., 16 refs.
A heuristic algorithm that employs fuzzy logic is proposed to the power system transmission expansion planning problem. The algorithm is based on the divide to conquer strategy, which is controlled by the fuzzy system. The algorithm provides high quality solutions with the use of fuzzy decision making, which is based on nondeterministic criteria to guide the search. The fuzzy system provides a self-adjusting mechanism that eliminates the manual adjustment of parameters to each system being solved. (author)
The influence that electromagnetic fields have on mechanical and electronic equipment was discussed. A three dimensional numerical simulation model of electric fields around high voltage power transmission lines was described. 4 refs., 1 tab., 5 figs.
The influence that electromagnetic fields have on mechanical and electronic equipment was discussed. A three dimensional numerical simulation model of electric fields around high voltage power transmission lines was described. 4 refs., 1 tab., 5 figs.
When constructing new high-voltage transmission lines landscape aspects play a more and more important role. The project described is particularly interesting as it demonstrates that it is possible to find acceptable solutions for everyone if all partners are prepared to make concessions. The article also describes a new concept for the connection of concrete tower elements. (orig.).
Recent development in application of a focused ion beam (FIB) technique to preparation of thin foil specimens for transmission electron microscopy (TEM) observation has been reviewed. Combined technique of FIB/TEM enables one to analyze those microstructures which have been almost impossible or very difficult to analyze so far. (author)
Gonadotropin–releasing hormone (GnRH) neurons are the central regulators of reproduction. GABAergic transmission plays a critical role in pubertal activation of pulsatile GnRH secretion....Full Text Available
A new technique is described in this paper for a general active radio frequency (RF) filter trap that can be used for suppressing noise or interference on high voltage (HV) transmission lines. The technique exploits the Miller effect of an RF amplifier in conjunction with a special sensing circuit, and is potentially far more economical to implement than conventional techniques that use passive HV filter components.
An approach for classification of transmission line faults is presented. The approach is based on fuzzy logic and requires the consideration of the samples of three phase currents at one end of transmission line. To illustrate the effectiveness of the proposed approach extensive simulation studies, using EMTP and MATLAB, have been carried out for different types of fault considering wide variations in the operating conditions. (author)
During the last several years, audible noise produced by high voltage transmission lines in corona has emerged as an important design consideration. In this same time frame a number of different methods for calculating audible noise levels have been proposed. The methods currently available, for both ac and dc lines, are described in this paper and are compared through application to practical line geometries for which data from long-term measurements are available.
The existence, in real-time, of transmission constraints, demand forecasting errors, generator failures, and other factors impose additional costs through the need to run more expensive generation. These costs can appear as a significant component of the wholesale price to demand served by electricity markets operated over transmission networks. In the England & Wales Pool these costs are passed through directly to supply companies. The Transmission System Operator ({open_quotes}TSO{close_quotes}) can exert significant influence on these costs through improved availability of transmission circuits and through appropriate investment, but has no incentive to do so. Since the inception of the Pool, these costs have increased in level and volatility, and have proved difficult to hedge. In response, St Clements Services were instrumental in assisting Pool members to develop an {open_quotes}Uplift ...
A methodology for assessing the lightning performance of Hellenic high voltage transmission lines has been developed. Its main advantage is that the analysed transmission line is divided into regions and the analysis is conducted separately for each one region, taking into account the individual characteristics, which exist in each one of them. The developed approach intends to offer more accuracy in the assessment of lightning performance of Hellenic high voltage transmission lines and of similar lines, where they run at the same time through a plain region, a coastline and/or a mountainous region. The aims of the paper are to describe in detail the proposed methodology and to present results obtained by its application on operating Hellenic transmission lines of 150 and 400 kV. The computed results are compared with the results produced by another software tool published in the technical literature ...
This study examines the sensitivity of the travel time distribution predicted by a reference case model to (1) scale of representation of the model parameters, (2) size of the model domain, (3) correlation range of log-transmissivity, and (4) cross correlations between transmissivity and effective thickness. The basis for the reference model is the preliminary stochastic travel time model previously documented by the Basalt Waste Isolation Project. Results of this study show the following. The variability of the predicted travel times can be adequately represented when the ratio between the size of the zones used to represent the model parameters and the log-transmissivity correlation range is less than about one-fifth. The size of the model domain and the types of boundary conditions can have a strong impact on the distribution of travel times. Longer log-transmissivity correlation ranges cause larger ...
This paper presents a method for the optimal design of high voltage transmission lines taking into consideration shielding and backflashover failure rates. The minimization of suitably defined performance indices, which relate the failures caused by lightning in a transmission line to both line insulation level and tower footing resistance, is aimed. Optimum values for both line insulation level and tower footing resistance are calculated. The method is applied on several operating Hellenic transmission lines of 150 and 400kV, respectively, carefully selected among others, due to their high failure rates during lightning thunderstorms. Special attention has been paid on open loop lines, where a possible failure could bring the system out of service causing significant problems. The obtained design parameters, which reduce the failure rates caused by lightning, are compared with the existing design parameters of the ...
Accuracy of an LLP system and a lightning frequency map is evaluated by using transmission line faults in Hokuriku area from November in 1993 to October in 1996. The accuracy and efficiency of the system were calculated by statistical methods. From the above results, the lightning frequency map with 10 minutes meshes was proved capable of replacing the Isokeraunic Level Map with 15 minutes meshes used now for lightning protection design. However, the correlation between the number of detected lightning flashes and transmission line faults in each mesh was found to be week. This result suggests that more detailed analysis taking account of the length of transmission lines in each mesh is necessary. The correlation is stronger in winter than in summer, despite the fact that there is difference in the lightning current distribution in each mesh in winter. This characteristic can be explained if upward flashes from ...
Recently the troubles related to the network security have often occurred at KEK. According to their security policy, the authors have started the strategy against the daily attacks. It consists of two fundamental things; the monitoring and the access control. To monitor the network, the authors have installed the intrusion detection system and have managed it since 1998. For the second thing, the authors arranged three categories to classify all hosts (about 5000 hosts) at KEK according to their security level. To realize these three categories, the authors filter the incoming packet from outside KEK whether it has a SYN flag or not. The network monitoring and the access control produced good effects in keeping the security level high. Since 2000 the authors have started the transition of LAN from shared-media network to switched network. Now almost part of LAN was re-configured and in this new LAN 10 Mbps 100 Mbps/1Gbps Ethernet are supported. Currently the ...
The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform the data analysis. WAND system minimum detectable activities (MDAs) for point sources ...
The environment - external or internal degrees of freedom coupled to the object of interest - can, in effect, monitor some of its observables. As a result, the eigenstates of these observables decohere and behave like classical states. Continuous destruction of superpositions leads to the effective environment-induced superselection (einselection), which is beginning to be recognized as a key step in the transition from quantum to classical. We investigate it here in the context of quantum chaos. I show that the evolution of a chaotic macroscopic system is not just difficult to predict (requiring accuracy exponentially increasing with time) but quickly ceases to be deterministic in principle as a result of the Heisenberg uncertainty (which limits the available resolution). This happens after a time t{sub {Dirac_h}} which is only logarithmic in the Planck constant. For example, various components of the solar system are chaotic, with the Lyapunov timescales ranging from a bit more then ...
In this work dosimetric analysis using thermoluminescence technique to study the beams characteristics of x-rays employed in dental radiology has been carried out. The obtained results with CaSO{sub 4}:Dy thermoluminescent dosimeters (TLD) were compared to the doses obtained with parallel-plates ionization chamber. Dosimetric evaluations were also done using radiographic films of large dimensions. The x-rays equipments analyzed were installed in the radiological services of Odontology Department of Sergipe Federal University (U.F.S.). Depending on the anatomical region to be examined the proper exposure time was select, for a fix voltage of 70 kV. The results with TLD and ionization chamber have been determined to female and male individuals. The intraoral regions analysed were the peri apical of the incisors, molar and pre-molar teeth and the occlusive region. These regions were simulated using acrylic plates absorbers installed on the film packet holder. The ...
Pumped storage plants participate in two structurally different markets: the market for scheduled energy (also known as spot market) and the reserve market. In order to achieve the best possible plant scheduling in terms of revenues the marketing of the available capacity from pumped storage plants needs to be optimised in both markets. Moreover, due to the abilities for providing reserve, pumped storage capacities within an existing power plant portfolio can lead to synergies for the whole portfolio. The optimised combined participation of a power plant in both spot and reserve market as well as the coherent portfolio effect are considered as particular challenges in energy economic assessments, e.g. in the light of investment decisions. Based on an extension project and in cooperation with RWTH Aachen University an optimised combined participation of a power plant in both markets was simulated for the first time, thereby applying an ...
Nanocrystalline cemented tungsten carbide has attracted considerable interests for use in cutting tool because of its superior mechanical properties. In this study, nano-sized powders of mixed WC and Co were prepared from attrition-milled oxides by a gas reduction-carburization process. The effects of compacting pressure, heating schedule, additional ball-milling, and the presence of a grain growth inhibitor on the sintering properties of the nano-sized WC-Co powders were examined. The grain size and phases in WC-Co alloy were clearly affected by compacting pressure. Because of the trapped gases and the lower melting point of the cobalt binder, when a compact of nano-sized WC-Co powder was sintered through a heating schedule with holding steps, the sintered alloy maintained the small size of WC grains without any {eta} phase. In addition, the additional ball-milling improved the microstructure and mechanical properties of the nano-sized WC-Co ...
Nanocrystalline cemented tungsten carbide has attracted considerable interests for use in cutting tool because of its superior mechanical properties. In this study, nano-sized powders of mixed WC and Co were prepared from attrition-milled oxides by a gas reduction-carburization process. The effects of compacting pressure, heating schedule, additional ball-milling, and the presence of a grain growth inhibitor on the sintering properties of the nano-sized WC-Co powders were examined. The grain size and phases in WC-Co alloy were clearly affected by compacting pressure. Because of the trapped gases and the lower melting point of the cobalt binder, when a compact of nano-sized WC-Co powder was sintered through a heating schedule with holding steps, the sintered alloy maintained the small size of WC grains without any #eta# phase. In addition, the additional ball-milling improved the microstructure and mechanical properties of the nano-sized WC-Co ...
Rats were exposed to lead (Pb) before or after weaning. For preweaning exposures, nursing dams received 0.2% Pb acetate(1090 ppm Pb) in drinking water. Offspring treated after weaning consumed the same concentration. Tapwater served as the control fluid. Pre-post treatments were distributed among four experimental groups of 10 rats each: tap water-tap water, Pb-tap water, tap water-Pb, Pb-Pb. Operant behavior training began on Postnatal Day 58. Animals performed on a multiple reinforcement schedule of food presentation consisting of fixed-interval, fixed-ratio, and time out components.Statistical analyses of experimental sessions 4 to 11 (Postnatal Days 72 to 79) revealed that postweaning exposure significantly lengthened the median interval (interresponse time) between consecutive responses on both the interval and ratio schedules. Preweaning exposure alone tended to produce a shortening of the median interresponse time. Other performance ...
This document outlines the Maintenance Implementation Plan (MIP) for the Plutonium Finishing Plant (PFP) located at the Hanford site at Richland, Washington. This MIP describes the PFP maintenance program relative to DOE order 4330.4B. The MIP defines the key actions needed to meet the guidelines of the Order to produce a cost-effective and efficient maintenance program. A previous report identified the presence of significant quantities of Pu-bearing materials within PFP that pose risks to workers. PFP`s current mission is to develop, install and operate processes which will mitigate these risks. The PFP Maintenance strategy is to equip the facility with systems and equipment able to sustain scheduled PFP operations. The current operating run is scheduled to last seven years. Activities following the stabilization operation will involve an Environmental Impact Statement (EIS) to determine future plant activities. This strategy includes ...
The authors will be conducting an integrated seismic experiment to image the structure of the crust and upper mantle of northern California immediately before and after passage of the Mendocino Triple Junction. The purpose of this representation is to describe the project to other scientists interested in geological and geophysical processes in this region and to solicit input relevant to detailed siting of the funded seismic profiles. The experiment encompasses two field seasons: onshore seismic refraction/wide angle reflection data acquisition along three long profiles scheduled for late summer, 1993; and MCS deep crustal seismic reflection data acquisition accompanied by simultaneous large aperture recording using both ocean bottom and onshore seismographs, tentatively scheduled for summer, 1994. This study represents a component of a long-term, multi-disciplinary effort on the part of many investigators to exploit this well defined system ...
In the paper, a fuzzy decision-making methodology is presented to decide the generation schedule of long-term hydrothermal problems with explicit recognition of statistical uncertainties in system production cost data, NO{sub x} emission data, system load demand and hydro reservoir water inflows. In deciding the optimal operation, three objectives operating cost, NO{sub x} emission and unsatisfied load demand over the whole of the planning period are simultaneously minimised. Specific technique is put forth to convert the stochastic models into their deterministic equivalents. The weighted minimax method is used to simulate the tradeoff relation between the conflicting objectives in the non-inferior domain. The fuzzy set theory is exploited to choose the best operating point over the tradeoff curve. An efficient decomposition technique is applied to reduce the complexity of the problem. In each subproblem, thermal generations are obtained by using simplified method ...
Although the Federal Facility Agreement (FFA) addresses the entire Oak Ridge Reservation, specific requirements are set forth for the liquid low-level radioactive waste (LLLW) storage tanks and their associated piping and equipment, tank systems, at ORNL. The stated objected of the FFA as it relates to these tank systems is to ensure that structural integrity, containment and detection of releases, and source control are maintained pending final remedial action at the site. The FFA requires that leaking LLLW tank systems be immediately removed from service. It also requires the LLLW tank systems that do not meet the design and performance requirements established for secondary containment and leak detection be either upgraded or replaced. The FFA establishes a procedural framework for implementing the environmental laws. For the LLLW tank systems, this framework requires the specified plans and schedules be submitted to EPA and TDEC for approval within 60 days, or ...
The Tank Waste Remediation System (TWRS) Program mission is to store, treat, and immobilize highly radioactive Hanford Site waste (current and future tank waste and the strontium/cesium capsules) in an environmentally sound, safe, and cost-effective manner. The scope of the TWRS Waste Pretreatment Program is to treat tank waste and separate that waste into HLW and LLW fractions and provide additional treatment as required to feed LLW and HLW immobilization facilities. Enhanced sludge washing was chosen as the baseline process for separating Hanford tank waste sludge. Section 1.0 briefly discusses the purpose of the evaluation plan and provides the background that led to the choice of enhanced sludge washing as the baseline process. Section 2.0 provides a brief summary of the evaluation plan details. Section 3.0 discusses, in some detail, the technical work planned to support the evaluation of enhanced sludge washing. Section 4.0 briefly discusses the potential important of policy ...
A glovebox was designed, fabricated, and mocked-up for the WIPP Gas Generation Experiments (GGE) being conducted at ANL-W. GGE will determine the gas generation rates from materials in contact handled transuranic waste at likely long term repository temperature and pressure conditions. Since the customer`s schedule did not permit time for performing R&D of the support systems, designing the glovebox, and fabricating the glovebox in a serial fashion, a parallel approach was undertaken. As R&D of the sampling system and other support systems was initiated, a specification was written concurrently for contracting a manufacturer to design and build the glovebox and support equipment. The contractor understood that the R&D being performed at ANL-W would add additional functional requirements to the glovebox design. Initially, the contractor had sufficient information to design the glovebox shell. Once the shell design was approved, ANL-W built a full scale ...
Heavy-duty trucks and buses are substantial contributors to the atmospheric oxides of nitrogen (NO_x) inventory, but prediction of their emissions in real use remains inchoate. Continuous emissions of NO_x were recorded from Chassis dynamometer testing of eight vehicles using a variety of transient cycles, including the Central Business District schedule. NO_x data were treated to account for sampling time lag and presented against instantaneous vehicle axle power. Data were repeatable from run to run and test schedule, but vehicle type and test cycle both influenced the instantaneous emissions rates. However, the resulting correlations may be used for mobile source NO_x contribution estimation when combined with vehicle activity data. The emissions data were also presented as NO_x/CO_2, which are valuable for comparison with remote sensing emissions data. The overall average ratio for all of the data considered was 0.0141, which corresponds to ...
An overview of the Canadian mining industry`s state of preparedness for the Year 2000 is presented. Committees within the mining industry are working on scheduling and implementing activities, defining criticality, monitoring remedial action, and contingency planning. The Mining Association of Canada is working with the Federal Government`s National Contingency Planning Group to deal with potential threats to health and security. Survey results suggest that mining poses a low to medium risk based on the state of planning for Y2K. The results of a survey of member preparedness is tabulated. 1 tab.
An overall view of the 1982 plant operating performance is presented. All periods of ON-FEED operation, UNSCHEDULED SHUTDOWNS, and SCHEDULED SHUTDOWNS are accounted for and tabulated. Causes of UNSCHEDULED SHUTDOWNS are identified and discussed. Plant solutions aimed at reducing the effect of similar future shutdowns or preventing recurrence of such shutdowns are explained. Details of repeated, major maintenance problems with various pieces of equipment are presented. Discussion of each problem and solutions found during 1982 are given, where applicable.
A summary of the 1983 Critical Solvent Deashing unit performance at the Wilsonville Advanced Coal Liquefaction R and D Facility is presented. All periods of on feed operation, unscheduled shutdowns, and scheduled shutdowns are accounted for and tabulated. Causes of unscheduled shutdowns are identified and discussed. Details of repeated, major maintenance problems with various pieces of equipment are presented. Where applicable, solutions are discussed. Historical operations and maintenance data are presented and used for comparison purposes in order to better indicate areas of improvement in the unit. 4 references, 7 figures, 3 tables.
The United States Department of Energy (DOE) is committed to providing high quality products that satisfy customer needs and are the associated with this goal, DOE personnel must possess the knowledge, skills, and abilities to ensure successful job performance. In addition, there must be recognition that the greatest obstacle to proper project performance is inadequate project definition. Without strong project definition, DOE environmental management efforts are vulnerable to fragmented solutions, duplication of effort, and wastes resources. The primary means of ensuring environmental management projects meet cost and schedule milestones is through a structured and graded approach to project definition, which is the focus of this handbook.
A schematic of the Bench cavity receiver system is given, and the primary objectives, schedule and research plan for each of four tests are discussed. The tests are: (1) cold flow testing to functionally check all valves and their response using high pressure nitrogen gas; (2) a hot checkout to simulate both steady state and transient flux inputs to the receiver which are expected at the French facility; (3) basic performance using solar energy at the French facility; and (4) ir radiant heat testing. (LEW)
The primary purpose of the Waste Management Program Plan is to provide an annual report of how Waste Management's operations are conducted, what facilities are being used to manage wastes, what forces are acting to change current waste management systems, and what plans are in store for the coming fiscal year. In addition, this document projects activities for several years beyond the coming fiscal year in order to adequately plan for safe handling, storage, and disposal of radioactive wastes generated at the Savannah River Site and for developing technology for improved management of wastes. In this document, work descriptions and milestone schedules are current as of December 1991.
Guidelines and ground rules followed in the development of requirements for the SPS are presented. Development planning objectives are specified in each of these areas, and evolutionary SPS program scenarios are described for the various concepts studied during the past one year contract. Program descriptions are presented as planning packages of technical tasks, and schedule phasing. Each package identifies the ground based technology effort that will facilitate SPS definitions, designs, development, and operations.
The DOE`s clean-up of its nuclear complex require the development of innovative technologies to convert soils contaminated by hazardous and/or radioactive wastes to forms which can be readily disposed in accordance with current waste disposal methods. The unique features of Votec CMS technology should make it particularly cost-effective process for the vitrification of soils, sediments, sludges, and mill tailings containing organic metallic and/or radioactive contaminants. This article describes the technology (Votec`s combustion and melting system), the results of testing, the demonstration plant system, and summarizes the future schedule and the equipment needed. 3 figs., 3 tabs.
This paper describes a simulation model for predicting end-use energy consumption in residential sectors of a city or region. In this model, the annual energy consumption of a dwelling is simulated from the occupants' schedule of living activities, weather data and energy efficiencies of appliances and dwellings. By summing up the simulation results for various household categories, total energy consumption for the residential sector in a region can be estimated. In this paper, energy consumption for Osaka City is simulated. The result is compared with statistical data. The effects of energy efficiency standards and urban heat island phenomena are examined. (author)
Fifty patients scheduled to undergo IVF received a standard anesthetic of fentanyl and propofol for induction, followed by propofol infusion, with Bispectral index values and modified Ramsey sedation scores recorded at 5-minute intervals for the duration of anesthesia care. Moderate sedation was found only transiently during the first 5-10 minutes of the oocyte retrieval, but thereafter the level of sedation increased, with deep sedation and general anesthesia measured in all patients as determined by both the Bispectral index scores and lack of response to painful stimulation.
Construction and commissioning period of NPP are reduced world over drastically by stringent schedule for financial and economic reasons. For meeting the schedule, commissioning of components and systems are started immediate after installation, while construction activities are continued in parallel at the same place. Parallel activities' and 'Time Constraint' have brought new challenges to 'Management of Fire and Industrial Safely' during commissioning. An innovative approach was used during such phase of commissioning of TAPP-3 and 4. This paper outlines challenges encountered during this phase and special approach and measures used to meet those challenges. This paper also outlines problems encountered during implementation of these measures and subsequent change in approach to ensure smooth and safe execution of activities. Primarily, challenges were conflicting requirements by various agencies to carryout commissioning in parallel with ...
Novel lightweight bricks have been produced by sintering mixes of dried water treatment sludge and rice husk. Samples containing up to 20 wt.% rice husk have been fired using a heating schedule that allowed effective organic burn-out. Rice husk addition increased the porosity of sintered samples and higher sintering temperatures increased compressive strengths. Materials containing 15 wt.% rice husk that were sintered at 1100 degrees C produced low bulk density and relatively high strength materials that were compliant with relevant Taiwan standards for use as lightweight bricks. PMID:19596512
This is the ninth quarterly report as required by the Hanford Federal Facility Agreement and Consent Order (Ecology et al. 1990), also known as the Tri-Party Agreement, established between the US Department of Energy (DOE), the US Environmental Protection Agency (EPA), and the Washington State Department of Ecology (Ecology). The Tri-Party Agreement sets the plan and schedule for achieving regulatory compliance and cleanup of waste sites at the Hanford Site. This report covers progress for the quarter that ended June 30, 1991. A total of 87 milestones have been completed to date. 39 refs., 1 fig.
Daya Bay Neutrino Experiment is dedicated to measuring the last unobserved neutrino mixing angle theta_13. The predicted precision on sin^2(2theta_13) is 0.01 at 90% confidence level. This document briefly reviews the measurement method and detector construction status. The first two anti-neutrino detectors' dry run result is also discussed. The Daya Bay near hall data taking is expected to commence in the summer of 2011 and the data taking of all of the three halls in the summer of 2012.
In the construction work for the Unit No.5 Turbine Building at Hamaoka Nuclear Power Station, the collaboration work for the planning and the coordination of the building construction and the machinery installation was carried out utilizing three-dimensional computer aided design (3D CAD) information. It was the first time in Japan for a building constructor and a plant manufacturer to work together, exchanging 3D CAD data of the whole building and adjusting the construction schedule. It was made possible to confirm the correspondence concerning the planning of both companies from the primary stage of the project by the total process simulation and to adjust on-going work precisely by the partial process simulation.
In the construction work for the Unit No.5 Turbine Building at Hamaoka Nuclear Power Station, the collaboration work for the planning and the coordination of the building construction and the machinery installation was carried out utilizing three-dimensional computer aided design (3D CAD) information. It was the first time in Japan for a building constructor and a plant manufacturer to work together, exchanging 3D CAD data of the whole building and adjusting the construction schedule. It was made possible to confirm the correspondence concerning the planning of both companies from the primary stage of the project by the total process simulation and to adjust on-going work precisely by the partial process simulation.
This handbook covers the general area of lubrication and tribology in all its facets: friction, wear lubricants (liquid, solid, and gas), greases, lubrication principles, applications to various mechanisms, design principles of devices incorporating lubrication, maintenance, lubrication scheduling, and standardized tests; as well as environmental problems and conservation. The information contained in these two volumes will aid in achieving effective lubrication for control of friction and wear, and is another step to improve understanding of the complex factors involved in tribology. Both metric and English units are provided throughout both volumes.
This proceedings volume contains contributions by about 70 authors on market trends, funding, marketing, boundary conditions and sales promotion of thermal solar energy and photovoltaic systems. The contributions reflect the diversity of authors, e.g. consultants, advocates and agents of solar technology producers and financial organisations. Central issues were markets in and outside Europe, quality assurance, interdepartmental cooperations, and marketing strategies of the solar industry. The proceedings volume also contains the conference schedule and self-descriptions of the authors' institutions. (orig.)
Light composite sandwich panels are increasingly used in automobiles, ships and aircraft, because of the advantages they offer of high strength-to-weight ratios. However, the acoustical properties of these light and stiff structures can be less desirable than those of equivalent metal panels. These undesirable properties can lead to high interior noise levels. A number of researchers have studied the acoustical properties of honeycomb and foam sandwich panels. Not much work, however, has been carried out on foam-filled honeycomb sandwich panels. In this dissertation, governing equations for the forced vibration of asymmetric sandwich panels are developed. An analytical expression for modal densities of symmetric sandwich panels is derived from a sixth-order governing equation. A boundary element analysis model for the sound transmission loss of symmetric sandwich panels is proposed. Measurements of the modal density, total loss factor, radiation loss factor, and ...
In this paper we present an overview of the literature on efficacy and safety trials of the various pneumococcal conjugate vaccines on the market (PCV7) and in development (PCV9, PCV11 and allegedly PCV10 and PCV13), as well as of observations from post-licensure studies. Seven- (PCV7) and nine-valent PCV (PCV9) are reported to be sufficiently immunogenic after administration of a 3+1 schedule in infants in various RCTs. PncOMPC (PCV7 with a protein of N. meningitidis as a carrier) is less immunogenic, though this may have no repercussions for the protective efficacy against clinical disease. PCV7 is 82-97% efficacious against vaccine serotype (VT) IPD, 90% efficacious against (clinically diagnosed) pneumococcal pneumonia, and, like the 11-valent PCV, 57% efficacious against VT acute otitis media. Naturally, it would be of paramount public health interest if the same levels of efficacy and effectiveness could be achieved with fewer doses. Trials studying 2+1 ...
These studies have addressed firstly the effect of single small doses of x-ray upon murine hematopoietic stem cells to obtain a better estimate of the D/sub q/. It is small, of the order of 20 rads. Secondly, a dose fractionation schedule tht does not kill or perturb the kinetics of hemopoietic cell proliferation was sought in order to investigate the leukemogenic potential of low level radiation upon an unperturbed hemopoietic system. The studies reported herein show tht 1.25 rads every other day decrease the CFU-S content of bone marrow by the time 40 rads are accumulated. Studies on the effect of 0.5, 1.0, 2.0, and 3.0 rads 3 times per week are under way. Two rads 3 times per week produced a modest decrease in CFU-S content of bone marrow after an accumulation of 68 rads. With 3.0 rads 3 times per week an accumulation of 102 rads produces a significant decrease in CFU-S content of bone marrow. Dose fractionation at 0.5 and 1.0 rad 3 times per week has not ...
The most important commercialized methods of attenuation correction in SPECT are based on attenuation coefficient map from a transmission imaging method. The transmission imaging system can be the linear source of radioelement or a X-ray CT system. The image of transmission imaging system is not useful unless to replacement of the attenuation coefficient or CT number with the attenuation coefficient in SPECT energy. In this paper we essay to evaluate the validity and estimate the error of the most used method of this transformation. The final result shows that the methods which use a linear or multi-linear curve accept a error in their estimation. The value of mA is not important but the patient thickness is very important and it can introduce a error more than 10 percent in the final result.
Transmission nuclear resonance fluorescence measurements were made on targets consisting of Pb and depleted U with total areal densities near 86g/cm"2. The "2"3"8U content in the targets varied from 0% to 8.5% (atom fraction). The experiment demonstrates the capability of using transmission measurements as a non-destructive technique to identify and quantify the presence of an isotope in samples with thicknesses comparable to the average thickness of a nuclear fuel assembly. The experimental data also appear to demonstrate the process of notch refilling with a predictable intensity. Comparison of measured spectra to previous backscatter "2"3"8U measurements indicates general agreement in observed excited states. Evidence of two new "2"3"8U excited states and possibly a third state have also been observed.
Due to deregulation, the electrical power industry is undergoing deep changes, moving towards an open market. Two kinds of parties are active in the new environment: the economical agents (producers, consumers, brokers) and the power system operator, the former interested in power exchanges and their economic value, the latter in bus injections and their threat to the security of the transmission network. The variables used to model the transmission network operation have to be meaningful to the power system operator as well as to the economical parties; the action rules followed by the power system operator to enforce network security have to be carefully designed to be equitable and non-discriminatory. In this paper, a modeling of the power exchanges is proposed in the form of multilateral trades, and some rules for the action of the power system operator are proposed and discussed. The results obtained on a simple study case are discussed. ...
We present the design of a diagnostic system to measure electron cyclotron absorption at the second harmonic E-mode resonance in the JET pumped divertor plasma. The diagnostic will measure transmission as a function of frequency along one or more sightlines from which the spatial profile of the n_eT_e product will be deduced. The divertor is briefly described, and the electron cyclotron resonance physics relevant to this measurement is reviewed. The problems of measuring transmission using an oversized transmission system are discussed and the chosen measurement technique, a swept frequency interferometer using a coherent radiation source, is described. A prototype of the instrument has been assembled to test the measurement technique. Some data demonstrating the instrument's characteristics are presented. The nonresonant losses, which may affect the interpretation of the measurement, are also discussed. (orig.).
Recognizing that a high percentage of transmission-line faults are single-phase to earth and temporary in nature, provides the impetus for considering single-pole switching as a means to enhance the reliability of EHV transmission systems. The effectiveness of single-pole switching schemes is largely determined by the speed with which the secondary arcs extinguish, and hence allow system restoration. Simulation techniques that enable better prediction of the faulted-system response are of obvious importance to the design and assessment of the various single-pole switching scheme applications. In this thesis, digital methods are developed to enable the faulted response of EHV systems to be simulated for a variety of different single-pole switching schemes. These include conventional single-pole switching, the hybrid method of autoreclosure, the neutral switched reactor, and the High Speed Grounding Switch implementations. The work is of ...
Exploding bridgewire detonators with fine PETN powder were fabricated by the almost same method as the assembling process of ordinary electric detonators and the relationship between the detonating condition (bridge current waveform) in the single detonator initiation and the transmission time was studied. In addition, its jitter was also examined by simultaneous initiation of the detonators connected in series. It was revealed that the transmission time varied almost linearly against the inverse number of the rate of current rise and this variation was mainly due to the time needed for the bridgewire explosion. The jitter of the transmission time was within 0.1 microsecond. Although the cause of the jitter could not be determined, it was considered feasible to reduce the time jitter further by minimizing dimentional tolerances of fixing plugs and improving the loading process of PETN powder. 11 refs., 6 figs.
Pd was deposited onto Si (111) 7x7 surface at approximately 700 K inside an ultrahigh vacuum transmission electron microscope. Plan-viewed transmission electron microscopy (TEM) observation indicated that the islands have two kinds of shapes, round and rectangular (one-dimensional) ones. In a diffraction pattern for the rectangular islands, extra spots along the <110> direction of the Si surface, spacing of which is 1/8 times as long as that of Si (220) spots, were seen. A high resolution TEM image showed the corresponding superstructure in the rectangular islands. In situ observation of the growing process of the rectangular islands showed repeat of introduction and relief of strains during the growth, suggesting that such superstructure would be constructed by stacking compositionally different phases or introducing defects so that the periodically maximized strain is relieved.
The transmission of electrical energy by use of underground cables is increasing. Fault location techniques have certain limitations; incipient fault detection and location would help reduce the maintenance cost of these lines as well as improve the reliability of service. The report discusses some test results related to RF-probing techniques applied to high-voltage transmission lines. The high-frequency losses and attenuation in high-voltage cables places certain ultimate limitations on RF-probing techniques for incipient fault detection. Time-domain reflectrometry methods were employed to assess the RF-transmission properties of high-voltage cables at frequencies as high as 6 GHz. Fast-Fourier-transform deconvolution was used to obtain loss measurements as a function of frequency. The loss mechanisms were identified. The measurement hardware and methods are discussed as well as analysis approach leading to the ...
Rapid and reliable transmission of nuclear medicine studies using conventional telephone lines and commercially available modems and computer systems has been accomplished through use of software developed within the authors' hospital. Original digital images of all-night and weekend studies, acquired on any of the acquisition computers from different manufacturers, are now routinely sent for remote reading at the physician's home. Data, software, and letters are routinely exchanged using modems and standard telephone lines with a sister institution in Haifa, Israel. The software has been designed to achieve no loss data compression and minimal turnaround time loss. Thus, an average lung perfusion image or gallbladder study requires about 1-3 minutes of transmission time. Full analysis and display software is available on the remote computer.
This paper presents some situations, in which measurements of electromagnetic fields generated by transmission lines and substations should be performed. The range of measurements may differ, but maximum values of electric and magnetic fields and flux density must be identified in all situations. The area with electric field exceeding 1 kV/m should be identified as well. The author also presents basic requirements to be met by the measurement technique. These requirements are specified according to the national standard. Special attention should be paid to the identification of the spatial distribution of electric field and flux density generated in the vicinity of high voltage transmission lines. To verify the measurement results, it is necessary to calculate the distribution of both aforesaid field components. For environmental protection purposes, it is also proposed that the report should include measurements of electromagnetic fields of 50 ...
Concerns are sometimes expressed about an alleged link between exposure to the extremely low frequency electromagnetic fields occurring in proximity to electricity networks or equipment. Transmission lines are specifically mentioned. The underlying physical mechanisms are described by which electric and magnetic fields exist, with particular reference to high voltage transmission lines. Epidemiological and laboratory studies are the two approaches used in research into the subject and the shortcomings inherent in many such studies and the inconsistencies in the results are mentioned. Some of the more recent epidemiological studies are referred to, also the possible interaction mechanisms between fields and the human body. The work of certain international and national bodies which were established to review the results of research into the alleged association between electromagnetic fields and ill-health are reported. (R.P.)
The types of investigations undertaken to test for possible biological effects of extremely low frequency electric fields have been numerous. However, neither animal and plant experimentation nor clinical studies nor experience with operating extremely high voltage transmission lines have to date provided convincing evidence of a harmful effect from exposure to electric fields associated with transmission lines in spite of numerous attempts to find such effects. Analysis of internal fields and currents supports these observations as the levels appear to be too low to affect mammalian cells. Thus, while one can never prove the negative (i.e. that there is no effect), the overwhelming body of evidence indicates that the electric fields associated with high-voltage lines have no deleterious biological effects. (author).
In the present scenario of market driven business, power supply has become more like a commodity. Reliable and quality power need to be ensured to meet customer requirements. In such a situation, it is extremely important that transmission line faults be identified accurately, reliably and in quick time. Advanced signal processing tools such as discrete wavelet transform (DWT) can be used very effectively for parameterisation and characterization of the fault signals. On the other hand, properly configured neural network (NN) can be utilized for classification of the faults based on the DWT signal. The present contribution uses electromagnetic transient program (EMTP) for modeling of a real transmission system and MATLAB for DWT and NN. Various types of faults have been simulated at differ...
A reduced grid model of a transmission system with a number of central power plants, consumption centers, local wind turbines and a large offshore wind farm is developed and implemented in the simulation tool PowerFactory (DIgSILENT). The reduced grid model is given by Energinet.dk, Transmission System Operator of Denmark (TSO) for Natural Gas and Electricity, to the Danish Universities and the Risoe National Laboratory. Its intended usage is education and studying of interaction between electricity-producing wind turbines and a realistic transmission system. Focus in these studies is on voltage stability issues and on the ride-through capability of different wind turbine concepts, equipped with advanced controllers, developed by the Risoe National Laboratory.
Zoonoses are infections that are spread from animals to humans. Most often, humans are “dead-end” hosts, meaning that there is no subsequent human-to-human transmission. If one considers...Full Text Available
Salmonella mbandaka was isolated from cattle on three dairy farms. The duration of infection was less than four weeks and none of the animals became clinically ill. The animals had all consumed a diet...Full Text Available
This study was undertaken to determine which rodent species serve as primary reservoirs for the Lyme disease spirochete Borrelia burgdorferi in commonly occurring woodland types...Full Text Available
The influence of low-frequency electromagnetic field irradiating by high-voltage transmission lines on signal transduction of cell in spleen cells of the rates have been studied by molecular-biology techniques. The spleen cells are extracted from skilled rates, which are exposed in the electromagnetic field of high-voltage transmission lines with 4000 V/m and 0.09-0.1 G about 400 days. The quantity or level of phosphorylation of signal transducer and activator of transcription (STAT3) in JAK-STAT signal transduction pathway of spleen cells, which are stimulated and unstimulated by IL-2, respectively, are detected by the immunoblotting and immunobiochemistry. The results show that the expression of phospho-STAT3 in spleen cell stimulated by IL-2 differ not from that in the unstimulated cell. The former is significantly large than the latter. This shows that signal transduction of cell is affected by this electromagnetic field. The spectra of ...
BackgroundNaturally acquired immune responses against sexual stages of P. falciparum can reduce the transmission of malaria from humans to mosquitoes. These antigens...Full Text Available
In the absence of a vaccine, there is an urgent need for the development of safe and effective topical microbicides to prevent the sexual transmission of human immunodeficiency virus type 1 (HIV-1)....Full Text Available
We have investigated the nanotexture and crystallographic orientation of aragonite in a coral skeleton using synchrotron-based scanning transmission X-ray microscopy (STXM) and transmission electron microscopy (TEM). Polarization-dependent STXM imaging at 40-nm spatial resolution was used to obtain an orientation map of the c-axis of aragonite on a focused ion beam milled ultrathin section of a Porites coral. This imaging showed that one of the basic units of coral skeletons, referred to as the center of calcification (COC), consists of a cluster of 100-nm aragonite globules crystallographically aligned over several micrometers with a fan-like distribution and with the properties of single crystals at the mesoscale. The remainder of the skeleton consists of aragonite single-crystal fibers in crystallographic continuity with the nanoglobules comprising the COC. Our observation provides information on the nm-scale processes that led to biomineral ...
Malaria parasites must undergo a round of sexual reproduction in the blood meal of a mosquito vector to be transmitted between hosts. Developing a transmission-blocking intervention to prevent parasites...Full Text Available
BackgroundBuruli ulcer, the third mycobacterial disease after tuberculosis and leprosy, is caused by the environmental mycobacterium M. ulcerans. Various modes of...Full Text Available
Ross River virus (RRV) is a fascinating, important arbovirus that is endemic and enzootic in Australia and Papua New Guinea and was epidemic in the South Pacific in 1979 and 1980. Infection with RRV...Full Text Available
... biological effects of electromagnetic fields (EMFs) produced by high-voltage transmission lines have come under intense scrutiny, mostly with respect ... biological effects of electromagnetic fields (EMFs...
This paper describes radiography as one of the most efficient and cost effective methods for inspecting electric cabls. Details of one project in particular, i.e., the inspection of high-pressure, oil-filled, pipe-type cables (HPOF) are given. 2 refs.
Previous studies on knowledge of HIV transmission and prevention have used surveys. This study used the question box method to create a safe environment for collecting information on knowledge...Full Text Available
The morphogenesis of pulmonary edema and bronchiolar injury induced by the toxic furan, 4-ipomeanol, was studied by combined light and transmission electron microscopy. Weanling male CD-1 mice received...Full Text Available
Abstracts of research projects are presented in the following areas: measurements and special facilities; cellular and subcellular studies; physiology; behavior; environmental effects; modeling, scaling and dosimetry; and high voltage direct current. (ACR)
ObjectiveTo determine the prevalence of pathogens that cause sexually transmitted infections (STIs) in semen from asymptomatic male infertility patients with and...Full Text Available
Diseases of man caused by the virus of herpes simplex fall into two broad categories. The primary disease occurs only once in any individual's life and is caused by transmission of virus from an already...Full Text Available
The economics of renewable energy technologies when deployed in a decentralised manner are more favourable than the simple cost of the fossil fuel generated electricity displaced. They have capital and maintenance cost savings associated with the electrical transmission in infrastructures which are avoided. Worked examples are presented. (UK)
Mouse models for the study of autistic-like behaviors are increasingly needed to test hypotheses about the causes of autism, and to evaluate potential treatments. Both the automated 3-chambered...Full Text Available
BackgroundIndividuals living in malaria endemic areas generally harbour multiple parasite strains. Multiplicity of infection (MOI) can be an indicator of immune status. However,...Full Text Available
Several studies have raised the possibility that exposure to electrical and/or magnetic fields may be injurious to health in particular by the promotion or initiation of cancer. To investigate whether...Full Text Available
Cytological observations were made on developing seeds of soybean (Glycine max (L.) Merr. “Amsoy 71”) using scanning and transmission electron microscopy and light microscopy....Full Text Available
BackgroundMalaria is a major public health problem in Cameroon. Unlike in the southern forested areas where the epidemiology of malaria has been better studied prior to the implementation...Full Text Available
and antibody responses of rhesus macaques exposed to the human gammaretrovirus XMRV. J Virol. 2011 May ;85(9):4547-57. Epub 2011 Feb 16 . PubMed Surgical staging of early...
High-voltage transmission lines can be just as safe as the electrical wiring in the homes--or just as dangerous. The crucial factor is ourselves: they must learn to behave safely around them. This booklet is a basic safety guide for those who live and work around power lines. It deals primarily with nuisance shocks due to induced voltages, and with potential electric shock hazards from contact with high-voltage lines. References on possible long-term biological effects of transmission lines are shown. In preparing this booklet, the Bonneville Power Administration has drawn on more than 50 years of experience with high-voltage transmission. BPA operates one of the world`s largest networks of long-distance, high-voltage lines. This system has more than 400 substations and about 15,000 miles of transmission lines, almost 4,400 miles of which are operated at 500,000 volts.
This booklet presents safe practices that you should follow if your activities take you near high-voltage transmission lines. It documents information that has generally been available to the public.
Limitations of traveling wave relaying schemes for protection of overhead extra-high voltage transmission lines are investigated. A method of analysis of traveling wave phenomena for three phase transmission lines is developed in which the interdependent phase voltages and currents are decoupled into their modal counterparts, which are approximately independent. A time domain digital simulation program is used to solve the modal transmission line equations to obtain the fault induced traveling waves detected at the relay location. The frequency dependence of the aerial modes is ignored but their losses are included. A lumped element analysis method, originally developed for transient analysis of lossy coaxial cables, is adapted here to obtain approximate solution for the fault induced traveling waves of the ground mode. Excellent agreement is found between the results obtained by this method and frequency domain methods. ...
Synaptic gain control and information storage in neural networks are mediated by alterations in synaptic transmission, such as in long-term potentiation (LTP). Here, we show using both in...Full Text Available
Understanding the dynamics of porcine reproductive and respiratory syndrome virus (PRRSV) vertical transmission is important to enhance the accuracy of monitoring protocols for endemically infected...Full Text Available
BackgroundThe study aimed at (i) characterizing the mode of transmission of blaCTX-M and blaTEM-1 among extended-spectrum-β-lactamase...Full Text Available
The use of Bacillus thuringiensis (Bt) endotoxins to control insect vectors of human diseases and agricultural pests is threatened by the possible evolution of resistance in major pest...Full Text Available
The induction of voltages on pipelines and railroad signal wires can be a problem when high-voltage transmission lines share the right of way. A handbook and two computer programs provide the analytic tools for utilities to avoid the problem.
Sustainable management of toilet waste must prevent disease transmission but allow reuse of plant nutrients. Inactivation of uterus-derived Ascaris suum eggs was studied in relation...Full Text Available
Aug 25, 2004 ... Current Developments in Future Planetary Probe Sensors: .... Data: Outgoing and incoming EIA RS-422 interface for serial data transmission (for electrical purposes only, .... Milos, et. al, Journal of Spacecraft & Rockets 1999 ...
The nicotinic acetylcholine receptor (AChR) controls signal transmission between cells in the nervous system. Abused drugs such as cocaine inhibit this receptor. Transient kinetic investigations indicate...Full Text Available
BackgroundPregnant women are more susceptible to severe Plasmodium falciparum malaria, which can lead to poor maternal and fetal outcomes. Few data exist on the...Full Text Available
We have developed a new strategy for immunization of wild rabbit populations against myxomatosis and rabbit hemorrhagic disease (RHD) that uses recombinant viruses based on a naturally attenuated field...Full Text Available
This document presented the results of a full-scale pile load tests conducted on helix pile foundations supporting power transmission towers in northern Manitoba. The site conditions were described along with pile installation and the performance of the foundations. The pile load tests were carried out in 2 different soil conditions, notably soft to firm clays and stiff high plastic clays with silt varves. The performance of the helix pile foundations were examined under axial compressive and axial tension (uplift) loading conditions. The results of the compressive load tests were presented in the form of load settlement curves while the results of the uplift load tests were presented in the form of load displacement curves. Both types of load tests in soft or stiff clays showed the suitability of helical pile foundations for power transmission lines in northern Manitoba. The cylindrical shear failure mechanism controlled the behaviour of ...
γ-Aminobutyric acid (GABA)-ergic transmission is critical for normal cortical function and is likely abnormal in a variety of neuropsychiatric disorders. We tested the in...Full Text Available
Giardiasis is recognized as a worldwide public health problem. Seroprevalence data from both the developing and developed world show high rates of carriage in populations at risk for fecal-oral transmission,...Full Text Available
BackgroundDiagnostic delay in patients with tuberculosis (TB) leads to ongoing TB transmission, higher mortality rates and increased patient and government health expenditure. Qualitative...Full Text Available
The purpose of this study was to assess the effect of a 735-kV transmission line on the electric and magnetic field exposures of people living at the edge of the line's right of way. Exposure of 18...Full Text Available
The goal of this project was to develop a new technology for preparing samples for transmission electron microscopy (TEM) on the basis of ion fine beam processing. For this purpose processes of ion-beam-assisted removal (sputtering), separation, sample handling and ion-beam-assisted chemical etching as well of system-inherent components were examined. As an alternative to a Ga-source a liquid-metal ion source based on a AuGeSi alloy was developed, characterised and used in the FIB 4400. [German] Aufgabe des Projektes war die Entwicklung einer neuen Technologie zur Probenpraeparation fuer die Transmissions-Elektronenmikroskopie (TEM) auf der Basis der Ionenfeinstrahlbearbeitung. Dazu wurden Prozesse der ionenstrahlgestuetzten Abtragung (Sputtern), der Abscheidung, des Probenhandling, des ionenstrahlgestuetzten chemischen Aetzens sowie systemeigener Komponenten untersucht. Als Alternative zur Ga-Quelle wurde eine Fluessigmetall-Ionenquelle auf ...
The primary mode of transmission of Helicobacter pylori, a human pathogen carried by more than half the population worldwide, is still unresolved. Some epidemiological data suggest...Full Text Available
BackgroundChronic wasting disease (CWD) of cervids is a prion disease distinguished by high levels of transmissibility, wherein bodily fluids and excretions are thought to play an...Full Text Available
The increased transmission and geographic spread of dengue fever (DF) and its more severe presentation, dengue hemorrhagic fever (DHF), make it the most important mosquito-borne viral disease of humans...Full Text Available
Parasite transmission generally exhibits some form of positive density dependence. Thus, as population density increases, so too does the per capita risk of becoming infected. Under...Full Text Available
Intestinal parasitic infections have been perceived as a public health problem in Seychelles for decades. A comprehensive strategy to reduce morbidity and, in the long term, transmission of intestinal...Full Text Available
Development of the Conawapa-Winnipeg power transmission complex in Manitoba includes five interrelated transmission and conversion facilities. Environmental and socio-economic assessment work done to date on one component of this system (the upgrading of the Southern Receiver System) is described. This system is composed of a network of high voltage transmission lines and station facilities serving power demand in Winnipeg and southern Manitoba. The upgrading involves three main elements: energizing a second 230 kV ac circuit on an existing tower line running from the proposed Riel Station site to the existing St. Vital Station; constructing a new double-circuit 230 kV tower line on the same existing right-of-way between St. Vital and the Riel site area; and installing an additional transformer and other necessary equipment at St. Vital and other stations affected by the upgrade. The environmental impacts of these projects ...
The neurotransmitter glutamate is released by excitatory projection neurons throughout the brain. However, non-glutamatergic cells, including cholinergic and monoaminergic neurons, express markers that...Full Text Available
Until 1990, in Tuscany, salt pollution of anti-salt insulators installed on high-tension transmission lines had led to rare breakdowns. On the contrary, in the last months of 1990, in most of Tuscany, following a strong libeccio wind coming from the Tyrrhenian Sea, and due to a long period of drought, salt deposits accumulated on the insulators of the high-voltage transmission lines (380 kV, 220 kV and 132 kV). This phenomenon not only took place in the coastal areas near Livorno, Pisa and Grosseto, but also in areas far away from the sea such as Florence, Prato, Arezzo and Siena. Following this, several high-tension lines, and whole sections of 380 kV electric stations went out of order, damaging the stations' equipment, insulators on the lines, and in particular porcelain insulators. The maintenance operations that were immediately undertaken consisted in washing operations, first focussed on stations, and then on lines. Several ...
Until 1990, in Tuscany, salt pollution of anti-salt insulators installed on high-tension transmission lines had led to rare breakdowns. On the contrary, in the last months of 1990, in most of Tuscany, following a strong libeccio wind coming from the Tyrrhenian Sea, and due to a long period of drought, salt deposits accumulated on the insulators of the high-voltage transmission lines (380 kV, 220 kV and 132 kV). This phenomenon not only took place in the coastal areas near Livorno, Pisa and Grosseto, but also in areas far away from the sea such as Florence, Prato, Arezzo and Siena. Following this, several high-tension lines, and whole sections of 380 kV electric stations went out of order, damaging the stations' equipment, insulators on the lines, and in particular porcelain insulators. The maintenance operations that were immediately undertaken consisted in washing operations, first focussed on stations, and then on lines. Several hundred men ...
Transmission electron microscopy analysis (TEMA) was used to analyze the bronchoalveolar lavage fluid (BALF) of 262 subjects occupationally exposed (OE) to nonfibrous mineral particles (NFMP) and 42...Full Text Available
Feed-forward (FF) artificial neural networks (ANN) and radial basis function (RBF) ANN methods were addressed for evaluating the lightning performance of high voltage transmission lines. Several structures, learning algorithms and transfer functions were tested in order to produce a model with the best generalizing ability. Actual input and output data, collected from operating Hellenic high voltage transmission lines, as well as simulated output data were used in the training, validation and testing process. The aims of the paper are to describe in detail and compare the proposed FF and RBF ANN models, to state their advantages and disadvantages and to present results obtained by their application on operating Hellenic transmission lines of 150kV and 400kV. The ANN results are also compared with results obtained using conventional methods and real records of outage rate showing a quite satisfactory agreement. The proposed ...
The purpose of this paper is to present an analysis of lightning fault detection, location and protection using numeric distance relays applied in high voltage transmission lines, more specifically in the 500 kV transmission lines of CEMIG (Brazilian Energy Utility) between the Vespasiano 2 - Neves 1 (short line - 23.9 km) and Vespasiano 2 - Mesquita (long line - 148.6 km) substations. The analysis was based on the simulations results of numeric distance protective relays on power transmission lines, realized in September 02 to 06, 2002, at Siemens AG's facilities (Erlangen - Germany), using Real Time Digital Simulator (RTDS{sup TM}). Several lightning faults simulations were accomplished, in several conditions of the electrical power system where the protective relays would be installed. The results are presented not only with the times of lightning faults elimination, but also all the functionality of a ...
The object of this research is the evaluation of the performance of ultra high speed relays (UHSR's) used for protection of a-c transmission lines. For purposes of this report, these are relays whose response time is less than a quarter of a cycle of the 60 Hz wave (i.e. 4.167 ms.). To identify relaying schemes that may comply with this definition, a literature survey was undertaken. The selected relays were studied in detail and modeled on a digital computer. A theoretical description of these relays is presented. Records of real transient data as well as of simulated data were used as input to the digital models of relays. The real data were recorded by means of monitoring stations connected to the Florida Power and Light Company transmission lines. The simulated data were obtained by modeling the relevant parts of the utility's transmission system using a University of British Columbia simplified ...
Distance protection, differential protection and directional comparison schemes are presently used for protecting transmission lines. Directional comparison relays are set to respond to faults in the protection zone without intentional time delay and are, therefore, used where high-speed fault clearing is needed. Artificial Neural Networks (ANNs) can handle most situations which cannot be defined sufficiently for finding a deterministic solution. The design and testing of an ANN for directional comparison protection of transmission lines are presented in this paper. Training patterns were generated using voltage and current samples for faults at various locations along a transmission line. The faults were simulated using an electromagnetic transient program and a sample three-phase power system. The performance of the proposed discriminator was checked using data simulated for testing and the fault data recorded from 240 kV ...
The lung of the lesser bushbaby (Galago senegalensis) has been investigated morphologically and morphometrically using the transmission and scanning electron microscopes. Grossly and microscopically,...Full Text Available
A high-speed fiber-based network for the transmission and display of digitized full-motion cardiac images has been developed. Based on Asynchronous Transfer Mode (ATM), the network is scaleable, meaning...Full Text Available
BackgroundInsecticide-based methods represent the most effective means of blocking the transmission of vector borne diseases. However, insecticide resistance poses a serious threat...Full Text Available
Antimalarial drugs will be essential tools at all stages of malaria elimination along the path towards eradication, including the early control or “attack” phase to drive down transmission...Full Text Available
The global acquired immunodeficiency syndrome (AIDS) pandemic is thought to have arisen by the transmission of human immunodeficiency virus (HIV-1)-like viruses from chimpanzees in southeastern...Full Text Available
New habitat-based models for spread of hantavirus are developed which account for interspecies interaction. Existing habitat-based models do not consider interspecies pathogen transmission,...Full Text Available
The 220 kV Ch{bar u}si Trunk Line, now transmitting a maximum of 300 MW of electricity between the Ch{bar u}goku area of Honsh{bar u} and Shikoku island, is expected to be inadequate in the 1990's due to the rise in electrical demand. Therefore, to strengthen this interconnection, a new 500 kV transmission line was proposed. The most significant feature of this transmission line is the installation of 500 kV cables along the bridges (the Seto Ohashi Bridge) which span the Inland Sea (Seto). This is the first 500 kV long-distance transmission cable line. It is also the first large-scale cable line in the world installed along various types of bridges (ten bridges; route length of the bridge portion approximately 8 km). This paper gives an outline of the Honsh{bar u}---Shikoku interconnecting transmission line and also presents some technical features concerning 500 kV cables.
The US Department of Energy, Division of Electric Energy Systems, has undertaken to identify the environmental issues and potential impacts associated with the installation of underground electric power transmission systems. This study reports the results of investigations into the advanced cable technologies being considered for future underground applications, as part of the development oriented research program of the Division of Electric Energy Systems. While the technology involves a high level of sophistication, there are relatively few impacts to the environment that are potentially significant, and of these none are inherently non-mitigable. Route planning, system design, and methods of construction and accident response can be pursued in order to minimize impacts where strict constraints are appropriate.
Thermal analysis testing revealed slight weight changes, which were a function of gamma irradiation, in a highly reduced Defense Waste Processing Facility (DWPF) simulated waste glass. Transmission electron microscopy (TEM) was performed on this glass to determine if the weight change corresponded to microstructural variations. TEM analyses showed that no microstructural changes were attributable to gamma irradiation. Exposure of the samples to the electron beam in the TEM did cause changes in the glass microstructures in some cases. These changes were likely due to localized heating of the glass due to interactions with the transmitted electrons.
Single and selective pole tripping schemes may be used to maintain a desired level of system integrity while minimizing transmission line expenditures. In general, these schemes will be most effective on those portions of the system where relatively few interconnections exist. While selective pole tripping may superficially appear to provide more margin than single pole schemes in the preservation of system stability, it seems unlikely that in those actual applications where single pole tripping is warranted that selective pole tripping will provide any significant advantages.
The power industry is moving toward the use of high-voltage transmission lines on tall, flexible towers. These towers are designed for heavier loadings than were previous towers, but the secondary effects of tower displacement tend to be ignored in the present day tower analysis. This paper examines the secondary effects from the large displacement of flexible towers, reviews the secondary stresses arising from joint rigidity and member continuity, and examines the reliability of tower strength predicted by the ASCE design guidelines. More realistic tower test acceptance criteria and a more reliable tower design methodology are suggested.
The first successful application of a new method to investigate phase transformations in real time, like the decomposition of austenite into bainite in grey iron, is described. During the ongoing transformation, transmission spectra of thermal neutrons, which contain Bragg edges corresponding to the crystal structure of the transforming phases, are recorded. By evaluating the height of these Bragg edges, which is a measure of the volume fraction of the phase, at different transformation times, the transformation can be followed in-situ in a time resolved manner. The method is compared to other previously used methods (micrographs, dilatometry, diffraction techniques); also a summary and an outlook are given. ((orig.))
The first successful application of a new method to investigate phase transformations in real time, like the decomposition of austenite into bainite in grey iron, is described. During the ongoing transformation, transmission spectra of thermal neutrons, which contain Bragg edges corresponding to the crystal structure of the transforming phases, are recorded. By evaluating the height of these Bragg edges, which is a measure of the volume fraction of the phase, at different transformation times, the transformation can be followed in-situ in a time resolved manner. The method is compared to other previously used methods (micrographs, dilatometry, diffraction techniques); also a summary and an outlook are given. ((orig.)).
There is strong interest in lithium imaging, particularly because of its significance in battery materials. However, light atoms only scatter electrons weakly and atomic resolution direct imaging of lithium has proven difficult. This paper explores theoretically the conditions under which lithium columns can be expected to be directly visible using annular bright field scanning transmission electron microscopy. A detailed discussion is given of the controllable parameters and the conditions most favourable for lithium imaging.
This paper describes the main aspects and results of the planning studies undertaken to evaluate the technical benefits of using Thyristor Controlled Series Compensation (TCSC), in a large 500 kV transmission system (Brazilian North-Northeast system). TCSC controllers design and simplified models for digital non-linear time domain simulations are discussed. The proposed controllers are tuned and used to support the comparative analysis between controlled and fixed series compensation. The relevant conclusions concerning this comparison are highlighted. (author) 2 refs., 14 figs., 3 tabs.
Due to development of electric power system and considering an increase of electrical energy consumption, needs for larger units in new power plants are obvious. Connection of large nuclear power plants to the grid, depending on their power and location, usually requires significant investments in transmission network development and construction. Considering the capacity of the 400 kV transmission network in Croatia, this problem is evident. This paper deals with the possibilities of nuclear power plants construction, as one possible option in electric power system development, and their interconnection to the electricity grid. (author).
Self-magnetically insulated, high-voltage transmission lines are used in inertial confinement fusion particle accelerators in order to transmit power from the vacuum insulator to the diode. This paper describes a time-dependent 2-D code (MITL) for calculating (for planar or triplate geometries) the motion of test electrons through the tapered input or output convolutes of such lines. MITL results show that the electron canonical momentum in the direction of the flow changes as the electron passes through the convoluted geometry; it is suggested that these electrons lead to losses observed in long self-magnetically insulated lines.
Typical receiver processing, targeting always the best achievable bit error rate performance, can result in a waste of resources, especially, when the transmission conditions are such that the best performance is orders of magnitude better than the required. In this work, a processing framework is proposed which allows adjusting the processing requirements to the transmission conditions and the required bit error rate. It applies a-posteriori probability receivers operating over multiple-input multiple-output channels. It is demonstrated that significant complexity savings can be achieved both at the soft, sphere-decoder based detector and the channel decoder with only minor modifications.
The author briefly discusses definition of terms, gives an introduction to measurement techniques and describes the characteristics of various low-frequency fields and their causes using typical examples: natural electric fields (thunderstroms), natural magnetic fields, technical electric constant fields (urban transportation, households), static magnetic fields (urban transportation, nuclear magnetic resonance imaging), technical electric alternating fields (high-voltage transmission lines, households), and magnetic alternating fields (high-voltage transmission lines). The author discusses both occupational exposure and that of the general public while underpinning his statements by numerous tables, measurement diagrams and charts. (Uhe).
This paper presents a unique method, currently under evaluation, that can continuously track pipeline operation providing essentially instantaneous responses to leaks or ruptures without causing a pressure drop or energy loss. Using the highly linear characteristics of a very accurate and repeatable meter and then correlating it to a second identical unit, a dynamic leak detection system is planned that can be retrofitted on existing pipelines without a major construction effort nor destroying the integrity of the existing transmission line. Initial tests performed on a crude oil transmission line verified the equipment's performance and established that the repeatability limits are sufficient to continue development of the concept.
This report describes the successful development of a computer program for the analysis of the economic, thermal, and rating characteristics of HPOF underground transmission cables with forced cooling. With this program cable engineers can interactively analyze self-cooled and forced-cooled HPOF cable design alternatives. The program computes cable thermal characteristics and discounted costs so that the impacts of changes in design parameters can be estimated. This report provides a review of the currently available HPOF design options that can be considered. The HPOF economic analysis program is written in FORTRAN IV and was developed for interactive operation.
The paper outlines the underlying physical mechanisms by which electric and magnetic fields exist, with particular reference to high voltage transmission lines. Epidemiological and laboratory studies are the two approaches used in research into the subject and the shortcomings and inconstancies in the results are mentioned. Recent epidemiological results are presented together with possible mechanisms between fields and the human body. Attention is drawn to the work of certain international and national bodies concerning the alleged association between electromagnetic fields and ill-health, and their conclusions are reported. Finally, the policy of the Electricity Supply Board in Ireland is outlined. 2 figs.
Results obtained on induced current and voltage caused by a high voltage transmission lines running parallel at a trolley bus contact lines, are presented. A computer program in Basic language, was developed to calculate the electric induction, problems of safety, a theoretical development and mathematical model of the electric factors between two lines (inductor and induced) are also discussed. 11 figs., 1 tab., 8 refs.
With the compensator-series equipment put into operation in 1992 - giving a performance of 330 Mvar - it was made possible for high-performance electronics to use a continuously variable, fully loaded power transmission line and to regulate the energy flow and minimise overcurrent losses. As well as these technical qualities, this system could offer environmental advantages for European implementation. This would avoid the need to plan and construct new high voltage transmission lines in order to meet increased demand. (orig.)
A probabilistic method for assessing the profitability of reactive power compensation devices such as capacitors, static VAR compensators and generators, which improve network security, was described. Since network development is limited by environmental constraints, power networks are operated close to their limits. Because of this fact transmission network planning increasingly relies on techno-economic models to improve network security and profitability. The proposed method consists of analyzing large numbers of constrained power system states, extracted from power system simulation exercises. The paper describes details of the method and provides an example of a numerical application on a part of the French power transmission system. 10 refs., 8 figs.
All-optical envelope detection of a 5 GHz 200 Mbit/s modulated radio frequency signal is achieved using a 650 nm resonant cavity light emitting diode. Error-free transmission is achieved over a 50 m-long link of 1 mm diameter graded index polymer optical fibre (POF). The presented system has potential applications in low cost and low complexity short range wireless and wireline POF-based transmission links.
The Fast Wave Current Drive (FWCD) system at DIII-D has increased its available radio frequency (RF) power capabilities with the addition of two new high power transmitters along with their associated transmission line systems. A Sun Sparc-10 workstation, functioning as the FWCD operator console, is being used to control transmitter operating parameters and transmission line tuning parameters, along with acquiring data and making data available for integration into the DIII-D data acquisition system. Labview, a graphical user interface application, is used to manage and control the above processes. This paper will discuss the three primary branches of the FWCD computer control system: transmitter control, transmission line tuning control, and FWCD data acquisition. The main control program developed uses VXI, GPIB, CAMAC, Serial, and Ethernet protocols to blend the three branches together into one cohesive system. The ...
As part of the licensing process to construct a new 230 kV transmission line on an existing right-of-way in Manitoba, an electrical effects study was conducted in 1998. The study was part of the environmental assessment program crucial in obtaining government approval to construct the line. Some residents living adjacent to the new transmission circuit expressed concerns about alleged adverse health effects associated with long-term exposure to magnetic fields from high voltage transmission lines. In order to verify the accuracy of the predicted magnetic field levels submitted to the regulatory body in the the electrical effects study and to instill confidence in the residents of the affected communities, a three-year magnetic monitoring project was conducted between 2003 and 2005 along the right-of-way after the new 230kV transmission line was energized by Manitoba Hydro. This paper described the ...
The object of this research is to study reactivity at superthermal collision energies using a fast neutral beam that is generated by photodetachment. Systems scheduled for initial study include basic oxygen-hydrogen reactions. Unfortunately, we can not yet report realization of this goal, but during this funding period we have made advances that are anticipated to lead to successful measurements during the next year. The parameters described below refer to the model system O + H{sub 2} {yields} OH + H. The basic design involves the collision of fast neutrals, created by photodetachment of the corresponding negative molecular ion, with a stable reactant gas in a collision cell. Products are detected by ionization and mass analysis. We are equipped to study rotational effects on reactivity by comparing results for rotational levels J = 0 and 1 of H{sub 2}. Highlights during the funding period are given in this report.
Image subtraction techniques, in conjunction with [75Se]selenomethionine (75Se) scintigraphy, have recently been suggested to be a potentially valuable tool for localization of parathyroid abnormalities. With use of these techniques, we prospectively studied 15 patients scheduled for parathyroid operations. Postoperatively, all were normocalcemic. Anterior scintiscans of the neck were divided into quadrants, and regions of enhanced uptake were assigned to one or more quadrants. On this basis, by chance alone a minimum of 25% of single-gland enlargements would be assigned to the correct quadrant of the neck. We found that by use of 75Se scanning only 8 of 22 abnormal glands (36%) were assigned to the quadrant of the neck in which they were found intraoperatively. In no case was a clearly visualized focus of parathyroid activity encountered. These results do not justify the continued use of 75Se scintigraphy with or without image subtraction in the preoperative ...
This ACDR was performed following completed of the Conceptual Design Report in July 1992; the work encompassed August 1992 to January 1994. Mission of the WRAP Module 2A facility is to receive, process, package, certify, and ship for permanent burial at the Hanford site disposal facilities the Category 1 and 3 contact handled low-level radioactive mixed wastes that are currently in retrievable storage at Hanford and are forecast to be generated over the next 30 years by Hanford, and waste to be shipped to Hanford from about DOE sites. This volume provides an introduction to the ACDR process and the scope of the task along with a project summary of the facility, treatment technologies, cost, and schedule. Major areas of departure from the CDR are highlighted. Descriptions of the facility layout and operations are included.
Background:- Only one study has used a prospective method to analyze the diagnostic stability of first psychotic episodes in children and adolescents. The Child and Adolescent First-Episode Psychosis Study (CAFEPS) is a 2-year, prospective longitudinal study of early-onset first episodes of psychosis (EO-FEP). Aim:- To describe diagnostic stability and the variables related to diagnostic changes. Methods:- Participants were 83 patients (aged 9-17-years) with an EO-FEP consecutively attended. They were assessed with a structured interview (Kiddie-Schedule for Affective Disorders and Schizophrenia, Present and Lifetime version) and clinical scales at baseline and after 2-years. Results:- The global consistency for all diagnoses was 63.9%. The small group of bipolar disorder had high stabilit...
The ROP margin in a CANDU reactor is decreasing over time due to the Primary Heat-Transport System (PHTS) aging effect. Adjustment of the ROP trip setpoint is required to maintain a high trip-probability and ROP trip effectiveness. Especially, for Wolsong-1, which is scheduled to change the old pressure tubes in 2009, the trend of ROPT after the retubing should be reevaluated. Before setting a ROPT, the main thermal characteristics including Critical Channel Power (CCP) should be calculated by the NUCIRC code. In this paper, the thermalhydraulic evaluation for Wolsung-1 was conducted with the updated Wolsung-1 PHTS data. Specifically, for the case of 0 EFPY (Effective Full Power Year) and 11 EFPY after the retubing, the distribution of the channel flow rate, channel exit quality, critical channel power, and critical power ratio (CPR) of the Wolsong-1 aged plant are calculated
The Linac Coherent Light Source (LCLS) is a SASE x-ray Free-Electron Laser (FEL) based on the final kilometer of the Stanford Linear Accelerator. Such an FEL requires a high energy, high brightness electron beam to drive the FEL instability to saturation. When fed by an RF-photocathode gun, and modified to include two bunch compressor chicanes, the SLAC linac will provide such a high quality beam at 14 GeV and 1-{micro}m normalized emittance. In this paper, we report on recent linac studies, including beam stability and tolerances, longitudinal and transverse feedback systems, conventional and time-resolved diagnostics, and beam collimation systems. Construction and installation of the injector through first bunch compressor will be completed by December 2006, and electron commissioning is scheduled to begin in January of 2007.
The intermediate silicon layers detector (ISL) was proposed as a part of the upgraded CDF detector at the RUN-II of the Tevatron mean value of pp collider at Fermilab, scheduled to start in year 2000. The ISL is a large-radius (20-30 cm) silicon tracker with a total active area of about 3.5 m. Located in the region between the silicon vertex detector and the central outer tracker, the ISL will allow tracking in the forward region and significantly improve it in the central area. Together with the SVX II the ISL forms a standalone, 3D silicon tracker. The challenge is to build a low-cost device which provides precise 3 D tracking in a approximately equal to 2 m long area with a minimal amount of material for the supporting structure. The conceptual design and the status of the project are reviewed.
The Authenticated Tracking and Monitoring System (ATMS) has been designed to address the need for global monitoring of the status and location of proliferation-sensitive items. Conceived to utilize the proposed Global Verification and Location System (GVLS) satellite link, ATMS could use the existing International Maritime Satellite commercial communication system until GVLS is operational. The ATMS concept uses sensor packs to monitor items and environmental conditions, collects a variety of events data through a sensor processing unit, and transmits the data to a satellite, which then sends data to ground stations. Authentication and encryption algorithms will be used to secure the data. A typical ATMS application would be to track and monitor the safety and security of a number of items in transit along a scheduled shipping route. This paper also discusses a possible proof-of-concept system demonstration.
The H-Coal ebullated bed reactor contains at least four discrete components: gas, liquid, catalyst, and unconverted coal and ash. Because of the complexity created by these four components, it is desirable to understand the fluid dynamics of the system. The objective of this program is to establish the dependence of the ebullated bed fluid dynamics on process parameters. This will permit improved control of the ebullated bed reactor. Progress has been made in the study undertaken for defining the hydrodynamic properties of gas/liquid/solid systems as related to the H-Coal process. The literature search was completed, and a report will be issued shortly. Design and construction of the fluid dynamics unit proceeded as planned. Unit completion is scheduled for May 1, 1978.
The Low Power and Shutdown (LPSD) PRA (Probabilistic Risk Assessment) Standard (ANS-58.22) is currently being drafted by a Writing Group under the auspices of the Risk Informed Standards Committee of the American Nuclear Society (ANS). The Writing Group includes representatives from nuclear utilities, US Nuclear Regulatory Commission (NRC), national laboratories, universities, and consultants with substantial experience producing LPSD PRAs. This draft standard is scheduled to be released for public comment in the second quarter of 2004, with publication by the end of 2004. The LPSD PRA Standard is based on a mature technology that shares many requirements with full power PRAs. It will provide specific methods and criteria whereby PRAs of appropriate quality and scope can be used in the conduct of plant decision-making and other activities, including addressing NRC requirements. This paper presents the current status of this standard.
Overall architecture of a local computer network, STAR, is described. The objective is to accomplish a cost-effective system which provides multiple users a real-time service of manipulating very large volume imagery information and data. STAR consists of a reconfigurable communication subnet (starnet), heterogeneous resource units, and distributed-control software entities. Architectural aspects of a fault-tolerant communication subnet, distributed database management, and a distributed scheduling strategy for configuring desirable computation topology are exploited. A model for comparing cost-effectiveness among starnet, crossbar, and multiple buses is included. It is concluded that starnet outperforms the other two when the number of units to be connected is larger than 64. This project serves as a research tool for using current and projected technology to innovate better schemes for parallel image processing. 30 references.
The Electric Power Research Institute has published a report for planners, designers, owners, and operators of hydroelectric pumped-storage plants that records the operation and maintenance knowledge of 35 domestic and foreign pumped-storage projects. The report provides a comprehensive record of practices that have reduced forced outages and shortened scheduled repairs. As time passes and experienced staff retire at pumped-storage plants, many O M lessons are lost. To remedy that situation, EPRI commissioned Morrison-Knudsen Engineers Inc. to prepare a special report. The 348-page publication records the accumulated civil, geotechnical, mechanical, and electrical O M knowledge and experiences of pumped-storage plant staff. It also includes recommendations to planners and designers of future pumped-storage plants and concludes with descriptions of O M experiences reported by plant operators and utility representatives.
The efficient design of computation intensive multidimensional signal processing applications requires dealing with three kinds of constraints: those implied by the data dependencies, the non-functional requirements (real-time, power consumption) and resources availability of the execution platform. Modeling and Analysis of Real-time and Embedded systems (MARTE) UML profile through its repetitive structure modeling (RSM) package is well suited to model the inherent parallelism within these applications, a compact representation of parallel execution platforms and the distributive mapping of one on another. The execution of such a specification respects the whole set of constraints defined upon, while the quality of the scheduling is directly linked to the quality of the mapping of the mult...
This report summarizes the activities carried out by Aspen Systems Corporation in support of the Department of Energy's Rebuild America program during the period from October 9, 1999 to October 31, 2004. These activities were in accordance with the Scope of Work contained in a GSA MOBIS schedule task order issued by the National Energy Technology Laboratory. This report includes descriptions of activities and results in the following areas: deployment/delivery model; program and project results; program representative support activities; technical assistance; web site development and operation; business/strategic partners; and training/workshop activities. The report includes conclusions and recommendations. Five source documents are also provided as appendices.
After the successful completion of the development program of the 2000 m water depth HVDC Hawaii Deep Water Self Contained Fluid Filled Cable, the interconnection between Hawaii island and Oahu island is examined. Thermal, electrical, mechanical, hydraulic, corrosion, length aspects are developed for both fluid filled and paper impregnated (SOLID) cables which are foreseen in different portions of the approximately 250 km length connection. Considerations are also presented for the requirements of the cable ship: 12 m sheave diameter, 7000 t capacity for the rotating platform. The feasibility of manufacturing, transporting and laying such cables within a practical schedule is discussed in this paper.
Purpose The primary objective of this sub-study, undertaken as an extension to the previously reported phase-I study, was to explore the feasibility, tolerability and pharmacokinetics (PK) of belinostat when administered by the oral route. Preliminary pharmacodynamic (PD) studies were also performed to enable comparison of the biological effects of the oral and intravenous formulations. Patients and methods Oral belinostat was administered in a range of doses and schedules (once, twice or thrice daily), on either day 1 or days 1?5, of the second or a subsequent treatment cycle in 15 patients who were included in the phase-I trial of intravenous belinostat. Serial blood samples were collected for PK and PD (histone acetylation) analyses, and the results compared with corresponding analyses ...
This report summarizes the 1981 operating and test data obtained at the six ton per day Advanced Coal Liquefaction Research and Development Facility in Wilsonville, Alabama. Special emphasis is placed on data accumulated during the fourth quarter of 1981. The Wilsonville R and D Facility was in operation 71% of 1981 (70% of the fourth quarter) with scheduled shutdowns accounting for 23% of the downtime (28% during the fourth quarter). Kentucky 9 coal from the Fies mine was processed in all runs conducted during 1981 (Runs 222 through 235). The hydrotreater (HTR) unit was brought on stream successfully in May 1981. The three process units of the Wilsonville facility were operated in a non-integrated mode during the second half of 1981. Significant data was obtained and is summarized.
MINER?A is a high resolution, fully active detector designed to study neutrino interactions on nuclei in the NuMI beam at Fermi National Accelerator Laboratory. The active volume of the detector consists of 3 tons of plastic scintillator and includes embedded targets of 4He, C, H2O, Fe and Pb. The MINER?A collaboration expects to perform precision, A-dependent neutrino cross section measurements in the 1?10 GeV region, measure the axial form factor, and study nuclear shadowing of F2, quark-hadron duality and coherent pion production, among other topics. MINER?A began data taking in the fall of 2009. This paper describes the MINER?A experiment and provides an overview of the physics objectives along with estimated uncertainties of the measurements and the tentative projected schedule of dat...
The use of selective additives such as MgO as a sintering aid and a rare earth oxide as a grain growth inhibitor, has allowed the manufacture of beryllia ceramics having close to theoretical density. The grain size and grain size distribution can be controlled by an optimum firing schedule leaving a remnant porosity which is extremely fine (0.2 {mu}m). This structure is compared with conventional BeO ceramics, densified by liquid phase sintering, which develops a glassy grain boundary and retains large pores up to 3 {mu}m. The significantly improved strength properties, extremely fine pores,the 'pinning effect' of rare earth oxide, and the superior surface finish both in the as-fired and polished state are discussed in relation to the micro-structure. (orig.).
This brochure describes the strategy employed by the administration of Malaspina University--College in Nanaimo, British Columbia, to implement energy-efficient plans and integrating systems and plans that would allow the institution to consume less energy, fewer resources and improve the health and well-being of its students and staff. An assessment study to identify the most problematic areas, and to develop a prioritizing strategy for their replacement was the first step, followed by rigorous adherence to a 10- year cyclical replacement schedule. The program includes replacement of rooftop ventilation units, installation of high-performance glazing units to replace single-glazed windows, implementation of an Energy Management System to monitor heating, ventilating and air conditioning systems, and a Power Smart New Building Design and Building Improvements Program. The combined cost avoidance associated with these projects is estimated to reach $ 4.3 million ...
An 80 keV, 3.6 MW neutral beam injection system has recently been installed on Doublet III, and the installation of a second system is scheduled within several months. Armor plate consisting of /approximately equals/100 graphite tiles (10 cm x 10 cm) coated with TiC has been plated over portions of the inner vacuum wall lying in the line of sight of the ion sources. In order to monitor the condition of the armor plate an infrared camera and a set of optical pyrometers have been installed alongside the beamline and view the armor plate through a CaF/sub 2/ window. The pyrometers measure the temperature of the armor plate associated with the maximum of the intensity distribution of each ion source.
A large portion of the work performed at nuclear power plants follows standardized flow paths. For example, although components on which the maintenance crew works differ from one assignment to the next, all assignments basically follow the same process: requesting, reviewing, planning, scheduling, executing, testing, and documenting the work. In general, the term open-quotes work processclose quotes is used to refer to a standardized sequence of tasks designed within the operational environment of an organization to achieve a specific goal. The predictable nature of work processes suggests that a systematic analysis can be conducted to identify the desirable design of the process and to develop performance measures with respect to the strengths and weaknesses in the process. Furthermore, because of the close relationship of the work process to plant performance and plant safety, it is believed that such an analysis will facilitate the inclusion of organizational ...
The purpose of this project is to demonstrate targeted infill and extension drilling opportunities, better determinations of oil-in- place, methods for improved completion efficiency and the suitability of waterflooding in certain shallow-shelf carbonate reservoirs in the Williston Basin, Montana, North Dakota and South Dakota. Improved reservoir characterization utilizing 3-dimensional (3D) and multi-component seismic are being investigated for identification of structural and stratigraphic reservoir compartments. Field demonstrations are in progress to collect data for evaluation of horizontal completions in both the Red River and Ratcliffe. A vertical well in the Red River will test attribute analysis of 3D seismic data for prediction of porosity development. Additional seismic acquisitions and interpretation are in progress for both the Ratcliffe and Red River. A water-injectivity test in a new horizontal completion in the Red Rive B zone at Buffalo Field is ...
In this paper we present an overview of the literature on efficacy and safety trials of the various pneumococcal conjugate vaccines on the market (PCV7) and in development (PCV9, PCV11 and allegedly PCV10 and PCV13), as well as of observations from post-licensure studies. Seven- (PCV7) and nine-valent PCV (PCV9) are reported to be sufficiently immunogenic after administration of a 3+1 schedule in infants in various RCTs. PncOMPC (PCV7 with a protein of N. meningitidis as a carrier) is less immunogenic, though this may have no repercussions for the protective efficacy against clinical disease. PCV7 is 82-97% efficacious against vaccine serotype (VT) IPD, 90% efficacious against (clinically diagnosed) pneumococcal pneumonia, and, like the 11-valent PCV, 57% efficacious against VT acute otiti...
This report discusses the procedures that establish the configuration control processes for the Hanford Environmental Information System (HEIS) software. The procedures also provide the charter and function of the HEIS Configuration Control Board (CCB) for maintaining software. The software configuration control items covered under these procedures include the HEIS software and database structure. The configuration control processes include both administrative and audit functions. The administrative role includes maintaining the overall change schedule, ensuring consistency of proposed changes, negotiating change plan adjustments, setting priorities, and tracking the status of changes. The configuration control process audits to ensure that changes are performed to applicable standards.
The Electric Fuel zinc-air battery yielded energy densities from 6.8 to 10.2 times higher than those of the lead-acid batteries. The higher the power and the more difficult the driving cycle, the higher this ratio of energy densities grew. Not only was the Electric Fuel battery capable of extended high-power discharge, the impact of such discharge conditions on energy and driving range was show to be quite small, and was much smaller than the comparable impact on lead-acid traction batteries. At the time of writing this paper, tests are scheduled to continue with the 110-kWh battery in the Mercedes van, and preliminary plans have been made for testing of additional batteries on other vehicle types.
The use of Floating Production Storage and Offloading (FPSO) vessels to develop UK offshore oil fields looks certain to increase. Of the 64 new offshore fields due for development in the next few years, 15 are expected to use FPSO vessels for their production. Most of these are small, short-life fields in the central North Sea which would not justify investment in a fixed platform. Three, however, are large fields west of Shetland, and one, the Foinaven field, is scheduled to be the first commercial development in this area, perhaps setting a precedent. Floating production systems with substantial storage capacity can be the best option in deepwater locations which are remote from existing infrastructure, where the cost of an export pipeline would be prohibitive. (author)
This paper reports that there are four combustion technologies upon which U.S. electric utilities are expected to rely for the majority of their future power generating needs. These technologies are pulverized coal- fired combustion (PC); coal-fired fluidized bed combustion (AFBC); coal gasification, combined cycle systems (CGCC); and natural gas-fired combined cycle systems (NGCC). The engineering and economic parameters which affect the choice of a technology include capital costs, operating and maintenance costs, fuel costs, construction schedule, process risk, environmental and site impacts, fuel efficiency and flexibility, plant availability, capacity factors, timing of startup, and the importance of utility economic and financial factors.
The economic benefits of supplemental fuel injections depend, in part, on the coke replacement ratio. An assessment of the accuracy with which blast furnace coke rate may be measured and a determination of the key drivers of coke rate uncertainty are offered, to provide guidance for experiments in high-rate gas injection. Using statistical analysis tools, an expression for the measurement error associated with the various terms of blast furnace carbon balance is developed. Coke rate calculations based on the material balance are most sensitive to coke carbon content and to proper tracking of hot metal tapping schedule.
A pipeless batch plant is a batch processing production system using mobile vessels. The plant performances depend on both hardware of equipment and software of operation. So the plant includes many design factors such as number of vessels, stations and AGVS, layout of stations, vessel moving rules, job scheduling and so on. In this paper, the characteristics of pipeless batch plant design are considered to handle the problem by the systems engineering approach. Then, a practical design method known as design-by-analysis is applied to solve such a complex design problem. Based on this concept, a design support system composed of modeling, simulation and evaluation subsystems is developed. This system enables rational decision making through performance evaluation for proposed design of a pipeless batch plant. The usefulness of the system is illustrated by industrial examples. 12 refs., 8 figs., 6 tabs.
With the ever increasing awareness of the toxicity of Pb, significant pressure has been put on the electronics industry to get the Pb out of solder. This work pertains to the development and characterization of an alloy which is Pb-free, yet retains the proven positive qualities of current Sn-Pb solders while enhancing the shortcomings of Sn-Pb solder. The solder studied is the Sn-4.7Ag-1.7Cu wt% alloy. By utilizing a variety of experimental techniques the alloy was characterized. The alloy has a melting temperature of 217{degrees}C and exhibits eutectic melting behavior. The solder was examined by subjecting to different annealing schedules and examining the microstructural stability. The effect of cooling rate on the microstructure of the solder was also examined. Overall, this solder alloy shows great promise as a viable alternative to Pb-bearing solders and, as such, an application for a patent has been filed.
This paper will provide an overview of the Common Aperture Multispectral Sensor (CAMS) Hardware Demonstrator. CAMS is a linescanning sensor that simultaneously collected digital imagery over the Far-IR (8 to 12 {mu}m) and visible spectral (0.55 to 1.1 PM) spectral bands, correlated at the pixel level. CAMS was initially sponsored by the U.S. Naval Air System Commands F/A-18 program office (PMA-265). The current CAMS field tests are under the direction of Northrop-Grumman for the Defense Nuclear Agency (DNA) in support of the Follow-On Open Skies Sensor Evaluation Program (FOSEP) and are scheduled to be conducted in April 1996. 8 figs., 4 tabs.
A combination of erosion and corrosion at the Victoria Junction coal preparation plant in Sydney, Nova Scotia was causing serious problems. Schedule 80 mild steel pipes were starting to fail as well as some quarter-inch steel plates in the lauders and chutes. Some corrosion tests were carried out and the high chloride level in the process water was felt to be the single most important contribution to the corrosion problem. Cast basalt was selected as a solution to the pipe wear problem. Three different types of abrasion/corrosion-resistant tiling - basalt tiles, kalceram tiles and ceramic tiles were well suited to the chloride conditions at this plant.
On March 31, 1995, the US Department of Energy filed a draft application for certification of compliance with the US Environmental Protection Agency (USEPA) to show the Waste Isolation Pilot Plant's compliance with the USEPA's environmental standards, making the application the first of its kind. Demonstration of compliance is by performance assessment. This paper is an early review of the performance assessment in the draft application, by the Environmental Evaluation Group, an oversight group. The performance assessment in the draft application is incomplete. Not all relevant scenarios have been analyzed. The calculation of potential consequences often does not use experimental data but rather estimates by workers developing additional data. The final compliance application, scheduled for October 1996 needs to consider additional scenarios, and be fully based on experimental data.
Various theories and examples of modelling, forecasting and optimization designing in the different parts of the petroleum and gas industries are presented, stochastic programming for long term planning in the refining industry, stochastic model for gasoline blending, feedstock optimization, location and sizing for offshore platforms, hydrocarbon exploration simulation rapid method, valuation of oil field development leases, economic models for petroleum allocation, models for oil supply market, trade embargo game theory, stochastic programming of gas contract portfolio management, scheduling transportation of oil and gas, strategic planning in an oil pipeline company, simulation of offshore oil terminal systems, hierarchical selection of oil and gas distribution systems.
The Advanced Neutron Source will be a new world-class facility for research using hot, thermal, cold, and ultra-cold neutrons. The heart of the facility will be a 330-MW (fission), heavy-water cooled and heavy-water moderated reactor. The reactor will be housed in a central reactor building, with supporting equipment located in an adjoining reactor support building. An array of cold neutron guides will fan out into a large guide hall, housing about 30 neutron research stations. Appropriate office, laboratory, and shop facilities will be included to provide a complete facility for users. The ANS is scheduled to begin operation at the Oak Ridge National Laboratory early in the next decade. This PDR document defines the plant-level requirements for the design, construction, and operation of ANS. It also defines and provides input to the individual System Design Description (SDD) documents. Together, this PDR document and the set of SDD documents will define and ...
We present in this article a detailed quantitative discussion of the measurement of the leptonic mixing angle theta_13 through currently scheduled reactor neutrino oscillation experiments. We thus focus on Double Chooz (Phase I & II), Daya Bay (Phase I & II) and RENO experiments. We perform a unified analysis, including systematics, backgrounds and accurate experimental setup in each case. Each identified systematic error and background impact has been assessed on experimental setups following published data when available and extrapolating from Double Chooz acquired knowledge otherwise. After reviewing the experiments, we present a new analysis of their sensitivities to sin^2(2 theta_13) and study the impact of the different systematics based on the pulls approach. Through this generic statistical analysis we discuss the advantages and drawbacks of each experimental setup.
Motion Camouflage (MC) is illuminated as a novel strategy in counterattacking anti-satellite by way of stealth trajectory scheduling. The dynamics model of MC in space is developed and a quadratic function with three boundary constraints is employed for trajectory determination. Based on the model a scenario is set to run the simulation. The results indicate given the designed acceleration input, the predator will be moved following a prescribed route, which precisely locates the predator between two objects at each time instant. In the last approaching phase, the motion is achieved with a big bumping rate which guarantees the power of this striking. Methods for deriving minimum fuel cost in the fixed approaching duration and the minimum approaching duration in limited acceleration input are proposed and are verified in the simulation. At last, camouflage is recognized as a multi-faceted affair, in which stealth trajectory design is considered an effective ...
Background and aims. The multiplicity of vaccine injections during childhood leads to iterative painful and stressful experiences which may lead in turn to anticipated pain and then possibly to a true needle phobia. We aimed at evaluating a multifactorial strategy of pain management combining pharmacological and non-pharmacological approaches during vaccination, as compared to usual care, in 4- to 12-year-old children. Methods. In all, 239 children were enroled by 25 family practitioners in an open-label study. After a pseudo-randomization, usual pain management (n = 132) was compared to a multifactorial strategy (n = 107) associating preliminary application of an anesthesic patch, preferential use of specified vaccines, child education by the parents and the doctor, parental accompaniment...
Positron emission tomography (PET) is a fully quantitative technology for imaging metabolic pathways and dynamic processes in vivo. Attenuation correction of raw PET data is a prerequisite for quantification and is typically based on separate transmission measurements. In PET/CT attenuation correction, however, is performed routinely based on the available CT transmission data. Recently, combined PET/magnetic resonance (MR) has been proposed as a viable alternative to PET/CT. Current concepts of PET/MRI do not include CT-like transmission sources and, therefore, alternative methods of PET attenuation correction must be found. This article reviews existing approaches to MR-based attenuation correction (MR-AC). Most groups have proposed MR-AC algorithms for brain PET studies and more recently also for torso PET/MR imaging. Most MR-AC strategies require the use of complementary MR and transmission images, ...
Transmission line faults must be located accurately to allow maintenance crews to arrive at the scene and repair the faulted section as soon as possible. Rugged terrain and geographical layout cause some sections of power transmission lines to be difficult to reach. In the past, a variety of fault location algorithms were introduced as either an add-on feature in protective relays or stand-alone implementation in fault locators. In both cases, the measurements of current and voltages were taken at one terminal of a transmission line only. Under such conditions, it may become difficult to determine the fault location accurately, since data from other transmission line ends are required for more precise computations. In the absence of data from the other end, existing algorithms have accuracy problems under several circumstances, such as varying switching and loading conditions, fault infeed from the ...
Sixty-Hz magnetic field exposures were measured for 45 adult residents of Maine. Thirty of the subjects resided near rights-of-way (ROWs) with either 345- and 115-kV transmission lines, or ROWs with only 115-kV transmission lines; fifteen resided far from any transmission lines. Personal exposure data for a single 24-hour period was acquired with the EMDEX. The EMDEX's event-marker button was used to partition exposures into Home and Away components. Also, three area measurements were taken for each subject during the personal exposure measurement period: (1) 24-hr fixed-site bedroom measurement with a second EMDEX; (2) Spot measurements in at least three rooms of every residence; and (3) Spot measurements outside each residence. Residence near transmission lines highly loaded during the measurement period was associated with increased Home and Total exposure relative to a far-away population. ...
Populations living close to high-voltage transmission lines often have residential magnetic field exposures in excess of 1 [mu]T, and sometimes over 2 [mu]T. Yet, populations studied in most epidemiologic investigations of the association between residential magnetic field exposure and cancer typically have exposures below 1 [mu]T and frequently below 0.5 [mu]T. To improve statistical power and precision, it would be useful to compare high exposure populations with low exposure population. Toward this end, we have developed an automated method for identifying populations living near high-voltage transmissions lines. These populations likely have more highly exposed individuals that the population at large. The method uses a geographic information system (GIS) to superimpose digitized transmission line locations on U.S. Census block location data and then extract relevant demographic data. Analysis of data from a pilot study ...
This report presents information obtained during five different studies of field effects from high voltage transmission lines performed at EPRI's High Voltage Transmission Research Center. The first study is the development of a methodology for the evaluation of the expected frequency of occurrence of specific short-term effects of spark discharges and induced currents caused by overhead high voltage transmission lines. The methodology is divided into the analysis of the expected frequency of occurrence of situations in which induction effects may occur, and the analysis of the expected severity of the effect. The second study is of the electric field in the surface and on the immediate proximity of the strands of stranded conductors used for overhead high voltage lines. In particular, the cases of deformations of stranded conductors, caused by air expansion or by popped out strands, are analyzed for the purpose of ...
The study of audible noise from high voltage transmission lines and a high voltage transformer station was conducted in three parts. Part 1 consisted of long-term measurement and statistical analysis by computer reduction of audible noise as a result of corona discharge from high voltage transmission lines and the associated weather conditions which contribute to this noise. Recommendations are given concerning further computer programming in order to improve the statistical reliability of corona noise presence and reduce the degree of background noise contamination of the present results. Part 2 consisted of categorizing and cataloguing of corona noise spectra from long-term measurements on 550, 735 and 765 kV transmission lines and to provide a library of such sounds on magnetic tape to be used in the ongoing study of corona noise. Twenty-five different corona sound spectra have been identified and documented in a tape ...
Power quality problems are caused by activities normal to utility operations such as maintenance outages and capacitor switching or events that are abnormal such as lightning strikes and equipment failures. Disconnection and reconnection of transmission lines and transformers can cause switching surges, and are more severe on extra high voltage transmission lines than high voltage lines. Capacitor switching can cause transients and harmonics that may affect sensitive equipment, and are the source of 3rd, 5th, 7th and 9th harmonics in the hundreds of hertz ranges. Overload, sudden loss of generating capacity and transmission line faults are typical problems affecting system stability. Fault interruptions and reclosings can cause surges in the distribution system, and lightning strikes may cause voltage surges or dips due to arrester sparkover. Blackouts, brownouts, voltage fluctuations, travelling wave overvoltages, ...
The contents of this report covers: (1) development of optimal geometries for crowned helical gears; (2) a method for their generation; (3) tooth contact analysis (TCA) computer programs for the analysis of meshing and bearing contact of the crowned helical gears; and (4) modelling and simulation of gear shaft deflection. The developed method for synthesis was used to determine the optimal geometry for a crowned helical pinion surface and was directed to localize the bearing contact and guarantee favorable shape and a low level of transmission errors. Two new methods for generation of the crowned helical pinion surface are proposed. One is based on the application of a tool with a surface of revolution that slightly deviates from a regular cone surface. The tool can be used as a grinding wheel or as a shaver. The other is based on a crowning pinion tooth surface with predesigned transmission errors. The pinion tooth surface can be generated by ...
Superconducting magnetic energy storage (SMES) is an emerging technology with features that are potentially attractive in electric utility applications. This study evaluates the potential for SMES technology in the generation, transmission, distribution, and use of electric energy; the time frame of the assessment is through the year 2030. Comparisons are made with other technology options, including both commercially available and advanced systems such as various peaking generation technologies, transmission stability improvement technologies, and power quality enhancement devices. The methodology used for this study focused on the needs of the market place, the capabilities of S and the characteristics of the competing technologies. There is widespread interest within utilities for the development of SMES technology, but there is no general consensus regarding the most attractive size. Considerable uncertainty exists regarding the eventual ...
In the Hokuriku area along the coast of the Japan Sea, thunderstorms often occurred not only in summer but also in winter, and this resulted in the shutdown of electricity supply or damage of equipment. This study was concerning the observation of the lightning channels in the Hokuriku area through a year by many still cameras equipped with liquid-crystal shutters. The following conclusions were obtained: Among 165 lightning incidents photographed during 2 years, there included 172 incidents of the falling thunderstorms and 23 incidents of simultaneously falling thunderstorms at multi-area. In the case of winter, frequency to occur simultaneously falling thunderstorms at multi-area was higher and the upward falling thunderstorms were more. There was a tendency that the duration time of the lightning current in winter was longer than in summer. In winter, frequency to occur the upward falling thunderstorms was higher, about 61% of the upward falling thunderstorms rose from the ...
The use of excitation system controls, specifically the Power System Stabilizer (PSS), to improve damping of power system oscillations and thus extend steady-state stability limits has been a subject of great interest in recent years. The desire to more fully utilize transmission capacity led to the installation of PSS controls on greater numbers of generating units to maintain stability margins. This paper addresses the tuning and adjustment of PSS controls in a two unit power plant. Both analytical studies and field test confirmations are presented. The practical difficulties of verifying the PSS control loop gain margin by testing are explored. A simplified procedure is outlined. The Lower Colorado River Authority (LCRA), Fayette Power Project (FPP) consists of two 683.7 MVA tandem compound steam turbine driven generators. The excitation systems are of the alternator rectifier type and the PSS control utilizes shaft speed as an input signal. The units must ...
Gas transmission pipelines are susceptible to both internal (gas side) and external (soil side) corrosion attack. Internal corrosion is caused by the presence of salt laden moisture, CO{sub 2}, H{sub 2}S, and perhaps O{sub 2} in the natural gas. Internal corrosion usually manifests itself as general corrosion. However, the presence of chlorides in entrained water also can lead to pitting corrosion damage. The electrochemical noise technique can differentiate general from localized corrosion and provide estimates of corrosion rates without external perturbation of the corroding system. It is increasingly being applied to field and industrial installations for in situ corrosion monitoring. It has been used here to determine its suitability for monitoring internal and external corrosion damage on gas transmission pipelines. Corrosion measurements were made in three types of environments: (1) aqueous solutions typical of those found within gas ...
Pd was deposited onto Si (111) 7x7 surface at approximately 700 K inside an ultrahigh vacuum transmission electron microscope. Plan-viewed transmission electron microscopy (TEM) observation indicated that the islands have two kinds of shapes, round and rectangular (one-dimensional) ones. In a diffraction pattern for the rectangular islands, extra spots along the <110> direction of the Si surface, spacing of which is 1/8 times as long as that of Si (220) spots, were seen. A high resolution TEM image showed the corresponding superstructure in the rectangular islands. In situ observation of the growing process of the rectangular islands showed repeat of introduction and relief of strains during the growth, suggesting that such superstructure would be constructed by stacking compositionally different phases or introducing defects so that the periodically maximized strain is relieved.
A field study was conducted in Ontario to evaluate the suitability of grouted piles for transmission tower foundations. The grouted piles were assessed in terms of the installation procedure and its foundation performance subjected to uplift loads. Two types of grouted piles, the H-pile and the pipe-pile, were evaluated and compared with conventional ungrouted H-pile foundations. Difficult soil conditions were encountered consisting of a deep deposit of loose to compact sand with a high water table. Both the grouted pipe-pile and the grouted H-pile developed uplift capacities more than double that of the conventional H-pile with the same embedment length at the test site. The grouted H-pile is recommended as a viable transmission line foundation in weak soils due to the significant improvement in its foundation performance, with minor modifications to the construction procedure. 3 refs., 17 figs., 12 tabs.
The coherent interaction of femtosecond laser pulses and a thin CdSe sample is investigated both experimentally and theoretically. Observation of coherent phenomena in semiconductors is very rare because the incoherent processes occur in the femtosecond time domain in these materials. One example of such a phenomena is the so called optical Stark effect of exciton where a blue shift of the exciton resonance occurs as a result of pumping below the bandgap. The coherent effects involving band-to-band and also exciton transitions. Using femtosecond transmission measurements clear evidence was observed for coherent interference effects of the light field and the driven material polarization. These interferences manifest themselves as oscillatory structures in the differential transmission spectra. The oscillatory features are explained by comparison with a semiclassical theory. Examples of the computed results are presented for different time ...
The application of HVDC system to the trunk power supply system requires the transmission of DC power as much as possible to improve the stability of the whole AC/DC system. To meet this requirement, continued pulse system, which keeps sending a DC current even when an AC voltage lowers remarkably, has been used. The stability is much more improved by adding damping control which modulates converter active and/or reactive power. In order to make full use of such control effects, it is important that the HVDC system maintains stable operation during faults and reclosing of the AC system. In particular, it is necessary to prevent a repetitive commutation failure following the unbalanced AC transmission line faults. In this paper, the cause of the repetitive commutation failure is discussed by using the AC-DC power system simulator developed by CRIEPI. Based on the analytical result, a stabilization control scheme with on-line extinction angle ...
The DYMAC Communications System is part of a nuclear safeguards system called DYMAC - short for DYnamic Materials ACcountability - that gathers accountability information at the Los Alamos Scientific Laboratory (LASL) Plutonium Processing Facility. The communications system handles transmissions between data-entry terminals and nondestructive assay (NDA) instruments located in the facility, and a computer located in an adjacent building. System design emphasizes reliability rather than high speed to ensure the integrity of data transmissions. This manual is directed toward the person responsible for maintaining the DYMAC Communication System. It describes the components that make up the communications network, explains how they operate, and gives detailed information about all of the connections. Many of the system components are commercially available; some have been modified at LASL for DYMAC purposes; others were designed and fabricated at ...
This Spanish-language master's thesis presents a study which measured special education teachers' knowledge of AIDS (Acquired Immune Deficiency Syndrome) virus transmission and their attitudes toward children with AIDS in schools. Attitudes were then related to social variables such as sex, teacher's age, and knowing someone with AIDS. A survey of 101 Oswego County, New York, special education teachers found that 52 percent had a moderate knowledge about AIDS transmission, and 48 percent of respondents had a positive perception of children with AIDS. Findings also indicated that teachers had received effective training and information about AIDS; teachers seemed to feel insecure about applying that knowledge to particular situations of possible risk; knowing people with AIDS provoked negative or inadequate perceptions of that population; and age, sex, and teaching experience were not related to teachers' perceptions or AIDS knowledge. Several ...
The purpose of the Isotopes Facilities Deactivation Project (IFDP) is to place former isotopes production facilities at the Oak Ridge National Laboratory in a safe, stable, and environmentally sound condition; suitable for an extended period of minimum surveillance and maintenance (S&M) and as quickly and economical as possible. Implementation and completion of the deactivation project will further reduce the risks to the environment and to public safety and health. Furthermore, completion of the project will result in significant S&M cost savings in future years. The IFDP work plan defines the project schedule, the cost estimate, and the technical approach for the project. A companion document, the IFDP management plan, has been prepared to document the project objectives, define organizational relationships and responsibilities, and outline the management control systems to be employed in the management of the project. The project has adopted the strategy ...
Hybrid models for solving unit commitment problem have been proposed in this paper. To incorporate the changes due to the addition of new constraints automatically, an expert system (ES) has been proposed. The ES combines both schedules of units to be committed based on any classical or traditional algorithms and the knowledge of experienced power system operators. A solution database, i.e. information contained in the previous schedule is used to facilitate the current solution process. The proposed ES receives the input, i.e. the unit commitment solutions from a fuzzy-neural network. The unit commitment solutions from the artificial neural network cannot offer good performance if the load patterns are dissimilar to those of the trained data. Hence, the load demands, i.e. the input to the fuzzy-neural network is considered as fuzzy variables. To take into account the uncertainty in load demands, a fuzzy decision making approach has also been ...
Since October 2001 the development of the facility diagnostics for NIF has been funded by the NIF Director through the National NIF Diagnostic Program (NNDP). The current emphasis of the NNDP is on diagnostics for the early NIF quad scheduled to be available for experiment commissioning in FY03. During the past six months the NNDP has set in place processes for funding diagnostics, developing requirements for diagnostics, design reviews and monthly status reporting. Those processes are described in an interim management plan for diagnostics (''National NIF Diagnostic Program Interim Plan'', NIF-0081315, April 2002) and a draft Program Execution Plan (''Program Execution Plan for the National NlF Diagnostic Program'', NIF-0072083, October 2001) and documents cited therein. Work has been funded at Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Naval Research ...
Background and purpose: A series of phase I/II clinical trials are being initiated in several UK centres to explore the use of dose-escalated schedules for the treatment of non-small cell lung cancer (NSCLC). Among them the IDEAL-CRT trial (ISRCTN12155469) will investigate the introduction of individualised 'isotoxic' treatment schedules based on the relative mean lung normalised total dose (rNTDmean), an estimator related to lung toxicity. Since treatment planning will be performed using different treatment planning systems (TPSs), for the quality assurance of the trial we have carried out work to quantify the influence of dose calculation algorithms based on the determination of rNTDmean and on the choice of individualised prescription doses. Material and methods: Twenty-five patient plans with stage I, II and III NSCLC were calculated, with the same prescription dose, using the Adaptive Convolve (AC) and Collapsed Cone (CC) algorithms of the ...
North Carolina is in the process of siting a LLRW disposal facility as the next host state for the Southwest Compact. After two years of site characterization studies at two technically challenging sites, the LLRW Management Authority (the Authority), will submit a license application for the preferred site. One potential site is in unconsolidated Tertiary and Cretaceous deposits of the inner Coastal Plain, the other in fractured sedimentary rocks of the Triassic Deep River Basin. Involved since 1986, the North Carolina Geological Survey (NCGS) provides technical advice to the Division of radiation Protection, the state regulatory agency authorized to approve or deny a license. With the multi-million dollar project behind schedule, and millions of dollars over budget, in February 1992 the Southeast Compact Commission established three project milestones (1) submit license application by December 31, 1993; (2) approve license by March 15, 1994; (3) open facility by ...
Research highlights: #-># The building occupancy affecting the cooling load prediction is studied. #-># PENN model is adopted in this study for predicting the building cooling load. #-># Statistical approach is adopted to result a less prejudice prediction performance. #-># Results show that occupancy data can significantly improve the prediction. -- Abstract: Building cooling load prediction is one of the key factors in the success of energy-saving measures. Many computational models available in the industry today have been developed from either forward or inverse modeling approaches. However, most of these models require extensive computer resources and involve lengthy computation. This paper discusses the use of data-driven intelligent approaches, a probabilistic entropy-based neural (PENN) model to predict the cooling load of a building. Although it is common knowledge that the presence and activity of building occupants have a significant impact on the required ...
This paper describes an approach to solve air quality problems which frequently occur during iterations of the baseline change process. From a schedule standpoint, it is desirable to perform this evaluation in as short a time as possible while budgetary pressures limit the size of the staff available to do the work. Without a method in place to deal with baseline change proposal requests the environment analysts may not be able to produce the analysis results in the time frame expected. Using a concept called the Rapid Response Air Quality Analysis System (RAAS), the problems of timing and cost become tractable. The system could be adapted to assess other atmospheric pathway impacts, e.g., acoustics or visibility. The air quality analysis system used to perform the EA analysis (EA) for the Salt Repository Project (part of the Civilian Radioactive Waste Management Program), and later to evaluate the consequences of proposed baseline changes, consists of three ...
We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.
The Heard Island Feasibility Test (HIFT) demonstrated that coded acoustic signals could be detected at ranges up to 18,000 km with currently available source technology. This paper describes one component of the HIFT where a large aperture vertical line array was deployed to record the signals transmitted from Heard Island. We have performed four analysis Of the VLA receptions, of the Heard Island signals. All four suggest the presence of higher order modes. The frequency- vertical wavenumber analysis and the modal beamforming indicate that mode 3 has the highest amplitude while the modal fitting suggests that made 5--6 are largest. It is difficult to resolve the differences since the SNR at the VLA, nearly 18,000 km with a transmission loss of around 145 dB, is quite low. Individual arrivals could not be distinguished because of the long integration time necessitated by the low SNR.
Studies on the effects of electromagnetic fields (EMF)on human health have been conducted for more than 20 years. None have categorically established or eliminated any connection between EMF and adverse health effects. Nonetheless, 96% of the risk managers working in the utility sector view EMF as an over-riding concern. Public concern over EMF has erupted into legal, as well as regulatory, actions. To date, some utilities have had lawsuits brought against them by customers who claim they developed cancer as a result of nearby high-voltage transmission lines. What`s more, a small handfull of cities have adopted ordinances that specifically limit where and how utilities handle the placement of their transmission lines.
In this paper, the influence of plasma nitriding at temperature 720 deg. C for 20 h on the surface microstructure and interface microstructure of electroplated chromium coating was investigated. In these conditions, interdiffusion, mixing and reaction phenomena of elements originating from the substrate and coating material are more likely to occur, thus increasing the bonding strength between the coating and carbon steel substrate. The change of the structures from the substrate side to the coating surface, and the effect of the substrate steel on the interface structure were studied by cross-sectional transmission electron microscope observation (XTEM). The nitride layer formed on the surface was analyzed by X-ray diffraction method (XRD). After treatment at above conditions a 6-7 {mu}m thick nitride compound layer was formed in surface region and the same thick carbide compound layer was also formed in the interface region between electroplated chromium coating ...
In this paper, the influence of plasma nitriding at temperature 720 deg. C for 20 h on the surface microstructure and interface microstructure of electroplated chromium coating was investigated. In these conditions, interdiffusion, mixing and reaction phenomena of elements originating from the substrate and coating material are more likely to occur, thus increasing the bonding strength between the coating and carbon steel substrate. The change of the structures from the substrate side to the coating surface, and the effect of the substrate steel on the interface structure were studied by cross-sectional transmission electron microscope observation (XTEM). The nitride layer formed on the surface was analyzed by X-ray diffraction method (XRD). After treatment at above conditions a 6-7 #mu#m thick nitride compound layer was formed in surface region and the same thick carbide compound layer was also formed in the interface region between electroplated chromium coating ...
A study has been made of the passive film remaining over pits on stainless steel using a high resolution transmission electron microscope. Type 305 stainless steel was passivated in a borate buffer solution and pitted in ferric chloride. Passive films formed at 0.2 V relative to a saturated calomel electrode were found to be amorphous. Films formed at higher potentials showed only broad diffraction rings. The passive film was found to cover a remnant lacy structure formed over pits passivated at 0.8 V. The metallic strands of the lace were roughly hemitubular in shape with the curved surface facing the center of the pit.
Microstructure characterization is important for controlling the quality of laser welding. In the present work, a detailed microstructure characterization by transmission electron microscopy was carried out on the laser welding cast Ni-based superalloy K418 turbo disk and alloy steel 42CrMo shaft and an unambiguous identification of phases in the weldment was accomplished. It was found that there are {gamma}-FeCrNiC austenite solid solution dendrites as the matrix, (Nb, Ti) C type MC carbides, fine and dispersed Ni{sub 3} Al {gamma}' phase as well as Laves particles in the interdendritic region of the seam zone. A brief discussion was given for their existence based on both kinetic and thermodynamic principles.
Microstructure characterization is important for controlling the quality of laser welding. In the present work, a detailed microstructure characterization by transmission electron microscopy was carried out on the laser welding cast Ni-based superalloy K418 turbo disk and alloy steel 42CrMo shaft and an unambiguous identification of phases in the weldment was accomplished. It was found that there are #gamma#-FeCrNiC austenite solid solution dendrites as the matrix, (Nb, Ti) C type MC carbides, fine and dispersed Ni_3 Al #gamma#' phase as well as Laves particles in the interdendritic region of the seam zone. A brief discussion was given for their existence based on both kinetic and thermodynamic principles.
20 nm thick permalloy elements, with dimensions of 500 x 500 nm"2 and 1000 x 200 nm"2, have been fabricated on 50 nm thick silicon nitride substrate by milling using a focussed ion beam (FIB) microscope. The dose of ion beam used for the milling was varied in order to achieve the best definition for the milled areas. The FIB milled elements were characterised physically by atomic force microscopy (AFM) and bright field transmission electron microscopy (TEM) and magnetically by Fresnel imaging on a TEM modified for magnetic imaging. The FIB milled elements were found to have a more irregular edge and lower magnetic fields for events such as vortex annihilation when compared to elements of the same dimensions fabricated by conventional electron beam microscopy (EBL).
Direct visualization of rare earths in @a- and @b-SiAlON unit-cells is performed through Z-contrast imaging technique in an aberration-corrected scanning transmission electron microscope. The preferential occupation of Yb and Ce atoms in different interstitial locations of @b-SiAlON lattice is demonstrated, yielding higher solubility for Yb than Ce. The triangular-like host sites in @a-SiAlON unit cell accommodate more Ce atoms than hexagonal sites in @b-SiAlON. We think that our results will be applicable as guidelines for many kinds of rare-earth-doped materials.
We have studied the ion-beam synthesis of GaSb nanocrystals in Si by high-fluence '' hot '' implantation of Sb and Ga ions followed by thermal annealing. The Rutherford backscattering, transmission electron microscopy/transmission electron diffraction, Raman spectroscopy and photoluminescence were used to characterize the implanted layers. It was found that the nanocrystal size increases from 5 to 60 nm in the samples annealed at 900"oC up to 20-90 nm in those annealed at 1100"oC. For the samples annealed at 900"oC a broad band in the region of 0.75-1.05 eV is registered in the photoluminescence spectra. The nature of this photoluminescence band is discussed. (author)
Summary 1. In the Greater Yellowstone Ecosystem, bison Bison bison and elk Cervus canadensis nelsoni act as hosts for Brucella abortus. The presence of B. abortus within wildlife populations is an important conservation issue because of the risk of brucellosis transmission from wildlife to cattle. 2. We investigated conditions facilitating contact between bison (40-60% seroprevalence) and elk on a shared winter range in the Madison headwaters area of Yellowstone National Park. We evaluated the effects of snow pack, season, elk and bison population sizes, and wolf Canis lupus predation risk on the degree of spatial overlap between bison and elk from 1991 to 2006. 3. Sixty-eight per cent of 10 093 independent elk observations occurred within the known bison wintering range, 29% occurred with...
A system model for transmission of computer user's data with a finite number of regular users in a resource-sharing mode in parallel distributed information-processing systems is considered. The mini/microcomputer included in the system model is considered to be receiving the mixed arrival data of the user from a picture-phone terminal with uniformly-distributed data arrivals and a teletypewriter terminal with Erlang-distributed data arrivals. The large-memory performance of the mini/microcomputer is analysed with the mixed input data, constant service-times, synchronous transmission and single server interruption through a first-order Markov process. A simple and general approach to calculate the data arrivals from picture-phone and teletypewriter terminals and their mixed data arrivals is presented. Expressions for memory content probability and average queueing delay are derived. The application of the model is illustrated by ...
Resonant overvoltages in EHV transformers can be initiated by transmission line faults. A series of field tests were performed on the 151 mile long Kammer-Marysville 765 kV line in which a sequence of single line to ground faults were applied to one outside phase at 4 different locations. Fault location criteria and fault initiation procedures are presented. Oscillograms recorded the 3 phase response at both terminals of the line; one is transformer terminated, the other is open-ended. A frequency spectrum analysis of the waveforms is provided showing transient frequencies of sufficient magnitude and duration near the EHV transformer's resonant frequency to stimulate internal winding resonant overvoltages. Digital computer studies are presented and agree with the field tests quite favorably.
Defect cluster formation in 14-MeV neutron irradiated polycrystalline copper has been observed by transmission electron microscopy (TEM) and correlated with the increase in yield stress. The measurements indicate that the radiation hardening component of the yield strength in polycrystals is not directly additive to the unirradiated yield strength. A transitional behavior was observed for radiation hardening at low fluences, which produces an anomalous variation of the defect cluster barrier strength with fluence. The behavior is attributed to the effect of grain boundaries on slip band transmission. An upper limit for the room temperature barrier strength of defect clusters in neutron-irradiated copper was determined to be #alpha#=0.23. (orig.).
Reactive power plays an important role in supporting the real power transfer by maintaining voltage stability and system reliability. It is a critical element for a transmission operator to ensure the reliability of an electric system while minimizing the cost associated with it. The traditional objectives of reactive power dispatch are focused on the technical side of reactive support such as minimization of transmission losses. Reactive power cost compensation to a generator is based on the incurred cost of its reactive power contribution less the cost of its obligation to support the active power delivery. In this paper an efficient Particle Swarm Optimization (PSO) based reactive power optimization approach is presented. The optimal reactive power dispatch problem is a nonlinear optimization problem with several constraints. The objective of the proposed PSO is to minimize the total support cost from generators and reactive compensators. It ...
Although cognitive performance in humans and experimental animals can be improved by administering omega-3 fatty acid docosahexaenoic acid (DHA), the neurochemical mechanisms underlying this effect remain uncertain. In general, nutrients or drugs that modify brain function or behavior do so by affecting synaptic transmission, usually by changing the quantities of particular neurotransmitters present within synaptic clefts or by acting directly on neurotransmitter receptors or signal-transduction molecules. We find that DHA also affects synaptic transmission in mammalian brain. Brain cells of gerbils or rats receiving this fatty acid manifest increased levels of phosphatides and of specific presynaptic or postsynaptic proteins. They also exhibit increased numbers of dendritic spines on post...
The present investigation deals with the synthesis of nanostructured nickel ferrite (NiFe2O4) and their liquid petroleum gas-sensing characteristics. The 15-20nm size nickel ferrite has been synthesized at 700degreeC by a simple molten-salt route using sodium chloride as grain growth inhibitor. These nanoparticles exhibit significantly high response towards liquid petroleum gas (LPG) in comparison with ethanol vapor, hydrogen sulfide, ammonia and hydrogen. The gas response towards various gases at their 200ppm concentrations is investigated at 200-450degreeC. Different characterization techniques have been employed, such as differential thermal analysis, X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM) and high resolution transmission elec...
The measurement of level in the liquid nitrogen vessel has been carried out by the weight conversion method using weigher or by putting directly a stick in the vessel. On a large CE tank, the pressure difference was read by manometer. These methods can not be used when the vessel does not put on the weigher or the pipe for manometer is stopped. We noticed the interaction between radiation ({gamma}-ray) and substance and applied it to determine the liquid nitrogen level. The results proved it the easy method for measurement of the level in the large CE tank. Cesium 137 ({gamma}-ray energy: 662 keV) was used as the radiation source. {gamma}-ray transmission dose was determined by GM survey meter. The liquid nitrogen level could be determined by using the change of the transmission dose with amount of liquid nitrogen. (S.Y.)
In globulitic gray iron (3.6 wt.% C, 2.4 wt.% Si and 0.45 wt.% Mn) the decomposition of austenite into bainite is investigated in real time using a new method based on neutron scattering. During the phase transformation transmission spectra of thermal neutrons are continuously recorded containing specific Bragg edges. Thus, the transformation is followed in-situ time resolved by evaluating the relative (micro)structural fractions of the transforming phases from the heights of the corresponding Bragg edges. The progression of the transformation is described and the results are discussed. The observed late time deviations from the Avrami law are explained by residual stresses of the second kind (homogeneous microstresses), which occur during the transformation because of the different specific volumes of the phases. ((orig.))
In globulitic gray iron (3.6 wt.% C, 2.4 wt.% Si and 0.45 wt.% Mn) the decomposition of austenite into bainite is investigated in real time using a new method based on neutron scattering. During the phase transformation transmission spectra of thermal neutrons are continuously recorded containing specific Bragg edges. Thus, the transformation is followed in-situ time resolved by evaluating the relative (micro)structural fractions of the transforming phases from the heights of the corresponding Bragg edges. The progression of the transformation is described and the results are discussed. The observed late time deviations from the Avrami law are explained by residual stresses of the second kind (homogeneous microstresses), which occur during the transformation because of the different specific volumes of the phases. ((orig.)).
Electric supply industry is facing deregulation all over the world. Under deregulated power supply scenario, power transmission congestion has become more intensified and recurrent, as compared to conventional regulated power system. Congestion may lead to violation of voltage or transmission capacity limits, thus threatens the power system security and reliability. Also the growing congestion may lead to unanticipated divergent electricity pricing. Owing to these facts congestion management has become a crucial issue in the deregulated power system scenario. Fast and precise prediction of nodal congestion prices in real time deregulated/spot power market may enable market participants and system operators to keep pace with the congestion by taking preventive measures like transaction resc...
Considers fundamental problems involved in the precise location of faults on high-voltage transmission lines. The influence of pre-fault load on the distance-to-fault measurement problem is analysed and a new method of accounting for load effects is presented. Two of the algorithms considered are precise, containing no simplifyng assumptions and their overall accuracy is limited only by the accuracy of digital impedance relays at both ends of the protected circuit. A third algorithm presents a new approach to the fault location problem, which requires digital impedance relays at one end only of a transmission line. The procedures described are applicable to any system arrangement and are suitable for a wide range of fault resistance values.
This report presents the results of an investigation into currently used methods for installation of underground high voltage power transmission cable, and offers recommendations for potentially improving these methods. Suggested enhancements cover the emplacement of both high pressure oil filled (HPOPT) pipe type and self contained oil filled (SCOF) cable systems. Cost comparisons of conventionally installed cable systems versus systems using proposed techniques and equipment are developed for a specific site selected for study. The report also documents the test results of laboratory experiments conducted to demonstrate the feasibility of using interference fit pipe couplings in place of welded pipe joints. 10 refs., 31 figs., 15 tabs.
Comparative indices are given for the efficiency of phase control of remote-controlled self-compensating high-voltage transmission lines, including a consideration of the power transfer effect between high-voltage line circuits. A description is given of certain circuit variations for performing the technical means of regulating phase shift, and their characteristics which make it possible to evaluate the effect of the phase regulators on the electrical transmission system are also given. An examination is made of problems concerned with the design of lines, relay protection, computation of transfer processes and dynamic stability as well as the computation of over-voltage when shutting off short circuits during amplified electromagnetic ties between line circuits.
We investigate quantum mechanical electron transport along the long axis of the DNA molecule using an effective tight-binding model. The overall contour plot of transmission, the current-voltage characteristics, and the differential conductance are examined for the variation of backbone onsite energy, the energy-dependent hopping strength, and the contact coupling between the leads and the DNA molecule. It is shown that as backbone asymmetry increases, the merging and collapse of the two mini-bands take place and an extra resonance peak in the transmission appears. In addition, we present the modulation of voltage threshold in the current-voltage curves and a double-peak structure in the differential conductance due to the disappearance of the merged mini-band. Finally, in the Coulomb bloc...
The contribution examines whether the construction of high-voltage transmission lines without formal participation of local authorities is permissible. In this connection the question is also treated to what extent municipal co-determination in transmission line construction represents a precondition for the permissibility of compulsory purchase measures. The individual issues treated are: the formal legal situation and current practice in the construction of electricity pylons; individual legal protection in connection with compulsory purchase; the construction of pylons without a construction licence as an infringement of the municipal right to self-government of local authorities; and the effects on the execution of compulsory purchase procedures of the illegality under Building Law of pylons constructed without approval. (RST).
The object of this program was to design and build a self-contained system for remote monitoring of the atmosphere in mines. The system developed uses the mine pager phone line as the primary communication channel and also has the capability of using 208 Hz in the ELF band for wireless transmission through the earth. The depth for through-the-earth transmission is expected to be about 80 to 90 meters in high conductivity soil and is limited by the noise level in the ELF band-pass filters. The underground components of the TEM System are energized by mine power through a battery charger-storage battery power supply. In the event of mine power failure the battery capacity is more than sufficient for 1 week's operation with interrogations every 4 hours.
The analysis of transmission line faults is essential to the proper performance of the power system. It is required if protective relays are to take the appropriate action and in monitoring the performance of relays, circuit breakers, and other protective and control elements. The detection and classification of transmission line faults is a fundamental component of such fault analysis. Another application of fault analysis is in software packages for automated analysis of digital fault recorder (DFR) files. Recently, such a package, called DFR Assistant, was developed for substation applications. This program can be installed locally in a substation, in which case it is connected directly to the DFR via a high speed parallel link, or it can be installed at a central station, in which case it can be configured to automatically analyze events coming from all DFRs.
The paper reports the results of the studies performed at the Electric Research Center of ENEL (Italian National Electricity Board) in the field of compacting high voltage transmission lines, from the point of view of dielectric and corona noise constraints. The results of switching impulse withstand voltage tests, performed on typical compact line insulation configurations, are given and optimization criteria of such insulation configurations in relation to switching impulse are outlined. The constraints regarding surface withstand voltage in polluted conditions of the above insulations are analyzed and the possibility of reducing their dimensions by using unconventional insulation materials is considered. Finally, evaluations of corona noise in the case of optimization of the line encumbrance from the point of view of dielectric constraints are given.
In the present study, human neonatal fibroblasts were isolated from a two-month-old human male. The purpose of the present investigation was the analysis of the morphology (light and transmission electron microscopy), karyotype and growth characteristics of the human neonatal fibroblast cell culture B-HNF-1. Moreover, STR typing and mitochondrial DNA amplification and sequencing was also performed. Analysis of chromosomes count showed that B-HNF-1 cell culture is diploid and has normal male karyotype 46, XY, which was stable during cultivation. The transmission electron microscopy demonstrated the ultra-structure of the B-HNF-1 cells; they have typical morphological features of proteosynthesis-active cells. Large number of fibroblasts bearing different shapes and surface characteristics ad...
Until recently, the wavelength-division-multiplexed (WDM) transmission system has reached record capacities and distances due to innovations such as FEC (Forward Error Correction), distributed Raman amplification, new transmission fiber and advanced optical format. Optical-communication systems exclusively employed conventional On-Off Keying signals in either Non-Return-To-Zero (NRZ) or Return-To-Zero (RZ) format. Recently a number of advanced modulation formats have attracted attention. Some of these formats carry information through On-Off-Keying but also modulate the optical phase in order to enhance the robustness of signal to chromatic dispersion, optical filtering and non-linearities. Through extensive sets of simulation results, we showed that it is possible to replace a channel wit...
This paper describes the specifications, conceptual design, prototype testing and operating experience of an oil-filled high voltage pulse transmission cable adapted from commercially available air-dielectric RF components. Lawrence Livermore National Laboratory's Advanced Test Accelerator (ATA) requires a method of transmitting 250kV, 70 nanosecond pulses from the power conditioning equipment to the accelerator. The oil-filled cable approach was chosen over alternative concepts because of its high voltage holding capacity, long life and flexibility. The criteria for cable and connector design are discussed. The results of prototype testing and performance of the final design are presented.
This book includes the latest developments and covers pump performance, selection and operations, materials, seals and packings, effective fluid characteristics, filtration, piping systems, economics, valves, instrumentation, automatic controls, power transmission equipment, pump and pipeline heating, and more. An extensive data section contains formulas, charts, symbols, nomographs, and standard specification documents.
The Department of Energy has used its seldom-used statutory authority and filed comments with the Federal Energy Regulatory Commission urging support for Public Service Company of Indiana's request that the FERC allow it to sell up to 450 megawatts of firm power to eligible wholesale purchasers at negotiated or market-based rates in exchange for open transmission access for other generators.
(1) Most ancillary services needed for real-time control of the transmission grid and to meet operating criteria can be competitively supplied and competitively procured. (2) The independent service operator (ISO) must directly control the generators and loads, which supply ancillary services. (3) Comparability of access to ancillary services is achievable through the ISO-based competitive market structure.
BackgroundIn recent years, much attention has been given to the spread of influenza around the world. With the continuing human outbreak of H5N1 beginning in 2003 and the H1N1 pandemic...Full Text Available
This presentation summarizes the present upgrade R&D projects in the TileCal collaboration. One project studies the possibility to divide the drawers into smaller minidrawers to simplify maintenance. There are three different front-end projects. There are also projects dealing with high voltage and low voltage distribution, projects for developing PMT dividers, low voltage electronics, data transmission and off-detector electronics.