Automaticity and conduction properties of bio-artificial pacemakers assessed in an in vitro monolayer model of neonatal rat ventricular myocytes  

UK PubMed Central (United Kingdom)

AimsA better understanding of the ionic mechanisms for cardiac automaticity can lead to better strategies for engineering bio-artificial pacemakers. Here, we attempted to better...Full Text Available

2010-08-01

2

[Effects of 50 to 60 Hz and of 20 to 50 kHz magnetic fields on the operation of implanted cardiac pacemakers].  

Science.gov (United States)

The effect of 50 Hz and 60 Hz (frequencies of current distribution) and 20 kHz to 50 kHz (frequencies of induction cooktop) magnetic interference on implanted pacemakers have been assessed with the present generation of device technology. Sixty patients implanted in 1998 and 1999 with dual chamber pacemakers from 9 different manufacturers were monitored with telemetry while passing through, and standing between a system of two coils. They generated a 50 Hz or a 60 Hz magnetic field at 50 microT. Then, patients used a cooktop at different power. The recordings were made with the standard setting of "medically correct" sensing parameters chosen for the patients. Then pacemakers were reprogrammed to the unipolar mode, with the highest atrial (A) and ventricular (V) sensitivity that did not induce muscular inhibition while moving. Between each exposure (50 Hz, 60 Hz or 20 kHz to 50 kHz), the pacemaker ...

2003-04-01

3

Real-time monitoring of circadian clock oscillations in primary cultures of mammalian cells using Tol2 transposon-mediated gene transfer strategy  

UK PubMed Central (United Kingdom)

BackgroundThe circadian rhythm in mammals is orchestrated by a central pacemaker in the brain, but most peripheral tissues contain their own intrinsic circadian oscillators. The...Full Text Available

4

Intrinsic near-24-h pacemaker period determines limits of circadian entrainment to a weak synchronizer in humans  

UK PubMed Central (United Kingdom)

Endogenous circadian clocks are robust regulators of physiology and behavior. Synchronization or entrainment of biological clocks to environmental time is adaptive and important for physiological homeostasis...Full Text Available

2001-11-20

5

Electromagnetic fields, pacemakers and defibrillators; Champs electromagnetiques, cardiostimulateurs et defibrillateurs  

Energy Technology Data Exchange (ETDEWEB)

Presentation of electromagnetic sources constituted by various radio transmitters contributing to different radio communication services in the environment. Results of a measures campaign to assess the electromagnetic field in the close neighbourhood of various stations. Analysis by frequency domains. (author)

2004-07-01

6

Trends in Neuroendocrinology  

British Library Electronic Table of Contents (United Kingdom)

The mammalian circadian timing system is organized into hierarchical structures with a central clock in the suprachiasmatic nucleus (SCN) and subsidiary peripheral oscillators. After the discovery of the local clockwork in peripheral organs and tissues, which have a molecular makeup similar to the central pacemaker SCN, uncovering the roles of the peripheral clock in the rhythmic physiology has been an emerging goal in chronobiology. Glucocorticoid (GC) is a multifunctional adrenal steroid hormone that shows a robust circadian rhythm. The daily GC rhythm has long been thought to be governed by the SCN via the hypothalamus-pituitary-adrenal neuroendocrine axis. Recent findings, however, indicate that multiple regulatory mechanisms, including the adrenal intrinsic mechanism by the peripheral...

2011-01-01

7

Radio cellular phones and health: Up-to-date research on human health; Radiotelephones cellulaires et sante: mise au point des recherches portant sur la sante chez l'homme  

Energy Technology Data Exchange (ETDEWEB)

Cellular telephones emit a radiofrequency electromagnetic field, part of which is absorbed in the user's head. Many studies have been conducted to look for their possible health hazard to human, at the experimental, epidemiological or clinical level. After a short recall on dosimetry, the author describes the state-of-the art about harmful and irreversible effects, up to now not confirmed, and about some benign symptoms which look absolutely actual. A causal relationship of the electromagnetic field on these benign symptoms is however not proven; other, studies are running to evaluate their possible long-term consequences. Interferences with cardiac pacemakers can easily be avoided by holding the telephone handset farther than 10 cm. (author)

1999-12-01

8

Localization of small magnets against a noisy background  

Science.gov (United States)

Effective localization of small magnets against a noisy, real world background can involve various methods to first identify the magnetic fields produced by the magnet of interest, then to filter out background noise, and then to analyze the available magnetic field data to localize the magnet. Here we discuss low cost techniques which allow localization of small magnets with field strengths in the milliGauss range against real world background fields in the range of hundreds of mG, which may be fluctuating by up to tens of mG. Such techniques allow magnet tracking to be used to localize catheters in place of more invasive and expensive methods, e.g. fluoroscopy, for a variety of applications, including drug infusion with peripherally inserted central catheters (PICCs), laser ablation (TMR, PTMR) and introduction of pacemaker leads.

2001-05-01

9

Dissection of the thoracic aorta - role of CT and MRT following aortic replacement  

International Nuclear Information System (INIS)

Dynamic CT and MRT were performed in 21 patients who had undergone prosthetic replacement of the aorta because of dissection of the thoracic aorta. There is no difference between MRI and dynamic CT in the demonstration of a persistent intimal flap, the formation of a thrombus and the assessment of the aortic diameter in patients who underwent surgery for thoraco-abdominal aortic dissection. MRI, however, is superior in the identification of the true and false lumen and the demonstration of the distal anastomotic site. The major advantages of MRI are that there is no need for intravenous contrast agents, that it is high sensitive to flow phenomena, and that it can demonstrate the aortic arch and the ascending aorta on sagittal oblique sections. The major disadvantages of MRI are the limited access to the patient during the procedure, and the inability to examine patients fitted with pacemakers or who are on assisted ventilation. Today, MRI is considered the method ...

10

Danger: high voltage  

Science.gov (United States)

Electric utilities have been surprised by recent opposition to the construction of very-high-voltage transmission lines, which met with little resistance in the past. Concerns over health and safety factors are associated with the increase in the number of such lines, although their presence has always been an inconvenience and a hazard for those living and working in the immediate vicinity. The new lines present additional hazards due to the continuous flow of small electric currents and the charges that build up in the area of the towers and lines. The lines are also a threat to persons wearing cardiac pacemakers. There is experimental evidence from the Soviet Union and the U.S. that electric and magnetic fields at the frequencies of such power lines can have serious biological effects on growth rates and the functioning of the central nervous system. Full disclosure that possible risks are involved and the opportunity to avoid these risks is a public ...

1978-05-01

11

Cardiac Pacing: Memories of a Bygone Era  

British Library Electronic Table of Contents (United Kingdom)

The first cardiac pacemaker implants occurred in the late 1950s and involved insertion of epicardial or epimyocardial leads and abdominal pulse generators. By the mid 1960s, cardiologists were making attempts to insert transvenous leads into the right ventricle. These early unipolar leads had large, polished, high polarization electrodes, no fixation device, and no lumen in which to place a stylet for lead positioning. The lead implantation procedures were usually long and the irradiation to both patient and operator excessive. Pulse generators were powered by zinc-mercury cells, which were large, unreliable, and prone to sudden output failure. Postoperative complications such as lead dislodgement, exit block, and premature power source failure were very common with most patients requiring...

2008-01-01

12

Biological effects and physical safety aspects of NMR imaging and in vivo spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

An assessment is made of the biological effects and physical hazards of static and time-varying fields associated with the NMR devices that are being used for clinical imaging and in vivo spectroscopy. A summary is given of the current state of knowledge concerning the mechanisms of interaction and the bioeffects of these fields. Additional topics that are discussed include: (1) physical effects on pacemakers and metallic implants such as aneurysm clips, (2) human health studies related to the effects of exposure to nonionizing electromagnetic radiation, and (3) extant guidelines for limiting exposure of patients and medical personnel to the fields produced by NMR devices. On the basis of information available at the present time, it is concluded that the fields associated with the current generation of NMR devices do not pose a significant health risk in themselves. However, rigorous guidelines must be followed to avoid the physical interaction of these fields ...

1985-08-01

13

Retrieval of intravascular foreign bodies with goose neck snare  

Energy Technology Data Exchange (ETDEWEB)

Purpose: to evaluate the efficacy and advantages of the snare systems in the retrieval of foreign bodies from vascular system. Materials and methods: the snare technique has been used for intravascular foreign body retrieval. We performed percutaneous extraction of intravascular foreign bodies using combination multipurpose catheters and a nitinol snare loop. In this report, we evaluated the patients who had performed endovascular device reposition or foreign body retrieval from 1998 to 2001. Results: foreign body retrieval was performed in 15 patients. The foreign bodies consisted of seven fractured port catheters, one sheath fragment, one embolization coil, four wire fragments, one pace-maker transducer and one dislocated endovascular stent. In no case were surgical procedures required, and no complications were encountered. Conclusion: the snare technique is a useful and a safe method as an alternative procedure to surgery. This technique is highly effective ...

2004-03-01

14

Metallic implants and exposure to radiofrequency radiation  

International Nuclear Information System (INIS)

There is increasing use of radiofrequency radiation (RFR) in industry for communications, welding, security, radio, medicine, navigation etc. It has been recognised for some years that RFR may interact with cardiac pacemakers and steps have been taken to prevent this interference. It is less well recognised that other metallic implants may also act as antennas in an RFR field and possibly cause adverse health effects by heating local tissues. There are a large and increasing number of implants having metal components which may be found in RFR workers. These implants include artificial joints, rods and plates used in orthopaedics, rings in heart valves, wires in sutures, bionic ears, subcutaneous infusion systems and (external) transdermal drug delivery patches"1. The physician concerned with job placement of such persons requires information on the likelihood of an implant interacting with RFR so as to impair health. The following outlines the approach developed in ...

15

Digital luminescent radiography: A substitute for conventional chest radiography?  

International Nuclear Information System (INIS)

The image quality of digital luminescent radiography (DLR) is sufficient for routine biplane chest radiography and for follow-up studies of heart size, pulmonary congestion, coin lesions, infiltrations, atelectasis, pleural effusions, and mediastinal and hilar lymph node enlargement. Chest radiography in the intensive care unit may in most cases be performed using the DLR technique. there is no need for repeat shots because of incorrect exposure, and the position of catheters, tubes, pacemakers, drains and artificial heart valves, the mediastinum, and the retrocardiac areas of the left lung are more confidently assessed on the edge-enhanced DLR films than on conventional films. Nevertheless, DLR is somewhat inferior to conventional film-screen radiography of the chest as it can demonstrate or rule out subtle pulmonary interstitial disease less confidently. There is no reduction of radiation exposure of the chest in DLR compared with modern film-screen systems. As a ...