Recently, a superconducting cryo-electron microscope in which specimens are cooled to the liquid helium temperature (4.2 K) has been developed. The main components and functional features of this new microscope are reported together with application data on polyethylene, poly (4-methyl-1-pentene), valonia cellulose, rock salt, ice crystallites and ceramic superconductor. The resistance to electron radiation damage, of beam-sensitive specimens including polymers has been increased more than ten times. Thus, the microscope has made it possible to take high resolution images and to analyze the crystal-structure of micro-areas. (orig.).
In virtually all forms of life on earth, proteins in each cell are made according to a genetic blueprint, in the form of DNA. The translation of copies of this genetic blueprint (in the form of messenger RNA) into polypeptides is performed on the ribosome, a highly complex molecular machine composed of RNAs and proteins. To this end, special adaptor molecules called transfer RNAs are lined up by the ribosome in the sequence dictated by the genetic code, such that the amino acids carried by these molecules can be linked into a polypeptide. Several cofactors are involved in these processes, some of which require energy freed up by GTP hydrolysis. Although the ribosome was discovered more than 50 years ago, its structure has only been solved recently by X-ray crystallography. Another technique, cryo-electron microscopy, is starting to contribute toward our understanding of the ribosome's function, by portraying its conformational changes and binding ...
The final product of the radwaste conditioning process must satisfy certain requirments and physico-chemical properties in order to assure its safe long-term behaviour. Of course, the foreseen quality assurance and quality control should be conducted by means of non-destructive techniques. This work presents an over-view of various applicable non-destructive methods of analysis, showing their fields of investigation in testing waste packages, together with some arising practical problems. The most promising methods, such as eddy current testing, ultrasonic testing, #gamma#-scanning, #gamma#-spectroscopy, neutron counting and computerized tomography, are treated more deeply and some applications are presented. Particular attention is devoted to the development of a device based on computerized tomography; its essential components are reported and some design problems are also discussed.
The development of structural barriers for nuclear waste packages involves selection of candidate materials, their screening by mechanical and corrosion testing, rigorous accelerated testing, and evaluation and comparison with other package elements. This document presents results from work conducted on titanium and ferrous alloys.
Requirements for food packaging materials include whether there is any interaction between the food and the package during or after the irradiation, and whether as a result of the irradiation, volatile or leachable substances are released from the pack into the food. The performance of cellulose-based materials and plastic films under irradiation are discussed.
First, the problem of food packaging waste is introduced and one of the solutions, the Tetra Pak, is completely described. The article highlights the political sensitivity concerning the landfilling of packaging waste, as is done with the efforts of the Tetra Pak producer concerning the collection of used Tetra Paks and the results of these efforts. The document also informs us about the different recycling options for Tetra Paks, the qualitative prevention (using cleaner packaging), the quantitative prevention (using less packaging) and the sustainable development (using loner lasting packaging). The proposed four-step plan for a communication strategy is company-specific.
A core preservation package was developed to maintain the reservoir characteristics of core samples and consequently to improve the quality of data obtained through laboratory core analyses. The package is a heat-sealable plastic-aluminum laminate similar to those common in the food-packaging industry. The laminated core preservation package acts as an impermeable barrier to water vapor and gases, and is resistant to chemical alteration and degradation by core fluids. These performance characteristics result in effective core preservation by maintaining the fluid content of the core. Other advantages of the laminated package are that it is fast and simple to use and eliminates the cumbersome dip-coat step used in some core preservation methods.
The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other x-ray examinations, especially computerised tomography. PMID:7134769
The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography.
The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography. (orig.).
...The+Wiley+Encyclopedia+of+Packaging+Technology%2C+3rd+Edition FO21+Food+Packaging Wiley::The Wiley Encyclopedia of Packaging Technology, 3rd Edition WILEY ...US | HELP Home / Chemistry / Food Science & Technology / Food Processing, Production & Manufacture / Food Packaging / The Wiley Encyclopedia of Packaging Technology, 3rd Edition ...Manufacture Sensory Science Food Biotechnology Food Chemistry Food Engineering Related Titles Food Packaging Brewing Yeast and Fermentation by Chris Boulton, David Quain Food ...Editor) Journal of Food Process Engineering Journal of Food Processing and Preservation Packaging Research in Food Product Design and Development by Howard R. ...
A specific application of single photon emission tomography to the relative quantitation of the pituitary region is described together with the results obtained in 19 patients with pituitary adenoma...Full Text Available
Purpose. To describe the characteristics of idiopathic macular holes (MH) on optical coherence tomography (OCT) and correlate OCT with clinical assessment. Design....Full Text Available
138 unselected head tomographies of children by computer are reported and analysed. The major aspect stressed by the authors is the excellent precision of this radiological technique.
Design constraints require that as Earth terminal attempting communications with a FLTSATCOM EHF Package (FEP) located onboard a FLTSATCOM satellite be provided with an accurate FEP package. To be precise, the terminal is provided with a coefficient element set from which the ephemeris of a satellite may be computed. This report describes the operation of a user friendly computer program that produces the above mentioned coefficient set so as to provide reference benchmarks from which the ephemeris related operations of the terminal can be judged.
This bibliography contains citations concerning the migration of food-packaging materials into foods. Plastic, glass, cardboard, metal, and ceramic containers are discussed. Techniques for analyzing packaging contamination are included. (Contains 90 citations fully indexed and including a title list.).
In 15 children (in age 2 weeks - 15 years) the computer tomography beside radiological examination was done because of mediastinal diseases. In all cases the computer tomography was valuable. In 4 cases obtained results have changed diagnostic conclusions. The examples are described showing the usefulness of the computer tomography as supplementary diagnostic method in mediastinal diseases in children.
In a joint study conducted by the University Clinic of Radiology, Graz, and the Medical University Clinic, Innsbruck, the results of computer tomography examinations of the abdomen and pelvis in 23 cases of tumours in children are discussed. In children computer tomography resents special difficulties on account of the very poorly developed fatty layers between the organs and the increased incidence of movement artifacts. The importance of computer tomography for the diagnosis of abdominal and pelvic tumours is discussed.
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere.
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere
...it only highlights the different feedstocks used in the production of fiber-based packaging materials or fossil-fuel ones; what about the energy required to convert ...feedstock, is unacceptable in trying to quantify the overall burden a specific packaging material has on the environment. As an aside, the point ... Consequentially, it is difficult to speculate on how much packaging material a company diverts from the landfill by switching from one material to another ...without specifying what geographical region said packaging material resides in. In addition, there is a lot of interest in diverting PET thermoforms from ...
Spices and packaging materials were exposed to gamma irradiation at a dose of 10 KGy. Luncheon was prepared with irradiated or non-irradiated spices. Prepared luncheon was packaged in irradiated or non-irradiated packaging materials. Packaged luncheon was treated with 2 KGy. Treated and untreated packaged luncheon were kept in a refrigerator (1-4 Centigrade) for 12 months. Microbiological, nutritive and chemical characteristics of luncheon were evaluated after processing and during storage; whereas, sensory quality was evaluated only after irradiation. Gamma irradiation decreased the microorganisms counts of spices, packaging materials and packed luncheon and increased the shelf-life of packaged luncheon products. No major differences in moisture, protein, fat, ph value, total acidity, lipid peroxide and volatile basic nitrogen were observed ...
... Database listings you may be interested in: 3rd Party Reviewed Listings Sustainable Industrial Paper Strap - Natural & White High strength, sustainable, recyclable paper strap SDF Strapping, Inc. High Graphics Litho Lam Corrugated High Graphics Corrugated Packaging (Litho-Lam) Accurate Box Company, Inc. EcoSystem Packaging Solution Starch-based loosefill packing peanut system StarchTech GreenChoice 100 100% recycled, clay-coated paperboard Strathcona Paper, L.P. Greener Package Database! comprehensive sustainability data on packaging materials searchable by converted package or raw material standardizes reporting of sustainability claims many ...
Treatment with gamma and electron radiation is becoming a common process for the sterilization of packages, mostly made of natural or synthetic plastics, used in the aseptic processing of foods and pharmaceuticals. The effect of irradiation on these materials is crucial for packaging engineering to understand the effects of these new treatments. Packaging material may be irradiated either prior to or after filling. The irradiation prior to filling is usually chosen for dairy products, processed food, beverages, pharmaceutical, and medical device industries in the United States, Europe, and Canada. Radiation effects on packaging material properties still need further investigation. This paper summarizes the work done by different groups and discusses recent developments in regulations and testing procedures in the field of packaging technology.
The concept of antimicrobial packaging has received great attention because of its potential to enhance food safety. Several studies have explored its applications and effectiveness to suppress pathogenic microorganisms. However, few studies have analyzed the alterations caused in the engineering properties of food-packaging polymers after the incorporation of antimicrobials. Such information is very important to understand the feasibility of producing antimicrobial packaging films on the industrial scale. This review explores the work done so far to evaluate how the incorporation of antimicrobial substances affects the properties of food-packaging systems. This article also emphasizes diffusion studies on antimicrobial substances through packaging films and the analytical solutions used t...
Abstract:- Significant interest has emerged in the introduction of food packaging materials manufactured from biodegradable polymers that have the potential to reduce the environmental impacts associated with conventional packaging materials. Current technologies in active packaging enable effective antimicrobial (AM) packaging films to be prepared from biodegradable materials that have been modified and/or blended with different compatible materials and/or plasticisers. A wide range of AM films prepared from modified biodegradable materials have the potential to be used for packaging of various food products. This review examines biodegradable polymers derived from polysaccharides and protein-based materials for their potential use in packaging systems designed for the protection of food ...
Assembly of infectious adenovirus particles requires seven functionally redundant elements at the left end of the genome, termed A repeats, that direct packaging of the DNA. Previous studies revealed...Full Text Available
A final step in the influenza virus replication cycle is the assembly of the viral structural proteins and the packaging of the eight segments of viral RNA (vRNA) into a fully infectious virion. The...Full Text Available
This guide describes an acceptable method of complying with the Commission's regulations with regard to the quality assurance requirements for the packaging, shipping, receiving, storage, and handling of items for water-cooled nuclear power plants.
This plan describes the Quality Assurance Program which will be applied to spent fuel handling and packaging tests conducted at the Area 25 E-MAD facility, Nevada Test Site (NTS).
... the provisions of NASA Handbook (NHB) 6000.1, Requirements for Packaging, Handling, and Transportation, and/or MIL-STD-2073-1 and MIL-STD-2073-2, ...
The nucleocapsid protein (NC) of retroviruses plays a major role in genomic RNA packaging, and some evidence has implicated the matrix protein (MA) of certain retroviruses in viral RNA binding. To further...Full Text Available
The RNA packaging process for retroviruses involves a recognition event of the genome-length viral RNA by the viral Gag polyprotein precursor (PrGag), an important step in particle morphogenesis. The...Full Text Available
Recent seizures of nuclear materials, and particularly of fissionable nuclear materials, have resulted in an increased awareness of the need for fieldable instrumentation for the detection and characterization of suspect packages and materials. The ability to perform in-field assessments of materials contained in suspect packages is important for several reasons. First, and most importantly, determination of the type and quantity of material provides information critical to personnel safety. The personnel at potential risk may include both the general population in the area of the package and incident response personnel. Additionally, it would be advantageous to gain information that could result in attribution of the suspect package to a particular facility or pathway as soon as possible after interception. Limited access to a suspect package could also require the use of fieldable ...
Microbial population and moisture content of traditional herbal medicines contaminated with 3 kinds of aerobic microbes, packed in 5 kinds of plastic packaging materials, followed by irradiation at minimum dose of 5 kGy and stored for 6 months were investigated. The highest reduction of microbial counts during storage was observed on samples packed in polyethylene bags. All of packaging materials used were found to be impermeable to microbes and water vapour. Radiation and packaging materials used acted synergistically to inactivate microbes durind storage. The microbial counts decreased as much as 2 to 4 log cycles during storage. (author).
In view of the interest in the use of gamma irradiation to extend the storage life of pre-packaged foods a report is made on the effects of gamma radiation on the migration of Irganox 1076 and Irganox 1010, antioxidants present in food packaging plastics, into synthetic triglyceride fatty-food simulant HB307 and iso-octane. The extent of migration was assayed by h.p.l.c. techniques. Migration into HB307 and iso-octane decreased steadily as irradiation progressed suggesting that gamma irradiation of packaging materials helps to prevent the contamination of food by antioxidants in the packaging. (U.K.).
2.1.1 Levels of preservation and packaging and the levels of packing to be applied selectively are defined in MIL-STD-2073-1 and are mandatory for use or ...
The effects of irradiation on microbiological controlling, nutrient and sensory qualities of packaged tofu (bean curd) stored at commercial condition. Results showed that D10 values of Listeria innocua and Samonella enteritidis inoculated in packaged tofu were 0.225 and 0.240kGy, respectively. Irradiation dose lower than 2.0kGy had no significant effects on content of crude protein and amino acid (p>0.05). ?-irradiation could decrease microbial in packaged tofu and 2.0kGy should be applied to ensure the hygienic quality of the products. (authors)
This study examines the effects of intravenous infusion of adenosine and sublingual nitroglycerin on coronary angiograms obtained by current-generation multidetector computed tomography. We assessed...Full Text Available
Background and objectives: Management of incidental renal artery and kidney abnormalities in patients undergoing computed tomography scans is a clinical challenge because their frequency in healthy...Full Text Available
The purpose of this study was to determine the thickness of the macula and the retinal nerve fiber layer (RNFL) in Japanese subjects by Stratus optical coherence tomography (OCT), and to compare the...Full Text Available
ObjectiveThe aim of this study was to evaluate the utility of volume-rendered helical computerized tomography (CT) angiography focusing tracheostomy tube and innominate artery for...Full Text Available
PurposeTo describe ocular findings for a 34-year-old man with chronic solar retinopathy using high-speed ultrahigh-resolution (UHR) optical coherence tomography (OCT).Full Text Available
Purpose.To investigate the characteristics of a spectral-domain optical coherence tomography (SD-OCT) image phenomenon known as the mirror artifact, calculate its prevalence, analyze...Full Text Available
The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y...Full Text Available
We present a method to make phantoms of coronary arteries for intravascular optical coherence tomography (IV-OCT). The phantoms provide a calibrated OCT response similar to the layered structure of...Full Text Available
The report describes the studies carried out to design a non-destructive system for the radiological characterization of packages containing LLW and MLW. This technique is applied for quantitative and qualitative gamma emitters determination in packages with homogeneous and heterogeneous matrices as well as the development of a maximum activity points location system. Development involves also the automatization for its industrial use.
DescriptionThe objective is to exploit the use of wheat as an industrial raw material and understand the effect of material variation in wheat starch and flour on final material properties for food packaging applications. The project will focus on property enhancement in terms of stiffness, strength, toughness, moisture barrier resistance, transparency, ageing resistance, microbial stability and biodegradability of starch-based packaging materials made by sheet extrusion and thermoforming processes, in ord [continued...
Dosimetric studies in 80 patients examined with the tomographic device 'Somatom' are reported. The gonad doses are compared to those of conventional radiographic techniques.
Ultrasound tomography is an attractive imaging method for the detection of breast cancer. The complex anatomy of the breast with its different spatial scales and material property contrasts make accurate reconstructions very challenging. This paper proposes a hybrid approach whereby Travel-of-Flight and Diffraction Tomography are combined together to achieve high-resolution and high-accuracy sound-speed reconstructions. The method is validated with several numerical phantoms.
Computer tomography used in the diagnosis of tumours is described in the light of particularly great diagnostic difficulties in children. Computer tomography was applied in 12 cases. A high diagnostic value of this method was demonstrated, which makes possible a more accurate diagnosis of the position of the tumour, its size, and expanding tendency. The possibility of estimating healthy tissues and organs, and those with pathological changes on the basis of differences in their density with a detection threshold at 0.5% density difference facilitates not infrequently preoperative diagnosis raising the value of the method.
A method for elucidating complex abnormalities of CSF circulation by using a positive contrast medium (metrizamide) and computer tomography is described. The technique for the method, the results and their clinical significance is demonstrated. The value of this method is compared with traditional ventriculography and with computer tomography without the use of contrast medium. It is shown that the technique represents an important extension of the scope of computer tomography.
Corrosion is a primary determinant of waste package performance at the proposed Yucca Mountain Repository and will control the delay time for radionuclide transport from the waste package. Corrosion is the most probable and most likely degradation process that will determine when packages will be penetrated and the shape, size, and distribution of those penetrations. The general issues in corrosion science, materials science and electrochemistry are well defined, and the knowledge base is substantial for understanding corrosion processes. In this paper, the Yucca Mountain Repository is viewed from a corrosion perspective. A major component of the long-term strategy for safe disposal of nuclear waste at the Yucca Mountain Repository is first to completely isolate the radionuclides in the waste packages for long times and to greatly retard the egress and transport of radionuclides from penetrated ...
This paper discusses the new quality assurance regulations of the Nuclear Regulatory Commission (NRC) for packaging and transportation of radioactive materials. These regulations became effective on October 18, 1977. Background information concerning these regulations and packaging and transportation history is included. The quality assurance program is described with indications of how it is composed of general (administrative) provisions which must meet the 18 quality assurance criteria and be approved by the NRC; specific provisions which appear in the DOT and NRC regulations and in the individual package design approval; and other specific procedures which are not required by regulations but which are necessary for the proper control of quality. The quality assurance program is to be developed using a graded approach for the application of pertinent criteria and optimizing the required degree of safety and control ...
Network tomography aims at inferring internal network characteristics based on measurements at the edge of the network. In loss tomography, in particular, the characteristic of interest is the loss rate of individual links. There is a significant body of work dedicated to this problem using multicast and/or unicast end-to-end probes. Independently, recent advances in network coding have shown that there are several advantages from allowing intermediate nodes to process and combine, in addition to just forward, packets. In this paper, we pose the problem of loss tomography in networks that have network coding capabilities. We design a framework for estimating link loss rates, which leverages network coding capabilities and we show that it improves several aspects of tomography, including the identifiability of links, the tradeoff between estimation accuracy and bandwidth efficiency, and the complexity of ...
This bibliography contains citations concerning toxicity investigations of polymeric materials in food-contact applications. Polymeric food-packaging materials and regulations are discussed. Toxicity testing, polymeric equipment in food processing, and the use of additives in food packaging are included. Discussions also include coating materials for food containers and pigments for food packaging films. (This updated bibliography contains 275 citations, 10 of which are new entries to the previous edition.)
The development of Callossobruchus chinensis (L.) in different packaging materials were conducted with gram and lentil seeds under control temperature. The highest population rise was recorded in laminated jute bags and the weight loss of gram increased with the increase of the number of insects. A doses of 0.1 kGy inhibit all metamorphic stages of the beetle. The use of appropriate packaging materials can reduce the risk of re infestation in the post-irradiated food items. 9 refs., 1 fig., 2 tables (author).
This Packaging Review Guide (PRG) provides guidance for Department of Energy (DOE) review and approval of packagings to transport fissile and Type B quantities of radioactive material. It fulfills, in part, the requirements of DOE Order 460.1B for the Headquarters Certifying Official to establish standards and to provide guidance for the preparation of Safety Analysis Reports for Packagings (SARPs). This PRG is intended for use by the Headquarters Certifying Official and his or her review staff, DOE Secretarial offices, operations/field offices, and applicants for DOE packaging approval. This PRG is generally organized at the section level in a format similar to that recommended in Regulatory Guide 7.9 (RG 7.9). One notable exception is the addition of Section 9 (Quality Assurance), which is not included as a separate chapter in RG 7.9. Within each section, this PRG addresses the technical and ...
In this article, several applications of nanomaterials in food packaging and food safety are reviewed, including: polymer/clay nanocomposites as high barrier packaging materials, silver nanoparticles as potent antimicrobial agents, and nanosensors and nanomaterial-based assays for the detection of food-relevant analytes (gasses, small organic molecules and food-borne pathogens). In addition to covering the technical aspects of these topics, the current commercial status and understanding of health implications of these technologies are also discussed. These applications were chosen because they do not involve direct addition of nanoparticles to consumed foods, and thus are more likely to be marketed to the public in the short term.
This paper reports the development of a relay coordination package specially designed as a teaching aid. Fault studies required for relay coordination has been performed by using a newly developed loop impedance matrix. This new method of forming loop impedance matrix is particularly suitable for multiple fault studies environment as required in relay coordination. A simple topology searching technique has been used to find all loops of the network. This package simultaneously serves the purpose of teaching relay coordination, loop analysis technique and the method of topology searching.
5.2 Network Security. The features listed below can be used to help safeguard UNIX ...... The LaRCSCAN non-intrusive network security scanner package, ...
Oestfold Research has trough the project 'Climate accounts for disposal' for Waste Norway developed a model for calculation of net greenhouse gas emissions at the disposal of various waste types. The model is based on life cycle methodology according to the standard IS014044. This model has been used for plastic packaging in the project by adapting the basic values of specific conditions in the municipality of Fredrikstad. Oestfold Research has made an assessment of greenhouse gas emissions for the recycling and material recovery of plastic packaging from households in the district on assignment from Fredrikstad municipality and compared with the current solution where plastic packaging together with residual waste is used for energy utilisation. Based on the population in Fredrikstad and estimated amount of plastic packaging waste arising per household per year the difference in ...
Eukaryotic genomes are packaged in two basic forms, euchromatin and heterochromatin. We have examined the composition and organization of Drosophila melanogaster heterochromatin in...Full Text Available
An application that provides a flexible and easy to use interface to the GAMMA spectral simulation package is described that is targeted at investigations using in vivo MR spectroscopic methods....Full Text Available
Poly(lactic acid) (PLA) is attractive as a substitute for classical polymer packaging material due to its biodegradability and sufficient mechanical and barrier properties. Presented research was focused on the changes of basic mechanical parameters after ionizing irradiation performed with doses in the range of 2.5-25 kGy, commonly used in radiation sterilization and preservation of foods. Two commercial available PLA packaging films were tested. The influence of radiation dose on the mechanical properties - tensile strength and elongation were determined using standardized methods. Radiation resistance of PLA is sufficient for packaging applications. The investigations of gas products of radiolysis of PLA have been made by gas chromatography after electron beam (EB) irradiations. (authors)
... The thermostable Thermus aquaticus DNA polymerase, (Taq pol), in the presence of excess deoxynucleoside triphosphates (dNTPs), including deoxyadenosine ...
The ultimate compressive strength of 36 thoracolumbar vertebrae was determined experimentally. In addition, the trabecular bone mineral content was measured by single energy quantitative computed tomography. The areas of fractured endplates were also determined by computed tomography. The results show that a linear relationship exists between the compressive strength and the product of bone density and endplate area. These data allow an in vivo prediction of vertebral body strength using a noninvasive method with a standard error of estimate amounting to less than 0.95 kN. PMID:3212488
Computerized tomography of the adrenal glands was performed in 10 patients with Cushing's syndrome using a G.E. 8800 CT/T Body Scanner. The tomographic findings of unilateral adrenal masses in 4 patients were confirmed by surgery. In the remaining 6 patients, computerized tomography did not identify any masses, and both glands were well visualized and showed normal shape. In these patients, measurement of the adrenal glands revealed both normal (n=1) and enlarged glands (n=5). The findings of adrenalectomy (n=4) or transphenoidal surgery and follow-up (n=2) established the diagnosis of adrenal phyperplasia in all patients. (Author).
Absolute measurements of cerebral blood flow (CBF) are an important endpoint in studies of cerebral pathophysiology. Currently no accepted method exists for in vivo longitudinal...Full Text Available
PurposeEarly detection of appendicitis has increased due to development of computed tomography and ultrasonography, yet we are frequently meeting complicated appendicitis, including...Full Text Available
A case of intrathoracic lipoma in a child is presented. The diagnosis was made before operation by means of computer-assisted tomography, a non-interventional procedure.
The authors assess the role of Computed Topography in the diagnosis and management of multiple myeloma (MM) and investigate if Computed Tomography findings can influence the clinical approach, prognosis and treatment. 273 multiple myeloma patients submitted to Computed Tomography June 1994, to December, 1996. The patients were 143 men and 130 women (mean age: 65 years): 143 were stage I, 38 stage II and 92 stage III according to Durie and Salomon's clinical classification. All patients were submitted to blood tests, spinal radiography and Computed Tomography, the latter with serial 5-mm scans on several vertebral bodies. Computed Tomography despicted vertebral arch and process involvement in 3 cases with the vertebral pedicle sign. Moreover, Computed Tomography proved superior to radiography in showing the spread of myelomatous masses into the soft tissues in a case with solitary ...
Current European and the US experiences in waste management are reviewed in the perspective of sustainable development. This publication questions the validity of the current approach taken by the Germany at ``closing the loop`` based on the example of packaging and packaging waste. The product item focus of current German legislation is compared with Danish and US approaches that are based on an integrated policy which covers the whole of waste generation and handling and is not product/item oriented. 1 fig., 2 tabs.
A new commercial cutting tool software package replaced an internally created legacy system. This report describes the issues that surfaced during the migration and installation of the commercial package and the solutions employed. The primary issues discussed are restructuring the data between two drastically different database schemas and the creation of individual component graphics.
The K 2010 exhibition saw the introduction of PolyOne Corps OnCap Antifog Additive for polypropylene (PP) films, the first such additive for PP films that does not require corona treatment. According to the company, this new additive simplifies production of antifog films for the flexible food packaging industry, improving production efficiencies for both cast and blown film producers.
We present a drawing package optimised for Feynman diagrams. These can be constructed interactively with a mouse-driven graphical interface or from a script file, more suitable to work with a diagram generator. It provides most features encountered in Feynman diagrams and allows to modify every part of a diagram after its creation. Special attention has been paid to obtain a high quality printout as easily as possible. This package is written in Tcl/Tk and in C. (orig.).
An update of the ODEtools Maple package, for the analytical solving of 1st and 2nd order ODEs using Lie group symmetry methods, is presented. The set of routines includes an ODE-solver and user-level commands realizing most of the relevant steps of the symmetry scheme. The package also includes commands for testing the returned results, and for classifying 1st and 2nd order ODEs.
APOBEC3G exerts its antiviral activity by targeting to retroviral particles and inducing viral DNA hypermutations in the absence of Vif. However, the mechanism by which APOBEC3G is packaged into virions...Full Text Available
...j-3/j-3311/DLAD/rev5.htm ), and MIL-STD-2073-1, Standard Practice for Military Packaging (and...Guidelines will comply with DLAD 47.305-1, and MIL-STD-2073-1. (f) Delays in delivery caused by...
Installation of the electrical equipment at the Barstow Solar Pilot Plant is the concern of this construction package. Technical specifications for power and instrument cables, meteorological instruments, and control cables are defined. The documentation requirements are briefly discussed.
The University of Groningen (RUG) has developed an expert system on cleaning of biomass producer gas. This work was carried out in close co-operation with the Biomass Technology Group B.V. (BTG) in Enschede, The Netherlands within the framework of the EC supported JOR3-CT95-0084 project. The expert system was developed as a tool for the designer-engineer of downstream gas cleaning equipment and consists of an information package and a flowsheet package. The packages are integrated in a client/server system. The flowsheeting package of the expert system has been designed for the evaluation of different gas cleaning methods. The system contains a number of possible gas cleaning devices such as: cyclone, fabric filter, ceramic filter, venturi scrubber and catalytic cracker. The user can select up to five cleaning steps in an arbitrary order for his specific gas cleaning problem. After specification of the ...
It is reported on examination-technical possibilities with craniocerebral Computer Tomography in the peri- and postnatal period. Some typical tomographic images from a 17 1/2 months period in our own patient material of 327 children are demonstrated. The special advantages of this new technical-extensive method are: exact diagnoses, observation possibility of the longitudinal section, and the absolute harmlessness to the child.
The article explains the method of selecting the optimum energy for correcting the energy selectivity of tomographic projection and the optimum length of the crystals corresponding to it when the dual energy method in computerized tomography is used. Results of numerical calculations for actual materials and count results are presented.
We retrospectively studied the computed tomography scans of the orbit in 75 patients in order to identify the presence of incidental calcifications (scleral and trochlear apparatus calcifications.). These imaging findings should integrate the vast list of differential diagnosis of orbital calcifications, as they may help radiologists to distinguish these calcifications from orbital foreign bodies. (author)
In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).
Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computer tomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained
The radiologic appearance of inflammatory and tumorous lesions in the iliac bone is characterized by destructive alterations and consolidations simultaneously. This pattern is nonspecific. The value of plain films of this area is compromised by the anatomy of the iliac bone and by overlying structures. Therefore tomography, computer tomography and bone scans are necessary. Difficulties in differentiation between benign and malignant lesions are discussed and case reports are given. The importance of histologic examination is stressed.
In this study the development of a methodology to detect illicit drugs and plastic explosives is described with the objective of being applied in the realm of public security. For this end, non-destructive assay with neutrons was used and the technique applied was the real time neutron radiography together with computerized tomography. The system is endowed with automatic responses based upon the application of an artificial intelligence technique. In previous tests using real samples, the system proved capable of identifying 97% of the inspected materials.
The experiences are described of the examination of orbita in children using computer tomography (CT). Over a period of four years 42 examinations were performed of children in the age ranging between 7 months and 15 years, i.e., 2.7 percent of all CT examinations performed. The highest diagnostic yield was in orbita tumours. The possibilities of CT are demonstrated on examples.
Computed tomographic findings in developmental brain anomalies are more easily classified when the system used is based on embryogenesis related to morphology. Analysis of computed tomographic findings in a series of 154 patients with brain anomalies (Chiari malformation not included) revealed that specific examples of abnormalities occurring in major stages of brain development may be recognized by computed tomography. This paper deals with a group of patients with abnormalities that reflect a disturbance in neuronal migration. (orig.).
Several recently introduced 'new' techniques in computed tomography - iterative reconstruction, gated cardiac CT, multiple-source, and dual-energy CT - actually date back to the early days of CT. We review the historic origins and evolution of these techniques, which may provide some insight into the latest innovations in commercial CT systems. (orig.)
Compton scatter tomography utilizes the electronic collimation characteristics available through the Compton scattering angle-energy correlation to obtain tomographic images. In this work we present particular aspects of the technique, which are relevant to the inverse radiation transport problem of reducing marginal projection data to radial two-phase flow regime maps. The results indicate a viable technique for the tomographic imaging of tow-phase flow using practical source strengths and reasonably few detectors.
In the case where sources and receivers are not distributed on a 2-D plane, seismic tomography inversion was studied. In tomography experiments, the existing wells are generally used. In such case, sources and receivers are frequently not distributed on a 2-D plane. The 2.5-D analysis method including 2-D structure and 3-D ray-tracing was thus developed. This method is featured by less memory necessary for ray-tracing calculation, and the same algorithm for velocity determination as 2-D analysis method. In previous methods, since analysis is generally carried out by projecting sources and receivers on a certain assumed 2-D plane, it can derive correct results in the case of constant velocity and straight ray, however, in the other case, it derives incorrect results. Application of 3-D tomography requires a large amount of memory, and falls into poor convergence because of various parameters. The 2.5-D analysis method can ...
The main aim of any food irradiation treatment is to guarantee the best safe quality of the products, reducing the spreading risk ("cross-contamination") for several food-associated diseases. Actually, over 40 countries provide clearances for the treatment of about 45 different types of foodstuffs. EU has to homogenise the situation within the associated States. With the European directive 1999/2/EC Italy, as other EU countries, already has brought into force their regulations to comply. The current Italian regulation on irradiation treatment of foodstuffs is referred since 1996 as follows: a) potatoes, onions and garlic; b) spices, herbs and condiments microbial. The new (April 2001) Italian law allows the possibility to ask for special permission of treatment for other foodstuff which is possible to treat in other E.U. countries. Large majority of foods are submitted to irradiation treatment after they have been packaged. In Dutch cases the study of radiation ...
1 - Description of program or function: The COOLOD-N2 code provides a capability for the analyses of the steady-state thermal-hydraulics of research reactors. This code is a revised version of the COOLOD-N code, and is applicable not only for research reactors in which plate-type fuel is adopted, but also for research reactors in which rod-type fuel is adopted. In the code, subroutines to calculate temperature distribution in rod-type fuel have been newly added to the COOLOD-N code. The COOLOD-N2 code can calculate fuel temperatures under both forced convection cooling mode and natural convection cooling mode. A 'Heat Transfer package' is used for calculating heat transfer coefficient, DNB heat flux etc. The 'Heat Transfer package' is a subroutine program and is especially developed for research reactors in which plate-type fuel is adopted. In case of rod-type fuel, DNB heat flux is calculated by both the 'Heat Transfer ...
The authors compared unenhanced and contrast-enhanced fast MRI and Computerized Tomography in the detection of liver metastases. Eleven patients with single or multiple hepatic lesions (42 in all) were submitted to V and magnetic resonance studies; T1- and T2- weighted TSE, T2-weighted TSE with fat suppression, unenhanced breath-hold TFE and early or delayed enhanced breath-hold TFE images were acquired with a 1.5 T superconductive magnet (Philips NT). The quantitative analysis of all magnetic resonance images was performed for contrast/noise ratio (CNR) and number of detected lesions; magnetic resonance and Computerized Tomography images were also compared qualitatively for lesion conspicuity, anatomical structure identification and artifacts. The results were compared with Student's test. Early enhanced breath-hold TFE was statistically superior to T1-weighted TSE (p = .0009), T2-weighted TSE (p = .01) and Computerized ...
TOXCHEM is a microcomputer based modelling system for predicting the fate of toxic contaminants in wastewater treatment plants. The package evaluates concentrations of toxics in final effluent and waste sludge, and mass air emissions from municipal or industrial activated sludge wastewater treatment plants. Maximum allowable influent concentrations of toxics required to meet effluent discharge or air emission limits can also be estimated. The package contains a read-only database with treatability parameters for over 100 contaminants, including organic compounds and metals. If effluent or sludge quality limits have been specified, treatment plant owners and operators can use the package to estimate the permissable discharge limits for dischargers to their collection system. A hypothetical example is provided of application of the software to a planning problem involving the start up of a new operation that would discharge ...
This report documents the findings of the peer panel constituted by Argonne National Laboratory to review Region A of Westinghouse Electric Corporation's report entitled Waste Package Reference Conceptual Designs for a Repository in Salt. The panel determined that the reviewed report does not provide reasonable assurance that US Nuclear Regulatory Commission (NRC) requirements for waste packages will be met by the proposed design. It also found that it is premature to call the design a ''reference design,'' or even a ''reference conceptual design.'' This review report provides guidance for the preparation of a more acceptable design document.
Joint FAO/IAEA/WHO Expert Committee approved the use of radiation treatment of foods. Nowadays food packaging are mostly made of plastics, natural or synthetic, therefore effect of irradiation on these materials is crucial for packing engineering for food irradiation technology. By selecting the right polymer materials for food packaging it can be ensured that the critical elements of material and product performance are not compromised. When packaging materials are in contact with food at the time of irradiation that regulatory approvals sometimes apply. The review of the R-and-D and technical papers regarding material selection, testing and approval is presented in the report. The most information come from the USA where this subject is well elaborated, the International Atomic Energy Agency (IAEA) reports are reviewed as well. The report can be useful for scientists and food irradiation plants operators. (author)
This study was focused on the possibility to inactivate main food pathogens, their spores and biofilms on the surface of packaging material polyolefine by Na-chlorophyllin (Na-Chl)-based photosensitization and to compare efficiency of this treatment with conventional antimicrobials. Data indicate that Bacillus cereus and Listeria monocytogenes were effectively inactivated (7 log) by Na-Chl (7.5x10-7M)-based photosensitization in vitro and on the surface of packaging. Meanwhile to achieve adequate inactivation of thermo-resistant strains, spores or biofilms the higher Na-Chl concentration and longer illumination times had to be used. Comparison of different surface decontamination treatments reveal that photosensitization is much more effective against B. cereus and L. monocytogenes attache...
The effect on human health of using food packaging made from recycled materials will depend on whether the elements will migrate into the food itself and at which levels that would be of concern. There is no EU directive for paper and board packaging, but guidelines on paper and board intended to come into contact with food are being developed in another forum. These do not propose limits for paper intended to come into contact with dry foods. However, for other foodstuffs, restriction limits in paper of 0.002 mg/dm"2 (Cd), 0.003 mg/dm"2 (Pb), and 0.002 mg/dm"2 (Hg) have been proposed. This paper describes a radiotracer method that has been applied to the determination of migration of trace elements from paper and board into real food samples.
This study was focused on the possibility to inactivate thermosensitive Listeria monocytogenes ATCL3C 7644 and thermoresistant 56 Ly strain by Na-Chlorophyllin (Na-Chl)-based photosensitization in vitro and on the surface of packaging. Comparative analysis of antimicrobial efficiency of photosensitization with conventional surface cleaning was performed. Data indicate that both Listeria strains, after incubation with Na-Chl and following illumination (l=400nm, 20mWcm-2), were inactivated by 7 log in vitro. This treatment cleaned both Listeria strains from packaging surfaces. Comparative analysis indicates that washing with water diminishes pathogens by less than 1 log, 200ppm Na-hypochlorite by 1.7 log, Na-Chl-based photosensitization by 4.5 log. Listeria biofilms were totally removed from...
The need for safe food products has motivated food scientists and industry to find novel technologies for antimicrobial delivery for improving food safety and quality. Controlled release packaging is a novel technology that uses the package to deliver antimicrobials in a controlled manner and sustain antimicrobial stress on the targeted microorganism over the required shelf life. This work studied the effect of controlled release of nisin to inhibit growth of Micrococcus luteus (a model microorganism) using a computerized syringe pump system to mimic the release of nisin from packaging films which was characterized by an initially fast rate and a slower rate as time progressed. The results show that controlled release of nisin was strikingly more effective than instantly added (?formulated...
Irradiation processing of food in the prepackaged form may affect chemical and physical properties of the plastic packaging materials. The effect of #gamma#-irradiation doses (2.5-10.0 kGy) on polypropylene (PP)-based retortable food packaging materials, were investigated using Fourier transform infrared (FTIR) spectroscopic analysis, which revealed the changes happening to these materials after irradiation. The mechanical properties decreased with irradiation while oxygen transmission rate (OTR) was not affected significantly. Colour measurement indicated that Nylon 6 containing multilayer films became yellowish after irradiation. Thermal characterization revealed the changes in percentage crystallinity.
A mathematical model was developed to predict a moisture content profile during the thick layer re-wetting process of brown rice unpackaged and packaged with low density polyethylene (LDPE) and polybutylene terephthalate (PBT) films. Model validation was carried out by comparing predicted with measured moisture content derived from relative humidity data obtained from the brown rice re-wetting test for 6days at 25degreeC and 90% RH. The moisture standard errors of the model validation for brown rice packaged in LDPE and PBT films were 0.08% wet basis (wb) and 0.11%wb, respectively. It was concluded that the proposed re-wetting model could successfully describe the thick layer re-wetting of brown rice under the experimental conditions. Using this model, re-wetting simulations were carried o...
The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...
The authors have evaluated bone mineral content in the vertebral spongiosa by means of Computed Tomography. The method proposed by Genant and Cann [17, 18] has been applied to examine 164 healthy volunteers and 108 patients. Both healthy males and females showed a progressive bone mineral loss increasing with age; the bone mineral loss was most severe in females during the 4th and 5th decade of life. Pathology included patients with osteoporotic fractures (vertebral and femural neck), patients with partial gastrectomy, renal failure, primary hyperparathyroidism, Cushing syndrome, corticosteroid therapy. Bone mineral values were significantly lower in most pathologic groups. Computed Tomography proves thus to be a valuable method to assess bone mineral content and to identify patients at risk for fractures.
Tree-level scattering amplitudes of longitudinally polarized electroweak vector bosons in the Standard Model are calculated using Mathematica package Feyncalc. The modifications of low-energy theorems for longitudinally polarized W and Z in the Standard Model are discussed.
Gas turbine component protection remains essential but environmental regulations emphasize the gas-turbine efficiency. Heating and cooling are features often integrated into the GI air intake packages to provide the optimum operating conditions. This paper describes modern inlet air treatment systems and discusses their effectiveness. (author)
AbstractThe Galaxy package empowers regular users to perform rich DNA sequence analysis through a much-needed and user-friendly graphical web interface.See research article...Full Text Available
Overview Package  Class Use Tree Deprecated Index Help  PREV CLASS  NEXT CLASS FRAMES   NO FRAMES SUMMARY:  INNER | FIELD | CONSTR | METHOD DETAIL:  FIELD | CONSTR | METHOD gov.nih.nci.dc.database Class SearchCriteria java.lang.Object |
An overview of the operations of Sandia`s Microelectronics Development Lab (MDL) is to develop radiation hardened IC, but techniques used for IC processing have been applied to a variety of related technologies such as micromechanics, smart sensors, and packaging.
Sewage waste disposal facilities in the Florida Keys include septic tanks and individual package plants in place of municipal collection facilities in most locations. In Key Largo, both facilities discharge...Full Text Available
The genomic viral RNA (vRNA) segments of influenza A virus contain specific packaging signals at their termini that overlap the coding regions. To further characterize cis-acting signals...Full Text Available
Study of cloud pictures taken from rockets, such as figure 1, indicates that it is .... One might visualize a "Satellite Weather Data Center" where incoming data would ... about 300 miles; satellite packaging, containing the sensors, storage, power, ...
An interactive system for computer analysis of nucleic acid and protein sequences has been developed for the Los Alamos DNA Sequence Database. It provides a convenient way to search or verify various...Full Text Available
The human immunodeficiency virus type 1 (HIV-1) packages its genomic RNA as a dimer of homologous RNA molecules that has to be selected among a multitude of cellular and viral RNAs. Interestingly, spliced...Full Text Available
A Staphylococcus strain was inoculated on the top and cut surfaces of freshly baked Southern custard pies which were then packaged in a pasteboard carton and held at 30 C. Daily plate...Full Text Available
It was thus actually the fourth stage of the rocket assembly. ... package, and several temperature sensors - was mounted in the cross-lattice frame. ... Earth's geomagnetic field and incoming charged particles from the Sun and extra-solar space. ...
BackgroundMicroarray data are often used for patient classification and gene selection. An appropriate tool for end users and biomedical researchers should combine user friendliness...Full Text Available
Vegetable oils such as soybean oil will be converted to novel polymers using hydroformylation and other catalytic processes. These polymers can be used in the construction, automotive, packaging, and electronic sectors.
An experimental investigation of natural convection heat transfer from a commercially available semiconductor device package is presented. The package was centrally mounted on a ceramic substrate. The package-substrate assembly formed one surface of a dielectric-filled cubical enclosure of aspect ratio one. The top surface of the enclosure was maintained at prescribed temperature. Surface temperature measurements were made at various locations on the substrate, the package lid, as well as the chip center. These measurements are reported for three dielectric fluids and three enclosures top surface temperatures, both with the substrate oriented horizontally as well as vertically. The results indicate that the maximum input power without exceeding a chip junction temperature of 80 C is 2.58 watts with FC-75 as the cooling fluid and the upper boundary maintained at 15 C. This is significantly larger than ...
This article reports of the nickel-metal-hydride battery and its ability to compete with the lead-acid battery in electric-powered vehicles. The topics of the article include development of the battery, the impetus for development in California environmental law, battery performance, packaging for the battery's hazardous materials, and the solid electrolyte battery.
Different concrete waste packages have been designed by Electricite de France (EDF) for the long-term storage of radioactive Low Level Waste (LLW). Their main function is to confine radionuclides from the biosphere for three hundred years in a near-surface disposal. According to the transport regulations, a Type-B package is needed for some waste like water filters. The water filters from EDF nuclear power plants are encapsulated in mortar and placed in a concrete container. Transport regulations for these containers have required the development of a methodology for safety assessment. The reference scenario of container degradation during transport considers a 9 m drop and a 800"oC fire for 30 min. First, the different chemical and physical processes involved in the containment of radionuclides are analysed. In particular, the radionuclide transport mechanisms in cement-based materials have been reviewed. Secondly, the effects of a container ...
In a cross-over study, participants (n=59) were randomly assigned to receive either 100 kcal packs or standard size packages of snacks for 1-week. After a minimum of a 1-week washout period,...Full Text Available
A second-generation solar disinfection (SODIS) system (pouch) was constructed from food-grade, commercially available packaging materials selected to fully transmit and amplify the antimicrobial properties...Full Text Available
Generation of replicative defective viruses is frequently observed during viral infections. We now report that encapsidation and reverse transcription of spliced viral RNA is an additional mechanism...Full Text Available
This report describes mathematical predictions for the migration of radionuclides from an emplaced radioactive waste container. The model assumes a spherical-equivalent waste solid surrounded by backfill but neglects the effect of decay heat. 7 refs., 2 tabs. (TEM)
During the course of a fiscal year, Oak Ridge National Laboratory`s Carbon Dioxide Information Analysis Center (CDIAC) distributes thousands of specialty publications-numeric data packages (NDPs), computer model packages (CMPs), technical reports, public communication publications, newsletters, article reprints, and reference books-in response to requests for information related to global environmental issues, primarily those pertaining to climate change. CDIACs staff also provides technical responses to specific inquiries related to carbon dioxide (CO{sub 2}), other trace gases, and climate. Hundreds of referrals to other researchers, policy analysts, information specialists, or organizations are also facilitated by CDIAC`s staff. This report provides an account of the activities accomplished by CDIAC during the period October 1, 1991 to September 30, 1992. An organizational overview of CDIAC and its staff is supplemented by a detailed ...
The genomic termini of RNA viruses contain essential cis-acting signals for such diverse functions as packaging, genome translation, mRNA transcription, and RNA replication, and thus...Full Text Available
The Savannah River Site (SRS) is currently developing a new facility, the Actinide Packaging and Storage Facility (APSF), to process and store legacy materials from the United States nuclear stockpile. A variety of materials, with a variety of properties, packaging and handling/storage requirements, will be processed and stored at the facility. Since these materials are hazardous and radioactive, automation will be used to minimize worker exposure. Other benefits derived from automation of the facility include increased throughput capacity and enhanced security. The diversity of materials and packaging geometries to be handled poses challenges to the automation of facility processes. In addition, the nature of the materials to be processed underscores the need for safety, reliability and serviceability. The application of automation in this facility must, therefore, be accomplished in a rational and disciplined manner to ...
The state of chromatin (the packaging of DNA in eukaryotes) has long been recognized to have major effects on levels of gene expression, and numerous chromatin-altering strategies—including...Full Text Available
Packages used for the storage and transportation of radioactive spent fuel must demonstrate the ability to withstand severe impact scenarios such as those established by the Atomic Energy Control Board (AECB) in Canada and the International Atomic Energy Agency (IAEA). One such package is the Dry Storage Container (DSC) for transporting and storing used fuel. The DSC model is comprised of several interactive components with materials such as high density concrete and polyurethane foam. To accurately model these materials, experimental studies were performed in order to provide material properties for the in-house finite element analysis code used. Structural assessments of the package design subject to postulated impact scenarios included a 9 meter center of gravity over corner drop, a 1 meter pin drop over the welded lid closure and a 1 meter center of gravity over lid pin drop. Simulations were carried out using full ...
The primary method for neuronal communication involves the extracellular release of small molecules that are packaged in secretory vesicles. We have developed a platform to separate, lyse, and...Full Text Available
On July 18, 2001, a freight train carrying hazardous (non-nuclear) materials derailed and caught fire while passing through the Howard Street railroad tunnel in downtown Baltimore, Maryland. The United States Nuclear Regulatory Commission (USNRC), one of the agencies responsible for ensuring the safe transportation of radioactive materials in the United States, undertook an investigation of the train derailment and fire to determine the possible regulatory implications of this particular event for the transportation of spent nuclear fuel by railroad. Shortly after the accident occurred, the USNRC met with the National Transportation Safety Board (NTSB, the U.S. agency responsible for determining the cause of transportation accidents), to discuss the details of the accident and the ensuing fire. Following these discussions, the USNRC assembled a team of experts from the National Institute of Standards and Technology (NIST), the Center for Nuclear Waste Regulatory Analyses (CNWRA), and ...
Guidelines and ground rules followed in the development of requirements for the SPS are presented. Development planning objectives are specified in each of these areas, and evolutionary SPS program scenarios are described for the various concepts studied during the past one year contract. Program descriptions are presented as planning packages of technical tasks, and schedule phasing. Each package identifies the ground based technology effort that will facilitate SPS definitions, designs, development, and operations.
Thermal desorption spectroscopy (TDS) was used to study outgassing from polycrystalline SiGe (poly-SiGe), SiC and SiO"2 films used for poly-SiGe-based MEMS thin film vacuum package technology. Primary desorption products were found to be H"2, H"2O and CO"2. The CO"2 outgassing could be correlated with CF"4 plasma interface cleaning used for thick SiGe PECVD, which can leave carbon at the CF"4-plasma-cleaned interface.
With major D&D projects ongoing or being planned, and also with the daily management of radwaste from nuclear facilities, the potential role of transport packagings has often been overlooked: here will one rely essentially on drums, there several local waste processing units are built, elsewhere decommissioned facilities are cut in small bits to fit into small containers by far less efficient. The present paper proposes to illustrate how integrating a transport system from the start may influence operational choices of waste management.
This report summarizes evaluations by the National Institute of Standards and Technology (NIST) of Department of Energy (DOE) activities on waste packages designed for containment of radioactive high-level nuclear waste (HLW) for the six month period February 1988 through July 1988. Activities for the DOE Materials Characterization Center are reviewed for the period January 1988 through June 1988. A summary is given of the Yucca Mountain, Nevada disposal site activities. Short discussions relating to the reviewed publications are given and complete reviews and evaluations are included. 20 refs., 1 fig., 1 tab.
Electrochemical cyclic potentiodynamic polarization experiments were performed on several candidate waste package container materials to evaluate their susceptibility to pitting corrosion at 90 degrees C in aqueous environments relevant to the potential underground high-level nuclear waste repository. Results indicate that of all the materials tested, Alloy C-22 and Ti Grade-12 exhibited the maximum corrosion resistance, showing no pitting or observable corrosion in any environment tested. Efforts were also made to study the effect of chloride ion concentration and pH on the measured corrosion potential (Ecorr), critical pitting and protection potential values.
The purpose of the present research is to find a suitable technique to measure trace amounts of uranium and thorium and to determine the surface #alpha#-flux in silicon compound (SiO) used for fabrication of integrated circuit packaging materials. Among several commonly-used detecting techniques, it was found that neutron activation analysis (NAA) was most promising. The results from NAA show a large difference in uranium and thorium concentrations when cadmium and boron carbide shields are used, whereas #alpha#-flux measurements show a low #alpha#-activity, which corresponds to the trace amounts of uranium and thorium expected to be present in these materials. (author) 13 refs.; 6 figs.
The objective of this study was to determine the prevalence of concha bullosa and nasal septal deviation and their potential relationships to maxillary sinusitis. 883 CT scans taken at Creighton University...Full Text Available
Advances in laboratory animal imaging have provided new resources for noninvasive biomedical research. Among these technologies is microcomputed tomography (microCT) which is widely used to obtain high...Full Text Available
With regard to the elastic wave exploration, discussions have been given on the relationship between frequency and resolution in P-wave velocity tomography using the initial travel time. The discussions were carried out by using a new analysis method which incorporates the concept of Fresnel volume into tomography analysis. The following two arrangements were used in the calculation: a cross hole arrangement, in which seismic source and vibration receiving points were arranged so as to surround the three directions of a region extending 250 m in the horizontal direction and 500 m in the vertical direction, and observation is performed between two wells, and a permeation VSP arrangement in which the seismic source is installed on the ground surface and receiving points installed in wells. Restructuring was performed on the velocity structure by using a total of 819 observation travel times. This method has derived results of the restructuring ...
BackgroundThe precision in carbon ion radiotherapy depends on the calibration of Hounsfield units (HU) as measured with computed tomography (CT) to water equivalence. This calibration...Full Text Available
ObjectiveTo refine the CT prediction of emphysema by comparing histology and CT for specific regions of lung. To incorporate both regional lung density measured by CT and cluster...Full Text Available
Scatter correction is crucial to the quality of reconstructed images in x-ray cone-beam computed tomography (CBCT). Most of existing scatter correction methods assume smooth scatter distributions. The...Full Text Available
BackgroundIn primary hyperparathyroidism (PHPT) the predictive value of technetium 99m sestamibi single emission computed tomography (Tc99m-MIBI-SPECT) for localizing pathological...Full Text Available
To determine the diagnostic accuracy of iofetamine hydrochloride I 123 (IMP) with single photon emission computed tomography in Alzheimer's disease, we studied 58 patients with AD and 15 age-matched healthy control subjects. We used a qualitative method to assess regional IMP uptake in the entire brain and to rate image data sets as normal or abnormal without knowledge of subjects'clinical classification. The sensitivity and specificity of IMP with single photon emission computed tomography in AD were 88% and 87%, respectively. In 15 patients with mild cognitive deficits (Blessed Dementia Scale score, less than or equal to 10), sensitivity was 80%. With the use of a semiquantitative measure of regional cortical IMP uptake, the parietal lobes were the most functionally impaired in AD and the most strongly associated with the patients' Blessed Dementia Scale scores. These results indicated that IMP with single photon ...
BackgroundNew technology allows more precise definition of structural alterations of all retinal layers although it has not been used previously in cases of optic...Full Text Available
The purpose of this work is to develop a novel feature-based registration strategy to automatically map the rectal contours from planning computed tomography (CT) (pCT) to cone beam CT (CBCT). The rectal...Full Text Available
RATIONALE AND OBJECTIVESNon-invasive longitudinal imaging of tumor vasculature could provide new insights into the development of solid tumors, facilitating efficient...Full Text Available
AIM: To improve the diagnosis of heterotopic pancreas by the use of contrast-enhanced computed tomography (CT) imaging and CT virtual endoscopy (CTVE).METHODS: A total of six patients with heterotopic...Full Text Available
PurposeTo determine the effects of age on global and sectoral peripapillary retinal nerve fiber layer (RNFL), macular thicknesses and optic nerve head (ONH) parameters...Full Text Available
Due to the widespread clinical use of imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available
The diagnostic accuracy of computed tomography (CT) in several patterns of thoracic and abdominal fatty masses, has been examined. In selected cases our findings overlap the features of the recent literature. The possibility of surgical therapy in peculiar cases of adipose deposits, commonly esteemed benign, is considered.
PurposeTo establish normative values for macular light sensitivity and to determine the intrasession fluctuation of perimetric responses using the OPKO/OTI microperimeter.Full Text Available
The comprehensive survey explains the indications and the specific value of the modern tomographic modalities with respect to the various diagnostic issues. Numerous reproductions of CT, MRI, US scans illustrate the aspects discussed. (orig./CB)
We report an unusual patient with primary adenocarcinoma of lung causing malignant pleural and pericardial effusions. The diagnosis was made only at autopsy as his staging computed tomography scan of...Full Text Available
BackgroundIn vitro data suggest that changes in myocardial substrate metabolism may contribute to impaired myocardial function in diabetic cardiomyopathy (DCM)....Full Text Available
Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available
The paper investigates computerized tomography capabilities in showing vascular complications secondary to intestinal obstruction and for assessing the site and cause of obstruction. [Italian] Scopo del lavoro e' lo studio dell'uso della tomografia computerizzata nel riconoscimento di complicanze vascolari secondarie ad occlusione intestinale e della presenza, della natura e della sede dell'ostacolo alla canalizzazione intestinale.
Computed tomography allows today to reconstruct three-dimensional (eD) images fram axial scans. The authors report their experience in cranio-facial pathology achived in two Departments of Radiology (University of Trieste, Italy and University of Standford, California). 3D images have been realized using two different softwares, one of which allows to reconstruct both soft tissue and bone structures. The application in maxillo-facial traumas, cranio-facial malformations and head tumours are disscussed. 3D images turned out to be very useful for the optimal visualization and for the spatial demostration of the lesion and have potential applications in cranio-facial surgery and radiotherapy.
Snapping or grating scapula is a condition of the shoulder girdle in which the patient complains of pain and an audible snapping sound which may be associated with pain. We evaluated the diagnostic value of the computed tomography (CT) scans using the clinical diagnosis of a grating scapula as the gold standard. This retrospective study reports the sensitivity, specificity, likelihood ratio and receiver operator characteristic curve for the CT scans and the k value as a measure of the interobserver agreement. None of the parameters validated the examination. We therefore concluded that CT scans are inappropriate for differentiation between a grating scapula and a normally functioning shoulder except in cases where bony abnormalities are present. (orig.)
Twenty-seven patients with symptoms or clinical findings suggesting joint or bone disorders of the anterior chest wall (ACW) were evaluated by spiral CT with 3-dimensional (3-D) and multiplanar reconstructions. Preceding conventional ACW tomography was performed in 10 patients. ACW joint and bone changes were visualized more adequately by coronal 2-D reconstructions based on spiral CT than by conventional tomography. In addition, nonossified costal cartilages and soft tissue lesions were demonstrated. 3-D reconstructions sometimes added information, especially in patients with fracture and dislocation. (orig.).
Positron-emission tomography (PET) and PET/CT (computed tomography) are becoming increasingly important for diagnosis and treatment of cancer. Clinically relevant changes can sometimes be seen on PET that are not seen on other imaging modalities. However, PET is not suitable for guiding biopsy as the images are not obtained in real-time. Therefore, our research group has begun developing a concept for PET/CT-guided interventional procedures. This paper presents the rationale for this concept, outlines our research plan, and includes an initial study to evaluate the relative sensitivity of CT and PET/CT in detecting suspicious lesions. (orig.)
Positron emission tomography (PET) and X-ray computed tomography (CT) performed with PET/CT cameras allow us to obtain concurrently information on the presence and degree of alterations of myocardial perfusion and metabolism and on coronary arteries calcification. Furthermore, by gated myocardial perfusion studies, PET may provide crucial information on regional coronary blood flow reserve and endothelial dysfunction. A number of recent papers provide some insight on the potential of PET/CT in cardiology and in the assessment of various cardiovascular diseases including various types of vasculitis and metabolic diseases.
Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).
Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has been developed at the University of Texas reactor. The facility produced good-quality radiographs and two-dimensional tomograms. Further developments have been recently accomplished. A computer software has been developed to automate and expedite the data acquisition and reconstruction processes. Volume tomographic visualization using Interactive Data Language (IDL) software has been demonstrated and will be further developed. Volume tomography provides the additional flexibility of producing slices of the object using software and thus avoids redoing the measurements.
Thirty-seven patients with histologic proof of cholangiocarcinoma at the confluence were examined by computed tomography (CT) to determine whether this examination is of value in the assessment of these patients for surgery and whether there are any features specific to this type of tumor. Thirty-two patients showed intrahepatic duct dilatation; six of these showed dilatation of ducts in one lobe only. Eighteen patients had intrahepatic low-attenuation areas, while eight had a mass lesion in the porta hepatis. The results of this study show that CT provides useful anatomic information preoperatively but that the appearances are nonspecific. Lobar atrophy is highly suggestive of hilar cholangiocarcinoma, either of long-standing or with unilateral portal venous involvement.
In order to evaluate the role of Computed Tomography (CT) in prediction of nature, staging and follow-up of soft-tessue tumors, the authors examined by CT 124 patients with soft tissue neoplasms who later underwent surgery (116 cases) or fine needle biopsy (8 cases). Comparison between CT and surgical or anatomical results showed that CT was able to correctly predict the benignancy or malignancy of the masses in 76% of cases but it was very seldom able to allow an hystological prediction. On the contrary CT was found to be a very useful tool for pre-therapeutic staging and follow-up of the tumors, because it gave many diagnostic information which influenced therapeutic choiches and strategies.
Computed tomography (CT) has already proved extremely effective both in cerebral and abdominal pathology. Several recent publications describing first heterogeneous series [1, 2, 7, 11-17], then studies of a single type of lesion [3-6, 8] have illustrated its usefulness in the study of bone lesions. This report deals with 41 cases of Ewing's sarcoma studied by CT at the Institut Gustave Roussy from October 1977 to July 1981, and tries to show both the limitations and indications of this technique for the diagnosis, treatment, and follow-up of Ewing's sarcoma as well as in the diagnosis of any eventual recurrence. (orig.).
In order to stress the role of computed tomography (CT) in the evaluation of benign spinal osteoblastoma, the authors examined by CT 10 patients with surgically and histologically proved osteoblastomas of the spine. Basing on surgical and histopathological findings CT proved to be a very important method for attesting the presence of the tumors (usually showed by radiographic examination), and specially for their staging and follow-up. CT in fact showed the real extent of the tumor into the spinal canal and towards the paraspinal soft tissues, and allowed the aerly detection of post surgical relapses. The authors conclude that CT is a primary diagnostic modality for preoperative planning and follow-up of benign osteoblastoma.
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter.
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).
Background: High-resolution computed tomography is the image procedure of choice in the evaluation of interstitial lung disease. Multidetector-row computed tomography provides the possibility of simultaneous reconstruction of thin and thick slices from the same raw data, acquired from one single series. Thus, it may be tempting to exclude the step-and-shoot series. Purpose: To compare high-resolution computed tomography (HRCT step-and-shoot) from single-slice CT (SSCT) and 16-channel multidetector CT (MDCT) in terms of visibility and motion artifacts, and to investigate whether thin images reconstructed from helical MDCT are equal to or better than conventional HRCT by SSCT in terms of visibility and motion artifacts. Material and Methods: 20 patients underwent HRCT step-and-shoot by SSCT (SSCT step-and-shoot) and MDCT (MDCT step-and-shoot), and a helical MDCT acquisition (MDCT helical). Images from four anatomical levels ...
Objectives: To investigate optical coherence tomography consistency on foveal thickness, foveal volume, and macular volume measurements in patients with and without diffuse diabetic macular edema. Introduction: Optical coherence tomography represents an objective technique that provides cross-sectional tomographs of retinal structure in vivo. However, it is expected that poor fixation ability, as seen in diabetic macular edema, could alter its results. Several authors have discussed the reproducibility of optical coherence tomography, but only a few have addressed the topic with respect to diabetic maculopathy. Methods: The study recruited diabetic patients without clinically evident retinopathy (control group) and with diffuse macular edema (case group). Only one eye of each patient was evaluated. Five consecutive fast macular scans were taken using Ocular Coherence Tomography 3; the 6 mm macular map ...
Studies were made on different types of packaging materials used for packing dried fish in the Philippines with a view to finding a suitable packaging material for irradiated dried fish. Among these packaging materials (polyethylene, cello/polyethylene, polyester/polyethylene, Kraft paper, polypropylene and interwoven polypropylene sacks), polyester/polyethylene laminate was the most resistant material against penetration by Dermestes carnivorous. No insect damage occurred on the dried fish packed in interwoven polypropylene lined with polyester/polyethylene laminate. The cost per sack of such packaging material having a capacity of 50-80 kg is US$ 0.50. The sack lined with polyester/polyethylene proved to be durable for surface transportation from Bacolod City to Manila (approx. 360 miles). Radiation treatment at 225 krad was effective against bacterial contamination but not effective in inhibiting ...
The changes in quality of irradiated spices, i.e., nutmeg (Myristica fragrans), black pepper and white pepper (Piper nigrum) stored in different indigenous packaging materials were evaluated. Packaging materials used were tin cans; tin can lined with polypropylene film, tin can lined with wrapping paper, woven polypropylene bag and woven polypropylene bag lined with polypropylene film. Packaging in woven polypropylene bag could cause significant changes in a_w-values and moisture contents of the spices. In the tin can, no significant change was found during storage. By applying a polypropylene film liner inside the plastic bag, the changes could be retarded. The other parameters observed, i.e. total plate count, total mould and yeast count and organoleptic scores of the samples were not significantly affected by the packaging method. A dose of 5 kGy could reduce the microbial load of the spices by about ...
In radiation processing of food, the product often has to be prepackaged to prevent microbial recontamination during and after irradiation. The packaging material is exposed to radiation during radiation processing and radiation stability is a key consideration in the selection of packaging materials. The effects of ionizing radiation on many food packaging materials at the dose levels recommended for food precessing can be minimized by selecting appropriate radiation resistant materials. It is important to select materials in which chemicals formed as a result of the radiation treatment do not migrate and interact with the food, affecting its organoleptic and toxicological aspects. It is also important to select materials in which the physical properties are not altered to the extent they cannot resist damage during commercial production, shipment and storage. Radiation treatment of food may be classified broadly into two ...
Radiation sterilization has several merits that it is a positively effective sterilization method, it can be used to sterilize low heat-resistant containers and high gas barrier films, and there is no possibility of residual chemicals being left in the packages. It has been commercially used in 'Bag in a Box' and some food containers. The #gamma# ray and an electron beam are commonly used in radiation sterilization. The #gamma# ray can sterilize large size containers and containers with complex shapes or sealed containers due to its strong transmission capability. However, since the equipment tends to be large and expensive, it is generally used in off production lines. On the other hand, it is possible to install and electron beam system on food production lines since the food can be processed in a short time due to its high beam coefficient and its ease of maintenance, even though an electron beam has limited usage such as sterilizing relatively thin materials ...
As the jump from 2D to 3D, seismic exploration lives a new revolution with the use of converted PS waves. Indeed PS converted waves are proving their potential as a tool for imaging through gas; lithology discrimination; structural confirmation; and more. Nevertheless, processing converted shear data and in particular determining accurate P and S velocity models for depth imaging of these data is still a challenging problem, especially when the subsurface is anisotropic. To solve this velocity model determination problem we propose to use reflection travel time tomography. In a first step, we derive a new approximation of the exact phase velocity equation of the SV wave in anisotropic (TI) media. This new approximation is valid for non-weak anisotropy and is mathematically simpler to handle than the exact equation. Then, starting from an isotropic reflection tomography tool developed at Lt-'P, we extend the isotropic bending ray ...
Abstract Salmonella Typhimurium and Listeria monocytogenes are major bacterial pathogens associated with poultry products. A controlled released ClO2 sachet applied with modified atmosphere packaging (MAP) was evaluated for its ability to control the growth of S. Typhimurium and L. monocytogenes on raw chicken breast during refrigerated storage. The fresh chicken samples were inoculated with one or the other of the pathogens at 104-cfu/g, and the packages (with and without ClO2 sachet) were flushed with ambient air or 30% CO2/70% N2 before sealing, and then stored at 4C for up to 21 days. The maximum reduction in MAP plus ClO2 (compared with MAP alone) was 0.68-log-cfu/g for S. Typhimurium and 1.87-log-cfu/g for L. monocytogenes. Color and pH changes of the chicken breast were observed at ...
Ionizing radiation, mainly in the form of #gamma#-rays from the radioisotope cobalt 60, is being used increasingly for the inactivation of contaminants in cosmetic and toiletry preparations. The treatment is applied to the product in its final pack, and therefore, it is important to recognize that the properties of the packaging materials could be affected, particularly if high radiation doses are used. The stability of a wide range of materials is discussed. The nature and extent of chemical and physical changes in plastics very much depends on the presence of antioxidants and other additives, and on the environmental conditions during irradiation. Some useful information is available from research into the use of radiation for the preservation of food - many films and laminates have been cleared for use in the United States. The low radiation doses used for the control of contaminants in cosmetic products are quite unlikely to cause changes in ...
Protecting sensitive items from undetected tampering in an unattended environment is crucial to the success of non-proliferation efforts relying on the verification of critical activities. Tamper Indicating Packaging (TIP) technologies are applied to containers, packages, and equipment that require an indication of a tamper attempt. Examples include: the transportation and storage of nuclear material, the operation and shipment of surveillance equipment and monitoring sensors, and the retail storage of medicine and food products. The spectrum of adversarial tampering ranges from attempted concealment of a pin-hole sized penetration to the complete container replacement, which would involve counterfeiting efforts of various degrees. Sandia National Laboratories (SNL) has developed a technology base for advanced TIP materials, sensors, designs, and processes which can be adapted to various future monitoring systems. The purpose of this technology ...
The PuO/sub 2/ cask or SP 5320-2 and 3 cask is designed for surface shipment of americium or plutonium. The cask design was physically tested to demonstrate that it met the criteria specified in US ERDA Manual Chapter 0529, and Chapter I, Interstate Commerce Commission. The package has been assessed for transport of up to 357 grams of plutonium (403 grams PuO/sub 2/ powder) and up to 176 grams of americium (200 grams AmO/sub 2/ powder), having a maximum decay heat of 203 watts. Criticality evaluation alone would allow the shipment as Fissile Class II but the radiation level of the cask, measured at the time of shipment, may exceed 50 mrem/h at the surface and require shipment as Fissile Class III. Sample calculations address only the more restrictive of the two materials, which in most cases is /sup 238/PuO/sub 2/.
SYVAC3 (Systems Variability Analysis Code, generation 3) is a computer program that implements a method called systems variability analysis to analyze the behaviour of a system in the presence of uncertainty. This method is based on simulating the system many times to determine the variation in behaviour it can exhibit. SYVAC3 specializes in systems representing the transport of contaminants, and has several features to simplify the modelling of such systems. It provides a general tool for estimating environmental impacts from the dispersal of contaminants. This report describes the use and structure of SYVAC3. It is intended for modellers, programmers, operators and reviewers who deal with simulation codes based on SYVAC3. From this manual they can learn how to link a model with SYVAC3, how to set up an input file, and how to extract results from output files. The manual lists the subroutines of SYVAC3 that are available for use by models, and describes their argument lists. It also ...
Limited field trial results of a heating oil additive package developed to minimize unscheduled maintenance indicate that it achieves its goal of keeping heating oil systems cleaner. The multifunctional additive package was developed to provide improved fuel oxidation stability, improved corrosion protection, and dispersency. This combination of performance benefits was chosen because we believed it would retard the formation of sludge, as well as allow sludge already present to be carried through the system without fouling the fuel system components (dispersency should keep sludge particles small so they pass through the filtering system). Since many unscheduled maintenance calls are linked to fouling of the fuel filtering system, the overall goal of this technology is to reduce these maintenance calls. Photographic evidence shows that the additive package not only reduces the amount of sludge formed, but even removes ...
The PLANCK SURVEYOR is a European Space Agency satellite mission to image the very faint anisotropies in the temperature of the Cosmic Microwave Background (CMB) radiation. Maynooth is actively participating in an international collaboration of scientists involved with the optical design of the High Frequency Instrument (HFI). This paper outlines research which has been undertaken in Maynooth concerned with numerical modelling of the optical characteristics of the multi-frequency array of detectors making up the HFI instrument. In the study the commercial software package ZEMAX was used to model the coupling of the focal plane HFI detectors to the PLANCK telescope. This package is particularly useful in the optical design of PLANCK because of the powerful optimisation features of the software. It is thus possible to readily determine the optimum positioning of the detectors in the focal plane of the telescope. Although the ...
All of the project work since the previous report has been on Phase 2B tasks. Therefore, this quarterly progress report summarizes the period's activities in Engineering, Procurement and Civil Construction. Engineering is 95% complete, but revisions and changes are still being incorporated particularly in the Instrument and Electrical areas. Procurement has only valves 4 in. and above yet to order to complete all major items purchased. The scheduled material curve was based on the original estimate of the job. The projected curve reflects the previous month's estimate. Construction of civil work is proceeding according to schedule in the field. The initial bid packages for the Mechanical General Contractor portion of the work have been reviewed and evaluated. Order placement is scheduled for the end of July. The Electrical package is due back from the bidders on July 6. It requires additional evaluation by BSC and DSO and will ...
Energy requirements and exergy inefficiencies for processing of malt drink were estimated for a Nigerian brewery. The process was divided into twenty-one basic unit operations and grouped into four main group operations: silo house, brew house, filter room and packaging house. The energy intensity for processing a batch of 9.8 tonnes brew grains to 562 hl of malt drink was estimated as 261.63 MJ/hl consisting of electrical (41.01%), thermal (58.81%) and manual (0.19%) of the total energy. The most energy intensive group operation was the Packaging House operation, followed by the Brew House operation with energy intensities of 223.19 and 35.94 MJ/hl, respectively. The exergy analysis revealed that the packaging house operation was responsible for most of the inefficiency (92.16%) followed by brew house operation (7.17%) and the silo house and filter room operations with less than 1% of the total exergy lost. The most exergy ...
Volatile compounds produced in flexible food packaging materials (LDPE, EVAc, PET/PE/EVOH/PE) during electron beam irradiation were isolated by purge and trap technique and identified by combined gas chromatography-mass spectrometry (GC/MS), after thermal desorption and concentration. For comparison purposes non-irradiated films were also studied. Film samples were irradiated at low (5 kGy, corresponding to cold pasteurization), intermediate (20 kGy, corresponding to cold sterilization) and high (100 kGy) doses. It was observed that a number of volatile compounds are produced after irradiation in all cases. Furthermore the amounts of all volatile compounds increase with increasing irradiation dose. Both primary (methyl-derivatives etc.) as well as secondary i.e. oxidation products (ketones, aldehydes, alcohols, carboxylic acids etc.) are produced upon irradiation. These products may affect organoleptic properties and thus shelf-life of prepackaged irradiated foods. ...
This experiment was done to determine the effects of irradiation on the physical properties of three kinds of laminated packaging materials, i.e. polypropylene-polypropylene, polypropylene-polyethylene, polyester-polyethylene. Observations were made on pinhole production, leakage, oil resistance, resistance against insect penetration, colour, odour tensile strength, elongation at break, seal strength and tear resistance. The samples were irradiated with doses of 0, 5 and 10 kGy, then stored at room temperature and examined after 0, 3, 6 and 12 months of storage. The results showed that irradiation doses up to 10 kGy, as well as storage up to 12 months, did not create pinholes, or leakage in pouches prepared from laminated films. The resistance of the films to oil and insect penetration, the colour, and the odour were also unchanged. Both irradiation and storage treatments had a significant effect on physical properties of the laminated films. In general, the ...
A new package for the air transport of hazardous materials is currently being developed in the Transportation Systems Department at Sandia National Laboratories. The baseline design has a unique impact limiter which uses layers of aluminum screen wire and aramid cloth fabric. A primary motivation for selecting this unusual combination of materials is the need for the impact limiter to not only limit the amount of load transmitted to the primary container but also remain in place during impact events so that it provides a thermal barrier during a subsequent fire. A series of uniaxial and confined compression tests indicated that the layered material does not behave like other well characterized materials. No existing constitutive models were able to satisfactorily capture the behavior of the layered material; thus, a new plasticity model was developed. The new material model was then used to characterize the response of air transport packages ...
The U.S. Department of Energy (DOE) Headquarters and associated contractors have developed an IBM PC-based software package that estimates costs, schedules, and public and occupational health risks for a range of mixed-waste management options. A key application of the software package is the comparison of various waste-treatment options documented in the draft Site Treatment Plans prepared in accordance with the requirements of the Federal Facility Compliance Act of 1992. This automated Systems Analysis Methodology consists of a user interface for configuring complexwide or site-specific waste-management options; calculational algorithms for cost, schedule and risk; and user-selected graphical or tabular output of results. The mixed-waste management activities modeled in the automated Systems Analysis Methodology include waste storage, characterization, handling, transportation, treatment, and disposal. Analyses of treatment options identified ...
The purpose of the trip was to visit Nobel Chemicals in Sweden and to confer with the Department of Transportation personnel in Sweden and in England on the technical and regulatory problems in the bulk shipping of the high explosives RDX and HMX. It is customary in the United States (US) to add isopropyl alcohol to the bulk shipment of water-wet high explosives RDX and HMX. The explosives are packed in cloth bags which are placed in plastic-lined fiber drums. The addition of alcohol presumably prevents mildewing of cloth bags and freezing of the wet explosives in cold weather. In Europe, however, these explosives are shipped in polyethylene-lined fiber drums with not less than 15% water only, even in cold weather. Water-wet frozen explosives have not proved to be any more sensitive than its unfrozen counterpart and no mildew problem has been encountered. It looks promising that the US Department of Transportation regulations can be changed to permit the bulk shipment of these ...
The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial pilot studies with ...
Thirty-five patients with temporal bone fractures were examined; the fractures were sometimes associated with dislocation of the assicular chain caused by road fatalities. Computed Tomography (CT) was performed either because of the presence of clinical symptoms associated with trauma of the temporal bone, because of a hemotympanum discovered during a CT scan of the brain. Thirty-three fractures were detected: 19 longitudinal, 6 transverse, and 8 complex. An incudostapedial dislocation was also detected, together with a displacement of a stapedial prosthesis from the lenticular process of incus, and 3 incus-malleus dislocation associated with fractures. High resolution CT allows the precise definition of the course of the fractures, of the associated dislocation of the ossicular chain, and of facial nerve lesion, thus allowing a more accurate surgical intervention. In the examination of the temporal bone, high resolution CT is preferible to pluridirectional ...
In earliest works devoted to proton computed tomography it was shown that the advantage of pCT image reconstruction appears when the energy is close to the Bragg peak region, since the proton passes the object. This effect provided by the Bragg peak makes the computerized tomography with protons possible. However, when decreasing the initial proton energy, with the increase of the irradiation dose, there are two effects that work simultaneously in opposite ways. First, the energy loss of a proton in an object becomes bigger at small initial energy. At the same time decreasing of the proton energy results in the increase of the energy straggling, requiring a larger number of protons. In this work the radiation dose dependence on the proton initial energy was studied using analytical formulas and computer simulations. The investigation determined that the radiation dose practically does not depend on the initial energy, except in the energy ...
Computed tomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computed tomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. Future applications of CT include the staging of mediastinal ...
Computed tomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computed tomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. Future applications of CT include the staging of mediastinal ...
In less than a decade computed tomography (CT scanning) had a profound impact on diagnostic radiology. Radiology of the orbit is no exception. As early as 1973, reports published in the radiological literature indicated that this new noninvasive imaging method was a highly effective way of demonstrating intraorbital mass lesions. As CT scanners became widely available, computed tomography became a significant adjunct to ophthalmological diagnosis. Today the main indications for CT scanning of the orbit are: (1) suspected mass lesions, most frequently presenting as exophthalmos, (2) orbital trauma, including foreign bodies, (3) some congenital anomalies, and (4) suspicion of extension into the orbit of extraorbital disease processes. Along with ultrasonography, another new noninvasive imaging technique, CT has replaced a number of more invasive and often less effective diagnostic methods, such as orbital pneumography, venography, and ...
Computerized Tomography has gained an important role in the diagnosis of the complications of prosthetic surgery of the abdominal aorta: the importance of such complications come from their frequency, which is proportional to the increasing number of interventions, and their severity. The authors investigated the CT patterns of the most frequent complications. 24 patients referred for strongly suspected postoperative complications were examined in 2 years: fever and leukocytosis (20 cases) and progressive anemia (4 cases) were the most frequent findings. The operation had been performed 7#+-# 12 weeks before (2 patients were excluded because surgery dated less than 3 weeks. 14 patients had infective complications: thickening (57%) and inhomogeneity (43%) of the periprosthetic wrap and ectopic gas bubble (78%) were the most frequent Computerized Tomography findings. The authors also observed 2 periprosthetic hematomas, 1 aneurysm relapse and 1 ...
Purpose: To describe the clinical aspects and evaluate optical coherence tomography of macular microholes. Methods: Seven patients were assessed (8 eyes) with microholes of the macula. All patients underwent complete eye examination, fundus photography, fluorescent angiography and OCT-3 imaging. Results: Ages ranged from 26 to 69 years. Six patients were female (85.7%) and five of them had microhole in the right eye. The presenting symptom was decrease in visual acuity (71.3%) and central scotoma in (14.3%). Five eyes (71.4%) had no defects shown by fluorescent angiography. A defect in the outer retina was demonstrated in all eyes on optical coherence tomography. The lesions were nonprogressive. Conclusion: Macular microholes are small lamellar defects in the outer retina. The condition is nonprogressive, generally unilateral and compatible with good visual acuity. Fundus biomicroscopy associated with an optical coherence ...
The environments on the drip shield and waste package outer barrier are controlled by the compositions of the waters that contact these components. the temperature (T) of these components, and the effective relative humidity (RH) at these components. Because the composition of the waters that are expected to enter the emplacement drifts (either by seepage flow or by episodic flow) have not been specified: well J13 water was chosen as the reference water (Harrar 1990). Section 6.2 discusses the accessible RH for the temperatures of interest at the repository horizon. Section 6.3 discusses the adsorption of water on metal alloys in the absence of hygroscopic salts. Because the temperatures of the DSs and the WPOBs are higher than those of the surrounding near-field environment, the relative humidity at the DSs and the WPOBs will be lower than that of the surrounding near-field environment. This difference is a result of the water partial pressure in the drift being ...
The purposes of this report are (1) to perform a Verification and Validation (V and V) test for the VIPEX(Vital-area Identification Package EXpert) software and (2) to improve a software quality through the V and V test. The VIPEX was developed in Korea Atomic Energy Research Institute (KAERI) for the Vital Area Identification (VAI) of nuclear power plants. The version of the VIPEX which was distributed is 3.2.0.0. The VIPEX was revised based on the first V and V test and the second V and V test was performed. We have performed the following tasks for the V and V test on Windows XP and VISTA operating systems: ? Testing basic functions including fault tree editing ? Testing all kind of functions ? Research for update from Visual BASIC 6.0 to Visual BASIC 2008
The Container Analysis Fire Environment (CAFE) computer code has been developed to model all relevant fire physics for predicting the thermal response of massive objects engulfed in large fires. It provides realistic fire thermal boundary conditions for use in design of radioactive material packages and in risk-based transportation studies. The CAFE code can be coupled to commercial finite-element codes such as MSC PATRAN/THERMAL and ANSYS. This coupled system of codes can be used to determine the internal thermal response of finite element models of packages to a range of fire environments. This document is a user manual describing how to use the three-dimensional version of CAFE, as well as a description of CAFE input and output parameters. Since this is a user manual, only a brief theoretical description of the equations and physical models is included.
The influence of electron-beam irradiation on mechanical properties of commercial multilayer flexible packaging materials based on coextruded and laminated polypropylene (PP), low-density polyethylene (LDPE), ethylene vinyl alcohol copolymer (EVOH) and poly(ethylene terephthalate) (PET), irradiated with doses up to 120 kGy, was studied. The tensile strength and elongation at break of the irradiated PET/PP film increase, while the penetration and sealing resistance decreased. In addition, the irradiated PET/LDPE/EVOH/LDPE film presented increase in the tensile strength on some radiation doses and decrease of the penetration and sealing resistance, except for sealing resistance at radiation dose of 15 kGy that resulted in a slight increase of ca 4%.
With conventional heating process, ultraviolet (UV) illumination, and microwave irradiation, we have successfully synthesized UV curable encapsulating adhesives with excellent gas barrier capabilities, good adhesive strength, moderate hardness, and high refractive indices. The experimental results manifest that the physical properties of lab-made encapsulating adhesives are highly dependent on their chemical structures and synthetic procedure. We also discover that the encapsulating adhesive prepared by microwave irradiation (i.e. encapsulating adhesive VI-MW) exhibits better adhesive strength and higher gas resistance than those prepared by conventional heating process and UV illumination. Furthermore, encapsulating adhesive VI-MW has also been applied for the package of organic light emi...
HLW disposal is one of the largest issue to utilize Nuclear power safely. In the past study, the concept, which buffer materials and Overpacked waste were transported into underground respectively, have shown. The concept of pre-assembled engineered barrier has advantage to simplify the logistics and emplacement procedure, however there are difficulties to support heavy weight of pre-assembled package by equipment under the condition of little clearance between tunnel and package. In this study, Combination of air bearing and two degree-of-freedom wheels were suggested for transportation, and air jack was suggested for unloading and emplacement system. Also, whole system for transportation and emplacement procedure was designed, and Scale model test was examined to evaluate the feasibility of these concept and functions. (author)
We report on the software aspects of the development of a switch-based data acquisition system at Fermilab. This paper describes how, with the goal of providing an integrated systems engineering'' environment, several powerful software tools were put in place to facilitate extensive exploration of all aspects of the design. These tools include a simulation package, graphics package and an Expert System shell which have been integrated to provide an environment which encourages the close interaction of hardware and software engineers. This paper includes a description of the simulation, user interface, embedded software, remote procedure calls, and diagnostic software which together have enabled us to provide real-time control and monitoring of a working prototype switch-based data acquisition (DAQ) system.
We report on the software aspects of the development of a switch-based data acquisition system at Fermilab. This paper describes how, with the goal of providing an ``integrated systems engineering`` environment, several powerful software tools were put in place to facilitate extensive exploration of all aspects of the design. These tools include a simulation package, graphics package and an Expert System shell which have been integrated to provide an environment which encourages the close interaction of hardware and software engineers. This paper includes a description of the simulation, user interface, embedded software, remote procedure calls, and diagnostic software which together have enabled us to provide real-time control and monitoring of a working prototype switch-based data acquisition (DAQ) system.
Effects of #gamma#-irradiation on synthetic polymers and paper used as packaging materials for irradiated food have been studied by NMR. Polystyrene, polybutadiene and some copolymers were studied before and after the #gamma#-irradiation treatment and in the presence or absence of antioxidants and stabilisers. In the absence of additives, the effect of #gamma#-irradiation on polystyrene is negligible even irradiating at high doses. In turn, the role of antioxidants and stabilisers is crucial in polybutadiene and butadiene-containing copolymers. Wood pulp paper was also studied by NMR. Preliminary measurements on #gamma#-irradiated wood pulp sheets show a shortening in the T_2 relaxation time component due to the bound water, i.e. some of the bound water is lost. (author)
Conversion of the microprocessors and software for the Mold Heating and Cooling (MHAC) pump package control systems was initiated to allow required system enhancements and provide data communications capabilities with the Plastics Information and Control System (PICS). The existing microprocessor-based control systems for the pump packages use an Intel 8088-based microprocessor board with a maximum of 64 Kbytes of program memory. The requirements for the system conversion were developed, and hardware has been selected to allow maximum reuse of existing hardware and software while providing the required additional capabilities and capacity. The new hardware will incorporate an Intel 80286-based microprocessor board with an 80287 math coprocessor, the system includes additional memory, I/O, and RS232 communication ports.
Abstract Microbiological quality and biophenol content evolution was studied in minimally processed Thassos cv table olives by hot air dehydration under mild conditions (40C, 24-h, aw-=-0.893) and storage under characteristic packaging conditions (vacuum, 100% N2 and air) at 4 and 20C over a period of 180 days. No salt was used in the production line or packaging. The undesirable microorganisms (Enterobacteriaceae, Staphylococcus aureus, Bacillus, Clostridium) were undetectable until the end of the storage period. Also, modified atmospheres prevented fungal growth at both temperatures apart from the samples stored in air, in which Penicillium and Aspergillus spp. were identified. At 20C, a coexistence of mesophilic bacteria and yeasts occurred. At 4C, yeasts were the predominant microflora...
An Effect of pinhole(perforation or pit penetration) that might be formed outside the package on the nuclide leaching from paraffin waste form was investigated. In case of single pinhole, the leached mass and cumulative fraction leached (CFL) increased with the larger diameter of pinhole, but they were not in direct proportion to the size or area of pinhole. If the total area of multiple pinholes was fixed, the leached mass showed a tendency to increase as each size was smaller and the number was more. It was also found that the leached mass was not in direct proportion to the number of pinhole in case of constant size. In order to analyze the test results, the shrinking core model(SCM) was derived from the diffusion-controlled dissolution reaction and compared with previous diffusion model.
Thin films of sodium montmorillonite clay and cationic polyacrylamide were grown on a polyethylene terephthalate film using layer-by-layer assembly. After 30 clay-polymer layers are deposited, with a thickness of 571 nm, the resulting transparent film has an oxygen transmission rate (OTR) below the detection limit of commercial instrumentation (< 0.005 cc/m{sup 2}/day/atm). This low OTR, which is unprecedented for a clay-filled polymer composite, is believed to be due to a brick wall nanostructure comprised of completely exfoliated clay in polymeric mortar. With an optical transparency greater than 90% and potential for microwaveability, this thin composite is a good candidate for foil replacement in food packaging and may also be useful for flexible electronics packaging.
This document describes payload control at LLNL to ensure that all shipments of CH-TRU waste in the TRUPACT-II (Transuranic Package Transporter-II) meet the requirements of the TRUPACT-II SARP (safety report for packaging). This document also provides specific instructions for the selection of authorized payloads once individual payload containers are qualified for transport. The physical assembly of the qualified payload and operating procedures for the use of the TRUPACT-II, including loading and unloading operations, are described in HWM Procedure No. 204, based on the information in the TRUPACT-II SARP. The LLNL TRAMPAC, along with the TRUPACT-II operating procedures contained in HWM Procedure No. 204, meet the documentation needs for the use of the TRUPACT-II at LLNL. Table 14-1 provides a summary of the LLNL waste generation and certification procedures as they relate to TRUPACT-II payload compliance.
Approximately 95% of the world`s integrated chips are packaged using a hot, high pressure transfer molding process. The stress created by the flow of silica powder loaded epoxy can displace the fine bonding wires and can even distort the metalization patterns under the protective chip passivation layer. In this study the authors developed a technique to measure the mechanical stress over the surface of an integrated circuit during the molding process. A CMOS test chip with 25 diffused resistor stress sensors was applied to a commercial lead frame. Both compression and shear stresses were measured at all 25 locations on the surface of the chip every 50 milliseconds during molding. These measurements have a fine time and stress resolution which should allow comparison with computer simulation of the molding process, thus allowing optimization of both the manufacturing process and mold geometry.
The LHCb experiment has chosen to use the SAM framework (Service Availability Monitoring Environment from EGEE-II) [1] make extensive tests of the LHCb environment at all the accessible grid resources. The availability and the proper definition of the local Computing and Storage Elements, user interfaces as well as the WLCG software environment are checked. The SAM framework is also used to pre-install the LHCb applications in the shared software area provided by each site. The deployment of the LHCb applications is based on a python tool developed inside the experiment. It is used for software management including incremental installation of interdependent packages and clean package removal. After the application software is installed a validation test of the whole MC chain is run. According to the results of the experiment specific SAM tests, the sites are (re)integrated into the LHCb production system managed by DIRAC [2]. The possibility of ...
A parachute system was designed and prototypes built to deploy a telemetry package behind an earth-penetrating weapon just before impact. The parachute was designed to slow the 10 lb. telemetry package and wire connecting it to the penetrator to 50 fps before impact occurred. The parachute system was designed to utilize a 1.3-ft-dia cross pilot parachute and a 10.8-ft-dia main parachute. A computer code normally used to model the deployment of suspension lines from a packed parachute system was modified to model the deployment of wire from the weapon forebody. Results of the design calculations are presented. Two flight tests of the WBS were conducted, but initiation of parachute deployment did not occur in either of the tests due to difficulties with other components. Thus, the trajectory calculations could not be verified with data. Draft drawings of the major components of the parachute system are presented.
The analysis of transmission line faults is essential to the proper performance of the power system. It is required if protective relays are to take the appropriate action and in monitoring the performance of relays, circuit breakers, and other protective and control elements. The detection and classification of transmission line faults is a fundamental component of such fault analysis. Another application of fault analysis is in software packages for automated analysis of digital fault recorder (DFR) files. Recently, such a package, called DFR Assistant, was developed for substation applications. This program can be installed locally in a substation, in which case it is connected directly to the DFR via a high speed parallel link, or it can be installed at a central station, in which case it can be configured to automatically analyze events coming from all DFRs.
A computational environment, as a set of MapleV R.3 routines for doing symbolic calculations in Quantum Field Theory, is presented. The Q F T package`s routines extend the standard MapleV computational domain by introducing representations for anti commutative and noncommutative objects, tensors, spinors and gauge fields, as well as related objects and procedures (Dirac matrices, differential operators, functional differentiation w.r.t indexed fields, sum rule for repeated indices, etc.). Furthermore, the Q F T routines permit the user-definition of algebra rules for the commutation/ anti commutation of operators, to be taken into account during the calculations. (author) 2 refs.
We present a novel preparation method for studies of in vitro reconstituted mitotic chromosomes from Xenopus laevis egg extracts. This method involves a gentle adsorption of chromosomes from the extracts using surface affinity enrichment, followed by plunge freezing, freeze-substitution and cryo-embedding before examination by EM tomography. For comparison, chromosomes were also prepared by a conventional method, which included immobilization of chromosomes in agarose and a room-temperature dehydration (embedding) protocol. Three-dimensional reconstructions showed that samples prepared with the new method have a greater interconnectivity of sub-structural features and a higher compaction ratio together with an apparently less perturbed chromatin structure than those prepared using the conventional approach. The implications of the new method for the preparation of other difficult samples and additional application possibilities are discussed.
The direct injection of steam into a water pool is a method of heat transfer used in many process industries. The amount of research in this area however is limited to the nuclear industry, with applications relating to reactor cooling systems. Electrical resistance tomography (ERT), a low cost, non-invasive and which has high temporal resolution characteristics, can be used as a visualization tool for the resistivity distribution for the steam injection into water pool such as IRWST. In this paper, three dimensional resistivity distribution of the process is obtained through ERT using iterative Gauss-Newton method. Numerical experiments are performed by assuming different resistive objects in the water pool. Numerical results show that ERT is successful in estimating the resistivity distribution for the injection of steam in the water pool
We have developed a method for the synthesis of C-11 iodoantipyrine. Carbon-11-labeled methyl iodide, prepared from /sup 11/CO2, was used to methylate 3-methyl-1-phenyl-2-pyrazolin-5-one to form C-11 antipyrine. Following silica-gel column chromatography and iodination, radiochemical purity of the C-11 iodoantipyrine was more than 99.5%, with a 10% yield and a specific activity of 30 mCi/mumol. Preliminary animal studies showed complete cerebral extraction and local cerebral blood-flow values that were within 4.6% of those obtained using C-14 iodoantipyrine. The C-11 analog, with positron emission tomography, will facilitate local cerebral blood-flow studies in human subjects.
The diagnostic accuracy of sialography and ultrasonography (US) in the evaluation of parotid masses is evaluated. Furthermore the role of computed tomography (CT) in this pathology is discussed. In the personal experience US proved to be the best method in the recognition of a parotid tumor while sialography was superior in defining the intra or extraparotid site. The two investigations showed the same accuracy in the definition of benign or malignant nature of the mass. Therefore we consider US the only investigation in most istances; sialography could be performed when the site of the lesion is uncertain or an inflammatory lesion is suspected. CT is never the first investigation; its use is limited to a low number of cases, mainly for the evaluation of large masses and when the association US-sialography does not allow a sure diagnosis.
Six patients with diskitis following lumbar disk surgery were investigated by Computed Tomography (CT). Four patients underwent CT in a rather early phase of the disease (5-37 days after the onset of the symptoms): a posterior paravertebral fluid collection was always recognized, while the plain film was normal. Later on (2-4 months), the classical signs of diskitis were evident, with both CT and the plain film. The collection was always present at CT. A reintervention, performed on 3 patients, revealed the purulent content of the collections. It seems reasonable to suggest a relationship between the collection and the subsequent diskitis; the collection is probably an early sign of the disease. Its detection is of grat value, because it could allow an immediate and adequate therapy. The authors stress the usefulness of performing CT in an early phase on this kind of symptomatic patients.
Study Type - Therapy (case series)Level of Evidence 4 OBJECTIVE To present our experience of retroperitoneoscopic partial adrenalectomy (RPA) for small adrenal tumours, as with modern imaging methods small adrenal lesions are being diagnosed more commonly, and retroperitoneoscopic adrenal surgery for small adrenal tumours (PATIENTS AND METHODS We retrospectively reviewed the records of 389 consecutive retroperitoneoscopic adrenalectomies from September 2005 to December 2008, 88 of which were small adrenal tumours and treated by RPA. Ultrasonography and computed tomography (CT) were used in all patients before RPA, and magnetic resonance imaging or positron emission tomography/CT in some patients. We used RPA for adrenal tumours and total adrenalectomy for adrenal cancer. During the surgery...
A brief survey is presented of the methods of preparation and of the applications of radiopharmaceuticals labelled with short-lived positron radionuclides "1"1C, "1"8F, "1"3N and "1"5O which, thanks to their energy level schemes, short half-life and the 511 keV photon radiation energy are almost ideal tracers in modern nuclear medicine and pharmacology. In conjunction with computerized tomography, they represent one of the most sensitive diagnostic imaging methods, the so-called positron emission tomography. In addition, their incorporation in the molecule of a pharmaceutical does not change the biological and chemical properties of the original molecule unlike those of radiopharmaceuticals labelled with technetium, iodine, etc. (author). 125 refs.
A Quantitative Computed Tomography (QCT) method, simplifying the well-known technique proposed by Genant (1982) and applied to a standard third generation whole body CT scanner is described. This technique was applied in the measurement of the trabecular bone which has high sensitivity for metabolic changes. The BMC (Bone Mineral Content) measured in different groups of subjects (healthy postmenopausal patients versus women with postmenopausal osteoporosis) showed a highly significant difference (p<0.001). The precision of repositioning (coefficient of variation 1.8% to 2.3%, obtained in healty male patients) and the good, linear relationship computed from the phantom values, minimize measurement errors. Since this method is quickly applied and involves low-dose radiation-exposure, it could be introduced in the clinical study of metabolic bone diseases.
Positron emission tomography (PET) is the gold standard for non-invasive assessment of myocardial viability and allows accurate detection of coronary artery disease by assessment of myocardial perfusion. Magnetic resonance imaging (MRI) provides high resolution anatomical images that allow accurate evaluation of ventricular structure and function together with detection of myocardial infarction. Potential hybrid PET/MR tomography may potentially facilitate the combination of information from these imaging modalities in cardiology. Furthermore, the combination of anatomical MRI images with the high sensitivity of PET for detecting molecular targets may extent the application of these modalities to the characterization of atherosclerotic plaques and to the evaluation of angiogenetic or stem cell therapies, for example. This article reviews studies using MRI and PET in parallel to compare their performance in cardiac applications together with the ...
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed at the University of Texas TRIGA reactor. Extensive Monte Carlo design calculations were used to determine optimal design parameters of the neutron collimator system to avoid costly trial and error. Thermal neutron flux determined by gold foil activation is 5 {times} 10{sup 6} n/cm{sup 2}{center_dot}s at the primary imaging location with beam size of 22.5 cm in diameter. The collimation ratio can be varied from 125 to 235. The neutron-to-gamma ratio is 7.8 {times} 10{sup 6} n/cm{sup 2}{center_dot}mR. The facility has been tested for radiography and tomography applications and is now fully operational.
A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.
Hilar cholangiocarcinoma is associated with a dismal prognosis; however, curative resection may offer a chance of cure. Various factors should be considered in the surgical planning for curative resection. These factors include extent of bile duct involvement, relationship between portal vein and tumor involvement, diffuse hepato duodenal ligament infiltration, vascular invasion, lymph node metastasis, peritoneal seeding, and hepatic volume. Using high-quality volume data from multidetector-row computed tomography (MDCT) and adequate postprocessing images, radiologists can provide various types of information, imperative for curative resection of a hilar cholangiocarcinoma. This review illustrates the role of MDCT in the preoperative workup of hilar cholangiocarcinoma.
Purpose We evaluated low-contrast injection protocols for coronary computed tomography angiography (CTA) using a 64-detector scanner and the test bolus technique. Materials and methods We randomly assigned 60 patients undergoing coronary CTA to one of two contrast material (CM) injection protocols. For the lowcontrast dose protocol (Plow), the patients received injections of iohexol-350 [0.7 ml/kg body weight (BW)] during 9 s, and the test-bolus technique was used. Under the conventional protocol (Pconv), they received iohexol-350 (1.0 ml/kg BW) during 15 s, and bolus tracking was used. We compared the protocols for attenuation values in the ascending aorta and coronary arteries and for the amount of CM required. Results There was no significant difference in the mean CT attenuation of the...
Purpose Video-assisted thoracic surgery (VATS) has recently been adopted for complicated anatomical lung resections. During these thoracoscopic procedures, surgeons view the operative field on a two-dimensional (2-D) video monitor and cannot palpate the organ directly, thus frequently encountering anatomical difficulties. This study aimed to estimate the usefulness of preoperative three-dimensional (3-D) imaging of thoracic organs. Methods We compared the preoperative 64-row three-dimensional multidetector computed tomography (3DMDCT) findings of lung cancer-affected thoracic organs to the operative findings. Results In comparison to the operative findings, the branches of pulmonary arteries, veins, and bronchi were well defined in the 3D-MDCT images of 27 patients. Conclusion 3D-MDCT imag...
Herein we present an impact of diagnosis by enhanced multidetector-row computed tomography and magnetic resonance imaging for extrahepatic cholangiocarcinoma (ECC). Although the diagnosis against the longitudinal stromal extension and surrounding tissue invasion of ECC by multi detector row CT (MDCT) and MRI was very strict, we could not detect any superficial mucosal spread (SMS). Furthermore, the diagnosis of lymphnode metastasis by MDCT/MRI was miserable. We believe that misdiagnosis of SMS is permissible since positive mucosal but not stromal surgical margin was not a significant factor influencing the postoperative prognosis. However, further advances in imaging diagnosis for ECC is needed. (author)
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has been developed at the University of Texas reactor. The facility produced a good-quality radiographs and two-dimensional tomograms. Further developments have been recently accomplished. Further developments have been recently accomplished. A computer software has been developed to automate and expedite the data acquisition and reconstruction processes. Volume tomographic visualization using Interactive Data Language (IDL) software has been demonstrated and will be further developed. Volume tomography provides the additional flexibility of producing slices of the object using software and thus avoids redoing the measurements.
PurposeTo characterize the morphology of outer retinal holes caused by solar maculopathy, using spectral-domain optical coherence tomography (SD-OCT). DesignThis study is an observational case series. MethodsThe SD-OCT findings of 3 patients (6 eyes) with chronic solar maculopathy are presented. ResultsSD-OCT demonstrates a characteristic appearance of partial-thickness hole(s) in the outer retina at the fovea. In 3 of 6 eyes, there is 1 hole directly beneath the umbo. In the remaining 3 eyes, there are multifocal holes spread across the fovea. Holes in more restricted layers, as had been previously reported with time-domain OCT, were not seen. In addition, advanced visualization of SD-OCT data demonstrates a hyperreflective ring around the outer retinal hole. ConclusionsSD-OCT can be used...
Existing oil reservoirs might be more fully exploited if the properties of the flow of oil and water in porous media were better known. In laboratory experiments it is important to collect as much information as possible to make a descriptive model of the system, including position imaging and chemical binding information. This thesis develops nuclear methods for obtaining position image and chemical binding information from flow experiments of porous media. A combined positron emission tomography and single photon emission computed tomography system to obtain position images, and a time-differential perturbed angular correlation system to obtain chemical binding information, have been built and thoroughly tested. 68 refs., 123 figs., 14 tabs.
Colorectal cancer (CRC) is the most common cause of cancer death among Canadian non-smokers. Each year about 21,500 Canadians are diagnosed with CRC. Ninety percent of cases occur in people aged 50 years or older. An estimated 4,800 Canadian men and 4,100 Canadian women die each year from the disease. About 75% of all new CRC cases arise in people with no known risk factors. Computed tomography colonography (CTC), a cross-sectional imaging examination that permits complete structural examination of the colon, shows promise as a tool for CRC screening. This article reviews the rationale for CRC screening, currently recommended Canadian and American screening guidelines and screening tools, and current evidence supporting CTC as a CRC screening tool and its advantages over conventional screening methods. (author)
Colorectal cancer (CRC) is the most common cause of cancer death among Canadian non-smokers. Each year about 21,500 Canadians are diagnosed with CRC. Ninety percent of cases occur in people aged 50 years or older. An estimated 4,800 Canadian men and 4,100 Canadian women die each year from the disease. About 75% of all new CRC cases arise in people with no known risk factors. Computed tomography colonography (CTC), a cross-sectional imaging examination that permits complete structural examination of the colon, shows promise as a tool for CRC screening. This article reviews the rationale for CRC screening, currently recommended Canadian and American screening guidelines and screening tools, and current evidence supporting CTC as a CRC screening tool and its advantages over conventional screening methods. (author)
Computed Tomography (CT) of the spine was performed on 17 patients with myeloma in order to assess the role of the technique in recognizing and evaluating the extent of the lesions. Myelomatous lesions followed two patterns at CT: first of all, multiple focal lesions, whose density is either solid, liquid, or fatty; second, an extensive pattern involving the spongiosa of the vertebra, including the posterior arch. CT detected more lesions than conventional radiology; furthermore, the extent of the lesions was much better demonstrated by CT. CT should thus be performed: a) in case of pain and/or neurological findings in negative radiological examinations; b) to evaluate the extent of myelomatous lesions (mainly in the spine); c) in solitary myeloma CT may be performed on different bone segments with clinical symptomatology but normal X-ray findings.
Twenty-three patients with intracranial meningiomas were examined by means of magnetic resonance tomography (MRT). In 13 patients the paramagnetic contrast medium gadolinium DTPA was used. Meningiomas show only slight changes in signal intensity compared with brain in the spin-echo mode, the greatest contrast being found on photon density images (TR 1600 ms, TE 35 ms). In T1 images more than 50% of the patients showed a low signal margin between tumour and brain. Hyperostosis of the calvarium is easily recognised, but MRT is unreliable for showing tumour calcification. After intravenous injection of gadolinium DTPA, there was marked homogeneous uptake in the meningiomas. These signs are useful for the diagnosis of a meningioma by MRT. (orig.).
In 9 over 12 patients who underwent cardiac transplantation computed tomography was performed. In 5 of them CT was obtained also before the surgical treatment. In all patients angio-CT technique was performed, while the ECG-gated technique was employed only before surgery. CT shows changes in morphology of both atria but over all of the right one, and rotation of the heart on the longitudinal axis. The conditions of the pericardium are particulary well demonstrated: in 5 cases pericardial effusion was observed, 3 times localized and 2 times diffuse. Only in 1 patient a small thrombus in the right atrium was demonstrated. CT allows the possibility to obtain simultaneously information on mediastinum, lung and pleura. Pleural effusion, pulmonary infections and mediastinal complications are easily demonstrated.
Bone mineral content as determined by computerized tomography (CT) and mechanical strength on axial loading were compared in 36 cadaveric femur specimens. Based on the CT measurements of density and area, the mass of a transverse slice of the femur was estimated. Highly significant correlations were demonstrated between strength and cancellous bone density. Even higher correlations were revealed when the bone masses of the proximal and distal femoral areas were calculated. Based on these findings, an equal distribution of the effective mass of the femur was postulated. This hypothesis was confirmed in an experimental rotational model. The CT attenuation values were also correlated to direct measurements of bone mineral content, i.e. calcium. Moreover, the strength of different metal implants, commonly used in femoral neck fractures, were assessed in cadaver specimens. 134 refs., 13 figs., 12 tabs.
Fuji Computed Radiography (FCR) is a new system of digital radiography that is based on the latest computer technologies. We applied this FCR system to the X-ray diagnosis of the laryngeal disease. Twenty patients with various laryngeal diseases were evaluated by both FCR frontal tomography and conventional screen-film frontal tomography under the same exposure condition. Both tomograms were then compared on the subject of the clarity of delineation of laryngeal structures. As the result, FCR tomograms revealed the feature of the laryngeal lumen and cartilages more clearly than conventional tomograms. In addition, energy subtraction method, which is one of FCR image processing systems, was presented as a new technical procedure to extinguish cervical spine shadows in plain anteroposterior laryngeal X-photograph. We stress that FCR system is the suitable procedure for X-ray analysis of laryngeal diseases, especially in the region related with ...
A simple and efficient method for characterization of multidimensional Gaussian states is suggested and experimentally demonstrated. Our scheme shows analogies with tomography of finite dimensional quantum states, with the covariance matrix playing the role of the density matrix and homodyne detection providing Stern-Gerlach-like projections. The major difference stems from a different character of relevant noises: while the statistics of Stern-Gerlach-like measurements is governed by binomial statistics, the detection of quadrature variances correspond to chi-square statistics. For Gaussian and near Gaussian states the suggested method provides, compared to standard tomography techniques, more stable and reliable reconstructions. In addition, by putting together reconstruction methods for Gaussian and arbitrary states, we obtain a tool to detect the non-Gaussian character of optical signals.
A prospective comparative study with pathology was performed to assess the clinical value of Computed Tomography (CT) and endoscopic ultrasound (EUS) for nodal staging in lung cancer. A total of 329 nodal stations were dissected or sampled and 755 lymph nodes were examined at histology. On a pre-station basis, CT had greater sensitivity (74%) than EUS (56%), but EUS was more specific (83% versus 93%). The accuracy rates of the two techniques were similar. In conclusion, endoscopic ultrasound should be part of a routine preoperative diagnostic approach to non-small-cell lung cancer., because of its high specificity. Results can be improved when EUS and CT are combined., which suggests that these imaging modalities should be used together in selected patients for the noninvasive staging of non-small-cell lung cancer to identify local lymphatic spread.
The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10{sup 6} n/cm{sup 2} s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)
The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10"6 n/cm"2 s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)
Computed tomography (CT) has been incorporated in an industrial Diode-Array Digital Radiography (DADR) system. An input data size of 512 pixel points x 400 projections yielded a 400x400 output image matrix. Reconstruction algorithms used are the filtered backprojection (FBP) and the direct Fourier reconstruction (DFR). Various filters were used in the FBP reconstruction process and their effects on image quality were evaluated. A spatial resolution of 100 {mu}m was measured with a block of plates and a minimum detectable feature size in the range of 10-100 {mu}m was measured using thin wires. Industrial specimens imaged have included ceramic samples, ball bearings and integrated circuits. A number of engineering problems have been solved, such as adjustment of the X-ray source, centering of the rotator spindle in the view field and beam-hardening corrections. (orig.).
A chemical equilibrium model is used, implemented in a compact FORTRAN package called HITEQ, to investigate possible mineral deposition related to prereinjection treatment of Cerro Prieto brines for silica removal. Large saturation ratios of the treated brines with respect to several minerals are indicated by these computations. As a remedy, an inexpensive CO/sub 2/ removal scheme aimed at inhibiting carbonate mineral precipitation is proposed. This scheme is quantitatively discussed with the aid of HITEQ. It is concluded that the proposed treatment is both technically and economically feasible.
Overview Package  Class Use Tree Deprecated Index Help  PREV CLASS  NEXT CLASS FRAMES   NO FRAMES SUMMARY:  INNER | FIELD | CONSTR | METHOD DETAIL:  FIELD | CONSTR | METHOD gov.nih.nci.dc.builder Interface SAXFilter All Superinterfaces: org.xml.sax.XMLFilter,
Overview Package  Class Use Tree Deprecated Index Help  PREV CLASS  NEXT CLASS FRAMES   NO FRAMES SUMMARY:  INNER | FIELD | CONSTR | METHOD DETAIL:  FIELD | CONSTR | METHOD gov.nih.nci.dc.bean Class ImageIDParseBean java.lang.Object | +--java.util.Dictionary
Although statistical design is one of the oldest branches of statistics, its importance is ever increasing, especially in the face of the data flood that often faces statisticians. It is important to recognize the appropriate design, and to understand how to effectively implement it, being aware that the default settings from a computer package can easily provide an incorrect analysis. The goal of this book is to describe the principles that drive good design, paying attention to both the theoretical background and the problems arising from real experimental situations. Designs are motivated t
The application of various signal processing methods to extract energy storage information from plasma diamagnetism sensors occurring during physics experiments on the Tandom Mirror Experiment-Upgrade (TMX-U) is discussed. We show how these processing techniques can be used to decrease the uncertainty in the corresponding sensor measurements. The algorithms suggested are implemented using SIG, an interactive signal processing package developed at LLNL.
Modec International Inc has selected Siemens Water Technologies to provide sea-water reverse osmosis (SWRO) systems for several floating, production, storage and offloading (FPSO) vessels that are to be operated in deep-water locations. Siemens is also supplying a wastewater reuse system to one of Brazils largest refineries.
Certification as applied to existing computer codes includes the verification and validation process, placing the code in configuration control, establishing user qualification standards and training requirements. All software intended for use in critical calculations must be certified. This report is intended to fulfill the requirements for the certification of the SHIELD, SHLDED, GEDIT, GENPRT, FIPROD, FPCALC, and PROCES modules of the SHIELD system built February, 1992, by W.S. Parks. These modules are used for burnup, cooling, separate, and edit calculations.
The safety analysis checklist scope and the criteria of key parameters needed to be checked for Daya bay reload cycles are introduced. The INCORE code package was used for the safety evaluation of Daya bay unit 2 cycle 2. The method and the contents can not only be applicable for Daya Bay reload cycles but also for Qinshan 600 MW and Qinshan 300 MW reload cycles.
The Monsanto Chemical Company operates a plastics and resins plant located in Addyston, Ohio. The process equipment requires routine rinsing with technical grade acetone between batches. Due to the volumes of spent acetone generated and the associated RCRA hazardous waste regulations, the plant sought to recycle and reuse the acetone to reduce the purchase cost of virgin acetone and the cost of spent acetone disposal. One of the first options explored was package unit distillation units. The cost of these units was in the $20--$30,000 range in 1989 dollars. Even though the cost of a package unit was not deemed unreasonable, there were additional costs and concerns that led to elimination of this option. The unit would have required additional manpower to operate and maintain, i.e., at least a fraction of an operator and mechanic. For plant safety reasons, it was desired to operate this package unit outside the production ...
The upgraded CDF II detector has collected first data during the initial operation of the Tevatron accelerator in Run II. The simulation of the CDF electromagnetic and hadronic central and upgraded plug (forward) calorimeter is based on the Gflash calorimeter parameterization package used within the GEANT based detector simulation of the Run II CDF detector. We present the results of tuning the central and plug calorimeter response to test beam data.
As a part of a phenomenological model, a method for simulating the wall/jet interaction in a direct injection diesel engine is proposed. The method is based on the application of the momentum conservation equation in the different directions in which the wall jet is spread, and takes into account both the interaction with the combustion chamber geometry and with swirl. It takes as initial conditions the results of calculating the free jet, which is divided into packages. The predictions provide good agreement with those by other researchers. (author).
BackgroundIn an effort to promote healthy ageing and preserve health and function, the government of Chile has formulated a package of actions into the Programme for Complementary...Full Text Available
This document describes testing of OSI products conducted at Argonne National Laboratory. Sun, IBM, and Clsco hardware platforms were used. Various software packages that implement file transfer and gateway applications were evaluated. The OSI model and GOSIP compliance are briefly discussed. Technical details on OSI addressing and routing are presented. The relationship of this testing to other OSI activities at Argonne and to activities of the national networking community is discussed. Mention is also made of the relationship of DECnet Phase V transition issues.
The reconstruction of coronal and Sagittal Image of Brain C. T. is helpful to diagnosis of Brain. Three Dimensional Reconstruction software package allows to display three dimensional Image clerived from a series of Horizontal, Sagittal and Coronal Brain C. T. images. It useful in determine approach of operation, to define portals of deep radiation therapy.
...and supply ensuring better food quality for the consumer developing safer and more flexible food production processes and technologies raw materials for food production; production and processing systems; by-products and wastes from fisheries and agro-industry; new food sources; packaging systems; quality monitoring; traceability Food contamination detecting and eliminating infectious and toxic agents throughout the food chain establishing the hazards and origins of food contaminants producing food more safely rapid ...
Records of the 8. ITER Council Meeting (IC-8), held on 26-27 July 1995, in San Diego, USA, and the 9. ITER Council Meeting (IC-9) held on 12-13 December 1995, in Garching, Germany, are presented, giving essential information on the evolution of the ITER Engineering Design Activities (EDA) and the ITER Interim Design Report Package and Relevant Documents. Figs, tabs.
We report on the calculation of multi-loop Feynman integrals for single-scale problems by means of difference equations in Mellin space. The solution to these difference equations in terms of harmonic sums can be constructed algorithmically over difference fields, the so-called {pi}{sigma}{sup *}-fields. We test the implementation of the Mathematica package Sigma on examples from recent higher order perturbative calculations in Quantum Chromodynamics. (orig.)
FastBit is a software package designed to meet the searching and filtering needs of data intensive sciences. In these applications, scientists are trying to find nuggets of information from petabytes of raw data. FastBit has been demonstrated to be an order of magnitude faster than comparable technologies. In this brief report, we highlight how we work with a visualization team, a network security team and a DNA sequencing center to find the nuggets in their data.
Characterization of the electron beam's properties will be a major task after the upgrade of the Los Alamos Free-Electron Laser (FEL) Facility with a photoelectric injector (PEI) and increased acceleration capability to 40 MeV. Adjustments to the previous diagnostics package that address the lower beam emittance, higher energy, and wakefield source reduction issues will be discussed. 6 refs., 8 figs., 1 tab.
The vibration behavior of turbomachine bladings is described, and the behavior of different kinds of coupled low pressure stages was experimentally investigated. Besides purely stationary flow conditions, conditions were also considered where pulsating fl...
Electrochemical cyclic potentiodynamic polarization (CPP) experiments were performed on several candidate high-performance waste package container materials to evaluate their susceptibility to localized corrosion in aqueous environments relevant to the potential underground high-level nuclear waste repository. This paper presents the results of this study showing the effects of chloride ion (Cl) concentrations, pH, temperature, and electrochemical potential scan rate on the pitting corrosion behavior of these materials.
The halogenated benzimidazoles BDCRB (2-bromo-5,6-dichloro-1-β-d-riborfuranosyl benzimidazole riboside) and TCRB (2,5,6-trichloro-1-β-d-riborfuranosyl benzimidazole...Full Text Available
AGROSTER Co irradiates food packaging material and some types of spices for the meat industry. The step by step strategy of AGROSTER has been very successful. In the last year, its gamma facility was used as much as possible to irradiate food items. The government of Hungary has recognized the benefit of this technology and has given financial assistance to establish a large commercial gamma irradiator in Budapest.
The present report is final report from a study on characterisation of radioactive waters in the Nordic countries. The study has mainly been focused on long-lived low and intermediate level radioactive waste. Methods to measure or estimate the activity content and the general composition are discussed. Recommendations are given regarding characterisation of waste under treatment and characterisation of already produced waste packages. (au).
We discuss the calculation of two-point three-loop functions with an arbitrary number of massive propagators and one large external momentum. The relevant subdiagrams are generated automatically. The resulting massless two-point integrals and massive tadpoles are transformed on-line to FORM-expressions ready to be used by existing FORM packages which calculate them analytically. As an example we compute the quartic mass corrections to the photon polarization function. (orig.).
The advance in the analysis of very small amount (<= 1#alpha#/cm"2h) of #alpha#-emitters in the cited materials is reviewed. The review, for which 75 references are listed, covers the period from January, 1978, to June, 1982. The use of #alpha#-ray counting, #alpha#-ray spectrometry, #gamma#-ray spectrometry, neutron activation analysis and mass spectrometry is discussed, and their relative merit and limitation are outlined. (J.P.N.).
We propose a system for the on-line monitoring of short and medium term radioactive waste repositories. Such a system is distributed, fine-grained, robust, reliable, and must be based on low-cost components. It could, in principle, open new perspectives on the modality of waste packaging and storage. In particular we propose to employ a new family of cheap and powerful micro sensors to be placed in shape of a fine grid around each single drum. (authors)
OBJECTIVES: To assess the suitability of analyzing functional images of brain serotonin (5-HT) synthesis with statistical parametric mapping (SPM), and to investigate further possible sex-related regional...Full Text Available
A review is made of the various brain imaging agents utilised in the post few years with their own characters and respective advantages: cerebral blood volume tracers, non diffusible tracers, diffusible tracers among which gases and lipophilic agents. Our results with IAMP and SPECT are presented in two different clinical application fields: normal pressure hydrocephalus and cerebral ischemia.
A review is made of the various brain imaging agents utilised in the post few years with their own characters and respective advantages: cerebral blood volume tracers, non diffusible tracers, diffusible tracers among which gases and lipophilic agents. Our results with IAMP and SPECT are presented in two different clinical application fields: normal pressure hydrocephalus and cerebral ischemia.
Scintigraphic imaging of dementia relies today essentially on the study of brain Single Photo Emission Computed Tomography (SPECT) perfusion, after intravenous injection of 99mTc radio-pharmaceutic. This paper is based on the guidelines published in October 2001 by the European Association of Nuclear Medicine (http://eanm.org/). (author)
70 patients with squamouscell carcinoma of larynx and hypopharynx were examined by computed tomography; the TNM staging of tumors by CT, by endoscopy and by surgical operation was reviewed. CT proved to be reliable both to recognize the presence of neoplasms, with the exception of those very superficial, and their deep spreading to preepiglottic and paralaryngeal spaces, to the soft tissues of the neck and to the cartilages. Therefore CT is the examination of choice in laryngeal neoplasms staging, because it precisely completes the clinical and endoscopical informations.
Cardiac tumours may display diverse symptoms through potential involvement of any structure of the heart. We describe a case of a highly malignant thymoma with involvement of different cardiac structures with important haemodynamic compromise. With the high sensitivity of transthoracic echocardiography for detection of intracardiac masses, computed tomography and magnetic resonance add essential structural preoperative information on the tumour and surrounding tissue as vessels, pleura, lung and mediastinum.
In developing new receptor-site specific brain imaging agents labeled with I-123 for single photon emission computed tomography (SPECT), an analog of raclopride, 3-["1"2"5I]-iodo-N-[(1-ethyl-2-pyrrolidinyl)-methyl]-2-hydroxy-6-me-thoxy benzamide (IBZM), was prepared using a method similar to that reported for raclopride and its derivatives. (author).
Positron emission tomography (PET) and magnetic resonance imaging (MRI) studies were performed on a case of neuro-Behcet's syndrome. In accordance with the clinical signs, FDG PET (using /sup 18/F-labeled 2-F-2'-desoxyglucose) revealed disseminated storage defects in the cerebrum and cerebellum. Focal regions of enhanced signal intensity were demonstrated in the parietal white matter of the cerebrum in T2-weighted images and in the brain stem by MRI. (orig.).
To optimize the emergency care of patients with multiple injuries, a special emergency room with integrated radiological equipment has been developed. It consists of a linear array of a computed tomography system, a mobile C-arm with an integrated scattered radiation grid for conventional films and a C-arm fluorographic system. The intent is to avoid delay caused by transport and repositioning of the patient. It enables all necessary diagnostic procedures to be performed within a minimal amount of time. (orig./MG).
A thermal neutron imaging facility for computed tomography and real-time neutron radiography is being developed at the University of Texas at Austin. The TRIGA reactor is a graphite-reflected Mark It pool-type research reactor. The neutron imaging facility will use beam port, which is at one end of a through part. Monte Carlo calculations were used to design the neutron collimator for this facility.
Distribution of Lipiodol within hepatic tumor was evaluated using serial computed tomography. Imagistic Lipiodol transition into the tumor via hepatic artery was slower than that of water soluble contrast medium, spreading to central part first and turn to peripheral part of the tumor. This method was thought to be useful to clarify Lipiodol distribution in hepatic tumor and to decide the method or necessity of additional trans-arterial therapy. (author).
A possibility of short-lived isotopes production in inter-tank section between the first and the second drift tube tanks (20.45 MeV) in INR linac is considered. At the initial stage the main efforts are concentrated on production of fluorine-18 used for positron emission tomography. The results of beam forming calculations, target heating calculations, equipment activation calculations as well as installation configuration and design are presented.
Out of one hundred cases of the urinary bladder abnormalities examined by this method, CT staging and pathological correlations were investigated in 61 cases of the urinary bladder neoplasms. Accuracy of CT staging was 87% in this series with possible exception of 6 cases involving the bladder base and dome. CT scan using this method is the most reliable procedure to determine the treatment modalities of the urinary bladder tumors.
As a self-teaching tool, this illustrated guide facilitates home study of the complexities of thoracic CT's. Over 400 illustrations and accompanying copy are used to provide a basis for understanding the CT appearances of disease processes and a comparison of CT lookalikes. It updates new and interesting developments in the format of case presentations.
Intrahepatic cholangiocarcinoma is an uncommon tumor as primary hepatic neoplasm. Five cases of cholangiocarcinoma, mass forming peripheral type, are reported about its CT findings. They were manifested as a poorly marginated low density mass with a irregular stellate area. In one case, a cut section of the gross specimen following surgery showed a central callagenous scar and vessels within the necrotic tumor. (author).
A 21-year-old male patient was transferred to the emergency room of our hospital after suffering seat belt abdominal injury in a traffic accident. Abdominal computed tomography revealed a massive hematoma...Full Text Available
Helical tomotherapy presented many unique dosimetric challenges and solutions during the initial commissioning process, and some of them are presented. The dose calculation algorithm is convolution/superposition based. This requires that the energy fluence spectrum and magnitude be quantified. The methodology for doing so is described. Aspects of the energy fluence characterization that are unique to tomotherapy are highlighted. Many beam characteristics can be measured automatically by an included megavoltage computed tomography imaging system. This greatly improves data collection efficiency.
Computed tomography was performed on 5 patients with chronic cerebral paragonimiasis. CT showed solitary or multiple, amorphous, round, or oval calcifications, and ventricular enlargement in all 5 cases. A large low-density area is also found in 4 of the 5 cases. These CT findings are compatible with previously reported findings of simple X-ray films of the skull, pneumoencephalography, and pathological studies. (author).
Primary peritoneal malignant mixed mullerian tumors are very rare. We report the case of a patient presenting with pain in the right upper quadrant of the abdomen and in whom the physical examination demonstrated a peritoneal mass. Computed tomography (CT) confirmed the presence of a mass, with invasion of adjacent organs.
The authors present an unusual case of a patient with orbital metastases from renal carcinoma involving the extra ocular muscles bilaterally. The importance of computed tomography for the differential diagnosis with other orbital lesions is emphasized. (author)
An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)
The software package VIBA-lab1, which incorporates PIXE and RBS energy spectra simulation has now been extended to include the simulation of elemental maps from 3D structures. VIBA-lab1 allows the user to define a wide variety of experimental parameters, e.g. energy and species of incident ions, excitation and detection geometry, etc. When the relevant experimental parameters as well as target composition are defined, the program can then simulate the corresponding PIXE and RBS spectra. VIBA-LAB2 has been written with applications in nuclear microscopy in mind. A set of drag-and-drop tools has been incorporated to allow the user to define a three-dimensional sample object of mixed elemental composition. PIXE energy spectra simulations are then carried out on pixel-by-pixel basis and the corresponding intensity distributions or elemental maps can be computed. Several simulated intensity distributions for some 3D objects are demonstrated, and simulations obtained ...
Control of thermal expansion is often necessary in the design and selection of electronic packages. In some instances, it is desirable to have a coefficient of thermal expansion intermediate between values readily attainable with single or two phase materials. The addition of a third phase in the form of fillers, whiskers, or fibers can be used to attain intermediate expansions. To help design the thermal expansion of multiphase materials for specific applications, a closed form model has been developed that accurately predicts the effective elastic properties of isotropic filled materials and transversely isotropic lamina. Properties of filled matrix materials are used as inputs to the lamina model to obtain the composite elastic properties as a function of the volume fraction of each phase. Hybrid composites with two or more fiber types are easily handled with this model. This paper reports that results for glass, quartz, and Kevlar fibers with beta-eucryptite ...
This paper introduces the solid radwaste management system, treatment methods and its continuous improvement during the past 9 years in Guangdong Daya Bay Nuclear Power Station (GNPS). GNPS has paid great attention and made a lot of efforts to implement the principle of waste minimization with source control, improvement of treatment process and strict management, so the output of solid radwastes has annually decreased since 1994. In 2002, the output of solid radwastes in GNPS was 63.5 m"3, only 50% of 1995 (127 m"3), reached the advanced level as the same type NPPs in France. During the period 1994-2002, the accumulated production of solid radwaste Packages in GNPS is 1563.51 m"3 only 18% of the design value; all the packages meet the standard and requirement for safe disposal. Besides, this paper analyzes some new technical processes and presents some proposals for further decreasing the solid radwaste production
A probability-based approach is presented as the integration of probabilistic methods and deterministic modelling based on the finite element method. An existing finite element software package was linked to an existing probabilistic package to analyse the complex mechanics that occur during the transient non-linear analysis of impact problems. This methodology is applied to a pipe whip analysis of a group-distribution-header, which results from a guillotine break, and subsequent impact with the adjacent building wall; this is a postulated accident for the Ignalina Nuclear Power Plant RBMK-1500 reactors. The uncertainties of material properties, component geometry data and loads were taken into consideration. The probabilities of failure of the impacted header and of the header support-wall were estimated given uncertainties in material properties, geometrical parameters and loading. The software ProFES was used for the probabilistic analysis ...
Presently in the FRG there are essentially three institutions involved in corrosion experiments related to high level waste package materials, namely KfK-INE, Nukem and Bayer Leverkusen. In 1981 KfK-INE started a corrosion test program aiming at the selection of suitable canister materials for vitrified high level waste. The program encompassed electrochemical investigations, which were concluded in 1984. Moreover field corrosion tests and laboratory experiments were initiated, and are still ongoing. Several possible canister materials such as mild steel, Ti-Pd-alloy, Hastelloy C4 and others were investigated under the influence of varying parameters such as temperature, and radiation. Both Nukem Company and DWK were assigned the responsibility to conceive and develop a cask for the direct final disposal of spent fuel assemblies. Two solution turned out as most promising for corrosion protection of final disposal casks: (1) protective layer of Hastelloy C4 on the ...
The antimicrobial effects and quality changes of O2, He, N2 or N2O-enriched active modified atmosphere packaging -MAP- (100 kPa initial gas partial pressure) compared to a chlorinated -100 mg L-1 NaClO- passive MAP (control) in fresh-cut Red Chard baby leaves up to 8 days at 5 degreeC were studied. High O2 MAP (>85 kPa O2) inhibited natural microflora growth during 7 days at 5 degreeC. Regarding control treatment, no differences for He and N2O-enriched MAPs on microbial growth were found although control samples were previously disinfected. Initial total phenolics content (613 mg ChAE kg-1 fw) increased up to 61-93% after 6 days at 5 degreeC under O2, He, and N2-enriched MAPs. Vitamin C content decreased up to 67% after shelf life in control samples while lower decreases were monitored in ...
Energy and exergy studies were conducted in an orange juice manufacturing industry in Nigeria to determine the energy consumption pattern and methods of energy optimization in the company. An adaptation of the process analysis method of energy accounting was used to evaluate the energy requirement for each of the eight defined unit operations. The types of energy used in the manufacturing of orange juice were electrical, steam and manual with the respective proportions of 18.51%, 80.91% and 0.58% of the total energy. It was estimated that an average energy intensity of 1.12 MJ/kg was required for the manufacturing of orange juice. The most energy intensive operation was identified as the pasteurizer followed by packaging unit with energy intensities of 0.932 and 0.119 MJ/kg, respectively. The exergy analysis revealed that the pasteurizer was responsible for most of the inefficiency (over 90%) followed by packaging (6.60%). It was suggested that ...
What kind of hardware and software should be used to interface GPIB devices with the existing computer system. One idea was to use a commercially available Multibus card, BLC 8488 from National Semiconductor, whose on-board Z80 would manage the GPIB read/write functions and handshakes. With this card, one could make a hardware system which would consist of (1) CAMAC 080, (2) Multibus crate, (3) M. Shea's M68000, (4) M080, (5) BLC 8488 and (6) memory board. And the software considered for such a hardware package was GAS, which had been an established software package for communication between the ACNET computer system and smart CAMAC modules. However, a second idea was to put everything on a two-wide CAMAC module. The author pursued the second idea and came up with a two-wide CAMAC module called C488. The author describes the hardware - block diagrams, circuit blocks, front panel and hardware tests. He also refers to the software - ...
The objective of this report was to evaluate four possible alternative methods of preparing and packaging spent fuel assemblies for geologic disposal against the Reference Process of unmodified spent fuel. The four alternative processes were: (1) End fitting removal, (2) Fission gas venting and resealing, (3) Fuel bundle disassembly and close packing of fuel pins, and (4) Fuel shearing and immobilization. Systems analysis was used to develop a basis of comparison of the alternatives. Conceptual processes and facility layouts were devised for each of the alternatives, based on technology deemed feasible for the purpose. Assessments were made of 15 principal attributes from the technical, operational, safety/risk, and economic considerations related to each of the alternatives, including both the surface packaging and underground repository operations. Specific attributes of the alternative processes were evaluated by assigning a number for each ...
Summary In this study, antimicrobial activity of zein films incorporated with partially purified lysozyme and disodium ethylenediaminetetraacetic acid (Na2EDTA) has been tested on selected pathogenic bacteria and refrigerated ground beef patties. The developed films containing 700-g-cm-2 lysozyme and 300-g-cm-2 Na2EDTA showed antimicrobial activity on Listeria monocytogenes, Escherichia coli O157:H7, and Salmonella typhimurium. The application of lysozyme and Na2EDTA incorporated zein films on beef patties significantly decreased total viable counts (TVC) and total coliform counts after 5-days of storage compared to those of control patties (P-2EDTA or Na2EDTA alone significantly slowed down the oxidative changes in patties during storage (P-P-2EDTA for active packaging of refrigerated mea...
This paper describes a proposed set of guidelines for analyzing the energy savings achieved by a package of retrofits or an extensive rehabilitation of an existing home. It also describes certain field test and audit methods that can help establish accurate building system performance characteristics that are needed for a meaningful simulation of whole-house energy use. Several sets of default efficiency values have been developed for older appliances that cannot be easily tested and for which published specifications are not readily available. These proposed analysis procedures are documented more comprehensively in NREL Technical Report TP-550-38238.
In recent years, there has been increasing demand for resource-recycling of waste plastic, especially due to the introduction of legislation on recycling of materials used for packages of household goods. Methods of recycling waste plastic from household goods are currently still under development, and appropriate techniques to deal with such waste are required. Toshiba has developed a technique to dehydrochlorinate plastic containing polyvinyl chloride (PVC). This paper introduces our petrolization and dehydrochlorination system for waste plastic containing PVC. (author)
Volume VII of the documentation for the Phase I Data Analysis Task performed in support of the current Regional Flow Model, Transport Model, and Risk Assessment for the Nevada Test Site Underground Test Area Subproject contains the tritium transport model documentation. Because of the size and complexity of the model area, a considerable quantity of data was collected and analyzed in support of the modeling efforts. The data analysis task was consequently broken into eight subtasks, and descriptions of each subtask's activities are contained in one of the eight volumes that comprise the Phase I Data Analysis Documentation.
Volume VI of the documentation for the Phase I Data Analysis Task performed in support of the current Regional Flow Model, Transport Model, and Risk Assessment for the Nevada Test Site Underground Test Area Subproject contains the groundwater flow model data. Because of the size and complexity of the model area, a considerable quantity of data was collected and analyzed in support of the modeling efforts. The data analysis task was consequently broken into eight subtasks, and descriptions of each subtask's activities are contained in one of the eight volumes that comprise the Phase I Data Analysis Documentation.
Volume IV of the documentation for the Phase I Data Analysis Task performed in support of the current Regional Flow Model, Transport Model, and Risk Assessment for the Nevada Test Site Underground Test Area Subproject contains the hydrologic parameter data. Because of the size and complexity of the model area, a considerable quantity of data was collected and analyzed in support of the modeling efforts. The data analysis task was consequently broken into eight subtasks, and descriptions of each subtask's activities are contained in one of the eight volumes that comprise the Phase I Data Analysis Documentation.
Volume II of the documentation for the Phase I Data Analysis Task performed in support of the current Regional Flow Model, Transport Model, and Risk Assessment for the Nevada Test Site Underground Test Area Subproject contains the potentiometric data. Because of the size and complexity of the model area, a considerable quantity of data was collected and analyzed in support of the modeling efforts. The data analysis task was consequently broken into eight subtasks, and descriptions of each subtask's activities are contained in one of the eight volumes that comprise the Phase I Data Analysis Documentation.
In-situ sodium activated organo modified bentonite clay was also used for partial replacement of the carbon black (N330). Detailed study with the black filled compound revealed that, with slight modification of the curing package, up to 10 phr of the carbon black replacement is possible. At equivalent loading of 5 and 10 phr of in-situ sodium activated organo modified bentonite clay exhibited better properties in comparison to carbon black filled compound.
A rotational speed control, tailored to the Sunflower system requirements, was designed and fabricated in breadboard, preprototype, and prototype configurations. These units were subjected to performance and environmental testing which has led to design improvements. Program efforts have yielded hardware capable of meeting all performance requirements and of operating under all the environmental conditions to which the units were exposed. Attractive design changes were identified and, in some cases, completed. These changes involve improvements in circuitry and packaging, the primary objectives of which are to eliminate startup bias batteries and reduce weight. It is recommended that the reported program be extended to implement these improvements. (auth)
This bibliography contains citations concerning the recycling of scrap plastic produced in the injection-molding process. Plastic pellets made from scrap that are used in the injection-molding process are also discussed. Recycling equipment and automated recycling systems are described. Ways to utilize plastic scrap from used cars, packaging materials, and waste from polyurethane production are presented. (This updated bibliography contains 102 citations, 13 of which are new entries to the previous edition.)
This bibliography contains citations concerning the recycling of scrap plastic produced in the injection-molding process. Plastic pellets made from scrap that are used in the injection-molding process are also discussed. Recycling equipment and automated recycling systems are described. Ways to utilize plastic scrap from used cars, packaging materials, and waste from polyurethane production are presented. (This updated bibliography contains 116 citations, 14 of which are new entries to the previous edition.)
The bibliography contains citations concerning the recycling of scrap plastic produced in the injection molding process. Plastic pellets made from scrap, that are used in the injection molding process, are also discussed. Recycling equipment and automated recycling systems are described. The reuse of plastic scrap culled from junk automobiles and packaging materials is discussed, and waste byproducts from polyurethane production are described. (Contains a minimum of 80 citations and includes a subject term index and title list.)
The bibliography contains citations concerning the recycling of scrap plastic produced in the injection molding process. Plastic pellets made from scrap, that are used in the injection molding process, are also discussed. Recycling equipment and automated recycling systems are described. The reuse of plastic scrap culled from junk automobiles and packaging materials is discussed, and waste byproducts from polyurethane production are described. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)
This paper describes the problems and capabilities of highly enriched actinide isotopes production by electromagnetic separation in the S-2 mass separator of VNIIEF. Isotope enrichment characteristics for uranium, plutonium, americium and curium isotopes, used in different nuclear physics experiments, and isotope contamination for single and double separations are presented. The capabilities for highly enriched "2"4"4Pu and "2"4"8Cm production for nuclear accelerator experiments and other applications are described, some details of the current and future programmes are given and the transport packaging is described. (orig.).
The paper presents the integration of the SIMBAD space charge module in the UAL framework. SIMBAD is a Particle-in-Cell (PIC) code. Its 3-D Parallel approach features an optimized load balancing scheme based on a genetic algorithm. The UAL framework enhances the SIMBAD standalone version with the interactive ROOT-based analysis environment and an open catalog of accelerator algorithms. The composite package addresses complex high intensity beam dynamics and has been developed as part of the FAIR SIS 100 project.
... We strive to meet the needs of our members at as low a cost as possible. Visit website eSight Energy eSight Energy ...eSight® is the most advanced fully web enabled energy monitoring and targeting package on the market. This comprehensive and intuitive energy management suite ...Drinks Company We have developed the worlds most environmentally friendly cold drinks vending system. Over 40 different drinks available which are good for ...EcoSort® recycling system has been designed to offer customers a unique and flexible solution for the source separation of waste materials. Visit website ...
Contract No. DACA 90-8l-C-oo72 directs that a basewide energy study be accomplished for the Mannheim and Pirmasens Military Communities, Federal Republic of Germany. The project is identified as Energy Engineering Analysis Program (EEAP) Package No. 5. The overall objective of the study is to produce a systematic plan of improvement projects that will reduce by 1985 the energy consumption in compliance with the Army Facilities Energy Plan without decreasing the readiness posture of the Army.
There is a general concern with insiders smuggling bomb quantities of explosives into sensitive facilities such as nuclear facilities. At this time, there is no single explosives detection device that is suitable for monitoring personnel and their packages for explosives in an operational facility environment. However, there are techniques combining available commercial technologies with procedures and threat analysis that can significantly increase the insiders risk and reduce the population of adversaries. This paper describes the available applicable explosives detection technologies and discusses the techniques that could be implemented on an interim basis. It is important that these techniques be considered, so that some interim level of security against the explosives threat can be established until more sophisticated equipment that is under development becomes available.
Two aspects of the chromatin repeat length (r_l) are discussed: (i) Why is r_l longer for slowly dividing cells than in rapidly dividing cells?, and (ii) Why is the temporal evolution of r_l a decreasing function of time (t) in mammalian cortical neurons whereas it is an increasing function of t for granule cells around the time of birth? These questions are discussed in terms of a hypothesis which assumes a correlation between deoxyribonucleic acid (DNA) packaging, transcription, and replication. (author). 27 refs.
Pittston Coal Company recognized the potential economic benefit of improving process efficiency with increased capacity at it`s U.K. No. 1 Coal Preparation Plant. Accordingly, extensive research, both domestically and internationally, was conducted to select the appropriate technologies to achieve the desired circuit in the most cost effective manner while, at the same time, sacrificing neither structural integrity nor process performance. Large diameter heavy media cyclone technology was combined with highly efficient banana type screens and improved high intensity magnetic separators to create a coordinated process circuit that provided high efficiency at very high capacities in an economically attractive package.
Aluminum electrolytic capacitors are presently not allowed on NASA missions because they outgas water and organic vapors, as well as H2. As a consequence, much larger and heavier packages of tantalum capacitors are used. A hermetically sealed aluminum capacitor has been developed under NASA-MSFC SBIR contracts. This capacitor contains a nongassing electrolyte that was developed for this application so internal pressure would remain low. Capacitors rated at 250 to 540 V have been operated under full load for thousands of hours at 85 and 105 C with good electrical performance and low internal pressure. Electrolyte chemistry and seal engineering concepts will be discussed.
The Rosebel gold district is hosted in a Paleoproterozoic greenstone belt of the Guiana Shield and has many characteristics that enable classification of the ores as an orogenic gold deposit. Host rocks have undergone several phases of deformation. However, gold deposition occurred late in the structural history of the belt, and is considered part of a late regional metallogenic event with respect to the geotectonic evolution of the Guiana Shield. Economic gold mineralization is hosted in felsic to mafic volcanic rocks and two sedimentary successions that are differentiated into turbiditic and arenitic depositional packages. The detailed lithostratigraphic characterization and the geochemistry enable the correlation of the local rock types with the Paramaka, the Armina, and the Rosebel for...
17 papers are presented. Topics covered include: the POG system - a new concept in the use of ANFO; demolition of a motorway bridge; presplit and smooth blasting; VIBReX - a predictive code for assessing the effect of blast design on ground vibration; ground vibrations from blasting; digital seismographs; human response to blasting and the effects on planning conditions; landform construction by restoration blasting; use of small diameter explosives; efficient priming; safety management in the explosives industry; and the law on packaging of explosives. Two papers have been abstracted separately.
Source-term codes to predict the release of radionuclides from nuclear waste packages have been developed and implemented worldwide. A survey and initial comparison of the attributes and capabilities of 13 international source-term codes was recently completed. This preliminary analysis focused on comparison of transport factors/processes and solution methods. This initial comparison is a necessary first step in a properly-conceived, systematic benchmarking of source-term codes. Advantages of such a comparison include assurance of the mathematical correctness of implemented models, comparison and quantification of variances introduced by different types of simplifications, and identification and quantification of the impact of near-field processes.
The foils of various materials were irradiated with "6"0Co with an activity of 11,538 TBq. The minimum radiation dose was 25 kGy. Changes in chemico-physical properties were evaluated by infrared spectroscopy and were not detected after irradiation with 25 kGy. Packing foils were subjected to the following tests: mechanical tests, tests of weld strength, tests of impact resistance, free fall tests, permeability tests for water vapour and microbiological tests. The results of all tests were tabulated. The tests showed that the foils are impermeable for microorganisms and provided the welds are airtight the packed products remain sterile. (J.P.).
The demand for energy management in teaching packages of Higher Vocational schools in the Netherlands and the possibilities to implement energy management into the different sectors of this school type have been investigated. The results are based on interviews with representative of the above-mentioned school types. Recommendations are made for a follow-up of this investigation in order to set up an energy management teaching module. 1 tab., 1 appendix
Aluminum hydroxide coatings on fuel elements stored in aluminum canisters in K West Basin were measured in July and August 1998. Good quality data was produced that enabled statistical analysis to determine a bounding value for aluminum hydroxide at a 99% confidence level. The updated bounding value is 10.6 kg per Multi-Canister Overpack (MCO), compared to the previously estimated bounding value of 8 kg/MCO. Thermal analysis using the updated bounding value, shows that the MCO generates oxygen concentrate that are below the lower flammability limits during the 40-year interim storage period and are, therefore, acceptable.
Complex abdominal lesions include a variety of pathologies, such as septated, infected, and hemorrhagic cysts, abscesses, tumors, and fluid collections of different ethiology. These lesions present diagnostic difficulties with both Ultrasonography (US) and Computed Tomography (CT), since findings may not be present or, when present, are not specific. Keeping these limitations in mind, we evaluated 105 patients (111 abdominal lesions) with both US and CT in order to compare their adequacy in predicting the nature of the lesion. On the basis of US and CT results, complex abdominal lesions were divided in four classes: class I includes 43 cases in which both examinations gave the same contribution to the definition of the nature of the lesion, class II (14 lesions, mainly sperimentated cysts), in which US was superior to CT, class III includes 45 cases of hemorrhagic cysts, abscesses, fluid collections and, less frequently, cystic tumors; class IV includes 9 cases in ...
Tridimensional localization of bone and soft tissue injuries in complex facial trauma is fundamental for treatment. The face can be conceptualized as 3 groups of interconnected osseous struts that are oriented in the horizontal, sagittal and coronal planes. Each group of struts is closely related to specific soft tissue structures that are susceptible to injury. Any single CT section in the coronal plane or in the axial plane contains parts of one or more these struts. Facial CT in biplane were performed in 32 patients of facial trauma. The most common site of facial fractures is found in middle part of horizontal struts, geometrically in anteromedial portion of the inferior orbital fissure of the face. The most common soft tissue injury combined with facial fracture is hematoma and/or herniated orbital contents into the maxillary sinus. The serious combined soft tissue injuries were ocular rupture, retroorbital hematoma and optic nerve injury resulting blindness. CT was superior to ...
Malignant tumors of the sinonasal cavities are rare and often diagnosed late in the course of the disease. These tumors can extend into regions such as the orbit and brain, where treatment is difficult. Ten patients with non treated sinonasal malignant neoplasms and radiological evidence of tumor extension into the orbit and brain were studied with computed tomography. Five (50%) tumors were epithelial neoplasms whereas squamous cell carcinoma was the most common type (3 cases). The ethmoidal sinus was the most common site of origin of the tumors (40%), followed by the maxillary sinus (30%) and nasal cavity (30%). A total of 16 orbits were involved since 6 patients (60%) had bilateral orbital involvement. The tumors extended more often into the orbits through erosion of the medial and inferior orbital bones. All orbital compartments were involved in the majority of the orbits. Tumoral extension into the cranial cavity was more common through the ethmoidal (70%) and ...
The introduction of positron emission tomography (PET)/magnetic resonance (MR) systems into medical practice in the foreseeable future may not only lead to a gain in clinical diagnosis compared to PET/computed tomography (CT) imaging due to the superior soft-tissue contrast of the MR technology but can also substantially reduce exposure of patients to ionizing radiation. On the other hand, there are also risks and health effects associated with the use of diagnostic MR devices that have to be considered carefully. This review article summarizes biophysical and biological aspects, which are of relevance for the assessment of health effects related to the exposure of patients to both ionizing radiation in PET and magnetic and electromagnetic fields in MR. On this basis, some considerations concerning the justification and optimization of PET/MR examinations are presented - as far as this is possible at this very early stage. Current safety ...
The seismic reflection exploration technique which is one of the geophysical methods for oil exploration became effectively to image the subsurface structure with rapid development of computer. As a tool to perform seismic inversion, seismic forward modeling program using ray tracing should be developed. In this study, we have developed the algorithm that is to calculate the travel time of the complex geological structure using ray tracing by subdividing the geologic model into triangular element (finite element) having the constant velocity. We can analytically calculate Jacobian with some information by this current ray tracing. With this Jacobian, we will develop new algorithm which is to obtain geological properties and to image the subsurface. Since the FEM (Finite Element Method) ray tracing we have developed goes well the inverse velocities structure, we can apply the inversion problem to complex geological model. This report consists of 3 articles. 1) Development of 2-D ...
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray CT technique. (orig.).
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray CT technique. (orig.).
The production of radiopharmaceuticals used in positron emission tomography (PET) can require large amounts of activity at the start of synthesis in order to yield sufficient labeled material for clinical studies. Several investigators have developed remote and automated systems for the routine production of PET radiopharmaceuticals in order to reduce radiation exposure to personnel. Such devices, however, suffer from limited flexibility and can be relatively complicated in design. These systems are also limited to the production of a single or a few closely related compounds. Furthermore, changes in chemistry would require considerable modifications in hardware and/or software in order to bring the device back into operation. To circumvent the above limitations associated with the remote production of PET radiopharmaceuticals, the authors have investigated the use of laboratory robotics as a flexible alternative to the synthesis of several short-lived ...
In order to improve the image quality of linear tomography performed with the Fuji Computed Radiography (FCR) system, we have examined one-dimensional unsharp mask filtering to reduce blur formed in the direction of tomographic swing. We determined a mask size and a weighting factor of the image processing suitable to obtain a quality tomogram. The mask size of 41 x 1 pixels for a 14 x 14'' imaging plate, which modifies the original image date and results in demonstrating a peak frequency at 0.2 cycles/mm for spatial frequency spectrum, is superior in showing fine vessel structures and morphological features of pathology in the lung fields. An additional spatial frequency filtration in the direction perpendicular to the tomographic movement reduces the blur and clearly demonstrates object contours running parallel to the tube movement. However, the additional filtration increases the appearance of noise on the processed image and offsets the ...
Correct ortopedic therapy for traumas of the cervical rachis requires perfect knowledge of the spatial balance of the fracture focus. The authors belive Computed Tomography (CT) to be the most suitable, and often indispensable, method for this purpose. Twenty-four patients were examined for traumatic pathology of the cervical rachis. In 7 cases with clinically minor traumas, the negative outcome of the traditional traumas, the negative outcome of the traditional exam was considered reliable and sufficient for therapeutic purposes. The extant 17 patients were examined also by means of CT, either to better dermine the characteristics of skeletal lesions already ascertained with traditional techniques or to asses the presence of clinically-suspected osteo-articular lesions, even with negative conventional X-rays. For 9 of these patients orthopedic treatment was considered sufficient, whereas 8 patients underwent surgery and were subsequently examined with CT, which ...
Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T_1-weighted scans the tumors ...
To analyze and review the most common focal lesions of the external auditory canal (EAC), describing the computed tomography (CT) findings. The CT images of EAC were reviewed in a series of 167 patients. Abnormal findings were recorded in 13 cases. The CT images were correlated with otoscopic and/or intraoperative findings. There were four cases of osteoma (one located outside the EAC); all of which were treated surgically, as was the one case of exostosis. Six patients presented debris in EAC, coinciding with clinical evidence of external otitis. There were two cholesteatomas derived from EAC, one of them secondary to survery to treat osteoma. On patient was diagnosed as having a basal cell carcinoma of the ear, extending to EAC, but refused to undergo surgery. Five patients presented small triangular laminae of dense bone arising from the upper wall of the EAC which were defined as abnormal variants of the fusion of the temporal squamous epithelium to the ...
Ionizing radiation is a standard treatment for various human solid tumors. However, several clinical studies showed that a significant proportion of patients undergoing radiotherapy for hepatocellular carcinoma (HCC) develop intrahepatic and extrahepatic metastasis. Understanding of radiation-induced cancer cell invasiveness and behavior is essential and of great important for developing suitable treatment strategies to contain cancer spread. Therefore, in this study we evaluated the effectiveness of using swept source optical coherence tomography (SS-OCT) to monitor the enhancement of HCC cell invasiveness by radiation. SS-OCT images were acquired and recorded to obtain three-dimensional data sets per four hours in 48 hours after irradiating HepG2 cells with 7.5 Gy. The cell migration behavior in three-dimensional tissue models was quantified from images of radiation-induced and sham-irradiated cells.
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the reconstructed image. The image quality could be satisfactory to distinguish acrylic ...
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the reconstructed image. The image quality could be satisfactory to distinguish acrylic ...
Introduction: There are many problems in the radiological diagnosis of aseptic loosening in total hip arthroplasty. Computed tomography (CT) and magnetic resonance tomography (MRT) are not usable for metallic implants (stainless steel, cobalt alloy, titanium alloy). Material and Methods: From April 1993 to December 1993 15 CFRP non-cemented hip prostheses have been implanted. In a prospective clinical study plane radiographs, CT and MRT have been analysed. Results: Three stems were revised (1 femoral fracture, 1 severe thigh pain, 1 aseptic loosening). CFRP are not visible in plane radiographs. There was a complete (two-third of the cases) or nearly complete (one-third of the cases) small sclerotic interface between the prosthesis and the bone, these were apparent in CT and MRT in stable implant cases and did not have any clinical correlations. Discussion: The small sclerotic interface is quite different in comparison to so called 'Reactive ...
Purpose: To evaluate the diagnostic performance (colorectal lesions) of computed tomography (CT) colonography in 111 patients, a majority of whom were at high risk for colorectal neoplasia. Material and Methods: After bowel preparation, CT colonography was performed, immediately followed by conventional colonoscopy. The diagnostic performance of CT colonography was analyzed relative to lesion size, histological diagnosis, and diagnostic certainty. Results: The sensitivity of CT colonography increased with lesion size (P<0.001), and was 91% (21/23) for lesions > or = 10 mm. All 10 carcinomas and 86% (19/22) of adenomas > or = 5 mm were detected. Unconfirmed or false-positive CT findings were generally small and/or reported with low diagnostic certainty. The specificity of CT colonography would be 45% (30/66; 95% CI 34% to 57%) if patients with findings of any size and any diagnostic certainty were selected for follow-up, and 92% (85/92; 95% CI ...
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,{theta}) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,#theta#) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.
The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Bjoerk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic valve replacements, two redo mitral replacements and one Amplatzer ductal occluder occlusion of a ...
Cerebral angiography, pneumoencephalography, and radioisotope brain scan with their differing diagnostic abilities have provided the neurologist and neurosurgeon with extremely valuable diagnostic techniques. It is doubtful, however, if any of these now conventional methods had the enormous impact on the practice of neurology that computer assisted axial tomography (C.A.T.) is beginning to have. Here, for the first time, is a test which, without significant risk or discomfort, can demonstrate some normal intracranial (and intraorbital) structures, can demonstrate some normal intracranial pathology and, in many cases, can make the potentially dangerous contrast studies unnecessary. After only a few months experience with C.A.T. in a clinical setting, it has become obvious that there will have to be a reappraisal of the accepted investigative work-up of many conditions. While it is too early to have formulated strict criteria for the use of C.A.T., this paper is an ...
Forty-one cases of mediastinal tumor examined by computed tomography were reviewed. CT findings of the mediastinal malignancy were as follows: 1) inhomogeneous density on contrast CT, 2) equivocaton of fat plane surrounding the tumor, 3) irregular margin. Benign teratoma had smooth margin and included fat or calcification density. Mediastinal seminoma was observed as a lobulated mass with no calcification on CT. These findings were similar to the patterns of malignant thymoma or lymphoma. Consequently, it was very difficult to differentiate between malignant thymoma and malignant lymphoma by CT. According to our data, malignant thymoma tended to expand to only one side of the anterior mediastinum and to invade the anterior chest wall. On the other hand, malignant lymphoma of anterior medistinal type expanded into the trachea and the superior vena cava. In patients with sarcoidosis, the enlargement of bilateral hilar lymph nodes was commonly observed, on the ...
As yet, the role of Computed Tomography (CT) as a routine imaging technique in the staging and follow-up of thoracic Hodgkin's disease has not been assessed. The authors reported the results obtained in 120 patients affected with thoracic Hodgkin's disease, staged and followed by means af chest X-rays and CT. CT better identified intrathoracic involvement of mediastinal nodes, of lung parenchyma, of pleura, and of pericarcial and chest walls in 54/120 patients (45%), with staging modifications in 18 (15%) of them only. Treatment was changed only in 12 patients (19%) where radiation therapy had been planned. The clinical value of the additional information yielded by CT was especially evident in the follow-up: CT allowed the correct evaluation of persistent/ recurrent disease in 51/117 patients (43.5%), a figure high enough to suggest the use of CT in the routive follow-up of patients affected with thoracic Hodgkin's disease.
Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localization of abnormalities. The resulting correlation of the anatomical and functional images may clarify the nature of the abnormality and help diagnose or stage the underlying disease. Whereas successful image fusion software has been developed for the brain, only limited success has been achieved for image alignment in other parts of the body. The development and current status of alternative approaches are presented. Dual-modality imaging is described with devices where two modalities are combined and mounted in a single gantry. The use of existing scanner technology ensures that no compromises are made in the clinical efficacy of either the anatomical or functional imaging ...
The aim of this study was to assess the body weight-tailored contrast material injection protocol for 64-detector computed tomography (CT) to maintain optimal coronary CT attenuation. A total of 60 patients who underwent CT coronary angiography were assigned to one of three groups: protocol A, total of 0.7 ml kg"-"1 with 300 mg I/ml iodine concentration; protocol B, total of 0.6 ml kg"-"1 with 350 mg I/ml; protocol C, total of 0.7 ml kg"-"1 with 350 mg I/ml. The injection duration was 10 s in all patients. The proportion of intracoronary attenuation values >325 Hounsfield unit (HU) was compared on a per-vessel and per-patient basis. The attenuation value was significantly more likely to exceed 325 HU with protocol C (95% for reader 1 and 90% for reader 2) than with protocol A or B on the per-vessel analysis (P325 HU) with 64-detector CT when using an injection duration of 10 s. (author)
While there have been many experimental and calculational investigations on absorbed dose distribution in the patient resulting from conventional X-ray procedures, such data for computerized tomography (CT) are still sparse. As this diagnostic procedure has shown a rapid increase in application during recent years, we have determined absorbed dose to body organs in a human phantom resulting from CT examinations. The exposure model consists of the heterogeneous MIRD-5 phantom and a suitable Monte-Carlo method to calculate absorbed dose to organs of interest. The exposure conditions are specified according to the exposure specifications of a CT-scanner currently in use. The calculations cover the range of body tissues of interest in terms of organ absorbed doses as well as a risk weighted absorbed dose. A detailed example showing the calculation of red bone marrow dose is given and a somatic effective dose equivalent Hsub(ES) is calculated for different conventional ...
In cases of obstructive colorectal cancer (CRC), preoperative diagnosis of the proximal lesion is often difficult when the primary lesion impedes the passage of the endoscope. The aim of this study was to evaluate the usefulness of fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) in such cases. A total of 52 obstructive CRC patients who underwent preoperative FDG-PET and subsequent surgical resection were retrospectively reviewed. The correlation between characteristics of the proximal lesion and FDG-PET findings was analyzed statistically. There was a significant correlation between the proximal lesion size and the maximum standardized uptake value (P=0.00016). Abnormal FDG accumulation in the proximal colon indicated the existence of proximal cancer or adenoma with a sensitivity of 50% and a specificity of 100%. There was a significant difference in the distribution of tumor size between the cases with proximal abnormal accumulation and those ...
Integration of positron emission tomography (PET) and magnetic resonance (MR) has become a topic of increasing interest to the imaging community over the past two years. In this text, the authors attempt to distinguish facts from fiction concerning such integrated systems. Analysis of existing information of combined imaging on existing brain PET/MR systems and imaging experience with PET-computed tomography (CT) is reviewed. Various types of system integration of PET and MR are discussed with completely independent systems on one hand and completely integrated systems with the possibility of simultaneous data acquisition on the other hand. Furthermore, it is discussed, what simultaneous data acquisition with nuclear imaging systems combined with MR or CT really means, as technical simultaneity may not be relevant in light of the pharmacokinetics of the nuclear tracers used. The authors conclude that combining PET/MR is an interesting research ...
Thermal models are constructed and analyses are performed of aluminum-based spent nuclear fuel (Al-SNF) in interim dry storage and geologic disposal configurations. Two models are developed, referred to as the interim storage model and the codisposal waste package (WP) model. Time-dependent source terms of Al-SNF forms and the defense high-level waste (DHLW) canisters are also developed for thermal performance analysis of the geologic codisposal WP.The interim storage model is a three-dimensional conduction-convection conjugate model to investigate the natural convection cooling of a sealed dry storage canister with vertical orientation in a dry storage vault. The analysis is made for various decay heat sources (equivalent to 25 to 35 kW/m{sup 3}) using various boundary conditions around the canister wall and with backfilled nitrogen or helium gas. Based on the data obtained from the Savannah River Site experimental work and available from the literature, an ...
The resistance of several packaging materials to penetration by 4 species of rice insect pests was determined. Five insects of adult or larval stage were confined in pouches made from 9 different packaging materials with or without irradiated rice. It was observed that both adults and larvae of species Tribolium castaneum Herbst., Sitophilus zeamais L., Oryzaephilus surinamensis L. and Cocyra cephalonica Stainton, were incapable of penetrating pouches made from white polyvinychloride of 0.175mm thickness, low density polyethylene of 0.130mm thickness and 0.150mm thick low density polyethylene. However, penetrations marks were found in pouches made from hard paper with a thickness of 0.155mm, clear polivinylchloride of 0.130mm thickness, low density polyethylene of 0.085mm thickness, low density polyethylene 0.100mm thick, high density polyethylene of 0.06mm thickness and 0.080mm thick polypropylene. Tribolium castaneum could be considered as a ...
This paper reports about in-situ corrosion studies on selected materials for long-term resistant high-level waste (HLW) packagings acting as a barrier in a rock salt repository. The materials (Ti 99.8-Pd, Hastelloy C4 and five iron-base materials) were investigated in heated boreholes in the Asse salt mine under simulated HLW disposal conditions prevailing in normal operation of repository and in certain accident scenarios. The experiments under normal operating conditions were performed at temperatures of 120 deg. C to 210 deg. C (vertical temperature profile in the boreholes) without and with gamma irradiation (3#centre dot#10"2 Gy/h, Co-60 source) within the framework of the German/US Brine Migration Test. In these experiments only small amounts of migrated brine inclusions (NaCl-rich) from the rock salt were present as corrosion medium. In the experiments carried out under simulated accident conditions with intrusion of larger amounts of NaCl brine into the HLW ...
The US Department of Energy (DOE) is preparing to perform significant remediation activities of the sites for which it is responsible. To accomplish this, it is preparing a corporate global plan focused on activities over the next decade. Significant in these planned activities is the transportation of the waste arising from the remediation. The costs of this transportation are expected to be large. To support the initial assessment of the plan, a cost estimating model was developed, peer-reviewed against other available packaging and transportation cost data, and applied to a significant number of shipping campaigns of radioactive waste. This cost estimating model, known as the Ten-year Plan Transportation Cost Model (TEPTRAM), can be used to model radioactive material shipments between DOE sites or from DOE sites to non-DOE destinations. The model considers the costs for (a) recovering and processing of the wastes, (b)packaging the wastes for ...
Los Alamos National Laboratory (LANL) is a unique facility covering over 43 square miles. The Emergency Management and Response Office (EM&R) is required to respond, provide Incident Command (IC), and coordination for all Laboratory emergencies. This requires IC`s and support staff to respond to the actual scene of the incident. Since the IC is under numerous constraints and stress, the office wanted the capability of locating the EM&R vehicles on an electronic map. An automated vehicle location (AVL) system was required for the additional safety of the emergency response personal. The requirements for the AVL system include total automatic tracking and low cost. After careful consideration, it was determined that the most efficient and cost effective system would be based on packet radio technology as the transmission media. The location is determined by the Department of Defense Global Positioning System (GPS). The system that was designed and constructed required four ...
The paper introduces the disposal procedures of the old reactor pressure vessel head. Reactor pressure vessel (RPV) heads were replaced successfully in Daya Bay Nuclear Power Plant. The on-site treatment and disposal of replaced heads was thereafter implemented. This is the first time in China for large size radioactive article disposal. To guarantee the safety of old head treatment, issues of radiation protection have to be taken into account. Dose rate distribution of the old head surface and radioactivity were initially calculated according to the operation history and the neutron flux rate of the reactor. Shielding calculation and package design was thereafter worked out based on the data obtained from the old head, e.g. neutron flux, sorts of nuclides, radioactivity and dose rates. Shielding package was afterwards manufactured in special factories and transported to Daya Bay NPP site by truck and ship. The shielding ...
The purpose of this Analysis and Model Report (AMR) supporting the Site Recommendation/License Application (SR/LA) for the Yucca Mountain Project is the development of elementary analyses of the interactions of a hypothetical dike with a repository drift (i.e., tunnel) and with the drift contents at the potential Yucca Mountain repository. This effort is intended to support the analysis of disruptive events for Total System Performance Assessment (TSPA). This AMR supports the Process Model Report (PMR) on disruptive events (CRWMS M&O 2000a). This purpose is documented in the development plan (DP) ''Coordinate Modeling of Dike Propagation Near Drifts Consequences for TSPA-SR/LA'' (CRWMS M&O 2000b). Evaluation of that Development Plan and the work to be conducted to prepare Interim Change Notice (ICN) 1 of this report, which now includes the design option of ''Open'' drifts, indicated that no revision ...
In order to qualify corrosion resistant materials for high level waste (HLW) packagings acting as a long-term barrier in a rock salt repository, the corrosion behaviour of the preselected materials Ti 99.8-Pd, Hastelloy C4 and two unalloyed steels was investigated. The resistance of the materials to general corrosion, local corrosion and stress corrosion cracking was examined under postulated accident conditions in the repository by long-term immersion tests of up to 4 years duration and electrochemical methods. The parameters investigated were different salt brines, temperatures of 90 deg. C, 170 deg. C and 200 deg. C as well as a gamma radiation field of 10"3Gy/h (10"5rad/h). Among the materials studied, Ti 99.8-Pd exhibited the highest corrosion resistance. This material corroded at a very low rate (
Twenty-five patients with ovarian carcinoma who had been operated and treated with chemotherapy underwent clinical examination and CT before reintervention (second-look laparotomy) to detect the presence of eventual recurrences. The prediction of recurrence based on CT and clinical findings was compared with the surgical findings at reintervention. CT proved to be more accurate than clinical examination in detecting recurrences; this was especially true for masses in the abdominal cavity, with the exception of small peritoneal nodules. The authors suggest the use of CT for staging the patients candidate to reintervention. This might help to avoid reintervantion in patients with persistent disease and to plan treatment.
Single photon tomography using lipophilic tracers provides tomographic representations of regional blood flow. To penetrate a healthy blood-brain barrier requires that radiotracers either are fat-soluble or have an affinity for one of the selective blood-brain barrier transport systems. In recent years there has been an increasing interest to explore the ideal physical characteristics of "9"9"mTc for diagnostic problems of brain diseases. The development of radiopharmaceuticals for brain imaging including the intensively studied "9"9"mTc-propyleneamineoxime derivatives is discussed. (author).
The aortovenous fistulas are rare, most of them are aortocaval fistula. The non-caval communication of the fistula is sparse. Herein we report a 47-year-old female diagnosed as traumatic aorto-superior mesenteric vein (Ao-SMV) fistula. The abdominal pain, fullness, and frank bruit on abdominal auscultation suggested the diagnosis of an intra-abdominal arteriovenous fistula. The diagnosis of Ao-SMV was further confirmed by the computed tomography (CT) and aortography. The fistula was successfully treated with transcatheter coil embolization. This is the first case of Ao-SMV fistula. It provides an alternative option of treatment other than conventional surgery. PMID:19327940
As a consequence of the expanded use of long term hemodialysis and continuous ambulatory peritoneal dialysis (CAPD) treatments and extended life spans, complications of end-stage renal disease and dialysis treatments are being encountered with increasing frequency in these patients. Computed tomography can accurately depict many of the potential complications of end-stage renal disease on dialysis. This article presents the abdominal CT findings of 429 end-stage renal disease patients who are on either hemodialysis or continuous ambulatory peritoneal dialysis treatment.
The US study of the posterior compartment of the knee usually allows the clinical suspicion of popliteal cyst to be confirmed. Neverthless, in case of giant Baker's cysts - which are, at any rate, less frequent -US diagnosis is more difficult. CT can help determine the benign nature of the lesion, and hallow an accurate spatial evaluation. Moreover CT, when accurately performed, demonstrates the caudal or cranial cystic spread, together with its clear separation from adjacent muscular tissues. Direct coronal scans are more useful to obtain better spatial definition than reformatted images.
To evaluate the role of positron emission tomography-computed tomography (PET-CT) in staging and determining early treatment response to chemotherapy in children with neuroblastoma (NB) and its correlation with the final outcome. Patients and Methods: Seventeen patients of NB with mean age of 51.5 months (age range 2-132 months; 14 males, 3 females) underwent serial "1"8F-fluorodeoxyglucose (FDG) PET-CT imaging. All 17 patients were for staging before any treatment. Twelve of 17 patients underwent "1"3"1I meta-iodobezylguanidine (MIBG) scan and bone scan. MIBG uptake was seen in the primary lesion in 11/12 patients. MIBG uptake in bones was seen in 3/12 patients. All bone lesions were concordant on MIBG and bone scan. Early response to chemotherapy was evaluated after two cycles using PET-CT. A 30% reduction in longest diameter was taken as cut-off value for response on CT based on the response evaluation criteria in solid tumors criteria. ...
Roentgenological analysis of the anterior chest wall was performed in twenty six patients with sternocostoclavicular hyperostosis. Initial hyperostotic change was seen at the first costosternal junction with ventral protrusion. Hyperostosis gradually developed around the first ribs, and irregular hyperostotic changes were also seen along the costoclavicular ligaments. Even in the final stage, however, sternoclavicular joint spaces were well preserved. These findings suggest that sternocostoclavicular hyperostosis is a disorder initiated around the costal cartilage including the periosteum and perichondrium, and that arthritis is not a condition stemming from that disorder.
The activities and results of a Small Business Innovation Research Phase II project entitled ''Rapid Tools for Joint Inversion and Imaging'' are presented. Research and development on three-dimensional methods to recover distributions of material property values from sparse data are reported. Innovations using artificial neural networks and extended Kalman filtering are described. The report also covers investigations on upscaling and downscaling, segmentation for data processing, and applications to ground penetrating radar and geohydraulic tomography.
The results of the examination of 23 children with Ewing's sarcoma of the rib were analyzed: panoramic chest X-rays in 4 projections, spot radiographs of the robs, superexposed pictures, laterograms, urography, angiography, computerized tomography, and scanning of the skeleton. Causes of diagnostic errors made at the first consultation by a physician, were identified. Peculiarities of X-ray signs of tumors of this site in children were studied. Diagnostic difficulties in tumors complicated by pleurisy and in tumors of small sizes with extrapleural growth were shown. Inclusions in the extraoseous tumor component were noted in 8.7% of the cases.
To improve the detection rate of lung cancer, we have introduced low-dose CT and CR technique into a population-based annual mass screening. From December 1999, 3868 and 12618 individuals participated in this screening program with CT and with CR, respectively. Primary lung cancer was detected in 15 (0.39%) by CT and 8 (0.06%) by CR. This results show high detection rate of primary lung cancer as had been previously reported. (author)
Radiological findings of chest and abdominal wall involvement in Hodgkin's disease are reported. This manifestation was diagnosed in one patient in the primary staging and in two patients during the course of the disease. Typical radiological findings are soft tissue masses in the chest and abdominal wall, in two cases with continous tumor growth of enlarged mediastinal lymphnodes into the anterior chest wall. The axial computed tomography is the best method to evaluate the extent of chest and abdominal wall involvement in Hodgkin's disease.
Single photon emission computed tomography (SPECT) of lung perfusions permits to map functioning lung parenchyma with higher sensitivity than CT. Delivering higher radiations doses it used to increase local control in lung carcinoma; this strategy is based on radiobiological and clinical studies. Lung parenchyma is a dose-limiting tissue in patients irradiated for lung cancer. Functional mapping based on SPECT and CT findings permits to design radiation beams such as to minimize irradiation of functioning lung.
An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.
The paper investigates the yield and the role of the computerized tomography in diagnosing abdominal gunshot wounds, with their rich and varied radiological signs and associated injuries, and subsequently used in the diagnosis. [Italian] Scopo del lavoro e' riportare l'esperienza personale nell'uso della tomografia computerizzata per riconoscere le lesioni da arma da fuoco dell'addome e nelle fasi successive dell'approfondimento diagnostico.
A neutron collimator system is being designed as part of a neutron imaging facility for computed tomography and real-time neutron radiography research at the through beam port of the University of Texas TRIGA reactor. Lack of sufficient information about collimator systems in a through port from the literature necessitated the use of Monte Carlo calculations using the MCNP code 3 to search for optimal design configuration and materials that maximize the thermal neutron intensity at the image plane while minimizing the fast neutrons and gamma radiation.
Three cases of primitive suprasellar germinomas are reported: the tumors show typical clinical signs (diabetes insipidus, disfunctions), but CT findings are not so specific. It is very important to reach a correct diagnosis based on clinical and radiological findings, because of very high radiosensibility of the tumor. The accuracy of preoparative diagnosis has been enhanced by CT in addition to conventional neuroradiological examinations. Due to the possible risk of meningeal spreading following biopsy, some authors prefer to avoid biopsy and to treat directly the patient by radiotherapy; a rapid reduction of the tumor size at the dose of 30 Gy suggest a possible germinoma.
Dilatation of the azygos vein is usually due to increased pressure or flow, rarely is it diopathic. Another cause is so-called continuation of the azygos in cases of absence of the hepatic segment of the inferior vena cava. The method of choice for the investigation of azygos dilatation nowadays is computer tomotgraphy. Anomalies of the inferior vena cava can be recognised in this way unequivocally by a non-invasive method. Computer tomography frequently shows important additional abnormalities (e.g. situs inversus, polysplenia), since it demonstrates all organs situated in the plane of section. (orig.).
Twenty rheumatoid arthritis (RA) patients with involvement of the cranio-cervical junction (CCJ) were given CT scan. In most cases the myelo-CT technique with the lumbar injection of small quantities of non-ionic contrast medium was adopted; CT easily diagnosed the horizontal and vertical dislocations on the CCJ, the bone strcture lesions and the inflammatory masses. A high frequency of medullary compressions was also found in these patients. Myelo-CT appears to be the technique of choice for the precise definition of the various factors responsible for the neurological complications found in RA of the CCJ.
During the last decade there was a growing interest on the application of Positron Emission Tomography, PET, techniques to Breast Imaging. More recently, preliminary results suggested the use of dedicated devices to Breast Imaging using the same technique, the so-called Positron Emission Mammography cameras, PEM. In this article we review the arguments leading to a dedicated instrument. Based on these arguments we describe the concept of a PEM camera under development within the Crystal Clear Collaboration and the first results of its expected performance in terms of sensitivity and position resolution.
A 37-year-old military mechanic presented to our institution with a chronic history of a slowly enlarging left elbow antecubital fossa mass. There was no history of other chronic illness or trauma. Magnetic resonance imaging (MRI) and excisional biopsy revealed fatty villi and synovial inflammation within the left bicipitoradial bursa, consistent with lipoma arborescens. Four years later the patient presented with a 6-month history of swelling at the antecubital fossa of the opposite elbow. Diagnostic computed tomography and MRI examinations were performed. The surgical and pathologic findings confirmed the imaging diagnosis of lipoma arborescens at the right bicipitoradial bursa. (orig.)
Purpose. To validate a protocol for creating virtual models to be used in the construction of solid prototypes useful for the planning-simulation of maxillo-facial surgery, in particular for very complex anatomical and pathologic problems. To optimize communications between the radiology, engineering and surgical laboratories. Methods and materials. We studied 16 patients with different clinical problems of the maxillo-facial district. Exams were performed with multidetector computed tomography (MDCT) and single slice computed tomography (SDCT) with axial scans and collimation of 0.5-2 mm, and reconstruction interval of 1 mm. Subsequently we performed 2D multiplanar reconstructions and 3D volume-rendering reconstructions. We exported the DICOM images to the engineering laboratory, to recognize and isolate the bony structures by software. With these data the solid prototypes were generated using stereolitography. To date, surgery has been ...
Colerectal cancer (CRC) is the second commonest cancer in the Western World. Successful treatment relies significantly on accurate detection and staging of primary disease as well as the early identification of the presence and extent of recurrence. Morphological imaging techniques, particularly computed tomography (CT), are well established and widely available to carry out these tasks in addition to predicting and monitoring response to therapy. This review analyses the current inadequacies for imaging CRC and critically assesses the potential role of functional imaging with positron emission tomography (PET). It was reviewed the current literature, to use the experience from the firs 1000 PET studies carried out at the institution and the perspective of surgical colleagues. It was found little evidence for the use of 2-["1"8F]fluoro-2-deoxy-D-glucose (FDG)-PET for screening asymptomatic individuals and current modalities appear better suited ...
The seismic reflection exploration technique which is one of the geophysical methods for oil exploration became effectively to image the subsurface structure with rapid development of computer. As a tool to perform seismic inversion, seismic forward modeling program using ray tracing should be developed. In this study, we have developed the algorithm that is to calculate the travel time of the complex geological structure using ray tracing by subdividing the geologic model into triangular element (finite element) having the constant velocity. We can analytically calculate Jacobian with some information by this current ray tracing. With this Jacobian, we will develop new algorithm which is to obtain geological properties and to image the subsurface. After subdividing subsurface into triangular element we shoot off the ray into subsurface by the Snell`s law. And then after taking the ray path which is similar to proper assumption we can calculate travel time. With this new ray tracing ...
A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10/sup 11/ m/(m/sup 2/-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83/sup 0/C +/- 8/sup 0/C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3/sup 0/ +/- 0.1/sup 0/ thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the simultaneous iterative reconstruction technique (SIRT) and the ...
A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10"1"1 m/(m"2-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83"0C +/- 8"0C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3"0 +/- 0.1"0 thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the simultaneous iterative reconstruction technique (SIRT) and the convolution method, were ...
Computerized tomography-guided neurolytic splanchnic nerve block is a technique for relieving abdominal cancer pain; the goal is the alcoholic neurolytic interruption of the sensitive structures in retroperitoneal space. Computerized tomography yields accurate anatomical detailing and the course for needle placement and alcohol spread. January, 1993, to July, 1996, twenty-one bilateral splanchnic nerve blocks were performed through the posterior access. Forty-eight hours after alcoholism. 14 patients (66%) had complete pain regression; 52% of the patients needed no analgesics for 6 to 54 days and only 9 patients (42%) needed another low opioid therapy. Complications included hypotension and diarrhea in all cases. One had a cardiac arrest and diet 8 days after the procedure. There were no other complications. The whole procedure usually lasted 60 min (range: 45 to 90 min). Splanchnic nerve neurolysis is a useful treatment in the patients with ...
The authors investigated the role of Computerized Tomography in guiding fine needle biopsy (FNB) in small (2 2 cm in diameter for CT-guided FNB sensitivity, specificity and diagnostic accuracy. Cytologic specimens were positive for malignancy in 40/52 cases (76.9%) and negative in 12 (23.1%). Clinical-surgical follow-up confirmed all the positive cytologic findings (40 cases), while 2 of the extant 12 cases were false negatives (95.20% sensitivity, 100% specificity and 96.15% diagnostic accuracy). 158 of 195 nodules > 2 cm in diameter and with clinical surgical follow-up (81.3%) were positive for malignancy and 34 were negative (17.43%) (98.75% sensitivity, 97.14% specificity and 98.46% diagnostic accuracy). Pneumothorax occurred in 33 patients (16.5%) with nodules > 2 cm in diameter as a complication of biopsy. Hemoptysis occurred in 15 patients (7.5%). In the whole group of lung lesions, the complications were pneumothorax in 80 patients (4.1%), hemoptysis ...
CRE is the French commission for energy regulation. CRE's remit is to assist in ensuring the proper operation of the electricity and natural gas markets for the benefit of the end-user. In particular, CRE ensures that the conditions of access to electricity and natural gas transmission and distribution systems do not hinder the development of competition. It monitors, for the electricity and natural gas sectors, all transactions made between suppliers, traders and producers, all transactions made on the organised markets and cross-border trading. It ensures that suppliers, traders and producers propose offers that are consistent with their financial and technical constraints. It monitors the implementation of and compliance with regulations giving consumers the right to choose their supplier in a competitive market, and allowing new suppliers to enter the market. This document is the 2008 activity report of CRE. Content: A - How CRE works: CRE regulatory authority and ...
The bibliography contains citations concerning waste treatment and disposal in the food processing industry. Methods, equipment, and technology are considered. References discuss waste heat recovery and examine treatment of wastes resulting from meat and seafood processing, dairy and beverage production, and fruit and vegetable processing. The citations explore conversion of the treated waste to fertilizer and for use in animal feeds, combustion for energy production, biogas production, and composting. The recovery and recycling of usable chemicals from the food waste are also covered. Food packaging recycling is considered in a related bibliography. (Contains 250 citations and includes a subject term index and title list.)
This ACDR was performed following completed of the Conceptual Design Report in July 1992; the work encompassed August 1992 to January 1994. Mission of the WRAP Module 2A facility is to receive, process, package, certify, and ship for permanent burial at the Hanford site disposal facilities the Category 1 and 3 contact handled low-level radioactive mixed wastes that are currently in retrievable storage at Hanford and are forecast to be generated over the next 30 years by Hanford, and waste to be shipped to Hanford from about DOE sites. This volume provides an introduction to the ACDR process and the scope of the task along with a project summary of the facility, treatment technologies, cost, and schedule. Major areas of departure from the CDR are highlighted. Descriptions of the facility layout and operations are included.
How to decide which mine surface tasks may be performed by industrial robots to improve productivity and working conditions is described. Charts are presented of the industrial tasks performed on the surface and how each task may be classified as light, average, difficult or very diffcult according to a defect criteria is explained (defective operations are those which involve, heavy, harmful, stressful or dangerous jobs). The results of these calculations are used to identify which operations are suitable for first introduction of robots since traditional automation methods cannot be used, e.g. various storage, loading and packaging tasks, coal selection, sorting and removal of foreign matter, provision of services such as food preparation, cleaning, etc. Robots may also be used to control automated operations that are monotonous and hazardous for human operators. It is envisaged that in the future computer programmed robots with artificial intelligence will ...
Radioactive waste shipping and receiving facilities presently planned for commercial and defence high level nuclear waste will handle waste packages at frequencies far in excess of those in common practice today. If current limits for radiation levels at the cask surface and current handling methods are used, high cumulative personnel exposure to ionizing radiation is projected to occur. To reduce these exposure levels, alternate handling methods are being developed and demonstrated. The production nature of cask receiving operations suggests commercial robotics be incorporated into a remote handling system to reduce predicted worker exposure to acceptable levels while maintaining or increasing throughput. The first phase of cask handling system development culminated in a proof-of-principle test demonstrating the feasibility of performing cask receiving and unloading operations in a remote and partially automated manner. (author).
Radioactive waste shipping and receiving facilities presently planned for commercial and defense high-level nuclear waste will handle waste packages at frequencies far in excess of those in common practice today. If current limits for radiation levels at the cask surface and current handling methods are used, high cumulative personnel exposure to ionizing radiation is projected to occur. To reduce these exposure levels, alternate handling methods are being developed and demonstrated. The production nature of cask receiving operations, suggests commercial robotics be incorporated into a remote handling system to reduce predicted worker exposure to acceptable levels while maintaining or increasing throughput. The first phase of cask handling system development culminated in a proof-of-principle test demonstrating the feasibility of performing cask receiving and unloading operations in a remote and partially automated manner.
Radioactive waste shipping and receiving facilities presently planned for commercial and defense nuclear waste will handle waste packages at frequencies far in excess of those in common practice today. Unacceptable personnel exposure to ionizing radiation is projected to occur if current limits for radiation levels at the cask surface and current handling methods are used. To reduce these exposure levels, alternate handling methods are being developed and demonstrated. The production nature of cask receiving operations suggests commercial robotics be incorporated into a remote handling system to reduce predicted worker exposure to acceptable levels, while maintaining or increasing throughput. The first phase of cask handling system development culminated in a proof-of-principle test demonstrating the feasibility of performing cask receiving and unloading operations in a remote and partially automated manner. 6 refs., 12 figs.
Volume V of the documentation for the Phase I Data Analysis Task performed in support of the current Regional Flow Model, Transport Model, and Risk Assessment for the Nevada Test Site Underground Test Area Subproject contains the transport parameter and source term data. Because of the size and complexity of the model area, a considerable quantity of data was collected and analyzed in support of the modeling efforts. The data analysis task was consequently broken into eight subtasks, and descriptions of each subtask's activities are contained in one of the eight volumes that comprise the Phase I Data Analysis Documentation.
Volume III of the documentation for the Phase I Data Analysis Task performed in support of the current Regional Flow Model, Transport Model, and Risk Assessment for the Nevada Test Site Underground Test Area Subproject contains the data covering groundwater recharge and discharge. Because of the size and complexity of the model area, a considerable quantity of data was collected and analyzed in support of the modeling efforts. The data analysis task was consequently broken into eight subtasks, and descriptions of each subtask's activities are contained in one of the eight volumes that comprise the Phase I Data Analysis Documentation.
Most plans for the disposition of surplus nuclear materials involve storage in sealed containers where the evolution of gases from reactions of adsorbed water could present both pressure and flammability hazards[l] . Despite efforts such as calcining the material to minimize the water content prior to packaging, both residual moisture and readsorbed water may be present in the final containers . Given the anticipated temperature excursions during transportation and storage, this water may thermally desorb, increasing the pressure, and/or thermally dissociate to produce H2 gas, increasing flammability hazards . In addition, the radiation from the nuclear material may induce radiolysis of the water with the likely products being water vapor, H2, 02 and H2O2. In order to better understand the relative importance of the thermal- and radiationinduced chemistry, we have studied the interactions of water on single crystals of uranium dioxide .
This book examines the applications of Monte Carlo (MC) calculations in therapeutic nuclear medicine, from basic principles to computer implementations of software packages and their applications in radiation dosimetry and treatment planning. It is written for nuclear medicine physicists and physicians as well as radiation oncologists, and can serve as a supplementary text for medical imaging, radiation dosimetry and nuclear engineering graduate courses in science, medical and engineering faculties. With chapters is written by recognised authorities in that particular field, the book covers the entire range of MC applications in therapeutic medical and health physics, from its use in imaging prior to therapy to dose distribution modelling targeted radiotherapy. The contributions discuss the fundamental concepts of radiation dosimetry, radiobiological aspects of targeted radionuclide therapy and the various components and steps required for implementing a dose ...
The objective of this study is development of technology on chicken yard design and its environment control. For this objective, the micro processor interface techniques and related programming techniques have been surveyed, and the chicken yard environment monitoring system has been developed that equipped with micro computer and signal measurement module. Software has also been developed that operated the system and analyzes measured data. By using micro computer and signal input/output module, the system can have various functions, such as monitoring, alarm, and data analysis function. Three dimensional graphic modeling of a chicken yard is performed using graphic package in this study. Application of three dimensional modeling technique make it easy to design chicken yard. 9 figs. (Author)
In the context of the LHC computing grid (LCG) project, the applications area develops and maintains that part of the physics applications software and associated infrastructure that is shared among the LHC experiments. The "physicist interface" (PI) project of the LCG application area encompasses the interfaces and tools by which physicists will directly use the software, providing implementations based on agreed standards like the analysis systems subsystem (AIDA) interfaces for data analysis. In collaboration with users from the experiments, work has started with implementing the AIDA interfaces for (binned and unbinned) histogramming, fitting and minimization as well as manipulation of tuples. These implementations have been developed by re-using existing packages either directly or by using a (thin) layer of wrappers. In addition, bindings of these interfaces to the Python interpreted language have been done using the dictionary subsystem of the LCG ...
In the context of the LHC Computing Grid (LCG) project, the Applications Area develops and maintains that part of the physics applications software and associated infrastructure that is shared among the LHC experiments. The "Physicist Interface" (PI) project of the LCG Application Area encompasses the interfaces and tools by which physicists will directly use the software, providing implementations based on agreed standards like the AIDA interfaces for data analysis. In collaboration with users from the experiments, work has started with implementing the AIDA interfaces for (binned and unbinned) histogramming, fitting and minimization as well as manipulation of tuples. These implementations have been developed by re-using existing packages either directly or by using a (thin) layer of wrappers. In addition, bindings of these interfaces to the Python interpreted language have been done using the dictionary subsystem of the LCG-AA/SEAL project. The actual status and ...
Glass ceramics are commonly used as sealing materials for planar solid oxide fuel cells (SOFCs). The major requirements of stack and module builders for these materials are the stability of the coefficient of thermal expansion (CTE), excellent bonding (sticking) behaviour and the absence of volatile ingredients, which can lead to changes of the material properties and the sealing ability. SCHOTT Electronic Packaging has developed special glasses and glass-ceramics for various solid oxide fuel cell designs and operating temperatures. The glass compositions are based on the system MgO-Al2O3-BaO-SiO2-B2O3. In this study the evaluation of the developed materials was done by high temperature aging tests for up to 1000h, high temperature XRD-studies and Rietveld calculations, combined with scann...
The structural, electronic and optical properties of ZnX and CdX (X = Se, Te and S) are studied using density functional theory by the Wien2k package. The energy band gap, real and imaginary parts of the dielectric function, energy loss function, optical absorption coefficient and reflectivity spectra of these compounds are calculated. The Engel-Vosko approach improves the energy band gaps of ZnX and CdX compounds. The calculated optical parameters are in good agreement with available experimental results, particularly in the Engel-Vosko approach. Furthermore the effect of hydrostatic pressure on the energy band gap, the real and imaginary parts of the dielectric function of these compounds is studied. The first and second order pressure coefficient for the energy band gaps, the static dielectric function and the static reflectivity spectra are calculated.
This manual is intended to serve several purposes. The first goal is to describe the capabilities and operation of the SMC processor package from an operator or user point of view. Secondly, the manual will describe in some detail the basic hardware elements and how they can be used effectively to implement a step motor control system. Practical information on the use, installation and checkout of the hardware set is presented in the following sections along with programming suggestions. Available related system software is described in this manual for reference and as an aid in understanding the system architecture. Section two presents an overview and operations manual of the SMC processor describing its composition and functional capabilities. Section three contains hardware descriptions in some detail for the LLL-designed hardware used in the SMC processor. Basic theory of operation and important features are explained.
A sensitivity analysis was conducted to evaluate the technical issues pertaining to possible destructive interactions between spent nuclear fuels (SNFs) and the stainless steel canisters. When issues are identified through such an analysis, they provide the technical basis for answering what if questions and, if needed, for conducting additional analyses, testing, or other efforts to resolve them in order to base the licensing on solid technical grounds. The analysis reported herein systematically assessed the chemical and physical properties and the potential interactions of the materials that comprise typical US Department of Energy (DOE) SNFs and the stainless steel canisters in which they will be stored, transported, and placed in a geologic repository for final disposition. The primary focus in each step of the analysis was to identify any possible phenomena that could potentially compromise the structural integrity of the canisters and to assess their thermodynamic feasibility
A numerical package called RESID has been assembled to calculate the residual stresses in VAWT blades induced during cold forming. Using a strength of materials - elementary beam theory approach, RESID models the material response with a bilinear stress-strain curve, and the cross-sectional geometry with an array of area increments. Through an iterative solution procedure residual stresses are predicted for a specified final radius of curvature or applied bending moment. RESID results are compared to theoretical solutions for simple geometries and with MARC Finite element results for VAWT blade geometries. Calculating residual stress levels, determining acceptable residual stress levels, and a method of reducing residual stresses are discussed. A complete listing and sample run are included in the appendicies.
The efficient design of computation intensive multidimensional signal processing applications requires dealing with three kinds of constraints: those implied by the data dependencies, the non-functional requirements (real-time, power consumption) and resources availability of the execution platform. Modeling and Analysis of Real-time and Embedded systems (MARTE) UML profile through its repetitive structure modeling (RSM) package is well suited to model the inherent parallelism within these applications, a compact representation of parallel execution platforms and the distributive mapping of one on another. The execution of such a specification respects the whole set of constraints defined upon, while the quality of the scheduling is directly linked to the quality of the mapping of the mult...
The first part of the study contains a literature compilation of more than 50 original publications reporting the radiation induced effects in 17 different high polymer materials and glass which are relevant in the manufacturing of medical devices or packing materials. The results collected demonstrate that high energy radiation, i.e. gamma- or X-rays, causes various physical and chemical alterations in high polymer materials. A detailed summary and discussion of the results of the original publications is not included in the present report, it will be presented in the second part of the study. Furthermore, the second part of the study will refer to the aspect of wholesomeness of irradiated medical devices or packing materials in a more general manner of representation. (orig.).
The Savannah River Site disposes of low-level radioactive waste within on-site engineered disposal facilities. The Savannah River Site must demonstrate that these disposals meet the requirements of DOE Order 435 . 1 through a process known as performance assessment (PA). The objective of this document is to provide the radionuclide -specific data needed for the PA calculations . This work is part of an on-going program to periodically review and update existing PA work as new data becomes available. Revision of the E -Area Low-Level Waste Facility PA is currently underway. The number of radionuclides selected to undergo detailed analysis in the PA is determined by a screening process. The basis of this process is described. Radionuclide-specific data for half-lives, decay modes, daughters, dose conversion factors and groundwater concentration limits are presented with source references and methodologies.
Actinide recycling by partitioning and transmutation is considered as one of the most promising strategies to reduce the inventory of radioactive waste, thus contributing to make nuclear energy sustainable. To make advances beyond the current state of the art in pyrochemical separations processes, the Domain 2 (DM2) of ACSEPT has been built on considering a process approach based on system studied. Four work packages that represent the main steps of a process block diagram have been identified: head-end steps, core process development, and salt treatment for recycling and waste conditioning. The results obtained in this domain will be integrated in DM 3 (Process) in order to orientate the R and D studies of DM2 and to propose and validate flowsheets at the end of the project. The state of the art on pyrochemical separation within the European Community and the working program of ACSEPT in pyrometallurgy are presented in this work. (authors)
Peculiarities of Kurchatov Institute WWR-2 and TR research reactors spent fuel treating and transportation for radiochemical processing are stated. Spent fuels were performed as fuel assemblies of different forms and containing similar fuel elements: EhK-10 with 10% enrichment UO2-Mg fuel kernels or S-36 with 36% enrichment U-Al alloys. Spent fuel storage conditions are described. Features of developed procedures for identification of fuel assemblies by type of fuel elements are given. Transport package TUK-19 for loading and transportation of spent fuel for processing was chosen. Details of spent fuel loading in TUK-19 that is conducted by personnel under protective sheet of water in special reclaim volume are described
Abstract A series of polypropylene carbonate (PPC)/ZnO nanocomposite films with different ZnO contents were prepared via a solution blending method. The morphological structures, thermal properties, oxygen permeability, water sorption, and antibacterial properties of the films were investigated as a function of ZnO concentration. While all of the composite films with less than 5 wt % ZnO exhibited good dispersion of ZnO in the PPC matrix, FTIR and SEM results revealed that solution blending did not lead to a strong interaction between PPC and unmodified ZnO. As such, poor dispersion was induced in the composite films with a high ZnO content. By incorporating inorganic ZnO filler nanoparticles, the diffusion coefficient, water uptake in equilibrium, and oxygen permeability decreased as the ...
To establish the phylogeographic relationships in rabies viruses in Brazil, we studied a dataset retrieved from GenBank consisting of 71 genetic sequences from the coding region of the N gene of rabies viruses isolated in dogs over a period of 22?years. The Bayesian Markov chain Monte Carlo method available in the BEAST package was used with the GTR+G+?4 evolutionary model in conjunction with the relaxed uncorrelated lognormal molecular clock model and an exponential growth tree prior. A discrete phylogeographic diffusion model was also analyzed using a standard continuous-time Markov chain viewed with Google Earth to provide a spatial projection of the diffusion of genetic lineages based on their phylogeographic relationships. The topology of the time and substitution phylogenetic trees a...
Basic information on photovoltaic conversion technology is provided for those unfamiliar with the field. Various types of photovoltaic products and systems currently available off-the-shelf are described. These include products without batteries, battery chargers, power packages, home electric systems, and partial systems. Procedures are given for designing a photovoltaic system from scratch. A few custom photovoltaic systems are described, and a list is compiled of photovoltaic firms which can provide custom systems. Guidance is offered for deciding whether or not to use photovoltaic products. A variety of installations are described and their performance is appraised by the owners. Information is given on various financial incentives available from state and federal governments. Sources of additional information on photovoltaics are listed. A matrix is provided indicating the sources of various types of photovoltaic products. The addresses of suppliers are ...
The detection of explosives is a notoriously difficult problem, especially at stand-off distances, due to their (generally) low vapor pressure, environmental and matrix interferences, and packaging. We are exploring optimal dynamic detection to exploit the best capabilities of recent advances in laser technology and recent discoveries in optimal shaping of laser pulses for control of molecular processes to significantly enhance the standoff detection of explosives. The core of the ODD-Ex technique is the introduction of optimally shaped laser pulses to simultaneously enhance sensitivity of explosives signatures while reducing the influence of noise and the signals from background interferents in the field (increase selectivity). These goals are being addressed by operating in an optimal nonlinear fashion, typically with a single shaped laser pulse inherently containing within it coherently locked control and probe sub-pulses. With sufficient bandwidth, the ...
In this paper, we report an optical fiber sensor for measuring temperature based on bimetallic concept. The sensor is designed by following the basic principle of Fabry-Perot interferometer and theoretical detail of the sensor has been outlined here with a numerical study. An important feature of the proposed sensor is that the fabrication will be done on a commercial multimode optical fiber. The Micro-Electro-Mechanical Systems (MEMS) based fabrication process could be performed directly on a multimode optical fiber end face which will eliminate the need for adhesive in packaging. The sensor could be fabricated as sensor arrays for micro level applications. The potential application of the proposed optical sensor includes biomedical applications, nano research, microfluidics, and other ME...
The electronic structure and optical properties in tetragonal ceramics PbTiO_3, are studied by using full-potential linearized augmented plane wave method in density functional theory with the generalized gradient approximation by WIEN2K package. The theoretical calculated optical properties and energy loss spectrum yield a static refractive index of 2.59 and a plasmon energy of 22.7eV for the tetragonal phase. The effective electron number at low energy saturates near 22-23eV with the value of 50 for the effective electron number. The results show a indirect band gap of 2.2eV at the I' point in the Brillouin zone. The :calculated band structure and density of states of PbTiO_3 agree with previous experimental and theoretical results.
Boiling jet impingement cooling is currently being explored to cool power electronics components. In hybrid vehicles, inverters are used for DC-AC conversion. These inverters involve a number of insulated-gate bipolar transistors (IGBTs), which are used as on/off switches. The heat dissipated in these transistors can result in heat fluxes of up to 200 W/cm{sup 2}, which makes the thermal management problem quite important. In this paper, turbulent jet impingement involving nucleate boiling is explored numerically. The framework for these computations is the CFD code FLUENT. For nucleate boiling, the Eulerian multiphase model is used. The numerical results for boiling water and R113 jets (submerged) are validated against existing experimental data in the literature. Some representative IGBT package simulations that use R134a as the cooling fluid are also presented. (author)
The fundamental points to be considered in a waste treatment system for a country like Japan, where the final disposal method has not been decided and the wastes have to be stored in the power plants, are volume reduction of the wastes, safe storage of the wastes in the plant, and flexibility regarding the final disposal. A system has been developed that consists of a thin film evaporator for the direct solidification of the liquid waste, a pelletizer for producing hard pellets from the powdered wastes, a pellet storage unit, and a solidification unit for the final disposal. A pilot plant with waste treatment capacity of 200 kg/h was built in 1976 and has proved the system feasibility. This paper reports on pilot plant tests of the thin film evaporator and other components, tests on pellet deterioration during long term storage, and integrity tests on the final disposal of the pellet bitumen package.
The fundamental points to be considered in a waste treatment system for a country like Japan, where the final disposal method has not been decided and the wastes have to be stored in the power plants, are volume reduction of the wastes, safe storage of the wastes in the plant, and flexibility regarding the final disposal. A system has been developed that consists of a thin film evaporator for the direct solidification of the liquid waste, a pelletizer for producing hard pellets from the powdered wastes, a pellet storage unit, and a solidification unit for the final disposal. A pilot plant with waste treatment capacity of 200 kg/h was built in 1976 and has proved the system feasibility. This paper reports on pilot plant tests of the thin film evaporator and other components, tests on pellet deterioration during long term storage, and integrity tests on the final disposal of the pellet bitumen package.
Electric Fuel Ltd. is engaged in the design, development and commercialization of its proprietary zinc/air battery technology for electric vehicles, consumer electronic products and defence applications. To meet the challenging requirements for propelling an all-electric bus, the Vehicle Division sought a unique solution: an all electric battery-battery hybrid propulsion system. The high energy zinc/air battery is coupled with a high-power auxiliary battery. The combined system offers zero emission, high power and long range in an economically viable package. The consumer battery group has developed a high power primary zinc/air cell aimed at cellular phone users, offering extended use, convenience and low cost. (orig.)
Since August 1984, the MITRE Corporation has been supporting the Naval Sea Systems Command (NAVSEA) and the Naval Medical Command (NAVMEDCOM) in their joint efforts to enhance the Navy Occupational Health Information Management System (NOHIMS). The goal of the enhancement effort was to create a comprehensive occupational health and safety system for Navy industrial facilities by expanding upon the original NOHIMS functions and adding modules for hazard deficiency abatement, hazardous-material control, injury claims and compensation, and safety and health training. To meet this goal, MITRE developed an enhanced industrial subsystem, referred to as the Occupational Safety and Health Record Keeping System (OSHRKS), using a prototyping approach and a public-domain data base-management software package, the Veterans Administration's (VA's) FileManager (FileMan).
In this report we present a suite of subroutines for the solution of sparse unsymmetric sets of linear equations using a variant of Gaussian elimination. The subroutines are divided into three distinct phases. The first phase optionally preorders the matrix to block triangular form and then performs a sparsity oriented factorization, the second factorizes a matrix of a similar sparsity pattern, while the third uses these decompositions to solve the equations. In this revised edition, the actual Fortran listings have been replaced by a reference to their availability in machine readable form. Other changes to the first edition are minor. This revision is essentially a reprint of the 1979 revision, the only changes being that the MA28A specification sheet has been typeset and has a few minor changes and the existence of a version of the package for complex equations is announced. 11 refs., 11 tabs.
The losses of Hg from phenol formaldehyde resin - bound standards and hair samples in neutron activation analysis in case of their irradiation in the water filled nuclear reactor channel is studied. The mean losses of Hg during 20-30 hrs irradiation at (2-3)x10"1"8 n/cm"2 are 15-20% with their stopping at double Al-covers. The mean losses of Hg from standards at 200, 250 and 300 deg C are 30, 61 and 86% respectively and do not occur at 150 deg C after their 5 hour heating. The losses of Hg from hair samples packed in polyethylene tubes through the package walls in experimental conditions are not observed.
In the Introduction the history of the cascade probabilistic method development is described. The calculation model for different charged particles cascade probabilistic functions (CPF) was considered. A new analytical expressions for CPF for electrons, protons, alpha-particles and ions are obtained as well. A new results on mathematical analysis, algorithms, and calculation of CPF with taking into account charged particles energy losses on computer are cited. The peculiarities of these functions are analyzed. The detail analysis of these function behavior in relation from flying particles energy, target atomic number, generation and registration depth, and interactions number is carried out. The program packages in the Windows medium is developed on the visual programming languages: Visual Basic 6.0, Delphi 6.0, C++ Builder 6.0.
The present conference on lens design encompasses physical and geometrical optics, diffractive optics, the optimization of optical design, software packages, ray tracing, the use of artificial intelligence, the achromatization of materials, zoom optics, microoptics and GRIN lenses, and IR lens design. Specific issues addressed include diffraction-performance calculations in lens design, the optimization of the optical transfer function, a rank-down method for automatic lens design, applications of quadric surfaces, the correction of aberrations by using HOEs in UV and visible imaging systems, and an all-refractive telescope for intersatellite communications. Also addressed are automation techniques for optics manufacturing, all-reflective phased-array imaging telescopes, the thermal aberration analysis of a Nd:YAG laser, the analysis of illumination systems, athermalized FLIR optics, and the design of array systems using shared symmetry.
Conventional interconnect and switching technology is rapidly becoming a critical issue in the realization of systems using high speed silicon and GaAs based technologies. In recent years clock speeds and on-chip density for VLSI/VHSIC technology has made packaging these high speed chips extremely difficult. A strong case can be made for using optical interconnects for on-chip/on-wafer, chip-to-chip and board-to-board high speed communications. GaAs integrated optoelectronic circuits (IOC's) are being developed in a number of laboratories for performing Input/Output functions at all levels. In this paper integrated optoelectronic materials, electronics and optoelectronic devices are presented. IOC's are examined from the standpoint of what it takes to fabricate the devices and what performance can be expected.
To eliminate their classical brittleness and flexibility problems zein films were plasticized by incorporation of different phenolic acids (gallic acid (GA), p-hydroxy benzoic acid (HBA) or ferulic acids (FA)) or flavonoids (catechin (CAT), flavone (FLA) or quercetin (QU)). The use of GA, CAT, FA and HBA at 3 mg/cm2 eliminated the brittleness of films and gave highly flexible films showing elongations between 135% and 189%, while FLA and QU caused no considerable effect on film elongation. The films containing FA and HBA showed extreme swelling and lost their structural integrity when hydrated in distilled water. In contrast, CAT and GA containing films maintained their integrity following hydration. Most of the GA (up to 93%) and a considerable portion of CAT (up to 60%) in the films exis...
This research aims to develop reliable, advanced system thermal-hydraulic computer code and to quantify the uncertainties of code to introduce the best estimate methodology of ECCS for LBLOCA. Although the one of best estimate code, RELAP5/MOD3.1 was introduced from USNRC, several deficiencies in its reflood model and some improvements have been made. The improvements consist of modification of reflood wall heat transfer package and adjusting the drop size in dispersed flow regime. The tome smoothing of wall vaporization and level tracking model are also added to eliminate the pressure spike and level oscillation. For the verification of improved model and quantification of associated uncertainty, the FLECHT-SEASET data were used and upper limit of uncertainty at 95% confidence level is evaluated. (Author) 30 refs., 49 figs., 2 tabs.
Fresh and fresh-cut tomatoes have been associated with numerous outbreaks of salmonellosis in recent years. One effective post harvest treatment to reduce Salmonella enterica in tomatoes may be high pressure processing (HPP). The objectives of the study were to determine the potential for HPP to reduce S. enterica serovars Newport, Javiana, Braenderup and Anatum in tryptic soy broth (TSB) and to determine the effect of HPP to reduce the most pressure resistant of the four serovars from fresh diced and whole tomatoes. To evaluate pressure resistance, TSB containing 8 log CFU/ml of one of the four serovars was packaged in sterile stomacher bags and subjected to one of three different pressures (350, 450 or 550MPa) for 120s. The most pressure resistant S. enterica serovar evaluated was Braend...
With the ubiquitous availability of commercial VME modules and interface chips many experiments in all branches of Experimental Physics are turning to VME as the module packaging and backplane protocol of choice for application specific modules. The current VME backplane, electrical, and mechanical standards are clearly lacking when it comes to implementing the analogue and digital front end modules that Physics experiments rely on to provide the needed high speed and intelligent solutions to their data collection requirements. To address these needs the European ESONE and American VME-P committees are collaborating with the ANSII and ISO standards committees, and the VME VITA/VSO manufacturers associations, to define standard extensions to the VME protocols for such HEP needs as ``sparse data scans``, standard uses and implementations of previously user defined pins and connectors, standardization of the 9U form factor VME cards etc. This paper reports on the ...
During the past few decades, the basic assumption of agroclimatic zoning, i.e., that agroclimatic conditions remain relatively stable, has been shattered by ongoing climate change. The first aim of this study was to develop a tool that would allow for effective analysis of various agroclimatic indicators and their dynamics under climate change conditions for a particular region. The results of this effort were summarized in the AgriClim software package, which provides users with a wide range of parameters essential for the evaluation of climate-related stress factors in agricultural crop production. The software was then tested over an area of 114,000?km2 in Central Europe. We have found that by 2020, the combination of increased air temperature and changes in the amount and distribution ...
With the issuance of the Decommissioning Rule (July 27, 1988), nuclear power plant licensees are required to submit to the US Regulatory Commission (NRC) for review, decommissioning plans and cost estimates. This user`s manual and the accompanying Cost Estimating Computer Program (CECP) software provide a cost-calculating methodology to the NRC staff that will assist them in assessing the adequacy of the licensee submittals. The CECP, designed to be used on a personnel computer, provides estimates for the cost of decommissioning PWR plant stations to the point of license termination. Such cost estimates include component, piping, and equipment removal costs; packaging costs; decontamination costs; transportation costs; burial costs; and manpower costs. In addition to costs, the CECP also calculates burial volumes, person-hours, crew-hours, and exposure person-hours associated with decommissioning.
The aim of this study is to compare, from an environmental point of view, different alternatives for the management of municipal solid waste generated in the town of Castellon de la Plana (Spain). This town currently produces 207ton of waste per day and the waste management system employed today involves the collection of paper/cardboard, glass and light packaging from materials banks and of rest waste at street-side containers. The proposed alternative scenarios were based on a combination of the following elements: selective collection targets to be accomplished by the year 2015 as specified in the Spanish National Waste Plan (assuming they are reached to an extent of 50% and 100%), different collection models implemented nationally, and diverse treatments of both the separated biodegrad...
Dimensioning of actinides waste packages for long duration storage has to take into account helium production from natural decay and release rates from the material. For the latter, we propose here an improved method for the determination of the helium diffusion coefficient in britholite, to be used for minor actinides storage. This work is based on results we previously published using the classical three steps method: "3He implantation on a Van de Graaff facility, "3He profile determination analysing the protons resulting from the "3He(d,p)"4He reaction in a nuclear microprobe, evolution of the helium profile during annealings. Taking explicitly into account the incident deuterons energy stragglings allows us to show that the implanted helium profiles are bimodal, each component leading to a different helium diffusion coefficient.
Ba, Cd, Cr, Cu, Fe, Ni, Pb and Zn were determined in birch leaves (Folium Betulae), dandelion roots (Radix Taraxacae), hawthorn blossom (Inflorescentia Crataegi) and their infusions by graphite furnace atomic absorption spectrometry (GFAAS) after microwave digestion of plant samples. Infusions were made from herbs according to prescription for patients, provided by the producer of medicine on the package. The results obtained were compared with daily requirements for each element. Results show high content of cadmium in the medicinal plants analyzed. The highest level in infusions was observed for Ni and Zn (over 90% of the total element concentration for Ni and in most cases over 50% for Zn), and the lowest for Cd and Pb. The calculated daily intake of majority of the analyzed elements was very low (under 1% of daily requirements)
The work presented in this paper is part of the cooperative research project AUTO-OPT carried out by twelve partners from the automotive industries. One major work package concerns the application of data mining methods in the area of automotive design. Suitable methods for data preparation and data analysis are developed. The objective of the work is the re-use of data stored in the crash-simulation department at BMW in order to gain deeper insight into the interrelations between the geometric variations of the car during its design and its performance in crash testing. In this paper a method for data analysis of finite element models and results from crash simulation is proposed and application to recent data from the industrial partner BMW is demonstrated. All necessary steps from data pre-processing to re-integration into the working environment of the engineer are covered.
Recently, foods are often exposed to radiation under packed states with various wrapping materials. In this study, the effects of #gamma#-ray radiation were investigated on the additives in wrapping materials on the market. 10 - 50 kGy #gamma# radiation was irradiated to samples under sealed condition in a glass-ware. Polyethylene bag and wrapping film, polypropylene wrapping film, cup and sheet, and polystyrene cup were used as samples. And the additives in these materials were analyzed by GC/MS to evaluate the radiation effects on them. The irradiation was found to induce rapid degradation of antioxidants, especially, Irgafos 168. Some fatty acid amides used as a lubricant and a plasticizer, DBP were also reduced, but not aliphatic hydrocarbons. However, all polystyrene products used in this study included no additives. The contents of styrene dimer and trimer in those wrapping materials were not changed by #gamma#-irradiation. (M.N.)
Cellulose sausage cellulose casings are used extensively in the manufacture of sausages in meat packaging. After stripping the meat, spent casings mainly contain cellulose and residual meat juice with salt, nitrate and nitrite. Disposal of spent sausage casings has serious economic and environmental concerns for the sausage industry. This work describes bioconversion of spent cellulose casings (SCC) into enzymes, lactic acid and ethanol by using cellulolytic fungi, lactobacillus and yeasts. The solid substrate cultivation (SSC) of Trichoderma reesei RUT C-30 on SCC and blends gave a maximum of 152 filter paper cellulase (FPase) activity and about 100 carboxymethylcellulase activity (CMCase)/g dry weight substrate. The SSC produced enzyme-rich casing with 50 FPase when directly mixed as suc...
The Jeanne d`Arc Basin is located 320 km offshore in the Grand Banks of Newfoundland. It is a Mesozoic failed-rift basin with recoverable oil reserves of about 2 billion barrels. Its huge Hibernia Field will be in production by late 1997. The basin has been reappraised using sequence stratigraphic concepts, and renewed exploration in the area is expected. The Upper Jurassic - Lower Cretaceous sedimentary accumulation in the Basin was formed by the extensional tectonics that created the North Atlantic Ocean. The sedimentary packages were placed in chronostratigraphic order by calibrating the biostratigraphy of the Oxfordian to Maastrichtian section to the detailed ammonite zonation from the North Sea.
This manuscript is a contribution on the modeling of H.263 traffic in multipoint videoconference sessions over IP Networks. Our study includes analysis and modeling assessment of extensive data gathered during realistic videoconference sessions between commercial H.263-compliant terminal clients (with different videoconference software packages installed). All terminal clients were communicating through a Multipoint Control Unit (software or hardware MCU) at `switched presence' mode and for comparative purposes the same typical videoconference content (a person speaking, with mild movement and occasional zoom/span) was used. The analysis of the H.263 data at the frame level suggests that the traffic from the different terminals to the MCU can be represented by a stationary stochastic proce...
In the absence of empirical outdoor thermal comfort studies it has been widely assumed that indoor thermal comfort theory generalises to outdoor settings without modification. Many indoor models were developed to describe thermal discomfort, not stress, therefore their relevance to conditions that vary greatly from neutrality, as many outdoor climatic conditions do, has not been critically validated in the field to date. The thermal comfort of 1018 subjects in outdoor and semi-outdoor locations in subtropical Sydney was investigated by a questionnaire and a comprehensive package of micro-meteorological instruments. The thermal neutrality in terms of the thermal comfort index OUT{sub S}ET* of 26.2 {sup o}C was significantly higher than the indoor SET* counterpart of 24{sup o}C (ASHRAE Trans. 92 (1986) 709). (author)
In the last months several ballon and satellite experiments improved significantly our knowledge of cosmic ray (CR) spectra at high energy. In particular CREAM allowed to measure B/C, C/O and N/O ratios up to 1 TeV/n and PAMELA the anti p/p ratio up to 100 GeV with unprecedented accuracy. These measurements offer a valuable probe of CR propagation properties. We performed a statistical analysis to test the compatibility of these results, as well as other most significant experimental data, with the predictions of a new numerical CR diffusion package (DRAGON). We found that above 1 GeV/n all data are consistent with a plain diffusion scenario and point to well defined ranges for the normalization and energy dependence of the diffusion coefficient. (orig.)
This paper gives a concise overview of evolutionary algorithms for multiobjective optimization. A substantial number of evolutionary computation methods for multiobjective problem solving has been proposed so far, and an attempt of unifying existing approaches is here presented. Based on a fine-grained decomposition and following the main issues of fitness assignment, diversity preservation and elitism, a conceptual global model is proposed and is validated by regarding a number of state-of-the-art algorithms as simple variants of the same structure. The presented model is then incorporated into a general-purpose software framework dedicated to the design and the implementation of evolutionary multiobjective optimization techniques: ParadisEO-MOEO. This package has proven its validity and flexibility by enabling the resolution of many real-world and hard multiobjective optimization problems.